Loading...
HomeMy WebLinkAboutPermit PG12-094 - PINK A BELLAPINK A BELLA 1002 SOUTHCENTER MALL PG1 2-094 City AiI'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov PLUMBING /GAS PIPING PERMIT Parcel No.: 9202470010 Address: 1002 SOUTHCENTER MALL TUKW Project Name: PINK A BELLA Permit Number: Issue Date: Permit Expires On: PG 12 -094 05/17/2012 11/13/2012 Owner: Name: Address: Contact Person: Name: Address: Email: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 BRAD WILLIAMS 3903 SMITH AV , EVERETT WA 98201 BRAD @ W ILLIAM S -M E C HANI C AL. C O M Contractor: Name: WILLIAMS MECHANICAL INC Address: 3903 SMITH AV , EVERETT WA 98201 -4549 Contractor License No: WILLIMI088PA Phone: 425- 303 -0828 Phone: 425 303 -0828 Expiration Date: 10/01/2013 DESCRIPTION OF WORK: ROUGH -IN AND INSTALL PLUMBING FOR NEW HANDSINK Value of Plumbing /Gas Piping: Fees Collected: Electrical Service Provided by: Permit Center Authorized Signature: $2,500.00 Uniform Plumbing Code Edition: 2009 $137.81 International Fuel Gas Code Edition: 2009 Date: as/ /a/ l� I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions on the back of this permit. Print Name: 1/K- . t1 V / Date: 5. -17 -12 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG12 -094 Printed: 05 -17 -2012 PERMIT CONDITIONS Permit No. PG 12 -094 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments. 13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG12 -094 Printed: 05 -17 -2012 CITY OF TUKWI Community DevelopmetWepartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup: / /www.TukwilaWA.gov PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: / 6O1- LL Tenant Name: King Co Assessor's Tax No.: Suite Number: J \46k Floor: ,`PROPERTY'OWIVE {, ' j; ... $.: ,' j' 4p . "_ Name: U3C¢A- _�Q Address:) tGo l 1► W v ` ricw, City:t63 State ZiqCtoaS . ae 1s i »_ r -- c� - a:.i t,,,.w + ti 4 �r+s �.� ..� s s CONTACT�PERSON personYreceiving all :protect,' k, .•communicationyi `,..... 4 -; 1; `... -. ,, UcL; l�,•, Name: Q n s , . -Q \ ` ptiv� s y ` Address: S o; +A , e. \ clA City: State: , Z' •Atig 0 Phone:4 30? og Z ax :4 7 sg9 _cr2.4ei Email: - Y7v-t i ).n1'. ISMS— Mecrtcllnt cp.. 'CO New Tenant: ❑ Yes /Er... No PLUMBING CONTRACTOR INFORMATION ' ' `r Company Name: /� �` S . A ,t e tAt ,\, (C ( m Address: 1 0 3 ` sAA t rbk tc\II City . State: V44 Zi jm ''��'' oo241_, 1 Phone �s, Fax11 � ce ( Contr Reg No.JLjM Q i Exp Date/&t (l3 Tukwila Business License No.: 0)60 S9 (4_ • Wur _ •, •., .v�:�w1+J' ' .•• \'WLSv, •• .•'•..• ^.•^�—• ,•"oL�+/,- .�v-S^ •a�Y- -iaV��.i= trz -thVa ^±a�°xY_!Nawr Valuation of Project (contractor's bid price): $ Sco a of Work (please provide detailed information): 2sa�b�-1 ►'�l �U � S'\ y, Building Use (per Int'1 Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water: Sewer: .H:Wpphcations\Forms- Applications On Line \2011 Applications\Plumbing Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or s piping outlets being installed and the quanti ' elow: Fixture,Type Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen ( >750 gallon capacity) Each additional medical gas inlets /outlets greater than 5 ' Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Fixture Type r •` Qty`', Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT ;APPLICA= TION,NOTES • s a. . w.. .. ,: ..