HomeMy WebLinkAboutPermit PG12-189 - CITY OF TUKWILA - POOLCITY OF TUKWILA POOL 4414 S 144 ST PG12 -189 City o•E•Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov PLUMBING /GAS PIPING PERMIT Parcel No.: 1523049106 Address: 4414 S 144 ST TUKW Project Name: CITY OF TUKWILA - POOL Permit Number: PG12 -189 Issue Date: 11/13/2012 Permit Expires On: 05/12/2013 Owner: Name: TUKWILA SCHOOL DISTRICT Address: 4640 144TH ST , SEATTLE WA 98168 Contact Person: Name: DAVE ROBINAUGH Address: 5005 THIRD AV S , SEATTLE WA 98134 Email: DAVERO @MCKINSTRY.COM Contractor: Name: MCKINSTRY CO LLC Address: PO BOX 24567 , SEATTLE WA 98124 Contractor License No: MCKINCL942DW Phone: 206 - 832 -8352 Phone: 206 762 -3311 Expiration Date: 03/16/2014 DESCRIPTION OF WORK: REPLACE WATER CLOSETS, FLUSHOMETER VALVES, LAVATORIES, SHOWER TOWERS AND THERMOSTATIC MIXING VALVES. REPLACE DOMESTIC HOT WATER TANK AND GAS REGULATOR. PROVIDE NEW GAS REGULATOR FOR BOILER AND INSTALL REGULATOR VENT TO EXTERIOR. Value of Plumbing /Gas Piping: $91,000.00 Uniform Plumbing Code Edition: 2009 Fees Collected: $777.00 International Fuel Gas Code Edition: 2009 Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied whether specified herein or not. Date: 11,Eit ed this permit and know the same to be true and correct. All provisions of law and ordinances The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th �rformance of w. • . I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions on the back of t p�rmit. Signature: Print Name: Ax),--A'zro/612-4'f Date: g / "DL/ ?pi Z This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. rinr.• IIPC -4110 Pr12 -1A9 Printari• 11- 1'1 -2n17 PERMIT CONDITIONS Permit No. PG 12 -189 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. (Inn* 11PC -4 /1(1 P(117 -1RSi Printpri• 11 -13 -7017 CITY OF TUK A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. i Y �9q Project No. Date Application Accepted: 10-(0-(2--, Date Application Expires: Z-(— ([)' 13 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: 4414 South 144th City of Tukwila PROPERTY OWNER Name: Dave Robinaugh Address: Name: City of Tukwila City: Seattle State: WA Address: 4414 South 144th Phone: (206) 832 -8352 Fax: City: Tukwila State: WA Zip: 98168 CONTACT PERSON - person receiving all project communication Name: Dave Robinaugh Address: Address: 5005 3rd Ave S City: Seattle State: WA Zip: 98134 Phone: (206) 832 -8352 Fax: Email: davero @mckinstry.com Phone: King Co Assessor's Tax No.: 1523049106 Suite Number: - Floor: New Tenant: ❑ Yes m ..No PLUMBING CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 90,000 Scope of Work (please provide detailed information): Replace water closets, flushometers, lavatories, shower towers, and thermostatic mixing valves. Replace domestic hot water tank and gas regulator. Provide new gas regulator for boiler and install regulator vent to exterior. 1(000 9,45 Building Use (per Int'I Building Code). Occupancy (per Int'I Building Code): Utility Purveyor: Water: District 125 Sewer- Valley View H:\Applications\Forms- Applications On Line12011 Applications\Plumbing Permit Application Revised 8 -9 -1 I.docx Revised: August 2011 bh Page 1 of 2 • Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks 99 Rain water system — per dram (Inside budding) !' Grease interceptor for commercial kitchen ( >750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 2B Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) 2 Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Water closet 99 Urinal !' Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment 2B Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller 2 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet 4' Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets 2 Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, Indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1 -5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices vi'.. 1 PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: ER OR AUTHORIZED GENT: Date: 10/10/2012 Print Name: Dave Robinaugh Day Telephone: (206) 832 -8352 Mailing Address: 5005 3rd Ave S H:Wpplications\Fom¢- Applications On Line12011 Applications'Plumbing Permit Application Revised 8- 9.11.docx Revised: August 2011 bh Seattle WA 98134 City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1523049106 Address: 4414 S 144 ST TUKW Suite No: Applicant: CITY OF TUKWILA - POOL RECEIPT Permit Number: PG12 -189 Status: APPROVED Applied Date: 10/10/2012 Issue Date: Receipt No.: R12 -03088 Payment Amount: $621.60 Initials: JEM Payment Date: 11/13/2012 09:16 AM User ID: 1165 Balance: $0.00 Payee: PARKS ACCT NO. 11263001.1000.107 TRANSACTION LIST: Type Method Descriptio Amount Payment Other Authorization No. ACCOUNT ITEM LIST: Description 621.60 Account Code Current Pmts GAS - NONRES PLUMBING - NONRES 000.322.103.00.00 96.60 000.322.103.00.00 525.00 Total: $621.60 rinn• Re int -nR Printcu1• 11- 11 -7f117 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 1523049106 Permit Number: PG12 -189 Address: 4414 S 144 ST TUKW Status: PENDING Suite No: Applied Date: 10/10/2012 Applicant: CITY OF TUKWILA - POOL Issue Date: Receipt No.: R12 -02827 Payment Amount: $155.40 Initials: WER Payment Date: 10/10/2012 02:45 PM User ID: 1655 Balance: $621.60 Payee: ANDREW GRAY TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 02848P ACCOUNT ITEM LIST: Description 155.40 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 155.40 Total: $155.40 doc: Receiot -06 Printed: 10 -10 -2012 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 PC42-9 Project - • (iIit� v1 iuhee✓,lA Type of Inspection: rinlAL..- Address: Ly,y s //4/ sr Date Called: _ Special Instructions: Date Wanted:. v2 — 2-6-/ 5 rn. p.M7 Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 2.."`A -1 ( /€9- 3vrp /e,0 �,:; #, iq/ nspect 41•c -, C f Date ` ?- 2 , /3 n R INSPECTION FEE REQUIR D. Prior to next inspection, fee must be pa d at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. 'i12 - I gcj CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 it.. (206) 431 -3670 Permit Inspection'Request Line (206) 431 -2451 Project: 0 rTgl O1 7t1kluILA Type of Inspection: L Ptui4,t6 --G #S 6 1 17 <w'1,Ji Jt-5 Aic l- ,"i 1 Address: L -ILI(4 1NLi S-1 Date Called: ` O'1 �,0 t \e J 1‘ 41�. Special Instructions: Date Wanted:. a.m. Requester: Phone No: , oC.- 30-4r4 -12 ❑ Approved per applicable codes. Corrections required prior to approval. S COMMENTS: A 6 1 17 <w'1,Ji Jt-5 Aic l- ,"i 1 eeryvv 00/\.‘t NI Ii C. L& 1APDtdrl+9 I ` O'1 �,0 t \e J 1‘ 41�. iii‘d.54A (1,('f , t 4 J n„ C tel NS ? ?CTION FEE REQUIRE. Prior to p /id ( 6300 Southcenter Blvd.. Suite 100. Date: 2 -zL-- i nett inspection. fee must be ll to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: � 0 i op 4 [ 1 i,l rlw►1 r1 Typenof Inspection: ,idl,cj k -- `.% Address: 4_I ill 4 5 / i-I L/ s1i- Date Called: 600N Special Instructions: Date : Wante 1 2. (l–, OZ.— m, :m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: `J, 4 . (1) Poo l 0 ✓rr.&J ?t-'$.5td' ,-� 600N -, tbr: 41 / 't 0LAJrAl /RNSPETION FE EQUIRED /Prior to next inspection, fee must be paid at 6300 Southcen N Blvd., Suite 100. Call to schedule reinspection. °1? /17//7 t (p INSPECTION RECORD Retain a copy with permit INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING - DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 r, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 0 1 VA (D 11ltLL&) L A Type of Inspection: - `01tLH-r.hJ - 114v+l'!'').. Address: ' VIA -kIL( S tLi y S-i Date Called: _ Special Instructions: _ - - (l (...UL I (.0 t Date Wanted: I1)2.7 a. m. Requester: Phone No: ,Ztl ( -73D Approved per applicable codes. Corrections required prior to approval. COMMENTS: - Inspect��o�rr: T( - n I INSPECTION FEE REQUI ED. Prior to next inspection .fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to echedule_reinspection. 1 -1 /2 BF -PASS UPSTREAM -- 150LATION VALVE (NORMALLY CLOSED) ----- _ -__ -� CONNECT TO BAS GAS METER BY PSE BADGER PULE STRAINER TURBO SERIES METERS COUPUNG ADAPTOR POOL FILL METER NOT TO SCALE IEECHANIC4L ROOM 4700 CFH 0 2 P51 Tr (50 IF) 1 -1/2 (10 LF) 2 (40 IF) IPRV -1 U1 p (ARV -21 J DOMESTIC WATER HEATER 500 4TH BOILER 4200 HEM L FROM BACKROW PREVENTER KEY NOTES 0 REFERENCE 4/45.0 FOR CAS PRV INSTAUADON 1ETAL GAS PIPING DIAGRAM NOT TO SCALE HVAC SYSTEM MAKE UP WATER ASSEMBLY NOTES: 1. BOSIS OF DESIGN: WESSEL5 2. REFERENCE MUTING WATER APING DIAGRAM 4462 FOR PIPE SIZES. 3. REFERENCE 4/45.2 & 5/445.2 FOR CONNECTION DETAILS. PRESSURE GAUGE 0 -100 P51 P/T PORT ISOLATION VALVE SERVICE ISOLA ION VALVE 00.6110N VALVE SADDLE (N001146LY OPEN) (NORMALLY OPEN) PIPE OFF TOP OF MAKE -UP WATER LANE SDATION VALVE z- 43 EXPANSION TANK DETAIL NOT TO SCALE CHARGING VALVE EXPANSION TANK rum GAS PIPING, REFERENCE GAP PIPING DVGRMI FOR PIPE SIZES SHUTOFF COCK OR BALL VALVE WITHIN 6' -0' OF EQUIPMENT " DIRT LEG DRAIN PPE FROM 80TT041 OF FILTER TARN 81111 VALVE FOR FLOW CONTROL TO FILTER TANK DRAIN PIPE FOR FILTER TANN OVER FLOW 6' STEEL PIPE BASKET FILTER BCD: HAY5ARD 6" SB PVC SIUPLE0 STRAINER R0 EPDM. OFFSET BASKET FILTER FROM END CAP TO ALLOW ACCESS FOR MAINTENANCE CONCRETE SUB J GAS REGULATOR VENT PIPED TO EXTERIOR (VENTS TO BE PIPED SEPARATELY) PIPE SIZE PER MANUFACTURER MID APPUCABLE CODES. MINIMUM VENT PPE SIZE TO BE 11(E SAME AS VENT OUTLET ON REGULATOR. INCREASER AS REQUIRED TO EQUIPMENT GAS PRESSURE REGULATOR W/VENT, PER EQUIPMENT MANUFACTURER REGULATOR TO BE INSTALLED AT LEAST 10 PPE DIAMETERS FROM BOILER MAW CAS VALVE REDUCER AS REQUIRED REMOVABLE 0140 CAP FOR MAINTENANCE ALIGN END CAPS TO ALLOW FOR CLEAN OUT OF PPE NOTES (PER IFGC 4107t 1. THE MP REGULATOR SHALL BE APPROVED AND SHALL BE SUITABLE FOR THE INLET AND OUTLET GAS PRESSURES FOR T.HE APPLICATION. 2 THE MP REGULATOR SHALL MAINTAIN A REDUCED OUTLET PRESSURE UNDER LOCKUP (N0 -FLOW) CONDITIONS. 3 THE CAPACITY OF 7110 MP REGULATOR. DETERMINED BY PUBLISHED RATINGS OF R5 MANUFACTURER, SHALL BE ADEQUATE TO SUPPLY THE APPLIANCES SERVED. 4 THE MP PRESSURE REGULATOR SHALL BE PROVIDED WITH ACCESS. WHERE LOCATED INDOORS THE REGULATOR SHALL BE VENTED TO THE OUTDOORS OR BE EQUIPPED WITH A LEN(- UNITING DEVICE, IN EITHER CASE COMPLYING WITH SECTION 410.3. 5 A TEE FIRING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED BETWEEN THE IIP REGULATOR AND ITS UPSTREAM SHUTOFF VALVE SUCH TEE FRANC SHALL BE POSITIONED TO ALLOW CONNECTION OF A PRESSURE - MEASURING INSTRUMENT MID TO SERVE AS A SEDIMENT TRAP. 6. A TEE FITTING WITH ONE OPENING UPPED OR PLUGGED SHALL BE INSTALLED NOT 1E55 THAN 10 PPE DIAMETERS DOWNSTREAM OF THE MP REGULATOR OUTLET. SUCH A TEE FITTING SHALL BE POST110NED TO ALLOW CONNECTION OF A PRESSURE - MEASURING DACE. `10 RE IN WITH MORONIC SYSTEM UPSTREAM OF AIR SEPARATOR atik NOT TO SCALE 111 'i[v. 11001 1. BL515 OF DESIGN: SPIRDVENT 2. REFERENCE 2/45.2 FOR BRACING DETAIL AIR / DIRT SEPARATOR DETAIL NOT TO SCALE FLANGED CONNECTION AT BASKET FILTER (17?) PROVIDE LOW POINT W WIRING TO PREVENT M051UR FROM TRAVELING DOWN WORE MID INTO UNIT ALIGN PIPE TO SLOPE 0 1/4' / FT ALONG ENTIRE LENGTH CONTROL 804NG FLOW METER PVC V, C PPE PIPE OI 2 THRO BOLT FRO4 FIANCE TO FLANGE 4'I SCH PVC PIPE 80 DRAIN TO SUMP PT REUR OVABLE END UAITENANCE CAP FO ro OPEN 3%S NLLY OPEN MIFIUUY STRAIGHT GATE VALVE PIPE FLANGED CONNECTION FOR METER INSTALLATION KEY NOTES 0 INSTALL METER PER MANUFACTURES RECD<MENOATIONS. 