HomeMy WebLinkAboutPermit PG12-160 - SOUND TRANSIT SOUNDER STATIONSOUND TRANSIT SOUNDER STATION 7301 LONGACRES WY PG12 -160 City oirI'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov PLUMBING /GAS PIPING PERMIT Parcel No.: 2423049029 Address: 7301 LONGACRES WY TUKW Project Name: SOUND TRANSIT SOUNDER STATION Permit Number: Issue Date: Permit Expires On: PG12 -160 09/23/2013 03/22/2014 Owner: Name: UNION PACIFIC RAILROAD CO Address: PROPERTY TAX , 1400 DOUGLAS STOP 1640 68179 Contact Person: Name: Address: Email: Contractor: Name: Address: KYM WILLIAMS 401 S JACKSON ST , SEATTLE WA 98104 KYM. WILLIAMS @SOUNDTRANSIT.ORG UNIVERSITY MECH CONTR INC 11611 49TH PL W , MUKILTEO WA 98275 -4255 Contractor License No: UNIVMC *343N9 Phone: 206 - 398 -5156 Phone: 206 - 364 -9900 Expiration Date: 10/03/2014 DESCRIPTION OF WORK: INSTALL PLUMBING FIXTURES TO NEW COMFORT STATION /ANCILLARY BUILDING. Value of Plumbing /Gas Piping: Fees Collected: Electrical Service Provided by: $10,000.00 $345.19 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie xam with The granting of this permit does not pre construction or the performance of work. on the back of this permit. / f Signature: , . Print Name: t ( c,t ilr of 1 M, Uniform Plumbing Code Edition: International Fuel Gas Code Edition: 2009 2009 Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. me to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions Date: 9/?3/aW3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG12 -160 Printed: 09 -23 -2013 PERMIT CONDITIONS Permit No. PG12-160 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments. 12: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG12-160 Printed: 09 -23 -2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. -vCj (d-- (t V T1)---‘ Project No. 4 1 Date Application Accepted:) - -( 2 Date Application Expires: (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: Site Address: 7301 Longacres Way Suite Number: Floor: Tenant Name: Sound Transit PROPERTY OWNER Name: Kym Williams Address: 401 S Jackson St Name: Sound Transit Phone: (206) 398 -5156 Fax: (206) 398 -5228 Email: Icym.williams@soundtransit.org Address: 401 S Jackson St City: Seattle State: WA Zip: 98104 CONTACT PERSON — person receiving all project communication Name: Kym Williams Address: 401 S Jackson St City: Seattle State: WA Zip: 98104 Phone: (206) 398 -5156 Fax: (206) 398 -5228 Email: Icym.williams@soundtransit.org New Tenant: ❑ Yes PLUMBING CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ / U pbb Scope of Work (please provide detailed information): Install plumbing fixtures to new comfort station/ancillary building Building Use (per Int'l Building Code): B Occupancy (per Intl Building Code): Utility Purveyor: Water IIB H: Applications\Forns- Applications On Line \2011 Applications\Plumbing Permit Application Revised 8 -9 -1 l.docx Revised: August 2011 bh Sewer Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 4s Shower, single head trap 1 Sinks 1 Rain water system — per drain (inside building) I Grease interceptor for commercial kitchen ( >750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) 4s Lavatory 1 Urinal 1 Water heater and/or vent I Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial 4s Wash fountain Water closet 1 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain 4s Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1 -5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR- UTH 1 RIZE t GENT: Signature: Print Name: K illiams Mailing Address: kym.williams @soundtransit.org H:\Applications\For s- Applications On Line \2011 Applications\Plumbing Permit Application Revised 8 -9.1 I.docx Revised: August 2011 bh Date: Day Telephone: (206) 398 -5156 Seattle WA 98104 City State Zip Page 2 of 2 Cit,of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http : /hvww. ci. tukw ila. wa. us SET RECEIPT RECEIPT NO: R13 -00822 Initials: WER Payment Date: 02/15/2013 User ID: 1655 Total Payment: 236,452.44 Payee: SOUND TRANIST SET ID: 0215 SET NAME: SOUND TRANSIT SET TRANSACTIONS: Set Member Amount D12 -272 223,072.45 EL12 -0777 11,167.15 M12 -117 1,867.65 PG12 -160 345.19 TOTAL: 223,072. TRANSACTION LIST: Type Method Description Amount Payment Check 00107206 ACCOUNT ITEM LIST: Description TOTAL: 236,452.44 236,452.44 Account Code Current Pmts BUILDING - NONRES CASCADE WATER ALLIANCE ELECTRICAL PERMIT - NONR FLOOD ZONE CONTROL MECHANICAL.- NONRES PLAN CHECK - NONRES PLAN CHECK - WATER METER PLUMBING - NONRES PW LAND ALT PERMIT FEE PW PERMIT /INSPECTION FEE PW PLAN REVIEW STATE BUILDING SURCHARGE WATER CONNECTION WATER INSPECTION FEE WATER INSTALLATION (DEP) LT 'A mt1T] .TT TO TT (NTT EM, L, 000.322.100 640.237.500 000.322.101.00.0 000.322.400 000.322.102.00.0 000.345.830 000.345.830 000.322.103.00.0 000.342.400 000.342.400 000.345.830 640.237.114 401.379.002 401.342.400 401.245.100 27,561.95 84,070.00 11,167.15 50.00 1,867.65 69.04 30.00 276.15 721.00 86,895.00 17,895.00 4.50 685.00 45.00 4,965.00 A Al -311") A AC 1 CA AA t4tio INSPECTION NO. INSPECTION RECORD Retain a copy with permit F61Z -1.043 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: So0AA TrGtAci' Type Inspection: 1 Uiv • ,�� r". 1\JAL, Address: % ," o 1 L , ', Ac !PS Date Ca led: Special Instructions: Date Wanted: / 6" a:_ro: 2Z--1 p.m. Requester /tit Phone No: 8429 UApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: (1 [re. fA 0n j A4,4-6V Inspe, tor:._ Date:' 0 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. S INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Type of Ins ction: 7-",44frift/ )C,:keZe Date Called: Addr �r� S (d/ 4 r 601-, Special` nst ctions: j / Date Wanted:4P--261V,/ a P.m. Requester: Phone No: Approved per applicable codes. \Corrections required prior to approval. COMMENTS: r) etv ce.s-- ( f -,'cam, -/a oar .-, rj1 6 /S 4 — Date: L/ REINSPECTION FEE REQUIRED: Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit t&2- Oo PERMIT NO. •CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 .(206) 431-3670 Permit Inspection. Request Line (206) 431-2451 Project: i ,, 1 50uAak ( toLEV irS dUA0/4.41., Typrpf Inspection: ,,, , Ko u &t-i-- T.,h.r F t,..i ivc , Address: 7 301 Date Called: Special Instructions: • --I / Date Wanted: - I 2- -I 2._-- / Requester: ..,0" Phone,6: . LY'r !.\ -' . Approved per applicable codes. ¶j Corrections required prior to approval. COMMENTS: -I 5 () e FR_ St. Date: 2— -- (3 REINSPECTION FEE REQUI ED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd. Suite 100. Call to schedule reinspection. �*3 INSPECTION RECORD Retain a copy with permit Lo INSPECTION NO. PERMIT. N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Protect: \.___, E - u t 1o. 4.5, Typ of Inspection: P o c6 TN ( 44 Address: "73oi L , res Date Called: Special Instructions: Date Wanted: i�o _ l- /3 m a.. � ,, Requester: Phone rN 4 4 4 -0 1 Approved er applicable codes. tl Corrections required prior to approval. ` COMMENTS: D-&r - _�FGA�11 (-(o D." 7 '(. Ilispector:. Date: n REINSPECTION FEE' QU I . rior to next inspection, fee must be - paid at 6300 Southcen r Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT N0. CITY OF.TUKWILA BUILDING DIVISION Blvd., #100, Tukwila.. WA 98188 - (206) 431 -3670 Permit Inspection Request-Line (206) 431 -2451 Project: 0.