HomeMy WebLinkAboutPermit PG12-160 - SOUND TRANSIT SOUNDER STATIONSOUND TRANSIT
SOUNDER STATION
7301 LONGACRES WY
PG12 -160
City oirI'ukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
PLUMBING /GAS PIPING PERMIT
Parcel No.: 2423049029
Address: 7301 LONGACRES WY TUKW
Project Name: SOUND TRANSIT SOUNDER STATION
Permit Number:
Issue Date:
Permit Expires On:
PG12 -160
09/23/2013
03/22/2014
Owner:
Name: UNION PACIFIC RAILROAD CO
Address: PROPERTY TAX , 1400 DOUGLAS STOP 1640 68179
Contact Person:
Name:
Address:
Email:
Contractor:
Name:
Address:
KYM WILLIAMS
401 S JACKSON ST , SEATTLE WA 98104
KYM. WILLIAMS @SOUNDTRANSIT.ORG
UNIVERSITY MECH CONTR INC
11611 49TH PL W , MUKILTEO WA 98275 -4255
Contractor License No: UNIVMC *343N9
Phone: 206 - 398 -5156
Phone: 206 - 364 -9900
Expiration Date: 10/03/2014
DESCRIPTION OF WORK:
INSTALL PLUMBING FIXTURES TO NEW COMFORT STATION /ANCILLARY BUILDING.
Value of Plumbing /Gas Piping:
Fees Collected:
Electrical Service Provided by:
$10,000.00
$345.19
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
xam
with
The granting of this permit does not pre
construction or the performance of work.
on the back of this permit.
/ f Signature: , .
Print Name: t ( c,t ilr of 1
M,
Uniform Plumbing Code Edition:
International Fuel Gas Code Edition: 2009
2009
Date:
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
me to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions
Date: 9/?3/aW3
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -4/10
PG12 -160 Printed: 09 -23 -2013
PERMIT CONDITIONS
Permit No. PG12-160
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures
and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use
significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in
accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments.
12: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
doc: UPC -4/10
PG12-160 Printed: 09 -23 -2013
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Plumbing/Gas Permit No. -vCj (d-- (t V
T1)---‘ Project No. 4 1
Date Application Accepted:) - -( 2
Date Application Expires:
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.:
Site Address: 7301 Longacres Way Suite Number: Floor:
Tenant Name: Sound Transit
PROPERTY OWNER
Name: Kym Williams
Address: 401 S Jackson St
Name: Sound Transit
Phone: (206) 398 -5156 Fax: (206) 398 -5228
Email: Icym.williams@soundtransit.org
Address: 401 S Jackson St
City: Seattle
State: WA
Zip: 98104
CONTACT PERSON — person receiving all project
communication
Name: Kym Williams
Address: 401 S Jackson St
City: Seattle State: WA Zip: 98104
Phone: (206) 398 -5156 Fax: (206) 398 -5228
Email: Icym.williams@soundtransit.org
New Tenant: ❑ Yes
PLUMBING CONTRACTOR INFORMATION
Company Name: TBD
Address:
City:
State:
Zip:
Phone:
Fax:
Contr Reg No.:
Exp Date:
Tukwila Business License No.:
Valuation of Project (contractor's bid price): $ / U pbb
Scope of Work (please provide detailed information):
Install plumbing fixtures to new comfort station/ancillary building
Building Use (per Int'l Building Code): B
Occupancy (per Intl Building Code):
Utility Purveyor: Water
IIB
H: Applications\Forns- Applications On Line \2011 Applications\Plumbing Permit Application Revised 8 -9 -1 l.docx
Revised: August 2011
bh
Sewer
Page 1 of 2
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
4s
Shower, single head trap
1
Sinks
1
Rain water system — per
drain (inside building)
I
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
4s
Lavatory
1
Urinal
1
Water heater and/or vent
I
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
4s
Wash fountain
Water closet
1
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
4s
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1 -5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR- UTH 1 RIZE t GENT:
Signature:
Print Name: K
illiams
Mailing Address: kym.williams @soundtransit.org
H:\Applications\For s- Applications On Line \2011 Applications\Plumbing Permit Application Revised 8 -9.1 I.docx
Revised: August 2011
bh
Date:
Day Telephone: (206) 398 -5156
Seattle WA 98104
City State Zip
Page 2 of 2
Cit,of Tukwila,
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http : /hvww. ci. tukw ila. wa. us
SET RECEIPT
RECEIPT NO: R13 -00822
Initials: WER
Payment Date: 02/15/2013
User ID: 1655 Total Payment: 236,452.44
Payee: SOUND TRANIST
SET ID: 0215 SET NAME: SOUND TRANSIT
SET TRANSACTIONS:
Set Member Amount
D12 -272 223,072.45
EL12 -0777 11,167.15
M12 -117 1,867.65
PG12 -160 345.19
TOTAL: 223,072.
TRANSACTION LIST:
Type Method Description Amount
Payment Check 00107206
ACCOUNT ITEM LIST:
Description
TOTAL:
236,452.44
236,452.44
Account Code Current Pmts
BUILDING - NONRES
CASCADE WATER ALLIANCE
ELECTRICAL PERMIT - NONR
FLOOD ZONE CONTROL
MECHANICAL.- NONRES
PLAN CHECK - NONRES
PLAN CHECK - WATER METER
PLUMBING - NONRES
PW LAND ALT PERMIT FEE
PW PERMIT /INSPECTION FEE
PW PLAN REVIEW
STATE BUILDING SURCHARGE
WATER CONNECTION
WATER INSPECTION FEE
WATER INSTALLATION (DEP)
LT 'A mt1T] .TT TO TT (NTT EM, L,
000.322.100
640.237.500
000.322.101.00.0
000.322.400
000.322.102.00.0
000.345.830
000.345.830
000.322.103.00.0
000.342.400
000.342.400
000.345.830
640.237.114
401.379.002
401.342.400
401.245.100
27,561.95
84,070.00
11,167.15
50.00
1,867.65
69.04
30.00
276.15
721.00
86,895.00
17,895.00
4.50
685.00
45.00
4,965.00
A Al -311") A AC 1 CA AA
t4tio
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
F61Z -1.043
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
So0AA TrGtAci'
Type Inspection:
1 Uiv •
,��
r". 1\JAL,
Address:
% ," o 1 L
, ', Ac !PS
Date Ca led:
Special Instructions:
Date Wanted:
/
6"
a:_ro:
2Z--1 p.m.
Requester /tit
Phone No:
8429
UApproved per applicable codes. LJ Corrections required prior to approval.
COMMENTS:
(1 [re. fA 0n j A4,4-6V
Inspe, tor:._
Date:' 0
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
S
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
Type of Ins ction:
7-",44frift/ )C,:keZe
Date Called:
Addr
�r� S (d/
4
r 601-,
Special` nst ctions: j
/
Date Wanted:4P--261V,/
a
P.m.
Requester:
Phone No:
Approved per applicable codes. \Corrections required prior to approval.
COMMENTS:
r)
etv
ce.s-- ( f -,'cam,
-/a
oar .-, rj1 6 /S 4 —
Date: L/
REINSPECTION FEE REQUIRED: Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit t&2- Oo
PERMIT NO.
•CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 .(206) 431-3670
Permit Inspection. Request Line (206) 431-2451
Project: i ,, 1
50uAak ( toLEV irS dUA0/4.41.,
Typrpf Inspection: ,,, ,
Ko u &t-i-- T.,h.r F t,..i ivc ,
Address:
7 301
Date Called:
Special Instructions:
•
--I
/
Date Wanted:
- I 2- -I 2._--
/
Requester:
..,0"
Phone,6: .
LY'r !.\ -'
.
Approved per applicable codes. ¶j Corrections required prior to approval.
COMMENTS:
-I 5 () e
FR_
St.
Date:
2— -- (3
REINSPECTION FEE REQUI ED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd. Suite 100. Call to schedule reinspection.
�*3
INSPECTION RECORD
Retain a copy with permit
Lo
INSPECTION NO. PERMIT. N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Protect: \.___, E
- u t 1o. 4.5,
Typ of Inspection: P
o c6 TN ( 44
Address:
"73oi L
, res
Date Called:
Special Instructions:
Date Wanted:
i�o _ l- /3
m
a..
� ,,
Requester:
Phone rN 4 4 4 -0
1
Approved er applicable codes. tl Corrections required prior to approval. `
COMMENTS:
D-&r - _�FGA�11
(-(o
D." 7 '(.
Ilispector:.
Date:
n REINSPECTION FEE' QU I . rior to next inspection, fee must be -
paid at 6300 Southcen r Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT N0.
CITY OF.TUKWILA BUILDING DIVISION
Blvd., #100, Tukwila.. WA 98188 - (206) 431 -3670
Permit Inspection Request-Line (206) 431 -2451
Project: 0.-- •
C\(1�k I t/-Ic.)514
Type o nspection:
6r11 - ■
Plu.;,.,A),4..>\
Address:
-73o t LO- rvc�Ae)a.
Date Called:
f
Special Instructions:
• Y
Date Wanted:
1 (.0 — y- 13
ate,
p.m.
Requester:
Phone N
.-
Approved per applicable codes. Corrections required prior to- approval.
COMMENTS:
0 - [3._r�
1 `.J
I n s t ctor:
Dater 0---7
n REINSPECTION FEE REQUIRED \Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
('6R-ILno
Project:
.. ‘./A
�.�
i 7c, .�1', -
Type of Inspection:
f u Li e..v t,.• -JU i
!�
Address:
---7 1/
1s��,��
Date Called:
�
Special Instructions:
(
ate Wanted
2- -r�_ ..
'aim..
p.m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
di
Inspect_
n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
Dater
June 18, 2014
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
KymWilliams
Sound Transit
401 S Jackson Street
Seattle, WA 98104 -2826
RE: Request for Extension #2
Permit Number PG12 -160
Sound Transit Sounder Station — 7301 Longacres Wy
Dear Mr. Williams,
This letter is in response to your written request for an extension to Permit PG12 -160. The Interim
Building Official has reviewed your letter and considered your request to extend the above referenced
permits. The City of Tukwila Building Division will be extending your permit through June 10, 2014.
If you should have any questions, please contact our office at (206) 431 -3670.
File: Permit No. PG12 -160
W:\Permit Centet\Extension Letters\Permits\2012\PG12 -160 Permit Extension #2.docx
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665
SOUNDTRANSIT
June 10, 2014
Mr. Bob Benidicto, PE
Building Official
Department of Public Works
City of Tukwila
6300 Southcenter Blvd, Suite #100
Tukwila, WA 98188
Permit Extension Request for Permit #PG12 -160
Dear Mr.Benedicto,
RECEIVED
�;liti f1i' ►<WILA
JUN 10 2014
+'ERMIT CENTER
Sound Transit respectfully requests an extension of its current public works permit,
#PG12 -160 for continuing construction of Tukwila Sounder Station. The permit
extension will allow our contractor to continue and complete ongoing work efforts. The
station is anticipated to be substantially complete this October. If you have any questions
regarding this request please feel free to contact me directly via my information below.