2X0 TO ANY VALVE, TEE OR ELBOW GROUNDING RINGS HORIZONTAL -\ ELECTRODE PLANE - -0 - CORRECT POOL DRAIN METER INSTALLATION DETAIL NOT TO SCALE 3/4' DRAIN VALVE WITH WALE ADAPTER AND CAP WELD NECK FIANCE (IMP) H PROVIDE CHAIN OPERATOR P VALVE IS 84" AFF AND PIPE S 6' OR LARGER OW) CIRCUIT BALANCING VALVE FLANGED CHECK VALVE SILENT NON- SLAMMING 4f I MINIMUM 24" SPOOL PIECE 5 PPE DIA P POSSIBLE wax SPHERE FLEX CONNECTION (TYP) 1/2 INSTRUMENT PIPING (TIP) 1/Y BAIL VALVE (TYP PULP FLANGE TAP (TIP) PROVIDE SPOOL PIECE P NEEDED FOR CLEARANCE ALIGNMENT REWIRED PR10R TO STARTUP REFERENCE 3/445.2 FOR CONNECTION DETAILS WI-STRUT MID STRAP WITH EXPANSION ANCHORS INTO 51A8 FOR PPE BRACING. LOCATE STRAP AGAINST INSIDE CORNER OF PIPE TO RESTRICT MOVEMENT ALONG EWE OF PIPE VERTICAL ELECTRODE PLWEJ ' INCORRECT Of Year Bulling REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2012 City of Tukwila BUILDING DIVISION SEE FL00R PUNS FOR PPE SIZES ALL VALVES ARE FULL SIZE OF PIPE STRAINER 1620140 FINED PRESSURE GAUGE WITH NEEDLE O')U00N VALVE SUBMITTAL TO SPECIFY PRESSURE RANGE LOCATE 2 -0' AFF MAX 1/2• P/T PORT (TIP 2) LUG STYLE BUTTERFLY ISOLATION VALVE (TYP) REDUCER SPOOL (TYP) SUCTION DIFFUSOR, MATCH INLET TO PIPE SZE MAINTAIN CLEAR ACCESS FOR STRAINER REMOVAL SPACE PROVIDE FINE MESH CONSTRUCTION STRAINER DURING STARTUP REMOVE BEFORE BALANCING 3/4' DRAM WITH BALL VALVE HOSE ADAPTER AND CAP SUPPORT LEG HOUSEKEEPING PAD E1D�s: 1 GAUGE TAPS IN PUMP AND SUCTION DIFFUSER MAY BE USED INSTEAD OF PROVIDING THREAD- 0-LE1S FOR PRESSURE GAUGE 2. PROVIDE MINIMAL DISIANCE BETWEEN HOUSEKEEPING PAD AND INERTIA BASE, I -1/2' MINIMUM, OR PER ACOUSTICAL ENGINEER. 3. PRE -EXTEND FLEXIBLE CONNECTORS ON PUMP DISCHARGE PER MANUFACTURERS INSTALLATION INSTRUCTIONS. 4. USE FIAT FACE FLANGE AND FULL FACE GASKET AT CLASS 125 OR 250 FIANCE FACES. USE RASED FACE FIANCE AT CLASS 150 OR 300 FLANGE FACES. END SUCTION PUMP DETAIL WITH INERTIA BASE CONSTANT VOLUME PUMP (NO VFD) NOT TO SCALE CORRECTION P&12 SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE. WA 98124 1- 800 -669 -6223 PDRTIAND: 16790 NE MASON ST PORTIAND. OR 97230 503- 331 -0234 .w.mctimiry.com PROJECT: TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING 1 POOL REGISTRATION: RECtisit .) CITY OF TUK\MLwA NOV 0 6 2012 PERMIT CENTER REVISIONS 8/7/12 50% DD 9/4/12 757. CD'S 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS 1&10/29/12 REVISION 1_ N0. DATE DESCRIPTION MCKINSTRY DMS10N: ENGINEERING DESIGNED BY: ARLISS MERRELL DRAWN 87: TIM WHITE CHECKED BY: SETH DAVIS JOB NUMBER: C1O256 DATE: 7/31/12 SCALE: AS SHOWN SHEET TITLE: MECHANICAL DETAILS NU R: M5.0 For Th U6Stly • ife 01 roar Building 6 November 2012 Re: Tukwila Building Division Dear Dave Larson, Senior Plan Examiner: 1 McKinstry and its consultants have reviewed the Code Review comments issues on 25 October 2012 and offer the following responses. Please also see the revised drawings associated with the revisions mentioned below. 1. ADA showers are to remain. Only plumbing fixtures are being replaced. 2. Detail has been revised. Please see Revision 1, dated 10 -29 -2012 for updated notes on 4/M5.0. 3. Regarding the backflow device on sheet MD6.1, this equipment, and associated piping, is existing per the record mechanical drawings dated 6 -29 -1990. The RPBP is shown for reference purposes, there is no work being performed on the RPBP. 4. There are no new backflow devices being installed as part of this scope. There are no known issues with the existing backflow devices. Sincerely, David Robinaugh McKinstry Co Enclosures: Revised sheet M5.0 RECEIVED CITY OF TUKIJILA NOV 0 6 2012 PERMIT CENTER 5005 3id Ave S. • Seattle, WA 98134. 206 - 762 -3311 Colorado • California • Idaho • Kansas • Minnesota • Montana • Oregon • Texas • Washington • Wisconsin City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director October 26, 2012 Dave Robinaugh McKinstry Company 5005 Third Av S Seattle, WA 98134 RE: Correction Letter #1 Plumbing /Gas Piping Permit Application Number PG12 -189 City of Tukwila Pool — 4414 S 144 St Dear Mr. Robinaugh, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. The Planning and Public Works Department have no comments at this time. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File: PGI2 -189 W:\Pennit Center \Correction Letters\2012\PG12 -189 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: October 25, 2012 Project Name: City of Tukwila Pool Permit # PG12 -189 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. There are two showers, one men's and one women's, that are shown as ADA showers. If one or both are completely replaced they will need to meet current accessibility standards. Please confirm and if applicable, provide specific details that meet section 608 of ICC /ANSI A117.1. 2. Please revise detail 4 on sheet M5.0 to include all 6 requirements noted in the IFGC section 410.2 MP Regulators. 3. Page MD6.1 has a backflow device (RPBP) with a bypass loop. It is not clear what the scope of work is. The loop needs to be protected with an additional backflow device or the loop should be removed if not needed. 4. Are there any new backflow devices? Please provide make and model number with spec sheets. If using existing backflow devices is the required testing up to date? Should there be questions concerning the above information please contact the Building Division at 206- 431 -3670. OPERMIT COORD COFi PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG12 -189 DATE: 11/06/12 PROJECT NAME: CITY OF TUKWILA - POOL SITE ADDRESS: 4414 S 144 ST Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Building Division I �� Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11/08/12 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUESITHURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ DUE DATE: 12/06/12 Approved with Conditions [ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PEA CO D COO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG12 -189 DATE: 10 -10 -12 PROJECT NAME: CITY OF TUKWILA - POOL SITE ADDRESS: 4414 S 144 ST X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPAR ME TS: L- r ev<t 10- S-4)-- BEM i g DI ision Fire Prevention N�* 19. s ►'1-- Public Works Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete DUE DATE: 10-11 -12 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ LETTER OF COMPLETENESS MAILED: Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route n Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ DUE DATE: 11 -08 -12 Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: VV Documents /routing slip.doc 2 -28 -02 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 11 I.4.12-017_ 20 ❑ Response to Incomplete Letter # Plan Check/Permit Number: PG 12 -189 Response to Correction Letter # 1 Revision requested by a City Building Inspector or Plans Examiner Project Name: City of Tukwila - Pool Project Address: 4414 S 144 St Contact Person:b ve- "iac‘o� (•� Summary of Revision: l-7..11," — Sv YeAASic9✓' I ?iep- — alADA 4 l•ems4.4f. Phone Number: 2b(0-8B2_-gSs . 4ECEIVEb UI NOV 062012, PERMIrCENTEA Sheet Number(s): 1-k . (D "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit �� Center by: Entered in Permits Plus on t1, Y "`�' ✓1r \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople Printer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with MI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MCKINSTRY CO LLC UBI No. 602569922 Phone 2067623311 Status Active Address Po Box 24567 License No. MCKINCL942DW Suite /Apt. License Type Construction Contractor City Seattle Effective Date 3/16/2006 State WA Expiration Date 3/16/2014 Zip 98134 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LYDIGML901JLLYDIG+ MCKINSTRY LLC Construction Contractor General Unused 4/13/2010 4/13/2014 Active WESTVI'121RF WESTVENT INC Construction Contractor General Unused 12/6/1988 9/1/1994 Archived MCKIN "372ND MCKINSTRY CO Construction Contractor General Unused 8/20/1963 1/2/2008 Re Licensed Business Owner Information Name Role Effective Date Expiration Date PEDERSEN, JAMIE D Agent 03/16/2006 Bond Amount ALLEN, DEAN CHARLES Partner /Member 03/16/2006 929519469 MOORE, DOUGLAS JAMES Partner /Member 03/16/2006 ALLEN, DAVID EDWARD Partner /Member 03/16/2006 WESTERN SURETY CO TEPLICKY, JOSEPH WILLIAM Partner /Member 03/16/2006 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 Western Surety Co 929519469 03/01/2011 Until Cancelled 01/23/2012 $12,000.00 02/24 /2011 2 WESTERN SURETY CO 929511574 09/09/2010 Until Cancelled $12,000.00 09/02 /2010 1 TRAVELERS CAS 8 SURETY CO 104702039 01/03/2006 Until Cancelled 03/01/2011 $12,000.00 03/16/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Zurich American Ins Co GLA-3999903 01/31/2012 01/31/2013 $2,000,000.00 12/16/2011 4 ZURICH AMERICAN INS CO GLA3999903 01/31/2011 01/31/2012 $2,000,000.00 12/20/2010 3 ZURICH AMERICAN INS CO CP0399990301 01/31/2009 01/31/2011 $2,000,000.0012 /07/2009 2 ZURICH AMERICAN INS CO CP03999903 01/31/2008 01/31/2009 $2,000,000.00 01/31/2008 1 DTC052D7193C0F07 01/31/2006 01/31/2009 $1,000,000.00 01/08/2008 https://fortress.wa.gov/lni/bbip/Printaspx 11/13/2012 ABBREVIATIONS GENERAL AD AW AFT AFG AG AMP ARCH AUTO AUX BD BHP BLDG BOP 85 6U H CA CAB COND C/L CLG CFM CLG CO CO2 COL CONC COND CONN CONSTR COMM CTL DET DIA DIAG DIM DISCH DIV DN DS DWDI DWG DWV EA EC EL EEC BEV EQUIP ESP EXH EXIST (F) FA F FDC FDN FIG FIN FIO FLEX FIG RR FO FP FPM FT FTG FURN GALV GC GEN GPM GwB HP HR HS HTG MR ID LAB tr MAX MBH MED MEZZ MFR MH MIN MSC MTO N/A NEG NIC NO NOM NETS OA OC OD OVHD POC PRELIM PSI PSIG QTY R RAD REQD RPM SECT SF SIM SPEC SQ STD STRUC ACCESS DOOR ADJUSTABLE ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ABOVE GROUND AMPERE ARCHITECT; ARCHITECTURAL AUTOMATIC AUXILIARY BOARD BRAKE HORSEPOWER BUILDING BOTTOM OF PIPE BOTRTOM SCREEN BRMSH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR COMPRESSED AIR CABINET CONDENSATE CENTER LINE CEIUNG CUBIC FEET PER MINUTE CEIUNG CARBON MONOXIDE CARBON DIOXIDE COLUMN CONCRETE CONDENSER; CONDENSATE CONNECT; CONNECTION CONSTRUCTION CONTRACTOR CONTROL DETAIL DIAMETER DIAGONAL DIMENSION DISCHARGE DMSION D SCONNECT SWITCH; DOOR SWITCH DOUBLE WIDTH, DOUBLE INLET DRAWING DRAIN, WASTE, VENT EXISTING EACH ELECTRICAL CONTACTOR; END CAP ELEVATION ELECTRICAL ELEVATION ELECTRICAL PANEL; END PLUG EQUIPMENT EXTERNAL STATIC PRESSURE EXHAUST EXISTING FUTURE FAHRENHEIT FIRE ALARM FLOOR CLEANOUT FIRE DEPARTMENT CONNECTION FOUNDATION FIGURE FINISH FURNISHED AND INSTALLED BY OWNER FLEXIBLE FLANGE FLOOR FUEO. OIL ARE PROTECTION FEET PER MINUTE FOOT; FEET FOOTING FURNISH GGAALL.VANIZED GENERAL CONTRACTOR GENERATOR GALLONS PER MINUTE GYPSUM WALL BOARD HIGH HORSEPOWER; HIGH PRESSURE HEATING RETURN HEATING SUPPLY HEATING HEATER INSIDE DIAMETER /DIMENSION LABORATORY UNFAL FOOT MAKE -UP AIR UNIT MAXIMUM 1000 BRITISH THERMAL UNITS PER HOUR MEDIUM MEZZANINE MANUFACTURER MANHOLE MINIMUM; MINUTE(S) MISCELLANEOUS MOUNTED NOT APPLICABLE