-- • C\(1�k I t/-Ic.)514 Type o nspection: 6r11 - ■ Plu.;,.,A),4..>\ Address: -73o t LO- rvc�Ae)a. Date Called: f Special Instructions: • Y Date Wanted: 1 (.0 — y- 13 ate, p.m. Requester: Phone N .- Approved per applicable codes. Corrections required prior to- approval. COMMENTS: 0 - [3._r� 1 `.J I n s t ctor: Dater 0---7 n REINSPECTION FEE REQUIRED \Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 ('6R-ILno Project: .. ‘./A �.� i 7c, .�1', - Type of Inspection: f u Li e..v t,.• -JU i !� Address: ---7 1/ 1s��,�� Date Called: � Special Instructions: ( ate Wanted 2- -r�_ .. 'aim.. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: di Inspect_ n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Dater June 18, 2014 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director KymWilliams Sound Transit 401 S Jackson Street Seattle, WA 98104 -2826 RE: Request for Extension #2 Permit Number PG12 -160 Sound Transit Sounder Station — 7301 Longacres Wy Dear Mr. Williams, This letter is in response to your written request for an extension to Permit PG12 -160. The Interim Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending your permit through June 10, 2014. If you should have any questions, please contact our office at (206) 431 -3670. File: Permit No. PG12 -160 W:\Permit Centet\Extension Letters\Permits\2012\PG12 -160 Permit Extension #2.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665 SOUNDTRANSIT June 10, 2014 Mr. Bob Benidicto, PE Building Official Department of Public Works City of Tukwila 6300 Southcenter Blvd, Suite #100 Tukwila, WA 98188 Permit Extension Request for Permit #PG12 -160 Dear Mr.Benedicto, RECEIVED �;liti f1i' ►<WILA JUN 10 2014 +'ERMIT CENTER Sound Transit respectfully requests an extension of its current public works permit, #PG12 -160 for continuing construction of Tukwila Sounder Station. The permit extension will allow our contractor to continue and complete ongoing work efforts. The station is anticipated to be substantially complete this October. If you have any questions regarding this request please feel free to contact me directly via my information below. Sincerely, Kym illiams As tant Permit Administrator (206) 398 -5156 kym.williams @soundtransit.org CC: Jon O'Hare, Sound Transit Laurie Werle, City of Tukwila tif 0(0 0 IH f<'�I;If for Central Puget Sound Regional Transit Authority • Union Station 401 S. Jackson St., Seattle, WA 98104 -2826 • Reception: (206) 398 -5000 • FAX: (206) 398 -5499 www.soundtransit.org CHAIR Pat McCarthy Pierce County Executive VICE CHAIRS Julia Patterson King County Councilmember Aaron Reardon Snohomish County Executive BOARD MEMBERS Claudia Balducci Bellevue Councilmember Fred Butler Issaquah Council President Richard Conlin Seattle Councilmember Dow Constantine King County Executive Dave Earling Edmonds Mayor Dave Enslow Sumner Mayor John Marchione Redmond Mayor Joe McDermott King County Councilmember Mike McGinn Seattle Mayor Mary Moss Lakewood Councilmember Lynn Peterson Washington State Secretary of Transportation Larry Phillips King County Councilmember Paul Roberts Everett Councilmember Marilyn Strickland Tacoma Mayor Peter von, Reichbauer King County Councilmember CHIEF EXECUTIVE OFFICER Joni Earl 5/1/2014 City of Tukwila Department of Community Development KYM WILLIAMS 401 S JACKSON ST SEATTLE, WA MINNELPOLIS, MN 98104 RE: Permit No. PG12 -160 SOUND TRANSIT SOUNDER STATION 7301 LONGACRES WY Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/10/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 438 -9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 6/10/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, r } Aikr5la ennif r Marshall mitlTechnician File No: PG 12 -160 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665 September 9, 2013 Kym Williams Sound Transit 401 S Jackson St Seattle, WA 98104 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Request for Reactivation Permit Numbers M12 -117, PG12 -160 & EL12 -0777 Sound Transit Sounder Station — 7301 Longacres Wy Dear Mr. Williams, This letter is in response to your written request for reactivation of Permit Numbers M12 -117, PG12 -160 and EL12 -0777. The Building Official has reviewed your letter and considered your request to reactivate the above referenced permits. It has been determined that the City of Tukwila Building Division will be reactivating your permit applications an additional 90 days from today's date, through December 9, 2013. Once issued, a new 180 day period will start before expiration. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician File: Permit No. M12 -117, PG12 -160 & EL12 -0777 W:IPermit CenterlExtension Letters1Permits120121EL12 -0777 Permit Reactivation.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665 Bill Rambo From: Sent: To: Cc: Subject: Importance: Hi Bob — Williams, Kym <kym.williams @soundtransit.org> Friday, September 06, 2013 4:51 PM Bob Benedicto O'Hare, Jon; Bill Rambo Permit Renewals Tukwila Commuter Rail Station High Thank you so much for returning my phone message. Per your request here is my email to you asking formally for renewal /extension of trades permits M12 -117, PG12 -160, and EL12 -0777. Additionally, it may also be that the construction permit D12 -272 is expired as well as most of these permits were sent renewals simultaneously. If not too much of a trouble I request that this permit too be renewed consistent with the rest. Thank you again for your time. If any questions, do not hesitate to contact me. Have a great weekend. Kym Williams Assistant Permit Administrator Sound Transit Dept of Engineering and Construction Management P: 206 398 -5156 C: 206 473 -0910 Kym.williams @soundtransit.org e.Ck,-L.e &O v ra addilkovixt, dae, \it f0C 201'3 1 RECEIVED CITY OF TUKWILA SEP 0 6 2013 PERMIT CENTER City �f Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director ____.) 04 -02 -2013 KYM WILLIAMS 401 S JACKSON ST SEATTLE WA 98104 RE: Permit Application No. PG12 -160 SOUND TRANSIT SOUNDER STATION 7301 LONGACRES WY TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 08/22/2012, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 05/13/2013. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Pennit File No. PGI2 -160 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206- 431 -3665 1T January 29, 2013 City Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Jon O'Hare Sound Transit 401 S Jackson Street Seattle, WA 98104 -2826 RE: Request for Extensions Permit Numbers D12 -272, EL12 -0777, M12 -117, and PG12 -160 Sound Transit Sounder Station — 7301 Longacres Wy Dear Mr. O'Hare, This letter is in response to your written request for an extension to Permit Numbers D12 -272, EL12- 0777, M12 -117, and PG12 -160. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending your permits an additional 180 days from the date of expiration, through May 13, 2013. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, fivi-A.84\an shall ician File: Permit No. D12 -272, EL12 -0777, M12 -117, & PG12 -160 W :IPermit CenterlExtension LetterslPermits120121D12 -272 Permit Extension.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665 • SOUNDTRANSIT January 18`h, 2013 Jack Pace Director of Community Development Department of Community Development City of Tukwila 6300 Southcenter Boulevard, Suite # 100 Tukwila, WA 98188 • Permit Extension Request for Department of Community Development Permits M12- 117, EL 12 -0777, D12-272, and Pt- TDI-*1^ erAppL1 ED Dear Mr. Pace, S/uo/ c to Pursuant to IBC, IMC, UPC, and NEC, Sound Transit respectfully requests 90 day extensions for the following DCD permits: N C \)-` \ (.I? 0 0.t'PP -DYED 1. Building Permit D12-272 (Sounder R E , 2. Mechanical Permit M12 -1171 RCO D (L- fiJRN pwcv; 3. Electrical Permit EL12- 0777ArPoz' 4. Plumbing/Gas Permit s' tp 0 4.hP!oJE1" All above permits are scheduled to expire on 2/12/2013. Design changes and funding have delayed us in getting these permits issued. The permit sets have been resubmitted for review and we are working diligently on getting these permits issued and work underway. These permits are critical to the essential forward progress of building the new sounder station for our customers. If you have any questions regarding this request, please contact me immediately at the number listed below. Sincerely O'Hare Permits Administrator (206) 903-7368 r! l Yk.0 b 2bl vu/W' to 751b U P4WED AMOUNT, o: QTY OF TU 1N1Lp. 1JAN 2.2.2013, PERMIT CENTER od< 40 644d la -(41-63 72z/zog Qx"-o c� Central Puget Sound Regional Transit Authority • Union Station 401 S. Jackson St., Seattle WA 98104 -2826 • 206 - 398 -5000 • 1- 800 - 201 -4900 • www.soundtransit.org =CHAIR Pat McCarthy Pier'c'e County Executive VICE CHAIRS :Julia Patterson. King County- Coun'cilnieniber Aaron Reardon .Snohoniish County Executive' BOARD MEMBERS Claudia Balducci Bellevue Cotrncilmen:ber 'Fred Butler Issaquah Deputy,Counc:1 President Richard Conlin Seattle Councilmember, Dow Constantine Kiirg 'County Executive Dave Earling Edmonds Mayor Dave Enslow Sumner Mayor Paula J. Hammond P.E. ( ' 'Washington State Secretary of .Transportation".:. John Marchione ; .Redmond May° Joe McDermott' King County Councilmeryber Mary Moss a�- 1 akewoodCouncilmember. Larry Phillips :• King County Corincilmeniber- Paul Roberts verett Councilmember Marilyn Strickland .Tacoma Mayor; Peteryon Reichbauer g `County. Councrinreniber .T, k CHIEF. EXECUTIVE OFFICER' om Earl"' 01 -02 -2013 KYM WILLIAMS 401 S JACKSON ST SEATTLE WA 98104 ukwila • Jim .Haggerton,-Mayor .epartment:of Cortimunity Development JackPace; Director RE: Permit Application No. PG12 -160 SOUND TRANSIT SOUNDER STATION 7301 LONGACRES WY TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 08/22/2012, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 02/18/2013. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. PG12 -160 6300 Southcenter Boulevard; Suite: #100 Tukwila, Washington 98188 • Phone 206-431 =3670: Fax 2,06 -431 -3665 lEflitiff CO COP? PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG12 -160 DATE: 08 -22 -12 PROJECT NAME: SOUND TRANSIT SOUNDER STATION SITE ADDRESS: 7301 LONGACRES WY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bui ina- Division y 1 0 1.17— Public Works Fire Prevention n Planning Division Structural n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 08 -23 -12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route gl. Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 09-20-12 Not Approved (attach comments) DATE: Permit Center; Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Punter Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company UNIVERSITY MECH CONTR INC 2063649900 11611 49Th Pl W Mukilteo WA 982754255 Snohomish Corporation UBI No. 578025176 Status Active License No. UNIVMC *343N9 License Type Construction Contractor Effective Date 8/29/1966 Expiration Date 10/3/2014 Suspend Date Specialty 1 General Specialty 2 Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status UNIVEMC009C4 UNIVERSITY MECH CONTR INC Electrical Contractor Hvac /Rfrg Lighting Maintenance 2/24/2000 7/30/2014 Active GRANSML982R3 GRANSTON MECHANICAL LLC Construction Contractor General Unused 12/23/2002 1/8/2009 Expired Business Owner Information Name Role Effective Date Expiration Date BUSH, GERALD D President 03/13/2002 Bond Amount GRANSTON, EDWARD B Secretary 03/13/2002 08965196 PETTERSON, DEAN M Treasurer 03/13/2002 SMITH, DOUG Vice President 03/18/2002 TRAVELERS CAS & SURETY CO KOMMERS, EDWARD D Vice President 03/13/2002 09/13/2004 BALDWIN, TERRY L Vice President 03/13/2002 09/10/2003 GRANSTON, FRANK Treasurer 03/18/2002 12/23/2002 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 FIDELITY Et DEPOSIT CO OF MD 08965196 07/31/2009 Until Cancelled $12,000.0006/04 /2009 6 TRAVELERS CAS & SURETY CO 103335164 07/22/2001 Until Cancelled 07/31/2009 $12,000.0010/03 /2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 31 Phoenix Insurance Company, The DTC0526D8270PHX11 06/01/2011 06/01 /2014 $1,000,000.0005 /03/2013 30 THE PHOENIX INS CO C0526D8270PHX10 10/01/2010 10/01/2011 $1,000,000.0009 /22/2010 29 PHOENIX INS CO C0526D8270PHX09 10/01/2009 10/01/2010 $1,000,000.0009 /22/2009 28 TRAVELERS PROPERTY CAS INS CO DTE0526D8270TIL07 10/01/2007 10/01/2009 $1,000,000.0009 /19/2008 27 TRAVELERS PROPERTY CAS INS CO DTEC0526D8270TIK07 10/01/2007 10/01/2008 $250,000.0009/21 /2007 http s : / /fortress . wa. gov /lni /bbip /Print. aspx 09/23/2013 • Gen Notes.dwg 6/15/2012 1:1 110801 _TK —M0.01 LEGEND i 1'E PERMIT RC-OUIRED • 1 Eleabled 0 Rafting D Gas Ploky City of TukvvIta $UILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittatr and may include additional plan review fees:- , REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2012 City of u iia BUILDIN i ISION FILL' CO 'v Permit No., P( \2_ 1,1D Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By ' Date :. VolV203 City Of Tukwila BUILDING DIVISION GENERAL NOTES 1. THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW THE EXACT DETAILS AND LOCATIONS, NOR ALL OFFSETS IN DUCTWORK AND PIPING. CONTRACTOR SHALL PROVIDE ADDITIONAL FITTINGS, OFFSETS AND EXTENSIONS IN PIPING, DUCTWORK AND RELATED MECHANICAL INSULATION AS REQUIRED TO MEET THE INTENT OF THE DOCUMENTS. CONTRACTOR SHALL INCLUDE IN HIS BID PROVISIONS TO RELOCATE OR SHIFT PIPING AND DUCTWORK WHERE CONFLICTS EXIST WITH STRUCTURE, ARCHITECTURE OR ELECTRICAL. CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OWN COORDINATION BETWEEN ALL OTHER TRADES. DEVELOPMENT OF SHOP DRAWINGS SHALL BE A COLLABORATIVE EFFORT BETWEEN THE GENERAL CONTRACTOR, MECHANICAL CONTRACTOR AND ALL OTHER SUBCONTRACTORS WORKING ON THE PROJECT. SHIFTING OF PIPING, DUCTWORK AND OTHER MECHANICAL ITEMS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TEAM TO MAINTAIN THE INTENT OF THE DOCUMENTS. MAINTAIN MAINTENANCE & SERVICE ACCESS TO ALL MECHANICAL EQUIPMENT. GENERALLY RUN PIPING & DUCTWORK AS HIGH AS POSSIBLE, AVOID MAJOR WALKWAYS & ACCESS ROUTES. 