HomeMy WebLinkAboutPermit PG12-164 - ROTO ROOTERROTO ROOTER
10655 TUKWILA
INTERNATIONAL BL
PG12 -164
City o*Tukwila
1
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
PLUMBING /GAS PIPING PERMIT
Parcel No.: 0423049169 Permit Number: PG12 -164
Address: 10655 TUKWILA INTERNATIONAL BL TUKW Issue Date: 09/14/2012
Permit Expires On: 03/13/2013
Project Name: ROTO ROUTER
Owner:
Name: DESIMONE TRUST 106SSPHS
Address: C/O BNY MELLON NA , 1201 3RD AVE STE 5010 98101
Contact Person:
Name: BUD KLOSTERMAN
Address: 8706 S 222 ST , KENT WA 98031
Email: BUD @STATEMECH.NET
Contractor:
Name: STATE MECHANICAL COMPANY
Address: 600 INDUSTRY DR 8 , TUKWILA WA 98188
Contractor License No: STATEMC 141 C7
Phone: 206 575 -7527
Phone: (206)575 -7527
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
INSTALL ONE NEW TOILET AND LAVATORY ON MODIFIED ROUGH -INS
Value of Plumbing /Gas Piping: $2,800.00 Uniform Plumbing Code Edition: 2009
Fees Collected: $137.81 International Fuel Gas Code Edition: 2009
Electrical Service Provided by:
Permit Center Authorized Signature:
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions
on the back of this • ermit.
Signature:
Print Name:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -4/10
PG12 -164 Printed: 09 -14 -2012
PERMIT CONDITIONS
Permit No. PG12 -164
1: ** *PLUMBING AND GAS PIPING * **
•
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded m concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
doc: UPC -4/10
PG12 -164 Printed: 09 -14 -2012
CITY OF TUKJ
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
• .
Plumbing/Gas Permit No. l II:" k.0-1
Project No.
Date Application Accepted:1.��
Date Application Expires:
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
t King Co Assessor's Tax No.: 0 LI UL1 / Ci q
Site Address: 3(2 55 r vfL44(1-4
LNr U L V 0 Suite Number: Floor:
Tenant Name: 1(2.C_)1-0 �UV 1 (,2 New Tenant: ®.,...Yes ❑..No
PROPERTY OWNER
Company Name: sT. are (i 0/9) ( c- L
Name: 17 16 c.OSTE2 0'lA m
Name: ceS [�4.ytcM2
+ltuST
Contr Reg No. ST(}TC- /1/1 C.1 'll C'} Exp Date: y/(/3
Address:
x.)5(
Phonsio ce -57Q 5 "75Z 7 FaxZd� - ,575 -7 5
City:
State:
Zip:
CONTACT PERSON - person receiving all project
communication
Company Name: sT. are (i 0/9) ( c- L
Name: 17 16 c.OSTE2 0'lA m
City: ,/_ ,0
,..r_ State: Li A Zip: 9803'
Address: % ad c s ZiLq i d sr
J sr
Contr Reg No. ST(}TC- /1/1 C.1 'll C'} Exp Date: y/(/3
State R Ziipp
City: K-r� -�Tr
x.)5(
Phonsio ce -57Q 5 "75Z 7 FaxZd� - ,575 -7 5
29'
Email: bo0_, Sfotkvv\42.Ck•Vt '
PLUMBING CONTRACTOR INFORMATION
Company Name: sT. are (i 0/9) ( c- L
Address: 7
G - "L 2 2- Al° ST
City: ,/_ ,0
,..r_ State: Li A Zip: 9803'
Phon4ioco- 575_? 521 Fax:ZUCo -5 75-71' Z-ci
Contr Reg No. ST(}TC- /1/1 C.1 'll C'} Exp Date: y/(/3
Tukwila Business License No.:
Valuation of Project (contractor's bid price): $ 2, D C()
Scope of Work (please provide detailed information): O PA c.) p [ F(C- l7
i nl Sr/�U., N L-1 D AYG JJGc&) T2 L 3 L..4u (A-7-c3 2Y
0LC--1 H - l NSj
Building Use (per Int'l Building Code):
Occupancy (per Int'I Building Code):
Utility Purveyor: Water: Sewer:
H:WpphcattonslForns- Applications On Luse\2011 Apphcations'Plumbmg Perms Application Revised 8- 9- 11.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
t
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backtlow
protections (1 -5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
t
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
t
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1 -5
inlets /outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 Intemational Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWUTI ZED AGE T: ..
