Loading...
HomeMy WebLinkAboutPermit M12-188 - POLL BUILDINGPOLL BUILDING 3920 S 146 ST M12 -188 City otTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0040000254 Address: 3920 S 146 ST TUKW Project Name: POLL BUILDING Permit Number: M12 -188 Issue Date: 02/11/2013 Permit Expires On: 08/10/2013 Owner: Name: POLL TUKWILA LLC Address: 8915 SE 44TH ST , MERCER ISLAND WA 98040 Contact Person: Name: JEREMY MOELLER Address: PO BOX 3205 , KIRKLAND WA 98083 Email: JEREMY @CFM- HVAC.COM Contractor: Name: C F M HEATING AND COOLING INC Address: PO BOX 3205 , KIRKLAND WA 98083 Contractor License No: CFMHEHC969CD Phone: 425 - 821 -1293 Phone: 425 821 -1293 Expiration Date: 02/04/2014 DESCRIPTION OF WORK: INSTALL (2) NEW ROOFTOP HEAT PUMPS Value of Mechanical: $12,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $330.56 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and xamined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie withf whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: er Date: 7/-7:3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -188 Printed: 02 -11 -2013 • PERMIT CONDITIONS Permit No. M12-188 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -188 Printed: 02 -11 -2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd.. Suite 100 Tukwila. W4 98/88 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: m x- I 06 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: 3920 5. lzhoth Tenant Name: ?011 6u&ii(�a PROPERTY OWNER Company Name: C FM Keadi 5 and cool. m3 Name: p0 i ( Tukw:1G LL G City: Kc v LLnU State: to Zip: 760t33 Address: Se/I5- sr iiYt . &t Contr Reg No.: CFM H tiCgb/CO Exp Date: 02 /et b `f City: 1 "C2r ISL1661 State: 6vA Zip: qp,D CONTACT PERSON - person receiving all project ,communication Company Name: C FM Keadi 5 and cool. m3 Name: —ere 01 Meci(er City: Kc v LLnU State: to Zip: 760t33 Address: � p 6m 3zo $ Contr Reg No.: CFM H tiCgb/CO Exp Date: 02 /et b `f City: K, or kiwi � ulll ( State: 1. ,n Zip: 13 Phone: [s, 62„I- 1243 Fax: fZ5 521-133 Email: erenty (' C''m- 111/4C r, can King Co Assessor's Tax No.: 00i/000-0251i Suite Number: Floor: New Tenant: ❑ Yes ®..No MECHANICAL CONTRACTOR INFORMATION Company Name: C FM Keadi 5 and cool. m3 Address: r, p, Box 3zo5 �J City: Kc v LLnU State: to Zip: 760t33 Phone: 25'621 -12 '3 Fax: 1f25, pi- 13Y3 Contr Reg No.: CFM H tiCgb/CO Exp Date: 02 /et b `f Tukwila Business License No.: OpttM 'I Valuation of project (contractor's bid price): $ 2, 000 Describe the scope of work in detail: a-As -1411 2 66,0 C'oo1 Use: Residential: New ❑ Commercial: New Replacement Replacement lr\e4+ e p Fuel Type: Electric ® Gas ❑ Other: HA Applications s- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type .r,. Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended /wall/floor mounted heater Appliance vent Repair or addition to headrefrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN R OR AUT 1, ED AGENT: / Signature: iH /� Date: 1/- Z7" /2 Print Name: JJeremy /lDf'lI2( Day Telephone: /Z' 82/- 12113 D Mailing Address: r •o• Bog, 32D5- / rk)a"f% Lov1 ?oo 3 H:\Applications\Forna- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8- 9.11.docx Revised: August 2011 bh City State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0040000254 Address: 3920 S 146 ST TUKW Suite No: Applicant: POLL BUILDING RECEIPT Permit Number: M12 -188 Status: PENDING Applied Date: 11/27/2012 Issue Date: Receipt No.: R12 -03199 Payment Amount: $330.56 Initials: WER Payment Date: 11/27/2012 03:28 PM User ID: 1655 