Loading...
HomeMy WebLinkAboutPermit M12-184 - CENTURY LINKCENTURY LINK 6101 S 180 ST M12 -184 City of/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 3523049120 Address: 6101 S 180 ST TUKW Project Name: CENTURY LINK Permit Number: M12 -184 Issue Date: 01/11/2013 Permit Expires On: 07/10/2013 Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKWILA WA 98138 Contact Person: Name: JOSHUA BORDO Address: 20109 144 AV NE , WOODINVILLE WA 98072 Email: NOT PROVIDED Contractor: Name: JOHANSEN MECHANICAL INC. Address: P.O. BOX 1768 , WOODINVILLE, WA 98072 Contractor License No: JOHANMI173PK Phone: 425 -527 -1006 Phone: 425 481 -2266 Expiration Date: 02/02/2013 DESCRIPTION OF WORK: MODIFY EXISTING DUCT AND TWO NEW GRILLES PER PLAN Value of Mechanical: $3,932.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $233.13 International Mechanical Code Edition: 2009 Date: (‘—'1 I v l I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Date: / Print Name: �i Dr,g v // This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doe: IMC -4/10 M12 -184 Printed: 01 -11 -2013 PERMIT CONDITIONS Permit No. M12-184 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -184 Printed: 01 -11 -2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: s--)-(p (For ofce use only) r.� MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION King Co Assessor's Tax No.: 35 23 01(4/ 2-0 Site Address: (O /OI 5o,.cyti. % .S72-4, TA 12 1 c, , L►41- Suite Number: Floor: Tenant Name: CP..t �.� Lrl'1 New Tenant: ❑ Yes QL.No PROPERTY OWNER Name: - os o_ 3-J o Name: Sey`.- ic.WopPSfieS 1LG Address: Address: 40/0/ S, / , Phone: y2S.- 5_2_7 - A/069 Fax: City-17414.0,14. Email: State: W4 Zip: %P.8", CONTACT PERSON - person receiving all project communication Name: - os o_ 3-J o Address: 70/067 /V it.- Ave ..4)e: Address: Phone: Gj2�16 —2-2 —G pax: y2-3= yafp -COi33 City: State: Zip: Phone: y2S.- 5_2_7 - A/069 Fax: Email: MECHANICAL CONTRACTOR INFORMATION Company Name: J0/144 44 cen ,/ / tit /�( r'G.,t . 'c , I Address: 70/067 /V it.- Ave ..4)e: City: State: Zip: /,(%v���u�ll� �//� of CrO?2. Phone: Gj2�16 —2-2 —G pax: y2-3= yafp -COi33 Contr Reg No.: j Offjtvm_ri%3t 1'I Date: 22`2013 Tukwila Business License No.: 1.5“.0 —OlD/ 2& Z Valuation of project (contractor's bid price): $ 3,43,3 2P OU Describe the scope of work in detail: // (Mo(,Gt 1L CKe ?'Al1j D& 1 /�4t.t.t 1.J 1) 1'0( LS ?L'1" ?le-A, Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas ❑ Other: H:\Applications\Fomis- Applications On Line\2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type " Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall /floor mounted heater Appliance vent 1 Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfin Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system 1 Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type QtY Fire damper Diffuser a2 Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty' 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO IZE AGENT: Signature: _ Date: /1— Zfo lZ Print Name: c_30,S L ci ) r &v Day Telephone: 442,5"-- .6;2 — /GZ?[(; Mailing Address: 020/09 /'IWi. _4. ./Ur- H:\ Applications\Forms- Applications On Line \20I 1 Apphcat,ons\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh (ical t °14'07 Z City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 3523049120 Permit Number: M12 -184 Address: 6101 S 180 ST TUKW Status: PENDING Suite No: Applied Date: 11/26/2012 Applicant: CENTURY LINK Issue Date: Receipt No.: R12 -03180 Initials: User ID: WER 1655 Payment Amount: $233.13 Payment Date: 11/26/2012 11:32 AM Balance: $0.00 Payee: JOHANSEN MECHANICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 060182 233.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 186.50 000.345.830 46.63 Total: $233.13 rinr.• Rarpint -n8 Printprl• 11_98 -9(117 INSPECTION RECORD Retain a copy with permit INSPECTION :NO: PERMIT NO. ;CITY OF.TUKWILA BUILDING DIVISION 6300 Southcenter Blvd:, #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 M 2--tg 4- Project,.. — Type c...