Signature:
Date: Vz VI
Print Name: Ask r _ . S� _:..V it Day Telephone: '2(T Je' 7S Y- 7S Z7
//"" N 3
Mailing Address: S OLtt 3 �,22 S� )<- tC_(ij� �!'T �'j�
City State Zip
nWpplications \Forms - Applications On Line \2011 Applications Plumbing Permit Application Revised 8- 9- 11.dov:
Revised: August 2011
bh
Page 2 of 2
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.TukwilaWA.gov
RECEIPT
Parcel No.: 0423049169 Permit Number: PG 12 -164
Address: 10655 TUKWILA INTERNATIONAL BL TUKW Status: PENDING
Suite No: Applied Date: 08/28/2012
Applicant: ROTO ROUTER Issue Date:
Receipt No.: R12 -02473
Payment Amount: $137.81
Initials: JEM Payment Date: 08/28/2012 10:29 AM
User ID: 1165 Balance: $0.00
Payee: STATE MECHANICAL CO.
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 2024 137.81
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
PLUMBING - NONRES
000.345.830 27.56
000.322.103.00.00 110.25
Total: $137.81
doc: Receiot -06 Printed: 08 -28 -2012
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO`
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 - •x•:,.(206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
Type of Inspection:
Address:
is t0S3 -1-
Date Called:
Instructions:
Date Wanted:.
ca.n1..
Requester:
Phone No: _
Approved per applicable codes.
ElCorrections required prior to approval.
COMMENTS:'
j2in;4-CQisic,04 -
tarispecZ L'4^^a.1 / ��iG�1/t��•{
n RE)hSPECTION FEE REQUIRED. Prior to
6a1d at 6300 Southcenter Blvd.. Suite 100.
INSPECTION RECORD
�..� Retain a copy with permit P6/2 -16,c�';
INSPECTION NO. PERMIT NO..
CITY OF.TUKWILA BUILDING DIVISION .•
6300 Southcenter Blvd., #100, Tukwila: WA 98188 - (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
!2
Project:
/.)3T U /? 60-7C-/? .
Type of Inspection: -
/6) /c./.7 " /
Address:
/0(7SS -r- z.
Date Called:
Special Instructions:
Date Wanted:. _
T —• /A, /e7
/Cm'.
Requester:
Phone No:
-1O6 —9 i q C)5 7 ",
." . .
J'Approved per applicable codes.
Corrections required prior to -approval.
COMMENTS:
Irfspector:
4w _ 114)
PECTION FEE REQUIRp . Prior to xt inspection. fee must be
t 6300 Southcenter Blvd.. Suite 1011 to schedule reinspection:
1,4
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT,NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206)431 -367
Permit Inspection Request Line (206) 431 -2451
Pro ct:
/(4-Ira 40
�
Type of Inspection:
Address: _
--r
Date Called:
Special Instructions:
Date Wanted:.
,A.m..
Requester:
Phone N,p:
®Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
t
Inspectter:
Date:
r-
REINSPECTION FEE REQUIRED. Prior to next inspection; fee:must:be:
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. .
2 "VTRI
2 "VEN, -1
3 "w
WC
TIE INTO
EX WASTE
ROTO ROUTER RISER DIAGRAMS
*CLEAN OUTS PER CODE
I "Cw
WC
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 0 7 2012
City of Tukwila
BUILDING DIVISION
LAV
TIE INTO EX HOT
AND COLD WATER
RECEIVED
CITY OF TUKW ILA
AUG 2 8 2012
PERMIT CENTER
PCiIr I(n�l
COORD COPIIS
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG12 -164 DATE: 08/28/12
PROJECT NAME: ROTO ROUTER
SITE ADDRESS: 10655 TUKWILA INTERNATIONAL BL
X Original Plan Submittal
Response to Correction Letter #_
Response to Incomplete Letter #
Revision # after Permit Issued
DEP RTMENTS: ` 1
L-
B I Ing Division
Public
vvidcgi- ‘}
Fire Prevention
Structural
Planning Division
Permit Coordinator n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete n
Complete
DUE DATE: 08/30/12
Not Applicable ❑
Comments:
Permit,Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
Structural Review Required ❑
No further Review Required ❑