Sincerely,
Kym illiams
As tant Permit Administrator
(206) 398 -5156
kym.williams @soundtransit.org
CC: Jon O'Hare, Sound Transit
Laurie Werle, City of Tukwila
tif 0(0 0 IH
f<'�I;If for
Central Puget Sound Regional Transit Authority • Union Station
401 S. Jackson St., Seattle, WA 98104 -2826 • Reception: (206) 398 -5000 • FAX: (206) 398 -5499
www.soundtransit.org
CHAIR
Pat McCarthy
Pierce County Executive
VICE CHAIRS
Julia Patterson
King County Councilmember
Aaron Reardon
Snohomish County Executive
BOARD MEMBERS
Claudia Balducci
Bellevue Councilmember
Fred Butler
Issaquah Council President
Richard Conlin
Seattle Councilmember
Dow Constantine
King County Executive
Dave Earling
Edmonds Mayor
Dave Enslow
Sumner Mayor
John Marchione
Redmond Mayor
Joe McDermott
King County Councilmember
Mike McGinn
Seattle Mayor
Mary Moss
Lakewood Councilmember
Lynn Peterson
Washington State Secretary of
Transportation
Larry Phillips
King County Councilmember
Paul Roberts
Everett Councilmember
Marilyn Strickland
Tacoma Mayor
Peter von, Reichbauer
King County Councilmember
CHIEF EXECUTIVE OFFICER
Joni Earl
5/1/2014
City of Tukwila
Department of Community Development
KYM WILLIAMS
401 S JACKSON ST SEATTLE, WA
MINNELPOLIS, MN 98104
RE: Permit No. PG12 -160
SOUND TRANSIT SOUNDER STATION
7301 LONGACRES WY
Dear Permit Holder:
Jim Haggerton, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of
such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun
for a period of 180 days. Your permit will expire on 6/10/2014.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 438 -9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and /or receive an extension prior to 6/10/2014, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
r } Aikr5la
ennif r Marshall
mitlTechnician
File No: PG 12 -160
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665
September 9, 2013
Kym Williams
Sound Transit
401 S Jackson St
Seattle, WA 98104
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
RE: Request for Reactivation
Permit Numbers M12 -117, PG12 -160 & EL12 -0777
Sound Transit Sounder Station — 7301 Longacres Wy
Dear Mr. Williams,
This letter is in response to your written request for reactivation of Permit Numbers M12 -117, PG12 -160
and EL12 -0777. The Building Official has reviewed your letter and considered your request to reactivate
the above referenced permits. It has been determined that the City of Tukwila Building Division will be
reactivating your permit applications an additional 90 days from today's date, through December 9, 2013.
Once issued, a new 180 day period will start before expiration.
If you should have any questions, please contact our office at (206) 431 -3670.
Sincerely,
Bill Rambo
Permit Technician
File: Permit No. M12 -117, PG12 -160 & EL12 -0777
W:IPermit CenterlExtension Letters1Permits120121EL12 -0777 Permit Reactivation.docx
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665
Bill Rambo
From:
Sent:
To:
Cc:
Subject:
Importance:
Hi Bob —
Williams, Kym <kym.williams @soundtransit.org>
Friday, September 06, 2013 4:51 PM
Bob Benedicto
O'Hare, Jon; Bill Rambo
Permit Renewals Tukwila Commuter Rail Station
High
Thank you so much for returning my phone message. Per your request here is my email to you asking formally for
renewal /extension of trades permits M12 -117, PG12 -160, and EL12 -0777. Additionally, it may also be that the
construction permit D12 -272 is expired as well as most of these permits were sent renewals simultaneously. If not too
much of a trouble I request that this permit too be renewed consistent with the rest. Thank you again for your time. If
any questions, do not hesitate to contact me. Have a great weekend.
Kym Williams
Assistant Permit Administrator
Sound Transit
Dept of Engineering and Construction Management
P: 206 398 -5156
C: 206 473 -0910
Kym.williams @soundtransit.org
e.Ck,-L.e
&O v ra
addilkovixt, dae,
\it
f0C 201'3
1
RECEIVED
CITY OF TUKWILA
SEP 0 6 2013
PERMIT CENTER
City �f Tukwila
•
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
____.)
04 -02 -2013
KYM WILLIAMS
401 S JACKSON ST
SEATTLE WA 98104
RE: Permit Application No. PG12 -160
SOUND TRANSIT SOUNDER STATION
7301 LONGACRES WY TUKW
Dear Permit Applicant:
In reviewing our current application files, it appears that your permit applied for on 08/22/2012, has not been
issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code,
Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days
from the date of application shall expire and become null and void. Your permit application will expire on
05/13/2013.
If you still plan to pursue your project, a written request for extension of your application must be submitted to the
Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building
Official and state your reason(s) for the need to extend your permit application. If it is determined that an
extension is granted, your application will be extended for an addtional 90 days from the expiration date and you
will be notified by mail.
In the event that we do not receive your written request for extension or request was denied, your permit
application will expire, become null and void and your project will require a new permit application, plans and
specifications, and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File: Pennit File No. PGI2 -160
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206- 431 -3665
1T
January 29, 2013
City Tukwila
•
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
Jon O'Hare
Sound Transit
401 S Jackson Street
Seattle, WA 98104 -2826
RE: Request for Extensions
Permit Numbers D12 -272, EL12 -0777, M12 -117, and PG12 -160
Sound Transit Sounder Station — 7301 Longacres Wy
Dear Mr. O'Hare,
This letter is in response to your written request for an extension to Permit Numbers D12 -272, EL12-
0777, M12 -117, and PG12 -160. The Building Official has reviewed your letter and considered your
request to extend the above referenced permits. The City of Tukwila Building Division will be extending
your permits an additional 180 days from the date of expiration, through May 13, 2013.
If you should have any questions, please contact our office at (206) 431 -3670.
Sincerely,
fivi-A.84\an
shall
ician
File: Permit No. D12 -272, EL12 -0777, M12 -117, & PG12 -160
W :IPermit CenterlExtension LetterslPermits120121D12 -272 Permit Extension.docx
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665
•
SOUNDTRANSIT
January 18`h, 2013
Jack Pace
Director of Community Development
Department of Community Development
City of Tukwila
6300 Southcenter Boulevard, Suite # 100
Tukwila, WA 98188
•
Permit Extension Request for Department of Community Development Permits M12-
117, EL 12 -0777, D12-272, and Pt- TDI-*1^
erAppL1 ED
Dear Mr. Pace, S/uo/ c to
Pursuant to IBC, IMC, UPC, and NEC, Sound Transit respectfully requests 90 day
extensions for the following DCD permits:
N C \)-` \ (.I? 0 0.t'PP -DYED
1. Building Permit D12-272 (Sounder R E ,
2. Mechanical Permit M12 -1171 RCO D (L- fiJRN pwcv;
3. Electrical Permit EL12- 0777ArPoz'
4. Plumbing/Gas Permit s' tp 0 4.hP!oJE1"
All above permits are scheduled to expire on 2/12/2013. Design changes and funding
have delayed us in getting these permits issued. The permit sets have been resubmitted
for review and we are working diligently on getting these permits issued and work
underway. These permits are critical to the essential forward progress of building the new
sounder station for our customers.
If you have any questions regarding this request, please contact me immediately at the
number listed below.
Sincerely
O'Hare
Permits Administrator
(206) 903-7368
r!
l Yk.0 b 2bl vu/W'
to 751b U P4WED
AMOUNT, o:
QTY OF TU 1N1Lp.
1JAN 2.2.2013,
PERMIT CENTER
od< 40 644d la
-(41-63
72z/zog
Qx"-o c�
Central Puget Sound Regional Transit Authority • Union Station
401 S. Jackson St., Seattle WA 98104 -2826 • 206 - 398 -5000 • 1- 800 - 201 -4900 • www.soundtransit.org
=CHAIR
Pat McCarthy
Pier'c'e County Executive
VICE CHAIRS
:Julia Patterson.
King County- Coun'cilnieniber
Aaron Reardon
.Snohoniish County Executive'
BOARD MEMBERS
Claudia Balducci
Bellevue Cotrncilmen:ber
'Fred Butler
Issaquah Deputy,Counc:1 President
Richard Conlin
Seattle Councilmember,
Dow Constantine
Kiirg 'County Executive
Dave Earling
Edmonds Mayor
Dave Enslow
Sumner Mayor
Paula J. Hammond P.E.
( ' 'Washington State Secretary of
.Transportation".:.
John Marchione ;
.Redmond May°
Joe McDermott'
King County Councilmeryber
Mary Moss a�-
1 akewoodCouncilmember.
Larry Phillips
:• King County Corincilmeniber-
Paul Roberts
verett Councilmember
Marilyn Strickland
.Tacoma Mayor;
Peteryon Reichbauer
g `County. Councrinreniber
.T, k
CHIEF. EXECUTIVE OFFICER'
om Earl"'
01 -02 -2013
KYM WILLIAMS
401 S JACKSON ST
SEATTLE WA 98104
ukwila
•
Jim .Haggerton,-Mayor
.epartment:of Cortimunity Development JackPace; Director
RE: Permit Application No. PG12 -160
SOUND TRANSIT SOUNDER STATION
7301 LONGACRES WY TUKW
Dear Permit Applicant:
In reviewing our current application files, it appears that your permit applied for on 08/22/2012, has not been
issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code,
Uniform Plumbing Code and /or National Electrical Code every permit application not issued within 180 days
from the date of application shall expire and become null and void. Your permit application will expire on
02/18/2013.
If you still plan to pursue your project, a written request for extension of your application must be submitted to the
Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building
Official and state your reason(s) for the need to extend your permit application. If it is determined that an
extension is granted, your application will be extended for an addtional 90 days from the expiration date and you
will be notified by mail.
In the event that we do not receive your written request for extension or request was denied, your permit
application will expire, become null and void and your project will require a new permit application, plans and
specifications, and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File: Permit File No. PG12 -160
6300 Southcenter Boulevard; Suite: #100 Tukwila, Washington 98188 • Phone 206-431 =3670: Fax 2,06 -431 -3665
lEflitiff CO COP?
