Loading...
HomeMy WebLinkAboutPermit M12-156 - UNITED RENTALSUNFED RENTALS 17700 WEST VALLEY HY M12 -156 City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 3623049057 17700 WEST VALLEY HY TUKW Project Name: UNITED RENTALS Permit Number: Issue Date: Permit Expires On: M12 -156 11/14/2012 05/13/2013 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: UNITED RENTALS INC C/O FISCHER & CO URI , 13455 NOEL RD STE 1900 75240 ED GATES PO BOX 428 , AUMSVILLE OR 97325 ED @MILLCREELHTG.COM Phone: 503- 749 -1000 MILL CREEK HEATING LLC Phone: 503 - 749 -1000 PO BOX 428 , AUMSVILLE OR 97325 Contractor License No: MILLCCH888MR Expiration Date: 08/03/2014 DESCRIPTION OF WORK: SHOP CARBON MONOXIDE ( TAILPIPE) FUME REMOVAL SYSTEM UPGRADE. REPLACE FAN, ADD 3 STATIONS, REPLACE 5 NOZZLE.HOSE SECTIONS Value of Mechanical: $22,228.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $465.31 International Mechanical Code Edition: 2009 Date: ll7/ /41 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: ekito C. 14uvki Date: 11'1 7.- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. rinr. IMf: -4/101 M12 -15R Printart• 11 -14 -9012 PERMIT CONDITIONS Permit No. M12-156 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. (Inn. IMf: -4/10 M17 -15R Printari• 11 -14 -7(112 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov 1 Mechanical Permit No. M (,)--t5 ,b Project No. Date Application Accepted: Date Application Expires: 10-S--( 2 Lk- S -,3 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: Tenant Name: ( ??ooWestlialley Hwy UNITED RENT IA L PROPERTY OWNER Name: s'd c-ozk..�s Name: tool rrsD RayCviLS City: Atoms vi lie. State: O it Zip: 97325 Address: %1C 36 7 Email: �_ ,,�� t:CI 41lL L GRGtrkRTG•. GOM City: I QKC. ?or Stag 4 Zip: p176 2. i CONTACT PERSON — person receiving all project communication Name: s'd c-ozk..�s Address: 'P0 13o X 4 Z 8 City: Atoms vi lie. State: O it Zip: 97325 Phone: 503_ 249,-(006 Fax: 503 -744' Lite? Email: �_ ,,�� t:CI 41lL L GRGtrkRTG•. GOM King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes %.No MECHANICAL CONTRACTOR INFORMATION Company Name: MA L GRC -ew /E 7y o Li Address: S1bS- DLLxvi6Y RD SE City: ?�jem eye. State: Q R. Zip:9. 739 Phone: 0 3.7 LJ9 1 Fax: So 3 ..7I/ 3 - 2.y6? Contr Reg No.: CC I I L C Cc k ge Eu p Date: $ '3 ' I y sAR Tukwila Business Liceu No : - ,,. —... _ co— Ogg 383,1 o�v.� t00 Valuation of project (contractor's bid price): $ c2 o` Describe the scope of work in detail: SRC? Gl gR,3 0 t MO1.0 X 1 D C (nig I L p li'E) FrA wt6 RRMp»4 SYST LtP6kAb — Ret'L14CE FAN, AD 3 5Ti4TloNS/ RC Pl -146E- Nozz(.x: /-kosE .5e-c-77045 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ist JAPo- R.IckD- Fuel Type: Electric ❑ Gas ❑ Other: 6)Cti4usT l D R. i2c.C.ES S H:\ Applications\Forms - Applications On Line \2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall /floor mounted heater 2 Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct 2 Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - .Value of construction— in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and.is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension•of time for additional periods not to exceed,90 days each. The.extension shall -be requested in writing and justifiable cause demonstrated. Section 105:3.2 International Building Code (current edition). 