REVIEWER'S INITFALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 09/27/12
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center; Use. Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑
Staff Initials:
Contractors or Tradespeople Peter Friendly Page
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
■ County
Business Type
Parent Company
STATE MECHANICAL COMPANY
2065757527
8706 S 222Nd St
Kent
WA
98031
King
Corporation
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
600611697
Active
STATEMC141C7
Construction Contractor
2/27/1986
9/1/2013
Plumbing
Unused
Other Associated Licenses
License
Name
Type
Specialty 1
Specialty 2
Effective
Date
Expiration
Date
Status
DESIGM'110NQDESIGN
MECHANICAL
Construction
Contractor
Boiler /Steam
Fit /Proc Piping
Plumbing
8/18/1989
8/17/1993
Archived
RXHCO "121NARXH
COMPANY
Construction
Contractor
Plumbing
g
Boiler /Steam
Fit /Proc Piping
8/1/1988
7/27/1999
Archived
GERRICI163B3
GERRIK
COMPANY INC
Construction
Contractor
General
Unused
1/23/1984
1/9/1991
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
PLATZ, GREG D
Cancel Date
01/01/1980
Amount
DEWITT, RALPH E
23
01/01/1980
GL166026
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
3
TRAVELERS CAS &
SURETY CO
200686359
07/27/2001
Until Cancelled
$6,000.00
08/14/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
23
Colony National
Ins Co
GL166026
06/02/2012
06/02/2013
$1,000,000.0006
/01/2012
22
Colony Ins Co
GL1650262
06/02/2011
06/02/2012
$2,000,000.0006
/02/2011
21
COLONY INS CO
GL1650262
06/02/2010
06/02/2011
$1,000,000.0009
/16/2010
20
COLONY INS CO
GL1650261
06/02/2008
06/02/2011
$1,000,000.0005
/06/2010
19
FIRST MERCURY
INS CO
FMFL001801
06/02/2006
06/02/2008
$1,000,000.0005
/09/2007
18
NORTH
AMERICAN
CAPACITY
PNG100046600
06/02/2006
06/02/2007
$1,000,000.0005
/25/2006
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
09/14/2012
o-a
EX. WAREHOUSE
STOkAGE
+10'03" AFF
11
11
EX. WAREHOUSE STORAGE
+1010" AFF
111
1 1 III 11 1 1 1 1 1 REMOVE EXISTING STAI
1 / 1 Il►'I BE REPLACED)
EX. WARE
!.STORAGE
+9'0" AFF
U)
USE
(TO
EXISTIN MEZZANINE STO4G NORTH: DEMO
SCALE: 1/8" = i' -0"
949 S.F.
n REVISIONS
No changes shall be made to the scope
I of work without prior approval of
Tukwila Building Division_
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
DEMO NOTES:
1. REMOVE EXISTING FLOORING, SEAL EXPOSED CONCRETE (SEE FINISHES)
2. REMOVE EXISTING WINDOWS FOR REPLACEMENT
3. REMOVE DAMAGED OR STAINED CEILING TILES
4. REMOVE ARCHWAY TO WAREHOUSE
5. REMOVE EXISTING EXTERIOR DOOR AND "VESTIBULE"
6. REMOVE OLD HVAC UNITS, AND HORIZONTAL MULLIONS FOR
NEW GLAZING
�\ I IN WAREHOUSE, FILL IN ALL HOLES IN EXTERIOR WALLS
8. REPAIR LOUVERS TO OPERATE
9. REMOVE EXISTING STAIR TO MEZZ (T0155 RE- BUILT)
10. REMOVE ANY UN -USED TELEPHONE OR CASELING
REMOVE EXISTING WINDOWS FOR
NEW WINDOWS, TYPIC
REMOVE EXISTING EXTERIOR DOOR
AND EXTERIOR WALLS AND COVER
TO DOOR.
REMOVE EXISTING WINDOWS FOR
NEW WINDOWS, TYPICAL
INCLUDING NON STRUCTURAL
HORIZONTAL MULLIONS.
11
1
11
1
1
/ EX.
OFFICE
EX. OPEN
OFFICE
EX.
OFFICE
EX.
OFFICE
EX. OPEN
OFFICE
REMOVE EXISTING WINDOWS FOR
NEW WINDOWS, TYPICA
SEPARATE PERMIT
REQUIRED FOR:
itediadod
pectricd
th Gas Piling
City of Tukwila
'WILDING DIVISION,
1
2,D
? LO7 61;
REMOVE E)ISTING
ARCHED OPENING
�,�-- REMOVE E ISTING
DOORS 1
REMOVE EXISTING
STAIRS
REMOVE EXISTING
RESTROOMS? AND WALLS,
DOORS, ETC'.
1
EX.
WAREHOUSE.
i
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 0 7 2012
DL
City of u ila
BUILDING DI ISION
EX1ST1NC FIRST FLOOR 8U1LlN NOT1-1: DEMO
SCALE: 1/8" = 1' -0"
FILE COPY
Permit No.
