Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M12-155 - HOME DEPOT
HOME DEPOT 6810 S 180 ST M12 -155 City *Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel 14o.: 3623049074 Address: 6810 S 180 ST TUKW Project Name: HOME DEPOT Permit Number: M12 -155 Issue Date: 10/29/2012 Permit Expires On: 04/27/2013 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: HD DEVELOPMENT OF MARYLAND PROPERTY TAX DEPT #4705 , PO BOX 105842 30339 MITCH HAYNAM 2100E WALNUT AV , FULLERTON CA 92831 MHAYNAM @AMSOFUSA. C OM Phone: 714 888 -6800 ANDERSON AIR CONDITIONING LP Phone: (714) 888 -6800 Address: 2100 EAST WALNUT AV , FULLERTON CA 92831 Contractor License No: ANDERAC901P9 Expiration Date: 10/29/2014 DESCRIPTION OF WORK: REMOVE (6) EXISTING ROOF TOP PACKAGE A/C UNITS, (8) UNIT HEATERS AND REPLACE WITH (6) SAME SIZE ROOFTOP PACKAGE UNITS. REPLACE (8) UNIT HEATERS SAME SIZE. REPLACE OLD EQUIPMENT WITH NEW. Value of Mechanical: $40,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie x with, Fees Collected: $673.56 International Mechanical Code Edition: 2009 Date: 10I 2C1,111- l ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pre e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: �— �0_,,, Date: \O-7-Q-0- Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. rinn• IMC -4/1O RA12-1 RS Printarl• 10-74 -7017 PERMIT CONDITIONS Permit No. M12 -155 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: Sprinkler coverage around unit heaters needs to comply with section 8.3.2.5 and figure 8.3.2.5 of NFPA 13 (2007 edition). 15: All new sprinlder systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 17: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. rinr. IM(: -4/1(1 M12 -155 Printpri• 1(1 -99 -2019 CITY OF TUKria Community Develop..: epartment Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 littp://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** Site Address: 6810 S 180th St. Tukwila, WA 98188 Tenant Name: Home Depot #PROPERTY +OWNER.:.:: .. j. .. `... '., Address: 2100 E Walnut Ave . Name: Home Depot Address: 2100 E Walnut Ave. Contr Reg No.: Exp Date: Anderac 901pq 10 -29 -12 Address: P. 0. Box 105573 City: State: Fullerton CA City: Atlanta Sake. 369 - 888 ' CONTACT PERSONS prson}receivling all p6,lect communlcation:'`y:.�. ii �, . "7,1"-'-': i •';' ' Ya'; Name: Mitch Haynam Address: 2100 E Walnut Ave . City: Fullerton State: CA Zip :92831 Address: 2100 E Walnut Ave. Contr Reg No.: Exp Date: Anderac 901pq 10 -29 -12 Tukwila Business License No.: Y)(4(7_, rA/i m 21 City: State: Fullerton CA Zip: 92831 Phone: Fax: 714 - 888 -6800 714 - 888 -2697 Email: Mhaynam @amsofusa.com King Co Assessor's Tax No.: 3623049074 -09 Suite Number: Floor: single New Tenant: ❑ Yes .. No .'MECHANICALCONTRACTOR .INFORMATION,' :.''. Company Name: Anderson Air Conditioning, LP Address: 2100 E Walnut Ave . City: Fullerton State: CA Zip :92831 Phone: Fax: 714 - 888 -6800 714 - 888 -2697 Contr Reg No.: Exp Date: Anderac 901pq 10 -29 -12 Tukwila Business License No.: Y)(4(7_, rA/i m 21 Valuation of project (contractor's bid price): $ 40,000 Describe the scope of work in detail: Remove (6) existing Roof top Package A/C Units , (8) Unit Heaters and replace with (6) same size rooftop package units. Replace (8) Unit Heaters same size. Replace old equipment with new equipment. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas Other: H:Wpplications\Forms- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 0, Indicate type of mechanical work being i ailed and the quantity below: Unit Type - - '' Qty Furnace <100k btu Furnace >100k btu 59 Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm _. , Type Unit ll , ..:::': Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial z : ',.z' "•c*:!' 7.;',,i'' • . UilitTypeL,..- ,:, ' '::-... :1,j c-tics= .t'-.!:-, •';'•:-., ',::::::, : — Qty.. ' '• + . ' ; Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment 1301ler/compressorc: : .: Qty ; 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNJR OR AUTHORIZED AGENT: Signature: Print Name: Mailing Address: 2-100 6- U.Z.,(ktAAJ— A, tie HAApplications \Forms-Applications On Linek2011 Applications \Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Day Telephone: Date: /0 City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3623049074 Address: 6810 S 180 ST TUKW Suite No: Applicant: HOME DEPOT RECEIPT Permit Number: M12 -155 Status: PENDING Applied Date: 10/04/2012 Issue Date: Receipt No.: R12 -02777 Initials: JEM User ID: 1165 Payment Amount: $673.56 Payment Date: 10/04/2012 01:49 PM Balance: $0.00 Payee: ANDERSON AIR CONDITIONING TRANSACTION LIST: Type Method Descriptio Amount Payment Check 30532297 673.56 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 538.85 000.345.830 134.71 Total: $673.56 doc: Receipt -06 Printed: 10 -04 -2012 _INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431 -2451 Project:, Type of Inspection: Address: (4 yt 0 ! "et, 9 __C7— Date Called: Special Instructions: F 73 fr_. / . Date Wanted:. rja.m: --/ 3 (p_m. Requester: lroncL Phone N4 . — 'IA 2 —r1 S/55 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Datej_� t1 ' I \ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit i "S PERMIT NO. CITY OF TUKWILA BUILDING DIVIS'FON 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: \ -k 0 w•F_ q I f Type of Inspection: ' Rain 1- ),..i Address: (c)l U ‘ i 9:0 Si- Date Called: - .i Special Instructions: Date Wanted: . 1 1 1 7/ 1 7 _ . p.m. Requester: Phone No: -7 I y--X12.0 --7-5-4. U Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: `` 0 l R41K/v4 -Fi`i' j- .- .AI /P'1 1-2 ALcr - 1 J ' 4/Afeel �41AS ke° Jh�/ c ha - .i t _ /'may w ey I spectbr Gttire•. Date: j / ///7 //Z._ IR INSPECTION FEE REQUIRE . Prior to next inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /412 - 15S- - PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: i jar►.,c rj,toc„ .; Type of Inspection: IAeche'r-vc6,e, / l-.:,G./ Address: 6s v a Suite #: S / creaky s1 Contact Person:: Special Instructions: Monitor:— Phone No.: . Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4/ SQ' e 1 k Jy ,-.. Ja A ease i s ,04 -m <Ues 4-0 he bki , Needs Shift_Inspection: " --- Sprinklers: Fire Alarm: - Hood` &Duct: Monitor:— `Pre -Fire: Permits: L '"occupancy Type :. Inspector: ' mP) Date: / z Jj 3 Hrs.: lig$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip.: uVord /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 httpsy/mapsgoogie.com /maps ?nl =en +Garret Sea images btaps Play Yor3Tulae Maims Gmail Documents Calendar More Got *le Seattle Airport, Seattle, WA FILE COPY R�Ct�vE� CITY OF TUKW$LA OCT 042012 PERMIT CENTER 1kA\T lc% FILE COPY Lennox Industries Inc. - Product Submittal System ID: UNIT HEATERS Furnace Model: LF24 -175A Description: UNIT HEATER HEATING PERFORMANCE Heat Source H/E HighInput H/E HighOutput Unit Heater 172500 (Btuh) 138000 (Btuh) Gas Supply Connection AFUE/ ThermalEff 0.50 (in.) 80 SUPPLY FAN PERFORMANCE Supply Fan Type CAV Direct Drive ELECTRICAL Voltage 115V 1Ph Cond Oper Range -Nom Voltage +/- 10% DIMENSIONS Furnace Weight Furnace Height Furnace Width Furnace Length 145 (lb) 32.2 (in.) 23.1 (in.) 31.3 (in.) Project: 3000290262 THE HOME DEPOT # 4705 Quote: 4000344897 THE HOME DEPOT # 4705 Page 18 of 21 REVIEWED FOR CODE COMPLIANCE APPROVE[ OCT 2 F 2012 • City of Tukwr`Ia BUILDING DIVISION Last Changed: DEREK GAREN Prepared On: 2012 -08 -24 Phone: 972 -497 -6082 RECEIVED CITY OF TUKWILA OCT 042012 PERMIT CENTER x/112155 Lennox Industries Inc. - Product Submittal System ID: UNIT HEATERS Furnace Model: LF24 -175A Description: UNIT HEATER INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 16L29 8 LF24 -150 /200 -DN -60 DISCHARGE NOZZLE Project: 3000290262 THE HOME DEPOT # 4705 Quote: 4000344897 THE HOME DEPOT # 4705 Page 19of21 Last Changed: DEREK GAREN Prepared On: 2012 -08 -24 Phone: 972-497-6082 Lennox Industries Inc. - Product Submittal System ID: UNIT HEATERS Furnace Model: LF24 -175A Description: UNIT HEATER DIMENSIONS - INCHES (MM) NOTE • Single fan model shown, LF24 -100. 115. 145.175 and -200. LF24.230.250. 300.345 and -400 models have two fans. 1 NOTE -Two rivetnuts are furnished on LF24. 100•115 •145,•175 and •200 models. - Four rivetnuts are furnished on LF24. 230. 250300.345 and -400 models. 7 •5/8 (194) 3/8 -16 RIVETNUTS FOR UNIT SUSPENSION I Furnished on LF24-345 and LF24 -230, LF24 -250,' LF24.300, Mil Modals Only. °I ADJUSTABLE LOUVERS 32 -3/16 (817) FRONT VIEW 1/2 (13) TOP VIEW FLUE OUTLET ELECTRICAL INLETS COMBUSTION AIR INDUCER DIRECT DRIVE FAN SIDE VIEW GAS VALVE Model No. in. A mm B in. mm C in. mm D in. mm E in. mm F in. mm LF24 -100 LF24 -115 LF24-145 20 -3/16 512 11 -1/2 292 19 -1/16 484 11 -3/4 298 3 -1/4 83 7 -7/8 200 LF24175 LF24200 23 -1/8 588 11 -1/2 292 22 -1/16 560 8 -1/2 337 3 -1/4 83 8 -11/16 220 LF24 -230 LF24 -250 LF24 -300 41 -1/8 1045 3 -11/16 97 40 1016 17 -3/4 451 3 -1/2 89 8 -11/16 220 LF24345 LF24400 41 -1/8 1045 3 -11/16 97 40 1016 17 -1/2 445 3 -1/2 89 9 -13/16 248 Project: 3000290262 THE HOME DEPOT # 4705 Quote: 4000344897 THE HOME DEPOT # 4705 Page 20 of 21 Last Changed: DEREK GAREN Prepared On: 2012 -08 -24 Phone: 972 - 497 -6082 -r r =f 1 I • s'kr__t,�a ,r _ �,l�o - I >L 2vQ•! 141—K1 K3 i I t a t -t 1- -i i I - -1 -t , i 1- t IDcJ ' WAS:ti�,✓S jW _. 1 1 1 - -- 1 - - -_ - -. 1 i I [Reznor Online] Product Catalog Ez_ �v^ Contact Us I Advanced Search I Site Map Reznor Catalog Unit Heater B F LDAP OH UDAP UDAS UDBP UDBS UEAS Air Tumover Blower Cabinets Condensing Units Direct Fired Electric Heaters Energy Recovery Evaporative Cooling Gas Infrared Heating/Cooling Makeup Air Hydronic IA() Ventilators Indoor Duct Furnace Indoor Packaged MISC Obsolete Products Outdoor Duct Fumace Outdoor Packaged Used -Oil -Fired Heaters Reznor Europe Reznor China Reznor UK Page 1 of 3 HVAC Solutions lndustna! • Commercial • Residential Search Search rHome E Products I Support / Specify Manuals & Media Reznor Catalog r, Rebate Information It is currently: 11:23 am (CST) on 08/02/2012 • Click on a Category to view the Reznor Models. • Links below will move you back & forward NOTE: Weights listed are net weights for base unit only, options can change unit weights significantly. For option weights, please consult the printed catalog or your Reznor Representative. Catalog» Unit Heater Model List» Model F Model Detail Standard Features Optional Features Performance Info Dimension Into literature Reznort7 series 100, model F gas - fired, gravity - vented unit heaters are designed for 80% thermal efficiency and are designed for use with natural or propane gas, as specified, in sizes from 25,000 to 400,000 BTUH gas input. Model F unit heaters are designed for ceiling suspension with a propeller fan for air delivery. Standard features include a manual match -lit pilot with 100% shutoff and a single- stage, 24 -volt gas valve. A terminal strip connector facilitates field connection to a remote 24 -volt thermostat for automatic operation. Each unit is provided with a fan control and all required limit safety controls, including an energy cutoff (ECO) device and a blocked vent switch. These units are approved for installation in the United States and Canada by the Canadian Standards Association(CSA). WARNING: Gas -fired appliances are not designed for use in hazardous atmospheres containing flammable vapors or combustible dust, or atmospheres containing chlorinated or halogenated hydrocarbons. Installations in public garages or airplane hangars are permitted when in accordance with ANSI Z223.1 and NFPA 54 codes or CAN1 -B149 codes and enforcing authorities. Notes: • Model F units for California require the addition of spark pilot option AH2 or AH3. • Not certified for residential use. Eli • Orifices for natural gas • Aluminized steel heat exchanger • Aluminized steel bumer rack with stainless steel insert • Manual match -lit pilot with 100% shutoff • Single -stage combination gas valve (field adjustable for high altitude operation) • 115/1/60 supply voltage • 115 volt fan motor with intemal overload protection • Fan and limit safety controls • Energy cutoff (ECO) device • Blocked vent shutoff system • 24 -volt control voltage transformer • Individually adjustable horizontal louvers • Full safety fan guard • Terminal strip connector for 24 -volt field wiring • Convenient bottom bumer access • 2 -point 3/8" -16 threaded hanger connections • Horizontal/vertical vent outlet Optional Features - Factory Installed: • Equipped for propane gas • Equipped for high attitude (2001 -9000 ft) • E-3 (409) stainless steel heat exchanger and burner • Two -stage gas control (50% low fire) - sizes 75-400 • Spark ignited, intermittent safety pilot with electronic flame supervision with or without timed lockout (timed lockout is required for propane gas) • Manual summer/winter switch • Burner air shutters • 220/240 vott/50 Hertz electrical operation • Totally enclosed 115V motor • Low ambient fan control relay Optional Features - Field Installed: • Power venter • Vertical louvers https://www.rerspec.com/catalog-fhtml 8/2/2012 [Reznor Online] Product Catalog Page 2 of 3 • Downtum air nozzle, 25-650 or 50 -90o vanabte air deflector range (includes 4 -point suspension kit) • Thermostat and relay kits • Air recirculation kits • Manual summer/winter switch • Multiple heater control • 4 -point suspension kit • Unit - mounted thermostat bracket • Step down transformer 230/115 or 460/115 • Burner air shutters • Low ambient fan control relay kit • Hanger kit to suspend from 1, pipe (2 or 4 point suspension) • Single -stage and two -stage thermostats • Thermostat guard with locking cover • Manual shutoff valve and union • Gas conversion kit Size Efficiency Input MBH Output MBH Number of Blower/Fan Minimum Maximum Blowers /Fans Size (In.) CFM CFM 25 80% 25 20 1 ' 10" 380 380 50 80% 50 40 1 10" 650 650 75 80% 75 60 1 12" 980 980 100 80% 100 80 1 14" 1250 1250 125 80% 125 100 1 16" 1600 1600 —4 165 80% 165 132 1 16" 2200 2200 200 80% 200 160 1 20" 2800 2800 250 80% 250 200 1 22" 3360 3360 300 80% 300 240 1 22" 3800 3800 400 80% 400 320 1 24" 4940 4940 Size: Weight (lb.) Length (In.) Width (In.) Height (In.) Vent Dia 25 72 27 13-1/2 30-1/8 4" Rd 50 79 27 13-1/2 30-1/8 4" Rd 75 88 27 15-1/2 30-1/8 5" Ov 100 97 30-1/2 17-1/2 30-1/8 6" Ov 125 127 30-12 23-3/4 32 7" Ov ---- 165 149 35-1/2 20-1/4 40 -1/8 8" Ov 200 170 36-1/4 23-1/4 40-1/8 8" Ov 250 204 36-1/4 28 -3/4 43-1/2 10" Ov 300 221 36-3/4 28-3/4 43-12 10" Ov 400 276 37 -1/4 37 43-12 12" Ov Product Literature ( Adobe Acrobat Files In ) Product Submittals >Unit Heaters - Models UEAS /UDAP /UDAS/UDBP/UDBS /F /B /OH /LDAP Air -Throw Floor- Coveraoe.pdf Air throw and Floor coverage for Models UDAP, UDAS, UDBP, UDBS, F & B Full Load Amp Table,pd( Full Load Amp Tables for Reznor Unit Heaters F TechData.pdf Description, options, dimensions and technical data for Model F OptionsAccessones.pdf Descriptions of various options and accessories Sample- Soecifications.pd( Sample specifications for Models UEAS, UDAS, UDAP, (JOBS, UDBP, F, B, OH & LDAP Warranty pd( Warranty information on all Unit Heaters Catalogs C-UH.odf Unit Heater Catalog Installation Manuals I -F B.odf Installation manual for Models F 8 B (applies to units with electronic, spark ignition pilots). Installation Manuals >Recently Discontinued Models I -F B pdf Installation manual for Models F & B for unit with standing pilot (Applies to units built before Sept. 2007) Marketing Catalogs MC- UH.odf Benefits, features and applications of Reznor Unit Heaters - Models UEAS, UDAP, UDAS, UDBP, UDBS, LDAP, OH, EXUB, EGEB, and WS Parts Manuals P- FAN- LIMIT,od( Replacement Fan & Limit Controls P -F B.pdf Replacement Parts - Model Series: B, BE, F, FE Unit Heaters P- PILOTS.pdf Replacement Pilots & Ignitors P- VALVES.pdf Replacement Valves, Ignition Controllers, Maxitrol Components & Serial Number Lookups Terms of Use - Privacy Policy - Thomas & Betts Corporate Website https: / /www.rerspec.com/catalog- f.html 8/2/2012 [,Reznor Online] Product Catalog Page 3 of 3 Thomaselleits 02007 Thomas 8 Betts Corporation. All Rights Reserved. Toll Free: (800) 895-1901 Email: Contact Us https: / /www.rerspec.com/catalog -fhtml 8/2/2012 FILE COPY Advance Product Data 48HJD /HJE /HJF Single- Package Rooftop Units Electric Cooling /Gas Heating 3 to 10 Nominal Tons Weathermaster, SERIESI REVIEWED FOR CODE COMPLIANCE APPROVED Copyright 1992 Carrier Corporation The Weathermaster Series... Masters by Design Carrier, the number one manufacturer of packaged rooftop units, has de- signed its new "Weathermaster" Series to meet its customers' grow- ing needs of today and tomorrow. Based on customer requests, the new Weathermaster Series has been designed to provide excellent year - round operating efficiencies, as well as unprecedented ease of mainte- nance and installation, and the high- est reliability in the industry. Standard Features • belt- driven evaporator -fan motors on all sizes • low sound levels down to 8.0 bels • SEERs (Seasonal Energy- Efficiency Ratios) up to 12.0 • UL, ARI, CSA certified and approved • EERs (Energy Efficiency Ratios) up to 100 • 2 -in. disposable return -air filters requiring no tools for removal • 10 year warranty on heat exchangers • 5 year compressor warranty • high and low pressure (loss -of- charge) and freeze protection switches • heating AFUEs (Annual Fuel Utilization Efficiency) and steady state efficiencies up to 82% • 24 -v controls with resettable circuit breaker • non - chalking exterior cabinet with non - corrosive exterior screws • permanently lubricated evaporator - fan motors • totally enclosed, permanently lubri- cated condenser -fan motors • full perimeter base rails with built-in rigging capability • easy field conversion from vertical to horizontal supply /return • DrainGuardm corrosion - resistant con- densate pan with internal trap con- forms with ASHRAE Standard 62 self - draining requirement AA12 -ISS Form 48HJ-IAPD KO- J Table of contents Page Standard Features 1, 2 Model Number Nomenclature . .3 ARl Capacities 4 Physical Data .5, 6 Options and Accessories ....•. .... 7, 8 Base Unit Dimensions 9,10 Accessory Dimensions .11, 12 Selection Procedure 13 Performance Data . 14 -23 Electrical Data 24 Typical Piping and Wiring . ..25 Application Data .26 Controls . 27 Typical Control Wiring Schematic . 28, 29 Guide Specifications . . 30 -35 Model number nomenclature 48 — Gas Heat HJ— Constant Volume D — Low Heat E — Medium/High Heat F — High Heat 48 HJ T Nominal Capacity 004 — 3 Tons 008 — 7 1/2 Tons 005 — 4 Tons 009 — 81 /2 Tons 006 — 5 Tons 012 — 10 Tons 007 — 6 Tons 004 - - AA FLOP Code' 1 — 575 -3-60 3 — 208/230.1 -60t 5 — 208/230-3-60 6 — 460 -3-60 `Refer to 48HJ price pages for FIOP (Factory - Installed Options) code table. t5 -ton unit motor is 230-1-60 only • 3 Physical data BASE UNIT 48 HJE /HJF004 HJD /HJE005 1 il' HJIY/''JE008 . i Ji HJD /HJE007 NOMINAL CAPACITY (tons) 3 4 11 5 i g 6 OPERATING WEIGHT (lb) Unit With Economizer Roof Curb 530 564 115 540 574 115 560 a I 594 115 % 615 649 115 COMPRESSOR Quantity O11(02) Reciprocating 1 45 Sbii 1 60 I i 1 ( 75 Reciprocating 1 65 REFRIGERANT TYPE Operating Charge (lb-oz) Ft T22 5 -2 7 -11 th 8 -4 81F. 9 -12 CONDENSER FAN Quantity...Diameter(in.) Nominal Cfm Motor Hp...Rpm 1.. 26 4600 113. 850 Propeller 1.. 26 4100 1/3 ..850 1...28 i 4100 1/3. 850 1 28 ( 4100 1/3 .850 CONDENSER COIL Rows...Fins /In. Total Face Area (sq ft) 1.17 12 25 Enhanced Copper Tubes, 2 17 k�4 12 25 I r Aluminum Lanced Fin 2.. 17 1 2...17 I 12.25 I_ ;S 12 25 EVAPORATOR FAN Size(in.) Type Drive Std Alt Nominal Cfm Maximum Continuous Bhp Std Alt Motor Frame Std Alt Nominal Rpm High /Low Std Alt Fan Rpm Range Std Alt Motor Bearing Type Maximum Fan Rpm Motor Pulley Pitch Diameter A/B (in.) Std Alt Fan Pulley Pitch Diameter (In.) Std Alt Belt — Type...Length(in.) Std Alt Pulley Center Line Distance (in.) Std Alt Speed Change per Full Turn of Std Movable Pulley Flange (rpm) Alt Movable Pulley Maximum Full Turns Std from Closed Position Alt Factory Setting — Full Turns Open Std Alt Factory Speed Setting (rpm) Std Alt Fan Shaft Diameter at Pulley (in.) 10x10 Belt Direct 1200 t 34 t 48 t 860/845 t Ball 2100 t — t — t t — t — t — t — t — t Centrifugal 10x10 Belt Direct 1600 1 30 .81 56 48 — 1080/970 800 -1100 Ball 2100 2 4/3 4 — 5 2 — A 40 14 7_15 5 66 — 5 — 3 — 930 — 5/8 10x10 Belt Belt 2000 1 70 56 ' — — 920-1300 M 5 Bali " 0 2100 2 4/3 4 — 4 5 X14, — A 40 14 7_15 5 � = 76 1; 5 .•' . — 3 — i ` %+ 1075 — r' " 5/e 10x10 I Belt " ci 2400 ( 240 E! 56 i — r — ,' 1070 -1460 Ball 2100 2 8/3.8 — 4 5 — A 39 ; 14 7-15.5 I 79 — 5 — 1 3 — 1230 5/3 EVAPORATOR COIL Rows...Fins/in. Total Face Area (sq ft) Enhanced Copper 2. .15 4 17 Tubes, Aluminum Double 2.. 15 5 5 Wavy Fins, AcutroiF" 3 . 15 5 5 Feed Device 4.. 15 i, 5.5 FURNACE SECTION Burn Orifice Diameter (In....drill size)* Natural Gas — Std Liquid Propane — Alt Thermostat Heat Anticipator Setting (amps) 208/230/480/575 v Gas Input Efficiency (Steady State) (%) Temperature Rise Range Manifold Pressure (in. wg) Natural Gas — Std LiquidPropane —Alt Field Gas Connection Size (in.) .113 ..33 .089 ..43 1.0 74,000/115,000 81 25- 55/55 -85 3.5 3.5 5 113. 33 .089 .43 1.0 74,000/115,000 81 25- 55/35 -65 3 5 35 5 ; <. 4 ' a _ ? u �', ' .! 113 33 089. 43 1 0 w' 74,000/115,000 81 25- 55/35 -65 3.5 3.5 I 5 113 33 089 ..43 i 1 0 s 74,000/115,000 81 25- 55/35 -65 3.5 3.5 5 HIGH - PRESSURE SWITCH (psig) Cutout Reset (Auto.) 428 320 LOSS-OF-CHARGE/LOW-PRESSURE SWITCH (Liquid Line) (psig) Cutout Reset (Auto.) 7 ± 3 22 ± 5 OUTDOOR -AIR INLET SCREENS Quantity...Size (In.) Cleanable 1 . 20 x 24 x 1 RETURN -AIR FILTERS Quantity...Size (In.) Disposable 2 16 x 25 x 2 LEGEND Bhp — Brake Horsepower "48HJD005-007 and 48HJE004 (74,000 Btuh) units have 2 burners 48HJE005 -007 (115,000 Btuh) units have 3 burners 1-Data is not currently available 5 Options and accessories ITEM OPTION* ACCESSORYt Economizer X X Manual Outdoor -Air Damper x Two - Position Damper X X Alternate Motor and Drive (004,005,008 -012) X Roof Curb X Thru- the -Curb Service Connections X Flue Shield X Thermostat and Subbase X Electronic Programmable Thermostat X Time Guard® 11 Control Circuit (3 phase units only) X Motormaster® Head Pressure Control (004-007) X Motormaster® II Head Pressure Control (004 -012) X Accusensor" II Enthalpy Control X Accusensor' 111 Differential Enthalpy Control X LP Conversion Kit x Hall Guard X Remote Control Panel X NO Reduction Kit X Flue Discharge Deflector X 'Factory installed tField installed HEAD PRESSURE CONTROL The 48HJ004 -012 standard units are designed to operate In cool- ing at outdoor temperatures down to 25 F With accessory Mo- tormaster control (condenser fan speed modulation for unit sizes 004 -007) or Motormaster II control (condenser fan cycling for unit sizes 004 -012), units can operate at outdoor temperatures down to —20 F The head pressure controls, which mount in the con- denser section, control the condenser fan motor to maintain cor- rect condensing temperature MOTORMASTER (Sizes 004-007) MOTORMASTER II (Sizes 004 -012) LP CONVERSION KIT BURNER SPUDS (ORIFICES) LP conversion kit allows the unit to utilize a liquid propane fuel supply in areas where natural gas is unavailable. (Kit shown is for sizes 004 -007.) Time Guard II Control automatically prevents compressor from restarting for at least 5 min- utes after a shutdown Accessory prevents short cycling of compressor if thermostat is rapidly changed Time Guard II mounts in the control compartment of unit. TIME GUARD II CONTROL 74 SUMO iC • 0 01 .�. .w+.x 1004 6,4004 SWUM l •rte . U la .. aa.r Ma. 7 Base unit dimensions — 48HJ004 -007 1' -5 S16' (4401 0' -7 1/4" (1841 -10 13/1.' (2751 0' -4 1/16' (1031 FILTER ACCESS PANEL (DISPOSABLE F ILTERS) 2' -1 11/16" (6537 0,11718' 1302) 0' -5 3/4' (146) 2' -1 15/16" (659] OUT IDE OF PANEL SUPPLY AIR NOTES: 1 Dimensions in ) ) are in millimeters 2 Center of Gravity 3 Direction of airflow RETURN AIR E STD CONDENSATE DRAIN (IN1ERNALLY RIGHT S IDE TITAPPED) ACCESSORY HOOD FILTER 1' -1 1/4" OUTDOOR AIR 0C2gg )6178 0' -5 11/16" fl 443 4 On vertical discharge units, ductwork 10 be attached to accessory roof curb only For horizontal discharge units, field - supplied flanges should be attached to horizontal dis- charge openings and all ductwork should be attached to the flanges 5 Minimum clearance (local codes or jurisdic- tion may prevail): e Between unit, flue side and combustible sur laces, 38 Inches b Bottom to combustible surfaces (when not using curb), one in on HJF units, zero in on all others c Condenser coil, for proper airflow, 38 In one side, 12 in the other The side getting the greater clearance Is optional d Overhead, 60 in, to assure proper con- denser fan operation e Horizontal supply and return end, zero Inches 1 Between units, control box side, 421n per NEC (National Electrical Code). g Between unit and ungrounded surfaces, control box side, 38 In per NEC h Between unit and block or concrete walls and other grounded surfaces, control box side, 42 in per NEC 6 With the exception of the clearance for the condenser coil and combustion side, as slated in notes 5a, b, and c, a removable fence or barricade requires no clearance 7 Units may be installed on combustible floors made from wood or class A, B, or C roof cov- ering material ELECTRICAL DISCONNECT LOCATION CORNER UNIT CONNECTION SIZES A 13/e" Dia (35) Field Power Supply Hole 8 2° Dia (51) Power Supply Knockout C 131." Dia (44) Charging -Port Hole 0 '/s" Dia (22) Field Control Wiring Hole E 314" -14 NPT Condensate Drain F +/z• -14 NPT Gas Connection G 21h" Dia (64) Power Supply Knockout ELECTRICAL DISCONNECT LOCATION CORNER UNIT STD UNIT WEIGHT ECONOMIZER WEIGHT CORNER WEIGHT (A) CORNER WEIGHT (8) Lb Kg Lb Kg Lb Kg Lb Kg 48HJE /HJF004 530 240 34 15 4 104 47 2 97 44 0 48HJD /HJE005 540 245 34 15 4 106 48 1 98 44 5 48HJD /HJE006 560 254 34 15 4 110 49 9 102 46 3 48HJ0/HJE007 615 279 34 15 4 120 54 4 112 50 8 • 3'415116' 11091) FILTER /ECONOMIZER ACCESS PANEL CONDENSER COIL yam] OUTDOOR AIR 2' -0 15/15" 0' -4 1/2' (633) (114) OPTIONAL ECONOMIZER HOOD 1' -4 3/8' (416) I_ .-CORNER "8" "'0' -3 3/16' 1811 0' -10 15/16' C2781 3 -9" (1144) 1'-5' (432) 0' -2 15/16'-"' f 75 0' -4 9/8 "- (118) ALT. CONDENSATE )RAIN OPENING 1N BASEPAN 1 SUPPLY-AIRI OPENING VERTICAL CORNER "0" 1' -2 1/4" a0' -3 13/16" 197] B FLUE HOOD 2' -9 5/16" (8471 1' -4 5/16" (4151 3' 5 3/16' 0 - -2 9 16" (1046) (65) LEFT SIDE 0' -6 5/8' (1681 0' -3 1 /16' 6' -) 11/ (1872] 2' -11 1/2' _1 (9021 4:70 1/1 FRONT RETURN AIR /4W4 -5 3/8' (137] `0' -2 9/16" (65) 1' -5 3/4" (451) I SUPPLY AIR %/ /// 0' -S 7/16" (138) 00' -3 3/16 R 'C' °- (8)) 1'-6 118" CORNER WEIGHT CORNER WEIGHT UNIT (C) (D) COMPRESSOR/ I Lb Kg Lb Kg 48HJE /HJF004 159 72 1 171 77 6 48HJ0/HJE006 162 73 5 174 78 9 48HJD/HJE008 168 76 2 180 81 6 48HJD /HJE007 185 83 9 198 89 8 • 3'415116' 11091) FILTER /ECONOMIZER ACCESS PANEL CONDENSER COIL yam] OUTDOOR AIR 2' -0 15/15" 0' -4 1/2' (633) (114) OPTIONAL ECONOMIZER HOOD 1' -4 3/8' (416) I_ .-CORNER "8" "'0' -3 3/16' 1811 0' -10 15/16' C2781 3 -9" (1144) 1'-5' (432) 0' -2 15/16'-"' f 75 0' -4 9/8 "- (118) ALT. CONDENSATE )RAIN OPENING 1N BASEPAN 1 SUPPLY-AIRI OPENING VERTICAL CORNER "0" 1' -2 1/4" a0' -3 13/16" 197] B FLUE HOOD 2' -9 5/16" (8471 1' -4 5/16" (4151 3' 5 3/16' 0 - -2 9 16" (1046) (65) LEFT SIDE 0' -6 5/8' (1681 0' -3 1 /16' 6' -) 11/ (1872] 2' -11 1/2' _1 (9021 4:70 1/1 FRONT RETURN AIR /4W4 -5 3/8' (137] `0' -2 9/16" (65) 1' -5 3/4" (451) I SUPPLY AIR %/ /// 0' -S 7/16" (138) 00' -3 3/16 R 'C' °- (8)) 1'-6 118" CONTROL BOX/ [460) COMPRESSOR/ I EVAPORATOR -FAN MOTOR & BURNER ACCESS PANEL BLOWER ACCESS PANEL 0' -4 3/16 "J (106] _} F .4010 =1 Q01 2' 5 3/8" (746] 0' -8 7/16" (214] FRONT RKUFT SLOTS 0' -2 1/7 -01A (TYP 8 PLACES) 0' -0 3/8" (101 9 • • Accessory dimensions 0 -3" (76) 1 (761 1 1' -1 7/16- 1341) 0' -0 7/16' 1I)) (BOLT NEARS) N., 1 �X C or-ti �-.it ( ./l 4 SUPPLY -018 OPENING RETURN -A) OPENING C5O4) 0' (76-33 ' o -o 7/15 y 3' -O' A (11) 1914) (BOLT HEADS) 111/6 03341 ROOF CURB — 48HJ004 -007 ROOF CURB ACCESORY 60DJ900771 "A„ UNIT SIZE 1' -2" [3561 50DJ900781 2' -0" [610) 48HJE /HJF004, 48HJD /HJE006 -007 NOTES: 1 Roof curb accessory Is shipped unassembled 2 Insulated panels 3 Dimensions In ( ) are In millimeters 4 Roof curb: galvanized steel 5 Attach ductwork to curb (Flanges of duct rest on curb ) 6 Service clearance 4 ft on each side 7 % /// Direction of airflow UNIT SIZE "B" "C" D ALT DRAIN HOLE GAS "F" POWER "0" CONTROL CONNECTOR PKG. ACC. 48HJElHJF004, 48HJD /HJE005 -007 1-91 1/1 [551) 1-4" (406) 1-3/4" (45) 3/4" (19) NPT +/4" (19) NPT 3/4" (191 NPT 500.1900791 5/8" (803) 0' -0 7/16' 11 I) (BOLT HEADS) 0' -0 1) )) 7/16' (BOLT NEAOS) 4 A GASKET (SUPPLIED WITH CURB) UNIT NAIL TYPICAL (4) SIDES (FIELD SWPLI ED) COUNTER FLASHING (FIELD SUPPLIED) ROOFING FELT (FIELD SUPPLIED) CANT STRIP (FIELD SUPPLIED) ROOFING MATERIAL (FIELD SUPPLIED) 1 5/32' 1303 SECTION "C-C' SCALE 1,4 SEE NOTE 2 RIGID INSULATION (FIELD SUPPLIED) -E' GAS SERV I CE PLATE 1' -4 13/16' (427) (INSIDE/ OVER SERVICE -0- PLATE CONTROL 0' -7 ,,,6. SERVICE (179) PLATE (INSIDE) HEAD OF DOLT TO BE ON INSIDE OF FLANGE 5' -7 1/6" 3' -0 15/16' 1938) SEE VIEW (1705) 11 Selection procedure (with 48HJ005 example) I Determine cooling and heating requirements at design conditions. Given: Required Cooling Capacity (TC) ... 