Loading...
HomeMy WebLinkAboutPermit M12-152 - INTERNAPINTERNAP 3355 S 120 PL M12 -152 City' IPTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 1023049082 3355 S 120 PL TUKW Project Name: INTERNAP Permit Number: M12 -152 Issue Date: 11/01/2012 Permit Expires On: 04/30/2013 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD , 4TH FLOOR 98168 Contact Person: Name: Address: Email: JENNIFER NELSON 1221 SECOND AV N , KENT WA 98032 JEN.NELS ON @HERMANS ON. C OM Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N , KENT, WA 98032 Contractor License No: HERMACLOO5BJ Phone: 206 - 575 -9700 Phone: 206 - 575 -9700 Expiration Date: 08/25/2014 DESCRIPTION OF WORK: PROVIDE AND INSTALL (2) COOK SQN -B 14,000 CFM EXHAUST FANS, (2) l Ohp ABB VFD'S. (1) 8' X 8' OUTSIDE AIR MOTORIZED DAMPER. RELOCATE AC -1 AND AC -2 CONDENSATE PIPING AND ELECTRICAL DISCONNECT TO MAKE ROOM FOR THE NEW DAMPER. TAP INTO AN EXISTING DOMESTIC WATER LINE AND EXTEND IT TO THE CONDENSATE TANK LOCATION. Value of Mechanical: $15,900.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie xami with, The granting of this permit does not pre construction or the performance of work. back of this permit. Fees Collected: International Mechanical Code Edition: $379.56 2009 Date: 1t l c i t a ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit and agree to the conditions on the Signature: Print Name: K� rs t--e n F (J( Date: 11 ` / /i -2- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -152 Printed: 11 -01 -2012 PERMIT CONDITIONS Permit No. M12-152 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -152 Printed: 11 -01 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. ‘I 'l\ 1 SZ Project No. Date Application Accepted: (61--- Ll -- ( ) Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION King Co Assessor's Tax No.: 102304 -9082 Site Address: 3355 S 120th Place Tenant Name: Internap Suite Number: PROPERTY OWNER Name: Jennifer Nelson Name: Sabey City: Kent State: Wa Zip: 98032 Address: 3355 S 120TH PLACE Email: jen.nelson @hermanson.com City: TUKWILA State: WA Zip: 98168 CONTACT PERSON - person receiving all project communication Name: Jennifer Nelson Address: 1221 2nd AVE North City: Kent State: Wa Zip: 98032 Phone: (206) 575 -9700 Fax: (205) 575 -9800 Email: jen.nelson @hermanson.com New Tenant: Floor: 1 ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Company Address: 1221 2nd AVE North City: Kent State: WA Zip: 98032 Phone: (206) 575 -9700 Fax: (206) 575 -9800 Contr Reg No.: HERMACLOO5BJ Exp Date: 08/25/2014 Tukwila Business License No.: 09 -459 Valuation of project (contractor's bid price): $ 15,900 Describe the scope of work in detail: Provide and install (2) Cook SQN -B 14,000 CFM exhaust fans, (2) 1Ohp ABB VFD's, (1) 8' x 8' outside air motorized damper. Relocate AC — 1 and AC - 2 condensate piping and electrical disconnect to make room for the new damper, Tap into an existing domestic water line and extend it to the condensate tank location. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas ❑ Other: H: \Applications \Forms - Applications On Line \201 I Apphcations \Mechanical Permit Application Revised 8 -9 -1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended /wall /floor mounted heater 2 Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct 2 Ventilation system Hood and duct Incinerator — domestic Incinerator — conun/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN a NER Q'�AUTHQRIZJD AGENT: Signature: Print Name: NIF " NELSON Mailing Address: 1221 2ND AVE NORTH H: \Applications \Farms - Applications On Line \2011 Applications \Mechanical Permit Application Revised 8 -9 -I I.docx Revised: August 2011 bh Date: 10/02/2012 Day Telephone: (206) 575 -9700 KENT WA 98032 City State Zip Page 2 of 2 • J��,Ii�A wq City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: Applicant: INTERNAP RECEIPT Permit Number: M12 -152 Status: PENDING Applied Date: 10/04/2012 Issue Date: Receipt No.: R12 -02764 Payment Amount: $379.56 Initials: WER Payment Date: 10/04/2012 08:43 AM User ID: 1655 Balance: $0.00 Payee: KIRSTIN FAUSKO TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 01402G ACCOUNT ITEM LIST: Description 379.56 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 303.65 000.345.830 75.91 Total: $379.56 doc: Receipt -06 Printed: 10 -04 -2012 Mil -iS2- 4:r-1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 vi'114_(206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Type�°f Inspection: n Addrres g5 ' p� Date Called: ,A./ D k_ 4 o Ll G ( --�-- " Special Instructions: I" 0 jie yOr— ,, .' u-J dl r-,_ _r can Date Wanted:. ` br . �1) p.m. Requester -- 6A/ Phoprolo ( !j Approved per applicable codes. Corrections required prior to approval. COMMENTS: 06(08 -(;e4 -0l D .. ,S k i.7t- "'J v ,A./ D k_ 4 o Ll G ( --�-- " Inspeitpr: Date:3 _ n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 03 -05 -2013 JENNIFER NELSON 1221 SECOND AV N KENT WA 98032 11fl d s ger�ton, AY i) or artn2ent Of C,ommun* Development YackPrce, Director RE: Permit No. M12 -152 INTERNAP 3355 S 120 PL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 04/30/2013. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 04/30/2013, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ennif Marshall rmit echnician File: Permit File No. M12-152 6300 Sgutheenter Boulet.ard; Suite: #100, Tz la, Washington 98188 • Phone 2p 431 3670 p4:2-0.6=434-1,:w5 PERMIT C PLAN REVIE PY UTING SLIP ACTIVITY NUMBER: M12 -152 PROJECT NAME: INTERNAP SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Correction Letter # DATE: 10 -03 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: IA ID Bang ivis on Fire Prevention II Public Works Structural ❑ Planning Division Permit Coordinator w DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-09-12 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route IV Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 11 -06-12 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pr ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HERMANSON COMPANY LLP UBI No. 602004844 Phone 2065759700 Status Active Address 1221 2Nd Ave N License No. HERMACLOO5BJ Suite /Apt. License Type Construction Contractor City Kent Effective Date 1/11/2000 State WA Expiration Date 8/25/2014 Zip 980322945 Suspend Date County King Specialty 1 General Business Type Limited Liability Partnership Specialty 2 Unused Parent Company License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HERMAC'016RN HERMANSON CORPORATION Construction Contractor General Unused 1/11/2000 8/21 /2002 Archived HERMAC *217NT HERMANSON CORPORATION