Loading...
HomeMy WebLinkAboutPermit M12-176 - BOEING #9-59BOEING #9 -59 9725 EAST MARGINAL wys M12 -176 City *Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0003400018 Address: 9725 EAST MARGINAL WY S TIIKW Project Name: BOEING #9 -59 Permit Number: M12 -176 Issue Date: 11/26/2012 Permit Expires On: 05/25/2013 Owner: Name: BOEING COMPANY THE Address: PROPERTY TAX DEPT , PO BOX 3707 M/C 20 -00 98124 Contact Person: Name: ROSS GARVEY Address: PO BOX 249 , AUBURN WA 98071 Email: ROSSGARVEY @AUBURNMECHANICAL.COM Contractor: Name: AUBURN MECHANICAL INC Address: PO BOX 249 , AUBURN, WA 98071 Contractor License No: AUBURMI163BA Phone: 206 571 -0180 Phone: (253)838 -9780 Expiration Date: 09/12/2014 DESCRIPTION OF WORK: RELOCATE EXISTING CEILING DIFFUSERS, GRILLES, AND THERMOSTAT TO SUPPORT RECONFIGURATION OF MEDICAL LAB TO OPEN OFFICE SPACE. Value of Mechanical: $4,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $233.13 International Mechanical Code Edition: 2009 Date: t I I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: 1/ -'7' .—/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. or: IM(' -4/1 n M12 -17R Printert• 11 -7R -2(112 PERMIT CONDITIONS Permit No. M12 -176 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. rrnr: IM( -d /1 f1 M12 -17R Printed. 11 -2A -2/112 CITY OF TUKA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov • Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION 01-0 Site Address: Tenant Name: King Co Assessor's Tax No.: 5624201032 9725 E Marginal Way S, Tukwila, WA 98108 Boeing Development Center PROPERTY OWNER Name: Ross Garvey Name: Boeing Company City: Auburn State: WA Zip: 98071 Address: P.O. Box 3707, MS 96 -11 Email: rossgarvey @auburnmechanical.com City: Seattle State: WA Zip: 98124 CONTACT PERSON — person receiving all project communication Name: Ross Garvey Address: P.O. Box 249 City: Auburn State: WA Zip: 98071 Phone: (206) 571 -0180 Fax: (253) 833 -1384 Email: rossgarvey @auburnmechanical.com Suite Number: Floor: New Tenant: ❑ Yes g..No MECHANICAL CONTRACTOR INFORMATION Company Name: Auburn Mechanical Address: P.O. Box 249 City: Auburn State: WA Zip: 98071 Phone: (253) 838 -9780 Fax: (253) 833 -1384 Contr Reg No.: AUBURMI163A Exp Date: 09/12/2013 Tukwila Business License No.: BUS- 0100148 Valuation of project (contractor's bid price): $ 4,000 Describe the scope of work in detail: Building Permit #D -12 -351. Relocate existing ceiling diffusers, grilles and thermostat to support reconfiguration of medical lab to open office space. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: H:\Applications \Forms- Applications On Line1201 I ApplicationsWlechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended /wall /floor mounted heater Appliance vent Repair or addition to heat /refrig /cooling system Air handling unit <10,000 cfin Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm /industrial Unit Type Qty Fire damper Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1 ,750,000 btu IT APPLICATION NOT Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGEN Signature: Date: 11/13/2012 Print Name: Ross Garvey Day Telephone: (206) 571 -0180 Mailing Address: P.O. Box 249 H: Applications Forms-Applications On Line 2011 Applications. Mechanical Permit Application Revised 0-9-11 .docx Revised: August 2011 bh Auburn WA 98071 City State Zip Page 2 of 2 { City of Tt$vilar Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site hro: /dvww cr tukwila wa.us SET RECEIPT Copy Reprinted on 11 -13 -2012 at 15:31:02 11/13/2012 RECEIPT NO: R12 -03099 Initials: JEM User ID: 1165 Payee: AUBURN MECHANICAL Payment Date: 11/13/2012 Total Payment: 309.26 SET ID: S000001823 SET NAME: Temporary Set SET TRANSACTIONS: Set Member Amount Ir`M12-176 233.13 PG12 -196 76.13 TOTAL: 76.13 TRANSACTION LIST: Type Method Description Amount Payment Check 0011607 309.26 TOTAL: 309.26 ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES PLUMBING - NONRES 000.322.102.00.0 000.345.830 000.322.103.00.0 186.50 61.86 60.90 TOTAL: 309 .2 6 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 MI? -17C, Project: C c Type of Inspection: Address: cin;.S -,ks; >1AA- ICJAAL_ Date Called: Special Instructions: Date Wanted:. 11 t2-7 1 ("Z , a'm. p.m. Requester: Phone No: a..o(e, ---730-7579 Approved per applicable codes. Corrections required prior to approval. COMMENTS: jL � Lt vT 2\S L t n K- M e,r ik pr&rr &kp\.e)P Inspector Date:' n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. THE UIJEIN& COMPANY SUPPORT SERVICES GROUP REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 9 ) BUILDING - ENTERPRISE SECURITY REMODEL BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 VICINIT xopro--KE pC�P -MIT R 99 9 -59 BUILDING PROJECT SfTE FROM DOWNTOWN SEATTLE \ vao. gioCt •� ss. \`.•\DxBOw \'I 0 99 900 r^_ EXIT 158 V��IESS RD A i EAST MARGINAL NAT CORPORATE PARK FROM SEATTLE- 1ACOMA AIRPORT 599 TUKWILA EXIT DEVELOPMENTAL CENTER FROM KENT & AUBURN \ i EXIT 900 NO RCM F CODE SUMMARY TYPE OF APPLICATION: NEW ALTERATION❑ ADDITION❑ TENANT IMPROVEMENT rg PROJECT DESCRIPTION: RECONFIGURATION OF EXISTING MEDICAL LAB TO OFFICE SPACE FOR ENTERPRISE SECURITY. WORK INCLUDES REMOVAL AND CONSTRUCTION OF NON- BEARING INTERIOR PARTITIONS, RELOCATION OF LIGHTING AND HVAC DIFFUSERS AND GRILLES, INFILL OF EXISTING EXTERIOR GLAZING' WITH INSULATED PANELS. CODES: 2009 INTERNATIONAL BUILDING CODE & WAC 51 -50 2009 INTERNATIONAL MECHANICAL CODE & WAC 51 -52 2009 INTERNATIONAL FIRE CODE & WAC 51 -54 CURRENT WASHINGTON STATE ENERGY CODE WAC 51 -11 CURRENT CITY OF TUKWILA ZONING ORDINANCES CONTRACTOR & STATE NUMBER. THE BOEING CO. BOEINC *294ML(OV2009) BOEING PROJECT ENCINE1R. THOMAS HANSON AIA 0 206 - 947 -4880 BOEING CONTACT: JOHN MURDOCH 8H0Nr. 253- 773 -0444 FAX NUMBER: 253- 773 -0119 E -IJ AIL: ohn.s.murdocheboeinq.com ZONING: OCCUPANCY GROUP. GROUP 131 BUSINESS CONSTRUCTION TYPE: TYPE II -B ALLOWABLE AREA INCRIASP 60' SET -BACK (NO CHANGES) OCCUPANT LOAD: (ALLOWABLE) NO CHANGE FLOOR AREA: (ACTUAL) NO CHANGE (TABLE 10 -A) OFFICES SF occ 10 BLDG GROSS 1,298 SF CO FT STORAGE OCC TUNNEL SO 1T LABORATORY OCC FIRST FLOOR 1.298 SF SO FT CANOPY NEC 1sT FIR MEZZ SO F1 OTHER OCC 2ND FLOOR 50 FT 200 FLOOR MEP �0 F1 PROJECT AREA. 950 SF 50 r5 BUILDING HEIGHT: (ACTUAL) 13'-6" FT STORIES: 1 MEZZANINE ? ❑ (`ES) ® (NO) FIRE PROTECTION: SPRINKLERED THROUGHOUT PER NEPA i3 ? SO FT ❑ (YES) ® (NO) SEPARATION EXTERIOR WALL (NON- BEARING) HOUR RATING EXTTERIOR WALL (BEARING) HOUR RATING INTERIOR WALL (NON-BEARING) POUR RATING INTERIOR WALL (BEARING) HOUR RATING DEMOUNTABLE PARTITIONS HOUR RATING STRUCTURAL FRAME HOUR RATING FLOOR /CEILINGS HOUR RATING ROOF CONSTRUCTION HOUR RATING SEISMIC DESIGN: ZONE ,D DESIGN LOADS: (CHAPTER 16) ROOF: LIVE (SNOW) (PSF) FLOOR: OFFICE (050) 1IECH /STOR (050) STAIRS (PSF) CONCENTRATED' WIND: EXPOSURE 80 MPH. EXPOSURE C CODES AND PERMITS REVIEWED FOR CODE COMPLIANCE I APPROVED NOV 21 2012 - J N / Ity of wlia BUILDIN VISION DRAWING INDEX ARCHITECTURAL - CIVIL DRAWING NUMBER REV DRAWING TITLE 09- 059 -G1 09- 059 -1A1OR 09-059- 1A280R 09- 059 -1A10 09- 059 -1A280 09- 059 -A500 TITLE SHEET D D B B REMOVAL FLOOR PLAN REFLECTED CEILING REMOVAL PLAN FLOOR PLAN REFLECTED CEILING PLAN MISCELLANEOUS DETAILS PROJECT TITLE: 9 -053 INSTALL TWO ROOMS SUSPENDED CLGS 20B NUMBER: P2125341 QUANTITY SUBMITTED: ❑ 5 SETS: GENERAL PERMIT (SHELL & CORE) OR STRUCTURAL TENANT IMPROVEMENT ® 4 SETS: TENANT IMPROVEMENT (NON- STRUCTURAL) ❑ 3 SETS: FIRE PROTECTION /SPRINKLERS ❑ 2 SETS: TENANT IMPROVEMENT (REVISION) SUBMITTED FOR PERMIT & REVIEW: ▪ BUILDING ❑ GRADING ❑ ELECTRICAL ❑ PLUMBING ❑ LANDSCAPE ❑ FIRE PROTECTION* ❑ MECHANICAL ❑ DEMOLITION ❑ CANTILEVER RACKS ❑ STRUCTURAL ❑ - *TO BE RENEWED UNDER SEPARATE PERMIT WASHINGTON STATE NON- RESIDENTIAL ENERGY CODE- APPROACHES COMPLIANCE OPTON p