HomeMy WebLinkAboutPermit PG12-018 - WESTFIELD - SOUTHCENTER MALLSOUTHCENTER MALL 2800 SOUTHCENTER MALL PG12 -018 City olgII'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov PLUMBING /GAS PIPING PERMIT Parcel No.: 9202470010 Address: 2800 SOUTHCENTER MALL TUKW Project Name: WESTFIELD - SOUTHCENTER MALL Permit Number: PG 12 -018 Issue Date: 02/24/2012 Permit Expires On: 08/22/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: DARLA DOLL Address: 7717 DETROIT AV SW , SEATTLE WA 98106 Email: DARLA.DOLL @MACMILLER.COM Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA 98106 Contractor License No: MACDOFS980RU Phone: 206 -768 -4278 Phone: 206 - 768 -4180 Expiration Date: 12/31/2012 DESCRIPTION OF WORK: INSTALL ONE (1) BACKFLOW PREVENTOR 1/2" WATTS SERIES 009 REDUCED PRESSURE PRINCIPLE ASSEMBLY (RPPA) AND REPLACE ONE (1) WATTS Series 25AUB -Z3 WATER PRESSURE REDUCING VALVE(PRV). Value of Plumbing /Gas Piping: Fees Collected: Electrical Service Provided by: Permit Center Authorized Signature: $1,000.00 $77.44 Uniform Plumbing Code Edition: 2009 International Fuel Gas Code Edition: 2009 Date: 0/ �t Z I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions on the back of this permit. Signatur Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG12 -018 Printed: 02 -24 -2012 PERMIT CONDITIONS Permit No. PG 12 -018 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 14: RPPA and PTV shall be installed per manufacturer's specifications. Rppa shall be protected from freezing. 15: Upon installation and prior to final permit sign -off Reduced Pressure Principle Assembly (RPPA) shall be tested by a certified tester and copy of passing test report provided to the inspector. Thereafter, annual tests shall be performed at owner's expense, and copies of test results provided to Tukwila Water Department, 600 Minkler Blvd, Tukwila, WA 98188, phone # (206)433 -1860, fax # (206)575 -3404. doc: UPC -4/10 PG12 -018 Printed: 02 -24 -2012 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Plumbing/Gas Permit No. Project No. (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 2597000245 Site Address: 2800 SOUTHCENTER MALL TUKWILA, WA 98188 Tenant Name: WESTFIELD - SOUTHCENTER MALL Property Owners Name: WESTFIELD Mailing Address: 2800 SOUTHCENTER BLVD Suite Number: ROOF Floor: New Tenant: ❑ Yes TUKWILA City WA State ROOF „No 98188 Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: DARLA DOLL Mailing Address: 7717 DETROIT AVE SW E -Mail Address: DARLA.DOLL @MACMILLER.COM Day Telephone: SEATTLE (206) 768 -4278 WA 98106 City State Fax Number: (206) 768 -4279 Zip PLUMBING / GAS PIPING CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW Contact Person: DARLA DOLL E -Mail Address: DARLA.DOLL @MACMILLER.COM Contractor Registration Number: MACDOFS980RU SEATTLE WA City State Day Telephone: (206) 768 -4278 Fax Number: (206) 768 -4279 Expiration Date: 12/31/2012 98106 Zip •ARCHITECT OF RECORD — All.plans must be stamped by Architect of Record Company Name: N/A Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: State Zip ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW Contact Person: DARLA DOLL E -Mail Address: DARLA.DOLL @MACMILLER.COM SEATTLE WA City State Day Telephone: (206) 768 -4278 Fax Number: (206) 768 -4279 98106 Zip H:\Applications\Fonns- Applications On Ltne \2010 Applications \7 -2010 - Plumbing -Gas Ptpmg Permit Application.doc Revised: 7-2010 bh Page 1 of 2 Date Application Accepted: Valuation of Project (contractor's bid p t1 $ 1000.00 Scope of Work (please provide detailed information): INSTALL (1) BACKFLOW PREVENTOR Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: .._ Qty Fixture Type: Qty Fixture Types Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller 1.8 Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in Lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets . PERMIT' APPLICATION NOTES - • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN . ?y� ER OR AUTHO ZED AGEN Signature: .