Construction Contractor Air Heat,Ventilation,Evaporat Metal Fabrication 8/30/1979 8/21/2000 Archived Business Owner Information Name Role Effective Date Expiration Date NICOLAISEN, KNUT H Partner /Member 08/05/2010 Amount BROCK, DANIEL L Partner /Member 08/05/2010 GL0370326109 FOX, DEAN M Partner /Member 08/05/2010 HENGEL, STEPHEN A - Partner /Member 08/05/2010 American Zurich Insurance Comp DYCKMAN, KENNETH A Partner /Member 08/05/2010 ROBINETT, PAUL J Partner /Member 08/05/2010 9 HERMANSON, RICHARD L Partner /Member 01/01/1980 08/21/2011 ALMON, KEVIN Partner /Member 01/01/1980 08/05/2010 MACDONALD, JAMES Partner /Member 01/01/1980 08/05/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 WESTERN SURETY CO 929381801 01/01/2006 Until Cancelled $12,000.00 12/01/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 11 American Zurich Insurance Comp GL0370326109 08/21/2012 08/21/2013 $1,000,000.00 08/14/2012 10 American Zurich Insurance Comp GL0370326108 08/21/2011 08/21/2012 $1,000,000.00 08/18/2011 9 American Zurich Ins Co GL0370326107 08/21/2010 08/21/2011 $1,000,000.00 08/18/2010 8 ZURICH AMERICAN INS CO GL0370326106 08/21/2008 08/21/2010 $1,000,000.00 08 /24/2009 7 08/21/2004 08/21/2008 $1,000,000.00 08/20/2007 https: // fortress .wa.gov /lni/bbip/Print.aspx 11/01/2012 loco GO A AC ACH ACT AD ADD'L AFF AFG AHU ALUM AMP /AMPS AP ARCH BC BDD BF BHP BLDG BOD BOP BOT BS BTU BTUH CAP CC CD CDWR CDWS CFM CHWR CHWS CLG COL CONC COND CONN CONT CONTR COORD COP CT CU CW DB DBA DDC DEFL DEG DG DIA DMPR DN DT DWG EXH EA EAT EC EER EF EFF EL ELEC /ELECT EP EMCS ENT EQUIP ESP EWT EXIST F FAC FD FDC FF FIC FIO FLA FLEX FLR FOB FOIC FOS FOT FP FPM FSD FT FUT FV G GA GALV GC GEN GPM GR GRD GWB HD HORIZ HP HR HSPF HT HWTG HWR HWS HX MECHANICAL ABBREVIATIONS AMPS AIR CONDITIONING AIR CHANGES PER HOUR ACOUSTICAL TILE CEILING ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM AMPERAGE ACCESS PANEL ARCHITECT BEADED COLLAR BACKDRAFT DAMPER BELOW FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BIRD SCREEN BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CONTROLS CONTRACTOR CEILING DIFFUSER /CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING COLUMN CONCRETE CONDENSATE CONNECT /CONNECTED /CONNECTION CONTINUOUS /CONTINUATION CONTRACTOR COORDINATE COEFFICIENT OF PERFORMANCE COOLING TOWER CUBIC /CONDENSER UNIT DOMESTIC COLD WATER /CONDENSER WATER DUCTBOARD /DRY BULB DECIBEL DIRECT DIGITAL CONTROL DEFLECTION DEGREE/ DEGREES MODULAR DIFFUSER (GWB CEILING) DIAMETER DAMPER DOWN MODULAR DIFFUSER ("T -BAR" CEILING) DRAWING EXHAUST EACH ENTERING AIR TEMPERATURE EGGCRATE GRILLE /END CAP /ELEC CONTRACTOR ENERGY EFFICIENT RATING EXHAUST FAN EFFICIENCY ELEVATION ELECTRICAL /ELECTRIC END PLUG ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING FAHRENHEIT FIRE ALARM CONTRACTOR FIRE DAMPER FIRE DEPARTMENT CONNECTION FINISHED FLOOR FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FULL LOAD AMPS FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OTHERS. INSTALLED FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FIRE /SMOKE DAMPER FOOT /FEET FUTURE FACE VELOCITY GRILLE GAUGE /GALLON GALVANIZED GENERAL CONTRACTOR GENERAL GALLONS PER MINUTE GRILLE GRILLE /REGISTER /DIFFUSER GYPSUM WALL BOARD HEAD HORIZONTAL HORSEPOWER HOUR HEATING SEASONAL