HomeMy WebLinkAboutPermit PG12-098 - SAHALE SNACKSSAHALE SNACKS 3411 S 120 PL PG1 2-098 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1023049069 Address: 3411 S 120 PL TUKW Project Name: SAHALE SNACKS PLUMBING /GAS PIPING PERMIT Permit Number: PG 12 -098 Issue Date: 05/25/2012 Permit Expires On: 11/21/2012 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA 98168 Contact Person: Name: BUD KLOSTERMAN Address: 8706 S 222 ST , KENT WA 98031 Email: BUD @STATEMECH.NET Contractor: Name: STATE MECHANICAL COMPANY Address: 600 INDUSTRY DR 8 , TUKWILA WA 98188 Contractor License No: STATEMC 141 C7 Phone: 206 -575 -7527 Phone: (206)575 -7527 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: ADD (2) SINKS ONE REROUTE TO EXISTING WATER HEATER Value of Plumbing /Gas Piping: Fees Collected: Electrical Service Provided by: Permit Center Authorized Signature: $6,400.00 $189.00 Uniform Plumbing Code Edition: 2009 International Fuel Gas Code Edition: 2009 Date: I hereby certify that I have read and examined t 's permi `• d know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether spec . ied herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions on the back of this permit. Signature: Print Name: SID2 S c e4 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG12 -098 Printed: 05 -25 -2012 PERMIT CONDITIONS Permit No. PG 12 -098 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG12 -098 Printed: 05 -25 -2012 CITY OF TUKWIN Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov • Plumbing/Gas Permit No. `'G I7._-'Q 7,0 Project No. Date Application Accepted; S -LS -l2 Date Application Expires: 1 ^� t (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: ..s.--3:\/L4 I ( S w L King Co Assessor's Tax No.: 1 O Z 30L1 c1 O ( q Suite Number: Floor: Tenant Name: 50■ (AIL- Mcks t - 2 New Tenant: ❑ Yes ❑ ..No PROPERTY OWNER Name: D 01) ( l.cX2M A N Name: SA- G EY co 2- e City: I/ _.� State: A Zipgg0 Address: I '2,2o 1 TOV-L., t LA (NT(-- a t_ Ub City: SE PrTTC.C— State: f (-j Zip: i(8( (o 8 CONTACT PERSON - person receiving all project communication Name: D 01) ( l.cX2M A N Address: g --�v CO 5 '2-1_,—/,° c Sr City: I/ _.� State: A Zipgg0 Phone_ 55 -7311F ax:2,0C, -575 7 51,9 Email: 19 v p. s j- (,yvQ_Cin . Y,42A PLUMBING CONTRACTOR INFORMATION Company Name: CJ r^ 0,16c u 40 t C Address: ic (Q(0 S -2:2:2,0 D s City: A/ _ y` State A Zip $03 j Phone:29(3 •-5-7; -7527 Fax: 7,0C2 _51c...752,1 Contr Reg No. srAte_ (Au Y icii Exp Date: a/ i /1.3 Tukwila Business License No.: 505_6 16 1 359 Valuation of Project (contractor's bid price): $ i q 00 Scope of Work (please provide detailed information): Z. 5.'(`l 6(&)z V vb,i tk. d ex:( 5-6 W ot4 v 14-12-61/4-Cy Building Use (per Int'l Building Code) - Occupancy (per Int'I Building Code): Utility Purveyor: Water H:WpplicmionsWorms- Applications On Lme12011 Applications\Pluntbmg Permit Application Revised 8- 9- 11.dooc Revised: August 2011 bh Sewer- Page 1 of 2 • • Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with indupcudentdrain ' Shower, single head trap Sinks 2 Rain water system — per drain (inside building) it Grease interceptor for commercial kitchen ( >750 gallon capacity) ( Each additional medical gas inlets/outlets greater than 5 l Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent it C LQ \oCP re) ( Repair or alteration of water piping and/or water treatment equipment l Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping ( Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT'APPLICATION NOTES = Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW OR A -MS>WED AGENT: Signature: Date: 5 - I ✓ - / 2 Print Name: 1 L' 0 V L CST Day Telephone: '%%fir —,515 -7527 Mailing Address: t dCD S 21- 1T W � 803 City State Zip H:\ Applications \Form - Applications On Lane \201 I Applicaztons\Plumbmg Pemut Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1023049069 Address: 3411 S 120 PL TUKW Suite No: Applicant: SAHALE SNACKS RECEIPT Permit Number: PG 12 -098 Status: PENDING Applied Date: 05/15/2012 Issue Date: Receipt No.: R12 -01590 Payment Amount: $189.00 Initials: WER Payment Date: 05/15/2012 01:08 PM User ID: 1655 Balance: $0.00 Payee: STATE MECHANICAL CO TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1543 189.