•��,�X �-- Print Name: Mailing Address: DARLA DOLL 7717 DETROIT AVE SW Date: 2 -6 -2012 Day Telephone: 206- 768 -4278 SEATTLE WA 98106 City State Zip Date Application Expires: C7 / /0_, Staff Initials: j H:\Applications\Fonns- Applications On Lme\2010 Applications \7 -2010 - Plumbing -Gas Piping Permit Apphcation.doc Revised: 7 -2010 bh Page 2 of 2 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.aov RECEIPT Parcel No.: 9202470010 Permit Number: PG 12 -018 Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 02/07/2012 Applicant: WESTFIELD - SOUTHCENTER MALL Issue Date: Receipt No.: R12 -00797 Initials: WER User ID: 1655 Payment Amount: $49.61 Payment Date: 02/24/2012 01:24 PM Balance: $0.00 Payee: MACDONALD MILLER FACILITY SOLUTIONS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3245 49.61 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000.345.830 -12.34 000.322.103.00.00 61.95 Total: $49.61 doc: Receiot -06 Printed: 02 -24 -2012 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT ParcelNo.: 9202470010 Permit Number: PG12 -018 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/07/2012 Applicant: WESTFIELD - SOUTHCENTER MALL Issue Date: Receipt No.: R12 -00541 Initials: LAW User ID: 1632 Payment Amount: $27.83 Payment Date: 02/07/2012 12:37 PM Balance: $111.30 Payee: MACDONALD- MILLER FACILITY SOLUTIONS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3226 27.83 Authorization No. ACCOUNT ITEM LIST: • Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 27.83 Total: $27.83 doc: Receipt -06 Printed: 02 -07 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. : PERMIT NO. 'CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 17... (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: • , rr T Type of Inspection: Address: • • D Date Called: -.> Special instructions: D Date Wanted:. a a.m. Requester: Phone No: .2.vC'SIC> —-',g1(... Approved per applicable codes. E Corrections required prior to approval. COMMENTS: 1A.,, r10- 0.4ple4P %ht:v.i L•: Inspector: '�fCn VILA l Cc..J Date: 3- 2- ° =I 7 ntREINSPECTION FEE 1EQUIRED. Prior to next inspection, fee must be i,paid.at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ,;INSPECTION RECORD :'Retain a copy with permit 'INSPECTION N0. :' '= PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300:Soutlicenter.Blvd:, #100, Tukwila. WA 98188 . (206) 431 -3670 Permit - Inspection Request Line (206) 431 -2451 C � 12 -Grp, c�� Project V.JGtS !e - W\o t. Type of Inspection: , t t4 L — ?itae+nt4'..J c, Address: .- " . 806 ' . ".00i1lVt.A0 Date Called: Special. Instructions: . ='- ' = Date Wanted:. 2 5-12 P.m. Requester: Phone No .0G—SIC)-43 el ca Approved per applicable codes. 'orrections required prior to approval. COMMENTS: rtcrt Lr r 4-1 ex k`i e,/ 1 { —17•4 C 3} rVk-- �ia�r�I — 1...ke,g4cv c,Q- g/e--"") Insp5 tor: Date: 0 VREINSPECTION FEEQUIRED.i$rior to next inspection. fee must be paid at 6300_Southcenter Blvd., Suite 100. Call to schedule reinspection. .c;f)\ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF•TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Projectt: �' % . C (d Type of Inspection: rfJ i"'(e_ Address: Gov 3C inn i/ Date Called: 030/i a Special Instructions: I 3 v 7 i�'? Date Wanted: . 03 %a-? //,), (m) Request ' 1A- ( �rcd e Phone No: 1,124, 5Io- 'i•/ G. ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: 3lZ$d� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. p 612` - 016 CD, MacDonald - Miller [15 FACILITY SOLUTIONS Backflow Prevention Assembly Test Report ASSEMBLY ID: /M ' /VS IC.C. PASSED ANNUAL TEST: YES ❑ NO ❑ NAME OF PREMISE 519 6V1 C.t v ?6-Arzjt c g-'"ce SERVICE ADDRESS 0.2.8a0 58. Gritirelt OfACZ- COMMERCIAL L RESIDENTIAL ❑ CITY 7 4la ZIP 98733 CONTACT PERSON Security y�a Phone �4�? S/�j -61-,36 y Fax ( ) LOCATION OF ASSEMBLY ph, �_ n-leLh DOWNSTREAM PROCESS 7367x67. /YlA Irezp DCVA ❑ RPBAA.. PVBA ❑ OTHER: NEW INSTALL si EXISTING ❑ REPLACEMENT ❑ OLD SER. # PROPER INSTALLATION? YES el NO ❑ MAKE OF ASSEMBLY WATTS MODEL QO? D 1 SERIAL NO. 3Qp28�q SIZED, O INITIAL TEST PASS go- - FAIL ❑ DCVA/RPBA CHECK DCVA/RPBA CHECK RPBA PVBA SVBA VALVE NO. 1 VALVE NO. 2 OPENED AT��( p PSID AIR OPENED AT DID NOT OPEN INLET PSID G� #1 CHECK U Q • ! PSID LEAKED ❑ TIGHT AL.- Gj g• L PSID LEAKED ❑ TIGHTS. C/r PSID ❑ AIR GAP OK? yirS NEW PARTS AND PAIRS " CLEAN REPLACE ❑ ❑ ❑ O ❑ ❑ ❑ ❑ ❑ ❑ PART CLEAN REPLACE ❑ ❑ b 0 ❑ ❑ ❑ ❑ ❑ ❑ PART CLEAN REPLACE ❑ ❑ 0 ❑ ❑ ❑ ❑ ❑ ❑ ❑ PART CHECK VALVE HELD AT PSID LEAKED ❑ CLEANED REPAIRED ❑ ❑ TEST AFTER REPAIRS PASS ❑ FAIL ❑ TIGHT ❑ LEAKED ❑ PSID 'TIGHT ❑ LEAKED ❑ PSID OPENED AT PSID AIR INLET PSID #1 CHECK PSID CHK VALVE PSID AIR GAP INSPECTION: Required minimum air gap separation provided? Yes ❑ No ❑ REMARKS: TESTERS SIGNATU TESTERS NAME (PR REPAIRED BY: FINAL TEST BY: T) Afrotweec.c..j Detector Meter Reading LINE PRESSURE CONFINED SPACE? /(/p CERT. NO. g ,itlq DATE 1-5-i! 2- Phone ev4 g s-5-- y4 87 DATE CERT. NO. DATE CALIBRATION DATE 11 / 7 / 1( GAUGE # ____ MODEL Yys*-'S SERVICE RESTORED? YES4 NO ❑ / '46, that this report is accurate, and 1 have used WAC 246- 290 -490 approved test methods and test equipment. ES -25AUB For Residential and Commercial Applications Job Name Job Location Engineer Approval SeridsaAUB -Z3 Wa3r'P"ressure Reducing Valves Sizes: 1/2" - 2" (15 - 50mm) Series 25AUB -Z3 Water Pressure Reducing Valves are designed to reduce incoming water pressure to a sensible level to protect plumbing system com- ponents and reduce water consumption. This series is suitable for water sup- ply pressures up to 300psi (21 bar) and may be adjusted from 25 — 75psi (172 — 517kPa). The standard setting is 50psi (345kPa). All parts are quickly and easily serviceable without removing the valve from the line. The standard bypass feature permits the flow of water back through the valve into the main when pressures, due to thermal expansion on the outlet side of the valve, exceed the pressure in the main. Features • Standard construction includes Z3 sealed spring cage and corrosion resistant adjusting & cage screws for outdoor /waterworks pit installations • Union inlet connection • Integral stainless steel strainer • Replaceable seat module • Bronze body construction • Serviceable in line • Bypass feature controls thermal expansion pressure** • High temperature resistant reinforced diaphragm for hot water Models l 25AUB -Z3 REC FEB 07 2012 PERMIT CENTER 25AUB -S -Z3 25AUB -DU -Z3 25AUB- S -DU -Z3 25AUB- DU- THDxPEX -Z3 25AUB -DU- CPVC -Z3 25AUB- DU -LF -Z3 NPT threaded female union inlet x NPT female outlet Solder union inlet x NPT female outlet Double Union — NPT threaded union female inlet and outlet Double Union — Solder union inlet and outlet Double Union — NPT threaded female inlet and PEX union outlet Double Union — CPVC union inlet and outlet Double union body less fittings Specifications Standard Specifications: A Water Pressure Reducing Valve with integral strainer shall be installed in the water service pipe near its entrance to the building where supply main pressure exceeds 60psi (413 kPa) to reduce it to 50psi (345 kPa) or lower. The valve shall feature a bronze body suitable for water supply pressures up to 300psi (21 bar). Provision shall be made to permit the bypass flow of water around the valve back into the main when pressures, due to thermal expansion on the outlet side of the valve, exceed the pressure in the main. Water Pressure Reducing Valve with built -in bypass check valves will be acceptable. Approved valve shall be listed to ASSE 1003 and IAPMO and certified to CSA B356. Valve shall be a Watts Regulator Company Series 25AUB -Z3.