Loading...
HomeMy WebLinkAboutPermit M12-162 - WOWRACK TECHNOLOGIESWOW TECHNOLOGIES 12201 TUKWILA INTERNATIONAL BL EXPIRED 06-08-13 M12 -162 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206.431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0923049120 Address: 12201 TUKWILA INTERNATIONAL BL TIIKW Project Name: WOW TECHNOLOGIES Permit Number: M12 -162 Issue Date: 12/10/2012 Permit Expires On: 06/08/2013 Owner: Name: INTERNATIONAL GATEWAY WEST Address: 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA 98168 Contact Person: Name: JIMMY PANDRA Phone: 206 - 890 -8080 Address: 12201 TUKWILA INTERNATIONSAL BL, SUITE 110 , TUKWILA WA 98168 Email: JIM @WOWRACK.COM Contractor: Name: VITAL MECHANICAL SERVICE INC Address: 14630 SE 213 ST , KENT WA 98042 Contractor License No: VITALMS964MM Phone: Expiration Date: 09/26/2014 DESCRIPTION OF WORK: INSTALL ADDITIONAL 100 -TON CHILLER AND CRAH UNIT IN EXISTING DATA CENTER SPACE Value of Mechanical: $70,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Fees Collected: $1,002.06 International Mechanical Code Edition: 2009 The granting of this permit does not p construction or the performance of wor -back of this permit. xaxtu with, Signature: Print Name: sum Date: d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. to give authority to violate or cancel the provisions of any other state or local laws regulating i authorized to sign and obtain this mechanical permit and agree to the conditions on the -0/VL- vvi vvvi re\ Date: 17-(1 o/ 20 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. r1nr. IMC -4/1 n M19-169 Printprl• 19 -16 -7019 • • PERMIT CONDITIONS Permit No. M12 -162 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 6: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 7: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDMONS * ** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 17: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 18: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) ann. IMC -4/1(1 M17 -1R2 PrintArl• 17- 1(1 -7n17 19: Duct smoke detectors shall be le of being reset from a single point near t,arm panel. (City Ordinance #2328) 20: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 21: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. rinn' IM[: -4 /1(1 M17-167 Printarl• 17 -1(1 -2017 CITY OF TUKWIld: Community Developmeirepartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwiIaWA.ov Mechanical PWit No MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: 122'0 • 41.5:39.....'", -•• • King Co Assessor's Tax No.: Tenant Name: )C ,, I. inowgRO;OWNE4,::::'-'• Name: 5,51 k Address: 1-1:10 I i--A.■A.511 o. /4— OVA 41- L(00 City: 4 0Li L State: L,t6c_ Zip:5 ot6s CONTAGT,PERSPN00-soirreCeiyingall:,15rojetl.::,.:,..: doiiiiiiiiiii*410.::i';':':`'.;±.:;,::::'..:`-:::.1.!: Name: ) rvl tri. ■-) Pa in.Olt re \ Address: Address:41_01 kuL,st I„ f„,4— 12 (v6( * 1(0 City: t 0 1 to,. State: biA_ Zip: ogi,6s) Phone: 2,0 t, ... g00R0 Fax: Email: )- -,,,,, e wo LA) (-a ce, . co Phone: m2_9)014 -g 120 Suite Number: 11 0 Floor: New Tenant: 0 Yes R.. No ,.111ECHANICik.VONTRACTOR .11‘,WORMAtIOW;r:;':`. - :::" - Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: 4,5 Valuation of project (contractor's bid price): $ 4-1)/ 0°D Describe the scope of work in detail: '(r c)di'ki 0 v\ cAt ef ok c-ev,4er (00+3, c_Li(- Ct-A-t ut'+ `in Use: Residential: New E Replacement Commercial: New Replacement Fuel Type: Electric El Gas LJ Other: HAApplicationsWorms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu t Floor furnace Suspended /wall /floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm t Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNEJOR UTHORIZED AGENT: Signature: G/ V J Print Name: S' V tvl 7C�tiP f" Mailing Address: 1-2 11-)( {U�wc (e, I hi- I(•6` *1(0 Date: tD / /b /20 1- Day Telephone: t��C r GQv go H:\Applications\Forms- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11 