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG12 -160 DATE: 08 -22 -12
PROJECT NAME: SOUND TRANSIT SOUNDER STATION
SITE ADDRESS: 7301 LONGACRES WY
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
Bui ina- Division y 1 0 1.17—
Public Works
Fire Prevention
n
Planning Division
Structural n Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
DUE DATE: 08 -23 -12
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route gl. Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 09-20-12
Not Approved (attach comments)
DATE:
Permit Center; Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Punter Friendly Page
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent Company
UNIVERSITY MECH CONTR INC
2063649900
11611 49Th Pl W
Mukilteo
WA
982754255
Snohomish
Corporation
UBI No. 578025176
Status Active
License No. UNIVMC *343N9
License Type Construction Contractor
Effective Date 8/29/1966
Expiration Date 10/3/2014
Suspend Date
Specialty 1 General
Specialty 2 Unused
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty 2
Effective
Date
Expiration
Date
Status
UNIVEMC009C4
UNIVERSITY MECH
CONTR INC
Electrical
Contractor
Hvac /Rfrg
Lighting
Maintenance
2/24/2000
7/30/2014
Active
GRANSML982R3
GRANSTON
MECHANICAL LLC
Construction
Contractor
General
Unused
12/23/2002
1/8/2009
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
BUSH, GERALD D
President
03/13/2002
Bond Amount
GRANSTON, EDWARD B
Secretary
03/13/2002
08965196
PETTERSON, DEAN M
Treasurer
03/13/2002
SMITH, DOUG
Vice President
03/18/2002
TRAVELERS CAS &
SURETY CO
KOMMERS, EDWARD D
Vice President
03/13/2002
09/13/2004
BALDWIN, TERRY L
Vice President
03/13/2002
09/10/2003
GRANSTON, FRANK
Treasurer
03/18/2002
12/23/2002
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
7
FIDELITY Et DEPOSIT
CO OF MD
08965196
07/31/2009
Until Cancelled
$12,000.0006/04
/2009
6
TRAVELERS CAS &
SURETY CO
103335164
07/22/2001
Until Cancelled
07/31/2009
$12,000.0010/03
/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
31
Phoenix
Insurance
Company, The
DTC0526D8270PHX11
06/01/2011
06/01 /2014
$1,000,000.0005
/03/2013
30
THE PHOENIX
INS CO
C0526D8270PHX10
10/01/2010
10/01/2011
$1,000,000.0009
/22/2010
29
PHOENIX INS CO
C0526D8270PHX09
10/01/2009
10/01/2010
$1,000,000.0009
/22/2009
28
TRAVELERS
PROPERTY CAS
INS CO
DTE0526D8270TIL07
10/01/2007
10/01/2009
$1,000,000.0009
/19/2008
27
TRAVELERS
PROPERTY CAS
INS CO
DTEC0526D8270TIK07
10/01/2007
10/01/2008
$250,000.0009/21
/2007
http s : / /fortress . wa. gov /lni /bbip /Print. aspx
09/23/2013
•
Gen Notes.dwg 6/15/2012 1:1
110801 _TK —M0.01 LEGEND
i
1'E PERMIT
RC-OUIRED •
1
Eleabled
0 Rafting
D Gas Ploky
City of TukvvIta
$UILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittatr
and may include additional plan review fees:- ,
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 10 2012
City of u iia
BUILDIN i ISION
FILL' CO 'v
Permit No., P( \2_ 1,1D
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledged:
By '
Date :. VolV203
City Of Tukwila
BUILDING DIVISION
GENERAL NOTES
1. THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW THE
EXACT DETAILS AND LOCATIONS, NOR ALL OFFSETS IN
DUCTWORK AND PIPING. CONTRACTOR SHALL PROVIDE
ADDITIONAL FITTINGS, OFFSETS AND EXTENSIONS IN PIPING,
DUCTWORK AND RELATED MECHANICAL INSULATION AS
REQUIRED TO MEET THE INTENT OF THE DOCUMENTS.
CONTRACTOR SHALL INCLUDE IN HIS BID PROVISIONS TO
RELOCATE OR SHIFT PIPING AND DUCTWORK WHERE
CONFLICTS EXIST WITH STRUCTURE, ARCHITECTURE OR
ELECTRICAL.
CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OWN
COORDINATION BETWEEN ALL OTHER TRADES. DEVELOPMENT
OF SHOP DRAWINGS SHALL BE A COLLABORATIVE EFFORT
BETWEEN THE GENERAL CONTRACTOR, MECHANICAL
CONTRACTOR AND ALL OTHER SUBCONTRACTORS WORKING
ON THE PROJECT. SHIFTING OF PIPING, DUCTWORK AND
OTHER MECHANICAL ITEMS SHALL BE THE RESPONSIBILITY OF
THE CONTRACTOR TEAM TO MAINTAIN THE INTENT OF THE
DOCUMENTS.
MAINTAIN MAINTENANCE & SERVICE ACCESS TO ALL
MECHANICAL EQUIPMENT. GENERALLY RUN PIPING &
DUCTWORK AS HIGH AS POSSIBLE, AVOID MAJOR WALKWAYS
& ACCESS ROUTES.
4. SHEET METAL: ALL PRODUCTS SHALL COMPLY W/ SMACNA
DUCT CONSTRUCTION STANDARDS, SECOND EDITION.
5. SEAL ALL DUCT WORK AS REQUIRED BY WASHINGTON STATE
ENERGY CODE.
6. PROVIDE LEAK TESTING FOR HIGH AND /OR LOW PRESSURE
DUCTWORK AS REQUIRED BY WASHINGTON STATE ENERGY
CODE.
7. RATING OF ACCESS DOORS AND /OR ACCESS PANELS
THROUGH FIRE -RATED WALLS, SHAFTS, CEILINGS, ETC., MUST
EQUAL THE MATERIAL PENETRATED.
8. ALL EQUIPMENT SHALL BE LABELED PER PLAN
DESIGNATIONS.
9. ALL RECTANGULAR & ROUND DUCTWORK SIZES SHOWN ARE
SHEET METAL. PROVIDE TURNING VANES IN ALL
RECTANGULAR 90- DEGREE ELBOWS, &• WHERE SHOWN ON
ROUND DUCT.
10. PROVIDE NEC CODE MINIMUM WORKING CLEARANCE IN FRONT
OF & OVER ANY ELECTRICAL PANEL. OFFSET PIPING &
DUCTWORK AS REQUIRED.
11. DUCTWORK SHALL MEET THE INSULATION REQUIREMENTS OF
THE WASHINGTON STATE ENERGY CODE. ALL SHEET METAL
DUCTWORK SHALL BE INSULATED IN ACCORDANCE WITH THE
WASHINGTON STATE ENERGY CODE.
12. ALL PIPING SHALL BE INSULATED IN ACCORDANCE W/ THE
WASHINGTON STATE ENERGY CODE, INCLUDING REFRIGERANT
PIPING.
13. DIFFUSERS & GRILLES SHALL BE COORDINATED W/
PLACEMENT OF LIGHT FIXTURES.
14. MECHANICAL CONTRACTOR SHALL VERIFY HEIGHT, DEPTH, &
LOCATION OF LIGHT FIXTURES TO AVOID ALL CONFLICTS WITH
DUCTS, EQUIPMENT & MOUNTING BRACKETS. ALLOW A
MINIMUM OF 3" CLEARANCE ABOVE LIGHTING FIXTURES FOR
INSTALLATION OF WIRING CONNECTIONS.
15. COORDINATE LOCATIONS OF ALL EQUIPMENT AND
APPURTENANCES W/ OTHER TRADES.
16. CONTRACTOR. SHALL PROVIDE COMPLETE OPERATING
SYSTEMS. .
17. WHERE FLEXIBLE DUCTWORK IS SHOWN TO CONNECT TO
CEILING DIFFUSERS, PROVIDE 6' MAXIMUM OF FLEXIBLE DUCT.
USE INSULATED DIFFUSER BOX AT DIFFUSER. SEE DETAIL 2,
SHEET' M1.01.
18. PROVIDE VOLUME DAMPERS AT ALL BRANCHES FOR
BALANCING.
19. PROVIDE FLEXIBLE CONNECTORS AT SUPPLY AIR & RETURN
AIR CONNECTIONS TO EQUIPMENT
20. MECHANICAL SYSTEMS SHALL COMPLY W/ CHAPTER ° 14 OF
THE WASHINGTON STATE ENERGY CODE.
21. CONTROLS SHALL ALLOW FOR AIR SYSTEM TEMPERATURE
RESET, MINIMUM 5- DEGREE DEAD BAND, OPTIMUM START,
AND NIGHT SETBACK
22. PROVIDE O &M MANUALS, OWNER TRAINING, AND RECORD
DRAWINGS PER SPEC SECTIONS 20 08 00. BALANCE AIR
AND WATER SYSTEMS PER SECTION 23 05 93. COMMISSION
SYSTEMS PER SECTIONS 20 08 00.
RECEIVED
AUG 2 3 2012
TUKVVILA
p NLID WORKS
RECEIVED
AUG 2 2 2012
PERMIT CENTER
P612 -Imo
No.
Date
By
Chk.
App.
Revisions
Designed By
scs
Drawn By.
TMP
Checked By.
DMM
Approved By.
WYL
Scale:
•IngConsulting Engineers
1601 Flfth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622 -5822 Fax (206) 622 -8130
31308.
06/1
Submitted:
Date:
T R E S W E S T
ENGINEERS ,INC.
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE (253) 472 3300
FAX (253) 472 3463
Approved:
SOUNDTRANSIT
Date:
•
90% PER
\1T SUBvITTAL_
NO SCALE SOU \ 3 TR A \SIT TJ <W L_A STAT O\
Filename:
TK -M0.0 I .dwg
Contract No.:
RTA /CP 0 101 -05
Date:
06/1 5/1 2
T�
<W ILA, 'WASH \ GTO\
Drawing No.:
MECHAN I CAL LEGEND AND GENERAL NOTES
MECHAN 1 CAL LEGEND
SYMBOL
DESCRIPTION
COLD WATER (CW)
HOT WATER (HW)
WASTE OR SANITARY SEWER (W OR SS)
--
- - - - --
VENT (V)
FIRE SPRINKLER PIPING
F
PIPE DOWN
I,
c I
PIPE UP
+�
BRANCH - SIDE CONNECTION
i .
CAP END OF PIPE
FLOW DIRECTION
FLUSH CLEANOUT (FCO) OR SURFACE
CLEANOUT (SCO) AS INDICATED
o
NON- FREEZE WALL BOX HYDRANT (NFBH)
/
GATE VALVE (GV)
CHECK VALVE (CV)
TEMPERATURE /PRESSURE RELIEF VALVE (T &PV)
STRAINER
—CIE
UNION
--
BALL VALVE (BV)
DRAIN VALVE WITH HOSE CONNECTION
OR HOSE BIBB
4
AUTOMATIC OR MANUAL AIR VENT (AAV, MAV)
0
PRESSURE GAUGE
THERMOMETER
REDUCED PRESSURE BACKFLOW PREVENTER
RPBP
FLOOR DRAIN (FD)
o
FLOOR & FUNNEL DRAIN (F &FD)
•
SUPPLY AIR -DUCT UP
�E
EXHAUST /RETURN AIR - DUCT UP
=
SUPPLY AIR - DUCT DOWN
ilibiEr.
EXHAUST /RETURN AIR - DUCT DOWN
Mai= `
12/1_1_,...2 RR
300 CFM
AIR TERMINAL SIZE, TYPE &
CUBIC FEET PER MINUTE (CFM)
CEILING AIR TERMINAL - SQUARE
N
BACKDRAFT DAMPER (BDD)
-II
FLEXIBLE CONNECTION (DUCT)
OT
ROOM TEMPERATURE SENSOR /THERMOSTAT
--A.
COMBINATION FIRE /SMOKE DAMPER (CFSD)
G.C.
GENERAL CONTRACTOR
M.C.
MECHANICAL CONTRACTOR
E.C.
ELECTRICAL CONTRACTOR
WCO
WALL CLEAN OUT
SCO
SURFACE CLEAN OUT
FCO
FLOOR CLEAN OUT
T &P
TEMPERATURE AND PRESSURE RELIEF VALVE
BFV
BUTTERFLY VALVE
RD
ROOF DRAIN
ORD
OVERFLOW ROOF DRAIN ,
POC
POINT OF CONNECTION
90% PER
\1T SUBvITTAL_
NO SCALE SOU \ 3 TR A \SIT TJ <W L_A STAT O\
Filename:
TK -M0.0 I .dwg
Contract No.:
RTA /CP 0 101 -05
Date:
06/1 5/1 2
T�
<W ILA, 'WASH \ GTO\
Drawing No.:
MECHAN I CAL LEGEND AND GENERAL NOTES
A
DUCTLESS SPLIT SYSTEM OUTDOOR UNIT SCHEDULE
, UNIT
NO
SERVICE
MFR
MFR /MODEL
COOLING
HEATING
SEER
POWER CONNECTION
OPERATING
WEIGHT
(LBS) -
NOTES
TOTAL
MBH
OA
('F)
TOTAL
MBH
OA
(°F)
MCA
MOP
VOLT /PH
CU -1
ELECTRICAL ROOM
MITSUBISHI
PUZ— HA3ONHA2
30
95
19
17
16.1
28
30
208/1
265 -
00
NOTES:
0 DO NOT EXCEED MAXIMUM TUBING LENGTH. 02 M.C. TO PROVIDE POWER WIRING TO INDOOR UNIT PER MANUFACTURER'S INSTALLATION INSTRUCTIONS.
