Loading...
HomeMy WebLinkAboutPermit PG12-159 - WESTFIELD MALL - HVACWESTFIELD MALL HVAC 2800 SOUTHCENTER MALL PG12 -159 Parcel No.: Address: City mTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206. 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov PLUMBING /GAS PIPING PERMIT 9202470010 -- 2800 SOUTHCENTER MALL TUKW Project Name: WESTFIELD MALL - HVAC Permit Number: Issue Date: Permit Expires On: PG12 -159 08/29/2012 02/25/2013 Owner: Name: Address: Contact Person: Name: Address: Email: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 DARLA DOLL 7717 DETROIT AV SW , SEATTLE WA 98106 DARLA. D O LL @MAC MILLER. C O M Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA 98106 Contractor License No: MACDOFS980RU Phone: 206 - 768 -4278 Phone: 206 - 768 -4180 Expiration Date: 12/31/2012 DESCRIPTION OF WORK: GAS PIPING FOR WORK TO REPLACE (3) PENTHOUSE BUILT -UP UNITS WITH PACKAGED ROOF TOP AC UNTTS Value of Plumbing /Gas Piping: Fees Collected: Electrical Service Provided by: $15,000.00 $120.75 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Uniform Plumbing Code Edition: 2009 International Fuel Gas Code Edition: 2009 Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pr construction or the performance of work on the back of this permit. Signature: e to give authority to violate or cancel the provisions of any other state or local laws regulating • I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions Date: 1{2c / Z— Print Name: }— J (2:t 'C' `(DL. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG12 -159 Printed: 08 -29 -2012 • • PERMIT CONDITIONS Permit No. PG12-159 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG12-159 Printed: 08 -29 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing /Gas. Permit No. YC "f o)'' Project No Date Application Accepted Date; Application Expires: :' �, < (For ojce use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: King Co Assessor's Tax No.: 359700 -0245 2800 Southcenter Pkwy Tukwila, WA 98188 WESTFIELD SOUTHCENTER - PH 1 Suite Number: ROOF Floor: ROOF PROPERTY OWNER Name: DARLA DOLL Name: WESTFIELD SOUTHCENTER Cih': SEATTLE State: WA Zip: 98106 Address: 2800 SOUTHCENTER MALL Email: DARLA.DOLL @MACMILLER.COM City: TUKWILA State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication .. Name: DARLA DOLL Address: 7717 DETROIT AVE SW Cih': SEATTLE State: WA Zip: 98106 Phone: (206) 768 -4278 Fax: (206) 768 -4279 Email: DARLA.DOLL @MACMILLER.COM New Tenant: ❑ Yes m ..No PLUMBING CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 768 -4278 Fax: (206) 768 -4278 Contr Reg No.: MACDOFS980RU Exp Date: 12/31/2012 Tukwila Business License No.: BUS- 0100868 Valuation of Project (contractor's bid price): $ 15,000 Scope of Work (please provide detailed information): GAS PIPING FOR WORK TO REPLACE (3) PENTHOUSE BUILT UP UNITS WITH PACKAGED ROOF TOP AC UNITS. Building Use (per Int'1 Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water H:\Applications \Forms - Applications On Line \2011 Applications\Plumbing Permit Application Revised 8- 9.11.docx Revised: August 2011 bh Sewer Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen ( >750 gallon capacity) Each additional medical gas inlets /outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) 3 Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 3 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets 3 Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Intemational Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS • STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN OWN R OR AU RIZED A Signatures Date: 08/22/2012 Print Name: DARLA DOLL Day Telephone: (206) 768 -4278 Mailing Address: 7717 DETROIT AVE SW H:\Applications\Forms• Applications On Line \2011 Applications ' Plumbing Permit Application Revised 8 -9 -1 I.docx Revised: August 2011 bh SEATTLE WA 98106 City State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: PG12 -159 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 08/22/2012 Applicant: SOUTHCENTER MALL Issue Date: Receipt No.: R12 -02423 Initials: WER User ID: 1655 Payment Amount: $120.75 Payment Date: 08/22/2012 01:58 PM Balance: $0.00 Payee: MACDONALD MILLER FACITITY SOLUTIONS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3412 120.75 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES PLAN CHECK - NONRES 000.322.103.00.00 96.60 000.345.830 24.15 Total: $120.75 doc: Receiot -06 Printed: 08 -22 -2012 INSPECTION RECORD Retain a copy with permit Pall -153 INSPECTION NO. PERMIT NO. C CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 p_ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: TypeF --, Aic n: e , Address: ''/... ? u d 5 AA A-I i Date Called: Special Instructions: Date Wanted: ra.� 3 -e- /3 P.m. Requester: Phone No S7(- -3!71 Approved per applicable codes. El Corrections required prior to approval. 9 COMMENTS: ik nt eV k pJAAT7J) Inspector: n REINNSP ON FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: • .s_r �. _ #i INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670. Permit Inspection Request Line (206) 431 -2451 Project: t vt1c tg', e\A 101A t ( Type of Inspection: ct‘c, ice- ► ,3 CC,' C, Address: 2-S OU (1134- VA .0) 0 Date Called: Special Instructions: / Date Wanted:. CI-.I.3_l.Z a.m. m> Requester: • Phone No: 121/ per applicable codes. 0 Corrections required prior to approval. COMMENTS: (c) /( (L9r Z -( ) n) e7. f=F i fr L-TJ Ige-2( • Date: C REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.. 