docx Revised August 2011 bh City State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0923049120 Permit Number: M12 -162 Address: 12201 TUI{WILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 10/16/2012 Applicant: WOW TECHNOLOGIES Issue Date: Receipt No.: R12 -02873 Initials: User ID: Payee: JEM 1165 Payment Amount: $1,002.06 Payment Date: 10/16/2012 01:15 PM Balance: $0.00 JIMMY PANDRA, WOW TECHNOLOGIES INC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 05126G ACCOUNT ITEM LIST: Description 1,002.06 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 801.65 000.345.830 200.41 Total: $1,002.06 doc: Receipt -06 Printed: 10 -16 -2012 05 -01 -2013 ity of Tukwila .Ilaggerton, Mayor epafimerri,of CoMmuh ty Development JackPace, Director JIMMY PANDRA 12201 TUKWILA INTERNATIONSAL BL, SUITE 110 TUKWILA WA 98168 RE: Permit No. M12 -162 WOW TECHNOLOGIES 12201 TUKWILA INTERNATIONAL BL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 06/08/2013. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 06/08/2013, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, A4t0 nnlfer Marshall Pit Technician File: Permit File No. M12 -162 000 "SO uthcenterBoulevard ,Suite #100; Tukwila, Washington 98188= Phone 206-431 -3670 Fciz206-431 -3665 ) *PERMIT COORD CON, PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -162 DATE: 10/16/12 PROJECT NAME: WOW TECHNOLOGIES SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: uilding Division Public Works ❑ Pre eve tion Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 10/18/12 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions a Not Approved (attach comments) ❑ Notation: DUE DATE: 11/15/12 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople Printer Friendly Page General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name VITAL MECHANICAL SERVICE, INC. UBI No. 602410867 Phone 2536306933 Status Active Address 13106 Se 240Th St Ste 101 License No. VITALMS964MM Suite /Apt. License Type Construction Contractor City Kent Effective Date 7/21/2004 State WA Expiration Date 9/26/2014 Zip 98031 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date ALMON, KEVIN LEWIS President 07/14/2004 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 CBIC 5G8008 05/28/2010 Until Cancelled __$1,000,000.0006 $12,000.00 05/28 /2010 2 CBIC SG8008 07/20/2006 05/28/2010 $6,000.00 07/11/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 WEST AMERICAN INS CO BKW53465203 06/06/2008 06/06/2013 __$1,000,000.0006 $1,000,000.0006/O1/2012 /01/2007 3 OOHIO CAS INS BKW53465203 06/06/2006 06/06/2008 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 12/10/2012 u 1 ruv u Engineering Services Inc 9560 Moran Road NE Bainbridge le. WA 98110 Phone: 206.842.6947 Fax 206.842.6948 LEGEND General 1. All work to conform to 2009 International Mechanical code, 2009 Uniform Plumbing Code, City of Tukwila Building Codes, and 2009 Washington State Energy Code. qui red. = c a e ou an # or sheets and WSEC forms. 3 Use sufficient journeyman workmen and competent supervisors in the execution of this work to ensure proper and adequate installation throughout. 4. Cutting, Patching, and Demolition: a. Do all cutting, patching and demolition required to install materials and systems specified and show on the drawings. b. Cutting shall be done in a neat and workman like manner limiting scope to only that which is necessary to accomplish the new work. Remove all cut material from site Patch to match existing. c. Do no cutting or drilling of structural members or slabs without permission of the Owner. d. Take precautions to protect building, contents and occupants and repair to like -new condition or replace if directed, all damage to building and their contents. 5. The Contractor shall visit site prior to submitting a bid and note all conditions affecting his work. No extras will be allowed for coordination or relocation of existing conditions not shown on the drawings. 