Balance: $0.00 Payee: CFM HEATING AND COOLING INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7279 330.56 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 264.45 000.345.830 66.11 Total: $330.56 Harr RPrpint -f1R PrintPri• 11- 97_7f119 INSPECTION RECORD`. Retain a copy with permit INSPECTION NO. .. PERMIT NO. CITY OF TUKWILA BUILDING:: DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 z- (206)'431 -3670 Permit Inspection Request Line (206) 431 -2451 P ject:1 t Tye -of Inspection:.. Ad,c.Ae: 7/6 Special Instructions: Date Wanted.. ' ^.1':. C' —a.m.: p.m. Requester: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Inspector: t if Dater v REINSPECTION FEE REQUIRED. Prior to next inspection.. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. FILEC ^— ...e.. r PY STRUCTURAL CALCULATIONS FOR 3920. 146TH STREET - RTU TUKWILA, WASHINGTON PREPARED FOR: ADATTO CONSTRUCTION JANUARY 18 2013 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 0 2013 CASCADE CREST CONSULTING ENGINEERS. INC. 21902 96" AVENUE SE SNOHOMISH, WASHINGTON 98296. (296) 909 -7808 PREPARED BY: KEITH MOORE, S.E. CORRECTION r. —WA ,0 `" . \N M. ^'A , ?, ( ii �,ro ry Nj P+^ ft SS/O �NG\� : NAL • 0,..A' kd 70. lLr(,- EXPIRES M 1 )-%. 189 RECEIVED CITY OF TUKVVILA JAN 2 3 2013 PERMIT CENTER CASCADE CREST CONSULTING ;ENGINEERS. INC. PROJECT: 5qZ 2 Imo -roleAvi LA, ENGR:L\f DATE: 8l.I SCALE: SHEET Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.473 Longitude = - 122.28400000000002 Spectral Response. Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class 'B - Fa = 1.0 ,Fv = 1.0 Data are based on 'a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 1A63 (Ss, Site Class B) 1.0 0.503 (S1, Site Class B) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.473 Longitude := - 122.28400000000002 Spectral Response Accelerations SMs and SM1 SMs =FaxSs and SMI =FvxS1 Site Class C Fa = 1.0 , Fv = 1.3 Period Sa (sec) (g) . 0.2 1.463 (SMs,. Site Class C) 1.0 0.654 (SM1, Site Class C) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.473 Longitude = - 122.28400000000002 Design Spectral Response. Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 = 2/3 x SM1 Site Class C Fa = 1.0 Fv = °1.3: Period Sa (sec) (g) 0.2 0.975 (SDs, Site Class C) 1.0. 0.436 (SDI, Site Class C) YORm BHZ -13 SEER SingleAffinity Pkg. R-410A HP Page: 3 Project Name: dave 3 -3 ton quote Purchaser. Dave Model #: .B2HZ036A06 Quantity: 3 System: B2HZ036A06 Cooling Performance Total capacity Sensible capacity Refrigerant type Seasonal Efficiency (at ARI) Efficiency (at ARI) Ambient DB temp. Entering DB temp. Entering WB temp. Leaving 0B temp. Leaving WB temp. Power input Sound power 36.7 MBH 28.7 MBH R410A 13.00 SEER 11.00 EER 85 °F 80 °F 67 °F 57.9 °F 57.3 °F 2.70 kW 78 d8(A) 4 Heat Pump Performance Capacity @ 47 °F 32.80 MBH HSPF 7.7 Capacity @ 17 °F 19.20 MBH COP @ 17 °F 2.30 COP 47 °F 3.00 Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 17.1 MBH Nominal electric heat 5.00 kW Applied electric, heat 5.0 kW Installed Field Leaving DB temp. . 