•6 .&., 't ;. � ,.....i5�.t..4y:.�.F;Klw..ryC..L -J:�Y „< Fixture Type ,. :,, ..1.- Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets �' ..Fixture.Type •-Qty`' Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value'of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 0 h! TH'1 ' / r Tfi AIF BUILD Signatur Print Name: Mailing Address: LA U_A-kAAS 114. II le H:Wpplications\Forms- Applications On Line \2011 Applications\Plumbing Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Date: Z 'f l (Z Day Telephone:2� S O 2$ State Zip City .: Page 2 of 2 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: PG 12 -094 Address: 1002 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/11/2012 Applicant: PINK A BELLA Issue Date: Receipt No.: R12 -01560 Payment Amount: $137.81 Initials: WER Payment Date: 05/11/2012 12:02 PM User ID: 1655 Balance: $0.00 Payee: BRADLEY WILLIAMS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 036756 ACCOUNT ITEM LIST: Description 137.81 Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000.345.830 27.56 000.322.103.00.00 110.25 Total: $137.81 doc: Receiot -06 Printed: 05 -11 -2012 INSPECTION RECORD 4,16 'Q 4:174 Retain a copy with permit t INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 vz, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project. t� g �� / 4 Type QI'-Inspecti n p( Address: i 062- sue-.. MA/ Date C d: l�—c� !-� G Special Instructions: Date Wanted: Requester: Phone No: �6. ........41 1t _i6 570 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: JkuW'o(. tl A Inspecto Date: (_ f4 ( ' � REINSPECTION FEE REQUIRED rior to next inspection. fee must be . paid at 6300 Southcenter Blvd., uite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO.' CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431-2451 P 'z -o95' Project: PA// ',4 ;3e Type of Inspection: /) (3)/4 / r — v 7.t iii 4j Address: - • /(2(22 • S4(iAL /?7q r/ Date Called: Special Instructions: Date Wanted:. a.m. Requester: Phone No: 6t — 47/9/ —i6` O aApproved per applicable codes. Corrections required prior to approval. COMMENTS: / &4t - App /41✓-eZ n } L, is 012-1Q . '5-WA& c7 /94/1/K 1-1,,f — A/f i i Inspect • r: Date: /9 - /Z- REINSPECTION FEE R QUIRED. Pr }r to next inspection. fee must be paid at 6300.Southcent r Blvd., Suite 100. Call to schedule reinspection. • PENT CO y • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG12 -094 DATE: 05 -11 -12 PROJECT NAME: PINK A BELLA SITE ADDRESS: 1002 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued t. DEP RTMENTS: uil ing Divisi n P�ttillc Works Structural Fire Prevention Planning Division n ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 05-15-12 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: DUE DATE: 06 -12 -12 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 IA King County Department of Natural Resources and Parks Wastewater Treatment Division Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type y(*.