1. HEREBY CERTIFY THAT 1 HAVE READ.AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PEjtJORY BYTHE LAWS 'OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT OM ED AGENT: Signature: Date: / c2/ f? Print Name: e-cP 6-gtes Day Telephone:. CC) 3- 71137 /t 0 Mailing Address: Pe 4 OR City. - State ' Zip. H: ApplicationsWorms- Applications On Line'201 1 Applications\Mechanical Permit Application Revised 8 -9 -I I.docx Revised: August 2011 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3623049057 Address: 17700 WEST VALLEY HY TUKW Suite No: Applicant: UNITED RENTALS RECEIPT Permit Number: M12 -156 Status: PENDING Applied Date: 10/05/2012 Issue Date: Receipt No.: R12 -02782 Payment Amount: $465.31 Initials: WER Payment Date: 10/05/2012 10:56 AM User ID: 1655 Balance: $0.00 Payee: MILL CREEK HEATING TRANSACTION LIST: Type Method Descriptio Amount Payment Check 6363 465.31 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 372.25 000.345.830 93.06 Total: $465.31 doc: Receiot -06 Printed: 10 -05 -2012 i. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: ? INIITP_Pi AF NrrenS Type of Inspection: ri OA t Address: \-1100 y,fo s-s- O n H W -1 Date. Called: Special Instructions: - OC- 601c1 -01 Date Wanted:. 1a._ /2 col 112 /a.m~ (_ p.m. Requester: Phone No: 503 -sop,- 77 i SApproved per applicable aides. ElCorrections required prior to approval. COMMENTS: ��- r ry C% 1 \ nom E e. ■ <IIn`s eetor: y l�ir�'U7 1 ?� r ,i t / /REINSPECTION FE REQU RED. Prior to J paid at 6300 Southcenter Blvd., Suite 100. Date: / /2. / .zg/, Z next inspection, fee must be Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 1'Y)f2 -13. Project: Type of Inspection: Address: 177a) LOPS; VAi1FY Date Called: Special Instructions: € OA-4 06y :AXG -al Date Wanted:. i1/16117 !aim., P.m. Requester: PnL1i..._ Phone No: 97/-20S - oS cApproved per applicable codes. EiCorrections required prior to approval. COMMENTS: 1- I spector Gf-f / - 7)l�rA 644 JGc/ Date: 07/4/Z El INSPECTION FEE REQUIRED Prior to next inspection, fee must be ` aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. IPER: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -156 PROJECT NAME: UNITED RENTALS SITE ADDRESS: 17700 WEST VALLEY HY X Original Plan Submittal Response to Incomplete Letter # DATE: 10 -05 -12 Response to Correction Letter # Revision # After Permit Issued DEPARTMEN S: Bung ivision Public Works ❑ Aw' fi/A Fire Prevention Structural El Planning Division Permit Coordinator u DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-09-12 Complete Incomplete n Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11 -06 -12 'U/ Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeopleinter Friendly Page General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MILL CREEK HEATING LLC 5037491000 Po Box 428 Aumsville OR 97325 Out Of State Limited Liability Company UBI No. 603216609 Status Active License No. MILLCCH888MR License Type Construction Contractor Effective Date 8/3/2012 Expiration Date 8/3/2014 Suspend Date Specialty 1 General Specialty 2 Unused Business Owner Information Name Rote Effective Date Expiration Date MIX, TOBY JEROLD Partner /Member 07/19/2012 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 Western Surety Co 71304505 07/26/2012 Until Cancelled $12,000.00 08/03/2012 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 Austin Mutual Ins Co BP1729180 09/15/2011 09/15/2013 $1,000,000.00 08/09/2012 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 11/14/2012 - RAFTERS s General Notes THESE NOTES APPLY TO MECHANICAL DRAWINGS UNLESS NOTED OTHERWISE 1. DETERMINE LENGTH OF PIPE BELOW ELBOW PER APPLICATION OF HOSE. ROUTE DOWN —PIPE BETWEEN CRANE RAILS. 