• A water saving test program concluded that reducing the supply pressure - 346kPa) resulted in a water savings of 30%. ork if inlet pressure is above 150psi (10.34 bar). PG, Contractor Approval Contractor's P.O. No Representative REVIE D-FINE OR DE COMPLIANCE OVED City of Tukwila ILDING DIVISION Bypass valve assembly for 11/4" — 2" sizes Union inlet connection Intergral stainless steel strainer EPDM diaphragm Bypass for 1/2" —1 " sizes Replaceable seat module Lead Free Specifications: A Water Pressure Reducing Valve with inte- gral strainer shall be installed in the water service pipe near its entrance to the building where supply main pressure exceeds 60psi (413 kPa) to reduce it to 50psi (345 kPa) or lower. The valve shall fea- ture a bronze body where suitable for water supply pressures up to 300psi (21 bar). The combined metal components of the valve contact- ed by potable water shall contain less than one half of one percent (0.5 %) lead by weight. Provision shall be made to permit the bypass flow of water around the valve back into the main when pressures, due to thermal expansion on the outlet side of the valve, exceed the pressure in the main. Water Pressure Reducing Valve with built -in bypass check valves will be acceptable. Approved valve shall be listed to ASSE 1003 and IAPMO and certified to CSA B356. Valve shall be a Watts Regulator Company Series LF 25AUB -Z3. WATTS® VIREGULATOR Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Materials Body: Seat: Integral Strainer: Diaphragm: Valve Disc: Bronze 1/2" -1" (15 -25mm) Replaceable engineered polymer (10% glass filled Noryl®) 11/4" -2" (32 -50mm) Replaceable stainless steel Stainless steel Reinforced EPDM EPDM Note: for LP models where application temperatures exceed 160 °F (71°C), but not over 180 °F (82 °C), a Teflon® protector should be added to sizes 11/4 " -2" (32- 50mm). Pressure - Temperature Temperature Range: 33 °F - 160 °F (5 °C - 71 °C) Maximum Working Pressure: 300psi (21 bars) Adjustable Reduced Pressure Range: 25 -75psi (172 - 517kPa) Standard Reduced Pressure Setting: 50psi (345kPa) Options Add Suffix G Gauge tapping, 1/8" GG Gauge tapping and 160psi (11 bar) gauge HP High pressure range 75- 125psi (5.27 — 8.79 bar) LP Low pressure range 10 -35psi (69 — 241 kPa) Z7 400psi (28 bar) initial pressure, 12" (20mm) models only Add Prefix LF Lead Freer construction tThe combined metal components of this product contacted by potable water contain Tess than one half of one percent (0.5 %) of lead by weight. Noryl® is a registered trademark of General Electric Company. Teflon® is a registered trademark of E.I. Dupont de Nemours & Company. Dimensions — Weights EP A - 25AUB-Z3 Al - 25AUB -S -Z3 A2- 25AUB- DU -LF -Z3 B - 25AUB -DU -Z3 B1 - 25AUB- S -DU -Z3 B2 - 25AUB- DU- THDxPEX -Z3 ET - NPT Engagement for tight joint Es - Female sweat socket depth EP - PEX end connection Standards 0 OD Meets requirements of ASSE Standard 1003: (ANSI A112.26.2: CSA Standard B356; Southern Standard Plumbing Code and listed by IAPMO. Military Standard MIL- V- 18146B Type I. Capacity Reduced Pressure Drop kPa psi 0 0 34 5 103 15 138 20 172 25 Sizes: 1/2 ", 3/4 ", 1", 11/4 ", 11/2" 2" • (15, 20, 25, 32, 40, 50mm) W W 1W 1'k 2 0 10 20 0 38 76 30 40 114 152 50 190 Flow 60 70 80 228 266 304 