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000.345.830 37.80 000.322.103.00.00 151.20 Total: $189.00 doc: Receiot -06 Printed: 05 -15 -2012 INSPECTION RECORD Retain a copy with permit. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 /2- 098 Project: _ 5%09/1,01.(C SAN C'« S Type of Inspection: P Ame. -i3/20-14rA Address: Date Called: Special Instructions: Date Wanted: Requester: Phone No: X5-3 .24 ‘.,-56ss Approved per applicable codes. D- Corrections required prior to approval. �6 COMMENTS: ' E SPECTION FEE REQUIR D. Prior tf next inspection. fee must be id at 6300 Southcenter Blvd. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO...: CITY OF TUKWILA' BUILDING DIVISION ,6300 Southcenter Blvd., #100, Tukwila. WA 98188 fa_ (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 /36 -041 PERMIT NO. Project: . i l-- I :SAJA-rfi-c Type of Inspection: �,) .� ‹ ti- z..w M.° ilAg Address: 4ti 71, 6'2-o-PCf- Date Called: 6r -OJA.0 or Special Instructions: Date Wanted:,,,. /(1:-1; m. Requester: P'hho%ne No: r q '7 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Insp ctor: ii Date ?� t� REINSPECTION FEE'EQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. TIE INTO EXISTING SAN FILE CrPY V2" VTR DW 2" SAN WASTE a VENT RISER DIAGRAM FOR LUNCHROOM @ SAHALE SNACKS SINK IIt INTO EXISTING VENT V2" VENj/ REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 3 2012 City of Tukwila BUILDING DIVISION TIE INTO EXISTING SAN RECEIVED MAY 152012 PERMIT CENTER WASTE a VENT RISER DIAGRAM FOR ROOM 103 @ SAHALE SNACKS T'G 1 Dci8 TIE INTO EXISTING CW &HW FILE COPY Permit No. HOT a COLD RISER DIAGRAM FOR LUNCHROOM @ SAHALE SNACKS SINK .DISH WASHER 3ecw / / �2"HW RECEIVED 3-comp MAY 15 TIE INTO .� SINK 2012 C M T EXISTING CW PERMIT ENTER &HW REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 3 2012 City of Tukwila BUILDING DIVISION HOT & COLD RISER DIAGRAM FOR ROOM 103 @ SAHALE SNACKS PERU CO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG12 -098 PROJECT NAME: SAHALE SNACKS SITE ADDRESS: 3411 S 120 PL, SUITE 100 X Original Plan Submittal Response to Incomplete Letter # DATE: 05 -15 -12 Response to Correction Letter # Revision # After Permit Issued EPART ENTS: C/ ing D visipn 1\ tit II Public Works Fire Prevention Structural Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05-17 -12 Complete Incomplete n Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route k Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06-14 -12 Approved n Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Deter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company STATE MECHANICAL COMPANY 2065757527 8706 S 222Nd St Kent WA 98031 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 600611697 Active STATEMC141C7 Construction Contractor 2/27/1986 9/1/2013 Plumbing Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DESIGM'110NQDESIGN MECHANICAL Construction Contractor Boiler /Steam Fit /Proc Piping plumbing 8/18/1989 8/17/1993 Archived RXHCO "121NARXH COMPANY Construction Contractor Plumbing g Boiler /Steam Fit /Proc Piping 8/1/1988 7/27/1999 Archived GERRICI163B3 GERRIK COMPANY INC Construction Contractor General Unused 1/23/1984 1/9/1991 Archived Business Owner Information Name Role Effective Date Expiration Date PLATZ, GREG D Cancel Date 01/01/1980 Amount DEWITT, RALPH E 22 01/01/1980 GL1650262 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 TRAVELERS CAS a SURETY CO 200686359 07/27/2001 Until Cancelled $6,000.00 08/14/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 22 Colony Ins Co GL1650262 06/02/2011 06/02/2012 $2,000,000.00 06/02/2011 21 COLONY INS CO GL1650262 06/02/2010 06/02/2011 $1,000,000.0009 /16/2010 20 COLONY INS CO GL1650261 06/02/2008 06/02/2011 $1,000,000.0005 /06/2010 19 FIRST MERCURY INS CO FMFL001801 06/02/2006 06/02/2008 $1,000,000.00 05/09/2007 18 NORTH AMERICAN CAPACITY PNG100046600 06/02/2006 06/02/2007 $1,000,000.00 05/25/2006 17 LEXINGTON INS CO 1143373 A 06/02/2004 06/02/2006 $1,000,000.00 05 /19/2005 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni /bbip /Print.aspx 05/25/2012 O I EXISTING STOREFRONT n no 0 z 0 w \/ FABRIC AWING WITH WELDED ALUMINUM FRAME AND 1 1/2" LACE RAIL SUNBRELLA COLOR: TRESCO CLAY, COVER AND (2) FITTED ENDS. BLACK PAINTED FRAMES EXISTING FRAMED INFILL EXISTING WALL PACK LIGHT FIXTURE BEYOND, WALL MOUNTED STOREFRONT UNDER SEPARATE PERMIT PERMIT D11 -383 S ELEVATION * ENTRY SCALE: 1/4" = 1' -0" 1 2' -0" SIDE ELEVATION AWNING Ir u;ED FOR: iirtiktbanical "lactrical 0 Plumbing as Piping i`. 