02 -01 -2013 DARLA DOLL 7717 DETROIT AV SW SEATTLE WA 98106 kz 3, z.,. epartment of aonimuni RE: Permit No. PG12 -159 WESTFIELD MALL - HVAC 2800 SOUTHCENTER MALL TUKW Dear Permit Holder: evelopmef t Rn laggertori lllayor Jacly .414cie 111ector In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 03/12/2013. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 03/12/2013, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. PG12 -159 :00 .e7 Boulevard late #;100 •. Tukwtla , Wasl%tngtori 9818E o`ne.;.?: 431 3670 •Fax =43T >5 PLAN PET EVI W G SLIP ACTIVITY NUMBER: PG12 -159' PROJECT NAME: WESTFIELD MALL - HVAC SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEP RTMENTS: B ilding ivision Public Works ❑ Fire Prevention Structural n n Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 08-23-12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 2 Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 09 -20 -12 Approved ❑ Approved with Conditions ki Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople inter Friendly Page • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with La=tl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MACDONALD /MILLER FAC SOL INC 2067684180 Po Box 47983 Seattle WA 98106 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602254260' Active MACDOFS980RU Construction Contractor 12/31/2002 12/31/2012 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVCOI *988RC DIVCO INCORPORATION Construction Contractor General Unused 12/3/2002 11/7/2012 Active LINFOAR980QG LINFORD AIR £t REFRIGERTN INC Construction Contractor General Unused 11/7/2002 11/7/2004 Archived ENCOMMS984CA ENCOMPASS MECHANICAL SERVICES Construction Contractor General Unused 2/1/2002 2/1/2004 Archived MACDOMR026RU MACDONALD MILLER RSDNTL INC Construction Contractor General Unused 12/31 /1998 12/31/2001 Archived DIVCOI *031L4 DIVCO INC Construction Contractor General Unused 6/24/1997 8/1/2003 Archived MACDOMR0760P MACDONALD MILLER RESIDENTIAL L Construction Contractor General Unused 9/17/1993 12/30/1998 Archived DIVCOEC188LC DIVCO ENERGY CONTROL COMPANY Construction Contractor General Unused 6/3/1982 5/26/1997 Archived MACDOM *248J9 MACDONALD MILLER CO Construction Contractor General Unused 4/29/1976 2/1/2002 Archived Business Owner Information Name Role Effective Date Expiration Date GOUGH, DAVID ANTHONY Director 12/29/2010 NOEL, STEPHANIE W Member 05/14/2010 SIMONDS, DERRICK R President 05/14/2010 WEBSTER, MARK E Vice President 05/14/2010 https://fortress.wa.gov/lni/bbip/Print.aspx 08/29/2012 J: \722 \5117 WF Southcenter Mall PH I Equip Rep1\ 00 \Eng \Dwg \SHTS \7225117TM0_01.dwg Thursday, July 05, 2012 8:42:20 r." DESCRIPTION SYMBOL DESCRIPTION BARE SHEETMETAL SOUNDLINE SHEETMETAL (1" LINING) 14/12 14/12 SL ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") CLEANROOM QUALITY DUCTWORK SHEETMETAL WRAPPED W/ INSULATION (2 ") 14/12 W BARE FLAT OVAL SHEETMETAL 14/120- BARE ROUND SHEETMETAL EXPOSED QUALITY SHEETMETAL EXAMPLE OF NEW 120 14/12 Q EXAMPLE OF DEMO 14/12 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") DUCTBOARD (1" FIBERGLASS) 14/12.e-W 14/12 DB EXAMPLE OF NOT IN CONTRACT (NIC) x x x x x x x x x x x x x x x x EXAMPLE OF EXISTING SYMBOL re F i UNIT 1 NOM GAS HEAT MBH UNIT NO. FAN OSA EER/ ELECTRICAL ELECTRICAL WT NOTES NO. I MFG & MODEL NO. I TONS INPUT OUTPUT CFM ESP HP CFM SEER IPLV VOLT /PH 1 MCA LBS NOTES RTU -1 TRANE YCH480B4 j 40.0 750 607 16600 j 1.5 15.0 4000 10.3 10.5 460/3 j 104 5700 NEW, 1 -7 RTU -6 j TRANE YCH600B4 50.0 750 607 19400 j 1.5 20.0 4900 10.3 10.5 460/3 125 6150 NEW, 1 -7 RTU -7 TRANE YCH600B4 50.0 750 607 19400 1 1.5 20.0 4900 10.3 10.5 460/3 125 6150 NEW, 1 -7 I DEMO, 1,2 NOTES: 1. DEMO EXISTING UNIT AND ASSOCIATED AIR HANDLING UNIT. 2. PROPERLY DISPOSE OF EXISTING UNIT AND REFRIGERANT. I i NOTES: 1. EC TO PROVIDE DISCONNECT AND REQUIRED POWERING WIRING. 2. FACTORY OPTIONS TO INCLUDE: - HIGH MODULATING GAS HEAT - HORIZONTAL SUPPLY AND RETURN - 100% POWER EXHAUST WITH STRATITRAC -2" MERV 8 HIGH EFFICIENCY, THROWAWAY FILTER - 0 -100% ECONOMIZER, REFERENCE ENTHALPY CONTROL W/ LOW LEAK FRESH AIR DAMPER - DISCHARGE TEMP CONTROL W/ VFD W/ BYPASS - SERVICE VALVES, VENTILATION OVERRIDE, HINGED SERVICE ACCESS, CONDENSER COIL GUARDS - LONTALK COMMUNICATION INTERFACE 3. FIELD TO INSTALL RETURN AIR SMOKE DETECTOR AND INTEGRATE TO SHUT DOWN UNIT UPON FIRE EVENT. 4. UNIT TO BE SUPPORTED PER STRUCTURAL ENGINEERS CALCS & DETAILS. 5. UNIT TO BE INTEGRATED WITH MALL ANDOVER CONTROLS. 6. PROVIDE ROOF CURB. ROOFING BY RAINER PACIFIC ROOFING 7. UNIT TO USE REDUCED AIRFLOW BASED ON SPACE THERMOSTAT HEATING AND COOLING DEMAND TO A MAXIMUM OF 75 PERCENT OF PEAK. DESCRIPTION SYMBOL DESCRIPTION BARE SHEETMETAL SOUNDLINE SHEETMETAL (1" LINING) 14/12 14/12 SL ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") CLEANROOM QUALITY DUCTWORK SHEETMETAL WRAPPED W/ INSULATION (2 ") 14/12 W BARE FLAT OVAL SHEETMETAL 14/120- BARE ROUND SHEETMETAL EXPOSED QUALITY SHEETMETAL EXAMPLE OF NEW 120 14/12 Q EXAMPLE OF DEMO 14/12 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") DUCTBOARD (1" FIBERGLASS) 14/12.e-W 14/12 DB EXAMPLE OF NOT IN CONTRACT (NIC) x x x x x x x x x x x x x x x x EXAMPLE OF EXISTING SYMBOL RTU -1, 2, & 3 - ROOFTOP PACKAGED GAS /ELECTRIC UNIT SERVES: MALL OPEN AREAS CONTROL TYPE: DDC SYSTEM SETPOINTS: MATCH EXISTING MALL SCHEDULES DDC SYSTEM INTERFACE: YES, SYSTEM