DUCTLESS SPLIT SYSTEM INDOOR UNIT SCHEDULE
UNIT
NO
SERVICE
MFR
MFR / MODEL
CFM
TOTAL
COOLING
MBH
EAT
POWER CONNECTION (2)
OPERATING
WEIGHT
(LBS)
FILTER
SEER
NOTES
DB (F)
WB (°F)
FLA
MCA
VOLT /PH
AC -1
ELECTRICAL ROOM
MITSUBISHI
PCA— A3OKA4
565
30
80
67
0.54
1
208/1
71
WASHABLE
16.1
0000
NOTES:
0 410a REFRIGERANT O POWER CONNECTION FROM OUTDOOR UNIT O PROVIDE W/ HARD —WIRED WALL — MOUNTED REMOTE CONTROLLER
O PROVIDE W/ INTEGRAL CONDENSATE PUMP
FAN SCHEDULE
UNIT
NO
MFR
MODEL
AREA SERVED
TYPE
PERFORMANCE
POWER CONNECTION
BACK
DRAFT
DAMPER
SPEED
CONTROLLER
WEIGHT
(POUNDS)
NOTES
CFM
TSP (IN)
RPM
SON
HP /W
VOLT /PH
EF -1
COOK
GN 162
RESTROOM
IN LINE
130
0.25
1074
2.0
86 W
120 /1
YES
YES
18
00
EF -2
COOK
GN 162
JANITOR
CEILING
130
0.25
1074
2.0
86 W
120/1
YES
YES
18
00
NOTES:
0 SWITCH W/ ROOM LIGHTS 02 PROVIDE W/ FACTORY —WIRED SPEED SWITCH & WHITE ALUMINUM GRILLE
GRILLE, REGISTER, DIFFUSER AND LOUVER SCHEDULE
SYMBOL
AIR TERMINAL
EGH
EXHAUST GRILLE TITUS MODEL 50 —F FOR INSTALLATION IN HARD CEILING. PAINT DUCT MATTE BLACK BEHIND GRILLE. FINISH SHALL BE #26 WHITE. SEE PLANS FOR SIZES.
WTG
WALL TRANSFER GRILLE: TITUS MODEL 350 —RL STEEL GRILLE WITH HORIZONTAL BLADES SPACED 3/4" AND 35° DEFLECTION. SEE PLANS FOR SIZES. PAINT DUCT MATTE
BLACK BEHIND GRILLE. FINISH SHALL BE #26 WHITE. TURN BLADES UP.
SWSG
SIDEWALL SUPPLY GRILLE TITUS MODEL 300 -FL DOUBLE DEFLECTION REGISTER WITH 3/4" BLADE SPACING. FINISH SHALL BE #26 WHITE.
WPL
LOUVER; SEE ARCHITECTURAL PLANS AND SPECIFICATIONS
ELECTRIC POINT-OF-USE WATER HEATER SCHEDULE
UNIT
NO
AREA SERVED
,
LOCATION .
MFR
MODEL
ELECTRICAL
TEMP.
RISE °F.
GPH 0
60° RISE
CAPACITY
(GALLONS)
OPERATING
WEIGHT LBS
NOTES
VOLT /PH
KW
WH -1
ANCILLARY BUILDING
ROOM 104
IN— SINK — ERATOR
W -154
120/1
1.5
80'
10.4
4
15
INCLUDE 3' CORD WITH GROUNDED PLUG
PLUMBING FIXTURE SCHEDULE
FIXTURE
NO
FIXTURE
DESCRIPTION /MFR /MODEL NUMBERS
LOCAL PIPING CONNECTION
NOTES
W
V
CW
HW
P-1A
WATER CLOSET
DURA— WARE, WALL HUNG, COMPACT SIPHON JET: ACORN ENGINEERING 2105— T- 1 -FVB0 —ADA,
DUAL FLUSH
VALVE: SLOAN "SOLIS" 8111 - 1.6/1.1 -8N' SOLAR POWERED DUAL FLUSH.
CARRIER: ZURN, 1203 —N4 —XH OR 1204— N4 —XH, 500 LB
MISC: MOUNT FLUSH CONTROLS 44" AFF; MOUNT W/ SEAT AT 17" TO 19" AFF
4"
2"
1"
—
HANDICAPPED
DUAL FLUSH
P -2A
URINAL
DURA -WARE, WALL HUNG, WASHDOWN: ACORN ENGINEERING 2158— T- 1 -FVB0 -ADA, 0.5 GALLON
FLUSH
VALVE: SLOAN "SOLIS" 8186 -0.5 SOLAR POWERED SENSOR ACTIVATED
CARRIER: PROVIDED FOR WALLS UP TO 8" THICK.
MISC: MOUNT FLUSH CONTROLS 44" AFF; MOUNT W/ RIM NO MORE THAN 17" AFF
2"
1 -1/2"
3/4"
—
HANDICAPPED
P— 3A
LAVATORY
°.
DURA -WARE, WALL HUNG, 18 "x22 ": ACORN ENGINEERING 1953LC— ADA- 1— DMS- 9- H1— GT —TPT,
TAILPIECE /TRAP INCLUDED
FAUCET: SLOAN "SOLIS" EAF -275 —ISM, 0.5 GPM SOLAR POWERED WITH INTEGRAL SPOUT
TEMPERATURE MIXER. ETF -312A 4 "CC TRIM PLATE
SUPPLIES: BRASSCRAFT NO SCR1912AC, OR EQUAL BY McGUIRE OR EASTMAN
HANGER: CONCEALED ARM CARRIER ZURN 1231
MISC: PROVIDE POWERS E480 POINT OF USE MIXING VALVE, OR APP'D EQUAL ON HOT WATER
PIPING. PROVIDE HOT /COLD WATER SUPPLY AND WASTE PROTECTION — TRAP WRAP BY BROCAR
PRODUCTS, INC. OR HANDI —LAV —GUARD BY TRUEBRO, INC. MOUNT LAV W/ RIM AT 34" AFF SO
THAT CLEARANCE HEIGHT IS AT LEAST 29"
2"
1 -1 /2"
1 /2"
1/2"
HANDICAPPED
P -5
SERVICE, SINK
FLOOR MOUNT, 36 "x24 ", MOLDED STONE, STAINLESS STEEL DOME STRAINER: FIAT NO MSB -3624
FAUCET: ADJUSTABLE INLETS, VACUUM BREAKER SPOUT, PAIL HOOK WITH WALL SUPPORT,
INTEGRAL` STOPS, 3/4" HOSE THREAD OUTLET: CHICAGO FAUCET NO 897 —CP
TRAPS & TAILPIECES: PROVIDED WITH UNDERGROUND PIPING
SUPPLIES: INTEGRAL TO FAUCET
MISCELLANEOUS: PROVIDE FIAT 832 —AA 30" LONG 3/4" 'HOSE AND HOSE BRACKET, AND FIAT
889 —CC STAINLESS STEEL MOP HANGER. SEAL SEAM BETWEEN SERVICE SINK AND WALL WITH
FIAT 832 -AA SILICONE SEALANT. PROVIDE STAINLESS STEEL WALL GUARD TO EXTEND UP WALL 2..
SIDES TO APPROX. 42" AFF
1500
2"
3/4"
3/4"
FLOOR MOUNTED
P -6
ELECTRONIC .
TRAP PRIMER
ELECTRONIC TRAP PRIMING MANIFOLD, PRECISION PLUMBING PRODUCTS MP- 500 -115V. PROVIDE
WITH DISTRIBUTION UNIT & RECESSED MOUNTING BOX W/ STAINLESS STEEL ACCESS DOOR
_
1 /2"
_
ELECTRIC HEATER SCHEDULE
UNIT NO
MFR
MODEL
LOCATION
WATTS
SIZE
VOLT /PM
NOTES
EH -1
MARKEL
E3055TDWB
_ RESTROOM
1500
10 "x12 "x3"
120/1
1 2
EH -2
MARKEL
E3055TDWB
JANITOR
1500
10 "x12 "x3"
120/1
1 2
EH -3
MARKEL
E3055TDWB
HALL
1500
10"x12" 3"
120/1
00
EH -4
MARKEL
E3055TDWB
, STORE ROOM
1500
10 "x1 2 "x3"
120/1
00
NOTES:
0 WALL MOUNTED; PROVIDE W/ MANUFACTURER'S MOUNTING FRAME
O INTEGRAL THERMOSTAT W/ "OFF" POSITION, MOUNTED ON UNIT
ELECTRIC CABINET HEATER SCHEDULE
UNIT
NO
MFR
MODEL
AREA SERVED
CFM
MOTOR
COIL kW
POWER CONNECTION
DISCONNECT
NOTES
VOLT /PH
MCA
MOP
CH -1
TRANE
FFCB020
GUARD
250
1/15
3.0
208/3
12.5
15
BY E.C.
0000
NOTES:
0 BOTTOM RETURN O OUTSIDE AIR DAMPER, AUTO TWO POSITION, BACK OUTSIDE AIR OPENING
O FRONT DUCT COLLAR O 2 -STAGE HEAT
EXPANS
1 ON TANK SCHEDULE
UNIT NO
MFR
MODEL
SERVICE
TYPE
TANK
VOLUME
MAX SIZE INCHES
NOTES
DIAMETER
HEIGHT
ET -1
ARMSTRONG
ST -5 —C
WH -1
BLADDER
2.1
10
10 -3/8
002
NOTES: 0 NSF RATED FOR POTABLE WATER O ASME RATED
MIXING VALVE SCHEDULE
UNIT NO
MFR
MODEL
SERVICE
WATER CONNECTIONS
NOTES
CW INLET
HW INLET
OUTLET
MV -1
LEONARD
370
120° HW
3/4"
3/4"
3/4"
WALL MOUNTED
CERTIFIED LEAD —FREE
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 10 2012
City of Tukwila
BUILDING DIVISION
flf9144. I b�
90% P
ECEIVED
AUG 22 2012
PERMIT CENTER
-RV T SUBV TTAL
Designed By
scs
No.
Date
By
Chk.
App.
Revisions
Drawn By
TMP
Checked By:
DMM
Approved By
WYL
EEO Consulting. Engineers
1601 Fifth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622 -5822 Fax (206) 622 -8130
T R E S W E S T
ENGINEERS ,INC.