90 100 gpm 342 3801pm in SIZE (DN) mm in A mm in Al mm in DIMENSIONS k mm in B mm in B1 mm in 82 mm P' /z 15 51/4 137 55/%6 135 53/6 132 67/16 164 6%s 162 — — 3/4 20 55/6 135 51/2 140 51/4 133 61/2 165 67/6 175 63/4 171 1 25 6 152 61/4 159 5% 149 73%6 187 713/54 198 711A6 195 11/4 32 8% 222 815/6 227 81/4 210 10% 273 11 279 — — 11/2 40 8% 222 9 229 81/4 210 103% 273 113/6 284 — — 2 50 93/4 235 10 254 8% 222 115/6 287 12 1/6 322 — — in.' C mm D in mm in F * mm in DIMENSIONS G mm - ET in mm Es in mm EP in mm lbs. WEIGHT kg. 7 178 11/2 38 92/6 240 31/2 79 h 13 ' . 13 — — 3.5 1.6 7 178 11 38 9%6 240 31/2 79 1/2 13 3/4 19 % 16 3.5 1.6 8 203 1% 44 10'/6 266 35/6 92 5/B 16 15/6 23 13/6 21 6.5 3.0 9 229 21/2 54 117/6 291 3% 92 5/6 16 1 25 — — 10 4.5 9' 241 21/4 60 1115/6 304 41/6 103 5/B 16 1'/6 28 — — 10 4.5 111/4 286 31/4 83 131 %6 348 43/4 121 5/B 16 15/6 34 — — 15 6.8 * Dimension includes optional gauge ES -25AUB 0530 100 WATTS® !MT.?' !+ REGULATOR USA: 815 Chestnut St., No. Andover, MA 01845 -6098; www.wattsreg.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca © Watts Regulator Company, 2005 ES -009 Job Name Contractor Job Location FILE C PY Approval IEVVED FOR CODE COMPLIANCE D Engineer Contractor's P.O. No Approval Pef9t No. Representative P! Series 009 Reduced Pressure Zone Assemblies Sizes: 1/4" - 3" (8 - 80mm) Series 009 Reduced Pressure Zone Assemblies are designed to protect potable water supplies in accordance with national plumbing codes and water authority requirements. This series can be used in a variety of installations, including the preven- tion of health hazard cross connections in piping systems or for containment at the service line entrance. This series features two in -line, independent check valves, captured springs and replaceable check seats with an inter- mediate relief valve. Its compact modular design facilitates easy maintenance and assembly access. Sizes 1/4" - 1" (8 - 25mm) shutoffs have tee handles. Features • Single access cover and modular check construction for ease of maintenance • Top entry - all internals immediately accessible • Captured springs for safe maintenance • Internal relief valve for reduced installation clearances • Replaceable seats for economical repair • Bronze body construction for durability 1/4' - 2" (8 - 50mm) • Fused epoxy coated cast iron body 2W and 3" (65 and 80mm) • Ball valve test cocks — screwdriver slotted '/4° - 2" (8 - 50mm) • Large body passages provides low pressure drop • Compact, space saving design • No special tools required for servicing Specifications A Reduced Pressure Zone Assembly shall be installed at each potential health hazard location to prevent backflow due to backsiphonage and /or backpressure. The assembly shall consist of an internal pressure differential relief valve located in a zone between two positive seating check modules with captured springs and silicone seat discs. Seats and seat discs shall be replaceable in both check modules and the relief valve. There shall be no threads or screws in the water- way exposed to line fluids. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seat- ed isolation valves, four resilient seated test cocks and an air gap drain fitting. The assembly shall meet the requirements of: USC Manual 8th Editiont; ASSE Std. 1013; AWWA Std. C511; CSA B64.4. Shall be a Watts Regulator Co. Series 009. tDoes not indicate approval status. Refer to Page 2 for approved sizes & models. 