Loading...
HomeMy WebLinkAboutPermit M12-142 - TARGETTARGET 301 STRANDER BL EXPIRED 07 -07 -13 M12 -142 City oikukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 2623049005 301 STRANDER BL TUKW Project Name: TARGET Permit Number: M12 -142 Issue Date: 09/26/2012 Permit Expires On: 03/25/2013 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: Contractor TARGET CORPORATION T 0627 C/0 PROPERTY TAX/TPN 0950 , PO BOX 9456 55440 ALEX BURKHART 727 S KENYON ST , SEATTLE WA 98108 ALEXB @EVERGREENH VAC. C OM EVERGREEN REFRIGERATION LLC 727 S KENYON ST , SEATTLE WA 98108 License No: EVERGRL954R2 Phone: 206 763 -1744 X 247 Phone: 206 763 -1744 Expiration Date: 01/06/2014 DESCRIPTION OF WORK: INSTALLATION OF OWNER - PROVIDED EQUIPMENT: REPLACEMENT OF (17) ROOFTOP UNITS, TWO OF WHICH ARE BEING REPLACED BY (2) UNITS EACH FORA TOTAL OF (19) ROOFTOP UNITS. Value of Mechanical: $82,010.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $1,135.31 International Mechanical Code Edition: 2009 jjj: 1�/ \ Date: I d- W I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: 1 /2--c/Vz_ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -142 Printed: 09 -26 -2012 • PERMIT CONDITIONS Permit No. M12-142 1: ** *BUILDING DEPARTMENT CONDI'T'IONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this doc: IMC -4/10 M12 -142 Printed: 09 -26 -2012 project. • • 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M12-142 Printed: 09 -26 -2012 CITY OF TUKWS Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. A412-11-0- Date Application Accepted: Date Application Expires: o�ll�l�l3 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: 3 ° , "`1)" 1St \JJ Tenant Name: Itnek King Co Assessor's Tax No.: /C2301 -i 005 Suite Number: Floor: New Tenant: ❑ Yes ITNo PROPERTY OWNER , ,� Name: A6,.. R U I tY�a�''- Name: •T Carp (, 1 617 City: satAit State: kw Zip: twv( Address: p. 0, QaX pl 4 S 6 Email: al.PAt.beev e.4-4v41 vim(, - t ol,.N, City: /NihhP.cvl'lpf3 State: M, t Zip: SS�tip CONTACT PERSON - person receiving all project communication , ,� Name: A6,.. R U I tY�a�''- Address:-/ v_i 5, V � 5{._ , City: satAit State: kw Zip: twv( Phone: (,_ ?43- 1244 ,Fax: ?AG- 1‘- -z- s t Email: al.PAt.beev e.4-4v41 vim(, - t ol,.N, MECHANICAL CONTRACTOR QINFORMATION Company Name: r'�'" ° 4f2 1 Address: -7271 saw 1,<A,,,, w. Si- , C i t y : - State: t - Zip: Gt g I 0 ' Phone: IAA, -7 GI - I Z a q. Fax: 7/06-14-73- 2-3 $ `l Contr Reg No.: V 510_6_,g, La 54 pzExp Date: ` I G'14 Tukwila Business License No.: 13, l , D q etz9 77 Valuation of project (contractor's bid price): $ `�2 0 t 0 , 00 Describe the scope of work in detail: 1 �� IVbs //14.41 " t Owv -- p-tov: to G�Vt�jwa. �ccr+c.../� �'l.. !"tf✓1 1' tia1 ` p i'vv; A ' �h tom- , ►�,p /d b `two ���' ��vt+� ?ar !ti 4kil mS 1n:' �i -� (1 rztorlap Use: Residential: New ❑ Replacement Commercial: New Replacement Fuel Type: Electric ❑ Gas E,y Other: H:\Applications \Forms - Applications On Lme\2011 Applications\Mecbamcal Permit Application Revised 8- 9- 11.docx Revised: August 2011 bb Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu n C\ Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit n C\ >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature:! Date: A /Hi( 2 Print Name: 13 U Mailing Address: 12; 5wi-LN H:\Apphcations\Forms- Applications On Lute Applicattons\Mechamcal Permit Apphcation Revised 8- 9- 11.docx Revised: August 2011 bh Day Telephone: ' - li t - 2 7 City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2623049005 Address: 301 STRANDER BL TUKW Suite No: Applicant: TARGET RECEIPT Permit Number: M12 -142 Status: APPROVED Applied Date: 09/14/2012 Issue Date: Receipt No.: R12 -02705 Payment Amount: $908.25 Initials: WER Payment Date: 09/26/2012 01:11 PM User ID: 1655 Balance: $0.00 Payee: EVERGREEN REFRIGERATION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 005647 908.25 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 908.25 Total: $908.25 doc: Receiot -06 Printed: 09 -26 -2012 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2623049005 Address: 301 STRANDER BL TUICW Suite No: Applicant: TARGET RECEIPT Permit Number: M12 -142 Status: PENDING Applied Date: 09/14/2012 Issue Date: Receipt No.: R12 -02608 Payment Amount: $227.06 Initials: JEM Payment Date: 09/14/2012 11:33 AM User ID: 1165 Balance: $908.25 Payee: EVERGREEN REFRIGERATION, LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 005550 227.06 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 227.06 Total: $227.06 doc: Receiot -06 Printed: 09 -14 -2012 4- INSPECTION NO. INSPECTION RECORD, Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Z_ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: "7:47A 6-, f�,l�,_ rim '4A --;Ad - ilo94e P, ( ) ,5 tr,o k-, 4.5g a ri c/d a) ,4 r / j (/ ` t Type of Inspection: 4_:.s a Me $ i1, /i - .JOA/k/ Address: at /) /Z. fie y.®fn /.1.,,,✓ - 41/4 Date Called: Special Instructions: b V 9V /-Q / Date Wanted: / .Z — 0 — / Z:. ' p.m. Requester: Phone No: -,D 6 -G 7 Cr -3 17 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: �, • f�,l�,_ rim '4A --;Ad - ilo94e P, ( ) ,5 tr,o k-, 4.5g a ri c/d a) ,4 r / j (/ ` t r%%( (war-) 64'/ tr /Ua.t/S) " -e - AA,7 / ,t /F(✓4( / /),„ ,- -7/., /^/ at /) /Z. fie y.®fn /.1.,,,✓ - 41/4 Inspect Date: iz° i e ,R INSPECTION FEE REQUIREDIPrior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. -44- INSPECTION NO. INSPECTION RECORD Retain a copy with permit ,t4 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431 -3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project:- ----_, �-- 1 4J-6. - Type o�n p/v tion 1V Address t C-?\r Alg Date Called: ) Jej _skj l) J (-(i4 -ll -AI e_ct 1), ' Special Instructions: %Z .� l% (S j M ( r Date Wanted: (tO ' Z.4.. �.m; "' (� p.m. Requester: uf 1/ r---.2(--c Phan N 7 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ) Jej _skj l) J (-(i4 -ll -AI e_ct 1), -) r M t 04 ;'r 5 (. :: >' / Az_jUitf -P kl..t --t ---. ke `=So ut e LiG.c_/1 se,k eA,J i e a uf 1/ r---.2(--c 7 ,_ e In ctor Date; 0,:-2 - l l REINSPECTION FEE RE9I ED. Prior to next inspection. fee must be paid at 6300 Southcentyr Blvd., Suite 100. Call to schedule reinspection. 6 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 61/9 --149- PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: -1-74,[2-1e)(- Date: 1 /ilk 3 Type of Inpection: /t4 4 MUD Address: Suite #: 3U) ^��`� Contact Person: Special Instructions: Phone No.: pproved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Date: 1 /ilk 3 Sprinklers: Fire Alarm: '• -Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: (,A S - Date: 1 /ilk 3 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance"Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: \State: Zip: Word /Inspection Record Form.Doc T.F.D. Form F.P. 113 r INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit //a- /1/4,2— PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project_ � 7 Insp�tion: Type c, e Address: .? J _1, _ _ I Suite #: U 1 �a - 1V2-(111kf -6- Contact Person: Special Instructions: Phone No.: Approved per applicable codes. IACorrections required prior to approval. COMMENTS: Sprinklers: CI) Hood & Duct: FIA 0 CL /7 'bid Nut- Si.. Dow It) Permits: Occupancy Type: dl_ Ar b-e' s--- 6 Gov + { ' Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ✓j _5"`al- Date: / 2.151/ �/ z_ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc T.F.D. Form F.P. 113 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary MECH -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info FILECOPY mil N®. Project Address 301 Strander Blvd. Date 9/14/2012 Tukwila, WA 98188 For Building Dept. Use R Applicant Name: Evergreen Refrigeration Applicant Address: 727 S. Kenyon St. Seattle, WA 98108 Applicant Phone: 206- 763 - 1744x247 Project Briefly describe system type Description mechanical and features. Plans V11 Installation of nineteen (19) rooftop packaged units. SEP 14 2012 PERMIT CENTER Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Includes Compliance Option 0 Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu /h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N RTII -1A Lennox LGH036H4B 35800 240 17 N/A Econmizer N RTII -1B, 2A, 2B Lennox LGHO72H4B 73500 480 12 N/A Econmizer N DHII -3, 5, 11 Lennox LGH150S4B 144000 1875 10 . 8 N/A Econmizer N RTII -4, 6, 13, 15 Lennox LGH150S4B 144000 0 10 . 8 N/A Econmizer N RTII -7, 10, 12, 14 Lennox LCH15OS4B 144000 0 11 N/A Econmizer N RTII -8, 9 Lennox LCH120H4B 122000 0 12 . 2 N/A Econmizer N RTII -16 Lennox LCH15OS4B 144000 400 11 N/A Econmizer N RTII -18 Lennox LGH150S4B 144000 400 10 . 8 N/A Econmizer N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency° Heat Recovery Y/N RTII -1 Lennox L9103624B 52000 240 65000 52000 80 N RT17-1B, 2A, 2B LenuDx REVIEWED CODE COM FOR MA ME 52000 480 65000 52000 80 N DHII -3, 5, 11 Lennlx APPROs4B 144000 1875 180000 144000 80 N AM -4, 6, 13, 15 Lenn x SEP 2 4 1711..1 L ji2S4B 144000 0 180000 144000 80 N RTII -7, 10, 12, Lennl x TU LC`H15OS4B N/A N/A N/A N/A N/A N RTII-8, 9 City of LenaticBUILDING kWila b` isfON N/A N/A N/A N/A N/A N RTII -16 N/A N/A N/A N/A N/A N Lennow 'L'CHTS'084'B RTII -18 Lennox LGH150S4B 192000 400 240000 240000 80 N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM sp' HP /BHP Flow Controls Location of Service II 1 1 w 1 1 1 A 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential 11f available. 2 As tested according to Table 14 -1 A through 14 -1 G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary (back) MECH -SUM 2009 ashington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 System Description See Section 1421 for full description of P Simple System qualifications. All Systems: ✓ No humidification? ✓ No Reheat? If Heating/Cooling or Cooling Only(-noble ❑ Constant vol? ❑ Split system? ❑ <= 84,000 Btuh? ✓ Economizer included? ✓ c .ri ❑ Air rnnla ParkanPrl Svc? ❑cl3 nnn Rtuh? ❑ Cooling Cat) < =15 Btuh/ft2? ❑ Heating Cap. > 0 & < =10 Btuh/ft2? If Heating Only: ❑ <1nnn rim? ❑ <30% outside air? ❑ Heating Cap. < =10 Btuh/ft2? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ( START ) f12, or ft2? Yes Yes Heating/Cooling or Cooling Only Heating Only Reference Section 1421 Yes Yes Yes Yes Yes Yes- Yes Simple System Allowed (section 1420) • alifies Economizer Exception ion 1 Yes Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist MECH -CHK 2009 Wa";hington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address 301 Strander Blvd. 'Date 9/14/2012 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment Performance Yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M1 N.A. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss N.A. 1411.1 Air - cooled chiller Provide total air and water chiller capacity N.A. 1411.2.1 Water - cooled chiller Full -load and NPLV values adjusted for any non - standard conditions N.A. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule N.A. 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls N.A. 1412.1 Temperature zones Indicate locations on plans Yes 1412.2 Deadband control Indicate 5 degree deadband minimum M1 N.A. 1412.3 Humidity control Indicate humidistat Yes 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback M1 N.A. 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage N.A. 1412.4.2 Optimum Start Indicate optimum start controls N.A. 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule N.A. 1412.6 Combustion heating Indicate modulating or staged control Yes 1412.7 Balancing Indicate balancing features on plans M1 N.A. 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas N.A. 1412.9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. N.A. 1422 Thermostat interlock Indicate thermostat interlock on plans N.A. 1432.2.1 Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers N.A. 1412.1 Single zone systems Indicate multiple cooling stage control capability. Yes 1413.1 Air Econo Operation Indicate 100% capability on schedule M1 N.A. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb N.A. 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg load & equipment performance data. N.A. 1413.3 Integrated operation Indicate capability for partial cooling N.A. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting Systems N.A. 1414.1 Duct sealing Indicate duct design pressures, sealing, and testing requirements N.A. 1414.1.2 Low press. duct test Indicate applicable low pressure duct systems shall be leak tested N.A. 1414.1.3 High press. duct test Indicate high pressure duct systems shall be leak tested, and identify the location of this ductwork on plans N.A. 1414.2 Duct insulation Indicate R -value of insulation on duct 1415 Piping Systems N.A. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements Yes 1416.3.2 System Balancing Indicate air and water system balancing requirements M1 Yes 1416.3.3 Functional Testing Provide sequence of operations and test procedures. M1 Yea 1416.3.4 Documentation Indicate O &M manuals, record drawings, staff training M1 Yes 1416.3.5 Comm. Report Indicate requirements for final commissioning report M1 N.A. 1416.4 Compliance Chklist Submit to building official upon substantial completion. Yea Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist Continued MECH -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address 301 strander Blvd. (Date 9/14/2012 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. N.A. 1441 Elec. water heater Indicate R -10 insulation under tank N.A. 1442 Shut -off controls Indicate automatic shut -off of circulators or heat trace N.A. 1443 Pipe Insulation Indicate R -value of insulation on piping N.A. 1444 Pump Energy Indicate method of pump energy management (Sec 1438) N.A. 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. 1460 Heated Pools N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control N.A. 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R -12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction COLD STORAGE (Sections 1460 -1465) 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensors Indicate condenser cooling type, design wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. If "no" is indicated for any item in Sections 1401 -1424 or 1440 -1465 , provide explanation: k FILE C PY POrm!t 7 TARGET TUKWILA, WA REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 4 2012 City of Tukwila BUILDING DIVISION Cfl %S1A SEP 14 2012 PERMIT CENTER STRUCTURAL CALCULATIONS for Lennox RTU Replacement (Revised) T -0627 TARGET STORE 301 Strander Blvd Tukwila, WA 98188. Prepared for: �TAREET 1000 Nicollet Mall Minneapolis, Minnesota 55403 30 April 2012 Prepared by: ERICKSEN ROED & ASSOCIATES Consulting Engineers 2550 University Avenue, Suite 201 S Saint Paul, Minnesota 55114 651.251.7570 )627 Tukwila, WA 1.1* Moat 320 w Tye* 1. +30 m 13% Gat .» 