PERFORMANCE FACTOR HEIGHT HIGH WALL TRANSFER GRILLE HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER BY CONTRACTOR HZ BC CW D E MC N N WG PLV KW HERTZ NTERNATIONAL BUILDING CODE NDUSTRIAL COLD WATER NSIDE DIAMETER /DIMENSION NVERT ELEVATION NTERNATIONAL MECHANICAL CODE NCHES NCHES WATER GAUGE NTEGRATED PART LOAD VALUE KILOWATTS LAT LEAVING AIR TEMPERATURE LB /LBS POUND /POUNDS LD /LIN DIFF LINEAR DIFFUSER LF /LIN FT LINEAL FOOT /FEET LPG LIQUID PROPANE GAS LVG LEAVING LWA SOUND POWER LWG LOW WALL GRILLE LWR LOW WALL REGISTER LWT LEAVING WATER TEMPERATURE MAX MAXIMUM MAU MAKE UP AIR UNIT MBH 1000 BRITISH THERMAL UNITS MCA MINIMUM CIRCUIT AMPACITY MD MOTORIZED DAMPER MFR MANUFACTURER MISC MISCELLANEOUS MIN MINIMUM /MINUTE MT MOUNT MTD MOUNTED MUW MAKE -UP WATER N/A NOT APPLICABLE NC NORMALLY CLOSED /NOISE CRITERIA NG /NGAS NATURAL GAS NIC NOT IN CONTRACT NO NORMALLY OPEN /NUMBER NPW NON- POTABLE WATER N -R NON- RESIDENTIAL OA /OSA OUTSIDE AIR OB OPPOSED BLADE OBD OPPOSED BLADE DAMPER OD OUTSIDE DIAMETER /DIMENSION P PUMP PCF POUNDS PER CUBIC FOOT PD PRESSURE DROP PH PHASE POC POINT OF CONNECTION PRESS PRESSURE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE QTY QUANITY R RETURN GRILLE /RELOCATED /RETURN RA RETURN AIR RD /RND ROUND REF REFERENCE REG REGISTER REQ REQUIRED RESID RESIDENTIAL RF RELIEF RG RETURN GRILLE RL REFRIGERANT LIQUID RPM REVOLUTIONS PER MINUTE RS REFRIGERANT SUCTION S SUPPLY SA SUPPLY AIR SAT SATURATION SD SMOKE DETECTOR S/D SLIP & DRIVE CONNECTION SEER SEASONAL ENERGY EFFICIENCY. RATING SENS SENSIBLE SG SUPPLY GRILLE SL SOUND LINED SM SPIRALMATE /SHEETMETAL SPEC SPECIFICATION SO SCREENED OPENING SOG SLAB ON GRADE SP STATIC PRESSURE SQ FT SQUARE FEET SR SIDE WALL REGISTER SS STAINLESS STEEL STRUC STRUCTURAL T TRANSFER TA TRANSFER AIR TEMP TEMPERATURE/TEMPORARY TBD TO BE DETERMINED TG TRANSFER GRILLE TOC TOP OF CONCRETE /CURB TOD TOP OF DUCT TOS TOP OF STEEL /TOP OF SLAB TOT TOTAL TSP TOTAL STATIC PRESSURE TSTAT THERMOSTAT TYP TYPICAL UH UNIT HEATER UNO UNLESS NOTED OTHERWISE V VOLT VIAQC VENT. AND INDOOR AIR QUALITY CODE VD VOLUME DAMPER VEL VELOCITY VERT VERTICAL VFD VARIABLE FREQUENCY DRIVE VOL VOLUME W WALL /WALLS, WRAPPED DUCT WB WET BULB WG WATER GAUGE W/ WITH W/O WITHOUT W /SF WATTS PER SQUARE FOOT WSEC WASHINGTON STATE ENERGY CODE MECHANICAL LEGEND ,10X10® t10X10/ b 10O)) 100 RECTANGULAR SUPPLY AIR DUCT - TURNING UP OR TOWARD RECTANGULAR SUPPLY AIR DUCT - TURNING DOWN OR AWAY RECTANGULAR EXHAUST OR RETURN AIR DUCT - TURNING UP OR TOWARD RECTANGULAR EXHAUST OR RETURN AIR DUCT - TURNING DOWN OR AWAY ROUND DUCT - TURNING UP OR TOWARD ROUND DUCT - TURNING DOWN OR AWAY FLATOVAL DUCT - TURNING UP OR TOWARD FLATOVAL DUCT - TURNING DOWN OR AWAY 100 $� DUCT OVERLAP 100 T. a 100 -� e 11 f VVVVV't -Ar> { f 1===•1 6X16SL -16Xi 6DB %maw E:1)° z z 45' TAP VOLUME DAMPER CHANGE OF ELEVATION RISE(R) DROP(D) TRANSITION TURNING VANES/SPUTTERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW DIRECTION FORCED NR) AIR FLOW DIRECTION (DRAWN AIR) MOTOR OPERATED DAMPER FLEX CONNECTION SMOKE DAMPER FIRE DAMPER COMBINATION FIRE & SMOKE DAMPER SOUND TRAP ACCESS DOORS ACOUSTICALLY LINED DUCT (SOUND LINED) DUCT BOARD FABRIC DUCT VAV BOX CEILING SUPPLY AIR DIFFUSER (SHOWN WITH REDIRECTED AIR CORE) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE SLOTTED DIFFUSER (PLAN VIEW) REVISION CLOUD & TRIANGLE ROUND DUCT SYMBOL O FLATOVAL DUCT SYMBOL DEGREES SYMBOL POINT OF CONNECTION GRD TAG IDENTIFIER = TYPE -CFM SIZE THERMOSTAT /TEMPERATURE SENSOR HUMIDITY SENSOR SMOKE DETECTOR STATIC PRESSURE SENSOR CD1 -100 80 EXISTING DUCTWORK DEMO DUCTWORK WALL - MOUNTED GRILLE o PIPE ELBOW UP • PIPE ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE DOWN PLUG OR CAP GAS PRESSURE REDUCING ASSEMBLY SOLENOID VALVE PUMP CHILLED WATER SUPPLY CHILLED WATER RETURN REFRIGERANT LIQUID REFRIGERANT SUCTION NATURAL GAS LIQUID PROPANE GAS CONDENSER WATER SUPPLY CONDENSER WATER RETURN HEATING WATER SUPPLY HEATING WATER RETURN CONDENSATE z 2 ��a z � CHWS CHWR --s : RL s t-- RS s NG s z LPG - -� 2- CDWS s 2- CDWR s 2- HWS s HWR -5 �- COND -5 MECHANICAL GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2009 IBC, 2009 WSEC, 2009 IMC. 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN INSTALLED. 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT, AND 10 FEET AWAY FROM, OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET. 11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING: - 0% TO 100% OF THE DESIGN SUPPLY AIR - CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. - INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED (OR GRAVITY DAMPERS PER EXCEPTIONS IN 1412.4.1) WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE. 13. THE CONTROL SYSTEM SHALL BE 7 -DAY PROGRAMMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK, AND CAPABLE OF A DEADBAND SETTING OF AT LEAST 5 DEGREES F (10'F FOR RESIDENTIAL BETWEEN THE HEATING AND COOLING SETPOINTS. AHU CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF RESETTING SUPPLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH SPECIFICATIONS AND APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISSIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE, SMACNA AND ASCE 7. ALL LIFE SAFETY HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip =1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO THE ABOVE NOTED CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE /SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM [INCL1UDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER THAN DEOTECTORSOSHALLHBETOFURNISHED AND INSTALLED BY ELECTRICALFCONTRACTOR MULTI-STORY NOTED OTHERWISE POWER- WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 22. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING SHALL OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING AND BOTTOM WALL CORNERS ( TRACKS SHOULD - TOP BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC) -ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). FLUNG WITH ROCK WOOL IS NOT ACCEPTABLE -ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING, ...) SHALL BE SEALED ON BOTH SIDES OF THE PENETRATION. - USE SECTION 905 OF THE 2009 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. - ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE. 23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 24. LOCATION AND DETAILS OF EQUIPMENT DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANc E WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 25. FOR RESIDENTIAL INSULATION ON DUCTWORK AND PIPING SEE ENERGY CODE CHAPTER 5 AND TABLES 5 -11 AND 5 -12. 