2012 City of Tukwila BUILDING DIVISION 1/2" (15mm) 009QT Test Cock No 3 Ball Type Test Cocks Test Cock No 2 First Check Module Assembly R.P. Zone 2" (50mm) 009M2QTHC Test Cock No. 4 —1,11i77Lorc2ri �� l�rl Relief Valve Assembly 31'e Now valabl A w i�, sr*? bit; .:, WattsBox *Insulated' Enclosures. A h For more°informattion; send for literature'ES =WB > Second Check Module Assembly Water Outlet IMPORTANT INQUIRE WITH GOVERNING AUTHORITIES FOR LOC4L INSTALLATION REQUIREMENTS RECEIVED 1 FEB 07 2012 0 �- ERMIT CENTER Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise , or marshals with- AUIUUIU!S® please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Available Models: 1/4" - 2" (8 - 50mm) Suffix: QT - quarter -turn ball valves S - bronze strainer LF - without shutoff valves AQT - elbow fittings for 360° rotation 3/4" - 2° (20 - 50mm) only PC - internal Polymer Coating LH - locking handle ball valves (open position) SH - stainless steel ball valve handles HC - 21/2" inlet/outlet fire hydrant fitting (2° valve) Prefix: C - clean and check strainer 3/4° - 1' (20 - 25mm) only U - union connections (see ES-U009) Available Models: 21/2" - 3" (65 - 80mm) Suffix: NRS - non - rising stem resilient seated gate valves OSY - UL/FM outside stem and yoke resilient seated gate valves S -FDA - FDA epoxy coated strainer QT -FDA - FDA epoxy coated quarter -turn ball valve shutoffs LF - without shutoff valves S - cast iron strainer Note: The installation of a drain line is recommended. When installing a drain line, an air gap is necessary (see ES -AG). Materials: 1/4" - 2" (8 - 50mm) Bronze body construction, silicone rubber disc material in the first and second check plus the relief valve. Replaceable polymer check seats for first and second checks. Removable stainless steel relief valve seat. Stainless steel cover bolts. Standardly furnished with NPT body connections. For option- al bronze union inlet and outlet connections, specify prefix U (' /z° - 2 °(15 - 50mm)). Series 009QT furnished with quarter turn, full port, resilient seated, bronze ball valve shutoffs. Air Gaps and Elbows Materials: 21/2" and 3" (65 - 80mm) • (FDA approved) Epoxy coated cast iron unibody with bronze seats • • Relief valve with stainless steel seat and trim • Bronze body ball valve test cocks Pressure / Temperature Series 009 1/4" - 2" (8 - 50mm) Suitable for supply pressure up to 175psi (12 bar). Water temperature: 33 °F - 180 °F (0.5 °C - 75 °C). Sizes 21/2" and 3" (65 and 80mm) are suitable for supply pressures up to 175psi (12.1 bar) and water temperature at 110°F (43 °C) continuous, 140 °F (60 °C) intermittent. Standards USC Manual 8th Editiont ASSE No. 1013 AWWA 0511 -92 CSA B64.4 IAPMO File No. 1563. tDoes not indicate approval status. See below for approved models. Approvals ASSE, AWWA, CSA, IAPMO Approved by the Foundation for Cross - Connection Control and Hydraulic Research at the University of Southern California. Approval models QT, AQT, PC, NRS, OSY.` UL Classified 3/4" - 2" (20 - 50mm) (LF models only except 009M3LF) 21/2° and 3" (65 and 80mm) with OSY gate valves. MODEL for 909, 009 and 993 sizes DRAIN OUTLET W in. mm in. DIMENSIONS A mm in. B mm WEIGHT lbs. kgs. 909AG -A Y4" -1/2" 009, 1/2 13 2% 60 31e 79 .625 .28 3/4" 009M2/M3 909AG -C 3/4 " -1" 009/909, 1 25 3Y4 83 4% 124 1.50 .68 1"-11/2" 009M2 909AG -F 11/4" -2" 009M1, 2 51 4% 111 63/4 171 3.25 1.47 11/4"-3" 009/909, 2" 009M2, 4 " -6" 993 909AG -K 4 1_" 909, 3 76 6% 162 9% 243 6.25 2.83 8 " -10" 909M1 909AG -M 8 " -10" 909 4 102 73/e 187 11'/4 394 15.50 7.03 909EL -A 1/4 " -1/2" 009, 3/4" 009M2/M3 - - - - - - - - 909EL-C 3/4 " -1" 009/909. - - 23/e 60 2% 60 .38 .17 " 909EL -F 1W-2" 009M1, - - 35/8 92 3% 92 2 .91 11/4 " -2" 009/909, 2" 009M2. 