-Insp e c ion: Address: n�– Date Called: Special Instructions: Date Wanted:. (s ..a.m. (3 p.m. Requester: Phone No:(4 3 n /j-2-2 Approved Per applicable codes; EJCorrections required prior to approval. 3 COMMENTS: r A-_ <?, t- m- ; 4-- Ct►.p I-� Inspector) Date: RE INSPECTION FEE REQUIRED. Prior to next inspection, fee must be aid.at 6300 Southcenter Blvd., Suite 106. Call to schedule reinspection. %WOO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -184 PROJECT NAME: CENTURY LINK SITE ADDRESS: 6101 S 180 ST X Original Plan Submittal Response to Incomplete Letter # DATE: 11 -26 -12 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building 'Division 1�� v` Public Works ❑ Fire Prevention Structural ❑ Planning Division Permit Coordinator fll DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 11 -27 -12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: DUE DATE: 12 -25 -12 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople P ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name JOHANSEN MECHANICAL INC UBI No. 600495164 Phone 4254812266 Status Active Address 20109 144Th Ave Ne License No. JOHANMI173PK Suite /Apt. License Type Construction Contractor City Woodinville Effective Date 10/12/1983 State WA Expiration Date 2/2/2013 Zip 98072 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status ADJOHC*176ND A D JOHANSEN CO Construction Contractor General Unused 8/4/1983 7/26/1984 Archived Business Owner Information Name Role Effective Date Expiration Date JOHANSEN, ALLEN D Cancel Date 01/01/1980 Bond Amount JOHANSEN, ANITA J 9 01/01/1980 275167C Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 9 DEVELOPERS SURETY Et INDEM CO 275167C 07/31/2010 Until Cancelled $12,000.00 08/02/2010 8 WESTERN SURETY CO 158734001 06/16/2006 Until Cancelled 07/31/2010 $12,000.0006/22 /2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 25 American Fire Et Casualty Co BKA55005445 02/01/2011 02/01/2013 $1,000,000.00 01/30/2012 24 AMERICAN FIRE AND CAS CO BLA53308770 02/01/2011 02/01/2012 $1,000,000.00 01/05/2011 23 AMERICAN FIRE AND CAS CO BKA53308770 02/01/2008 02/01/2011 $1,000,000.0001 /27/2010 22 AMERICAN FIRE Et CAS BKW53308770 02/01/2007 02/01/2008 $1,000,000.0001 /30/2007 21 AMERICAN FIRE Et CASUALTY CO BKA533398770 02/01/2006 02/01/2007 $1,000,000.00 03/10/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 01/11/2013 GENERAL NOTES PROJECT TEAM cntury in REAL ESTATE TUKWILA CYBER - INTERIOR UPGRADES 6101 SOUTH 180TH. STREET TUKWILA, WA. 98188 AREA OF WORK. ALL WORK OF THE GENERAL CONTRACTOR AND HIS SUBCONTRACTORS (HEREIN REFERRED COLLECTIVELY AS THE CONTRACTOR) SHALL CONFORM TO THE PROVISIONS OF THE FEDERAL, STATE, CITY, AND COUNTY BUILDING LAWS, ORDINANCES, RULES AND REGULATIONS. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND LICENSES AND GIVE ALL NECESSARY NOTICES. THE OWNER SHALL PAY COSTS OF ALL INCIDENTAL FEES - INCLUDING THE CERTIFICATE OF OCCUPANCY. THE CONTRACTOR SHALL MAINTAIN ADEQUATE PROTECTION OF ALL HIS WORK FROM DAMAGE, AND SHALL PROTECT THE OWNER'S PROPERTY, ADJACENT PROPERTY, AND PUBLIC PROPERTY FROM DAMAGE AND INJURY ARISING IN CONNECTION WITH THIS CONTRACT, AND SHALL MAKE GOOD ANY SUCH DAMAGE OR INJURY AT NO COST TO THE OWNER. OWNER: CENTURYLINK REAL ESTATE 8534 CONCORD CENTER DRIVE ENGLEWOOD, CO. 80112 CONTACT: DAN GLEASON PH: 303.992.4993 e -mail: Dan.Gleason @CenturyLink.com THE CONTRACTOR SHALL WARRANT AND GUARANTEE ALL MATERIALS AND WORKMANSHIP, FOR ALL PORTIONS OF THE WORK, FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL COMPLETION AND ACCEPTANCE BY THE OWNER, AND SHALL REPAIR OR REPLACE ALL WORK THAT BECOMES DEFECTIVE, AT NO ADDITIONAL EXPENSE. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE BEST SKILL AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCE AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. UNLESS NOTED OTHERWISE, THE CONTRACTOR SHALL PROVIDE AND PAY FOR ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT AND MACHINERY, TRANSPORTATION, AND OTHER FACILITIES AND SERVICES NECESSARY FOR PROPER EXECUTION AND COMPLETION OF WORK. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, CLEARANCES AND FIELD CONDITIONS. REPORT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. ALL PENETRATIONS THROUGH WALLS AND FLOORS SHALL BE SEALED WITH FIRE STOPPING MATERIAL AS REQUIRED TO ACHIEVE THE RESPECTIVE FIRE - RESISTIVE RATING AND SMOKE STOPPAGE, AS REQUIRED BY LOCAL BUILDING CODES. THE CONTRACTOR SHALL COORDINATE AND VERIFY ALL MECHANICAL, ELECTRICAL AND PLUMBING PORTIONS OF THE WORK, AND THE LOCATIONS OF ALL PIPING, DUCTWORK, TRENCHES, SLEEVES, SPECIAL BOLTING FOR EQUIPMENT, CONDUITS, ETC., THROUGH AND UNDER CONCRETE SLABS PRIOR TO POURING OF FOOTINGS AND FLOOR SLABS. THE CONTRACTOR SHALL VERIFY UTILITY LOCATIONS. 10.. THE CONTRACTOR, AND ALL OTHERS PROVIDING WORK OR MATERIALS SHALL PROVIDE AND MAINTAIN COMPLETE WORKMAN'S COMPENSATION AND OTHER NECESSARY INSURANCE (EXCEPT "ALL RISK" INSURANCE). PROVIDE CERTIFICATES PRIOR TO COMMENCING WORK. ARCHITECT: MICHAEL BAKER JR. INC. 2929 N. CENTRAL AVENUE SUITE 800 PHOENIX, AZ. 85012 CONTACT: MATT LAMONT, RA, NCARB OPERATIONS DIRECTOR PH: 602.798.7546 FAX: 602.279.1411 e -mail: Matthew .Lamont @mbakercorp.com. CONTACT: BRUCE PRESTON PROJECT MANAGER PH: 602.798.7515 e -mail: bpreston @mbakercorp.com' MECH., ELECT. & PLUMING: CEC - COMMUNICATIONS ENGINEERING CONSULTANTS 6820 LAUFFER ROAD COLUMBUS, OHIO 43231 CONTACT: MICHAEL LOY PH: 614.3922907 e -mail: michael.loy @ceclimited.com SECURITY: STANLEY SECURITY SOLUTIONS 7399 SOUTH TUCSON WAY SUITE A -6 CENTENNIAL, COLORADO 80112 CONTACT: ED MCMURRER ACCESS CONTROL AND SURVEILLANCE SYSTEM CONTRACTOR PH: 303.232.5600 MOBILE: e -mail: Ed.Mcmurrer @sbdinc.com 11. THE CONTRACTOR SHALL KEEP THE PROJECT WORK IN A CLEAN AND ORDERLY FASHION AT ALL TIMES DURING CONSTRUCTION. UPON COMPLETION OF EACH STAGE (OR DAILY), LEAVE ALL WORK AREAS AND FINISHED SPACES "BROOM CLEAN" AND IN ACCEPTABLE CONDITION. 12. ` THE DESIGN ADEQUACY AND SAFETY OF ERECTION, BRACING, SHORING, TEMPORARY SUPPORT, ETC., ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 13. THE CONTRACTOR'S PRICES SHALL INCLUDE ALL LOCAL TAXES, DELIVERY AND INSTALLATION COST. 14. THE USE OF BRAND TRADE NAMES IN DESCRIBING MATERIALS OR PRODUCTS IS INTENDED TO SET MINIMUM STANDARDS FOR THOSE ITEMS; HOWEVER, ANY SUBSTITUTION MUST BE APPROVED BY MICHAEL BAKER JR. INC. IN WRITING BEFORE BEING USED IN THE WORK. 15. DIMENSIONS NOTED AS "CLEAR" SHALL BE FROM FINISHED MATERIAL FACE. ALL DIMENSIONS TO STUD WALLS ARE TO FACE OF STUD. ALL DIMENSIONS TO MASONRY OR CONCRETE WALLS ARE TO FACE OF MASONRY OR CONCRETE. DIMENSIONS TO STRUCTURAL MEMBERS SUCH AS BEAMS AND OR COLUMNS ARE TO CENTERLINE OF STRUCTURAL MEMBER. 16. GENERAL CONTRACTOR IS RESPONSIBLE TO MAINTAIN A CURRENT SET OF DRAWINGS ON SITE AT ALL TIMES AND TO ENSURE THE DISTRIBUTION OF NEW DRAWINGS TO SUB - CONTRACTORS AND OTHER RELEVANT PARTIES AS SOON AS THEY ARE MADE AVAILABLE. 17. RECORD DOCUMENTS: UPON COMPLETION OF THE PROJECT, CONTRACTOR SHALL PROVIDE OWNER AND TENANT WITH A COMPLETE SET OF RECORD DOCUMENTS INCLUDING RECORD DRAW@r!GS, A LIST OF SUBCONTRACTORS USED ON THE PROJECT, MANUFACTURER'S WARRANTIES, OPERATioN.AND MAINTENANCE MANUALS FOR MAJOR PIECES OF EQUIPMENT, AND INSTRUCTION MANUALS WHEN APPROPRIATE FOR BUILDING SYSTEMS. 18. DIMENSIONS INDICATED IN CONTRACT DOCUMENTS SHALL GOVERN. DO NOT SCALE DRAWINGS. 19. PROVIDE 2A -10B :C FIRE EXTINGUISHERS WITH TRAVEL DISTANCE NOT TO EXCEED 75' IN ACCORDANCE WITH NFPA STANDARDS, AS DIRECTED BY THE FIRE MARSHAL. 20. THE USE OF THE WORD "PROVIDE" IN CONNECTION WITH ANY ITEM SPECIFIED IS INTENDED TO MEAN THAT SUCH SHALL BE FURNISHED, INSTALLED, AND CONNECTED, WHERE SO REQUIRED. NOTICE OF EXTENDED CERTIFICATION AND APPROVAL PERIOD PROVISION THIS CONTRACT ALLOWS THE OWNER TO CERTIFY AND APPROVE BILLINGS ESTIMATES WITHIN 30 DAYS AFTER THE BILLINGS AND ESTIMATES ARE RECEIVED FROM THE CONTRACTOR. NOTICE OF EXTENDED PAYMENT PROVISION THIS CONTRACT ALLOWS THE OWNER TO MAKE PAYMENT WITHIN 45 DAYS AFTER CERTIFICATION AND APPROVAL OF BILLINGS AND ESTIMATES. SHEET INDEX GENERAL G -101 COVER SHEET G -102 EXIT ANALYSIS PLAN ARCHITECTURAL SEPARATE PERMIT REQUIRED FOR ❑ Mechanical " Eectrica) umbing A -001 ABBREVIATIONS & GENERAL NOTES A -101 DEMOLITION FLOOR & RCP PLANS A -102 NEW FLOOR & RCP PLANS A -103 • ENLARGED FINISH FLOOR PLAN A -501 PARTITION TYPES & DETAILS A -502 ARCHITECTURAL DETAILS A -601 SCHEDULES & DETAILS MECHANICAL City of Tukwila B ALDI!;CI DIVISION M -001 ABBREVIATIONS & GENERAL NOTES M -101 DEMOLITION MECHANICAL & F P PLANS M -102 MECHANICAL & FP PLANS ELECTRICAL E -001 ABBREVIATIONS & GENERAL NOTES E -101 DEMOLITION FLOOR & RCP PLANS E -102 NEW FLOOR & RCP PLANS REVISIONS No changes shall be a to the scope of work without prior approval of Tukwila Building Division. 