6. Provide all racks, stands and supports for mechanical equipment and ductwork as required. Supports for piping shall isolate pipe from support. 7. The drawings are generally diagrammatic. Complete details of the building which affect the installation may not be shown. Contractor to provide complete HVAC system as shown on the drawings. Exact location of all work to be verified in the field. 8. Contractor shall be responsible for damages caused by their work and that of other trades, in the execution of their work and that of other trades, and shall make, or pay for , all necessary repairs to restore damage to like- new condition at no cost to the Owner. 9. Electrical Equipment and Wiring: Provide all control conduit and wire associated with the mechanical equipment. Install in compliance with the requirements of the electrical work. Provide complete controls shop drawing package for review. 10. Provide final as -built drawings and maintenance manuals. 11. Balancing: Balance all air outlets to within ± 10% of that shown on the drawings. Air balance to be performed by Neudorfer Engineers. 12. This 15 a 24 hour /day, 7day /week critical use facility requiring continuous operation at a constant temperature setpoint. Per WSNREG. 1412.4 Exception 1, automatic set back and optimum start controls are not required. 2c0� es completion of required cover DUCT - FIRST NUMBER 15 SIDE SHOWN Products 1. Use all means necessary to protect materials, before, during and after installation and to protect the installed work of other trades. In the event of damage, immediately make all repairs and replacements necessary to the approval of the Owner and at no additional cost to the Owner. 2. Water Piping: Type "L" copper with wrought or forged copper fittings, lead free solder. 3. DWV Piping: All VW piping to be no -hub cast iron with standard fittings or copper. 4. Sheet Metal All ductwork to be sheet metal and comply with SMACNA Ductwork Standards. - 3 "S.P. 5. Duct Insulation: See insulation table for thickness. Do riot insulate ductwork in data center. 6. Water Pipe Insulation: See insulation table for thickness. Fiberglass insulation with flame- retardant kraft paper vapor barrier. Provide Prefabricated Thermal Insulating Fitting Covers. 7. HVAC Equipment: Furnish and install HVAC as shown in the schedules located on the plans. Execution 1. Prior to any work or fabrication, carefully inspect the existing conditions and verify that all such conditions are compatible to the point where this installation may commence. provide shop drawings of all ductwork and hvac equipment for engineering review. 2. Plumbing -water piping: a. Make all joints in copper tube with lead free solder applied in strict accordance with the manufacturer's recommendations. 17. Make all pipe penetrations in walls, floors and roof water and air - tight. Provide piping supports as required by code. Install per UPC. 3. She Metal: Construction and installation of all ductwork shall comply with all SMACNA Standards (3" S.P.). 4. All ductwork shall have all transverse joints and longitudinal seams seams sealed. All ductwork shall be sealed in accordance with Standard RS -7 5. Record drawings shall be kept on site and updated daily. Provide measurement to all underground and concealed work. � wu � �•_. �w � the Washington State Code 6. All relevant requirements of- 5eotion 1416 of the Washington State Energy Code including, but not limited to, provision of record drawings & manuals, balancing, testing & commissioning shall be fully complied with. 7. Provide complete factory startup & commisioning of HVAC equipment. End of Mechanical Specifications. f f SUPPLY DUCT UP SUPPLY DUCT DOWN RETURN DUCT UP RETURN DUCT DOWN SQUARE ELBOW SQUARE ELBOW TURNING VANES RADIUS ELBOW ROUND ELBOW TURNING VANES ROUND TO RECTANGULAR TRANSITION LARGE TO SMALL TRANSITION DIRECTION OF FLOW INCLINED DROP IN DIRECTION OF AIR FLOW INCLINED RISE IN DIRECTION OF