TO INTERFACE WITH ANDOVER FRONT END. NOTES: UNITS TO OPERATE AS A SINGLE ZONE VAV WHICH WILL MODULATE THE FLOW TO PROVIDE UP TO 75% LESS AIR TO CONTROL HEATING AND COOLING TEMPERATURE. SUMMARY: UNITS TO OPERATE DURRING MALL OCCUPIED HOURS TO PROVIDE CONDITIONING AND OUT SIDE AIR TO MALL OPEN SPACE ECONOMIZER: UNIT SHALL BE EQUIPED WITH AN AIR SIDE ECONOMIER TO BE FIRST STAGE OF COOLING AND SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING. OPTIMUM START CONTROLS: UNITS SHALL BE EQUIPED WITH CONTROLS TO ADJUST THE START TIME OF THE UNIT TO BRING THE SPACE UP TO TEMPERATUER IMMEDIATELY BEFORE SCHEDULE OCCUPANCY. GAS HEAT: GAS HEAT SHALL BE FULLY MODULATING TO MAINTAIN A MINIMUM DISCHARGE TEMERPATURE OF 85 DEG F (USER ADJUSTABLE). DEMAND CONTROL VENTILATION: THE UNIT SHALL BE EQUIPED WITH A CO SENSOR WHICH WILL MODULATE THE SUPPLY CFM. SEQUENCE: OCCUPIED HOURS: RTU -1, 2, & 3 ON NON - OCCUPIED HOURS: RTU -1, 2, & 3 OFF DESCRIPTION - POWERED 1 1/2 HOUR FIRE /SMOKE DAMPER: LOW VELOCITY, VERTICAL OR HORIZONTAL, 3 -V BLADE,LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 212 OR EQUAL. 14/12 FLEX DUCT NOTES 1,2 FLEX CONNECTOR SYMBOL 1 1/ 2 H OU R FIRE/SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL OR HORIZONTAL, AIRFOIL BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 312 OR EQUAL. 3 HOUR FIRE /SMOKE DAMPER: LOW VELOCITY, VERTICAL OR HORIZONTAL, 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 231 OR EQUAL. 3 HOUR FIRE /SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL OR HORIZONTAL, AIR FOLD BLADE, LEAKAGE CLASS 1, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 311 OR EQUAL. 1 1/2 HOUR TUNNEL CORRIDOR FIRE /SMOKE DAMPER: LOW VELOCITY, 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK CFSD 212 -1 OR EQUAL. DESCRIPTION -NON POWERED 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL , 165° F FUSABLE LINK, BLADE IN AIR STREAM, GREENHECK DFD 150 TYPE A OR EQUAL. 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR STREAM , Q GREENHECK DFD 150 TYPE B ORE EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE IN AIR STREAM, GREENHECK DFD 350 TYPE A OR EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR STREAM, GREENHECK DFD 350 TYPE B OR EQUAL. 1 1/2 HOUR DYNAMIC FIRE DAMPER: LOW VELOCITY, NARROWLINE, VERTICAL - FOR INSTALLATION BETWEEN 2 TRANSFER GRILLES IN A WALL ASSEMBLY, 165° F FUSABLE LINK, GREENHECK DFD -110 OR EQUAL. 4\ BACKDRAFT DAMPER: GREENHECK WD 330 (VERT) OR WD -100 (HORIZONTAL) OR EQUAL. NOTES CEILING RADIATION DAMPER: GREENHECK CRD -2 OR EQUAL. 1 1/2 HOUR OUT OF WALL FIRE /SMOKE DAMPER: LOW VELOCITY, VERTICAL , 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK OF SD 212 OR EQUAL. BAROMETRIC RELIEF DAMPER: (.05 OPNG PRESSURE SHOWN) RUSKIN CBD2. NO SUBSTITUTE ALLOWED. I- VOLUME DAMPER: SHOP FABRICATED, W /LOCKING QUADRANT. SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. MOTORIZED CONTROL DAMPER -LOW VELOCITY GREENHECK VCD -23 OR EQUAL. MOTORIZED CONTROL DAMPER: MEDIUM VELOCITY AIRFOIL BLADES GREENHECK VCD -33 OR EQUAL. REVIEWED FOR CODE COMPLIANCE APPROVED SMOKE CONTROL MOTORIZED DAMPER: LOW VELOCITY GREENHECK SMD 202 OR EQUAL. AUG 29 2012 .0. SMOKE CONTROL MOTORIZED DAMPER: MEDIUM VELOCITY SCD -2 AIRFOIL BLADE GREENHECK SMD 301 OR EQUAL. City BLII! D!N Tn�<Ila �- DIVISION ABBV A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS FULL NAME COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ABBV ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM FULL NAME EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD- MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE -UP AIR NOMINAL ABBV OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP T'STAT TC TOD TOS TV TWG TWR TYP UNO VD VFD 0 FULL NAME OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical tTPlumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION . THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2009 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2009 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2009 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R -4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R -4.3 MIN.). AIR DUCT (R -4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2009 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE /SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2009 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2009 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE /SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. V AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AN F R S 0 S 9. G THE FLOOR OR WALL. 10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18 ". 12. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH ELECTRICAL CONTRACTOR. 13. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 14. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 15. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 16. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416. 17. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 18. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ( "MONOCOAT ") IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE 2009 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. - ALL DOORS MUST BE PROVIEDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE. 19. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS:10 CFM /S.F. GRAVITY DAMPERS: 20CFM /S.F. (40 CFM /S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 20. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. 21. RETURN AIR SHAFTS TO BE CONSTRUCTED BY THE G.C. TO WITHSTAND A MINIMUM 20 PSF DIFFERENTIAL PRESSURE ACROSS THE WALL. DIFFERENTIAL PRESSURE IS BASED UPON THE MAXIMUM STATIC PRESSURE CAPABILITY OF FAN SYSTEMS SUBJECT TO AUTOMATIC DAMPER CLOSURE. 22. PRESSURIZATION SHAFTS SHALL BE CONSTRUCTED BY THE G.C. AS FOLLOWS: - SHAFTS SERVED BY PRESSURIZATION FANS RATED UP TO 1" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 10 PSF DIFFERENTIAL PRESSURE. - SHAFTS SERVED BY PRESSURIZATION FANS RATED BETWEEN 1 -2.5" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 20 PSF DIFFERENTIAL PRESSURE. - FOR SHAFTS SERVED BY PRESSURIZATION FANS RATED ABOVE 2.5" STATIC 1RESSURE, CONTACT MECHANICAL ENGINEER. NAME TITLE REV DATE NAME TITLE REV DATE TM0.01 SCHEDULES & NOTES - HVAC TMO.SP SITE PLAN - HVAC TM2.03W WEST ROOF PLAN - HVAC TM2.03E EAST ROOF PLAN - HVAC TM4.01 -1 PENTHOUSE 1 SECTION & PARTIAL PLAN TM4.01 -6 PENTHOUSE 6 SECTION & PARTIAL PLAN TM4.01 -7 PENTHOUSE 7 SECTION & PARTIAL PLAN REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REPLACE 3 PENTHOUSE BUILT UP UNITS WITH PACKAGED ROOT TOP AC UNITS - t 4 P I P I t i 1 Qiv Ltj APN# 359700 -0245 LEGAL DESCRIPTION: INTERURBAN ADD TO SEATTLE POR OF NW 1/4 OF NE 1/4 OF SEC 26 & OF NE 1/4 OF NW 1/4 OF SEC 26 & OF SW 1/4 OF SE 1/4 OF SEC 23 & OF SE 1/4 OF SW 1/4 OF SEC 23 & OF INTERURBAN ADD TO SEATTLE & OF BROOKVALE GARDEN TRACTS & OF W H GILLIAM DONATION LAND CLAIM NO 40 - BEG SW COR OF SW 1/4 OF SE 1/4 OF SEC 23 TH N 89 -40 -24 W 217 FT TH N 0 -19 -36 E 150 FT TO TPOB TH S 89 -40 -24 E 151.60 FT TH N 0 -19 -36 E 72 FT TH S 89 -40 -24 E 406.80 FT TH S 0 -19 -36 W 182 FT TH S 89 -40 -24 E 179.20 FT TH N 0 -19 -36 E 366.84 FT TH S 87 -25 -13 E 253.52 FT TH N 0 -19 -36 E 208.77 FT TO BEG OF CURVE TO RGT 45 FT RAD TH ALG SD CURVE 45.96 FT TAP OF COMPOUND CURVE TH ALG CURVE TO RGT 122.35 FT RAD 63.68 FT TO SLY MGN OF TUKWILA PARKWAY TH S 88 -40 -00 W ALG SD SLY MGN 76.15 FT TO BEG OF CURVE TO RGT 1472.39 FT RAD TH ALG SD CURVE & SLY MGN 423.38 FT TH N 74 -51 -30 W 407.05 FT TO BEG OF CURVE TO LFT 552.62 FT RAD TH ALG SD CURVE & SLY MGN 185.63 FT TAP FR WCH THE TPOB BEARS S 0 -19 -36 W TH S 0 -19 -36 W 678.90 FT TO TPOB AKA PARCEL B OF CITY OF TUKWILA BDRY LN ADJ NO 87 -8 -BLA RECORDING NO 8712291101 FILE COPY Permit No., P7 I2H't Plan review approval is subject to errs and omissions. Approval of constriction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Copy and conditions is acknowledged: BY �. 9 Dater V24 /1Z City Of'Rukwila BUILDING DIVISION STRANDER BLVD VICINITY MAP NO SCALE RECEIVED AUG 2 2 2012 PERMIT CENTER 151 warm 1 1 1 N O N N C0 O K)<<- Co 07 (1) LL 0 0 cQ Z 0 J EXPIRES: 07 -06 -12 W 0 (1) Z 0 0! 0 ENGINEER: S AMANN CHECKED BY: B GEZON CAD: S HARGROVE DRAWING NUMBER: D -1240 -72251 SHEET NUMBER: z 0 I-- U z 0 U 0 LL 0 W LAST REVISED: 07 -02 -12 DATE PLOTTED: 07 -02 -12 ISSUE DATE: 07 -02 -12 17 -00 TM0.01 ) 4 Aa- 4 UNIT NO. MFG & MODEL NO. NOM COOL TONS EER/ SEER ELECTRICAL CONTROL WT LBS NOTES VOLT /PH FLA CU -1 TRANE CA -4008 40 208/3 13.4 - 1540 DEMO, 1,2 CU -6A TRANE CA -3008 30 208/3 8.6 1250 DEMO, 1,2 CU -6B TRANE CA -3008 30 208/3 8.6 1250 DEMO, 1,2 CU -7A TRANE CA -3008 30 208/3 8.6 1250 DEMO, 1,2 CU -7B TRANE CA -3008 30 208/3 8.6 1250 DEMO, 1,2 NOTES: 1. DEMO EXISTING UNIT AND ASSOCIATED AIR HANDLING UNIT. 2. PROPERLY DISPOSE OF EXISTING UNIT AND REFRIGERANT. RTU -1, 2, & 3 - ROOFTOP PACKAGED GAS /ELECTRIC UNIT SERVES: MALL OPEN AREAS CONTROL TYPE: DDC SYSTEM SETPOINTS: MATCH EXISTING MALL SCHEDULES DDC SYSTEM INTERFACE: YES, SYSTEM TO INTERFACE WITH ANDOVER FRONT END. NOTES: UNITS TO OPERATE AS A SINGLE ZONE VAV WHICH WILL MODULATE THE FLOW TO PROVIDE UP TO 75% LESS AIR TO CONTROL HEATING AND COOLING TEMPERATURE. SUMMARY: UNITS TO OPERATE DURRING MALL OCCUPIED HOURS TO PROVIDE CONDITIONING AND OUT SIDE AIR TO MALL OPEN SPACE ECONOMIZER: UNIT SHALL BE EQUIPED WITH AN AIR SIDE ECONOMIER TO BE FIRST STAGE OF COOLING AND SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING. OPTIMUM START CONTROLS: UNITS SHALL BE EQUIPED WITH CONTROLS TO ADJUST THE START TIME OF THE UNIT TO BRING THE SPACE UP TO TEMPERATUER IMMEDIATELY BEFORE SCHEDULE OCCUPANCY. GAS HEAT: GAS HEAT SHALL BE FULLY MODULATING TO MAINTAIN A MINIMUM DISCHARGE TEMERPATURE OF 85 DEG F (USER ADJUSTABLE). DEMAND CONTROL VENTILATION: THE UNIT SHALL BE EQUIPED WITH A CO SENSOR WHICH WILL MODULATE THE SUPPLY CFM. SEQUENCE: OCCUPIED HOURS: RTU -1, 2, & 3 ON NON - OCCUPIED HOURS: RTU -1, 2, & 3 OFF DESCRIPTION - POWERED 1 1/2 HOUR FIRE /SMOKE DAMPER: LOW VELOCITY, VERTICAL OR HORIZONTAL, 3 -V BLADE,LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 212 OR EQUAL. 14/12 FLEX DUCT NOTES 1,2 FLEX CONNECTOR SYMBOL 1 1/ 2 H OU R FIRE/SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL OR HORIZONTAL, AIRFOIL BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 312 OR EQUAL. 3 HOUR FIRE /SMOKE DAMPER: LOW VELOCITY, VERTICAL OR HORIZONTAL, 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 231 OR EQUAL. 3 HOUR FIRE /SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL OR HORIZONTAL, AIR FOLD BLADE, LEAKAGE CLASS 1, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 311 OR EQUAL. 1 1/2 HOUR TUNNEL CORRIDOR FIRE /SMOKE DAMPER: LOW VELOCITY, 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK CFSD 212 -1 OR EQUAL. DESCRIPTION -NON POWERED 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL , 165° F FUSABLE LINK, BLADE IN AIR STREAM, GREENHECK DFD 150 TYPE A OR EQUAL. 