73.2 °F Air temp. rise 13.2 °F Supply Air Blower Performance Supply air . . Ext. static pressure Unit static resistance Blower speed Blower speed description Duct location Motor rating Actual required BHP Power input Elevation Drive type Electrical Data Power supply Min circuit ampacity Max over- current protection 1200 CFM 0.86 IWG 0:11 IWG 1064 RPM• Hi Bottom 0.75 HP 0.75 HP 0.52 kW 433 ft. DIRECT 230 -1-60 52.50 Amps 60 Amps Dimensions & Weight Hgt 34 In. . . Len 49 in. Wth 47 in. Weight with factory installed options 385 lbs. Clearances Right 24 in. Front 12 in. Top, 36 In. Bottom 0 in. Back 0 in. Left 24 in. • 3Ton • YORK Affinity® Series packaged units are manufactured at an ISO 9001 registered facility and each rooftop is completely computer -run tested prior to shipment. STANDARD FEATURES • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM 8-117 Standards). • Single speed scroll compressor • ECM 2.3 (Variable speed direct drive high static motor and slide out blower • assembly) • Field convertible duct connections from horizontal to downflow allows greater flexibility. • Bottom and side electrical and gas utility connections. • Non - corrosive condensate pan internally sloped to meet strict requirements of ASHRAE 62 -89 indoor Air Quality standard:. • Full perimeter, removable base rails with built in rigging and access provisions. • Low operating sound level • Single point power connection . • Refrigerant access ports externally accessible • Easy access to all components • Single piece water -shed top cover and drip edge • Condenser coil grille Standard cooling operation down to 45 °F Compressor is internally protected against high pressure . and temperature. won, tasuGersritlysleat ama Made In USA APJ amxam, WARRANTY • Ten (10) Years on the Compressor. • Five (5) Years Limited Parts • Extended Ten (10) Year Limited Parts Warranty when product is registered online within 90 days of purchase for replacement or closing for new home construction. This Warranty does not apply for R-22 or 3-Phase systems:, Ureter/ Sales Tool v1.5.3.0 Information Is subject to change without notice. Check local codes. Printed 815/2011 rl YORK Affinity BHZ -13 SEER Single Pkg. R-410A HP Page: 8.. Project Name: dave 3 =3 ton quote Purchaser: Dave Model # B2HZ036A06 Quantity: • 3 System: , B2HZ036A06 Unit Weights and Center of Gravity Unit 4 Point Load Weight CENTER OF GRAVITY FRONT OF UNIT 49 -118 � . X Size (Tons) Model Weigh (Ibs.) Center of Gravity 4 Point Load Location (Ibs.) Shipping Operating X Y A B C ; :: p 024 (2.0) : BHZ 360 355 22.25 25 I 96 84 81 93 BHQ 360 355. 22.25 25 96 84 81 .: 93 BHX 385 380 22.25 25 103 90 . 87 100 030 (2.5) BHZ 355 350 22.25 25 96 84 81 . 93 BHQ 380 375 22.25 25 102 89 86 98 036 (3:0) BHZ 395 390 22.25 25 106 92 89 102 BHQ 405 400 22.25 25 109 95 92. 105 BHX 405 400 21.75 24.25 108 90 92 110 .' 042 (3.5) BHZ 445 440 22.25 25 120 104 101. 115 BHQ 425 420 22.25 25 . 114 100 96 110 048 (4.0) BHZ 490 485 22.25 25 132 115 111 127 BHQ 445 440 22.25 25 120 104 101 115 BHX 445 440 22 26 126 107 95 112 060 (5.0} BHZ 500 495 22.25 25 135 137 117 122 113 —_ 109 130 _.122 BHQ 495 490 22.25 26 BHX 465 460 22 26.25 133 113. 99 ' 116 Unit Accessory Weights Unit Accessory Model Weight (Ibs:) Shipping .Operating, Add Economizer All 4$ 40 Add Electric Heat', .. .BHX, BHQ and BHZ 13 12 1. Weight given is for the maximum heater size available (25 kW). Unitary Sales Tool v1.5.3.0 Information is subject to change without notice. Check local codes. ' Printed' 815/2011 ��1 :-54 . (., b e Q6•.{.; Sf�.�V�^�� • Yr�lc (e1.51/-1,51./. � t)Ni 4' I= ot. 4 .rse3A.,1".:;( re- lamk- ilt wttis CASCADE CREST CONSULTING ENQINEERs. INC. 1 �3oA joiod N-lj-rr ;� � c. c r 1 h 414 . I 4(.; \��.tc..t..�.lAltf �I!•tl?c.. iF la € l\ \(;':- -)i), C�t� - .1J :CA -"C v. oft, 014 rr !CX.i3 4 OR Crrti cC.._ 1be: OP, :or -ran:. 44,1 L . ?ate. 4 ". °. 