4. SHEET METAL: ALL PRODUCTS SHALL COMPLY W/ SMACNA DUCT CONSTRUCTION STANDARDS, SECOND EDITION. 5. SEAL ALL DUCT WORK AS REQUIRED BY WASHINGTON STATE ENERGY CODE. 6. PROVIDE LEAK TESTING FOR HIGH AND /OR LOW PRESSURE DUCTWORK AS REQUIRED BY WASHINGTON STATE ENERGY CODE. 7. RATING OF ACCESS DOORS AND /OR ACCESS PANELS THROUGH FIRE -RATED WALLS, SHAFTS, CEILINGS, ETC., MUST EQUAL THE MATERIAL PENETRATED. 8. ALL EQUIPMENT SHALL BE LABELED PER PLAN DESIGNATIONS. 9. ALL RECTANGULAR & ROUND DUCTWORK SIZES SHOWN ARE SHEET METAL. PROVIDE TURNING VANES IN ALL RECTANGULAR 90- DEGREE ELBOWS, &• WHERE SHOWN ON ROUND DUCT. 10. PROVIDE NEC CODE MINIMUM WORKING CLEARANCE IN FRONT OF & OVER ANY ELECTRICAL PANEL. OFFSET PIPING & DUCTWORK AS REQUIRED. 11. DUCTWORK SHALL MEET THE INSULATION REQUIREMENTS OF THE WASHINGTON STATE ENERGY CODE. ALL SHEET METAL DUCTWORK SHALL BE INSULATED IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE. 12. ALL PIPING SHALL BE INSULATED IN ACCORDANCE W/ THE WASHINGTON STATE ENERGY CODE, INCLUDING REFRIGERANT PIPING. 13. DIFFUSERS & GRILLES SHALL BE COORDINATED W/ PLACEMENT OF LIGHT FIXTURES. 14. MECHANICAL CONTRACTOR SHALL VERIFY HEIGHT, DEPTH, & LOCATION OF LIGHT FIXTURES TO AVOID ALL CONFLICTS WITH DUCTS, EQUIPMENT & MOUNTING BRACKETS. ALLOW A MINIMUM OF 3" CLEARANCE ABOVE LIGHTING FIXTURES FOR INSTALLATION OF WIRING CONNECTIONS. 15. COORDINATE LOCATIONS OF ALL EQUIPMENT AND APPURTENANCES W/ OTHER TRADES. 16. CONTRACTOR. SHALL PROVIDE COMPLETE OPERATING SYSTEMS. . 17. WHERE FLEXIBLE DUCTWORK IS SHOWN TO CONNECT TO CEILING DIFFUSERS, PROVIDE 6' MAXIMUM OF FLEXIBLE DUCT. USE INSULATED DIFFUSER BOX AT DIFFUSER. SEE DETAIL 2, SHEET' M1.01. 18. PROVIDE VOLUME DAMPERS AT ALL BRANCHES FOR BALANCING. 19. PROVIDE FLEXIBLE CONNECTORS AT SUPPLY AIR & RETURN AIR CONNECTIONS TO EQUIPMENT 20. MECHANICAL SYSTEMS SHALL COMPLY W/ CHAPTER ° 14 OF THE WASHINGTON STATE ENERGY CODE. 21. CONTROLS SHALL ALLOW FOR AIR SYSTEM TEMPERATURE RESET, MINIMUM 5- DEGREE DEAD BAND, OPTIMUM START, AND NIGHT SETBACK 22. PROVIDE O &M MANUALS, OWNER TRAINING, AND RECORD DRAWINGS PER SPEC SECTIONS 20 08 00. BALANCE AIR AND WATER SYSTEMS PER SECTION 23 05 93. COMMISSION SYSTEMS PER SECTIONS 20 08 00. RECEIVED AUG 2 3 2012 TUKVVILA p NLID WORKS RECEIVED AUG 2 2 2012 PERMIT CENTER P612 -Imo No. Date By Chk. App. Revisions Designed By scs Drawn By. TMP Checked By. DMM Approved By. WYL Scale: •IngConsulting Engineers 1601 Flfth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 31308. 06/1 Submitted: Date: T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 Approved: SOUNDTRANSIT Date: • 90% PER \1T SUBvITTAL_ NO SCALE SOU \ 3 TR A \SIT TJ <W L_A STAT O\ Filename: TK -M0.0 I .dwg Contract No.: RTA /CP 0 101 -05 Date: 06/1 5/1 2 T� <W ILA, 'WASH \ GTO\ Drawing No.: MECHAN I CAL LEGEND AND GENERAL NOTES MECHAN 1 CAL LEGEND SYMBOL DESCRIPTION COLD WATER (CW) HOT WATER (HW) WASTE OR SANITARY SEWER (W OR SS) -- - - - - -- VENT (V) FIRE SPRINKLER PIPING F PIPE DOWN I, c I PIPE UP +� BRANCH - SIDE CONNECTION i . CAP END OF PIPE FLOW DIRECTION FLUSH CLEANOUT (FCO) OR SURFACE CLEANOUT (SCO) AS INDICATED o NON- FREEZE WALL BOX HYDRANT (NFBH) / GATE VALVE (GV) CHECK VALVE (CV) TEMPERATURE /PRESSURE RELIEF VALVE (T &PV) STRAINER —CIE UNION -- BALL VALVE (BV) DRAIN VALVE WITH HOSE CONNECTION OR HOSE BIBB 4 AUTOMATIC OR MANUAL AIR VENT (AAV, MAV) 0 PRESSURE GAUGE THERMOMETER REDUCED PRESSURE BACKFLOW PREVENTER RPBP FLOOR DRAIN (FD) o FLOOR & FUNNEL DRAIN (F &FD) • SUPPLY AIR -DUCT UP �E EXHAUST /RETURN AIR - DUCT UP = SUPPLY AIR - DUCT DOWN ilibiEr. EXHAUST /RETURN AIR - DUCT DOWN Mai= ` 12/1_1_,...2 RR 300 CFM AIR TERMINAL SIZE, TYPE & CUBIC FEET PER MINUTE (CFM) CEILING AIR TERMINAL - SQUARE N BACKDRAFT DAMPER (BDD) -II FLEXIBLE CONNECTION (DUCT) OT ROOM TEMPERATURE SENSOR /THERMOSTAT --A. COMBINATION FIRE /SMOKE DAMPER (CFSD) G.C. GENERAL CONTRACTOR M.C. MECHANICAL CONTRACTOR E.C. ELECTRICAL CONTRACTOR WCO WALL CLEAN OUT SCO SURFACE CLEAN OUT FCO FLOOR CLEAN OUT T &P TEMPERATURE AND PRESSURE RELIEF VALVE BFV BUTTERFLY VALVE RD ROOF DRAIN ORD OVERFLOW ROOF DRAIN , POC POINT OF CONNECTION 90% PER \1T SUBvITTAL_ NO SCALE SOU \ 3 TR A \SIT TJ <W L_A STAT O\ Filename: TK -M0.0 I .dwg Contract No.: RTA /CP 0 101 -05 Date: 06/1 5/1 2 T� <W ILA, 'WASH \ GTO\ Drawing No.: MECHAN I CAL LEGEND AND GENERAL NOTES A DUCTLESS SPLIT SYSTEM OUTDOOR UNIT SCHEDULE , UNIT NO SERVICE MFR MFR /MODEL COOLING HEATING SEER POWER CONNECTION OPERATING WEIGHT (LBS) - NOTES TOTAL MBH OA ('F) TOTAL MBH OA (°F) MCA MOP VOLT /PH CU -1 ELECTRICAL ROOM MITSUBISHI PUZ— HA3ONHA2 30 95 19 17 16.1 28 30 208/1 265 - 00 NOTES: 0 DO NOT EXCEED MAXIMUM TUBING LENGTH. 02 M.C. TO PROVIDE POWER WIRING TO INDOOR UNIT PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. DUCTLESS SPLIT SYSTEM INDOOR UNIT SCHEDULE UNIT NO SERVICE MFR MFR / MODEL CFM TOTAL COOLING MBH EAT POWER CONNECTION (2) OPERATING WEIGHT (LBS) FILTER SEER NOTES DB (F) WB (°F) FLA MCA VOLT /PH AC -1 ELECTRICAL ROOM MITSUBISHI PCA— A3OKA4 565 30 80 67 0.54 1 208/1 71 WASHABLE 16.1 0000 NOTES: 0 410a REFRIGERANT O POWER CONNECTION FROM OUTDOOR UNIT O PROVIDE W/ HARD —WIRED WALL — MOUNTED REMOTE CONTROLLER O PROVIDE W/ INTEGRAL CONDENSATE PUMP FAN SCHEDULE UNIT NO MFR MODEL AREA SERVED TYPE PERFORMANCE POWER CONNECTION BACK DRAFT DAMPER SPEED CONTROLLER WEIGHT (POUNDS) NOTES CFM TSP (IN) RPM SON HP /W VOLT /PH EF -1 COOK GN 162 RESTROOM IN LINE 130 0.25 1074 2.0 86 W 120 /1 YES YES 18 00 EF -2 COOK GN 162 JANITOR CEILING 130 0.25 1074 2.0 86 W 120/1 YES YES 18 00 NOTES: 0 SWITCH W/ ROOM LIGHTS 02 PROVIDE W/ FACTORY —WIRED SPEED SWITCH & WHITE ALUMINUM GRILLE GRILLE, REGISTER, DIFFUSER AND LOUVER SCHEDULE SYMBOL AIR TERMINAL EGH EXHAUST GRILLE TITUS MODEL 50 —F FOR INSTALLATION IN HARD CEILING. PAINT DUCT MATTE BLACK BEHIND GRILLE. FINISH SHALL BE #26 WHITE. SEE PLANS FOR SIZES. WTG WALL TRANSFER GRILLE: TITUS MODEL 350 —RL STEEL GRILLE WITH HORIZONTAL BLADES SPACED 3/4" AND 35° DEFLECTION. SEE PLANS FOR SIZES. PAINT DUCT MATTE BLACK BEHIND GRILLE. FINISH SHALL BE #26 WHITE. TURN BLADES UP. SWSG SIDEWALL SUPPLY GRILLE TITUS MODEL 300 -FL DOUBLE DEFLECTION REGISTER WITH 3/4" BLADE SPACING. FINISH SHALL BE #26 WHITE. WPL LOUVER; SEE ARCHITECTURAL PLANS AND SPECIFICATIONS ELECTRIC POINT-OF-USE WATER HEATER SCHEDULE UNIT NO AREA SERVED , LOCATION . MFR MODEL ELECTRICAL TEMP. RISE °F. GPH 0 60° RISE CAPACITY (GALLONS) OPERATING WEIGHT LBS NOTES VOLT /PH KW WH -1 ANCILLARY BUILDING ROOM 104 IN— SINK — ERATOR W -154 120/1 1.5 80' 10.4 4 15 INCLUDE 3' CORD WITH GROUNDED PLUG PLUMBING FIXTURE SCHEDULE FIXTURE NO FIXTURE DESCRIPTION /MFR /MODEL NUMBERS LOCAL PIPING CONNECTION NOTES W V CW HW P-1A WATER CLOSET DURA— WARE, WALL HUNG, COMPACT SIPHON JET: ACORN ENGINEERING 2105— T- 1 -FVB0 —ADA, DUAL FLUSH VALVE: SLOAN "SOLIS" 8111 - 1.6/1.1 -8N' SOLAR POWERED DUAL FLUSH. CARRIER: ZURN, 1203 —N4 —XH OR 1204— N4 —XH, 500 LB MISC: MOUNT FLUSH CONTROLS 44" AFF; MOUNT W/ SEAT AT 17" TO 19" AFF 4" 2" 1" — HANDICAPPED DUAL FLUSH P -2A URINAL DURA -WARE, WALL HUNG, WASHDOWN: ACORN ENGINEERING 2158— T- 1 -FVB0 -ADA, 0.5 