PRESCRIPTIVE ❑ LPA ❑ ANALYSIS 'Z N/A SPECIAL INSPECTIONS REQUIRED: ❑ WELD ❑ REBAR ❑ STRUCTURAL BOLTING ❑ OTHER CALCULATIONS TYPE: N/A ❑- ❑ CONCRETE ❑ ANCHOR BOLTS ❑ STRUCTURAL OBSERVATION ATTACHED (YES) -(N0) DRAWING INDEX MECHANICAL DRAWING NUMBER REV DRAWING TITLE 09- 059 -1M1OR HVAC PLAN - REMOVAL 09- 059- 1M110R PLUMBING PLAN - REMOVAL 09- 059 -M5 F r vi Lc, .oil 0� pro STRUCTURAL DRAWING NUMBER REV DRAWING TITLE S REQUIRED FOR: • Electrical Plumbing Gas Piping Y OF TUKVT! B N NOV 1 3 101 Z PERMIT CENTER 5Y REVISION 8' APPROVED DATE 5Y REVISOR En APPROVED ENTERPRISE SECURITY REMODEL 416919 -20 C /ROLLUDA 10 31.12 g)LATOEIAW • ACCEPTAB LITY 1145 DESIGN AND /OR SPECIFICATION 6 APPROVED APPROVED 08 DEPT. DATE GRAwN &REYNOLDS EHLLK1.0 LNGINLLH DHEDKED APPROVED 00000050 GATE 12. SUET" 20.90 B 09- 059 -1M 09- 059 -1M 09- 059 -M500 P.LB DIAGRAM - REMOVAL l7BIN 9 PLAN PIPING DESAtLS ';!f:1.1s1f, Vf: 1! f.1 1: 11411�i (,T:lhi,1ti-i:1.4111-1111; :1 ►lii: Na ldc;it7f i rr alif'T�if�:T?i1LA:(.TL�Tu\IT:th • e.: = =Ld.. . /\R ^T �Vv +i T::. .1 `1) - ►:1- ;;::1 -0: F: :1P 4 1 • :-.:f • 1(:1=INTirIGiVII City Of Niskwlia DRAWWI IWINGVDIVISI NNG TITLE 09- 059 -1E6R 09- 059 -1E1OR B 09- 059 -1E6OR C 09- 059 -1E6 09- 059 -1E10 09- 059 -1E60 09- 059 -E500 B C TELEPHONE & FIRE ALARM SYSTEM - REMOVAL LIGHTING PLAN - REMOVAL 120V/208V POWER PLAN - REMOVAL TELEPHONE & FIRE ALARM SYSTEM LIGHTING PLAN 120V/208V POWER PLAN ELECTRICAL SCHEDULES & ONE -LINE DIAGRAM 90% SUBMITTAL CITY OF TUKWILA BLANKET PERMIT NO. 12 -001 -BPA 1 PROJECT TITLE: 9 -59 ENTERPRISE SECURITY REMODEL CURRENT REVISION 5818008 DATE COVER SHEET #16919 -20 10.31.12 TIRE ENTERPRISE SECURITY REMODEL BUILDING 9 -59 ARCHITECTURAL MASTER COL. D.C. SHEET G1 ASP 16919 -20 000 NO. 09- 059 -G1 FLOOR PLAN SCALE: 1/4 = �WF SYM RENSION BT APPROVE0 DATE 5YM REVISION ID APPROVED DATE A RELOCATE MEDICAL TO 9 -59 BLDG 110773 -00 1WH 01.23.02 B • RAISE CANOPY C REBUILD BACK ENTRY D ENTERPRISE SECURITY REMODEL 110773 -08 TWIT 110773 -06 T. HAN50N 16919 -20 EC /ROLLUOA 02.26.02 05.10.02 10.31.12 gi_IFISFEZAV e REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2012 City of Tukwila BUILDING DIVISIO REMOVAL ACCEPTABILITY RACGI M E DITTMAR TH15 DESIGN AND /OR CHECKED SPECIFICATION 9 APPROVED 1WH 01.23.02 1.NI:INLEH TITLE APPROVED 90 DATE TWH 01.16.02 'CHECKED APPROVED LA% SUBTNEE 4 -15 -96 APPROVED LEGEND I � NEW FLOOR TO CEILING WALL. NEW 15.009 TO CEILING WALL W /ROCK WOOL SOUND INSULATION. EXISTING FLOOR TO CEILING WALL TO REMAIN. GENERAL NOTES REMOVAL NOTES REMOVE EXISTING WALL FROM FLOOR TO CEILING COMPLETE. PATCH AND REPAIR EXISTING FINISHES AT AREAS TO REMAIN AS REQUIRED BY REMODEL. REMOVE EXISTING WOOD DOOR, HM FRAME AND HARDWARE. RETAIN (1) 3' -0" X 7' -0" DOOR /FRAME /HARDWARE SET FOR RE —USE IN THIS PROJECT. CONTACT PROJECT MANAGER FOR DISPOSITION OF REMAINING DOORS. REMOVE EXISTING CARPET AND BASE IN AREA HATCHED. APPROX. 805 S.F. REMOVE EXISTING CASEWORK AND PLUMBING FIXTURES. CONTACT PROJECT MANAGER FOR DISPOSITION OF CASEWORK. CAP UTILITIES AS REQUIRED. SEE MECHANICAL. REMOVE D3STINC VINYL FLOORING AND BASE IN AREA HATCHED. '. APPROX. 215. S.F. SEAL DOOR IN CLOSED POSITION. REMOVE HARDWARE AND REPLACE WITH BLANKS AT BOTH SIDES. 90% SUBMITTAL RECEiVE0 CITY OF TUK.1M4_ A. NOV 13 2012 PERMIT CENTER 4' 2' 0 2' 4' 8' IMM SCALE: 1/4"=1' —0" REMOVAL FLOOR PLAN sY"BD` 16919 -20 D 0AT1 10.31.12 ENTERPRISE SECURITY REMODEL BUILDING 9 -59.1 ARCHITECTURAL MASTER COL. ALL SHEET 1A10R .LOB NO 16919 -20 COMP NO. DEV. CENTER, WA 0w0 N0' 09- 059 -1AIOR D1ST.CEILING HEIGHTS 0 (VERIFY) REFLECTED CEILING PLAN SCALE: 1/4" = REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2012 City of Tukwila BUILDING DIVISION REMOVAL 5YN RENS.% By APPROVED sr REVISION Br APPROVED A RELOCATED MEDICAL TO D.C. 110773 -00 TWH 01.23.02 B ENTERPRISE SECURITY REMODEL 16919 -20 :C /ROLLUD 10.31.12 proweAfc e ACCEPTABILITY TH5 DESIGN AND /OR SPEC81CA00N b APPROhD APPROVED BY DEPT. DATE URAWN M. DITTMAR WLCKEU TWH OCANE1N THOMAS HANSON DATE 12 -06 -01 01.13.01 12.18.01 SUBTITLE LEGEND 0 2 LAMP, 2x4 FLOURESCENT FIXTURE 2 LAMP, 1x4, FLUOR. FIXTURE. SURFACE MOUNT XX 23 WATT FLUORESCENT TUBE LIGHT O FLUORESCENT PENDANT UGHT ® EXIT LIGHT �i RELOCATED SURGERY LIGHT, MOUNT TO STRUCTURE ABOVE, MODIFY RELOCATED SUPPORT l 1 C' O\ OVER LAV WALL FLUOR LIGHT 2X2 DIFFUSER RETURN AIR 2x4 RETURN AIR CEILING MOUNTED CURTAIN TRACK GENERAL NOTES NOTE: EXISTING CEILING GRID TO REMAIN AS IS, NO WORK. 1 , INSTALL NEW ACCOUSTICAL CEILING TILES IN EXISTING CEIUNG GRID THROUGHOUT (TYP), I[> INSTALL SOUND INSUL. BATTS OVER CEILING TILES. DO NOT COVER LIGHT FIXTURES AS OVERHEATING MAY OCCUR. EXTEND SOUND INSULATION BEYOND ROOM WALLS 4 FEET. ROOMS TO RECEIVE CEILING SOUND INSULATION ARE: EXAM ROOMS 1 & 2 AND OFRCES 1. 2 & 3. REFERENCE DRAWINGS 59 —A3 AUSTIN DRAWING DATED 12/62 REMOVAL NOTES REMOVE EXISTING OVERHEAD LIGHT MOUNT. PATCH AND REPLACE CEILING TILE AS REQUIRED TO MATCH EXISTING ADJACENT. RELOCATE /REPLACE EXISTING LIGHT FIXTURES PER ELECTRICAL SHEETS THIS SET. RELOCATE /REPLACE EXISTING DIFFUSERS PER MECHANICAL SHEETS THIS SET. ® CLEAN GRID AND TILES. REMOVE DAMAGED TILES AS REQUIRED BY REMOVAL WORK. 90% SUBMITTAL REFLECTED CEILING REMOVAL PLAN RECEI EO CITY OF TUKVOL.A NOV 1 3 2012 PERMIT CENTER 4' 2' 0 2' 4' 8' SCALE: 1/4-.1' —0" CURRENT MMSgN 16919 -20 STNBOE B DATE 10.31.12 CHLCKED APPROVED ENTERPRISE `.:CURITY REMODEL ARCHITECTURAL MASTER BUILDING 9 -59.1 COL. ALL DEV. CENTER, WA S~EET 1A280R .DO ND. 16919 -20 COMP N0. DOS No. 09- 059- 1A280R LEGEND NEW FLOOR TO CEILING WALL. NEW F.000 TO CEIUNO WALL W /ROCK WOOL SOUND INSULATION. EXISTING FLOOR TO CEILING WALL TO REMAJN. 15' —O" GENERAL NOTES 1. All DIMENSIONS ARE FROM FACE OF FINISH TO FACE OF FINISH UNLESS OTHERWISE NOTED. 2. All NEW WALLS ARE 18 GA METAL STUDS 0 16' 0.C. W/5/8" GWB TAPED, SANDED AND PAINTED 8001 COLOR. 3. PROVIDE WALL BACKING FOR ALL WALL HUNG CABINETS AND FIXTURES. SEE SHEET A370. 4. PRIOR TO FRAMING START, VERIFY WALL LAY —OUT W /ARCHITECT. •OCCUPANT LOAD 18 268 S.F) 12'. -8" z • 21' =6" OCCUPANT LOAD 7 605 S.F. REVIEWED FOR CODE COMPLIANCE APPROVED 16> 7 8 INSTALL NEW 8450 THROUGHOUT WITH THE FOLLOWING EXCEPTIONS: RESTROOM # 2 & THE EXISTING MECHANICAL ROOM. PAINT ALL WALLS VANILLA PUMICE COLOR WITH THE FOLLOWING EXCEPTIONS: THE EXISTING MECHANICAL ROOM. INSTALL NEW CARPET TILES THROUGHOUT WITH THE 10110WING EXCEPTIONS: EXAM ROOM 11, EXAM ROOM /2 & EMERGENCY ROOM. PAINT DOOR FRAMES TO MATCH WALLS. INSTALL SHEET VINYL FLOORING IN THE FOLLOWING ROOMS: EXAM 11, EXAM 12, RESTROOM 11, EMERGENCY AND CLOSET. FOR INTERIOR ELEVS & EQUIP PLACEMENT, SEE SHEET 0.370 PREP & FILL HOLES OF SUBFLOOR PRIOR TO CARPET PLACEMENT SSG ROOF PAINT. TO PROVIDE 1 "e CONDUIT THRU ROOF PENETRATION. CCU TO COORDINATE. CONSTRUCTION NOTES NOV 21 2012 OCCUP/ 13 1V-6" City of Tukwila BUILDING DIVISION CONSTRUCT NEW WALL FROM FLOOR TO CEILING: 3 5/8" 18 GA. STEEL STUDS AT 16" 0.C. W/ 5/8" GWB EACH SIDE AND ROCKWOOL ACOUSTIC INSULATION. PREP, SAND AND PAINT. ALL WALLS, BOTH NEW AND EXISTING ARE TO BE PREPPED, AND PAINTED. SEE FINISH SCHEDULE FOR FINISH. CONSTRUCT NEW WALL FROM FLOOR TO CEILING: 3 5/8" 18 GA. STEEL STUDS AT 16" 0.C. W/ 5/8" GWB EACH SIDE. PREP, SAND AND PAINT. ALL WALLS, BOTH NEW AND EXISTING ARE TO BE PREPPED, AND PAINTED. SEE FINISH SCHEDULE FOR FINISH. PROVIDE NEW HM DOOR FRAME. INSTALL EXISTING 3' -0" X 7-0" WOOD DOOR AND HARDWARE. REFINISH DOOR AS REQUIRED. PAINT HM FRAME PER FINISH SCHEDULE. PROVIDE NEW 24" X 24" CARPET TILE AT AREA HATCHED. 1/4 TURN EVERY OTHER TILE. APPROX. 