NORMALLY CLOSED NEGATIVE NOT IN CONTRACT NORMALLY OPEN; NUMBER NOMINAL NOT TO SCALE OVERALL ON CENTER OUTSIDE DIAMETER OVERHEAD POINT OF CONNECTION PRELIMINARY POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE QUANTITY RELOCATED RADIUS REQUIRED REVOLUTIONS PER MINUTE SECTION SQUARE FOOT SIMILAR SPECIFICATION SQUARE STANDARD STRUCTURAL inD TOC TOS TYP UG UNO VAV VD VEER VED VSD w w/o HVAC AC ACT AHU BDD BOD CC CRU CT CV DB DIFF DMPR EA EAT ECG EF FCU FD FM FP FEU GRD HC HR IWAC TO BE DETERMINED TENANT IMPROVEMENTS TOP OF CONCRETE TOP OF TYPICAL STEEL UNDERGROUND UNLESS NOTED OTHERWISE VARIABLE AIR VOLUME VOLUME DAMPER IFY VARIABLE FREQUENCY DRIVE VARIABLE SPEED DRNE WITH WITHOUT AIR CONDITIONING ACOUSTICAL CEILING TILE AIR HANDLING UNIT BACKDRAFT DAMPER BOTTOM OF DUCT COOLING COIL COMPUTER ROOM UNIT COOLING TOWER CONSTANT VOLUME DRY BULB DIFFUSER DAMPER EXHAUST AIR ENTERING AIR TEMPERATURE EGGCRATE GRILLE EXHAUST FAN FAN COIL UNIT FIRE DAMPER FREQUENCY MODULATION FIRE PROTECTION; FAN POWERED FAN TERMINAL UNIT GRILLE, REGISTER, DIFFUSER HEATING COIL HEATING RETURN HEATING, VENTILATION AND AIR CONDITIONING LAT LEAVING AIR TEMPERATURE LD LINEAR DIFFUSER MC MECH MOD MUA MECHANICAL CONTRACTOR MECHANICAL MOTOR OPERATED DAMPER; MODULATING MAKE UP AIR OA OVERALL; OUTSIDE AIR 0BD OPPOSED BLADE DAMPER RA RAT RCP RIu SA SAT SD SF S/FD SLSM SM SP TDH TG TOD TSP UH WB WC WG RETURN AIR • RETURN AIR TEMPERATURE REFLECTED CEILING PLAN ROOF TOP UNIT SUPPLY AIR SUPPLY AIR TEMPERATURE SMOKE DAMPER SUPPLY FAN SMOKE FIRE DAMPER SOUND UNED SOUND UNED SHEET 'METAL SHEET METAL STATIC PRESSURE TOTAL DYNAMIC HEAD TRANSFER GRILLE TOP OF DUCT TOTAL STATIC PRESSURE UNIT HEATER WET BULB WATER COLUMN WATER GAUGE PLUMBING AD AREA DRAIN CO DCW DHW DHWC DSP EWC FD IE IN WC RV NPCW ORL PD PERF PI.BG PRV RPBP SD SS VTR WC WSP PIPING BP CD CHW CHR CHS CT EWT FM/ LWT TOP CLEAN OUT; CARBON MONOXIDE DOMESTIC COLD WATER DOMESTIC HOT WATER DOMESTIC HOT WATER RECIRCULATION DRY STANDPIPE ELECTRICAL WATER COOLER FLOOR DRAIN INVERT ELEVATION INCHES WATER COLUMN IONIZED WATER; INDIRECT WASTE NON POTABLE COLD WATER OVERFLOW RAINWATER LEADER PLANTER DRAIN; PRESSURE DROP PERFORATED PLUMBING PRESSURE REDUCING VALVE REDUCED PRESSURE BACKFLOW PREVENTER STORM DRAIN SANITARY SEWER VENT THROUGH ROOF WASTE WATER CLOSET WATER HEATER WET STANDPIPE BACKFLOW PREVQNTFJR CONDENSATE DRAIN CHILLED WATER CHILLED WATER RETURN CHILLED WATER SUPPLY CONICAL TEE ENTERING WATER TEMPERATURE FIRE HOSE VALVE LEAVING WATER TEMPERATURE TOP OF PIPE PIPING IDENTIFICATION HVAC PLUMBING A COND -CDR- CDS CHS -CHR- G 115 RL ST GRW GAW 10 RR NP ORL PSD RWL —101/L— SD SS UD� _V_,. W W PIPING FITTINGS ItI 10 Il IX' x LT }}I t . .f 1 1 VALVES PI A oI Pail IJ4 PIPING ACCESSORIES 4AV Li O �4. WATTS/LF RPBP Y 0 NMI 11111 A COND CDR CDS CHS CHR G HR HS RL RS sr GRW GAW HW HWC ID IRR NPCW ORL PW D RWL RWL SD SS UP V w COMPRESSED AIR PIPE 'CONDENSATE DRAIN PIPE CONDENSER WATER RETURN PIPE CONDENSER WATER SUPPLY PIPE CHILLED WATER SUPPLY PIPE CHILLED WATER RETURN PIPE NATURAL GAS PIPE HEATING WATER RETURN PIPE HEATING WATER SUPPLY PIPE REFRIGERANT UQUID PIPE REFRIGERANT SUCTION PIPE STEAM SUPPLY COLD WATER PIPE (POTABLE) GREASE WASTE GARAGE WASTE HOT WATER PIPE (POTABLE) HOT WATER CIRCULATING (POTABLE) INDIRECT DRAIN IRRIGATION WATER PIPE NON - POTABLE CW PIPE OVERFLOW RAINWATER LEADER PUMPED WASTE PUMPED STORM DRAIN RAINWATER LEADER BELOW GRADE RAINWATER LEADER STORM DRAIN PIPE SANITARY SEWER PIPE (SITE) UNDERDRAIN PIPE VENT PIPE (SANITARY) WASTE PIPE WASTE PIPE BELOW GROUND TEE W /PIPE UP TEE DOWN W /ELBOW TEE UP W/ ELBOW TEE UP TEE DOWN 90' ELBOW UP 90' ELBOW DN CAP UNION FLANGE R.EX HOSE CONNECTION DOUBLE BELLOWS FLEX CONNECTION SINGLE BELLOWS FLEX CONNECTION FLOW ARROW CONCENTRIC REDUCER ECCENTRIC REDUCER SLOPE SYMBOL BREAK OR CONTNUATION SYMBOL DOWN SPOUT NOZZLE CLE/NOUT 45' ELBOW 45 ELBOW 90' EL BOW 90' ELBOW CROSS TEE WYE TAP HOSE CONNECTION MOTORIZED 2 -WAY VALVE MOTORIZED 3 -WAY VALVE PRESSURE REDUCING VALVE CONTROL VALVE RELIEF VALVE BALI. VALVE 3 -WAY GATE VALVE BUTTERFLY VALVE DIAPHRAGM VAVVE CHECK VALVE NEEDLE VALVE GLOBE VALVE GLOBE VALVE ANGLE GLOBE VALVE 3 -WAY GATE VALVE PLUG VALVE BALANCING VALVE HOSE BBB PUMP MANUAL AIR VENT AUTOMATIC AIR VENT HIGH CAPACITY AIR VENT SHOCK ARRESTOR FLOW SWITCH VACUUM BREAKER PRESSURE GAUGE TEMPERATURE SENSOR TEMPERATURE INDICATOR AUTO FLOW VALVE FLOW METER Y STRAINER Y STRAT � iNER W/ BALL. VALVE PIPE SLEEVE STEAM TRAP PETES PLUG HEAT 'TRACING SUCTION DIFFUSER W/ STRAINER REDUCED PRESSURE BACKFLOW PREVENTOR FUNNEL. DRAIN FLOOR DRAIN ROOF DRAIN ROOF OVERFLOW DRAIN FLOOR SINK REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOT Revisions will require a new plan submtltal end may include additional plan review fees. DUCTWORK ACCESSORIES =]:13 {HOC BIRDSCREEN OR SCREENED OPENING SUPPLY GRIUE RETURN OR EXHAUST GRILLE VOLUME DAMPER MOTOR OPERATED DAMPER AIRFLOW MONITOR REMOTELY OPERATED VOLUME DAMPER (YOUNG REGULATOR OR APPROVED) BACK DRAFT DAMPER COORDINATE WITH CEIUNG APPURTENANCES. FLEX CONNECTION FIRE DAMPER THROUGH WALL ---� FIRE DAMPER THROUGH FLOOR FIRE /SMOKE DAMPER THROUGH WALL FIRE /SMOKE DAMPER THROUGH FLOOR ACCESS DOORS • 12x12 SL 12x12 2 *SL ormemoomallo —I 1 DUCTWORK RECTANGUIAR DUCT RECTANGULAR DUCT RECTANGULAR DUCT RECTANGULAR DUCT r ACOUSTICALLY LINED DUCT 2' ACOUSTICALLY UNED DUCT CHANGE OF ELEVATION RISE(R) DROP(D) TRANSITION TURNING VANES SMOKE DETECTOR RETURN / EXHAUST / OUTSIDE AIR SUPPLY / TRANSFER AIR TERMINAL UNITS - SEE SCHEDULE FOR TYPE SUPPLY AIR DUCT TURNING UP OR TOWARD SUPPLY AIR DUCT TURNING DOWN OR AWAY EXHAUST OR RETURN AIR DUCT TURNING UP OR TOWARD EXHAUST OR RETURN AIR DUCT TURNING DOWN OR AWAY F—Gb ROUND DUCT TURNING UP OR TOWARD ROUND DUCT TURNING DOWN OR AWAY OVAL DUCT TURNING UP OR TOWARD OVAL DUCT TURNING DOWN OR AWAY FLEXIBLE DUCT HVAC - ANNOTATION VAV BOX TAG 1 -23 S-C8-09-A 000 S -C8 -1 A FLOOR 1 - DISCRETE BOX SEE BELOW • PRIMARY .CFM FAN CFM ACOUSTICAL ACCESSORIES (IF REQ'D) KW OF AUX. HEAT. VAV BOX SIZE; SEE SCHED. SERIES ARLLE. FANPPWEERRED BOX�)(P) GRILLE /REGISTER/DIFFUSER DOUBLE LINE CEIUNG SUPPLY AIR DIFFUSER CEIUNG SUPPLY AIR DIFFUSER (SHOWN WITH THROW ARROWS) CEIUNG RETURN, EXHAUST OR TRANSFER AIR GRILLE UNEAR DIFFUSER ( CEIUNG) UNEAR DIFFUSER (WAU.) LOUVER PLAN VIEW LOUVER (ELEVATION VIEW) CONTROLS LEGEND DEVICE/POINT SEPARATE PERMIT REQUIRED FOR: 4Methardcal Et Electrical D Plumbing D Gas Plpkig City of Tukwila BUILDING DIVISION A ADS AMS ATB CO CPA CS DPS DS sD DSO EC EA EAV EF E/P 9i' FZ FHV H HL LL MA MOD. OR [3741,044- D9:1 El NC NO OS OA 9 OR at4r ' I1 PA PF PS RA S SA SAV 55 SP TS VFD NUMBER ALARM AIR DIRT SEPARATOR AR FLOW MEASURING STATION AIR TERMINAL BOX CARBON DIOXIDE SENSOR CARBON DIOXIDE CARBON MONOXIDE CONTROL POINT ADJUSTMENT CURRENT SENSING RELAY MC CONTROL RELAY DIFFERENTIAL PRESSURE SENSOR VICINITY MAP DIFFERENTIAL PRESSURE SENSOR DOOR SENSOR DUCT SMOKE DETECTOR DUCT SMOKE DETECTOR ELECTRIC HEATING COIL EXHAUST AIR EXHAUST AIR VALVE EXHAUST FAN ELECTRONIC TO PNEUMATIC SIGNAL CONVERSION. FAN OR PUMP FINAL FILTER FREEZE STAT FUME HOOD VALVE HUMIDITY SENSOR HUMIDITY SENSOR HIGH LIMIT LOW UMIT MIXED AIR MODULATING SIGNAL MOTOR OPERATED DAMPER MOTOR OPERATED CONTROL VALVE MOTOR STARTER NORMALLY CLOSED NORMALLY OPEN OCCUPANCY SENSOR OUTSIDE AIR PNEUMATIC OPERATED DAMPER PNEUMATIC OPERATED CONTROL VALVE PRIMARY AIR PRE FILTER PRESSURE SENSOR PUMP RETURN AIR STATUS SUPPLY AIR SUPPLY AIR VALVE Date, 1 t ('� LEGAL DESCRIPTION 1 W 190 FT OF E 565 FT OF S 320 FT OF SW 1/4 OF SE 1/4 LESS CORD DRAWING INDEX SHEET NUMBER SHEET TITLE MO.0 MECHANICAL LEGEND MO.1 GENERAL NOTES AND BASIS OF DESIGN MD2.0 FLOOR PLAN - MECHANICAL DEMO M2.0 FLOOR PLAN - MECHANICAL M2.1 ROOF PLAN - MECHANICAL • M3.0 ENLARGED BOILER ROOM MECHANICAL PLANS M3.1 ENLARGED FILTER ROOM MECHANICAL PLANS 2 LA: ' • IR . ` R ROOM MECHANICAL PLANS 5. ME HANICAL ' ETAILS .1 ' EC- ' CAL ' AI S M5.2 EQUIPMENT CONNECTION DETAILS M6.0 HEATING WATER PIPING AND CONTROLS DIAGRAMS MD6,1 PLUMBING ONE -LINE DIAGRAM -DEMO M6.1 PLUMBING ONE -LINE DIAGRAM M7.0 EQUIPMENT SCHEDULES M7.1 EQUIPMENT SCHEDULES M7.2 EQUIPMENT SCHEDULES GENERAL INFORMATION SYMBOLS X • FILE COPY _. Permit No., ff-71(2---'1 , Pim review approval is subject to errors and omissions. Approval of constuctIon documents does not authollz3 the v,olation of an adopted •. _ or ordinance. Receipt Of cpprOVed . Ir` W By - START /STOP SASH POSITION SENSOR TEMPERATURE SENSOR TEMPERATURE SENOR VARIABLE FREQUENCY DRIVE VARIABLE FREQUENCY DRIVE City Of'�ukwffa BUILDING DIVISION EQUIPMENT TAG IEF-2-11 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2012 City o Tu Wila BUILDIN VISION NEW MECHANICAL WORK EXISTING MECHANICAL WORK DEMO MECHANICAL WORK DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL /DIAGRAM SHOWN PLAN NUMBER SHEET NUMBER WHERE, PLAN SHOWN REVISION NUMBER -- DENOTES NUMBER AND DATE WHEN REVISION OR ISSUE OCCURED REVISION CLOUD - DENOTES AREA OF CHANGE DETAIL REFERENCE OUTLINE WITH NUMBER AND SHEET LOCATION DRAWING NOTE REFERENCE POINT OF CONNECTION POINT OF DEMOLMON •-- CONSECUINE EQUIP. f FLOOR OF EQUIP. LOCATION EQUIPMENT DESIGNATION EQUIPMENT TAG RECEIVED CITY OF TUKWILA OCT 1 0 2012 PERMIT CENTER ?Gp 189 For Th instry Ile Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1 -800- 669 -6223 PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 -331 -0234 www.mckinsttry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: POOL RINIMMINIIIMAROMINIMMINIMMIN REVISIONS: 817/12 50% Do 9/4/12 75% CD'S 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING ARUSS MERRELL TIM WHITE SETH DAVIS C10256 7/31/12 AS SHOWN MECHANICAL LEGEND SHEET NUMBER: M0.0 GENERAL NOTES: 1. THE CONTRACTOR IS RESPONSIBLE TO VISIT THE SITE AND DETERMINE NE EXACT EXTENT OF WORK, COORDINATION, DEMOLITION, TEMPORARY CONSTRUCTION, TEMPORARY FACILITIES, ETC, NECESSARY TO COMPLETE THE PROJECT AS INDICATED IN THE CONTRACT DOCUMENTS. 2. INTERRUPTIONS OF SERVICES (POWER, WATER, HVAC, ETC.) AND WORK IN OCCUPIED TENANT SPACES MUST BE SCHEDULED THRU THE BUILDING MANAGER A MINIMUM OF 24 HOURS IN ADVANCE. ANY INTERRUPTIONS OR CONSTRUCTION WHICH WILL AFFECT NORMAL OPERATION OF THE BUILDING OR TENANTS MUST BE SCHEDULED, WITH THE BUILDING MANAGER'S APPROVAL ON AN AFTER -HOURS BASIS. 3. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR TEMPORARY HEAT DURING CONSTRUCTION. PERMANENT MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY HEAT WITHOUT PROTECTION FROM DUST ACCUMULATION, WRITTEN ACCEPTANCE OF DUST RELATED WARRANTY COSTS, AND PRIOR APPROVAL BY THE MECHANICAL ENGINEER, 4. FURNISH LABOR, MATERIALS, EQUIPMENT, APPARATUS AND APPURTENANCES REQUIRED FOR A COMPLETE WORKING AND COORDINATED SYSTEM. MATERIALS, EQUIPMENT, APPARATUS, AND APPURTENANCES SHALL MATCH EXISTING BUILDING STANDARDS IN QUALITY, TYPE AND FINISH, UNLESS OTHERWISE NOTED. 5. VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT. COORDINATE THE EXACT LOCATIONS OF NEW MECHANICAL MD PLUMBING EQUIPMENT WITH THE LOCATIONS OF LIGHTING FIXTURES, PIPING, AND OTHER CONSTRUCTION, TO ALLOW FOR PROPER ACCESS TO SERVICE AND MAINTAIN EQUIPMENT PRIOR TO START OF CONSTRUCTION. 