AIR FLOW VOLUME DAMPER FIRE DAMPER SMOKE DAMPER FIRE /SMOKE DAMPER MOTORIZED DAMPER ACCESS DOOR. CHILLED WATER SUPPLY CHILLED WATER RETURN CONDENSER WATER RETURN COLD WATER PIPING HOT WATER PIPING ELBOW SANITARY SEWERS VENT LINES CFM THROAT SIZE T 4 DIFUSER TYPE SEE SCHEDULE SUPPLY OUTLET CEILING DIFFUSER ARROWS INDICATE THROW DIRECTIONS THERMOSTAT ABBREVIATIONS (X) NUMBER IN PARENTHESIS INDICATES QUANTITY REVISIONS No changes shall be made to the scope at work k without prior approval of Tukwila Building Division. RoviSiens wit! require a new plan submittal and may include additional plan review fee 3. DRAWING INDEX M -1 = LEGEND AND SPECIFICATIONS' M -2 MECHANICAL FLOOR PLAN & SECTION M -3 DIAGRAMS AND SECTIONS M -4 = SCHEDULES 0-1 OR 0— . ELBOW UP GI— OR C ELBOW DOWN OR -- TEE IEV -104- OR -0-- TEE UP City BUILD TEE DOWN —E-- FLOW DIRECTION PIPE PITCH UP OR DOWN. *1- GATE VALVE. - CHECK VALVE. -- BALL VALVE --Do-- 2 -WAY VALVE. " 2 -WAY AUTOMATIC OR UP /DN CONTROL VALVE. UNION STRAINER. VIEWED FOR CODE COMPLIANCE APPROVED OCT 3 0 2012 PRESSURE GAGE W/ SHUT -OFF VALVE THERMOMETER. DATE ISSUED: 2/19/2010 FOR CONSTRUCTION REVISIONS: A\ 6/7/2010 FOR CONSTRUCTION /1\ 3/2412011 - CHILLER REVISIONS © 712/2012 - CHILLERICRAC ADD FILE CCIFY M�ti-1la` METER. Permit Ho. Plan rsview approval is subject to errors and omiselnfts, 2roval of construction documents doss no, the violation of any adopted code or ordinartc,.. Fis';31 of approved FielCCop and conditions is acimowisc .1: SEPARATE PERMIT REQUIRED FOR: i Mechanical . Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION By Date:. h./to (2oIZ SHEET CONTENTS: MECHANICAL LEGEND AND SPECIFICATIONS City Of Ti.ikwib BUILDING DiViS;),ON RECEIVED c1T ` OF Tilkw t. !. _ OCT 16 2012 PERMIT CENTER SHEET NUMBER: ,U1\'2 -�1� COPYRIGHT © 2012 by HUNT ENGINEERING SERVICES Inc. FAN WALL X01 (FOR CRAC -1 i .11.11,... ,__ »»�.»a._,_.. ,_::�.:: -:::: �:::::z � �:: ::::::::: : :::::::..::::::::w... :111:1. Engineering Services Inc. 9560 Moran Road NE Bainbridge le, WA 98110 Phone. 206.842.8947 Fa= 206.842.6948 CHECK VALVE (1Y12.) RF -1 & RF -2 16x24 48x24 FUTURE CRAC -4 FUTURE LOUVER FLEX PIPE CONNECTION (TYP.) CIRCULATION PUMP (TYP.) TO CIRC PUMPS CP -1 & CP -2 CHAR FROM CRAC UNITS PRE FILTER (SEE SECTION) NOTE: NEW PUMPING SYSTEM 700 NOTES: (TYP.10) 28x24 48x24 —\ LV -6 / CD -5 �1t •�f�'�a A` aa`" / f'� {f °` }�•f/ { /f C f Ff ` {/ / Jf /{ �` f F`' Sc' .. / ,i �„, '{ / j % °'' ..f , Sy % '{ i1. +.r : �h ��+v 'a { {{; f { {i. 3° fj e° 2::/ /.' ��r _ ;' 3 RUNOUTS TO CRAC' 1 CRAC -2 LV -5 / CD -4 PLENUM ACCESS PANEL PIPE SUPPORT CIRCULATION PUMP DIAGRAM L fff:`� A` f f f t f+ / }:/ 1 i 48x24 .. / ,i �„, PRE FILTER City of Tukwila BUILDING DIVISION NPW TERMINATED IN JANITOR CLOSET. SEE PIPING DIAGRAM FOR ADDITIONAL INFORMATION. 1 -1/4" CONDENSATE DRAIN FAN WALL PRESSURE SENSOR 60x24 DUCT, 5.O, D. 9'- LV -2 / CD -2 CRAC -1 LV -1 / CD -1 PLENUM ACCESS PANEL GENERAL NOTE: ALL EQUIPMENT, DUCTWORK, ETC. ON PLAN IS EXISTING UNLESS OTHERWISE NOTED. AREAS OF NEW WORK ARE CLOUDED. O N N 3" RUNOUTS TO CRAC •7►501111• O'►Z.R• EXIST. LOUVER W/ METAL COVER ON TH I P FOR EMERGENCY USE) 600 (TYP. 5) ROLLER TYPE PIPE SUPPORT W/ TOP AND BOTTOM SUPPORT -I � SEE PIPING DIAGRAM FOR ADDITIONAL DETAILS OF N.P.W. AND PUMPED CONDENSATE DRAIN. F L. 22x24 (NEW) DUCTWORK CONNECTION FROM CRAC TO HEADER (TYP. 3) (NEW) CRAC -3 (NEW) LV -8 / CD -7 38x24 (NEW) LV -7 / CD -6 (NEW) PRE FILTER (SEE SECTION A) CHILLER AND ASSOCIATED EQUIPMENT & PIPING IS 1 FLOOR BELOW DATA CENTER ON OUTDOOR DRIVE APPROACH TO PARKING GARAGE. (NEW) 3" RUNOUTS TO CRAC -3 SEAL NEW LOUVER WITH NEW SHEET METAL BLANK -OFF PLATE NEW) PLENUM ACCESS PANEL THIS SECTION OF EQUIPMENT SCREENING 15 REMOVABLE TO PERMIT MAINTENANCE ON CHILLERS) BOLLARD (TYP.) EXISTING SCREEN \. ROLLER TYPE PIPE SUPPORT, BOTTOM ROLLER ONLY ya HUNT ENG. JOB #: DATE ISSUED: 2/19/2010 FOR CONSTRUCTION REVISIONS: / \ 31212010 FUTURE DUCT LAYOUT 31812010 - HYDR. PIPING REVISIONS / s\ 61712010 - FOR CONSTRUCTION /4\ 3124/2011 - CHILLER REVISIONS Q 71212012 - CHILLER/CRAC ADD -r- 111:1 , . . . 