1,005 S.F. PROVIDE AND INSTALL NEW 4" RUBBER BASE AT ALL AREAS RECEIVING NEW CARPET. SEE FINISH SCHEDULE FOR CARPET AND BASE. OCCUPANCY — B OCCP. LOAD= 27 PROVIDE WINDOW FILM AT INTERIOR SIDE OF GLAZING. PRODUCT: 3M FASARA GLASS FINISHES — 'MILKY MILKY' PROVIDE AND INSTALL CYPHER LOCK AT EXISTING DOOR. PROVIDE INFILL AT EXISTING WINDOW /DOOR LOCATION: CENTRIA FORMAWALL 2" INSULATED METAL PANEL SEE DETAIL H /A500. CLEAN AND PAINT EXISTING CEILING GRID AND ACOUSTIC 1111 PANELS. REPLACE ANY DAMAGED CEILING TILES AS REQUIRED BY EXISTING CONDITIONS OR NEW WORK. FLOOR PLAN SCALE: 1/4" = 1' -0" RECO:I�r L CITY OF TU NOV 1 3 2012 PERMIT CENTER SCALE: 1/4 " =1' -0" 90% SUBMITTAL RELOCATE MEDICAL TO 9 -59 BLDG RAISE CANOPY 110773 -00 01.23.02 REBUILD BACK ENTRY 110773 -08 110773 -06 ENTERPRISE SECURITY REMODEL T. HANSON 02.26.02 05.10.02 16919 -20 :C /ROLLUDA 10.31.12 eLArz /6® ACCEPTABILITY µ4GCIE DITTMPR 4-15 -96 MS DESIGN AND /0R SPEOFlGTOI 6 APPRO*ED 11YH N41 4 APPROVED BY DEPT. DATE TWIT NECRED PROVtD 01.23.02 01.16.02 FLOOR PLAN CURRENT RENS. . 16919 -20 10.31.12 ENTERPRISE SECURITY REMODEL BUILDING 9 -59.1 ARCHITECTURAL MASTER COL. ALL DEV. CENTER, WA JOB N0. COMP NO. 16919 -20 ` 09- 059 -1A10 LEGEND EXIST.COLING HEIGHTS 0 (VERIFY) REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 1 2012 2 LAMP, 2x4 FLOURESCENT FIXTURE 2 LAMP, 1x4, FLUOR. FIXTURE, SURFACE MOUNT iT 23 WATT FLUORESCENT TUBE LIGHT O FLUORESCENT PENDANT LIGHT O EXIT LIGHT • RELOCATED SURGERY LIGHT, MOUNT TO STRUCTURE ABOVE, MODIFY RELOCATED SUPPORT I OVER LAV WALL FLUOR LIGHT Q 2X2 DIFFUSER RETURN AIR 2x4 RETURN AIR CEILING MOUNTED CURTAIN TRACK GENERAL NOTES NOTE: EXISTING CEILING GRID TO REMAIN AS IS, NO WORK. I 1 > INSTALL NEW ACCOUSTICAL CEILING TILES IN EXISTING CEIUNG GRID THROUGHOUT (TYP). 2 > INSTALL SOUND INSUL BATT5 OVER CEILING TILES. DO NOT COVER LIGHT FIXTURES AS OVERHEATING MAY OCCUR. EXTEND SOUND INSULATION BEYOND ROOM WALLS 4 FEET. ROOMS TO RECEIVE CEILING SOUND INSULATION ARE: EXAM ROOMS 1 & 2 AND OFFICES 1, 2 & 3. REFERENCE DRAWINGS 59 -A3 AUSTIN DRAWING DATED 12/62 CONSTRUCTION NOTES PAINT EXISTING GWB CEILING PER FINISH SCHEDULE. t- RELOCATE /REPLACE EXISTING LIGHT FIXTURES PER ELECTRICAL SHEETS THIS SET. RELOCATE /REPLACE EXISTING DIFFUSERS PER MECHANICAL SHEETS THIS SET. • CLEAN GRID AND TILES. REMOVE DAMAGED TILES AS REQUIRED BY REMOVAL WORK. PATCH AND REPAIR GWB CEILING AS REQUIRED FOR INSTALLATION OF NEW FIXTURE. MATCH EXISTING ADJACENT FINISHES. REFLECTED CEILING PLAN SCALE: 1/4" = 1. -0" RECEIvr::,) CITY OF TUK, "M ;_i' NOV 1 3 2012 PERMIT CENTER SCALE: 1 /4 " =1. -0" 90% SUBMITTAL 110773 -00 B ENTERPRISE SECURITY REMODEL 16919 -20 01.23.02 C /ROLLUDA 10.31.12 unN M§DMAR TWH LNWNLLN THOMAS HANSON tHECNED APPHOVLU 12 -06 -01 01.23.02 12 18.01 SUBTITLE REFLECTED CEILING PLAN CURRENT RENSgN 16919 -20 'Ti ENTERPRISE SECURITY REMODEL BUILDING 9 -59.1 ANTE 10.31.12 1A280 16919 -20 ARCHITECTURAL MASTER COL. ALL DEV. CENTER, WA COUP NO. 09- 059 -1A280 26 GA GALV FLASHG TYP TS 8x4x 1/4" WELD TO POST TYP TS 4x4x1/4" POST TYP FLASHING 18 GA RIB ROOFING 18 GA END CLOSURE WATERTIGHT SEAL 0 JOINTS 5/16 ►/ <YP TS 4x4x1/4 POSTS BRG PLATE 1/2 "x9 "x0' -9" TS 4x4x1/4 PURLIN WELD TO STL BM 20 GA GALV STL GUTTER 20 DS TS 8x4x1/4 BM !WELDED TO !STEEL POST IL 1 1 /4x1 1/4x1/8 ITACK WELD CANOPY SLOPE NEW EL 11' -0 3/4" TS 4x4 POST EXTEND i' -6" TYP. D.S. ASPHALT PAVING DISPENSARY FLOOR EL 1' -7" EL 0' 0" CANOPY COLOR SCHEDULE FASCIA OXFORD BROWN POSTS BASE PLATE : BEIGE ( A .) SECTION (T) SCALE: 1 1/2 " =1' -O" A1601 00 A1601AA500 SECTION SCALE 1 1/2 " =1' -0" 1A10L 00 A160LA500 MECHANICAL HOOD (METAL) OR CAP INTERIOR 3- 1/4 "X8 -1/8" GLU -LAM TAPE ACROSS JOINT 5/8° GWB TAPED, SANDED & PAINTED CURB 2 "x6" W /4x4 CANT 1 BLOCKING FIBER GLASS INSUL, IN -FILL 3/8 "0.1 -1/2" LAG BOLT ANCHOR W /WASHER NOTCH CEIL'G TILE A; REOUIRED. 1 -1/2 "0 PIPE RAILING PAINTED BLACK PEPPER �\ 4" HIGH TOE KICK - 2x6 TREATED DECKING - 2x6 JOISTS 0 16 "O.C. - 2X6 METAL HANGERS 3/8 "x5" LAG BOLTS W /WASHERS 0 16" O.C. 4 "x12" TREATED STRINGERS 4 "x12" TREATED TREADS zz,-- EXTERIOR 1/2" AC EXT. PL "!WOOD CUT TO IN -FILL OPENING SIZE FRP BONDED TO PLYWOOD (BY BOEING) EXIST. STOP TO REMAIN SOUND INSULATION WHERE INDICATED ROOF EXHAUST CURB DETAIL SCALE: 1 "= 1' -0" BRACES 3/4 "0 RIGID METAL CONDUITIAS SHOWN OR 25 GA. STL. STUDS - ALTERNATE DIRECTION EVERYOTHER BRACE ,FLATTEN ENDS OF 3/4 "0 STRUTS -AND FASTEN TO STL. TOP RUNNER OF PARTITION W/(2)112xi/2" LONG PAN HEAD SCREWS. 12" CONCRETE PIER BLOCKS (1 1 WINDOW INFILL DETAIL ("S A160L,500 SCALE: 1 -1/2" = 1' -0" A50000 Simpson Strong -Tie TA10 CEILINGS AND DEMOUNTABLE PAR;'N PARTITION BRACING AT ACOUS. SUSP. SCALE: NONE ELEVATION VIEW (T SCALE NONE 1A10100 1A101 00 EXISTING WINDOW FRAME 2' -6" PC TS 4- 1/2x4- 1/2x1/4 W/ 1' -6" PC TS 4x4x1/4 INSIDE SOLID BLOCK DOCK BUMPER MOLDED STRIPED DOCK BUMPER SAFETY CHAIN 1" NYLON MINI - RATCHET EXISTING GLAZING AND STOP. LEAVE GLAZING IN PLACE. EXISTING CEILING 2" PRE - FINISHED METAL FACED INSULATED PANEL 1/4 ROUND TRIM ALL FOUR SIDES OF METAL PANEL EXISTING WALL CONSTRUCTION NOTE: CUT TS 4x4x1/4 POST. RAISE CANOPY 1 -1/16" HIGHER. PLACE TS 4- 1/2x4 -1/2 SLEEVE. CUT & SPLICE DOWNSPOUT & ELECTRICAL CONDUIT ATTACHED TO CANOPY AS REOUIRED. REClvs E' J CITY OF TUKW , P. PERMIT 3 2012 p PERMIT y CENTER DETAIL SCALE: 1 -1/2" = 1' -0" ELEVATION VIEW SCALE: NONE 1A10 A500 WINDOW SECTION SCALE: NONE 1A10 A500 — REDRAWN FROM 109- 059 - 1002 -01 A RELOCATE MEDICAL TO 9 -59 BLDG 8 RAISE CANOPY C RELOCATE MEDICAL TO 9 -59 D RELOCATE MEDICAL TO 9 -50 110773 -00 110773 -00 110773 -00 110773 -06 T. HMISON 12.5.01 E ENTERPRISE SECURITY REMODEL 12.20.01 01.09.02 01.23.02 05.10.02 16919 -20 C /ROLLUDA 10.31.12 gifiri7E/AW ACCEPTABILITY 11.I5 OESx:N AND /0R SPECIFICATION 0 APPROVED APPROVED RV ATE 05.10.02 05.10.02 RELEASED FOR CONSTRUCTION FAOUTY DE9GN or rll 0 9.060902.. CURRD0 REVISION DETAILS AND SECTIONS ENTERPRISE SECURITY REMODEL 16919 -20 10.31.12 BUILDING 09 -59 ARCHITECTURAL MASTER COL.N /A DEV. CENTER, WA JOB 16919 -20 °W` W. 09- 59 -A500 0 40 EXHAUST VENTILATOR (PART OF LIGHT) CONDENSING UNIT HVAC PLAN SCALE: 1/4" = 1' -0" -300 C11A AIR HANDLING UNIT TRANS MODEL No 19N060P -15A 2000 CFM FITTED WITH SMOKE DETECTOR (SEE ELECTRICAL) REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2012 City of Tukwila BUILDING DIVISION O REGLIV CITY OF TUK IM A'. NOV 1 3 2012 PERMIT CENTER i LEGEND O 2 LAMP, 2x4 FLUURESCENT FIXTURE ET= 2 LAMP, 1x4, FLUOR. FIXTURE, SURFACE MOUNT L:1 23 WATT FLUORESCENT TUBE LIGHT 0 EXIT LIGHT 2X2 DIFFUSER 0 RETURN AIR 2x4 RETURN AIR DUCT CLEANING ACCESS GENERAL NOTES 1. CONTRACTOR SHALL INVESTIGATE AND VERIFY LOCATIONS OF STRUCTURAL, MECHANICAL, AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS PRIOR TO JOB START. 2. ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONTRACT DOCUMENTS SHALL BE CALLED TO THE ATTENTION OF THE OWNER. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WNH ALL APPLICABLE CODES AND STANDARDS. 4. THE CONTRACTOR SHALL COORDINATE SYSTEM SHUTDOWNS WITH THE BOEING CONSTRUCTION MANAGER. 5. ALL EXISTING DUCTWORK TO BE REMOVED SHALL BE DECONTAMINATED PRIOR TO DISPOSAL PER BOEING ENVIRONMENTAL STANDARDS. REFERENCE DRAWINGS REMOVAL NOTES REMOVE EXISTING DIFFUSER AND ASSOCIATED DUCTWORK. PROVIDE DUCT CAP DOWNSTREAM OF EXISTING VOLUME DAMPER. REMOVE EXISTING RETURN GRILLE, DUCTWORK AND ASSOCIATED APPURTENANCES. RELOCATE EXISTING 2' -0" X 1' -0" RETURN GRILLE, DUCTWORK AND ASSOCATED APPURTENANCES. FOR NEW LOCATION OF RETURN GRILLE SEE SHEET 1M10. RELOCATE EXISTING DIFFUSER AND MODIFY ASSOCIATED DUCTWORK TO ACCOMMODATE NEW CEILING. FOR NEW LOCATION OF DIFFUSER SEE SHEET 1M10. RELOCATE EXISTING 4'X2' RETURN GRILLE AND ASSOCIATED APPURTENANCES TO ACCOMMODATE NEW CEILING. FOR NEW LOCATION OF RETURN GRILLE SEE SHEET 1M10. RELOCATE EXISTING THERMOSTAT. FOR NEW LOCATION OF THERMOSTAT SEE SHEET 1M10. REMOVAL 90% SUBMITTAL 4' 2' 0 2' 4' 8' SCALE: 1/4"=1* —0' ar APPROVED LIVE SAE REV60 Br *PROEM DATE A RELOCATE MEDICAL TO 9 -59 BLDG. 110773 -00 D. VILLA 01.23.02 INSTALL 0111510E AIR DUCT 1001552591 RYAS 02.14.05 C ENTERPRISE SECURITY RELOCATION 16919 -20 GS /SAZAN 10.31.12 ACCEPTABILITY 7M5 0E9IGN AN0 /08 SPEGIFlEAPON 5 APPROY00 ORAWN MAGGIE DITTMAR 01AV' +• .ATE 4 -15 -96 12 -21 -01 HVAC PLAN CLMRENT REVISION 16919 -20 STUBOL DA 10.31.12 APPROVED BY DEPT NUNLLN DATE 014V 01.23.02 CHECKED DYED TOLE ENTERPRISE SECURITY RELOCATION BUILDING 9 -59.1 MECHANICAL MASTER COL. ALL DEV. CENTER, WA �D1M10R 16919 -20 COUP NO DWG NO. 09- 059 -1M10 • EXISTING 10" SANITARY SEWER EXISTING 18" STORM SEWER n6 , 1 1/2" GATE VALVE IN VALVE BOX EXIST. 