6. COORDINATE THE LOCATION OF DUCTWORK AND PIPING WITH .OTHER TRADES. PROVIDE OFFSETS IN DUCTWORK AND PIPING AS REQUIRED AT NO ADDITIONAL COST TO OWNER. 7. TRADES TO LEAVE 36" CLEARANCE IN FRONT OF MECHANICAL EQUIPMENT ACCESS PANELS FOR SERVICING. 8. INSTALL DUCTWORK AND PIPING TO ALLOW MINIMUM ACCESS OF 6" ABOVE AND TO THE SIDE OF THE ELECTRICAL CABLE TRAYS. 9. SUPPORT CONDUIT, PIPING, AND DUCTWORK INDEPENDENTLY. SUPPORTS ARE INDEPENDENT OF PART1TiON AND CEILING SYSTEM SUPPORTS. 10. IN NO INSTANCE SHALL OTHER TRADES HANG OR SUPPORT EQUIPMENT, CEILING WIRES, LIGHT FIXTURE HANGERS, ETC., FROM HVAC EQUIPMENT, DUCTWORK, OR PIPING. . 11. CUTTING, FRAMING, PATCHING, AND PAINTING OF WALL, CEILING, AND FLOOR OPENINGS : SHALL BE BY GENERAL CONTRACTOR. THIS INCLUDES OPENINGS THROUGH AREA SEPARATION WALLS 12. OBTAIN WRITTEN APPROVAL OF. STRUCTURAL ENGINEER PRIOR TO INSTALLATION OF PENETRATIONS IF NOT SHOWN ON DRAWINGS. 13. REFER TO STRUCTURAL DRAWINGS FOR EQUIPMENT SUPPORTS. REFER TO THE SPECIFICATIONS MATRIX FOR ADDITIONAL SEISMIC INFORMATION. 14. UNIT WEIGHTS AND LOCATIONS HAVE BEEN COORDINATED TO DETERMINE BUILDING STRUCTURAL ADEQUACY. IF IT IS NECESSARY TO RELOCATE A UNIT, NOTIFY MCKINSTRY ENGINEERING DEPARTMENT FOR RE-- COORDINATION. 15. PROVIDE SEISMIC RESTRAINTS AND ANCHORAGE PER SMACNA AND THE INTERNATIONAL BUILDING CODE FOR DUCTWORK, PIPING, AND EQUIPMENT. 16. CONCRETE EQUIPMENT CURBS, FLASHINGS, SLEEPERS, CONCRETE STATIONS, EMBED PLATES, PIPING RAT SLABS, SUMP BASINS, AND HOUSEKEEPING PADS ARE SHOWN FOR APPROXIMATE LOCATION AND SIZE AND WILL BE PROVIDED BY THE GENERAL CONTRACTOR. 17. CUTTING AND PATCHING OF ROOF OPENINGS SHALL BE BY THE GENERAL CONTRACTOR. 18. SLEEPERS, HOUSEKEEPING PADS, EMBED PLATES, AND CANT STRIPS SHALL BE BUILT AND FASTENED TO THE ROOF BY THE GENERAL CONTRACTOR. TOP OF THE CURB MUST BE FLAT TO PROVIDE AN ACCEPTABLE SEALING SURFACE. MAXIMUM ALLOWABLE DEVIATION FROM LEVEL SHALL BE %? IN 10'. ROOF CURBS AND SLEEPERS MUST BE SECURELY FASTENED TO STRUCTURAL SUPPORT MEMBERS. 19. LOUVERS, BOTH DUCTED AND NON- DUCTED, ARE TO BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR. LOUVERS ARE SHOWN ON THESE PLANS BOTH FOR COORDINATION, AND TO INDICATE THE REQUIRED LEVEL OF PERFORMANCE. LOUVERS OF ALTERNATE MAKE AND /OR TYPE MAY BE SUBSTITUTED ONLY IF THEY HAVE BOTH PRESSURE DROP AND WATER CARRY-OVER PERFORMANCE EQUAL TO OR BETTER THAN THE LOUVERS SPECIFIED. LOUVERS MUST CONTAIN THE FREE AREA REQUIREMENT INDICATED ON THE MECHANICAL PLANS. OTHER LOUVER MODELS WITH EQUAL OR BETTER FREE AREA, . WATER CARRY-OVER, AND PRESSURE DROP MAY BE SUBSTITUTED IF APPROVED BY THE MECHANICAL ENGINEER AND ARCHITECT. 20. ALL CRANE LIFTING AND SETTING OF EQUIPMENT, PIPING, DUCTWORK, ETC. IS TO BE PERFORMED BY GENERAL CONTRACTOR. EQUIPMENT REQUIRES SPECIFIC RIGGING TO PREVENT DAMAGE. SEE EQUIPMENT SUBMITTALS FOR UFTING INSTRUCTIONS. 21. BEFORE MAKING CONNECTIONS TO THE EQUIPMENT FURNISHED BY THE OWNER OR OTHERS, VERIFY THAT EXACT INFORMATION IS PROVIDED. 22. PROVIDE PIPE, EQUIPMENT, AND VALVE LABEUNG FOR IDENTIFICATION. MATCH OWNERS EXISTING LABELING SCHEME IF APPUCABLE, 23. UGHT FIXTURE CLEARANCE: COORDINATE LOCATIONS OF MECHANICAL WORK TO PROVIDE CLEARANCES OVER UGHTING FIXTURES FOR REMOVAL AND REPLACEMENT. 24. PROVIDE MODIFICATIONS TO THE EXISTING SPRINKLER SYSTEM FOR ALL REMODEL AREAS. 25. PROVIDE FIRE SAFE PENETRATIONS OF FIRE RATED CONSTRUCTION. 26. MINIMUM VENTILATION QUANTITIES SHALL COMPLY WITH OR EXCEED THE 2009 INTERNATIONAL MECHANICAL CODE WITH THE WASHINGTON STATE AMENDMENTS. SUBMITTAL NOTES; 1. PROVIDE A HVAC /PLUMBING EQUIPMENT AND COMPONENT SUBMITTAL PACKAGE. INCLUDE IN THE PACKAGE SUBMITTALS FOR ITEMS INCLUDED ON THE SCHEDULE AND /OR SPECIFICATION. SHEETS. ALSO INCLUDE SUBMITTALS FOR VALVES, GAUGES, DAMPERS, COILS AND INSTRUMENTATION. PIECEMEAL SUBMITTALS ARE PIECEMEAL SUBMITTALS ARE NOT ACCEPTABLE. 2. PROVIDE CONTROLS SUBMITTAL PACKAGE. INCLUDE IN THE PACKAGE SUBMITTALS FOR SEQUENCE OF OPERATIONS, SYSTEM DIAGRAMS, ARCHITECTURE DIAGRAMS, PLANS, PLUS EQUIPMENT AND COMPONENTS. 3. THE PIPING CONTRACTOR SHALL PROVIDE FULL SUBMITTALS OF PIPING AND DEVICES FOR APPROVAL PRIOR TO PURCHASE AND INSTALLATION. 4. PROVIDE CONTRACTOR PREPARED SHOP DRAWINGS OF CONTRACTOR FABRICATED SHEET METAL SYSTEMS. DRAWINGS SHALL BE PREPARED AT 1/4" SCALE USING COMPUTER AIDED DESIGN (CAD) SOFTWARE UNLESS INDICATED OTHERWISE. DRAWINGS SHALL SHOW EXACT LOCATION OF EQUIPMENT AND DUCTWORK, EACH SECTION OF SHOP FABRICATED DUCT AND LOCATION OF FIELD JOINTS, SUPPORTS, AND BUILDING ATTACHMENTS, AND SEISMIC RESTRAINT LOCATIONS. ELECTRICAL COORDINATION NOTES; 1. WHERE INDICATED ON THE EQUIPMENT SCHEDULES, THE EQUIPMENT COMES COMPLETE FROM THE FACTORY WITH MOTOR CONTROLS AS REQUIRED. ELECTRICIAN SHALL PROVIDE SERVICE AND A DISCONNECT PER CODE, AND POWER WIRING, INCLUDING CONNECTING TO EQUIPMENT. 2. WHERE INDICATED ON EQUIPMENT SCHEDULES, THE EQUIPMENT REQUIRES FIELD INSTALLED MOTOR STARTERS. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL MOTOR • STARTERS (OR CONTACTORS WHERE INDICATED). PROVIDE SERVICE AND DISCONNECT PER CODE, AND POWER WIRING, INCLUDING CONNECTING TO EQUIPMENT. HOLDING COIL CIRCUIT SHALL BE POWERED BY ELECTRICAL CONTACTOR (120V UNLESS INDICATED OTHERWISE). STARTERS SHALL BE. PROVIDED WITH H -O -A SWITCH, EXCEPT SMOKE CONTROL FANS SHALL NOT HAVE HAND OFF POSI11ONS ON THE STARTERS AS .NOTED ABOVE. 3. REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS OF THE MECHANICAL EQUIPMENT, UNLESS OTHERWISE NOTED. DEMOLITION NOTES; 1. DEMOLITION DRAWINGS ARE INCLUDED TO • GIVE A COMMON BASIS FOR BIDDING AND MAY NOT SHOW EVERY ITEM TO BE DEMOLISHED. VISIT SITE TO DETERMINE AND COORDINATE THE EXACT EXTENT OF DEMOLITION TO FACEPLATE WORK INDICATED BY THE CONTRACT DOCUMENTS. REWORK EXISTING TERMINATIONS, CONNECTIONS, ETC., TO ACCEPT NEW WORK. PRIOR TO START OF ANY DEMO WORK, VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR . RESOLUTION. 2. REMOVE EXISTING HVAC EQUIPMENT AS INDICATED, INCLUDING ASSOCIATED PIPING, CONTROL SYSTEMS, AND APPURTENANCES. 3. REMOVE EXISTING DUCTWORK AS INDICATED, CAP EXISTING OPENINGS NOT BEING REUSED. 5. REMOVE EXISTING PIPING SERVING ITEMS TO BE REMOVED. CAP OR PLUG BRANCH LINES NOT BEING REUSED. 6. GIVE OWNER THE OPPORTUNITY TO RETAIN ANY REMOVED ITEMS THAT ARE NOT BEING REUSED. DISPOSE OF OTHER ITEMS LEGALLY. 7. CLEAN AND REFURBISH ITEMS INDICATED TO BE REMOVED AND REUSED PRIOR TO REUSE. PIPING NOTES; 1. BACKFLOW DEVICES, CROSS CONTROL DEVICES, VACUUM BREAKER AND DOUBLE CHECK VALVES TO BE A TYPE APPROVED BY THE STATE OF WASHINGTON HEALTH SERVICES DMSION. 2. INSTALL AIR VENTS AT HIGH POINTS IN HYDRONIC PIPING. INSTALL DRAIN VALVES IN LOW POINTS IN HYDRONIC PIPING. 3. PROVIDE FLANGES OR UNIONS AT PIPING CONNECTIONS TO EQUIPMENT, COILS, TRAPS, CONTROL VALVES, AND OTHER COMPONENTS TO ALLOW FOR MAINTENANCE. 4. PROVIDE REDUCERS AS REQUIRED FROM UNE PIPE SIZE TO EQUIPMENT, TRAP, COIL, AND CONTROL VALVE CONNECTION SIZES. 5. PROVIDE OFFSETS FOR BRANCH UNES TO EQUIPMENT TO ALLOW FOR SERVICE AND MAINTENANCE OF EQUIPMENT. 6. PROVIDE DIELECTRIC UNIONS AT CONNECTIONS OF DISSIMILAR PIPE MATERIALS. 7. PIPE SUPPLY WATER UNES TO BOTTOM OF COILS LEAVING AIR SIDE TO OBTAIN COUNTERFLOW ARRANGEMENT. 8. PROVIDE PRESSURE AND TEMPERATURE TEST PORTS AT SUPPLY AND RETURN PIPING CONNECTIONS TO EQUIPMENT. 9. SIZE BALANCING /MEASURING VALVES IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. DO NOT PROVIDE VALVES LARGER THAN UNE SIZE. 10. SYSTEM FILL: 0. AFTER COMPLETION OF PIPING SYSTEM INSTALLATION AND PRESSURE TESTING, AND BEFORE MAKING CONNECTIONS TO EQUIPMENT, REMOVE TRACES OF DIRT, OIL, PIPE JOINT COMPOUND, ETC. BY FLUSHING PIPE SYSTEM WITH MCKINSTRY APPROVED CLEANER AND RUNNING CIRCULATION PUMPS. DRAIN, RE -FILL, AND RE -FLUSH SYSTEM IN ORDER TO REMOVE ALL TRACES OF CHEMICAL CLEANER. b. AFTER SYSTEM HAS BEEN THOROUGHLY CLEANED AND PRESSURE TESTED, FILL WITH A MIXTURE OF WATER AND THE APPROPRIATE CORROSION INHIBITORS. SUBMIT MIXTURE AND SEND TO MANUFACTURER'S LABORATORY FOR ANALYSIS. ADD WATER AND /OR INHIBITOR AS DIRECTED BY LAB REPORT. SUBMIT FINAL LAB REPORT TO MCKINSTRY ENGINEERING DEPARTMENT. c. RUN PUMPS TO CIRCULATE UNTIL THOROUGHLY MIXED AND AIR HAS BEEN PURGED FROM SYSTEM. THEN, DRAW A SAMPLE OF MIXTURE AND SEND TO MANUFACTURER'S LABORATORY FOR ANALYSIS. ADD WATER AND /OR INHIBITOR AS DIRECTED BY LAB REPORT. SUBMIT FINAL LAB REPORT TO MCKINSTRY ENGINEERING DEPARTMENT. d. PRESSURIZE SYSTEM ACCORDING TO THE FOLLOWING SCHEDULE AND LEAVE FILL VALVE CLOSED: HEATING WATER SYSTEM FILL PRESSURE: 25 PSIG HEATING WATER SYSTEM REUEF VALVE SETTING: 50 PSIG PLUMBING NOTES; 1. INSTALL PIPED UTILITIES ON WARM SIDE OF BUILDING INSULATION WHERE THE SERVICE IS SUBJECT TO FREEZING TEMPERATUR REVCp PL FOR CE CODE APPROVED NOV 0 8 2012 2. PROVIDE INDIRECT DRAIN PIPING FROM REDUCED PRESSURE BACKFLOW PREVENTER (RPBP) TO NEAREST DRAIN. INSTALL FUNN I REQUIRED. City of Tukwila DIVISION 3. PROVIDE CLEANOUTS AS REQUIRED BY PLUMBING CODE. INSTALL CLEANOUTS IN THE FLOOR OR WALL OF THE FLOOR ABOVE FOR PIPES THAT ARE DIFFICULT TO ACCESS. LOCATE FLOOR CLEANOUTS IN CORRIDORS, TOILET OR JANITOR ROOMS WHEREVER POSSIBLE. SHEET METAL NOTES; 1. PROVIDE DUCTWORK IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE, SECOND EDITION, 2005 ( SMACNA HVACDCS). 2. DUCT SIZES INDICATED ARE INSIDE CLEAR DIMENSIONS. 3. PROVIDE A MANUAL VOLUME DAMPER FOR EACH SUPPLY, RETURN, AND EXHAUST OPENING EXCEPT WHERE PROHIBITED BY CODE. INSTALL AS FAR FROM INLET OR OUTLET AS POSSIBLE. 4. PROVIDE FLEXIBLE CONNECTION AT EACH DUCT CONNECTION TO FANS, AIR HANDUNG UNITS, AND SIMILAR EQUIPMENT. DO NOT INSTALL ON EQUIPMENT LOCATED IN FIRE RATED CORRIDOR CEILING. 5. DUCT SMOKE DETECTORS: LOCATE DUCT SMOKE DETECTORS IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. COORDINATE LOCATION REQUIREMENTS WITH ELECTRICAL. WASHINGTON STATE ENERGY CODE NOTES; 1. PROVIDE COMMISSIONING PLAN IN ACCORDANCE WITH 2009 WASHINGTON STATE ENERGY CODE SECTION 1416.3.1. 2. PROVIDE SYSTEMS TESTING AND BALANCING IN ACCORDANCE WITH 2009 WASHINGTON STATE ENERGY CODE SECTION 1416.3.2. 3. PROVIDE SYSTEMS, EQUIPMENT, AND CONTROLS FUNCTIONAL TESTING IN ACCORDANCE WITH 2009 WASHINGTON STATE ENERGY CODE SECTION 1416.3.3. 4. PROVIDE SUPPORTING DOCUMENTATION IN ACCORDANCE WITH 2009 WASHINGTON STATE ENERGY CODE 1416.3.4 INCLUDING OPERATION AND MAINTENANCE MANUALS, HVAC CONTROL SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, HVAC CONTROL SEQUENCE OF OPERATIONS, COMMISSIONING REPORT, AND RECORD DRAWINGS. , , 5. PROVIDE OWNER SYSTEMS OPERATION TRAINING IN ACCORDANCE WITH 2009 WASHINGTON STATE ENERGY CODE SECTION 1416.3.4.3. 6. PROVIDE COMMISSIONING COMPUANCE FORM IN ACCORDANCE WITH 2009 WASHINGTON STATE ENERGY CODE SECTION 1416.4. 