8" BLK STEEL CHILLED WATER SUPPLY AND RETURN PIPE pry. CP-4 (NEW) BOLLARD (ON FLOOR BELOW) CHWS PIPING CONNECTION SHEET CONTENTS: MECHANICAL FLOOR PLAN & SECTION DOWN T01ST FLOOR (TYP.) ME HANICAL PLAN SCALE:14" =1' - 0" CIRC. PUMP CP -1 (UNDER CHILLER - TYP. EXPANSION TANK ET -1 MAINTENANCE ..a CLEARANCE ,' CLEARANCE FOR PIPING I 0 1 2 4 SCALE 1/4 " =1-0" * /.{..r ,* (NEW) CHILLER CH -2 , (NEW) CIRC. PUMP CP -3 (UNDER CHILLER - TYP.) SHEET NUMBER: � ......... ====.: '` $::n)F' ? EiRVEMEM VA 3TA:J V °: 4 Q'.'w.'DC.i . h`S:\ : ;k '..Re)MM .Mw'Sxon'u�tw:a Rini- t0 art OF TUI'<Vr,!1 P OCT' 162012 PERMIT CENTER M -2 2 OF 4 COPYRIGHT © 2012 by HUNT ENGINEERING SERVICES Inc. �3 { f f 34x24 ,1 1 i 48x24 .. / PRE FILTER City of Tukwila BUILDING DIVISION NPW TERMINATED IN JANITOR CLOSET. SEE PIPING DIAGRAM FOR ADDITIONAL INFORMATION. 1 -1/4" CONDENSATE DRAIN FAN WALL PRESSURE SENSOR 60x24 DUCT, 5.O, D. 9'- LV -2 / CD -2 CRAC -1 LV -1 / CD -1 PLENUM ACCESS PANEL GENERAL NOTE: ALL EQUIPMENT, DUCTWORK, ETC. ON PLAN IS EXISTING UNLESS OTHERWISE NOTED. AREAS OF NEW WORK ARE CLOUDED. O N N 3" RUNOUTS TO CRAC •7►501111• O'►Z.R• EXIST. LOUVER W/ METAL COVER ON TH I P FOR EMERGENCY USE) 600 (TYP. 5) ROLLER TYPE PIPE SUPPORT W/ TOP AND BOTTOM SUPPORT -I � SEE PIPING DIAGRAM FOR ADDITIONAL DETAILS OF N.P.W. AND PUMPED CONDENSATE DRAIN. F L. 22x24 (NEW) DUCTWORK CONNECTION FROM CRAC TO HEADER (TYP. 3) (NEW) CRAC -3 (NEW) LV -8 / CD -7 38x24 (NEW) LV -7 / CD -6 (NEW) PRE FILTER (SEE SECTION A) CHILLER AND ASSOCIATED EQUIPMENT & PIPING IS 1 FLOOR BELOW DATA CENTER ON OUTDOOR DRIVE APPROACH TO PARKING GARAGE. (NEW) 3" RUNOUTS TO CRAC -3 SEAL NEW LOUVER WITH NEW SHEET METAL BLANK -OFF PLATE NEW) PLENUM ACCESS PANEL THIS SECTION OF EQUIPMENT SCREENING 15 REMOVABLE TO PERMIT MAINTENANCE ON CHILLERS) BOLLARD (TYP.) EXISTING SCREEN \. ROLLER TYPE PIPE SUPPORT, BOTTOM ROLLER ONLY ya HUNT ENG. JOB #: DATE ISSUED: 2/19/2010 FOR CONSTRUCTION REVISIONS: / \ 31212010 FUTURE DUCT LAYOUT 31812010 - HYDR. PIPING REVISIONS / s\ 61712010 - FOR CONSTRUCTION /4\ 3124/2011 - CHILLER REVISIONS Q 71212012 - CHILLER/CRAC ADD -r- 111:1 , . . . 8" BLK STEEL CHILLED WATER SUPPLY AND RETURN PIPE pry. CP-4 (NEW) BOLLARD (ON FLOOR BELOW) CHWS PIPING CONNECTION SHEET CONTENTS: MECHANICAL FLOOR PLAN & SECTION DOWN T01ST FLOOR (TYP.) ME HANICAL PLAN SCALE:14" =1' - 0" CIRC. PUMP CP -1 (UNDER CHILLER - TYP. EXPANSION TANK ET -1 MAINTENANCE ..a CLEARANCE ,' CLEARANCE FOR PIPING I 0 1 2 4 SCALE 1/4 " =1-0" * /.{..r ,* (NEW) CHILLER CH -2 , (NEW) CIRC. PUMP CP -3 (UNDER CHILLER - TYP.) SHEET NUMBER: � ......... ====.: '` $::n)F' ? EiRVEMEM VA 3TA:J V °: 4 Q'.'w.'DC.i . h`S:\ : ;k '..Re)MM .Mw'Sxon'u�tw:a Rini- t0 art OF TUI'<Vr,!1 P OCT' 162012 PERMIT CENTER M -2 2 OF 4 COPYRIGHT © 2012 by HUNT ENGINEERING SERVICES Inc. JANITOR ROOM. 3/4" DOMESTIC WATER r- I 3/4" NON POTABLE WATER 3/4" NPW 3/4" 1-1/4" PUMPED CONDENSATE 11 -- 17 CRAC-2 1 J L DRAIN TO BACK OF MOP SINK 7 CRAG -1 CRAG UNIT TO HAVE FACTORY 17 3 -WAY VALVE. J NOTE: CRAG 3 IS A REDUNDANT UNIT. SET T -STAT HIGHER THAN OTHER UNITS 1 -1/4" CRAC -3 `12 C 12 " 3" 15 13 30 P51 11 18 18 11 11 N.C. N.0 ak BY -PASS SET FOR 110 GPM 8" CHILLED WATER HEADER` FOR FUTURE EXPANSION 13'- 8 -1/2" ANGLE SUPPORT BRACE EXISTING CEILING & TILE TO BE REMOVED 9' -0" EXISTING 60x24 HEADER DOD - RUSKIN BD6 FLEX CONNECTION EXISTING 8" BLK STEEL CHWS & CHINK CRAG -3 BAR JOIST (TYP). EXISTING PIPE SUPPORTS I BEAM USE BACK OF HEADER FOR PLENUM SIDE RETURN PLENUM WIDTH OF CRAG UNIT VESDA OR DUCT DETECTORS. CONNECT FOR UNIT SHUT DOWN (BY OTHERS) RETURN PLENUM DIVIDER (2) VAPOR TIGHT LIGHTS W/ PILOT LIGHTED SWITCH ON EXTERIOR OF PLENUM (BY E.C.) LOUVER CONTROL DAMPER PRE FILTER 20 "x60" ACCESS PANEL REPLACE (E) WINDOW W/ LOUVER/DAMPER/ FILTER ASSEMBLY SEE DETAIL FINAL FILTER. CUSTOM FILTER FRAME 4" DEEP 65% FILTER. NOTE: ALL EQUIPMENT, MATERIAL & WORK 15 NEW UNLESS OTHERWISE NOTED. C ASSEMBLY SECTION SCALE: 1/2 " =1' -0" STRUCTURAL STAND FOR CRAG UNIT 0 6" 1 2 SCALE 1/2 " =1-0" II SEE 'CIRCULATION PUMP DIAGRAM', DWG. M -2 FOR ADDITIONAL WORK & REQUIREMENTS. 