2. DETERMINE HANGER LENGTH PER STATION REQUIREMENTS 3. AERO — MOTIVE TORQUE REEL #130176004 4. HANGER SLING [USUALLY HUNG AT 12 FT POINT.] ADJUST AS NEEDED AT STATION S.PROVIDE HEAVY DUTY GATE DAMPER. (SET SCREW) 6. PROVIDE CAR —MON CTA TAILPIPE ADAPTER WITH CLAMP. USE PULL —DOWN POSITIONING POLE IF REQUIRED TO REACH. 7. FLEXHAUST BDS HIGH TEMP HOSE PROJECT SCOPE A— Replace 1 large worn out rooftop exhaust fan with 2 small high static exhaust fans. B— Split existing exhaust duct system into 2 halves. C — Add 3 new stations D— Upgrade 5 existing stations with new hoses and torque reels E— Add 4 remote starter switches for convenient stop -start of fans, (wiring by electrician). RECEIVED CITY OF TUKWILA O CT 0 5 2012 PERMIT CENTER �� 3�` - ' __ - -_ J BEAM % .� - ROOF HATCH _ m 6X5 REDUCER (IFEXLSEINGPIPEIS6) � .1 a � z _ '" -- _ ��'(} -] .. 1 ;� 4 cbl 4` — �� Brr . 4) 4 SAFETY CHAIN ,'' ` NOTE Ili C.� $,r 1 6" 6° (E) i < LQ ,� o . � 0 � ,� NOTE x --� (E) . (E) -- (� NOTE 0 ! 5X4 REDUCER (NOT ® FANS ONE v ROOF o ' 6" ELECTRIC _ PANELS 6 s. — ff E E 6,r r s„ (1 5" rr }} t t - — 8" �; 1 ,l I 10" 10" --1 $u (E} 5ff (N ) o -- — -- Y — 8„ E Err NOTE co 1 (N) = NEW (E) = EXISTING :, d- *% 4R;914. NOTE ! N` E © -- -- MINIMUM MOUNTING HEIGHT [EXAMPLE DIMS} [EXA D 1 .. REVIEWED FOR v CODE COMPLIANCE APPROVED - - -- OCT 3 0 A"3- City of Tukwila BUILDING DIVISION No. Revision /Issue Date srARm EX: SQ. o �36 EF1 Firm Name and Address MILL CREEK HEATING LLC 503.749.1 ooa FAX: 5 ©3.743.2469 LI i.. . - START 2 PARAV.ry_A37RCX� KGWNGER6EVI START CREEK PO BOX 428 AUMSVILLE, OR 97325 g t Tea (HEATING N BAYSTOP r an WWW.MILLCREEKHTG_COM ,7��// FELE COPY %� STOP Project Name and Address UNITED RENTALS 17700 WEST VALLEY HWY TUKWILA, WA 7031 /� 4ir s} 251-8150 EQUIPVE \T SCHEDULE PerrIt Ph' r <': approval la BtNP3���}� omissions. t, 0t coni Wction documents Yobs not oU (f ze START —.— MINK MANUFACTURER YODEL / Description HOR POYER PET u MGM' OW ELECTRICAL CHARAC1ERISTICS YsltsAblph H Y "U) MP T CAPACITY EF1 DAYTON 7C568 HI -PRESS EXH FAN 1848 CFM @ 1.5" 1.5 HP 75.42 460 3P 15 A 2.2 fla 1 :Jon 3i any code ' ordnance. ReCGOt EF2 DAYTON 7C568 HI -PRESS EXH FAN 1848CFM @1.5" 1.5 HP 75.42 46o3PR 15 A 2.2 FLA y .1 ►� ��'_, ;, r+,1 ..� ' ,. ' - °' �• i�•+ii� J� FF / ^` SEIMENS 50CA3DE START SW/ ST. RT KAAROGER6ORR71 START itiSTAEM -STOP l �, If / EF2 AV —, .• • By I V' /z 21 3 START SEPARATE PERMIT REQUIRED FOR: Q Mein t erilectrical Gies Piping City of Tukwila Et. LDING DIVISION Date. /1-1 STOP OVER -, PM6 SAY4 r . > �f Ti�kvvil� DIVISION Project TAILPIPE EXHAUST SYST- Sheet • C MOTOR `OAS 7xERnuu WIRING DIAGRAM „ REViSIONS BUILDING � No changes shalt be made to the scope cf work without prior approval of Tuic.vv'ta Building Division. 1��. `^ MT:: � .�, ,,: -i;, will require a new plan submittal �i r,rc:'y in ;!u e add Bona! p,an revisl,! f ss. y I 2 3 1 Z Date 9/27/20 LINE DIAGRAM Scale 1 8 SCALE 1 WIRING BY ELECTRICIAN UNDER SEPERATE PERMIT til - Ed Gates