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR STREAM , Q GREENHECK DFD 150 TYPE B ORE EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE IN AIR STREAM, GREENHECK DFD 350 TYPE A OR EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR STREAM, GREENHECK DFD 350 TYPE B OR EQUAL. 1 1/2 HOUR DYNAMIC FIRE DAMPER: LOW VELOCITY, NARROWLINE, VERTICAL - FOR INSTALLATION BETWEEN 2 TRANSFER GRILLES IN A WALL ASSEMBLY, 165° F FUSABLE LINK, GREENHECK DFD -110 OR EQUAL. 4\ BACKDRAFT DAMPER: GREENHECK WD 330 (VERT) OR WD -100 (HORIZONTAL) OR EQUAL. NOTES CEILING RADIATION DAMPER: GREENHECK CRD -2 OR EQUAL. 1 1/2 HOUR OUT OF WALL FIRE /SMOKE DAMPER: LOW VELOCITY, VERTICAL , 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK OF SD 212 OR EQUAL. BAROMETRIC RELIEF DAMPER: (.05 OPNG PRESSURE SHOWN) RUSKIN CBD2. NO SUBSTITUTE ALLOWED. I- VOLUME DAMPER: SHOP FABRICATED, W /LOCKING QUADRANT. SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. MOTORIZED CONTROL DAMPER -LOW VELOCITY GREENHECK VCD -23 OR EQUAL. MOTORIZED CONTROL DAMPER: MEDIUM VELOCITY AIRFOIL BLADES GREENHECK VCD -33 OR EQUAL. REVIEWED FOR CODE COMPLIANCE APPROVED SMOKE CONTROL MOTORIZED DAMPER: LOW VELOCITY GREENHECK SMD 202 OR EQUAL. AUG 29 2012 .0. SMOKE CONTROL MOTORIZED DAMPER: MEDIUM VELOCITY SCD -2 AIRFOIL BLADE GREENHECK SMD 301 OR EQUAL. City BLII! D!N Tn�<Ila �- DIVISION ABBV A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS FULL NAME COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ABBV ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM FULL NAME EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD- MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE -UP AIR NOMINAL ABBV OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP T'STAT TC TOD TOS TV TWG TWR TYP UNO VD VFD 0 FULL NAME OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical tTPlumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION . THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2009 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2009 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2009 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R -4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R -4.3 MIN.). AIR DUCT (R -4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2009 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE /SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2009 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2009 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE /SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. V AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AN F R S 0 S 9. G THE FLOOR OR WALL. 10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18 ". 12. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH ELECTRICAL CONTRACTOR. 13. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 14. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 15. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 16. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416. 17. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 18. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ( "MONOCOAT ") IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE 2009 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. - ALL DOORS MUST BE PROVIEDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE. 19. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS:10 CFM /S.F. GRAVITY DAMPERS: 20CFM /S.F. (40 CFM /S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 20. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. 21. RETURN AIR SHAFTS TO BE CONSTRUCTED BY THE G.C. TO WITHSTAND A MINIMUM 20 PSF DIFFERENTIAL PRESSURE ACROSS THE WALL. DIFFERENTIAL PRESSURE IS BASED UPON THE MAXIMUM STATIC PRESSURE CAPABILITY OF FAN SYSTEMS SUBJECT TO AUTOMATIC DAMPER CLOSURE. 22. PRESSURIZATION SHAFTS SHALL BE CONSTRUCTED BY THE G.C. AS FOLLOWS: - SHAFTS SERVED BY PRESSURIZATION FANS RATED UP TO 1" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 10 PSF DIFFERENTIAL PRESSURE. - SHAFTS SERVED BY PRESSURIZATION FANS RATED BETWEEN 1 -2.5" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 20 PSF DIFFERENTIAL PRESSURE. - FOR SHAFTS SERVED BY PRESSURIZATION FANS RATED ABOVE 2.5" STATIC 1RESSURE, CONTACT MECHANICAL ENGINEER. NAME TITLE REV DATE NAME TITLE REV DATE TM0.01 SCHEDULES & NOTES - HVAC TMO.SP SITE PLAN - HVAC TM2.03W WEST ROOF PLAN - HVAC TM2.03E EAST ROOF PLAN - HVAC TM4.01 -1 PENTHOUSE 1 SECTION & PARTIAL PLAN TM4.01 -6 PENTHOUSE 6 SECTION & PARTIAL PLAN TM4.01 -7 PENTHOUSE 7 SECTION & PARTIAL PLAN REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REPLACE 3 PENTHOUSE BUILT UP UNITS WITH PACKAGED ROOT TOP AC UNITS - t 4 P I P I t i 1 Qiv Ltj APN# 359700 -0245 LEGAL DESCRIPTION: INTERURBAN ADD TO SEATTLE POR OF NW 1/4 OF NE 1/4 OF SEC 26 & OF NE 1/4 OF NW 1/4 OF SEC 26 & OF SW 1/4 OF SE 1/4 OF SEC 23 & OF SE 1/4 OF SW 1/4 OF SEC 23 & OF INTERURBAN ADD TO SEATTLE & OF BROOKVALE GARDEN TRACTS & OF W H GILLIAM DONATION LAND CLAIM NO 40 - BEG SW COR OF SW 1/4 OF SE 1/4 OF SEC 23 TH N 89 -40 -24 W 217 FT TH N 0 -19 -36 E 150 FT TO TPOB TH S 89 -40 -24 E 151.60 FT TH N 0 -19 -36 E 72 FT TH S 89 -40 -24 E 406.80 FT TH S 0 -19 -36 W 182 FT TH S 89 -40 -24 E 179.20 FT TH N 0 -19 -36 E 366.84 FT TH S 87 -25 -13 E 253.52 FT TH N 0 -19 -36 E 208.77 FT TO BEG OF CURVE TO RGT 45 FT RAD TH ALG SD CURVE 45.96 FT TAP OF COMPOUND CURVE TH ALG CURVE TO RGT 122.35 FT RAD 63.68 FT TO SLY MGN OF TUKWILA PARKWAY TH S 88 -40 -00 W ALG SD SLY MGN 76.15 FT TO BEG OF CURVE TO RGT 1472.39 FT RAD TH ALG SD CURVE & SLY MGN 423.38 FT TH N 74 -51 -30 W 407.05 FT TO BEG OF CURVE TO LFT 552.62 FT RAD TH ALG SD CURVE & SLY MGN 185.63 FT TAP FR WCH THE TPOB BEARS S 0 -19 -36 W TH S 0 -19 -36 W 678.90 FT TO TPOB AKA PARCEL B OF CITY OF TUKWILA BDRY LN ADJ NO 87 -8 -BLA RECORDING NO 8712291101 FILE COPY Permit No., P7 I2H't Plan review approval is subject to errs and omissions. Approval of constriction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Copy and conditions is acknowledged: BY �. 