46,000 Btuh Sensible Heat Capacity (SHC) 32,000 Btuh Required Heating Capacity 85,000 Btuh Condenser Entering Air Temperature .... . 95 F Evaporator Enter Air Temperature 80 F edb, 67 F ewb Evaporator Air Quantity 1600 cfm External Static Pressure (ESP) ... . .75 in. wg Electrical Characteristics (V- Ph -Hz) .. 230 -1 -60 II Select unit based on required cooling capacity. Enter the Cooling Capacities table (page 14) at condenser entering temperature of 95 F, evaporator air entering at 1600 cfm and 80 F db and 67 F wb. The 481 -1J005 unit will provide a total cooling capacity of 49,500 Btuh and a sensible heat capacity of 35,700 Btuh. For evaporator -air temperature other than 80 F edb, calculate sensible heat capacity correction, as required, using the formula found in the notes following the Cooling Capacities tables. NOTE: Unit ratings are gross capacities and do not in- clude the effect of evaporator -fan motor heat. To calculate net capacities, see Step V. III Select heating capacity of unit to provide de- sign condition requirements. In the Heating Capacities and Efficiencies table (page 4) note that unit 48HJE005 will provide output capacity of 93,150 Btuh, which is adequate for the given application. IV Determine fan speed and power requirements at design conditions. Before entering the Fan Performance tables, calculate the total static pressure required based on unit components. From the given and the Pressure Drop tables (page 22), find: External static pressure .75 in. wg Economizer .05 in. wg Total static pressure = .80 in. wg • Enter the Fan Performance table for 48HJ005 vertical discharge units. At 1600 cfm, the standard motor will de- liver .80 in. wg static pressure and .93 bhp This will ade- quately handle the job requirements. To determine the input power to the motor, convert bhp to Watts using the Evaporator -Fan Motor Efficiency table (page 22). For example: Bhp x 746 Watts 1FM Watts — Bhp Motor Efficiency .93x746 .81 IFM Watts = 866 V Determine net cooling capacity. Cooling capacities are gross capacities and do not include indoor -fan motor (IFM) heat Determine net capacity using the following formula: Net capacity = gross capacity - FM heat = 49,500 Btuh - 866 Watts (3.413 Btuh a ) Watts = 49,500 Btuh - 2956 Btuh Net capacity = 46,544 Btuh Net sensible capacity = 35,700 Btuh - 2956 Btuh Net sensible capacity = 32,744 Btuh 13 • • COOLING CAPACITIES (cont) 48HJ008 (71/2 TONS) Temp (F) Air Ent Condenser (Edb) Temp (F) Air Entering Evaporator - Cfm /BF 2250/0.075 3000/0.105 3750/0.125 Temp (F) Air Enter ng Evaporator - Ewb (F) 72 67 82 72 67 82 72 87 62 TC 106 4 97 5 89 1 111.0 102.0 93 8 113.6 105 0 96.7 85 SHC 51.1 63.1 74.8 55.7 71.5 86.3 60.0 79.6 95.3 kW 6 52 6 39 6.26 8 60 8 46 635 6 65 6.52 6 42 TC 102.7 94 4 85 5 106 8 :;911:8•.. 90 2 109.4 101 4 93 4 95 SHC 49.7 81 8 73.3 54.2 :170:8', 84 7 58,7 78.4 93.0 kW 730 718 705 738 127 715 7.43 732 720 TC 98 6 90 7 81 1 102.6 94 7 85 8 105.0 96 8 89.8 105 SHC 48 2 60.5 71.2 52.8 89 0 82.3 57.3 76 5 89.7 kW 8 15 8 04 7 89 823 8 13 7 97 829 8 17 8.06 TC 94.4 86.5 76 2 98 2 89 9 81 7 99 4 921 86 4 115 SHC 46.6 58.7 68.9 51 2 86.9 80.0 55 3 74.5 88.2 kW 9 06 8.95 8.79 9 16 9 01 8 88 9 17 9 06 8 99 48HJ012 ( 0 TONS) AIr En) Condenser (Edb) Temp (F) AIr Entering Evaporator - Cfm /BF 3000/0.055 I 4000/0.08 5000/0.10 Temp (F) AIr Enter ng Evaporator - Ewb (F) 72 67 62 72 87 82 72 67 82 TC 138.8 128.2 1149 1429 1327 121 9 1464 138.8 1274 85 SHC 68.2 84.9 100.0 75.1 97.1 115 9 81.4 108.2 126 9 kW 826 810 7.93 837 822 806 845 830 816 TC 132.9 121 8 109.1 138.3 127.8:: 116 1 141.5 131 6 122 9 95 SHC 67.0 83.1 97.3 73.8 :;X4'. 112.9 80.2 106 5 122.9 kW 925 907 885 934 ;9.18. 900 940 9.24 912 TC 127.0 115.7 102.9 132.3 122.1 110 4 134.9 125 6 118 3 105 SHC 64.6 80.8 94.2 71.7 92 9 109.2 77 8 104.0 118.2 kW 1025 1009 986 1036 1017 1001 1041 1025 1015 TC 121 0 110.7 98 2 126.1 118.3 105 3 129.1 119 8 113 4 115 SHC 62.4 78 5 91.0 69 5 90.8 105 3 76.1 101.8 113.2 kW 11.34 11 19 10 95 11 47 11 31 11 11 11.55 11 37 11 28 BF Edb ENT Ewb kW SHC TC Standard Ratings LEGEND - Bypass Factor - Entering Dry Bulb - Entering - Entering Wet Bulb - Compressor Motor Power Input - Sensible Heat Capadty (1000 Btuh) Gross - Total Capacity (1000 Btuh) Gross 48HJ009 (81 /a TONS) Teir EMp Condenser (Edb) Temp (F) Air Entering Evaporator - Cfm /BF 2550/0.096 I 3400/0.13 4250/0.155 Temp (F) AIr Enter ng Evaporator - Ewb (F) 72 87 62 72 67 82 72 87 82 TC 115.3 105.9 97 4 120.0 110.8 102.7 122.8 113.5 108 4 85 SHC 57 0 70.9 84.4 63.0 80.6 97.3 67.9 89.4 106.1 kW 711 696 883 720 704 692 724 708 698 TC 110.6 102.3 92 7 114 8 1474 98 3 117.7 109.4 102.9 95 SHC 55.3 69.5 82.2 60.9.:;79:4:`: 95.0 65.9 87.9 102.9 kW 793 781 785 8.01 _`7.89:: 778 8.07 793 784 TC 1056 979 87.4 109.8 102.3 942 1115 1048 982 105 SHC 53.4 67.7 79.6 58.9 77.3 92.4 83.6 86.1 98.2 kW 882 873 8.55 892 881 866 894 884 871 TC 100.6 93 2 81 7 103 6 97 0 89 4 106.4 99 3 94 4 115 SHC 51.5 65.9 76.8 56.3 75.4 89.1 61.7 83.6 94.3 kW 979 968 951 985 975 963 992 980 970 NOTES: 1 Direct interpolation is permissible Do not extrapolate 2 The following formulas may be used: sensible capacity (Btuh) tldb = tedb 1,10 x cfm tlwb = Wet bulb temperature corresponding to enthalpy of air leaving evaporator coif (hlwb) total capacity (Btuh) hlwb hewb 4 5 x cfm Where: hewb = Enthalpy of air entering evaporator coil 3 The SHC is based on 80 F edb temperature of alr entering evaporator coil Below 80 F edb, subtract (corr factor x cim) from SHC Above 80 F edb. add (corr factor x cfm) to SHC. Correction Factor = 110 x (1 - BF) x (edb - 80) 15 FAN PERFORMANCE - VERTICAL DISCHARGE UNITS (cont) 48HJD /HJE006 (5 TONS) - STANDARD MOTOR AND DRIVE (BELT) AIRFLOW (Cfm) EXTERNAL STATIC PRESSURE (In. wg) 0.1 0.2 0.4 06 0.8 1.0 1.2 1.4 Rpm Bhp Rpm 1500 1800 1700 1800 1900 2000 2100 2200 2300 2400 2500 750 794 839 885 932 979 1026 1074 1122 1170 1218 .37 .44 .52 .61 72 83 98 1 10 1 25 1.42 1.61 808 846 884 924 965 1008 1051 1095 1140 1185 1231 Bhp 0.43 0.50 0.58 0 67 0.77 0.88 1 01 1.15 1 30 1 46 1 64 Rpm Bhp 914 0.57 950 0 65 983 0 73 1018 0.82 1057 0 94 1096 1.06 1136 1 19 1173 1 33 1210 1 47 1249 1.64 149 .1.81 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm 1.6 Bhp 1001 1034 1068 1105 1143 1177 1210 1245 1284 13223 . .1353; 0.70 0.78 0.88 0 99 1,12 1 24 1.37 1 51 1.87 1084 0,85 0 93 1145 1111 1 04 1179 1 15 1212 1 27 1247 1 41 1284 1.57 1 1AOz' 1424: ;2:24.: 1168 1194 1218 1246 1280 1300 1347 1380 :14780 1.02 111 1 20 1.32 1 45 ..174 190. 1199 1263 1295 1319 1343 .109 :144a 1)475. 111 1126 102 1.28 1275 1 35 1.40 1351 ..1.57 1.51 1389 1.72 ?:: 1.63 1415' 1.85 1:78 1 1 1.94 1 213 2.11 1488:; >a 31:.i 1352. . 1.62 :14w.. ^;5:6:. ' :1505 )ia9 :15u28 2.36 LEGEND Bhp - Brake Horsepower NOTES: 1 Boldface indicates field-supplied drive required (See Note 6 ) 2. Ealiacgrig indicates field- supplied motor and drive required 3 Maximum usable bhp Is 17 Extensive motor and electrical testing on the Weathermaster® units ensures that the full horsepower range of the motor can be utilized with confidence Using your fan motors up to the horsepower ratings shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. 4 Values include losses for filters, unit casing, and wet coils 5 Use of a field- supplied motor may affect wire sizing Contact Carrier representative to verify. 6 Motor drive range: 920 to 1300 rpm All other rpms require field - supplied drive 48HJD /HJE007 (6 TONS) - STANDARD MOTOR AND DRIVE (BELT) AIRFLOW (Cfm) EXTERNAL STATIC PRESSURE (In. wg) 0.1 0.2 0.4 06 0.8 1.0 1.2 1.4 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm 1.6 Bhp 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 935 982 1029 1076 1124 1171 1219 1267 1315 1363 1411 0.67 0.78 0.90 1 03 1 18 1 33 1 51 1 70 1 90 2 12 2.36 983 1027 1072 1117 1163 1209 1255 1301 1348 1395 0.75 1069 0.86 1111 0 98 1154 1 12 1197 1 27 1240 1 43 1283 1 61 1326 1 80 1370 2 00 1414 2 23. 1458' 247. 1 272:: I.18 0.91 1 03 1 16 1 31 1 47 1.64 1 82 2.02 2.23' 2.46 . 2,71 1152 1190 1228 1267 1307 1350 1392 1435 :tom :1521 1564 1 08 1 20 1 34 1.49 1.66 1 84 2 03 2.25 2.47 2.71: 1226 1 26 1263 1.40 1301 1 54 1338 1 69 1376 1 86 1414 204 .1453 2.24 15g a69. 1294 1 45 1330 1 59 1367 1 75 1403 1.91 1440 2.08 1478 2.27 1 16 .'2:47 j ,I592. .2-92 1358 1 64 1392 1 79 1428 1 96 1484 2.13 1500 2.31 .;t537 1574. 2.72: :1612 :2224: 1420 1452 1486 1521 1557 1y 1.85 2 00 2.17 2.35 2.78: 1486 2.11 1511 2.23 1542 . 2.39 :2:67 1690:' :277" 1648:: LEGEND Bhp - Brake Horsepower NOTES: 1. Boldface indicates field- supplied drive required. (See Note 6 ) 2 St d r indicates field - supplied motor and drive required 3 Maximum usable bhp Is 2 4 Extensive motor and electrical testing on the Weathermaster units ensures that the full horsepower range of the motor can be utilized with confidence. Using your fan motors up to the horsepower ratings shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected 4. Values include losses for filters, unit casing, and wet coils. 5 Use of a field- supplied motor may affect wire sizing Contact Carrier representative to verify 6 Motor drive range: 1070 to 1460 rpm. Alf other rpms require field - supplied drive • 17 FAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS 48HJE /HJF004 (3 TONS) STANDARD MOTOR AND DRIVE (BELT) AIRFLOW (Cfm) EXTERNAL STATIC PRESSURE (in. wg) 0.1 0.2 03 0.4 0.5 0.6 0.7 06 Rpm 900 1100 1200 1300 1600 754 823 Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm 0.9 Bhp 0.35 0.41 756 803 825 892 0 33 0 36 0 38 0 45 811 831 853 875 937 0 33 0 36 0 38 041 0 49 859 881 902 922 981 0 35 0 38 0 40 0 43 0 53 911 930 949 970 1029 0 37 0 40 0 43 0 47 0 60 981 979 999 1021 1054 0.39 0 43 0 47 051 0 70 1012 1032 1055 1072 0 42 0 47 051 0 57 1083 1090 1108 0 44 0 52 0 58 1122 1117 0 47 0 55 LEGEND Bhp - Brake Horsepower confidence Using your fan motors up to the horsepower ratings shown NOTES: will not result In nuisance tripping or premature motor failure Unit 1 Values Include losses for filters, unit casing, and wet coils. warranty will not be affected 2 Extensive motor and drive testing of the Weathermastere units ensures 3 Use of a field - supplied motor may affect wire sizing Contact Carrier that the full horsepower range of the motor can be utilized with representative to verify 48HJE /HJF004 (3 TONS) - ALTERNATE MOTOR (DIRECT) AIRFLOW (Cfm) LOW SPEED HIGH SPEED 208 230,460,575 208 230, 460, 575 ESP Bhp ESP Bhp ESP Bhp ESP Bhp 900 1000 1100 1200 1300 1400 1500 0 53 0.48 0 43 0 36 0 28 0 20 0 11 17 20 21 23 24 26 27 0 55 051 0 45 0 40 0 32 0 24 0 14 0 19 0 22 0 24 0 25 0 26 0 28 0 33 0.63 0 57 0.52 0 47 0.38 031 0.21 21 23 25 27 29 30 31 0 64 0 60 0 54 0 47 041 0 32 0 22 0 25 0.27 0 29 031 0 32 033 0 34 LEGEND Bhp - Brake Horsepower ESP - External Static Pressure NOTE: Values include losses for filters, unit casing, and wet coils 48HJD /HJE005 (4 TONS) - STANDARD MOTOR AND DRIVE (BELT AIRFLOW (Cfm) EXTERNAL STATIC PRESSURE (in. wg) 0.1 0.2 0.4 0.6 08 10 1.2 1.4 18 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 1.8 Bhp Rp m 1200 1300 1400 1500 1800 1700 1800 1900 2000 569 604 840 676 713 750 788 826 864 0.18 0.22 0.27 0.32 0.38 0.45 0.52 0.60 0 70 841 673 705 738 772 806 841 876 912 0.23 0.28 0.33 0.38 0.44 051 0 59 0 68 0 77 761 788 817 847 877 908 939 971 1004 .34 .39 45 51 58 66 .75 84 .94 859 887 914 940 967 997 1026 1056 1087 0 46 0.52 0 59 0 65 0 73 081 091 1 01 1 12 943 968 996 1024 1051 1077 1104 1132 1162 0 58 0 65 0.72 081 0.89 0 98 1 07 1.18 1.30 1030 1044 1069 1095 1123 1151 1178 1.204 1231 0 70 0 77 0 86 0 95 1 05 1.15 1.26 1;37 1.48 1155 1128 1139 1162 1188 '1243 t271 .1298 0 87 - 0 91 1245 0.99 1218 1.09 1228 1.20 1250 t 31 .11278 1 43 1303 1, 1 1.{89 1.10 1.14 1.24: 1.35 1.48 181 1.74 1.89 13'25 :1303 1 1386 :1413. :4:34 1.40 t 1 1486 1,60 1:68 1.95 2.11 . :227 LEGEND Bhp - Brake Horsepower NOTES: 1 Boldface Indicates field - supplied drive required (See Note 6.) 2 bhadingl indicates field - supplied motor and drive required 3 Maximum usable bhp is 13 Extensive motor and electrical testing on Weathermaster units ensures that the full horsepower range of the motor can be utilized with confidence Using your fan motors up to the horsepower ratings shown will not result in nuisance tripping or premature motor failure Unit warranty will not be affected 4 Values include losses for filters, unit casing, and wet coils 5. Use of a field - supplied motor may affect wire sizing Contact Carrier representative to verify 6. Standard motor drive range: 800 to 1130 rpm All other rpms require field - supplied drive 48HJD /HJE005 (4 TONS) - ALTERNATE MOTOR (DIRECT) AIRFLOW (Cfm) LOW SPEED HIGH SPEED 208 230,460,575 208 230,460,575 ESP Bhp ESP Bhp ESP Bhp ESP Bhp 1200 1300 1400 1500 1600 1700 1800 1900 2000 0 78 0 70 0 62 0 52 0 44 0 34 0 22 010 044 0 48 050 0 53 0 57 0.58 0 61 0.63 0 85 0 76 0 68 0 59 0 50 0 40 030 0 20 0 09 0 48 0 50 0.54 058. 0 60 0 63 0 65 0 68 0 69 92 84 78 69 61 53 45 37 .29 56 80 63 65 68 69 71 73 74 1 01 0 94 0 87 0 78 0 70 0 62 054 0 48 0 39 0 65 0 68 0 69 0 72 0 74 0 76 0 78 0 79 081 LEGEND Bhp - Brake Horsepower ESP - External Static Pressure NOTE: Values include losses for filters, unit casing, and wet coils 19 • FAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS (cont) 48HJD /HJE /HJF008, 009 (71/2 AND 81/2 TONS) AIRFLOW (Cfm) EXTERNAL STATIC PRESSURE (In. wg) 0.2 0.4 0 6 0.8 1 0 . 1.2 1.4 1.6 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 2200 2250 2300 2400 2500 2550 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 3600 3700 3750 3800 3900 4000 4100 4200 4250 4300 508 514 521 538 551 559 567 582 598 614 630 646 662 679 695 712 729 745 754 762 779 796 813 8'�r9 847 0.62 0.55 0.57 0.63 0.69 0.72 0.75 0.83 0 90 0 98 1 07 1 16 1 26 1 36 147 159 1 71 1 84 1.91 1 98 2.12 2 27 2.42 2. 2" 2.76 586 593 600 613 626 634 841 655 670 684 699 714 729 744 759 774 790 805 813 821 836 852 868 f a v ti, 01 U3 t■ 0 CO f, 1,1" 1.0 CD CO 0 Q) ts I , CO 01 CID 0 0 0 1— CV CO Xr(Drs ' 600060 ...wax,' A 11MS 656 662 668 680 693 700 706 719 732 745 759 773 787 801 816 830 845 '860 868 875:°;x.';; 890 �S:?iti r ?:: , it36::xx WOINMI■rMlnc9M.I.WODOON $1 CI5 al 0 0 01 Cr3 N: CO CD 01 el 40 akt• . I I 00 fmszo W.1.01-0M0NWa 1—NOVLOWWNW0,-NckinVA011 1...Ntst■NWWWWWW.• 1 18 1 22 1 26 1 34 1 43 1 48 1 52 161 1 71 1 81 1 92 2 04 216 2 29 2:42 2.56 2.71 2.87 ` +i}2C > .' :'�;3ii3? - - - - 776 781 786 796 808 814 819 831 842 854 866 878 $91 904 917 930 � r•;? Y~`'3:' - - .-- - - 1 43 1 78 1.50 1 59 1 69 1 74 1 79 189 2 00 2 11 2 23 2 35 2:48 2.61 2.75 2.90 - - - - - 838 841 843 849 859 864 869 880 892 993 915 926 938 <: 2 .. . ;19663:::: - "' - - - - - 1 78 1 81 1 83 1 88 1 96 2 01 2 06 217 2 29 2.42 2.54 2.67 2.81 i X333'•; ?% ':26 %k % - - - - - - - - coNooNLowilio,irir II(IIIIIIII ,,---j 2 21 2 25 2 28 2 31 2,31 2 34 2.37 2.47 2.58 2.71 2.85 f;.p$; D f fi''a.td. S ?; ' : c.:. �,.;:.:9.i168<:>. - - - - - - - - - - - 935 939 943 9 973 976 i ?; , .::`.�:;: '•>' = .. ›, ;• j - - - - - - - - - - - - - 2.58 2.60 2.62 2.74 2.81 2.81 2.81 2.84 2C" : <340: ; 443`r. :: rt r:3.4 :'r:, - - - - - - - - - - - - - - LEGEND Bhp - Brake Horsepower .NOTES: 1 .4hadingl indicates alternate motor required (See Note 7) 2. Boldface Indicates field - supplied drive required (See Note 7) 3 :I9 indicates field-supplied motor and drive required 4 Maximum usable bhp is 2 4 with the standard motor and 2 9 with the alternate motor Extensive motor and electrical testing on the Weathermastero units ensures that the full horsepower range of the motor can be utilized with confidence Using your fan motors up to the horsepower ratings shown will not result in nuisance tripping or premature motor failure Unit warranty will not be affected 5 Use of a field - supplied motor may affect wire sizing Contact Carrier representative to verify 6 Values include losses for filters, unit casing, and wet Coils 7 Standard motor drive range: 590 to 840 rpm. Alternate motor drive range: 840 to 1085 rpm All other rpms require field - supplied drive 48HJD/HJE012 (10 TONS) AIRFLOW (Cfm) EXTERNAL STATIC PRESSURE In. wg) 0.2 0.4 06 08 0.9 10 1.2 1.4 1.6 1.8 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 2. Rpm 0 Bhp 3000 3100 3200 3300 3400 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400 4500 4800 4700 4800 4900 5000 592 607 622 638 653 669 684 700 715 731 747 763 778 794 810 826 ,858. 874 0.76 661 0.93 722 109 779 126 0.83 676 1.01 734 1 17 791 1 34 0.90 690 109 746 125 803 1.43 0.98 705 117 759 133 815 1.52 1.08 719 126 772 143 826 1.62 1.15 733 135 786 1.53 838 172 1.24 747 1.44 800 1.64 850 182 133 760 1.54 814 175 863 192 1 43 774 1 64 828 1.86 875 2 04 1 54 787 1 74 843 1 98 888 2.16 1 64 801 1 85 857 2 10 902 2 30 1 76 816 1 97 872 2 23 .91S 2.44 1 88 831 2.10 886 2 36 929 2.58 2 00 846 2 23 900:::250 943 2.73 213 861 2.37 , 913. 264 958 289 878 2.27 576 2.32 tort 2 78 973 3.04 . 2.41 ' 892 2.87 340 940:. 2.92 : 987 :3.21 255. ;907.., 2.93 894 3.05i .1f02 :838 270` :. 299::958. 3.,4 2.86 998 3.16 3,03: (P3: 333 804 816 827 839 851 863 875 887 899 912 925 1.34 829 1 42 880 1 58 924 1 73 970 1 89 1019 200 1.42 840 1 51 890 168 935 1 84 977 2 00 1028 2 17 1 52 852 1 60 900 1.77 946 1 95 987 2 11 1029 2 28 1.61 864 1 70 910 188 957 2 06 998 2 23 1037 2.40 1 71 876 1.81 921 1 98 967 2 17 1009 2.35 '1947 '2.ta 1 81 888 1.91 933 210 . 976 229 1020. 248 ' 1058 :266 1 92 900 2 03 945 2 22 986 2.41 1030 261 ; 1069 ' 2.80' 2.03 912 2 14 957 2.34 998 2.54. 1039 2.74 1081 2.94 215 924 2 26 969 .247 1010 2.67 1049 :2.87 , 1091 9.08 2 27 936 238 981. 280 1 ••• .:2.81 1060 13.02 1100 323 2.40 .9138. 2.51.:.:993 274 :t•K .2.96 10723.17 ,1110 3,38, 254.. 960 2.64.. 1005 2'88: : 1046-3:11 ;1A$4 3.32 - - 2.68 972 2.78 1018 3,03 1058. 328 - - 2,�}i 985 293. 1028 3;17. 2.99. 993 3.09 1040. 3,32 : 3.15 1012 3.26 1066 2.30 1070 2rn4 f 1075 2.51 1 1082 2.58 1037 ,2.70 1095 2.84 1106 2.98 1117 3.13 1 1128 3191 LEGEND Bhp - Brake Horsepower NOTES: 1 Boldface indicates field - supplied drive required 2 Shadfrsgj indicates alternate motor required (See Note 6 ) 3. Maximum usable bhp is 24 with the standard motor and 4 2 with the alternate motor Extensive motor and electrical testing on the Weathermaster units ensures that the full horsepower range of the motor can be utilized with confidence Using your fan motors up to the horsepower ratings shown will not result in nuisance tripping or premature motor failure Unit warranty will not be affected 4 Use of field- supplied motor may affect wire sizing Contact Carrier representative to verify 5 Values include losses for filters, unit casing, and wet coils 6 Standard motor drive range: 690 to 935 rpm Alternate motor drive range: 860 to 1080 rpm All other rpms require field - supplied drive 21 i�ARI — A'r Conditioning and Re rigeration Institute Bels— Sound Levels (1 bel = 10 decibels) ALTITUDE COMPENSATION' — 48HJ004 -007 ELEVATION NATURAL GAS Orifice Slzet LIQUID PROPANE Orifice Size 0 -2,000 33 43 2,000 34 43 3,000 35 44 4,000 36 44 5,000 36 44 6,000 37 45 7,000 37 45 8,000 38 46 9,000 39 47 10,000 41 48 11,000 43 48 12,000 44 49 13,000 44 49 14,000 45 50 'As the height above sea level increases there is less oxygen per cubic foot of air. Therefore, heat input rate should be reduced at higher altitudes tOrifices available through your Carrier Distributor. SOUND POWER (Total Unit) 48HJ ARI RATING (60 Hz) OCTAVE BANDS 63 125 250 500 1000 2000 4000 8000 004-006 8.0 Bels 63 2 69 5 70.0 73.7 73 5 70.6 66.7 60.3 007 8.2 Bels 78 5 84.0 77.5 73 0 70 5 72 0 65 0 58 5 008 -012 8.6 Bels 63 7 69.9 72.5 78.2 81.1 77.3 73.3 66.8 • ECONOMIZER/TWO POSITION DAMPER BAROMETRIC RELIEF DAMPER CHARACTERISTICS — 48HJ004 -012 PRESSURE DROP (tn. wg ) 0 30 025 020 015 010 0 05 000 0 50 100 150 200 250 300 350 400 450 500 550 CFM ALTITUDE COMPENSATION' — 48HJ008-012 ELEVATION NATURAL GAS Orifice Sizet LIQUID PROPANE Orifice Size 0 -2,000 31 41 2,000 32 42 3,000 32 42 4,000 32 42 5,000 33 43 6,000 34 43 7,000 35 44 8,000 36 44 9,000 37 45 10,000 38 46 11,000 39 47 12,000 40 47 13,000 41 48 14,000 42 48 *As the height above sea level increases there is less oxygen per cubic foot of air. Therefore, heat input rate should be reduced at higher altitudes. tOrifices available through your Carrier Distributor. ALTITUDE DERATING FACTOR" — 48HJ004 -012 ELEVATION MAXIMUM HEATING VALUE (Btu /ft ) 0 -2000 1100 2001 -3000 1050 3001 -4000 1000 4001-5000 950 5001 -6000 900 *Derating of the uni Is not required unless the heating value of the gas exceeds the values listed in the table above, or if the elevation ex- ceeds 6000 ft Derating conditions must be 4% per thousand ft above sea level. For example, at 4000 ft, if the heating value of the gas exceeds 1000 Btu /ft', the unit will require a 16% derating. For elevations above 6000 ft, the same formula applies For example, at 7000 ft, the unit will require a 28% derating of the maximum heating value per the National Fuel Gas Code. 23 • Typical piping and wiring VERTICAL DISCHARGE DUCTING HINGED FILTER ACCESS DOOR CONDENSER -FAN DISCHARGE AIR CONDENSATE DRAIN (FACTORY- SUPPLIED INTERNAL P -TRAP) SUPPLY AIR ECONOMIZER/TWO-POSITION DAMPER TERMINAL BOARD FIELD - SUPPLIED DISCONNEC PER NEC CONDENSER COIL AIR INLET POWER WIRING SLAB MOUNT RETURN AIR ROOF CURB HORIZONTAL DISCHARGE DUCTING CONDENSER -FAN DISCHARGE AIR OUTDOOR -AIR INLET OUTDOOR - AIR HOOD LEGEND ___> OUTDOOR AIRFLOW 1=> INDOOR AIRFLOW CONTROL WIRING NEC — National Electrical Code COMPRESSOR MANUAL GAS FROM MAIN VALVE GAS SUPPLY HEAT EXCHANGER 25 • • Controls Operating sequence Cooling, units without economizer — When thermo- stat calls for cooling, terminals G and Y1 are energized. The indoor (evaporator) fan contactor (IFC), compressor contac- tor no. 1 (C1) and outdoor (condenser) fan contactor (OFC) (48HJ008 -012 units) are energized and evaporator fan motor, compressor na 1 and condenser fan start. The condenser -fan motor runs continuously while unit is cooling. On 008-012 units, if the thermostat calls for a second stage of cooling by energizing Y2, compressor contactor na 2 (C2) is energized and compressor no. 2 starts. Heating, units without economizer — When thermo- stat calls for heating, terminal W1 is energized, induced draft relay (IDR) is energized and burner ignition sequence begins. When time delay sequence is complete (55 ± 10 seconds af- ter W1 is energized) indoor (evaporator) fan contactor (IFC) is energized and evaporator -fan motor starts. On size 008 -012 units equipped for 2 stages of heat, when additional heat is needed, W2 is energized and the high -fire solenoid on the main gas valve is energized. When the thermostat is satisfied and W1 is deenergized, evaporator -fan motor remains on for 45 ± 15 seconds. Cooling, units with economizer — When the outdoor ambient temperature is above the outdoor-air thermostat (OAT) or enthalpy control setting and the thermostat calls for cooling, terminals G and Y1 are energized. The indoor (evaporator) fan contactor (IFC) is energized and the econo- mizer damper blade opens to the minimum position, com- pressor contactor no. 1 (C1) and outdoor (condenser) fan contactor (OFC) (48HJ008 -012 units only) are energized and evaporator -fan motor, compressor no. 1 and condenser fan start. On 008 -012 units, if thermostat calls for a second stage of cooling by energizing Y2, compressor contactor no. 2 (C2) is energized and compressor no. 2 starts If the outdoor ambient temperature is below the OAT set- ting and the thermostat calls for cooling, the IFC is energized, the evaporator fan is started and the economizer modulates open. The economizer acts as the first stage of cooling, pro- viding free cooling with outdoor air. The position of the damper blade is determined by the discharge air thermistor. If outdoor air alone cannot satisfy the cooling requirements of the conditioned space, Y2 on the thermostat is energized and compressor no. 1 starts. The damper blade opens for 5 seconds and stops for 30 seconds until fully open. As conditioned space temperature approaches the thermo- stat's cooling set point, the mechanical cooling stage cycles off. After mechanical cooling shuts off, the economizer mod- ulates to the minimum position. Heating, units with economizer — Upon a call for heat through Wl, the induced draft relay is energized to start the induced draft motor. The main burner lights, the IFC ener- gizes to start the evaporator fan, and the economizer damper blade opens to the minimum position. If the two - position damper is used, the outdoor -air damper opens to the mini- mum position whenever the evaporator fan runs. On 008-012 units equipped with 2 stages of heat, when additional heat is needed, W2 is energized and the high fire solenoid on the main gas valve is energized. After W1 is deenergized, the evaporator -fan motor contin- ues to run for 45 ± 15 seconds. As space temperature approaches the heating temperature set point, heating stage cycles off. The economizer or two - position damper returns to a fully closed position when fan shuts off. 27 • • AHA C CB CC CLO COM DAT EC ECON EMC /EMFC EMFC.L EMO /EMFO FPT FU GND HC HPS HR ICP IDR IFC LPS LS MGV MTR MV NC NO OAT P PL PS RES RS SEN SW1 SW2 LEGEND FOR TYPICAL CONTROL WIRING SCHEMATIC — Adjustable Heat Anticipator — Compressor Contactor — Circuit Breaker — Cooling Compensator — Compressor Lockout — Common — Discharge Air Thermistor — Enthalpy Control — Economizer — Energy Management Closed (Economizer) — Energy Management Fully Closed (Two - Position Damper) — Energy Management Open — Freeze Protection Thermostat — Fuse — Ground — Heater Contactor (Strip Heat) — High- Pressure Switch — Heater Relay — Ignitor — Ignitor Control Pack — Induced Draft Relay - Indoor (Evaporator) Fan Contactor — Loss -off - Charge /Low- Pressure Switch — Limit Switch (Manual Reset) — Main Gas Valve — Motor — Main Valve — Normally Closed — Normally Open — Outdoor -Air Thermostat — Plug — Plug Assembly — Pressure Switch — Resistor Rollout Switch — Sensor — Switch, Fully Open — Switch, Fully Closed SW3 SW4 TB TC TDR TH TRAN • O x — Switch, Minimum Vent Position — Switch, Maximum Vent Position — Terminal Block — Thermostat, Cooling — Time Delay Relay — Thermostat, Heating — Transformer Circuit Board Run Field Splice Marked Wire Terminal (Marked) Terminal (Unmarked) Terminal Block Terminal Econ Two- Positlon Board Splice Splice (Marked) Factory Wiring Field Control Wiring Field Power Wiring Accessory or Optional Wiring To indicate common potential only. Not to represent wiring 29 F. Heating Section: 1. Induced draft combustion type with energy saving direct spark ignition system and redundant main gas valve. 2. The heat exchanger shall be of the tubular section type constructed of a minimum of 20 gage steel coated with a nominal 1.2 mil aluminum - silicone al- loy for corrosion resistance. 3. Burners shall be of the in -shot type constructed of aluminum coated steel. 4. All gas piping shall enter the unit cabinet at a single location. G. Refrigerant Components: Refrigerant circuit components shall include: 1. AcutrolTM multiple independent circuit feed system. 2. Filter drier to eliminate any moisture or foreign matter. 3. Service gage connections on suction, discharge, and liquid lines to charge, evacuate, and contain re- frigerant. H Filter Section: 1. Standard filter section shall consist of factory -in- stalled low velocity, disposable 2 -in. thick fiberglass filters of commercially available sizes. 2. Filter face velocity shall not exceed 320 fpm at nom- inal airflows. 3. Filter section should use only one size filter. [ Controls and Safeties - 1. Unit Controls: Unit shall be complete with self contained low volt- age control circuit protected by a manually resetta- ble circuit breaker on the 24 -v transformer side. 2. Safeties. a. Unit shall incorporate a solid -state compressor protector which provides reset capability at the space thermostat, should any of the following standard safety devices trip and shut off com- pressor: 1) Compressor overtemperature, overcurrent. 2) Loss -of- charge/low- pressure switch. 3) Freezestat, evaporator coil. 4) High - pressure switch. The lock -out protection shall be easily discon- nected at the control board, if necessary. b. Heating section shall be provided with the fol- lowing minimum protections: 1) High - temperature limit switch. 2) Induced draft motor pressure switch. 3) Flame rollout switch (manual reset). 4) Flame proving controls. J. Operating Characteristics: 1. Unit shall be capable of starting and running at 125 F ambient outdoor temperature, exceeding maximum load criteria of ARI Standard 210/240. 2. Compressor with standard controls shall be capable of operation down to 25 F ambient outdoor tem- perature. 3. Unit provided with fan time delay to prevent cold air delivery before heat exchanger warms up. K. Electrical Requirements: All unit power wiring shall enter unit cabinet at a single factory - predrilled location L. Motors: 1. Compressor motors shall be cooled by suction gas passing through motor windings and shall have line break thermal and current overload protection. 2. Indoor blower motor shall have permanently lubri- cated bearings and inherent automatic reset thermal overload protection. 3 Outdoor totally enclosed motor shall have perma- nently lubricated bearings, and inherent automatic reset thermal overload protection. 