GALLON FLUSH VALVE: SLOAN "SOLIS" 8186 -0.5 SOLAR POWERED SENSOR ACTIVATED CARRIER: PROVIDED FOR WALLS UP TO 8" THICK. MISC: MOUNT FLUSH CONTROLS 44" AFF; MOUNT W/ RIM NO MORE THAN 17" AFF 2" 1 -1/2" 3/4" — HANDICAPPED P— 3A LAVATORY °. DURA -WARE, WALL HUNG, 18 "x22 ": ACORN ENGINEERING 1953LC— ADA- 1— DMS- 9- H1— GT —TPT, TAILPIECE /TRAP INCLUDED FAUCET: SLOAN "SOLIS" EAF -275 —ISM, 0.5 GPM SOLAR POWERED WITH INTEGRAL SPOUT TEMPERATURE MIXER. ETF -312A 4 "CC TRIM PLATE SUPPLIES: BRASSCRAFT NO SCR1912AC, OR EQUAL BY McGUIRE OR EASTMAN HANGER: CONCEALED ARM CARRIER ZURN 1231 MISC: PROVIDE POWERS E480 POINT OF USE MIXING VALVE, OR APP'D EQUAL ON HOT WATER PIPING. PROVIDE HOT /COLD WATER SUPPLY AND WASTE PROTECTION — TRAP WRAP BY BROCAR PRODUCTS, INC. OR HANDI —LAV —GUARD BY TRUEBRO, INC. MOUNT LAV W/ RIM AT 34" AFF SO THAT CLEARANCE HEIGHT IS AT LEAST 29" 2" 1 -1 /2" 1 /2" 1/2" HANDICAPPED P -5 SERVICE, SINK FLOOR MOUNT, 36 "x24 ", MOLDED STONE, STAINLESS STEEL DOME STRAINER: FIAT NO MSB -3624 FAUCET: ADJUSTABLE INLETS, VACUUM BREAKER SPOUT, PAIL HOOK WITH WALL SUPPORT, INTEGRAL` STOPS, 3/4" HOSE THREAD OUTLET: CHICAGO FAUCET NO 897 —CP TRAPS & TAILPIECES: PROVIDED WITH UNDERGROUND PIPING SUPPLIES: INTEGRAL TO FAUCET MISCELLANEOUS: PROVIDE FIAT 832 —AA 30" LONG 3/4" 'HOSE AND HOSE BRACKET, AND FIAT 889 —CC STAINLESS STEEL MOP HANGER. SEAL SEAM BETWEEN SERVICE SINK AND WALL WITH FIAT 832 -AA SILICONE SEALANT. PROVIDE STAINLESS STEEL WALL GUARD TO EXTEND UP WALL 2.. SIDES TO APPROX. 42" AFF 1500 2" 3/4" 3/4" FLOOR MOUNTED P -6 ELECTRONIC . TRAP PRIMER ELECTRONIC TRAP PRIMING MANIFOLD, PRECISION PLUMBING PRODUCTS MP- 500 -115V. PROVIDE WITH DISTRIBUTION UNIT & RECESSED MOUNTING BOX W/ STAINLESS STEEL ACCESS DOOR _ 1 /2" _ ELECTRIC HEATER SCHEDULE UNIT NO MFR MODEL LOCATION WATTS SIZE VOLT /PM NOTES EH -1 MARKEL E3055TDWB _ RESTROOM 1500 10 "x12 "x3" 120/1 1 2 EH -2 MARKEL E3055TDWB JANITOR 1500 10 "x12 "x3" 120/1 1 2 EH -3 MARKEL E3055TDWB HALL 1500 10"x12" 3" 120/1 00 EH -4 MARKEL E3055TDWB , STORE ROOM 1500 10 "x1 2 "x3" 120/1 00 NOTES: 0 WALL MOUNTED; PROVIDE W/ MANUFACTURER'S MOUNTING FRAME O INTEGRAL THERMOSTAT W/ "OFF" POSITION, MOUNTED ON UNIT ELECTRIC CABINET HEATER SCHEDULE UNIT NO MFR MODEL AREA SERVED CFM MOTOR COIL kW POWER CONNECTION DISCONNECT NOTES VOLT /PH MCA MOP CH -1 TRANE FFCB020 GUARD 250 1/15 3.0 208/3 12.5 15 BY E.C. 0000 NOTES: 0 BOTTOM RETURN O OUTSIDE AIR DAMPER, AUTO TWO POSITION, BACK OUTSIDE AIR OPENING O FRONT DUCT COLLAR O 2 -STAGE HEAT EXPANS 1 ON TANK SCHEDULE UNIT NO MFR MODEL SERVICE TYPE TANK VOLUME MAX SIZE INCHES NOTES DIAMETER HEIGHT ET -1 ARMSTRONG ST -5 —C WH -1 BLADDER 2.1 10 10 -3/8 002 NOTES: 0 NSF RATED FOR POTABLE WATER O ASME RATED MIXING VALVE SCHEDULE UNIT NO MFR MODEL SERVICE WATER CONNECTIONS NOTES CW INLET HW INLET OUTLET MV -1 LEONARD 370 120° HW 3/4" 3/4" 3/4" WALL MOUNTED CERTIFIED LEAD —FREE REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2012 City of Tukwila BUILDING DIVISION flf9144. I b� 90% P ECEIVED AUG 22 2012 PERMIT CENTER -RV T SUBV TTAL Designed By scs No. Date By Chk. App. Revisions Drawn By TMP Checked By: DMM Approved By WYL EEO Consulting. Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Scale: NO SCALE Filename: TK— M0.02.dwg Contract -No.: RTA /CP 0101 -05 Submitted: Date: Approved: Date: Date: 06/15/12 SOUND TRA \S T TL, <W LA, T KWILA STATFON WAS I\ GTO\ MECHAN 1 CAL SCHEDULES • Drawing No.: TK -MO.02 Sheet No.: Rev.: 287 J Z 3/4" RELIEF < a VALVE SET 0 65# -\‘ o rz MAV 4 NOTES: 1. ALL MATERIALS IN CONTACT WITH WATER TO BE COPPER, BRASS, BRONZE, EPDM, OR STAINLESS STEEL. SERVICE SINK t0 z -J S m GLOBE VALVE 144 w in 00 1 m aO LO .-3" WATER HAMMER ARRESTOR 1- 2" HEADER BLIND FLANGE 1 r PRESSURE REDUCING VALVE; 33 GPM 0 80 PSI INLET & 60 PSI OUTLET LUG -TYPE BUTTERFLY VALVE,= 1 I Fr GALVANIZED STEEL SLEEVE 1" ABOVE FF WITH LINK SEAL 2' -0" L__ -f RPBP TO SITE BOX. . , WALL HYDRANTS y-AIR GAP FITTING - PIPE DISCHARGE FULL SIZE TO DRAIN rFINISHED FLOOR SUPPORT PIPES 5' FROM BLDG � - FINAL CONNECTION BY M.C. DOMEST 1 C WATER HEADER DUCT TAPE SCALE: NONE CUT 1 -1/2" RIGID INSULATION TO FIT. ATTACH WITH DUCT TAPE CONCRETE BY G.C. FLOOR DRAIN BODY DURING CONCRETE POUR (STEP #1) INSTALL STRAINER, STRAINER HEAD, & FLASHING COLLAR (SET FINAL ELEV) 2" BUILDING SERVICE REMOVE AND STORE STRAINER, STRAINER HEAD AND FLASHING COLLAR PIPE SIZE AS NOTED ON PLANS CW SUPPLY" T ACCESS ON WALL COORDINATE LOCATION W/ G.C. STRAINER HEAD STRAINER FINISHED L GROUT BY M.C. �-- BALL VALVE —H TRAP PRIMER I VALVE DISTRIBUTION UNIT FLOOR DRAIN BODY CONCRETE BY G.C. PIPE SIZE AS NOTED ON PLANS FLASHING COLLAR AFTER CONCRETE HARDENS (STEP #2) NOTE: COMPLETE INSTALLATION OF FLOOR DRAIN AND SETTING OF FINAL ELEVATION WILL NOT BE ALLOWED DURING INITIAL CONCRETE POUR FLOOR DRAIN I NSTALLAT 1 ON SCALE: NONE TO FLOOR DRAINS HW TO FIXTURES - SIZE AS SHOWN ON PLAN 4 -120'F IN -LINE FLOW CONTROL NOTE; WATER HEATERS AND EXPANSION TANKS SHALL HAVE SEISMIC SUPPORTS ATTACHED TO STRUCTURE DESIGNED BY OTHERS (TYPICAL) 0 MV -1 THERMOMETER (30' -180') ASME RATED COMBINATION TEMPERATURE & PRESSURE RELIEF VALVE INSTANT -FLOW WATER HEATER WH -1 CORD AND GROUNDED PLUG POWER GFCI RECEPTACLE FINISHED FLOOR -\ 1 Its cw — SIZE AS SHOWN ON PLAN EXPANSION TANK ET -1 PIPE FULL SIZE TO MOP SINK L__, SERVICE SINK I I N STAN T- FLOW WATER HEATER 1 NSTALLAT 1 ON SCALE: NONE ADJUSTABLE WALL CLAMP \\ \` INTERIOR FACE \\ OF WALL \ \' \\ \\' NFBH - NON- FREEZE WALL BOX HYDRANT KEY - OPERATED VALVE VACUUM BREAKER HOSE CONNECTION LOCKING COVER KEY EXTERIOR FACE OF WALL NON- FREEZE WALL BOX HYDRANT (NFBH) SCALE: NONE WEATHERPROOF LOUVER PER PLANS DIMENSIONS PIPE SIZE (OUTSIDE DIAMETER) BASE DIAMETER UNIT HEIGHT 1 /4" to 3" 7 -3/4" 4" 4" to 6" 10 -3/4" 5" 15' -0" MIN FROM ANY FRESH AIR INTAKE DEK -TITE (OR APP'D EQUAL PIPING FLASHING (SIZE AS SHOWN BELOW) PIPE DIAMETER 1 12" MIN UNIT HEIGHT BASE DIAMETER METAL. ROOF PIPE FLASH I NG SCALE: NONE BIRDSCREEN LOPE.. .Ark 2"9 C, OUTSIDE WALL INSULATION PER SPECIFICATIONS COORDINATE HYDRANT INSTALLATION WITH ARCHITECTURAL PLANS, SEE SHEETS TK -A8.40 FOR KIOSK DETAILS 18" FACE OF KIOSK WALL HYDRANT KEY 6" SCHEDULE 40 SLEEVE FINISHED GRADE /FLOOR — 15" 1 HEAT TRACE & INSULATE WATER PIPING FROM 18" BELOW GRADE TO BACK OF 1FREEZELESS WALL HYDRANT. ELECTRICAL TO BE SOURCED FROM 120V CIRCUITS SERVING KIOSK 1173/4" TYPE K COPPER PROVIDE MINIMUM 24" COVER REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2012 City of Tukwila BUILDING DIVISION PLENUM AS SHOWN ON PLANS SELF- ADHERING RUBBERIZED ASPHALT FLASHING 6" PROVIDE 1/2" SPACE BETWEEN BOTTOM OF BIRDSCREEN AND BACK EDGE OF LOUVER TO ALLOW DRAINAGE I)G I U WEATHERPROOF LOUVER 1 NSTALLAT 1 ON SCALE: NONE PIPE 1" TYPE K COPPER PIPE TYPE K COPPER SUPPLY MAIN; SIZE AS SHOWN ON PLAN K 1 OSK, FREEZELESS WALL HYDRANT SCALE: NONE REFRIGERANT PIPING SIZE AS RECOMMENDED BY EQUIPMENT MANUFACTURER PIPE INSULATION PER SECTION (BOTH LINES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS) "UNICUSHION" VIBRATION ELIMINATING PAD ALL SUPPORTS UNISTRUT - LAG TO 2x6's 0 24" O.C. PIPE CLAMP (TYP.) NOTES: PROVIDE PIPING SUPPORT AS SHOWN AT ALLOWABLE SPACING AS NOTED IN SPECIFICATIONS FOR PIPE HANGERS. COVER ENTIRE LENGTH OF EXPOSED PIPING ON EXTERIOR WALL W/ 24 GA. GALV. SHEET METAL FLASHING. (2) COATS PRIMER, (1) COAT EPDXY PAINT REFRIGERANT PIPING ON' "ECEIVED AU6 22 2012 PERMIT CENTER EXTERIOR WALL SCALE NONE No. Date By Chk. App. Revisions Designed By scs Drawn By IMP Checked By DMM Approved By WYL Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463. SOUNDTRANSIT Scale: NO SCALE Filename: TK- M0.03.dwg Contract No.: RTA /CP 0101 -05 Submitted: Date: Approved: Date: Date: 06/15/12 SOU \3 TRA \S.T TU 90% PERK <WILA STAT 0\ TU <W LA, WASH \GTO\ MECHAN I CAL DETAILS IT SJBV Drawing No.: TTAL TK -MO.03 Sheet No.: Rev.: 288 • • • 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT O (SIM.)