7 of Tukwila " . :IN DIVISION n C � �I EXIT EXIT TR FRONT OFFICE 0 0 0 0 0 0 11-458 A0.1 (SITE PLAN).dwg E t. t. 0 a 0 a a a u 0 a AREA OF WORK 0 ANNEX OFFICE LUNCHROOM AREA OF WORK 4 TRAVEL DISTANCE: ..r-------- ■ ■ T DISTANCE: 96' -2" REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 3 2012 City of Tukwila BUILDING DIVISION ARCHITECTURAL SITE /EGRESS /WAREHOUSE PLAN 1" = 20' -0" REVISIONS r.'wm ,tns shall loo made to the scope rtithout prior approval of Building Division. will require a new plan submittal a y in:utie additional plan review fees. GENERAL NOTES: 1. ALL COLUMNS AND EXTERIOR WALLS ARE EXISTING TO REMAIN. 2. GC TO PROVIDE REQUIRED PORTABLE FIRE EXTINGUISHERS IN OCCUPANCIES AND LOCATIONS AS REQUIRED PER SECTION 906 IN THE INTERNATIONAL FIRE CODE. 3. STRUCTURAL REVIEW IS REQUIRED FOR ANY ROOF TOP EQUIPMENT OR ROOF PENETRATIONS. 4. SEE SHEET A2.1 FOR ROOM OCCUPANCY CALCULATIONS EGRESS SUMMARY A. MAX. TRAVEL DISTANCE B OCCUPANCY: 300' (TABLE 1016.1) MAX. TRAVEL DISTANCE S -1, F -1 OCCUPANCY: 250' (TABLE 1016.1) B. MAX. COMMON PATH OF EGRESS TRAVEL: 100' (1014.3 EXCEPTION 1) C. MINIMUM CORRIDOR WIDTH: 44" (1018.2) D. REQUIRED EGRESS WIDTH: 0.2 PER OCCUPANT (1005.1)= 79.8" REQUIRED REQUIRED STAIR EGRESS WIDTH: 0.3 PER OCCUPANT (1005.1)= 119.7' REQUIRED E. MINIMUM CLEAR DOOR OPENING: 32 INCHES (1008.1.1) F. MAXIMUM DEAD END CORRIDOR: 50' (1018.4) LEGEND: EXIT EXIST. WALLS / PARTITION TO REMAIN NEW PARTITION WALL LIGHTED EXIT SIGNAGE W/ BATTERY BACKUP PER IBC SECTION 1011, CONFIRM OPERATION FOR EXISTING. ADD WHERE NOT EXISTING. KEY NOTES: 1. EXISTING TENANT DEMISING WALL 2. NO WORK IN THIS AREA 3. EXISTING STOREFRONT SYSTEM AND ACCESSIBLE ENTRANCE /EXIT TO REMAIN 4. NEW EXIT SIGN PER IBC SECTION 1011 5. EXISTING EXIT SIGN TO REMAIN 6. EXISTING ELECTRICAL TRANSFORMER AND ELECTRICAL PANELS TO REMAIN 7. EXISTING PARKING STALLS TO REMAIN, TYP 8. STORAGE RACKING UNDER SEPARATE PERMIT 9. NEW CANVAS AWNING, SEE ELEVATION 2/10.1 F „. COPY Permit No. 8 Phret review approval is subject to errors and omissions. of construction documents does not authorize of any adopted code or ordinance. Receipt Lpproved Field Copy ► « 01 is acknowledged: By Date:. 5(25(19_ City Of ltikwila BUILDING DIVISION ENERGY CODE COMPLIANCE: 1. PROJECT SHALL COMPLY WITH 2009 WASHINGTON STATE ENERGY CODE INCLUDING BUT NOT LIMITED TO THE FOLLOWING PROVISIONS: A. 1310.2 SEMI - HEATED SPACES: FOR SEMI - HEATED SPACES HEATED BY OTHER FUELS ONLY, WALL INSULATION IS NOT REQUIRED FOR THOSE WALLS SEPARATE SEMI - HEATED SPACES FROM THE EXTERIOR PROVIDED THAT THE SPACE IS HEATED SOLELY BY A HEATING SYSTEM CONTROLLED Y A THERMOSTAT WITH A MAXIMUM SET POINT CAPACITY OF 45 DEGREES, MOUNTED NO LOWER THAN THE HEATING UNIT. B. 1314 AIR LEAKAGE: 1314.1 BUILDING ENVELOPE SEALING: THE FOLLOWING AREAS OF THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED OR WEATHER - STRIPPED TO MINIMIZE AIR LEAKAGE: • JOINTS AROUND FENESTRATION AND DOOR FRAMES; • JUNCTIONS BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AT BUILDING CORNERS, BETWEEN WALLS AND STRUCTURAL FLOORS OR ROOFS, AND BETWEEN WALLS AND ROOF OR ROOF PANELS; • OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH THE ROOFS, WALLS AND FLOORS; • SITE -BUILT FENESTRATION AND DOORS; • BUILDING ASSEMBLIES USED AS DUCTS OR PLENUMS; • JOINTS, SEAMS AND PENETRATIONS OF VAPOR RETARDERS; AND • ALL OTHER OPENINGS IN THE BUILDING ENVELOPE. C. 1314.2 GLAZING AND DOORS: AIR LEAKAGE FOR FENESTRATION AND DOORS SHALL BE DETERMINED IN ACCORDANCE WITH NFRC 400 OR AAMA /WDMA /CSA 101/IS2/A440 OR ASTM E283 AS SPECIFIED BELOW. AIR LEAKAGE SHALL BE DETERMINED BY A LABORATORY ACCREDITED BY A NATIONALLY RECOGNIZED ACCREDITATION