2'J 4. S'as LJp I� p /;I": • clr. PROJECT: CI 40 144(04--A ENGR: ! (( p/11 SCALE: r. SHEET CASCADL CREST CONSULTRlG ENOINE6R8. INC. PROJECT:. vv( ENGR: 1 -CV' DATE: r 3%(.."7( I�_ SCALE: GENERAL STRUCTURAL NOTES:. ALL MATERIALS , WORKMANSHIP, DESIGN, AND CONSTRUCTION; SHALL. CONFORM T0. THE DRAWINGS AND THE.INTERNATIONAI, BUILDING CODE (IBC), 2009 EDITION. DESIGN LOADING CRITERIA: ROOF .LIVE LOAD 25 PSF MECHANICAL UNIT 460 POUNDS EARTHQUAKE SDS = 0.975 SITE CLASS B WIND 85 MPH, EXPOSURE B STRUCTURAL .DRAWINGS SHAI.,L BE USED IN CONJUNCTION WITH.MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER. OF ALL DISCREPANCIES PRIOR: TO CONSTRUCTION. ION. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN IN THE CALCULATIONS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN IN THE CALCULATIONS. ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS. OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. I.F THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN IN THE CALCULATIONS, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO:COMMENCING:ANY WORK, CONTRACTOR SHALL .PROVIDE TEMPORARY BRACING' FOR THE STRUCTURE AND.:: STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED .FOR THE COMPLETION OF THE WORK. 7. THE NEW UNIT TO THE METAL CURB WITH TWO (2). #10 SHEET METAL SCREWS PER SIDE. CONNECT THE METAL CURB TO THE EXISTING ROOF DECK WITH TWO (2) #10 x 1 -1/2" WOOD SCREWS. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTI I'UTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD - FORMED STEEL STRUCTURAL MEMBERS ". 9. WOOD SCREWS SHALL CONFORM TO ANSI /ASME STANDARD B.8.6.1. P i'i'i j' t rt I . �1A 77- 1 1 1 I I I I iui 4 a1-<1 a l I j I!! 9l�ti r tlj "�i 1111"1 illj! 211111i Hilt 1 11.1' 1 I I_i j i PI I !'! I 11 1 I[ iIllIjl Iliill II Ijjlilii I'il(i.I 1 .111 ! I I'I.i j f 11 f1111 11111 _0 0 (n m n 0 z tl 5i' 0 1 POLL BUILDING 3920 1 46th St. TUKWILA. WA. ROOF; PLAN FOR HVAC CASCADE CREST CONSUL.TING ENGINEERS, INC. 21902 9519 AVE. 6E. 944aI0■1SN. WA. 58295 (9) .206 905 =7205 December 14, 2012 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Jeremy Moeller CFM Heating and Cooling PO Box 3205 Kirkland, WA 98083 RE: Correction Letter #1 Mechanical Permit Application Number M12 -188 Poll Building — 3920 S 146 St Dear Mr. Moeller, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician File No. M12-188 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: December 4, 2012 Project Name: Poll Building Permit # M12 -188 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. The engineer's calcs, state to place the units within 4 feet of a support point. The rooftop plan provided does not show support points. I talked to the engineer and a support point would be a bearing wall or post. Please show the location of bearing members to support the location of the HVAC units. Should there be questions concerning the above information please contact the Building Division at 206 - 431 -3670. 13thfiin I Ca D C PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -188 DATE: 01 -23 -13 PROJECT NAME: POLL BUILDING SITE ADDRESS: 3920 S 146 ST Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: r-5 L building ivision Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 01 -24 -13 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved fl Approved with Conditions Notation: DUE DATE: 02 -21 -13 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PEWS CO COPY • • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -188 PROJECT NAME: - POLL BUILDING SITE ADDRESS': 3920 S 146 ST X Original Plan Submittal Response to Correction Letter # _ DATE: 11 -27 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPAF�TME ( I _'� Building Division • Public Works ❑ Fire Prevention up Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -29 -12 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Ela Structural Review Required ❑ No further Review Required r1 REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12 -27 -12 Approved ❑ Approved with Conditions n Not Approved (attach comments) JX/ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 1)--- LA— t Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 01- 23— 13 Plan Check/Permit Number: M12-188 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Poll Building Project Address: 3920 S 146 St _ /25' 801- i293 Contact Person: JP/CP.01y /J1r Phone Number: Summary of Revision: !p eon C.4br 41 rn1 01 a b : i k , : IT 'ef 61-01,4...1.(15 s1)6r4 PD'rb -0-or FrogpstC( \roe G 91,1,1-$ Sheet Number(s): "Cloud" or highlight all areas of revision including date of evision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on RECEIVED JAN 23 2013 COMMl1NI 1 Y DEVELOPMENT \applications \forms- applications on Iine\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople tinter Friendly Page u General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name C F M HEATING AND COOLING INC UBI No. 602361244 Phone 4258211293 Status Active Address Po Box 3205 License No. CFMHEHC969CD Suite /Apt. License Type Construction Contractor City Kirkland Effective Date 2/4/2004 State WA Expiration Date 2/4/2014 Zip 98083 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date CLANCY, SHAUN P President 02/04/2004 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 DEVELOPERS SURETY & INDEM CO 798903C 02/04/2009 Until Cancelled $12,000.0012/17 /2008 1 RLI INS CO SRS1008639 02/04/2004 02/04/2009 03/12/2009 $12,000.0002/04 /2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 AMERICAN FIRE & CASUALTY CO BKA54333410 02/04/2011 02/04/2014 $1,000,000.00 01/14/2013 7 Continental Western Ins Co CNP2739229 02/04/2008 02/04/2011 $1,000,000.00 01/05/2010 6 OOHIO CAS INS BKW53560669 02/04/2007 02/04/2008 $1,000,000.00 02/05/2007 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 02/11/2013 ADJACENT BUILDING AREA OF WORK ON ROOF EXISTING BUILDING EXISTING PARKING LOT S 146TH ST. SITE PLAN SCALE:1/16"=1'0" SEPARATE PERMIT REQUIRED FOR: 0 Me-chanical iniectrical GloPlumbing 41as Piping City of Tukwila UILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. novisions will require a new plan submittal and may inc!ude additional plan review fees. FILE COPY Permft No. tokia---198 rviaw approval is subject-to errors and ornissions, of construction documents does not author•e -,,.:',Yatiort of any adopted code or ordinance. Receipt oi 42roVeci Fie! 4 py and It I t is admowledgc [1: ft..- 4( Date: LEGAL DESCRIPTION: ADAMS HOME TRS POR ELY OF HWY LESS N 210 FEET LESS E 10 FEET THOF ESS S 10 FEET LESS ST PARCEL. NUMBER: 004000-0254 City Of Itikwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 0 2013 City of Tukwila BUILDING DIVISION t8g RECEIVED CITY OF TUKWILA NOV 2 7 2012 PERMIT CENTER SET DATE: 11-7-12 REVISION I I 1 I 1 I s' JOB NUMBER cJ CHECKED BY 0(0. z E *cc- co u) -1 0 D • < D o LL z 0 • _J ci z 0 z 2 0 0 110 O z LU SHEET NUMBER Al .0 CONTRACTOR'S LICENSE CFMHEHC069CD ABBREVIATIONS AC AD AFC AFF AHU AL BDD BFC BHP BI BOD BTU BTUH CFM CO CV CW CRD AIR CONDITIONING ACCESS DOOR ABOVE FINISHED CEILING ABOVE FINISHED FLOOR AIR HANDLING UNIT ALUMINIUM BACK DRAFT DAMPER BELOW FINISHED CEILING BRAKE HORSE POWER BACKWARD INCLINED BOTTOM OF DUCT BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR CUBIC FEET PER MINUTE CLEAN OUT CONSTANT VOLUME COLD WATER CEILING RADIATION DAMPER DIA DIAMETER DIM DIMENSION DMPR DAMPER DN DOWN DP DIFFERENTIAL PRESSURE DWG DRAWING EX EXISTING EAT ENTERING AIR TEMPERATURE EF EXHAUST FAN EFF EFFICIENT, EFFICIENCY EG EXHAUST GRILLE ELEC ELECTRICAL FG FLOOR GRILL FD FIRE DAMPER F FURNACE FPM FEET PER MINUTE FSK FOIL SKRIM KRAFT LINER (SPUNSTRAND) FT FEET, FOOT G GR HP HR HPID HPOD HTG HVAC GAS GRILLE HORSE POWER HOUR HEAT PUMP INDOOR UNIT HEAT PUMP OUTDOOR UNIT HEATING HEATING, VENTIALTION AND AIR CONDTIONING HW HOT WATER ID IN INFO INSUL JAN KW KWH LA LVG MA MBH MAT MAX MECH MIN MISC N NA N TS OSA OAT OD OPP OV PD PERF PF PH QTY RA REQD RET RGM SA SCHED SD SF SFD S.LO SHT SP 5REC SS STAT TEMP TK TEMP THRU TSTAT TYP INSIDE DIMENSION INCH, INCHES INFORMATION INSULATE, INSULATION JANITOR KILOWATT KILOWATT HOUR LEAVING AIR TEMPERATURE LINEAL FEET LEAVING MIXED AIR THOUSAND BRITISH THERMAL UNITS PER HOUR MIXED AIR TEMPERATURE MAXIMUM MECHANICAL MINIMUM, MINUTE MISCELLANEOUS NORTH NOT APPLICABLE NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE OUTSIDE DIMENSION OPPOSITE OUTLET VELOCITY PRESSURE DROP PERFORATED PRE FILTER PHASE QUANTITY RETURN AIR REQUIRED RETURN REVOLUTIONS PER MINUTE RETURN GRILLE SUPPLY AIR SCHEDULE SMOKE DETECTOR SUPPLY FAN SMOKE /FIRE DAMPER SUPPLIED & INSTALLED BY OWNER/ (OTHER) SHEET STATIC PRESSURE SPECIFICATION SUPPLY REGISTER STAINLESS STEEL THERMOSTAT TEMPERATURE TOE KICK TEMPORARY THROUGH THERMOSTAT TYPICAL UL UNDERWRITER'S LABORITORY UV UNIT VENTILATOR V VAC VDC V/D VAC VAV VEL VOL W/ W/0 WB WC VOLT VOLTS AC VOLTS DC VOLUME DAMPER VACCUUM VARIABLE AIR VOLUME VELOCITY VOLUME WITH WITHOUT WET BULB WATER CLOSET MECHANICAL SPECIFICATION GENERAL SCOPE THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL MECHANICAL SYSTEM. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO COMPLETE THE MECHANICAL WORK. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW OFFSETS WHICH MAY BE REQUIRED. SITE EXAMINATION THE MECHANICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, DUCTWORK, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION NAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE MECHANICAL WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ARL, ASME, ASTM, UL, NEMA, ANSO, SMACNA, ASHRAE, NFPA, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS /SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE MECHANICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO THE OWNER. PERMITS AND FEES THE MECHANICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE MECHANICAL WORK. WARRANTY THE MECHANICAL CONTRACTOR SHALL UNCONDITIONIALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY OWNER, AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND SHALL RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. DUCTWORK AND ACCESSORIES SHEET METAL DUCTWORK ALL DUCTWORK TO BE RIGID SHEET METAL CONSTRUCTED FROM GALVANIZED SHEET STEEL IN ACCORDANCE WITH SMACNA LOW VELOCITY DUCT CONSTRUCTION STANDARDS. ALL EXPOSED DUCTWORK TO BE ROUND, SPIRAL LOCK SEAM TYPE. ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AIR TIGHT (8% LEAKAGE) AND NOISELESS (NO OBJECTIONABLE NOISE) SYSTEMS CAPABLE OF PERFORMING EACH INDICATED SERVICE. FURNISH ALL DAMPERS, TRANSITIONS, CONNECTIONS TO AIR TERMINALS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE OPERATING SYSTEM. NO VARIATION OF DUCT CONFIGURATION OR SIZES WILL BE PERMITTED EXCEPT BY PERMISSION FROM THE ENGINEER. DUCT SEALANT SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS WITH A NON- HARDENING, NON- MIGRATING MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE RECOMMENDED BY THE MANUFACTURER FOR SEALING JOINTS AND SEAMS IN SHEET METAL DUCTWORK. COVER ALL FIELD JOINTS, JOINTS AROUND SPIN -IN FITTINGS, AND FASTENING SCREWS WITH MASTIC. SUPPORTS: PROVIDE HOT- DIPPED GALVANIZED STEEL, FASTENERS, ANCHORS, RODS, STRAPS, TRIM, AND ANGLES FOR SUPPORT OF DUCTWORK. DAMPERS PROVIDE OPPOSED- BLADE, MULTI -LEAF VOLUME CONTROL DAMPERS WHERE INDICATED ON DRAWINGS AND AT POINTS ON LOW PRESSURE SUPPLY, RETURN, AND EXHAUST DUCTS WHERE BRANCHES ARE TAKEN FROM LARGER DUCTS. PROVIED UL LISTED FIRE DAMPERS WHERE REQUIRED AND IN ACCORDANCE WITH NFPA AND LOCAL CODES. PROVIDE CONVEINIENTLY LOCATED ACCESS DOORS OF AMPLE SIZE AND QUANTITY FOR SERVICING THE DAMPERS. GRILLES, REGISTERS & DIFFUSERS GRILLES, REGISTERS, AND DIFFUSERS SHALL BE INSTALED AS INDICATED ON THE DRAWINGS AND SCHEDULES. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS ITEMS NECESSARY FOR A COMPLETE AND PROPER INSTALLATION IN THE TYPE OF CEILING AND WALLS USED IN THIS PROJECT. THERMAL INSULATION PROVIDE EXTERNAL THERMAL INSULATION WITH AN INTEGRAL VAPOR BARRIER FACING OF SUFFICIENT THICKNESS TO MEET LOCAL ENERGY CODE REQUIREMENTS. PROVIDE INSULATION ON EXHAUST AND OUTSIDE AIR DUCTS, AND ON CONCEALED PORTIONS OF SUPPLY AND RETURN AIR DUCTS. DO NOT INSULATE EXPOSED DUCTWORK AND PORTIONS OF DUCTWORK THAT ARE INTERNALLY LINED. THERMAL INSULATION TO COMPLY WITH AN NFPA FLAME SPREAD OF 25 OR LESS, AND SMOKE DEVELOPED NO GREATER THAN 50. ACCOUSTICAL DUCT LINER: UNLESS OTHERWISE INDICATED ON THE PLANS, PROVIDE 1" GLASS FIBER ACCOUSTICAL DUCT LINER ON SUPPLY AND RETURN DUCTWORK WITHIN 10 FEET OF THE DISCHARGE AND INTAKE OF AIR HANDLING UNITS. INCREASE DUCT SIZE INDICATED ON PLANS 2" IN EACH DIMENSION TO ACCOMODATE LINER. TESTING, ADJUSTING, BALANCING MECHANICAL CONTRACTOR OR AN INDEPENDENT NEBB OR AABE CERTIFIED AIR BALANCE CONTRACTOR SHALL ACCURATELY BALANCE THE AIR SYSTEMS TO PROVIDE AIR QUANTITIED INDICATED ON THE DRAWINGS AND IN THIS SPECIFICATION. OPERATE AUTOMATIC CONTROLS SYSTEM AND VERIFY SET POINTS DURING BALANCING. SUBMIT TWO (2) COPIES OF THE BALANCE REPORT TO THE ENGINEER FOR APPROVAL. INCLUDE A COPY OFi THE BALANCE REPORT AS APPROVED BY THE ENGINEER WITH APPLICATION FOR 'FINAL CONTRACT PAYMENT. WSEC NOTES THERMOSTATS SHALL BE INTERLOCKED TO PREVENT SIMULTANEOUS HEATING AND COOLING PER WSEC 1422. ECONOMIZERS SHALL MODULATE OUTSIDE AIR FROM MINIMUM TO 100% PER WSEC 1413.1 ECONOMIZER CONTROLS SHALL BE CAPABLE OF EVALUATING OUTDOOR AIR COOLING CAPACITY PER WSEC 1413.2 GENERAL CONTRACTOR TO PROVIDE ACCESS TO FIRE AND /OR COMBINATION FIRE /SMOKE DAMPERS. INSULATE REFRIGERANT PIPING PER WSEC, TABLE 14 -6. SEAL DUCTWORK PER WSEC 1414.1 INSULATE DUCTWORK PER WSEC TABLE 14 -5. PACKAGED ROOFTOP HEAT PUMP SCHEDULE MARK MAKE MODEL CFM SP. COOLING HEATING ELECTRICAL WEIGHT ECONO TOTAL SENS (S)EER INPUT CAP @ 1 7° HSPF DATA FUSE M.C.A. HP -1 YORK B2HZ036A06 1200 .50" 36.7 28.7 13.00 SEER 32.80 19.20 7.7 230 -1 -60 60 52.5 460 LBS. YES HP -2 YORK B2HZ036A06 1200 .50" 36.70 28.7 13.00 SEER 32.80 19.20 7.7 230 -1 -60 60 52.5 460 LBS.I YES HVAC NOTES: 1. HP -1 & HP -2 ARE NEW UNITS FOR EXPANSION TENANT IMPROVEMENT 2. DUCTWORK DISTRIBUTION INSIDE OF SPACE IS UNDER FUTURE PERMIT 3. SCOPE OF WORK INCLUDES INSTALLATION OF ROOFTOP CURBS, HEAT PUMPS, AND SUPPLY AND RETURN DROPS SECURE LE DECKING W/ SCREWS(1 A/C UNIT UNIT CURB CURB INSULATION URB LEVELING FRAME LING FRAMES TO ELF TAPPING EACH CORNER) 2X4 CROSS BRACE SECURE A/C CURB TO ROOF DECK W/ 8d WOOD SCREWS 0 8" O.C.