4 " -6" 993 ' 909EL -H 21/2" -3" 009/909 - - - - - - - - Vertical A -- A B B Dimensions and Weight: 1/4" - 2" (8 - 50mm) 009 T N Suffix HC — Fire Hydrant Fittings dimension A' = 25° (637mm) 009 '/4" — 2" SIZE (DN) in. mm in. A mm in. 8 mm in. DIMENSIONS C mm (APPROX.) D in. mm in. L mm in. STRAINER DIMENSIONS M mm N in. mm WEIGHT Ibs. kg.s 1/4 8 10 250 45 /e 117 33/8 86 11/4 32 51/2 140 2% 60 21/2 64 5 2 3/e 10 10 250 45/4 117 33/8 86 11/4 32 51/2 140 2% 60 21/2 64 5 2 1/2 15 10 250 4% 117 33/8 86 1'/4 32 51/2 140 23/4 70 21/4 57 5 , 2 1/4 20 103/4 273 5 127 31/2 89 11/2 38 6% 171 33/16 81 23/4 70 6 3 1 25 16% 425 51/2 140 3 76 21/2 64 91/2 241 33/4 95 3 76 12 5 11/4 32 173/8 441 6 150 31/2 89 21/2 64 113/8 289 4'/16 113 31/2 89 15 6 11/2 40 17% 454 6 150 31/2 .89 21/2 64 11'% 283 4% 124 4 102 16 7 2 50 213/4 543 73/4 197 41/2 114 31/4 83 131/2 343 515/6 151 5 127 30 13 Dimensions and Weight: 21/211 and 3" (65 and 80mm) 009 STRAINER SIZE in. mm DIMENSIONS (appro .) M N Nit in. mm in. mm in. mm WEIGHT Ibs. kgs. 28 12.7 2'/z 65 10 254 6'/2 165 93/4 248 3 80 10' /a 257 tClearance for servicing 7 178 10 254 34 15.4 Watts G -4000 Series QT - Ball Valves MODEL SIZE DN in. mm in. A mm in. C mm in. DMENSIONS D mm (APPROX.) E in. mm in. L mm in. R mm in. U mm WEIGHT lbs. kgs. 009LF 21/2 65 — — — — 41/2 114 — — 18'% 460 — — 10% 270 76 34.5 0090SY 2' 65 331/4 845 15% 403 41/2 114 16% 416 181/4 460 7% 197 10%4 270 166 75.3 009NRS 21/2 65 331/4 845 11% 289 41/2 114 163 416 181/4 460 73/4 197 10% 270 161 73.0 0090T 212 65 331/4 845 6 152 4' 114 16% 416 181/2 460 7% 197 10%i 270 150 68.0 009LF 3 80 — — — — 41/2 114 — — 181/4 460 — — 10% 270 76 34.5 0090SY 3 80 341/4 870 1812 470 412 114 16% 422 181/2 460 83/4 222 10% 270 198 89.8 009NRS 3 80 341/4 870 12% 324 41/2 114 16%4 422 18% 460 83/4 222 10% 270 191 86.6 0090T 3 80 341/4 870 7 178 412 114 16% 422 18'%4 460 8% 222 10% 270 158 71.7 Capacity Performance as established by an independent testing laboratory. *Typical maximum system flow rate (7.5 feet/sec., 2.3 meters /sec.) kPa psi 138 20 117 17 96 14 76 1 55 8 35 5 ' /a" (8mm) 009QT AP O kPa psi 138 20 117 17 96 14 76 11 55 8 35 5 .25 .60 .75 1 1.17 gpm .95 1.9 2.9 3.8 4.5 Ipm 3" (10mm) 009QT 0 .25 .50 .75 1.25 1.50 2.5 aP 0 .95 1.9 2.9 3 8 4.8 5.7 9.4 11.8 Ipm 3.1 gpm kPa psi 172 25 138 20 103 15 69 10 35 5 v 1" (*5mm) 009QT 0 2.5 5 7.5 10 12.5 15 gpm oP 0 3 8 9 5 19 28.5 38 47.5 57 Ipm 5 7.5 15 fps 1.5 2.3 4.6 mps kPa psi 207 30 165 24 124 18 83 12 41 6 0 0 0 2 6 10 14 18 22 26 30 34 38 42 46 gpm oP 07.6 23 38 53 68 84 99 114 129 144 160175 Ipm 7.5 15 fps 2.3 4.6 mps 1 "1,(25mm) 009M2QT *3/4 ' (20mm) 009M3QT ■ ■ ■ ■ ■MIMMEME ■ ■ ■ ■ ■...... ■ ■ ■ ■ ■■II ■N••M ■■ ■ ■ ■..■■MR ■ ■ ■ ■ ■ ■I■■■MMEN■ ■I•■M■OIi■ ■ ■ ■ ■ ■ ■MENNI■MM■MMEWM:d■■ ■umu■ ■Iu ■ ■■■ms!MiMMEMME■ mmommI u ■ ■•■••m•••u■.u■■ ■.... I ilimm .min ••.•■ ■..ommilimmomu•• ■m■■■ ■• ■ ■m■mmmmmmmmmm ■•■ ■•■ kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 0 0 5 10 20 30 40 50 60 70 80 gpm 19 38 76 114 152 190 228 266 304 Ipm 7.5 15 fps 2.3 4.6 mps WWATrS® kPa psi 172 25 138 20 103 15 69 10 35 5 0 0 11/4" (32mm) 009M2QT AP kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 10 20 30 40 50 60 70 80 gpm 38 76 1 4 152 190 228 266 304 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 11/2" (40mm) 009M2QT 0 10 20 30 40 50 60 70 80 90 100 1 0 120 gpm ill" 0 38 76 1 4 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 AP 0 2" (50mm) 009M2QT kPa psi 172 25 138 20 103 15 69 10 35 5 0 0 AP0 20 40 60 80 100 120 140 160 180 200 gpm 76 152 228 304 380 456 532 608 684 760 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 21" (65mm) 009 kPa psi 172 25 138 20 103 15 69 10 35 5 0 0 0 25 50 75 100 125 150 175 200 225 250 275 300 325 gpm AP 0 95 190 285 380 475 570 665 760 855 950 104511401235 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps 25 50 75 100 125 150 175 200 225 250 gpm 05 10- 295 380 475 570 665 760 885 950 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 3" (80mm) 009 =9001 -2000 CERTIFIED A Watts Water Technologies Company ES -009 0830 USA: 815 Chestnut St., No. Andover, MA 01845 -6098; www.watts.