ORGANIZATION, SUCH AS THE NATIONAL FENESTRATION RATING COUNCIL, AND SHALL BE LABELED AND CERTIFIED BY THE MANUFACTURER. AIR LEAKAGE SHALL NOT EXCEED: • 1.0 CFM /FT2 FOR GLAZED SWINGING ENTRANCE DOORS AND REVOLVING DOORS, TESTED AT A PRESSURE OF AT LEAST 1.57 POUNDS PER SQUARE FOOT (PSF) IN ACCORDANCE WITH NFRC 400, AAMA /WDMA /CSA 101/IS2/A440, OR ASTM E283. • 0.04 CFM /FT2 FOR CURTAIN WALL AND STOREFRONT GLAZING, TESTED AT A PRESSURE OF AT LEAST 1.57 POUNDS PER SQUARE FOOT (PSF) IN ACCORDANCE WITH NFRC 400, AAMA/WDMA /CSA 101/IS2/A440, OR ASTM E283. • 0.2 CFM /FT2 FOR ALL OTHER PRODUCTS WHEN TESTED AT A PRESSURE OF AT LEAST 1.57 POUNDS PER SQUARE FOOT (PSF) IN ACCORDANCE WITH NFRC 400 OR AAMA/WDMA /CSA 101/IS2/A440, OR 0.3 CFM /FT2 WHEN TESTED AT A PRESSURE OF AT LEAST 6.24 POUNDS PER SQUARE FOOT (PSF) IN ACCORDANCE WITH AAMA /WDMA /CSA 101 /I.S /A440. D. 1314.6 CONTINUOUS AIR BARRIER: NOT REQUIRED FOR BUILDINGS LESS THAN FIVE STORIES RECEIVED MAY 15 2012 PERMIT CENTER 1)(7 (z- 098 arch! t e s t s 2505 Third Avenue Suite 324 Seattle, WA 98121 206.720.7001 phone 206.120.2949 fax www.craftarchitects.com 0 O CD CO 1 W W GO CO Ey!. W Q T- M M co\ 0 U) C°) co CONSULTANT REVISIONS: FOR PERMIT 02/28/12 OWNER REVISION 03/15/12 FOR CONSTRUCTION 04/02/12 SHEET TITLE: ARCHITECTURAL SITE/ EGRESS /WAREHOUSE PLAN DATE: DESIGN: 04/02/12 DRAWN: PROJECT NO: APPROVED: SAD 11- 458.06 KMC ORIGINAL DRAWING IS 24" x 36 ". SCALE ENTITIES ACCORDINGLY IF REDUCED SHEET NO: A0.1 COPYRIGHT CRAFT ARCHITECTS 2012 II i ANNEX OFF1ICE +so +42 +42 �/ LUNCHROOM 85 OCC 101 0 7 Yy POWER /COMM PLAN SCALE: 1/8" = 1 ' -0" REFLECTED CEILING PLAN SCALE: 1/8" = 1' -0" RESPONSIBILITY NOTES: 1. THE FOLLOWING SCOPE OF WORK TO BE PROVIDED BY THE FOLLOWING ENTmES: - ALL ELECTRICAL (HIGH VOLTAGE) BY: GC - PATH (1/2" CONDUIT TO ACCESSIBLE CEILING SPACE, CEILING ACCESS, ETC.), BOX AND PULL STRING FOR ALL CABLE (HIGH, LOW, SECURITY, VIDEO, COAX) BY: GC - CORE DRILLS FOR ALL WORK WITHIN CONTRACT BY: GC - TRENCHING FOR ALL WORK WITHIN CONTRACT BY: GC - SECURITY CABLING BY: OWNER/TENANT - DATA CABLING (LOW VOLTAGE) BY: OWNER/TENANT VENDOR - PHONE CABLING (LOW VOLTAGE) BY: OWNER/TENANT VENDOR - VIDEO CABLING (LOW VOLTAGE) BY: OWNER/TENANT VENDOR 2. GC RESPONSIBLE FOR COORDINATING SCHEDULE AND SCOPE WITH ALL OWNER /TENANT VENDORS. TO COORDINATE SCHEDULE: GC & OWNER/TENANT VENDORS TO PARTICIPATE IN A PRECONSTRUCTION MEETING OR CONFERENCE CALL. THE PROJECT SCOPE MAY ALSO NECESSITATE WEEKLY CONFERENCE CALLS DURING CONSTRUCTION - TO BE VERIFIED BY CRAFT. IF NECESSARY GC WILL ASSIST IN THE PREPARATION OF A COMPREHENSIVE SCHEDULE DESCRIBING THE WORK OF ALL VENDORS. 3. WORK SEQUENCE: THE WORK SHALL BE PERFORMED IN THE WAY WHICH SHALL PROVIDE THE LEAST POSSIBLE INTERFERENCE WITH THE ACTIVITIES OF THE OWNER'S AND LESSOR'S PERSONNEL AND PERMIT AN ORDERLY TRANSFER OF PERSONNEL AND EQUIPMENT TO THE NEW FACILITIES. 4. FULL LESSOR OCCUPANCY: THE LESSOR WILL OCCUPY THE SITE AND EXISTING BUILDING DURING CONSTRUCTION. COOPERATE WITH THE LESSOR TO MINIMIZE CONFLICTS AND FACILITATE LESSOR USAGE. PERFORM THE WORK SO AS NOT TO INTERFERE WITH THE LESSOR'S OPERATIONS. 5. MATERIALS AND EQUIPMENT IN OCCUPIED SPACE: STORAGE AT JOB SITE PRIOR TO INCORPORATION SHALL BE A MAXIMUM OF 48 HOURS. 6. GC SHALL COORDINATE SCHEDULE AND DAILY ACTION ITEMS WITH OWNER AND ARCHITECT TO ENSURE SECURITY IS NOT COMPROMISED. 7. OWNER /TENANT VENDORS ARE RESPONSIBLE FOR VERIFICATION OF SCOPE. ARCHITECT'S INTENT IS FOR VENDORS TO PERFORM 'BEST PRACTICE' WORK (COMPLIANCE WITH OWNER/TENANT STANDARDS, LOCAL BUILDING CODES, ETC.) - VENDORS TO PRICE WORK ACCORDINGLY. 8. OWNER /TENANT VENDORS TO NOTIFY ARCHITECT OF ADDITIONAL OR MODIFIED SCOPE REQUIRED. ANNEX OFFICE 100 CEILING GENERAL NOTES: 1. SUSPENDED CEILING PANELS, LIGHT FIXTURES AND HVAC SUPPLY /RETURN TO BE REPLACED, TYPICAL THROUGHOUT. GWB CEILINGS, CEILING GRID & SPRINKLER HEADS TO REMAIN, MODIFY AS SHOWN OR REQUIRED TO SUIT NEW OFFICE LAYOUT 2. REPAIR /REPLACE SPRINKLER CAPS (SOME MISSING) 3. CLEAN ALL HVAC GRILLS/VENTS 4. PROJECT TO BE ELECTRICAL AND MECHANICAL DESIGN - BUILD. LIGHTING SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: A. IBC 1006.1 - ILLUMINATION REQUIREMENT 1. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. B. IBC 1006.2 - ILLUMINATION LEVEL 1. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT- CANDLE (11 LUX) AT THE FLOOR LEVEL. C. IBC 1006.3 - ILLUMINATION EMERGENCY POWER 1. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISE'S ELECTRIC SUPPLY. 1.1. LOCATIONS INCLUDE: DEDICATED EGRESS ROUTES IN LARGER ROOMS OR SPACES, PUBLIC OR COMMON EGRESS ELEMENTS, ESSENTIAL PORTIONS OF THE INTERIOR EGRESS SYSTEM, INTERIOR EXIST DISCHARGE ELEMENTS, AND EXTERIOR PORTIONS OF THE EXIT DISCHARGE. D. EACH ROOM SHALL COMPLY WITH THE PROVISIONS OF WSEC 1513 INCLUDING BUT NOT LIMITED TO LOCAL CONTROL AND ACCESSIBILITY, DAY LIGHTING AND COMMISSIONING. E. PER 2009 WSEC 1314.4, RECESSED LIGHTING FIXTURES: WHEN INSTALLED IN THE BUILDING ENVELOPE, RECESSED LIGHTING FIXTURES SHALL BY TYPE IC RATED, AND CERTIFIED UNDER ASTM E283 TO HAVE NO MORE THAN 2.0 CFM AIR MOVEMENT FROM THE CONDITIONED SPACE TO THE CEILING CAVITY. THE LIGHTING FIXTURE SHALL BE TESTED AT 75 PASCALS OR 1.57 LBS /FT2 PRESSURE DIFFERENCE AND HAVE A LABEL ATTACHED, SHOWING COMPLIANCE WITH THIS TEST METHOD. RECESSED LIGHTING FIXTURES SHALL BE INSTALLED WITH A GASKET OR CAULK BETWEEN THE FIXTURE AND CEILING TO PREVENT AIR LEAKAGE. 5. HVAC SOLUTION SHALL MEET THE FOLLOWING MINIMUM REQUIREMENT: A. VENTILATION REQUIREMENTS FOR RESTROOMS PER WASHINGTON STATE MECHANICAL CODE (WAC 51 -52) 6. EXIT SIGNAGE SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: A. ALL REQUIRED EXIT SIGNS SHALL HAVE LETTERS SIX INCHES HIGH MINIMUM AND SHALL CONFORM WITH ALL APPLICABLE CODES. 7. THE BUILDING IS FULLY SPRINKLERED. THE FIRE PROTECTION CONTRACTOR SHALL PROVIDE FIRE PROTECTION DRAWINGS AS REQUIRED BY THE GOVERNING AUTHORITY, THE FIRE PROTECTION CONTRACTOR SHALL SUBMIT DRAWINGS TO THE ARCHITECT FOR REVIEW PRIOR TO COMMENCING WITH THE WORK. REVIEWED FOR DE COMPLIANCE APPROVED MAY 2 3 2012 City of Tukwila BUILDING DIVISION 0 M 5` -0" LUNCHROOM 85 OCC 101 FLOOR PLAN SCALE: 1 /8" = 1'-0" GENERAL NOTES: 1. ALL EXISTING COLUMNS, EXTERIOR WALLS, EXTERIOR WINDOWS, LIGHT FIXTURES AND STRUCTURAL MEMBERS TO REMAIN, U.O.N. 2. ALL FLOOR FINISHES AND WALL BASE TO BE REPLACED, TYPICAL THROUGHOUT. ALL FLOORS TO BE PREPARED TO RECEIVE NEW FINISH. CONCRETE SLAB TO RECEIVE NEW SEAL WHERE SAW -CUT AND PATCHED. PATCH AND PAINT ALL OFFICE WALLS. 3. ALL FINISHES PER ROOM FINISH SCHEDULE SHEET A6.1 4. FOR ACCESSIBILITY COMPLIANCE REFER TO SHEET T1.2. 5. THERE SHALL BE NO EXPOSED PIPE, CONDUIT, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED AND FINISHED, UNLESS OTHERWISE NOTED AS EXPOSED CONSTRUCTION ON THE DRAWING. 6. OFFSET STUDS, WHERE REQUIRED, SO THAT FINISHED PARTITION SURFACE WILL BE FLUSH, UNLESS OTHERWISE NOTED. PROVIDE FURRING AT EXISTING PARTITIONS AS REQUIRED TO INSTALL ELECTRICAL ITEMS AS INDICATED ON THE DRAWINGS. 7. DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS OR DETAILS ARE TO BE (4) INCHES FROM ADJACENT WALL AT HINGE SIDE OF DOOR OR CENTERED BETWEEN WALLS. 8. FINISHED FACES OF NEW PARTITIONS PARALLEL TO EXISTING FRAMING SHALL ALIGN. 9. GC SHALL BE RESPONSIBLE FOR PROVIDING ALL BLOCKING FOR ALL WALL AND CEILING MOUNTED ITEMS, INCLUDING HARDWARE, LIGHT FIXTURES, GRAB BARS, CASEWORK, AND ALL OWNER PROVIDED ITEMS. PROVIDE SHEET METAL REINFORCING (8" HORIZONTALLY MOUNTED STRIP OF 20 GA. GALVANIZED SHEET METAL) CONCEALED IN PARTmONS WHERE WALL OR CEILING MOUNTED ITEM IS INDICATED ON DRAWINGS. 10. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DESIGNER PRIOR TO MANUFACTURE OF ANY CASEWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATED WORK. POWER GENERAL NOTES: 1. EACH ROOM SHALL HAVE SEPARATE SWITCHING BY ELECTRICAL DESIGN /BUILD TO MEET WSEC 1513. 2. ALL FURNITURE AND WORKSTATIONS PROVIDED AND INSTALLED BY OWNER. NEW FURNITURE PANELS WILL BE POWERED. ELECTRICAL CONTRACTOR TO PROVIDE PANEL TO PANEL ELECTRICAL CONNECTIONS, POWER CONNECTION TO WORKSTATIONS (WHIPS /BASE POWER INFEEDS) AND DUPLEX RECEPTACLE INSTALLATION. COORDINATE POWER, VOICE /DATA AND SECURITY LOCATIONS AND INSTALLATION REQUIREMENTS W/ FURNITURE VENDOR, TYP. 3. ALL WALL MOUNTED TELEPHONE AND ELECTRICAL OUTLETS TO BE INSTALLED 15" ABOVE FLOOR UNLESS OTHERWISE NOTED. 