- 06/123 1002_ S u e� -- Property Street Address ° IC—W∎Lfdt• Wfk" 6‘SC6 City State ZIP Owner's Name Subdivision Name Subdiv. # Lot # Block # Building Name (if applicable) Owner's Phone Number (with Area Code) Property Contact Phone Number (with Area Code) Owner's Mailing Address For King County Use Only Account # No. of RCEs Monthly Rate Property Tax ID # Party to be Billed (if different from owner) City or Sewer District Date of Connection Side Sewer Permit # Please report any demolitions of pre - existing building on this property. Credit for a demolition may be given under�soe circumstances. Demolition of pre- existing building? ❑ Yes R1Vo Was building on Sanitary Sewer? ees ❑ No Was Sewer connected before 2/1/90? es ❑ No Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? ❑ Yes ❑ No A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 ' Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 Water closet, tank or valve, >1.6 GPF 8 4 Total Fxture Units L j Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units 20 RCE B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) _ 187 C. Total Residential Customer Equivalents: (add A & B) A B .d5 RCE RCE RECEIVED MAY 112012 PERMIT CENTER Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is corre deviation will require resubmission tand tha the c for de acity charge levied will be based on this information and any on of a rev.sed capacity charge. Date SI 11) Signature of Owner /Representative Print Name of Owner /Representativ nsu (Fla, o /n71 White — Kinn County Yellow — Local Sewer Anencv Pink — Sewer Customer (Z Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name WILLIAMS MECHANICAL INC UBI No. 601413863 Phone 4253030828 Status Active Address 3903 Smith Ave License No. WILLIMI088PA Suite /Apt. License Type Construction Contractor City Everett Effective Date 10/1/1992 State WA Expiration Date 10/1/2013 Zip 982014549 Suspend Date County Snohomish Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WILLIPH136Q4PLUMBING WILLIAMS & HTG INC Construction Contractor Boiler /Steam Fit /Prot Piping Plumbing 11/24/1987 11/19/1992 Archived Business Owner Information Name Role Effective Date Expiration Date WILLIAMS, DEBORAH KAY Agent 09/27/2011 Bond Amount WILLIAMS, BRADLEY PATRICK President 01/01/1980 1977877 WILLIAMS, DEBORAH KAY Secretary 01/01/1980 WILLIAMS, DEBORAH KAY Treasurer 09/27/2011 INS CO OF THE WEST ZUCCARINI, MICHAEL J Agent 01/01/1980 01/01/1980 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 THE HANOVER INS. 1977877 10/01/2010 Until Cancelled $12,000.00 09/15 /2010 3 INS CO OF THE WEST 2271807 10/01/2007 Until Cancelled 10/23/2010 $12,000.0010/01 /2007 2 CBIC 634038 09/30/2001 10/01/2007 09/30/2007 $6,000.0009/25/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 17 CHARTER OAK FIRE INSURANCE COM 4TC00427P552C0F0909/30/2010 09/30/2012 $1,000,000.0009 /13/2011 16 CONTINENTAL WESTERN INSURANCE CWP2643064 09/30/2007 09/30/2010 $1,000,000.00 