Plan review approval is subject to errors and omissions,
A 3 oval of construction documents does not authorize
t c v Dfation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledged:
By
Date. 4/(
city Of ta
BUILDING DIVISION
RECEIVED
CITY OF TLIKVV1LA
AUG 2 8 2012
PERMIT CENTER
C: \Documents and Settings\All Users\Documents \CAD\201211207 DESIMONE RotoRouter\RotoRooter cd's 06- 05- 12\T- 1 -.dwg, OFFICE AND WARE
SUBMIT FOR PERtilT
N
1
4
7
gX
N0cg)
=r
try
Q�
z
O
m q ao
to`Q
r- v/0)
a)
m
s
r]Ir
r1z
E 0
C:4
o 1-1
s
ail °
C.4
o�
TI -1
OUSE ORTH demo (2), 6/14/2012 2:36:,
2 BULB LIT BAR
FULL WID-IT
MIRROR TO
BACKSPLASH
z
/NEUJ CONSTRUCTION NOTES:
L PROVIDE WINDOIU GOVERNS THROUGHOUT ( 1" LEVELERS)
Z. INSTALL NEW CEILING, TILES TO REPLACE DAMAGED AND STAINED ONES.
3. NEW HYAG IN OFFICES ONLY, INCLUDING OPEN OFFICE.
4. INSTALL NEW OFFICE WALLS IN BACK OPEN OFFICE.
5. PUT ALL LIGHTS IN GOOD UJORICINCz ORDER
6, PROVIDE NEW COUNTER (NO PLUMING) NEXT TO BATHROOM
1, REMOVE OLD NVAC UNITS AND PATCH (NEW GLAZING).
NEW STAIRWAY
WITH HANDRAILS
EACH SID
EX. WAREHOUSE STORAGE
+10'10" AFF
NEW STAIRWAY
WITH HANDRAILS
EACH SID
NEW HANDRAIL AT
STEP IN FLOOR
EX. WAREHOUSE
STORAGE
+10103" AFF
111
/1
11
EX. WAREN
STORAGE
+9'0" AFF
1I'
EX. SOLID WALL
GUARDRAIL (+42 ")
3R61" : 21"
2T611 ": 22"
SE
EX. SOLID WALL
GUARDRAIL ( +42 ")
EXI5TINC MEZZANINE STORAGE NORTH: NEW UIORIC
SCALE: 1/8" - 1' -0"
949 SF
0
LSGE PAINT
GRAB BAR
24'
PLASTIC LAMINATE
WAINSCOAT-- ?
FLUSH HANDLE
ON OPEN SIDE
18"
�igi'ERIOR
INSULATED HOT 4 COLD
5CALE :I /2" = 1' -0"
g LV41 1 ON
11141...L. SC4WULE±
A. INTERIOR- 3 5/8" X 25 GA. STEEL STUD AT 24" O.C. TO EXISTING CEILING (110" VERIFY), WITH
5/8" GYP BD. EACH SIDE WITH SOUND BATT INSULATION, PAINTED (EE)
B. INTERIOR RESTROOM- 3 5/8" X 20 GA STEEL STUD AT 24" O.C. TO NEW GYP BD CEILING (8'
AFF), 5/8" WATERPROOF GYP BD EACH SIDE, SOUND BATT INSULATION, PAINTED (SGE)
C. INTERIOR PLUMBING, 8" TRACK WITH STAGGERED 3, 5/8" STEEL STUD X 20 GA AT 24" O.C., 5/8"
WATERPROOF GYP BD EACH SIDE, SOUND INSULATE
DOOR SCHEDULE:
E1 -E4 INTERIOR EXISTING 21-6"X61-8" WOOD DOOR AND WOOD JAMB,
E6 LATCHSET OR LOCKSET, WALL STOP (REMOVE E4)
E5 EXTERIOR EXISTING 3'X6' -8" S.C. WOOD DOOR AND WOOD JAMB,
LOCKSET
E1 EXTERIOR EXISTING 3'X6' -8" H. METAL DOOR AND H. METAL JAMB,
LOCKSET (ADD LEVER HANDLE, INSIDE TURNS FREE TO EXIT).
ES EXTERIOR EXISTING 12'X14' OVERHEAD DOOR.