\ 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT i (SIM.) EXTEND PIPING 5' BEYOND FOUNDATION (TYP.) SEE CIVIL PLANS FOR CONTINUATION (TYP.) 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT O (SIM.) TRANSIT SHELTERS SCALE: I /16" = I' -0" TK —M1.00 IJ 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT O PARATRANSIT SHELTER SCALE: I /16" = I' -0" 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT O TK —M1.00 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2012 City of Tukwila BUILDING DIVISION STRUCTURAL COLUMN PLAN NOTES 0 DOWNSPOUTS — SEE DETAIL 4 /TK —M1.00 & ARCHITECTURAL DETAILS 8/TK —A8.15 AND 11/TK—A8.15 UP TO GUTTER; SEE ,.� ARCHITECTURAL DETAIL 11/TK—A8.15 3" SCHEDULE 80 STAINLESS STEEL PIPE i STRAP f CLEANOUT SEAL STAINLESS STEEL SLEEVE CONNECT TO DOWNSPOUT CONNECTOR AND DOWNSPOUT TIGHTLINE; SEE CIVIL PLAN TK —DR.02 & ARCH DETAIL 8/A8.15 DOWNSPOUT CONNECTION SCALE: I /16" = I ' -0" TK —M1.11 TK= .14 TK -M1.24 %' Br `II'1 II II\ 1 1 1 1 000000000000 0000000 0 00000000000000 000 000000000000000 000006000000000000000000 00000000000000000000 0 0000000 Oa 0 0 00 00 000 0 000 MECHANICAL SITE PLAN SCALE: 1" = 40' Designed By. scs Drawn By TMP Checked By DMM irrEfirel Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622- 5822 Fax (206) 622 -8130 Approved By WYL No. Date By Chk. App. Revisions 06/1 T R E S W E S T TK —M1.00 Scale: In 40' -0" P6 tfoximp- 160 40 20 0 40 ED) 80 SCALE IN FEET 907 P SOU \3 TRA \ST TUKWLA STAT TU < :W LA, WAS \ G TO \I ENGINEERS ,INC. Filename: TK —M 100.dwg Submitted: 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Contract No.: RTA /CP 0101 -05 IRV 0\ TK —M1.21 RECEIVED AUG 2 22012 PERMIT CENTER IT SJBV I TTAL Drawing No.: TK -M 1.00 MECHAN I CAL SITE PLAN Sheet No.: Rev.: Date: Approved: Date: Date: 06/15/12 E • • UNISTRUT (2) CH -1. \- UNISTRUT (2) FLEXIBLE CONNECTION (TYP.) CONNECT TO STRUCTURE; SEE STRUCTURAL PLANS FOR STRUCTURE TYPE (TYP.) VIBRATION ISOLATOR (TYP.) BOTTOM RETURN OPENING CEILING - MOUNTED FAN OR. CAB 1 NET HEATER 1 NSTALLAT 1 ON SCALE: NONE 410 OUTSIDE AIR CONNECTION 0 32/12 PL INDOOR AIR HANDLER OUTSIDE AIR CONNECTION TO LOUVER SCALE: NONE REVIEWED FOR CODE CO CE APPROVED SEP1021 City of Tukwila BUILDING DIVISION 014/12 WP U -1 ›- REFRIGERANT PIPING AC -1 0 X12/6 32/12 WPL 8/8 WTG BOTH SIDES W/ SHEETMETAL SLEEVE) .CFSD 'r'-aVaNIT 4 CONIENSATE DRAIN PIPING 2/12 WPL /8 WTG BOTH SIDES v/ SHEETMETAL SLEEVE) 12/6 8/6 ED BDD 3 EF -1 - DD :: 130 CFM 8/6 EF -2 130 8 17-- FILTER RACK E W/ 1" FILTERS 0 EH -3 H RETURN ON BTM OF UNIT 0 32/12 WPL -4-- 16/8 SOUNDLINED ..._' 8/6 )Lif �J r'�' 1 r - -1 6/ 10 .f - 8/4 CFM '6 EGH 0 CFM 6/6 EGH 30 CFM 16/8 SOUNDLINED I 1 /8 SWSGI 2 0 CFM 16/8 TG BOTH IDES IN/ SHEETMETAL SLEEVE (TYP.) ANC 1 LLARY BU 1 LD 1 N G— M ECH AN 1 CAL PLAN SCALE: 1 /4" = 1 I - 0 " PLAN NOTES O LOUVER IS TO FIT INTO FRAME; SEE SHEET TK- A10.11FOR EXACT SIZE AND LOCATION. SEE DETAIL 7 /TK -M0.03 FOR PLENUM REQUIREMENTS ® SEE SHEET TK -A4.11 FOR EXACT LOCATION 0 MOUNT EQUIPMENT SO AS TO PROVIDE MAXIMUM HEAD HEIGHT AVAILABLE 04 7 -DAY PROGRAMMABLE CONDENSATE PIPING DN TO SERVICE SINK - CEILING ACCESS PANEL; SEE SHEET 5/A2.11 f)&tizumw bo TK—M 1 .00 4 SCALE IN FEET 8 RECEIVED AUG 22 2012, PERMIT CENTER 90% P_R V T SUB TTAL Designed By sc$ Drawn By TMP No. Date By Chk. App. Revisions Checked By DMM Approved By. WYL Mil Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622--5822 Fax (206) 622 -8130 TRES WEST ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Filename: TK —M 1 I .dwg Submitted: Date: Approved: Date: Contract No.: RTA /CP 0101 -05 Date: 06/15/I2 SOJ \3 TRANSIT TJ /<WILA• STATION TU <WI LA, WASH GTON ANCILLARY ABU I LD I NG - MECHAN I CAL Drawing No.: TK -M 1.0.I Sheet No.: 290 Rev.: • E E H 2" AREA DR IN 3 "0 STAIN SS STEEL DOWNSP T UP TO GUTTER (REF. ' - A5.21) & DOWN TO STO (REF. DK- DR.02) O .2 M0.03 P- LECTRONIC TRAP PRIMER; k CCESS FROM JANITOR RO' /2 "CW 3 /4 "HW P -5 o4" 2 -WAY SCO 16' -2" 1"CAP FOR FUTURE '3 /4 "CW AREA DRAIN TO STORM; , SEE TK -DR.02 & TK- UC.02` T &P: DRAIN FULL SIZE TO SERVICE SINK P -5 1 -1 /2 "NON - POTABLE WATER TO SITE; FOR CONTINUATION SEE SHEETS TK -M1.11 THROUGH TK -M1.14 FIRE SPRIN SEE SHEET FOR FIRE SPRI PLAN & DETAILS AP RIMER VALVE 2 "V 4 "V UP TO 4 "VTR 2 "V M0.03 FWH- 2" AREA DRAIN 1' -8" 3 "0 ST DOWNSP (REF. STORM (RE • POC 1 5' -0" TO BLDG EDGE (TYP.) 0 r(6 STAINLESS STEEL DOWNSPOUT UP TO GUTTER (REF. TK- A5.21) & DOWN TO STORM (REF. DK- DR.02) . POC FOR CON TINUA11O 1 SEE TK -UC.02 2"STORM UP TO DRAIN L� 2 "DOMESTIC CW SERVICE POC; . 4" 2 -WAY SCO • 5' -0" TO BLDG EDGE (TYP.) g POC, FIRE PROTECTION SUPPLY, SEE SHEET TK -M1.03 FOR FIRE SPRINKLER PLAN & DETAILS AREA DRAIN TO STORM; SEE TK -DR.02 & TK -UC.02 P-6 ELECTRONIC TRAP PRIMER; ACCESS FROM STORAGE ROOM INLESS S sUT UP TK 5.21) ANC I LLAkY BUILDING - PLUMB•I NG PLAN . POC F 4 "SS L_ f FIRE SERVICE 0 3 "0 STAINLESS STEEL DOWNSPOUT UP TO GUTTER (REF. TK- A5.21) & DOWN TO STORM (REF. DK- DR.02) SCALE: 1/4" = 1' -0" TKM1.0 0 l 4 ". 2 -WAY SCO 5' -0" r-- - - - 1 1 1 1 1 f4 4 PLAN NOTES O 1 -1/2 "RPBP FOR NON- POTABLE CW TO SITE ® FIRE SPRINKLER STANDPIPE DRAIN, SEE SHEET TK -M1.03 FOR FIRE SPRINKLER PLAN AND DETAILS 2 "-\ DOWNSPOUTS - SEE DETAIL 4 /TK -M1.00 & ARCHITECTURAL DETAILS 8/1X -A8.15 & 11 /TK -8.15 ROOF 4'- - -- 1 - -- CEILING 2FU. 2 "FD 2 "-i 2 "Th 2 "- 2 "-•*,1 2FU HALL 2 "FD 2FU 2 "FD 2FU STO 2 "FD POC S\ 1 -1/2 "NON- POTABLE WATER UP 4 "S�. U 2 "S 4 "SS UP UP WCO 2 "STORM UP TO AREA DRAIN di 4 "- 2FU 2" 2" 2FU P- 2A Co 2-� 1FU RR P -3A^ CO% 2" 2" 3FU 2 "FCO P =5 WCO I I\ FINISHED FLOOR 2" 3 4" „ / 4 "- 2�p 12 4 "2 ® �j 4 "/ REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2012 City of Tukwila BUILDING DIVISION 1 -1/2 "NON- POTABLE CW WATER TO SITE, FOR CONTINUATION SEE SHEET TK -M ANC I LLARY BU I LD 1 NG - FOUN TAT ION PLAN SCALE: 1/4" = 1' -0" SANITARY SEWER AND VENT RISER DIAGRAM SCALE: DIAGRAMMATIC 2 TK—M1.0 0 SCALE IN FEET i 90% P TK —M1.02 RECEIVED AUG 222012 PERMIT CENTER -RvIT SUB V TTAL Designed By. scs Drawn By. TMP No. Date By Chk. App. Revisions Checked. By DMM Approved By. WYL IMIN Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Scale: 1/4" = I 1 -0" Filename: TK —M 1.02.dwg Contract No.: RTA /CP 0101 -05 Submitted: Date: Approved: Date: Date: 