09/23/2009 15 CONTINENTAL WESTERN INS CO CWP2643064 09/30/2006 09/30/2007 $1,000,000.0009 /26/2006 14 WEST AMERICAN INS CO BK053242160 09/30/2004 09/30/2007 $1,000,000.0009 /18/2006 https://fortress.wa.gov/lni/bbip/Print.aspx 05/17/2012 A1.0 S M SA:1122.03.06 L (E) MALL CONCOURSE (E) FLOOR CLEAN OUT WASTE LINE. FIELD VERIFY LOCATION. DEMO FLOOR PLAN 1/2" = 1' -0" (E)13tULKI -SAO 'FINS' TO EE DEMOLISHED TO BE ITS ENTIRETY, IXTURES, ETC. PHOTO DETAIL N.T.S. Provide Hand Sink with Insta hot water heater & tempering valve for hot water at fixture 12" Waste to new Hand Sink, 2" I VTR,1l2" cold water down 2' -0" 1/2" Cold Water 1l2" cold Water to tie to existing contractor to verify exact location New 2" waste to tie to existing Waste system at 4" Clean Out Contractor to verify exact Loctalon 10' -®" 12'-0" NORTH FLOOR PLAN 1/2" = 1' -0" option 2 PATCH/REPAIR AND PREP (E) GU B TO LEVEL" 4 FINISH - ADJACENT TENANT STOREFRONT To REMAIN _ (E) WALL ASSEMBLY RE: WALL TYPE TENANT LEASE LINE (E) TiLE BASE LE ) ADJACENT TO REMAIN STOREFRONT TO REMAN NEUTRAL PIER DETAIL 1 1/2" = 1' -0" TENANT LEASE LINE " ALUMINUM REVEAL (E) WALL ASSEMBLY RE: WALL TYPE METAL STUD AND GWB FRAMING RE: WALL TYPE NEUTRAL PIER DETAIL 1 1/2" = DEMOLITION GENERAL NOTES: L ALL REASONABLE EFFORT HAS BEEN MADE BY THE DESIGN TEAM TO REPRESENT EXISTING CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF EXISTING ITEMS, NCLUDNG BUT NOT LIMITED TO, FLOORING, CEILING, WALL ASSEMBLY, WALL FINISHES, ETC. IN EFFORT TO PREPARE SPACE FOR NEW CONSTRUCTION. 2. ALL ELECTRICAL, PLUMBING, AND MECHANICAL SYSTEM WITHIN THE AREA OF DEMOLITION SHALL BE DEMOLISHED M THEIR ENTIRETY AND CAPPED AT. THEIR RESPECTIVE POINT OF ORIGIN. FLOOR PLAN GENERAL NOTES: 1. DMENSION PROVIDED ARE PLUS/MINUS DIMENSION TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSION AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. PATAJELECTRICALAIECHANICAL ARE SHOWN FOR REFERENCE ONLY. DATA, ELECTRICAL, AND MECHANICAL DESIGN SHALL SE SUBMITTED BY CONTRACTOR AND PERMITTED UNDER SEPARATE PERMIT. 3. ALL MATERIALS SHALL BE NON - COMBUSTIBLE AND /OR SHALL COMPLY WITH THE REQUIRED FLAME SPREAD OR SMOKE DEVELOPED INDEX FOR TYPE II CONTRUCt10N. ALSO ANY woo COMPONENTS USED SHALL BE FIRE RETARDANT TREATED WOOD. (IBC 402.15.4, 602, 603, 4 2604) 4. CONTRACTOR SHALL VERIFY EXISTING CONDITION AS WELL AS LEASE LIDS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF WESTFiELD FOR CLARIFICATION. 5. CONTRACTOR SHALL PROTECT MALL COMMON AREA At ALL TIMES AND NO CONSTRUCTION MATERIAL, DEBRIS, WORK, OR DUST SHALL ENTER OR BE WITHIN MALL COMMON AREA. 6. CONTRACTOR SHALL PRIME ALL NEWLY CONSTRUCTED WALLS, NEUTRAL PIERS, SOFFITS, AND BULKHEADS TO LEVEL 4 FINISH. NEUTRAL PiER AND MALL CONCOURSE AREAS TO EE PAINTED TO LEVEL 4 FINISH. 