14 AS -1 ,2 AV -1 17 - 3/4" N.C. 12 CP -4 _ 12 6 12 12 3/4" CP -3 2 ET -1 12 12 12 12 5 6 n 11 N.C. 15 2 U 11 CHILLER PIPING DIAGRAM SCALE: NONE LOUVER BLANK CONTROL DAMPER REDUCE CONTROL DAMPER SIZE TO ACCOMMODATE ACTUATOR AS REQUIRED ACTUATOR 10 N.O. 12 NOTE: CH -2 IS FOR REDUNDANCY ONLY. ISOLATION VALVES FOR CHILLED WATER NOT USED ARE OFF. MANUAL SWITCH OVER IS REQUIRED FOR BACK -UP CHILLER OPERATION REVIEWED FOR CODE COMPLIANCE APPROVED OCT 3 0 2012 City of Tukwila BUILDING DIVISION LEGEND 1. STRAINER/BLOW DOWN VALVE 2. EXPANSION TANK 3. PUMP 4. NOT USED 5. AIR' VENT CONNECTION PORT 6. PRESSURE/ TEMPERATURE ACCESS PORT 7. HEAT EXCHANGER 8.: FLOW SWITCH 9. BALANCE VALVE /DRAIN PLUG ' 10. PRESSURE RELIEF 11. ISOLATION VALVES 12. FLEX CONNECTIONS 13. PRESSURE REDUCING /FILL VALVE 14. AIR SEPARATOR AND VENT 15. CIRCUIT SETTER 16. NOT USED 17. CHECK VALVE 1 &. STRAINER GENERAL NOTES 1. THE CHILLER SHALL HAVE A FACTORY CONTROLS SYSTEM WHICH SHALL PROVIDE A COMPLETE CONTROLS SYSTEM FOR THE CHILLER AND CHILLED WATER SYSTEM. 2. CHILLED WATER SYSTEM SHALL BE 30% PROPYLENE GLYCOL 3. REDUCED PRESSURE BACKFLOW PREVENTOR SHALL BE APPROVED BY WASHINGTON STATE DEPT. OF HEALTH. 4. ALL PIPING ABOVE 3" SHALL BE SCHEDULE 40 BLACK STEEL W/ WELDED OR VICTAULIC FITTINGS. 5. ALL LINEWORK SHOWN LIGHT 15 ALREADY INSTALLED. LINEWORK SHOWN BOLD 15 NEW. WALL LOUVER ELEVATION B SCALE: NONE RUSKIN CD 40 THINLINE CONTROL DAMPER ACCOMMODATE OUTBOARD JACK SHAFT RUSKIN L375D 2" DEEP 30% FILTER PLEATED POWER WIRING; 2 DISC. SW, 2 MOTOR CONNECTIONS, BY E.C. PRESSURE SENSOR TO V.S.D. CONTROL FANS TO +.02" S.P. COMPUTER ROOM 'POSITIVE TO BUILDING CORRIDOR lt I Lp POWER BY E.C. -J FUSED DISC. BY E.C. MD-1 RF -1 MD-2 CONTROL BY M.C. –� RF -2 0 �- DIGITAL OUT FROM V.F.D TO OPEN DAMPER ON FAN OPERATION V.F.D. BY M.C. DIGITAL INPUT TO TURN OFF FAN WHEN CRAC AIR ECONOMIZER 15 LOCKED OUT. MODULATING SPRING. OPEN POWER CLOSE MOTORIZED DAMPER. OVERSIZE V.F.D. TO SUPPORT NOTE: FOR REFERENCE ONLY. THIS CONTROL SYSTEM HAS BEEN INSTALLED IN A PREVIOUS PROJECT. FAN WALL CONTROL DIAGRAM SCALE: N.T.S. REC6VED CITY OF TUKVVit ..A OCT' 16 2012 PERMIT CENTER 1 Engineering' Services Inc. 9580 Moran Road NE Bainbridge Isa, WA 98110 Phone: 206.842.6947 Fax 206.842.6948 HUNT ENG. JOB #: HUNT # DATE ISSUED: 2/19/2010 FOR CONSTRUCTION REVISIONS: A 6/7/2010 FOR CONSTRUCTION A 312412011 - CHILLER REVISIONS 71212012 - CHILLER/CRAC ADD A A A SHEET CONTENTS:. MECHANICAL DIAGRAMS AND SECTIONS SHEET NUMBER: M -3 3 OF 4 COPYRIGHT © 2012. by HUNT ENGINEERING SERVICES Inc. E C R C SCHEDULE MARK MANUFACTURER /MODEL COOLING CAPACITY * FAN DATA CONNECTION SIZES ELECTRICAL DATA Compressors PHYSICAL DMA NOTES NOMINAL TONS TOTAL MBH (MBH) SENSIBLE (MBH) ( ) GPM PRESS. DROP (ft. H2O ( H20) CFM HP E.S.P. S, (in.) ( ) CHILLED WATER (in. '. O D. ( Cu) � CONDENSATE (in. FP ( T) HUMIDIFIER (in. O.D. ( Cu) ) VOLTS /PHASE FLA MCA MOP LENGTH (in.) ( ) WIDTH �n. ( ) HEIGa•IT m (i WEIGHT lbs. (lbs.) CRAC -1 LIEBERT / CW114- U- C -V -A -3 45 541 412 110 4 7 17,000 � 20 D 1.75 - 2 5/8 - 1 1/4 1/4 480 1 30 77.7 97.1 110 122. 34 7EA 2100 SEE NOTES CRAG- %E- / «.M 4- -C- - - -3 45 10 NOTE 1 1800 47 17,000 20 1.75 2 -5/8 1 -1/4 1/4 480130 77.7 97.1 110 2 34 7E •0 EE NOTES 3 3 9 -1/2 250 85 A5 175 60x60 NOTE 4, 6 2, 3 NOTES: .05 A ■ ■ ■ 1. PUMPS CP -1 & CP -2 HAVE BEEN (STALLED IN EARLIER PHASE OF PROJECT. 2. NEW PUMP TO MATCH INSTALLED PUMPS CP -1 & CP -2. 