1' C T Z: Revisions rs will require a new plan submittal and may inc udd additional plan review fees. FILE COPY Permit No. Phi r fievi approval is subject to errors and omiSSicns, of construction documents does not .uthct.1 of ariy adopted code or ordinance. Rcpt . o L ,roved Held Copy and conditions is acknowledged. VICINITY MAP SCALE: N.T.S. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 042012 City of Tukwila BUILDING DIVISION RECEIVED CITY. OF TUKWILA NOV 2 6 2012 PERMIT CENTER LIII 1 . . IIII It L ....I ti�l CONSULTANT FIRM GEO LOC ID FLOOR s1, CenturyLink FIRST BUILDING N I UKWILA CYBER - INTERIOR UPGRADES STREET ADDRESS CITY, STATE 6101 SOUTH 180TH. STREET TUKWILA, WA. 98188 DESCRIPTION MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 STAMP TITLE SHEET CONSULTANT NAME REVISIONS NOTICE The Information contained herein should not be disclosed to unauthorized persons. It is meant for use by authorized representatives of CenturyUnk KEY PLAN SCALE: 1" = 80' -0" LOCATION MAP SCALE: N.T.S. No. DESCRIPTION DATE. DRAWN BY AP DATE 10/04/12 CHECKED BY BP REVISED BY SCALE FILE NAME SHEET NO. BP /AP N.T.S. G -10 O g o_ J 0 z cC m c: 3 CV N 0 r.: 0 Y 0 t J w z 0 to U z J W F-' U cc O - ' LL 61 a) D • '. o: 0- 0 EXTERIOR ELEVATION WITH SHEET NUMBER PARTIAL ELEVATION WITH SHEET NUMBER INTERIOR ELEVATION WITH SHEET NUMBER DETAIL WITH SHEET NUMBER SECTION WITH SHEET NUMBER DOOR NUMBER AREA OF WORK Eta CEILING HEIGHT ABOVE FINISHED FLOOR (A.F.F.) DATUM ELEVATION WALL TYPES EXIT ANALYSIS PLAN SCALE: 1" = 30' -0" CODE INFORMATION TOTAL FLOOR AREA: NO CHANGE. REMAIN EXISTING BUILDING CODES OBSERVED: 2009 IBC 2009 IMC 2009 IFC CONSTRUCTION TYPE (PER IBC):, TYPE: II -B OCCUPANCY TYPE: B RECEIVED CITY OF TUKWILA NOV 2 6 2012 PERMIT CENTER CONSULTANT FIRM ';'11F44 CenturyLink GEO LOC ID - FLOOR FIRST BUILDING III. CYBER - INTERIOR UPGRADES STREET ADDRESS 6101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 DESCRIPTION MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 EXIT ANALYSIS PLAN CONSULTANT NAME No. REVISIONS DESCRIPTION NOTICE The information contained herein should not be disclosed to unauthorized persons. It is meant for use by authorized representatives of CenturyLlnk. DATE DRAWN BY AP DATE 10/04/12 CHECKED BY BP SHEET NO. _ REVISED BY BP /AP SCALE 1"=30'-0" G -102 0) 0 5 0 J 0 Z iii m E m ic. O (0 O' 0 P c� co m 0 C7 J cn CO Z tL a) d CI c co 0 N 0 O c 'C 0 L •o Q to ) E.) a� c 0 U 2 0 0 0 0 2 a 2 0 0 o U N rn o c N 2 N c �c t0 c co ■ AO VAV DISCHARGE DUCTWORK SADDLE TAP SYMBOL MECHANICAL DESCRIPTION —CWR— —CWS— —HWR- —HWS— T O EXISTING WORK TO REMAIN EXISTING WORK TO BE REMOVED NEW WORK RISE OR DROP PIPE BRANCH : TOP CONNECTION PIPE BRANCH BOTTOM CONNECTION CHILLED WATER RETURN CHILLED WATER SUPPLY HOT WATER RETURN HOT WATER SUPPLY CONCENTRIC REDUCER THERMOSTAT TEMPERATURE SENSOR 0 CONNECT TO EXISTING SUPPLY DUCT UP R.A., O.A., OR EXH, DUCT, UP ROUND DUCT FLAT OVAL DUCT SPIN -IN FITTING WITH EXTRACTOR AND BALANCE DAMPER ELBOW WITH TURNING VANES FIRE . DAMPER MAN. DAMPER SPRINKLER HEAD FLEX DUCT DEFINITIONS "INDICATED ": REQUIREMENTS EXPRESSED BY GRAPHIC REPRESENTATIONS OR IN WRITTEN FORM ON DRAWINGS, IN SPECIFICATIONS, AND IN OTHER CONTRACT DOCUMENTS. OTHER TERMS INCLUDING "SHOWN," "NOTED." "SCHEDULED," AND "SPECIFIED" HAVE THE SAME MEANING AS INDICATED. "FURNISH ": SUPPLY AND DELIVER TO PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS. "INSTALL ": OPERATIONS AT PROJECT SITE INCLUDING UNLOADING, TEMPORARILY STORING, UNPACKING, ASSEMBLING, ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS. "PROVIDE ": FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE. SEAL JOINTS WITH DUCT MASTIC (TYP.) • • TAP INTO EXISTING VAV DISCHARGE DUCT MANUAL BALANCING DAMPER INSULATED FLEXIBLE DUCT ∎�� HARD ROUND DUCT DUCT INSULATION SECURE FLEX DUCT TO ELBOW AND DIFFUSER WITH r . GALVANIZED ADJUSTABLE BAND CLAMPS WITH CADMIUM PLATED BUCKLE AND SCREWS WITH SLOTTED HEX HEAD. PLACE BAND CLAMPS BETWEEN THE WIRES OF LAST SPIRAL OF THE FLEX DUCT. SECURE FLEX DUCT TO SPIN -IN COLLAR AND AIR DEVICE COLLAR WITH SHEET METAL SCREWS. MAXIMUM LENGTH OF FLEX DUCT IS 7'. EXISTING SQUARE CEILING DIFFUSER REINSTALLED BY MECHANICAL CONTRACTOR NOTE SEE PLANS FOR ACTUAL DUCT SIZES. 24"X24" CEILING GRID n CEILING DIFFUSER CONNECTION M -001 N. T. S. MECHANICAL ABBREVIATIONS. AB. A.D. A.F.F. APPROX. ATC AUTO. CONT. BTM. BLDG. BAS CAB. CAP. C.B. C.I. CLG. CH CONC. C.O. CONN. CONTR. CONT. CONV. COORD. CRAC DTL DIA. DIFF. DISCH. DN. D.S. EC ELEC. E.W.C. ELEM. ELEV. EXH EXIST. FT. HD. FIN. RAD. F. DPR. F. E. F.E.C. F.H.C. FLEX. F & T FLR. F.D. FURN. GA. GEN. GRAV. ABOVE ACCESS DOOR ABOVE FINISHED FLOOR APPROXIMATELY AUTOMATIC TEMPERATURE CONTROL AUTOMATIC CONTROL BOTTOM BUILDING BUILDING AUTOMATION SYSTEM CABINET CAPACITY CATCH BASIN CAST IRON CEILING CEILING HEATER CONCRETE CLEAN OUT CONNECT CONTRACTOR CONTINUATION CONVECTOR COORDINATE COMPUTER ROOM AIR CONDITIONER DETAIL DIAMETER DIFFUSER DISCHARGE DOWN DOWNSPOUT ELECTRICAL CONTRACTOR ELECTRICAL ELECTRIC WATER COOLER ELEMENT ELEVATION EXHAUST. EXISTING FEET OF HEAD FINNED RADIATION FIRE DAMPER FIRE EXTINGULSHER FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FLEXIBLE FLOAT & THERMOSTATIC FLOOR FLOOR DRAIN FURNISH GAGE GENERAL GRAVITY GR. H.B. HTR. HTG. H & A/C INV. ELEV. J. R. LAV. MAN. DPR. M. H. MFR. MECH. MC MOP M. A. MID. NOM. OPNG. O.A. PLBG. PRESS. P.R.V. PROP. REG. RHC. REQD. REL. R.A. R.D. RM. SCHED. S.D. SHT.MTL. SH. S.I. S.S. STAT. S.A. S & R TEMP. THERM. TYP. T.C.C. UR. V.S.P. VIB. ISOL V.T.R. W. W/ W.C. GRILLE HOSE BIBB HEATER HEATING HEATING & AIR CONDITIONING INVERT ELEVATION . JANITOR RECEPTOR LAVATORY. MANUAL DAMPER MANHOLE MANUFACTURER, MECHANICAL MECHANICAL CONTRACTOR METHOD OF PROCEDURE MIXED AIR MOUNTED NOMINAL OPENING OUTSIDE AIR PLUMBING PRESSURE PRESSURE REDUCING VALVE PROPELLER REGISTER REHEAT COIL REQUIRED RELIEF RETURN AIR ROOF DRAIN ROOM SCHEDULE SHOWER DRAIN SHEET METAL SHOWER SURFACE INLET SERVICE SINK THERMOSTAT SUPPLY AIR SUPPLY & RETURN TEMPERATURE THERMOMETER TYPICAL TEMP. CONTROL CONTRACTOR URINAL VITRIFIED SEWER PIPE . VIBRATION ISOLATOR VENT THRU ROOF WASTE WITH WATER CLOSET VAV DISCHARGE AIR DUCT FROM VAV 193 FIRE PROTECTION NOTES 1. ALL FIRE PROTECTION CONTRACT WORK IS TO COMPLY WITH THE APPLICABLE NFPA STANDARDS REFERENCED IN THE BUILDING CODE (OBC) AS ADMINISTERED BY THE LOCAL REVIEW /INSPECTION /APPROVAL AUTHORITIES, THE INSURANCE UNDERWRITER'S GUIDELINES, THE LOCAL FIRE PREVENTION AUTHORITY (FIRE MARSHALL'S OFFICE /FIRE DEPARTMENT), AND ANY OTHER AUTHORITIES HAVING JURISDICTION, AS CONFIRMED AND VERIFIED IN ADVANCE BY THE LICENSED FIRE PROTECTION CONTRACTOR. 2 COORDINATE THE REMOVAL AND ADDITION OF PIPING AND SPRINKLER HEADS WITH THE MECHANICAL AND ELECTRICAL CONTRACTOR. 3 INSTALL NEW SPRINKLER HEADS WHERE ADDITIONAL HEADS ARE NEEDED TO MAINTAIN COVERAGE AND WHERE EXISTING HEADS ARE TO BE RELOCATED. THE REUSE OF EXISTING SPRINKLER HEADS ARE ONLY PERMITTED WHERE EXISTING SPRINKLER HEADS ARE TO REMAIN. FIRE PROTECTION CONTRACTOR. SHALL FIELD VERIFY AND SECURE ALL MEASUREMENTS AND CONDITIONS BEFORE PROCEEDING WITH NEW INSTALLATION AND ANY MODIFICATIONS TO EXISTING SYSTEM. THE SPRINKLER SYSTEM SHALL BE HYDRAULICALLY DESIGNED AND SIZED ACCORDING TO NFPA PAMPHLET NO. 13, THE APPLICATION BUILDING CODE AND THE INSURER'S GUIDELINES, RULES AND REGULATIONS (REQUIRED FOR APPROVAL). ALL SPRINKLER PIPING AND FITTINGS SHALL BE SCHEDULE 40, SEAMLESS, GALVANIZED WITH THREADED FITTINGS. ALL EXISTING SPRINKLER HEADS TO REMAIN ARE TO BE FIELD VERIFIED BY THE FIRE PROTECTION CONTRACTOR IN ADVANCE. COORDINATE ALL NEW SPRINKLER DROPS FOR HEAD LOCATIONS WITH EXISTING AND NEW DUCTWORK, PIPING, AND EQUIPMENT. FPC SHALL SUBMIT SHOP DRAWINGS INDICATING NEW SPRINKLER HEAD LOCATIONS, TO THE ARCHITECT FOR REVIEW AND APPROVAL. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR FIRESTOPPING AT ALL FIRE PROTECTION RELATED PENETRATIONS OF FIRE AND SMOKE RATED WALLS AND PARTITIONS. REFER TO ARCHITECTURAL FLOOR PLANS FOR LOCATIONS OF ALL RATED STRUCTURES. 9. RUN ALL PIPING IN FINISHED AREAS CONCEALED WHEREVER POSSIBLE. 10. ALL PIPING SHOWN IS ABOVE CEILING IN AREAS WITH DROPPED CEILINGS. 11. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR REVIEWING ARCHITECTURAL PROJECT DOCUMENTATION FOR ITEMS AFFECTING FIRE PROTECTION WORK, INCLUDING SPECIFIC DIRECTIONS AND ITEMS OF A GENERAL NATURE, WHICH MAY NOT BE REFERRED TO BY THE FIRE PROTECTION DOCUMENTATION. THIS MAY INCLUDE, BUT IS NOT LIMITED TO, SPRINKLER REQUIREMENTS TO MAINTAIN RATED SEPARATION STRUCTURES (WALLS, WINDOWS, GLASS PARTITIONS /DOORS, ETC.), OR AT PROTECTION FEATURES SUCH AS DRAFTSTOPS AND OTHER STRUCTURAL ELEMENTS. WHERE THERE IS A DISCREPANCY IN LOCATIONS INDICATED BETWEEN THE TWO SETS OF DOCUMENTATION, THE LOCATION INDICATED BY THE ARCHITECTURAL SHALL TAKE PRECEDENT. ARCHITECTURAL REVIEW SHALL INCLUDE COMPLETE DOCUMENTATION, INCLUDING SPECIFICATIONS AND DRAWING ELEVATIONS. 12. FIRE PROTECTION CONTRACTOR SHALL CAP PIPING AND CLOSE VALVES WHERE NECESSARY AND RETURN THE LOCAL SYSTEM TO ACTIVE DUTY AT THE END OF EACH WORK DAY. 13. A COMPLETED CONTRACTORS MATERIAL AND TEST CERTIFICATE SHALL BE PROVIDED UPON COMPLETION OF THE PROJECT. 14. PROVIDE ESCUTCHEON COVER PLATES FOR ALL NEW SPRINKLER HEADS.; 15. IN AREAS WHERE CEILING GRID IS INSTALLED, FIRE PROTECTION CONTRACTOR SHALL PROVIDE AND INSTALL SPRINKLER HEADS TO MATCH EXISTING HEADS IN AREA. 16. FIRE PROTECTION CONTRACTOR SHALL AT NO TIME INSTALL HEADS IN SOFFIT. RELOCATE OR PROVIDE NEW IN CEILING AREA ONLY 17. UNLESS DIRECTED OTHERWISE, WHERE EXISTING STRUCTURE IS BEING REMOVED /REMODELED OR OTHERWISE REVISED, THE FIRE PROTECTION CONTRACTOR SHALL REVISE THE EXISTING SPRINKLER INSTALLATION AND PROVIDE NEW FIRE PROTECTION ITEMS /ELEMENTS AS REQUIRED TO PROVIDE /MAINTAIN. THE COVERAGE SPECIFIED HEREIN. THIS INCLUDES SPACING AND LOCATION REQUIREMENTS (MINIMUM /MAXIMUM) BETWEEN SPRINKLER HEADS /PIPING AND RELATIVE TO WALLS, SOFFITS, PARTITIONS AND ANY OTHER OBSTRUCTIONS TO SPRINKLER DISCHARGE. IN AREAS WHERE EXISTING WALLS ARE REMOVED, MODIFY EXISTING AND PROVIDE NEW SPRINKLER HEADS TO ALIGN WITH EXISTING GRID PATTERN. ROUND AIR DUCT TO 315 CFM DIFFUSER NOTE SEE PLANS FOR ACTUAL DUCT SIZES. • CONICAL SADDLE TAP CONNECTED INTO VAV DISCHARGE AIR DUCT FROM VAV 193 e DUCTWORK CONNECTION DETAIL M -001 N. T. S GENERAL NOTES. THE CONTRACTOR SHALL OBSERVE ALL FIRE AND LIFE SAFETY RULES, INCLUDING THE USE OF APPROVED AND CERTIFIED FIRE EXTINGUISHERS, PLACEMENT OF FIRE BLANKETS, THE USE OF INDEPENDENT FIRE WATCH PERSONNEL, CONTAINMENT, AND THE PROPER NOTIFICATION OF THE OWNER REPRESENTATIVE PRIOR TO THE START OF. WORK. WHEN WORKING IN THE BUILDING THE CONTRACTOR SHALL NOTIFY THE OWNER AND REQUEST THAT THE FIRE ALARM SYSTEM BE PUT INTO THE TEST OR BYPASS MODE. . THE CONTRACTOR SHALL CONFIRM WITH THE OWNER THAT THE PROPER FIRE ALARM MONITORING AUTHORITIES HAVE BEEN NOTIFIED. PERFORM NO WORK UNTIL VERIFICATION OF THIS PROCEDURE IS COMPLETE. THERE WILL BE NO UNSCHEDULED SHUTDOWNS OF THE OWNERS SERVICES OR OF. THE SERVICES EXTENDED FOR OWNERS CUSTOMERS. ALL WORK SHALL BE SUPERVISED BY A DIRECT EMPLOYEE OF THE CONTRACTOR, AUTHORIZED TO SUPERVISE THE WORK, IMPLEMENT THE NECESSARY PROTECTION. MEASURES, CURTAIL UNSAFE OR IMPROPER WORK PROCEDURES, AND FULLY INFORMED OF THE NATURE OF THE FACILITY AND THE SPECIAL PRECAUTIONS REQUIRED TO PERFORM WORK IN THE BUILDING. THE CONTRACTOR SHALL PROVIDE THE OWNER'S REPRESENTATIVE WITH A COMPLETE LIST OF EMPLOYEES WHO • WILL BE IN THE FACILITY, AND A LIST OF THE SUBCONTRACTORS (AND THEIR EMPLOYEES) PRIOR TO THE START OF WORK. ALL WORK SHALL BE PERFORMED BY DIRECT EMPLOYEES OF THE CONTRACTOR, OR BY DIRECT EMPLOYEES OF THE APPROVED SUBCONTRACTOR. THE OWNER RESERVES THE RIGHT TO PROHIBIT ANY EMPLOYEE OR SUBCONTRACTOR FROM WORKING ON SITE. THE OWNER HAS THE 'RIGHT TO REFUSE ACCESS TO THE FACILITY IF IN HIS OPINION THE EMPLOYEE OR SUBCONTRACTOR POSES A RISK TO THE OWNERS SERVICES. 