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409-7315
TELEPHONE (253) 472 3300
FAX (253) 472 3463
SOUNDTRANSIT
Scale:
NO SCALE
Filename:
TK— M0.02.dwg
Contract -No.:
RTA /CP 0101 -05
Submitted:
Date:
Approved:
Date:
Date:
06/15/12
SOUND TRA \S T
TL, <W LA,
T KWILA STATFON
WAS
I\ GTO\
MECHAN 1 CAL SCHEDULES •
Drawing No.:
TK -MO.02
Sheet No.: Rev.:
287
J Z
3/4" RELIEF < a
VALVE SET 0 65#
-\‘
o
rz
MAV 4
NOTES:
1. ALL MATERIALS IN CONTACT
WITH WATER TO BE COPPER,
BRASS, BRONZE, EPDM, OR
STAINLESS STEEL.
SERVICE SINK
t0
z
-J
S
m
GLOBE
VALVE
144
w
in
00
1
m
aO
LO
.-3" WATER HAMMER
ARRESTOR
1- 2" HEADER
BLIND FLANGE
1 r
PRESSURE REDUCING VALVE;
33 GPM 0 80 PSI INLET &
60 PSI OUTLET
LUG -TYPE
BUTTERFLY VALVE,=
1 I Fr
GALVANIZED STEEL
SLEEVE 1" ABOVE
FF WITH LINK SEAL
2' -0"
L__
-f RPBP TO SITE BOX.
. , WALL HYDRANTS
y-AIR GAP FITTING -
PIPE DISCHARGE
FULL SIZE TO DRAIN
rFINISHED FLOOR
SUPPORT PIPES
5'
FROM BLDG
� - FINAL CONNECTION
BY M.C.
DOMEST 1 C WATER HEADER
DUCT
TAPE
SCALE: NONE
CUT 1 -1/2" RIGID
INSULATION TO FIT.
ATTACH WITH DUCT
TAPE
CONCRETE
BY G.C.
FLOOR
DRAIN
BODY
DURING CONCRETE POUR (STEP #1)
INSTALL STRAINER,
STRAINER HEAD, &
FLASHING COLLAR
(SET FINAL ELEV)
2" BUILDING SERVICE
REMOVE AND STORE
STRAINER, STRAINER
HEAD AND FLASHING
COLLAR
PIPE SIZE AS
NOTED ON PLANS
CW SUPPLY"
T
ACCESS ON WALL
COORDINATE
LOCATION W/ G.C.
STRAINER
HEAD
STRAINER
FINISHED L
GROUT
BY M.C.
�-- BALL
VALVE
—H TRAP PRIMER
I VALVE
DISTRIBUTION
UNIT
FLOOR
DRAIN
BODY
CONCRETE
BY G.C.
PIPE SIZE AS
NOTED ON PLANS
FLASHING
COLLAR
AFTER CONCRETE HARDENS (STEP #2)
NOTE: COMPLETE INSTALLATION OF FLOOR DRAIN AND
SETTING OF FINAL ELEVATION WILL NOT BE ALLOWED
DURING INITIAL CONCRETE POUR
FLOOR DRAIN I NSTALLAT 1 ON
SCALE: NONE
TO FLOOR
DRAINS
HW TO FIXTURES - SIZE
AS SHOWN ON PLAN
4 -120'F
IN -LINE FLOW
CONTROL
NOTE;
WATER HEATERS AND
EXPANSION TANKS SHALL
HAVE SEISMIC SUPPORTS
ATTACHED TO STRUCTURE
DESIGNED BY OTHERS
(TYPICAL) 0
MV -1
THERMOMETER
(30' -180')
ASME RATED COMBINATION
TEMPERATURE &
PRESSURE RELIEF VALVE
INSTANT -FLOW WATER
HEATER WH -1
CORD AND
GROUNDED PLUG
POWER GFCI
RECEPTACLE
FINISHED
FLOOR -\
1 Its
cw — SIZE AS
SHOWN ON PLAN
EXPANSION
TANK ET -1
PIPE FULL SIZE
TO MOP SINK
L__,
SERVICE SINK I
I N STAN T- FLOW WATER HEATER
1 NSTALLAT 1 ON
SCALE: NONE
ADJUSTABLE
WALL CLAMP
\\
\`
INTERIOR FACE \\
OF WALL \ \'
\\
\\'
NFBH - NON- FREEZE
WALL BOX HYDRANT
KEY - OPERATED
VALVE
VACUUM BREAKER
HOSE CONNECTION
LOCKING
COVER
KEY
EXTERIOR
FACE OF WALL
NON- FREEZE WALL BOX
HYDRANT (NFBH)
SCALE: NONE
WEATHERPROOF
LOUVER PER PLANS
DIMENSIONS
PIPE SIZE
(OUTSIDE
DIAMETER)
BASE
DIAMETER
UNIT
HEIGHT
1 /4" to 3"
7 -3/4"
4"
4" to 6"
10 -3/4"
5"
15' -0" MIN
FROM ANY FRESH
AIR INTAKE
DEK -TITE (OR APP'D EQUAL
PIPING FLASHING (SIZE AS
SHOWN BELOW)
PIPE DIAMETER
1 12"
MIN
UNIT
HEIGHT
BASE DIAMETER
METAL. ROOF PIPE FLASH I NG
SCALE: NONE
BIRDSCREEN
LOPE..
.Ark 2"9 C,
OUTSIDE WALL
INSULATION PER
SPECIFICATIONS
COORDINATE HYDRANT
INSTALLATION WITH
ARCHITECTURAL PLANS,
SEE SHEETS TK -A8.40
FOR KIOSK DETAILS
18"
FACE OF KIOSK
WALL HYDRANT
KEY
6" SCHEDULE
40 SLEEVE
FINISHED
GRADE /FLOOR —
15"
1
HEAT TRACE & INSULATE
WATER PIPING FROM 18"
BELOW GRADE TO BACK OF
1FREEZELESS WALL HYDRANT.
ELECTRICAL TO BE SOURCED
FROM 120V CIRCUITS
SERVING KIOSK
1173/4" TYPE K COPPER
PROVIDE MINIMUM 24" COVER
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 10 2012
City of Tukwila
BUILDING DIVISION
PLENUM AS SHOWN
ON PLANS
SELF- ADHERING RUBBERIZED
ASPHALT FLASHING
6"
PROVIDE 1/2" SPACE BETWEEN
BOTTOM OF BIRDSCREEN AND
BACK EDGE OF LOUVER TO
ALLOW DRAINAGE
I)G I
U
WEATHERPROOF LOUVER 1 NSTALLAT 1 ON
SCALE: NONE
PIPE
1" TYPE K COPPER PIPE
TYPE K COPPER SUPPLY
MAIN; SIZE AS SHOWN
ON PLAN
K 1 OSK, FREEZELESS
WALL HYDRANT
SCALE: NONE
REFRIGERANT PIPING SIZE
AS RECOMMENDED BY
EQUIPMENT MANUFACTURER
PIPE INSULATION PER
SECTION (BOTH LINES PER
MANUFACTURER'S
INSTALLATION INSTRUCTIONS)
"UNICUSHION"
VIBRATION ELIMINATING
PAD ALL SUPPORTS
UNISTRUT - LAG TO
2x6's 0 24" O.C.
PIPE CLAMP (TYP.)
NOTES:
PROVIDE PIPING SUPPORT AS SHOWN AT ALLOWABLE SPACING
AS NOTED IN SPECIFICATIONS FOR PIPE HANGERS.
COVER ENTIRE LENGTH OF EXPOSED PIPING ON EXTERIOR WALL
W/ 24 GA. GALV. SHEET METAL FLASHING. (2) COATS PRIMER,
(1) COAT EPDXY PAINT
REFRIGERANT PIPING ON' "ECEIVED
AU6 22 2012
PERMIT CENTER
EXTERIOR WALL
SCALE NONE
No.
Date
By
Chk.
App.
Revisions
Designed By
scs
Drawn By
IMP
Checked By
DMM
Approved By
WYL
Consulting Engineers
1601 Fifth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622 -5822 Fax (206) 622 -8130
T R E S W E S T
ENGINEERS ,INC.
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE (253) 472 3300
FAX (253) 472 3463.
SOUNDTRANSIT
Scale:
NO SCALE
Filename:
TK- M0.03.dwg
Contract No.:
RTA /CP 0101 -05
Submitted:
Date:
Approved:
Date:
Date:
06/15/12
SOU
\3 TRA \S.T TU
90% PERK
<WILA STAT 0\
TU <W LA, WASH \GTO\
MECHAN I CAL DETAILS
IT SJBV
Drawing No.:
TTAL
TK -MO.03
Sheet No.: Rev.:
288
•
•
•
3" SCHEDULE 80
STAINLESS STEEL
DOWNSPOUT O (SIM.)\
3" SCHEDULE 80
STAINLESS STEEL
DOWNSPOUT
i
(SIM.)
EXTEND PIPING 5'
BEYOND
FOUNDATION (TYP.)
SEE CIVIL PLANS FOR
CONTINUATION (TYP.)
3" SCHEDULE 80
STAINLESS STEEL
DOWNSPOUT O (SIM.)
TRANSIT SHELTERS
SCALE: I /16" = I' -0"
TK —M1.00
IJ
3" SCHEDULE 80
STAINLESS STEEL
DOWNSPOUT O
PARATRANSIT SHELTER
SCALE: I /16" = I' -0"
3" SCHEDULE 80
STAINLESS STEEL
DOWNSPOUT O
TK —M1.00
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 10 2012
City of Tukwila
BUILDING DIVISION
STRUCTURAL
COLUMN
PLAN NOTES
0 DOWNSPOUTS — SEE DETAIL 4 /TK —M1.00 & ARCHITECTURAL
DETAILS 8/TK —A8.15 AND 11/TK—A8.15
UP TO GUTTER; SEE
,.� ARCHITECTURAL DETAIL
11/TK—A8.15
3" SCHEDULE 80
STAINLESS STEEL PIPE
i
STRAP
f CLEANOUT
SEAL
STAINLESS
STEEL SLEEVE
CONNECT TO DOWNSPOUT
CONNECTOR AND DOWNSPOUT
TIGHTLINE; SEE CIVIL PLAN
TK —DR.02 & ARCH DETAIL 8/A8.15
DOWNSPOUT CONNECTION
SCALE: I /16" = I ' -0"
TK —M1.11
TK= .14 TK -M1.24
%' Br
`II'1 II
II\
1
1
1
1
000000000000 0000000 0 00000000000000 000
000000000000000 000006000000000000000000 00000000000000000000
0 0000000 Oa 0 0 00 00 000 0 000
MECHANICAL SITE PLAN
SCALE: 1" = 40'
Designed By.
scs
Drawn By
TMP
Checked By
DMM
irrEfirel Consulting Engineers
1601 Fifth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622- 5822 Fax (206) 622 -8130
Approved By
WYL
No.
Date
By
Chk.
App.
Revisions
06/1
T R E S W E S T
TK —M1.00
Scale:
In
40' -0"
P6 tfoximp- 160
40 20 0 40
ED)
80
SCALE IN FEET
907 P
SOU \3 TRA \ST TUKWLA STAT
TU < :W LA, WAS \ G TO \I
ENGINEERS ,INC.
Filename:
TK —M 100.dwg
Submitted:
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE (253) 472 3300
FAX (253) 472 3463
SOUNDTRANSIT
Contract No.:
RTA /CP 0101 -05
IRV
0\
TK —M1.21
RECEIVED
AUG 2 22012
PERMIT CENTER
IT SJBV I TTAL
Drawing No.:
TK -M 1.00
MECHAN I CAL SITE PLAN
Sheet No.:
Rev.:
Date:
Approved:
Date:
Date:
06/15/12
E
•
•
UNISTRUT (2)
CH -1.