4222 90 071212 1a1tl e0° RTU.16 0041, R-U -19 Harney 137 0.3 63 731 731 CM= =0749 5mrt1,3ou 063004737 On 3 11,1 136 .. 10031334. EZIMICIIIM21011111.1111111 0220 ®00740 007e144p0a 00 07410 1 1220 3025631443 , ;v 111=11® 37,7007103 134747-.747 6136. exiet SA Wee exln 0A n exist SA .222 74410A 1. Sales #27 52170 L1713t*4793 /es tonnage 163 3. Calc'tl new 3*3r.1010230 4) 20 00.6 /53 117 4,36 <et actual sales tonna,e 143 5, Sales 0.2 P 005.40/55 6574 6, E8429/1003 #4261 from 62#243-4 0726133332012.63731 7. Provide ad in•ta0 adaptor euebt tt and power eah,, t 3.11/61041 3as 0412 4011112 °ore 61.1 model numhece. 9 e nr 2512 0.25 and mmrcmrrer 11. New i0�(� �u-�wn[nn.«:tvde .•.:1 r.. a to 00 70040400 ,u *2.44.13201,402 re 4,n.: .x..047 1. tc.a.10, la,22 xrofar a 111,72 ter eM rcry tente.,.ox um (p) 030}3 123 rem (0) 011.1d 12.5 Use jTa) 05 22.5 004 (µ) 01124 22.5 Bee (0) R1U-7 123 no (M) R7U4 10.0 0. EMI RTU'S 103 sea (et) RTU-10 123 425 (M) 1361711 125 553 (M) RTL-12 123 53 EM) RTL -13 73.S 33 (M) RT11.14 12.5 404 (M) RT11.16 625 tae (M) RTL.15 125 17:0 1700 5,1.0 700 1700 0,511 en 1.025 Yee Len 0 s 0 50, Ott See note 7, 621311911, ERV See note 7 See note 7. 601347904, 0563 See note 7, feeling only See note 7, 00002505044) Sea Mt 7, M0n0611,W, ERV 1011570e solo AM 177 iv[ 0 See nate7 See nate 7. Co00n40nly 75.699 71130 St604 5.974 :3.73 014,519) 0463 el er. 977. of exist 501125) TarEe7 En0meerinp of any w,,.00: In conreured we1Lfd 253614306 set new adapiw rums on on 0100420 curbs er » dlroe3ed by 701 Lomtruction 40421972 Lennox 31140 cOwdMate 0400417 cett eon00uratlon with exist:, duel 24.1.771142# Lennox:hal veli1y exittinz acsee [onho641 d tie in new 625/245 required 23 Rtue /54 M) RTU.10 125 2061 EE) RTLS. 19 2.0 0144 101250 etd1. new Oa ,w tnew SA new 04 75,055 9265 57.370 6,615 Kean 0034044 06o,73Amz Canklu elmera mf 1060 931330 163100 001 800/36 0075 612757-5844 612 761 -6444 '10627 Tukwila. WA wa 7575 '2021 I7VAC Replacement Program Encineer/ne Review a7.777.011 51124 a ylfi,�j/2 R ap.1 3/10111 725251 1)817111 art7 aia 1;41600 wlenne. -.ee tebe lt,nued to:vmn WA013133 [arc. 0. Ia. :0 rat 4m:veeter Ono /win. Li."01r17-. 4605-66017111616616600 . • 0 0 . 0 . 0. 0 0 0 0 . 0 . • 0 • • 51 Of ' 10 40 . • 4 . • 4 3.• AN 40' .. . .6)-- . • 40 i ' 7 1 i Fr I . 40 I , U 40 ... .1..... II 0 0 , 0 i .- II r. N , . .. • . • ... 3 PP . IL ig .- _21-- X 'a - pi 14 11 _I ‘ willn.n. I . . . . Ilp • IFIM=pni 111%30 01.1111 t 40 il 41 . , la . • •@---hrs,„.4_ . . CI i t 0 r . • • it OD i K 0 :ii ..."-IIR M. t • I e 1 a a twillk 11 Rh _24 ' A 6.1 , : Rim 172 . 1 PI 1 .1 1 i. ri 0 ■-• op, . . sE. ,,,, Wk.. 4 &I rerliarallEgi ,...,. !ID U14.1.21 .. 4. i • '' _. . r.-■ .. FE4705'' 40 40 . l ToM,..1,._1 :r1 / 0 ,--S I> • - ... —.....— * .""..." — "" . k mew. ; v :.;.: A • 1 . . . . 2 • . . iz r . , . r : . i 1 E •; . . /s. . . - > 7 i g ii ' • ....-: • . . ." Si ,I9 inlif "Ji 0 7 ,,„-gi :a a 4 lEa q 1..4 n if ri'..i Ili 1; eigi 1.1... 0 .,• .. •1:. 1 eD — , ..• , '-' .. . .L..,... 'f.c . • • . • . . .. .. 0 1 r. , • . . • ... . .. - . 1,„„— QB ,...,. . • • ., . • . _ X .., et '‘t{ 4 • 4.1 •. `& 3 • . . --_-_N . _. • '› • • 1 i .... 40 . - '' ' .' 6 B IN& 11§ i .1 .' e. t . , Er T . . gAl • 11 k n ' 2 • in . • . • . • . . 40 i • • \ ' 4 40,i n 1 . I • 6 1 . Q . 0 „. . ' . 1 • : • . . V . . . . . .... S2 . . • ROOF FRAMING PLAN • • • ........ SOUTHCENTER .. P1-88 smut trAcm s urnmiec. wci. '7''''''''''''''''' • • * 0 TAHOET. ......1-......= , 1359 La ..... _ Ent 111 !0.1 g 5 r rt, 15 I I 6 rn g%g b 8 A 8 8 31f1a90S ISIOf 0 5 3 ; 3,A 0 r r " rilaull ii to s r' , • py i i ailli • 9* 17 Itt.i 104 UHL (,^ rd ' 14 I. Vi ja ;:, ;:.. qi; q TO 11 rill 1 I 5-i., iy AL., g . As N ii 1 1 .ii 1 .. li Itik' /;. P 1 r;:fr• 4 5 ill . b 1 • lo ? LH •red r. # pili ,...otil;iii; li,i 14 i3!,,,illi.j_iii ! A.zoi!,.5.._iiii iiiiiiiiiii, -.-1-41.-iiiiiiiii liiiii ..----1........— . gi 1 1 I. 16.4.,_ Wt.. ii..$ LI ;,','A210, k pa ti il :-.4,4 1 gl 1 TYisarglit AffhplA igsfAVOI il ;Ugill! tl 1131 IV iii$01 11 M. RI II 1/1. : gzi ka nT. 45111 !A :5 :.10 i Y', 11 ge .42 P14614i'At • g NAT mig, q qi, I/ ,.,, E. 2%3 V.1 1gi Om 1; P ;.# H 1.f ---:.A.. OMAN- 2 :1 Iii;: .b 3ki221. ! 3 1 • 11 10;*. 1 0/ I:I- 1 . pi 1! 1 ' Trill: Ng' Sem mppz Ei qi.R: h ..ir . - - -4 . 1,00 - tio SS I I VI 1. I. '0.14 Pi I . rt 1 ilit 'A p; I; 1 113ISV2 ii;3.5 0 IS .6144f' il 41: 5. 3 OP L 1 - 5 3.. - 33 .7 1. t - a 4g P! il PT ' & itt I: is !! 324 N. 'F: h — 1: . -.I ikeigh!i5 w i WA! 11 . 11Ni; 1 g &.i. '0, .1 ,s441pvie: in5 g all -.fioN4 gi i3r3 22RH2 ga 5?? 1 'TV.7:1"2:" -• • .1.1A i p A _ ; '.0 i .; . ; ; a,. N i; A 2= • ki 5 gil I I 1 140 : 4i fi d a Tigi 11 i: h g ii lil lqi 111 Egigg .,u,p i4 11 ih 5" 1r 3"333 IP !Hip= g pil ii A i 4 RE, A4 A",:g.g 9 3 a . ...4 t .A i• n P i a op r • No, ,... , . R.„ ,,. , g 7i. 5 IA F5. - --- p di r 7 IA p • ig a 3 II i A i 1 ul 2 3 PNV 4; 4 "; iii1"211 Iii 1 p 11 1 A 're- ••••• • II I A x fh 0 g1f/All 1.1j ° 1 5 •P 1 1 ;: 1 lil 130 PACKAGE 3.0 rway.sure 071117.100INCOPOMMAID UMW= AlliM011.03SUDDIMOUCEI S4 GENERAL NOTES, SCHEDULES, & DETAILS SOUTHCENTER 341.4.41 PI-88 1.17011118, oarso.ors man. apromanv rATtr....F • tad mac. oce. Pea •••■1.4 100101. 11,1 tid A WWII.. :Al aYt s r' , • py Dio, 9* 17 Itt.i oarso.ors man. apromanv rATtr....F • tad mac. oce. Pea •••■1.4 100101. Crafltegy Kw, qaAccIA ,rsee /400a, r. -em m. •+•orrrr o`nr}_._ • WIresi ' .N �,1 i e •,, +44 rsv/ G„+02 rue, 4•71> /tiff adr i:::::'S -.ro-r a 3 4f •h- --- '- ' -' -'r i 4 17141 • Dirt T •'-- 'Tiv/t -m 0 u .�i— �xrr.r 11 —tr19e S -�'•y� I 4 ,. rz f I IF —C-71 I t ROOF FUN >.r ■na a • w a 4, rrr.ar.,a AMC 0 I. SR WO11017M,V4 Va:12:1 if I. sUnerna. Ann ID AKANSILILY 11.40. MCA /NO 577L4 Par mart r<r m32. rrrrrrr,10. 1 as z 0 0 SEISMIC DESIGN 2006 IBC - ASCE 7 -05 SEISMIC LOAD SUMMARY SEISMIC PARAMETERS Eh (Base Sllear)= E„ = Diaphragm = Wall Design = Parapet Design = Mech Equip = Wall Anchorage = (Min) Wall Anchorage = 0.271 w +/- 0.19D 0.190 w 0.379 w 0.455 w 0.455 w 0.759 w 379 p1f Seismic Design Category = D Soil Site Class = D Seismic Use Group = I J013: COMM #: DATE: NAME : Tukwila, WA 6/24/2011 BEN Ss = 1.423 SDS = 0.949 S1= 0.487 SDI = 0.491 R= 3.5 Ip = 1.00 Ie = 1.00 Spectral Response Acceleration Parameters (ASCE 7 -05 611.4.3) Ss = 1.423 SI =' 0.487 Soil Site Class = D 0 Design Spectral Acceleration Parameters (ASCE 7 -05 01.4.4) Building Catcgory = 11 Scismic Use Group = I Fa= 1.00 F„= 1.51 (11.4 -1) SMS = 1.423 (11.4 -2) SMi = 0.73683 Seismic Design Category = D (11.4 -3) SDS = 0.949 (11.4 -4) SDI = 0.491 Equivalent Lateral Force Procedure (ASCE 7 -05 412.8) R = 3.5 Cr= hN 21.3 ft p =i 1.0 IB = 1.00 Eh= 0.271W = +/ -0.19D Nonstructural Components (ASCE 7 -05 ch 13) Parapets Tp = 1.0 Rp =j2.5 z= ,21.3 ft h= 121.3 ft ap = 1.0 Ct= 0.020,x =0.75 All Other SLOGS I v Structural Walls (ASCE 7 -05 612.11) Fp (used) = 0.38 W (12.11.1) Fp(mla)= 0.10 W (12.11.1) Fp= 0.379 W Diaphragms (ASCE 7 -05 612.10.1.1) Fp (used) = 0.190 W Fp = 0.190 W Base Shear (V) = 0.271 W Cs (used) = 0.271 (12.8 -2) Cs= 0.271 (12.8 -5) Cs (min) = 0.010 (12.8 -3) Cs(max)= 0.707 (12.8 -7) T = 0.199 Fp(usea)= 0.455 W (13.3 -3) Fp (mm) = 0.285 W (13.3 -2) Fp (max) = 1.518 W (13.3 -1) Fp= 0.455 W Mech Equipment Ip= 1.0 Itp =,2.5 z= ;21.3 ft h = f21.3 ft ap ='1.0 1Lat 47.45685 Long - 122.25838 Fp (used) = 0.455 W (13.3 -3) Fp (N) = 0.285 W (13.3 -2) Fp (msx) = 1.518 W (13.3 -1) Fp= 0.455 W Wall Anchorage (ASCE 7 -05 &12.11.1) Fp (used) = 0.759 W (12.11.1) Fp (min])= 0.38 W (12.11 -1) Fp (min2) = 0.759 W (12.11.2 -b) Fp(min3)= 379 plf DESIGN ROOF LOADS PROJECT: T -627 CITY, ST: Tukwilla, WA ENG'R: BEN DATE: 6/24/2011 ROOF DEAD LOADS (PSF) - Roof membrane - Insulation - Hail Protection Board - Future DL Allowance - Roof deck - Joists - Ceiling - Lights - Electrical - Mechanical - Joist Girders Roof Deck Roof Joists Girders /Cols 0.36 0.36 0.36 0.66 0.66 0.66 1.10 1.10 1.10 1.46 1.46 1.46 2.17 2.17 2.17 2.80 2.80 0.97 0.97 0.36 0.36 0.50 0.50 1.00 1.00 0.68 5.75 11.38 12.06 - Sarnafil S327 PVC, 0.048 mil - Assume 4" : Polyiso = 2.0 pcf - 1/4" dens -deck - Re- roofing (1/4" dens -deck + Roof Membrane) - 1 1/2" 20 Gage Type 8 + sidelaps - 241-18 = 13.5pIf @ 4' -10" spacing - ACT -1 Armstrong + Prelude XL Tee Grid System - Al: 3 Lamp Lithonia Proto Proto - 40G @ 44' PSF Owner Required Roof Design Load Increase at 5.00 PSF Joist pif spacing psf 24H8 13.5 4.83 2.80 ROOF LIVE LOADS (PSF) - 1607.11.2.1 JG pif spacing psf 40G 30.0 44.00 0.68 Trib Area 400 ftA2 R1 0 -200 ft2 201 -599 SF >600 SF 1 1.2- 0.001AT 0.6 Roof Slope 1/8 in /ft 0 -4 in /ft 4.1 -11.9 in /f >12 in /ft R2 1 1.19 0.6 Live Load, Lr = 20R1R2 20 DESIGN LOADS 16 12 psf > Use R1 = 0.8 > Use R2 = 1 - Ground Snow Load - Roof Snow Load - Roof Live Load - Basic Wind Speed - Wind exposure Category - Seismic Design Category Zone 3 - Site Class - Seismic Coefficients - Allowable Soil Bearing Pressure 2500 psf Original Design Code :Current Design Code: 1998 UBC WSBC (2009 IBC) 20 psf 30.0 psf 20.0 psf 20 psf (Reducible) 27 psf 85 mph B D Ss= 1.423, S1 =.487 2500 psf Based on Original Drawings prepared by Target dated: 29- Jun -89 Code used in Analysis of existing members: IBC Eiricksen oed & Associates Structural Engineers Saint Paul Office 2550 University Avenue West, Ste. 201 -S Saint Paul, Minnesota 55114 -1904 Telephone: 651- 251 -7570 Facsimile: 651- 251 -7578 C�Rrtb �-I1-f Eau Claire Office 3610 Oakwood Hills Parkway, Ste. #1 Eau Claire, Wisconsin 54701 Telephone: 715 -552 -5336 Facsimile: 715 -552 -5373 pL.tn, ► •r {(4es) sV 6 (IrbS) o \" rE,1 o t,-'I it T. 14)13)1' 4) 13 )1' IA./ - ,i01/104. (6 CL:, (,V) ed A /Fi {- Page No - Job l L 11. �L l.t} l• I �(a t ��i� Comm. No. Date Name /44-s1444- re- 1 q? itylk >4, - ,\J v-er tz1-7t Fonbx _ (u (b) k- t4-5 114 12/‘FYIA (..,c/E)) )C tiqqb 1- S S O V ' (1.7,—*5; fI A,17 --e) ,6014(-7 /- o,'i1' C I . ova ;.„(C (6,0v2.4-6•1 q/r1-111,1 Fr�J "JOIST.xls" Program Version 1.6 GENERAL STANDARD JOIST ANALYSIS For Steel Joists Considered as Simple -Span Beams Subjected to Non - Standard Loads Job Name: T -627 Tukwila, WA Subject: (E) 28H8 w/ (N) RTU 3 -14 Job Number: Originator: I Checker: Input Data: Joist Data: Designation = Span, L = Modulus, E = Inertia, Ix = H- series 44.0000 29000000 526.40 ft. psi in. ^4 Original Design or Capacity Loads: Full Uniform: w= Distributed: #1: #2: #3: #4: #5: #6: #7: #8: Moments: #1: #2: #3: #4: 291 plf Start End b (ft.) Wb (plf) e (ft.) We (plf) C (ft.) M (ft -Ibs) New Design Loads: Full Uniform: W= Distributed: #1: #2: #3: #4: #5: #6: #7: #8: Moments: #1: #2: #3: #4: 203.7 plf Start End b (ft.) wb (plf) e (ft.) we (plf) C (ft.) M (ft-lbs) a +p +wb EffillITIENIENTEMENtiff RL x RR Nomenclature Point Loads: #1: #2: #3: #4: #5: #6: #7: #8: #9: #10: #11: #12: #13: #14: #15: Point Loads: #1: #2: #3: #4: #5: #6: #7: #8: #9: #10: #11: #12: #13: #14: #15: a (ft.) P (lbs.) a (ft.) P (Ibs.) 18.4200 26.4200 1130 1130 +w 1 of 3 6/24/2011 1:02 PM "JOIST.xls" Program Version 1.6 Results of Joist Analysis: Original Design or Capacity Loads: End Reactions: RL = 6402.0 lbs. RR = Minimum Desi • n Web Member Shear: Vw(min) = 3201 Maximum Moments: +Mx(max) = - Mx(max) = 70422.0 0.0 6402.0 lbs. lbs. (50% of maximum end reaction for H- series joists per SJI Spec's.) ft-lbs ft -Ibs @x= @x= 22.00 0.00 ft. ft. *Maximum Deflections: - 0(max) = -1.849 in. @ x = 22.00 ft. +A(max) = 0.000 In. @ x = 0.00 ft. 0(ratio) = L/286 *Note: deflectbns shown above include a 15% increase above the values calculated using traditional "simple- beam" flexure in order to more closely match actual test results obtained by SJI. New Design Loads: End Reactions: RL = 5589.8 Maximum Moments: +Mx(max) = - Mx(max) = 69636.5 0.0 Ibs. RR = 5633.0 lbs. ft-lbs @ x = 21.89 ft. ft-lbs @ X = 0.00 ft. *Maximum Deflections: - L(max) _ -1.792 In. @ x = 22.02 ft. +A(max) = 0.000 in. @ x = 0.00 ft. Lt(ratio) = L/295 *Note: deflectbns shown above include a 15% increase above the values calculated using traditional "simple- beam" flexure in order to more closely match actual test results obtained by SJI. Maximum Stress Ratios: S.R. = S.R. = Comments: 1.046 0.999 for Shear for Moment 33.44 26.40 ft. ft. 2 of 3 6/24/2011 1:02 PM 50GT.xlePnogram Version 1.6 8000.0— r-■ —rr—' 6000.0 4000.0 2000.0 • 0.0 co -2000.0 .. ... '''''' • . ... . . -;' _ l` . ' • I`i ' . . .<�. Shear Diagram ' . ''''' ''''' ' ..... . ...... . ../../� ...... 1 11111 ....... • . 1•114114 .. .. .. . / ...... .. /. .'. . .... .. .. .... . . . .. . . . . . . .. . . . /..... . . .. ... .. ... 111111 '� 1.4....1.111' � | / | .. .. ./� ... 1.1 • . .. . . .. , .. . .. . • • ^� . . .. .. .. . . .. .. . . . .. .. . . . .. . • • .. .. .. .. . . . If .. . . . . . .. 4. . . . ... .. I •. .. . . . .. . ' .. 1 ./ •. /.. ..� . .. ... .. . || | | ... .. |�| || . . . /. ...... -4000.0 - -8000.0 - .. . ..'... =7:| | |� �.� • ui cd.� ... . �. ..r ... � �|0 � m'� � �� ... 0|w 03.C•I . '. . . . . . . . '. . ... . • .�� � .�| | • | • Csi|�| ��""|�|��|�.�� . / /. 1/ �. .. . .. • I ..' ... .. , .. 11114 . . .. . .• ... . ... .. .. . . . • . 1,1 .. .. 4,1 . . . . 111 ./ ..1' 1' ' . . . . . . . . ^ • . • • ... . ... . ... ...../ . ..� . /.. .. . .. .... .. . .. . . . .�...... /. /•. .. ./ . / .• . .. ■ . . .. .. ..... ... !''||. '|� !| �� � |• |'| 00000.0' 70000.0 - 60000.0 - 50000.0 - sa 40000.0 • 30000.0 ' • 20000.0 10000.0 0.0 ..4 •.• t'..: .� .' • . . .. .. .. . . . 4 . 1 1 . � . . . . .. • 4 • . . • � .... .. . . . 1 . . . . . . ~ . • . • . / . • | 1 1 | | 1 | | | • | | | � • • . . / . . / / . ; / • • / 1�^. . . . 1 . . . • . . 1 ' . • ,^^ .7 ./. I . • .•/../ . / ,/ . . 14 I . / • . / . ./ • • / . . ...... . . . . 4 4•:1: 1 .. .. .. . . . . . . . • . . • .. .. . 14 1 . . /. . / • / . .. . . x (ft.) Moment Diagram . . . . . . ... ... � . .. .... .. .. . .. .. • 111 1'1 . • . . . . • . :. .. ./ . . . . .. .. .. .. . . . . . . . • • . . 1.1 . .. . . . . . .. .. . . .1 I' . . . .. . . . ` . . � .. . . .. . .... . •• . . . ... ~' . . `' / . .. . .. /. . I, . � .. / . . • . . . . . / . . . . . . . / ^ ' . . • . .. / .. // ,1,/. .. / . . / . 14 • .•• . . . • // . . . 11 `^. . . . .. 1•I .. 11.1 .. . .•° / . . .. .. '4 ^� / . '. . / .. 11 / .. '. .` // 1 . . •.. .�. • ` ... . .• . .. . . ... . . . , . / . . • . . • . . . . • ' ../ .' .�/ .. .. . • . . . . . • � . . • . • • 1 • �-' 1 . .�.'` . / 1 . . . ... • . . . . .� • . . . . . . • . . / � , ., ' ... . .•. ...... . ... |•| ... • • . � . � | | | | �� | . | �| | || | . ... � . ... . 1 • ' '' • | '| �' ' 11,1 . . . .• . . . / . ;414,, .4l!',| '~ ; • . . . ... 1 • • .... ... .... ... .. • .. • . • .. ,~ .. 1 1� .. .. .. `~ .. )s111 • � cp 3 . � | / ' ' • .. .. .. • /. 1 . .. .. . ' ... .. •. .. . /' .. ... ^. ... .. .` •••�-� I• || • '^ • || 1 .. . . � ` . . . . .. . . .. 1 . .. .`. . |/ . .. ./ . .�. / .; .. .. . . `. .. .` .... . ...,.. .` 11 . . • . . �. 1411 -�|-.- .,!'| .. . 1 .' . .. . .. .. . 1 . 1 ./ ;I 1; | | | | | | | | | i i ! | | | ! | | | | 1 ! } / { | | ||| | | | / | | , ,C0|�|�|�'X| |�| � �C ' | |�| | 1 4O�0��''�|�L�-|�-����'���|����m� �.�|���'|�.c�����~�—|�������,�,' x (ft.) = curves for original design or capacity Ioads - curves for new design loads 3 of 3 6/24/2011 1:O2PM ckseri oed & Associates Structural Engineers Saint Paul Office 2550 University Avenue West, Ste. 201 -S Saint Paul, Minnesota 55114 -1904 Telephone: 651 -251 -7570 Facsimile: 651 -251 -7578 Eau Claire Office 3610 Oakwood Hills Parkway, Ste. #1 Eau Claire, Wisconsin 54701 . Telephone: 715 -552 -5336 Facsimile: 715 -552 -5373 a-r"s, (REetAtc6,44.t.'r of £xts -nn16— it-t.) UPRNGsGS� Page No Job b(.? 1' TOICW∎l wA Comm. No. — tt5'Z(o - 0 0 Date /4/30112- Name RT V1- 1 it-r0 - Z , t 9-1'0 -- 11- k061e. a"' R> o ✓ED 0611-- 71fe, Sap. oP 711;5 7i?oJEcr,, Mut 1 EI,Q CALLvc owls 44104_ p>u Deb.' Wcwp£6 (An 7111^1 mi:, C4LCvti4T1ON PACT GE- "JOIST.xls" Program Version 1.6 Job Name: T -627 Tukwila, Job Number: GENERAL STANDARD JOIST ANALYSIS For Steel Joists Considered as Simple -Span Beams Subjected to Non- Standard Loads WA (E) 28H9 w/ (N) RTU 15, MI I 1 Checker: 1 Subject: Originator: Input Data: Joist Data: Designation = Span, L = Modulus, E = Inertia, Ix = K- series 44.0000 29000000 526.40 ft. psi in. "4 Original Design or Capacity Loads: Full Uniform: w= Distributed: #1: #2: #3: #4: #5: #6: #7: #8: Moments: #1: #2: #3: #4: 327 pif Start End b (ft.) Wb (pif) e (ft.) we (pif) C (ft.) M (ft-Ibs) New Design Loads: Full Uniform: w= Distributed: #1: #2: #3: #4: #5: #6: #7: #8: Moments: #1: #2: #3: #4: 204 pif Start End b (ft.) Wb (pit) e (ft.) we (plf) c (ft.) M (ft-Ibs) a +p +wb 0011111111 IIIITHERESSIEETEMIll we RL x RR Nomenclature Point Loads: #1: #2: #3: #4: #5: #6: #7: #8: #9: #10: #11: #12: #13: #14: #15: Point Loads: #1: #2: #3: #4: #5: #6: #7: #8: #9: #10: #11: #12: #13: #14: #15: a (ft.) P (Ibs.) a (ft.) P (Ibs.) 2.4200 10.4200 865 602 +w 1 of 3 6/27/2011 9:36 AM "JOIST.xls" Program Version 1.6 Results of Joist Analysis: Original Design or Capacity Loads: End Reactions: RL = 7194.0 lbs. RR = Minimum Design Web Member Shear: 7194.0 lbs. Vw(min) = 1798.5 lbs. (25% of maximum end reaction for K- series and LH- series joists per SJI Spec's.) Maximum Moments: +Mx(max) _ - Mx(max) = 79134.0 0.0 *Maximum Deflections: - L(max) = +Q(max) = 1\(ratio) = -2.077 0.000 L/254u ft-lbs ft-lbs in. in. @X= @X= @X= @X= 22.00 0.00 22.00 ft. ft. ft. ft. *Note: deflections shown above include a 15% increase above the values calculated using traditional "simple- beam" flexure in order to more closely match actual test results obtained by SJI. New Design Loads: End Reactions: RL = 5764.9 1 Maximum Moments: +Mx(max) = - MX(max) _ 53639.7 - 0.0 lbs. RR =I 4678.1 'lbs. ft-lbs @ x = 21.07 ft. ft-lbs @ x = 0.00 ft. *Maximum Deflections: - Amax) = -1.420 in. @ x = 21.7_6 ft. +A(max) = 0.000__ _ in. @ x = 0.00 ft. A(ratio) = L/372 *Note: deflections shown above include a 15% increase above the values calculated using traditional "simple-beam" flexure in order to more closely match actual test results obtained by SJI. Maximum Stress Ratios: S.R. = S.R. = Comments: 0.817 0.809 for Shear for Moment 1.76 w. 1.76 ft. ft. 2 of 3 6/27/2011 9:36 AM "JOIST.xls11 Program Version 1.6 8000.0 - 6000.0 - 4000.0 - 2000.0 - cn L • 0.0 4) G t � - 2000.0 - Moment (ft-Ibs.) 1 1 1 • 1 1 1 1 1 1 . 1 • r • .•1•1 1 I , T - I 1 • to 11 1 1 `A i Shear Diagram 1 1 1 • 1 ' 1 ' 1 1 11 t I I I 11..11 1 11 1 1 , I I I'' I I 1 1 1 I i I 1 f I r•� t I 1 1 1 1 1 1 1. If 11 • • 1 1 I I I 1 I 1 1 1 1 1. 1 1 1 1 1 I I 1 1 t1 1 1 1 1 1 1 1 1 i 1 to (y Q ' I M IQ h • 1 I I - 4000.0 - - 6000.0 - - 1 1 • I 1 I - 8000.0 - - - - -1 90000.0 80000.0 - -• 1 ' 1 1 70000.0 , • 1 1 . f I I 1 1 1 1 1 1 01 03 1 I M (0 1 O I (V t r I :.1 1 _ • I 1 1 I • 1 1 1 I 1 • 1 60000.0 50000.0 - i • - • - i - I •I • 1 ,' I 40000.0 30000.0 20000.0 10000.0 0.0 - 10000.0 1 1 1 1 1 1 ' N co I d' ' O r-.- M I 3. • 1 r x (ft.) Moment Diagram r • • • �1 • � • , • • • • 1 1 • 1 • 1 1 1 1 1 1. 1; • 1 1 1 • 111. ., 1, 1 1 1 1 1 1• t t 1 1 1 1 -I- -'1 - ''1-•I I- , I 1 1 1 1 r 1 1 1 1 1 1 1 1 1 1 1 • 1 • 1 •1 1 t I 1 • • I 1 1 1 1 I 1. 1 . 1 1 I 1 1 • 1 I 1 11 1 1 1 I r 1 I I • 1 1• 1, • 1 •1 1 1 1 1 1 1 1 1 1 I It' 1 • • 1 t 1 • , 1 1 , •1 1 1 I I 1 1 1 ' • 1 I f0 ' N ' co ' 'd' O ' (o ' N ' co ' O ' (o N ' ' a} 1 a ' (b N ' Ob 1 ' d ' (O ' fV 100 ' h 1 (() N 1 0 1 co l) 1 M I O 1 (0 1 (,') 1 7 1 co I coo 1' 3' 1 W 0) 1 ((4 • N • C) 1 'd' 1 N 1 O e- I (vi 1 N 1 • c d 1 6 1 (V I a l td 1 r 1 of I ' fV 1 d: ' (o I eb 1 W 1 1 (h I I.A I ( G I Ob 1 0 1 (( x (ft.) - - - = curves for original design or capacity loads = curves for new design Toads 3 of 3 6/27/2011 9:36 AM EILAicksetrl oeci & Associates Structural Engineers Saint Paul Office 2550 University Avenue West, Ste. 201 -S Saint Paul, Minnesota 55114 -1904 Telephone: 651 -251 -7570 Facsimile: 651- 251 -7578 Eau Claire Office 3610 Oakwood Hills Parkway, Ste. k1 Eau Claire, Wisconsin 54701 Telephone: 715 -552 -5336 Facsimile: 715 -552 -5373 l e l-1 7;, VJ 7- 2? VII t�(L iii-ttoq ( /01, 44 -sirj .] '365_0 41 / ora, 7 6-17- 172 rgxt,epi7n 1 i1 Page No Job • 1---(r 117 • Comm. No Date (l?ll Name (3r j Y /1193 1r "JOIST.xls" Program Version 1.6 GENERAL STANDARD JOIST ANALYSIS For Steel Joists Considered as Simple -Span Beams Subjected to Non - Standard Loads Job Name: T -627 Tukwila, WA Subject: (E) 22H8 w/ (N) RTU 18 Job Number: Originator: Checker: 1 Input Data: Joist Data: Designation = Span, L = Modulus, E = Inertia, Ix = K- series 44.0000 29000000 526.40 ft. psi in ^4 Original Design or Capacity Loads: Full Uniform: w= Distributed: #1: #2: #3: #4: #5: #6: #7: #8: Moments: #1: #2: #3: #4: 225 plf Start End b (ft.) wb (gift e (ft.) we (Of) c (ft.) M (ft -Ibs) New Design Loads: Full Uniform: w= Distributed: #1: #2: #3: #4: #5: #6: #7: #8: Moments: #1: #2: #3: #4: 203.7 plf Start End b (ft.) wb (plf) e (ft.) We (plf) c (ft.) M (ft-Ibs) RL a +p +wb ovoid° EllitERTE MERMITH1 Nomenclature Point Loads: #1: #2: #3: #4: #5: #6: #7: #8: #9: #10: #11: #12: #13: #14: #15: Point Loads: #1: #2: #3: #4: #5: #6: #7: #8: #9: #10: #11: #12: #13: #14: #15: we RR a (ft.) P (Ibs.) a (ft.) P (Ibs.) 10.0000 18.0000 585 585 +w 1 of 3 6/27/2011 9:59 AM "JOIST.xls" Program Version 1.6 Results of Joist Analysis: Original Design or Capacity Loads: End Reactions: RL = 4950.0 lbs. RR = Minimum Design Web Member Shear: 4950.0 lbs. Vw(min) = 1237.5 lbs. (25% of maximum end reaction for K- series and LH- series joists per SJI Spec's.) Maximum Moments: + Mx(max) _ - Mx(max) = 54450.0 0.0 ft-Ibs ft-Ibs @X= @X= 22.00 0.00 ft. ft. *Maximum Deflections: - A(max) = -1.429 in. @ x = _ 22.00 ft. +A(max) = 0.000 in. @ x = 0.00 ft. A(ratio) = U369 *Note: deflections shown above include a 15% increase above the values calculated using traditional "simple- beam" flexure in order to more closely match actual test results obtained by SJI. New Design Loads: End Reactions: RL = 5279.1 Ibs. RR = 4853.7 Ibs. Maximum Moments: +Mx(max) = ft -Ibs @ X = 20.17 ft. - Mx(max) = 57825.6 0.0 ft-Ibs @ X = 0.00 ft. *Maximum Deflections: -A(max) = -1.509 in. @ x = 21.74 ft. +A(max) = 0.000 In. @ x = 0.00 ft. A(ratio) = _ L/350 *Note: deflections shown above include a 15% increase above the values calculated using traditional "simple- beam" flexure in order to more closely match actual test results obtained by SJI. Maximum Stress Ratios: S.R. = S.R. = Comments: 1.193 1.112 for Shear for Moment @X= @x= 9.68 9.68 ft. ft. 2 of 3 6/27/2011 9:59 AM "JOIST.xls" Program Version 1.6 6000.0 4000.0 2000.0 Shear Diagram •1 1 I I — 4 -1 1 11 1 1 I, 1 1 1 1 1 I 1 1•• 1 t I 1 1 • I I • 1 1 1 1 I I I I• I I I• I it 11 • 1 1 •I • I I I 1• 1 I t l I •, I • 11 1 • I , 1 1 1 1• i 1 1 1 1 1 1 1 I I I I 11 1 I I• I I I I . 1 1 1 I •1 1• t • • I I• t! • 1 • 1 , •, 1 I I 11 1 1 I! I 11 I I f• I• 1 I I 1 I 1 1• 1 1, • 1 1 1 r l 1 11 • I f 1 + 1 1 1• 1 1 Is i (•• I 1 1 1 1 1 i t I, L 0.0 CO 1 CO CN • CO * I O I CO ' CV ' CO O 1 CO ' CO t ' O CO N ._ .. I I� IQ N 4, co 1 IA • co I G co • co 1 �? 1 r I . • , CO 1 t- O) y 1 : CI) I ) I� co • O 1 N 1 d' In . Ih • a) N ; 1 (O co O) • I I I I 7 1 7 I • r N, (V N N N til 1 1 • I •I I l l s I• I Moment (ft -Ibs.) -2000.0 - _I_ _ _ _ _ 1 I 11 r l, I 1 I 1 I I - 4000.0 - 6000.0 1 t I t , 1 t t II • 3 1 N 1 rn• R ri M 1 M ; M M I I 1 1 • *a• 11. a ,Na. • 1 1 • • I 1 70000.0 60000.0 50000.0 40000.0 30000.0 20000.0 10000.0 0.0 - 10000.0 1 — 1 x (ft.) . 1 • 1 1 • • 1 I 1 Moment Diagram 1 • CO I N CO O ' U) • N ' ob - 1 0 ` Cb I CV I cb ' � ' d 1 CO ' CV ' ob • d ' 0) I N cb ' C 1 ' O I in . N • 1 co 1 II) 1 (") I O co • CO 1 M I r CO ' CO • V- • e;• a) CO • N I 0) 1 N. • V • N O r. I Cvj I L•) I co • p 1 nj ' • ICl 1 n , a) 1 • CV 1 • CJ ob ' a) 1 a+ I M Cn ' (o • co • 0 ' N �• . I 1 • f I r <- 1 ,- 1 r N • N 1 • 1 N I N N• N I CO • CO I CO • CO I CO • T I d• • 'Cr — = curves for original design or capacity loads x (ft.) - curves for new design loads 3 of 3 6/27/2011 9:59 AM TARGIET. Remodel - Structural Engineering Calculations PROJECtt Target CITY si: Caterers Stores euaM nah DATE: 12/1612009 RTU Supports See Plan for locations & weights ' SEISMIC PARAMETERS , NONSTRUCTURAL COMPONENTS -ASCE 745, Section 13,5 13.3,1 Pp :2 (0:40 ep SosWp) (1 +2zlh)1(Rdlp) (Eq. 13,34) Fp (max) =1.0%0pp (Eq,132- 2)12.74B Fp (min).= 0.3SoslpWp (Eq.133 3) '0.515 Srm= tjut;;: '!f ` Component Amplification Fader, ep.;:r •••,;;;y` (Tebfe13,6 -1). componeajRespcnse Mod. Factor, Fj,& '' yii,,,`• :i; :6;•' .J r1(Tebte 13,8 -1) Component Importance Factor, re -' t14 ,..,'4e.,.1(13.1.3) Avetage Roof Height, h e i;;tj ' 4 ,2G�1 },',.1 }y',ff. Helghtof Component Attach menl;x = +r'�;�; • {25,04'; #•S4c !ift 1+ fit= :'!jirL%3 +e�:..i.i (3 max per 13,31) FA =;',i�,'.i;Q e2 t:' ] x WIY (Wp = Weight of Component) WIND LOADS, ASCE 745, CHAPTER 6 BASIC WIND SPEED :V = EXPOSURE CATEGORY: IMPORTANCE FACTOR: I o Wind • 0.5.15.1 Kr lCat Kd qt• O Cf Af . �.a ') `mph Pluto 6-1) ;' 1"r a (65.a) 14 e :Lli:!' 1 (Table 6-1) g, =0.002.)- 64K1i11 = q GCri1t re 17. 4:1 ttfpsf girfii WOO Equipment for Buldrngs, 6.5.15.1 Af ee0.1S3h psf psr m=1.3 q q for Stress Incr ENCLOSED STRUCTUREpet e,2 rr. �. �r, z, height r• : : ti,;,;,r.?„t:red TABLES 0.2, 6-3 a ra z Ks B 7 1200 25 0.700591125 C 9,5 90Q 25 0.45264869 0 11,5 700 25 1.126942988 Uplift on UnIt - Use Flat Roof UplIft(Far from Edge) q dr,;4 }7 P.0 q for Stress fear r'.,: a' lililr psi co =1.3 OVERTURIJINGt CALCULAifICNS RTU Name Platform Haight • ft Unit Hoight Width. Depth ft ft t Weight Joist Span i onno, R wl Hord Wheel 0.07 (_ _.` 'i.r" T i:..� ( , •_;.,.. ._; L r.,) • '.;11'5);_ 1 s ►;��'• `_ _ii, �- RTU Name klai ITDI ; Eh (11) ifpw,..' -J min, Weight Max. Weight +0.70a (1.0 +0:14Sbe)1S+0•70 Wilt (ft) Dowry/ Sf)ear ' FV (0.6.0.14Sos)D (0) OT Mom (541) Lennox RTtl wJ HeatWheel 3171 1321 • -172$ -225 _ _ =1:I4'::' . 1I.. ,.3/',1!'.„, 0 L.-- ' ° .:-� o 0 0 RTU Name ? Min, Weight ti i{ZtrIC f 1 Max:Weldht 1.004-w (No Uplift) U • Ilff 0) Down (.1i) Shear (11) F 0.6D +W (Uplift) ( #j (0) OT Mom (54) Lennox RTU wl HeetWheei 1851 .1420 -2681 4,i.,', 2700 1081 0 0 0 ' • 0 0�_ Seismic Design Category D Conterminous 48 States 2006 International Building Code Latitude = 34.1095 Longitude =- 117.7597 Spectral Response Accelerations Ss and Si Ss and SI = Mapped Spectral Acceleration Values Site Class B - Fa =1.0 At =1.0 Data are based on a 0.009999999776482582 deg grid spacing Period Sa (sec) (g) 0.2 2.574 (Ss, Site Class B) 1.0 0.976 (S1, Site Class B) Conterminous 48 States 2006 International Building Code Latitude = 34.1095 Longitude = - 117.7597 Spectral Response Accelerations SMs and SM1 SMs =FaxSs and SM1 =FvxS1 Site Class D - Fa = 1.0,Fv =1.5 Period Sa (sec) (g) 0.2 2.574 (SMs, Site Class D) 1.Q 1.464 (SM1, Site Class D) Conterminous 48 States 2006 Internatlona 1 Building Code Latitude = 34.1095 Longitude =- 117.7597 Design Spectral Response Accelerations SDs and SD1 SDs =2f3xSMs and SD1 =2 /SxSM1 Site Class 0 - Fa= 1.0,Fv =1.5 Period Sa (sec) (g). 0.2 1.716 (SDs, Site Class D) 1.0 0.976 (SD1, Site Class 0)• o 1/ C4/" 4')4'& .5 h, vetAC f li% / ... 3z.ii lacis 4111 --)r? 75 1? :tS7L( g'571 ' ate 116 . 0 sMS ~ 117 l� 5; 7 .W/ ` fm /' �0.Sf d C 1 Di" C rec.Lr CaAutCc Leti. GA-4 f er (l lr► „r /Car - 33($: •01 0 ' 0; !f I)V teceete pt 61 f fir i„,,6 js.-. t t pkY is^'i e ItLit ;v -S' 4', : 561"• Kit Yzol%ie --4,7 Iloty, 604 GcZ ,0:r E;(4 £c,r w % 60„ = 0, e)5111' • VA Ceps ~ /q Gok. - 0,04r 64C S;:. 51ifttcr5 € p /'eJti4 ctkit7,.4. ce.„, (A_3e 0) - 11 1- Eckcj, 1464- 1 <- AoLptei/ GAvl, Cznot, King County Always at your service KING COUNTY HOME I NEWS I SERVICES I DIRECTORY I CONTACT King County E- commerce Property Tax Web: Real Property Account Information Account/Parcel Summary Tax Account Number 197720013501 Parcel Number 1977200135 Account Status This account is active. Tax Payer Name PORT OF SEATTLE 072274 Mailing Address PO BOX 1209 PIER 66 SEATTLE WA 98111 Payment Status SECOND HALF AMOUNT IF PAID OR POSTMARKED BY OCTOBER 31, 2012. Annual Statement Requested By Statement Request Request Statement to be Mailed Penalty: $ 0.00 Select Payment Amount 2012 Balance: Current Year Tax Select Pay First Half 2012 • Pay Second Half 2012 $996.08 0 Actions 1 Add To Cart j View Cart Search Again TO PAY MULTIPLE ACCOUNTS WITH ONE PAYMENT: After clicking on the appropriate select box(es) and the "Add to Cart" button, click "Search Again" to continue locating and adding parcels /accounts. If you would like to pay by mail, make your check payable to King County Treasury. Write your tax account number on your check and send it to: King County Treasury 500 Fourth Avenue, Room 600 Seattle, WA 98104 Tax Year Details Receipts 2012 Tax/Fee Distribution 2012 Tax Information Tax: $ 0.00 Other Charges Surface Water $ 1,979.94 Noxious Weed $ 2.25 Conservation $ 9.98 Total billed: $ 1,992.17 Amount paid: $ 996.09 Interest: $ 0.00 Penalty: $ 0.00 2012 Balance: $ 996.08 Land value: $ 0 Improvement value: $ 0 Levy code:0010 Status: Exempt Omit year: 0000 2011 Tax Information Tax: $ 0.00 Other Charges Surface Water $ 1,778.20 Noxious Weed $ 2.25 Conservation $ 9.98 Land value: $ 0 Improvement value: $ 0 Levy code:0010 Status: Exempt Omit year: 0000 FELE COPY LENNOX).. p „. Product Submittal Project Information Project Name: TARGET # T0627 TUKWILA, WA Project Number: 3000240414 Project Location: TARGET # T0627 / REPLACEMENT 301 STRANDER BLVD TUKWILA, WA 98188, US Project Altitude: 1000 Customer Information Company Name: Target Company Address: 50 S 10th St TP3 -0760 Company Location: Minneapolis, MN 55403 -2054 Contact: Phone: 612-761-1257 En ' ineerin ' Information Company Name: Company Address: Company Location: Contact: Phone: REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 4 2012 City of Tukwila BUILDING DIVISION A We are pleased to provide the attached project submittal. If you have any questions or need additional information, please feel free to call our office. Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 1 of 52 R V CITY P 14 2012 PERMIT CENTER Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972-497-6869 m Li Lennox Industries Inc. - Product Submittal Table of Contents System ID Qty Model Description RTU1A / HOR 1 LGH036H4E PKGGE /3TON /CONFIGURABLE RTU 1 B / HOR 1 LGH072H4B PKGGE /6TON /CONFIGURABLE RTU2A / HOR 1 LGH072H4B PKGGE /6TON /CONFIGURABLE RTU2B / HOR 1 LGH072H4B PKGGE /6TON /CONFIGURABLE DHUO3 DHUO5 DHU11 3 LGH150S4B PKGGE /12.5TON /CONFIGURABLE RTU4 RTU6 RTU13 RTU 15 / GE 4 LGH150S4B PKGGE /12.5TON /CONFIGURABLE RTU7 RTU10 RTU12 RTU 14 / EE 4 LCH150S4B PKGEE /12.5TON /CONFIGURABLE RTUO8 RTUO9 / EE 2 LCH120H4B PKGEE /10TON /CONFIGURABLE RTU16 / EE 1 LCH150S4B PKGEE /12.5TON /CONFIGURABLE RTU 18 1 LGH 150S4B PKGGE /12.5TON /CONFIGURABLE Project: 3000240414 TARGET # T0627 TUKW ILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 2 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 ,Lennox Industries Inc. - Product Submittal System ID: RTUTA / HOR Package Model: LGH036H4E Description: PKGGE /3TON /CONFIGURABLE HEATING PERFORMANCE Heat Source H/E Highlnput H/E HighOutput System HeatOutput Natural Gas 65000 (Btuh) 52000 (Btuh) 52000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 36.5 ( °F) 80 1 11 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool AR1 NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R -410A 12.5 17.0 2800 (W) 35800 (Btuh) 35200 (Btuh) 36350 (Btuh) 35158 (Btuh) 29262 (Btuh) 28070 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 2 1.00 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 58.2 ( °F) 57.9 ( °F) 59.1 ( °F) 58.2 ( °F) 6.7 (lb /hr) 6.7 (lb /hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM Motor Torque Pct 1320 (cfm) 1320 (cfm) 0.70 (in.WC) 0.50 (hp) 0.50 (hp) MSAV Direct Drive 1065 (rpm) 77 TotalStaticPress Wet Coil Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.84 (in.WC) 0.06 (in.WC) 0.04 (in.WC) 0.04 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 10.0 (amp) 15 (amp) 4.5 (amp) 8.8 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA 2.2 (amp) 2.1 (amp) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight Horizontal Supply Height Horizontal Supply Width 47.0 (in.) 85.3 (in.) 38.9 (in.) 568 (lb) 20.0 (in.) 19.5 (in.) Horizontal Return Height Horizontal Return Width 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 75 (db) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 3 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTUTA / HOR Package Model: LGH036H4E Description: PKGGE /3TON /CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre - charged Refrigeration System Expansion Valves High Capacity Driers Low Pressure Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F ( -17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on aluminized heat exchanger of 10 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GFCI - FACTORY INSTALLED /FIELD WIRED BY ELECTRICIAN BAROMETRIC RELIEF DAMPERS PVC DRAIN TRAP 2 IN MERV8 FILTER CIRCUIT BREAKER GLOBAL ECONOMIZER TARGET ALC -READY STANDARD CAP INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 17W45 11408 1 1 T1HECKOOAN1 HORIZ. ECONO CONVERSION KT RTU LABELING Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKW ILA, WA Page 4 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU1A / HOR Package Model: LGH036H4E Description: PKGGE /3TON /CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF GG HH Ibs. kg lbs. kg Ibs. kg Ibs. kg in. mm in. mm in. mm in. mm LGH036 Std. Unit 98 45 119 54 192 87 158 72 38.5 978 18 457 29 737 46.75 1187 LGH036 Max. Unit 132 60 149 68 241 109 213 97 40 1016 18 457 29 737 45.25 1149 LGH048 Std. Unit 104 47 126 57 202 92 167 76 38.5 978 18 457 29 737 46.75 1187 LGH048 Max. Unit 140 64 158 72 255 116 225 102 40 1016 18 457 29 737 45.25 1149 LGH060 Std. Unit 118 54 144 65 232 105 191 87 38.5 978 18 457 29 737 46.75 1187 LGH060 Max. Unit 159 72 179 82 289 131 256 116 40 1016 18 457 29 737 45.25 1149 LGH072 Std. Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 29 737 46.75 1187 LGH072 Max. Unit 167 76 189 86 305 138 269 122 40 1016 18 457 29 737 45.25 1149 Std. Unit - fie unit with NO OPTIONS. Max. Unit - The unit with ALL OPTIONS Installed. (Economizer, etc.) I- (1143) 100 O —a I 1 (25) I I COl 8 AA 7( 78) 55/8 11 143 (279) 16-1/4 18 (413) (457) BOTTOM RETURN OPENING 5 (102) 29 (737) 47(1192) BASE S 2 m 3-1 L47 (1192) j� BASE �-l1 LIFTING HOLE END VIEW Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 5 of 52 (For rigging) 25-3/4 9-1 i2 (241) DD 26.1/2 (673) BOTTOM BOTTOM POWER ENTRY CONDENSATE OUTLET 3 X 8 (76 X 203) TOP VIEW (Base) SIDE VIEW 11 BB CC 1 (25) 19.1/2 163/8 (279)J 2(51) (495) (467) _ I- IIIi i 63.1/4 (2115) Jl • i 7 = j I CONDENSATE OUTLET (EITHER SIDE) FLUENENT OUTLET \ u ELECTRICAL INLET GAS INLET -�-� ___ T ^ ^^ 15(381) —...' 5-1/2 (140) /2(69) 0C I I f 1 > 00� 26-1/2 t 85-1/4 (2165) 27 (673) ._ ( ) SIDE VIEW 11 BB CC 1 (25) 19.1/2 163/8 (279)J 2(51) (495) (467) _ I- IIIi i II II' I II 1 11 111:11111 11111' l 2p (508) -�-� FORKLIFT SLOTS HORIZONTAL (Front, Back and SUPPLY AIR Bbwcr End) OPENING BACK VIEW 29 (77) J t I / 0L 7 5-1/2 5-1/2 S1i2 (140) RETUR NAIR (140) (Without Economizer) Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU1A / HOR Package Model: LGH036H4E Description: PKGGE /3TON /CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL WITH OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Horizontal Applications) SUPPLY AIR DUCT (Field Provided) SUPPLY Al R OUTLET TOP VIEW 19-1/2 (495) fll-1 ECONOMIZER DAMPERS RETURN AIR DUCT TRANSITION (Field fabricated and installed on unit) 29-1/4 (743) HORIZONTAL SUPPLY AIR OPENING BACK VIEW This opening 1 not used in Horizontal Applications with 20 Economizer (508) I L_J I I o ll RETURN AIR INLET RETURN AIR DUCT (Field Fabricated - Must be sized to accommodate Barometric Relief Hood and Return Air Requirements) BAROMETRIC RELIEF HOOD DIMENSIONS Width - 35 -1/2 in. (902 mm) Height -21 in. (533 mm) (036. 048) 25 in. (635 mm) (060. 072) See previous page for detais. OUTDOOR AIR HOOD (Furnished with Economizer) .7 5 (127) RETURN AIR DUCT TRANSITION (Field fabricated and installed on unit) BAROMETRIC RELIEF HOOD (Furnished with Economizer and Field Installed on Field fabricated Return Air Duct) OUTDOOR AIR HORIZONTAL RETURN AIR OPENING EXHAUST Al R RETURN AIR DUCT INLET (Field Fabricated - Must be sized to accommodate Barometric Relief Hood and Return Air Requirements) NOTE - Retum Air Duct and Transition must be supported. Model No. A in. mm B in. mm 036, 048 18 -3/4 476 060, 072 22 -1/2 572 11 -3/4 298 15-3/4 400 Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 6 of 52 1l 7/8 (22) 00 2 -1/4 (57) UNIT RETURN AIR DUCT OPENING WITH ECONOMIZER INSTALLED END VIEW Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 7/8 i (22) 2 -1/4 t (57) A 30 -7/16 a (n3; Model No. A in. mm B in. mm 036, 048 18 -3/4 476 060, 072 22 -1/2 572 11 -3/4 298 15-3/4 400 Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 6 of 52 1l 7/8 (22) 00 2 -1/4 (57) UNIT RETURN AIR DUCT OPENING WITH ECONOMIZER INSTALLED END VIEW Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU1A / HOR Package Model: LGH036H4E Description: PKGGE /3TON /CONFIGURABLE UNIT CLEARANCES - INCHES (MM) C OUTDOOR A B I'r D 1 AIR in. 1 , mm in. mm in. mm 1 Unit Clearance A B C D To Clearance in. mm in. mm in. mm in. mm Service Clearance 48 1219 36 914 36 934 36 914 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 7 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU1B / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE HEATING PERFORMANCE Heat Source HIE Highlnput H/E HighOutput System HeatOutput Natural Gas 65000 (Btuh) 52000 (Btuh) 52000 (Btuh) Gas Supply Connection HIE Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 20.7 ( °F) 80 1 11 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R -410A 12.0 12.5 6000 (W) 73500 (Btuh) 72000 (Btuh) 76622 (Btuh) 73289 (Btuh) 56868 (Btuh) 53535 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 1 1.00 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 55.9 ( °F) 55.9 ( °F) 57.3 ( °F) 56.5 ( °F) 18.6 (lb/hr) 18.6 (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 2325 (cfm) 2325 (cfm) 0.70 (in.WC) 1.04 (hp) 2.00 (hp) CAV Belt Drive 807 (rpm) 632 (rpm) 875 (rpm) TotalStaticPress Wet Coil Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.92 (in.WC) 0.12 (in.WC) 0.05 (in.WC) 0.05 (in.WC) 4 20.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 17.0 (amp) 25 (amp) 9.7 (amp) 14.5 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 3.4 (amp) 1.4 (amp) 410 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight Horizontal Supply Height Horizontal Supply Width 47.0 (in.) 85.3 (in.) 46.9 (in.) 762 (lb) 20.0 (in.) 19.5 (in.) Horizontal Return Height Horizontal Return Width 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 82 (db) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 8 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU1B / HOR Package Model: LGH072H4B Description: PKGGE /ETON /CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre - charged Refrigeration System Expansion Valves High Capacity Driers Low Pressure Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F ( -17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on aluminized heat exchanger of 10 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GFCI - FACTORY INSTALLED /FIELD WIRED BY ELECTRICIAN BAROMETRIC RELIEF DAMPERS PVC DRAIN TRAP 2 IN MERV8 FILTER CIRCUIT BREAKER GLOBAL ECONOMIZER TARGET ALC -READY STANDARD CAP INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 17W45 11408 1 T1HECKOOAN1 HORIZ. ECONO CONVERSION KT RTU LABELING Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 9 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 ,Lennox Industries Inc. - Product Submittal System ID: RTU1B / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF GG HH Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm in. mm in. mm LGH036 Std. Unit 98 45 119 54 192 87 158 72 38.5 978 18 457 29 737 46.75 1187 LGH036 Max. Unit 132 60 149 68 241 109 213 97 40 1016 18 457 29 737 45.25 1149 LGH048 Std. Unit 104 47 126 57 202 92 167 76 38.5 978 18 457 29 737 46.75 1187 LGH048 Max. Unit 140 64 158 72 255 116 225 102 40 1016 18 457 29 737 45.25 1149 LGH060 Std. Unit 118 54 144 65 232 105 191 87 38.5 978 18 457 29 737 46.75 1187 LGH060 Max. Unit 159 72 179 82 289 131 256 116 40 1016 18 457 29 737 45.25 1149 LGH072 Std. Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 29 737 46.75 1187 LGH072 Max. Unit 167 76 189 86 305 138 269 122 40 1016 18 457 29 737 45.25 1149 Std. Unit - The unit with NO OPTIONS. Max. Unit -The unit with ALL OPTIONS Installed. (Economizer, etc.) 45 (1143) I 1 (2s) loo I 1 I I col (1192)_.1 BASE END VIEW Project: 3000240414 TARGET # T0627 TUKW ILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 10 of 52 AA 7( 78) 5.5/8 11 16.1/4 143 (279) (413/) (457) 18 BOTTOM RETURN AIR OPENING 47(1192) BASE 29 (737) 25-3/4 3-1 LIFTING HOLE (For rigging) DD 26-1/2 (673) BOTTOM CONDENSATE OUTLET • 9.1 C EE C (241) BB BOTTOM POWER ENTRY 3 X8(76 X203) TOP VIEW (Base) 85-1/4 (2165) BASE SIDE VIEW 19-1;2 18-316 (495) (467) 5) 11 (279) (51) 1111 1 1 11 '11111 111111 11,1 III 1:11 111: IlIi1 53-114 (2115) i ?_ = r CO OUTLET OUTLET (EITFER SIDE, FLUENENT OUTLET \ — -_ - ELECTRICAL INLET GAS INLET j T 15 (381) —► 5-1/2 (140) /2(89) roc I I 1 1 OO)I /I 26-112 t 27 11 _ Ilrr"' !6711 —�' _ (6861 I 85-1/4 (2165) BASE SIDE VIEW 19-1;2 18-316 (495) (467) 5) 11 (279) (51) 1111 1 1 11 '11111 111111 11,1 III 1:11 111: IlIi1 20 - 29 (737) CO - / I t /UL HORIZONTAL 5-1/2 ROPENINGR (5140 (Without Economizer) FORKLIFT SLOTS HORIZONTAL (Front, Back and SUPPLY AIR Bower End) OPENING BACK VIEW Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 ,Lennox Industries Inc. - Product Submittal System ID: RTU1B / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL WITH OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Horizontal Applications) u a L0_ ECONOMIZER DAMPERS SUPPLY AIR DUCT (Field Provided) SUPPLY AIR OUTLET TOP VIEW RETURN AIR DUCT TRANSITION (Field fabricated and installed on unit) X19 -1/2 _ _ 29-1/4 (495) (743) C HORIZONTAL SUPPLY AIR OPENING I- --1 This opening 1 not used in Horizontal Applications 1 with 20 Economizer (508) I L_J RETURN AIR INLET RETURN AIR DUCT (Field Fabricated - Must be sized to accommodate Barometric Relief Hood and Return Air Requirements) BAROMETRIC RELIEF HOOD DIMENSIONS Width - 35-1/2 in. (902 mm) Height -21 in. (533 mm) (036. 048) 25 in. (635 mm) (060.072) See previous page for detais. OUTDOOR AIR HOOD (Furnished with Economizer) BAROMETRIC RELIEF HOOD (Furnished with Economizer and Field Instated on Field fabricated Return Air Duct) OUTDOOR AIR I 1 00 BACK VIEW 5(127) RETURN AIR DUCT TRANSITION (Field fabricated and installed on unit) HORIZONTAL RETURN AIR OPENING EXHAUST AIR RETURN AIR DUCT INLET (Field Fabricated - Must be sized to accommodate Barometric Relief Hood and Return Air Requirements) NOTE - Retum Air Duct and Transition must be supported. 2 -1/4 (�__ 7/8 (22) 4 r A 30 -7/16 (773) \- 0 L_.J 7/8 (22) Model No. A in. mm B in. mm 036.048 18 -3/4 476 060, 072 22 -1/2 572 11 -3/4 298 15-3/4 400 Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKW ILA, WA Page 11 of 52 O: 2-1/4 (57) UNIT RETURN AIR DUCT OPENING WITH ECONOMIZER INSTALLED END VIEW Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 ,Lennox Industries Inc. - Product Submittal System ID: RTU1B / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE UNIT CLEARANCES - INCHES (MM) OUTDOOR HOOD A i i C Top Clearance AIR mm in. if '/ +: mm in. Unit Clearance A B C D Top Clearance in. mm in. mm in. mm in. mm Service Clearance 48 1219 36 914 36 934 36 914 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. ' Service Clearance - Required for removal of serviceable pans. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000240414 TARGET # T0627 TUKW ILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 12 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 . Lennox Industries Inc. - Product Submittal System ID: RTU2A / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE HEATING PERFORMANCE Heat Source H/E Highlnput H/E HighOutput System HeatOutput Natural Gas 65000 (Btuh) 52000 (Btuh) 52000 (Btuh) Gas Supply Connection HIE Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 21.4 ( °F) 80 1 11 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R -410A 12.0 12.5 6000 (W) 73500 (Btuh) 72000 (Btuh) 76044 (Btuh) 73111 (Btuh) 55845 (Btuh) 52912 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 1 1.00 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 55.6 ( °F) 55.6 ( °F) 56.9 ( °F) 56.1 ( °F) 19.0 (lb/hr) 19.0 (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 2250 (cfm) 2250 (cfm) 0.60 (in.WC) 0.95 (hp) 1.00 (hp) CAV Belt Drive 767 (rpm) 522 (rpm) 784 (rpm) TotalStaticPress Wet Coil Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.82 (in.WC) 0.12 (in.WC) 0.05 (in.WC) 0.05 (in.WC) 4 20.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 16.0 (amp) 25 (amp) 9.7 (amp) 13.2 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 2.1 (amp) 1.4 (amp) 410 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight Horizontal Supply Height Horizontal Supply Width 47.0 (in.) 85.3 (in.) 46.9 (in.) 762 (lb) 20.0 (in.) 19.5 (in.) Horizontal Return Height Horizontal Return Width 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 82 (db) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKW ILA, WA Page 13 of 52 Last Changed: JANE'GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU2A / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre - charged Refrigeration System Expansion Valves High Capacity Driers Low Pressure Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F ( -17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on aluminized heat exchanger of 10 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GFCI - FACTORY INSTALLED /FIELD WIRED BY ELECTRICIAN BAROMETRIC RELIEF DAMPERS PVC DRAIN TRAP 2 IN MERV8 FILTER CIRCUIT BREAKER GLOBAL ECONOMIZER TARGET ALC -READY STANDARD CAP INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 17W45 11408 1 1 T 1 HECKOOAN 1 HORIZ. ECONO CONVERSION KT RTU LABELING Project: 3000240414 TARGET # T0627 TUKW ILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 14 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU2A / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF GG HH Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm in. mm in. mm LGH036 Std. Unit 98 45 119 54 192 87 158 72 38.5 978 18 457 29 737 46.75 1187 LGH036 Max. Unit 132 60 149 68 241 109 213 97 40 1016 18 457 29 737 45.25 1149 LGH048 Std. Unit 104 47 126 57 202 92 167 76 38.5 978 18 457 29 737 46.75 1187 LGH048 Max. Unit 140 64 158 72 255 116 225 102 40 1016 18 457 29 737 45.25 1149 LGH060 Std. Unit 118 54 144 65 232 105 191 87 38.5 978 18 457 29 737 46.75 1187 LGH060 Max. Unit 159 72 179 82 289 131 256 116 40 1016 18 457 29 737 45.25 1149 LGH072 Std. Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 29 737 46.75 1187 LGH072 Max. Unit 167 76 189 86 305 138 269 122 40 1016 18 457 29 737 45.25 1149 Std. Unit - The unit with NO OPTIONS. Max. Unit - The unit with ALL OPTIONS Installed. (Economizer, etc.) 1 1 (25) loo I 1 O Co) 47ASE2j� BASE END VIEW Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKW ILA, WA Page 15 of 52 5-5/8 11 (143 16-1/4 18 (279) (413) (457) 7( 78) BOTTOM RETURN AIR OPENING 5 (102) 47 (1192) BASE 29 (737) S 2 3-1 LIFTING HOLE (For rigging) 25-3/4 (654) 9.1/2 (241) BB DD I \ \ I CC 26.1/2 (673) BOTTOM CONDENSATE OUTLET TOP VIEW (Base) BOTTOM POWER ENTRY 3 X8(76 X203) 85-1/4 (2165) BASE SIDE VIEW 19-1/2 (495) 11 (279) 18 -3/8. (467) Iii III i 1111 I' I11 : Ills) i II. I� I o o A.= FORKLIFT SLOTS HORIZONTAL HORIZONTAL (Front. Back and SUPPLY AIR (10) RETURN AIR ((14o Blower End) OPENING OPENING ) (Without Economizer) 5) BACK VIEW Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 83.1f4 (2115) CONDENSATE CONDENSATE OUTLET (EITFER SIDE) FLUENENT OUTLET \ ELECTRICAL / INLET GAS INLET - ----- __ ® c— 15(381) —`I 5-1/2 (140) /2(89) I /IIIOC I I 26-1/2 I f I ool t 27 _ - -- (A731 _ (6861 85-1/4 (2165) BASE SIDE VIEW 19-1/2 (495) 11 (279) 18 -3/8. (467) Iii III i 1111 I' I11 : Ills) i II. I� I o o A.= FORKLIFT SLOTS HORIZONTAL HORIZONTAL (Front. Back and SUPPLY AIR (10) RETURN AIR ((14o Blower End) OPENING OPENING ) (Without Economizer) 5) BACK VIEW Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 .Lennox Industries Inc. - Product Submittal System ID: RTU2A / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL WITH OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Horizontal Applications) SUPPLY AIR DUCT (Field Provided) SUPPLY AIR OUTLET TOP VIEW 19 -12 (495) 9711 u u 0 LII_ ECONOMIZER DAMPERS RETURN AIR DUCT TRANSITION (Field fabricated and installed on unit) 29-1/4 (743) B RETURN AIR INLET s .t2 0 g RETURN AIR DUCT (Field Fabricated - Must be sized to accommodate Barometric Relief Hood and Return Air Requirements) BAROMETRIC RELIEF HOOD DIMENSIONS Width • 35-1/2 in. (902 mm) Height -21 in. (533 mm) (036. 048) 25 in. (635 mm) (060. 072) See previous page for deta)s. OUTDOOR AIR HOOD (Furnished with Economizer) HORIZONTAL SUPPLY AIR OPENING This opening 1 not used in Horizontal Applications 1 with 20 Economizer (508) 1 - L_1 BACK VIEW I I 5 (127) BAROMETRIC RELIEF HOOD (Furnished with Economizer and Field Installed on Field fabricated Return Air Duct) OUTDOOR AIR C) C.71 RETURN AIR DUCT TRANSITION (Field fabricated and installed on unit) HORIZONTAL RETURN AIR OPENING RETURN AIR DUCT INLET (Field Fabricated - Must be sized to accommodate Barometric Relief Hood and Return Air Requirements) NOTE - Retum Air Duct and Transition must be supported. 100 I t1 C� 7/8 Model No. A in. mm B in. mm 036, 048 18 -3/4 476 060, 072 22 -1/2 572 11 -3/4 298 15-3/4 400 Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 16 of 52 (22) 2 -1/4 (57) UNIT RETURN AIR DUCT OPENING WITH ECONOMIZER INSTALLED END VIEW Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 7/8 11l(22) 2 -1/4 I (5—D. „r 30 -7/16 .... — (773) 100 I t1 C� 7/8 Model No. A in. mm B in. mm 036, 048 18 -3/4 476 060, 072 22 -1/2 572 11 -3/4 298 15-3/4 400 Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 16 of 52 (22) 2 -1/4 (57) UNIT RETURN AIR DUCT OPENING WITH ECONOMIZER INSTALLED END VIEW Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU2A / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE UNIT CLEARANCES - INCHES (MM) P Unit Clearance A - C D - B OUTDOOR AIR mm HOOD mm i, . v mm in. mm P Unit Clearance A B C D To Clearance in. mm in. mm in. mm in. mm Service Clearance 48 1219 36 914 36 934 36 914 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000240414 TARGET # T0627 TUKW ILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 17 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU2B / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE HEATING PERFORMANCE Heat Source WE HighInput WE HighOutput System HeatOutput Natural Gas 65000 (Btuh) 52000 (Btuh) 52000 (Btuh) Gas Supply Connection WE Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 22.3 ( °F) 80 1 11 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R -410A 12.0 12.5 6000 (W) 73500 (Btuh) 72000 (Btuh) 75350 (Btuh) 72335 (Btuh) 54629 (Btuh) 51614 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 1 1.00 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 55.1 ( °F) 55.1 ( °F) 56.5 ( °F) 55.7 ( °F) 19.5 (lb/hr) 19.5 (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM Field Drive Required 2160 (cfm) 2160 (cfm) 0.70 (in.WC) 0.94 (hp) 1.00 (hp) CAV Belt Drive 785 (rpm) 522 (rpm) 784 (rpm) Req RPM above drive range TotalStaticPress Wet Coil Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.91 (in.WC) 0.11 (in.WC) 0.05 (in.WC) 0.05 (in.WC) 4 20.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 16.0 (amp) 25 (amp) 9.7 (amp) 13.2 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 2.1 (amp) 1.4 (amp) 410 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight Horizontal Supply Height Horizontal Supply Width 47.0 (in.) 85.3 (in.) 46.9 (in.) 762 (lb) 20.0 (in.) 19.5 (in.) Horizontal Return Height Horizontal Return Width 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 82 (db) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 18 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 -Lennox Industries Inc. - Product Submittal System ID: RTU2B / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre - charged Refrigeration System Expansion Valves High Capacity Driers Low Pressure Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F ( -17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on aluminized heat exchanger of 10 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GFCI - FACTORY INSTALLED /FIELD WIRED BY ELECTRICIAN BAROMETRIC RELIEF DAMPERS PVC DRAIN TRAP 2 IN MERV8 FILTER CIRCUIT BREAKER GLOBAL ECONOMIZER TARGET ALC -READY STANDARD CAP INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 17W45 11408 1 1 T1HECKOOANI HORIZ. ECONO CONVERSION KT RTU LABELING Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 19 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 - 497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU2B / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF GG HH Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm in. mm in. mm LGH036 Std. Unit 98 45 119 54 192 87 158 72 38.5 978 18 457 29 737 46.75 1187 LGH036 Max. Unit 132 60 149 68 241 109 213 97 40 1016 18 457 29 737 45.25 1149 LGH048 Std. Unit 104 47 126 57 202 92 167 76 38.5 978 18 457 29 737 46.75 1187 LGH048 Max. Unit 140 64 158 72 255 116 225 102 40 1016 18 457 29 737 45.25 1149 LGH060 Std. Unit 118 54 144 65 232 105 191 87 38.5 978 18 457 29 737 46.75 1187 LGH060 Max. Unit 159 72 179 82 289 131 256 116 40 1016 18 457 29 737 45.25 1149 LGH072 Std. Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 29 737 46.75 1187 LGH072 Max. Unit 167 76 189 86 305 138 269 122 40 1016 18 457 29 737 45.25 1149 Std. Unit - The unit with NO OPTIONS. Max. Unit - The unit with ALL OPTIONS Installed. (Economizer, etc.) 45 (1143) loop t5) (25) 1 5-5/8 11 16-1/4 (143) (279) (413) (457) 18 AA 7 ( 78) 47 (1192) BASE 29 (737) 3-1 47(1192) I BASE LIFTING HOLE (For rigging) END VIEW Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 20 of 52 BOTTOM 5(102) RETURN AIR OPENING 20 iiru BOTTOM," (508) l' OPENING CENTER T7 X GRANVITY I _ FIF \ ,\ 1 DD 26-1/2 (673) 25-3/4 9.1 ;2 (241) BB I EE .1 CC BOTTOM BOTTOM POWER ENTRY CONDENSATE OUTLET 3 X 8 (76 X 203) TOP VIEW (Base) 85-1/4 (2165) BASE SIDE VIEW ,,19.1 ;2 (495) 11 18-318 (279) (467) III I 1 !III d[li (3 ) 29 O ►III: ►I 1 / / LLD I I /,(.= L FORKLIFT SLOTS HORIZONTAL t HORIZONTAL 7 (Front. Back and SUPPLY AIR 5-112 RETURN AIR 5-V2 Blower End) OPENING (140) OPENING (140) Qthout Economizer) 5) _2'51) BACK VIEW Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 83.114 (2115) _? i i .7,* I CONDENSATE OUTLET (EITlER SIDE) \ FLUENENT OUTLET ® ELECTRICAL INLET GAS INLET _ _ - ^^ 15 (381) .y I + 5-1/2 (140) /2 (891 IOC I 1 t 0 0 /i_ 26-1/2 t 27 I— fR711 WE 85-1/4 (2165) BASE SIDE VIEW ,,19.1 ;2 (495) 11 18-318 (279) (467) III I 1 !III d[li (3 ) 29 O ►III: ►I 1 / / LLD I I /,(.= L FORKLIFT SLOTS HORIZONTAL t HORIZONTAL 7 (Front. Back and SUPPLY AIR 5-112 RETURN AIR 5-V2 Blower End) OPENING (140) OPENING (140) Qthout Economizer) 5) _2'51) BACK VIEW Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU2B / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL WITH OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Horizontal Applications) LI ECONOMIZER DAMPERS SUPPLY AIR DUCT (Field Provided) SUPPLY AIR OUTLET TOP VIEW 19 -12 (495) RETURN AIR DUCT TRANSITION (Field fabricated and installed on unit) 29-1/4 (743) HORIZONTAL SUPPLY AIR OPENING BACK VIEW r -� This opening 1 not used in Horizontal Applications 1 with 20 Economizer RETURN AIR INLET RETURN AIR DUCT (Field Fabricated - Must be sized to accommodate Barometric Relief Hood and Return Air Requirements) BAROMETRIC RELIEF HOOD DIMENSIONS Width - 35 -1/2 in. (902 mm) Height -21 in. (533 mm) (036. 048) 25 in. (635 mm) (060.072) See previous page for details. OUTDOOR AIR HOOD (Furnished with Economizer) B1 BAROMETRIC RELIEF HOOD (Fumished with Economizer and Field Installed on Field fabricated Return Air Duct) OUTDOOR AR (508) 1 O� L -J I 1 0 01/ 5 (127) RETURN AIR DUCT TRANSITION (Field fabricated and installed on unit) HORIZONTAL RETURN AIR OPENING 7/8 RETURN AIR DUCT INLET (22) (Field Fabricated - Must be sized to accommodate Barometric Relief \ 00 2 -1/4 (57) UNIT RETURN AIR DUCT OPENING IMTH ECONOMIZER INSTALLED Hood and Return Air Requirements) END VIEW NOTE - Return Air Duct and Transi8on must be supported. Model No. A in. mm B in. mm 036, 048 18 -3/4 476 060, 072 22 -1/2 572 11 -3/4 298 15-3/4 400 Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 21 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 7/8 i (22) 2 -1/4 1 (57) y A t (773) [ll 7/8 RETURN AIR DUCT INLET (22) (Field Fabricated - Must be sized to accommodate Barometric Relief \ 00 2 -1/4 (57) UNIT RETURN AIR DUCT OPENING IMTH ECONOMIZER INSTALLED Hood and Return Air Requirements) END VIEW NOTE - Return Air Duct and Transi8on must be supported. Model No. A in. mm B in. mm 036, 048 18 -3/4 476 060, 072 22 -1/2 572 11 -3/4 298 15-3/4 400 Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 21 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 . Lennox Industries Inc. - Product Submittal System ID: RTU2B / HOR Package Model: LGH072H4B Description: PKGGE /6TON /CONFIGURABLE UNIT CLEARANCES - INCHES (MM) OUTDOOR WOOD A ; ; ,. l S, D AIR in. t .I �J 'J mm in. i Unit Clearance A B C D To Clearance in. mm in. mm in. mm in. mm Service Clearance 48 1219 36 914 36 934 36 914 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 22 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 •Lennox Industries Inc. - Product Submittal System ID: DHUO3 DHU05 DHU1 1 Package Model: LGH150S4B Description: PKGGE /12.5TON /CONFIGURABLE HEATING PERFORMANCE Heat Source H/E Lowlnput H/E LowOutput H/E HighInput 1-I/E HighOutput System HeatOutput Natural Gas 117000 (Btuh) 93500 (Btuh) 180000 (Btuh) 144000 (Btuh) 144000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.75 (in.) 35.6 ( °F) 80 2 11 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R -410A 10.8 11.0 12600 (W) 144000 (Btuh) 138000 (Btuh) 138942 (Btuh) 132176 (Btuh) 96796 (Btuh) 90030 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 2 2 1.00 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 54.6 ( °F) 54.4 ( °F) 56.4 ( °F) 55.1 ( °F) 39.7 ( lb/hr) 39.7 (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 3750 (cfm) 3750 (cfm) 0.70 (in.WC) 2.26 (hp) 3.00 (hp) CAV Belt Drive 980 (rpm) 940 (rpm) 1200 (rpm) TotalStaticPress Wet Coil Static Press Gas H/E Static Press Added Filter Static Press Humiditrol Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 1.39 (in.WC) 0.42 (in.WC) 0.19 (in.WC) 0.03 (in.WC) 0.05 (in.WC) 4 20.0 (in.) 25.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 27.0 (amp) 30 (amp) 19.4 (amp) 26.8 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 4.8 (amp) 2.6 (amp) 820 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 60.1 (in.) 101.3 (in.) 46.9 (in.) 1327 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 24.0 (in.) 27.0 (in.) SOUND Outdoor Sound Rating 88 (db) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKW ILA, WA Page 23 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: DHUO3 DHUO5 DHU11 Package Model: LGH150S4B Description: PKGGE /12.5TON /CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre - charged Refrigeration System Expansion Valves High Capacity Driers Low Pressure Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F ( -17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel lnshot Burners Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on aluminized heat exchanger of 10 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GFCI - FACTORY INSTALLED /FIELD WIRED BY ELECTRICIAN HUMIDITROL PVC DRAIN TRAP 2 IN MERV8 FILTER TARGET ALC -READY STANDARD CAP INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 11408 RTU LABELING Project: 3000240414 TARGET # T0627 TUKW ILA, WA Quote: 4000323816 TARGET # T0627 TUKW ILA, WA Page 24 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: DI-11.103 DHUO5 DHU11 Package Model: LGH150S4B Description: PKGGE /12.5TON /CONFIGURABLE DIMENSIONS - INCHES (MM) Model No. CORNER WEIGHTS CENTER OF GRAVITY AA BB CC DD EE FF Base Max. Base Max. Base Max. Base Max. Base Max. Base Max. lbs. kg Ibs. kg lbs. kg Ibs. kg lbs. kg lbs. kg lbs. kg lbs. kg In. mm In. mm in. mm in. mm 092 293 133 338 153 263 119 295 134 286 130 316 143 326 148 370 168 46.5 1181 45.5 1156 24.5 822 25.5 648 102 294 134 340 154 265 120 297 135 288 131 318 144 328 149 372 169 46.5 1181 45.5 1156 24.5 622 25.5 648 120 306 139 349 158 275 125 305 138 295 134 326 148 334 152 382 173 46.5 1181 45.5 1156 24.5 622 25.5 648 150 316 143 359 163 284 129 314 142 304 138 393 178 345 157 393 178 46.5 1181 45.5 1156 24.5 622 25.5 648 Base Lind - The unit with NO INTERNAL OPTIONS. Max. Lind - The unit with AU. INTERNAL OPTIONS Installed . (Economizer, Standard Static Power Exhaust Fans, Cordrds, e c.). Does not include accessories extemal b uric Or high static power exhaust. AA 6.118 (156)— 60 -18 (1527) BASE BOTTOM POWER ENTRY 5.12 (140) Oa. 58-1/8 (1476) 7 100 t= = • 0) ,x_60 -118 (1527) END VIEW 46-78 (1191) 43-3/8 3-1/2 (89) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 25 of 52 6-1/8 (156) 24 (610) 27 (686) 10-314 (273) 546 BOTTOM SUPPLY 043) BOTTOM OPENING t % —/ 28 20 (711) (58) CENTER OF 1 • `�'�GRAVITY BOTTOM RETURN :::j( AIR OPENING EE \. +.I tl (168 \ FF 7 (178) �t (168) r IjlF 4 4 DD 7 (178) CONDENSATE 34 -78 (886) (25) ELECTRIC )4LETS 15-1/2 (394) 101.1/4 BASE (2572) TOP VIEW OPTIONAL DISCONNECT (FACTORY WSTALIE0) 99-1/4 (2521) BB CC • CONDENSATE DRAIN (FRONT) GAS SUPPLY INLET / FLUE OUTLET 5-318\ 1137) " Mil 18 -112. (470) 34 -78 (886) • • 39.7/8 (1013) 7 FORKLIFT SLOTS (BOTH SIDES) LIFTING HOLES (FOR RIGGING) 46718 (1191) 101 -114 (2572) SIDE VIEW 15.12 (394) HORIZONTAL SUPPLY AIR OPENING II 1 HORIZONTAL RETURN AIR OPENING LO o T CONDENSATE 6-1/8 GRAIN (BACK) (156) 31.12 30 () �— (762) —► 66.38 r (1686 } 5-3/8 (137) SIDE VIEW (Horizontal Openings) rt� 1618 - I (41) 1 30 (762) 12-1/8 001 (308) Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972-497-6869 1 Lennox Industries Inc. - Product Submittal System ID: DHUO3 DHUO5 DHU11 Package Model: LGH150S4B Description: PKGGE /12.5TON /CONFIGURABLE UNIT CLEARANCES - INCHES (MM) OPrIONAL OUTDOOR AIR MOOD A 64//// C ��rirr_iiiii�"�/ %- -���///� - - 94 A/ / in. t Unit Clearance A B C D To Clearance in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 60 1524 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 26 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU4 RTU6 RTU13 RTU15 / GE Package Model: LGH150S4B Description: PKGGE /12.5TON /CONFIGURABLE HEATING PERFORMANCE Heat Source 1-1/E Lowlnput H/E LowOutput H/E HighInput H/E HighOutput System HeatOutput Natural Gas 117000 (Btuh) 93500 (Btuh) 180000 (Btuh) 144000 (Btuh) 144000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.75 (in.) 28.4 ( °F) 80 2 11 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R -410A 10.8 11.0 12600 (W) 144000 (Btuh) 138000 (Btuh) 145250 (Btuh) 134390 (Btuh) 111116 (Btuh) 100256 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 2 2 1.00 95.0 80.0 67.0 56.7 56.7 59.0 57.5 32.2 32.2 (in.) ( °F) ( °F) ( °F) ( °F) ( °F) ( °F) ( °F) (lb/hr) ( lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 4700 (cfm) 4700 (cfm) 0.70 (in.WC) 3.76 (hp) 5.00 (hp) CAV Belt Drive 1135 (rpm) 1040 (rpm) 1315 (rpm) TotalStaticPress Wet Coil Static Press Gas H/E Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness Number Exhaust Fans ExhaustFan NomPower 1.85 (in.WC) 0.58 (in.WC) 0.28 (in.WC) 0.05 ( in.WC) 0.24 (in.WC) 4 20.0 (in.) 25.0 (in.) 2.0 (in.) 1 0.3 (hp) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 31.0 (amp) 35 (amp) 19.4 (amp) 30.9 (amp) +/- 10% SupplyFan FLA Con densingUnit FLA CondenserFan Power 7.6 (amp) 2.6 (amp) 820 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 60.1 (in.) 101.3 (in.) 46.9 (in.) 1338 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 24.0 (in.) 27.0 (in.) SOUND Outdoor Sound Rating 88 (db) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 27 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU4 RTU6 RTU13 RTU15 / GE Package Model: LGH150S4B Description: PKGGE /12.5TON /CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre - charged Refrigeration System Expansion Valves High Capacity Driers Low Pressure Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F ( -17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on aluminized heat exchanger of 10 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GFCI - FACTORY INSTALLED /FIELD WIRED BY ELECTRICIAN STD STATIC PEF PVC DRAIN TRAP 2 IN MERV8 FILTER CIRCUIT BREAKER GLOBAL ECONOMIZER TARGET ALC -READY STANDARD CAP INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 11408 4 RTU LABELING Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 28 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 - 497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU4 RTU6 RTU13 RTU15 / GE Package Model: LGH150S4B Description: PKGGE /12.5TON /CONFIGURABLE DIMENSIONS - INCHES (MM) Model No. CORNER WEIGHTS CENTER OF GRAVITY AA BB CC DD EE FF Base Max. Base Max. Base Max. Base Max. Base Max. Base Max. Ibs. kg Ibs. kg Ibs. kg lbs. kg Ibs. kg lbs. kg Ibs. kg Ibs. kg in. mm In. mm In. mm in. mm 092 293 133 338 153 263 119 295 134 286 130 316 143 326 148 370 168 46.5 1181 45.5 1156 24.5 622 25.5 648 102 294 134 340 154 265 120 297 135 288 131 318 144 328 149 372 169 46.5 1181 45.5 1156 24.5 622 25.5 648 120 306 139 349 158 275 125 305 138 295 134 326 148 334 152 382 173 46.5 1181 45.5 1156 24.5 622 25.5 648 150 316 143 359 163 284 129 314 142 304 138 393 178 345 157 393 178 46.5 1181 45.5 1156 24.5 622 25.5 648 Base Unit - The unit with NO INTERNAL OPTIONS. Max. Unit - The unit with AU. INTERNAL OPTIONS Instaled. (Econom¢er, Standard Static Power Exhaust Fans, Cordrds, etc.), Doe; not include accessaies extemal b unit or high static power exhaust. 58-1/8 (14 (14766) Ion o C1 601 43.30 END VIEW 3-1/2 (89) 6-1/8 550 BOTTOM SUPPLY (156) (143) AIR OPENING AA � if / 6 (6-1561/8)_.. 1/fl )f 60 -1/8 (1527) BASE BOTTOM POWER ENTRY 5- 112(140) Da. Project: 3000240414 TARGET # T0627 TUKW ILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 29 of 52 24 (610) 2 (686) 10314 (273) 2a 20 (711) (508) l T \/ GRf BOTTOM RETURN OPENING AIROPENING EE I \ t 7(78) 6 F$ F f DD +.I se 4 BOTTOM 7 (178) CONDENSATE 34 -7$ () 101 -1/4 BASE (2572) TOP VIEW (25) OPT ONAL DISCONNECT (FACTORY INSTALLED) 99-1/4 (2521) 7 ea cc 004 CONDENSATE DRAIN (FRONT) 53/8 1137) I GAS SUPPLY INLET 0 FLUE OUTLET / ENE +61/24 (470) /o ELECTRIC INLETS 15-1/2 (394) 34-718 .0-- (886) • _ 39-7/8 (+013) • FORKLIFT SLOTS (BOTH SIDES) LIFTING HOLES (FOR RIGGING) 101-1/4 (2572) SIDE VIEW 15-112 (394) HORIZONTAL SUPPLY AIR OPENING HORIZONTAL RETURN AIR OPENNG C00 CONDENSATE CRAIN (RAMC) 5-3/8 (137) 3l -1_ 30 (800) 12 (762) 66.3!8 (1686 SIDE VIEW (Horizontal Openings) 46-7/8 (1191) 1 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 • Lennox Industries Inc. - Product Submittal System ID: RTU4 RTU6 RTU13 RTU15 / GE Package Model: LGH150S4B Description: PKGGE /12.5TON /CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL 21 -3/8 (543) OUTDOOR AIR HOOD (Fumished with Economizer or Outdoor Air Damper) EXHAUST AIR HOOD (Furnished, Field Installed) Project: 3000240414 TARGET # T0627 TUKW ILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 30 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 11 11. y 0 11 0 0 a 'IlIII 100 O I I 001 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU4 RTU6 RTU13 RTU l 5 / GE Package Model: LGH150S4B Description: PKGGE /12.5TON /CONFIGURABLE UNIT CLEARANCES - INCHES (MM) //, orr10HAL OUTD OOR AIR HOOD B ie 4 % % - - (w, gal, � � „ z mm ' Unit Clearance A B C D Top Clearance in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 60 1524 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. ' Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 31 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 - 497 -6869 • Lennox Industries Inc. - Product Submittal System ID: RTU7 RTU10 RTU12 RTU14 / EE Package Model: LCH150S4B Description: PKGEE /12.5TON /CONFIGURABLE HEATING PERFORMANCE Heat Source None COOLING PERFORMANCE Refrigerant ARI EER ARI LEER ARI Total Power ARI GrossTotalCool AR1 NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R -410A 11.0 11.2 12400 (W) 144000 (Btuh) 138000 (Btuh) 145250 (Btuh) 135448 (Btuh) 111116 (Btuh) 101314 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 2 2 1.00 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 56.7 ( °F) 56.7 ( °F) 58.8 ( °F) 57.5 ( °F) 32.2 (lb/hr) 32.2 (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 4700 (cfm) 4700 (cfm) 0.70 (in.WC) 3.39 (hp) 5.00 (hp) CAV Belt Drive 1074 (rpm) 900 (rpm) 1135 (rpm) TotalStaticPress Wet Coil Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness Number Exhaust Fans ExhaustFan NomPower 1.57 (in.WC) 0.58 (in.WC) 0.05 (in.WC) 0.24 (in.WC) 4 20.0 (in.) 25.0 (in.) 2.0 (in.) 1 0.3 (hp) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 31.0 (amp) 35 (amp) 19.4 (amp) 31.3 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 7.6 (amp) 3.0 (amp) 820 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 60.1 (in.) 101.3 (in.) 46.9 (in.) 1233 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 24.0 (in.) 27.0 (in.) SOUND Outdoor Sound Rating 88 (db) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 32 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU7 RTU10 RTU12 RTU14 / EE Package Model: LCH150S4B Description: PKGEE /12.5TON /CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre - charged Refrigeration System Expansion Valves High Capacity Driers Low Pressure Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control Units will operate cooling down to 0 degrees F ( -17.7 degrees C) without additional controls. Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GFCI - FACTORY INSTALLED /FIELD WIRED BY ELECTRICIAN STD STATIC PEF PVC DRAIN TRAP 2 IN MERV8 FILTER CIRCUIT BREAKER GLOBAL ECONOMIZER TARGET ALC -READY STANDARD CAP INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 11408 4 RTU LABELING Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 33 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU7 RTU10 RTU12 RTU14 / EE Package Model: LCH150S4B Description: PKGEE/ 12.5TON /CONFIGURABLE DIMENSIONS - INCHES (MM) Model No. CORNER WEIGHTS CENTER OF GRAVITY AA BB CC DD EE FF Base Max. Base Max. Base Max. Base Max. Base Max. Base Max. lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg In. mm in. mm in. mm in. mm 092 281 127 327 148 252 114 286 130 275 125 306 139 312 142358 162 46.5 1181 455 1156 24.5 622 25.5 648 102 282 128 329 149 254 115 287 130 276 125 308 139 314 143 360 163 46.5 1181 45.5 1156 24.5 622 25.5 648 120 294'133 340 154 264 120 297 135 283 128 318 144 321 146 372 169 46.5 1181 45.5 1156 24.5 622 25.5 648 150 304 138 350 159 273 124 306 139 293 133 327 148 332 151 383 174 46.5 1181 45.5 1156 24.5 622 25.5 648 ease Unit- The unit with NO INTERNAL OPTIONS, Max. Urit - The unit with AU. INTERNAL OPTIONS Instated. (Ecalanuer, Standard Static Power Exhaust Fans, Controls, etc.). Does not include accessories external to unit or high static power exhaust. 58-1,0 (1476) 60-18 (1527) END VIEW 46.718 (1 91) 4348 (1102) J }7/2 (89) 6-18 S43) BOTTOM SUPPLY (156) (1 ;3) AIL OPENING AA 28 20 (711) 4508) 60-1.0 (1527) I CENTER OF BASE - I .� GRAVITY BOTTOM BOTTOM RETURN '�IIC` POWER ENTRY AIR OPENING I 5- 112 (140) Da. ■ EE (�� . +.I FF 1 7(178) (158) ��\ i (168) Di 7 (178) oo roTE •- 34-78 1) 101-1/4 BASE (2572) TOP VIEW Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 34 of 52 trot ds (25) ELECTRIC INLETS BB CC Vtl-1/4 NJ OPTIONAL DISCONNECT (2521) (FACTORY INSTALLED) J 1- • 1 CONDENSATE DRAIN (FRONT) 7 41141 (119 5-38\ (1337) - -i ,,,/0 _ 19] 34-78 / 0 FORKLIFT SLOTS (GOTH SIDES) LIFTING HOLES 101-1/4 (FOR RIGGING) (886) (25721 2) SIDE VIEW 15-112_ • f L_ 1S () I (4e 1) HORIZONTAL SUPPLY AR OPENING HORIZONTAL )881UWN AIR OPENING 12 -1/8 I t= 00i (308) CONDENSATE 6.1/8 DRAIN (BACK) (156) 31 -1/2 30 (800) (162) I� -(1688 5-3/8 (137) SIDE VIEW (Horizontal Openings) Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU7 RTU10 RTU12 RTU14 / EE Package Model: LCH150S4B Description: PKGEE /12.5TON /CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL 21 -3/8 (543) OUTDOOR AIR HOOD (Furnished with Economizer or Outdoor Air Damper) EXHAUST AIR HOOD (Furnished. Field Installed) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKW ILA, WA Page 35 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 a I !il,,. Milli aoo 100 O O 001 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 • Lennox Industries Inc. - Product Submittal System ID: RTU7 RTU10 RTU12 RTU14 / EE Package Model: LCH150S4B Description: PKGEE /12.5TON /CONFIGURABLE ELECTRIC HEAT CAPACITIES Volts Input 7.5 kW 15 kW 22.5 kW 30 kW 45 kW 60 kW kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages 208 5.6 19,100 1 11.3 38,600 1 16.9 57,700 2 22.5 76,800 2 33.8 115,300 2 45.0 153,600 2 220 6.3 21,500 1 12.6 43,000 1 18.9 64,500 2 25.2 86.000 2 37.8 129,000 2 50.4 172,000 2 230 6.9 23,600 1 13.8 47,100 1 20.7 70,700 2 27.5 93,900 2 41.3 141,000 2 55.1 188,000 2 240 7.5 25,600 1 15.0 51,200 1 22.5 76,800 2 30.0 102,400 2 45.0 153,600 2 60.0 204,800 2 440 6.9 21,500 1 12.6 43,000 1 18.9 64,500 2 25.2 86,000 2 37.8 129,000 2 50.4 172,000 2 460 6.9 23,600 1 13.8 47,100 1 20.7 70,700 2 27.5 93,900 2 41.3 141,000 2 55.1 188,000 2 480 7.5 25,600 1 15.0 51,200 1 22.5 76,800 2 30.0 102.400 2 45.0 153,600 2 60.0 204.800 2 550 6.3 21,500 1 12.6 43.000 1 18.9 64,500 2 25.2 86.000 2 37.8 129,000 2 50.4 172,000 2 575 6.9 23,600 1 13.8 47.100 1 20.7 70,700 2 27.5 93,900 2 41.3 141,000 2 55.1 188.000 2 600 7.5 25,600 1 15.0 51,200 1 22.5 76.800 2 30.0 102,400 2 45.0 153,600 2 60.0 204,800 2 UNIT CLEARANCES - INCHES (MM) jOUTDOOR / i// A H0 Ot H000 00 B C D Hr _ • l \ \� it / mm Unit Clearance A B C D To Clearance in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 60 1524 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKW ILA, WA Page 36 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 • Lennox Industries Inc. - Product Submittal System ID: RTUO8 RTUO9 / EE Package Model: LCH120H4B Description: PKGEE /1OTON /CONFIGURABLE HEATING PERFORMANCE IHeat Source None COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R -410A 12.2 13.2 9900 (W) 122000 (Btuh) 118000 (Btuh) 122840 (Btuh) 116761 (Btuh) 86234 (Btuh) 80155 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 2 2 1.00 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 57.4 ( °F) 56.1 ( °F) 59.0 ( °F) 56.7 ( °F) 34.5 (lb/hr) 34.5 (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 3760 (cfm) 3760 (cfm) 0.70 (in.WC) 2.03 (hp) 3.00 (hp) CAV Belt Drive 909 (rpm) 730 (rpm) 970 (rpm) TotalStaticPress Wet Coil Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness Number Exhaust Fans ExhaustFan NomPower 1.17 (in.WC) 0.29 (in.WC) 0.03 (in.WC) 0.15 (in.WC) 4 20.0 (in.) 25.0 (in.) 2.0 (in.) 1 0.3 (hp) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 27.0 (amp) 30 (amp) 16.0 (amp) 24.7 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 4.8 (amp) 2.6 (amp) 725 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 60.1 (in.) 101.3 (in.) 46.9 (in.) 1193 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 24.0 (in.) 27.0 (in.) SOUND Outdoor Sound Rating 88 (db) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 37 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 • Lennox Industries Inc. - Product Submittal System ID: RTUO8 RTUO9 / EE Package Model: LCH120H4B Description: PKGEE /IOTON /CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre - charged Refrigeration System Expansion Valves High Capacity Driers Low Pressure Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control Units will operate cooling down to 0 degrees F ( -17.7 degrees C) without additional controls. Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GFCI - FACTORY INSTALLED /FIELD WIRED BY ELECTRICIAN STD STATIC PEF PVC DRAIN TRAP 2 IN MERV8 FILTER CIRCUIT BREAKER GLOBAL ECONOMIZER TARGET ALC -READY STANDARD CAP INCLUDED SYSTEM OPTIONS - FIELD INSTALLED H1408 2 RTU LABELING Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 38 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTUO8 RTUO9 / EE Package Model: LCH120H4B Description: PKGEE /10TON /CONFIGURABLE DIMENSIONS - INCHES (MM) Model No. CORNER WEIGHTS CENTER OF GRAVITY AA BB CC DD EE FF Base Max. Base Max. Base Max. Base Max. Base Max. Base Max. Ibs. kg Ibs. kg lbs. kg Ibs. kg Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm in. mm In. mm 092 281 127 327 148 252 114 286 130 275 125 306 139 312 142 358 162 46.51181 45.5 1156 24.5 622 25.5 648 102 282 128 329 149 254 115 287 130 276 125 308 139 314 143 360 163 46.5 1181 45.5 1156 24.5 622 25.5 648 120 294 133 340 154 264 120 297.135 283 128 318 144 321 146 372 169 46.5 1181 45.5 1156 24.5 622 25.5 648 150 304 138 350 159 273 124 306 139 293 133 327 148 332 151 383 174 46.5 1181 45.5 1156 24.5 622 25.5 648 Base Unit- The wit with NO INTERNAL OPTIONS. Max. Urit - The unit with ALL INTERNAL OPTIONS Installed. (Ecmanaer, Stardand Static Power Exhaust Fans, Controls, do). Does rot include accessories extmal to unit Or high static pave exhaust. 58-1,8 (1476) 60.38 (15271 END VIEW i 46-7/8 (1 91) 43-3/8 (1102) J 3-1/2 (89) 6-1B 5S/8 BOTTOM SUPPLY (156) (143) Atli OPENING AA 24 (610) 27 (686) 0-3/4 (273) 28 20 (721) (508) 60-2A (1527) \\\-, OF BASE BOTTOM BOTTOM RETURN */ GRAVITY POWER ENTRY AIR OPENING I 61 /2 (140)Da. + EE� \,. -, FF 7 (178) r 6S� jt (1�1 i 4 D I_ T (178) T \807102.2 pi ,- 134-7 _4. + 101.1/4 BASE (2572) TOP VIEW Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 39 of 52 1 (25) _ BB CC 119-1/4 OPTIONAL DISCONNECT (2522) (FACTORY INSTALLED) _Ed r CONDENSATE DRAIN (FRONT) 1 7 464, (179 5J /8\ (737) �o�4. L „_, ooJ ELECTRIC INLETS 34 -7'8 (886) FORKLIFT SLOTS (BOTH SIDES) LIFTING HOLES (FOR RIGGING) 101 -1(4 (2572) SIDE VIEW 15-1/2 (394) HORIZONTAL SUPPLY AR OPENING 6-1/8 056) HORIZONTAL RETURN AIR OPENING 1 l CONDENSATE DRAIN (BACK) 31-1/2 , (803) (762) 66-3/8 (1686 1) 12 -1/8 j 001 �(308)) T T 5-3/8 (137) SIDE VIEW (Horizontal Openings) Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTUO8 RTUO9 / EE Package Model: LCH120H4B Description: PKGEE /10TON /CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL 21 -318 (543) OUTDOOR AIR HOOD (Fumished with Economizer or Outdoor Air Damper) EXHAUST AIR HOOD (Furnished. Field Installed) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKW ILA, WA Page 40 of 52 - ill 0 11 II 00 o 'Il II 100 O 1 1 001 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 ' Lennox Industries Inc. - Product Submittal System ID: RTUO8 RTUO9 / EE Package Model: LCH120H4B Description: PKGEE /1OTON /CONFIGURABLE ELECTRIC HEAT CAPACITIES Volts Input 7.5 kW 15 kW 22.5 kW 30 kW 45 kW 60 kW kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages 208 5.6 19,100 1 11.3 38,600 1 16.9 57,700 2 22.5 76,800 2 33.8 115,300 2 45.0 153,600 2 220 6.3 21,500 1 12.6 43,000 1 18.9 64,500 2 25.2 86,000 2 37.8 129,000 2 50.4 172,000 2 230 6.9 23,600 1 13.8 47.100 1 20.7 70,700 2 27.5 93,900 2 41.3 141,000 2 55.1 188.000 2 240 7.5 25,600 1 15.0 51,200 1 22.6 76,800 2 30.0 102,400 2 45.0 153,600 2 60.0 204.800 2 440 6.9 21,500 1 12.6 43,000 1 18.9 64,500 2 25.2 86,000 2 37.8 129,000 2 50.4 172,000 2 460 6.9 23,600 1 13.8 47,100 1 20.7 70,700 2 27.5 93,900 2 41.3 141,000 2 55.1 188,000 2 480 7.5 25,600 1 15.0 51,200 1 22.5 76,800 2 30.0 102.400 2 45.0 153,600 2 60.0 204,800 2 550 6.3 21,500 1 12.6 43,000 1 18.9 64,500 2 252 86,000 2 37.8 129,000 2 50.4 172,000 2 575 6.9 23,600 1 13.8 47,100 1 20.7 70,700 2 27.5 93,900 2 41.3 141,000 2 55.1 188,000 2 600 7.5 25,600 1 15.0 51,200 1 22.5 76,800 2 30.0 102,400 2 45.0 153,600 2 60.0 204,800 2 UNIT CLEARANCES - INCHES (MM) //OPTIONAL • OUTDOOR AIR HOOD B G''�^% D µ``�\` \' fir, o � mm in. Unit Clearance A B C D Top p Clearance in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 60 1524 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKW ILA, WA Page 41 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU16 / EE Package Model: LCH150S4B Description: PKGEE/ 12.5TON /CONFIGURABLE HEATING PERFORMANCE Heat Source None COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R -410A 11.0 11.2 12400 (W) 144000 (Btuh) 138000 (Btuh) 140948 (Btuh) 133206 (Btuh) 100825 (Btuh) 93083 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 2 2 1.00 95.0 80.0 67.0 55.4 55.2 57.3 55.9 37.8 37.8 (in.) ( °F) ( °F) ( °F) ( °F) ( °F) ( °F) ( °F) (lb/hr) (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 4030 (cfm) 4030 (cfm) 0.80 (in.WC) 2.59 (hp) 3.00 (hp) CAV Belt Drive 1017 (rpm) 940 (rpm) 1200 (rpm) TotalStaticPress Wet Coil Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness Number Exhaust Fans ExhaustFan NomPower 1.49 (in.WC) 0.46 (in.WC) 0.04 (in.WC) 0.19 (in.WC) 4 20.0 (in.) 25.0 (in.) 2.0 (in.) 1 0.3 (hp) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 28.0 (amp) 35 (amp) 19.4 (amp) 28.5 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 4.8 (amp) 3.0 (amp) 820 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 60.1 (in.) 101.3 (in.) 46.9 (in.) 1233 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 24.0 (in.) 27.0 (in.) SOUND Outdoor Sound Rating 88 (db) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKW ILA, WA Page 42 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 - 497 -6869 ' Lennox Industries Inc. - Product Submittal System ID: RTU16 / EE Package Model: LCH150S4B Description: PKGEE /12.5TON /CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre - charged Refrigeration System Expansion Valves High Capacity Driers Low Pressure Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control Units will operate cooling down to 0 degrees F ( -17.7 degrees C) without additional controls. Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GFCI - FACTORY INSTALLED /FIELD WIRED BY ELECTRICIAN STD STATIC PEF PVC DRAIN TRAP 2 IN MERV8 FILTER CIRCUIT BREAKER GLOBAL ECONOMIZER TARGET ALC -READY STANDARD CAP INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 11408 1 RTU LABELING Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 43 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 ' Lennox Industries Inc. - Product Submittal System ID: RTU16 / EE Package Model: LCH150S4B Description: PKGEE /12.5TON /CONFIGURABLE DIMENSIONS INCHES (MM) Model No. CORNER WEIGHTS CENTER OF GRAVITY AA BB CC DD EE FF Base Max. Base Max. Base Max. Base Max. Base Max, Base Max. Ibs. kg Ibs. kg Ibs. kg Ibs. kg Ibs. kg lbs. kg Ibs. kg Ibs. kg in. mm in. mm in. mm In. mm 092 281 127 327 148 252,114 286 130 275 125 306 139 312 142 358162 46.5 1181 45.5 1156 24.5 622 25.5 648 102 282 128 329 149 254 115 287 130 276 125 308 139 314 143 360 163 46.5 1181 45.5 1156 24.5 622 25.5 648 120 294 133 340 154 264 120 297 135 283 128 318 144 321146 372 169 46.5 1181 45-5 1156!24.5 622 25.5 648 150 304 138 350 159 273 124 306 139 293 133 327 148 332 151 383 174 46.5 1181 45.5 1156 24.5 622 25.5 648 Base Unit- The snit with NO INTERNAL OPTIONS, Max. Unit - The unit with AU. INTERNAL OPTIONS Instated. (Ecman¢er, Standard Static Power Exhaust Fans, Controls, etc,). Does not include accessories extemal to unit a high static paver e>Qlaust. 58-1,6 (1476) 100 O O OOI 60.18 (1527) END VIEW 46-718 (1 91) 43-3.6 (1102) J. 3-1/2 (89) 6-1/8 5-5/8 1156) (143) BOTTOM SUPPLY AIR OPENING AA 6-18,. (156) 27 (686) 24 610) 10x4 (273) 60 -1/8 (1527) 4 */ GRAVITY BOTTOM 80170)11 RETURN POWER ENTRY AIR OPENING II S-1r21140)Da. + EE�I FF f . .r 6-se —0 i 7 (178) T CONDENSATE 28 20 (751) (sob) CENTER OF Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 44 of 52 7 (176) (168) 4D (25) ELECTRIC INLETS 15-112 (394) 34-78 _•• () 101 -114 BASE (2572) TOP VIEW BB CC V9-1/4 OPTIONAL DISCONNECT (2521) (FACTORY INSTALLED) y CONDENSATE DRAIN (FRONT) [T\7 4157 (119 I • .4 5-38\ 037) a J t I 00 34 -78 1886) FORKI_I FT SLOTS / (BOTH SIDES) LIFTING HOLES (FOR ROG84G) 101 -174 (2572) SIDE VIEW 1) SIDE VIEW (Horizontal Openings) Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972-497-6869 HORIZONTAL SUPPLY AIR HORIZONTAL OPENING RETURN AIR OPENING [T\7 1) SIDE VIEW (Horizontal Openings) Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972-497-6869 ' Lennox Industries Inc. - Product Submittal System ID: RTU16 / EE Package Model: LCH150S4B Description: PKGEE /12.5TON /CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL 1 21 -318 (543) OUTDOOR AIR HOOD (Furnished with Economizer or Outdoor Air Damper) EXHAUST AIR HOOD (Furnished. Field Installed) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 45 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 III1I - 0 II 060 'IIII 100 O t=1 001 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 ' Lennox Industries Inc. - Product Submittal System ID: RTU16 / EE Package Model: LCH150S4B Description: PKGEE/ 12.5TON /CONFIGURABLE ELECTRIC HEAT CAPACITIES Volts Input 7.5 kW 15 kW 22.5 kW 30 kW 45 kW 60 kW kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages kW Input Btuh Output No. of Stages 208 5.6 19,100 1 11.3 38,600 1 16.9 57,700 2 22.5 76,800 2 33.8 115,300 2 45.0 153,600 2 220 6.3 21,500 1 12.6 43,000 1 18.9 64,500 2 25.2 86,000 2 37.8 129,000 2 50.4 172,000 2 230 6.9 23,600 1 13.8 47,100 1 20.7 70,700 2 27.5 93,900 2 41.3 141,000 2 55.1 188,000 2 240 7.5 25,600 1 15.0 51,200 1 22.5 76.800 2 30.0 102,400 2 45.0 153,600 2 60.0 204,800 2 440 6.9 21,500 1 12.6 43,000 1 18.9 64,500 2 25.2 86,000 2 37.8 129.000 2 50.4 172.000 2 460 6.9 23,600 1 13.8 47,100 1 20.7 70,700 2 27.5 93,900 2 41.3 141,000 2 55.1 188,000 2 480 7.5 25,600 1 15.0 51,200 I 22.5 76,800 2 30.0 102,400 2 45.0 153,600 2 60.0 204,800 2 550 6.3 21,500 1 12.6 43,000 1 18.9 64,500 2 25.2 86,000 2 37.8 129,000 2 50.4 172,000 2 575 6.9 23,600 1 13.8 47,100 1 20.7 70,700 2 27.5 93,900 2 41.3 141,000 2 55.1 188,000 2 600 7.5 25,600 1 15.0 51,200 1 22.5 76,800 2 30.0 102,400 2 45.0 153,600 2 60.0 204.800 2 UNIT CLEARANCES - INCHES (MM) jOPTIONAL i// ///// OUTDOOR AR HOOD B C 4 l�\\`'N� _ �� Mall / mm Unit Clearance A B C D Top Clearance in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 60 1524 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 46 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU 18 Package Model: LGH150S4B Description: PKGGE/ 12.5TON /CONFIGURABLE HEATING PERFORMANCE Heat Source H/E LowInput WE LowOutput H/E HighInput H/E HighOutput System HeatOutput Natural Gas 156000 (Btuh) 125000 (Btuh) 240000 (Btuh) 192000 (Btuh) 192000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.75 (in.) 37.8 ( °F) 80 2 11 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R -410A 10.8 11.0 12600 (W) 144000 (Btuh) 138000 (Btuh) 145250 (Btuh) 133725 (Btuh) 111116 (Btuh) 99592 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 2 2 1.00 (in.) 95.0 ( °F) 80.0 ( °F) 67.0 ( °F) 56.7 ( °F) 56.7 ( °F) 59.2 ( °F) 57.6 ( °F) 32.2 (lb/hr) 32.2 ( lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 4700 (cfm) 4700 (cfm) 0.80 (in.WC) 3.99 (hp) 5.00 (hp) CAV Belt Drive 1174 (rpm) 1040 (rpm) 1315 (rpm) TotalStaticPress Wet Coil Static Press Gas H/E Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness Number Exhaust Fans ExhaustFan NomPower 2.03 ( in.WC) 0.58 ( in.WC) 0.36 (in.WC) 0.05 (in.WC) 0.24 (in.WC) 4 20.0 (in.) 25.0 (in.) 2.0 (in.) 1 0.3 (hp) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 31.0 (amp) 35 (amp) 19.4 (amp) 30.9 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 7.6 (amp) 2.6 (amp) 820 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 60.1 (in.) 101.3 (in.) 46.9 (in.) 1361 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 24.0 (in.) 27.0 (in.) SOUND Outdoor Sound Rating 88 (db) Project: 3000240414 TARGET # T0627 TUKW ILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 47 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972-497-6869 • Lennox Industries Inc. - Product Submittal System ID: RTU18 Package Model: LGH150S4B Description: PKGGE /12.5TON /CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre - charged Refrigeration System Expansion Valves High Capacity Driers Low Pressure Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F ( -17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on aluminized heat exchanger of 10 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GFCI - FACTORY INSTALLED /FIELD WIRED BY ELECTRICIAN STD STATIC PEF PVC DRAIN TRAP 2 IN MERV8 FILTER CIRCUIT BREAKER GLOBAL ECONOMIZER TARGET ALC -READY STANDARD CAP INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 11408 1 RTU LABELING Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKW ILA, WA Page 48 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU18 Package Model: LGH150S4B Description: PKGGE /12.5TON /CONFIGURABLE DIMENSIONS - INCHES (MM) Model No. CORNER WEIGHTS CENTER OF GRAVITY AA BB CC DD EE FF Base Max. Base Max. Base Max. Base Max. Base Max. Base Max. Ibs. kg Ibs. kg Ibs. kg Ibs. kg Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm in. mm In. mm 092 293 133 338 153 263 119 295 134 288 130 316 143 326 148 370 188 46.5 1181 45.5 1156 24.5 822 25.5 648 102 294 134 340 154 265 120 297 135 288 131 318 144 328 149 372 169 46.5 1181 45.5 1156 24.5 622 25.5 648 120 306 139 349 158 275 125 305 138 295 134 326 148 334 152 382 173 46.5 1181 45.5 1156 24.5 622 25.5 648 150 316 143 359 163 284 129 314 142 304 138 393 178 345 157 393 178 46.5 1181 45.5 1156 24.5 622 25.5 648 Base Lind - The unit with NO INTERNAL OPTIONS. Max. Unit - The unit with AU. INTERNAL OPTIONS Installed. (Economizer, Standad Static Power Exhaust Fans, Cordrds, etc.). Doe; not include accessories extemal b uritor high static power exhaust, 6.1/8 (156) AA 1 6-1/6_ 056) — 60 -1/8 (1527) BASE BOTTOM POWER ENTRY 5-1/2 (140) De. 58.118 (1476) (0o _d I=1 . 01 60-1/8 (1527) 7) END VIEW 43.3/8 (1102) J 3-1/2 189) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 49 of 52 24 (610) 27 (686) 10-3M (273) 5-68 (1433) BOTTOM SUPPLY AIR OPENING �/ 28, a0 (7)1) (508) CENTER OF 1 * BOTTOM RETURN */ GRAY (TY AIR OPENING II EE—�i I \'+:1 688 FF 7 (178) (166) . f DD 4 \BOTTOM 77a) I CONDENSATE 34.7,6 O 11 101-1/4 BASE (2572) TOP VIEW 1 (25) ELECTRIC INLETS OPTIONAL DISCONNECT (FACTORY INSTALLED) 99.1/4 (2521) J/ • CONDENSATE GRAIN (FRONT) 5318 (137) GAS SUPPLY INLET c) FLUE OUTLET / MEM 18.1/2. (470) 34 -78 .4-- (886) 39.7/8 11013) FORKLIFT SLOTS (BOTH SIDES) 00 LIFTING HOLES (FOR RIGGING) BB CC J 46-718 (1)91) 1 1014W (2572) SIDE VIEW 1540 , J 1.5/8 (394) II (4)) HORIZONTAL SUPPLY AIR HORIZONTAL OPENING RETURN AIR . OPENING 00 CONDENSATE 6-1/8 DRAIN (BAO( ,x_31 -t2_H_ 30 (800) (762) (156) 66-3/8 (1686 • 5-3/8 (137) SIDE VIEW (Horizontal Openings) 30 (762) Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal System ID: RTU18 Package Model: LGH150S4B Description: PKGGE /12.5TON /CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL 21 -318 (543) OUTDOOR AIR HOOD (Furnished with Economizer or Outdoor Air Damper) EXHAUST AIR HOOD (Furnished. Field Installed) Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 50 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 o �IIII. '1�II1 — ,0 eeo 100 O 0 001 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 w Lennox Industries Inc. - Product Submittal System ID: RTU18 Package Model: LGH150S4B Description: PKGGE /12.5TON /CONFIGURABLE UNIT CLEARANCES - INCHES (MM) //OPTIONAL OUTDOOR AIR HOOD B C / / 14 ``_ - - ei fl,lr 41 / % Unit Clearance A B C D Top Clearance in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 60 1524 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000240414 TARGET # T0627 TUKWILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 51 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 Lennox Industries Inc. - Product Submittal MISCELLANEOUS MATERIALS COMSD Third Party CDI: STANDARD 14" CURB PKG 0 ERVERS Third Party ERV: 50- R28- 51XT33 / ENERGEN 11392 TARGET EXTENDED WARRANTY - A BOX 11393 TARGET EXTENDED WARRANTY - B BOX COMSD Third Party CDI: ADAPTER CURBS PKG OF 15 FREIGHT FREIGHT Project: 3000240414 TARGET # T0627 TUKW ILA, WA Quote: 4000323816 TARGET # T0627 TUKWILA, WA Page 52 of 52 Last Changed: JANE GUNTER Prepared On: 2012 -04 -07 Phone: 972 -497 -6869 06 -03 -2013 ALEX BURKHART 727 S KENYON ST SEATTLE WA 98108 City of Tukwila Department of Community Development RE: Permit No. M12 -142 TARGET 301 STRANDER BL TUKW Dear Permit Holder: Jiro Haggerton, Mayor Jack Pace; Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 07/07/2013. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 07/07/2013, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. M12-142 6300 •outhcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431 -3670 • Fay 206 -431 -3665 1110PERMIT COOHD COP. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -142 DATE: 09/14/12 PROJECT NAME: TARGET SITE ADDRESS: 301 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPART ENTS: Public Works ❑ D(►v� P(hk/ 01, tr. • It Fire Prevention Structural Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 09/18/12 Complete, Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: ,TUES /THURS ROUTING: Please Route q, Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/16/12 Approved n Approved with Conditions g Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople Pter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name EVERGREEN REFRIGERATION LLC UBI No. 602512953 Phone 2067631744 Status Active Address 727 S Kenyon St License No. EVERGRL954R2 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 1/6/2006 State WA Expiration Date 1/6/2014 Zip 98108 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EVERGHH910J0 EVERGREEN HOME HEATING Et ENGY Construction Contractor General Unused 4/20/2009 4/20/2013 Active EVERGI'201D7 EVERGREEN REFRIGERATION INC Construction Contractor General Unused 3/27/1980 7/31/2006 Re Licensed Business Owner Information Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC Partner /Member 12/22/2005 Bond Amount PATTON, DAVID Partner /Member 01/06/2006 WA15097 PATTON, RODGER Partner /Member 01/06/2006 PATTON, MATTHEW Partner /Member 01/06/2006 TRAVELERS CAS & SURETY CO Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Merchants Bonding Co (Mutual) WA15097 01/01/2012 Until Cancelled $12,000.00 12/ 15 /2011 1 TRAVELERS CAS & SURETY CO 104667361 01/01/2006 Until Cancelled $12,000.00 01/03/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 AMERICAN FIRE AND CASUALTY COM BAW54192293 07/31/2010 07/31/2013 $1,000,000.00 07/29/2012 2 Continental Western Ins Co CWP2640663 07/31/2006 07/31/2010 $1,000,000.00 03/23/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 09/26/2012 COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WA ENERGY CODE (WSEC) SECTION 1416.3.4.2 AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.3.4.1.. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 14516.32:1. FOR WAREHOUSES SEMIHEATED SPACES AND SIMPLE SYSTEMS (AS DEFINED IN . WSEC SECTION 1421): HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.33. FOR ALL OTHER SYSTEMS: HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1416.33. NECESSARY TESTS SHALL BE IDENTIFIED PER R WSEC SECTION 1416.3.3; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION 1416.3.4.1 AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.4 SCALE : NONE • City of Tukwila BUI!..DING DIVISION, GAS PACKAGE EQUIPMENT SCHEDULE MARK ZONE TONS. MANF. MODEL SP AIRFLOW OA OA HEAT MAX RTU (E) (N) MARK TONS. LENNOX MODEL AIRFLOW OA OA WEIGHT RTU CURB TOTAL PHASE M.C.A. MO(:P NET INSTALLED CFM CFM % TYPE LBS BTUH _ - BTUH CFM CFM % LBS LBS LBS RTU -1 Sales floor 10 Carrier 48D1D012600 1989. 4715 400 80/0 GA5 1079 (N) RTU 1A, 16, 2A, 2B SEE SCHEDULE BELOW RTU -2 Sales floor 10 Carrier 48D1D012600 1989 2985 400 13% GAS 1079 (N) RTU -3 Sales floor 12.5 Carrier 48DPE014600 1989 4206 5:00 12% LAS 1680 (N) RTU -3 12.5 LGH150S4B 3,750 1,875 50 1,384 200 2,577 RTU -4 Sales floor 12.5 Carrier 48DPE014600 1989 4,606 595 12% GAS 1680 (N) RTU -4 12.5 LGH150S4B 4,700 0 0 1,384 206. 1,934 RTU -5 Sales floor 12.5 Carrier 48DPE014600 1989 3,949 440 11% GAS 1680 (N) RTU -5 12.5 LGH150S4B 3 750 1,875 50 1,384 200 2,577 RTU -6 Sales floor 12.5 Carrier 48DPE014600 1989 4,113 455 11% GAS 1680 (N) RTU -6 12.5 LGH150S4B 4,700 0 OYo 1,384. 200 1,934 RTU -7 Salim floor 12.5 Carrier 50DPE14600 1989 3,707 438 12% - 1580 (N) RTU -7 12.5 LGH150S4B 4,700 0 0% 1,336 200 1,886 1,846 RTU -8 Sales floor 12.5 Carrier 50DPE14600 1989 3,707 435 12% 1580 (N) RTU -8 10.0 LGH120H4B 3,760 0 0% 1,296 200 RTU -9 Sale/ floor : 12.5 Carrier 50DPE14600 1989 3,728 470 13% 1580 (N) (N) (N) RTU -9 RTU -10 RTU -11 10.0 12.5 12.5 LGH120H4B LGH150S4B LGH150S4B 3 760 4,700 3,750 0 500 1,875 0 % 11 50% 1,296 1,336 1,384_ 203 200 200 1,846 1,886 2,577 RTU -10 Sale/ floor 12.5 Carrier 50DPE14600 . 1989 4,013 430 12% - 1580 RTU -11 Sale/ floor 12.5 Carrier 50DPE14600 1989 4,101 406 11% GAS 1680 RTU -12 Sale/ floor 12.5 Carrier 50DPE14600AA 1989 4.169 435 11% - 1580 (N) RTU -12 12.5 LGH150S4B 4.700 0 0% 1,336 200 1,886 RTU -13 Sale/ floor 12.5 Carrier 50DPE14600AA 1989 4,100 430 10% 1580 (N) RTU -13 12.5 LGH150S4B 4,700 500 11% 1,384. 200 1,934 RTU -14 Sale/ floor 12.5 Carrier 50DPE14600AA 1989 4,700 430 9% 1580 (N) RTU -14 12.5 LGH150S4B 4,700 0 0% 1,336. 200 1,886 RTU -15 Sale/ floor 12.5 Carrier 50DPE14600 1989 5,710 400 7% GAS 1680 (N) RTU -15 12.5 LGH150S4B 4,700 0 0% 1,384 200 1,934 1,886 RTU -16 Stockroom 12.5 Carrier 50DPE14600 1989 4,030 400 10% - 1680 (N) RTU -16 12.5 LGH150S4B . 4.030 400 10% 1,336 200 RTU -17 Stockroom 10 Carrier 40010012620 1989 4000 400 10% GAS 1079 (E) RTU -17 EXISTING RTU -18 Stockroom 12 Aacom 5204- RH- 13 -3 -ED -222 1993 4,700 200 4% GAS 1805 (N) RTU -18 12.5 LGH150S4B 4,700 400 9% 1,464. 169 1.974 RTU -19 Pharmasy 2 Carrier 48GX- 02404033993 2003 660 80 9% GAS (E) RTU -19 EXISTING i REVISIONS - 7 No chances shall be made to the scope of work without prior approval of Tukwila Building Division. . `" ', oos will require a nest plan submittal i anj may Inc ude add:tianal plan review fees. FILE. COPY Permit Mo. IA I . 2.0, 14 Pier rr`►iew approval is subject to errors and omissions. or construction documents does not aphorize t4. W.7.tion of e.t.iy adopted code or ordinance. Receipt .;proved Field Copy and editions is acknowledged: /1461/1-- By Date: '1 /12 GAS PACKAGE EQUIPMENT SCHEDULE MARK MANF. MODEL TONS. AIRFLOW SP Motor COOLING HEATING ELECTRICAL WEIGHT NOTES CFM WC Hp _ TOTAL SEER EER INPUT OUTPUT AFUE . VOLTS PHASE M.C.A. MO(:P NET INSTALLED ROUND DUCT BTUH _ - BTUH BTUH ( %) (V) a BDD (A) (A) LBS RTU 1A FOOD SERVICE LENNOX LGH072H4E 6' 2,400 0.3 2 81,356 - 12.0 150,000 120,000 80% 460 30 16 25 960 1,2,3,4 RTU 1B GUEST SERVICE 103 LENNOX LGH036H4E 3 1,200 0.3 1 61,196 ---- 12:5 65,000 52,000 80% 460 30 10 15 885 " 1,2,3 RTU -2A OFFICES LENNOX LGH072H4E 6 " 2,400 0.3 2 81,356 - -- 12.0 150,000 120,000 80% 460 30 16 25 " 960 1,2,3,4 RTU -2B OFFICES LENNOX LGH072H4E 6 2,400 0.3 2 81,356 - -- 12.0 150,000 120,000 80% 460 30 16 25 960 1,2,3,4 NOTE: 1. PACKAGED ROOFTOP UNIT. 2. ALL POWER WIRING (BY E.C.) 3. PROVIDE 100% O.A. ECONOMIZER & ROOFCURB. 4. PROVIDE SMOKE DETECTOR IN MAIN RETURN DUCT (WIRING BY E.C.) City Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED SEP242012 City of Tukwila BUILDING DIVISION GENERAL NOTES DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4 "TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 6022:1. 1.4 • SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603 -10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 • INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 22 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRS PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT: 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INS1ALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5 °F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED VITHOUT.THE PRIOR VRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT VITH THE ABOVE DRAVINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EY•.I RUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SFALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMATIC"LLYWHEN THE SYSTEM IS OFF'OR'UPON POWER FAILURE, PER WSECt;EC. 1412.4.1: 6.3 AIR ECONOi NZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. 1423. MECHANICAL •CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. 0 N w 0 w 0 w 0 0 REVISIONS ITEM DRAWING DATE: 09/14/12 212014 DWG. FILE: 212014M1 OF 2 SHEETS SYMBOL LEGEND SYMBOL ABBY. DESCRIPTION DUCT SECTION SUPPLY r DUCT SECTION - RETURN /EXHAUST A RECTANGULAR DUCT ROUND DUCT FLEXIBLE DUCT MVD . MANUAL VOLUME DAMPER L a BDD BDD BACKDRAFT DAMPER MD MOTORIZED DAMPER FD ' FIRE DAMPER FSD FIRE /SMOKE DAMPER (120V POWER REQ.) -®-� ' CEILING RADIATION DAMPER sn SD SMOKE DETECTOR TQ T THERMOSTAT SENSOR R-- - - - - -R R REFRIGERANT LINES - G-- - - - - -G G NATURAL GAS LINES - CEILING DIFFUSER (SUPPLY) isi CEILING DIFFUSER (RETURN /EXHAUST) r EXHAUST FAN (CEILING MOUNTED) 1G311 INLINE FAN PROPELLER FAN' I SIDEWALL DIFFUSER -S Pr 1' 4 2012 L DUCT FITTING PE IT CE B.O,J. 12' 2'.-''41) DATUM 6 UNIT TAG .... I ili DUCT RISER REVISIONS ITEM DRAWING DATE: 09/14/12 212014 DWG. FILE: 212014M1 OF 2 SHEETS NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC - LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS DR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. `. 6 TON 6 TON. 6 TON 12.5 TON 12.5 TON 12.5 TON 10 TON 10 TON 12.5 TON 12.5 TON 12.5 TON 12.5 TON 12.5 TON REVISIONS 12.5 TON 10 TON EXISTING. 1013.5 Mechanical Equipment. Guards shall be provided where appliances, equipment, fans, roof hatch opening or other components that require service are located within 10 -. feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30- inches above the floor, roof or grade below. The guard shall be constructed so as to prevent the passage of a 21- inch - diameter sphere. The guard shall extend not less than 30- inches beyond each end of such appliances, equipment, fan or component. 1013.6 Roof Access. Guards shall be provide where the roof hatch opening is located within 10 -feet of a roof edge or open side of . a walking surface and such edge or '.open side is located more than 30-inches above the floor, roof or grade below. The guard shall be constructed so as to prevent the passage of a 21- inchdiameter sphere. DATE 12.5 TON DRAWING DATE :. 212014 DWG. FILE: 212014M2