9 Dater V24 /1Z City Of'Rukwila BUILDING DIVISION STRANDER BLVD VICINITY MAP NO SCALE RECEIVED AUG 2 2 2012 PERMIT CENTER 151 warm 1 1 1 N O N N C0 O K)<<- Co 07 (1) LL 0 0 cQ Z 0 J EXPIRES: 07 -06 -12 W 0 (1) Z 0 0! 0 ENGINEER: S AMANN CHECKED BY: B GEZON CAD: S HARGROVE DRAWING NUMBER: D -1240 -72251 SHEET NUMBER: z 0 I-- U z 0 U 0 LL 0 W LAST REVISED: 07 -02 -12 DATE PLOTTED: 07 -02 -12 ISSUE DATE: 07 -02 -12 17 -00 TM0.01 Thursday, July 05, 2012 8:42:38 0) acDonald -Mi c%-(Citp ti N- rn ' N- co 26°N- :1 (f) U_ U) 0 c6 C A < o co o 0 0 Na I I I l F- Z w w U w Za w U_Z w 0 —� C3g J w _W ‘- w =. (1)QO wIg O N WA Lic No: MACDOFS980RU EXPIRES: 07 -06 -12 w 0 REVISIONS: .- -11 1' 11 w I I I I- N N r 0 N co CD 0 0 0 ‹i< REVISIONS: Z 0 F- U L.L F z 0 U LL 0 U 0 w C!) C!) ENGINEER: LAST REVISED: S HARGROVE 07 -02 -12 CHECKED BY: DATE PLOTTED: B GEZON 07 -02 -12 CAD: ISSUE DATE: S HARGROVE 07 -02 -12 DRAWING NUMBER: D-1240-7225117-00 SHEET NUMBER: TM2.03E } (4-2) X431 z 44 1 1 45 f I 46 47 ' J (4_!1 , 0 ' 51 152� I 53 54 I 55 ` ju 5 ervy { 57 [[ _ vFLS 58 r fr (59) ,Iv , 60 0 62 5,, D -6 5 D -6- 5" D -6� 5 D -6' 5 D- - -6r-f t i 5 " D -6./ ,» .� D -6 sl � I _....- 'PR %RI —12 PR /RH_ 1 ( PR /E -3 » V. .R. 0-- 4" lr BLOCK DETAIL I� ROOF PENEf 2 V I .R. ® / PR /RH -1 WED ,- 2 1 V.T.R. _ . - • E-Qlth EXPAN. •JOINT I . 1 _ 'EQUIP _ .PAD' I - °' V.T.R. \_3,f V.T.R. ��✓✓ ) NM At METER 87.2 la RTU -6 GAS i Il O MN NI i `�,• NI M 25 ABM la ,ETER � `- — ! PENTHOU' E N0.6 SEE DWG. TM4.01 -6 (I I I PENTHOUSE SEE DWG. NO.7 4.01 -7 RTU -7 E -12 1111 1.:._/;�� » D- • ✓ _.. C 3:- 6 [jJj7 1_ w� ri v1 r I I E IlI ■ /W ►.0 rev ma ■ it — 3" \ /.T.'+ �o `� ,Ir'1f ;4r SD BLOCK I �c+ MB If" al- -1, V.T.R. -Ir 1r �3" RELIEF HOrD SEE DET. YP. BLOCK 4u „w. R IE WED FOR CODE COMPLIANCE P APPROVED 1 M -2- \ E PR /REi -13 Q--- -` ' V.T.R. H -3I a EXPAN. f JOINT 6 PIPE AUG 2 9 2012 % M -28 SUPPORT \ (TYPICAL) E tR` M8H. PIP Willik . i1111111111111111 Cite of'%k Tukwila BUILDING DIVISION s r 5° SUPPORT to -25) (TYPICAL} __-, ”" �J #) c� PR/ r 6 21 , 22 0 ..!: 1 : a EQUIP - PAD - .1 • 1 - DETAIL ROOF ROOF -- PE ( ET. 0 a 1 1 -.. EQUI.' - PAD - DETAIL- ROOF P: _ FY-15 ( ET. r 31 S l"J Y r�� t I� 5" .T. R:7 `R `E -5 0 wit /'j-2" TR 3 V.T.R. 1 i , I D-16 t Val MEF . �lii� ..J ..��_ � 1���'©� t IC -1i 11 5'' D- 6 M •fie 6 t I , �_� -� ff � D -� 'r" -� -16 `A - t�k ii pi Pl t t EI III1 MEC1. AREA ,f �- I; IrS PiEt S . Pli c IJOIN1 1 y Ub W S (,P k f tvs - p f1 (� 11101 I � 11110111101111. -1F _ �:� Ak;;; 1 LAC Et, LE‘ ` I I I NEARMI '.A.I. 5" C} -6 .I / lily) zz. (TYPICAL, 9 / \ _ E - =n _EVE _C 8 SHEMpit, _........._ ,..._.._!.r I 16 M v t r - T.R. . Il I 5, �� D L I: ° RfRN 1 41 1 ' D, A i I O a 1 s iT i C s i I MIN ,11 - ; I, Ir 11 :_ �� PR* : T S� " AGE Ill w` L__._ L ,_ - EC-Hal-1'1 ` ITS., -_" - IF ° MECH. NIT , � AC-12 _s IL r � D� JI - I. .... I T ARO I MAC -10 I��o ��� ` inn o . _._ .... 3EC H. U 1 t�REA a 11 Iiillik I FC1 R OFi9P EQUI"FAE (BYO S, is 12 F TU- FC2 ` ROOFTOP EQU El I. P) ".I1'' Q 11' it I ( I LAC -2G _ / ail r 9. C. _._. -_ _-.... r -. _ 1W. c, _... �E `12 _._ ,. ��` EXISTING �` �l 9rT�: E - / 4 _ �� "� 1►II� r � �` .. - ,,, OCATE IN � T 4.- °E�iT ���11 LAC -1G "C Taw, FC2 F'C i i I- L OTHERS, FLITURErf03 ROOFTOP EQUIPMENT (BY OTHERS 1 ) RANT TYP) 8 2/ A Al B C D — U , ..., . ,. — N / P°ROVIt R: €4 10" EXHA T AT ROOF , " ID PA DO N± to -"I .�.. §, eUCT TERMI AP. ROOF CHID BY 0 •",f'..-' ATION�� UTTING HERS, - ■ \ \\ -� f '1.,. � ef 2012 , ROOF PARKING / ( 3 Main `tE .l E TYP) I SAW CUT T TERM, ■ - t `, 1 \ 1 FHTIfRE F4 I ROOFTOP E. (BY OTHERS, EF-6 E AN .. �� a I 1 E �`"� -- I ] r'. 1 1►' , "---- 1 • .:�` S { o x IA ` ST el , o{ i _m._ °_ #._1 5 Y ` FC4 a J 1 �� A) 6 4),N, qb isq 7 �� 0 Z .i, C ®� R ..1 _I LAC -1H , '� RS AND RL A ' `= FC5 ax LAC -2H i EF -4 -� EF -33 / ■ Ii , _. ° \ I t►� �'., r� -M11111.�'i _ - '� 510 +fir �i© MAC -11 i Z CI i el RECEIVED �, EF -31 =:�_�i — — - ! 1 a LOWER ,\ �- ` © AUG 2 2 R3 EF -7 f r... o PERMIT CENTER - � MAC -8 R3 RR� F m I 0 0 M 0 ® ll 0 lJ ZO 21 Z3 0 0 ir1^ 1/16" = 1' -0" 0) acDonald -Mi c%-(Citp ti N- rn ' N- co 26°N- :1 (f) U_ U) 0 c6 C A < o co o 0 0 Na I I I l F- Z w w U w Za w U_Z w 0 —� C3g J w _W ‘- w =. (1)QO wIg O N WA Lic No: MACDOFS980RU EXPIRES: 07 -06 -12 w 0 REVISIONS: .- -11 1' 11 w I I I I- N N r 0 N co CD 0 0 0 ‹i< REVISIONS: Z 0 F- U L.L F z 0 U LL 0 U 0 w C!) C!) ENGINEER: LAST REVISED: S HARGROVE 07 -02 -12 CHECKED BY: DATE PLOTTED: B GEZON 07 -02 -12 CAD: ISSUE DATE: S HARGROVE 07 -02 -12 DRAWING NUMBER: D-1240-7225117-00 SHEET NUMBER: TM2.03E 13 15 (16 ( 17 ;1 .19 , M-25) 5" 0-6 1. DETAIL ROOF PENETRA D -6-. " .EQUIP: — PAD. I I .I . ETAI L. EXPAN. t JOINT URE BLOCK BLOCK A 6" EY PAN. JOINT RELIEF H TYPICAL 9 3 4� 39 040 DETAIL PFN 'EOUtP — _PAD • BLOCK ®T.R. PR /RH -2) V.T.R, DETAL EXPANSIO I s J-I RELIEF 3" D -11 " V.T.R.