06/15/12 SOU\ TRANSIT TUKWILA STAT O\ TJ <W LA; WASH \ GTO \ ANCILLARY BUILDING - PLUMBING Drawing No.: TK -M 1.02 Sheet No.: 29I Rev.: • • FOR CONTINUATION SEE TK —UC.02 2 1 F POC 5' -0" TO BLDG EDGE FIRE PROTECT •N SUPPLY MAIN FIRE SPRINKLER HEADER STANDPIPE DRAIN 1 IRE DEPARTMENT ONNECTION 42" ABOVEw INISHED GRADE 0 FIRE SPRINKLER HEADER 1- 7,..J: T ,00 4,-- - _ , 3� M1.03�. ANCILLARY BUILDING FIRE SPRINKLING PLAN 6 "0 STANDPIPE DRAIN FOR FIRE SPRINKLER SYSTEM BRACKET 2 "VENT PIPE BRACKET WATER MOTOR GONG OUTSIDE, WALL - - STRAP TO WALL. COORDINATE WITH FIRE SPRINKLER CONTRACTOR 4" WASTE 30" FLOOR PROVIDE P —TRAP WITH TRAP PRIMER FIRE SP_R I NKLER HEADER STANDPIPE DRAIN DETAIL SCALE: NONE SCALE: 1/4" = I' -0" TK -M1.00 FIRE DEPARTMENT CONNECTION F r F CHECK VALVE FIRE SPRINKLER HEADER STANDPIPE DRAIN rJ REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2012 City of Tukwila BUILDING DIVISION STRAINER f F TO BUILDING i,e: RETARD CHAMBER WITH PRESSURE SWITCH MAIN DRAIN AND FLOW jTEST VALVE - WET PIPE ALARM CHECK VALVE AND PRESSURE GAUGES - -4' F "W L J FIRE PROTECTION SUPPLY MAIN 5--- -F TO FIRE ALARM PANEL OS & Y VALVE WITH TAMPER SWITCH DOUBLE DETECTOR CHECK VALVE ASSEMBLY PROVIDE STEEL PIPE SLEEVE (TYPICAL) EXTEND 1 "ABOVE FINISHED FLOOR. INSTALL WITH LINK SEALS NOTES 1. PROVIDE PIPE SUPPORTS AND. ANCHORS AS REQUIRED TO SUPPORT ENTIRE VALVE ASSEMBLES. 2. THIS DIAGRAM IS PRESENTED AS AID TO CONTRACTOR. IT DOES NOT RELIEVE CONTRACTOR FROM MEETING ALL REQUIREMENTS OF NFPA 13 AND LOCAL AUTHORITIES. FIRE SPRINKLER HEADER DIAGRAM SCALE: NONE PLAN NOTES 0 COORDINATE PENETRATION SIZE AND LOCATION WITH STRUCTURAL ENGINEER FIRE SPR I NKL I NG GENERAL NOTES 1. DESIGN, FURNISH AND INSTALL A COMPLETE "WET PIPE" AUTOMATIC SPRINKLING SYSTEM FOR THE ANCILLARY BUILDING INCLUDING AREAS ABOVE AND BELOW CEILINGS, ATTIC SPACES, INTERSTITIAL SPACES. THE AUTOMATIC SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13 . (IBC 903.31 STANDARDS), IBC, IFC AND ALL LOCAL CODES AS A MINIMUM STANDARD. ADDITIONAL REQUIREMENTS ARE NOTED IN THE SPECIFICATIONS OR IN THESE DRAWINGS. 2. PROVIDE COVERAGE FOR THE ENTIRE ANCILLARY BUILDING INCLUDING AREAS ABOVE AND BELOW CEILINGS, ATTIC SPACES, MEZZANINES, INTERSTITIAL SPACES, OVERHANGS AND MECHANICAL /ELECTRICAL ROOMS. THE ASSUMPTION OF FIRE ALARM DEVICES OR SYSTEMS BEING INSTALLED DOES NOT RELIEVE THE FIRE SPRINKLING CONTRACTOR OF PROVIDING COVERAGE IN ALL AREAS. 3. THE INTENT OF THIS DRAWING IS TO SHOW THE ROUTING OF THE LARGER FIRE SPRINKLER MAIN IN CRI11CAL AREAS. ALL PIPING SHALL BE CONCEALED EXCEPT FOR WHERE NOTED ON THIS DRAWING. ANY DEVIATIONS IN THE FIRE MAIN LAYOUT SHOWN HERE SHALL BE APPROVED BY THE ARCHITECT DURING SUBMITTAL PROCESS BEFORE INSTALLATION AND SHALL BE AT NO ADDI110NAL COST TO THE OWNER. NO EXPOSED. PIPING WILL BE ALLOWED IF, IN THE BUILDING STRUCTURE, THE ARCHITECT HAS PROVIDED SHAFTS, FURRED AREAS, OR CONCEALED SPACES WHERE PIPING COULD BE HIDDEN FROM VIEW. DO NOT RUN PIPING OVER ELECTRICAL PANELS OR SWITCHGEAR: EXCEPT WHERE LOCATED ABOVE THE STRUCTURAL CEILING. 4. FIRE SPRINKLER MAIN NOT SHOWN SHALL BE LAID OUT PER FIRE SPRINKLER COVERAGE REQUIREMENTS. SEE ARCHITECTURAL DRAWINGS FOR AREAS NOT SHOWN OR FOR MULTIPLE FLOORS THAT REQUIRE FIRE SPRINKLING COVERAGE. 5.. THE FIRE SPRINKLER CONTRACTOR SHALL COORDINATE THE LOCATION OF THE PIPING AND HEADS TO AVOID INTERFERENCES WITH LIGHT FIXTURES, HEATING /COOLING EQUIPMENT, DUCTWORK AND ANY ARCHITECTURAL FEATURES SUCH AS EXPOSED SLOPE ROOF STRUCTURES, SKYLIGHTS, STAIRWAYS, ETC. IN CATWALK AREAS, PIPING SHALL BE RUN AS HIGH AS POSSIBLE TO ALLOW THE MAXIMUM HEADROOM OVER THE MECHANICAL EQUIPMENT AND AISLE SPACES. MAXIMUM CLEARANCE SHALL BE MAINTAINED FOR SERVICE ACCESS AND MAINTENANCE FOR ALL EQUIPMENT. FAILURE TO COORDINATE SHALL BE JUSTIFICATION TO REQUIRE THE FIRE SPRINKLER CONTRACTOR, AT HIS OWN EXPENSE, TO MOVE AND REDO HIS WORK. 6. IT SHALL BE THE FIRE SPRINKLER CONTRACTOR'S FULL RESPONSIBILITY TO INSTALL A COMPLETE WORKING SYSTEM MEETING ALL CODES. 7. COORDINATE ALL SPRINKLER HEAD LOCATIONS WITH LIGHTING, MECHANICAL, AND ALL OTHER CEILING APPURTENANCES. SEE TK— A2.11, TK— M1.01, & TK —E2.11 SCALE IN FEET 90% P v RECEIVED AUG 22 2012 PERMIT CENTER IT SUB VI I TT AL No. Date By Chk. App. Revisions Designed By scs Drawn By. TMP Checked By DMM Approved By WYL ERR Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206). 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463. SOUNDTRANSIT Scale: /4' = 1 1-0" Filename: TK —M 1 .03.dwg Contract No.: RTA /CP 0101-05 Submitted: Date: Approved: Date: Date: 06/15/12 SOU \3 TRA \SIT T, ,<WILA STAT O\ TU <WILA, WASH \ GTO ANCILLARY BUILDING - FIRE SPRINKLING Drawing No.: TK M 1.03 Sheet No.: 292 Rev.: A • H 1 1 "NON— POTABLE CW 4 1 PLAN NOTES 0 1" NON - POTABLE CW UP TO KIOSK NON— FREEZE WALL BOX HYDRANT; SEE DETAIL 4 /TK —M0.03 PARTIAL BELOW GRADE PLAN 1 - MECHAN I CAL SCALE: 1/8" = V-0" 1 "NON— POTABLE CW REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2012 City of Tukwila BUILDING DIVISION 1 TK—M1.0 0 1 L J KEY PLAN 0 8 16 SCALE IN FEET 90% PER V RECEIVED AUG 22 2012 PERMIT CENTER IT SUB VIITTAL Designed By scs Drawn By TMP No. Date By Chk. App. Revisions Checked By DNN Approved By WYL Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 Submitted: Date: T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE -(253) 472 3300 FAX (253) 472 3463 Approved: Tie SOUNDTRANSIT Date: Filename: TK —M I.1 I .dwg Contract No.: RTA /CP 0101 -05 Date: 06/15/12 SOU \3 TRA \SIT TJKWILA STAT T, <W LA, WASH \GTO\ PARTIAL BELOW GRADE PLAN I MECHANICAL 0\ Drawing No.:. TK -M I.I Sheet No.: 293 • Rev.: SEE DWG TK -M1.11 1 I I 1 1 I 1 1 1 1 1 \--1 NON—POTABLE CW \-1-1/2 NON—POTABLE CW Iw w I(/). 1 1 1 1 1 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2012 City of Tukwila BUILDING DIVISION 1 1 0 I— 1 0 1 w w PARTIAL BELOW GRADE PLAN 2 SCALE. :1 /8" = 1' -0" MECHANICAL 1 "NON— POTABLE CW � 1 TK —M1.00 111 —1 /2 "NON — POTABLE CW PLAN NOTES 0 in NON— POTABLE CW UP TO KIOSK NON — FREEZE WALL BOX HYDRANT; SEE DETAIL 4 /TK —M0.03 1)G144.- l(pc) 1 1 1 1 1 1 1 1 1 1 KEY PLAN 0 8 16 No. Date By App. Revisions Designed By SCS Drawn By: TMP Checked By DMM Approved By WYL 06/1 EIZE14. Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE` (253) 472 3300 .. FAX (253) 472 3463 L' SOUNDTRANSIT Scale: 1/8" Filename: TK —M I.12.dwg Contract No.: RTA /CP 0101 -05 Submitted: Date: Approved: Date: Date: 06/15/12 SCALE IN FEET 9070 PER V SOU \D TRA \SIT TJKWILA STAT O\ TJ�WI�A, WASH \GTO\ PARTIAL BELOW GRADE PLAN 2 - MECHANICAL RECEIVED AUG 222012 PERMIT CENTER IT SUBV TTAL Drawing No.: TK -M I. 12 Sheet No.: 294 Rev.: 0 01 W wl (n 1 i r FOR CONTINU; SEE SHEET TI TI ON -M1.02 —1/2"NON—POTABLE CW - —1/2"NON—POTABLE CW / 2 "NON - POTABLE CW —1/2 NON—POTABLE CW J 1 1 1 1 1 1 -1 /2 "NON— POTABLE CW IN CASING - SEE TK —UC.05 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 1 0 2012 City of Tukwila BUILDING DIVISION 1 1 1 NI I1 j-1 C� 1 �1 0IW 1 -1 /2 "NON— POTABLE CW 1 PART I 'AL BELOW GRADE PLAN 3 SCALE: 1/8" = 1' -0" MECHANICAL rTh TK--M1.00 —1/2"NON—POTABLE CW PLAN NOTES 0 1" NON— POTABLE CW UP TO KIOSK NON— FREEZE WALL BOX HYDRANT; SEE DETAIL 4 /TK —M0.03 PG100147- 1 0 to Iw W rn KEY PLAN 0 8 16 SCALE IN FEET 90% P -RV Designed By SCS Drawn By TMP Checked By. DMM No. Date By Chk. App. Revisions Approved By WYL DEMConsulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH. 