7. MOTORS SHALL COMPLY WITH CHAPTER 15 OF THE 2009 WASHINGTON STATE ENERGY CODE. FOR ADOIFIONAL DETAILS, SEE EQUIPMENT SCHEDULES CONTAINED WITHIN THIS DRAWING SET. 8. SYSTEMS SHALL BE INSULATED AS PRESCRIBED IN CHAPTER 14, TABLE 14 -5 OF THE 2009 WASHINGTON STATE ENERGY CODE. FOR ADDMONAL DETAILS, SEE DUCTWORK AND PIPING SPECIFICATION MATRICES CONTAINED WITHIN THIS DRAWING SET. RESPONSIBILITY MATRIX EQUIPMENT FURNISH RECEIVE INSTALL WIRE START -UP DEMO OF EXISTING EQUIPMENT - - MC /EC - - WATER HEATER, PUMPS, SUPPLY FAN, MOTORS McK McK MC EC MC /CCN BOILER BURNER V V V EC V /CC GAS REGULATORS MC MC MC - MCN PIPING, VALVES, SENSOR WELLS, APPURTENANCES MC MC MC - MC DAMPERS, ACTUATORS CC CC CC /MC CC CC /MC COMBUSTION AIR DUCTING, FLUE DUCTING MC MC MC - MC MOTOR STARTERS MC MC EC EC EC CONTROL VALVES CC CC MC CC MC /CC INSULATION MC MC MC • . - - SENSORS CC CC CC CC CC FLOW METERS CC CC MC CC MC /CC WALL MODIFICATIONS GC GC GC - - LINE VOLTAGE WIRING EC EC • EC EC EC LOW VOLTAGE WIRING CC CC CC CC CC INTEGRATION WITH BAS CC CC CC CC CC COMMISSIONING/TESTING/BALANCING CA NOTES: GC - GENERAL CONTRACTOR CA - COMMISSIONING AGENT MC - MECHANICAL CONTRACTOR CC - CONTROLS CONTRACTOR McK - MCKINSTRY V - VENDOR EC - ELECTRICAL CONTRACTOR MECHANICAL BASIS OF DESIGN ITEM # SYSTEM CRITERIA CRITERIA SOURCE CODE BASIS FOR PROJECT , 1 -1 CODE 2009 INTERNATIONAL MECHANICAL CODE WITH WA STATE AMENDMENTS ' CITY OF TUKWILA 1 -2 CODE 2009 WASHINGTON STATE ENERGY CODE CITY OF TUKWILA 1 -3 CODE 2009 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS CITY OF TUKWILA 1-4 CODE 2009 INTERNATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS CITY OF TUKWILA 1-5 CODE 2009 INTERNATIONAL FUEL GAS CODE WITH WASHINGTON STATE AMENDMENTS CITY OF TUKWILA 1-6 CODE 2009 INTERNATIONAL PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS CITY OF TUKWILA 1 -7 CODE 2010 WASHINGTON STATE BOILER AND UNFIRED PRESSURE VESSLE CODE CITY OF TUKWILA LOAD BASIS FOR PROJECT 2 -1 OSA TEMP WINTER OSA DESIGN TEMP = 21 °F DB 2009 WSEC 2-2 INDOOR TEMP ' INDOOR HEATING DESIGN TEMP = 86 °F • DESIGN APPROACH 2 -3 OSA TEMP SUMMER OSA DESIGN TEMP = 79 °F DB 2009 WSEC BASIS FOR BUILDING ENVELOPE 3 -1 ROOF 1 MANUFACTURED CONCRETE PANELS (U- VALUE =0.1) CONFIRMED ON SITE 3 -2 WALL 1 8" CONCRETE BLOCK W/ 4" FACE BLOCK (U VALUE =0.07) CONFIRMED ON SITE 3-3 WINDOW 1 INSULATED GLASS (U-VALUE-1.04, SC -0.5) CONFIRMED ON SITE 3-4 FLOOR 1 POURED CONCRETE (U VALUE -0.1) CONFIRMED ON SITE BASIS FOR LOAD CALCULATIONS 4 -1 VENTILATION QUANTITIES MINIMUM OUTSIDE AIR VALUES BASED ON ASHRAE 62:1 REQUIREMENTS FOR POOLS AND SPECTATOR AREAS DESIGN APPROACH 4-2 INFILTRATION INFILTRATION RATE OF 0.5 ACH USED IN BUILDING LOAD CALCULATIONS DESIGN APPROACH • BASIS FOR GAS PIPING DESIGN 5 -1 GAS FIRED EQUIPMENT BOILER BURNER IS DERATED FROM 4405 CFH TO 4200 CFH TO MEET CONNECTED LOAD, BUILDING LOAD CALCULATIONS AND GAS METER CAPACITY. DESIGN APPROACH 5 -2 GAS METER GAS METER CAPACITY IS 4700 CFH AT 2 PSI. DESIGN APPROACH BASIS FOR MISCELLANEOUS ITEMS 6 -1 NATATORIUM SPACE PRESSURE NATATORIUM SPACE IS POSITLVELY PRESSURIZED WITH NO SOURCE OF POWERED RELIEF, RESULTING IN CONTAMINATION OF SURROUNDING SPACES WITH CHLORINATED AIR. RELIEF PATH IS VIA (4) LOUVERS IN EXTERIOR WALL. ADDITION OF A RELIEF FAN IS NOT INCLUDED IN THE SCOPE OF THIS PROJECT. CONFIRMED ON SITE 6-2 LOCKER ROOM HEATING WATER COIL LOCKER ROOM HEATING COIL LEAKS FROM PREVIOUS DAMAGE CONFIRMED ON SITE 6-3 ADA REQUIREMENTS ADA COMPLIANT PLUMBING FIXTURES ARE BEING INSTALLED. EXISTING ADA SPACES ARE NOT BEING UPGRADED TO FULL COMPLIANCE UNDER THIS SCOPE. DESIGN APPROACH 6-4 AIR HANDLER AIR HANDLER SUPPLY FAN IS BEING REPLACED. FAN IS SIZED TO MATCH AIRFLOW MEASUREMENTS OF 20,800 CFM TAKEN ON SITE AND MAINTAIN A MINIMUM OF 6 ACH. SPACE VOLUME OF 200,000 SQ FT REQUIRES A MINIMUM AIRFLOW OF 20,000 CFM TO MAINTAIN 6 ACH. DESIGN APPROACH 6 -5 DISCHARGE AIR TEMPERATURE AIR HANDLER CONTROLS SPECIFIED TO ACHIEVE 100F DISCHARGE AIR TEMPERATURE, DESIGN APPROACH 6-6 SEISMIC CONNECTION DETAILS ARE BASED ON A SEISMIC IMPORTANCE FACTOR OF 1.5 DESIGN APPROACH 6 -7 MECHANICAL ROOM EXHAUST THE MECHANICAL ROOM EXHAUST FAN IS DISABLED. MECHANICAL ROOM IS NOT BEING EXHAUSTED TO REMOVE CHLORINATED AIR. EQUIPMENT IN MECHANICAL SPACE .EXHIBITS SIGNS OF EXTENSIVE CORROSION. REPLACEMENT OF THE EXHAUST FAN IS NOT WITHIN THE BASE SCOPE OF THIS PROJECT. CONFIRMED ON SITE 6-8 FUEL SYSTEM BOILER WILL OPERATE ON NATURAL GAS. CONFIRMED ON SITE 6 -9 DOMESTIC WATER HEATER DOMESTIC WATER HEATER SIZING IS BASED ON FIXTURE COUNT AND FLOW RATES WITH A 640 GALLON PER HOUR RECOVERY RATE AT A WATER TEMPERATURE RISE OF 90F. DESIGN APPROACH 6 -10 LOCKER ROOM FANS THE SUPPLY AND EXHAUST FANS ARE CONSTANT VOLUME AND THE SYSTEM SUPPLIES 100% OUTSIDE AIR TO THE LOCKER ROOMS, LOBBY, FIRSTAID, JANITOR AND MANAGERS OFFICE. DESIGN APPROACH 6 -11 POOL FILL WATER METER WATER METER INSTALLATION DETAIL IS SHOWN WITH BY -PASS PIPING FOR MAINTENANCE OF THE METER. DESIGN APPROACH BASIS FOR HEATING SYSTEM DESIGN 7 -1 HEATING WATER PUMP PUMP SIZED TO MATCH EXISTING PUMP FLOW. EXISTING PUMP DIFFERENTIAL PRESSURE MEASURED AT 39.6 FT H20. PUMP HEAD CALCULATION PERFORMED TO VERIFY PUMP HEAD REQUIREMENTS. AVAILABLE PUMP HEAD HAS BEEN INCREASED FROM EXISTING EQUIPMENT. DESIGN APPROACH 7 -2 SYSTEM VOLUME BASED ON INFORMATION PROVIDED ON THE MECHANICAL PLANS DATED 6/29/1990. HEATING COIL VOLUMES NOT LISTED, VOLUMES CALCULATED USING 3RD PARTY SOFTWARE AND USED W SIZING OF EXPANSION TANK DESIGN APPROACH 7 -3 BOILER BURNER SIZING CRITERIA HEATING WATER PLANT SIZE IS BASED ON SPECIFIED HEATING WATER PUMP CAPACITIES AT 20° AT. (180 °F SUPPLY AND 160°F RETURN) DESIGN APPROACH 7-4 HEATING WATER SYSTEM HEATING WATER SYSTEM IS A VARIABLE FLOW CONFIGURATION WITH CONSTANT VOLUME PUMPS. PUMPS WILL RIDE THE PUMP CURVE TO MEET CHANGES IN DEMAND. DESIGN APPROACH 7 -5 FREEZE PROTECTION THE HEATING WATER LOOP CONSISTS OF 100% WATER WITH NO ADDITIVES FOR FREEZE PROTECTION. SEE CONTROLS SEQUENCE FOR FREEZE PROTECTION STRATEGY. PER OWNER 7-6 MINIMUM FLOW MINIMUM FLOW OF 57 GPM FOR THE BOILER IS BASED ON THE BURNER MINIMUM OUTPUT OF 570 MBH AT 206 AT PER OWNER 7 -7 BOILER SUPPLY TEMPERATURE 'THE BOILER DESIGN SUPPLY WATER TEMPERATURE IS 180 °F. PER OWNER BASIS FOR ADDITIONAL ALTERNATE ITEMS ' 8 -1 GENERAL "ADD ALTERNATE" ITEMS LISTED IN DRAWING SET ARE IDENTIFIED FOR BUDGETARY PRICING PURPOSES. MINIMAL ENGINEERING HAS BEEN DONE TO VERIFY FEASABLITY, ADDITIONAL DESIGN WILL BE REQUIRED IF THE MEASURES ARE ADOPTED AS PART OF THIS PROJECT PHASE. DESIGN APPROACH 8 2 GENERAL SUPPLY FAN IS SIZED FOR AN ADDITIONAL 1" W.C. EXTERNAL STATIC PRESSURE FOR FLEXIBILITY IN THE INSTALLATION OF FUTURE HEAT RECOVERY. ADDITIONAL MODIFICATIONS TO THE AIR HANDLING SYSTEM WILL BE REQUIRED IF HEAT RECOVERY IS TO BE IMPLEMENTED IN THE FUTURE. DESIGN APPROACH 8-3 GENERAL REFERENCE CONSULTANTS DRAWINGS FOR POOL RELATED CONTROLS AND EQUIPMENT. THESE ITEMS ARE NOT ADDRESSED IN THE MECHANICAL SCOPE. DESIGN APPROACH 8-4 GENERAL POTENTIAL LEAK IN HEATING WATER SYSTEM UNDER POOL DECK IS NOT BEING ADDRESSED IN THE SCOPE OF THIS PROJECT. DESIGN APPROACH ,..... ._!... _,.a, RECEIVED CITY OF TUKWILA OCT 10 2012 PERMIT CENTER P&telft,lect For Th instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1 -800 -669 -6223 PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 - 331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: (Th TRACK POOL MOMMENIMOMIIIMMEMEMINIME REVISIONS: 8/7/12 50% DD 9/4/12 75% CD'S 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31/12 AS SHOWN SHEET TITLE: GENERAL NOTES AND BASIS OF DESIGN SHEET NUMBER: M0.1 WOMEN' __LOCKER ROOM PIPES BELOW BLEACHERS BACK TO MECHANICAL ROOM SUPPLY DIFFUSER t=, ,._,: AT END OF BLEACHERS C STAINLESS STEEL PIPING CHASE EXISTING SUPPLY DIFFUSER ALONG WALL ABOVE BLEACHERS a STAFF ENTRY ATTENDANT 0.ERflL .\\\ 7.7-1777.1" 0 FIRST t;lU NATATORIUM, J RETURN GRILLE HIGH IN WALL --°' SUPPLY DUCT 11 II MCC :HANICAL Room LOCKER ROOM Q SUPPLY FAN OUTSIDE AIR INTAKE INS LOC KER __ROOM ELEC. ROOM 1 { N O'--O" L N 6O' -8" LOCKER ROOM® EXHAUST FAN 1 RELIEF LOUVERS (TYP. OF 4) FLOOR PLAN DEMO - MECHANICAL SCALE: 1/8" = 1'-0" 0 4' 8' 16' KEY NOTES O DEMOLISH SHOWER HEADS, VALVES AND APPURTENANCES. ® DEMOUSH LOCKER ROOM SUPPLY AND RETURN FAN MOTORS. ® DEMOUSH WATER CLOSETS, LAVATORIES, CARRIERS, LAVATORY TRAPS, AND ASSOCIATED APPURTENANCES. • DEMOUSH URINAL FLUSHOMETERS. O DEMOLISH SI1OWERHEADS, VALVES AND TOWER ASSEMBLIES. ® DEMOLISH THERMOSTATIC MIXING VALVES, RETAIN CABINET. 7Q DEMOLISH FAUCET. ` ® ADD ALTERNATE: DEMOUSH ISOLATION VALVES. CONFIRM QUANTITY AND IDENTIFY ADDITIONAL VALVES NOT SHOWN ON PLANS. • DEMOUSH THERMOSTAT. 04 DEMOLISH SHOWER PAN AND SURROUND. 11 ADD ALTERNATE: DEMOLISH HEATING COIL AND ASSOCIATED THERMOSTAT. 12 DEMOUSH HEATING COIL CONTROL VALVE. J RETURN GRILLE LOW IN WALL REVIEWED FOR CODE COMPLIANCE APPROVED NOV 082012 City of Tukwila BUILDING DIVISION STOP VALVES, P— TRAPS, CARRIERS PG1-1%- RECEIVED CITY OF TUKWILA OCT 1 0 2012 PERMIT CE1y-1° For Tft instry fe Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 -- 669 -6223 PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503- 331 -0234 www.mckinstry,com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: REVISIONS: 8/7/12 50% DD 914/12 75% CD'S 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS POOL TRACK NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31/12 AS SHOWN SHEET TITLE: FLOOR PLAN - MECHANICAL DEMO SHEET NUMBER: MD2.0 N 32' --0° N 447-0" N 60'_8r, PIPES BELOW BLEACHERS BACK TO MECHANICAL ROOM SUPPLY DIFFUSERS AT END OF BLEACHERS 1,1 STAINLESS STEEL PIPING CHASE SUPPLY DIFFUSER ALONG WALL ABOVE BLEACHERS WOMEN'S LOCKER ROOM ®3 SH -3, H -2 s d"- . -WC 1 _ 0§- __WC -2 O ---- WC -1'2 fJ� l.N . W.._., ......_- _.._.»...._- ........, -. ' ,E S STAFF .J® o E.IIT RY A l I EiNDANT M N') LOCK R MANAGER CONTROL FIRST AID M -1 LOCKER ROOM SUPPLY FAN MOTOR DRAGE & JANITOR c.,,, N 12' -0" ! O' -On ROOM LOCKER ROOM® RETURN FAN MOTOR M -2 ELEC. ROOM N 6O'• -8' NATATORIUM RELIEF LOUVERS (TYP OF 4) . FLOOR PLAN - MECHANICAL SCALE: 1/8" = 1'--0" o 4' 8'. 16' REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2012 City of Tukwila BUILDING DIVISION RETURN GRILLE HIGH IN WALL -- SUPPLY DUCT KEY NOTES M ECI1411 ,\L ROOM RETURN GRILLE LOW IN WALL 1 0 PROVIDE CONTROL VALVES FOR HEATING COILS. REFERENCE M7.2 FOR EQUIPMENT SCHEDULES. ® PROVIDE WATER CLOSETS, FLUSHOMETERS, LAVATORIES, STOP VALVES, CARRIERS, P -TRAPS AND FIXTURES. REFERENCE M7.0 FOR EQUIPMENT SCHEDULES. 3®. PROVIDE SHOWER HEADS, VALVES AND RISER FIXTURES. CLEAN OUT DRAIN LINES BACK TO THE NEXT ACCESSIBLE CLEAN OUT POINT. REFERENCE M7.0 FOR EQUIPMENT SCHEDULES. ® CONFIGURE MOTOR INSTALLATION TO ALLOW FOR SERVICING AND MAINTENANCE WITHOUT REMOVING SURROUNDING EQUIPMENT. PROVIDE ACCESS HATCH IN EXHAUST DUCT FOR BELT REPLACEMENT. PROVIDE MOTORS FOR SUPPLY AND RETURN FANS. REFERENCE M7.0 FOR EQUIPMENT SCHEDULES ®5 PROVIDE FLUSHOMEIERS. ® PROVIDE SPOOL PIECE AS REQUIRED TO CONNECT HOT WATER INLET TO HOT WATER OUTLET. CAP COLD WATER LINE. ®7 PROVIDE SHOWER HEADS AND VALVES. REFERENCE M7.0 FOR EQUIPMENT SCHEDULES. ® PROVIDE SHOWER PAN AND SURROUND. COORDINATE REQUIREMENTS WITH OWNER. 9® ADD ALTERNATE: PROVIDE HEATING WATER COIL AND TEMPERATURE SENSOR. 10 PROVIDE FAUCET. REFERENCE EQUIPMENT SCHEDULES ON M7.0 FOR DETAILS. 11 PROVIDE ISOLATION VALVES. CONFIRM QUANTITY AND SIZE: IDENTIFY ADDITIONAL VALVES NOT SHOWN ON PLANS. 