26. ELECTRICAL SUBMETERING OF SYSTEMS AS REQUIRED BY SEATTLE ENERGY CODE CHAPTER 12 IS BY ELECTRICAL DUCT INSULATION (R- VALUE) N -R INSULATION R -VALUE LAST UPDATED: RESID. INSULATION R -VALUE 07 /21/10 REMARKS DUCT TYPE DUCT LOCATION SUPPLY, RETURN NOT WITHIN CONDITIONED SPACE: ON EXTERIOR OF BUILDING, ON ROOF, IN ATTIC, IN ENCLOSED CEILING SPACE, IN WALLS, IN GARAGE, IN CRAWL SPACES R -7 R -8 1,2,3 OUTSIDE AIR INTAKE WITHIN CONDITIONED SPACE VARIES R -8 1,2,4,5 SUPPLY, RETURN, OUTSIDE AIR INTAKE NOT WITHIN CONDITIONED SPACE: IN CONCRETE, IN GROUND R -5.3 R -5.0 1,2 SUPPLY WITH <55' OR >105' AIR TEMPERATURE WITHIN CONDITIONED SPACE R -3.3 NOT REQ. 1,2 t. REFER TO ENERGY CODE SECTION 1414.2 FOR FURTHER REQUIREMENTS 2. REQUIREMENTS APPLY TO HEATED AND MECHANICALLY COOLED DUCT SYSTEMS AS NOTED. INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.51 AND SEALED JOINTS. 3. WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS. 4. INSULATE OUTSIDE AIR DUCTS TO BUILDING ENVELOPE LEVEL PER ENERGY CODE CHAPTER 13 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R -7 FOR REST OF INSTALLATION ). 5. R -7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND LESS THAN 2,800 CFM. PIPE INSULATION (INCHES) LAST UPDATED: 01/17/07 SERVICE FLUID TEMP 'F INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (IN) CONDUCTIVITY RANGE MEAN TEMP RATING 'F RUN -OUTS UP TO 2 1 & LESS >1 TO 2 >2 TO 4 >4 TO 6 >6 HWS &R 141 -200 0.25 -0.29 125 0.5 1.5 1.5 1.5 1.5 1.5 HWS &R 105 -140 0.24 -0.28 100 0.5 1.0 1.0 1.0 1.5 1.5 CHWS &R 40 -45 0.23 -0.27 75 0.5 0.5 0.75 1.0 1.0 1.0 CHWS &R <40 0.23 -0.27 75 1.0 1.0 1.5 1.5 1.5 1.5 CDWS &R 40 -45 0.23 -0.27 75 0.5 0.5 0.75 1.0 1.5 1.0 CONDENSER WATER (FOR NON- ECONOMIZER SYSTEMS - INSULATION IS NOT REQUIRED DRAWING INDEX SHEET NO. SHEET TITLE M0.00 COVER PAGE M2.01 PARTIAL 1ST FLOOR PLAN - HVAC APN NUMBE LEGAL DESCRIPTION PORTION OF GOV LOT 15 IN SW 1/4 OF SECTION 10 -23 -04 AND THE NE 1/4 OF SE 1/4 OF SECTION 09 -23 -04 BEGIN NW CORNER OF SW 1/4 OF SECTION 10 -23 -04 TH S 01 -46 -02 W 107.22 FT TH S87 -33 -12 E 512.24 FT TH S 01 -46 -02 W 402.93 FT TH N 88 -13 -58 W 616.22 FT TH S 85 -07 -17 W 170.45 FT TO ELY MARGIN OF PRIMARY STATE HIGHWAY NO 1 SSR 99 PACIFIC HIGHWAY SOUTH TH N 86 -04 -33 W 5.00 FT TH N 03 -55 -27 E 120.50 FT TH N 37 -36 -51 E 90.14 FT TH N 03 -55 -27 E 150 FT TH N 86 -04 -33 W 10.00 FT TH N 03 -55 -27 E 61.90 FT TO BEGINNING OF 1266 FOOT RADIUS CURVE CONCAVE TO WEST TH N ALONG SAID CURVE 126.11 FT THRU C/A OF 05 -42 -27 TO A POINT ON SAID CURVE & A POINT ON E -W C/L OF SAID SECTION 9 TH S 89 -16 -45 E 224.58 FT TO E -W CORNER OF SAID SECTION 9 & POINT OF BEGINNING - LOT 2 OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L2000 -072 RECORDING NO 20001213900008 Hermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575 -9700 Fax: (206) 575 -9800 www.hermanson.com Contractor Reg #: HERMACL005BJ INTERNAP DATA CENTER SABEY UPS ROOM 3355 S. 120TH PLACE TUKWILA, WA 98168 Revisions t ±h St 51 ?5th St R7.1. C. 05/17/12 PERMIT SET No. Date By Description VICINITY MAP NO SCALE SEPARATE PERMIT REQUI RED FOR 0 Mechanical I Electrical 0 Pit mbing Gas Piping City of Tukwila BUILDING DIVISION SITE MAP NO SCALE M12l52 PERMIT SET Design Drawn Design Team DN BB Checked MG Scale AS NOTED Drawing Number C- 349 -00380 Project Number 14 -12 -00380 Issue Date 05/04/2012 COVER PAGE - HVAC a CITY OF TUKWILA OCT 0 it 2012 PERMIT CENTER M0.00 C.