1. AREAS DESIGNATED AS 'NO WORK THIS AREA' SHALL REMAIN AS CURRENT CONDITION. THE SPACE SHALL MEET THE REQUIREMENTS SET FORTH BY LOCAL JURISDICTION FOR A VACANT SPACE. SPRINKLER SYSTEM AND FiRE ALAR1 SHALL PROVIDE COVERAGE FOR THE VACANT SPACE AND NEW LANDLORD STORAGE AREA AS REQUIRED. S. CONTRACTOR SHALL CAP AND TERMINATE ALL EXISTING UTILITIES AND SERVICES DESIGNATED TO BE DEMOLISHED, AT FINISH FLOOR LEVEL FOR ALL SERVICES MD UTILITIES WITHIN THE FLOOR 81.AB. 9. CONTRACTOR SHALL CAP AND TERMINATE ALL EXISTING UTILITIES AND SERVICES DESIGNATED TO BE DEMOLISHED ABOVE FINISH FLOOR LEVEL AT ITS POINT Of ORIGIN. 10. CONTRACTOR SHALL FURNISH AND INSTALL FIRE ALARM, SMOKE DETECTORS, AND SPRINKLERS AS REQUIRED BY LOCAL JURISDICTION HAVING AUTHORITY. 11 CONTRACTOR SHALL PROVIDE REQUIRED MECHANICAL (I4VAC) AND ELECTRICAL SERVICE TO AREA UNDER SEPARATE PERMIT. deMP GO WALL TYPES WALL TYPE GENERAL NOTES: itt4LL TYPE - EXISTING (1 -14R RATED) UL DESIGN • LI-465 - (E) 5/8" TYPE X GWB - (E) 6" METAL STD FRAMING - (E) 5/8" TYPE X GWB AT TENANT SPACE - WALL SHALL CONTINUE UP TO STRUCTURE W/ GWB STOPPING 6" FROM STRUCTURE NOTES: L CONTRACTOR SMALL VERIFY THE STATUS OF EXISTING WALL ASSEMBLY TO MEET 1 -14R RATED ASSEMBLY REQUIREMENT. 2. CONTRACTOR SMALL PATCH AND REPAIR GIB AS REQUIRED t0 RECEIVE LEVEL 4 FINISH. 2 WALL TYPE - EXISTING (1 -HR RATED) UL DESIGN • U -465 - 5/8" TYPE X GWB - 6" METAL STUD FRAMING - 5/8" TYPE X GWB AT TENANT SPACE - WALL SHALL CONTINUE UP To STRUCTURE W/ GAB STOPPING 6" FROM STRUCTURE 3 WALL 1 rPE - INTERIOR PARTITION - 5/8" TYPE x GM - 3 5/8" METAL STUD FRAMING - 5/8" TYPE X GWB AT TENANT SPACE CONTINUE UP TO 6" ABOVE CEILING TILE AND GRID 1 CONTRACTOR SMALL VERIFY EXISTING CONDITION, INCLUDING BUT NOT LIMITED TO METAL STIR WIDTH AND THICKNESS, HEIGHT OF STUD FRAMING, CONDITION OF EXISTING GUS. 2. CONTRACTOR SHALL PREP AND PRiME ALL NEW TENANT SPACE GUJB AND STORAGE AREA GUS TO LEVEL 4 FINISH. 3. CONTRACTOR SHALL PREP AND PANT ALL MALL CONCOURSE (NEUTRAL PIERS, BULKHEAD, ETC., RELATED AREAS TO LEVEL 4 FINISH. COLOR TO BE DETERMINED BY WESTFIELD. 4. CONTRACTOR SMALL MAINTAIN RATING OF ALL 1 -HOUR RATED ASSEMBLIES - EXISTING AND NEW ASSEMBLIES - WITHN AREA OF WORK DEMO FLOOR PLAN KEY NOTES: OUTLINE OF AREA DESIGNATED TO BE DEMOLISHED BY CONTRACTOR N PREPARATION AND ACCESS FOR DEMOLITION C/FF WALL ASSEMBLY AND CONSTRUCTION OF NEW TENANT DEMISING WALL IT SHAL.1. BE THE CONTRACTOR'S RESPONSIBILITY TO DEMOLISH AND REMOVE ANY OBSTRUCTION THAT PREVENT DEMOLITION AND CONSTRUCTION ACTIVITY. WORK SHALL INCLUDE, BUT NOT BE LIMITED t0, WALLS, CASEWORK, COLT IN COVERS, FIXTURES, FLOORING, BASE, AND ALL FNISMES, AS REQUIRED FOR DEMOLITION AND CONSTRUCTION OF DESIGNATED WALL ASSEMBLY. (E) FLOOR FINISHES TO BE DEMOLISHED IN THEIR ENTIRETY, INCLUDING BUT NOT LIMITED TO, TILE, WOOD FLOOR, VCT, CARPET, ADHESIVES, GROUT, ETC. (E) MALL CONCOURSE TILE TO BE DEMOLISHED. (E) DISPLAY CASE TO BE DEMOLISHED 114 ITS ENTIRETY. (E) METAL STUD FRAMING AND GM WALL ASSEMBLY TO BE DEMOLISHED IN ITS ENTIRETY, FROM SLAB TO STRUCTURE. DEMOLITION OF WALL ASSEMBLY SHALL INCLUDE, BUT NOT BE LIMITED TO, S•'JP BOTTOM AND TOP TRACK, METAL STUD FRAMING, GUS, WALL FIXTURES, ELECTRICAL, DATA, AND MECHANICAL FIx URES/SERVICE5 (E) DOOR AND FRAME TO BE DEMOLISHED IN ITS ENTIRETY, INCLUDING BUT NOT LIMITED TO, DOOR, FRAME, HARDWARE, ETC. (E) TENANT DEMISING WALL TO REMAIN. CONTRACTOR SHALL PRIME AND PREP EXISTING GAB TO LEVEL 4 FINISH. FURNISH AND INSTALL WASTE LNE FROM EXISTING MALL WASTE LINE TO SAM OF TENANT SPACE. 