7. THE OWNER MAINTAINS A COMPREHENSIVE CONSTRUCTION GUIDELINE MANUAL THAT ADDRESSES ALL WORK RULES IN ON OR AROUND THE FACILITY. ON A DAILY BASIS, PRIOR TO ENTERING THE WORK AREA, THE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR AND INDICATE THE NATURE. OF THE WORK AND THE AREA IN WHICH THE WORK WILL BE PERFORMED. COORDINATE THE INSTALLATION AND USAGE OF PROTECTIVE BARRIERS WITH GENERAL CONTRACTOR. 10. COORDINATE THE REMOVAL AND RELOCATION OF HVAC . ITEMS WITH ALL CONTRACTORS. 11. 12. MECHANICAL CONTRACTOR SHALL COORDINATE THE DISPOSAL OF ALL REMOVED EQUIPMENT, MATERIALS, AND DEVICES WITH OWNER. MAINTAIN A CLEAN AND ORGANIZED WORK AREA AND WHEN TERMINATING THE WORK AT THE END OF THE DAY. • REINSTALL ALL CEILING TILES, COVER ALL OPENINGS, SWEEP AND REMOVE ALL DEBRIS, STORE ALL TOOLS AND MATERIALS IN APPROVED LOCATIONS, SET AND SECURE ALL SAFETY BARRIERS AS APPROPRIATE. 13. ALL WORK TO BE REMOVED AND INSTALLED PER ALL FEDERAL, STATE, AND LOCAL CODES. 14. REFER TO ARCHITECTURAL PLANS. FOR EXISTING AND NEW REFLECTED CEILING PLANS AND DETAILS. 15. ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR INVOLVED. 1 ALL EQUIPMENT SHOWN ON THIS SHEET IS EXISTING TO REMAIN UNLESS NOTED OTHERWISE. 17. THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL EXISTING CONDITIONS PRIOR' TO START OF WORK, IF ANY DISCREPANCIES ARE FOUND, NOTIFY THE ENGINEER IN WRITING. 18.` MECHANICAL CONTRACTOR RESPONSIBLE FOR REPAIR OF ANY DAMAGE TO CEILING TILES AND /OR CEILING GRID DUE TO REMOVAL AND RELOCATION OF THE HVAC ITEMS AND EQUIPMENT. 19. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING, CUTTING,' AND RELOCATING ALL ITEMS AS CALLED OUT ON PLANS. COORDINATE WORK WITH ALL OTHER DISCIPLINES. 20. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL SYSTEM DOWN TIME AFTER HOURS, WITH OWNER, TO PERFORM ALL MODIFICATIONS NECESSARY AS PER THE SCOPE OF WORK CALLED OUT ON PLANS., 21. MECHANICAL CONTRACTOR SHALL FIELD VERIFY AND PERFORM ALL WORK NECESSARY TO ENSURE ALL CEILING MOUNTED HVAC ITEMS IN NEW CEILING GRID ARE PROPERLY INSTALLED IN CEILING TILES. 22. MECHANICAL CONTRACTOR SHALL PROVIDE AN AIR FLOW TEST REPORT OF EACH DIFFUSER SCHEDULED TO BE RELOCATED. UPON COMPLETION OF RELOCATION WORK, MECHANICAL CONTRACTOR SHALL RE- BALANCE AIR DEVICES TO ORIGINAL VALUES. 23. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR RE- BALANCING THE EXISTING AND NEW VAV TERMINALS IF APPLICABLE. PROVIDE AIR BALANCE REPORT TO ENGINEER AT COMPLETION OF PROJECT. 24. MECHANICAL CONTRACTOR SHALL NOTIFY PROJECT MANAGER AT THE COMPLETION OF THE DEMOLITION PHASE AND PRIOR TO ANY RELOCATION OR NEW WORK PERFORMED. i REVIEWED FOR ,ODE COMPLIANCE APPROVED DEC 0 4 2012 RECEIVED CITY OF TUKWILA NOV 2 6 2012 PERMIT CENTER MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 CONSULTANT FIRM MECHANICAL/ELECTRICAL ENGINEERING COMMUNICATIONS ENGINEERING CONSULTANTS PHOENIX AZ COLUMBUS, OH 2575 CAMELBACK ROAD 8820 LAUFFER ROAD PHOENIX ARIZONA 88018 ( COLUMBUS, OHIO 43231 P:802.343.7414 P914.392.2902 F:801343.2301 F:814.3922907 wwx.ceclMtedcom %Lip Centu rY Link GEO LOC ID FLOOR BUILDiC� ffFj(vl I CYBER - INTERIOR UPGRADES STREET �AJD�D(RwES 6101 SOUTH 180TH. STREET TUKWILA, WA. 98188 CITY, STATE DESCRIPTION ABBREVIATIONS & GENERAL NOTES STAMP ISSUED FOR CONSULTANT NAME BID SET REVISIONS NOTICE The Information contained herein should not be disclosed to unauthorized persons. It Is meant for use by authorized representatives of CenturyUnk: No. DESCRIPTION DATE DRAWN BY DATE CHECKED BY JAG 10/04/12 NMO CASE NUMBER JOB NO. 12033 REVISED BY SCALE N.T.S. FILE NAME SHEET NO. 00 1 MEN'S RESTROOM JANITOR'S CLOSET MECHANICAL CONTRACTOR SHALL REMOVE EXISTING SUPPLY AIR DEVICE FROM CEILING GRID AND DISCONNECT FROM DUCT. STORAGE OF THE AIR DEVICE SHALL BE COORDINATED WITH OWNER AND THE DEVICE SHALL BE CLEANED BEFORE BEING REINSTALLED. EXISTING DUCTWORK SHALL BE REMOVED AS NECESSARY AND MODIFIED FOR REUSE WHERE POSSIBLE. MECHANICAL CONTRACTOR SHALL REMOVE SECTION OF EXISTING EXHAUST DUCT NECESSARY FOR . INSTALLING NEW EXHAUST DUCTWORK. FIRE PROTECTION CONTRACTOR SHALL REMOVE EXISTING SPRINKLER HEAD AND ASSOCIATED RUN OUT. 315 CFM DIFFUSER EXISTING WORK TO REMAIN — . EXISTING WORK TO BE REMOVED 315 CFM DIFFUSER SECURITY LOBBY 315 CFM DIFFUSER VAV 19 VAV 193 HALLWAY 2 STORAGE VAV 192 EQUIPMENT ROOM CONFERENCE: ROOM VAV 203 DEMOLITION HVAC PLAN SCALE: 1/4" = 1' -0 AREA OF WORK BREAK ROOM —.