3. PROVIDE COMPLETE MOTOR RATED FOR VSD. ` -_. � _ _ _ - - III. A, ` _ A,. _ AIIIMI ■ . NOTE 4, 6 CD -6 RUSKIN / CD 40 THIN LINE 05A .05 -- 60x60 NOTE 4, 6 1,2,3,4,6,7,8 CRAG -3 LIEBER7 / CW114- U- C -V -A -3 45 541 412 110 47 17,000 20 1.75 2 -5/8 1 -1/4 1/4 480 / 30 27.0 33.8 60 122 34 7F 2100 AND ICOM 93.6 95.0 94.5 93.6 95.4 95.4 100 i 95.4 ;_ 95.0 94.1 95.4 , 95.0 125 94.1; 95.4 95.0 95.0 95.4 95.0 150 PACKAGE GENERAL NOTES: 95.4 * COOLING CAPACITY 0 72 °F DB, 60°F WB, 50% RH) #* UNITS CRAC -1& CRAC -2 ARE ALREADY INSTALLED. CRAC-3 15 NEW NOTES: 95.0 1. PROVIDE UNIT DISCONNECTS. 2. PROVIDE WITH CONDENSATE PUMPS. 3. PROVIDE WITH REAR MOUNTED RET U RN W/ CUSTOM FILTER RETURN SEE "AC ASSEMBLY SECTION". 4. PROVIDE INTERLOCK & CONTROLS FOR 100 %MODULATION AIRSIDE ECONOMIZER OPERATION. 5. ELECTRIC REHEAT, INFRARED HUMIDIFIER, L I EBE RT ICOM CONTROLLER. 6. CONDENSATE PUMP (REPLACE FACTORY CHECK VALVE W/ HIGH QUALITY BRASS CHECK VALVE). 7. PROVIDE DRIP PAN FOR ENTIRE UNIT, 1" LIP. 8. PROVIDE SNMP ERROR REPORTING. Chiller Schedule Mark Description Model Location EER IPLV Compressors Refridge -n C' e, Water Electrical Size LxWxHt NOTES volts /phase Flow LW % Propylene MCA MOP Notes CH -1 Carrier Aquasnap Air Cooled Scroll Chiller Package System 3ORBA1006 -0 -3 Skid Mount on Ground 9.6 13.6 460/3 R-410 L 220 GPM 46 30% 209.2 250 142 "x89 "x 90" Unit weight is approx. 6,200 lbs. A weighted sound pressure level: CH -2 Carrier Aquasnap Air Cooled Scroll Chiller Package System 30RBX1 0065 -L1 - -3 Skid Mount on Ground 9.6 13.6 460/3 R-410 A 220 GPM 46 30% 209.2 250 142 "x89 "x 90" Unit weight is approx. 6,200 lbs. A weighted sound pressure level: 66dB NOTES: 1. Verify SCCR rating w/ electrical prior to order. 2. Unit mounted disconnect. 3. Storage tank - Chilled water 4. Unit mounted controls for complete chilled water loop control (including pumps), provide SNMP module for alarm outputs. 5. Skid mount unit w/ security grilles and hail guards. 6. GFI outlet. 7. Digital compressor control. 8. Provide vibration isolation pads. EXHAUST FAN SCHEDULE MARK MODEL / DESCRIPTION CFM SP (in -) RPM BHP HP dBA VOLTS PHASE WT (lbs.) NOTES RF -1 GREENHECK 5BE -3L48 -100 / 510E WALL BELT DRIVE EXHAUST FAN 36,000 .375 1725 80 10.0 80 480 3 480 NOTE 1 RF -2 GREENHECK SBE -3L48 -100 / SIDE WALL BELT DRIVE EXHAUST FAN 36,000 .375 1725 8.0 10.0 80 480 3 480 NOTE 1 NOTES: FOR V.S.D. CONTROL, 1.25 5.F. VE1D RATED FOR 10 HP (SIZED FOR FUTURE). PROVIDE DAN F055 OR ABB DRIVE. -100 FAN 0 12,000 CFM OPERATES 0 6261BA, 5E2 -24 -615 PREVIOUS 8,500 CFM FANS WERE 85 dBA. 1. RATE MOTOR 2. PROVIDE 3. SBE -3L48 PUMP SCHEDULE MARK DESCRIPTION MAKE/MODEL BODY MAT'L HP BHP (Q DESIGN CONDITION) RPM PIPING CONNECTIONS (in.) IMPELLER (in.) FLOW (gPm) HEAD (ft.) MAX. OP. TEMP. ( °F) X. MAX . PRESS. (psig) WEIGHT (lbs.) NOTES INLET OUTLET CP -1 BASE MOUNTED END SUCTION HORIZONTAL PUMP BELL & GOSSETT /1510 2.555 9.5 BF IRON 10 60x60 1800 3 3 9 -1/2 250 85 NOTE 2 175 RUSKIN / L3750 / 05A 1 CP- BASE MOUNTED END SUCTION 0 L MP BELL & GOSSETT 1 1510 2 5134 9.5 BF IRON 10 RUSKIN / L375D / OSA 1800 12.77 60x60 • - 2 250 85 08 175 60x60 1 CP -3 BASE MOUNTED END SUCTION HORIZONTAL PUMP BELL & GOSSETT / 1510 2.558 95 BF IRON 10 NOTE 1 1800 3 3 9 -1/2 250 85 CD -2 175 06 2, 3 CP -4 BASE MOUNTED END SUCTION HORIZONTAL PUMP BELL & GOSSETT / 1510 2.555 95 BF IRON 10 92.4 1800 3 3 9 -1/2 250 85 A5 175 60x60 NOTE 4, 6 2, 3 NOTES: .05 A ■ ■ ■ 1. PUMPS CP -1 & CP -2 HAVE BEEN (STALLED IN EARLIER PHASE OF PROJECT. 2. NEW PUMP TO MATCH INSTALLED PUMPS CP -1 & CP -2. 3. PROVIDE COMPLETE MOTOR RATED FOR VSD. ` -_. � _ _ _ - - III. A, ` _ A,. _ AIIIMI ■ . PIPE INSULATION SCHEDULE PIPE APPLICATION NOMINAL PIPE SIZE INSULATION TYPE NOTES < 1" 1 TO <1 -1/2" 1- 1/2 "TO< 4„ 4 TO < 8 " " INSULATION THICKNESS (in.) CHILLED WATER, SUPPLY 1 1 -1/2 1 -1/2 2 CLOSED CELL FOAM WITH KRAFT PAPER JACKET 12.77 CHILLED WATER, RETURN 1 1 1 -1/2 1 -1/2 CLOSED` CELL FOAM WITH ALUMINUM COVER 60x60 NOTES: LV -4 GREENHECK / EAH690 / OSA REVIEWED FOR CODE COMPLIANCE APPROVED OCT 3 0 2012 City of Tukwila BUILDING DIVISION DIFFUSER & GRILLE SCHEDULE PLAN CALLOUT DESCRIPTION FAURER NU- MODEL NOTES A NOT USED 