(TYP. ALL. FOUR SIDES OF CURB). DO NOT PENETRATE COMPLETELY IF ROOF DECK IS VISIBLE FROM BELOW ROOF DECK ISOLATION GASKET RUBATEX MODEL R -422N 1 /r THICK 2" WIDE W/PRESSURE SENSITIVE ADHESIVE ON ONE SIDE, CONT. ENTIRE PERIMETER OF CURB /C UNIT RAIL SECURE AJC UNIT TO CURB W/ /8" X 4 LONG BOLT, 2 EA SIDE OF UNIT OR #10 SHEET METAL SCREWS 0 24" 0.C. ETAL FLASHING `OOFING MATERIAL Pr TYPICAL ROOFTOP UNIT MOUNTING SCALE: NONE DRAWING SYMBOLS North NORTH ARROW SECTION IDENTIFICATION SHEET IDENTIFICATION COLUMN GRID SYMBOLS GENERAL MECHANICAL NOTES NUMBER IDENTIFICATION FLAG MECHANICAL NOTES NUMBER IDENTIFICATION MECHANICAL LEGEND SYMBOL. 12X8 + ' I 1 14. T Iwv DESCRIPTION INFORMATIONR UGHT UN16ROUND NEW WORK (HEAVY UNE) OR DEVICE NDICAIE60UIPMENT ITEM TO BliNSEL irlaLYTDEMODUSH DORK POINT OF NEW CONNECTION HAUST FANS HOWN3SIGNATION ROOM/ZONE THERMOSTAT NDTF UST EW' 2IGURE �IDE NO SHOI FLEXIBLE CONNECTION VOLUME DAMPER 45' TAKE -OFF 45' RECTANGULAR TAKE -OFF WITH TAPER FLEXIBLE DUCT MOTORIZED DAMPER COMBINATION SMOKE/FIRE DAMPER FIRE DAMPER DCRD CEIUNG DIFFUSER OR GRILLE RADIATION DAMPER TERMINALS: L1 trail FULA WAN TYP 2 RL--- RS - - -C - -- 8 IUNGCKDIFFUSER, TYPE 1 BALANCE TO 350 CFM RETURN GRILLE, TYPE 1 BALA2NCE NE TO 350 CFM TRANSFER GRILL, TYPE 1 24x12 NECK BALANCE TO 350 CFM TYPICAL. OF 2 DIFFUSER CEIUNG RETURN GRILLE CEIUNG EXHAUST GRILLE REFRIGERANT LIQUID LINE REFRIGERANT SUCTION LINE CONDENSATE PIPING SHEET INDEX MO.1 MECHANICAL SCHEDULES M1.0 HVAC ROOF PLAN REVIEWED FOR CODE COMPLIANCE b ` APPROVED JAN 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 2 7 2012 PERMIT CENTER Maft- 189 SET DATE: 11 -27 -12 REVISION I- 0 0 z 2 z Z U O g N JEREMY MOELLER 0 Y W U ■ 0: 0 • w J 1- 1- HVAC SCHEDULES C7 0 CD Z U.0 U °6 SHEET NUMBER CONTRACTOR'S LICENSE CFMHEHC969CD EXISTING No 51-d, I 1 ec%ani e, P71 . Zdt`e"1-) I a /-7.'cq d t4-- 6 $71-66-1" 4jf /a47Gf'7"5 c' tke,E"7 '4 >- i- i/>e me/W 14,411 need -11-207 %- $ Sf- e41a4 7 -- ,� /7)11/4-6--- Lhe.0 ?L u) /.-7 42 4-01-74e,9-1— a / �et kein r rk? / f3 ROOFTOP UNIT EXISTING ROOFTOP UNIT EXISTING ROOFTOP UNIT EXISTING ROOFTOP UNIT HVAC ROOF PLAN SCALE:1 /8 " =1'0" Nort REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 0 2013 City of Tukwila BUILDING DIVISION M 2:%-- 8 El RECEIVED CITY OF TUKWILA NOV 2 7 2012 PERMIT CENTER SET DATE: 11 -27 -12 REVISION W 0 0 JOB NUMBER m U W • CC 0 • w HVAC ROOF PLAN U W 0 0 N E zo 8 0 U LU U • i U ncc SHEET NUMBER M1 .0 CONTRACTORS LICENSE CFMHEHC969CD M i; 7 HVAC UNIT 3 TON YORK # B2HZ036A06 WEIGHTS CURB WT 75 LBS UNIT WT 385 LBS i /- 1—r ■ N N 1 ' v ,- N N. �' �N N 1 N, N iA N. N ��� N N N N. N N - - 1 N. --- �' N_ I EXISTING 5/8" PLY SHEATHING �TTT LL �\ N N N T T J. 1 S N 6 5/8" X 25 1/2" GL BEAM 8a`0" ROOF SECTION 1/2" = 1' -0" 1/2" PLYWOOD SHEATHING BLOCK ALL EDGES NAILING 8d OC, ON ALL 2X4 CORDS, TOP , EDGES AND BOTTOM § O - � - - - —F= - -- _.SECTION - -- 6 " x 18" GL STRUT - -- -mac- - -- — - - -- - - -- N - i SECTION S2) 2X4 WOOD TRUSSES ±1irT1TTTrTr a - 0 1 1 1 1 1 I I 1 I t / 2 4 4000 TRUSSES AT 2' =6 1 I I I I I 1 Il l 0. C. los 0 'M 4' -0" 31' –O" ROOF PLAk1 1/8" = 1' -0" 1 0 (0 J REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA CORRECTION LTR # JAN 73 2013 �_ PERMIT CENTER VI I 1-- B U Z (1) fh W IW (f) Z ooN 0, Z co UW w • o°o W a Q � (-) I= o < Z In C.) (f) NI N Q� rnZ a U N U) ... Z 0 0 0 ri; z — }Q 3 N J1J o §_ OOD ROOF PLAN FOR HVAC