> UPS ROOM ECONOMIZER IN-LINE TRANSFER FAN SCHEDULE LAST UPDATED: 05/10/12 UNIT TAG LOCATION SERVES BASIS OF DESIGN (OR EQUAL) TYPE CFM ESP IN WG MOTOR ELECTRICAL LWA WEIGHT LBS REMARKS BHP HP V/PH TF-01 P-1 CEILING UPS ROOM ECONOMIZER COOLING COOK 300SQN-B 13,000 1.2 6.32 7.5 460/3 93 700 1-7 TF-02 P-1 CEILING UPS ROOM ECONOMIZER COOLING COOK 300SQN-B 13,000 L2 6.32 73 460/3 93 700 1-7 1 PROVIDE VFD RATED PREMIUM EFFICIENCY MOTOR 2 PROVIDE VARIABLE FREQUENCY DRIVE, ELECTRICAL DISCONNECT AND MOTOR STARTER (AS REQUIRED) - BY ELECTRICAL CONTRACTOR 3 PROVIDE REINFORCED FAN WHEEL AND 1"THICK INSULATED FAN HOUSING 4 PROVIDE HANGING SPRING ISOLATORS (4 TYP) 5 PROVIDE FAN MOTOR COVER AND OSHA GUARD 6 INSTALL PER MANUFACTURER RECOMMENDATIONS 7 FOR TRADE COORDINATION REFER TO APPROVED SUBMITTALS / ".. ( :IN, \ „. 26.4KV XFMR. #1 600A HV III X 2500KVA USS-1 SWITCH (FRONT) (FRONT) 2500KVA XFMR. #1 USS-2 26.4KV 600A HV X SWITCH (FRONT) SERVICE SWBD #1 38/26 2ZZZZ222 X X X X • UPS INPUT SWBD. BA I IERY-1 s UPS MOD-1 BA UPS MOD-3 TTERY-3 , \` FD'S FSD — J 1 J RA RA3 iEEEHEFEFFI UPS UTIL S.S. tip,s, rl UPS/AC-3 UPS MOD-2 BA I IERY-2 UPS/AC-4 UPS MOD-4 BP I IERY-4 DESIGN NOTES: 0 96X96 LOUVERED OSA ECONOMIZER OPENING PROTECTED WITH MOTORIZED FIRE SMOKE DAMPER. INSTALL 4" MERV—II FILTER IN GALVANIZED FILTER RACK DOWNSTREAM OF THE DAMPERS. S/FIRE DAMPER INTERLOCK WITH BUILDING CONTROLS — BY OTHERS. 40X30 TRANSFER FAN INTAKE OPENING. PROTECTED BY in MESH & MOTORIZED SMOKE FIRE DAMPER. SMOKE/ FIRE DAMPER INTERLOCK WITH BUILDING CONTROLS TO BE PROVIDED BY OTHERS. 0 NEW TRANSFER FAN DESIGNED TO PROVIDE COOLING WITH OUTSIDE AIR DURING OSA ECONOMIZER CONDITIONS. FAN PROVIDED WITH VFD CONTROLS, SEE SCHEDULE FOR ALL DETAILS. ECONOMIZER LOGIC, CONTROLS, AND CONTROLS INTEGRATION TO BE PROVIDED & INSTALLED BT CONTROLS CONTRACTOR. EXTEND EXISTING EXHAUST PLENUM TO ACCOMMODATE ADDITIONAL EXHAUST GRILLES. 48X36 TITUS 301RL SUPPLY GRILLE DIRECT AIR TOWARDS THE ROLL—UP DOORS (4 TYP). FIELD COORDINATE BEST LOCATION FOR VFD CONTROLS. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 3 0 2012 City of Tukwila BUILDING DIVISION -------- CONNECT 3/4" CW TO EXISTING CW MAIN. PROVIODE CODE REQUIRED BACKFLOW PREVENTION AREA OF WORK , „,,, ,, ,,, ., „,,,,,,,,,,,- 3 , 4: :rt.. ,, , r, ”: , , ,:,,,,,,,,, ' ..,i,,, " 1 ,, ., -' : : ;,,:e,17:::....,,,__7„1 ,,, :, : 1 ; ,„..,.:...::l „, KEY PLAN SCALE: NTS CAP :11111:1 ---------- RA 3-2 L_ FSD II C:) re) C:) C:) re) X FS 11 1 TF-1 3/4"CW INSULATE PER CODE 62/30 46/24 62/30 RA 3-4 FSD1 X • 46/24 1ST FLOOR PLAN - HVAC ySCALE: 1/8” = r.11 111!.7 54 I / of111 i I" ,, i. .../ 1 1 11 1 :11 1 I: 1 RECEIVED CITY OF TUKWILA OCT 0 4 2012 PERMIT CENTER PERMIT SET Hermanson Hermanson CompayLLP 1221 2nd Avenue Oh Kent, Washington 98N2 Tel: (206) 575-9700 Fax: (206) 575-9800 www.herrnansortcom Contractor Reg f:MDMACLOO5BJ —111111111■11111111IMMN INTERNAPDATA CENTER SABEY UPS ROOM 3355 S. 1201-1 PCE TUKWILA, WA TB Revisions 05/17/12 P1 IT SET No. Date By e1r1ption Design Design Terri DN Draw n Checked Scale BB MG AS NOTE Drawing Number C-34900380 Pro'ect Number 14— 1200380 Issue Date 05/ 4:40 1 2 PARTIAL 1S-TFLOOR PLAIN - HVAC M2.()1