\- UNISTRUT (2)
FLEXIBLE CONNECTION
(TYP.)
CONNECT TO STRUCTURE;
SEE STRUCTURAL PLANS
FOR STRUCTURE TYPE
(TYP.)
VIBRATION ISOLATOR
(TYP.)
BOTTOM RETURN OPENING
CEILING - MOUNTED FAN OR.
CAB 1 NET HEATER 1 NSTALLAT 1 ON
SCALE: NONE
410 OUTSIDE AIR
CONNECTION
0 32/12 PL
INDOOR AIR HANDLER OUTSIDE
AIR CONNECTION TO LOUVER
SCALE: NONE
REVIEWED FOR
CODE CO CE
APPROVED
SEP1021
City of Tukwila
BUILDING DIVISION
014/12 WP
U -1
›- REFRIGERANT
PIPING
AC -1
0
X12/6
32/12 WPL
8/8 WTG BOTH SIDES
W/ SHEETMETAL SLEEVE)
.CFSD
'r'-aVaNIT 4
CONIENSATE
DRAIN PIPING
2/12 WPL
/8 WTG BOTH SIDES
v/ SHEETMETAL SLEEVE)
12/6
8/6
ED BDD
3 EF -1 - DD ::
130 CFM
8/6
EF -2
130
8
17-- FILTER RACK E
W/ 1" FILTERS
0 EH -3
H
RETURN ON
BTM OF UNIT
0 32/12 WPL
-4--
16/8
SOUNDLINED
..._'
8/6
)Lif �J
r'�'
1
r - -1 6/
10
.f
- 8/4
CFM
'6 EGH
0 CFM
6/6 EGH
30 CFM
16/8
SOUNDLINED
I
1 /8 SWSGI
2 0 CFM
16/8 TG BOTH IDES
IN/ SHEETMETAL
SLEEVE (TYP.)
ANC 1 LLARY BU 1 LD 1 N G— M ECH AN 1 CAL PLAN
SCALE: 1 /4" = 1 I - 0 "
PLAN NOTES
O LOUVER IS TO FIT INTO FRAME; SEE SHEET TK- A10.11FOR
EXACT SIZE AND LOCATION. SEE DETAIL 7 /TK -M0.03 FOR
PLENUM REQUIREMENTS
® SEE SHEET TK -A4.11 FOR EXACT LOCATION
0 MOUNT EQUIPMENT SO AS TO PROVIDE MAXIMUM HEAD
HEIGHT AVAILABLE
04 7 -DAY PROGRAMMABLE
CONDENSATE PIPING
DN TO SERVICE SINK
- CEILING ACCESS
PANEL; SEE
SHEET 5/A2.11
f)&tizumw bo
TK—M 1 .00
4
SCALE IN FEET
8
RECEIVED
AUG 22 2012,
PERMIT CENTER
90% P_R
V
T SUB
TTAL
Designed By
sc$
Drawn By
TMP
No.
Date
By
Chk.
App.
Revisions
Checked By
DMM
Approved By.
WYL
Mil Consulting Engineers
1601 Fifth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622--5822 Fax (206) 622 -8130
TRES WEST
ENGINEERS ,INC.
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE (253) 472 3300
FAX (253) 472 3463
SOUNDTRANSIT
Filename:
TK —M 1 I .dwg
Submitted:
Date:
Approved:
Date:
Contract No.:
RTA /CP 0101 -05
Date:
06/15/I2
SOJ
\3 TRANSIT TJ /<WILA• STATION
TU <WI LA, WASH
GTON
ANCILLARY ABU I LD I NG - MECHAN I CAL
Drawing No.:
TK -M 1.0.I
Sheet No.:
290
Rev.:
•
E
E
H
2" AREA DR IN
3 "0 STAIN SS STEEL
DOWNSP T UP TO GUTTER
(REF. ' - A5.21) & DOWN TO
STO (REF. DK- DR.02) O
.2
M0.03
P- LECTRONIC TRAP
PRIMER; k CCESS FROM
JANITOR RO'
/2 "CW
3 /4 "HW
P -5
o4" 2 -WAY SCO
16' -2"
1"CAP
FOR FUTURE
'3 /4 "CW
AREA DRAIN TO STORM; ,
SEE TK -DR.02 & TK- UC.02`
T &P: DRAIN FULL SIZE TO
SERVICE SINK P -5
1 -1 /2 "NON - POTABLE WATER
TO SITE; FOR CONTINUATION
SEE SHEETS TK -M1.11
THROUGH TK -M1.14
FIRE SPRIN
SEE SHEET
FOR FIRE SPRI
PLAN & DETAILS
AP
RIMER
VALVE
2 "V
4 "V UP TO 4 "VTR
2 "V
M0.03
FWH-
2" AREA DRAIN
1' -8"
3 "0 ST
DOWNSP
(REF.
STORM (RE
• POC
1
5' -0" TO BLDG
EDGE (TYP.)
0 r(6 STAINLESS STEEL
DOWNSPOUT UP TO GUTTER
(REF. TK- A5.21) & DOWN TO
STORM (REF. DK- DR.02)
. POC
FOR CON TINUA11O 1
SEE TK -UC.02
2"STORM UP TO
DRAIN
L�
2 "DOMESTIC
CW SERVICE
POC;
. 4" 2 -WAY SCO
•
5' -0" TO BLDG
EDGE (TYP.)
g POC,
FIRE PROTECTION SUPPLY, SEE
SHEET TK -M1.03 FOR FIRE
SPRINKLER PLAN & DETAILS
AREA DRAIN TO STORM;
SEE TK -DR.02 & TK -UC.02
P-6 ELECTRONIC TRAP
PRIMER; ACCESS FROM
STORAGE ROOM
INLESS S
sUT UP
TK 5.21)
ANC I LLAkY BUILDING -
PLUMB•I NG
PLAN
. POC
F
4 "SS
L_
f
FIRE SERVICE
0 3 "0 STAINLESS STEEL
DOWNSPOUT UP TO GUTTER
(REF. TK- A5.21) & DOWN TO
STORM (REF. DK- DR.02)
SCALE: 1/4" = 1' -0"
TKM1.0 0
l
4 ".
2 -WAY
SCO
5' -0"
r-- - - - 1
1 1
1 1
f4 4
PLAN NOTES
O 1 -1/2 "RPBP FOR NON- POTABLE CW TO SITE
® FIRE SPRINKLER STANDPIPE DRAIN, SEE SHEET TK -M1.03
FOR FIRE SPRINKLER PLAN AND DETAILS
2 "-\
DOWNSPOUTS - SEE DETAIL 4 /TK -M1.00 & ARCHITECTURAL
DETAILS 8/1X -A8.15 & 11 /TK -8.15
ROOF
4'- - --
1 - --
CEILING
2FU.
2 "FD
2 "-i 2 "Th 2 "- 2 "-•*,1
2FU
HALL
2 "FD
2FU
2 "FD
2FU
STO
2 "FD
POC S\
1 -1/2 "NON- POTABLE
WATER UP
4 "S�. U
2 "S
4 "SS UP
UP WCO
2 "STORM UP
TO AREA
DRAIN
di
4 "-
2FU
2"
2"
2FU
P- 2A
Co
2-�
1FU
RR
P -3A^
CO%
2"
2"
3FU
2 "FCO P =5
WCO I I\
FINISHED
FLOOR
2"
3
4" „
/
4 "- 2�p 12 4 "2 ® �j 4 "/
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 10 2012
City of Tukwila
BUILDING DIVISION
1 -1/2 "NON- POTABLE CW
WATER TO SITE, FOR
CONTINUATION SEE SHEET
TK -M
ANC I LLARY BU I LD 1 NG - FOUN TAT ION PLAN
SCALE: 1/4" = 1' -0"
SANITARY SEWER AND VENT RISER DIAGRAM
SCALE: DIAGRAMMATIC
2
TK—M1.0 0
SCALE IN FEET
i
90% P
TK —M1.02
RECEIVED
AUG 222012
PERMIT CENTER
-RvIT SUB
V TTAL
Designed By.
scs
Drawn By.
TMP
No.
Date
By
Chk.
App.
Revisions
Checked. By
DMM
Approved By.
WYL
IMIN Consulting Engineers
1601 Fifth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622 -5822 Fax (206) 622 -8130
T R E S W E S T
ENGINEERS ,INC.
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE (253) 472 3300
FAX (253) 472 3463
SOUNDTRANSIT
Scale:
1/4" = I 1 -0"
Filename:
TK —M 1.02.dwg
Contract No.:
RTA /CP 0101 -05
Submitted:
Date:
Approved:
Date:
Date:
06/15/12
SOU\
TRANSIT TUKWILA STAT O\
TJ <W LA; WASH \ GTO \
ANCILLARY BUILDING - PLUMBING
Drawing No.:
TK -M 1.02
Sheet No.:
29I
Rev.:
•
•
FOR CONTINUATION
SEE TK —UC.02 2 1 F
POC
5' -0" TO
BLDG EDGE
FIRE PROTECT •N
SUPPLY MAIN
FIRE SPRINKLER
HEADER STANDPIPE
DRAIN
1 IRE DEPARTMENT
ONNECTION 42" ABOVEw
INISHED GRADE
0
FIRE
SPRINKLER
HEADER
1-
7,..J: T ,00
4,--
- _ ,
3�
M1.03�.
ANCILLARY BUILDING
FIRE SPRINKLING PLAN
6 "0 STANDPIPE DRAIN FOR
FIRE SPRINKLER SYSTEM
BRACKET
2 "VENT PIPE
BRACKET
WATER MOTOR GONG
OUTSIDE, WALL -
- STRAP TO WALL. COORDINATE
WITH FIRE SPRINKLER
CONTRACTOR
4" WASTE
30"
FLOOR
PROVIDE P —TRAP
WITH TRAP PRIMER
FIRE SP_R I NKLER HEADER
STANDPIPE DRAIN DETAIL
SCALE: NONE
SCALE: 1/4" = I' -0"
TK -M1.00
FIRE
DEPARTMENT
CONNECTION
F
r F
CHECK VALVE
FIRE SPRINKLER
HEADER STANDPIPE
DRAIN
rJ
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 10 2012
City of Tukwila
BUILDING DIVISION
STRAINER
f F TO BUILDING
i,e:
RETARD CHAMBER WITH
PRESSURE SWITCH
MAIN DRAIN AND FLOW
jTEST VALVE
- WET PIPE ALARM CHECK VALVE
AND PRESSURE GAUGES
- -4'
F "W
L J
FIRE PROTECTION
SUPPLY MAIN 5--- -F
TO FIRE
ALARM PANEL
OS & Y VALVE WITH TAMPER SWITCH
DOUBLE DETECTOR CHECK
VALVE ASSEMBLY
PROVIDE STEEL PIPE
SLEEVE (TYPICAL) EXTEND
1 "ABOVE FINISHED FLOOR.
INSTALL WITH LINK SEALS
NOTES
1. PROVIDE PIPE SUPPORTS AND. ANCHORS AS REQUIRED
TO SUPPORT ENTIRE VALVE ASSEMBLES.
2. THIS DIAGRAM IS PRESENTED AS AID TO CONTRACTOR.
IT DOES NOT RELIEVE CONTRACTOR FROM MEETING ALL
REQUIREMENTS OF NFPA 13 AND LOCAL AUTHORITIES.