12 PROVIDE ADDITIONAL HOLE IN SINK BASIN FOR MOUNTING FIXTURE. RECEIVED CITY OF TUKWILA OCT 10 2012 PERMIT CENTER pGP isct For Th instry fe Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800- 669 -6223 PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 -331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: POOL TRACK REVISIONS: 8/7/12 50% DD 9/4/12 75% CD'S 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31/12 AS SHOWN SHEET TITLE: FLOOR PLAN - MECHANICAL SHEET NUMBER: M2.0 0 w N O' -0s" 0 N E 2r —On N EF -1 MECHANICAL ROOM EXHAUST FAN /0 BOILER FLUE (2 -DOMESTIC WATER HEATER FLUE -- REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2012 Cit. Y of Tukwila BUILDING DIVISION N O' —On ROOF PLAN - MECHANICAL SCALE: 1/8" = 1' -0" 4' 8' 16' KEY NOTES 0 ADD ALTERNATE: REPLACE MECHANICAL ROOM EXHAUST FAN. U2 REFERENCE 3/M5.1 FOR DETAILS. . 1)&r).- gq RECEIVED CITY OF TUKWILA OCT 102012 PERMIT CENTER For Th instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 -669 -6223 PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503-331-0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: '■ TRACK POOL REVISIONS: 8/7/12 50% DD 9/4/12 75% CD'S 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31/12 AS SHOWN SHEET TITLE: • ROOF PLAN - MECHANICAL SHEET NUMBER: M2.1 DEMOLITION KEY NOTES • DEMOLISH DOMESTIC WATER HEATER, GAS PRV. PRV VENT LINES AND ASSOCIATED APPURTENANCES. ® DEMOLISH BOILER BURNER, GAS PRV AND ASSOCIATED APPURTENANCES. O OEMOUSH DOMESTIC HOT WATER RECIRCULATING PUMP. O DEMOLISH PIPE' SECTION FOR METER INSTALLATION. 0 DEMOLISH PIPE SECTION FOR AIR SEPARATOR INSTALLATION. ® DEMOLISH PUMP, TRIPLE DUTY VALVE AND APPURTENANCES. ED -0 STAIRCASE TO ABOVE.._ BOILER ---'' PH IIMitIE! .rLilI CHEMICAL T FEEDER 3/4" 6 "0 6 "0 FLUE UP FLOOR DRAIN 2" GAS FLOOR DRAIN CL tt 1/2" DIAMETER PVC CONDENSATE DRAIN SINK EXISTING ELECTRICAL PANELS (4) 24X30 WPL -1 (2) HIGH & LOW MOUNTED IN DOOR GAS LINE FROM METER BOILER ROOM MECHANICAL DEMO PLAN ea SALE: 1/4" = ,•-0 KEY NOTES 0 PROVIDE COMBUSTION AIR DUCT TO BOILER BURNER. PROVIDE BIRD SCREEN AND 90' TURN DOWN AT TERMINATION TO EXTERIOR. REFERENCE 4/M5.1 FOR DETAILS. ®2 ROUTE DUCT UP SIDE OF BUILDING TO ROOF. USE EXISTING ,PENETRATION IN WALL, SEAL AND WEATHERPROOF PENETRATION. PROVIDE RAIN CAP AT TERMINATION. REFERENCE 3/M5.1 FOR DETAILS. ® PROVIDE THERMOSTATIC MIXING VALVE. REFERENCE 2/M5.1 FOR DETAILS.. ® CORE WALL FOR COMBUSTION AIR DUCT PENETRATION. ' ®5 ADD ALTERNATE: BLANK OFF (2) UPPER LOUVERS IN DOOR. PAINT TO MATCH DOOR. (INCLUDE WITH MECHANICAL ROOM EXHAUST FAN ALTERNATE). ® PROVIDE WATER METER ON DRAIN LINE. REFERENCE 2/M5.0 FOR INSTALLATION DETAILS. ®7 REFERENCE 6/M5.0 FOR DETAILS. ® REFERENCE 7/M5.0 FOR PUMP INSTALLATION DETAILS. ® REFERENCE 3/M5.0 FOR GAS PIPING DIAGRAM. 10 PROVIDE BOILER BURNER AND PRV. REFERENCE EQUIPMENT SCHEDULES ON M7.0 AND M7.1. 11 ROUTE PRV VENT TO EXTERIOR, SIZE PIPE PER MANUFACTURERS RECOMMENDATIONS. REFERENCE 4 /M5.0 FOR DETAILS. WH REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2012 City of Tukwila BUILDING DIVISION STAIRCASE TO ABOVE- BOILER ✓' `/ BUCKET Z. FILTER 3/4" FLOOR DRAIN WATER HEATER FLUE VENT EXISTING ELECTRICAL PANELS 24X30 LOUVERS LOW MOUNTED IN DOOR ®5 FLOOR DRAIN 1/2" DIAMETER PVC CONDENSATE DRAIN ri CL BOILER ROOM MECHANICAL PLAN SCALE: 1/4" = 1' —O" 6" PVC COMBUSTION AIR DUCT GAS LINE FROM METER PGtoL 18q RECEIVED CITY OF TUKWILA OCT 1 0 2012 PERMIT CENTER For Th instry le Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 -669 -6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503- 331 -0234 www.mckinstry.com UNIIIMMEININIMMEMMI PROJECT: TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: TRACK POOL REVISIONS: 8/7/12 50% DD 9/4/12 75% CD'S 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: ENGINEERING DESIGNED BY:. DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31/12 AS SHOWN SHEET TITLE: ENLARGED BOILER ROOM MECHANICAL PLANS SHEET NUMBER: M3.0 2 -1/2" HS & HR UP 2"HWUP 3/4" HWC DN.—' 3 "CWUP 3" CW POOL FILL- 3" CW DN. -- --�'�� °WATER METER 1 ----- 3" CW CONN. f' .� TO EXISTING CW \ / I\ \ / 4" HWF \ HWR UP X / \ \'7,k1R DN. HS 2" CW DN. TO POOL MAKE -UP 2—WAY CONTROL° VALVE I 3—WAY I CONTROI L VALVE0 C 1 fff 2 -1/2" CW DN. 3/4" HWC DN. 2" HW DN. 4" HS DN. FILTER ROOM DEMO PLAN (1—.) KEY NOTES DEMOLITION O DEMOUSH WATER METER. ® DEMOLISH EXPANSION TANK. ® DEMOLISH CONTROL VALVES. EXPANSION TAN 2 -1/2" HS & HR UP 2" HW UP 1 3/4" HWC DN /' 1 3" CW UP 3" CW POOL Fl 3" CW DN «3" CW CONN. TO EXISTING CW 1%. / \ / 4" HS '\ / / HR UP N. X / \ / , HR\ \ f4 NUR DN. HS \ N. ICV -6I 2 —WAY O CONTROL VALVE 3 —WAY dfl -3>3 W "100d 0.1. 'ND MO 2 FILTER ROOM PLAN • SCALE: 1/4" 1' -O" KEY NOTES 2 -1/2" CW DN: 3/4" HWC DN. 2" HW DN. 4" HS DN. 0 PROVIDE POOL MAKE —UP WATER METER. PROVIDE INLET AND OUTLET STitA1GHT PIPE LENGTHS PER MANUFACTURERS RECOMMENDATIONS. REFERENCE 1/°15.0 FOR DETAILS. 0 PROVIDE EXPANSION TANK. REFERENCE 5A1.5.0 FOR DETAILS. 3° PROVIDE CONTROL VALVES. ET-1( RE ED FOR CODE COMPLIANCE APPROVED NOV 082012 City of Tukwila BUILDING DIVISION PL(A:-.109 RECEIVED CITY OF TUKWILA OCT 10 2012 PERMIT CENTER For Th instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503-331-0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: POOL REVISIONS: 8/7/12 50% DD 9/4/12 75% CD'S 9)26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING ARUSS MERRELL TIM WHITE SETH • DAVIS C10256 7/31/12 AS SHOWN SHEET TITLE: ENLARGED FILTER ROOM MECHANICAL PLANS SHEET NUMBER: M3.1 SUPPLY FAN z LADDER L. 1 1 RETURN D ABOVE -- AIR HANDLER MECHANICAL ROOM PLAN ELEVATION - DEMO • SCALE: 1/4" = 1'--0" FAN MECHANICAL ROOM ELEVATION - DEMO • SCALE: 1/4" = DEMOLITION KEY NOTES DEMOLISH SUPPLY FAN WITH INERTIA BASE, MOTOR AND SPRING ISOLATION. ADD ALTERNATE: DEMOUSH HEATING COIL AND ASSOCIATED BRANCH PIPING. DEMOUSH RETURN AIR CONTROL DAMPER IN DUCT BELOW. REMOVE PLENUM WALL AND ASSOCIATED ACCESS DOOR. RETAIN FOR REINSTALLATION. DEMOLISH OUTSIDE AIR CONTROL DAMPER, ACTUATORS AND ASSOCIATED PNEUMATICS. FLOOR GRID. TO BE REINSTALLED AFTER CONTROL DAMPER IS INSTALLED. DEMOUSH RETURN AR CONTROL DAMPER AND ACTUATOR IN RETURN AIR DUCT ABOVE PNEUMATICS REMOVE 36W1X22"H AND ASSOCIATED OUTSIDE AIR LOWER 48"W x 50"H DUCT CONNECTION 1 LADDER RETURN ABOVE r7 1 1 1 0 RETURN DUCT 864W x 6611 BELOW DUCT CONNECTION TO COIL LJ 0 2 AIR HANDLER MECHANICAL ROOM PLAN SCALE: 1/4" = 11--0" srEEL BAR FLOOR FAN MECHANICAL ROOM ELEVATION • SCALE: 1/4" = 1' -0" KEY NOTES O MOUNT SUPPLY FAN AND MOTOR ON INERTIA BASE WI1H SPRING ISOLATION (FURNISHED WUH SUPPLY FAN). CONTRACTOR TO CONFIRM POSITIVE CONNECTION MD NOTIFY STRUCTURAL ENG!NEER.L ® FLEXIBLE DUCT CONNECTION. ® NOT USED. ® BASE SCOPE CLEAN AND FLUSH AR/WATER SIDES OF EXISTING HEATING COIL ADD ALTERNATE PROVIDE HEATING COIL CONNECT TO EXISTING BRANCH PIPING. ® PROVIDE 1WO 461X82"H HI —PRO POLYESTER COATED CONTROL DAMPERS. • REINSTALL ACCESS DOOR. ✓ PRC IDE 381WX2611 HI —PRO POLYESTER COATED CONTROL DAMPER. ® REINSTALL PLENUM WW1. 09 PROVIDE 721X22"H H1 —PRO POLYESTER COATED CONTROL DAMPER ABOVE. OUTSIDE AIR DAMPER SHEET NOTES . REFERENCE CONTROLS DIAGRAMS ON M6.0 FOR ADDITIONAL. INFORMATION. ▪ REMOVE HEATING COIL, FILTER BANK, AIR KANDLER CABINET AND OUTSIDE AIR LOWER AS NECESSARY TO REMOVE AND REPLACE SUPPLY FAN THROUGH OUTSIDE AIR OPENING. RETAIN PARTS FOR REINSTALLATION, REPLACE OBIS DAMAGED DURING REMOVAL 3. DEMOLISH ABANDONED PNEUMATIC LINES. 4. INSTALLED EQUIPMENT AND MATERIALS TO BE CORROSION RESISTANT, SUffABLE FOR USE WDH A CHLORINATED ENVIRONMENT. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2012 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 10 2012 PERMIT CENTER • For Th instry life Of Your Building • SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 INMENN PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 -331 -0234 www.mokinstty.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: POOL REVISIONS: 8/7/12 50% DD 9/4/12 75% CD'S 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENLARGED AIR HANDLER MECHANICAL ROOM PLANS ENGINEERING ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31/12 AS SHOWN SHEET NUMBER: M3.2 GAS SUPPLY GAS SHUT —OFF VALVE DIRT LEG DWH -1 GAS WATER HEATER (140T) FLUE SEE HVAC PLANS FOR SIZE AND ROUTING T & P RELIEF VALVE (TYP) 2" THERMOSTATIC MIXING VALVE BOD: LEONARD 1M- 830 —RF /TC SHUT —OFF VALVE (TYP.) 3/4" NION (TYP) F- r ECK VALVE (TYP) ST -1 STORAGE TANK (140`F) " HOSE END DRAIN VALVE (TYP) FLOOR CONDENSATE DRAIN, ROUTE TO NEAREST FLOOR DRAIN NOTES: 1. SEE PLANS OR RISER FOR PIPE SIZES. 2. T &P VALVES FURNISHED WITH TANKS. 3. REFERENCE 1/M5.2 FOR CONNECTION DETAILS. ROUTE T &P RELIEF DRAINS TO NEAREST FLOOR DRAIN GAS WATER HEATER STORAGE TANK CONNECTION DETAIL SCALE: NOT TO SCALE PVC VENT PIPE SEE EQUIPMENT SCHEDULE FOR VENT DIAMETER LISTED "BIRD — PROOF" VENT CAP VENT CAP HEIGHT BRACE VENT. TO STRUCTURE ROOF STRUCTURE (TIP) EXTERIOR WALL NOTES: 1. VENT CONE HEIGHT TO BE A MINIMUM OF 3' -0" ABOVE ROOF LINE AND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING WITHIN 10'. 2. REFER TO MANUFACTURERS INSTRUCTIONS AND IFGC 503.6.4 "GAS VENT TERMINATION" FOR ADDITIONAL REQUIREMENTS. 3. VENT CONE HEIGHT TO BE • A MINIMUM OF 4' —O" ABOVE COMBUSTION AIR INTAKES. � 3 TYPICAL VENT DISCHARGE DETAIL — J NOT TO SCALE DRAIN PAN 4 COLD WATER 2 HOT WATER 2" Iq S HOT WATER RECIRC. 1 \--3/4" EXPANSION TANK EXTERIOR WALL WEATHERPROOF GAP BETWEEN DUCT AND WALL. PROVIDE 90' TURNDOWN WITH BIRD SCREEN AT TERMINATION OF COMBUSTION AIR DUCT 1 HOT WATER SOURCE J. COLD SUPPLY II I HOT WATER TO FIXTURES 2" 1 BALL VALVE FOR SETUP HOT WATER RECIRC I r TEMPERED CIRCULATOR KEY NOTES 01 FURNISH WITH TEST CONNECTION FOR SETUP. O REFERENCE MANUFACTURERS LITERATURE FOR BALANCING AND SETUP REQUIREMENTS. INITIAL SUPPLY WATER SET POINT TO BE 120'F. AQUASTAT HEAT TRAP CHECK VALVE CHECK VALVE V�......wr....rrr...r w .nom. BALANCING VALVE 3/4" ISOLATION VALVE 3/4" J. TEMPERED RETURN THERMOSTATIC MIXING VALVE INSTALLATION DETAIL SCALE: NOT TO SCALE SEE M3.0 FOR LOCATION AND SIZE. TYPICAL COMBUSTION AIR DETAIL NOT TO SCALE 1)G REVIEWED FOR CODE COMPLIANCE APPROVED NOV 082012 City of Tukwila BUILDING DIVISION '39 RECEIVED CITY OF TUKWILA OCT 10 2012 PERMIT CENTER For Th instry fe Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 -669 -6223 PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 -331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: POOL TRACK REVISIONS: 8/7/12 50% DD 9/4/12 75% CD'S 9126/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31/12 AS SHOWN MECHANICAL DETAILS SHEET NUMBER: M5.1 EDGE OF HOUSEKEEPING PAD HSS 5x3x3/16 TYP UNO 43x3x3/16x0' -3" HSS TO HSS (TYP) 1 w N 41 PLAN fR 1 1 V 1 -1/2" WIDE x 16 ga BENT STRAP (TYP) HSS 5x3 AT TOP OF FRAME CAP R WITH SEAL WELD TOP AND BOTTOM. (TYP.) 2" MIN. <TYP SHARP TO 1455 ] 2" MIN. HORIZONTAL HSS PER PLAN (TYP) (ALIGN W /STRAPS) STRAP PER PLAN (TYP) HOT WATER HEATER BY OTHERS VERT HSS PER PLAN 2" MIN.r 12" MIN. 4 PER PLAN (TYP) HOUSEKEEPING PAD ELEVATION REM 1. SPECIAL INSPECTION REQUIRED PER IBC CHAPTER 17. 