8" C.W. MAIN /\ (EXAM 11 WAITING! RESTROOM °1 3" D.S. Ion 'OFFICE 3i-, 1/2" HW !GEN x MECH 1 ELECT JANITORIAL ROOM 3' SAN. HOT WATER HEATER (CLOSET( 3" FLOOR DRAIN PLUMBING PLAN SCALE 1/4" = 1'- VIA REVISION BY APPROVED DATE SYM BY APPROVED DATE A RELOCATE MEDICAL TO 9 -59 BLDG. 110773 -00 D. VILLA 01.23.02 ENTERPRISE SECURITY RELOCATION 16919 -20 GS /SAZAN 10.31.12 BO//Yia® ACCEPTABILITY THIS DESIGN MID /0R SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE (REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2012 City of Tukwila BUILDING DIVISION ORAwN EDUARDO DUARTE cHECKLE, 0. O L .VILA D. CHtCR OkEO 0 LEGEND GENERAL NOTES 1. CONTRACTOR SHALL INVESTIGATE AND VERIFY LOCATIONS OF STRUCTURAL, MECHANICAL, AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS PRIOR TO J08 START. 2. ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONTRACT DOCUMENTS SHALL BE CALLED TO THE ATTENTION OF THE OWNER. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS. 4. THE CONTRACTOR SHALL COORDINATE SYSTEM SHUTDOWNS WITH THE BOEING CONSTRUCTION MANAGER. 5. ALL EXISTING PIPING TO BE REMOVED SHALL BE DECONTAMINATED PRIOR TO DISPOSAL PER BOEING ENVIRONMENTAL STANDARDS. REFERENCE DRAWINGS REMOVAL NOTES 1I] REMOVE EXIST. PLUMBING FIXTURE (SINK) AND ASSOCIATED APPURTENANCES. REMOVE H &CW TO ABOVE FINISHED CEILING, VENT TO ROOF & WASTE TO BELOW FINISHED FLOOR. CAP WASTE PIPE BELOW FLOOR. PATCH WALL, ROOF & FLOOR TO MATCH WITH EXISTING. SEE ARCH. DRAWINGS FOR WALL, ROOF & FLOOR PATCH & FINISH. EXISTING WASTE LINE TO REMAIN ABANDON IN PLACE. EXISTING WASTE LINE TO REMAIN. REMOVAL ATE SUBiOLE 1 -06 -02 REGLiv L :) CITY OF NUV 1 3 2012 PERMIT CENTER 90% SUBMITTAL 4' 2' 0 2' 4' 8' SCALE: 1/4 " =1' -0" PLUMBING PLAN CURRENT REVISION SYMBOL 16919 -201 B DATE 10.31.12 01.23.02 1111L ENTERPRISE SECURITY RELOCATION BUILDING 9 -59.1 MECHANICAL MASTER COL. ALL SHEET 1 M 110 R JOB N0. DEV. CENTER, WA 16919 -20 COMP N0. 09- 059 -1M110 is`. 0. I \ \f LEGEND CW COLD WATER HW HOT WATER SAN SANITARY VTR VENT THROUGH ROOF LAV LAVATORY SINK WC WATER CLOSET (TOILET) EXISTING NEW EXISTING -{j BALL VALVE GENERAL NOTES 1. SPACE BELOW THE FLOOR IS VERY LIMITED. ALL UTILITY RUN SHALL BE PROVIDED TO ACCOMPLISHED THE INTENDED DESIGN. 2. PIPE HAS TO BE OFFSETTED TO ACCOMODATE THE ADA REOUIREMENT FOR WALL CLEARANCE, AND DOING SO WILL MAKE THE OTHER WATER CLOSET BE MOVED T00 SINCE THEY ARE BACK TO BACK CARRIER. HEIGHT ADJUSTMENT NEEDS TO BE DONE ALSO ON ONE WATER CLOSET. (CARRIER MIGHT BE REPLACED IF ADJUSTMENT IS NOT POSSIBLE ) FIELD CONSTRUCTION SHALL VERIFY THIS CONDITION. Nalf,RTR /C coo CAST IRON MATERIAL ti��\ ItiM I T /N I ‘3*'- VI /c/ S qo si\sk CAST IRON MATERIAL k .10 C7 CAST IRON MATERIAL 3 REVISION SANITARY AND VENT PIPING DIAGRAM NOT TO SCALE REVISION ET APPROVED 1 DATE 01.23.02 B ENTERPRISE SECURITY RELOCATION 16919 -20 10.31.12 eL_Air47E.FAW HOT & COLD WATER PIPING DIAGRAM ACCEPTABILITY THIS DESIGN MID /OR SPECIFICATION IS APPROVED APPROVED 9! DEPT. DATE ORAwN 0.t� !HWN11! DAN 'NECKED DAN APPROVED ATE NOT TO SCALE REMOVAL NOTES REMOVE EXIST. PLUMBING FIXTURE (SINK) AND ASSOCIATED APPURTENANCES. REMOVE H &CW TO ABOVE FINISHED CEILING, VENT TO ROOF & WASTE TO BELOW FINISHED FLOOR. CAP WASTE PIPE BELOW FLOOR. PATCH ROOF, WALL Sc FLOOR TO MATCH WITH EXISTING. SEE ARCH. DRAWINGS FOR ROOF, WALL & FLOOR PATCH & FINISH. EXISTING WASTE LINE TO REMAIN ABANDON IN PLACE. EXISTING WASTE LINE TO REMAIN. VIEWED FOR CODE COMPLIANCE APPROVED NOV 2 1 2012 City of Tukwila BUIL._ V cQL. ISION REMOVAL GI NUV 1 3 2012 PERMIT CENTER 90% SUBMITTAL PIPING DIAGRAM NRREM REVISON 16919 -20 904901 DATE 10.31.12 01.23.02 IT'E ENTERPRISE SECURITY RELOCATION MECHANICAL MASTER BUILDING 9 -59.1 DEV. CENTER, WA NEE, M500R 49 ND. 16919 -20 09"P 00 °MG N0' 9- 59 -M500 a'm EXHAUST VENTILATOR (PART OF LIGHT) HVAC PLAN SCALE: 1/4" = 1' -0 -300 CFM AIR HANDLING UNIT TRANE MODEL N o.TYA,0606 - 156 2000 CFM FITTED WITH SMOKE DETECTOR (SEE ELECTRICAL) GENERAL NOTES 1. VD -1: VAV DIFFUSER ACUTHERM MODEL TF -HC, 24 "X24" NOMINAL SIZE. 8" INLET, MIN INLET SP .05 "IN WC" AT 160 CFM & MAX INLET SP 0.18 "IN WG" AT 300 CFM. PROVIDE VD -1 WITH INTEGRAL THERMOSTAT. 2. DUCTWORK CONSTRUCTION TO MATCH EXISTING. 3. PERFORM ALL SHEETMETAL WORK IN ACCORDANCE WITH CURRENT SMACNA STANDARDS. 4. DUCT SEALING SHALL MEET REQUIREMENTS LISTED IN CHAPTER 6 OF IMC AND WASHINGTON STATE ENERGY CODE. 5. CONSTRUCT DUCTS WITH 0 -60 OR BETTER GALVANIZED STEEL (ASTM 527) LFO, CHEM TREAT. 6. SPIN -IN FITTINGS SHALL BE CONICAL TYPE WITH VOLUME DAMPER, AND QUADRANT; FLEX MASTER ELGEN OR EQUNALENT. 7. LOCATE VOLUME DAMPERS AT A POINT WHERE THE DUCT IS ACCESSIBLE; AS FAR FROM THE OUTLET AS POSSIBLE. DAMPERS SHALL BE RUSKIN MD25 OR MDRS25. 8 THOROUGHLY CLEAN ALL DEBRIS FROM THE INSIDE OF ALL DUCTWORK AND PLENUMS. BLOW FREE ALL SMALL PARTICLES OF RUBBISH AND DUST. 9 MECHANICAL DRAWINGS SHOW APPROXIMATE LOCATIONS FOR GRILLES AND DIFFUSERS. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS FOR EXACT LOCATIONS. AFTER SHOP DRAWINGS ARE COMPLETED VERIFY EXACT LOCATION OF GRILLES AND DIFFUSERS IN THE FIELD. ENSURE THAT DIFFUSER AND GRILLE FRAMES MATCH CEILING TYPES AND FINISH PRIOR TO ORDERING. 10. CONNECT FLEXIBLE DUCTS TO METAL DUCTS WITH A SLIP JOINT MADE USING FIRE RESISTANT MASTIC AND CLAMP, IDEAL "SNAP -LOCK" OR VENTLOCK "SURETIGHT NO. 670" AT EACH END. SUPPORT IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS. DO NOT INSTALL WITH ABRUPT BENDS OR OFFSETS. MAXIMUM LENGTH 8 -FEET. LOW PRESSURE INSULATED FLEXIBLE DUCT SHALL BE THERMAFLES MK -E. 11. INSULATE SUPPLY AND RETURN AIR DUCTS. PROVIDE "09" FIBERGLASS INSULATION ON EXTERIOR OF DUCTS PROVIDE INSULATION WITH VAPOR BARRIER. 12. CONSTRUCT DUCTWORK TO THE FOLLOWING SEAL CLASS: DUCTWORK SYSTEM SEAL CLASS A. SUPPLY DUCTWORK A REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2012 City of Tukwila BUILDING DIVISION LEGEND I () I '0 ✓ \ 2 LAMP, 2x4 FLOURESCENT FIXTURE 2 LAMP, Ix4, FLUOR. FIXTURE, SURFACE MOUNT 23 WATT FLUORESCENT TUBE LIGHT EXIT LIGHT 262 DIFFUSER RETURN AIR 2x4 RETURN AIR DUCT CLEANING ACCESS REFERENCE DRAWINGS CONSTRUCTION NOTES CONNECT NEW 10" ROUND DUCT TO EXISTING 14/12 DUCT. RELOCATED THERMOSTAT. LOCATE THERMOSTAT MINIMUM 48" A.F.F. RELOCATED DIFFUSER AND MODIFY THE DUCTWORK TO ACCOMMODATE NEW LOCATION. ® RELOCATED RETURN GRILLE AND ASSOCIATED APPURTENANCES. FOR CEILING DIFFUSER INSTALLATION, SEE DETAIL 14110(6502 REetiv CITY OF TUK ! -^ NUV 1.3 2012 PERMIT CENTER 90% SUBMITTAL 4' 2' 0 2' 4' 8' SCALE: 1/4 " =1' -0" SY 0Y APPROVED DATE SYM 81 DATE A RELOCATE MEDICAL TO 9 -59 BLDG. 110773 -00 D, VILLA 01.23.02 B INSTALL OUTSIDE AR DUCT 1001552591 RW$ 02.14.05 C ENTERPRISE SECURITY RELOCATION 16919 -20 G5 /5AZAN 10.31.12 g)LAi r4 WeAf4 ACCEPTABILITY TH15 DESIGN MID /OR SPECIFICATION 2 APPROVED APPROVED 81 DEPT. DATE DR1*N MAGGIE DITTMAR CRICKED 0MV '21A.INELK CHECKED E 4 -15 -96 12 -21 -01 HVAC PLAN CURRENT REMSUN !SRAM 16919 -20 DATE 10.31.12 01.23.02 APPROVED MECHANICAL MASTER ENTERPRISE SECURITY RELOCATION BUILDING 9 -59.1 COL. ALL DEV. CENTER. WA SHEET 1M10 0D ND 16919 -20 CO NP O. ow5Tro. 09 -059 -1 10 EXISTING 10" SANITARY SEWER EXISTING 18" STORM SEWER 1 1/2" GATE VALVE IN VALVE BOX EXIST. 