4. ALL CORE DRILL LOCATIONS SHALL BE VERIFIED WITH DESIGNER PRIOR TO DRILLING. 5. MAINTAIN A FOUR INCH HORIZONTAL CLEARANCE IN ALL DIRECTIONS, MIN. FROM EDGE OF COVER PLATE, FOR WALL MOUNTED OUTLETS, OR FROM EDGE OF MONUMENT FOR FLOOR MOUNTED OUTLETS, WHEN ADJACENT TO A WALL, COLUMN, OR SIMILAR ELEMENTS, U.N.O. 6. INDICATED DIMENSIONS ARE TO THE CENTER OF THE COVER PLATE OR MONUMENT: CLUSTERS OF OUTLETS ARE DIMENSIONED TO THE CENTER OF THE CLUSTER, U.N.O.: GANG COVER PLATES SHALL BE ONE -PIECE TYPE U.N.O. 7. ALL EXISTING ELECTRICAL / TELEPHONE OUTLETS NOT SHOWN ARE EXISTING TO REMAIN. POWER & COMMUNICATION OUTLETS ARE SHOWN IN IDEAL LOCATIONS. REUSE EXISTING ELECTRICAL/ TELEPHONE OUTLETS WHEN LOCATED NEAR IDEAL LOCATIONS AND RELOCATE EXISTING ELECTRICAL/ TELEPHONE OUTLETS WHERE POSSIBLE. 8. FURNITURE SHOWN IS FOR REFERENCE ONLY AND IS N.I.C. LOCATION OF OUTLETS IN PRIVATE OFFICES TO BE COORDINATED WITH FURNITURE VENDOR. LEGEND: Elm EXIST. WALLS / PARTITION TO REMAIN NEW PARTITION WALL INTERNALLY LIGHTED EXIT SIGNAGE W/ BATTERY BACKUP PER IBC SECTION 1011, CONFIRM OPERATION FOR EXISTING. ADD WHERE NOT EXISTING. 2X4 LAY -IN FLUORESCENT LIGHT, 18 .CEO PARABOLIC, (2) T -5 LAMPS PER FIXTURE v.. C r ch i 1~ ec t s 2505 Third Avenue Suite 324 Seattle, WA 98121 206,720.7001 phone 206.720.2949 fax www.crattarchitects.tom CONSULTANT 2x4 LAY -IN FLUORESCENT "NIGHT LIGHT", 18 CELL PARABOLIC, FOR EGRESS ILLUMINATION ® MIN. 1 FC W/ BATTERY BACKUP PER IBC SECTION 1003.2.9., (2) T -5 LAMPS PER FIXTURE -�- NEW PENDANT LIGHT, PROVIDED BY OWNER, INSTALLED BY CONTRACTOR, TO BE ON OWN SWITCH 0 EXHAUST FAN SUSPENDED ACOUSTIC CEILING TILE AND GRID: ARMSTRONG, CORTEGA, SECOND LOOK II, 2767, 24" X 48" ANGLED TEGULAR TILE, WHITE WITH CLASS "A" 15/16" PRELUDE GRID SYSTEM, WHITE OPEN TO STRUCTURE LIGHT SWITCH (T =SWITCH ON TIMER, D= SWITCH ON DIMMER) WALL MOUNTED DUPLEX OUTLET (DED = DEDICATED) WALL MOUNTED FOURPLEX RECEPTACLE OUTLET WALL MOUNTED VOICE /DATA PORT - (2) VOICE /(2) DATA IN SINGLE GANG BOX, UNO KEY NOTES: 1. NEW PLASTIC LAMINATE COUNTERTOP, BASE AND UPPER CABINETS WITH DOUBLE COMPARTMENT, TOP MOUNT SINK, DISHWASHER AND GARBAGE DISPOSAL 2. PROVIDE WATER SUPPLY LINE FOR NEW (F010) PLUMBED HOT /COLD WATER DISPENSER 3. PROVIDE WATER SUPPLY LINE TO (F010) REFRIGERATORS 4. PROVIDE WATER SUPPLY LINE TO (F010) COFFEE MAKER 5. INFILL & PATCH EXISTING OPENING TO MATCH ADJACENT. FILL WITH BATT INSULATION 6. PENDANT CENTERED OVER COUNTERTOP 7. EXISTING CEILING GRID, MODIFY /REPAIR AS NECESSARY TO RESTORE GRID TO 2'X4' STANDARD GRID 8. EXISTING EXTERIOR LIGHT FIXTURE, TO REMAIN. GC TO CONFIRM /PROVIDE ILLUMINATION POWER PER IBC 1006.3 9. REMOVE EXISTING DOOR, ATTEMPT TO RE -USE AS DOOR 102, NEW HARDWARE AND CLOSER 10. REMOVE EXISTING DOUBLE DOORS, RE -USE FOR DOOR 101, NEW DOOR HARDWARE AND CLOSER 11. REMOVE & STORE ROLL-UP FIRE DOOR FOR FUTURE INSTALLATION ON SITE REVISIONS: FOR PERMIT 02/28/12 / T \ 03/15/12 OWNER REVISION FOR CONSTRUCTION 04/02/12 SHEET TITLE: FLOOR PLAN, RCP, POWER /COMM PLAN 04/02/12 DATE: DESIGN: DRAWN: PROJECT NO: APPROVED: SAD 11- 458.06 KMC ORIGINAL DRAWING IS 24" x 36 ". SCALE ENTITIES ACCORDINGLY IF REDUCED SHEET NO: A2.1 COPYRIGHT CRAFT ARCHITECTS 2012 RECEIVED MAY 15 2012 p&12... oit PERMIT CENTER 2QQ1k1 103 E FLEC. LEG( EXISTING STORAGE J EXISTING OFFICE �ll N ROM 103 POWER /COMM PLAN SCALE: 1/8" = 1' -0" CK� 'EXISTING OFFICE L AREA OF WORK III= L:. 0 1 EX STING STORPCE T 11 Z 7 11 C5) REFLECTED CEILING PLAN SCALE: 1/8" = 1' -0" RESPONSIBILITY NOTES: 1. THE FOLLOWING SCOPE OF WORK TO BE PROVIDED BY THE FOLLOWING ENTITIES: - ALL ELECTRICAL (HIGH VOLTAGE) BY: GC - PATH (1/2" CONDUIT TO ACCESSIBLE CEIUNG SPACE, CEILING ACCESS, ETC.), BOX AND PULL STRING FOR ALL CABLE (HIGH, LOW, SECURITY, VIDEO, COAX) BY: GC - CORE DRILLS FOR ALL WORK WITHIN CONTRACT BY: GC - TRENCHING FOR ALL WORK WITHIN CONTRACT BY: GC - SECURITY CABLING BY: OWNER/TENANT - DATA CABLING (LOW VOLTAGE) BY: OWNER/TENANT VENDOR - PHONE CABLING (LOW VOLTAGE) BY: OWNER/TENANT VENDOR - VIDEO CABLING (LOW VOLTAGE) BY: OWNER/TENANT VENDOR 2. GC RESPONSIBLE FOR COORDINATING SCHEDULE AND SCOPE WITH ALL OWNER/TENANT VENDORS. TO COORDINATE SCHEDULE: GC & OWNER /TENANT VENDORS TO PARTICIPATE IN A PRECONSTRUCTION MEETING OR CONFERENCE CALL. THE PROJECT SCOPE MAY ALSO NECESSITATE WEEKLY CONFERENCE CALLS DURING CONSTRUCTION - TO BE VERIFIED BY CRAFT. IF NECESSARY GC WILL ASSIST IN THE PREPARATION OF A COMPREHENSIVE SCHEDULE DESCRIBING THE WORK OF ALL VENDORS. 