FIRE SPRINKLER HEADER DIAGRAM
SCALE: NONE
PLAN NOTES
0 COORDINATE PENETRATION SIZE AND LOCATION WITH
STRUCTURAL ENGINEER
FIRE SPR I NKL I NG GENERAL NOTES
1. DESIGN, FURNISH AND INSTALL A COMPLETE "WET PIPE" AUTOMATIC SPRINKLING SYSTEM
FOR THE ANCILLARY BUILDING INCLUDING AREAS ABOVE AND BELOW CEILINGS, ATTIC
SPACES, INTERSTITIAL SPACES. THE AUTOMATIC SPRINKLER SYSTEM SHALL BE DESIGNED
AND INSTALLED IN ACCORDANCE WITH NFPA 13 . (IBC 903.31 STANDARDS), IBC, IFC AND
ALL LOCAL CODES AS A MINIMUM STANDARD. ADDITIONAL REQUIREMENTS ARE NOTED IN
THE SPECIFICATIONS OR IN THESE DRAWINGS.
2. PROVIDE COVERAGE FOR THE ENTIRE ANCILLARY BUILDING INCLUDING AREAS ABOVE AND
BELOW CEILINGS, ATTIC SPACES, MEZZANINES, INTERSTITIAL SPACES, OVERHANGS AND
MECHANICAL /ELECTRICAL ROOMS. THE ASSUMPTION OF FIRE ALARM DEVICES OR SYSTEMS
BEING INSTALLED DOES NOT RELIEVE THE FIRE SPRINKLING CONTRACTOR OF PROVIDING
COVERAGE IN ALL AREAS.
3. THE INTENT OF THIS DRAWING IS TO SHOW THE ROUTING OF THE LARGER FIRE SPRINKLER
MAIN IN CRI11CAL AREAS. ALL PIPING SHALL BE CONCEALED EXCEPT FOR WHERE NOTED
ON THIS DRAWING. ANY DEVIATIONS IN THE FIRE MAIN LAYOUT SHOWN HERE SHALL BE
APPROVED BY THE ARCHITECT DURING SUBMITTAL PROCESS BEFORE INSTALLATION AND
SHALL BE AT NO ADDI110NAL COST TO THE OWNER. NO EXPOSED. PIPING WILL BE
ALLOWED IF, IN THE BUILDING STRUCTURE, THE ARCHITECT HAS PROVIDED SHAFTS,
FURRED AREAS, OR CONCEALED SPACES WHERE PIPING COULD BE HIDDEN FROM VIEW.
DO NOT RUN PIPING OVER ELECTRICAL PANELS OR SWITCHGEAR: EXCEPT WHERE LOCATED
ABOVE THE STRUCTURAL CEILING.
4. FIRE SPRINKLER MAIN NOT SHOWN SHALL BE LAID OUT PER FIRE SPRINKLER COVERAGE
REQUIREMENTS. SEE ARCHITECTURAL DRAWINGS FOR AREAS NOT SHOWN OR FOR
MULTIPLE FLOORS THAT REQUIRE FIRE SPRINKLING COVERAGE.
5.. THE FIRE SPRINKLER CONTRACTOR SHALL COORDINATE THE LOCATION OF THE PIPING AND
HEADS TO AVOID INTERFERENCES WITH LIGHT FIXTURES, HEATING /COOLING EQUIPMENT,
DUCTWORK AND ANY ARCHITECTURAL FEATURES SUCH AS EXPOSED SLOPE ROOF
STRUCTURES, SKYLIGHTS, STAIRWAYS, ETC. IN CATWALK AREAS, PIPING SHALL BE RUN
AS HIGH AS POSSIBLE TO ALLOW THE MAXIMUM HEADROOM OVER THE MECHANICAL
EQUIPMENT AND AISLE SPACES. MAXIMUM CLEARANCE SHALL BE MAINTAINED FOR
SERVICE ACCESS AND MAINTENANCE FOR ALL EQUIPMENT. FAILURE TO COORDINATE
SHALL BE JUSTIFICATION TO REQUIRE THE FIRE SPRINKLER CONTRACTOR, AT HIS OWN
EXPENSE, TO MOVE AND REDO HIS WORK.
6. IT SHALL BE THE FIRE SPRINKLER CONTRACTOR'S FULL RESPONSIBILITY TO INSTALL A
COMPLETE WORKING SYSTEM MEETING ALL CODES.
7. COORDINATE ALL SPRINKLER HEAD LOCATIONS WITH LIGHTING, MECHANICAL, AND ALL
OTHER CEILING APPURTENANCES. SEE TK— A2.11, TK— M1.01, & TK —E2.11
SCALE IN FEET
90% P
v
RECEIVED
AUG 22 2012
PERMIT CENTER
IT SUB
VI I TT AL
No.
Date
By
Chk.
App.
Revisions
Designed By
scs
Drawn By.
TMP
Checked By
DMM
Approved By
WYL
ERR Consulting Engineers
1601 Fifth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622 -5822 Fax (206). 622 -8130
T R E S W E S T
ENGINEERS ,INC.
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE (253) 472 3300
FAX (253) 472 3463.
SOUNDTRANSIT
Scale:
/4'
= 1 1-0"
Filename:
TK —M 1 .03.dwg
Contract No.:
RTA /CP 0101-05
Submitted:
Date:
Approved:
Date:
Date:
06/15/12
SOU \3 TRA \SIT T,
,<WILA STAT O\
TU <WILA, WASH \ GTO
ANCILLARY BUILDING - FIRE
SPRINKLING
Drawing No.:
TK M 1.03
Sheet No.:
292
Rev.:
A
•
H
1
1 "NON— POTABLE CW
4
1
PLAN NOTES
0 1" NON - POTABLE CW UP TO KIOSK NON— FREEZE WALL BOX HYDRANT;
SEE DETAIL 4 /TK —M0.03
PARTIAL BELOW GRADE PLAN 1 - MECHAN I CAL
SCALE: 1/8" = V-0"
1 "NON— POTABLE CW
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 10 2012
City of Tukwila
BUILDING DIVISION
1
TK—M1.0 0
1
L J
KEY PLAN
0 8
16
SCALE IN FEET 90% PER
V
RECEIVED
AUG 22 2012
PERMIT CENTER
IT SUB
VIITTAL
Designed By
scs
Drawn By
TMP
No.
Date
By
Chk.
App.
Revisions
Checked By
DNN
Approved By
WYL
Consulting Engineers
1601 Fifth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622 -5822 Fax (206) 622 -8130
Submitted:
Date:
T R E S W E S T
ENGINEERS ,INC.
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE -(253) 472 3300
FAX (253) 472 3463
Approved:
Tie
SOUNDTRANSIT
Date:
Filename:
TK —M I.1 I .dwg
Contract No.:
RTA /CP 0101 -05
Date:
06/15/12
SOU \3 TRA \SIT TJKWILA STAT
T, <W LA, WASH \GTO\
PARTIAL BELOW GRADE PLAN I
MECHANICAL
0\
Drawing No.:.
TK -M I.I
Sheet No.:
293
• Rev.:
SEE DWG TK -M1.11
1
I
I
1
1
I
1
1
1
1
1
\--1 NON—POTABLE CW
\-1-1/2 NON—POTABLE CW
Iw
w
I(/).
1
1
1
1
1
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 10 2012
City of Tukwila
BUILDING DIVISION
1
1
0 I—
1
0 1
w
w
PARTIAL BELOW GRADE PLAN 2
SCALE. :1 /8" = 1' -0"
MECHANICAL
1 "NON— POTABLE CW
� 1
TK —M1.00
111
—1 /2 "NON — POTABLE CW
PLAN NOTES
0 in NON— POTABLE CW UP TO KIOSK NON — FREEZE WALL BOX HYDRANT;
SEE DETAIL 4 /TK —M0.03
1)G144.- l(pc)
1
1
1
1
1
1
1
1
1
1
KEY PLAN
0 8
16
No.
Date
By
App.
Revisions
Designed By
SCS
Drawn By:
TMP
Checked By
DMM
Approved By
WYL
06/1
EIZE14. Consulting Engineers
1601 Fifth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622 -5822 Fax (206) 622 -8130
T R E S W E S T
ENGINEERS ,INC.
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE` (253) 472 3300 ..
FAX (253) 472 3463
L'
SOUNDTRANSIT
Scale:
1/8"
Filename:
TK —M I.12.dwg
Contract No.:
RTA /CP 0101 -05
Submitted:
Date:
Approved:
Date:
Date:
06/15/12
SCALE IN FEET 9070 PER V
SOU \D TRA \SIT TJKWILA STAT O\
TJ�WI�A, WASH \GTO\
PARTIAL BELOW GRADE PLAN 2 -
MECHANICAL
RECEIVED
AUG 222012
PERMIT CENTER
IT SUBV
TTAL
Drawing No.:
TK -M I. 12
Sheet No.:
294
Rev.:
0
01
W
wl
(n
1
i
r FOR CONTINU;
SEE SHEET TI
TI ON
-M1.02
—1/2"NON—POTABLE CW -
—1/2"NON—POTABLE CW
/ 2 "NON - POTABLE CW
—1/2 NON—POTABLE CW
J
1
1
1
1
1
1 -1 /2 "NON— POTABLE CW IN
CASING - SEE TK —UC.05
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 1 0 2012
City of Tukwila
BUILDING DIVISION
1
1
1
NI
I1
j-1
C� 1
�1
0IW
1 -1 /2 "NON— POTABLE CW
1
PART I 'AL BELOW GRADE PLAN 3
SCALE: 1/8" = 1' -0"
MECHANICAL
rTh
TK--M1.00
—1/2"NON—POTABLE CW
PLAN NOTES
0 1" NON— POTABLE CW UP TO KIOSK NON— FREEZE WALL BOX HYDRANT;
SEE DETAIL 4 /TK —M0.03
PG100147-
1
0
to
Iw
W
rn
KEY PLAN
0 8
16
SCALE IN FEET
90% P -RV
Designed By
SCS
Drawn By
TMP
Checked By.
DMM
No.
Date
By
Chk. App. Revisions
Approved By
WYL
DEMConsulting Engineers
1601 Fifth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622 -5822 Fax (206) 622 -8130
T R E S W E S T
ENGINEERS ,INC.
2702 SOUTH. 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE (253) 472 3300
FAX (253) 472 3463
T
SOUNDTRANSIT
Scale:
811
= I' -0"
Filename:
TK
M I.13.dwg
Contract No
RTA /CP
0.101 -05
Submitted:
Date:
Approved:
Date :.