8" C.W. MAIN z {2) LJ HOT WATER HEATER n_j EXISTING VENT PLUMBING PLAN SCALE: 1/4" = 1' -0" EXISTING 2" VTR 3" FLOOR DRAIN REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2012 City of Tukwila BUILDING DIVISION LEGEND GENERAL NOTE 1. FCO: JR SMITH FIGURE 4020, FINISHED FLOOR CLEANOUT WITH "TWIS —TO— FLOOR" ADJUSTABLE TOPS. REFERENCE DRAWINGS CONSTRUCTION NOTES REGEINiE .i CITY OF TUIKIPII. NOV 1 3 2012 PERMIT CENTER 90% SUBMITTAL 4' 2' 0 2' 4' SCALE: 1/4"=-1'-0" sr REVISION R APP DATE 5Y RE\1SKV 65 APPROVED DATE A RELOCATE MEDICAL TO 9 -59 BLDG. 110773 -00 D. VILLA 01 23.02 B ENTERPRISE SECURITY RELOCATION 16919 -20 GS /SAZAN 10.31.12 ACCEPTABILITY TH15 DESIGN AND /0R SPECIFICATION IS APPROVED APPROVED 0? DEPT. DATE D. VILLA CHECKED APPROVED 1 -08 -02 01.23.02 SUBTRLE PLUMBING PLAN CURRENT RVASION 16919 -20 SYMBOL DA 10.31.12 11 LE MECHANICAL MASTER ENTERPRISE SECURITY RELOCATION BUILDING 9 -59 COL. ALL DEV. CENTER, WA SHEET 1M110 JOB 00, 16919 -20 COMP N0. DWG N0' 09- 059 -1M110 E100E CAST IRON MATERIAL 1 . SPA \ \PEI�I 3' I \l7,yF I \— t • 0 OF'V \SS 01 CAST IRON MATERIAL SANITARY AND VLNT PPM DIAGRAM NOT TO SCALE 70' 41, REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2012 City of Tukwila BUJLDING DIVISION o\S\�\sN(0SEt1F -R CONSTRUCTION NOTES CAPPED PIPE. EXISTING WASTE LINE TO REMAIN ABANDON IN PLACE. LEGEND CW COLD WATER HW HOT WATER SAN SANITARY VTR VENT THROUGH ROOF LAV LAVATORY SINK WC WATER CLOSET (TOILET) — - — — EXISTING NEW — — — EXISTING • BALL VALVE GENERAL NOTES 1. SPACE BELOW THE FLOOR IS VERY LIMITED. ALL UTILITY RUN SHALL BE PROVIDED TO ACCOMPLISHED THE INTENDED DESIGN. 2. PIPE HAS TO BE OFFSETTED TO ACCOMODATE THE ADA REQUIREMENT FOR WALL CLEARANCE, AND DOING SO WILL MAKE THE OTHER WATER CLOSET BE MOVED TOO SINCE THEY ARE BACK TO BACK CARRIER. HEIGHT ADJUSTMENT NEEDS TO BE DONE ALSO ON ONE WATER CLOSET. (CARRIER MIGHT BE REPLACED IF ADJUSTMENT IS NOT POSSIBLE ) FIELD CONSTRUCTION SHALL VERIFY THIS CONDITION. CAST IRON MATERIAL HOT & COLD WATER PIPING DIAGRAM NOT TO SCALE sy REASION or APPROVED DATE s BV APR 02D DATE A RELOCATE MEDICAL TO 9 -59 BLDG 110773 -00 0. V LLA 01.23.02 ENTERPRISE SECURITY RELOCATION 16919 -20 GS /SAJAN 10.31.12 g)LArawAvag ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION 5 APPROvED APPROVED BY DEPT 0RAWN D. VILLA CHECKED TI..INEEN DATE DEN 06E0 ED Duo uaROVED APPRENED CITY OF TUI<W!_'> NUV 1 3 2012 PERMIT CENTER 90% SUBMITTAL] PIPING DIAGRAM CURRENT REMSO 16919 -20 000606 B lore 10.31.12 01.23.02 ENTERPRISE SECURITY RELOCATION BUILDING 9 -59.1 MECHANICAL MASTER DEV. CENTER, WA ET M500 JOB N0 DWG NO. 16919 -20 COMP ND 9- 59 -M500 SoPPY pIR 0 oGT EGtoR oDRA PPL� DG SAD EE DLEG�IO4 z RLE� GoNNELtj0N5 LAS LINE ' I /8� iRpN51n0N JO 00 D(1 moNIN3 600 j5 P N? 0 /6D 1" 60P/ 20 ph p�rEM GO- DETAIL SCALE: NOT TO SCALE 1 1M10 M502 /. RETURN aR PLERuM REVIELNED FOR CODE COMPLIANCE APPROIIED NOV 21 2012 City of Tukwila BUILDING DIVISION MAXIMUM LENGTH 5' SQUARE —TO —ROUND ADAPTOR, SAME MANUFACTURER AS DIFFUSER /— SUPPLY DUCT 4 • !JIB VOLUME DAMPER CEILING SQUARE CEILING DIFFUSER CEILING DIFFUSER DETAIL rn SCALE: NTS 1M10 M502 s REVISION BY APPROVED DATE SYM REVISION BY APPROVED DUE A RELOCATE MEDICAL TO 9 -59 BLDG. 110773 -00 D. VILLA 01.23.02 ENTERPRISE SECURITY RELOCATION 16919 -20 GS /SAZAN 10.31.12 Z,LATL7E4fArig ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN EDUARDO DUARTE t TECRED RECLi CITY OF T:Ita, NOV 1 3 2012 PERMIT CENTER 90% SUBMITTAL GATE 1 -08 -02 SUBTITLE DETAILS CURRENT REVISION 16919 -20 SYMBOL DA 10.31.12 APPROVED BY DEPT. DATE D. VILLA D. VIL CHECKED 01.23.02 APPROVED TIT MECHANICAL MASTER ENTERPRISE SECURITY RELOCATION BUILDING 9 -59 DEV. CENTER, WA ET M502 JOB O. 16919 -20 COMP NO. 0w0 NO. 09- 059 -1M110 (Th �FIeF'�'f,FitC Y� TTC 4 "0 0911 EXIST. (TIC) TELEPHONE TERMINAL I CABINET 0© 0 0 0 0 0 0 0 RJ38X CONN BLOC FOCUS TELCO LINE • TWO LINES TO CENTRAL STATION uM I °,1 HOKE DETECTOR INTERLOCKED W/ THE SUPPLY FAN CONTROLLER PARTIAL PLAN 'JiEW SCALE: 1/4 = 1' -0" • ) 3 l RJ38X CONN BLOC — 120 VAC RISER DIAGRAM REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2012 City of Tukwila BUILDING DIVAS 3 REM510N APPROVED OWE SYM Br APPROVED 017E ENTERPRISE SECURITY RELOCATION 16919 -20 P1 /SAZAN 10.31.12 BOE/A/G ACCEPTABILITY 0195 DESIGN AND /OR SPECIFICATION IS APPROVED ORA . M DITTMAR CNLCKED "GATE LEGEND N m B SMOKE DETECTOR HEAT DETECTOR DUCT DETECTOR COMPUTER OUTLET W/ I/2" EMPTY CONDUIT UP TO CEILING TELEPHONE OUTLET FIRE ALARM HORN MANUAL FIRE ALARM PULL STATION FIRE ALARM CONTROL PANEL GENERAL NOTES 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WARE TO BE /12 THHN /THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/2080 277/48DV "A" PHASE (LEFT BUS 114 PANEL) BLACK BROWN 'B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG —IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) DITTO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REMSED PANEL SCHEDULES UPON COMPLETION OF J08. 9.) VERIFY ROTATION OF ALL 3 PHASE MOTORS. REFERENCE DRAWINGS CONSTRUCTION NOTES RELOCATE EXISTING FIRE ALARM PANEL. SEE DWG 9- 59 -1E6 FOR NEW LOCATION. 'RELOCATE EXISTING ANNUNCIATOR. SEE DWG 9- 59 -1E6 FOR NEW LOCATION.WIRING AS REQUIRED. RELOCATE EXISTING MANUAL FIRE ALARM PULL STATION. SEE DWG 9- 59 -1E6 FOR NEW LOCATION. RELOCATE EXISTING J —BOX SEE DWG 9- 59 -1E6 FOR NEW LOCATION. REMOVE EXISTING DEVICE. MAINTAIN CIRCUIT CONTINUITY TO DOWNSTREAM DEVICES TO REMAIN. REMOVAL RECLiVE0 CITY OF T`IM. NOV 1 3 2012 PERMIT CENTER 90% SUBMITTAL 4' 2' 0 2' 4' 8' SCALE: 1/4".1'-0" 1 -03 -02 SUBTITLE TELEPHONE & FIRE ALARM SYSTEM FIRST FLOOR CURRENT RE.E10N 16919 -20 SYMBOL DATE 10.31.12 APPROVED BY DEPT. DATE E,EUROPA CHECKED APPROVED ITIE ENTERPRISE SECURITY RELOCATION BUILDING 9 -59.1 ELECTRICAL MASTER COL. D.C. Eft 1E6R JOB N0. 16919 -20 COMP NO. D"` NO. 09- 059 -1E6R (5) W/ PHOTO ELECTR. CELL PARTIAL PLAN VIEW SCALE 1/4” = 111 :J REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2012 City of Tukwila BUILDING DIVISION Rteciv CITY OF TI.IKWI. ^. NOV 1 3 2012 PERMIT CENTER LEGEN D: 101 XY ffig EED 01 DmalGO LJ O I-0 LD 2 LAMP, 2x4 FLOURESCENT FIXTURE 3 LAMP, 2x4 FLUORESCENT FIXTURE 'N' DENOTES CIRCUIT NUMBER 'X' DENOTES CENTER LAMP DENOTES OUTSIDE LAMPS 3 LAMP, 2x4 FLUORESCENT FIXTURE W/ BATTERY BACK UP. 1 LAMP. 1x4, FLUORESCENT FIXTURE. THREE WAY SWITCH X' DENOTES CENTER LAMP 'Y' DENOTES OUTSIDE LAMPS JUNCTION BOX RELAY PANEL 000 INTENSITY LIGHT LIGHT, INCANDESCENT EXIT LIGHT EXIT LIGHT, WALL MOUNT JUNCTION BOX 277/480 POWER PANEL PHOTO CELL GENERAL NOTES: I. CONDUIT: 1/2° MINIMUM, 3/4" MINIMUM FOR ALL HOMERUNS. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN /THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250 -57(b) EXCEPTION #1 ,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y /120V 480Y/277V A (LEFT BUS IN PNL) BLACK BROWN B ((CENTER BUS IN PNL) RED ORANGE C RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN /YEL* GRN /YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION /OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. CONSTRUCTION NOTES: REMOVE EXISTING LIGHTING FIXTURE TYPE A, A1, A2, A3, & D. DO NOT DAMAGE. STORE ON SITE FOR REUSE IN NEW RENOVATION. REMOVE EXISTING LIGHTING CONTROL(S) AND ASSOCIATED CONDUIT & CONDUCTORS AS SHOWN. REMOVE EXISTING CONDUIT & CONDUCTORS AS SHOWN. MAINTAIN CIRCUIT CONTINUITY TO DOWNSTREAM LIGHTING FIXTURES TO REMAIN. - ' REMOVE EXISTING LIGHTING FIXTURE AND ASSOCIATED CONDUIT & CONDUCTORS. REMOVE EXISTING EXIT SIGN AND ASSOCIATED CONDUIT & CONDUCTORS. © REMOVE EXISTING EXTERIOR WALL MOUNTED LIGHTING FIXTURE. REMOVE EXISTING COMPACT FLUORESCENT DOWNLIGHT. REMOVAL 90% SUBMITTAL 4' 2' 0 2' 4' 8' SCALE: 1/4"-1'-0" REVISION RELOCATE MEDICAL TO DC 110773 -00 90 E.EUROPA APPROVED DATE sYM REVISION 00 APPROVED DATE I -03 -02 ENTERPRISE SECURITY RELOCATION 16919 -20 PT /SA2AN 10.31.12 g;LAirdirElAW ACCEPTABILITY THIS DESIGN AND /0R SPECIF1CADON IS APPROVED LiYLCW� M. 0 CHECKED ATE SUBTITLE 6 -25 -99 LIGHTING PLAN - FIRST FLOOR CURRFM RBISWN 16919 -20 10.31.12 APPROVED BY DEPT. DATE NUNttN CHECKED APPROVED APPROVED TITLE ENTERPRISE SECURITY RELOCATION BUILDING 9 -59.1 ELECTRICAL MASTER COL D.C. SHEET 1 E 10 R JOB N0. COMP N0. 