8A1LICUT/1RENCH AND PATCH CONCRETE AS REQUIRED TO INSTALL WASTE LINE WITH REQUIRED SLOPE TO DRAIN AND CONNECT TO (E) LINE. STUB UP WITHIN TENANT SPACE AT 3 COMP SINK AND MOP SINK ® (E) GRAPHIC TO BE DEMOLISHED N ITS ENTIRETY. (E) MALL CONCOURSE TILE TO BE DEMOLISHED. FURNISH AND INSTALL TILE TO MATCH (E) MALL CONCOURSE TILE. r I SHADED AREA SHALL REPRESENT THAT AREA DESIGNATED TO BE DEMOLISHED 114 ORDER FOR CONSTRUCTION OF NEW DEMISING WALL DEMOLITION SHALL INCLUDE BUT NOT BE LIMITED TO WALLS, CO LIN COVERS, FIXTURES, FLOORING, BASE, AND ALL FNISMES ASSOCIATED WITHIN THE AREA OF DEMOLITION 114 PREPARATION OF 1 NEW CONSTRUCTION. FLOOR PLAN KEY NOTES: 01 FURNISH AND INSTALL WASTE LINE FROM EXISTING MALL WASTE LNE TO BACK OF TENANT SPACE. 5,4LUCUT/TRENC14 AND PATCH CONCRETE AS REQUIRED TO INSTALL WASTE LINE WiTH REQUIRED SLOPE TO DRAIN AND CONNECT TO (E) LINE. STUM UP WITHIN TENANT SPACE AT 3 COMP SINK AND MOP SINK MD PJ11JRE PREP SW. (E) TENANT DEMISING WALL TO REMAIN. CONTRACTOR SHALL PRIME AND PREP EXISTING GLLE TO LEVEL 4 FINISH. CONTRACTOR SHALL CLEAN, PREP AND PREPARE CONCRETE SLAB IN PREPARATION FOR FLOOR FINISHES BY TENANT. CONTRACTOR SHALL FURNISH AND INSTALL FLOOR TILE TO MATCH EXISTING CONCOURSE TILE 114 SIZE, SHAPE, AND THICKNESS. 3 COMP SINK FURNISHED AND INSTALLED BY CONTRACTOR MOP SINK FURNISHED AND INSTALLED BY CONTRACTOR. FUTURE EQUIPMENT LIST: FURNISHED BY CONTRACTOR, INSTALLED BY TENANT HAND SINK FREEZER Permit No. CO PREP SINK PI„» r nr ew approval is subject to errors and omissions. O HOT WATER HEATER 1•,; : _ ` 01 construction documents does not authorize O REFRIGERATOR t' , t"= n of any adopted code or ordinance. Receipt o L;iproved Field Copy and • nditions is acknowledged: O COLNTER AND SEATING O CASH REGISTER DISPLAY CASE B Date: 6"--( REVISIONS Flo changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOT :: R e.v ;sions will require a new plan submittal and may include additional plan review fees. /2— City Of lbkwila BUILDING DIVISION SEPARATE- PERMIT REQUIRED FOR: Mechanical Cj lectrical 1.1 Plumbing gitSs Piping "'3`y of Tukwila l.'i LEI.,n.)?,` G DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1a 2012 J-7 L City of Tukwila BUILDING DIVISION RECEIVED MAY 112012 PERMIT CENTER eStfieff Sou th cen ter 20"-2 e-o423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025-1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SEWAGE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECTS PERMISSION AND UNLESS 111E REPRODUCTION CARRIES THE ARCHITECTS NAME. ALL DESIGN AND OTHER INFORMATION SHOYM ON THE ORAIINO ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEAMS, WA 98106 (208) 824 -2777 • FAX (208) 624 -2973 4220 REGISTERED ARCHITECT WESTFIELD MALL AT SOUTHCENTER ISSUE ISSUE DATE: SCOTT M. STEMPER STATE OF WASHINGTON PERMIT SET MARCH 28, 2012 PROJECT ARCHITECT WEJ PROJECT MANAGER lAl DEMO PLAN, FLOOR PLAN, AND DETAILS