4. Induced draft motor shall have permanently lubri- cated sealed bearings and inherent automatic reset thermal overload protection. M. Special Features: Certain features are not applicable when the features designated by * are specified. For assistance in amend- ing the specifications, your local Carrier Sales Office should be contacted. 1. Roof Curb. a. Formed galvanized steel with wood nailer strip and capable of supporting entire unit weight. b. Allows for installing and securing ductwork to curb prior to mounting unit on the curb. * 2. Integrated Economizer. a. Integrated type capable of simultaneous econo- mizer and compressor operation. b. Includes all hardware and controls to provide cooling with outside air c. Equipped with a single sliding -plate low leakage type damper. d. Capable of introducing up to 100% outdoor air. e. Equipped with a gravity relief damper. * 3. Manual Damper: Manual damper package shall consist of damper, birdscreen, and rainhood which can be preset to admit up to 50% outdoor air for year round ventilation. * 4 Two-Position Damper: a. Two - position damper package shall include sin- gle blade damper and motor. Admits up to 50% outdoor air b. Damper shall close upon indoor fan shutoff. * 5. Optional Compressor Cycle Delay: Compressor shall be prevented from restarting for a minimum of 5 minutes after shutdown * 6. Solid -State Enthalpy Control: a. For use with economizer package only. b. Capable of sensing outdoor -air heat content (temperature and humidity) and control econo- mizer cut -in point to have minimum heat content air passing over the evaporator coil for most effi- cient system operation. 31 Guide specifications — 48HJ008 -012 Packaged Rooftop Cooling Unit with Gas Heat — Constant Volume Application HVAC Guide Specifications Size Range: 71/2 to 10 Tons, Nominal (Cooling) 120,000 to 225,000 Btuh, Nominal (Input Heating) Carrier Model Number: 48HJD 48HJE 48HJF Part 1 — General 1.01 SYSTEM DESCRIPTION A. Outdoor rooftop mounted, electrically controlled heat- ing and cooling unit utilizing a scroll compressor for cooling duty and gas combustion for heating duty. Unit shall discharge supply air vertically or horizontally as shown on contract drawings. 1.02 QUALITY ASSURANCE A. Unit shall be rated in accordance with ARI Standards 210/240 or 360 and 270. Designated in accordance with UL Standard 1995. B. Unit shall be designed to conform to ANSI/ASHRAE 15 -1978. C Unit shall be UL tested and certified in accordance with ANSI Z21.47 Standards and CSA certified as a total package. D. Roof curb shall be designed to conform to NRCA Standards E. Insulation and adhesive shall meet NFPA 90A require- ments for flame spread and smoke generation. F. Unit casing shall be capable of withstanding Federal test Method Standard Na 141 (Method 6061) 500 - hour salt spray test. 1.03 DELIVERY, STORAGE, AND HANDLING A. Unit shall be stored and handled per manufacturer's recommendations. Part 2 — Products 2.01 EQUIPMENT (STANDARD) A. General: Factory assembled, single -piece heating and cooling unit. Contained within the unit enclosure shall be all factory wiring, piping, controls, refrigerant charge (R -22), and special features required prior to field start- up. B. Unit Cabinet: 1. Unit cabinet shall be constructed of galvanized steel, bonderized and coated with a prepainted baked enamel finish on all externally exposed sur- faces, with primer coated internal panels. 2. Indoor blower (evaporator fan) compartment inte- rior cabinet surfaces shall be insulated with a mini- mum 1 /2 -in. thick, flexible fiberglass insulation, coated on the air side. Aluminum foil faced fiberglass insulation shall be used in the furnace compartment. 3. Cabinet panels shall be easily removable for servic- ing. 4. Filters (2 in.) will be accessible through a hinged ac- cess door, and will require no panel or screw re- moval 5. Holes shall be provided in the base rails for rigging shackles to facilitate maneuvering and overhead rig- ging. 6. Unit shall have a factory - installed internally trapped condensate drain made of a non - corrosive material, providing a minimum 3 /4-in. connection. Unit is shipped for a horizontal condensate drain, but is field convertible to vertical condensate drain if nec- essary. Condensate pan shall conform to ASHRAE Standard 62. C Fans: 1. Indoor blower (evaporator fan): a. Fan shall be belt driven as shown on the equip- ment drawings. Belt drive shall include an adjust- able -pitch motor pulley. b. Fan wheel shall be double -inlet type with for- ward- curved blades which are statically and dy- namically balanced. c. Bearings shall be sealed, permanently lubricated ball- bearing type for longer life and lower mainte- nance. 2. Indoor blower (evaporator fan) shall be made from steel with a corrosion resistant finish and shall be dynamically balanced. 3. Outdoor (condenser) fan shall be of the direct driven propeller type and shall discharge air vertically up- wards. 4. Outdoor (condenser) fan shall be totally enclosed with permanently lubricated bearings. 5. Outdoor (condenser) fan shall have aluminum blades riveted to corrosion resistant steel spiders and shall be dynamically balanced. 6. Induced draft blower shall be of the direct driven sin- gle inlet forward - curved centrifugal type, made from steel with a corrosion resistant finish and shall be dynamically balanced. D. Compressor: 1. Fully hermetic type, on independent circuits and in- ternally protected with internal high- pressure relief. 2. Factory rubber shock mounted and internally spring mounted on independent dedicated rails for vibra- tion isolation. 3. Equipped with a factory installed crankcase heater to minimize liquid refrigerant accumulation in com- pressor during shutdown and prevent refrigerant di- lution of oil. E. Coils: 1. Evaporator and condenser coils shall have alumi- num plate fins mechanically bonded to seamless copper tubes with all joints brazed and degreased at the factory. 2. Tube sheet openings shall be belled to prevent tube wear. F. Heating Section: 1. Induced draft combustion type with energy saving direct spark ignition system and redundant main gas valve. 33 * 7. Differential Enthalpy Sensor. a. For use with economizer only. b. Capable of comparing heat content (tempera- ture and humidity) of outdoor air and return air and controlling economizer cut -in point at the most economical level. * 8. Head Pressure Control Package a. Consists of solid -state control and condenser temperature sensor for head pressure control. b. Capable of controlling outdoor fan motor cy- cling to maintain condensing temperature be- tween 90 F and 110 F at outdoor ambient temperatures down to — 20 F. * 9. Remote Control Panel: Panel shall be a decorative, indoor, wall- mounted panel consisting of: a. Two -stage heat /2 -stage cool thermostat. b. Automatic changeover c. System switch with HEAT-COOL-AUTO.-OFF settings. d. Fan switch with ON -AUTO. settings. e. Indicator lights for HEAT-COOL-FAN opera- tion. f. Three unused indicator lights for field use. * 10. LP Gas Kit: Package shall contain all the necessary hardware and instructions to convert a standard natural gas unit for use with liquefied propane gas. 11. Thru- the -Curb Service Connections: Allow gas and electrical connections to be brought to the unit through the roof curb. * 12. Electronic Programmable Thermostat: Capable of using deluxe full- featured electronic thermostat. 13. Flue Shield: Provides protection from the hot sides of the gas flue hood. * 14. Thermostat and Subbase: Provides staged cooling and heating automatic (or manual) changeover, fan control, and indicator light. 15. Hail Guard: Hail guard shall protect against damage from hail and flying debris. 16. NOX Reduction Kit: Package shall contain all necessary hardware and instructions to convert a standard natural gas unit to reduce the nitrous oxide (NOX) emissions to a level of 40 nanograms /joule. 17 Flue Discharge Deflector: Package shall contain single -piece deflector and hardware to exhaust the flue discharge up and away from unit. The flue discharge deflector shall allow minimum flue side clearances to combusti- bles to be reduced to 18 inches. 35 LENNOX) FILE COPY PRODUCT SPECIFICATIONS ENERGENCE® Saving Energy with Intelligence'" PACKAGED GAS ELECTRIC LGH Energence® Rooftop Units 60 HZ Bulletin No. 210540 January 2012 Supersedes October 2011 PRODIGY „, SMARTWIRETM SYSTEM CONTROL SYSTEM H u m i d i t r o l L Connection- L - » ' ComercialEneURCE N E T W O R K ASHRAE 90.1 COMPLIANT ENERGY STAR 3 to 6 Tons Net Cooling Capacity - 34,800 to 72,000 Btuh Gas Input Neat Capacity - 65,000 to 150,000 Btuh MODEL NUMBER IDENTIFICATION I Brand/Family 1 L = Energence LGH060H4ESIY Unit Type I G = Packaged Gas Heat w/ Electric Coding I Major Design Sequence H = 1st Generation REVIEWED FOR CODE COMPLIANCE. APPROVED OCT 2 fi 2012 mina! Cooling Capacity - Tons 036 = 3 Tons 048 = 4 Tons 060 = 5 Tons 072 = 6 Tons City of Tukwila BUILDING DIVISION Cooling Efficiency S = Standard Efficiency H = High Efficiency I Refrigerant Type I 4 = R-410A Voltage P = 208/230V -1 phase -60hz Y = 208/230V -3 phase -60hz G = 460V -3 phase.60hz J = 575V -3 phase -60hz Minor Design Sequence 1 = 1st Revision 2 = 2nd Revision 3 = 3rd Revision Heating type S = Standard Gas Heat, 1 stage M = Medium Gas Heat, 1 stage H = High Gas Heat, 2 Stage T = High Gas Heat, 1 Stage U = Medium Gas Heat, 2 Stage Q = Medium Gas Heat, 2 Stage, Low NOx RECEIVED . Yl= MediumrGas Heat, 1 Stage, Low NOOx C+� ! i OF TUK ” LA X = High Gas Heat, 2 Stage, Low NOx Z = High Gas Heat, 1 Stage, Low NOx Blower Type E = Direct Drive (ECM) T = Belt Drive (2 Speed) B = Belt Drive (1 Speed) OCT, 0`+2012 PERMIT CENTER FEATURES AND BENEFITS Lennox' Energence® packaged rooftop unit product line was created to save energy with intelligence by offering some of the highest energy efficiency ratings available with a powerful, easy to use unit controller. This makes Energence rooftop units perfect for business owners looking for an HVAC product with the lowest total cost of ownership. Energence rooftop units feature: • ECM Blower And Condenser Fan Motors - Direct drive units features ECM blower and condenser fan motors to allow energy efficient MSAVTM (multi -stage air volume) operation during all operating conditions. Blower setpoints can be easily set in the field through the Prodigy Unit Controller reducing setup time. • Two -Stage Scroll Compressor - All 3 to 5 ton models feature a two -stage scroll compressor which allows Energence rooftop units to deliver just the necessary amount of cooling needed to meet the space's demand. Single speed scroll compressor is furnished on 6 ton models. • Hinged Access Panels - Provide quick access to components and protect panels and roof from damage during servicing. • Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting airflow. • Corrosion - Resistant Removable, Reversible Drain Pan - Provides application flexibility, durability and improved serviceability. • Thermostatic Expansion Valves - Provide peak cooling performance across the entire application range. • Humiditrol® Dehumidification System Option - Patented system allows for independent control of temperature and humidity, providing enhanced comfort control. • MERV 13 Filters - Available as factory or field option, provide an enhanced level of indoor air quality, and can help the building qualify for additional LEED credits. • Foil -Faced Insulation - Insulation on all internal surfaces that have contact with airflow helps minimize airborne fibers and improve IAQ. Prodigy® Control System Standard on every Energence rooftop unit, the new Prodigy® unit controller is the heart of the Lennox® controls offering. The intuitive user interface makes setup, troubleshooting and service easier than ever. Each unit tracks the runtime of every major component and records the date and time when service or maintenance is performed. The unit controller intelligently operates the rooftop unit SmartWireT"" System The Smartwire system simplifies field sensor or thermostat installation through advanced connectors that are keyed and color -coded to help prevent miswiring. Not only is the wire coloring scheme standardized across all models, each connection is intuitively labeled to make troubleshooting and servicing quick and easy. Energence® Packaged Gas 1 Electric 3 to 6 Ton / Page 2 FEATURES AND BENEFITS CONTENTS Accessory Dimensions Blower Data Cooling Ratings Dimensions Electrical Data Features And Benefits High Altitude Derate Humiditrol® Dehumidification System Ratings Optional Conventional Temperature Control Systems Options / Accessories Prodigy® Control System Sequence Of Operation Specifications - Belt Drive Specifications - Direct Drive Specifications - Gas Heat 49 28 22 48 41 2 18 26 45 13 7 19 17 16 18 Sunsource® Commercial Energy System 10 Unit Clearances 47 Weight Data 46 APPROVALS AHRI Certified to AHRI Standard 210/240 -2008 (3 thru 5 ton models) and AHRI Standard 340/360 -2007 (6 ton models). ETL and CSA listed. Efficiency rating certified by CSA. Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National and Canadian Electrical Codes. All models are ASHRAE 90.1 -2007 compliant. ENERGY STAR® certified units are designed to use less energy, help save money on utility bills, and help protect the environment. The ENERGY STAR® Partner of the Year Award signifies that Lennox has made outstanding contributions to design energy efficient units that will lower energy bills, while meeting industry standards for comfort and indoor air quality. Lennox was the first HVAC manufacturer to win this award and has been a four -time recipient since 2003. ISO 9001 Registered Manufacturing Quality System. Dealer Design Award Lennox has received the Dealer Design Award from an independent panel of dealer- contractors selected by Air Conditioning, Heating & Refrigeration News ( "The News ") magazine. Their decision is based on "best in categories" of installation, maintenance and service as well as quality and performance. WARRANTY Limited ten years aluminized heat exchanger, limited fifteen years optional stainless steel heat exchanger. Limited five years on compressors. Limited three years on Prodigy® Unit Controller. Limited one year all other covered components. HEATING SYSTEM 0 Aluminized steel inshot burners, direct spark ignition, electronic flame sensor, combustion air inducer, redundant automatic single or dual stage gas valve with manual shut -off. Heat Exchanger Tubular ► construction, aluminized steel, life cycle tested. Stainless Steel Heat Exchanger is required if mixed air temperature is below 45 °F. Limit Controls Factory installed, redundant limit controls with fixed temperature setting. Heat limit controls protect heat exchanger and other components from overheating. Safety Switches Flame roll -out switch, flame sensor and combustion air inducer proving switch protect system operation. All safety switches are monitored by the Prodigy® Unit Controller and diagnostic information is reported and recorded. Low NOx Models All models are available in low NOx versions. R41 OA' REQUIRED SELECTIONS Gas Input Choice - Order one: • Standard Gas Heat (1 Stage) 65,000 Btuh (Not available for 090 models) • Medium Gas Heat (1 Stage) 105,000 Btuh • Medium Gas Heat (2 Stage) 73,500/105,000 Btuh • High Gas Heat (1 Stage) 150,000 Btuh • High Gas Heat (2 Stage) 105,000/150,000 Btuh Standard or Low NOx Specify standard gas heat or low NOx option. Energence° Packaged Gas 1 Electric 3 to 6 Ton / Page 3 *FEATURES AND BENEFITS HEATING SYSTEM (CONTINUED) OPTIONS /ACCESSORIES Factory Installed Stainless Steel Heat Exchanger Required if mixed air temperature is below 45 °F. Factory or Field Installed Low Temperature Vestibule Heater Extends gas heat operation from -40 °F (standard) down to -60 °F. Electric heater automatically controls minimum temperature in gas burner compartment when temperature falls below -40 °F. Field Installed Combustion Air Intake Extensions Recommended for use with existing flue extension kits in areas where high snow can block intake air. LPG /Propane Kits Conversion kit to field change over units from Natural Gas to LPG/ Propane. Vertical Vent Extension Kit Use to exhaust flue gases vertically above unit. Required when unit vent is too close to fresh air intakes per building codes. The vent kit also prevents ice formation on intake louvers. Kit contains vent transition, drain cap and installation hardware. NOTE - Straight vent pipe (3 in. B- Vent), vent tee and vent cap are not furnished and must be field supplied. Refer to kit instructions for additional information. COOLING SYSTEM Designed to maximize sensible and latent cooling performance at design conditions. System can operate from 0 °F to 125 °F without any additional controls. R-410A Refrigerant Non - chlorine based, ozone friendly, R -410A. ® Copeland Scroll Ultra Tech"' Two -Stage Compressor (3 to 5 Ton Models) Scroll compressors on all models for high performance, reliability and quiet operation. Two -stage scroll compressors are furnished on 3 to 5 ton models for increased part load efficiency. Single speed scroll furnished on 6 ton models. Resiliently mounted on rubber grommets for quiet operation. Compressor Crankcase Heater Protects against refrigerant migration that can occur during low ambient operation. Thermal Expansion Valve Assures optimal performance throughout the application range. Removable element head. Filter /Drier High capacity filter /drier protects the system from dirt and moisture. High Pressure Switch Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or Toss of outdoor fan operation. Low Pressure Switch Protects the compressor from low pressure conditions such as low refrigerant charge, or low /no airflow. Freezestat Protects the evaporator coil from damaging ice build -up due to conditions such as low /no airflow, or low refrigerant charge. 0 Coil Construction Copper tube construction, enhanced rippled -edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested. Evaporator Coil Cross row circuiting with rifled copper tubing optimizes both sensible and latent cooling capacity. Condenser Coil Two independent formed coils allow separation for cleaning. Energence® Packaged Gas / Electric 3 to 6 Ton / Page 4 Condensate Drain Pan Plastic pan, sloped to meet drainage requirements ofASHRAE 62.1. Side or bottom drain connections. Reversible to allow connection at back of unit. 0 Variable Speed Outdoor Coil Fan Motor Variable speed (ECM) fan motor for energy efficient MSAVTM' (multi- stage air volume) operation and quiet operation. Thermal overload protected, totally enclosed, permanently lubricated ball bearings, shaft up, wire basket mount. Outdoor Coil Fan PVC coated fan guard furnished. REQUIRED SELECTIONS Cooling Capacity Specify nominal cooling capacity of the unit Cooling Efficiency (3 to 5 Ton models only) Specify either standard or high efficiency. OPTIONS /ACCESSORIES Factory Installed Service Valves Fully serviceable brass valves installed in discharge & liquid lines. Not available for units equipped with Humiditrol option. Factory or Field Installed Condensate Drain Trap Field installed only, may be factory enclosed to ship with unit. Available in copper or PVC. Drain Pan Overflow Switch Monitors condensate level in drain pan, shuts down unit if drain becomes clogged. FEATURES AND BENEFITS CABINET ® Construction Heavy -gauge steel panels and full perimeter heavy -gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation. Base rails have rigging holes. Three sides of the base rail have forklift slots. Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building. Airflow Choice Units are shipped in downflow (vertical) configuration, can be field converted to horizontal airflow configuration without any optional kits. Duct Flanges Provided for horizontal duct attachment. Power /Gas Entry Electrical and gas lines can be brought through the unit base or through horizontal access knock- outs Exterior Panels Constructed of heavy- gauge, galvanized steel with a two -layer enamel paint finish. Insulation All panels adjacent to conditioned air are fully insulated with non - hygroscopic fiberglass insulation. Unit base is fully insulated. The insulation also serves as an air seal to the roof curb, eliminating the need to add a seal during installation. Access Panels Hinged tool -less access panels are provided for the economizer /filter section, and compressor /controls section. All hinged panels have seals and quarter -turn latching handles to provide a tight air and water seal. REQUIRED SELECTIONS Airflow Configuration Specify horizontal or downflow. OPTIONS /ACCESSORIES Factory Installed Corrosion Protection A completely flexible immersed coating with an electrodeposited dry film process. (AST ElectroFin E -Coat) Meets Mil Spec MIL -P- 53084, ASTM B117 Standard Method Salt Spray Testing. Indoor Corrosion Protection: - Coated coil - Coated reheat coil (Humiditrol) - Painted blower housing - Painted base Outdoor Corrosion Protection: - Coated coil - Painted base Field Installed Coil Guards Painted, galvanized steel wire guards to protect outdoor coil. Not used with Hail Guards. Hail Guards Constructed of heavy gauge steel, painted to match cabinet, helps protect outdoor coils from hail damage. Not used with Coil Guards. BLOWER A wide selection of supply air blower options are available to meet a variety of airflow requirements. Blower Motor Choice Overload protected, equipped with ball bearings. Variable -speed ECM direct drive motors are offered on 036, 048 and 060 models. Belt drive motors with two -speed capability (low static /high static) are available on 036, 048 and 060 models in several different sizes to maximize air performance. Single speed belt drive motors are available in different sizes to meet static requirements on 072 models. ® Supply Air Blower Forward curved blades, blower wheel is statically and dynamically balanced. All belt drive motors have adjustable pulley for speed change. Ordering Information Specify motor horsepower and drive kit number when base unit is ordered. REQUIRED SELECTIONS Order one drive kit, see Drive Kit Specifications Table. OPTIONS /ACCESSORIES Factory Installed Blower Belt Auto Tensioner Provides proper tension to belt drive blower belt without the need for regular adjustments. Maintains airflow and proper performance. Energence° Packaged Gas / Electric 3 to 6 Ton / Page 5 • FEATURES AND BENEFITS ELECTRICAL REQUIRED SELECTIONS Voltage Choice Specify when ordering base unit. OPTIONS /ACCESSORIES Factory Installed Circuit Breakers HACR type. For overload and short circuit protection. Factory wired and mounted in the power entry panel. Current sensitive and temperature activated. Manual reset. PhaseNoltage Detection (3 Phase models only) Phase detection monitors power supply to assure phase is correct at unit start-up. If phase is incorrect, the unit will not start and an alarm code is reported to the unit controller. Protects unit from being started with incorrect phasing which could lead to issues such as compressors running backwards. Voltage detection monitors power supply voltage to assure proper voltage. If voltage is not correct (over /under voltage conditions) the unit will not start and an alarm code is reported to the unit controller. Factory or Field Installed Disconnect Switch Accessible from outside of unit, spring loaded weatherproof cover furnished. GFI Service Outlets (2) 115v ground fault circuit interrupter (GFCI) type. INDOOR AIR QUALITY 0 Air Filters Disposable 2 inch filters furnished as standard. OPTIONS /ACCESSORIES Factory or Field Installed Healthy Climate® High Efficiency Air Filters Disposable MERV 8 or MERV 13 (Minimum Efficiency Reporting Value based on ASHRAE 52.2) efficiency 2 inch pleated filters. Healthy Climate® UVC Germicidal Lamps Helps eliminate mold and bacterial growth on the evaporator and drain pans. Improves indoor air quality and maintains efficiency of system by reducing fouling of evaporator coil. Indoor Air Quality (CO2) Sensors Monitors CO2 levels, reports to the Prodigy® Unit Controller which adjusts economizer dampers as needed. SERVICEABILITY Designed to streamline general maintenance and decrease troubleshooting time. Diagnostics Prodigy Unit Controller diagnostic scrolling text pinpoints problems, minimizing troubleshooting time. SmartWireTM System Advanced wiring connectors are keyed and color -coded to prevent miswiring. Wire coloring scheme is standardized across all models. Each connection is intuitively labeled to make troubleshooting and servicing quick and easy. Electrical Plugs Positive connection electrical plugs are used to connect common accessories or maintenance parts for easy removal or installation. Toolless, Hinged Access Panels Large access panels are hinged and have quarter -turn, latching handles for quick and easy access to maintenance areas (economizer / filter, compressor / controls/ blower / heat section). Blower Access Supply air blower parts are located near the access door for easy servicing and adjustment. Energence® Packaged Gas / Electric 3 to 6 Ton / Page 6 Thermal Expansion Valves Thermal expansion valves are located near the perimeter of the unit for easier access. Removable element head allows change out of element and bulb without removing the TXV. Coil Cleaning Independently formed condenser coils allow separation for easier cleaning. Standard Components A large number of common maintenance parts are standard throughout the entire range of sizes (3 -30 tons), reducing the need to carry a lot of different parts to the job or maintain in inventory. Compressor Compartment Compressors are located near the perimeter of the unit for easier access. Compressors are isolated from the condenser airflow allowing system operation checks to be done without changing the airflow across the outdoor coils. Service Valves (optional) Optional factory installed liquid and discharge service valves allow refrigerant to be isolated to the high side for service work on the low side of the refrigeration system. PRODIGY® CONTROL SYSTEM ® PRODIGY UNIT CONTROLLER The Prodigy Unit Controller is a microprocessor -based control board that provides flexible control of all unit functions. Prodigy Unit Controller features: Scrolling Display - Scrolls full text instead of numerical codes. Push Buttons - Simplified navigation during setup and diagnostics. Guided Setup Procedure - Insures proper installation and setup of the rooftop unit. Profile setup - Copy key setpoints between units with the same configuration greatly reducing setup time. USB Port - Easily download and transfer unit information via a USB flash drive and also interface with Lennox Unit Controller Software. Self Test Mode - Confirm proper component and system operation. Time Clock with Run -time Information Built -In Functions Include: Adjustable Blower On /Off Delay Built -in Control Parameter Defaults Compressor Time -Off Delay DDC Compatible Dirty Filter Switch Input Discharge Air Temperature Control Display /Sensor Readout Economizer Control Options - See Economizer / Outdoor Air/ Exhaust Options. Fresh Air Tempering Extensive Unit Diagnostics - Over 100 diagnostic and status messages in English. Exhaust Fan Control Modes - Fresh air damper position. Permanent Diagnostic Code Storage Field Changeable Control Setpoints - Over 200 different control setpoints. Indoor Air Quality Input - Demand Control Ventilation ready Low Ambient Controls - Cooling operation down to 0 °F. Gas Valve Time Delay Between First and Second Stage Minimum Compressor Run Time Network Capable - Can be daisy chained to other units or controls. Night Setback Mode Return Air Temperature Limit Control Safety Switch Input - Allows Controller to respond to a external safety switch trip. Service Relay Output Smoke Alarm Mode - Four choices. Staging - up to 4 heat/4 cool (zone sensor or network operation). Up to 2 heat/2 cool (standard Prodigy unit controller thermostat input). Up to 3 cool (thermostat input with additional relay). "Strike Three" Protection Gas Reheat Control - Simultaneous heating and cooling operation for controlling humidity for process air applications such as supermarkets. On Demand Dehumidification - Monitors and controls condenser hot gas reheat operation with Humiditrol® option. Thermostat Bounce Delay Warm Up Mode Delay LED Indicators PC Interface - For use with PC with optional Unit Controller software. Zone Sensor Operation - Controls zone temperature. OPTIONS / ACCESSORIES Factory or Field Installed Blower Proving Switch Monitors blower operation, shuts down unit if blower fails. Dirty Filter Switch Senses static pressure increase indicating dirty filter condition. NOTE - Prodigy Control System features shown vary with the type of rooftop unit the control is installed in. NOTE - See separate Prodigy Control System Product Specifications Bulletin for additional information. CONTROLS OPTIONS Factory or Field Installed Fresh Air Tempering Used in applications with high outside air requirements. The Controller energizes the first stage heat as needed to maintain a minimum supply air temperature for comfort, regardless of the thermostat demand. When ordered as a factory option, the sensor ships with the unit but must be field installed. Smoke Detector Photoelectric type, installed in supply air section, return air section or both sections. Available with power board and single sensor (supply or return) or power board and two sensors (supply and return). Power board located in unit control compartment. Interoperability via BACnet® or LonTalk® Protocols Communication compatible with third -party automation systems that support the BACnet Application Specific Controller device profile, LonMark® Space Comfort Controller functional profile, or LonMark Discharge Air Controller functional profile. Commercial Control Systems L Connection® Network Control System Complete building automation control system for single or multi -zone applications. Options include local interface, software for local or remote communication, and hardware for networking other control functions. See L Connection Network Control System Product Specifications Bulletin for details. Aftermarket DDC Novar® Unit Controller and options. Thermostats Control system and thermostat options. Aftermarket unit controller options. Field Installed Humidity Sensor Kit Humidity sensor required with factory installed Humiditrol® dehumidification option or Supermarket reheat field selectable option. Energence° Packaged Gas / Electric 3 to 6 Ton / Page 7 OPTIONS / ACCESSORIES 4 ECONOMIZER /OUTDOOR AIR /EXHAUST OPTIONS Factory or Field Installed Economizer Parallel gear -driven action return air and outdoor air dampers, plug -in connections to unit, nylon bearings, neoprene seals, 24 -volt, fully- modulating, spring return motor, adjustable minimum damper position. Outdood Air Hood is furnished (factory or field installation). Factory installed Economizer can be ordered with three exhaust options: 1. Barometric Relief Dampers and Exhaust Hood. 2. Power Exhaust Fan (includes Barometric Relief Dampers and Exhaust Hood). 