2. t =GAUGE OF MATERIAL. � WATER HEATER ATTACHMENT DETAIL NOT TO SCALE PROVIDE (4) 1/2" 0 HILTI TZ EXPANSION ANCHORS W/3 -1/4" EMBEDMENT ANCHORAGE SCHEDULE TAG HIM TZ ANCHOR EMBEDMENT NEOPRENE PAD & HG BUSHING COMMENTS PUMPS: P -1 CS 1/2" 0 3 --1/4" MASON SUPER W HG-50 40 FT EQUIPMENT LEG BASE RAIL OR FACTORY CURB HOUSEKEEPING PAD TOC NEOPRENE ISOLATION PER SCHEDULE CONCRETE SLAB KEY NOTES: O PROVIDE MASON TYPE HGV -50 BUSHING MASON SUPER W PADS 0 PROVIDE CONNECTION AT EA CORNER TYP, UNO CONCRETE ANCHOR PER SCHEDULE SEISMIC ATTACHMENT DETAIL NOT TO SCALE TOLCO FIG 909 1" PIPE ONLY TOLCO FIG 980 1" THRU 2" IPPE. OR 12 GA CHANNEL EA END LONGITUDINAL BRACE AND CONNECTION TO STRUCTURE ARE SIMILAR TO TRANSVERSE BRACES BRACE PER TABLE 1 ALTERNATE BRACE UTILIZE FIG 216, TOLCO FIG 4A IF TRANSVERSE BRACE IS NOT LOCATED AT GRAVITY HANGER STRUCTURE - PROVIDE HILTI J " DIA 12 ANCHOR W/ 3 -1/4" EMBED (MIN.) SINGLE PIPE TRANSVERSE USING PIPE BRACING ELEVATION DETAIL STRUCTURE - PROVIDE HIL11 )" DIA 12 ANCHOR W/ 3 -1/4" EMBED (MIN.) ti TYPICAL PIPE TO HANGER ATTACHMENT. UTILIZE STRUT MANF CLAMP OR BENT ROD WW MSS SP -58 -2009 45 45 f15 » SINGLE PIPE LINGITUDINAL USING PIPE BRACING SECTION DETAIL LONGITUDINAL BRACE AND CONNECTION TO STRUCTURE ARE SIMILAR TO TRANSVERSE BRACES. LONGITUDINAL BRACE SHALL UTILIZE TOLCO FIG 4L OR TOLCO FIG 4A WITH FIG 980. FOR COPPER TUBE UTILIZE COOPER B -LINE 83373CT AS LONGITUDINAL BRACE. PIPE OD CONDUIT RIGID BRACING SEISMIC DETAIL NOT TO SCALE PANSION TANK CONCRETE HOUSEKEEPING PAD KEY NOTE: 0 SEE 4/M5.2 FOR ADDED INFO. PROVIDE (1) CONCRETE ANCHOR AT EA ANGLE (3) LOCATIONS MIN TYP. TYPICAL EXPANSION TANK PARTIAL PLAN NOT TO SCALE ALLOWABLE BRACE LOADS mammy Rim BRACE M✓�� WEIGHT PER FT AT BRACE SPACING (LB /F1') A B SESMIC ROD CLAMP SPACING 10 FT 20 FT 30 FT 40 FT LOCAl1ON MPRB -r p SCH 40 1" w 7 FT • . 46.5 23.2 15.4 11.6 1/2" 12" MPRB 1.5" P SCH 40 1.5" 10 FT 74.8 37.4 24.9 18.7 1/2" 12" 1. USE 12 GA GALVANIED OR CADNIUM•PLATED STRUT 2. THE LB /FT VALUES INDICATED IN TABLE ARE DERIVED USING FPH =1.0. THE LB /FT VALUE MAY BE MODIFIED Ui1UZING THE TRUE ACCELERATION VALUE OBTAINED FROM THE MECHANICAL SEISMIC DESIGN SHEET. VALUES ARE MODIFIED AS FOLLOWS: (1 /FPH, ACTUAL) *(LB /FT)= ALLOWABLE BRACE LB /FT. 3. COMPONENT SIZES CALCULATED USING ALLOWABLE STREET DESIGN (ASD). 4. LOADS MUST BE PRESENTED TO SER FOR REVIEW. GENERAL NOTES: 1. DO NOT MIX RIGID BRACING WITH CABLE BRACING IN THE SAME DIRECTION ON ANY PIPE RUN UNTIL AFTER A CHANGE IN DIRECTION AT AN ELBOW. 2. PIPING SHALL BE HUNG AT MAXIMUM GRAVITY HANGER INTERVALS AS OUTLINED IN 2009 IMC, 2009 IFGC, OR MSS SP-69. 3. BRACE SPACING AND TRAPEZE SUPPORT ANGLE SHALL BE SELECTED UTILIZING THE "MCKINSTRY PIPE HANGING AND BRACING' CALCULATOR. 4. BRACE DESIGN SHALL BE CONSISTENT WITH THE METHODS OUTLINED IN THE "MCKINSTRY PIPE BRACING LAYOUT PROCEDURE'. 5. DO NOT USE RIGID BRACING FOR VIBRATION ISOLATED PIPING. SEE CABLE BRACE DETAIL IF VIBRATION ISOLATION IS REQUIRED. 6. DESIGN IN ACCORDANCE WM-I 2009 IBC AND ASCE <7 -05 CRITERIA. 7. DETAIL IS DESIGNED TO ACCOMMODATE PIPING, PLUMBING, OR ELECTRICAL CONDUIT. 8. WHEN LARGE PIPE REQUIRES BRACING, PLEASE SEE MCKINSTRY ENGINEERING FOR APPLICABLE DETAILS. 9. ATTACH TO EXISTING UNISTRUT, CONTRACTOR TO COORDINATE. 10. SEE STRUCTURAL ENGINEER IF CONNECTION DEVIATES FROM DETAIL REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2012 City of Tukwila BUILDING DIVISION 1/2 "0 HILTI TZ ANCHOR HOUSEKEEPING PAD CONCRETE SLAB L3X3X3/16 X O' -3 ", FIT FLUSH AGAINST WALL OF TANK RECEIVED CITY OF TUKWILA OCT 1 0 2012 PERMIT CENTER CO EXPANSION TANK ANCHORAGE & SEISMIC DETAIL NOT TO SCALE instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 -669 -6223 PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 -331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: TRACK POOL EXPIRES 9-23-2014 REVISIONS: 8/7/12 50% DO 9/4/12 75% CD'S 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31 /12 AS SHOWN SHEET TITLE: EQUIPMENT CONNECTION DETAILS SHEET NUMBER: M5.2 EXPANSION TANK /- low PNEUMATIC VALVE PRV ASSEMBLY ® i 4" P -2 1 11 POOL HEAT EXCHANGER 4" HC-6 POOL AHU ,(COIL 3/4" 3/4" 3/4.. HC--5. ill LLOBBY �J LAID J f r i HC-4 r 1 HC -2 3/4" HC -3 11 REDUCED PRESSURE BACKFLOW PREVENTER L NPCW (Th\HEATING WATER PIPING DIAGRAM - DEMO _} NOT TO SCALE NATATORIUM SPACE TUKWILA POOL SEQUENCE OF OPERATIONS THE PURPOSE OF THIS DOCUMENT IS TO DESCRIBE THE SEQUENCE OF OPERATIONS FOR THE CONTROL SYSTEM. THE CONTROLS CONTRACTOR SHALL PROVIDE CONTROL DEVICES, WIRING, PROGRAMMING AND APPURTENANCES NECESSARY TO PROVIDE A CONTROL SYSTEM TO EXECUTE THE INTENT DESCRIBED. THE SEQUENCE OF OPERATIONS IS NOT A PROGRAMMING GUIDE. THE CONTROLS CONTRACTOR IS RESPONSIBLE FOR THE FUNCTION OF THE SYSTEMS AND PROGRAM MING REQUIRED IN ORDER TO ACHIEVE FULLY FUNCTIONAL OPTIM IZED SYSTEMS. THE FRONT END CONTROLS TERMINAL SHALL BE PROGRAMMED TO SHOW MONITORED CONTROL POINTS ASSOCIATED WITH THE HEATING WATER AND AIRSIDE SYSTEMS. 1. GENERAL 1:1. THE BURNER CONTROL PANEL ASSOCIATED WITH THE BOILER SHALL CONTROL AND MONITOR THE BOILER OPERATION. REFERENCE MANUFACTURER LITERATURE FOR DETAILS OF OPERATION AND INSTALLATION. 1.2. THE BUILDING AUTOMATION SYSTEM (BAS) ENABLES AND MONITORS THE BURNER CONTROL PANEL, AIR HANDLER SUPPLY FAN AND HEATING WATER PUMPS. 1.3. SET POINTS AND VALUES INDICATED SHALL BE GRAPHICALLY ADJUSTABLE VIA THE OPERATOR WORKSTATION. 1.4. THE SPACE TEMPERATURE SET POINT SHALL BE 86 °F. 1.5. THE INITIAL LOCKER ROOM OUTSIDE AIR PRE -HEAT COIL DISCHARGE AIR TEMPERATURE SET POINT SHALL BE 90 °F. . 1,5.1.ADDITIONAL COIL INITIAL DISCHARGE AIR TEMPERATURE SET POINTS SHALL BE 90 °F. 1.6. PROVIDE TUNING AS REQUIRED TO OPTIMIZE SYSTEM PERFORMANCE. 1.7. THE CONTROLS CONTRACTOR SHALL BE RESPONSIBLE FOR THE FOLLOWING: 1.7.1. GENERATING THE SEQUENCE OF OPERATION. 1.7.2. GENERATING THE CONTROL DIAGRAM COMPLETE WITH SYSTEM CONTROLS COMPONENTS. 1.7.3. TESTING AND VERIFICATION OF THE SEQUENCE OF OPERATION BEFORE FUNCTIONAL TESTING WITH THE COMMISSIONING AGENT. 17.4. PERFORMING FUNCTIONAL PERFORMANCE TESTING WITH THE COMMISSIONING AGENT. 1.8. THE MECHANICAL CONTRACTOR SHALL PROVIDE INITIAL BOILER SETUP. 1.9, THE CONTROLS CONTRACTOR SHALL PROVIDE BAS CONNECTION TO BOILER BURNER. 1.10. CONTROLS CONTRACTOR TO SUBMIT DRAWINGS AND SEQUENCE OF OPERATION TO COM M ISSIONING AGENT AND MCKINSTRY FOR APPROVAL PRIOR TO INSTALLATION AND PROGRAMMING. 1.11. CONTROLS CONTRACTOR SHALL REFERENCE MCKINSTRY CONTROL PROVIDER PERFORMANCE STANDARD FOR PROJECT EXPECTATIONS AND WORK WITH COMMISSIONING AGENT FOR ADHERENCE. 1..12. OPERATE HEATING WATER SYSTEM PER EXISTING SEQUENCE FOR ITEMS NOT SPECIFICALLY ADDRESSED BELOW. 2. SET POINTADJUSTMENT 2.1: A WARNING SCREEN SHALL BE GENERATED EACH TIME AN ADJUSTABLE SET POINT IS MODIFIED. THE WARNING SHALL READ "MODIFICATIONS OF THIS VALUE MAY ALTER SYSTEM ENERGY PERFORMANCE." 2.2. THE SYSTEM SHALL OFFER THE USER THE OPTION OF "PERMANENT VALUE ADJUSTM ENT" OR "TEMPORARY VALUE ADJUSTMENT." 2.2.1.AT THE END OF EACH DAY, ALL "TEMPORARY VALUE ADJUSTMENT" INPUTS SHALL REVERT TO LAST "PERMANENT VALUE" INPUT. IF THERE ARE NO "PERMANENT VALUE" INPUTS, THEN REFERENCE DEFAULT VALUE USED IN INITIAL PROGRAMMING. 2.3. A LOG SHALL BE MAINTAINED THAT CATALOGS ANY SET POINT VALUE THAT HAS BEEN ADJUSTED. AT A MINIMUM, THE LOG SHALL CAPTURE: 2.3.1.USER ID, TIME OF DAY, AND DATE. 2.3.2.SET POINT THAT WAS MODIFIED. 2.3.3.SELECTION OF "PERMANENT" OR "TEMPORARY" VALUE ADJUSTMENT. 2.3.4.LAST "PERMANENT INPUT" VALUE OF SET POINT PRIOR TO CHANGE. 2.4. SET POINT ADJUSTED VALUE. 3. BOILER BURNER CONTROL PANEL 3.1. ENABLE AND DISABLE BURNER CONTROL PANEL THROUGH THE BAS SYSTEM. THIS COMMAND SHALL BE HARDWIRED TO THE BURNER. 3,2. THE BOILER SUPPLY TEMPERATURE SET POINT SHALL REMAIN AS EXISTING. 3.3. PROVIDE OFFSETS, DEAD BANDS, TIME DELAYS AND SAFETIES FOR FULLY FUNCTIONAL AND/OPTIMIZED SYSTEM THAT LIMITS SHORT CYCLING. 3.4. WHEN THE HEATING WATER SYSTEM IS ENABLED THE BURNER SHALL OPERATE TO MAINTAIN THE BOILER LEAVING WATER SUPPLY SET POINT. 4. HEATING WATER SYSTEM 4.1. THE HEATING WATER SYSTEM COMPONENTS SHALL BE ENABLED IF THERE IS A CALL FOR SPACE HEATING OR LOCKER ROOMS OSA 4 ong PNEUMATIC VALVE HC -1 i Ii Q OSA DEMOLITION KEY NOTES O ADD ALTERNATE: DEMOUSH HEATING COIL. 0 DEMOLISH PIPE SECTION FOR MR SEPARATOR INSTALLATION. 00 ADD ALTERNATE: DEMOUSH POOL AHU COIL. ® DEMOLISH PNEUMATIC VALVES. ... �' BAS SPACE SPACE >7-0, <SA< SPACE SPACE EXPANSION TANK P -9 BOILER N„, 'y BAS OUTSIDE OUTSIDE BAS 1 �-- POT ' FEEDER TO POOL 6 FROM V 1 POOL P -5 ` r- AS -1 I2 \ ®' ® P--2) 1 4.. POOL HEAT EXCHANGER 1 1 ..= ...- J 1 �.r .rte " 1 I �• 1 ■ 1 1 /♦ 1 / 4" `w %% 1 1 / /i , 4 HC -6 POOL j j 3 COIL i i ! 1 --- -x--11 s ( � 3/4" of � 11 ---- bNO PRV ASSEMBLY `I BAS I .MMM • MOM. HC -6 1 BAS r HWR HWS AIR HANDLER ROOM r J LFILTER ROOM r [BOILER ROOM NATAORIUM AIR HANDLING UNIT SYSTEM DIAGRAM NOT TO SC THE POOL IS CALLING FOR HEAT. 4.1.1. POOL TEMPERATURE SENSOR TO PROVIDE SIGNAL TO GAS. 4.2. THE BAS SHALL ENABLE/DISABLE THE HEATING WATER PUMP ON A CALL FOR HEATING FROM ANY ZONE. 4.3. RESET THE SUPPLY WATER TEMPERATURE TO THE HEATING COILS BASED ON DEMAND. 4.3.1. MODULATE THE 3 -WAY MIXING VALVE FOR THE HEATING WATER LOOP (CV -7) TO MAINTAIN THE SUPPLY WATER TEMPERATURE SET POINT. 4.4. ON A CALL FOR HEATING, MODULATE THE HEATING WATER VALVE FOR THE RESPECTIVE ZONE TO MAINTAIN THE SPACE TEMPERATURE. 4.5. A SUMMARY OF THE HEATING WATER VALVE POSITIONS ASSOCIATED WITH THE HEATING COILS SHALL BE GENERATED BY THE BAS EVERY 5 MINUTES. UPON DAILY START THE VALVE POSITION WILL NOT BE POLLED UNTIL THE FIRST 15 MINUTES OF OPERATION HAS BEEN COMPLETED. 4.6. WHEN THE MOST OPEN VALVE IS GREATER THAN 90% OPEN, RAISE THE SUPPLY HEATING WATER SET POINT BY TWO DEGREES. 4.7. WHEN THE MOST OPEN VALVE IS LESS THAN 75% OPEN LOWER THE SUPPLY HEATING WATER SET POINT TWO DEGREES. 4.7.1.PROVIDE THE ABILITY TO INCLUDE /EXCLUDE ZONES USED IN POLLING AT THE OPERATOR WORKSTATION. 4.8. THE MAXIMUM VALUE OF THE HEATING WATER SUPPLY TEMPERATURE RESET SHALL BE 180 DEGREES F. 4.9. THE MINIMUM VALUE OF THE HEATING WATER SUPPLY TEMPERATURE RESET SHALL BE 160 DEGREES F. 4.10. CONTINUE TO OPERATE THE HEATING WATER PUMP FOR 5 MINUTES AFTER THE BOILER HAS BEEN DISABLED. 4.11. IF THE BOILER RETURN WATER TEMPERATURE FALLS BELOW 140 °F OPERATE THE BOILER PUMP (P -9) TO MAINTAIN A MINIMUM RETURN WATER TEMPERATURE TO THE BOILER OF 150 °F. 6. PRIMARY SUPPLY FAN 5.1. THE AIR HANDLER SUPPLY FAN SHALL BE ENABLED AND DISABLED VIA THE OPERATOR WORKSTATION. 5.1.1.THE SUPPLY FAN VFD SHALL BE USED TO BALANCE THE SYSTEM. 5.1.2.THE SUPPLY FAN OPERATES CONTINUOUSLY. 5.2. ON A CALL FOR SPACE HEATING THE HEATING WATER COIL ASSOCIATED WITH THE PRIMARY AIR HANDLER SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE. 5,2.1.THE SPACE TEMPERATURE SHALL BE THE AVERAGE OF THE TWO SENSORS IN THE SPACE. 5.3. THE OUTSIDE AIR DAMPERS AND RETURN AIR DAMPERS SHALL MODULATE TO MAINTAIN AN AVERAGE RELATIVE HUMIDITY BETWEEN 40% AND 60% IN THE NATATORIUM. 5.3.1. NATATORIUM HUMIDITY VALUE SHALL BE THE AVERAGE OF THE TWO SENSORS IN THE SPACE. 5.3.2. MAINTAIN A MINIMUM OUTSIDE AIR REQUIREMENT OF 5,600 CFM DURING OCCUPIED HOURS. 5.3.3. MAINTAIN A MINIMUM OUTSIDE AIR REQUIREMENT OF 0 CFM DURING UNOCCUPIED HOURS. 5.4. ON A CALL FOR COOLING, ENABLE ECONOMIZER COOLING IF THE OUTSIDE AIR TEMPERATURE IS LESS THAN THE SPACE TEMPERATURE AND THE SPACE TEMPERATURE IS GREATER THAN 86 °F. 5.4.1 MODULATE THE OUTSIDE AIR DAMPER AND RETURN AIR DAMPERS IN SEQUENCE TO PROVIDE ECONOMIZER COOLING WHILE MAINTAINING THE SPACE HUMIDITY REQUIREMENTS. 