3. WORK SEQUENCE: THE WORK SHALL BE PERFORMED IN THE WAY WHICH SHALL PROVIDE THE LEAST POSSIBLE INTERFERENCE WITH THE ACTIVITIES OF THE OWNER'S AND LESSOR'S PERSONNEL AND PERMIT AN ORDERLY TRANSFER OF PERSONNEL AND EQUIPMENT TO THE NEW FACILmES. 4. FULL LESSOR OCCUPANCY: THE LESSOR WILL OCCUPY THE SITE AND EXISTING BUILDING DURING CONSTRUCTION. COOPERATE WITH THE LESSOR TO MINIMIZE CONFLICTS AND FACILITATE LESSOR USAGE. PERFORM THE WORK SO AS NOT TO INTERFERE WITH THE LESSOR'S OPERATIONS. 5. MATERIALS AND EQUIPMENT IN OCCUPIED SPACE: STORAGE AT JOB SITE PRIOR TO INCORPORATION SHALL BE A MAXIMUM OF 48 HOURS. 6. GC SHALL COORDINATE SCHEDULE AND DAILY ACTION ITEMS WITH OWNER AND ARCHITECT TO ENSURE SECURITY IS NOT COMPROMISED. 7. OWNER/TENANT VENDORS ARE RESPONSIBLE FOR VERIFICATION OF SCOPE. ARCHITECT'S INTENT IS FOR VENDORS TO PERFORM 'BEST PRACTICE' WORK (COMPLIANCE WITH OWNER/TENANT STANDARDS, LOCAL BUILDING CODES, ETC.) - VENDORS TO PRICE WORK ACCORDINGLY. 8. OWNER /TENANT VENDORS TO NOTIFY ARCHITECT OF ADDITIONAL OR MODIFIED SCOPE REQUIRED. \\ CEILING GENERAL NOTES: 1. SUSPENDED CEILING PANELS, LIGHT FIXTURES AND HVAC SUPPLY /RETURN TO REMAIN, TYPICAL THROUGHOUT. GWB CEILINGS, CEILING GRID & SPRINKLER HEADS TO REMAIN, MODIFY AS SHOWN OR REQUIRED TO SUIT NEW OFFICE LAYOUT 2. REPAIR /REPLACE SPRINKLER CAPS (SOME MISSING) 3. CLEAN ALL HVAC GRILLS /VENTS 4. PROJECT TO BE ELECTRICAL AND MECHANICAL DESIGN- BUILD. LIGHTING SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: A. IBC 1006.1 - ILLUMINATION REQUIREMENT 1. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. B. IBC 1006.2 - ILLUMINATION LEVEL 1. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT- CANDLE (11 LUX) AT THE FLOOR LEVEL. C. IBC 1006.3 - ILLUMINATION EMERGENCY POWER 1. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISE'S ELECTRIC SUPPLY. 1.1. LOCATIONS INCLUDE: DEDICATED EGRESS ROUTES IN LARGER ROOMS OR SPACES, PUBLIC OR COMMON EGRESS ELEMENTS, ESSENTIAL PORTIONS OF THE INTERIOR EGRESS SYSTEM, INTERIOR EXIST DISCHARGE ELEMENTS, AND EXTERIOR PORTIONS OF THE EXIT DISCHARGE. D. EACH ROOM SHALL COMPLY WITH THE PROVISIONS OF WSEC 1513 INCLUDING BUT NOT UNITED TO LOCAL CONTROL AND ACCESSIBILITY, DAY LIGHTING AND COMMISSIONING. E. PER 2009 WSEC 1314.4, RECESSED LIGHTING FIXTURES: WHEN INSTALLED IN THE BUILDING ENVELOPE, RECESSED LIGHTING FIXTURES SHALL BY TYPE IC RATED, AND CERTIFIED UNDER ASTM E283 TO HAVE NO MORE THAN 2.0 CFM AIR MOVEMENT FROM THE CONDITIONED SPACE TO THE CEILING CAVITY. THE LIGHTING FIXTURE SHALL BE TESTED AT 75 PASCALS OR 1.57 L8S /FT2 PRESSURE DIFFERENCE AND HAVE A LABEL ATTACHED, SHOWING COMPUANCE WITH THIS TEST METHOD. RECESSED LIGHTING FIXTURES SHALL BE INSTALLED WITH A GASKET OR CAULK BETWEEN THE FIXTURE AND CEILING TO PREVENT AIR LEAKAGE. 5. HVAC SOLUTION SHALL MEET THE FOLLOWING MINIMUM REQUIREMENT: A. VENTILATION REQUIREMENTS FOR RESTROOMS PER WASHINGTON STATE MECHANICAL CODE (WAC 51 -52) 6. EXIT SIGNAGE SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: A. ALL REQUIRED EXIT SIGNS SHALL HAVE LETTERS SIX INCHES HIGH MINIMUM AND SHALL CONFORM WITH ALL APPUCABLE CODES. 7. THE BUILDING IS FULLY SPRINKLERED. THE FIRE PROTECTION CONTRACTOR SHALL PROVIDE ARE PROTECTION DRAWINGS AS REQUIRED BY THE GOVERNING AUTHORITY. THE FIRE PROTECTION CONTRACTOR SHALL SUBMIT DRAWINGS TO THE ARCHITECT FOR REVIEW PRIOR TO COMMENCING WITH THE WORK. EXISTING OFFICE 00 EXISTING STORAGE K 1 L _1 1 � FLOOR PLAN SCALE: 1/8" = 1' -0" GENERAL NOTES: 1. ALL EXISTING COLUMNS, EXTERIOR WALLS, EXTERIOR WINDOWS, LIGHT FIXTURES AND STRUCTURAL MEMBERS TO REMAIN, U.O.N. 2. ALL FLOOR FINISHES AND WALL BASE TO REMAIN 3. FOR ACCESSIBIUTY COMPLIANCE REFER TO SHEET T1.2. 