- -T4Etw 7 1 H,QLLWAY 2 RECEIVED CITY OF TUKWILA S AGE CONSULTANT FIRM FLOOR MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800 PHOENIX, ARIZONA 85012 (602) 279 -1234 MECHANICALJELECTRICAL. -. ENGINEERING BUILDIMME — INTERIOR UPGRADES STREETADDRES 61101 SOUTH 180TH.' STREET CITY, STATE TUKWILA, WA. 98188 COMMUNICATIONS ENGINEERING CONSULTANTS PHOENIX, AZ COLUMBUS, OH 2878 CAMELBACK ROAD 88201AUFFER ROAD PHOENIX ARIZONA 85018 COLUMBUS, OHIO43231 P1802.343.7414 P:814.3B2.2802 F:602.3432301 F:814.3922907 ISSUED FOR V) c co BID SET REVISIONS No. DESCRIPTION NOTICE The Information contained herein should not be disclosed to unauthorized persons. It Is meant for use by authorized representatives of CenturyLlnk. CASE NUMBER DEMOLITION FIRE PROTECTION PLAN SCALE: 1/4" = 1' -0" DATE 12033 CHECKED BY FILE NAME SHEET NO. SCALE MEN'S RESTROOM JANITOR'S CLOSET �M -001 CEILING DIFFUSER CONNECTION 101 315 CFM- DIFFUSER BYPASS 102 10 "0 VAV DISCHARGE DUCT 103 135 CFM DIFFUSER M -001 MECHANICAL_ CONTRACTOR SHALL INSTALL PREVIOUSLY REMOVED AND CLEANED SUPPLY AIR DEVICE. SUPPLY AIR DEVICE TO BE CONNECTED TO VAV DISCHARGE DUCT ` WITH PREVIOUSLY REMOVED CONNECTIONS AND DUCTWORK IF POSSIBLE. PROVIDE NEW 10 "0 SUPPLY DUCTWORK, SADDLE TAP, AND CONNECTION COMPONENTS WHERE NECESSARY TO MAKE CONNECTION. MECHANICAL CONTRACTOR SHALL PROVIDE NEW 24 "X12" RETURN AIR DEVICE. MATCH EXISTING COLOR AND MODEL. MECHANICAL CONTRACTOR SHALL PROVIDE NEW TAP ` IN EXISTING VAV DISCHARGE DUCTWORK, SEAL ALL. EDGES AND JOINTS WITH DUCT MASTIC. REPAIR INSULATION WHERE NECESSARY. MECHANICAL. CONTRACTOR SHALL COORDINATE DUCTWORK LOCATION WITH GENERAL CONTRACTOR AT INTERSECTION OF DUCTWORK AND NEW FULL HEIGHT WALL. PRIOR TO ANY GENERAL CONSTRUCTION WORK. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR. CONSTRUCTING WALL AROUND DUCTWORK CREATING A DUCTWORK PENETRATION WHERE NECESSARY. MECHANICAL CONTRACTOR SHALL PROVIDE FIRE CAULKING AROUND ANY DUCTWORK. PENETRATING A FIRE RATED WALL. MECHANICAL CONTRACTOR SHALL PROVIDE NEW EXHAUST DUCTWORK TO CONNECT TO EXISTING EXHAUST DUCTWORK. CONTRACTOR SHALL REUSE EXISTING DUCT SUPPORTS AND HANGERS WHERE, POSSIBLE. MECHANICAL CONTRACTOR SHALL CAP VAV DISCHARGE DUCT WITH SHEET METAL CAP. ALL. JOINTS AND EDGES TO BE SEALED WITH DUCT MASTIC. CAP TO BE INSULATED. FIRE PROTECTION CONTRACTOR SHALL PROVIDE NEW TAP, RUN OUT, ESCUTCHEON, AND SPRINKLER HEAD TO MATCH EXISTING. FIRE PROTECTION CONTRACTOR SHALL PROVIDE ALL NECESSARY SPRINKLER PIPING AND SPRINKLER HEADS TO PROVIDE ADEQUATE COVERAGE IN COMPLIANCE WITH NFPA CODES AND REGULATIONS. HALLWAY 1 10 "41 VAV DISCHARGE D CT VAV 199 HALLWAY 2 CEILING DIFFUSER CONNECTION M -001 STORAGE VAV 192 EQUIPMENT ROOM 105 JANITOR'S CLOSET S.0.C. z .1r :fl' BYPASS HEAR ROOM fCURITThr LOBBY 104 crzrxcI H LLWAY 1 KEY PLAN SCALE: N.T.S. HALLWAY TO RAG RECEIVED CITY OF TUKWILA NOV 2 6 2012 PERMIT CENTER CONSULTANT FIRM FLOOR' Ye DPWE ROOM MICHAEL BAKER JR. INC. 2929 NORTH CENTRAL AVENUE STE. 800. PHOENIX, ARIZONA 85012 (602) 279 -1234 STAMP MECHANICALIELECTRICAL ENGINEERING a BUILD JMILA'CYBER - INTERIOR UPGRADES STREET ADDRES 6101 SOUTH 180TH. STREET CITY, STATE TUKWILA, WA. 98188 COMMUNICATIONS ENGINEERING CONSULTANTS PHOENIX AZ COLUMBUS OH 2575 CAMELBACK ROAD 6820 LAUFFER ROAD PHOENIX ARIZONA 86018 COLUMBUS 0H1043231 P:602343.7414 P:614.392.2902 F:802.3432301 _ F:814.382.2607 ISSUED FOR DESCRIPTION MECHANICAL & FP PLANS CONSULTANT NAME NOTICE The Information contained herein should not be disclosed to unauthorized persons. It Is meant for use by authorized representatives of CenturyLlnk' DATE JOB NO 10/04/12 FILE NAME SHEET NO