1 NEW 3'- 0'X1' -0" ALUMINUM STOREFRONT DOOR WITH 1"
INSULATED SAFTEY GLAZING, CYLINDER LOCK WITH INTERIOR
THUMB TURN,1 " DIAMETER PUSH/PULL, CLOSER, THRESHOLD
MAX. 1/2", INTERIOR STOPS, WEAHTERSTRIP, AND BOTTOM SWEEP
(U =0.60)
2 NEUJ 3'- 0'X6' -8" S.C. WOOD DOR, WOOD JAMB, 1 1/2 PAIR BUTTS,
LOCKSET (LEVER HANDLE), CLOSER, THRESHOLD MAX. 1/2",
WALL STOP, WEATHERSTRIP
3. NEW 3' -0" X 6' -8" S.C. WOOD DOOR AND WOOD JAMB, 1 1/2 PAIR
BUTTS (HINGE CLOSER), PRIVACY LOCK (LEVER HANDLE), WALL
STOP, SILENCERS
4 -6 NEW 3' -0" X 6' -8" 5.0 WOOD DOOR WITH WOOD JAMB, 1 1/2 PAIR
BUTTS, LOCKSET (LEVER HANDLE), WALL STOP AND SILENCERS.
VJINOUJ 5C1-4EULE:
A REMOVE EXISTING, ADD NEW FIXED 5' -10" (4' -10 ")X 4' -2"
(VERIFY) VINYL FRAMED WINDOWS WITH 1" INSULATED
GLAZING WITH 1/2" AIR SPACE, LOW e COATING (U :0.55,
SHGC :0.45)
B REMOVE EXISTING, ADD NEW PAIR FIXED 5'- 0 "X4' -2"
(VERIFY), VINYL FRAMED WINDOWS WITH I" INSULATED
GLAZING WITH 1/2" AIR SPACE, LOW e COATING (U =0.45,
SHGC =0.45)
C REMOVE EXISTNG, RAISE SILL TO 18" AFF (+6 "), ADD NEW
THERMALLY BROKEN ALUMINUM STOREFRONT SYSTEM TO
UPPER HEAD (1' AFF), WIN I" INSULATED GLAZING WITH
1/2" AIR SPACE, LOW e COATING (U =0.55, SHGC =0.45)
NEW ROOM FINISH:
NEW RESTROOM (OTHER SEE NOTES)
FLOOR: NEW SHEET VINYL WITH WELDED SEAMS
BASE: NEUJ 6" COVED SHEET VINYL
WALLS: PAINTED GYP BD (SCE)
WAINSCOT 4' PLASTIC LAMINATE
CEILING: NEW PAINTED GY BD (SCE)
BAR
COVED SHEET VINYL BASE
INTERIOR ELEVATION
SCALE :1 /2" : 1' -0"
SIDEUTAL
ARE FLU
EXISTING
ELECTRICAL
RESTROOM NOTES:
1 ALL ACCESSORIES TO BE MOUNTED AT +40"
TO OPERATING PORTION
2. INSULATE THE HOT, WASTE AND COLD
WATER UNDER SINKS
3. TOILET FLUSH VALVE ON THE WIDE SIDE OF
ROOM
4. SHEET VINYL FLOORING WITH SEAM
SEALER AND COVED'6" SHEET VINYL BASE,
EXISTING FIRST FLOOR BUILDING NOT1-t: NEUJ WORK
SCALE: 1/8" - 1' -0"
OFFICE AREA: 1,350 a 1/100 :14 OCCUPANT LOAD
SINGLE EXIT WITH TRAVEL DISTANCE UNDER 15' TRAVEL DISTANCE
TENANT HAS LESS THAN 15 EMPLOYEES 50 A SINGLE ADA COMPLYING RESTROOM
IS ALLOWED.
OFFICE TO BE HEATED AND COOLED, WAREHOUSE t N HEATED
?�I
(-TTY OF TUMM A
Aut 2 8 2012
?ERMIT CENTER
O)
03
ao oci
tr
0
md
Q
Z3�-
O
mw 1:13
(0
,.400)
c0
O
TI -2
C: \Documents and Settings\AII Users■Documents \CAD\2012 \1207 DESIMONE RotoRouter \RotoRooter cd's 06- 05- 121T- 1 -.dwg, OFFICE AND WARE 0 E O-T* n, 6/ -/2012 2:37:
i
i
1
SUBMIT FOR PERMIT I
N
1
1
O)
03
ao oci
tr
0
md
Q
Z3�-
O
mw 1:13
(0
,.400)
c0
O
TI -2
C: \Documents and Settings\AII Users■Documents \CAD\2012 \1207 DESIMONE RotoRouter \RotoRooter cd's 06- 05- 121T- 1 -.dwg, OFFICE AND WARE 0 E O-T* n, 6/ -/2012 2:37: