Loading...
HomeMy WebLinkAboutPermit M12-146 - H & R BLOCKH & R BLOCK 652 STRANDER BL M12 -146 City otI'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 0005800037 652 STRANDER BL TUKW Project Name: H & R BLOCK Permit Number: M12 -146 Issue Date: 10/15/2012 Permit Expires On: 04/13/2013 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: Contractor BC PARTNERS LLC C/0 MK PROPERTY SVC LLC , PO BOX 997 98065 AL ALDRICH PO BOX 66070 , SEATTLE WA 98166 AL @NWAIRESERVICES. C OM NORTHWEST AIRE SERVICES INC. PO BOX 66070 , SEATTLE WA 981696 License No: NORTHAS963K4 Phone: 253 223 -1890 Phone: 206 241 -2657 Expiration Date: 05/24/2014 DESCRIPTION OF WORK: MINOR INTERIOR DUCTWORK ALTERATIONS OF THE EXISTING TO ACCOMMODATE THE NEW PARTITION WALL LAYOUT. Value of Mechanical: $3,065.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Fees Collected: $233.13 International Mechanical Code Edition: 2009 Permit Center Authorized Signature: Date: (0/51/ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: d‘t Print Name: div s L "7'6ez/a Date: 1�� /Z /z_ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -146 Printed: 10 -15 -2012 • • PERMIT CONDITIONS Permit No. M12-146 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -146 Printed: 10 -15 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaW A.>;ov Mechanical Per mit No. Project No. ivt I Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: X. Si"QAI..1DSC2Vb Tenant Name: 44 * R 13.10c_1!` PROPERTY OWNER Name: AL n L re..i t Name: -6C 'rag+ 1∎10a % u..e City -44M State Zip:9N426 Address: Email: Al._. A k rRES e .e5 sea44 City: c %)Np4_t.tQLmtE State: �d. Zip:. CONTACT PERSON - person receiving all project communication " Name: AL n L re..i t Address: '77D-7b City -44M State Zip:9N426 Phone: ZS3 223. /get:. 26C. .24 / - -r3I Email: Al._. A k rRES e .e5 sea44 King Co Assessor's Tax No.: ODdSOO- 00317 Suite Number: Floor: New Tenant: Yes ❑..No MECHANICAL CONTRACTOR INFORMATION• Company Name: A /612.Aws idire v)L0.. Address: p43, 25,,ox 4.kAvio City e.- 1 JE Stater, q„ Zip: ?e, K.�D/zbt Phone) :64, 2'4 /.266n" Fax: .?4l 2!`j'31“ ConNowf #4l4S463lel ExpDate:$. /z4 / /4 Tukwila Business License No.: 0992 $b% Valuation of project (contractor's bid price): $ 4d Describe the scope of work in detail: 'T%,J/642, .-N, g2, ort sak 4 /7E24 ,o NS of-ME &19 -to //e6isonoAkie *4E- ProiiticmJ 24y4.4,47 Use: Residential: New ❑ Replacement ❑ CEmmerciaa New ❑ Replacement ❑ L Fuel Type: Electric ❑ Gas ❑ Other: x 15741429 krk • H: \Applications \Forms - Applications On Line \2011 Applications \Mechanical Permit Application Revised 8 -9 -I l.docx Revised: August 201 I bh Page 1 oft Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall /floor mounted heater Appliance vent Repair or addition to headrefrig/cooling system Air handling unit <10,000 cfm Unit Type : Qt) Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial ,PEln '4-/,•J eiCs) ldmi3 6t.) Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu "PERM IT Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 h>,temational Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT 9RI ED AGENT: Signature: Print Name: , /✓i5 Mailing Address: ba 64'0470 H:\ Applications\Forms- Applications On Line \2011 Applications \Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Date: ez, zo /z Day Telephon 75 5) 273 % Seib GcJ� C'ig1kde, State Zip City Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0005800037 Address: 652 STRANDER BL TUKW Suite No: Applicant: H & R BLOCK RECEIPT Permit Number: M12 -146 Status: PENDING Applied Date: 09/26/2012 Issue Date: Receipt No.: R12 -02704 Payment Amount: $233.13 Initials: JEM Payment Date: 09/26/2012 01:09 PM User ID: 1165 Balance: $0.00 Payee: ALVIS I ALDRICH, NORTHWEST AIRE SERV TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 516290 ACCOUNT ITEM LIST: Description 233.13 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 186.50 000.345.830 46.63 Total: $233.13 doc: Receiot -06 Printed: 09 -26 -2012 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO.. - CITY OF TUKWILA BUILDING DIVISION' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 •.(206)-431- 3670. Permit Inspection Request Line (206) 431 -2451 Project: � f rt * /�J t t o C -� Typ fFlnspecti r", iU n:, Address: (0S2 n "O g(—. Date Called: Special Instructions: !h C4 3 Q 71' - O(.L . Date Wanted:/. %a:rn.- Requester: Phone Ns3 :_ r 0. ,Approved per applicable codes. Corrections required prior to approval. COMMENTS: i --; « i4 .4 If • 111El(// , SPECTION FEEIREQUIR . Prior to 'ext inspection,.fee i mustibe paid 6300 Southcenter Blvd., uite 100. Call to;schedulereinspection: Date:. O ... aA...:•,.. .,..z,,,.e,+a�...,,�.�._r.:rSaN . aaa, -. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION '6300 Southcenter Blvd., #100, Tukwila. WA 98188 .(206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: t 1 P R cs Lot IL Type of Inspection: I I -1 ni A t: .. Address: (952. GTOA.- $.1OP2 Date Called: Special Instructions: Date Wanted:. ICJ - 2 g -1 Z ::, ... _p.m: Requester: _ . . Phone No: _)521 - 2-2..3.:. i jcIC) ElApproved per applicable codes. 1fCorrections required prior to approval. COMMENTS: S (1,-\ _ pitvorr ovAe '3\ R rQ - to)1sl u'V11tS-C 7 n EINSPECTION FEE REQUIRED. Prior to next inspection;: fee must be paid/at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. =' 1413ERMIT COORD C(JPP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -146 DATE: 09/26/12 PROJECT NAME: H & R BLOCK SITE ADDRESS: 652 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued D PARTMEN S:9 B II In ivislon Public Works ❑ AVA q4..7-1� Fire Prevention E. Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 09/27/12 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route III. Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: DUE DATE: 10/25/12 REVIEWER'S INITIALS: DATE: Permit Center. Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople kilter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEt1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name NORTHWEST AIRE SERVICES INC UBI No. 602387574 Phone 2062412657 Status Active Address Po Box 66070 License No. NORTHAS963K4 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 5/24/2004 State WA Expiration Date 5/24/2014 Zip 98166 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date BEDELL, GARY E President 05/24/2004 Amount BEDELL, KYLE E Vice President 05/19/2010 01SBAAM7713 SHAW, BARBARA L Vice President 05/24/2004 05/19/2010 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 WESTERN SURETY CO 69710416 05/10/2004 Until Cancelled $12,000.00 05/24/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 7 Hartford Casualty Ins Co 01SBAAM7713 05/11/2012 05/11/2013 $1,000,000.0005 /03/2012 6 Hartford Caslns01SBAAM7713 05/11/2010 05/11/2012 $1,000,000.00 04 /08/2011 5 HARTFORD CAS INS CO 01 sba am7713 05/11/2009 05/11/2010 $2,000,000.00 04 /28/2009 4 HARTFORD CAS INS CO 01SBAAM7713 05/11/2008 05/11/2009 $2,000,000.00 04/29/2008 3 HARTFORD CASUALTY INS CO 01SBAAM7713 05/11/2006 05/11/2009 $2,000,000.00 04 /07/2008 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 10/15/2012 PROJECT GENERAL NOTES: 1 THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY. OF THE BUILDING ANDSITEWHILE THE JOB IS IN PROGRESS AND UNTIL THE WORK IS COMPLETED. 2. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES DURING THE COURSE OF THIS PROJECT. ALL OPERATIONS CONDUCTED ON THE PREMISES SHALL NOT BE OBJECTIONABLE BEYOND THE PROPERTY BOUNDARY LINES BY REASON OF NOISE, STEAM, ODOR, FUMES, GASSES, SMOKE, VIBRATION, HAZARDOUS CONDITIONS OR OTHER SUCH CAUSES. THE CONTRACTOR SHALL SECURE ALL SUCH INSPECTIONS AND FINAL APPROVALS FROM THE FIRE DEPARTMENT PRIOR TO OCCUPANCY. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. COMMENCEMENT OF THE WORK CONSITUTES ACCEPTANCE OF EXISTING CONDITIONS AS ADEQUATE FOR THE PROPER COMPLETION OF THE WORK DETAILED HEREIN. EXISTING DETAILS, ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCMENT OF WORK. IF CONDITIONS OR DETAILS DIFFER FROM THOSE SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY SO THAT APPROPRIATE MODIFICATIONS CAN BE MADE BEFORE PROCEEDING. 7. THERE SHALL BE NO DEVIATIONS FROM THE CONTRACT DOCUMENTS WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY AND HOLD URBAN SOLUTIONS STUDIO, LLC AND THE ARCHITECT HARMLESS FOR ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. THE APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKMAN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES, WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. SEE STRUCTRUAL NOTES REGARDING LUMBER GRADES, NAILING, MISCELLANEOUS STRUCTURAL STEEL, GROUTING AND ATTACHMENTS. 10. DO NOT SCALE DRAWINGS WRITTEN DIMENSIONS GOVERN. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY AND ALL DISCREPANCIES. 11. ALL DIMENSIONAS ARE TO THE CENTERLINE OF COLUMN, FACE OF STUD, CENTERLINE OF STUD OR FACE OF CMU — UNLESS OTHERWISE NOTED. 12. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME FOR OTHER SIMILAR WORK. 13. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST RECOMMENDATIONS OF WRITTEN DIRECTIONS. 14. FIRE EXTINGUISHERS: VERIFY REQUIREMENTS AND LOCATION WITH FIRE MARSHALL. FIRE EXTINGUISHER LOCATIONS SHALL NOT BE BLOCKED OR HIDDEN BY PRODUCT DISPLAYS, .DECOR FIXTURES OR ANY SUCH SIMILAR MATERIALS. 15. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 16. EXIT DOORS, EXIT LIGHTS AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL, DECOR OR FURNISHINGS. 17. FINISH FLOOR, TOP OF CONCRETE SLAB, DATUM = +0.00'. 18. ALL WOOD MEMBERS IN CONTACT WITH CONCRETE SHALL BE PRESSURE - TREATED. 19. REFLECTED CEILING PLANS ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR. EXACT LOCATIONS OF LIGHTING. FIXTURES AND CEILING MATERIALS SHOULD BE CONFIRMED PRIOR TO INSTALLATION. 20. PROVIDE SEISMIC BRACING AT ALL SUSPENDED ACOUSTICAL CEILING AREAS @ 12' O.C. IN BOTH DIRECTIONS. 21. THE CONTRACTOR SHALL VERIFY ALL WINDOW AND DOOR ROUGH OPENING REQUIREMENTS WITH DOOR AND WINDOW MANUFACTURERS PRIOR TO INSTALLATION. 22. EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATION, BETWEEN WALLS AND ROOF AND OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS AND DOORS, AND ALL OTHER SUCH OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED. GASKETED OR WEATHER- STRIPPED TO LIMIT AIR LEAKAGE AND PROHIBIT WATER PENETRATION. 23. ALL TEARS AND JOINTS IN BATT INSULATION TO BE SEALED WITH MANUFACTURER- APPROVED METHODS. 24. PLUMBING, ELECTRICAL AND HVAC SYSTEMS ARE BIDDER - DESIGNED AND COVERED UNDER SEPARATE PERMIT. CONTRACTOR SHALL SUBMIT BIDDER- DESIGN DRAWINGS TO ARCHITECT FOR REVIEW PRIOR TO FABRICATION AND INSTALLATION. SITE DATA: PROJECT ADDRESS: CURRENT ZONING: PARCEL NUMBER: PROJECT TEAM: BUILDING OWNER: TENANT: ARCHITECTURAL: GENERAL CONTRACTOR: WORK DESCRIPTION: OCCUPANCY CONSTRUCTION TYPE PARKING PROVIDED VALUATION OF WORK. 644 STRANDER BLVD. TUKWILA WA 98188 TUC (CITY OF TUKWILA) 000580 -0037 BC PARTNERS LLC C/O MK PROPERTY SERVICES SNOQUALMIE, WA 98065 425- 888 -2993 H &R BLOCK urban solutions studio, IIc 1555 UNION AVE NE, #66 RENTON WA 98059 425- 922 -1474 CONTACT: GARY B. BARBER, AIA gary. barber @urbansolutionsstudio.com EDI 12920 S.E. 95th Way NEWCASTLE WA 98056 425- 255 -5467 CONTACT: CHUCK LINDBERG INTERIOR TENANT IMPROVMENT TO EXISTING VACANT 2,165 S.F. STOREFRONT SPACE. NO EXTERIOR MODIFICATIONS TO THE BUILDING SHELL ARE PLANNED UNDER THIS SUBMITTAL. SIGN PERMIT WILL BE UNDER A SEPARATE SUBMITTAL. B (2009 IBC) V -N SPRINKLERED EXISTING PARKING UNCHANGED $ 51,000 LEGAL DESCRIPTION: MEADER HENRY D -C #46 LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 84 -31 -SS RECORDING NO 8501030748 SD SHORT PLAT DAF - POR NW 1/4 OF SEC 25 -23 -04 -BAAP ON WLY R/W LN OF WEST VALLEY HWY SR 181 AT A PT WCH BEARS S 81 -07 -31 W 50 FT FR C/L THOF AT HWY ENGR STA 160+00 TH FR SD POB ALG SD WLY R/W LN S 12 -18 -30 E 250.45 FT TAP WCH BEARS S 81 -07 -31 W 35 FT FR C/L AT HWY ENGR STA 162 +50 TH S 05 -15 -06 E 112.35 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO RGT RAD 50 FT & A C/A OF 86 -22 -37 ARC LENGTH 75.38 FT TAP ON NLY RNV LN OF STRANDER BLVD TH ALG SD NLY RNV LN TANGENT TO PRECEDING CURVE S 81 -07 -31 W 28.58 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO LFT RAD 700 FT & C/A OF 19 -33 -22 ARC LENGTH 238.92 FT TH TANGENT TO PRECEDING CURVE S 61 -34 -09 W TO INTSN OF SD NLY R/W LN OF STRANDER BLVD WITH ELY BANK OF GREEN RIVER TH NLY ALG SD ELY BANK TO INTSN WITH SLY LN OF BOW LAKE P/L R/W 30 FT WIDE TH ALG SD SLY LNS S 87 -12-48 E 194.01 FT TAP ON WLY RNV LN OF SD WEST VALLEY HWY TH ALG SD WLY R/W LN S 08 -52 -29 E 165.06 FT TO POB SHEET INDEX: A -1 COVER SHEET m -1 OAR FLOOR PLAN A -3 REFLECTED CEILING PLAN TO I -90 NTERURBAN 1.1 VES Gi1P%` SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical aj Electrical tgl Plumbing tir Gas Piping City of Tukwila TO HWY 167 TU \ ILA SOUTHCENTER BLVD TUKWILA PARKWAY_ 1- w cc O W ce a cr w STRANDER BLVD GREEN RIVER VICINITY MAP SCALE: 1" - 1000' -0" 500' 1000' NORTH REV!St0NS No changes sh b ame de to the scope d of work without prior approval ukwila Bt �ildin . n. of i r°� � , o�jts;on � � Division. �r wul require a new plan submittal :,:] may i vI s � additional plan review f ee. r Permit No. Copy Plan review approval is subject to errors and omission. Approval of Construction documents does not authorize the violation of any adopted code or ordinance. Receipt el a p p r o v e d Meld C o p y a n d } '' :�S` is acknowledged: By City Of Tukwila CUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 3 2012 City of u ila BUILDIN r (VISION XISTIN BUILDING LINE SITE PLAN SCALE: 1" = 40' -0" 20' 40' • ■ • ■ NORTH M 12- cmniik SEP 2 6 2012 PERMIT CENTER LO N M cip U wc�co -J oC p1 __I w ¢ z c� tzi ()ZS LI, N = Oti2 INTERIOR TENANT IMPROVEMENT z uni X ce a z z H 0 11 w t-- z SHEET: Mechanical Cover Sheet Q DATE REMARKS BY - - 1 4-- PERMIT SUBMITTAL - 1 1 1 - -I 1 1 1 PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THIS DRAWING DRAWN BY: CHECKED BY: JOB #: DATE: 9/5/12 SHEET #: A1.0 Scope of Work Per Sheet M -1 Minor, interior only, ductwork alterations of the existing HVAC system as required accommodating the new partition wall layout. HVAC General Notes: Codes Alterations of the existing mechanical system shall be per the most current applicable building, mechanical, energy and fire codes, and regulations, as adapted by the City. of Tukwila. Insulation/Lining /Sealant Notes As a minimum, comply with the thickness and types listed in the energy code enforced by the City of Tukwila. Balance and Commissioning Commissioning and Completion Documents to be in compliance with 2009 Washington State Energy Code, Section 1416. Occupancy Air Volume Minimum Occupancy air volumes per 2009 International Mechanical Code, Table 403.3, for Type Group "B" Occupancy. System design @ .06 CFM per square foot. Total space square footage = 2,165 2165x.06= 130 CFM Occupancy Air provided via air side economizer set at the minimum open position. Sheet Metal Notes Reference: SMACNA HVAC Duct Construction Standards, Metal and Flexible, Current Edition. Volume Dampers Provide an accessible, lockable, manual air volume control damper for each relocated supply or return air opening if none exist. Thermostat Leave As/Is at the existing location. HVAC LEGEND SUPPLY AIR RETURN AIR OR CROSSOVER DUCT VOLUME DAMPER THERMOSTAT FLEXIBLE DUCT SHEETMETAL DUCT REVIEWED FOR CODE COMPLIANCE APPROVED te' 1 -u 'i 0- e066 cU Etz 'bu u dfl E- 15-41'02.15 401 ' tf 1t pirr.ota_ -1-c› uia l% =,JSka1'I NL (Dti� "Re40.at,1 icz L'ec s oU'Erz t x.4 c* E:.;- ',Jl (31)1g M:l 11,016 ‘,' e✓ca toe Belt N e / oM OD44E N Cie) (.ate �. X X Meg 1 .. EIR E/R 640 X E/R E/R EIR R N '1 1 =4....15,%1i Al el+, SnO oven. ri x,c4 `i2 EIR EIR Au Me., LiA c EIR EIR EIR EIR X EIR X E/R E/R X EIR `kElocA+-E IZ`'i n A vz. 1)tic-Vu,I.Eas 4 da‘D AQE'A. q-' b./ IDE 4.1 t Cam. t 1 lc-, s REFLECTED CEILING PLAN h4VE 4s crTMEaTratiLA SEP 7 6 2012 PERMCTCENiER REF. NORTH 00 CO CO 1- w N W; o M H W oc w 00 U z f- c8 LI_ r :R OZS LL Ln = d- z '` t; 4 1- Z w > a O to Ce U- X u 1-4 in ko Z N w t7 F- z O M w w z < o rA 4‹• k14 1;1 O � U •� U re w ►w- 0 PERMIT SUBMITTAL 1- 63 e z w 0 W= 0 w H- p: z z0. w 1 'di- 0.1 CD a DRAWN BY: CHECKED BY: JOB #: PHASE: DATE:., 9/5/12 SHEET #: DOOR SCHEDULE # DOOR FRAME FINISH NEW/ EXIST'G. HARDWARE NOTES SIZE MAT'L. MAT'L. 1 3/0 X 7/0 STOREFRONT ALUM. ALUM. FACT. (E) EXISTG. EXISTG. 2 3/0 X 7/0 FLUSH STEEL STEEL PAINT (E) EXIST'G. EXISTG. 3 .3/0 X 7/0 FLUSH SC WD. EXISTG. STAIN (E) EXISTG. EXISTG. 4 3/0 X 7/0 FLUSH SC WD. EXISTG. STAIN (E) EXIST'G. EXISTG. 5 10/0 X 9/0 OVERHEAD STEEL STEEL FACT. (E) EXIST'G. EXISTG. CO 6 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 1 7 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 1 8 3/0 X 7/0 FLUSH SC WD. . WOOD STAIN NEW GROUP 1 9 310 X 7/0 FLUSH SC WD. • WOOD STAIN NEW GROUP 1 10 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 2 11 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 3 HARDWARE GROUPS: NOTES KEY: IN PLACE - GC TO SECURE DOOR FROM THE FILL ANY GAPS TO ENSURE WEATHER - TIGHTNESS OF GROUP 1 GROUP 3 1O DOOR TO BE ABANDONED INTERIOR AND BUILDING ENVELOPE. 1 1/2 PAIR PRIVACY (LEVER -TYPE) SILENCERS GROUP 2 BUTTS 1 1/2 PAIR BUTTS LATCHSET PASSAGE LATCHSET OVERHEAD CLOSER SILENCERS DEADBOLT BUTTS LATCHSET 1 1/2 PAIR PASSAGE SILENCERS EXISTING TOILET ROOMS TO REMAIN - CLEAN AND PAINT WALLS ONLY NO ALTERATIONS 1 WALL TYPE KEY D EXISTING WALL TO REMAIN PATCH AND PAINT AS REQUIRED FOR UNIFORM FINISH FULL HGT TO UNDERSIDE OF T -BAR CEILING - 5/8" GWB 2 X 4 STUDS @ 16" O.C. 5/8" GWB FULL HGT TO UNDERSIDE OF ROOF STRUCTURE - 5/8" GWB 2X4 STUDS @16 "O.C. 5/8" GWB FURRING @ EXTERIOR WALL (CONCEAL OVERHEAD DOOR) - 2 X TREATED STUDS @ 24" O.C. FILL ALL STUD CAVITIES WITH FACED INSULATION BATTS 5/8" GWB 11' -9" ROOM FINISH SCHEDULE NO. ROOM WALLS NORTH SOUTH EAST WEST FLOOR CEILING BASE NOTES 100 101 102 103 104 105 106 107 108 109 110 LOBBY CONFERENCE OPEN OFFICE OFFICE OFFICE OFFICE STORAGE BREAK ROOM' HALL TOILET TOILET (ACCESSIBLE) P 1 P 1 P 3 P 1 P 2 P 1 P 2 P 1 P 1 P 1 P 1 P 1 P4 P 1 P 1 P 1 P 1 P1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 4 P 1 P 1 P 1 P 1 P 1 P4 P4 P4 P4 P 1 P 1 P 1 P4 P4 P4 C1 /C4 C1 C1 C1 C1 C1 NIC NIC C1 EXIST. EXIST. EXIST. ACT EXIST. ACT EXIST. ACT EXIST. ACT EXIST. ACT EXIST. ACT EXIST. ACT EXIST. ACT EXIST. ACT EXIST. GWB EXIST. GWB ww w m m m to it w z o z O co md. PAINT KEY: P1 - GLIDDEN / ICI #A1822 DESERT CASTLE PRIMER -1 COAT GLIDDEN HIGH -HIDE PRIMER 1000 -1200 FINISH - 2 COATS FINISH PAINT IN GLIDDEN ULTRAHIDE 250, 1420N SERIES EGSHELL FINISH P2 - GLIDDEN / ICI #A0574 OAKLEY BROWN PRIMER - 1 COAT GLIDDEN HIGH -HIDE PRIMER 1000 -1200 (TINTED) FINISH - 2 COATS FINISH PAINT IN GLIDDEN ULTRAHIDE 250, 1420N SERIES EGSHELL FINISH P3 - GLIDDEN / ICI #A1048 BLADE PRIMER -1 COAT GLIDDEN HIGH -HIDE PRIMER 1000 -1200 FINISH - 2 COATS FINISH PAINT IN GLIDDEN ULTRAHIDE 250; 1420N SERIES EGSHELL FINISH P4 - GLIDDEN / ICI #A1964 SHADOW PLAY PRIMER -1 COAT GLIDDEN HIGH -HIDE PRIMER 1000 -1200 (TINTED) FINISH - 2 COATS FINISH PAINT IN GLIDDEN ULTRAHIDE 250, 1420N SERIES EGSHELL FINISH FLOORING KEY: C1 - INTERFACE FLOR 1465202500 TO SCALE COLOR #7769 FOUNDATION * *CARPET TILES TO BE INSTALLED IN RANDOM PATTERN ** C4 - INTERFACE ENTRY TILE 129017191 COLOR #7191 OLIVE T1 JOHNSONITE: VCTAZ -V603 BUFF CORTINA COLORS - AZROCK.SUPPLIED BY H &R BLOCK (WHERE SHEET VINYL REQ'D. BY CODE, USE JOHNSONITE MELODIA - #620 BEACHFRONT) TOIL - -- 11101 `.ACCE DEMO EXISTING WALL - RELOC. TELEPHONE BD. TO NEW WALL 0 EXISTING ELECTRICAL PANEL (TO REMAIN; r EXISTING OVERHEAD DOOR AND TRACK 70 REMAIN IN PLACE J UNISEX TOILET HALL 108 107 '•I .dam „��../r...r�. .r.z STORAGE D 11061 OFFICE 104 F-31 OFFICE 103 0 OPEN OFFICE 102 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 3 2012 City of Tukwila BUILDING DIVISION CD CONFERENCE 101 LOBBY 100 e 23' -2" EXISTING (FIELD VERIFY) 10' -8” 15'-4" 12' -0" 63' -4" EXISTING (FIELD VERIFY) FLOOR PLAN SCALE: 1/4" -1' -0" M 12- CITY " V SEP 2 6 2012 PERMITCENTER LA REF. NORTH L 1 co co T-1 0 M 4 CC1 Wo U Z ce 1E4 }.4, u_. c, =O INTERIOR TENANT IMPROVEMENT AN INTERIOR TENANT IMPROVMENT TO AN EXISTING 2,165 S.F. SPACE DATE REMARKS BY -1-4- PERMIT SUBMITTAL - I I I I- PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THIS DRAWING . 1 1 1 DRAWN BY: GBB CHECKED BY: JOB #: PHASE: DATE:. 9/5/12 SHEET #: A2.0 1