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca © 2009 Watts BULB WELL FOR TEMP SENSOR -`` Rkilp CV PRESSU AIR PURGER DI-px R4e- ONION AUTOMATIC AIR VENT PRESSURE P.REDUCING ,. VALVE-\ '4 , v5 f" .4 alb" 4 • • 1; • • S 1-414X. —Y2" TO 1: FLOOR DRAIN L.., et.C12. G PIA , . FULL SIZE TO DRAIN ( — ------ EXPANSION TANK , - - '''. 0 \ '.--- ...... -7 —"" ••-■ i \-THERMOSTAT \-, 0 1 HT-(5- 1' I Ak W CW MAKE-UP FROM t REDUCED PRESSURE BACKFLOW PREVENTER, ei - - 1 H 1— 0 Tel fooN" -e7 2, EyoS,1":1,L)AAPS P !PEE) CHEMICAL P&T RELIEF VALVE DIRT LEG SUPPLIED BY 6a.c.i.ci,5„,,.ZOT FE E DIEF,%/Le j BOILER MFR ell?--V 4 15 ,le.(.>;-.-e_if io-f_RA BOLT BOILER TO PAD (4 PLACES) PIPE FULL SIZE NOTE: 1 TO DRAIN IN LOW TEMP INSTALLATIONS, SUCH AS HYDRONIC HEAT PUMP SYSTEMS, FOLLOW MANUFACTURERS 4" HOUSEKEEPING PAD RECOMMENDATIONS FOR PIPING, TEMPERATURE FLOW REQUIREMENTS FOR THE BOILER 1 HEATING. ..WATER PIPING SCHEMATIC 1 1 -0 NO SCALE 2-( C c, ....rk-t"1/4 V P e c A e., DETAIL TITLE: HEATING WATER PIPING SCHEMATIC CAD FILE NAME: P:\ CAD\ R15\ Standards\ Details\ Design\ Fitting\ F1 1 System Diagrams\ F1 1 —03.dwg DATE CREATED: DISCIPUNE USED FOR * MECHANICAL PIPING SCALE: NTS NO REVISIONS REVIEWED FOR DATE LAST REVISED: CODE COMPLIANCIE0.I.T REVISED SY: DESCRIPTION OF LAST REVISION: APPROVED FEB 2 3 2012 COMMENTS: City Tukwila DATE: 1 COMMENT: of BUB DING DIVISION RECEIVED L FEB 07 2012 1 ....., PERMITCENTER 1 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG12 -018 DATE: 02 -07 -12 PROJECT NAME: SOUTHCENTER MALL SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: spa Pcvici uilding Division uIi� E �-, Work �� Fire Prevention Structural Planning Division ❑ Permit Coordinator n r DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 02 -09-12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route LbJ Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 03 -08 -12 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with L£rI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information ' Name MACDONALD /MILLER FAC SOL INC UBI No. 602254260 Phone 2067684180 Status Active Address Po Box 47983 License No. MACDOFS980RU Suite /Apt. City Seattle State WA Zip 98106 County King Business Type Corporation Parent Company License Type Construction Contractor Effective Date 12/31/2002 Expiration Date 12/31/2012 Suspend Date Specialty 1 General Specialty 2 Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVCOI *988RC DIVCO INCORPORATION Construction Contractor General Unused 12/3/2002 11/7/2012 Active LINFOAR980QG LINFORD AIR a REFRIGERTN INC Construction Contractor General Unused 11/7/2002 11/7/2004 Archived ENCOMMS984CA ENCOMPASS MECHANICAL SERVICES Construction Contractor General Unused 2/1/2002 2/1/2004 Archived MACDOMR026RU MACDONALD MILLER RSDNTL INC Construction Contractor General Unused 12/31/1998 12/31/2001 Archived DIVCOI*031L4 DIVCO INC Construction Contractor General Unused 6/24/1997 8/1/2003 Archived MACDOMR0760P MACDONALD MILLER RESIDENTIAL Construction Contractor General Unused 9/17/1993 12/30/1998 Archived DIVCOEC188LC DIVCO ENERGY CONTROL COMPANY Construction Contractor General Unused 6/3/1982 5/26/1997 Archived MACDOM *248J9 MACDONALD MILLER CO Construction Contractor General Unused 4/29/1976 2/1/2002 Archived Business Owner Information Name Role Effective Date Expiration Date GOUGH, DAVID ANTHONY Director 12/29/2010 HOEL, STEPHANIE W Member 05/14/2010 SIMONDS, DERRICK R President 05/14/2010 WEBSTER, MARK E Vice President 05/14/2010 https://fortress.wa.gov/lni/bbip/Print. aspx 02/24/2012