12.77 60x60 NOTE 1 5 COLD AISLE SUPPLY DIFFUSER .08 12.77 60x60 GENERAL NOTES: LV -3 * SEE PLANS FOR NECK SIZE. DAMPER SCHEDULE MARK MANUFACTURER / MODEL / LOCATION S. p. (in.) FREE AREA (sq. ft,) SIZE (NOTE 3) (w" x h ") NOTES LV -1 RUSKIN / L375D / OSA .08 12.77 60x60 NOTE 1 LV -2 RUSKIN / L375D/ 0 5A .08 12.77 60x60 NOTE 1 LV -3 GREENHECK / EAH690 / 05A .04 24 60x60 NOTE 2 LV -4 GREENHECK / EAH690 / OSA .O4 24 60x60 NOTE 2 LV -5 RUSKIN / L3750 / 05A .088 875 12.77 60x60 NOTE 1 LV -6 RUSKIN / L375D / OSA .08 12.77 60x60 NOTE 1 LV -7 RUSKIN / L3750 / OSA 08 12.77 60x60 NOTE 1 LV -8 RUSKIN / L37517 / OSA .08 12.77 60x60 NOTE 1 CD -1 RUSKIN / CD 40 THIN LINE / 05A 0� -" 60x60 NOTE 4, 6 CD -2 RUSKIN / CD 40 THIN LINE / OSA 06 91.0 15 60x60 NOTE 4, 6 C D- 3 RUSKIN / CD 40 THIN LINE / RETURN AIR 92.4 911 120x24 NOTE 7 CD -4 RUSKIN / CD 40 THIN LINE / OSA A5 93.0 60x60 NOTE 4, 6 CD -5 RUSKIN / CD 40 THIN LINE / 05A .05 -- 60x60 NOTE 4, 6 CD -6 RUSKIN / CD 40 THIN LINE 05A .05 -- 60x60 NOTE 4, 6 CD -7 RUSKIN / CD 40 THIN LINE 05A .05 -- 60x60 NOTE 4, 6 MANUAL BALANCE DAMPER RUSKIN / CD 4 .05 -- SIZE PER LOCATION ON PLAN NOTE 5 B.D.D. RUSKIN / BD 6 05 -- SIZE PER LOCATION ON PLAN -- NOTES: 1. PROVIDE WITH 1/4" BIRD SCREEN. 2. MOTORIZED LOUVER W/ SEAL TO MEET W.S.E.C. 3. COORDINATE EXACT SIZE WITH MULLIONS ON EXISTING WINDOWS IN AREA OF INSTALLATION. 4. SEAL TO MEET W.S.E.C. 5. PROVIDE CRANK ARM AND HAND QUADRANT. 6. REDUCE SIZE IF REQUIRED FOR MOTORIZED ACTUATOR INSTALLATION. 7. PROVIDE MULTIPLE UNITS AS REQUIRED.' MISCELLANEOUS EQUIPMENT SCHEDULE MARK DESCRIPTION MANUFACTURER / MODEL WT (Ibs•) NOTES AS -1 AIR SEPARATOR ARMSTRONG / VA5 -4 1,800 1200 AV -1 AUTO AIR VENT ARMSTRONG / AUTO AIR VENT #71 HP Efficiency (7) ET -1 EXPANSION TANK ARMSTRONG AX -60V 855 825 CIRCUIT SETTER BALANCE VALVE ARMSTRONG / CBX 1.5 84.0 SC -1 HORIZONTAL, EXTRUDED ALUMINUM, 8'H LOUVERED EQUIPMENT SCREEN RELIABLE I445RBI 86.5 1 SC -2 SIMILAR TO SC -1 RELIABLE / 4451ZBI 875 1 SC -3 SIMILAR TO 5C -1 RELIABLE / 44510I 85:5 1 NOTES: TO SUIT. 1. PROVIDE SCREEN WIDTHS MOTOR EFFICIENCY SCHEDULE (FOR WSEC) Exceptions: 1.° Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14-1A or 14 -18) 3. Motors that are an integral part (i.e. riot easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion -proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L: listing for the equipment is with a less - efficient and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies, Minimum Nominal Full -Load Efficiency Open Motors p Closed Motors Synchronous speed (RPM) 3,600 1,800 1200 3,600 1,800 1200 HP Efficiency (7) Efficiency ( %) 1.0 77.0 855 825 77:0 85.5 825 1.5 84.0 86.5 86.5 84.0 86.5 875 2.0 855 86.5 875 855 865 885 3.0 85:5 895 88.5 865 895 895 5.0 86.5 895 895 885 895 895 7.5 885 91.0 902 895 91:7 91.0 10 89.5 91.7 91.7 902 91.7 91.0 15 902 93.0 91.7 91.0 92.4 911 20 91.0 93.0 92.4 91.0 93.0 91.7 25 91.7 93.6 93.0 91.7 93.6 93.0 30 91.7 94.1 93.6 91.7 93.6 93.0 40 92.4 ` 94.1 94.1 92:4 94.1 ; 94.1 50 93.0 94.5 94.1 93.0 94.5 94.1 60 93.6 95.0 94.5 93:6 95.0 94.5 75 93.6 95.0 94.5 93.6 95.4 95.4 100 93.6 95.4 ;_ 95.0 94.1 95.4 , 95.0 125 94.1; 95.4 95.0 95.0 95.4 95.0 150 94.1 95.8 95.4 95.0 95.8 95.8 200 95.0 95.8 95.4 95.4 962 95.8 250 95.0 95.8 95.4 95.8 962 95.8 300 95.4 95.8 95.4 95.8 962 95.8 350 95.4 95.8 95.4 95.8 96.2 95.8 400 95.8 95.8 95.8 95.8 96.2 95.8 450 95.8 96.2 962 95.8 962 95.8 500 95.8 962 962 95.8 962 95.8 RECEIVED CITY OF TUKWILA, OCT` 16 2012 PERMIT CENTER 1 Engineering Services Inc. HLNT 9560 Moran Road NE Bainbridge Is, WA 98110 Phone: 206.842.6947 Fara 206.842.6948 co co co 0) J 0 co z 5 HUNT ENG. JOB #: HUNT # DATE ISSUED: 2/19/2010 FOR CONSTRUCTION REVISIONS: \ 31212010 - FUTURE DUCT LAYOUT / x\ 6/712010 - FOR CONSTRUCTION /4\ 312412011 - CHILLER REVISIONS A\ 71212012 - CHILLERICRAC ADD A SHEET CONTENTS:' MECHANICAL SCHEDULES SHEET NUMBER: M-4 4 of 4 COPYRIGHT © 2012 by HUNT ENGINEERING SERVICES Inc.