3. No Exhaust. Field installed Economizer includes Barometric Relief Dampers with Exhaust Hood. Choice of economizer control options: 1. Differential Sensible Control Factory setting. Uses outdoor air and return air sensors that are furnished with the unit. The Prodigy Unit Controller compares outdoor air and return air and using setpoints, enables the economizer when the outdoor air temperature is below the configured setpoint and cooler than return air. NOTE - Differential Sensible Control can be configured in the field to provide Offset Differential Sensible Control or Single Sensible Control. In Offset Differential Sensible Control mode, the economizer is enabled if the temperature differential (offset) between outdoor air and return air reaches the configured setpoint. In Single Sensible Control mode, the economizer is enabled when outdoor air temperature falls below the configured setpoint. 2. Global Control The unit controller communicates with a DDC system with one global sensor (enthalpy or sensible) to determine whether outside air is suitable for free cooling on all units connected to the control system. Sensor must be field provided. 3. Single Enthalpy Control Outdoor air enthalpy sensor enables economizer if the outdoor enthalpy is less than the setpoint of the board. 4. Differential Enthalpy Control Two enthalpy sensors allow the economizer control to select between outdoor air or return air, whichever has lower enthalpy. Outdoor Air Damper - Downflow or Horizontal Linked mechanical dampers, 0 to 25% (fixed) outdoor air adjustable, installs in unit, outdoor air hood must be ordered separately. Automatic model features fully modulating spring return damper motor with plug -in connection. Manual model features a slide damper. Maximum mixed air temperature in cooling mode: 100 °F. Barometric Relief Dampers and Exhaust Hood Barometric Relief Dampers allow relief of excess air, aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle, bird screen furnished. Hood is furnished. Required when Economizer is factory installed with field installed Power Exhaust Fan option. Power Exhaust Fan Installs internal to unit for downflow applications with economizer option. Provides exhaust air pressure relief. Interlocked to run when supply air blower is operating, fan runs when outdoor air dampers are 50% open (adjustable), motor is overload protected. Fan is 16 in. diameter with 4 fan blades (E1 PWRE10A) or 20 in. diameter with 5 blades (El PWRE1 ON). Both include a 1/3 hp motor. Energence° Packaged Gas / Electric 3 to 6 Ton / Page 8 NOTE - If Power Exhaust is field installed with a factory installed Economizer, the Economizer must be ordered with No Exhaust option and Barometric Relief Dampers and Exhaust Hood must also be ordered separately for field installation. Field Installed Horizontal Economizer Conversion Kit Insulated panel covers the bottom return air opening on the unit base to convert downflow economizer to horizontal air flow. ROOF CURBS (DOWNFLOW) Nailer strip furnished, mates to unit, US National Roofing Contractors Approved, shipped knocked down. Clip Curbs - Uses interlocking tabs to fasten corners together. No tools required. Hinged Curbs - Curb comers fasten together with furnished hinge pins. Standard Curbs - Curb comers fasten together with furnished hardware. Transition Curbs - Curbs are regionally sourced. Dimensions will vary based upon the source. Contact your Lennox sales representative for a detailed cut sheet with applicable dimensions. See Options /Accessories table for available curbs. CEILING DIFFUSERS Ceiling Diffusers (Flush or Step -Down) Aluminum grilles, large center grille, insulated diffuser box with flanges, hanging rings furnished, interior transition (even air flow), internally sealed (prevents recirculation), adapts to T -bar ceiling grids or plaster ceilings. Transitions (Supply and Return) Used with diffusers, installs in roof curb, galvanized steel construction, flanges furnished for duct connection to diffusers, fully insulated. OPTIONS / ACCESSORIES HUMIDITROL DEHUMIDIFICATION® SYSTEM Factory installed option designed to control humidity. Provides dehumidification on demand using ASHRAE 90.1 recommended method for comfort conditioning humidity control. Unit comes equipped with one row reheat coil, solenoid valve and humidity controller. In addition to a thermostat or room sensor used for conventional operation, a humidity sensor is required and must be located in the occupied space. Remote Mounted Humidity Sensor Kit is required for field installation. The humidity sensor provides input to the Unit Controller which is used to control activation of the dehumidification operation. Reheat controls are located in the compressor control section of the unit for easy access. Benefits Improves indoor air quality. Helps prevents damage due to high humidity levels. Improves comfort levels by reducing space humidity levels. OPERATION No Dehumidification Demand The unit will operate conventionally whenever there is a demand for cooling or heating and no dehumidification demand. Free cooling is only permitted when there is no demand for dehumidification. Dehumidification Demand Only The Unit Controller is factory set at 60% relative humidity setpoint and can be adjusted at the Unit Controller or with optional Unit Controller Software. For L Connection® Network Control Panel (NCP) applications, the humidity setpoint can be adjusted at the NCP. Reheat operation will initiate on a dehumidification demand and does not require a cooling demand. The unit will operate in the dehumidification mode until the relative humidity of the conditioned space is below the setpoint. The reheat coil is sized to provide 68 °F to 75 °F supply air during reheat operation. This reduces sensible cooling capacity and extends compressor run time to control humidity when the cooling load is low. TYPICAL HUMIDITROL DEHUMIDIFICATION SCHEMATIC RETURN AIR OUTDOOR AIR COMPRESSOR CHECK VALVE EXPANSION ALVE SOLENOID VALVE A solenoid valve diverts hot gas from the compressor to the reheat coil. The cooled and dehumidified air from the evaporator is reheated as it passes through the reheat coil. The de- superheated and partially condensed refrigerant continues to the outdoor condenser coil where condensing is completed. The unit will continue to operate in this mode until the dehumidification demand is satisfied. See Sequence of Operation for additional information. Dehumidification and Cooling Demand (Thermostat/Room Sensor Application) Two -stage compressor models (036, 048, 060) If both a dehumidification and a Y1 cooling demand occur, the system will operate in the full cooling mode at first stage indoor air flow. If a Y2 cooling demand occurs along with a dehumidification demand, the system operates in full cooling mode at full cooling airflow until the Y2 cooling demand is satisfied. Then the system will revert to the dehumidification mode if a dehumidification mode demand is present. Single speed compressor model (072H) If both a dehumidification and a cooling demand occur, the system will operate in cooling until the cooling demand is satisfied. Then the system will energize the dehumidification mode. ACCESSORIES Humidity Sensor Kit, Remote Mounted Humidity sensor required with factory installed Humiditrol® Option or Supermarket reheat field selectable option. Energence Packaged Gas / Electric 3 to 6 Ton / Page 9 SUNSOURCE® COMMERCIAL ENERGY SYSTEM uw m.a :taw! .ull_. - rrppri '(_( WI�lt liM l' 111, 10�`✓''�Y SYSTEM OVERVIEW All Energence®3 through 6 ton commercial rooftop units are upgradable to the SunSource® Commercial Energy System. Solar energy is first used to meet building cooling/ heating demands. When the cooling and heating system is not operating, the system powers lighting, appliances and other electronic devices in the building. And in some locations, any surplus power is sent back to the utility company for a possible credit (check with your local utility company for availability). The SunSource® Commercial Energy System consists of the following components: 1. Energence® 3 to 6 ton commercial rooftop units with factory installed Solar Power Entry Option (circuit protection for solar power and line voltage wiring). 2. Solar Modules (up to 21 modules with three -phase power, up to 15 modules with single -phase power) may be used to vary the amount of electricity generated). 3. Envoy Communications Gateway that monitors energy usage. 4. Enphase Enlighten TM Performance Monitoring Website Wiring from the roof mounted solar modules is routed to the rooftop unit. NOTE - Refer to separate Product Specifications Bulletin for the SunSource® Commercial Energy System for more detailed information. See section Solar - Kits/Accessories. Energence° Packaged Gas / Electric 3 to 6 Ton / Page 10 Also refer to SunSource® Commercial Energy System Applications and Design Guidelines Manual (Corp. 1104 -L4) for complete information on designing, sizing and installing a complete system. APPROVALS SunSource® Commercial Energy System is certified by ETL to conform to UL 1995 and NEC 690 standards. The SunSource® Energy System for Commercial Rooftop Units meets the requirements for federal tax credits listed under the U.S. Emergency Economic Stabilization Act of 2008, covering 30% of the cost of the solar modules, including installation. BASIC SYSTEM REQUIREMENTS Sufficient south- facing open roof space. Broadband Internet connection. 208/240 single or three - phase, 460V three - phase, 575V three - phase. Grid Interconnection Agreement. SOLAR POWER ENTRY OPTION A factory installed power entry option is available for Energence® rooftop units that provides a connection point for SunSource® solar modules. The option provides circuit protection (fuses) for the solar connection and rooftop unit components. An extemally accessible disconnect (non- fused) is also included to shutdown the system for service. Field wiring connections are made directly to the disconnect for the utility connection and to a pigtail for easy solar connection. Local codes may require a field provided solar disconnect and/or a field provided fused HVAC disconnect. SUNSOURCE® COMMERCIAL ENERGY SYSTEM SOLAR MODULES Converts solar energy into electricity. Built -in racking hardware, wiring, grounding and microinverters. Microinverters produce AC power synchronized to the utility grid. Modules operate independently from each other allowing modules that are not shaded or dirty to operate with optimum performance. Racking system is built -in to the module frame. Painted flat black frame. Solar modules are CSA listed for the US and Canada to UL Standard 1703 and meet National and Canadian Electrical Code requirements. FLAT ROOF MOUNTING SYSTEM Flat Roof Mouting system consists of: • Ballast Pans (ballast and non - ballast) • Support Brackets with fastening screws • Solar Splices with Lockwashers • Left-hand and Right -hand End Bolts with Lockwashers • Ground Lug Connector(s) NOTE - Concrete pavers (15 lbs., 2 x 8 x 16 in.) are not furnished and must be field provided. Pavers are installed in the Ballast Pans to meet system weight and engineering requirements. INSTALLATION KITS AND TOOLS AC System Kit (Required - One per each rooftop unit) Kit includes interconnection cable required to adapt microinverter cable to field wiring. Includes plug to microinverter and pigtails for field wiring. Also includes the end cap to place on the last microinverter connection in the row. One kit required per rooftop unit. Kit contains 6 ft. AC interconnection cable and end cap. AC 6 Foot Extension Cable Six foot extension cable for Qsconnecting one row of modules to the next if they are further than the standard interconnection cable can reach (second row above or below, etc.). Only required for multiple rows. Professional Installer Tool Kit Installer tools to aid in installation. Includes driver to tighten splices with ratchet from opposite side of module (in place of wrench) and step block •*"....�` to support module until splices and \ mounting points are installed. Includes (2) Splice Drivers and (2) Step Blocks Solar Module Splices Required to join modules together in a row and provide a grounding path. Two splices per module interface are required. (Left-hand and Right -hand threaded bolts are used at the ends of a row). ELECTRICAL COMPONENTS Transformer (For 230V and 460V -3ph Rooftop Units) Steps up the output voltage of the microinverters to connect directly to the rooftop unit. NOTE - 575V is not available and must be field provided. Energence° Packaged Gas / Electric 3 to 6 Ton / Page 11 'SUNSOURCE® COMMERCIAL ENERGY SYSTEM SYSTEM MONITORING Envoy Communications Gateway (Communications Booster Furnished) The Envoy Communications Gateway monitors microinverter (on solar modules) performance and can be connected to a broadband internet connection to send data to the Enphase Enlighten TM web site for online monitoring. The Envoy Communications Gateway is not required, but must be used if system performance monitoring is desired. Limited system monitoring is also available locally with the Envoy Communications Gateway and a computer if no Internet connection is available. Various Event Messages are also available when monitoring the system via a computer locally. Contents - (1) Envoy Communications Gateway, (1) Communications Booster, (1) 6 ft. power cord, (1) 10 ft. Ethernet cable. CSA (US /C) listed. The Envoy Communications Gateway includes a Communications Booster which may or may not be needed depending upon how far the Envoy is away from the solar modules. Communications Booster Ethernet bridge signal booster for the Envoy Communications Gateway. Booster is only needed if the communications gateway is installed and signal is not strong enough in the installed location. Allows the unit to be plugged into an outlet closer to the distribution panel, yet still plug into the broadband router. Line Communications Filter Envoy Communications Gateway mounted in a Mix weatherproof NEMA4 enclosure. For outdoor installations, installations with transformers, or when multiple communications modules are used on one building. Contains the Envoy Communications Gateway and terminal blocks for easy power hookup from the microinverter branch circuits distribution to the electrical meter or distribution panel. A filter removes any electrical interference from other devices or multiple Envoy Communication Gateways in the same building. Unit is UL listed for the US and Canada and meet National Electrical Code requirements. Energence® Packaged Gas / Electric 3 to 6 Ton / Page 12 Enphase Enlighten TM Performance Monitoring Website Powered by the Envoy -- -- as " Communications Gateway, -_ r.. 6.,.1a1 the Enphase Enlighten TM Performance Monitoring website allows the user to keep track of building energy usage and see environmental benefits in real time. See demos, view reference installations and other additional information at: http : / /enlighten.enphaseenergy.com/ SYSTEM ORDERING • Specify the number of Solar Modules needed and number of rows required along with the associated order no. The correct number of components (Solar Splices, AC Extension Cables, Ballast Pans, Pans, Support Brackets and Fastening Hardware) for the Flat Roof Mounting System will be furnished with the solar modules and shipped as a kit. • Energence® 3 to 6 ton packaged rooftop unit must be ordered with the factory installed Solar Power Entry Option. • Envoy Communications Gateway or Line Communications Filter must be ordered separately. • Transformer must be ordered separately. Contact your nearest Lennox Sales Representative for ordering information. OPTIONS / ACCESSORIES Item Model Catalog Number Number Unit Model No 036 048 060 072 COOLING SYSTEM Condensate Drain Trap PVC - C1TRAP2OAD2 Copper - C1TRAP1OAD2 76W26 76W27 OX OX OX OX OX OX OX OX Drain Pan Overflow Switch EISNSR71AD1 68W88 OX OX OX OX Efficiency Standard High Factory Factory 0 0 0 0 0 0 0 0 Service valves (not for Humiditrol equipped units) 0 Factory 0 0 0 0 HEATING SYSTEM Bottom Gas Piping Kit T1GPKTO1AN1 19W50 OX OX OX OX Combustion Air Intake Extensions T1 EXTN10AN1 19W51 X X X X Gas Heat Input Standard One -Stage - 65 kBtuh input Medium One -Stage -105 kBtuh input Medium Two Stage - 73.5/105 kBtuh input High Two -Stage - 105/150 kBtuh input High One -Stage - 150 kBtuh input Factory Factory Factory Factory Factory 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Low Temperature Vestibule Heater 208/230V-1 or 3ph - E1 LTVH10A -1Y 460V -3ph - E1LTVH10A -1G 575V -3ph - E1LTVH10A -1J 54W23 54W24 54W25 OX OX OX OX OX OX OX OX OX OX OX OX LPG /Propane Conversion Kits For one -stage models - C1 PROP10AP1 For two -stage models - C1 PROP20AP1 53W69 53W70 X X X X X X X Stainless Steel Heat Exchanger Factory 0 0 0 0 Vertical Vent Extension C1EXTN2OFF1 31W62 X X X X BLOWER - SUPPLY AIR Motors Drive Kits See Blower Data Tables for selection Direct Drive - 0.50 hp Factory Direct Drive - 0.75 hp Factory Direct Drive - 1 hp Factory Belt Drive - 0.75 hp (2 Speed) Factory Belt Drive -1 hp (2 Speed) Factory Belt Drive - 2 hp (2 Speed) Factory Belt Drive - 1 hp Standard Efficiency Factory Belt Drive - 2 hp Standard Efficiency Factory Belt Drive - 1 hp High Efficiency Factory Belt Drive - 2 hp High Efficiency Factory Kit A01 - Ti DRKT001 -1 - 673 -1010 rpm Factory Kit A02 - T1 DRKT002 -1 - 745 -1117 rpm Factory Kit A03 - T1 DRKT003 -1 - 833 -1250 rpm Factory Kit A05 - Ti DRKT005 -1 - 897 -1346 rpm Factory Kit A06 - T1 DRKT006 -1 -1071 -1429 rpm Factory Kit A07 - T1 DRKT007 -1 - 1212 -1548 rpm Factory Kit AA01 - T1 DRKT001AP1 - 522 -784 rpm Factory Kit AA02 - T1 DRKT002AP1 - 632 -875 rpm Factory Kit AA03 - T1 DRKT003AP1 - 798 -1105 rpm Factory Blower Belt Auto - Tensioner Factory 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O CABINET Coil Guards Hail Guards Corrosion Protection (indoor coil / outdoor coil) T1 GARD20A -1 17W87 T1GARD2ON-1 17W88 T1 GARD 10A -1 17W89 T1 GARD1 ON -1 17W90 Factory X X X X X X X 0 0 0 NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Fileld Installed 0 = Configure To Order (Factory Installed) X = Field Installed Energence° Packaged Gas /Electric 3 to 6 Ton / Page 13 OPTIONS / ACCESSORIES Item Model Catalog Number Number Unit Model No 036 048 060 072 CONTROLS Blower Proving Switch C1SNSR35FF1 53W65 OX OX OX OX Commercial Controls CPC Einstein Integration Prodigy° Control System - BACnet° Module - COCTRL60AE1L Prodigy° Control System - LonTalk° Module - COCTRL65FF1 Novar° 5021 - EOCTRL30A1 Novar° LSE L Connection° Building Automation System Factory 59W51 54W27 64W72 Factory --- 0 0 0 0 OX OX OX OX OX OX OX OX OX OX OX OX 0 0 0 0 X X X X Dirty Filter Switch EISNSR55AP1 53W66 OX OX OX OX Fresh Air Tempering C1SNSR75AD1 58W63 OX OX OX OX Smoke Detector - Supply or Retum (Power board and one sensor) C1SNSR44AP1 53W78 OX OX OX OX Smoke Detector - Supply and Return (Power board and two sensors) C1SNSR43AP1 53W79 OX OX OX OX ELECTRICAL Voltage 60 hz 208/230V - 1 phase 208/230V - 3 phase 460V - 3 phase 575V - 3 phase Factory Factory Factory Factory ' 0 ' 0 1 0 Economizer - With Power Exhaust Fan and Barometric Relief Dampers with Exhaust Hood 0 0 0 0 0 0 0 0 0 0 0 0 HACR Circuit Breakers X Factory 0 0 0 0 Disconnect Switch 80 amp - T1 DISC080AH1 80 amp - Ti DISCO8ONH1 20W23 20W26 OX OX X X X OX OX GFI Service Outlets LTAGFIKIO /15 74M70 OX OX OX OX PhaseNoltage Detection - 3 Phase Models Only Factory 0 0 0 0 ECONOMIZER Economizer With Outdoor Air Hood (Sensible Control Economizer - With Barometric Relief Dampers and Exhaust Hood Factory 0 0 0 0 Economizer - With Power Exhaust Fan and Barometric Relief Dampers with Exhaust Hood Factory 0 0 0 0 Economizer - No Exhaust Option Factory 0 0 0 0 Economizer - With Barometric Relief Damper with Hood El ECON30A -1- ElECON3OAT1- 53W33 53W36 X X Sensor Field Provided Factory 0 0 X X Horizontal Economizer Conversion Kit T1 HECKOOAN1 17W45 X X X X Economizer Controls Differential Enthalpy Order 2 - C1SNSR64FF1 53W64 OX OX OX OX Sensible Control Sensor is Furnished Factory 0 0 0 0 Single Enthalpy C1SNSR64FF1 53W64 OX OX OX OX Global Control Sensor Field Provided Factory 0 0 0 0 OUTDOOR AIR Outdoor Air Dampers Damper Section - Manual, Includes Outdoor Air Hood Damper Section - Motorized, Includes Outdoor Air Hood CIDAMP11A -1- 53W34 C1DAMP11AT1- 53W37 E1DAMP21A -1- 53W35 EIDAMP21AT1- 53W38 OX OX OX OX OX OX OX OX POWER EXHAUST FAN Standard Static Note - Includes Barometric Relief Dampers and Exhaust Hood when factory installed. Order Barometric Reilef Dampers and Exhaust Hood below when field installed. 2 BAROMETRIC RELIEF Barometric Relief Dampers with Exhaust Hood 208/230V -1 or 3ph 460V-3ph - 575V- 3ph 208/230V-1 or 3ph - 460V- 3ph - 575V- 3ph - C1 PWRE10A -1 P C1 PWRE10A -1G - C1 PWRE10A -1J C1 PWRE1 OAT1 P C1 PWRE1OAT1G - CIPWRE1OAT1J 79W87 79W88 79W89 79W90 79W91 79W92 OX OX OX OX OX OX OX OX OX OX OX OX C1DAMP50A -1- 74W38 C1DAMP5OAT1- 74W39 X X X X ' 20 &230 -1 ph not available on belt drive units. 2 Required when Economizer is factory installed (no exhaust option) with field installed Power Exhaust Fan option. NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Fiteld Installed O = Configure To Order (Factory Installed) X = Field Installed Energence° Packaged Gas / Electric 3 to 6 Ton / Page 14 OPTIONS / ACCESSORIES Item Model Catalog Number Number Unit Model No 036 048 060 072 HUMIDITROL® CONDENSER REHEAT OPTION Humiditrol Humidity Sensor Kit, Remote mounted (required) INDOOR AIR QUALITY Air Filters Healthy Climate® High Efficiency Air Filters Order 4 per unit Factory COSNSR31AE -1 17M50 0 0 0 0 X X X X Replaceable Media Filter With Metal Mesh Frame (includes non - pleated filter media) Indoor Air Quality (CO,) Sensors Sensor - Wall- mount, off -white plastic cover with LCD display Sensor - Wall- mount, off-white plastic cover, no display Sensor - Black plastic case with LCD display, rated for plenum mounting Sensor - Wall-mount, black plastic case, no display, rated for plenum mounting CO2 Sensor Duct Mounting Kit - for downflow applications Aspiration Box - for duct mounting non - plenum rated CO2 sensors (87N53 or 77N39) UVC Germicidal Lamps ' Healthy Climate° UVC Light Kit (208 /230v -1ph) ROOF CURBS - DOWNFLOW Clip Curb MERV8(16x20x2)-CIFLTRI5A-1- MERV 13 (16 x 20 x 2) - T1 FLTR40A -1- MERV 8 (20 x 20 x 2) - C1 FLTR15D -1- MERV 13 (20 x 20 x 2) - C1 FLTR40D -1- 16 x 20 x 2 (Order 4) - K1 FLTR30A -1 20 x 20 x 2 (Order 4) - K1 FLTR30A -2 54W20 52W37 54W21 52W39 39W09 44N60 OX OX OX OX OX OX OX OX X X X X COSNSR5OAE1L COSNSR52AE1L COSNSR51AE1L COMISC19AE1 COMISC19AE1- COMI SC 16AE 1- 77N39 87N53 87N52 87N54 85L43 90N43 X X X X X X X X X X X X C1UVCL10AN1- 50W90 OX OX OX OX 8 in. height 14 in. height 18 in. height 24 in. height Hinged T1CURB23AN1 16W93 T1 CURB20AN1 16W94 T1CURB21AN1 16W95 T1CURB22AN1 16W96 X X X X X X X X X X X X X X X X 8 in. height 18 in. height 24 in. height Standard T1CURB30AN1 17W46 T1CURB32AN1 17W47 T1CURB33AN1 17W48 X X X X X X X X X X X X 14 in. height Adjustable Pitched Curb 14 in. height Transition Curb Matches Energence° 036 -072 Units to existing L Series° Curbs CEILING DIFFUSERS Step -Down - Order one T1CURB10AN1 13W27 1 X X X X CICURB55AT1 43W27 1 X X X X E1CURB6OA -1 20W06 1 X X X X Flush - Order one Transitions (Supply and Return) - Order one RTD9 -65 -R RTD11 -95 (Canada Only) RTD11 -95S FD9 -65 -R FD11 -95 (Canada Only) FD11 -95S TITRANIOAN1 TITRAN2ON -1 27G87 29G04 13K61 27G86 29G08 13K56 17W53 17W54 X X X X X X X X X X X X X SUNSOURCE ®COMMERCIAL ENERGY SYSTEM Solar Power Entry with Disconnect Factory 0 0 0 0 Envoy Communications Gateway with Communications Booster (internal) Y4263 X X X X Line Communication Filter (extemal) COMSD X X X X 2Transformer E1TRFM1OAD1Y (230 VAC Delta) E1TRFMIOADIG (460 VAC Delta) E1TRFM15AD1G (460 VAC Wye) 80W91 80W92 80W93 X X X X X X X X X X X X ' Lamps operate on 110.230V single -phase power supply. Step -down transformer may be ordered separately for 460V and 575V units. Altemately, 110V power supply may be used to directly power the UVC ballast(s). 2 575V transformer is not available and must be field provided. NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Fileld Installed 0 = Configure To Order (Factory Installed) X = Field Installed Energence° Packaged Gas / Electric 3 to 6 Ton / Page 15 SPECIFICATIONS - DIRECT DRIVE General Data Nominal Tonnage Model Number Efficiency Type Blower Type 3 Ton 4 Ton 5 Ton LGH036H4E LGH048H4E LGH060H4E High High High Multi -Speed Direct Drive Multi -Speed Direct Drive Multi -Speed Direct Drive Cooling Gross Cooling Capacity - Btuh Performance 1 Net Cooling Capacity - Btuh AHRI Rated Air Flow - cfm Total Unit Power - kW 1 SEER ( Btuh/Watt) - 208/230V 1 -3ph ' SEER (Btuh/Watt) - 460V 3ph, 575V 3ph ' EER ( Btuh/Watt) Refrigerant Type Refrigerant Charge Fumished Refrigerant Charge Furnished with Humiditrol® Option 35,800 50,100 61,600 35,200 49,000 60,000 1200 1600 1750 2.8 3.8 . 4.7 18.0 17.6 17.1 17.0 17.0 17.0 12.7 12.8 12.7 R-410A R-410A R-410A 9 lbs. 1 oz. 11 lbs. 5 oz. 15 lbs. 8 oz. 9 lbs. 12 oz. 12 lbs. 7 oz. 17 lbs. 8 oz. Gas Heating Options Available - See page 18 Standard (1 stage) or Medium (1 or 2 stage) Standard (1 stage), Medium (1 or 2 Stage) or High (1 or 2 Stage) Standard (1 stage), Medium (1 or 2 Stage) or High (1 or 2 Stage) Compressor Type (number) Scroll (1) Scroll (1) Scroll (1) Outdoor Coils Net face area (total) - sq. ft. Tube diameter - in. Number of rows Fins per inch 15.60 15.60 19.30 3/8 3/8 3/8 1.5 2 2 20 20 20 Outdoor Coil Motor- (No.) horsepower Fans Motor rpm Total Motor Input - watts Diameter - (No.) in. Number of blades Total air volume - cfm (1) 1/3 (ECM) (1) 1/3 (ECM) (1) 1/3 (ECM) 715- 810 645 -810 930 -1100 112 -160 89 -165 230 -350 (1) 24 (1) 24 (1) 24 3 3 3 3400 -3795 2910 -3675 4315 -4980 Indoor Net face area (total) - sq. ft. Coils Tube diameter - in. Number of rows Fins per inch Drain connection (Number) and size - in. Expansion device type 7.78 7.78 9.72 3/8 3/8 3/8 3 4 4 14 14 14 (1) 1 NPT (1) 1 NPT (1) 1 NPT Balance port TXV, removable head 2 Indoor Nominal motor HP Blower Blower wheel nominal diameter x width - in. 0.50 (ECM) 0.75 (ECM) 1 (ECM) (1) 10 X 10 (1) 10 X 10 (1) 11 X 10 Filters Type of filter Number and size - in. disposable (4) 16 X 20 X 2 (4) 20 x 20 x 2 Electrical characteristics 208/230V - 60 hz - 1 phase 208/230V, 460V, or 575V - 60 hz -3 phase NOTE - Net capacity indudes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. ' AHRI Certified to AHRI Standard 210/240: 95 °F outdoor air temperature and 80 °F db167 °F wb entering evaporator air; minimum external duct static pressure. 2 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. Energencee Packaged Gas / Electric 3 to 6 Ton / Page 16 SPECIFICATIONS - BELT DRIVE General Data Nominal Tonnage Model Number Efficiency Type Blower Type 3 Ton 4 Ton 5 Ton 6 Ton LGH036S4T LGH048S4T LGH060S4T LGH072H4B Standard Standard Standard High Two Speed Belt Drive Two Speed Belt Drive Two Speed Belt Drive Single Speed Belt Drive Cooling Gross Cooling Capacity - Btuh Performance Net Cooling Capacity - Btuh AHRI Rated Air Flow -cfm Total Unit Power - kW SEER (Btuh/Watt) EER(Btuh/Watt) IEER (Btuh/Watt) Refrigerant Type Refrigerant Charge Furnished Refrigerant Charge Furnished with Humiditrol® Option 35,800 50,100 61,600 73,500 ' 34,800 ' 49,000 ' 60,000 2 72,000 1200 1600 1750 1920 3.0 4.1 4.8 6.0 ' 15.0 ' 15.0 ' 15.5 - - - '11.6 '12.5 '12.5 212.0 - - - - - - - - - 213.5 R-410A R-410A R-410A R-410A 9 lbs. 1 oz. 11 lbs. 5 oz. 15 lbs. 8 oz. 16 lbs. 5 oz. 9 lbs. 12 oz. 12 lbs. 7 oz. 17 lbs. 8 oz. 16 lbs. 5 oz. Gas Heating Options Available - See page 18 Standard (1 stage) or Medium (1 or 2 stage) Standard (1 stage), Medium (1 or 2 Stage) or High (1 or 2 Stage) Standard (1 stage), Medium (1 or 2 Stage) or High (1 or 2 Stage) Standard (1 stage), Medium (1 or 2 Stage) or High (1 or 2 Stage) Compressor Type (number) Scroll (1) Scroll (1) Scroll (1) Scroll (1) Outdoor Coils Net face area (total) - sq. ft. Tube diameter - in. Number of rows Fins per inch 15.60 15.60 19.30 19.30 3/8 3/8 3/8 3/8 1.5 2 2 2 20 20 20 20 Outdoor Coil Motor- (No.) horsepower Fans Motor rpm Total Motor Input - watts Diameter -(No.) in. Number of blades Total air volume - cfm (1) 1/6 (PSC) (1) 1/4 (PSC) (1) 1/3 (PSC) (1) 1/3 (PSC) 825 825 1075 1075 168 230 410 410 (1) 24 (1) 24 (1) 24 (1) 24 3 3 3 3 3,000 3,300 4,800 4,800 Indoor Net face area (total) - sq. ft. Coils Tube diameter - in. Number of rows Fins per inch Drain connection (Number) and size - in. Expansion device type 7.78 7.78 9.72 9.72 3/8 3/8 3/8 3/8 3 4 4 4 14 14 14 14 (1) 1 NPT (1) 1 NPT (1) 1 NPT (1) 1 NPT Balance port TXV, removable head 'Indoor No. of Speeds 2 2 2 1 Blower Nominal motor HP Low static and Drive High static 0.75 0.75 1 1 1 2 2 2 Selection Maximum usable motor output Low static (US Only) Hghstatic 0.86 0.86 1.15 1.15 1.15 2.3 2.3 2.30 Motor - Drive kit number A01 low 449-673 high 673 -1010 A05 low 598 -897 high 897 -1346 A02 low 497 -673 high 745 -1117 A06 low 714 -953 high 1071 -1429 A03 low 555 -833 high 833 -1250 A07 low 808 -1032 high 1212-1548 AA01 522 - 784 rpm AA02 632 - 875 rpm AA03 798 -1105 rpm Blower wheel nominal diameter x width - in. (1) 10 X 10 (1) 10 X 10 (1) 10 X 10 (1) 15 X 9 Filters Type of filter disposable Number and size - in. (4) 16 X 20 X 2 (4) 20 X 20 X 2 Electrical characteristics 208/230V, 460V, or 575V - 60 hz -3 phase NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. "AHRI Certified to AHRI Standard' 210/240 or 340/360: 95 °F outdoor air temperature and 80 °F db/67 °F wb entering evaporator air; minimum external duct static pressure. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors fumished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. Energence• Packaged Gas / Electric 3 to 6 Ton / Page 17 SPECIFICATIONS - GAS HEAT Model No. LGH036, LGH048, LGH060 LGH036, LGH048, LGH060 LGH072 LGH036, LGH048, LGH060 LGH072 LGH048, LGH060 LGH072 LGH048, LGH060 LGH072 Heat Input Type Standard (1 Stage) Medium (1 Stage) Medium (2 Stage) High (1 Stage) High (2 Stage) Input 1st Stage Btuh 2nd Stage 65,000 105,000 73,500 150,000 105,000 - - - - - - 105,000 - - - 150000 Output 1st Stage Btuh 2nd Stage 52,000 84,000 59,000 120,000 85,500 - - - - - - 84,000 - - - 120,000 Temperature 1st stage Rise 2nd Stage 20 - 50 25 - 70 20 - 50 15 - 55 10 - 40 40 - 85 30 - 60 25 - 65 20 - 50 - - - - - - - - - 25 -70 20 -50 - - - - - - 40 -85 30 -60 1AFUE 80 80 80 80 80 80 80 80 80 Thermal 1st Stage Efficiency 2nd Stage 80 80 80 80 80 80 80 81.5 81.5 - - - - - - - - - 80 80 - - - - - - 80 80 Gas Supply Connections 1/2 in. NPT Rec. Gas Supply Pressure - Nat./ LPG 7 in.w.g. / 11 in.w.g. Annual Fuel Utilization Efficiency based on U.S. DOE test procedures and FTC labeling regulations. HIGH ALTITUDE DERATE NOTE - Units may be installed at altitudes up to 2000 ft. above sea level without any modifications. At altitudes above 2000 ft. units must be derated to match information in the table shown. At altitudes above 4500 ft. unit must be derated 2% for each 1000 ft. above sea level. NOTE - This is the only permissible derate for these units. Heat Input Type Altitude Feet Gas Manifold Pressure in. w.g. Natural Gas LPG/ Propane Input Rate (Btuh) Standard (1 stage) 2001 - 4500 3.0 Medium (1 stage) 2001 - 4500 3.0 Medium (2 stage) 2001-4500 3.0/1.7 High (1 stage) 2001 - 4500 3.0 High (2 stage) 2001 - 4500 3.0/1.7 9.0 9.0 9.0/5.1 9.0 9.0/5.1 60,000 97,000 97,000 / 73,500 138,000 138,000/ 105,000 Energence® Packaged Gas /Electric 3 to 6 Ton / Page 18 SEQUENCE OF OPERATION Objective: Outline the unit functions as a result of room thermostat or zone sensor demands. Given: When economizer is present, it will function as initial part of the unit cooling system. When not present, unit will function as if outdoor ambient is high and sensed as not suitable. JAR CT DRIVE AND BELT DRIVE SYSTEM OPERATION (3 THROUGH 5 TONSI: Note: Direct drive units feature ECM condenser fans that are staged to match the compressor's capacity. When the compressor is operating at first stage, the condenser fan is operating at low speed. The condenser fan switches to high speed when the compressor switches to second stage to match operation. Modulating Outdoor Air Damper: Damper minimum positions #1 and 2 are adjusted during unit setup to provide minimum fresh air requirements at the indicated supply fan speeds perASHRAE 62.1. • Supply fan is off and the outdoor air damper is closed • Supply fan is on low speed and the outdoor air damper is at minimum position 1 • Supply fan is on high speed and the outdoor air damper is at minimum position 2 ' Unit Features an Economizer and Outdoor Air is Suitable Cooling - Thermostat or Zone Sensor Mode (Up to 3 stages Y1, Y2, Y3) Y1 demand: 1st: Compressor is off, supply fan is on low speed, economizer modulates (minimum to maximum open position) to maintain 55 °F supply air temperature (default unit controller setting) 2nd: After 5 minutes (default unit controller setting), supply fan switches to high speed. Economizer continues modulating with supply fan on high speed to maintain 55 °F supply air temperature Y2 demand: 1st: Compressor is off, supply fan is on high speed, and economizer modulates to maintain 55 °F supply air temperature 2nd: Economizer opens to maximum. If economizer stays at maximum open for 3 minutes (default unit controller setting) compressor is energized and operates at first stage while supply fan stays on high speed 1 Outdoor air suitability is determined by the energy state of outdoor ambient (enthalpy or sensible) and its ability to achieve the desired free cooling effects. Outdoor air suitability can also be determined by a third party controller and provided to the RTU via a network connection. Y3 demand: 1st: Economizer is at maximum open and compressor operates at first stage. If economizer stays at maximum open for 3 minutes (default unit controller setting) compressor switches to second stage operation while supply fan stays on high speed Unit Does not Feature an Economizer (or Outdoor Air Is Not Suitable) Cooling - Thermostat or Zone Sensor (Up to 2 stages Y1, Y2) Y1 demand: 1st: Compressor operates at first stage and supply fan operates at low speed Y2 demand: 1st: Compressor operates at second stage and supply fan operates at high speed (Continued on Next Page) Energence• Packaged Gas / Electric 3 to 6 Ton / Page 19 SEQUENCE OF OPERATION DIRECT DRIVE AND BELT DRIVE SYSTEM OPERATION (3 THROUGH 5 TONS1 (Continued): Dehumidification Mode (economizer free cooling is locked out): Unit features the Humiditrol® dehumidification system No Y1, Y2 demand but a call for dehumidification: 1st: Compressor operates at second stage, supply fan operates at low speed, and the reheat valve is energized Y1 demand: 1st: Compressor operates at second stage, outdoor fan operates at high speed, supply fan oper- ates at low speed and the reheat valve is de- energized Y2 demand: 1st: Compressor operates at second stage, supply fan operates at high speed, and the reheat valve is de- energized Heating mode: Thermostat or Zone Sensor (Up to 2 stages WI, W2) W1 demand: 1st: Gas valve is open (stage 1 on units with 2 stage gas valve) and the supply fan operates at high speed W2 demand: 1st: Gas valve is open (stage 2 on units with 2 stage gas valve) and the supply fan operates at high speed Energence° Packaged Gas /Electric 3 to 6 Ton / Page 20 SEQUENCE OF OPERATION SINGLE STAGE UNIT OPERATION (6 TONI Modulating Outdoor Air Damper: Damper minimum positions are adjusted during unit setup to provide minimum fresh air requirements at the indicated supply fan speeds perASHRAE 62.1. 1) Supply fan is off and the outdoor air damper is closed 2) Supply fan is on and the outdoor air damper is at minimum position ' Unit Features an Economizer and Outdoor Air is Suitable Cooling - Thermostat or Zone Sensor (Up to 2 stages Y1, Y2). Y1 demand: 1st: Compressor is off, supply fan is on, economizer modulates (minimum to maximum open posi- tion) to maintain 55 °F supply air temperature (default unit controller setting) Y2 demand: 1st: Economizer goes to maximum open position and if the damper stays open for three minutes (default unit controller setting) the compressor is energized. Unit Does Not Feature an Economizer (or outdoor air is not suitable) Cooling - Thermostat or Zone Sensor (Up to 1 stage Y1). Y1 demand: 1st: Compressor is operating and supply fan is on. Dehumidification Mode (economizer free cooling is locked out): Unit features the Humiditrol® dehumidification system No Y1 demand but a call for dehumidification: 1s': Compressor is operating, supply fan is on, and the reheat valve is energized. Y1 demand: 1st: Compressor is operating, supply fan is on, and the reheat valve is de- energized. Y2 demand: 1st: Compressor is operating, supply fan is on, and the reheat valve is de- energized. Heating Mode Thermostat or Zone Sensor (Up to 2 stages WI, W2) W1 demand: 1st: Gas valve is open (stage 1 on units with 2 stage gas valve), supply fan is on. W2 demand: 1st: Gas valve is open (stage 2 on units with 2 stage gas valve), supply fan is on. Energence° Packaged Gas / Electric 3 to 6 Ton / Page 21 COOLING RATINGS NOTE - For Temperatures and Capacities not shown in tables, see bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Product Data section. 3 TON STANDARD EFFICIENCY LGH036S4 (1ST STAGE) Entering Wet Bulb Temper- store Total Air Volume Outdoor Air Temperature Entering Outdoor Coil 65 °F 75°F 85 °F 95 °F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75 °F 80°F 85°F kBtuh kW 75°F 80 °F 85 °F kBtuh kW 75°F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F 83 °F 640 26.1 1.02 0.68 0.81 0.95 25.2 1.18 0.68 0.82 0.97 24.1 1.36 0.7 0.84 0.99 23 1.57 0.71 0.87 1 800 27.6 1.01 0.72 0.88 1 26.6 1.17 0.73 0.91 1 25.4 1.35 0.75 0.93 1 24.2 1.56 0.77 0.96 1 960 28.8 1 0.77 0.96 1 27.7 1.16 0.78 0.98 1 26.5 1.34 0.81 1 1 25.3 1.54 0.83 1 1 67 °F 640 27.7 1.01 0.54 0.65 0.76 26.7 1.17 0.54 0.66 0.78 25.6 1.35 0.55 0.67 0.8 24.3 1.55 0.56 0.69 0.82 800 29.2 1 0.56 0.7 0.84 28.1 1.16 0.57 0.71 0.86 26.9 1.34 0.58 0.72 0.89 25.6 1.54 0.59 0.74 0.92 960 30.3 0.99 0.59 0.74 0.92 29.2 1.15 0.6 0.76 0.94 27.8 1.33 0.61 0.78 0.97 26.4 1.53 0.62 0.81 1 71 °F 640 29.2 1 0.42 0.52 0.63 28.1 1.16 0.42 0.53 0.64 27 1.34 0.42 0.53 0.65 25.7 1.54 0.42 0.55 0.66 800 30.8 0.98 0.43 0.55 0.67 29.7 1.14 0.43 0.55 0.68 28.4 1.32 0.43 0.57 0.7 27 1.53 0.44 0.58 0.72 960 32.1 0.97 0.44 0.58 0.72 30.8 1.13 0.44 0.59 0.73 29.4 1.31 0.44 0.6 0.75 28 1.51 0.45 0.61 0.78 3 TON STANDARD EFFICIENCY LGH036S4 (2ND STAGE) Entering Wet Bulb Temper- afore Total Total Air Volume Air Temperature Entering Outdoor Coil 85°F 95 °F 105°F 115 °F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75 °F 80 °F 85°F kBtuh kW 75°F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75°F 80 °F 85 °F 63 °F 960 34.1 2.21 0.71 0.85 0.99 32.4 2.48 0.73 0.87 1 30.8 2.79 0.74 0.9 1 28.9 3.15 0.76 0.94 1 1200 35.7 2.23 0.77 0.94 1 34.1 2.5 0.78 0.96 1 32.3 2.82 0.81 0.99 1 30.4 3.18 0.83 1 1 1440 37 2.25 0.82 1 1 35.5 2.52 0.84 1 1 33.8 2.84 0.87 1 1 31.9 3.2 0.91 1 1 67 °F 960 35.9 2.24 0.56 0.69 0.82 34.3 2.51 0.57 0.7 0.84 32.5 2.82 0.58 0.72 0.87 30.5 3.18 0.59 0.74 0.9 1200 37.6 2.26 0.6 0.74 0.9 35.8 2.53 0.61 0.76 0.93 33.9 2.84 0.62 0.78 0.96 31.7 3.2 0.63 0.81 1 1440 38.7 2.27 0.63 0.8 0.98 36.9 2.54 0.63 0.82 1 34.9 2.86 0.66 0.85 1 32.7 3.22 0.67 0.89 1 71 °F 960 37.8 2.26 0.43 0.55 0.66 36 2.53 0.43 0.56 0.68 34.1 2.84 0.44 0.57 0.7 32.1 3.21 0.44 0.58 0.72 1200 39.5 2.29 0.44 0.58 0.72 37.7 2.56 0.45 0.59 0.74 35.6 2.87 0.45 0.61 0.76 33.5 3.23 0.46 0.63 0.79 1440 40.9 2.3 0.46 0.62 0.77 38.8 2.57 0.46 0.63 0.8 36.7 2.89 0.47 0.65 0.83 34.3 3.24 0.48 0.67 0.86 3 TON HIGH EFFICIENCY LGH036H4 (1ST STAGE) Entering Wet Bulb Temper- store Total Air Volume Outdoor Air Temperature Entering Outdoor Coil 65°F 75 °F 85 °F 95°F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SI1) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75°F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 751 80 °F 85 °F 63 °F 640 25.5 1.06 0.69 0.81 0.95 24.6 1.22 0.69 0.83 0.97 23.7 1.41 0.7 0.85 0.99 22.5 1.63 0.72 0.87 1 800 27 1.05 0.73 0.88 1 26 1.21 0.74 0.91 1 24.9 1.4 0.76 0.93 1 23.7 1.61 0.78 0.96 1 960 28.2 1.03 0.78 0.96 1 27.1 1.2 0.79 0.98 1 26 1.39 0.81 1 1 24.8 1.6 0.84 1 1 67 °F 640 27.1 1.05 0.55 0.66 0.77 26.1 1.21 0.55 0.67 0.79 25.1 1.4 0.55 0.68 0.81 23.9 1.61 0.57 0.7 0.83 800 28.6 1.03 0.57 0.71 0.85 27.6 1.2 0.58 0.72 0.87 26.4 1.38 0.59 0.73 0.89 25.1 1.6 0.6 0.75 0.92 960 29.7 1.02 0.6 0.75 0.92 28.6 1.19 0.61 0.77 0.94 27.3 1.37 0.61 0.78 0.97 25.9 1.59 0.64 0.81 1 71 °F 640 28.6 , 1.03 0.42 0.53 0.64 27.6 1.2 0.42 0.54 0.65 26.4 1.38 0.43 0.54 0.65 25.2 1.6 0.43 0.55 0.67 800 30.2 1.01 0.43 0.56 0.68 29.1 1.18 0.43 0.56 0.69 27.8 1.37 0.44 0.58 0.71 28.5 1.58 0.44 0.59 0.73 960 31.4 1 0.45 0.59 0.73 30.3 1.17 0.44 0.6 0.74 28.9 1.35 0.45 0.61 0.76 27.4 1.57 0.45 0.62 0.79 3 TON HIGH EFFICIENCY LGH036H4 (2ND STAGE) Entering Wet Bulb Temper- store Total Air Volume Outdoor Air Temperature Entering Outdoor Coil 85 °F 95°F 105 °F 115 °F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (911) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75 °F 80 °F 85i kBtuh kW 75 °F 80 °F 85°F kBtuh kW 75°F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F 63 °F 960 34 2.15 0.71 0.85 0.99 32.4 2.41 0.72 0.87 1 30.8 2.72 0.74 0.9 1 29 3.08 0.76 0.93 1 1200 35.7 2.17 0.77 0.93 1 34.1 2.44 0.78 0.96 1 32.3 2.74 0.81 0.99 1 30.4 3.1 0.83 1 1 1440 37 2.19 0.82 1 1 35.4 2.45 0.84 1 1 33.8 2.76 0.87 1 1 32 3.12 0.9 1 1 67 °F 960 35.9 2.17 0.57 0.69 0.82 34.3 2.44 0.57 0.7 0.84 32.5 2.74 0.58 0.72 0.86 30.6 3.1 0.6 0.74 0.9 1200 37.6 2.19 0.6 0.74 0.9 35.8 2.46 0.61 0.76 0.92 34 2.76 0.62 0.78 0.96 31.8 3.11 0.63 0.81 0.99 1440 38.8 2.21 0.63 0.8 0.97 36.9 2.47 0.64 0.82 1 34.9 2.77 0.66 0.84 1 32.7 3.13 0.67 0.88 1 71 °F 960 37.7 2.19 0.43 0.55 0.67 36 2.46 0.43 0.56 0.68 34.2 2.76 0.44 0.57 0.7 32.2 3.12 0.44 0.58 0.72 1200 39.6 2.22 0.44 0.58 0.72 37.7 2.48 0.44 0.59 0.74 35.7 2.79 0.46 0.61 0.76 33.6 3.14 0.46 0.62 0.79 1440 40.9 2.23 0.46 0.62 0.78 38.9 2.49 0.46 0.63 0.8 36.8 2.8 0.47 0.65 0.82 34.5 3.15 0.48 0.67 0.85 Energence® Packaged Gas / Electric 3 to 6 Ton / Page 22 COOLING RATINGS NOTE - For Temperatures and Capacities not shown in tables, see bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Product Data section. 4 TON STANDARD EFFICIENCY LGH048S4 (1ST STAGE) Entering Wet Bulb Tempe r• ature Total Air Volume Outdoor Air Temperature Entering Outdoor Coil 65 °F 75 °F 85 °F 95 °F Total Cool Ca . Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (S/T) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (S/T) Dry ry Bulb D ry Bulb Dry ry Bulb Dry ry Bulb cfm kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F 63 °F 850 37.2 1.49 0.65 0.78 0.92 36.1 1.72` 0.66 0.8. 0.95 34.6 1.98 0.68 0.82 0.97 32.9 2.27 0.69 0.84 1 1065 39:4. 1.47 0:7 0.86 _ 1 38 1.7 0.71- 0.88 1 36.4 1.96 0.72` 0.91 1 34.6; 2.26 074 0.93 1 1280 41 1.46 0.74 0.94 1 39.5 1.69 0.76 0.97 1 37.8 1.95 0.78 0.99 1 36.2 2.24 0.81 1 1 67 °F 850 39.7 1.47 0.52 0.63 0.74 38.2 1.7 0.53 0.64 0.75 36.7 1.96 0.54 0.64 0.77 35 2.25 0.55 0.67 0.8 1065 41.9 1.45 0.55 0.67 0.82 40.3 1.68 0.55 0.69 0.84 38.7 1.94 0.56 0.7 0.87 36.7 2.24 0.57 0.71 0.89 1280 43.5 1.44 0.57 0.72 0.9 41.9 1.67 0.57 0.74 0.92 39.9 1.93 0.58 0.75 0.95 38 2.23 0.6 0.78 0.99 71 °F 850 42.1 1.45 0.4 0.5 0.61 40.6 1.68 0.41 0.51 0.61 38.9 1.94 0.41 0.51 0.62 37.1 2.23 0.42 0.53 0.64 1065 44.4 1.43 0.41 0.54 0.65 42.7 1.66 0.42 0.55 0.66 40.9 1.92 0.42 0.55 0.66 38.8 2.22 0.42 0.56 0.69 1280 46 1.42 0.43 0.56 0.7 44.1 1.65 0.42 0.56 0.71 42.1 1.91 0.44 0.58 0.73 40 2.2 0.42 0.59 0.76 4 TON STANDARD EFFICIENCY LGH048S4 (2ND STAGE) Entering We Bulb Temper- ature Total Air Volume Outdoor Air Temperature Entering Outdoor Coll 85 °F 95 °F 105 °F 115 °F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (S/T) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75 °F 80 °F 85°F ki3tuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85°F kBtuh kW 75°F 80 °F 85 °F 63 °F 1280 47.8 2.83 0.7 0.85 1 45.4 3.15 0.72 0.87 1 43 3.51 0.73 0.91 1 40.3 3.93 0.75 0.94 1 1600 50 2.86 0.76 0.94 1 47.5 3.17 0.78. 0.97 1 44.9 3.54 0.8 1 1 42.5 3.97 0.83 1 1 1920 51.8 2.88 0.82 1 1 49.7 3.2 0.85 1 1 47.2 3.57 0.87 1 1 44.4 4 0.91 1 1 67 °F 1280 50.6 2.87 0.55 0.68 0.81 48.2 3.18 0.57 0.7 0.83 45.5 3.55 0.57 0.71 0.87 42.7 3.97 0.59 0.73 0.9 1600 52.9 2.9 0.59 0.73 0.9 50.1 3.21 0.6 0.75 0.93 47.3 3.57 0.6 0.77 0.97 44.2 4 0.62 0.81 1 1920 54.5 2.91 0.6 0.79 0.99 51.6 3.23 0.63 0.82 1 48.7 3.59 0.65 0.85 1 45.4 4.02 0.67 0.89 1 71°F 1280 53.4 2.9 0.42 0.53 0.65 50.9 3.22 0.42 0.56 0.67 48 3.58 0.43 0.56 0.69 45.1 4.01 0.44 0.58 0.71 1600 55.8 2.93 0.43 0.58 0.71 52.8 _3.24 0.44 0.58 0.73 49.9 3.61 0.44 0.6 0.75 46.7 4.04 0.45 0.62 0.79 1920 57.3 2.95 0.44 0.6 0.77 54.3 3.26 0.46 0.62 0.8 51.3 3.63 0.45 0.64 0.83 47.8 4.05 0.47 0.66 0.87 4 TON HIGH EFFICIENCY LGH048H4 (1ST STAGE) Entering Wet Bulb Tempe r- attire Total Air Volume Outdoor Air Temperature Entering Outdoor Coil 65°F 75 °F 85 °F 95 °F Total Cool Ca P• Comp. Motor Input Sensible To Total Ratio (S/T) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (S/T) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (511) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry ry Bulb Dry ry Bulb Dry ry Bulb Dry ry Bulb cfm kBtuh kW 75°F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85°F kBtuh kW 75°F 80 °F 85 °F 63 °F 850 37.1 1.54 0.67 0.79 0.93 35.9 1.78 0.67 0.81 0.95 34.4 2.05 0.69 0.83 0.97 32.7 2.35 0.7 0.85 1 1065 39.2 1.53 0.71 0.87 1 37.8 1.77 0.72 0.89 1 36.2 2.03 0.74 0.91 1 34.4 2.34 0.75 0.94 1 1280 40.9 1.52 0.76 0.94 1 39.4 1.76 0.77 0.97 1 37.6 2.02 0.79 0.99 1 36 2.32 0.82 1 1 67°F 850 39.5 1.53 0.53 0.64 0.75 38.1 1.76 0.54 0.65 0.77 36.6 2.03 0.55 0.66 0.79 34.8 2.34 0.56 0.68 0.81 1065 41.7 1.51 0.56 0.69 0.83 40.1 1.75 0.57 0.7 0.85 38.4 2.02 0.57 0.72 0.88 36.5 2.32 0.58 0.73 0.9 1280 43.2 1.5 0.58 0.73 0.9 41.7 1.74 0.58 0.75 0.93 39.7 2 0.59 0.77 0.96 37.7 2.31 0.62 0.79 0.99 71 °F 850 41.9 1.51 0.41 0.51 0.62 40.4 1.75 0.41 0.52 0.62 38.7 2.01 0.42 0.53 0.63 36.9 2.32 0.43 0.54 0.65 1065 44.2 1.49 0.42 0.55 0.67 42.5 1.73 0.42 0.56 0.68 40.6 1.99 0.43 0.56 0.69 38.5 2.3 0.43 0.57 0.7 1280 45.8 1.48 0.43 0.57 0.71 43.9 1.71 0.42 0.58 0.72 41.9 1.98 0.45 0.58 0.74 39.8 2.28 0.43 0.6 0.77 4 TON HIGH EFFICIENCY LGH048H4 (2ND STAGE) Entering Wet Bulb Temper- attire Total Air Volume Outdoor Air Temperature Entering Outdoor Coil 85°F 95°F 105 °F 115 °F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (S/T) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75°F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 76 °F 80 °F 85°F kBtuh kW 75 °F 80 °F 85°F 63 °F 1280 47.6 2.92 0.7 0.84 0.99 45.2 3.24 0.71 0.87 1 43 3.62 0.73 0.9 1 40.3 4.06 0.75 0.94 1 1600 49.9 2.95 0.76 0.94 1 47.4 3.27 0.77 0.96 1 44.9 3.64 0.8 0.99 1 42.3 4.09 0.83 1 1 1920 51.6 2.97 0.82 1 1 49.6 3.29 0.84 1 1 47.1 3.68 0.87 • 1 1 44.4 4.12 0.9 1 1 67 °F 1280 50.4 2.95 0.55 0.67 0.81 48 3.28 0.57 0.7 0.83 45.5 3.66 0.57 0.71 0.86 42.7 4.1 0.59 0.73 0.9 1600 52.7 2.98 0.59 0.73 0.9 50.1 3.3 0.6 0.75 0.92 47.3 3.68 0.6 0.77 0.96 44.3 4.12 0.62 0.8 1 1920 54.3 3 0.62 0.79 0.98 51.6 3.32 0.62 0.81 1 48.7 3.7 0.65 0.85 1 45.5 4.14 0.67 0.88 1 71 °F 1280 53.2 2.98 0.43 0.54 0.65 50.7 3.31 0.42 0.55 0.66 48 3.69 0.43 0.56 0.69 45.1 4.14 0.44 0.58 0.71 1600 55.6 3.01 0.44 0.58 0.71 52.8 3.33 0.44 0.59 0.73 49.9 3.71 0.44 0.6 0.75 46.8 4.16 0.45 0.62 0.78 1920 57.2 3.03 0.44 0.6 0.77 54.2 3.35 0.46 0.62 0.8 51.2 3.73 0.46 0.64 0.82 47.9 4.17 0.47 0.66 0.86 Energence• Packaged Gas / Electric 3 to 6 Ton / Page 23 COOLING RATINGS NOTE - For Temperatures and Capacities not shown in tables, see bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Product Data section. 5 TON STANDARD EFFICIENCY LGH060S4 (1ST STAGE) Entering Wet Bulb Tempe r- ature Total Air Volume Outdoor Air Temperature Entering Outdoor Coil 65 °F 75 °F 85°F 95 °F Total Cool Ca p' Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor In ut Sensible To Total Ratio (S!T) Total Cool Cap. Comp. Motor In ut Sensible To Total Ratio (SIT) Dry ry Bulb Dry ry Bulb Dry ry Bulb Dry Bulb cfm kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75°F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75°F 80 °F 85 °F 63 °F 1070 48 1.76 0.66 0.78 0.92 46.1 2.08 0.66 0.8 0.94 44.1 2.42 0.68 0.81 0.96 42.1 2.79 0.69 0.84 0.99 1335 50.8 1.75 0.7 0.85 1 48.8 2.07 0.71 0.88 1 46.7 2.41 0.73 0.9 1 44.4 2.78 0.74 0.93 1 1600 53 1.74 0.75 0.93 1 50.8 2.06 0.76 0.95 1 48.6 2.4 0.78 0.97 1 46.1 2.77 0.8 1 1 67 °F 1070 51.2 1.75 0.53 0.64 0.74 49 2.06 0.53 0.64 0.76 46.9 2.41 0.53 0.65 0.78 45.1 2.78 0.54 0.67 0.79 1335 54.1 1.73 0.55 0.67 0.81 52 2.06 0.56 0.69 0.83 49.7 2.4 0.57 0.7 0.66 47.4 2.78 0.58 0.72 0.88 1600 56.4 1.72 0.58 0.72 0.89 54 2.05 0.58 0.73 0.91 51.6 2.39 0.57 0.75 0.93 49 2.77 0.6 0.78 0.97 71 °F 1070 54.4 1.73 0.41 0.51 0.61 52.3 2.05 0.41 0.51 0.62 50 2.4 0.4 0.51 0.62 47.7 2.77 0.41 0.52 0.64 1335 57.5 1.72 0.41 0.54 0.65 55.2 2.05 0.42 0.55 0.67 52.7 2.39 0.42 0.55 0.68 50.2 2.77 0.43 0.56 0.69 1600 59.8 1.71 0.43 0.56 0.69 57.4 2.04 0.43 0.57 0.71 54.6 2.39 0.42 0.57 0.72 51.9 2.76 0.44 0.59 0.75 5 TON STANDARD EFFICIENCY LGH060S4 (2ND STAGE) Entering Wet Bulb Temper- ature Total Air Volume Outdoor Air Temperature Entering Outdoor Coll 85 °F 95 °F 105°F 115 °F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75°F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F 63 °F 1600 59.5 3.42 0.69 0.84 0.98 56.9 3.84 0.71 0.86 1 54.1 4.33 0.73 0.89 1 51 4.89 0.75 0.92 1 2000 62.6 3.46 0.75 0.93 1 59.7 3.87 0.77 0.95 1 56.6 4.36 0.78 0.98 1 53.3 4.92 0.82 1 1 2400 64.9 3.48 0.8 0.99 1 62.1 3.9 0.83 1 1 59.5 4.39 0.85 1 1 56.4 4.97 0.69 1 1 67°F 1600 62.9 3.46 0.55 0.67 0.8 60.3 3.88 0.56 0.69 0.82 57.4 4.37 0.57 0.7 0.85 54 4.93 0.58 0.72 0.88 2000 66.3 3.5 0.59 0.73 0.88 63.3 3.92 0.6 0.74 0.91 60 4.4 0.6 0.76 0.94 56.6 4.97 0.62 0.79 0.98 2400 68.4 3.52 0.61 0.77 0.96 65.3 3.94 0.63 0.8 0.99 61.8 4.42 0.64 0.82 1 58.1 4.98 0.65 0.86 1 71 °F 1600 66.9 3.5 0.42 0.53 0.65 63.9 3.92 0.43 0.54 0.66 60.8 4.41 0.43 0.56 0.68 57.4 4.98 0.43 0.57 0.7 2000 70 3.54 0.44 0.57 0.7 66.8 3.96 0.44 0.58 0.72 63.4 4.44 0.44 0.59 0.73 59.7 5.01 0.45 0.6 0.76 2400 72.2 3.57 0.44 0.6 0.75 69 3.99 0.44 0.61 0.78 65.2 4.47 0.47 0.63 0.8 61.5 5.03 0.46 0.64 0.83 5 TON HIGH EFFICIENCY LGH060H4 (1ST STAGE) Entering Wet Bulb Temper- ature Total Air Volume Outdoor Air Temperature Entering Outdoor Coil 65 °F 75 °F 85 °F 95 °F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (S!T) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75°F 80 °F 85 °F kBtuh kW 76 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F 63 °F 1070 47.4 1.82 0.66 0.79 0.92 45.5 2.14 0.67 0.8 0.94 43.5 2.49 0.68 0.82 0.97 41.5 2.87 0.7 0.85 0.99 1335 50.1 1.81 0.71 0.85 1 48.2 2.13 0.72 0.88 1 46 2.48 0.73 0.91 1 43.7 2.86 0.75 0.93 1 1600 52.3 1.8 0.75 0.93 1 50 2.13 0.77 0.95 1 47.9 2.48 0.79 0.98 1 45.5 2.86 0.8 1 1 67 °F 1070 50.4 1.81 0.53 0.64 0.75 48.5 2.13 0.53 0.65 0.76 46.2 2.48 0.53 0.65 0.78 44.2 2.86 0.55 0.67 0.8 1335 53.3 1.8 0.55 0.68 0.82 51.2 2.13 0.57 0.69 0.84 49 2.48 0.57 0.71 0.86 46.7 2.86 0.58 0.72 0.89 1600 55.6 1.79 0.58 0.72 0.89 53.2 2.12 0.59 0.73 0.91 50.8 2.48 0.57 0.76 0.94 48.2 2.86 0.61 0.78 0.97 71 °F 1070 53.6 1.8 0.41 0.51 0.62 51.5 2.12 0.41 0.52 0.62 49.3 2.47 0.41 0.52 0.63 47 2.86 0.42 0.53 0.65 1335 56.7 1.79 0.42 0.54 0.66 54.4 2.12 0.43 0.55 0.67 51.9 2.47 0.43 0.56 0.68 49.5 2.86 0.43 0.57 0.7 1600 58.9 1.78 0.43 0.57 0.7 56.5 2.12 0.44 0.58 0.71 53.9 2.47 0.44 0.58 0.72 51.2 2.86 0.45 0.6 0.75 5 TON HIGH EFFICIENCY LGH060H4 (2ND STAGE) Entering Wet Bulb Temper- ature Total Air Volume Outdoor Air Temperature Entering Outdoor Coil 85 °F 95 °F 105 °F 115 °F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Coot Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75 °F 80 °F 85i kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 76 °F 80 °F 85°F kBtuh kW 75 °F 80 °F 85 °F 63 °F 1600 59.5 3.5 0.69 0.84 0.99 56.9 3.93 0.71 0.86 1 54 4.42 0.73 0.89 1 50.9 4.99 0.75 0.93 1 2000 62.6 3.54 0.75 0.93 1 59.7 3.96 0.77 0.95 1 56.5 4.45 0.79 0.98 1 53.3 5.02 0.82 1 1 2400 64.9 3.56 0.8 1 1 62.2 3.99 0.83 1 1 59.4 4.49 0.85 1 1 56.3 5.07 0.9 1 1 67 °F 1600 63 3.54 0.54 0.67 0.8 60.2 3.97 0.56 0.68 0.82 57.3 4.46 0.57 0.7 0.85 53.9 5.03 0.58 0.72 0.88 2000 66.4 3.58 0.59 0.73 0.89 63.2 4.01 0.59 0.74 0.92 59.7 4.5 0.6 0.76 0.94 56.4 5.07 0.62 0.79 0.98 2400 68.4 3.61 0.61 0.78 0.97 65.2 4.03 0.63 0.8 0.99 61.6 4.52 0.64 0.83 1 58 5.09 0.65 0.87 1 71 °F 1600 66.8 3.59 0.42 0.53 0.64 63.9 4.01 0.42 0.54 0.66 60.8 4.51 0.43 0.56 0.68 57.3 5.08 0.44 0.57 0.7 2000 70.1 3.63 0.43 0.57 0.7 66.8 4.05 0.44 0.58 0.72 63.2 4.54 0.44 0.58 0.74 59.6 5.12 0.44 0.6 0.76 2400 72.3 3.65 0.45 0.6 0.76 68.8 4.08 0.45 0.61 0.77 65.2 4.57 0.46. 0.63 0.8 61.4 5.14 0.46 0.65 0.84 Energence° Packaged Gas / Electric 3 to 6 Ton / Page 24 COOLING RATINGS NOTE - For Temperatures and Capacities not shown in tables, see bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Product Data section. 6 TON HIGH EFFICIENCY LGH072H4 Entering Wet Bulb Temper- ature Total Air Volume Outdoor Air Temperature Enter ng Outdoor Coil 85°F 95°F 105°F 115°F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75i 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75 °F 80°F 85°F 63 °F 1920 72.3 ' 4.53 0.71 0.85 0.99 69.1 5.05 0:73 0.87 1 65.7 5.63. 0.74 .0.9 ` -1 61:8 6.28 0.76 ' 0.93 1 2400 762 4.55 0.76 ,0.93 1 72.8 `5.06 0.78 0.96 1 69 5.63 0.8 0.98 .1 64.9 628 0.82 1 1 2880 - 79 4.56 0.82 1 1 75.6` . 5.06 0.84 1 1 72.5 5.64 0.86. 1`< 1 68.8 6:31 0.9 1 1 67°F 1920 76.7 4.55 0.56 0.68 0.81 73.3 5.05 0.57 0.69 0.83 69.9 5.64 0.58 0.72 0.86 66 6.29 0.59 0.73 0.89 2400 80.8 4.56 0.59 0.74 0.89 77.2 5.07 0.6 0.75 0.92 73.2 5.65 0.62 0.77 0.95 68.9 6.3 0.63 0.8 0.98 2880 83.6 4.57 0.63 0.79 0.97 79.7 5.07 0.63 0.81 0.99 75.8 5.65 0.65 0.84 1 71 6.3 0.66 0.87 1 71 °F 1920 81:6 4.56 0.43 0.55 0.66 78.1 5.07 0.43 0.55 0.67 74.4 5.65 0.43 0.56 0.69 70.1 6.3 0.44 0.58 0.71 2400 85.7 4.58 0.44 0.58 0.71 81.8 5.08 0.45 0.59 0.73 77.7 5.66 0.45 0.6 0.75 73.1 6.31 0.46 0.62 0.77 2880 88.4 4.59 0.46 0.61 0.77 84.4 5.09 0.46 0.62 0.79 80 5.67 0.46 0.63 0.8 75.5 6.32 0.47 0.65 0.84 Energencee Packaged Gas / Electric 3 to 6 Ton / Page 25 i HUMIDITROL® DEHUMIDIFICATION SYSTEM RATINGS 3 TON STANDARD EFFICIENCY LGH036S4 WITH HUMIDITROL OPERATING Ent ng Wet Bulb Temper- ature Total Air Vol- ume Outdoor Air Temperature Entering Outdoor Coil 65 °F 75 °F 85 °F 95 °F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F 63 °F 640 22.5 1.69 .46 .60 .76 19.3 1.88 .40 .57 .75 16.0 2.10 .32 .53 .74 12.5 2.35 .21 .46 .73 800 23.9 1.71 .49 .67 .84 20.1 1.91 .44 .64 .86 16.2 2.13 .36 .61 .88 12.3 2.38 .24 .56 .90 960 24.7 1.73 .53 .74 .95 20.5 1.93 .46 .73 .97 16.1 2.15 .39 .71 1.00 12.3 2.40 .27 .62 1.00 67 °F 640 25.1 1.71 .32 .44 .57 21.9 1.90 .26 .40 .54 18.5 2.13 .18 .34 .51 15.0 2.37 .05 .25 .45 800 26.7 1.74 .33 .48 .26 22.9 1.93 .27 .44 .61 19.1 2.15 .18 .37 .58 15.0 2.40 .03 .28 .54 960 27.8 1.76 .35 .52 .70 23.5 1.95 .28 .48 .69 19.2 2.17 .18 .41 .68 14.6 2.42 .02 .32 .66 71 °F 640 28.0 1.73 .20 .31 .43 24.5 1.93 .15 .27 .39 21.0 2.15 .06 .20 .34 17.5 2.40 -.07 .10 .27 800 29.6 1.76 .21 .34 .47 25.7 1.96 .14 .28 .43 21.7 2.18 .04 .21 .38 17.6 2.43 -.11 .10 .31 960 30.7 1.78 .21 .36 .51 26.5 1.98 .13 .30 .47 22.0 2.20 .02 .22 .42 17.4 2.45 -.15 .11 .35 3 TON HIGH EFFICIENCY LGH036H4 WITH HUMIDITROL OPERATING Entering Wet Bulb Temper- ature Total Air Vol- ume Outdoor Air Temperature Entering Outdoor Coll 65 °F 75 °F 85 °F 95 °F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80°F 85 °F kBtuh kW 75 °F 80 °F 85°F kBtuh kW 75°F 80 °F 85 °F 63 °F 640 22.8 1.66 .46 .61 .76 19.7 1.86 .40 .57 .75 16.3 2.07 .33 .53 .74 12.9 2.32 .23 .47 .73 800 24.3 1.69 .50 .67 .85 20.6 1.88 .44 .64 .85 16.7 2.10 .37 .61 .67 12.7 2.35 .25 .57 .91 960 25.2 1.71 .53 .74 .94 21.0 1.90 .48 .72 .97 16.6 2.12 .41 .71 1.00 12.2 2.37 .29 .69 1.00 67 °F 640 25.5 1.69 .32 .45 .58 22.2 1.88 .26 .40 .55 18.9 2.10 .18 .34 .51 15.3 2.35 .07 .26 .46 800 27.1 1.71 .34 .48 .63 23.4 1.91 .27 .44 .61 19.5 2.12 .19 .38 .59 15.4 2.37 .05 .29 .55 960 28.3 1.73 .35 .52 .70 24.0 1.93 .29 .48 .68 19.7 2.14 .19 .42 .68 15.1 2.39 .05 .34 .65 71 °F 640 28.2 1.71 .21 .32 .44 24.9 1.90 .16 .27 .40 21.4 2.12 .07 .21 .35 17.9 2.37 -.05 .12 .28 800 30.0 1.73 .22 .34 .47 26.2 1.93 .15 .29 .44 22.2 2.15 .05 .22 .38 18.1 2.39 -.09 .12 .32 960 31.3 1.75 .22 .36 .51 27.0 1.95 .15 .31 .48 22.6 2.17 .04 .23 .43 18.2 2.41 -.13 .12 .36 4 TON STANDARD EFFICIENCY LGH048S4 WITH HUMIDITROL OPERATING Entering Wet Bulb Temper- ature Total Air Vol- ume Outdoor Air Temperature Entering Outdoor Coil 65 °F 75 °F 85 °F 95°F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SR) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (S/T) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SR) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75°F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F 63 °F 890 30.8 2.24 .47 .62 .77 26.8 2.48 .42 .60 .77 22.7 2.75 .36 .56 .76 18.2 3.05 .27 .52 .76 1115 32.6 2.28 .51 .68 .86 27.9 2.52 .47 .67 .87 23.2 2.78 .41 .65 .89 18.3 3.08 .31 .61 .92 1340 33.7 2.31 .55 .76 .96 28.6 2.55 .51 .75 .98 23.3 2.81 .45 .73 1.00 17.8 3.11 .35 .73 .99 67°F 890 34.5 2.28 .33 .46 .59 30.4 2.52 .28 .42 .56 26.1 2.78 .20 .37 .54 21.7 3.08 .10 .30 .50 1115 36.4 2.31 .35 .50 .66 31.8 2.55 .29 .45 .63 26.8 2.82 .21 .41 .61 21.7 3.11 .09 .34 .59 1340 37.7 2.34 .37 .54 .72 33.0 2.58 .31 .48 .71 27.0 2.84 .21 .45 .70 21.4 3.14 .09 .39 .69 71 °F 890 38.1 2.31 .22 .33 .44 34.0 2.55 .16 .29 .41 29.6 2.81 .08 .22 .36 25.2 3.12 -.03 .14 .31 1115 40.3 2.35 .22 .35 .48 35.5 2.56 .15 .30 .45 30.5 2.85 .06 .24 .41 25.4 3.15 -.07 .15 .35 1340 41.6 2.37 .22 .38 .53 36.8 2.61 .15 .31 .50 31.0 2.87 .05 .25 .46 25.2 3.17 -.10 .15 .40 4 TON HIGH EFFICIENCY LGH048H4 WITH HUMIDITROL OPERATING Entering Wet Bulb Temper- ature Total Air Vol- ume Outdoor Air Temperature Enter ng Outdoor Coil 65 °F 75 °F 85°F 95 °F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SR) Total Cool Cap. Comp. Motor input Sensible To Total Ratio (SR) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (S/T) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (S/7) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75 °F 80 °F 85°F kBtuh kW 75 °F 80 °F 85°F kBtuh kW 75°F 80 °F 85°F kBtuh kW 75 °F 80 °F 85 °F 63 °F 890 30.1 2.28 .46 .62 .77 26.1 2.52 .41 .59 .76 22.0 2.79 .35 .56 .76 17.6 3.09 .26 .51 .76 1115 31.8 2.32 .51 .68 .86 27.2 2.56 .46 .66 .87 22.4 2.83 .40 .64 .89 17.5 3.13 .29 .60 .92 1340 32.8 2.35 .55 .76 .96 27.7 2.59 .50 .74 .98 22.3 2.85 .44 .74 1.00 17.0 3.16 .33 .72 1.00 67°F 890 33.8 2.32 .32 .46 .59 29.7 2.56 .27 .41 .56 25.5 2.83 .19 .36 .53 21.1 3.13 .08 .28 .49 1115 35.7 2.36 .34 .49 .65 30.8 2.59 .28 .46 .63 26.0 2.86 .19 .40 .61 20.9 3.16 .05 .33 .58 1340 36.7 2.38 .36 .54 .72 32.1 2.62 .30 .47 .67 26.1 2.89 .19 .45 .70 20.5 3.19 .06 .37 .69 71 °F 890 37.4 2.35 .21 .32 .44 33.3 2.59 .15 .27 .40 28.9 2.86 .07 .21 .36 24.5 3.17 -.05 .12 .29 1115 39.4 2.39 .21 .34 .48 34.6 2.63 .14 .29 .45 29.8 2.90 .04 .22 .40 24.5 3.20 -.09 .13 .34 1340 40.5 2.42 .21 .37 .53 35.9 2.65 .13 .30 .49 30.0 2.92 .02 .24 .45 24.2 3.23 -.14 .13 .39 Energence® Packaged Gas / Electric 3 to 6 Ton / Page 26 HUMIDITROL® DEHUMIDIFICATION SYSTEM RATINGS 5 TON STANDARD EFFICIENCY LGH060S4 WITH HUMIDITROL OPERATING Entering Wet Bulb Temper- attire Total Air Vol- ume Outdoor Air Temperature Entering Outdoor Coil 65 °F 75°F 85 °F 95°F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75°F 80 °F 85°F kBtuh kW 75 °F 80 °F 85°F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85i 63 °F 1080 39.4 2.94 .42 .58 .73 33.2 3.27 .35 .53 .71 26.8 3.64 .25 .46 .69 20.0 4.07 .08 .36 .66 1350 41.7 2.99 .47 .64 .82 34.7 3.31 .39 .60 .83 27.2 3.69 .28 .55 .83 19.4 4.12 .09 .46 .85 1620 43.3 3.03 .50 .71 .92 35.1 3.35 .43 .69 .96 28.2 3.72 .31 .59 .99 18.4 4.15 .10 .58 1.00 67°F 1080 44.8 2.99 .28 .41 .55 38.6 3.31 .21 .35 .51 32.1 3.69 .10 .27 .45 25.1 4.12 -.08 .15 .38 1350 47.4 3.04 .30 .46 .61 40.3 3.36 .21 .39 .58 32.8 3.73 .09 .31 .53 24.9 4.16 -.11 .18 .46 1620 49.3 3.08 .31 .49 .67 41.3 3.40 .24 .44 .66 32.7 3.77 .07 .36 .62 24.2 4.20 -.14 .21 .56 71 °F 1080 50.5 3.04 .17 .29 .40 44.1 3.36 .09 .22 .35 37.4 3.73 -.01 .14 .29 30.5 4.16 -.18 .01 .19 1350 53.4 3.09 .17 .31 .45 46.0 3.41 .09 .24 .40 38.4 3.78 -.04 .14 .33 30.7 4.22 -.23 .00 .22 1620 55.3 3.14 .17 .33 .48 47.2 3.45 .08 .26 .44 39.0 3.82 -.06 .15 .37 30.6 4.25 -.29 -.02 .26 5 TON HIGH EFFICIENCY LGH060H4 WITH HUMIDITROL OPERATING Entering Wet Bulb Temper- ature Total Air Vol- ume Outdoor Air Temperature Entering Outdoor Coil 651 75 °F 85 °F 95 °F Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total .Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb dm kBtuh kW 75°F 80 °F 85 °F kBtuh kW 75°F 80 °F 85°F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F 63 °F 1080 38.7 2.98 .41 .57 .73 32.6 3.31 .34 .52 .71 26.2 3.69 .23 .45 .69 19.4 4.12 .06 .35 .66 1350 40.8 3.03 .45 .64 .82 33.7 3.35 .38 .60 .83 • 26.4 3.73 .26 .54 .84 18.6 4.16 .06 .45 .86 1620 42.3 3.07 .49 .71 .93 34.8 3.39 .42 .66 .96 27.2 3.77 .30 .59 1.00 17.5 4.20 .07 .57 1.00 67°F 1080 44.0 3.02 .27 .41 .55 37.8 3.35 .19 .35 .51 31.4 3.73 .08 .26 .45 24.6 4.17 -.10 .13 .36 1350 46.6 3.08 .29 .45 .61 39.2 3.40 .20 .39 .57 31.9 3.78 .08 .30 .52 23.9 4.21 -.14 .16 .45 1620 48.2 3.12 .30 .49 .67 40.3 3.45 .22 .43 .65 32.8 3.82 .05 .31 .62 23.1 4.25 -.18 .19 .55 71 °F 1080 49.6 3.08 .17 .28 .40 43.3 3.40 .08 .21 .35 36.5 3.78 -.03 .13 .28 29.6 4.22 -.20 .00 .18 1350 52.4 3.13 .16 .30 .44 45.1 3.46 .08 .23 .39 37.4 3.83 -.06 .13 .32 29.6 4.27 -.26 -.02 .21 1620 54.3 3.18 .16 .32 .48 46.1 3.50 .06 .25 .43 38.0 3.87 -.08 .13 .36 29.4 4.30 -.33 -.04 .25 6 TON HIGH EFFICIENCY LGH072H4 WITH HUMIDITROL OPERATING Entering Wet Bulb Temper- ature Total Air Vol- ume Outdoor Air Temperature Entering Outdoor Coil 65 °F 75 °F 85°F 95°F Total Cool Cap. Comp. Motor Input Sens ble To Total Ratio (S T) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Total Cool Cap. Comp. Motor Input Sensible To Total Ratio (SIT) Dry Bulb Dry Bulb Dry Bulb Dry Bulb cfm kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F kBtuh kW 75 °F 80 °F 85 °F 63 °F 1920 49.0 3.62 .52 .73 .94 41.2 3.99 .44 .70 .98 32.1 4.40 .36 .69 1.00 23.0 4.85 .18 .65 1.00 2400 50.4 3.65 .57 .84 1.00 41.0 4.01 .52 .84 1.00 31.0 4.41 .42 .86 1.00 20.8 4.86 .26 .88 .89 2880 51.1 3.66 .65 .95 .95 40.7 4.03 .61 .98 1.00 29.8 4.43 .52 1.00 .99 19.6 4.87 .34 1.00 1.00 67 °F 1920 55.5 3.65 .32 .51 .69 47.2 4.02 .24 .46 .67 39.1 4.42 .10 .36 .65 29.2 4.87 -.09 .27 .61 2400 57.4 3.68 .35 .57 .79 47.6 4.04 .26 .53 .79 37.9 4.44 .11 .45 .79 27.6 4.88 -.14 .33 .79 2880 58.4 3.70 .37 .63 .89 47.6 4.05 .28 .60 .92 36.4 4.45 .13 .55 .96 25.3 4.89 -.17 .44 1.00 71 °F 1920 62.1 3.68 .17 .33 .49 53.6 4.04 .07 .27 .45 44.6 4.44 -.07 .17 .40 35.4 4.89 -.28 .02 .31 2400 64.2 3.71 .17 .36 .56 54.5 4.06 .06 .29 .52 44.5 4.46 -.10 .19 .46 34.2 4.91 -.38 .02 .38 2880 65.2 3.73 .17 .40 .62 54.7 4.08 .05 .32 .59 43.6 4.48 -.14 .22 .56 32.1 4.92 -.49 .03 .48 Energence° Packaged Gas / Electric 3 to 6 Ton / Page 27 8Z e6ed / eel. 9 o3 E 3143013 / 8e9 pawed ,eaue6Jeu3 BLOWER DATA - DIRECT DRIVE - 3 TON BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE.FOR ALL UNITS ADD: 1 -Any factory installed options air resistance (heat section, economizer, etc.). 2 -Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 39 for wet coil and options /accessory air resistance data. NOTE - Default Speed Settings (percentage of blower torque) - Low 28% / High 55% DOWNFLOW External Static Press. in. w.g. Percentage of Total Motor Torque 20% 30% 40% 50% 60% 70% 80% 90% 100% Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM 0 796 39 407 975 69 451 1154 98 494 1298 140 567 1442 181 639 1570 236 692 1697 292 744 1807 357 785 1917 422 825 0.1 719 44 482 915 76 523 1110 108 564 1257 151 626 1404 193 687 1537 248 733 1670 304 779 1784 369 815 1898 433 850 0.2 663 49 538 864 83 585 1064 117 633 1220 160 679 1375 203 725 1508 259 770 1641 316 815 1754 384 853 1866 452 891 0.3 593 55 607 806 91 651 1018 126 695 1174 171 737 1330 216 780 1471 272 815 1612 328 850 1724 398 890 1835 469 930 0.4 527 60 665 749 97 708 971 135 751 1136 180 783 1300 225 815 1435 285 858 1569 344 900 1689 413 930 1809 481 959 0.5 460 65 722 692 104 761 924 143 801 1090 190 833 1256 238 866 1398 296 899 1540 355 932 1662 424 960 1784 493 988 0.6 - -- - -- - -- - -- - -- - -- 855 154 864 1033 202 889 1211 250 914 1361 308 939 1511 365 963 1629 437 995 1746 508 1028 0.7 - -- - -- - -- - -- - -- - - - 808 161 898 995 209 922 1181 258 946 1325 319 976 1468 379 1007 1588 450 1036 1708 522 1065 0.8 - -- - -- - -- - -- - -- - -- 743 170 942 940 220 966 1137 269 991 1281 331 1020 1425 392 1049 1548 463 1074 1670 533 1100 0.9 - -- - -- - -- - -- - -- - -- 676 178 979 884 229 1006 1092 280 1033 1237 342 1061 1381 404 1088 1513 472 1105 1645 539 1121 1.0 - -- - -- - -- - -- - -- - -- 605 187 1011 819 240 1049 1032 294 1087 1192 353 1100 1352 411 1112 1474 480 1137 1595 549 1161 1 . 1 - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 988 304 1124 1142 364 1141 1295 424 1158 1420 490 1177 1544 555 1195 -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 1251 433 1189 1373 495 1207 1494 558 1225 HORIZONTAL Extemal Static Press. In. w.g. Percentage of Total Motor Torque 20% 30% 40% 50% 60% 70% 80% 90% 100% Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM 0 807 44 372 982 65 431 1157 86 490 1299 126 546 1441 167 602 1565 214 647 1688 262 692 1795 328 734 1901 393 776 0.1 708 50 468 906 77 513 1103 104 559 1247 143 612 1391 183 666 1522 231 704 1652 280 742 1766 346 779 1879 413 815 0.2 634 56 541 841 88 583 1048 120 625 1206 156 663 1363 192 701 1491 243 742 1619 294 783 1731 361 820 1843 429 857 0.3 523 63 648 759 98 669 994 134 690 1150 171 729 1306 209 769 1446 258 796 1585 307 823 1696 376 860 1807 444 896 0.4 437 69 732 688 107 742 939 146 752 1101 183 785 1263 221 818 1399 273 849 1535 326 881 1653 392 908 1771 458 935 0.5 344 75 823 615 116 817 885 156 812 1053 194 838 1220 232 865 1361 285 892 1502 339 918 1614 406 949 1725 473 980 0.6 - -- - -- - -- - -- - -- - -- 817 167 883 990 207 905 1162 246 927 1307 301 949 1451 356 971 1570 420 993 1689 484 1014 0.7 - -- - -- - -- - -- - -- - -- 762 174 938 941 215 954 1119 256 971 1269 312 988 1418 367 1005 1536 430 1026 1653 494 1047 0.8 - -- - -- - -- - -- - -- - -- 708 178 991 892 222 1002 1076 266 1013' 1222 324 1034 1368 383 1054 1484 444 1073 1599 506 1092 0.9 - -- - -- - -- - -- - -- - -- 645 182 1050 832 230 1059 1019 277 1068 1168 337 1084 1317 397 1100 1431 456 1117 1545 516 1134 1.0 - -- - -- - -- - -- - -- - -- 584 184 1105 780 235 1106 976 285 1107 1122 348 1125 1267 411 1144 1379 467 1158 1491 522 1172 1 . 1 - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 923 295 1155 1070 359 1169 1217 423 1184 1327 475 1195 1436 526 1207 - -- - - -- - -- - -- -- 1166 434 1222 1265 481 1234 1364 527 1246 Energencee Packaged Gas / Electric 3 to 6 Ton / Page 29 BLOWER DATA - DIRECT DRIVE - 4 TON BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE.FOR ALL UNITS ADD: 1 -Any factory installed options air resistance (heat section, economizer, etc.). 2 -Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 39 for wet coil and options /accessory air resistance data. NOTE - Default Speed Settings (percentage of blower torque) - Low 40% / High 80% DOWNFLOW Extemal Static Press. In. w.g. Percentage of Total Motor Torque 20% 30% 40% 50% 60% 70% 80% 90% 100% Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM 0 1048 80 507 1261 135 582 1473 190 657 1655 274 729 1836 359 801 1987 461 863 2137 563 924 2291 698 975 2445 832 1025 0.1 1000 88 560 1218 146 633 1436 204 706 1624 289 771 1812 374 836 1965 479 896 2118 583 956 2261 716 1004 2403 849 1052 0.2 944 97 624 1177 156 683 1409 214 743 1595 304 812 1781 393 881 1940 497 934 2098 602 986 2235 729 1032 2372 856 1077 0.3 906 104 666 1139 166 728 1372 228 790 1561 320 858 1750 412 925 1915 515 970 2079 619 1015 2210 741 1058 2341 863 1100 0.4 849 113 728 1093 177 783 1336 241 837 1531 333 897 1726 425 957 1889 532 1004 2052 639 1051 2177 754 1090 2302 869 1129 0.5 793 121 790 1047 188 837 1300 254 883 1501 346 935 1702 438 987 1864 548 1036 2026 657 1085 2145 766 1120 2263 874 1155 0.6 - -- - -- - -- - -- - -- - -- 1263 267 929 1467 361 978 1671 454 1027 1836 564 1071 2000 673 1116 2116 775 1145 2232 876 1175 0.7 - -- - -- - -- - -- - -- - -- 1226 280 974 1433 375 1019 1639 470 1065 1807 578 1104 1974 686 1144 2080 782 1173 2186 878 1203 0.8 - -- - -- - -- - -- - -- - -- 1195 291 1012 1402 388 1057 1608 485 1101 1778 591 1135 1948 697 1169 2052 787 1195 2155 878 1220 0.9 - -- - -- - -- - -- - -- - -- 1162 304 1060 1367 401 1097 1572 498 1134 1741 603 1168 1909 708 1202 2009 792 1223 2109 875 1244 1.0 - -- - -- - -- - -- - -- - -- 1133 316 1104 1333 414 1136 1533 511 1167 1702 612 1198 1870 714 1229 1959 791 1251 2047 868 1272 1 . 1 - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 1490 524 1200 1654 618 1228 1817 713 1256 1909 786 1273 2000 859 1289 -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 1765 701 1272 1844 771 1293 1923 840 1314 HORIZONTAL External Static Press. In. w.g. Percentage of Total Motor Torque 20% 30% 40% 50% 60% 70% 80% 90% 100% Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM 0 1025 80 472 1238 131 552 1450 182 632 1626 254 702 1802 326 771 1936 414 824 2071 502 878 2231 634 931 2391 767 983 0.1 978 85 546 1199 138 610 1420 191 675 1601 265 738 1781 339 801 1930 441 862 2079 544 923 2222 663 968 2365 783 1013 0.2 927 89 602 1157 145 661 1387 201 720 1568 279 783 1749 357 845 1906 458 897 2062 559 949 2205 679 993 2348 798 1038 0.3 851 98 684 1098 156 731 1344 214 777 1531 295 833 1717 375 888 1876 478 938 2035 581 988 2166 694 1030 2297 807 1072 0.4 801 105 738 1051 166 785 1300 227 832 1493 309 881 1685 392 930 1847 496 977 2009 600 1023 2128 707 1064 2247 813 1105 0.5 725 118 817 991 179 850 1256 239 883 1455 324 926 1653 408 970 1814 516 1019 1974 623 1068 2091 720 1099 2207 817 1130 0.6 - -- - -- - -- - -- - -- - -- 1212 251 931 1417 337 969 1621 423 1008 1784 531 1053 1947 638 1098 2057 729 1126 2166 820 1154 0.7 - -- - -- - -- - -- - -- - -- 1169 263 975 1380 350 1010 1590 437 1045 1756 544 1086 1921 651 1127 2014 736 1157 2106 821 1187 0.8 - -- - -- - -- - -- - -- - -- 1114 277 1027 1331 366 1059 1547 454 1091 1717 560 1126 1886 666 1161 1976 743 1184 2066 821 1207 0.9 - -- - -- - -- - -- - -- - -- 1062 290 1077 1283 380 1106 1504 470 1135 1669 575 1170 1833 680 1204 1919 749 1220 2005 817 1236 1.0 - -- - -- - -- - -- - -- - -- 1007 304 1127 1240 392 1147 1473 481 1166 1627 584 1202 1780 687 1238 1853 748 1253 1925 809 1269 1.1 - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 1429 497 1211 1569 590 1240 1709 683 1269 1787 741 1280 1864 799 1291 -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 1604 651 1284 1684 714 1303 1763 777 1321 BLOWER DATA - DIRECT DRIVE - 5 TON BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE.FOR ALL UNITS ADD: 0 k 1 -Any factory installed options air resistance (heat section, economizer, etc.). 2 -Any field installed accessories air resistance (duct resistance, diffuser, etc.). m See page 39 for wet coil and options/accessory air resistance data. n NOTE - Default Speed Settings (percentage of blower torque) - Low 36% / High 59% m 0 m 0 0 m m 0 DOWNFLOW External Static Press. In. w.g. Percentage of Total Motor Torque 20% 30% 40% 50% 60% 70% 80% 90% 100% Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM 0 1132 79 438 1353 146 524 1575 212 610 1765 300 670 1954 388 730 2126 513 796 2298 638 861 2445 792 913 2591 946 965 0.1 1061 86 494 1305 155 568 1548 223 641 1743 315 702 1937 407 764 2110 531 823 2282 654 883 2426 808 935 2570 963 987 0.2 990 94 550 1253 165 614 1516 236 678 1716 330 735 1916 423 793 2088 549 851 2260 675 910 2405 827 959 2549 979 1009 0.3 920 102 606 1202 175 659 1484 248 713 1687 345 770 1890 442 828 2065 568 882 2239 694 937 2384 844 983 2528 994 1030 0.4 849 111 662 1151 185 705 1452 260 747 1658 360 804 1863 460 861 2041 586 911 2218 713 962 2363 861 1006 2508 1009 1050 0.5 779 121 718 1094 198 754 1410 275 790 1626 374 838 1842 473 886 2020 601 936 2197 730 987 2342 876 1028 2487 1023 1070 0.6 - -- - -- - -- - -- - -- - -- 1368 289 830 1589 390 876 1810 492 921 1993 619 966 2176 746 1010 2316 895 1054 2456 1043 1099 0.7 - -- - -- - -- - -- - -- - -- 1325 303 868 1552 406 911 1778 509 954 1966 635 993 2154 761 1033 2295 908 1075 2435 1055 1117 0.8 - -- - -- - -- - -- - -- - -- 1261 321 920 1504 423 952 1746 524 984 1934 653 1024 2122 782 1064 2268 925 1100 2414 1067 1135 0.9 - -- - -- - -- - -- - -- - -- 1211 337 964 1462 437 988 1714 538 1012 1902 669 1053 2090 801 1094 2237 942 1127 2383 1084 1161 1.0 - -- - -- - -- - -- - -- - -- 1151 354 1013 1412 454 1029 1672 553 1045 1871 682 1078 2069 811 1112 2211. 955 1149 2352 1099 1185 1.1 - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 1629 566 1073 1828 698 1109 2027 830 1146 2174 971 1177 2321 1112 1208 1.2 - -- - -- - -- -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 1984 844 1175 2137 984 1202 2290 1124 1230 HORIZONTAL Extemal Static Press. ln. w.g. Percentage of Total Motor Torque 200 30% 40% 50% 60% 70% 80% 90% 100% Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM Cfm Watts RPM 0 1127 82 426 1367 141 504 1607 200 582 1806 296 644 2005 391 706 2167 495 764 2328 599 822 2463 749 872 2598 899 922 0.1 1071 86 476 1326 148 543 1580 210 610 1781 311 675 1981 411 740 2145 516 795 2309 620 849 2456 775 898 2602 931 947 0.2 1010 91 529 1268 160 598 1525 229 668 1735 332 724 1945 434 781 2117 537 828 2289 640 875 2438 795 921 2587 949 967 0.3 930 100 597 1214 169 647 1497 239 696 1707 345 755 1917 452 814 2093 556 857 2269 660 900 2417 817 948 2565 975 995 0.4 869 109 646 1156 184 699 1442 258 751 1665 364 798 1888 469 845 2066 577 889 2243 685 933 2393 842 978 2543 998 1022 0.5 813 119 689 1114 193 734 1414 267 778 1637 376 827 1860 485 876 2039 597 920 2217 709 963 2373 861 1002 2528 1013 1040 0.6 - -- - -- - -- - -- - -- - -- 1358 286 831 1595 394 868 1832 501 905 2012 616 949 2191 731 993 2349 882 1028 2506 1033 1064 0.7 - -- - -- - -- - -- - -- - -- 1330 296 857 1560 409 903 1789 523 949 1977 638 985 2164 753 1020 2324 902 1054 2484 1052 1088 0.8 - -- - -- - -- - -- - -- - -- 1275 315 908 1518 426 942 1761 536 977 1950 655 1011 2138 773 1046 2296 923 1081 2454 1073 1116 0.9 - -- - -- - -- - -- - -- - -- 1233 329 946 1483 439 975 1732 549 1004 1922 670 1037 2112 792 1071 2272 939 1104 2432 1087 1136 1.0 - -- - -- -- - - -- 1192 343 982 1441 455 1012 1690 567 1043 1881 692 1074 2072 818 1105 2237 960 1133 2402 1102 1161 1.1 - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 1662 578 1068 1854 706 1097 2046 833 1126 2206 975 1157 2365 1117 1188 1.2 - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 1994 861 1163 2165 993 1185 2336 1125 1206 BLOWER DATA - BELT DRIVE - 3 TON BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 -Any factory installed options air resistance (heat section, economizer, etc.). 2 -Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 39 for blower motors and drives and wet coil and options /accessory air resistance data. DOWNFLOW Air Volume (cfm) External Static ( in.w.g.) 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.9 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 700 453 0.07 523 0.11 596 0.14 679 0.17 762 0.18 828 0.21 878 0.24 927 0.26 979 0.29 1029 0.31 800 471 0.09 542 0.13 614 0.16 696 0.19 777 0.21 841 0.23 889 0.26 938 0.29 990 0.31 1042 0.34 900 493 0.11 563 0.15 634 0.19 715 0.21 793 0.23 854 0.26 902 0.29 950 0.32 1002 0.34 1054 0.36 1000 517 0.14 587 0.18 657 0.21 736 0.24 811 0.26 869 0.29 916 0.32 964 0.35 1015 0.37 1067 0.4 1100 544 0.17 613 0.21 683 0.24 759 0.27 831 0.3 886 0.32 931 0.36 978 0.38 1028 0.41 1078 0.43 1200 574 0.2 643 0.24 711 0.27 784 0.3 852 0.33 904 0.36 947 0.39 993 0.42 1042 0.45 1091 0.47 1300 608 0.24 676 0.28 743 0.31 812 0.34 875 0.37 923 0.4 964 0.44 1010 0.46 1057 0.49 1104 0.51 1400 645 0.28 711 0.31 776 0.35 842 0.38 898 0.41 942 0.44 983 0.48 1028 0.51 1074 0.53 1120 0.56 Air Volume (cfm) External Static (in.w.g.) 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1 9 2 0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 700 1078 0.33 1124 0.36 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8 0 0 1091 0.36 1137 0.39 1180 0.41 1221 0.44 1260 0.47 - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 900 1105 0.39 1150 0.42 1192 0.45 1232 0.47 1270 0.5 1307 0.53 1345 0.56 1382 0.59 1420 0.62 - - - - - - 1000 1117 0.42 1162 0.45 1203 0.48 1242 0.51 1279 0.54 1316 0.57 1353 0.6 1390 0.63 1427 0.66 1465 0.7 1100 1126 0.46 1171 0.49 1212 0.52 1251 0.56 1288 0.59 1325 0.62 1361 0.65 1397 0.68 1433 0.71 1470 0.75 1200 1137 0.5 1180 0.54 1222 0.57 1260 0.6 1298 0.64 1334 0.67 1369 0.7 1404 0.73 1440 0.77 1477 0.8 1300 1149 0.55 1191 0.58 1232 0.62 1270 0.65 1307 0.69 1343 0.72 1378 0.76 1413 0.79 1449 0.82 1486 0.86 1400 1163 0.6 1204 0.63 1243 0.67 1281 0.71 1317 0.74 1353 0.78 1388 0.82 1423 0.85 1459 0.89 1496 0.92 Energence. Packaged Gas / Electric 3 to 6 Ton / Page 31 BLOWER DATA - BELT DRIVE - 3 TON BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 -Any factory installed options air resistance (heat section, economizer, etc.). 2 -Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 39 for blower motors and drives and wet coil and options /accessory air resistance data. HORIZONTAL Air Volume (cfm) External Static (in.w.g.) 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.9 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 700 440 0.07 510 0.1 585 0.12 657 0.14 726 0.17 793 0.2 856 0.23 915 0.25 967 0.28 1016 0.31 800 456 0.08 526 0.11 600 0.14 672 0.16 739 0.19 804 0.22 866 0.25 923 0.28 975 0.31 1025 0.34 900 474 0.1 544 0.13 617 0.16 688 0.18 754 0.21 818 0.24 877 0.27 932 0.3 984 0.33 1034 0.36 1000 495 0.12 565 0.15 637 0.18 707 0.21 771 0.23 832 0.27 889 0.3 943 0.33 993 0.36 1043 0.39 1100 518 0.14 588 0.18 659 0.21 727 0.23 789 0.26 848 0.3 903 0.33 954 0.37 1003 0.4 1052 0.43 1200 544 0.17 613 0.21 682 0.24 748 0.27 809 0.29 866 0.33 918 0.37 967 0.4 1014 0.43 1062 0.46 1300 572 0.21 640 0.24 707 0.27 771 0.3 830 0.33 884 0.37 934 0.41 981 0.44 1027 0.47 1073 0.5 1400 602 0.24 669 0.28 733 0.31 795 0.34 851 0.37 903 0.41 950 0.45 995 0.49 1040 0.52 1086 0.55 Air Volume (cfm) External Static ( in.w.g.) 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 700 1065 0.33 8 0 0 1075 0.36 1122 0.39 1164 0.42 1203 0.45 1241 0.47 - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 900 1086 0.39 1133 0.42 1174 0.45 1213 0.48 1250 0.51 1286 0.54 1322 0.57 1357 0.6 1392 0.64 - - - - - - 1000 1094 0.43 1142 0.46 1183 0.49 1222 0.52 1259 0.55 1295 0.58 1330 0.62 1365 0.65 1400 0.68 1435 0.71 1100 1102 0.46 1148 0.49 1191 0.53 1230 0.56 1267 0.6 1303 0.63 1338 0.66 1373 0.69 1408 0.73 1444 0.76 1200 1110 0.5 1156 0.53 1198 0.57 1238 0.61 1275 0.64 1311 0.68 1346 0.71 1381 0.74 1416 0.78 1452 0.81 1300 1120 0.54 1164 0.58 1207 0.62 1246 0.65 1283 0.69 1319 0.73 1354 0.76 1389 0.79 1424 0.83 1460 0.86 1400 1131 0.59 1175 0.63 1216 0.67 1255 0.7 1292 0.74 1327 0.78 1362 0.81 1397 0.84 1432 0.88 1468 0.91 1 Energence° Packaged Gas / Electric 3 to 6 Ton / Page 32 BLOWER DATA - BELT DRIVE - 4 TON BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 - Any factory installed options air resistance (heat section, economizer, etc.). 2 -Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 39 for blower motors and drives and wet coil and options /accessory air resistance data. DOWNFLOW Air Volume (cfm) External Static (in.w.g.) 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.9 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 900 502 0.12 573 0.15 644 0.19 725 0.22 802 0.24 861 0.26 908 0.29 957 0.32 1009 0.34 1061 0.37 1000 528 0.14 598 0.18 668 0.22 747 0.24 821 0.27 877 0.3 923 0.33 971 0.35 1022 0.38 1074 0.4 1100 557 0.17 626 0.21 695 0.25 772 0.28 841 0.3 894 0.33 939 0.36 986 0.39 1037 0.41 1087 0.44 1200 589 0.21 657 0.25 725 0.28 798 0.31 864 0.33 913 0.37 956 0.4 1003 0.43 1052 0.45 1100 0.48 1300 625 0.25 692 0.28 759 0.32 827 0.34 887 0.37 933 0.41 975 0.44 1021 0.47 1068 0.49 1115 0.52 1400 665 0.29 730 0.32 794 0.35 857 0.38 911 0.42 953 0.45 995 0.49 1040 0.52 1086 0.54 1131 0.57 1500 706 0.33 768 0.36 829 0.39 886 0.43 934 0.46 974 0.5 1015 0.54 1060 0.56 1105 0.59 1149 0.62 1600 746 0.37 805 0.4 862 0.44 914 0.48 957 0.52 996 0.55 1037 0.59 1081 0.62 1126 0.64 1167 0.68 1700 784 0.42 840 0.45 893 0.49 940 0.53 980 0.57 1019 0.61 1060 0.64 1104 0.67 1147 0.7 1187 0.74 1800 821 0.47 874 0.51 923 0.55 967 0.59 1006 0.63 1044 0.67 1085 0.7 1128 0.73 1170 0.77 1208 0.82 1900 857 0.53 906 0.57 952 0.62 994 0.66 1032 0.7 1071 0.73 1112 0.76 1154 0.8 1194 0.85 1230 0.9 Air Volume (cfm) External Static (in.w.g.) 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 900 1111 0.39 1156 0.42 1197 0.45 1236 0.48 1275 0.51 1312 0.54 1349 0.56 1387 0.59 1424 0.62 - - - - - - 1000 1124 0.43 1168 0.46 1209 0.49 1247 0.52 1285 0.55 1322 0.58 1358 0.61 1395 0.64 1432 0.67 1470 0.7 1100 1134 0.47 1178 0.5 1219 0.53 1258 0.56 1295 0.6 1331 0.63 1367 0.66 1403 0.69 1439 0.72 1477 0.75 1200 1146 0.51 1189 0.54 1230 0.58 1268 0.61 1305 0.65 1341 0.68 1376 0.71 1411 0.74 1447 0.77 1485 0.81 1300 1159 0.55 1201 0.59 1241 0.63 1279 0.66 1315 0.7 1351 0.73 1386 0.77 1421 0.8 1457 0.83 1495 0.87 1400 1173 0.61 1214 0.64 1253 0.68 1290 0.72 1327 0.75 1362 0.79 1397 0.82 1432 0.86 1468 0.89 1506 0.93 1500 1189 0.66 1228 0.7 1266 0.74 1303 0.78 1339 0.81 1374 0.85 1409 0.89 1445 0.92 1481 0.96 1519 1 1600 1206 0.72 1244 0.76 1281 0.8 1317 0.84 1353 0.88 1388 0.92 1423 0.96 1459 1 1496 1.04 1535 1.08 1700 1224 0.79 1261 0.83 1298 0.87 1334 0.91 1369 0.95 1404 0.99 1440 1.03 1476 1.07 1513 1.12 1552 1.16 1800 1244 0.86 1280 0.91 1316 0.95 1352 0.99 1387 1.03 1422 1.07 1457 1.11 1494 1.16 1532 1.2 1570 1.24 1900 1265 0.95 1301 1 1336 1.04 1371 1.08 1406 1.12 1441 1.16 1477 1.2 1515 1.24 1553 1.29 1592 1.33 Energence• Packaged Gas / Electric 3 to 6 Ton / Page 33 BLOWER DATA - BELT DRIVE - 4 TON BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 -Any factory installed options air resistance (heat section, economizer, etc.). 2 - Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 39 for blower motors and drives and wet coil and options /accessory air resistance data. HORIZONTAL Air Volume (cfm) Extemal Static (in.w.g.) 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0 9 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 900 483 0.1 554 0.13 627 0.16 699 0.19 765 0.22 826 0.24 882 0.27 935 0.3 986 0.33 1039 0.36 1000 505 0.12 576 0.16 648 0.19 719 0.21 784 0.24 842 0.27 896 0.3 947 0.33 998 0.37 1050 0.4 1100 530 0.15 601 0.18 671 0.21 741 0.24 804 0.27 860 0.3 912 0.34 961 0.37 1010 0.4 1060 0.43 1200 558 0.18 627 0.22 696 0.25 764 0.28 824 0.3 878 0.34 928 0.37 975 0.41 1023 0.44 1072 0.47 1300 588 0.22 656 0.25 723 0.28 788 0.31 846 0.34 897 0.38 945 0.42 990 0.45 1037 0.48 1084 0.51 1400 621 0.25 687 0.29 752 0.32 814 0.35 868 0.38 916 0.42 962 0.46 1006 0.5 1052 0.53 1098 0.56 1500 655 0.29 719 0.33 781 0.36 839 0.39 890 0.43 936 0.47 979 0.51 1023 0.55 1068 0.58 1113 0.61 1600 690 0.33 751 0.37 810 0.4 865 0.44 912 0.48 955 0.52 997 0.56 1041 0.6 1086 0.63 1129 0.66 1700 725 0.38 784 0.41 839 0.45 891 0.49 935 0.53 975 0.58 1017 0.62 1060 0.65 1104 0.68 1147 0.72 1800 761 0.42 816 0.46 868 0.5 916 0.55 957 0.59 997 0.64 1038 0.68 1081 0.71 1124 0.74 1165 0.79 1900 795 0.48 848 0.52 897 0.56 942 0.61 981 0.66 1020 0.7 1060 0.74 1103 0.77 1145 0.81 1183 0.85 Air Volume (cfm) Extemal Static ( in.w.g.) 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 900 1091 0.4 1138 0.43 1180 0.46 1220 0.49 1257 0.53 1293 0.56 1329 0.59 1364 0.62 1400 0.65 1435 0.69 1000 1101 0.43 1149 0.46 1190 0.5 1229 0.53 1266 0.57 1302 0.6 1338 0.63 1373 0.66 1408 0.7 1444 0.73 1100 1110 0.46 1156 0.5 1199 0.54 1238 0.57 1275 0.61 1311 0.64 1346 0.67 1381 0.71 1416 0.74 1452 0.78 1200 1119 0.5 1165 0.54 1207 0.58 1247 0.62 1284 0.65 1319 0.69 1355 0.72 1389 0.75 1425 0.79 1460 0.82 1300 1130 0.55 1175 0.59 1216 0.63 1255 0.66 1292 0.7 1328 0.74 1363 0.77 1398 0.8 1433 0.84 1469 0.87 1400 1143 0.6 1186 0.63 1226 0.67 1265 0.71 1302 0.75 1337 0.79 1372 0.82 1406 0.85 1441 0.89 1477 0.93 1500 1156 0.65 1198 0.69 1237 0.73 1275 0.77 1311 0.8 1346 0.84 1381 0.88 1415 0.91 1450 0.95 1486 0.98 1600 1171 0.7 1211 0.74 1249 0.78 1286 0.82 1321 0.86 1356 0.9 1390 0.93 1425 0.97 1460 1.01 1496 1.05 1700 1186 0.76 1225 0.8 1262 0.84 1298 0.88 1333 0.92 1367 0.96 1401 1 1436 1.03 1471 1.07 1507 1.12 1800 1202 0.83 1240 0.87 1276 0.91 1311 0.95 1345 0.99 1380 1.03 1413 1.07 1448 1.11 1483 1.15 1520 1.19 1900 1220 0.9 1256 0.94 1291 0.99 1326 1.03 1360 1.07 1393 1.1 1427 1.14 1462 1.18 1497 1.22 1534 1.27 Energence° Packaged Gas / Electric 3 to 6 Ton / Page 34 BLOWER DATA - BELT DRIVE - 5 TON BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 - Any factory installed options air resistance (heat section, economizer, etc.). 2 -Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 39 for blower motors and drives and wet coil and options /accessory air resistance data. DOWNFLOW Air Volume (cfm) External Static ( In.w.g.) 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0 9 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1100 529 0.17 591 0.21 653 0.24 724 0.26 810 0.26 886 0.26 942 0.28 982 0.32 1022 0.36 1064 0.40 1200 553 0.20 615 0.24 677 0.27 747 0.30 829 0.30 902 0.30 955 0.33 994 0.36 1034 0.40 1075 0.44 1300 579 0.23 640 0.27 701 0.31 770 0.33 850 0.34 918 0.35 969 0.37 1007 0.41 1047 0.45 1088 0.49 1400 609 0.27 669 0.31 729 0.34 796 0.37 871 0.38 936 0.39 983 0.41 1022 0.45 1061 0.49 1102 0.53 1500 658 0.28 715 0.32 771 0.36 832 0.39 898 0.41 955 0.43 999 0.46 1037 0.50 1077 0.54 1117 0.58 1600 720 0.28 769 0.33 819 0.37 871 0.41 926 0.44 975 0.47 1016 0.51 1054 0.55 1093 0.60 1133 0.63 1700 779 0.30 822 0.35 864 0.39 908 0.44 953 0.48 995 0.52 1034 0.57 1072 0.61 1111 0.65 1150 0.69 1800 828 0.34 864 0.39 901 0.43 938 0.48 977 0.53 1015 0.58 1053 0.63 1091 0.67 1130 0.71 1169 0.75 1900 857 0.41 892 0.45 927 0.50 962 0.55 999 0.60 1036 0.65 1074 0.69 1112 0.73 1150 0.77 1188 0.81 2000 879 0.47 913 0.52 948 0.56 984 0.61 1020 0.67 1058 0.72 1096 0.76 1134 0.80 1172 0.84 1210 0.88 2100 900 0.53 935 0.58 970 0.63 1007 0.69 1044 0.74 1081 0.79 1119 0.84 1157 0.88 1195 0.91 1233 0.95 2200 922 0.60 958 0.65 994 0.71 1031 0.76 1068 0.82 1106 0.87 1143 0.91 1180 0.95 1218 0.99 1255 1.03 2300 947 0.67 983 0.73 1020 0.79 1057 0.85 1094 0.90 1131 0.95 1168 1.00 1205 1.03 1242 1.07 1277 1.13 2400 974 0.76 1010 0.82 1047 0.88 1084 0.94 1120 0.99 1157 1.04 1193 1.08 1230 1.12 1267 1.16 1300 1.23 Air Volume (cfm) External Static (in.w.g.) 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1100 1106 0.44 1151 0.47 1197 0.49 1238 0.52 1272 0.56 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 2 0 0 1117 0.48 1161 0.51 1206 0.53 1245 0.57 1278 0.60 1312 0.64 1346 0.67 1380 0.71 - - - - - - - - - - - - 1300 1129 0.52 1172 0.55 1216 0.58 1254 0.61 1287 0.65 1320 0.69 1354 0.72 1388 0.76 1421 0.79 1455 0.82 1400 1143 0.57 1185 0.60 1227 0.63 1264 0.66 1296 0.70 1329 0.74 1363 0.77 1397 0.81 1430 0.85 1464 0.88 1500 1157 0.62 1199 0.65 1239 0.68 1275 0.71 1306 0.75 1339 0.79 1373 0.83 1406 0.87 1440 0.90 1473 0.94 1600 1173 0.67 1214 0.70 1253 0.73 1288 0.77 1318 0.81 1351 0.85 1384 0.89 1417 0.93 1451 0.96 1484 1.00 1700 1190 0.72 1230 0.76 1268 0.79 1301 0.83 1331 0.87 1363 0.92 1396 0.95 1429 0.99 1462 1.03 1495 1.07 1800 1208 0.78 1247 0.82 1285 0.86 1317 0.90 1345 0.94 1377 0.98 1410 1.02 1442 1.06 1475 1.10 1508 1.14 1900 1227 0.85 1267 0.88 1303 0.92 1333 0.97 1360 1.02 1392 1.06 1424 1.10 1457 1.14 1489 1.18 1522 1.22 2000 1248 0.92 1286 0.96 1321 1.00 1350 1.05 1377 1.10 1409 1.14 1441 1.18 1473 1.22 1505 1.26 1537 1.30 2100 1269 1.00 1306 1.04 1339 1.09 1367 1.14 1395 1.19 1426 1.23 1458 1.27 1490 1.31 1522 1.35 1554 1.39 2200 1290 1.09 1324 1.14 1356 1.19 1385 1.24 1413 1.28 1444 1.32 1476 1.36 1508 1.41 1540 1.45 1572 1.49 2300 1310 1.20 1343 1.26 1374 1.30 1403 1.34 1432 1.38 1464 1.42 1495 1.46 1527 1.51 1559 1.55 1591 1.59 2400 1332 1.31 1364 1.37 1394 1.41 1423 1.45 1453 1.48 1484 1.53 1516 1.57 1547 1.61 1579 1.65 1612 1.70 Energence° Packaged Gas / Electric 3 to 6 Ton / Page 35 BLOWER DATA - BELT DRIVE - 5 TON BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 -Any factory installed options air resistance (heat section, economizer, etc.). 2 -Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 39 for blower motors and drives and wet coil and options /accessory air resistance data. HORIZONTAL Air Volume (cfm) External Static (in.w.g.) 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0 9 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1100 503 0.14 569 0.17 636 0.20 703 0.23 769 0.26 842 0.28 909 0.30 964 0.33 1008 0.36 1049 0.40 1200 525 0.16 590 0.20 657 0.23 722 0.26 787 0.29 857 0.31 921 0.34 974 0.37 1016 0.40 1056 0.43 1300 548 0.19 613 0.23 679 0.26 743 0.29 806 0.32 873 0.35 934 0.37 984 0.41 1026 0.44 1065 0.47 1400 574 0.22 638 0.26 702 0.30 765 0.33 827 0.36 891 0.39 949 0.41 996 0.45 1037 0.48 1076 0.51 1500 609 0.25 671 0.29 733 0.33 793 0.36 851 0.39 911 0.42 965 0.46 1010 0.49 1049 0.53 1088 0.56 1600 654 0.28 712 0.32 769 0.36 825 0.39 879 0.43 933 0.47 982 0.50 1024 0.54 1063 0.58 1101 0.61 1700 703 0.31 756 0.35 807 0.39 858 0.43 906 0.47 955 0.51 999 0.55 1039 0.59 1078 0.63 1117 0.66 1800 752 0.34 798 0.38 844 0.43 889 0.48 933 0.52 977 0.57 1017 0.61 1056 0.65 1094 0.68 1133 0.72 1900 796 0.38 837 0.43 878 0.48 918 0.53 958 0.58 997 0.62 1036 0.67 1074 0.71 1112 0.74 1151 0.77 2000 833 0.43 870 0.48 907 0.54 943 0.59 980 0.64 1018 0.69 1055 0.73 1093 0.77 1131 0.80 1170 0.83 2100 864 0.50 897 0.55 931 0.60 966 0.65 1002 0.71 1038 0.76 1075 0.80 1113 0.83 1151 0.87 1189 0.90 2200 887 0.57 920 0.62 953 0.67 988 1 0.73 1024 0.78 1060 0.83 1097 0.87 1135 0.90 1173 0.94 1210 0.98 2300 909 0.64 942 0.70 976 0.75 1011 0.81 1046 0.86 1083 0.91 1120 0.95 1157 0.98 1195 1.02 1231 1.06 2400 931 0.72 965 0.78 999 0.83 1035 0.89 1071 0.94 1108 0.99 1144 1.03 1181 1.07 1217 1.10 1252 1.15 Air Volume (cfm) External Static (in.w.g.) 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1100 1090 0.42 1132 0.45 1175 0.47 1216 0.50 1257 0.53 1296 0.56 1334 0.59 1370 0.62 1405 0.65 1439 0.69 1200 1097 0.46 1139 0.49 1181 0.51 1222 0.54 1263 0.57 1301 0.60 1338 0.63 1374 0.67 1409 0.70 1443 0.74 1300 1106 0.50 1147 0.53 1189 0.55 1230 0.58 1270 0.61 1307 0.65 1344 0.68 1379 0.72 1414 0.75 1447 0.79 1400 1116 0.54 1157 0.57 1198 0.60 1239 0.63 1278 0.66 1315 0.70 1351 0.74 1385 0.77 1419 0.81 1452 0.85 1500 1128 0.59 1168 0.62 1209 0.64 1249 0.68 1287 0.71 1323 0.75 1358 0.79 1393 0.83 1426 0.87 1458 0.91 1600 1141 0.64 1181 0.67 1222 0.70 1261 0.73 1298 0.77 1333 0.81 1367 0.85 1401 0.89 1433 0.93 1465 0.97 1700 1156 0.69 1196 0.72 1235 0.75 1273 0.79 1309 0.83 1344 0.87 1377 0.91 1410 0.96 1442 1.00 1473 1.04 1800 1172 0.75 1211 0.78 1250 0.81 1287 0.85 1322 0.90 1355 0.94 1388 0.98 1420 1.02 1451 1.07 1482 1.11 1900 1190 0.81 1228 0.84 1265 0.88 1301 0.92 1335 0.97 1367 1.01 1399 1.05 1431 1.10 1462 1.14 1492 1.18 2000 1208 0.87 1245 0.91 1281 0.96 1316 1.00 1349 1.04 1380 1.09 1412 1.13 1443 1.18 1473 1.22 1503 1.26 2100 1227 0.94 1263 0.99 1298 1.04 1331 1.08 1363 1.13 1394 1.17 1425 1.22 1455 1.26 1485 1.31 1515 1.35 2200 1246 1.02 1281 1.07 1315 1.12 1347 1.17 1379 1.22 1409 1.26 1439 1.31 1469 1.36 1499 1.40 1529 1.45 2300 1266 1.11 1300 1.16 1333 1.22 1364 1.27 1395 1.32 1424 1.36 1454 1.41 1484 1.46 1513 1.50 1543 1.55 2400 1286 1.20 1319 1.26 1351 1.32 1382 1.38 1411 1.43 1440 1.48 1470 1.52 1499 1.57 1528 1.61 1558 1.66 Energence° Packaged Gas /Electric 3 to 6 Ton / Page 36 BLOWER DATA - BELT DRIVE - 6 TON BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 -Any factory installed options air resistance (heat section, economizer, etc.). 2 -Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 39 for blower motors and drives and wet coil and options/accessory air resistance data. DOWNFLOW Air Volume (cfm) External Static ( in.w.g.) 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.9 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1900 510 0.45 544 0.5 579 0.55 614 0.6 649 0.65 684 0.7 718 0.74 752 0.79 784 0.83 812 0.88 2000 526 0.49 560 0.55 595 0.6 629 0.65 663 0.7 697 0.75 730 0.79 763 0.84 794 0.88 820 0.93 2100 542 0.54 576 0.59 610 0.65 644 0.7 678 0.75 711 0.8 743 0.84 775 0.89 804 0.94 830 0.98 2200 560 0.59 593 0.64 627 0.7 660 0.75 693 0.8 725 0.85 757 0.9 787 0.94 814 0.99 840 1.03 2300 578 0.64 610 0.7 644 0.75 676 0.81 709 0.86 740 0.91 770 0.95 799 1 826 1.05 851 1.09 2400 597 0.7 629 0.75 661 0.81 693 0.86 725 0.91 755 0.96 784 1.01 812 1.06 838 1.11 862 1.15 2500 617 0.76 648 0.81 679 0.87 710 0.92 741 0.97 770 1.03 799 1.08 825 1.13 850 1.17 875 1.22 2600 637 0.82 667 0.87 698 0.93 728 0.98 758 1.04 786 1.09 814 1.15 839 1.2 864 1.24 887 1.28 2700 658 0.88 687 0.94 717 1 746 1.05 775 1.11 802 1.16 829 1.22 853 1.27 877 1.31 901 1.36 2800 679 0.95 708 1.01 736 1.07 764 1.12 792 1.18 819 1.24 844 1.3 868 1.35 892 1.39 915 1.43 2900 701 1.02 728 1.08 756 1.14 783 1.2 809 1.26 835 1.32 860 1.38 884 1.43 907 1.47 930 1.52 Air Volume (cfm) External Static (in.w.g.) 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1900 837 0.92 861 0.96 886 1 913 1.04 939 1.07 966 1.11 992 1.16 1017 1.21 1041 1.27 1065 1.33 2000 845 0.97 870 1.01 895 1.05 921 1.09 948 1.12 974 1.17 999 1.22 1023 1.27 1047 1.33 1070 1.39 2100 855 1.02 879 1.06 904 1.1 930 1.14 956 1.18 982 1.22 1006 1.28 1030 1.34 1053 1.4 1075 1.46 2200 865 1.08 889 1.12 914 1.15 940 1.19 966 1.24 990 1.29 1014 1.34 1037 1.41 1059 1.47 1081 1.54 2300 875 1.13 900 1.17 925 1.21 951 1.25 976 1.3 999 1.35 1022 1.41 1044 1.48 1066 1.55 1087 1.62 2400 887 1.19 912 1.23 936 1.27 961 1.32 986 1.37 1009 1.43 1031 1.49 1052 1.57 1073 1.64 1094 1.71 2500 899 1.25 923 1.29 948 1.34 973 1.39 996 1.44 1018 1.51 1039 1.58 1060 1.65 1080 1.73 1101 1.8 2600 912 1.32 936 1.36 960 1.41 984 1.46 1007 1.52 1028 1.59 1049 1.67 1069 1.75 1089 1.82 1109 1.89 2700 925 1.4 949 1.44 973 1.49 996 1.55 1018 1.61 1038 1.69 1058 1.76 1078 1.84 1098 1.92 1118 1.99 2800 939 1.47 962 1.52 985 1.57 1008 1.64 1029 1.71 1049 1.79 1069 1.87 1088 1.94 1107 2.02 1127 2.09 2900 953 1.56 976 1.61 998 1.67 1020 1.73 1041 1.81 1060 1.89 1079 1.98 1098 2.06 1117 2.13 1137 2.21 Energencem Packaged Gas / Electric 3 to 6 Ton / Page 37 BLOWER DATA - BELT DRIVE - 6 TON BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 -Any factory installed options air resistance (heat section, economizer, etc.). 2 -Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 39 for blower motors and drives and wet coil and options /accessory air resistance data. HORIZONTAL Air Volume (cfm) External Static (in.w.g.) 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.9 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1900 485 0.55 516 0.57 549 0.59 583 0.62 618 0.65 654 0.69 689 0.73 724 0.77 758 0.82 790 0.86 2000 499 0.59 531 0.61 563 0.63 597 0.66 631 0.7 666 0.73 701 0.77 734 0.82 767 0.86 798 0.91 2100 514 0.63 546 0.65 578 0.68 611 0.71 645 0.74 679 0.78 712 0.82 745 0.86 777 0.91 806 0.96 2200 530 0.68 562 0.7 594 0.73 627 0.76 660 0.79 693 0.83 725 0.87 757 0.92 787 0.96 816 1.01 2300 548 0.73 579 0.75 610 0.78 643 0.81 675 0.85 707 0.88 738 0.93 769 0.97 798 1.02 826 1.06 2400 566 0.78 596 0.81 628 0.84 659 0.87 691 0.9 722 0.94 752 0.98 782 1.03 810 1.08 837 1.12 2500 585 0.84 615 0.86 645 0.9 676 0.93 707 0.96 737 1 767 1.05 795 1.09 822 1.14 848 1.19 2600 604 0.9 634 0.93 664 0.96 694 0.99 724 1.03 753 1.07 781 1.11 809 1.15 835 1.2 861 1.25 2700 624 0.96 653 0.99 682 1.02 712 1.06 741 1.09 769 1.13 796 1.18 823 1.22 849 1.27 873 1.32 2800 645 1.02 673 1.05 701 1.09 730 1.12 758 1.16 785 1.2 812 1.25 838 1.29 862 1.34 886 1.39 2900 665 1.09 693 1.12 721 1.16 748 1.19 775 1.23 802 1.27 827 1.32 852 1.36 877 1.41 900 1.46 Air Volume (cfm) Extemal Static (in.w.g.) 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1900 819 0.9 846 0.94 871 0.98 897 1.02 922 1.05 948 1.09 974 1.13 999 1.18 1025 1.23 1050 1.28 2000 826 0.95 852 0.99 877 1.03 902 1.06 928 1.1 953 1.14 979 1.18 1004 1.23 1029 1.28 1054 1.34 2100 834 1 859 1.04 884 1.08 909 1.12 934 1.15 960 1.2 985 1.24 1010 1.29 1034 1.35 1058 1.4 2200 842 1.05 868 1.1 892 1.13 917 1.17 942 1.21 967 1.26 992 1.3 1016 1.36 1040 1.41 1063 1.47 2300 852 1.11 877 1.15 901 1.19 926 1.23 950 1.27 975 1.32 999 1.37 1023 1.42 1046 1.48 1069 1.54 2400 862 1.17 887 1.21 911 1.25 935 1.3 959 1.34 983 1.39 1007 1.44 1030 1.5 1053 1.56 1075 1.62 2500 873 1.23 897 1.28 921 1.32 945 1.36 969 1.41 992 1.46 1016 1.52 1038 1.58 1060 1.64 1082 1.7 2600 885 1.3 909 1.34 932 1.39 955 1.43 979 1.49 1002 1.54 1025 1.6 1047 1.66 1069 1.73 1090 1.79 2700 897 1.37 920 1.41 944 1.46 967 1.51 990 1.57 1012 1.62 1034 1.69 1056 1.75 1077 1.82 1098 1.89 2800 910 1.44 933 1.49 955 1.54 978 1.6 1001 1.65 1023 1.72 1044 1.78 1066 1.85 1086 1.92 1107 1.99 2900 923 1.52 945 1.57 968 1.63 990 1.68 1012 1.75 1034 1.81 1055 1.88 1076 1.95 1096 2.02 1116 2.09 Energence° Packaged Gas /Electric 3 to 6 Ton / Page 38 BLOWER DATA BELT DRIVE KIT SPECIFICATIONS - 036 -060 Model No. Motor HP No. of Speeds Drive Kits and RPM Range Nominal Maximum A01 A02 A03 A05 A06 A07 036 0.75 0.86 2 1ow449 -673 high 673 -1010 - - - - - - - -- - - - - -- 1 1.15 2 0.02 - - - - - - low 598 -897 high 897 -1346 - - - - - - 048 0.75 0.86 2 - - - low497 -673 high 745 -1117 - - - - - - - - - - -- 2 2.3 2 - -- - -- - -- - -- 1ow714 -953 high 1071 -1429 - -- 060 1 1.15 2 - - - - - - low 555 -833 high 833 -1250 - - - - - - - - - 2 2.3 2 - -- - -- - -- - -- - -- low 808-1032 high 1212 -1548 BELT DRIVE KIT SPECIFICATIONS - 072 Model No. Motor HP No. of Speeds - - - Nominal Maximum AA01 AA02 AA03 072 1 1.15 1 522 -784 - - - - - - 2 2.3 1 - - - 632 -875 798 -1105 FACTORY INSTALLED OPTIONS /FIELD INSTALLED ACCESSORY AIR RESISTANCE - in. w.g. Air Volume cfm Wet Indoor Coil 036 048 060, 072 Humiditrol Dehumidification Coil Gas Heating Medium High Heat Heat Economizer Filters MERV8 MERV 13 036 -048 MODELS 800 0.01 0.01 - - - 0.00 0.02 0.02 0.04 0.04 0.05 1000 0.02 0.02 - - - 0.00 0.02 0.02 0.04 0.04 0.07 1200 0.03 0.04 - - - 0.01 0.02 0.02 0.04 0.04 0.07 1400 0.04 ' 0.05 - - - 0.02 0.02 0.03 0.04 0.04 0.07 1600 0.05 0.06 - - - 0.03 0.03 0.04 0.04 0.04 0.07 1800 0.06 0.07 - - - 0.04 0.04 0.05 0.05 0.04 0.07 2000 0.08 0.09 - - - 0.04 0.04 0.06 0.05 0.05 0.08 060 -072 MODELS 1000 - - - - - - 0.02 0.00 0.02 0.02 0.04 0.03 0.05 1200 - - - - - - 0.04 0.00 0.02 0.02 0.04 0.03 0.07 1400 - - - - - - 0.05 0.01 0.02 0.03 0.04 0.04 0.07 1600 - - - - - - 0.07 0.02 0.03 0.04 0.04 0.04 0.07 1800 - - - - - - 0.08 0.02 0.03 0.05 0.05 0.05 0.07 2000 - - - - - - 0.10 0.03 0.04 0.06 0.05 0.05 0.07 2200 - - - - - - 0.11 0.04 0.04 0.07 0.05 0.05 0.08 2400 - - - - - - 0.13 0.04 0.05 0.08 0.05 0.05 0.08 2600 - - - - - - 0.15 0.05 0.05 0.09 0.06 0.05 0.08 2800 - - - - - - 0.16 0.05 0.06 0.10 0.06 0.05 0.08 3000 - - - - - - 0.18 0.06 0.07 0.11 0.06 0.05 0.08 POWER EXHAUST FAN PERFORMANCE Return Air System Static Pressure in. w.g. Air Volume Exhausted cfm Return Air System Static Pressure in. w.g. Air Volume Exhausted cfm 036 -048 MODELS 060 -072 MODELS 0.00 2000 0.00 3175 0.05 1990 0.05 2955 0.10 1924 0.10 2685 0.15 1810 0.15 2410 0.20 1664 0.20 2165 0.25 1507 0.25 1920 0.30 1350 0.30 1420 0.35 1210 0.35 1200 Energence° Packaged Gas / Electric 3 to 6 Ton / Page 39 BLOWER DATA CEILING DIFFUSERS AIR RESISTANCE (in. w.g.) Air Volume cfm RTD9 -65 Step -Down Diffuser FD9 -65 Flush Diffuser RTD11 -95 Step -Down Diffuser' FD11 -95 Flush Diffuser 2 Ends Open 1 Side & 2 Ends Open All Ends & Sides Open 2 Ends Open 1 Side & 2 Ends Open All Ends & Sides Open 800 0.15 0.13 0.11 0.11 - - - - - - - - - - -- 1000 0.19 0.16 0.14 0.14 - - - - - - - - - - -- 1200 0.25 0.20 0.17 0.17 - - - - - - - - - - -- 1400 0.33 0.26 0.20 0.20 - - - - - - - - - - -- 1600 0.43 0.32 0.20 0.24 - -- - - - - - - - -- 1800 0.56 0.40 0.30 0.30 0.13 0.11 0.09 0.09 2000 0.73 0.50 0.36 0.36 0.15 0.13 0.11 0.10 2200 0.95 0.63 0.44 0.44 0.18 0.15 0.12 0.12 2400 - - - - - - - - - - - - - 0.21 0.18 0.15 0.14 2600 - - - - - - - - - - - - - 0.24 0.21 0.18 0.17 2800 - - - - - - - - - - - - - 0.27 0.24 0.21 0.20 3000 - - - - - - - - - - - - - 0.32 0.29 0.25 0.25 CEILING DIFFUSER AIR THROW DATA Air Volume - cfm ' Effective Throw - ft. Model No. RTD9 -65 FD9-65 800 10 -17 14 -18 1000 10 -17 15 -20 1200 11 -18 16 -22 1400 12 -19 17 -24 1600 12 -20 18 -25 1800 13 - 21 20 - 28 2000 14 -23 21 -29 2200 16 - 25 22 - 30 Model No. RTD11 -95 FD11 -95 2600 24 - 29 19 - 24 2800 25 -30 20 -28 3000 27 -33 21 -29 ' Effective throw based on terminal velocities of 75 ft. per minute. Energence® Packaged Gas / Electric 3 to 6 Ton / Page 40 ELECTRICAL DATA 3 TON HIGH EFFICIENCY (R -410A) 3 TON LGHO36H4 ' Voltage - 60hz 208/230V -1 Ph 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph Compressor Rated Load Amps 16.7 11.2 4.5 3.7 Locked Rotor Amps 82 58 29 22.5 Outdoor Fan Full Load Amps Motor 4.1 4.1 2.1 1.6 Power Exhaust Full Load Amps (1) 0.33 HP 2.4 2.4 1.3 1 Service Outlet 115V GFI (amps) 15 15 15 15 Indoor Blower Horsepower 0.5 0.5 0.5 0.5 Motor Full Load Amps 4.3 4.3 2.2 1.7 2 Maximum Unit Only 45 30 15 15 Overcurrent With (1) 0.33 HP Protection Power Exhaust 45 35 15 15 ' Minimum Unit Only 30 23 10 8 Circuit With (1) 0.33 HP Ampacity Power Exhaust 32 25 12 9 ' Extremes of operating range are plus and minus 10% of line voltage. ' HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 3 TON STANDARD EFFICIENCY (R-410A) LGHO36S4 ' Voltage - 60hz 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph Compressor Rated Load Amps 11.2 4.5 3.7 Locked Rotor Amps 58 29 22.5 Outdoor Fan Full Load Amps Motor 0.9 0.6 0.5 Power Exhaust Full Load Amps (1) 0.33 HP 2.4 1.3 1 Service Outlet 115V GFI (amps) 15 15 15 Indoor Blower Horsepower 0.75 1 0.75 1 0.75 1 Motor Full Load Amps 3.5 4.6 1.6 2.1 1.3 1.7 2 Maximum Unit Only 25 30 15 15 15 15 Overcurrent With (1) 0.33 HP Protection Power Exhaust 30 30 15 15 15 15 ' Minimum Unit Only 19 20 8 9 7 7 Circuit With (1) 0.33 HP Ampacity Power Exhaust 21 22 10 10 8 8 ' Extremes of operating range are plus and minus 10% of line voltage. 2 HACR type breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Energence• Packaged Gas / Electric 3 to 6 Ton / Page 41 ELECTRICAL DATA 4 TON HIGH EFFICIENCY (R -410A) 4 TON LGHO48H4 ' Voltage - 60hz 208/230V -1 Ph 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph Compressor Rated Load Amps 21.2 13.5 6.4 5 Locked Rotor Amps 96 88 41 37.8 Outdoor Fan Full Load Amps Motor 4.1 4.1 2.1 1.6 Power Exhaust Full Load Amps (1) 0.33 HP 2.4 2.4 1.3 1 Service Outlet 115V GFI (amps) 15 15 15 15 Indoor Blower Horsepower 0.75 0.75 0.75 0.75 Motor Full Load Amps 6.1 6.1 3.1 2.4 2 Maximum Unit Only 50 40 15 15 Overcurrent With (1) 0.33 HP Protection Power Exhaust 60 40 20 15 3 Minimum Unit Only 37 28 14 11 Circuit With (1) 0.33 HP Ampacity Power Exhaust 40 30 15 12 ' Extremes of operating range are plus and minus 10% of line voltage. ' HACR type breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 TON STANDARD EFFICIENCY (R -410A) LGHO48S4 ' Voltage - 60hz 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph Compressor Rated Load Amps 13.5 6.4 5 Locked Rotor Amps 88 41 37.8 Outdoor Fan Full Load Amps Motor 1.7 1.1 0.7 Power Exhaust Full Load Amps (1) 0.33 HP 2.4 1.3 1 Service Outlet 115V GFI (amps) 15 15 15 Indoor Blower Horsepower 0.75 2 0.75 2 0.75 2 Motor Full Load Amps 3.5 7.5 1.6 3.4 1.3 2.7 2 Maximum Unit Only 35 35 15 15 15 15 Overcurrent With (1) 0.33 HP Protection Power Exhaust 35 40 15 20 15 15 3 Minimum Unit Only 23 27 11 13 9 10 Circuit With (1) 0.33 HP Ampacity Power Exhaust 25 29 12 14 10 11 ' Extremes of operating range are plus and minus 10% of line voltage. ' HACR type breaker or fuse. ' Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Energence° Packaged Gas / Electric 3 to 6 Ton / Page 42 ELECTRICAL DATA 5 TON HIGH EFFICIENCY (R -410A) 5 TON LGH060H4 ' Voltage - 60hz 208/230V -1 Ph 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph Compressor Rated Load Amps 25.6 17.6 9 7.4 Locked Rotor Amps 118 135 62 50 Outdoor Fan Full Load Amps Motor 4.1 4.1 2.1 1.6 Power Exhaust Full Load Amps (1) 0.33 HP 2.4 2.4 1.3 1 Service Outlet 115V GFI (amps) 15 15 15 15 Indoor Blower Horsepower 1 1 1 1 Motor Full Load Amps 7.4 7.4 3.7 3 2 Maximum Unit Only 60 50 25 20 Overcurrent With (1) 0.33 HP Protection Power Exhaust 70 50 25 20 3 Minimum Unit Only 44 34 18 14 Circuit With (1) 0.33 HP Ampacity Power Exhaust 46 36 19 15 ' Extremes of operating range are plus and minus 10% of line voltage. = HACR type breaker or fuse. ' Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 5 TON STANDARD EFFICIENCY (R-410A) LGHO6OS4 1 Voltage - 60hz 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph Compressor Rated Load Amps 17.6 9 7.4 Locked Rotor Amps 135 62 50 Outdoor Fan Full Load Amps Motor 2.4 1.3 1 Power Exhaust Full Load Amps (1) 0.33 HP 2.4 1.3 1 Service Outlet 115V GFI (amps) 15 15 15 Indoor Blower Horsepower 1 2 1 2 1 2 Motor Full Load Amps 4.6 7.5 2.1 3.4 1.7 2.7 2 Maximum Unit Only 45 45 20 20 15 20 Overcurrent With (1) 0.33 HP Protection Power Exhaust 45 50 20 25 20 20 Minimum Unit Only 29 32 15 16 12 13 Circuit With (1) 0.33 HP Ampacity Power Exhaust 32 35 16 18 13 14 ' Extremes of operating range are plus and minus 10% of line voltage. 2 HACR type breaker or fuse. ' Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Energence• Packaged Gas / Electric 3 to 6 Ton / Page 43 ELECTRICAL DATA 6 TON HIGH EFFICIENCY (R -410A) 6 TON LGHO72H4 ' Voltage - 60hz 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph Compressor Rated Load Amps 19 9.7 7.4 Locked Rotor Amps 123 62 50 Outdoor Fan Full Load Amps Motor 2.4 1.3 1 Power Exhaust Full Load Amps (1) 0.33 HP 2.4 1.3 1 Service Outlet 115V GFI (amps) 15 15 15 Indoor Blower Horsepower 1 2 1 2 1 2 Motor Full Load Amps 4.6 7.5 2.1 3.4 1.7 2.7 2 Maximum Unit Only 45 50 25 25 15 20 Overcurrent With (1) 0.33 HP Protection Power Exhaust 50 50 25 25 20 20 3 Minimum Unit Only 31 34 16 17 12 13 Circuit With (1) 0.33 HP Ampacity Power Exhaust 34 37 17 19 13 14 ' Extremes of operating range are plus and minus 10% of line voltage. HACR type breaker or fuse. J Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Energence® Packaged Gas / Electric 3 to 6 Ton / Page 44 OPTIONAL CONVENTIONAL TEMPERATURE CONTROL SYSTEMS - FIELD INSTALLED COMMERCIAL TOUCHSCREEN THERMOSTAT Intuitive Touchscreen Interface - Two Stage Heating / Two Stage Cooling Conventional or Heat Pump - Seven Day Programmable - Four Time Periods/ Day - Economizer Output - Title 24 Compliant - ENERGY STAR® Qualified - Backlit Display - Automatic Changeover Sensors For Touchscreen Thermostat COSTATO2AE1L (14W81) — — - -- ' Remote non - adjustable wall mount 20k temperature sensor COSNZN01AE2- (47W36) ' Remote non - adjustable wall mount 10k averaging temperature sensor COSNZN73AE1- (47W37) ' Remote non - adjustable duct mount temperature sensor COSNDCOOAEI- (19L22) Outdoor temperature sensor COSNSRO3AE1- (X4148) Accessories For Touchscreen Thermostat Locking cover (clear) COMISC15AE1- (39P21) ENERGY STAR ' Remote sensors for COSTATO2AE1 L can be applied in the following combinations: (1) COSNZNO1AE1 -, (2) COSNZN73AE1 -, (2) COSNZNO1AE1- and (1) COSNZN73AE1 -, (4) COSNZNO1AE1 -, (3) COSNZNO1AE1- and (2) COSNZN73AE1. DIGITAL NON - PROGRAMMABLE THERMOSTATS Intuitive Interface - Automatic Changeover - Simple Up and Down Temperature Control I Two -stage heating / cooling conventional systems COSTAT1OAE1 L (13K98) Sensor For Digital Non - Programmable Thermostats Above Remote wall mounted temperature sensor COSNZNOOAE1- (26K57) Intuitive Interface - Automatic Changeover - Backlit Display - Simple Up and Down Temperature Control One -stage heating / cooling conventional systems COSTAT12AE1L (51M32) Sensor For Digital Non - Programmable Thermostats Above Outdoor temperature sensor COSNSRO4AE1- (X2658) Accessories For Digital Non - Programmable Thermostats Above Optional wall mounting plate COMISC17AE1- (X2659) OUTDOOR SOUND DATA Octave Band Sound Power Levels dBA, re 10-'2 Watts ' Unit Center Frequency - HZ Model No. 125 250 500 1000 2000 4000 8000 ' Sound Rating Number (dB) 036, 048 63 66 70 71 68 62 53 75 060, 072 67 72 77 76 73 68 61 82 NOTE - the octave sound power data does not indude tonal correction. ' Tested according to AHRI Standard 270-95 test conditions. Energence° Packaged Gas / Electric 3 to 6 Ton / Page 45 WEIGHT DATA Unit Model Number Net Shipping Base Max. Base Max, lbs. kg lbs. kg lbs. kg lbs. kg `1`01,11, 8' 13 257 762 346 629 285 823 373 kLG,H048 a— 98 _,a, 271 806 366 659 299 867 393 'ware ".ar' < "` 68 • 311 913 414 746 338 974 442 LGH072 762 346 960 436 823 373 1021 463 Base Unit - The unit with low fi e heat exchange NO OPTIONS. Max. Unit - The unit with ALL OPTIONS Installed. (High Input Heat Exchanger, Humiditrol, Economizer, Power Exhaust Fans, Controls OPTIONS / ACCESSORIES Model No Shipping Weight lbs. 1 kg. ECONOMIZER / OUTDOOR AIR / EXHAUST Economizer Economizer, Includes Outdoor Air Hood and Barometric Relief Dampers with Hood Outdoor Air Dampers Outdoor Air Damper Motorized Kit E1 ECON30A -1- E1 ECON3OAT1- 123 '56 142 65 Damper Section Manual EIDAMP21A -1- ElDAMP21AT1- EIDAMP11A-1- El DAMP11AT1- 25 29 18 22 12 14 9 11 Power Exhaust Standard Static ElPWRE1OA El PWRE1 OAT 35 17 39 19 GAS HEAT Medium Heat (adder over standard heat) High Heat (adder over standard heat) 8 4 19 9 PACKAGING LTL Packaging (less than truck Toad) 036-048 060 -072 60 27 65 29 ROOF CURBS - DOWNFLOW Clip Curb 8 in. height 14 in. height 18 in. height 24 in. height Standard T1CURB23AN1 T1CURB20AN1 T1 CURB21AN1 TICURB22AN1 78 96 108 126 57 14 in. height Hinged 8 in. height 18 in. height 24 in. height TICURB10AN1 96 44 T1CURB30AN1 T1 CURB32AN1 T1CURB33AN1 78 108 126 35 49 57 CEILING DIFFUSERS Step -Down Flush Transitions RTD9 -65 RTD11 -95 FD9-65 FD11 -95 T1TRAN10AN1 T1TRAN2ON -1 67 88 37 75 22 21 30 40 17 34 10 10 HUMIDITROL® DEHUMIDIFICATION SYSTEM Humiditrol 036 -048 060 -072 27 12 30 14 Energencee Packaged Gas / Electric 3 to 6 Ton / Page 46 UNIT CLEARANCES - INCHES (MM) OUT OORR A 11(11/( //T C AIR B in. mm u mm in. mm in. l 1 Unit Clearance A B C D To Clearance in. mm in. mm in. mm in. mm Service Clearance 48 1219 36 914 36 934 36 914 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. ' Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Energencee Packaged Gas / Electric 3 to 6 Ton / Page 47 DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm LGH036 Base Unit 98 45 119 54 192 87 158 72 38.5 978 18 457 LGH036 Max. Unit 137 62 155 70 250 113 221 100 40 1016 18 457 LGH048 Base Unit 104 47 126 57 202 92 167 76 38.5 978 18 457 LGH048 Max. Unit 145 66 164 74 264 120 233 106 40 1016 18 457 LGH060 Base Unit 118 54 144 65 232 105 191 87 38.5 978 18 457 LGH060 Max. Unit 164 75 186 84 299 136 264 120 40 1016 18 457 LGH072 Base Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 LGH072 Max. Unit 173 78 195 89 314 143 278 126 40 1016 18 457 Base Unit - The unit with NO INTERNAL OPTIONS. Max. Unit - The unit with ALL INTERNAL OPTIONS Installed. (Economizer, Standard Static Power Exhaust Fans, Controls, etc.). Does not include accessories external to unit or high static power exhaust. 5-5/8 (143 (279) 1(4 3) (457) 45 (1143) t5) (25) 100 1 1 1 1 (D01 47 (1192) el (' BASE END VIEW AA 7 (178) 29 (737) 47 (1192) BASE 2 0 s 3- LIFTING HOL Energencee Packaged Gas / Electric 3 to 6 Ton / Page 48 (For rigging) BOTTOM RETURN AIR OPENING BOTTOM SUPPLY AIR OPENING CENTER OF GRAVITY 5 (102) 6-5/8 168 FF 9-1/2 (241) BB DD I I CC — EE 26-1/2 (673) BOTTOM BOTTOM POWER AND CONDENSATE OUTLET GAS ENTRY TOP VIEW (Base) 3 X 8 (76 X 203) SIDE VIEW 11 1 (25) 19-10) 18-3/8 (279) r2(51) (495) (467) !MITI 83-1/4 (2115) V i 3 3 Zi p 4 t � IIIIII CONDENSATE OUTLET (EITHER SIDE) GAS INLET FLUENENT OUTLET ® 0 ELECTRICAL INLET GAS OUTLET FOR BOTTOM GAPIPING i ..........=......=. O t 15 (381) I 5-1/2 (140) /2(89) 00 I 1 i 00 � t 85-1/4 2165) an c 27 ( 3) _J 686 j ( ) SIDE VIEW 11 1 (25) 19-10) 18-3/8 (279) r2(51) (495) (467) !MITI I II: III IIIIII (508) / —€ --/— [00 /� / 1 I 00 FORKLIFT SLOTS HORIZONTAL 5-1/2 HORIZONTAL 5-1/2 (Front, Back and SUPPLY AIR (140) RETURN Blower End) OPENING PENING AIR (140) (Without Economizer) 29 (737) BACK VIEW ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow Applications) OPTIONAL OUTDOOR/ AIR HOOD (Fumished with Economizer) 17 -3/8 (441) 036 thru 048 20-3/4 (527) 060 thru 072 OPTIONAL BAROMETRIC RELIEF HOOD (Fumished with Economizer) OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) H12-3/4 (324) 036 thru 048 16-3/4 (425) 060 thru 072 9 A 0 0 C f- D No. in. mm in. mm in. mm 0 mm 036, 048 19 -3/4 502 ti – – 12 -3/4 324 17-3/8 441 060, 072 SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Furnished) Model A B C D No. in. mm in. mm in. mm in. mm 036, 048 19 -3/4 502 13 -1/8 333 12 -3/4 324 17-3/8 441 060, 072 23 -3/4 603 17-1/4 438 16 -3/4 425 20 -3/4 527 OUTDOOR AIR DAMPER HOOD DETAIL FOR OPTIONAL MANUAL OR MOTORIZED OUTDOOR AIR DAMPERS (Down -Flow or Horizontal Applications) 00 OUTDOOR AIR DAMPER HOOD ( Fumished) SIDE VIEW OPTIONAL OUTDOOR AIR DAMPERS AND PANEL 35 (889) OUTDOOR AIR, DAMPER HOOD 13-1/2 `(343) 4 6-1/2 Oil (267) (419) 35 (889) 036 thru 048 43 (1092) 060 thru 072 Energence. Packaged Gas / Electric 3 to 6 Ton / Page 49 o O O 00 OUTDOOR AIR DAMPER HOOD ( Fumished) SIDE VIEW OPTIONAL OUTDOOR AIR DAMPERS AND PANEL 35 (889) OUTDOOR AIR, DAMPER HOOD 13-1/2 `(343) 4 6-1/2 Oil (267) (419) 35 (889) 036 thru 048 43 (1092) 060 thru 072 Energence. Packaged Gas / Electric 3 to 6 Ton / Page 49 ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL WITH OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Horizontal Applications) 11 'NO are ECONOMIZER DAMPERS �oo SUPPLY AIR DUCT (Field Provided) SUPPLY AIR OUTLET TOP VIEW 19-1/2 (495) HORIZONTAL SUPPLY AIR OPENING RETURN AIR DUCT TRANSITION (Field fabricated and installed on unit) 29-1/4 (743) This opening 1 not used in Horizontal Applications 1 with 20 Economizer I I L_J I I BACK VIEW 5 (127) E dE U 0 � Ero .f\ RETURN AIR INLET OUTDOOR AIR HOOD (Fumished with Economizer) 001 RETURN AIR DUCT (Field Fabricated - Must be sized to accommodate Barometric Relief Hood and Retum Air Requirements) BAROMETRIC RELIEF HOOD DIMENSIONS Width - 35-1/2 in. (902 mm) Height -21 in. (533 mm) (036, 048) 25 in. (635 mm) (060, 072) See previous page for details. NOTE - Horizontal applications with Economizer require Horizontal Economizer Conversion Kit. See Options /Accessories table. BAROMETRIC RELIEF HOOD (Fumished with Economizer and Field Installed on Field fabricated Retum Air Duct) OUTDOOR AIR RETURN AIR DUCT TRANSITION (Field fabricated and installed on unit) HORIZONTAL RETURN AIR OPENING EXHAUST AIR RETURN AIR DUCT INLET (Field Fabricated - Must be sized to accommodate Barometric Relief Hood and Return Air Requirements) NOTE - Retum Air Duct and Transition must be supported. Energence° Packaged Gas / Electric 3 to 6 Ton / Page 50 owl 7/8 (22) 001 2 -1/4 (57) UNIT RETURN AIR DUCT OPENING WITH ECONOMIZER INSTALLED END VIEW 1 -7/8 (48) 2 -1/4 t (57) A 30 -7/16 „,,.. +I (773) owl 7/8 (22) 001 2 -1/4 (57) UNIT RETURN AIR DUCT OPENING WITH ECONOMIZER INSTALLED END VIEW ACCESSORY DIMENSIONS- INCHES (MM) CLIPLOCK 1000 ROOF CURBS - DOUBLE DUCT OPENING 1 -13/16 (46) 41 -1/2 76-1/8 21-1/8 (537) (1054) (1934) 37 -7/8 79-3/4 (962) '8 (2026) 19 -1/8 (486) 15 118 SULY (384. OPENING 1/8 $ (321) ` 1 -13/16 2 -5 (46) RETURN OPENING ,r `�/ r 32 Nisii4414414% (813) � 8 (203) 14 (356) 18 (457) 24 (610) TYPICAL FLASHING DETAIL FOR ROOF CURB BASE BOTTOM FIBERGLASS INSULATION (Fumished) NAILER STRIP ( Fumished) ROOF CURB (Extends around entire perimeter of unit) RIGID INSULATION (Field Supplied) PACKAGED UNIT COUNTER FLASHING (Field Supplied) CANT STRIP , (Field Supplied) ROOFING / MATERIAL NOTE - Roof deck may be omitted within confines of curb. DETAIL ROOF CURB 8 (203) 14 (356) 18 (457) 24 (610) �\ FACTORY INSTALLED PERIMETER WOOD . i NAILER STRIP 1 -13/16 (46) Energencee Packaged Gas / Electric 3 to 6 Ton / Page 51 ACCESSORY DIMENSIONS - INCHES (MM) HINGED ROOF CURBS - DOUBLE DUCT OPENING 8 (203) 18 (457) 24 (610) TYPICAL FLASHING DETAIL FOR ROOF CURB BASE BOTTOM PACKAGED UNIT FIBERGLASS INSULATION (Furnished) NAILER STRIP (Fumished) ROOF CURB (Extends around entire perimeter of unit) COUNTER FLASHING (Field Supplied) CANT STRIP / (Field Supplied) ROOFING MATERIAL RIGID INSULATION (Field Supplied) Energence Packaged Gas / Electric 3 to 6 Ton / Page 52 NOTE -Roof dad( may be omitted within confines ofash. DETAIL ROOF CURB 1 -13/16 .�{ (46) 10— 1/2 (13) 8 (203) 18 (457) 24 (610) 1 -13/16 (46) FACTORY INSTALLED PERIMETER WOOD .s NAILER STRIP • ACCESSORY DIMENSIONS - INCHES (MM) STANDARD ROOF CURBS - DOUBLE DUCT OPENING TYPICAL FLASHING DETAIL FOR ROOF CURB BASE BOTTOM FIBERGLASS INSULATION (Fumished) NAILER STRIP (Fumished) ROOF CURB (Extends around entire perimeter of unit) RIGID INSULATION (Field Supplied) i PACKAGED UNIT COUNTER FLASHING / (Field Supplied) CANT STRIP (Field Supplied) ROOFING / MATERIAL DETAIL ROOF CURB 1-13/16 (46) r___ 1(5) FACTORY INSTALLED PERIMETER WOOD NAILER STRIP 14 (356) L --� 2(51)14-- Energence° Packaged Gas / Electric 3 to 6 Ton / Page 53 'ACCESSORYDIMENSIONS - INCHES (MM) TRANSITIONS 1 32 (813) 12 -5/8 (321) TITRANIOAN -1 - FOR 18 INCH (457 MM) DUCT TITRAN2ON -1 - FOR 20 INCH (508 MM) DUCT (305) 31 -1/2 (800) 8 (203) 1 -1/2 inch (38 mm) TITRAN10AN -1 2 inch (51mm) T1TRAN2ON -1 RETURN TRANSITION 1 RETURN i OPENING 7 ' SUPPLY OPENING 1 Energence® Packaged Gas / Electric 3 to 6 Ton / Page 54 TITRANIOAN -1 - FOR 18 INCH (457 MM) DUCT TITRAN2ON -1 - FOR 20 INCH (508 MM) DUCT 1 -1/2 inch (38 mm) TITRAN10AN -1 2 inch (51mm) T1TRAN2ON -1 SUPPLY TRANSITION J ACCESSORY DIMENSIONS - INCHES (MM) COMBINATION CEILING SUPPLY AND RETURN DIFFUSERS STEP -DOWN CEILING DIFFUSER FLUSH CEILING DIFFUSER Model Number RTD9 -65 RTD11 -95 A in. 47 -5/8 47 -5/8 mm 1159 1159 B in. 23-5/8 29-5/8 mm 600 752 C in. 11 -3/8 14 -3/8 mm 289 365 D in. 21 -1/2 27 -1/2 mm 546 699 E in. 45 -1/2 45 -1/2 mm 1156 1158 F in. 22 -1/2 22 -1/2 mm 572 572 G in. 11 -1/2 11 -1/2 mm 292 292 H in. 10 -3/4 13-3/4 mm 273 349 J in. 45 -1/2 45-1/2 mm 1156 1156 K in. 21 -1/2 27 -1/2 mm 546 699 L in. 7 -1/8 8-1/8 mm 181 206 Duct Size in. 18 round 20 round mm 457 round 508 round D Model Number FD9 -65 FD11 -95 A in. 47 -5/8 47 -5/8 mm 1159 1159 B in. 23 -5/8 29 -5/8 mm 600 752 C in. 13-1/2 16 -5/8 mm 343 422 D in. 21 27 mm 533 686 E in. 45 45 mm 1143 1143 F in. 22 -1/2 22 -1/2 mm 572 572 G in. 11 -1/4 11 -1/4 mm 286 286 H in. 10 -1/2 13 -1/2 mm 267 343 Duct Size in. 18 round 20 round mm 457 round 508 round Energence• Packaged Gas / Electric 3 to 6 Ton / Page 55 a • REVISIONS Section Description Options / Accessories Commercial Control Systems updated. Sunsource® Commercial Energy System Components updated. An ru.�i CERTIFIED,.. �rw w.ahr,rl:rnt'IUi Y urq Ilnitary SnLill AC AHRI S:u +U:rU 210'230 /11 RIM CERTIFIED:.. v.v.,v.ah,i onrettur'v.6ry Unitary Little AC AHRI StandaN 3:0/360 LENNOX) rii.. l CERTIFIED:.. C nnvv.an Atli:.v lniy rirc IM£MB£R COMPANY <IJCl!�1� t_,1•II1V REGISTERED QUALITY SYSTEMS Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at 1- 800.4-LENNOX NOTE - Due to Lennox' ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 02012 Lennox Industries, Inc. `PERMIT COORD COPS( PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -155 DATE: 10/04/12 PROJECT NAME: HOME DEPOT SITE ADDRESS: 6810 S 180 ST X Original Plan Submittal Response to Correction Letter #_ Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: s � B uilding Divi on 4WC/ Fire Prevention Public Works ❑ Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Complete 17,1 DUE DATE: 10/09/12 Not Applicable ❑ Comments: Permit Center. Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required I I No further Review Required ❑ REVIEWER'S INITMLS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/06/12 Approved n Approved with Conditions 1><1 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople inter Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name ANDERSON AIR CONDITIONING LP UBI No. 603055391 Phone 7148886800 Status Active Address 2100 East Walnut Ave License No. ANDERAC901 P9 Suite /Apt. License Type Construction Contractor City Fullerton Effective Date 10/29/2010 State CA Expiration 10/29/2014 Date Zip 92831 Suspend Date County Out Of State Specialty 1 Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Business Type Partnership Specialty 2 Unused Parent DAC ACQUISITION CO LLC Company Business Owner Information Name Role Effective Date Expiration Date AMS AMERICA INC Partner 10/29/2010 BECK, TODD ALAN Partner 10/29/2010 Bond Information Bond 1 Page 1 of 1 Bond Company Name Bond Account Number FEDERAL INS CO 82189659 Effective Date 10/26/2010 Expiration Date Cancel Date Impaired Date Until Cancelled Bond Amount $6,000.00 Received Date 10/29/2010 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 Hartford Fire Ins Co 01UENOC1240 03/01/2010 03/01/2013 $1,000,000.00 03/05/2012 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 10/29/2012 7 ME1 IIIEIIGDJL ILMV.fr 6810 S; 180TH STREET TUKWILA, WASHINGTON ABBREVIATIONS & AND L ANGLE @ AT E CHANNEL Q CENTERLINE DIAMETER OR ROUND (E) EXISTING # POUND /5 E PROPERTY LINE ACOUS. ACOUSTICAL A.D. AREA ORA:N ADJ. ADJUSTABLE A/C AIR - CONDITIONING AGGR. AGGREGATE A.B. ANCHOR BOLT AFF. ABOVE FNISHED FLOOR AFG. ABOVE FINISHED GRADE AL. ALUMINUM ALT. ALTERNATE A.P. ACCESS PANEL ANOD. ANODIZED ANC. ANCHOR APPROX. APPROXIMATE ARCH. ARCHITECT /URAL ASB. ASBESTOS ASPH. ASPHALT AUTO. AUTOMATIC BD. BITUM. BLDG. BLK. BLKG. BM. 60T. BSMT. B.U. CAB. C.B. CEM. CER. C.I.P. C.J. CLG. CLKG. CLO. CLR. CMU CNTR. COL. CONC. CONN. CONSTR CONT. CORR. CPT. CSMT. CTR. CTSK. DBL. DEPT. DTL. D.F. DIA. DIAG. DIM. DISP. DIV DK. DMT DN. D.O. D.P. DR. DS. D.S.P. DWG. DWR. E. EA. E.J. EL. ELEC. ELEV. EMER. ENCL. E.P. EQ. QPT E.W.0 EXP. EXPO. EXST. EXT. F.A. F.B. F.D. FDN. F.E. F.E.C. F.H.C. RN. FL. FLASH. FLUOR. F.O.C. F.O.F. F.O.M. F.O.S. FPRF. F.S. FT. FTG. FURR. FUT. GA. GALV. G.B. GL. GND. GRD. G W.B. GYP. H.B. H.C. HDBD HDWD HDWE. HT W.M. HORIZ. H.P. HR. H.W.H. I.D. NSUL. NT NV. BOARD BITUMINOUS BUILDING BLOCK BLOCKING BEAM BOTTOM. BASEMENT BUILT -UP CABINET CATCH BASIN CEMENT CERAMIC CAST IRON CAST -N -PLACE CONTROL JOINT CEILING CAULKING CLOSET CLEAR CONCRETE MASONRY UNIT CENTER COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CORRIDOR CARPET CASEMENT CENTER COUNTERSUNK DOUBLE DEPARTMENT DETAIL • DRINKING FOUNTAIN DIAMETER DIAGONAL DIMENSION DISPENSER DIVISION DARK DEMOUNTABLE DWN DOOR OPENING DAMPPROOFING DOWNSPOUT DRY STANDPIPE DRAWING DRAWER EAST EACH EXPANSION JOINT ELEVATION (HEIGHT) ELECTRICAL ELEVATOR EMERGENCY ENCLOSURE ELECTRICAL PANELBOARD EQUAL EQUIPMENT ELECTRICAL WATER COOLER EXPANSION EXPOSED EXISTING EXTERIOR FIRE ALARM FLAT BAR FLOOR DRAIN FOUNDATION FIRE EX : ING(ISHER FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FINISH FLOOR FLASHING FLUORESCENT FACE OF CONCRETE FACE OF FINISH FACE OF MASONRY FACE OF STUD F IREPROOF FULL SIZE FOOT OR FEET FOOTING FURRING FUTURE GAUGE GALVANIZED GRAB BAR GLASS OR GLAZING GROUND GRADE GYPSUM WALL BOARD GYPSUM HOSE BIB HOLLOW CORE HARDBOARD HARDWOOD HARDWARE HEIGHT HOLLOW METAL HORIZONTAL HIGH POINT HOUR HOT WATER HEATER INSIDE DIAMETER (DIMENSION) INSULATION INTERIOR INVERT .;AN JT KIT. LAB. LAM LAV LB LKR. LP LVR MASY MAX. M.B. M C. MECH. MED. MEMB. MTL. MH. MN. MR. MISC. M.O MOD. MTD. MAT MULL N. N.IC. No OR 11 NOM N.T.S. O.A. OBS O.0 O.D OFF. O.H. OPP. OPNG. P.A. PRCST PL P .AM. P.AS `YW P D .R P- P7D P T.D.R PTN, P T R. Q.T. RAD R.D. REF. REFR. REINF READ. RESL. RGTR RM. R 0. RIND. R L 5. 5 C. S C.D. SCHED. S.D. SECT. S.F. SH SHR SHT. SHTG SIM. S.N.D. S.N.R. SPEC. SQ. SS SSK STA STD. STL STRUCT SUSP. SYM TB TEL. T. &G THK. THRESH T.O C. T O.G. T O.L. T.O.P. T.0 S. T O.W. T P.D. TRD. TV UNF. UR. LION VERT VEST. W. W/ W.C. WD WIN. W/O WP. WSCT. WT. W.W.F .;ANITOR JOINT KITCHEN - ABORATORY LAMINATE :.AVATORY ..AG BOLT LOCKER LOW POINT LIGHT I WEIGHT) LOUVER MASONRY MAXIMUM MACHINE BOLT MEDICINE CABINET MECHANICAL MEDIUM MEMBRANE METAL MANHOLE MINIMUM MIRROR MISCELLANEOUS MASONRY OPENING MODULAR MOUNTED MATERIAL MULLION NORTH NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OVERALL OBSCURE ON CENTER OUTSDE DIAMaE. TER (DIMENSION; OFFICE OVERHEAD OPPOSITE OPENING PLANTING AREA PRECAST PLATE PLAS'IC LAMINATE a AS-ER PLYWOOD PAR POpT PAPER TOWEL DISPENSER PAPER TOWEL DISPENSER/ RECEPTACLE PARTITION PAPER TOWEL RECEPTACLE QUARRY TILE RISER RADIUS ROOF DRAW REFERENCE REFRIGERATOR REINFORCED /MENT REQUIRED RESILIENT REGISTER RCCM RCUG•- OPENING REDWOOD RAIN WATER LEADER SOUTI -' SOLID CORE SEAT COVER DISPENSER SCHEDULE SOAP DISPENSER SECTION SQUARE FOOT /FEET SHELF SHOWER SHEET SHEATHING SIMILAR SANITARY NAPKN DISPENSER SANITARY NAPKN RECEPTACLE SPECFICATION SQUARE STANLESS STEEL SINK S STATON STANDARD STEEL STORAGE STRUCTURAL SUSPENDED SYMMETRICAL TOWEL BAR TELEPHONE TONGUE AND GROOVE THICK/NESS THRESHOLD TOP OF CURB TOP OF GRADE TOP OF LEDGER TOP OF PAVEMENT TOP OF STEEL TOP OF WALL TOILET PAPER DISPENSER TREAD TELEVISON TYPICAL UNFINISHED URINAL UNLESS OTHERWISE NOTED VERTICAL VESTIBULE WIWEST TH WATER ER CLOSET: WOOD WNDOW WITHOUT WATERPROOFING WAINSCOT WEIGHT WELDED WIRE FABRIC SHEET INDEX CV' COVER SHEET SP -I SITE PLAN SP -2 SITE DETAILS Al A A2 A2A A3 AG A4A A5 A5.1 A5A A6 A7 A7A A8 A9 A10 AiOA Ali Al2 SDI EI FIA FLOOR PLAN GARDEN CENTER ROOF AND FLOOR PLANS ROOF PLAN ROOF DETAILS ELEVATIONS ENTRY PACKAGE ENTRY PACKAGE DETAILS OFFICE PACKAGE OFFICE PACKAGE DETAILS DTAT ROOM, VAULT, AND COUNTING ROOM DETAILS RECEIVNG PLAN GARDEN CENTER GARDEN CENTER DETAILS DOOR & FINISH SCHEDULE DOOR DETAILS BLDG SECTIONS / DETAILS BLDG. SECTIONS / DETAILS MISC DETAILS KITCHEN PLAN SIGNAGE DWG. FIXTURE PLAN FIXTURE PLAN SI GENERAL NOTES S2 FOUNDATION PLAN S2A GARDEN CENTER PLAN 53 ROOF FRAMING PLAN 54 FOUNDATIONS, SECTIONS, DETAILS S5 RENOVATION, SECTIONS AND DETAILS 56 ROOF SECTIONS AND DETAILS 57 MSC. SECTIONS AND DETAILS S8 CANOPY FRAMNG, SECTiONS,AND DETAILS S9 CANOPY FRAMING, SECTIONS,AND DETALS SI O CANOPY FRAMING, SECTIONS,AND DETAILS SI OA CANOPY DETAILS 5' I MEZZANINE FOUNDATION AND FRAMING DETAILS 5 i 2 HPE AND HIGH CANOPY DETAILS 513 GARDEN CENTER SECTIONS 5i4 PANEL DETAILS SI5 -DOCK FOUNDATION PLAN AND PANELS SI6 PANEL DETAILS 5:7 STAIR SECTIONS AND DETAILS K •7 HEN DISPLAY DETAILS • P -: PLUMBING LEGEND; SCHEDULES & NOTES P -2 PLUMBING FLOOR PLAN P-3 PLUMBING FLOOR PLAN M -1 MECHANICAL LEGEND, SCHEDULES, DETALS, & NOTES M -2 MECHANICAL ROOF PLAN M-3 MECHANICAL PLAN M -4 OFFICE PACKAGE PLANS M -5 FLOOR PLAN EM -I SCHEDULES EM-2 SCHEDULES 5 -1 LEGEND, LIGHT FIXTURE SCHEDULE & NOTES 5-1.1 SITE PLAN 5 -2 ELECTRICAL DETAILS E-3 FLOOR PLAN - POWER 5 -4 FLOOR PLAN - LIGHTING 5 -5 ELECTRIC PLAN - GARDEN CENTER E 5 i DETAILS -ELECTRICAL GARDEN CENTER - POWER PART P;.AN CHECKOUT ELECTRICAL E-6 ' PART PLAN CHECKOUT ELECTRICAL E 7 OFFICE PACKAGE PLANS 5 -7.1 OFFICE PACKAGE DETAILS E -8 ROOF PLAN STORE E -9 SCHEDULES AND DETALS E -ID DATA ROOM - ELECTRICAL E -1 i DATA CABLNG SCHEMATIC E- 2 PANEL SCHEDULES E -13 PANEL SCHEDULES E -14 SINGLE LINE DIAGRAMS E -5 2 E-6 FRI FP2 F 3 FP4 L-2 SITE FIRE PROTECTION FIRE PROTECT:ON FLOOR PLAN CALCULATIONS CALCULATIONS IRRIGATION PLAN LANDSCAPE PLAN CONSULTANTS OWNER 5- RUCTuRAL MECHANICAL & PLUMBING ELECTRICAL EIRE HOME DEPOT U S.A., INC 6C' SOUTH PLACENT.A FULLER T ON, CA 9263; :714)738 -52D0 Permit i GENERAL NOTES ARCHITECTURAL 1 A SEPARATE PERMIT (N.I.C.) IS REQUIRED FOR SIGN INSTALLATION" 22 WELDING SHALL BE PERFORMED IN THE SHOP BY AN APPROVED FABRICATOR OR CERTIFIED WELDER UNDER THE SUPERVISION OF THE SPECIAL INSPECTOR. 3. A CERTIFICATE OF FABRICATION FROM THE SHOP PERFORMING THE WELDNG OR SPECIAL INSPECTOR'S REPORT SHALL BE PROVIDED TO THE CITY INSPECTOR PRIOR TO FRAMING APPROVAL. 4. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE DEVELOPER THE LOCATION OE CONSTRUCTION TRAFFIC FOR THIS PROJECT. 5. ALL EXIT DOORS SHALL SWING N THE DIRECTION OF 6. PER UBC 33i3 8 3314 ALL EXITS SHALL BE ILLUMINATED AT ALL TIMES WITH A MINIMUM I FOOT CANDLE RATING AT FLOOR LEVEL ALL EXIT SYSTEM CIRCUITS SHALL BE ON EMERGENCY POWER BACK -UP AND SEPARATE CIRCUITS FROM NORMAL PREMISE WIRING. 7. PROVIDE AND INSTALL 12' BUILDING ADDRESS NUMBERS ON THE BUILDING N A POSITION THAT 5 VISIBLE AND LEGIBLE FROM THE STREET PER UFC 10208. 8. AISLES SHALL BE NOT LESS THAN 44• CLEAR WIDTH AT EXIT ACCESS PER UFC 81.108. FIRE PROTECTION 1. THE FIRE SPRINKLER SUBCONTRACTOR SHALL PROVIDE AN APPROVED FIRE PROTECTION SYSTEM PER THESE DOCUMENTS AND ALL OTY AND STATE REQUIREMENTS. 2. PROVIDE SUPERVISION FOR THE FIRE SPRINKLER SYSTEM PER UBC SECTION 3803. 3. SUBMIT FIRE SPRINKLER SYSTEM PLANS TO THE LOCAL FRE AUTHORITY HAVING JURISDICTION AND OBTAIN ALL NECESSARY APPROVALS PRIOR TO INSTALLATION. 4. THE COMPLETED FIRE SPRINKLER SYSTEM SHALL BE TESTED AND ACCEPTED BY THE FIRE AUTHORITY HAVING JURISDICTION PRIOR TO OCCUPANCY OF THE BUILDING. 5. FIRE ALARM SYSTEM BY OTHERS (N I C ) SITE I. ALL REQUIRED PUBLIC FIRE HYDRANTS SHALL BE TESTED AND APPROVED BY LOCAL AGENCIES PRIOR TO CONSTRUCTION OF THIS PROJECT. 2. FIRE HYDRANTS (N.I.C.) SHALL BE OF TYPE, QUANTITY AND LOCATION PER LOCAL FIRE AUTHORITY REQUIREMENTS 3. CONTRACTOR SHALL ALLOW FOR ONE EXTRA STAGING MOVE FOR THIS PROJECT. 4. CONTRACTOR MAY AT HIS DISCRETION PROVIDE A CONSTRUCTION STAGING AREA FENCE. ALL PERMITS & FEES SHALL BE PAID FOR BY THE CONTRACTOR. 5. WHEN NOTES IN THIS DOCUMENT STATE 'SEE CIVIL' THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THE CIVL ENGNEERING DOCUMENTS. Pr 'ZA N 471-lee: P/2 C -) -rally? GW?1Ot4 COO.1r2a, G -� 'fil:.trlt0L TIOt -1 FGA1.4 G -3 UTIUr\( 6 -4- 1,7 u12L1-WaQCstel. 1,, 611&.21,-.61 ,41W7 G. (I 1i''0'Z tZOVIT14 Wi LovO (z0>, 6.1 1:-/m/1 ke R.A.4 d. iota TV4 ! G, e� 6'19 UrtUtr`{ avttO P,1 Se r;t401-4S_. G �• 1 viu12t1.k paa G6W1O :AN19_ T M-Z hoczwi.. ¢fst6 Ur1 VI r f�Ea cL/+T1+a�J 0.7 is - BARRY LEVIN 8 ASSO r to Q !8006 SKYPARK CIRC(� �e 1��54F � �,%1 II � is subject W errors �w IRVNE CA 92714 i714) 833 -3970 con ruction documents does ligtothcrize PACIPICA ENGINEERS 129 WEST WILSON ST ITE 105 �AI COSTA MESA, CA 9187 . _ :r :,57.�l 1 i%: t,:.` '� ` WIV ed code or or Wllance• 'p` (74)650 -9970 o� I°:.--.fr ,,.,,( EU conditions is acknowledged: 4,RtEDESGNGROUP 4 �.,� %`,jFci1�VW 1�� �7 4901 MORENA BOULEVARD E ;26 dii\_ �• SAN DIEGO, CA 92117 :619;274 -2905 LANDSCAPE WEISMAN DESIGN GROUP 2329 EAST MADISON �q SEATTLE, WASHNGTON 981 12," Date: SEPARATE PERMIT REQUIRED FOR 0 Mechhanic& Madded .. Q'Plumbkv .$as MARI City of Tukwila lG+l_DING DIVISION •`r' VICINITY MA pUILDING CODE ANALYSIS s t lrilding Use Occupancy Classification I Construction Type Basic Allowable urea Separation Vord size Sprinklers Allowable Area Increases Actual Building Area Total Area w/ canopies FETAL B -2 1 TYPE V -N 8000 SF 1 60 FT, 4 SIDES 100 Y. UNLIMITED !47,844 SF. 153,201 S.F. SMOKE VENTILATION A ( 1491 t1FC TABLE NO. 81.107 v.. UFC Hazard Classificot on Designated Storage Height Curtain Board 1 Mox. Area Depth Curtain Boards Vent Area o Floor t Area Max. Space I • Max . Distance to Vent Center i from Boo or IV 20 6 FT. L21000 S. I:i00 100 FT. 60 FT 0 REVISIONS r'1 rh1npns shsli be made to the scope c f \,r.r% tuithout prior approval of .`u'c. v'sla Building Division. 1, v's!ons will require a new plan submittal r� may ino'ude additional plan review fees. FIRE ACCESS /EXIT ANALYSIS 1991 UFC, 1991 UBC. Building Use Occupancy Classification Occupancy Load Ratio Actual Binding Area Occupant Load Required (bldg.areo Exit W'dth I , per 30 s.f.) ,occupants X 2) Actual Exit Pr d /.Y RETAIL B-2 30 /SF. 147,84a SF 4928 • 30 992 LW W. (SALES AREA • i/2 (83 LN FT.) ME771 1 6 LIN. N. 59 I ( 5 UN FT) 11242 LIN N. ". 7 cT ) t (10_5 LI_N. ) 33 LNN . (2.75 LIN. FT.) . - J Ili _��i t 1- :ii::: � `` :,1 IT I CI S. .I: 1 4.I - 1 :I: I 1 1 ( ail L I k .1.r 1 4 ! 4 I :,. I - .1- k 4, 1j lit. r- I F r ;ID 4 I 1 471 :11:- - I ' L.,,,..--' -i�l IL__ I FIRE ACCESS /EXIT ANALYSIS 1991 UFC, 1991 UBC. Building Use Occupancy Classification Occupancy Load Ratio Actual Binding Area Occupant Load Required (bldg.areo Exit W'dth I , per 30 s.f.) ,occupants X 2) Actual Exit Pr d /.Y RETAIL B-2 30 /SF. 147,84a SF 4928 • 30 992 LW W. (SALES AREA • i/2 (83 LN FT.) ME771 1 6 LIN. N. 59 I ( 5 UN FT) 11242 LIN N. ". 7 cT ) t (10_5 LI_N. ) 33 LNN . (2.75 LIN. FT.) . i 780 5F (MEZZANINE) CURTAIN BOARD AREA 48' X 108' - 5184 S.F. SMOKE VENT AREA REQUIRED SMOKE VENT AREA PROVIDED 518 S.F. + 100 - 52 S.F. 4'X8' - 32X2 -64 S.F. CURTAIN BOARD AREA 96' X 108' - 10368 SF. SMOKE VENT AREA REQUIRED SMOKE VENT AREA PROVIDED 10368 S.F. + 100 - 104 SF. 4'X8'- 32X4- 128S.F.' CURTAIN BOARD AREA 96' X 108' - 10368 S.F. SMOKE VENT AREA REQUIRED SMOKE VENT AREA PROVIDED CURTAIN BOARD AREA SMOKE VENT AREA REQUIRED SMOKE VENT AREA PROVIDED 10368 S.F. + 100 - 104 S.F. 4'X8'- 32X4 -128 S.F. 96' X 108' - 10368 S.F. 10368 S.F. + 100 - 104 S.F. 4'XB'- 32X4- 12BSF.' BUILDING EXIT PROVIDED NET NET OPENNG DOOR WIDTH EXIT WIDTH • 14'X7' 13.0' 4 52 L.F. ® 6'X7' 5.75' X I. . © 3'X7' 2.75' X 1 - 2.75 L.F TOTAL EXIT YWDTH 106.5 L.F MEZZANINE EXIT PROVIDED --� ® 3' X 7 2.75' X I - 2.75 L.F. at ADDITIONAL EXITS NOT CALCULATED ,00 u M,Or SWIM NO Ielli ®1 Fir- 1 11 11 11 1 11 11 1111 a _os._ea- G�tl G�tl (Gid E tr+d e4Y Mhire0114111011111i",:= 111111111111 A B O 0 ,p B 11 11 11 I 1 1 1 1 11 1 11 11 11 11 11 11 CT 2 2012 AT wJ a ity of Tukwila DING DIVISION RECEIVED CITY OF TUKWILA OCT 0.4 2012 PERMIT CENTER 12 -I 6 PROGRESS PRINTS rn REVISIONS AFTER PARTIAL OR FULL RELEA Yi SHEET TITLE 1/16 " -1' -0" COVER SHEET z m 3 O 0:4411 n O 30 1/16- = 1' -0" SMOKE CURTAIN BELOW DE SEE SOUTH DETAIL SI 11 OF /A2A BEAM REVIEWED FOR )DE COMPLIANCE APPROVED OCT 2 s 2012 City of Tukwila ILDING DIVISION OCT 5 5 0 4 2012 ` PERMIT CENTER 1011911::12 £ 4�; 111 1{4 01111111 413111 " !Hit nifiat, Z a OR FULL RELEASE REVISIONS AFTER PARTIA 0 Q 0 cc c co w o 0 I Z W W ;, cn lo z ° _ Lt' i. U W � Sc- Z U) Z N w0 Q Q (' o°� ao Q Y, wWW F- D F G D Y W Li'°00D w S U) P. v=i 9 I z I @ $UU a Jg-' < g1 W m1 w` W ce o N - SMOKE CURTAIN BELOW EAST SIDE OF BEAM - ' 'OOF DRAIN SEE DETAIL 11/A2A Ibill _ / -, r 1 1 _ 11 1�I ,I 1 ��/ _J AG4 SATELLITE DISH SUPPORT STRUCTURE . _ „ ' \ RV -2 I \ ■ �, � 1 1 1 1 9 ►1 i : ∎A mil : ' 11i mm 11I \"� \� 111 li/ ' i \1 Al \��' 1% \� 11 SMOKE CURTAIN BELOW - SOUTH SIDE OF BEAM - SEE L�71 !I h — • / MAU -i � / •' �L1 MAJ 3 , MAU -5 N 4, , A. R-4 , \1. RV -5 ' \ RV -3 �. \ /� I� '4/ \ ' \'1 A.. DETAIL 11/A2A , LINE OF OFFICE 11i i 14i XI e 0 I I 1' ►1 ' oi� :N :11 1 11 0 011/ RV -8 \ RV -6 BLOCK BELOW \�1 � / 1/ \ \ �l \) �1. 8J 1. Ell r 1 45 A AM 1T40 FA/- I AFA EXISTING SK1•LIGHT TO BE RELOCATED FILL IN OPENING IN SHEATHING k REVISE FRAMING 1 V4 '1 / 120' X 32' SA. DUCT (ere. OF b) N / I .1 \ • \" 1�/ 1 "�, �• / \'1 Al \a' -„ RV -!O \ RV-II \ I RV-41 y AS REOUIREO A \ . e ° 1/ 1/ 1. .1. \ \1 \ _ ° / \ 1 J GUTTER W/ GUTTER Q ROOF VENT 46" X :6' THROAT AREA (TYP. OF 11 • 1 40° 1� 1 1■ 1 • Amu 1� v �►:� 11 ■1 -� 1 v 1r GUTTER DOWNSPOUTS v v v v OU? EA. END c++ CI T I. f 30 1/16- = 1' -0" SMOKE CURTAIN BELOW DE SEE SOUTH DETAIL SI 11 OF /A2A BEAM REVIEWED FOR )DE COMPLIANCE APPROVED OCT 2 s 2012 City of Tukwila ILDING DIVISION OCT 5 5 0 4 2012 ` PERMIT CENTER 1011911::12 £ 4�; 111 1{4 01111111 413111 " !Hit nifiat, Z a OR FULL RELEASE REVISIONS AFTER PARTIA 0 Q 0 cc c co w o 0 I Z W W ;, cn lo z ° _ Lt' i. U W � Sc- Z U) Z N w0 Q Q (' o°� ao Q Y, wWW F- D F G D Y W Li'°00D w S U) P. v=i 9 I z I @ $UU a Jg-' < g1 W m1 w` W ce o N 11 u - - - - - - -- Iorr T 4IM� � 4 - /\ i/N.\ n 56. 0 UP TO EF -S CONTROL CLOUD. TAEFM5SHAILL INTERLOCK LIGHT W/ MAU -5 & OEENERGI2E UPON CALL FOR HEATING FoL H .LA JT �E .,,,,,m- 4 ( rc* Fish, !PYoJ? 'M -4 El RV -I ?2 R ■i _I I 1 1 TH J 1 UH- ID r ' e P4 - I 1 1 I 1' 1 FLUE UP ROOF r - -- 1 1 A WAC-1 ABC WALL RV-2 pr- 5Et Aix.. pwos L'16411'44 1 I� Go 1 ® I _--- NIu11II1111E • 1 1 r....-4. 1 1 i F 1 I p 1 1 - }Q O PF 7 �� r - ' Q �� "q - - _ PF1® J ( 1 U 1 1 � U- 1 CC 32X46- 36X24- EE 36X32 Q © ER Fi-10 EE © v 141 b1 r r� I+ ! i I I I I 1 I ! 11 LIr.iA j 1:1C) �I 36 X 24 —� 36 X 24-� I 1 I 1 36X24 1_ I 1 I 1 I 1 I 1 °O @ I ��Ira old -x ri1A r r 1' Q' _� I i1 1 i I (. 1 � 1 i 1l I L ) f I 1 f4 �' -36 X 2a /J !Sj1 pt .I. TP oIrr MoL.1N'Eb AT ! ?OM TyFL . P•LIN p1J1 I'IIDE L7 �� Ct f° °� `�' 1 1 1 i3 i i �F i EE PM Y� .. X 40 MAU-3 , -- 1191. I 1 I L _ — } Ib 1 1 1 L 1 1 32 X 46 RV 3 1 ' 1'�N,�T 4•:%1�1L GOLW17i i 1 1 1 -42 32 % 36- 36 X 32 � r I, r'I I I 1 IE = = 36 X 24 '� ILJ 1 A\ I 1 '' RV_5 ! i 1 32 % 36 — 1 I 1 1 -_�i = i 1 1 RV -4 42 X 4d L L_.1 1_,.! I L.J 1 1 1 1 1 1 1 1 1 1 1 ° PF EE P ® 111 - m — EE , PT- 22 EE ® PF -27 o Pr 2t I 1 1 1 1 - )] RV-1 _ EE o ER RV 6 102-X20' RA. ThRU ROOF TO 25' AFF 1 W/ I/4 "XI /4" 8IRDSGRN (TYP. OF 6) \ RV -8 1 1-,- E6 P® 111 EE . P ®g2 ER Oa P �' - - -- ® PF -2a ►Ii 40-40 4 VJ DIFFUSER 36•x36 "X8" 4160 GFM {T11.. OF 48) Y I� ®� q Q ® EE ® PF -2 - el O PFS°1 g36X24 - q_ EE O 36 X 24 MAU-4 J 6 X 36 % 24 —P REVIEWED FOR DE COMPLIANCE .® ► ., I El_ ; �► �, 1; O Fr- 0 L 36 X 24 ` 32 X 46 L 36 X 24 ,D - --x © ® PF -:7 /i L 36 X 32 L4, O Ie X 40 32 X 36 J ® PF- Z� 36 X 24 L O pr-.p 42 X 40 32 X 36 O 15F-4I APPROVED OCT 2 6 2012 q r City of Tukwila BpILDING DIVISION 32X 46 RV -4 35 SA. THRU ROOF TO 2s' AFF _ ITA F 6) {TYP. OF 6) EE �i RV -10 RV -11 A 1 1 lo1zH- 2 .gel _a.. -20' ----.`"4 Q - ._201_.._.��... -V1 d(, i'O -,I�- + I �'- '��___�ii.• b °� I 421-- L CAP-14-8 Giz 4- 1_0 2O1-e" ('t-'r i _2�__ ° A. , f, AT 3 or t -sr- ) 1 M ;�� It calm+ s° � I 1 1 H' , fir- 7 1'_ , . ( 11J(AU ?1iaj 140,08- y 1-46.Alltt- ,14 FF H4 I( 'p ° Lj1 es•w -IS ROOl A� 1" ms \ t i•ce...Tlorl `. P® j1 Ice: � E� ..__Z01 -5 �O ., N-to 642H• 16 .. 0,-.9 !�H- t rte, • r � T4 r~ 1 1I Z I� 1� 'i - 3 6t2H-10- _ a - Y r �` i 1 Ut1'3 T uK_2 ..._2o1 —, L' ' T �) , a. r �: L L 7 t, i� 1 nF T ' —' C;IIY ;A 1/16'= ,•-o- l ss Mo111J ' A 10-6101 A. p P?dvA 1�I I�?2 4;7 '-4d oc1, 0, If 2012 PERMIT CENTER 0 Q 0 CC Op 03 Z 0 w O rn (f) I z cE 1 II . 1- - z z Et U = \ w • 0 w 3 0 a 4 ZI/) z N w 0 vi :3 J o Q O 1-.-1‘-' < z = J le W 'ti WI-� ,_ 0 00D Litt a =U)F H z p 1• OF III a ct i 10 V ec < JI 1 w m Ifni I w4 w IL o MAKE UFD AIR UNIT SCHEDULE MARK CFM EXT. SP. 18.860 WE INPUT MR MG. OUTPUT MBN VOLTS/PH FAN MP PUMP HP VT. LDS MA18•G MODEL MA2-1 33275 1/2• 550 440 480/3 550 20 13.200 .NOTED METH. PRODUCTS 8P332440 MAU -2 8.4 140 7DC -NNOX 2T67,-., 2C -2 1150 .75 34.6 50 37 8.7 460/3 1/2 63 100 550 LENNOX GCS-576- 4730 AC -3 MAU -3 .75 585 75 58 8.9 460/3 3/4 94 159 700 LENNOX GC 653 -7S16- 5 AC -4 600 .75 23.2 50 38 8.7 208/1 1468-4 8.5 180 575 LENNOX GCS16- 271-50 6C -5 600 .75 232 50 38 8.7 208/1 1/3 11.5 18.0 575 LENNOX G76- 26l CS50 MANUAL SUMMER /WINTER SWITCH. MAU -5 3. GAS SUPPLY PRESSURE MUST NOT EXCEED 0.5 PSI. 4, GAS CONNECTION SIZE IS AT UNIT CONNECTION. NOT GAS SUPPLY PIPE SIZE. 5. MAINTAIN FOLLOWING CLEARANCES FROM COMBUSTIBLES+ TOP AND FLUE CONNECTION =6" SIDES =18'; BOTTOM -12'; BACK =24'. 6. MOUNT 20 FEET AFF 7. MOUNT AT 'A DEGREES FROM VERTICAL 18 FEET AFF., 201411 Getti'TEleS. r MoUPl 1 3�i ; TLKEFii f ` T'�-, 18 Feel' d/ I$' c.f..; GEI .IIIE.I�S. .TOTAL FAN SCHEDULE GENERAL NOTES - VAC -'. 300 -- 8.8 - L46KV ELEC. 6. COMPLETE VITHXACK(RAFT DAMPER. ROOF CURD 7. CONTROL WITH LINE VOLTAGE THERMOSTAT. 9.5 115/1 888-6 1.85 -- 1 CARRIER 1 1 1 1 i 1 ALL UNITS TO BE COMPLETE WITH we CV CONNECTION. PRCV DE SMOKE DETECTORS AT SUPPLY AND RETURN PLENUM. UNITS SHALL HAVE PRE-SLOPED FACTORY CURB ON L2' PLYWOOD. A/C UNIT SCHEDULE NARK CFN EXT. SP. INN20 TOTAL COOL MBH HTG INPUT MK HTG OUTPUT NB. EER SEER vOLTS/PH FAN HP COMPR RLA TOTAL 1CA VT LBS MANFG. NODE/ AC -1 1600 75 46.5 75 58 8.6 460/3 V. 8.4 140 7DC -NNOX 2T67,-., 2C -2 1150 .75 34.6 50 37 8.7 460/3 1/2 63 100 550 LENNOX GCS-576- 4730 AC -3 1900 .75 585 75 58 8.9 460/3 3/4 94 159 700 LENNOX GC 653 -7S16- 5 AC -4 600 .75 23.2 50 38 8.7 208/1 1/3 8.5 180 575 LENNOX GCS16- 271-50 6C -5 600 .75 232 50 38 8.7 208/1 1/3 11.5 18.0 575 LENNOX G76- 26l CS50 MANUAL SUMMER /WINTER SWITCH. 2. UNIT HEATER SHALL BE .:ERTIFIED FOR USE IN WASHINGTON. 3. GAS SUPPLY PRESSURE MUST NOT EXCEED 0.5 PSI. 4, GAS CONNECTION SIZE IS AT UNIT CONNECTION. NOT GAS SUPPLY PIPE SIZE. 5. MAINTAIN FOLLOWING CLEARANCES FROM COMBUSTIBLES+ TOP AND FLUE CONNECTION =6" SIDES =18'; BOTTOM -12'; BACK =24'. 6. MOUNT 20 FEET AFF 7. MOUNT AT 'A DEGREES FROM VERTICAL 18 FEET AFF., 201411 Getti'TEleS. r MoUPl 1 3�i ; TLKEFii f ` T'�-, 18 Feel' d/ I$' c.f..; GEI .IIIE.I�S. .TOTAL FAN SCHEDULE GENERAL NOTES - VAC -'. 300 -- 8.8 - L46KV ELEC. 6. COMPLETE VITHXACK(RAFT DAMPER. ROOF CURD 7. CONTROL WITH LINE VOLTAGE THERMOSTAT. 9.5 115/1 -- 1.85 -- 110 CARRIER EVA2091 AC -1 THRU AC -S1 COMPLETE WITH ECONOMIZER. FILTER AUTO CHANGEOVER T -STAT PROVIDE 15/. MIN. O.S.A. WAC -1. SEE ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHT THRU WALL. UNITS SHALL HAVE CURB MADE FROM 4' X 10' MEMBER IN FIELD (BY GENERAL. CONTRACTOR) SEE 4 /A2A FOR CURB DETAIL. HEATER SCHEDULE HARK CFM BTU INPUT BTU OUTPUT HP VOLTS CABINET SIZE INCHES HM VzD VEIGHT LBS NATURAL GAS CONK SIZE 666F0. MODEL REMARKS UH -1 1850 765,000 132.000 1/20 120 30613631 160 1/2• REZNOR FE -165 171-6 EF -2 3cO 1/2 19016 115 1580 671 25 VEERED( SP -127 MACH RM 6.7 GRH -1 1120 .75 1/4 115 1350 109 60 GREENHECK GB -120 TOILETS TO 10 EF-4 LG.a77 G4•. taaP 12 I2C7 317X IiX22sA 41 1/Y 4"L.S CO AL 2.3/•7 I4 #17 6 66,0.'1'/ 6.b.CbO .75 110 31ATK 3G5 X I7'' Cob %U orriGS rn1,S004 2 -j3, +,B LIGHT CLOUD 6.7 Ti,...," f6,FSO - POW 115 2C.C. Lfl17142. P1f Oo NOTES 1. PROVIDE WITH SPARK PILOT OPTION, 4 POINT SUSPENSION KIT, THERMOSTAT & RELAY, & MANUAL SUMMER /WINTER SWITCH. 2. UNIT HEATER SHALL BE .:ERTIFIED FOR USE IN WASHINGTON. 3. GAS SUPPLY PRESSURE MUST NOT EXCEED 0.5 PSI. 4, GAS CONNECTION SIZE IS AT UNIT CONNECTION. NOT GAS SUPPLY PIPE SIZE. 5. MAINTAIN FOLLOWING CLEARANCES FROM COMBUSTIBLES+ TOP AND FLUE CONNECTION =6" SIDES =18'; BOTTOM -12'; BACK =24'. 6. MOUNT 20 FEET AFF 7. MOUNT AT 'A DEGREES FROM VERTICAL 18 FEET AFF., 201411 Getti'TEleS. r MoUPl 1 3�i ; TLKEFii f ` T'�-, 18 Feel' d/ I$' c.f..; GEI .IIIE.I�S. n FAN SCHEDULE MARK CFM SP. TNH2O HP VOLTS RPM SORES VT. LBS WNFG MODEL SYSTEM REMARKS EF -1 650 12 1/4 115 1300 83 50 GREENNECK GB -90 LOCKERS 6 EF -2 3cO 1/2 19016 115 1580 671 25 VEERED( SP -127 MACH RM 6.7 EF -3 1120 .75 1/4 115 1350 109 60 GREENHECK GB -120 TOILETS 6 EF-4 1920 .75 12 115 1350 129 100 GREENIECK GB -140 ELEC. TELE 6 EF -5 1500 .75 V3 115 1400 124 75 GREENR:CK GB -130 LIGHT CLOUD 6.7 Ti,...," f6,FSO - POW 115 2C.C. Lfl17142. P1f Oo GENERAL 8 FAN SCHEDULE GENERAL NOTES 1. CFM AND STATIC PRESSURE CSP.) VALUES NARKED VITH AN ASTERISK CAI INDICATE THE EXTENDED RANGE THAT THE EQUIPMENT MUST BE CAPABLE IT PROVIDING. 2. ALL FANS SHALL BE AMCA TESTED, DERTIFIED, AND LABELER 3. ALL BEARINGS TO HAVE MINIMUM AVERAGE LIFE 4L50) 18 EXCESS OF 200900 HOURS. 4. MBT01 HORSEPOWER 0P) INDICATED IS THE MINIMM THAT VRL BE ACCEPTED. S RPM AND SOWS VALUE INDICATED ARE THE MAXIMUM THAT WILL BE ACCEPTED. A 6. COMPLETE VITHXACK(RAFT DAMPER. ROOF CURD 7. CONTROL WITH LINE VOLTAGE THERMOSTAT. BY GENERAL =TRACTOR CDETATL 41A26). 8. MOUNT AT ELEVATOR OF BOTTOM OF GLU -LAM BEAMS ROOF AIR HOOD SCHEDULE MARK MC THROAT AREA SQ. FT. THROAT SIZE INCHES THROAT VELOCITY FT PER MN. CURB SIZE INCHES HOOD SIZE. INCHES SYSTEM NAMFACTURER LENGTH VIDT% HEIGHT NODEL TO y, 16000 32.0 48'X96' 5K. 56'X30 <' :'-D 77 25- RELIEF GREEN -ECK BRA-HOCD PROVIDE WINTER MOTORIZED DAMPER, TO BE OPEN IN COOLING MODE AND CLOSED IN HEATING MODE. O z\ z\ 3ELOl W - (TYPJ r rrr GARDEN CENTER CANPOY RETRACTABLE SHADECLOTH 5 FRUCTURE 1; _ 1-16-1 HOUSEPT�E.TAN !;! ua -1s GARDEN CENTER c.o.( -S F 1 411111,1 MEMBRANE STRUrTURF 1111 F VII GARDEN CENTER FLOOR PLAN - MECHANICAL REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 6 2012 City of Tukwila BUILDING DIVISION RECEt' CITY OE UKWLA OCT 042012 PERMIT CENTER 1/16' ti(21SS 0 8 5 K Z PROGRESS PRINTS at 1T- r 0 AFTER PARTIAL OR FULL O z W o0Z W z co in z Q V = 0 z Z w0 Q 1n -)Z _c Q 0 -6 co •4 E- Q �WH--§ 000D O. I I FLOOR PLAN cr 0 O O O R U C9 0 v 0 Oa Pea -Z�n0 0 Ix I X = °�m66 a z 0, 5 w¢¢ H- Ii J ARCHITECTURE ^ RAN NIN G RELEASE STATUS OF THIS DRAWING _r r- a) 4- 0 6 � Q F 8 a 2 0•• & Z W J i 2 2 Lc) I II I