- PENTHOU' SEE DWG. LI OLLMN ONTR. T CI SS C4 'XX TO OR AST Y GENL. CO TR. SET ROOF DRAIN NNECTION TO D.S. I BLOCK PR /RH -2 PR /RH -3 a 0 07 rii N 0 N 0 0 I- (R) qR /E -1 —4" VTR 0 5" D -6 PR /RH -1 'E11 RELIEF HOOD BLOCK 6 1 FIR SU (Tr PORT ICAL) VE BY CAS TO METE G RD 496 MBH 0 T TO XXX GENL, CON CORRIDOR F. AST IN T MEN F XX X VTR. V.T.R. PENTHO SEE DW SE NO.4 . M -22 PR /RH -81 0 PR /RH -6 t-R /RH- DE AIL DETAIL GAS METER 932. MBH THOUSE No.1 DWG TM4.11 DETAIL OOF PEN 'PAN. INT DETAIL ROOF P ?.UIP. _ Al) • " V.T.R V.T.R. — DETAIL '.T.R. V.T.R. PR /E -8 3" 0 -6 6" D -6 111 I III 1111 III m V IIII IIIIIo IA, X. ,N. JOI T -55D -6 •MEC ARE PR RH -4 DETAIL ROOF P EI III 'HOW NI fI f iii • - EQUIP- — _.,PAD'_'._ PENTHO SEE DW CONCRETE t'ALKWAY ,W 0 PIPE 3 ER MBH SUPPORT (TYPICAL) BLOCK 5" 0-6 EQUIP ROOF NO.9 MAC -10 FUTURE BLOCK ROO P_AN - -W SCAL: 1 /32 " =1 ' —O" -s PLENU 42x36 3000 TO °■iuii111111 E:. 1 M1= ROOF PARKING F(UT ROOFTOP EQU (ELY OTHERS, FUTURI /F�C3 NA ROOFTOP EQUIPME (UY OTHERS, 1 P) 0 FC2 FC31 9 (2 TYP) 12'0 TYPE VENT DN MAC -9 I' I -32 5ie MAC -7E Tt1'P A THERS, TYP CONCRETE RS ANC RL DN- 2335 LAC -21 FUTURE DUCT ROUT PEN T ACE RE '1 TENANT EF -30 ON ROOF BO I FU RE FC R• 0 BY OTHERS, TYP) FUTURE FC5 TENANT ROOFTOP EQUIPMENT (BY' OTHERS, TYP) FUTURE R3 TENANT ROOFTOP EQUIPMENT (B`OTHERS TYP LOV4 IOPEi TERRA REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2012 City of Tukwila BUILDING DIVISION 4 0 0� ✓ ti CO CO • CO N ALL ® 7 o 0 air" 0) ▪ Q� . I 00 ▪ (V O N r 0 N- 0 www.macmiller.com I N O N O X-1159 RECEIVED AUG 2 2 2012 PERMIT CENTER I I I 1/32" = 1' -0" NI N N co O REVIEW SET Ir N 1) I O REVIEW SET <1<- WA Lic No: MACDOFS980RU EXPIRES: 07 -06 -12 w Q 0 REVISIONS: REVISIONS: ENGINEER: LAST REVISED: S HARGROVE 07-02-12 CHECKED BY: B GEZON DATE PLOTTED: 07 -02 -12 CAD: ISSUE DATE: S HARGROVE 07-02-12 DRAWING NUMBER: D-1240-7225117-00 SHEET NUMBER: TM2.03W I I i 1 2 1 23/1 2 ,, ? j t. 2 , I ) " VTR 3 VTR „ L D -6 mf g E'w 1 d -�kl y'jyi r pti. :YS..i A� � ra, h ; -* ,:, +I I _. _:' BLOCK EXISTING BON ivi, RCHE BLOCK 6 . ; Q C.W. MAKE —UP CAP AFTER 1ST VALVE PROVIDE RA SMOKE DETECTOR AND INTERLOCK WITH RTU -1 TO SHUTDOWN UPON A FIRE EVENT A TM4.01- 40x40SL(2 ") SEE DWG M -8 FOR CONTINUATION 18"x16" LOUVER & BIRD SCREEN BY GEN'L. CONTR. (BOT. OF LOUVER 2' -0 ABV. ROOF) c'1 J 0 x 0 DUCT AND UNIT SUPPORT STEEL TO BE HOT DIPPED GALVINIZED. r i 52x66SL(2 ") 40x4OSL(2 ") (PR /R -1 2x66SL(2 ") RTU -1 I 10 I DEMO GAS LINE FROM BOILER AT METER & REROUTE TO RTU -1. FIELD TO CONFIRM N -GAS LINE DOES NOT SERVE OTHER EQUIPMENT. PENT GUS SCALE 1/4 " =1' -0" 1-1/2" NGAS #1 PLAN ESTIMATED ROOF SLOPE UP BEGINS SEE STRUCTURAL DRAWINGS FOR ROOF CONNECTION DETAILS 30/24" A FIELD TO DETERMINE EXACT POC TO EXISTING RA DUCT 16'- 0 "x2' -0" R.A. GRILLE TYPE D FIELD TO DETERMINE EXACT POC TO (E) SA DUCT AND REQUIRED DUCT SIZE. Al B REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2012 City of Tukwila BUILDING DIVISION A L 4•- MALL SYSTEM #1 Al x68SL( SP ROOF --- 24/84 TEST HOLES (TYP.) V. DPR. Ox8OSL(2") H 0 1_ J Hi G2 KEY PLAN G1 F 2'x6'x16' PLENUM SECTION A —A SCALE Ya " =1' —O" .2'-0"x l C-0" R.A. GRILLE TYPE D P61.) 159 Thursday, July 05, 2012 8:42:44 AM RECEIVED AUG 2 2 2012 PERMIT CENTER 4 L a) z -6 —2 CO 0 0 co 0 U CO CO O co - co O co Qj O rIZS CD - N V) LPL O 7 O C Q O °o � N - O 1*-- • d E U U) E C) CO E F- z w w 0 wa_ w Z p: V = W Z D 2 ri VJ D 0 Jw w N1 N 0 0 N1 N N m 0 REVIEW SET REVIEW SET a tY a. ce co w co Z� ▪ w= r Q V/ <Q_ w TTom§ 0- NI- z 0 z WA Lic No: MACDOFS980RU EXPIRES: 07 -06 -12 w 0 REVISIONS: ENGINEER: S HARGROVE CHECKED BY: B GEZON CAD: S HARGROVE DRAWING NUMBER: D -1240 -72251 SHEET NUMBER: 0 REVISIONS: z 0 F- U vJ z 0 0 0 U- 0 w '() 0) LAST REVISED: 07 -02 -12 DATE PLOTTED: 07 -02 -12 ISSUE DATE: 07 -02 -12 17 -00 TM4.01 -1 T H- ■ PROVIDE it VENT FAN LEG STAND .� ( PR.t E -D 1 68x26SL(2) 84/24" , , .---'-' ' : 1', s / 5 pct.' AD 80x2OSL( 7' ,� ^- ,— "1 40x4OSL(2 ") V: DPR / , r 30424" , +' .. 40x40SL(2 ") .'' "1f'. DPR 30; 24" 1 ' 20/24' I _ J . to V. DPR / t INSTRUMENT TEST HOLE (lYP.) BLOCK OFF LOUVER OPENING. PROVIDE 16X16 LOUVER IN FILLED IN AREA -1 a c'1 J 0 x 0 DUCT AND UNIT SUPPORT STEEL TO BE HOT DIPPED GALVINIZED. r i 52x66SL(2 ") 40x4OSL(2 ") (PR /R -1 2x66SL(2 ") RTU -1 I 10 I DEMO GAS LINE FROM BOILER AT METER & REROUTE TO RTU -1. FIELD TO CONFIRM N -GAS LINE DOES NOT SERVE OTHER EQUIPMENT. PENT GUS SCALE 1/4 " =1' -0" 1-1/2" NGAS #1 PLAN ESTIMATED ROOF SLOPE UP BEGINS SEE STRUCTURAL DRAWINGS FOR ROOF CONNECTION DETAILS 30/24" A FIELD TO DETERMINE EXACT POC TO EXISTING RA DUCT 16'- 0 "x2' -0" R.A. GRILLE TYPE D FIELD TO DETERMINE EXACT POC TO (E) SA DUCT AND REQUIRED DUCT SIZE. Al B REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2012 City of Tukwila BUILDING DIVISION A L 4•- MALL SYSTEM #1 Al x68SL( SP ROOF --- 24/84 TEST HOLES (TYP.) V. DPR. Ox8OSL(2") H 0 1_ J Hi G2 KEY PLAN G1 F 2'x6'x16' PLENUM SECTION A —A SCALE Ya " =1' —O" .2'-0"x l C-0" R.A. GRILLE TYPE D P61.) 