16919 -20 DWG ND. 09- 059 -1E1OR o to I ',TTY, c�o — `=L �� ii 1.1 l� 110'10' 111 ix o 1Miiiu'I' , �, - ■ i at 4 — -E,_.. L . ! - - - - N AT fi lift". 1 I� J- ^ = • I P. OF 4 Alk. <2 ' .1 1�I s o /Y1 29 .1 : '.- - - -'I CIS �� , — — I I4 � r — JEN lal�Ill' : 1 — �� i, A I ' ���� w jJ I �Iry 4(ul 1!. ■ I CEILING FAN & LCHT 05- 1/13.15 ���W L__ r -` — . es==__ � -.u, T $I( it 1 _ j 5 Da J a 32 i _ � I^ 1 _ _�I r RE`•CRO0 , _ uJ r i ' 9 PANE dF., 1° 41/I 3'.'242' 1? . - „Iv.,_ E� id 1 NS/29 —rOL ,,II LI: : ,, 1,1 . -. � PANEL XP -5 PANEL 05 . AS t"x .RD_,onPm. Te*Mcc PARTIAL PLAN VIEW SCALE 1/4” = 111 :J REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2012 City of Tukwila BUILDING DIVISION Rteciv CITY OF TI.IKWI. ^. NOV 1 3 2012 PERMIT CENTER LEGEN D: 101 XY ffig EED 01 DmalGO LJ O I-0 LD 2 LAMP, 2x4 FLOURESCENT FIXTURE 3 LAMP, 2x4 FLUORESCENT FIXTURE 'N' DENOTES CIRCUIT NUMBER 'X' DENOTES CENTER LAMP DENOTES OUTSIDE LAMPS 3 LAMP, 2x4 FLUORESCENT FIXTURE W/ BATTERY BACK UP. 1 LAMP. 1x4, FLUORESCENT FIXTURE. THREE WAY SWITCH X' DENOTES CENTER LAMP 'Y' DENOTES OUTSIDE LAMPS JUNCTION BOX RELAY PANEL 000 INTENSITY LIGHT LIGHT, INCANDESCENT EXIT LIGHT EXIT LIGHT, WALL MOUNT JUNCTION BOX 277/480 POWER PANEL PHOTO CELL GENERAL NOTES: I. CONDUIT: 1/2° MINIMUM, 3/4" MINIMUM FOR ALL HOMERUNS. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN /THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250 -57(b) EXCEPTION #1 ,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y /120V 480Y/277V A (LEFT BUS IN PNL) BLACK BROWN B ((CENTER BUS IN PNL) RED ORANGE C RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN /YEL* GRN /YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION /OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. CONSTRUCTION NOTES: REMOVE EXISTING LIGHTING FIXTURE TYPE A, A1, A2, A3, & D. DO NOT DAMAGE. STORE ON SITE FOR REUSE IN NEW RENOVATION. REMOVE EXISTING LIGHTING CONTROL(S) AND ASSOCIATED CONDUIT & CONDUCTORS AS SHOWN. REMOVE EXISTING CONDUIT & CONDUCTORS AS SHOWN. MAINTAIN CIRCUIT CONTINUITY TO DOWNSTREAM LIGHTING FIXTURES TO REMAIN. - ' REMOVE EXISTING LIGHTING FIXTURE AND ASSOCIATED CONDUIT & CONDUCTORS. REMOVE EXISTING EXIT SIGN AND ASSOCIATED CONDUIT & CONDUCTORS. © REMOVE EXISTING EXTERIOR WALL MOUNTED LIGHTING FIXTURE. REMOVE EXISTING COMPACT FLUORESCENT DOWNLIGHT. REMOVAL 90% SUBMITTAL 4' 2' 0 2' 4' 8' SCALE: 1/4"-1'-0" REVISION RELOCATE MEDICAL TO DC 110773 -00 90 E.EUROPA APPROVED DATE sYM REVISION 00 APPROVED DATE I -03 -02 ENTERPRISE SECURITY RELOCATION 16919 -20 PT /SA2AN 10.31.12 g;LAirdirElAW ACCEPTABILITY THIS DESIGN AND /0R SPECIF1CADON IS APPROVED LiYLCW� M. 0 CHECKED ATE SUBTITLE 6 -25 -99 LIGHTING PLAN - FIRST FLOOR CURRFM RBISWN 16919 -20 10.31.12 APPROVED BY DEPT. DATE NUNttN CHECKED APPROVED APPROVED TITLE ENTERPRISE SECURITY RELOCATION BUILDING 9 -59.1 ELECTRICAL MASTER COL D.C. SHEET 1 E 10 R JOB N0. COMP N0. 16919 -20 DWG ND. 09- 059 -1E1OR -B00 FOR SURGICAL LIGHT MID FLUOR DOOR OPERATOR SWITCH ri POWER DOOR OPERATOR 65- 1/17.19,21 -1) RESTROOM 0. (2) IFFICE 1 f r c,R001.1- 05- 1/24,26 65- 1/31,33,35 -CAD NvEr EMERr - 1/37,39,41 P -5/6 -1/28 CLOSE F"-1 6 FOR REFRIG. N5 -1/ 12' MT 12"MT 49.641 PARTIAL PLAN VIEW 12*APF 4973F SCALE: 1/4" O REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2012 City of Tukwila BUILDING DIVISION LEGEND: FS 15A, 125V, I PHASE, DUPLEX RECEPTACLE cFG 15A, GROUND FAULTACIRCUITLPROT PROTECTION W / /1 WEATHER PROOF Ittr X%/NFEP ISA, 125V, I PHASE, 4 —PLEX RECEPTACLE 15A, 125V, 1 PHASE, DUPLEX FLOORSTACK 120/208V DISTRIBUTION PANEL DISCONNECT SWITCH, NON— FUSED, XX AMPERES JUNCTION BOX GENERAL NOTES: I. CONDUIT: 1/2" MINIMUM, 3/4" MINIMUM FOR ALL HOME RUNS. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN /THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250 -57(b) EXCEPTION #I,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A LEFT BUS IN PNL) BLACK BROWN B CENTER BUS IN PNL) RED ORANGE C RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN /YEL. GRN /YEL. *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION /OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 16 ] ALL CONDUIT, TO BE RIGID AND ALL CONDUIT, FITTINGS AND RECEPTACLES TO BE SURFACE MOUNTED IN INDICATED ROOMS. CONSTRUCTION NOTES: REMOVE EXISTING FLOOR RECEPTACLE. PROVIDE BLANK COVER AS REQUIRED. REMOVE EXISTING CONDUCTORS BACK TO FIRST ACCESSIBLE JBOX. REMOVE EXISTING RECEPTACLE. MAINTAIN CIRCUIT CONTINUITY TO DOWNSTREAM RECEPTACLES & DEVICES TO REMAIN. REMOVE EXISTING RECEPTACLES, DEVICES, & ASSOCIATED RACEWAY & CONDUCTORS AS SHOWN. REMOVAL Rteti I) CITY OF TtlKt 9?_ ^. NOV 1 3 2012 PERMIT CENTER 90% SUBMITTAL 4' 2' 0 2' 4' 8' SCALE: 1/4". 1'-0" s REVISION A RELOCATE MEDICAL TO DC 11077300 By E. EUROPA APPROVED BY B DESIGN CAHNGES C ENTERPRISE SECURITY RELOCATION MEG 16919 -20 PT /SAZAN CAS 4/5/02 10.31.12 �BOE //VG® ACCEPTABILITY THIS DESIGN MID /OR SPECIFICATION 5 APPROVED M. DITTMAR LNLCKLU 6 -25 -99 suBrRUE 120V/208V POWER PLAN - FIRST FLOOR CURRENT RLMSON 5YMOOL 16919 -201 IC wTE 10.31.12 1Nt,INLLN EUROPA 'CHECKED 1/21/02 APPROAO APPROVED ELECTRICAL MASTER ENTERPRISE SECURITY RELOCATION BUILDING 9 -59.1 COL. D.C. sNEEI 1E6OR roe No. 1001. o. 16919 -20 JCO N--- 0w4NO' 09- 059 -1E6OR PARTIAL PLAN VIEW SCALE: 1/4" = 1' -0" EXIST. (TTC) TELEPHONE TERMINAL CABINET TWO LINES TO CENTRAL STATION 2 ) ,SMOKE DETECTOR NTERLOCKED W/ THE SUPPLY FAN CONTROLLER TELCO LINE RJ38X CONN BLOCK RJ38X CONN BLOC FOCUS — 120 VAC RISER DIAGRAM REVIEliva) FOR CODE COMPLIANCE APPROV=ED NOV 21 2012 City of TuivAtila BUILDING DIVISION REVISION BY APPROVED DATE APPROVED DATE ENTERPRISE SECURITY RELOCATION 16919 -20 PT /SAZAN 10.31.12 g:LATL7AWIW ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION 15 APPROVED DRAWN M. DITTMAR CHECKED b LEGEND SMOKE DETECTOR HEAT DETECTOR DUCT DETECTOR DATA OUTLET W/ 1/2" CONDUIT UP TO CEILING UNLESS OTHERWISE NOTED. TELEPHONE OUTLET FIRE ALARM HORN MANUAL FIRE ALARM PULL STATION B FIRE ALARM CONTROL PANEL GENERAL NOTES 1.) ALL CONDUIT TO BE 1/2' EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE #12 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/2080 277/4600 "A' PHASE (1140 BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C' PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 41 LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER IISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG —IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) 05340 LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH ORCUIT IDENTIFICATION. 8.) INSTALL REMSED PANEL SCHEDULES UPON COMPLETION OF JOB, 9.) VERIFY ROTATION OF ALL 3 PHASE MOTORS. REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE DATA OUTLET & 1 "C WITH PULL STRING TO ACCESSIBLE CEILING SPACE. PROVIDE DATA OUTLET. COORDINATE WITH FURNITURE SUPPLIER. PROVIDE JBOX FOR DATA CONNECTION AT FURNITURE. PROVIDE 1 "C WITH PULL STRING TO ACCESSIBLE CEILING SPACE. ® RELOCATE EXISTING SURFACE MOUNTED ARE ALARM PANEL (FACP). EXTEND EXISTING CIRCUITS TO NEW LOCATION. RELOCATE EXISTING ANUNNCIATOR. EXTEND EXISTING CIRCUITS TO NEW LOCATION. PROVIDE JBOX AS REQUIRED TO MAINTAIN CIRCUIT CONTINUITY TO DOWNSTREAM DEVICES TO REMAIN. INTERCEPT EXISTING CIRCUITS ABOVE CEILING & PROVIDE NEW 12 "x16 "x14" NEMA 1 JBOX IN ACCESSIBLE LOCATION. CITY OF T !O, r'.. NOV 1,3 2012 PERMIT CENTER 90% SUBMITTAL 4' 2' 0 2' 4' 8' SCALE: 1/4"=1'-0" 03 -02 SUBTITLE TELEPHONE & FIRE ALARM SYSTEM FIRST FLOOR CURRENT REVISION 16919 -20 SYMBOL w 10.31.12 APPROVED BY DEPT. DATE LNI.INELH E.EUROPA CHLCKED APPROVED TITLE ENTERPRISE SECURITY RELOCATION BUILDING 9 -59.1 ELECTRICAL MASTER COL. D.0 1E6 JOB N0. 