Date:
06/1 5/1 2
SO
\D TRANSIT TUKWILA STAT
TU <W LA, WAS I \ GTON
PARTIAL BELOW GRADE PLAN 3 -
MECHANICAL
0\
RECEIVED
AUG 22 2012
PERMIT CENTER
T SUBV I TTAL
Drawing No.:
TK -MI.I3
Sheet No.:
295
Rev.:
• C •
3” SCHEDULE 80 STA NLESS
STEEL DOWNSPOUT UP;
CONTINUED ON SHEET TK —M1.14
NFBH; SEE
TI< -A2.12 FOR
EXACT LOCATION
(SIMILAR)
6
MO.3
1
1
1 3" SCHEDULE 80 STAINLESS
STEEL DOWNSPOUT; ROUTE
UNDER SLAB ABOVE
1
1 1NON— POTABLE CW
1 1
1
1 i
3" SCHEDULE 80 STAINLESS
BICYCLE CAGESTEEL DOWNSPOUT; ROUTE
UNDER SLAB ABOVE
3" SCHEDULE 80 STAINLESS
STEEL DOWNSPOUT .UP;
CONTINUED ON SHEET TK —M1.14
3" SCHEDULE 80
STAINLESS STEEL
DOWNSPOUT
3" SCHEDULE 80
STAINLESS STEEL
DOWNSPOUT®
3" SCHEDULE 80 STAINLESS
STEEL DOWNSPOUT; ROUTE
UNDER SLAB ABOVE; CIVIL TO
CONNECT TO TRENCH DRAIN
PIPING, REF. TK —DR.05
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 10 2012
City of Tukwila
BUILDING DIVISION
O `)
O 0
O 0
O 0
O 0
O 0
O 0
O 0
O 0
POTABLE CW
PLAN NOTES
0 1" NON - POTABLE CW UP TO KIOSK NON— FREEZE WALL BOX HYDRANT;
SEE DETAIL 4 /TK —M0.03
PART I AL BELOW GRADE PLAN 4 MECHAN I CAL
SCALE: :1 /8" = 1' -0"
(Thi
rK— M1.00
KEY PLAN sN
4 16
SCALE IN FEET
No. Date
App.
Revisions
Designed By
scs
Drawn By.
TMP
Checked By
DMM
Scale:
Approved By
WYL
Consulting Engineers
1601 Fifth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622 -5822 Fax (206) 622 -8130
T R E S W E S T
ENGINEERS ,INC.
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE (253) 472 3300
FAX (253) 472 3463
$OUNDTRANSIT
Filename:
TK —M I.14.dwg
Contract No.:
RTA /CP 0101 -05
=RVIT SUBV TTAL
Drawing No.:
TK -M 114
SOJ \D TRA \S T T „KWILA STAT O\
T <WI LA, WAS \ GTO\
Submitted:
Date:
Approved:
Date:
Date:
PARTIAL BELOW GRADE PLAN 4 -
MECHANICAL
Sheet No.: Rev.:
06/15/12
A
•
•
•
I N
N
I'
1 0
Ic
JLU
W
i
1
1
S--2)
1
1
1
PLAN NOTES
KIOSK NON- FREEZE WALL BOX HYDRANT; SEE DETAIL
4/TK —M0.03
PARTIAL PLATFORM PLAN 1 MECHAN I CAL
E COMPLIANCE D FOR COD
APPRE
SEP I 0 2012
BUILDING h+ of Tukwila
DING DIVISION
p64.1.1-01610
1
SCALE: 1/8" = 1' -0"
TKM1.0 0
KEY PLAN
0 8
16
SCALE IN FEET 90% PER
V
4 ,ECEIVED
AUG 222012
PERMIT CENTER
T SUB
V ITTAL
No.
Date
By
Chk.
App.
Revisions
Designed By
SCS
Drawn By
TMP
Checked By
DNN
Approved By
WYL
Consulting Engineers
1601 Fifth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622 -5822 Fax (206) 622 -8130
TRES WEST
ENGINEERS ,INC
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE (253) 472 3300
FAX (253) 472 3463
SOUNDTRANSIT
Scale:
/8" = II_OII
Filename:
TK —M I.21.dwg
Contract No.:
RTA /CP 0101 -05
Submitted:
Date:
Approved:
Date:
Date:
06/15/12
SOU\
3 TPA \S IT TUKWILA STAT O
TU <W LA, WASH N GTO
PARTIAL PLATFORM PLAN I -
MECHANICAL
Drawing No.:
TK -M 1.21
Sheet No.:
297
Rev.:
1
1
•
■
i
■
I�I�I�I�I�I
0
3" SCHEDULE 80.
STAIN ESS STEEL,
0 • -.1
o�—
®1.1■I1.1®
.1=1=1 ■
3" SCHEDULE 80
STAIN ESS STEEL
1 • " •POUT,
STAINLESS STEEL
3" SC
STAIN
EDULE 80
SS STEEL
;OUT�1
1
1
1
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 10 2012
City of Tukwila
BUILDING DIVISION
.w.w
I- Iw._ .e
CI —I�I�I
11 ■
11
i
111
111
IN
®ICI WI `=C=
1111010".1111
a
3" CHEDULE 80
STA NLESS STEEL
DOWNSPOUT 0 .
PARTIAL PLATFORM PLAN 2 MECHAN I CAL
SCALE: 1/8" = 1' -0"
3"' SCHEDULE 80
STA NLESS STEEL
DOWNSPOUT
PLAN NOTES
3" SCHEDULE 80
TAINLESS STEEL
• „ •7.�e ■mow
KIOSK NON— FREEZE WALL BOX HYDRANT; SEE DETAIL
" 4 /TK —M0.03
0 DOWNSPOUTS — SEE DETAIL 4 /TK— M1.00, & ARCHITECTURAL
DETAILS 8/TK —A8.15 AND 11/TK— A8.15. CONNECT TO
STORM DRAINAGE, REF. TK —DR.02 THRU TK —DR.06
1
1
i
1
1
1
3" SCHEDULE 80
STA NLESS STEEL
DOWNSPOUT
P apo
1°
w
w
KEY PLAN
0 8
16
SCALE IN FEET
No.
Date
By
Chk.
App.
Revisions
Approved By
WYL
06/1
MrgConsulting Engineers
1601 Flfth . Avenue, Suite 1600
Seattle, Washington 98101
(206) 622 -5822 Fax (206) 622 -8130
TRES WEST
ENGINEERS ,INC.
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE (253) 472 3300
FAX (253) 472 3463
SOUNDTRANSIT
Scale:
Contract No.:
RTA /CP 0101 -05
Submitted:
Date:
Approved:
Date:
Date:
06/15/12
S0 „ \3 TRA \SIT TU
K
TU K W LA, WAS
90% PERV
WI LA STAT 0\
\GTO\
PARTIAL PLATFORM PLAN 2 -
MECHANICAL
w
fl
ECEIVEID.
AUG 222012
PERMIT CENT& .
IT
SUBV
Drawing No.:
TTAL
Sheet No.:
N
N
•
uJ
W
■
A.,
3" SCHEDULE 80
STAINLESS STEEL
DOWNSPOUT O
3" SCHEDULE 80
STAINLESS STEEL
DOWNSPOUT
1
1
1
W
W
1
1
1
1
1
I
I
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 1 0 2012
BUILDING of Tukwila
DIVISION
NI
PART 1 AL PLATFORM PLAN 3 - MECHAN 1 CAL
SCALE: 1/8" = 1' -0„
EMI
0
L uU
P
I
3" SCHEDULE 80 • •
STA NLESS STEEL
DOWNSPOUT
TK—M1.0 0
3" SCHEDULE 80
STAINLESS STEEL
DOWNSPOUT
P6101 iv)
PLAN NOTES
O1 KIOSK NON— FREEZE WALL BOX HYDRANT; SEE DETAIL
4 /TK -M0.03
0 DOWNSPOUTS — SEE DETAIL 4 /TK —M1.00 & ARCHITECTURAL
DETAILS 8/TK —A8.15 AND 11/TK— A8.15. CONNECT TO
STORM DRAINAGE, REF. TK —DR.02 THRU TK —DR.06
KEY PLAN
0 8
16
Designed By
scs
Drawn By
TMP
No.
Date
By
Chk.
App.
Revisions
Checked By
DMM
Approved By
WYL
eirEIN Consulting. Engineers
1601 Fifth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622 -5822 Fax (206) 622 -8130
T R E S W E S T
ENGINEERS ,INC.
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE (253) 472 3300
FAX (253) 472 3463
SOUNDTRANSIT
Scale:
1 /8" = 11-0"
Filename:
TK -M I.23.dwg
Contract No.:
RTA /CP 0I0I -05
Submitted:
Date:
Approved:
Date:
Date:
06/15/12
SOU
SCALE IN FEET 90% PER
v
IT
RECEIVED
AUG 2 2 2012
PERMIT CENTER
S B
V TTA L
TRA \S T TUKWILA STATIO\
TUKWILA, WAS \ G TO \
PARTIAL PLATFORM PLAN 3 —
MECHANICAL
Drawing No.:
TK -M 1.23
Sheet No.: Rev.:
299
3" SCHEDULE 80 STAINLESS
STEEL DOWNSPOUT;. CONNECT
TO GUTTER & SEE SHEET
TK —M1.14 FOR CONTINUATION
3" SCHEDULE 80 STAINLESS
STEEL DOWNSPOUT; CONNECT
TO GUTTER & SEE SHEET
TK —M1.14 FOR CONTINUATION
- 3" SCHEDULE 80
—STAI SATE -EL-
DOWNSPOUT
3 "0 STAINLESS STEEL
DOWNSPOUT UP TO, GUTTER
(TK —A2.13 & TK— A7.13).
DAYLIGHT TO —GRAD
�- 3 "0 STAINLESS STEEL
DOWNSPOUT UP TO GUTTER
(TK —A2.13 & TK— A7.13) &
DOWN TO STORM (TK— DR.05)
3" SCHEDULE 8
STANLESS—S
DOWNSPOUT
SEP 10 2012
4
TA NLESS STEEL
OWNSPOUT O
3 SCHEDULE 80
STAINLESS STEEL
PART 1 AL PLATFORM PLAN 4 MECHAN 1 CAL
SCALE: 1/8" = 1. -0„
TK—M1.00
PLAN NOTES
O KIOSK NON--FREEZE WALL BOX HYDRANT; SEE DETAIL
4/TX—M0.03
O DOWNSPOUTS — SEE DETAIL 4 /TK —M1.00 & ARCHITECTURAL
DETAILS 8/TK -A8.15 AND 11/TK—A8.15. CONNECT TO STORM
DRAINAGE, REF. TK —DR.02 THRU TK -DR.06
0 DAYLIGHT TO TRENCH DRAIN; REF. TK —DR.05
RECEIVED
AUG 2 2 2012
PERMIT CENTER
0-'R9il 1-110.9i1
•
IA,- 160
KEY PLAN
4 0 8
SCALE IN FEET
16
90% PER
VIIT S „B
V
Designed By.
scs
Drawn By.
TMP
Checked By
DMM
Scale:
Consulting Engineers
1601 Fifth Avenue, Suite 1600
Seattle, Washington 98101
(206) 622 -5822 Fax (206) 622 -8130
T R E S WEST
1/8
11
ENGINEERS ,INC.
2702 SOUTH 42ND STREET, SUITE 301
TACOMA, WA 98409 -7315
TELEPHONE (253) 472 3300
FAX (253) 472 3463
SOUNDTRANSR
Filename:
TK —M 1 .24.dwg
Contract No.:
RTA /CP 0101 -05
SOU \ D TR A \SIT TL K WI LA STATIC'
T„ KWI LA, WASH \ GTO\
TTAL
Drawing No.:
TK -M I .24
Approved By
WYL
No.
Date
By
Chk.
App.
Revisions
Submitted:
Date:
06/1
Approved:
Date:
Date:
PARTIAL PLATFORM PLAN 4 -
MECHAN I CAL
Sheet No.:
300
Rev.:.
06/15/12