159 Thursday, July 05, 2012 8:42:44 AM RECEIVED AUG 2 2 2012 PERMIT CENTER 4 L a) z -6 —2 CO 0 0 co 0 U CO CO O co - co O co Qj O rIZS CD - N V) LPL O 7 O C Q O °o � N - O 1*-- • d E U U) E C) CO E F- z w w 0 wa_ w Z p: V = W Z D 2 ri VJ D 0 Jw w N1 N 0 0 N1 N N m 0 REVIEW SET REVIEW SET a tY a. ce co w co Z� ▪ w= r Q V/ <Q_ w TTom§ 0- NI- z 0 z WA Lic No: MACDOFS980RU EXPIRES: 07 -06 -12 w 0 REVISIONS: ENGINEER: S HARGROVE CHECKED BY: B GEZON CAD: S HARGROVE DRAWING NUMBER: D -1240 -72251 SHEET NUMBER: 0 REVISIONS: z 0 F- U vJ z 0 0 0 U- 0 w '() 0) LAST REVISED: 07 -02 -12 DATE PLOTTED: 07 -02 -12 ISSUE DATE: 07 -02 -12 17 -00 TM4.01 -1 FILL LOUVER OPENING. PROVIDE 16X16 LOUVER IN FILLED IN AREA PROVIDE MINIMUM 6" FLEX AT GRID LINE 46 FOR EARTHQUAKE JOINT 4 SEE STRUCTURAL DRAWINGS FO ROOF CONNECTION DETAILS RTU -6 52x66SL(2 ") 50x32SL(� x5OSL(2 ") O 3"V. TR 3" D -4 Ii!!01 III j masse 6" EARTHQUAKE JOINT N J N x O FIELD TO DETERMINE EXACT POC TO EXISTING RA DUCT SIZE CAP AT WALL 84/28 TO 96/24 34/28" J d- N X V V.PR V PROVIDE 24" FLEX W/ U —SHAPE IN N —GAS LINE FOR EARTHQUAKE JOINT N ! • v . " ' LEX DUCT AND UNIT SUPPORT STEEL TO BE HOT DIPPED GALVINIZED. LINE 46 FOR EARTHQUAKE JOINT PROVIDE RA SMOKE DETECTOR AND INTERLOCK WITH RTU -6 TO SHUTDOWN UPON A FIRE EVENT VENT FAN FIELD TO DEMO & REPLACE ELBOW AND DETERMINE EXACT POC AND DUCT SIZE. EARTHQUAKE JOINT Alit r--` / 12" LG. FLEX. DUCT ✓ 6"LOUVERS t (31R D SCREEN BY AWEGEN. CONTR. I! I� 2 FOR CO \'T SEE DWG. M- UATION S 20/24" RECIRC, PLENUM BELOW 28/24" 18'- 0 „x2' -0” RECIRC GRILLE TYPE D PLNTH M4.01— CJSF No -6 PLAN SCALE 1A"=1 -0" REVIEWED FOR ,� CODE COMPLIANCE.' APPROVED la 29 2012 City of Tu ll BUILDIN I S` 18 "x16" LOUVER BIRD _m SCREEN BY GEN' CONTR. F.A.I. 2..x8osL(2 ") 24.m. I 28/84" 45/84" 28 2.'-0"x18'-0" REC1RC, GRILLE TYPE D 2' -0 —6 "x18' —O" PLEN \V.DPI; MP.) PR /E —g 32x50 L(2 ") — RECIRC. PLENUM. CEIL LINE ION A -A SCALE 1A " =1' -O" H G MALL SYS M J16 G1 G s � 4 L- W co co o� co co co O 0 O X N U) LL • o 3 0 C 0) N > CC) CNI 0 O 0 O • 0 E U E RECEIVED AUG 222012 PERMIT CENTER EXPIRES: 07 -06 -12 Iii 0 REVISIONS: 1 1 1 1 1 I , — �I �I I I N N In O N r 0 I I I I-- co co 0 0 F- Z CtW W U W a_ 77 �W// Z LL U W al VJ D p0 g. _all LT, co ao L rZ o u_ j o < (tea Qo� wI W cL N I- a- cti F —' e REVISIONS: Z O F- 0 LL vJ Z 0 U 0 LL 0 W VJ ENGINEER: LAST REVISED: S HARGROVE 07 -02 -12 CHECKED BY: DATE PLOTTED: B GEZON 07 -02 -12 CAD: ISSUE DATE: S HARGROVE 07 -02 -12 DRAWING NUMBER: D-1240-7225117-00 SHEET NUMBER: TM4.01 -6 PROVIDE RA SMOKE DETECTOR AND INTERLOCK WITH RTU -7 TO SHUTDOWN UPON A FIRE EVENT TAP • GAS •LINE • FROM 'BOILER AT METER &• REROUTE * TO • ITU -7. FIELD TO CONFIRM. N -GAS DOES NOT SERVE •OTHER• EQUIPMENT: { 52 76x�28SL(2 ") SEE STRUCTURAL DRAWINGS FOR ROOF CONNECTION DETAILS - - - - - ESTIMATED ROOF SLOPE UP BEGINS% Thursday, July 05, 2012 8:42:54 AM FIELD TO DETERMINE EXACT POC TO — (E) SA DUCT AND REQUIRED DUCT SIZE VENT FAN CPR /E -9J (FLT. MTD.) 18x16 LVR. & BIRDSCREEN BY GEN. CONTR. DUCT AND UNIT SUPPORT STEEL TO BE HOT DIPPED GALVINIZED. • • 1 • ( 53~ FILL UNUSED PORTION OF LOUVER AREA. PROVIDE 16X16 LOUVER IN FILLED IN AREA CAP LINE RECIRC. PLENUM BELOW CO -CPAs At.:6PR,2091-427.2. FOR city of Tukwila DIN' DI.._... 18'- 0 "x2' -0" RECIRC. GRILLE TYPE D A PENT 68/26" C M24 D (AP AT WALL FIELD TO DETERMINE EXACT POC TO EXISTING RA DUCT SEE SHT M -14 FOR CONT. \TA, 28/15" F.V. DPR 63/26" TURNING VANES CENTER BETWEEN GRID LINES 53 &54 OUSE #7 PLAN f. 48 12 F.V. DPR C 48x12" TR 2000. CFM (SEE DWG. M -14) SCALE Y" =1' -0" SEE SI-IT M -14 FOR CONTINUATION `s 5 • CO Cr) 0 h N- 0 CO CAD ti CO • N to co u_ O W O C � N- T) o 4) C D j 0 • .0 N- 0 CD 00 CT) 0 LL O 0 U Q g. 2 • Z J 66 S �—,— 28/80" 18 "x16" L SCREEN 6 ■ F.A.I. LOUV ' R & BIRD - GI NL. CONTR. 38x54SL(2 ") 68/26" FILL UNUSED PORTION OF LOUVER AREA. V. DPR. (TYP.) PR /E -9 PLEf1U SECTION A -A SCALE 1/4 " =1' -0" 2' -0 "x18' -0" RECIRC. GRILLE TYPE D PG 151 MALL SYST -M #7 RECEIVED AUG 222012 PERMIT CENTER ENGINEER: co Co 0 Q H I I III N O N 0 0 i‹) NI N) c0 0 CZ z 0 H EXPIRES: 07 -06 -12 S HARGROVE CHECKED BY: B GEZON w 0 w Q 0 z 0 F- U F- (') z 0 U 0 U- 0 W C J LAST REVISED: 07 -02 -12 DATE PLOTTED: 07 -02 -12 CAD: ISSUE DATE S HARGROVE 07 -02 -12 DRAWING NUMBER: D-1240-7225117-00 SHEET NUMBER: TM4.O1 -7 L(29 11 IF - -- '7C_j e s a` co X lf) i ♦♦ .. ♦ e l ♦ . \\ `e `♦ `e ``e s • `♦ `, .. �" e �6 `♦ `. , ♦e `. �r .♦ `. �`••,, a`.` \ .. ``1 `. n --._ `‘`, Q -. T 3 "V. D 3" VTR 3" D d N N c M x d- o e , 1/,,,J I_ V. DPR 8/225" 80/28" 0; L RECIRC. PLENUM BELOW CO -CPAs At.:6PR,2091-427.2. FOR city of Tukwila DIN' DI.._... 18'- 0 "x2' -0" RECIRC. GRILLE TYPE D A PENT 68/26" C M24 D (AP AT WALL FIELD TO DETERMINE EXACT POC TO EXISTING RA DUCT SEE SHT M -14 FOR CONT. \TA, 28/15" F.V. DPR 63/26" TURNING VANES CENTER BETWEEN GRID LINES 53 &54 OUSE #7 PLAN f. 48 12 F.V. DPR C 48x12" TR 2000. CFM (SEE DWG. M -14) SCALE Y" =1' -0" SEE SI-IT M -14 FOR CONTINUATION `s 5 • CO Cr) 0 h N- 0 CO CAD ti CO • N to co u_ O W O C � N- T) o 4) C D j 0 • .0 N- 0 CD 00 CT) 0 LL O 0 U Q g. 2 • Z J 66 S �—,— 28/80" 18 "x16" L SCREEN 6 ■ F.A.I. LOUV ' R & BIRD - GI NL. CONTR. 38x54SL(2 ") 68/26" FILL UNUSED PORTION OF LOUVER AREA. V. DPR. (TYP.) PR /E -9 PLEf1U SECTION A -A SCALE 1/4 " =1' -0" 2' -0 "x18' -0" RECIRC. GRILLE TYPE D PG 151 MALL SYST -M #7 RECEIVED AUG 222012 PERMIT CENTER ENGINEER: co Co 0 Q H I I III N O N 0 0 i‹) NI N) c0 0 CZ z 0 H EXPIRES: 07 -06 -12 S HARGROVE CHECKED BY: B GEZON w 0 w Q 0 z 0 F- U F- (') z 0 U 0 U- 0 W C J LAST REVISED: 07 -02 -12 DATE PLOTTED: 07 -02 -12 CAD: ISSUE DATE S HARGROVE 07 -02 -12 DRAWING NUMBER: D-1240-7225117-00 SHEET NUMBER: TM4.O1 -7