0 16919 -20 COMP N DWG NO. 09- 059 -1E6 T W/ PHOTO ELECTR. CELL'1 / 1 (p PARTIAL PLAN VIEW SCALE: 1/4" = 1' -0" 2) CONSTRUCTION NOTES: PROVIDE CEILING MOUNTED LOW VOLTAGE MULTI - TECHNOLOGY OCCUPANCY SENSOR. PROVIDE WALL MOUNTED LOW VOLTAGE MULTI - TECHNOLOGY OCCUPANCY SENSOR. PROVIDE LOW VOLTAGE POWER SUPPLY /RELAY AS REQUIRED ABOVE CEILING 114 ACCESSIBLE LOCATION. ® REMOVE CENTER LAMP & LAMP SOCKETS FROM EXISTING 3 -LAMP LIGHTING FIXTURE AND REINSTALL LIGHTING FIXTURE WITH TWO OUTBOARD LAMPS AS SHOWN. PROVIDE NEW RACEWAY & CONDUCTORS AS REQUIRED. REINSTALL EXISTING 2 -LAMP FLUORESCENT LIGHTING FIXTURE AS SHOWN. PROVIDE NEW RACEWAY & CONDUCTORS AS REQUIRED. © REINSTALL EXISTING 2 -LAMP FLUORESCENT LIGHTING FIXTURE WITH SELF CONTAINED BATTERY BACKUP AS SHOWN. PROVIDE UNSWITCHED CONDUCTORS FOR NIGHT LIGHT OPERATION. PROVIDE NEW RACEWAY & CONDUCTORS AS REQUIRED. INTERCEPT EXISTING LIGHTING CIRCUIT & EXTEND TO RELOCATED LIGHTING FIXTURES AS SHOWN. ® PROVIDE NEW 277V, 1 -POLE LIGHT SWITCH & ELECTRICAL CONNECTION FOR EXISTING CEILING FAN & LIGHT. PROVIDE NEW RACEWAY & CONDUCTORS AS REQUIRED. PROVIDE NEW RECESSED CEILING MOUNTED COMPACT FLUORESCENT DOWNLIGHT WITH SELF CONTAINED BATTERY BACKUP. PRESCOLITE # CFT626- DYL- EM- STF602- WT- B6- LP26135 OR APPROVED EQUAL. PROVIDE NEW EXTERIOR COMPACT FLUORESCENT WALL SCONCE WITH 0 -DEG F SELF CONTAINED BATTTERY BACKUP & CONNECT TO EXISTING PHOTOCELL CONTROLLED EXTERIOR LIGHTING CIRCUIT. PEV1EWED FOR CODE COMPLIANCE A P? tPA�;F r) l` a?; t NOV 2 1 7q1? LEGEND: ® 1 LAMP, 1x4, FLUORESCENT FIXTURE. I I x$ 2 LAMP, 2x4 FLOURESCENT FIXTURE ! 3 LAMP, 2x4 FLUORESCENT FIXTURE EMERGENCY LIGHTING FIXTURE W/ SELF CONTAINED BATTERY BACK UP. TYPE AS NOTED. SINGLE POLE TOGGLE SWITCH - "X" INDICATES QUANTITY x$3 3 -WAY SWITCH - "X" INDICATES QUANTITY. m JUNCTION BOX ERJ RELAY PANEL ID HIGH INTENSITY LIGHT J LIGHT, INCANDESCENT O EXIT LIGHT I-0 EXIT LIGHT, WALL MOUNT CD JUNCTION BOX ® 277/480 POWER PANEL P ,E, EXTERIOR WALL MOUNTED LIGHTING FIXTURE WITH SELF CONTAINED BATTERY BACKUP. TYPE AS NOTED. ® w WALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR - WATTSTOPPER #LMDX -100 OR APPROVED EQUAL. CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR - WATTSTOPPER #LMDC -100 OR APPROVED EQUAL. ® DIGITAL ON /OFF ROOM CONTROLLER. WATTSTOPPER #LMRC -102 SERIES OR APPROVED EQUAL. — - — LOW VOLTAGE PLENUM RATED CABLE PER LIGHTING CONTROL SUPPLIER RECOMMENDATION. GENERAL NOTES: 1. CONDUIT: 1/2" MINIMUM, 3/4" MINIMUM FOR ALL HOMERUNS. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250 -57(b) EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) BLACK BROWN B 0 (CENTER BUS IN PNL) RED ORANGE C 0 (RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN /YEL' GRN/YEL" 'GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION /OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON La • • 0 6. PROVIDE UNSWTICHED CONDUCTORS TO EXIT SIGNS AND EMERGENCY LIGHTING FIXTURES FOR CIRCUIT MONITORING. CITY OF TLIKV115I_ A. NOV 1 3 2012 PERMIT CENTER 90% SUBMITTAL 4' 2' 0 2' 4' 8' SCALE: 1/4".1' -0" REVISION BY APPROVED 0■10 55 APPROVED RELOCATE MEDICAL TO DC 110773 -00 E.EUROPA 01 -03 -03 ENTERPRISE SECURITY RELOCATION 16919 -20 PT /SAZAN 10.31.12 BOE /NG® ACCEPTABILITY THIS DESIGN MID /OR SPECIFICATION IS APPROVED M. DITTMAR CHECKED 01 -03 -02 SUBTITLE LIGHTING PLAN - FIRST FLOOR CURRENT REV.. 16919 -20 DA 10.31.12 APPROVED BY DEPT NIANLEM DATE E. EUROPA CHECKED APPROVED APPROVED TITLE ENTERPRISE SECURITY RELOCATION BUILDING 9 -59.1 ELECTRICAL MASTER COL. D.0 SHEET 1E10 JOB NO 16919 -20 00MP N0. DWG NO. 09- 059 -1E10 .tea r1 • K 1110 I lb l 1.,_-_,g T c I '. �1 lb / 5 10 '■ I \ '1YP. OF 4 T c 1 -26 - - 2 .6 i L�' 2 D r_. III �.— - —1— 3„ I © [II d 36 ....! 111 I TYP 1 - - - -- 1 �171�� I sago { T � r_�MINIM r=:_ -: CEILING 0 ���... FAN & LIGHT i� �cl 77 flL±Rsl/l3.1s h'E IC 11 �I 1 951 I' i PANE `�'EC N5 -LLEC I �©k 3 u IA/3 IJAN(T ,y,.- I e1 el 445/ D J II At ill 3 PANEL XP-5 PANEL 95 45 PVA 4R0- 120/208V TRANSF. PARTIAL PLAN VIEW SCALE: 1/4" = 1' -0" 2) CONSTRUCTION NOTES: PROVIDE CEILING MOUNTED LOW VOLTAGE MULTI - TECHNOLOGY OCCUPANCY SENSOR. PROVIDE WALL MOUNTED LOW VOLTAGE MULTI - TECHNOLOGY OCCUPANCY SENSOR. PROVIDE LOW VOLTAGE POWER SUPPLY /RELAY AS REQUIRED ABOVE CEILING 114 ACCESSIBLE LOCATION. ® REMOVE CENTER LAMP & LAMP SOCKETS FROM EXISTING 3 -LAMP LIGHTING FIXTURE AND REINSTALL LIGHTING FIXTURE WITH TWO OUTBOARD LAMPS AS SHOWN. PROVIDE NEW RACEWAY & CONDUCTORS AS REQUIRED. REINSTALL EXISTING 2 -LAMP FLUORESCENT LIGHTING FIXTURE AS SHOWN. PROVIDE NEW RACEWAY & CONDUCTORS AS REQUIRED. © REINSTALL EXISTING 2 -LAMP FLUORESCENT LIGHTING FIXTURE WITH SELF CONTAINED BATTERY BACKUP AS SHOWN. PROVIDE UNSWITCHED CONDUCTORS FOR NIGHT LIGHT OPERATION. PROVIDE NEW RACEWAY & CONDUCTORS AS REQUIRED. INTERCEPT EXISTING LIGHTING CIRCUIT & EXTEND TO RELOCATED LIGHTING FIXTURES AS SHOWN. ® PROVIDE NEW 277V, 1 -POLE LIGHT SWITCH & ELECTRICAL CONNECTION FOR EXISTING CEILING FAN & LIGHT. PROVIDE NEW RACEWAY & CONDUCTORS AS REQUIRED. PROVIDE NEW RECESSED CEILING MOUNTED COMPACT FLUORESCENT DOWNLIGHT WITH SELF CONTAINED BATTERY BACKUP. PRESCOLITE # CFT626- DYL- EM- STF602- WT- B6- LP26135 OR APPROVED EQUAL. PROVIDE NEW EXTERIOR COMPACT FLUORESCENT WALL SCONCE WITH 0 -DEG F SELF CONTAINED BATTTERY BACKUP & CONNECT TO EXISTING PHOTOCELL CONTROLLED EXTERIOR LIGHTING CIRCUIT. PEV1EWED FOR CODE COMPLIANCE A P? tPA�;F r) l` a?; t NOV 2 1 7q1? LEGEND: ® 1 LAMP, 1x4, FLUORESCENT FIXTURE. I I x$ 2 LAMP, 2x4 FLOURESCENT FIXTURE ! 3 LAMP, 2x4 FLUORESCENT FIXTURE EMERGENCY LIGHTING FIXTURE W/ SELF CONTAINED BATTERY BACK UP. TYPE AS NOTED. SINGLE POLE TOGGLE SWITCH - "X" INDICATES QUANTITY x$3 3 -WAY SWITCH - "X" INDICATES QUANTITY. m JUNCTION BOX ERJ RELAY PANEL ID HIGH INTENSITY LIGHT J LIGHT, INCANDESCENT O EXIT LIGHT I-0 EXIT LIGHT, WALL MOUNT CD JUNCTION BOX ® 277/480 POWER PANEL P ,E, EXTERIOR WALL MOUNTED LIGHTING FIXTURE WITH SELF CONTAINED BATTERY BACKUP. TYPE AS NOTED. ® w WALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR - WATTSTOPPER #LMDX -100 OR APPROVED EQUAL. CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR - WATTSTOPPER #LMDC -100 OR APPROVED EQUAL. ® DIGITAL ON /OFF ROOM CONTROLLER. WATTSTOPPER #LMRC -102 SERIES OR APPROVED EQUAL. — - — LOW VOLTAGE PLENUM RATED CABLE PER LIGHTING CONTROL SUPPLIER RECOMMENDATION. GENERAL NOTES: 1. CONDUIT: 1/2" MINIMUM, 3/4" MINIMUM FOR ALL HOMERUNS. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250 -57(b) EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) BLACK BROWN B 0 (CENTER BUS IN PNL) RED ORANGE C 0 (RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN /YEL' GRN/YEL" 'GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION /OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON La • • 0 6. PROVIDE UNSWTICHED CONDUCTORS TO EXIT SIGNS AND EMERGENCY LIGHTING FIXTURES FOR CIRCUIT MONITORING. CITY OF TLIKV115I_ A. NOV 1 3 2012 PERMIT CENTER 90% SUBMITTAL 4' 2' 0 2' 4' 8' SCALE: 1/4".1' -0" REVISION BY APPROVED 0■10 55 APPROVED RELOCATE MEDICAL TO DC 110773 -00 E.EUROPA 01 -03 -03 ENTERPRISE SECURITY RELOCATION 16919 -20 PT /SAZAN 10.31.12 BOE /NG® ACCEPTABILITY THIS DESIGN MID /OR SPECIFICATION IS APPROVED M. DITTMAR CHECKED 01 -03 -02 SUBTITLE LIGHTING PLAN - FIRST FLOOR CURRENT REV.. 16919 -20 DA 10.31.12 APPROVED BY DEPT NIANLEM DATE E. EUROPA CHECKED APPROVED APPROVED TITLE ENTERPRISE SECURITY RELOCATION BUILDING 9 -59.1 ELECTRICAL MASTER COL. D.0 SHEET 1E10 JOB NO 16919 -20 00MP N0. DWG NO. 09- 059 -1E10 (D DOOR OPERATOR o SWITCH POWER DOOR OPERATOR ° XP -5/4 N5- 1/17,11 "21 FIRE ALARM ANNUNCIATOR XP -5/2 IRESTROOM N5 -1/1,3 NN5 1Db MECH ELECT J.ANITORI L N5 -1 ROOM 45 VVA XFOFMER N5 -1/29 N5 -1/24 65- 1/31,33,35 IT —NO- 1/37,39,41 N5 -1/ FOR REFRIG. 