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 T SOUNDTRANSIT Scale: 811 = I' -0" Filename: TK M I.13.dwg Contract No RTA /CP 0.101 -05 Submitted: Date: Approved: Date :. Date: 06/1 5/1 2 SO \D TRANSIT TUKWILA STAT TU <W LA, WAS I \ GTON PARTIAL BELOW GRADE PLAN 3 - MECHANICAL 0\ RECEIVED AUG 22 2012 PERMIT CENTER T SUBV I TTAL Drawing No.: TK -MI.I3 Sheet No.: 295 Rev.: • C • 3” SCHEDULE 80 STA NLESS STEEL DOWNSPOUT UP; CONTINUED ON SHEET TK —M1.14 NFBH; SEE TI< -A2.12 FOR EXACT LOCATION (SIMILAR) 6 MO.3 1 1 1 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT; ROUTE UNDER SLAB ABOVE 1 1 1NON— POTABLE CW 1 1 1 1 i 3" SCHEDULE 80 STAINLESS BICYCLE CAGESTEEL DOWNSPOUT; ROUTE UNDER SLAB ABOVE 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT .UP; CONTINUED ON SHEET TK —M1.14 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT® 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT; ROUTE UNDER SLAB ABOVE; CIVIL TO CONNECT TO TRENCH DRAIN PIPING, REF. TK —DR.05 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2012 City of Tukwila BUILDING DIVISION O `) O 0 O 0 O 0 O 0 O 0 O 0 O 0 O 0 POTABLE CW PLAN NOTES 0 1" NON - POTABLE CW UP TO KIOSK NON— FREEZE WALL BOX HYDRANT; SEE DETAIL 4 /TK —M0.03 PART I AL BELOW GRADE PLAN 4 MECHAN I CAL SCALE: :1 /8" = 1' -0" (Thi rK— M1.00 KEY PLAN sN 4 16 SCALE IN FEET No. Date App. Revisions Designed By scs Drawn By. TMP Checked By DMM Scale: Approved By WYL Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 $OUNDTRANSIT Filename: TK —M I.14.dwg Contract No.: RTA /CP 0101 -05 =RVIT SUBV TTAL Drawing No.: TK -M 114 SOJ \D TRA \S T T „KWILA STAT O\ T <WI LA, WAS \ GTO\ Submitted: Date: Approved: Date: Date: PARTIAL BELOW GRADE PLAN 4 - MECHANICAL Sheet No.: Rev.: 06/15/12 A • • • I N N I' 1 0 Ic JLU W i 1 1 S--2) 1 1 1 PLAN NOTES KIOSK NON- FREEZE WALL BOX HYDRANT; SEE DETAIL 4/TK —M0.03 PARTIAL PLATFORM PLAN 1 MECHAN I CAL E COMPLIANCE D FOR COD APPRE SEP I 0 2012 BUILDING h+ of Tukwila DING DIVISION p64.1.1-01610 1 SCALE: 1/8" = 1' -0" TKM1.0 0 KEY PLAN 0 8 16 SCALE IN FEET 90% PER V 4 ,ECEIVED AUG 222012 PERMIT CENTER T SUB V ITTAL No. Date By Chk. App. Revisions Designed By SCS Drawn By TMP Checked By DNN Approved By WYL Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 TRES WEST ENGINEERS ,INC 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Scale: /8" = II_OII Filename: TK —M I.21.dwg Contract No.: RTA /CP 0101 -05 Submitted: Date: Approved: Date: Date: 06/15/12 SOU\ 3 TPA \S IT TUKWILA STAT O TU <W LA, WASH N GTO PARTIAL PLATFORM PLAN I - MECHANICAL Drawing No.: TK -M 1.21 Sheet No.: 297 Rev.: 1 1 • ■ i ■ I�I�I�I�I�I 0 3" SCHEDULE 80. STAIN ESS STEEL, 0 • -.1 o�— ®1.1■I1.1® .1=1=1 ■ 3" SCHEDULE 80 STAIN ESS STEEL 1 • " •POUT, STAINLESS STEEL 3" SC STAIN EDULE 80 SS STEEL ;OUT�1 1 1 1 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 10 2012 City of Tukwila BUILDING DIVISION .w.w I- Iw._ .e CI —I�I�I 11 ■ 11 i 111 111 IN ®ICI WI `=C= 1111010".1111 a 3" CHEDULE 80 STA NLESS STEEL DOWNSPOUT 0 . PARTIAL PLATFORM PLAN 2 MECHAN I CAL SCALE: 1/8" = 1' -0" 3"' SCHEDULE 80 STA NLESS STEEL DOWNSPOUT PLAN NOTES 3" SCHEDULE 80 TAINLESS STEEL • „ •7.�e ■mow KIOSK NON— FREEZE WALL BOX HYDRANT; SEE DETAIL " 4 /TK —M0.03 0 DOWNSPOUTS — SEE DETAIL 4 /TK— M1.00, & ARCHITECTURAL DETAILS 8/TK —A8.15 AND 11/TK— A8.15. CONNECT TO STORM DRAINAGE, REF. TK —DR.02 THRU TK —DR.06 1 1 i 1 1 1 3" SCHEDULE 80 STA NLESS STEEL DOWNSPOUT P apo 1° w w KEY PLAN 0 8 16 SCALE IN FEET No. Date By Chk. App. Revisions Approved By WYL 06/1 MrgConsulting Engineers 1601 Flfth . Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 TRES WEST ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Scale: Contract No.: RTA /CP 0101 -05 Submitted: Date: Approved: Date: Date: 06/15/12 S0 „ \3 TRA \SIT TU K TU K W LA, WAS 90% PERV WI LA STAT 0\ \GTO\ PARTIAL PLATFORM PLAN 2 - MECHANICAL w fl ECEIVEID. AUG 222012 PERMIT CENT& . IT SUBV Drawing No.: TTAL Sheet No.: N N • uJ W ■ A., 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT O 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT 1 1 1 W W 1 1 1 1 1 I I REVIEWED FOR CODE COMPLIANCE APPROVED SEP 1 0 2012 BUILDING of Tukwila DIVISION NI PART 1 AL PLATFORM PLAN 3 - MECHAN 1 CAL SCALE: 1/8" = 1' -0„ EMI 0 L uU P I 3" SCHEDULE 80 • • STA NLESS STEEL DOWNSPOUT TK—M1.0 0 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT P6101 iv) PLAN NOTES O1 KIOSK NON— FREEZE WALL BOX HYDRANT; SEE DETAIL 4 /TK -M0.03 0 DOWNSPOUTS — SEE DETAIL 4 /TK —M1.00 & ARCHITECTURAL DETAILS 8/TK —A8.15 AND 11/TK— A8.15. CONNECT TO STORM DRAINAGE, REF. TK —DR.02 THRU TK —DR.06 KEY PLAN 0 8 16 Designed By scs Drawn By TMP No. Date By Chk. App. Revisions Checked By DMM Approved By WYL eirEIN Consulting. Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S W E S T ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSIT Scale: 1 /8" = 11-0" Filename: TK -M I.23.dwg Contract No.: RTA /CP 0I0I -05 Submitted: Date: Approved: Date: Date: 06/15/12 SOU SCALE IN FEET 90% PER v IT RECEIVED AUG 2 2 2012 PERMIT CENTER S B V TTA L TRA \S T TUKWILA STATIO\ TUKWILA, WAS \ G TO \ PARTIAL PLATFORM PLAN 3 — MECHANICAL Drawing No.: TK -M 1.23 Sheet No.: Rev.: 299 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT;. CONNECT TO GUTTER & SEE SHEET TK —M1.14 FOR CONTINUATION 3" SCHEDULE 80 STAINLESS STEEL DOWNSPOUT; CONNECT TO GUTTER & SEE SHEET TK —M1.14 FOR CONTINUATION - 3" SCHEDULE 80 —STAI SATE -EL- DOWNSPOUT 3 "0 STAINLESS STEEL DOWNSPOUT UP TO, GUTTER (TK —A2.13 & TK— A7.13). DAYLIGHT TO —GRAD �- 3 "0 STAINLESS STEEL DOWNSPOUT UP TO GUTTER (TK —A2.13 & TK— A7.13) & DOWN TO STORM (TK— DR.05) 3" SCHEDULE 8 STANLESS—S DOWNSPOUT SEP 10 2012 4 TA NLESS STEEL OWNSPOUT O 3 SCHEDULE 80 STAINLESS STEEL PART 1 AL PLATFORM PLAN 4 MECHAN 1 CAL SCALE: 1/8" = 1. -0„ TK—M1.00 PLAN NOTES O KIOSK NON--FREEZE WALL BOX HYDRANT; SEE DETAIL 4/TX—M0.03 O DOWNSPOUTS — SEE DETAIL 4 /TK —M1.00 & ARCHITECTURAL DETAILS 8/TK -A8.15 AND 11/TK—A8.15. CONNECT TO STORM DRAINAGE, REF. TK —DR.02 THRU TK -DR.06 0 DAYLIGHT TO TRENCH DRAIN; REF. TK —DR.05 RECEIVED AUG 2 2 2012 PERMIT CENTER 0-'R9il 1-110.9i1 • IA,- 160 KEY PLAN 4 0 8 SCALE IN FEET 16 90% PER VIIT S „B V Designed By. scs Drawn By. TMP Checked By DMM Scale: Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101 (206) 622 -5822 Fax (206) 622 -8130 T R E S WEST 1/8 11 ENGINEERS ,INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409 -7315 TELEPHONE (253) 472 3300 FAX (253) 472 3463 SOUNDTRANSR Filename: TK —M 1 .24.dwg Contract No.: RTA /CP 0101 -05 SOU \ D TR A \SIT TL K WI LA STATIC' T„ KWI LA, WASH \ GTO\ TTAL Drawing No.: TK -M I .24 Approved By WYL No. Date By Chk. App. Revisions Submitted: Date: 06/1 Approved: Date: Date: PARTIAL PLATFORM PLAN 4 - MECHAN I CAL Sheet No.: 300 Rev.:. 06/15/12