4. THERE SHALL BE NO EXPOSED PIPE, CONDUIT, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED AND FINISHED, UNLESS OTHERWISE NOTED AS EXPOSED CONSTRUCTION ON THE DRAWING. 5. OFFSET STUDS, WHERE REQUIRED, SO THAT FINISHED PARTITION SURFACE WILL BE FLUSH, UNLESS OTHERWISE NOTED. PROVIDE FURRING AT EXISTING PARTITIONS AS REQUIRED TO INSTALL ELECTRICAL ITEMS AS INDICATED ON THE DRAWINGS. 6. DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS OR DETAILS ARE TO BE (4) INCHES FROM ADJACENT WALL AT HINGE SIDE OF DOOR OR CENTERED BETWEEN WALLS. 7. FINISHED FACES OF NEW PARTITIONS PARALLEL TO EXISTING FRAMING SHALL ALIGN. 8. GC SHALL BE RESPONSIBLE FOR PROVIDING ALL BLOCKING FOR ALL WALL AND CEILING MOUNTED ITEMS, INCLUDING HARDWARE, LIGHT FIXTURES, GRAB BARS, CASEWORK, AND ALL OWNER PROVIDED ITEMS. PROVIDE SHEET METAL REINFORCING (8" HORIZONTALLY MOUNTED STRIP OF 20 GA. GALVANIZED SHEET METAL) CONCEALED IN PARTITIONS WHERE WALL OR CEILING MOUNTED ITEM IS INDICATED ON DRAWINGS. 9. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DESIGNER PRIOR TO MANUFACTURE OF ANY CASEWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATED WORK. POWER GENERAL NOTES: 1. EACH ROOM SHALL HAVE SEPARATE SWITCHING BY ELECTRICAL DESIGN /BUILD TO MEET WSEC 1513. 2. ALL FURNITURE AND WORKSTATIONS PROVIDED AND INSTALLED BY OWNER. NEW FURNITURE PANELS WILL BE POWERED. ELECTRICAL CONTRACTOR TO PROVIDE PANEL TO PANEL ELECTRICAL CONNECTIONS, POWER CONNECTION TO WORKSTATIONS (WHIPS /BASE POWER INFEEDS) AND DUPLEX RECEPTACLE INSTALLATION. COORDINATE POWER, VOICE /DATA AND SECURITY LOCATIONS AND INSTALLATION REQUIREMENTS W/ FURNITURE VENDOR, TYP. 3. ALL WALL MOUNTED TELEPHONE AND ELECTRICAL OUTLETS TO BE INSTALLED 15" ABOVE FLOOR UNLESS OTHERWISE NOTED. 4. ALL CORE DRILL LOCATIONS SHALL BE VERIFIED WITH DESIGNER PRIOR TO DRILLING. 5. MAINTAIN A FOUR INCH HORIZONTAL CLEARANCE IN ALL DIRECTIONS, MIN. FROM EDGE OF COVER PLATE, FOR WALL MOUNTED OUTLETS, OR FROM EDGE OF MONUMENT FOR FLOOR MOUNTED OUTLETS, WHEN ADJACENT TO A WALL, COLUMN, OR SIMILAR ELEMENTS, U.N.O. 6. INDICATED DIMENSIONS ARE TO THE CENTER OF THE COVER PLATE OR MONUMENT: CLUSTERS OF OUTLETS ARE DIMENSIONED TO THE CENTER OF THE CLUSTER, U.N.O.: GANG COVER PLATES SHALL BE ONE -PIECE TYPE U.N.O. 7. ALL EXISTING ELECTRICAL / TELEPHONE OUTLETS NOT SHOWN ARE EXISTING TO REMAIN. POWER & COMMUNICATION OUTLETS ARE SHOWN IN IDEAL LOCATIONS. REUSE EXISTING ELECTRICAL/ TELEPHONE OUTLETS WHEN LOCATED NEAR IDEAL LOCATIONS AND RELOCATE EXISTING ELECTRICAL/ TELEPHONE OUTLETS WHERE POSSIBLE. 8. FURNITURE SHOWN IS FOR REFERENCE ONLY AND IS N.I.C. LOCATION OF OUTLETS IN PRIVATE OFFICES TO BE COORDINATED WITH FURNITURE VENDOR. LEGEND: EXIST. WALLS / PARTITION TO REMAIN NEW PARTITION WALL INTERNALLY LIGHTED EXIT SIGNAGE W/ BATTERY BACKUP PER IBC SECTION 1011, CONFIRM OPERATION FOR EXISTING. ADD WHERE NOT EXISTING. R RELOCATED LIGHT FIXTURE C archi t e c t s 2505 Third Avenue Suite 324 Seattle, WA 98121 206.720.7001 phone 206.720.2949 fax www.craftarchltects.com Fe* LIGHT SWITCH (T= SWITCH ON TIMER, D= SWITCH ON DIMMER) CONSULTANT WALL MOUNTED DUPLEX OUTLET (DED = DEDICATED) WALL MOUNTED FOURPLEX RECEPTACLE OUTLET WALL MOUNTED VOICE /DATA PORT - (2) VOICE /(2) DATA IN SINGLE GANG BOX, UNO KEY NOTES: oar IsamininM11..... REVIEWED FOR ,DE COMPLIANCE APPROVED MAY 2 3 2012 City of Tukwila BUILDING DIVISION 1. DEMOLISH EXISTING STRIP CURTAIN, INFILL & PATCH OPENING TO MATCH ADJACENT. FILL WITH BAIT INSULATION 2. EXISTING CEILING GRID AND LIGHT FIXTURES TO REMAIN 3. EXISTING WATER HEATER TO BE RELOCATED TO OUTSIDE OF ROOM 103, SEE KEYNOTE 8 FOR NEW LOCATION 4. NEW TRIPLE BASIN SINK 5. EXISTING WALL MOUNTED SINK TO REMAIN 6. FUTURE FURNITURE 7. RELOCATE /REMOVE LIGHT FIXTURES THAT ARE IN CONFLICT WITH NEW WALL 8. NEW LOCATION OF EXISTING WATER HEATER VGP=o4/43 RECEIVED MAY 15 2012 PERMIT CENTER REVISIONS: FOR PERMIT 02/28/12 / I \OWNER REVISION 03/15/12 FOR CONSTRUCTION 04/02/12 SHEET TITLE: DATE: DESIGN: FLOOR PLAN, RCP, POWER /COMM PLAN 04/02/12 DRAWN: PROJECT NO: APPROVED: SAD 11- 458.06 KMC ORIGINAL DRAWING IS 24" x 36 ". SCALE ENTITIES ACCORDINGLY IF REDUCED SHEET NO: A2.2 COPYRIGHT CRAFT ARCHITECTS 2012