12' AFT 1 COUNTER 12 "AFT 48'AFF PARTIAL PLAN VIEW "AFT 48"AFF SCALE: 1/4 1 REV EwE OR CODE COMPLIANCE APPROVED NOV 21 2012 City of Tukwila BUILDING DIVISION I SY REVISION 8r APPROVED REVS By APPROED DATE A RELOCATE MEDICAL TO DC 11077300 E. EUROPA 8 DESIGN CAHNGE5 M85 4/5/02 ENTERPRISE SECURITY RELOCATION 16919 -20 PT /SAZAN 10.31.12 ACCEPTABILITY TN15 DESIGN AND /OR SPECIFICATION 15 APPROVED DRAWN M. DITTMAR CNECNED LEGEND: tb4 GFC 1 /P 14 v XX /NFCP 15A, 125V, 1 PHASE, DUPLEX RECEPTACLE 15A, 125V, 1 PHASE, DUPLEX RECEPTACLE W/ GROUND FAULT CIRCUIT PROTECTION & WEATHER PROOF 15A, 125V, 1 PHASE, 4 —PLEX RECEPTACLE 15A, 125V, 1 PHASE, DUPLEX FLOORSTACK 120/208V DISTRIBUTION PANEL DISCONNECT SWITCH, NON— FUSED, XX AMPERES 0 Q DUPLEX OR TRIPLEX RECEPTACLE. COORDINATE WITH FURNITURE SUPPLIER. FURNITURE FEED CONNECTION. COORDINATE WITH FURNITURE SUPPLIER. 1 1 0 y...AtG 1. CONDUIT: 1/2" EMT MINIMUM, 3/4" EMT MINIMUM FOR ALL HOME RUNS UNLESS OTHERWISE NOTED. U S OW 1 ,' G, INSULATION TYPE THHN /THWN, UNLESS OTHERWISE NOTED. 01 I • 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250 -57(b) EXCEPTION fl1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 LEFT BUS IN PNL) BLACK BROWN B 0 CENTER BUS IN PNL) RED ORANGE C 0 RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN /YEL' GRN /YEL" 'GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION /OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 6 ALL CONDUIT, TO BE RIGID AND ALL CONDUIT, FITTINGS AND RECEPTACLES TO BE SURFACE MOUNTED IN INDICATED ROOMS. CONSTRUCTION NOTES: I>. INTERCEPT EXISTING CIRCUIT(S) & EXTEND TO NEW RECEPACLES AS SHOWN. PROVIDE NEW J80X IN ACCESSIBLE LOCATION. INTERCEPT EXISTING CIRCUIT & EXTEND TO NEW RECEPTACLE(S) AS SHOWN. PROVIDE NEW NEMA 5 -20R AS SHOWN. ® ELECTRICAL CONTRACTOR (SHALL COORDINATE FURNITURE CONNECTIONS WITH FURNITURE INSTALLATION. PROVIDE ELECTRICAL CONNECTIONS. CONTRACTOR SHALL INSTALL WIRING DEVICES IN SYSTEM FURNITURE. PROVIDE NEW NEMA 5 -20R MOUNTED 12" ABOVE COUNTER. PROVIDE NEMA 5 -20R GFCI RECEPTACLE MOUNTED 12" ABOVE COUNTER. RkC6 1S CITY OF NOV 1 3 2012 . PERMIT CENTER 90% SUBMITTAL 4' 2' 0 2' 4' 8' SCALE: 1/4"-l'—o" TE 6 -25 -99 SUBTITLE 120V/208V POWER PLAN - FIRST FLOOR CURRENT 8846 ON 16919 -20 500801 DA 10.31.12 APPROVED BY DEPT. DATE EUROPA 'RE1NID 1/21/02 APPROVED LE ENTERPRISE SECURITY RELOCATION BUILDING 9 -59.1 ELECTRICAL MASTER COL. D.0 SHEET 1 E60 JOB N0. 16919 -20 COOP N0. IMO ND. 09- 059 -1E60 LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING LAMPS VOLTAGE LAMPS INPUT WATTS MANUFACTURERS CATALOG SERIES NUMBER REMARKS SYMBOLS /T'\ 32 2' x 4' RECESSED PARABOLIC FLUORESCENT, 3" DEEP, 24 CELL FIXTURE DETAIL 1 THIS SHT. 32 W F32 T8/TL835 2950 LUM 277 V 97 AVERAGE PER FIX. COLUMBIA P2 24 332G -SP 3X6 -S -EB8 277 -GLR Al 2' x 4' RECESSED PARABOLIC LOUVER, 3" DEEP, 12 CELLS DETAIL 1 THIS SHT. 32 W F32 T8/TL835 2950 LUM 277 V 64 AVERAGE PER FIX. COLUMBIA P2 24 232G -SP 2X6 -S -EB8 277 -GLR I 1 -2,:22 /7,-2 2' x 4' RECESSED PARABOLIC LOWER, 3" DEEP, 18 CELLS DETAIL 1 THIS SHT. 32 W F32 T8/TL835 2950 LUM 277 V 97 COLUMBIA P2 24 332G -SP 3X6 -S -EB8 277 - GLR -EL WITH EMERGENCY BATTERY PACK o .'`32 /'\ 2,..P 2' x 2' RECESSED PARABOLIC LOWER, 3" DEEP, 9 CELLS DETAIL 1 THIS SHT. 32 W F32 T8 /TL835 2950 LUM 277 V 64 COLUMBIA P2 24 2 32U6 G -SP 3X3 -S -EB8 277 - GLR -EL WITH EMERGENCY BATTERY PACK o C C-w i 6-5/8" FLUORESCENT DOWNLIGHT /S'ECULAR CLEAR ALZAK REFLECTOR CEILING RECESSED 26 WATT QT COMPACT FLUOR. 277 V 39 PRESCOLITE . CFT632EB- STF602 /B24 n PENDANT MOUNTED WITH FLUORESCENT LAMP 26 WATT OUAD 4 -PIN, ELECTRONIC BALLAST 277 V 39 DAC LIGHTING DS5170 -1F26- 277 -MG -BL 10 I 34 /'\ FLUORESCENT EXIT SIGN GREEN LETTERS ON WHITE BACKGROUND, STENCIL STYLE, WALL 6 WATT F6T5 (OWNER) 277 V 20 DUAL -LATE L2 SGW -E -277 /7A 2,-34 HPS WALL MOUNTED FIXTURE W/ POLYCARBONATE REFRACTOR WALL 70 WATT HPS 277V 90 LITHONIA TWA70S -277 �. ■ WALL MOUNTED CYLINDER WHITE POLYCARBONATE WALL 13 WATT 277 V 20 PRESCOLITE TS /WB134 -277 WITH PE CELL /7 PENDANT MOUNTED FLUORESCENT INDUSTRIAL TYPE PENDANT 32 W F32 T8/TL835 150 U 277 V 64 COLUMBIA CSR 4 232 SLR -EB8- 277 - GLR -EL (2) SAME FIXTURES EXCEPT ONE WITH EMERGENCY BATTERY PACK I � E Z=13 3 I /71 UNIVERSAL MOUNT LED EXIT SIGN SELF CONTAINED BATTERY BACKUP SELF TEST /SELF DIAGOSTICS SURFACE LED MVOLT 3.5 DUAL -LITE LX- U- G -W -E -I 1 3"5 1/7 \ EXTERIOR WALL MOUNT, FULL CUTOFF, LENSED, GASKETED, COMPACT FLUOR SCONCE WITH SELF CONTAINED BATTERY BACKUP. INTEGRAI PHOTOCFII SURFACE CFTR42W 35K 277 V 46 LITHONIA WST- 42TRT- MD- 120 - ELDWD -PC WITH EMERGENCY BATTERY PACK AND INTEGRAL PHOTOCELL 1 rinel 1,/ PANEL N5 -1 TO 9 -50 BLDG. SEE 9- 50 -1E111 ONE LINE DIAGRAM SCALE: NONE FIXTURE SUPPORT 'WIRE (TYP) 1/2" FLEXIBLE STEEL CONDUIT TO J -BOX (6" MAX. LENGTH) FIXTURE CEILING SUPPORT GRID TYPICAL RECESSED FIXTURE INSTALLATION DETAIL SCALE: NONE E- j900 1 CEILING TILE Rd_VIE. TotfEL, i'OR CODE COMPLIANCE APPROVED NOV 21 2012 City of Tukwila BUILDING DIVISION CITY OF TtUKV_'.. ". NOV 1 3 2012 PERMIT CENTER 90% SUBMITTAL SY REVISION BY APPROVED DATE SYM REVS APPROVED LATE A ENTERPRISE SECURITY RELOCATION 16919 -20 PT /SAZAN 10.31.12 Z)LAnsttc-Avga ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED ORAWN M. DITTMAR T:HECRED 01.04.02 stoma ELECTRICAL SCHEDULES & ONE -LINE DIAGRAM CURRENT REVISION 16919 -20 SYABOL cwn 10.31.12 APPROVED BY DEPT. DATE EUROPA CHECKED JOHN J.oVAVREK APPROVED 01/23/02 Trt ELECTRICAL MASTER ENTERPRISE SECURITY RELOCATION BUILDING 9 -59.1 COL. X -0 /0 -0 DEV. CENTER, WA E500 JOB N0. 16919 20 COMP No. owc No. 09- 059 -E500 1 HERMIT CORD COP'S PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -176 DATE: 11/13/12 PROJECT NAME: BOEING #9 -59 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: AT A-tc Building Division Public Works NIA 04(2. �2 Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 11/15/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ DUE DATE: 12/13/12 Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit: Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople *ter Friendly Page General /Specialty Contractor A business registered as a construction contractor with L8J to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name AUBURN MECHANICAL INC UBI No. 600074968 Phone 2538389780 Status Active Address Po Box 249 License No. AUBURMI163BA Suite /Apt. License Type Construction Contractor City Auburn Effective Date 1/1/1984 State WA Expiration Date 9/12/2014 Zip 98071 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AUBURMI184LAAUBURN MECHANICAL INC Construction Contractor Plumbing Unused 6/1/1982 1/1/1984 Archived Business Owner Information Name Role Effective Date Expiration Date THODAY, DAVID V President 01/01/1980 Amount JOHNSON, STACY ANNE President 01/01/1980 DTC08057R723PHX12 JOHNSON, KIM PAUL Secretary 02/06/2009 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 FIDELITY Et DEPOSIT CO OF MD LPM8047218 09/01/2001 Until Cancelled $12,000.00 09/12/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 29 Phoenix Insurance Company, The DTC08057R723PHX12 10/01/2012 10/01/2013 $1,000,000.00 09/25/2012 28 Phoenix Insurance Company, The DTC08057R723PHX11 10/01/2011 10/01/2012 $1,000,000.00 09/20/2011 27 PHOENIX INS CO DTC08057R723PHX10 10/01/2010 Until Cancelled $1,000,000.0009 /27/2010 26 Continental Western Ins Co CWP258632926 10/01/2009 10/01/2010 $1,000,000.00 10/05/2009 25 CONTINENTAL WESTERN INS CO CWP258632923 09/01/2008 09/01/2009 $1,000,000.00 08/28/2008 24 CONTINENTAL WESTERN CWP2586329 09/01/2005 09/01/2008 $1,000,000.00 08/13/2007 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 11/26/2012