5.5 THE OUTSIDE AIR DAMPER POSITIONS SHALL BE FIELD DETERMINED BY THE TAB AGENT BASED ON MAINTAINING THE MINIMUM OUTSIDE AIRFLOWS. LOCKER ROOM SUPPLY AND EXHAUST FAN SYSTEM 6.1. THE SUPPLY AND EXHAUST FANS SHALL BE ENABLED AND DISABLED VIA THE BAS. 6.2. OPERATE THE FANS DURING OCCUPIED HOURS. 6.2.1.ON A CALL FOR HEATING DURING UNOCCUPIED HOURS, ENABLE THE FANS AND MODULATE THE RESPECTIVE HEATING WATER COIL VALVE TO MAINTAIN THE SPACE TEMPERATURE. 6.2.2.CLOSE THE OUTSIDE AIR DAMPER WHEN THE FANS ARE DISABLED. 7. FREEZE PROTECTION 7.1. IF THE FREEZE STAT FOR SF -1 IS TRIGGERED, SHUTDOWN THE SUPPLY FAN AND CLOSE THE OUTSIDE AIR DAMPER. 7.2. IF THE FREEZE STAT FOR THE LOCKER ROOM FAN IS TRIGGERED, SHUT DOWN THE SUPPLY AND EXHAUST FANS AND CLOSE THE OUTSIDE AIR DAMPER. 8. DOMESTIC HOT WATER SYSTEM 8.1 THE DOMESTIC WATER HEATER SHALL BE ENABLED AND DISABLED VIA THE BAS.. 8.2 OPERATE THE SHUTTLE PUMP (P -4) TO MAINTAIN A WATER TEMPERATURE OF 140 °F IN THE STORAGE TANK (ST- 1). 8.3 OPERATE THE DOMESTIC HOT WATER RECIRCULATION PUMP (P-3) VIA THE INTERNAL CONTROLS TO MAINTAIN A TEMPERATURE AT THE PUMP OF 100 °F DURING OCCUPIED HOURS. 9. BAS INTERFACE WITH THE HEATING WATER SYSTEM 9.1 PROVIDE: HARDWARE AND SOFTWARE REQUIRED TO ALLOW THE BAS SYSTEM TO INTERFACE WITH THE CONTROLLED EQUIPMENT. COORDINATE REQUIREMENTS WITH THE EQUIPMENT MANUFACTURER FOR THE REDUCED PRESSURE BACKFLOW PREVENTER L 3/4" of T -- 3/4" _ 3/4" 01 LBATijPOM OJ LBBY 1� CV-5I C NO NPCW 1 fir^ I.1 r LOCKER ROOMS r 1.4 BAS {7__ 1 / 1 OSA /1 0r �. ' .00 HEATING WATER PIPING DIAGRAM NOT TO SCALE KEY NOTES ® ADD ALTERNATE: PROVIDE HOT WATER COIL FOR LOCKER ROOMS. ® PROVIDE AIR SEPARATOR. REFERENCE 6/M5.0 FOR CONNECTION DETAILS. ® ADD ALTERNATE:. PROVIDE HOT WATER COIL FOR AIR HANDLER. ® FURNISH CONTROL VALVES (BY C.C.). INSTALLED BY MECHANICAL CONTRACTOR. ®5 PROVIDE EXPANSION TANK. REFERENCE 5/M5.0 FOR DETAILS. ® ADD ALTERNATE: PROVIDE MECHANICAL ROOM EXHAUST FAN AND TEMPERATURE SENSOR. CONNECT TO BAS. REFERENCE POOL SCOPE DOCUMENTS FOR PUMP INFORMATION: ® ADD ALTERNATE: PROVIDE HOT WATER COIL. O. PROVIDE HUMIDITY SENSORS WITH A RELATIVE HUMIDITY RANGE OF 20% --95X. 10 LOCATE VALVES FOR SYSTEM PRESSURE TESTING JUST INSIDE MECHANICAL ROOM. 11 REFERENCE ELECTRICAL. DRAWINGS FOR SUPPLY FAN INTEGRATION WITH THE SMOKE AND FIRE DETECTION SYSTEM. 12 HARD WIRE FREEZE STAT TO SHUT DOWN SUPPLY FAN. 13 USE AVERAGE OF' BOTH SENSORS FOR TEMPERATURE AND HUMIDITY CONTROL 14 HARD WIRE FREEZE STAT TO SHUT DOWN SUPPLY AND EXHAUST FANS. OSA INTERFACE. THE BAS SYSTEM SHALL SPECIFICALLY MONITOR OR PROVIDE THE FOLLOWING: 9.1.1 BOILER ENTERING AND LEAVING WATER TEMPERATURES 9.1.2 PRIMARY LOOP SUPPLY WATER TEMPERATURE 9.1.3 PRIMARY LOOP RETURN WATER TEMPERATURE 9,1.4 SECONDARY LOOP SUPPLY WATER TEMPERATURE 9.1.5 BOILER START /STOP COMMAND 9.1.6 BOILER BURNER FIRING RATE 9.1.7 HEATING WATER SUPPLY TEMPERATURE SET POINT 9.1.8 BOILER BURNER STATUS 9.1.9 BOILER BURNER ALARM STATUS 9.1.10 BOILER BURNER ENABLE/DISABLE 9.1.11 HEATING WATER PUMP COMMAND 9.1.12 HEATING WATER PUMP STATUS 9.1.13 SUPPLY FAN MOTOR STATUS 10 ALARMING 10.1 ALARMS SHALL BE MONITORED AND CONTROLLED PER THE OWNERS STANDARDS. ADDITIONAL ALARMS ADDED PER OWNER REQUIREMENTS. , 10.2 ALARMS SHALL BE ADDED TO THE ALARMS GRAPHICS SUMMARY PAGE(S) IN THE BAS. 10.3 "BOILER SHORT CYCLING ": GENERATE AN ALARM WHEN ANY BOILER IS COMMANDED TO STOP AND START MORE THAN FIVE TIMES OVER A TIME PERIOD OF ONE HOUR. 10.4 "BOILER FAILURE ": GENERATE AN ALARM WHEN THE BOILER BURNER COMMAND DOES NOT MATCH'THE BOILER BURNER STATUS. A TIME DELAY SHALL BE OBSERVED AFTER A CHANGE IN COMMAND TO ALLOW EQUIPMENT START -UP OR SHUT DOWN. 10.5 "DISCHARGE AIR TEMPERATURE OUT OF RANGE ": GENERATE AN ALARM WHEN THE DISCHARGE AIR TEMPERATURE FALLS BELOW THE FREEZE PROTECTION LOW LIMIT ABOVE 10.6 "VALVE FAILURE ": GENERATE AN ALARM IF THE STATUS OF A CONTROL VALVE POSITION DOES NOT MATCH THE COMMANDED POSITION. 10.7 "DAMPER FAILURE ": GENERATE AN ALARM IF THE STATUS OF A DAMPER POSITION DOES NOT MATCH THE COMMANDED POSITION. 10.8 "LOW RETURN WATER TEMPERATURE ": GENERATE AN ALARM IF THE RETURN WATER TEMPERATURE TO THE BOILER FALLS BELOW 140°F. 11 TRENDS 11.1 CONTROL POINTS MONITORED BY THE BAS ARE CAPABLE OF BEING TRENDED. 11.2 THE BAS SYSTEM SHALL PRODUCE TRENDS FOR THE FOLLOWING CONTROL POINTS: 11.2.1 BOILER ENTERING AND LEAVING WATER TEMPERATURES . 11.2.2 BOILER FIRING RATE 11.2.3 OUTSIDE AIR TEMPERATURE 11.2.4 SUPPLY FAN MOTOR STATUS 11.2.5 SPACE TEMPERATURE 11.2.6 INDOOR AND OUTDOOR RELATIVE HUMIDITY 11.3 TREND DATA SHALL BE RECORDED OVER 15 MINUTE TIME INTERVALS AND SHALL BE COMPILED IN A SINGLE TREND STUDY. 11.4 THE MOST RECENT THREE MONTHS OF TRENDS SHALL BE REMOTELY ACCESSIBLE. OLDER DATA SHALL BE MADE AVAILABLE UPON REQUEST. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2012 City of Tukwila BUILDING DIVISION PG1), 12 SAFETY PROTOCOL 12,1 BOILER BURNER SAFETY OPERATIONS SHALL BE INTEGRAL TO THE OPERATION OF THE BOILER. THERE SHALL BE NO BAS SAFETY INTERACTION REQUIRED. l 9 9 RECEIVED CITY OF TUKWILA OCT 10 2012 PERMIT CENTER For Th instry le Of Your Buliding SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 - 331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: TRACK POOL ,, J REVISIONS: 8/7/12 50% DD 9/4/12 75% CD'S 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN- BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31/12 AS SHOWN HEATING WATER PIPING AND CONTROLS DIAGRAMS SHEET NUMBER: M6.0 FROM CITY WATER 314" WATER HEATER MEN'S LOCKER ROOM 314" TO POOL FILL 314" 112" SHOWER (ADA) 314" 314" 1 -112" WATER CLOSET WOMEN'S SINGLE USE I MEN'S STAFF 314" _� J F FIRST AID DRINKING FOUNTAIN 314 " — HOSE BIB DRINKING FOUNTAIN WOMEN'S STAFF ArnaribarimeaWral REVIEVVED FOR CODE COMPLIANCE APPROVED • NOV 0 8 2012 City of Tukwila BUILDING DIVISION PLUMBING ONE -LINE DIAGRAM DEMO KEY NOTES SCALE: NOT TO SCALE SCALE: NOT TO SCALE DEMOLISH FLUSHOMETERS. DEMOLISH FLUSHOMETERS. U2 ADD ALTERNATE: DEMOLISH ISOLATION VALVES. INCLUDE ISOLATION VALVES NOT IDENTIFIED ON MECHANICAL PLANS AND NOTE ON AS —BUILT DRAWINGS. SERVICE SINK JANITOR CLOSET WASHER %(;i..i e RECEIVED CITY OF TUKWILA OCT 1 0 2012 PERMIT CENTER instry fe Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1 -800 -669 -6223 PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 - 331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: POOL �. TRACK REVISIONS: 8/7/12 50% DD 9)4/12 75% CD'S 9/26/1,2 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31/12 AS SHOWN SHEET TITLE: PLUMBING ONE -LINE DIAGRAM -DEMO SHEET NUMBER: MD6.1 FROM CITY WATER SHEET NOTES 1. PIPE SIZES SHOWN ARE BASED ON INFORMATION FROM THE MECHANICAL DRAWINGS DATED 6 -29 -1990 AND ARE FOR REFERENCE ONLY. DOCUMENT DISCREPANCIES ON AS —BUILT DRAWINGS. M L -1 U-1 1-1 U ; MEN'S SINGLE USE • . ,0101 1 MEN'S LOCKER ROOM EXPANSION TANK WC-1 314 " --\ f r \40,441k- 1114" • WOMEN'S LOCKER ROOM . L___ —�_W ._.__.__. • SH-3 • • 314" HOSE BIB 314"— 1 -112" DRINKING FOUNTAIN " h 17 1 -112" L -1 SH -1 WOMEN'S STAFF WOMEN'S SINGLE USE PLUMBING ONE -LINE DIAGRAM .— SCALE: NOT TO SCALE _J DRINKING FOUNTAIN KEY NOTES SERVICE SINK LJANITOR CLOSET REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2012 City of Tukwila BUILDING DIVISION O PROVIDE FLUSHOMETERS. ® PROVIDE ISOLATION VALVES. INCLUDE ISOLATION VALVES NOT IDENTIFIED ON MECHANICAL DRAWINGS. ® PROVIDE FIXTURE. ® PROVIDE FIXTURE, SHOWER PAN AND SURROUND. ® PROVIDE SPOOL PIECE FOR HOT WATER LINE AND CAP. ® REPAIR LEAK IN SUPPLY PIPING, COORDINATE ISSUE WITH OWNER FOR DETAILS. 69 RECEIVED CITY OF TUKWILA OCT 10 2012 PERMIT CENTER For Th instry le Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800-669 -6223 PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 - 331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: TRACK POOL \. IMMOOMMOMMOMMENIMIMMONNIN REVISIONS: 8/7/12 50% DD 9/4/12 75% CD'S 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION MilliMOMMINMEMMONNIMEM McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31/12 AS SHOWN PLUMBING ONE -LINE DIAGRAM SHEET NUMBER: M6.1 FAN SCHEDULE DESCRIPTION UNIQUE TAG # SF -1 LOCATION OF FAN (ROOFTOP / ROOM NAME 1 PLAN GRID COORDINATES) FAN MECH ROOM BLADE TYPE (PROP / B1/ FC 1 PLUG / MIXED./ DIAMETER) MIXED DRIVE TYPE AND HOUSING (BELT / DIRECT ; CABINET / SWSI / INLINE ; CW / CCW ) BELT, INLINE CONTROL OF FAN (VARIABLE SPEED / CONSTANT / STAGED ARRAY) CONSTANT AREA OF BUILDING 1 SYSTEM SERVED NATATORIUM MANUFACTURER DATA MANUFACTURER GREENHECK MODEL NUMBER (INCL. CLASS, ARRANGEMENT, ROTATION WHERE APPLICABLE) QEI -33 -II -200 MATERIALS OF CONSTRUCTION (UL 762 GREASE / SPARK RESISTANT/ ENAMEL PAINT) HI -PRO POLLYESTER COAT MOTOR DESCRIPTION (ODP 1 TEFC / ECM) TEFC FAN MOTOR EFFICIENCY (BY NEMA STANDARD MG -1, %) 91 AGENCY LISTING (UL / ETL) UL PHYSICAL DIMENSIONS LENGTH x WIDTH x HEIGHT (IN.) 65x50x77 INLET / OUTLET DIMENSIONS (IN.) 46146 ACCESS & SERVICE CLEARANCE (FRONT / REAR 1 LEFT / RIGHT / TOP, IN) 42/6/0/0/6 OPERATING WEIGHT (LBS) 1644 PERFORMANCE , DESIGN AIRFLOW (CFM) 21,000 CFM DESIGN TOTAL STATIC PRESSURE ( "W.C.) 3.5 DESIGN FAN SPEED (RPM) 1177 DESIGN FAN BRAKE HORSEPOWER (BHP) 16.8 ELECTRICAL DATA VOLTAGE 1 PHASE (V /1e OR V /313) 208/3 POWER RATING OF MOTOR PROVIDED (MHP) 20 MOTOR EFFICIENCY 93% ALTERNATE POWER SOURCE REQUIRED N/A VARIABLE FREQUENCY DRIVE REQUIRED YES VARIABLE FREQUENCY DRIVE PROVIDED BY ELECT DISCONNECT PROVIDED BY ELECT CODE REQUIRED ELECTRICAL OUTLET PROVIDED BY ELECT ACOUSTICAL & SEISMIC FAN SPRING ISOLATION REQUIRED? YES SEISMIC ATTACHMENT METHOD (BOLT TO SLAB / WAFFLE PAD / SPRINGS & SNUBBERS) SPRINGS & SNUBBERS DUCT CONNECTION ISOLATION REQUIREMENTS FLEX DUCT MANUFACTURER'S CERTIFICATE OF SEISMIC COMPLIANCE INCLUDED PER IBC 1708.4 YES SOUND POWER AT DESIGN CONDITION (RE 10 -12W) PER ARI 370 -2001: N/A FOR 63 Hz BAND (INLET / DISCHARGE, dB): 79 /87 FOR 125 Hz BAND (INLET / DISCHARGE, dB): 88 /89 FOR 250 Hz BAND (INLET / DISCHARGE, dB): 93 /92 FOR 500 Hz BAND (INLET / DISCHARGE, dB): ; 90196 FOR 1000 Hz BAND (INLET / DISCHARGE, dB): 86 /90 FOR 2000 Hz BAND (INLET / DISCHARGE, dB): 82 /86 FOR 4000 Hz BAND (INLET / DISCHARGE, dB): 78/81 FOR 8000 Hz BAND (INLET / DISCHARGE, dB): 69 /72 NOTES 1. VFD REQUIRED PER WSEC, USE FOR SYSTEM BALANCING. 1. FURNISH WITH INERTIA BASE AND 1" SPRING ISOLATION. GAS BURNER DESCRIPTION UNIQUE TAG# B-1 LOCATION OF BURNER (FLOOR #, ROOM NAME) MECHANICAL ROOM QUANTITY 1 SYSTEM SERVED HEATING WATER FUEL (NATURAL GAS / DIGESTOR GAS/ PROPANE / OTHER) NATURAL GAS VENT METHOD (DIRECT / SIDEWALL / VERTICAL POSITIVE / VERTICAL NEGATIVE) DIRECT WILL COMBUSTION AIR BE DUCTED TO BURNER? (YES / NO) YES MANUFACTURER DATA , MANUFACTURER RIELLO MODEL NUMBER RS 100 /E COMBUSTION AIR APPROVED MATERIAL PVC BUILDING AUTOMATION SYSTEM INTERFACE PROVIDED? YES ARE ALARM CONTACTS PROVIDED FOR BULDING SYSTEM MONITORING? YES PHYSICAL DIMENSIONS OVERALL LENGTH x WIDTH x HEIGHT WITHOUT HOUSEKEEPING PAD (IN.) 33"x22"x22" OPERATING WEIGHT, INCLUDE FLUID (LBS.) 150 GAS CONN. SIZE, TYPE (IN.) 3" NPT PERFORMANCE NATURAL GAS MINIMUM INPUT PRESSURE (IN. W.G.) 8" NATURAL GAS MAXIMUM INPUT PRESSURE (IN. W.G.) 14" NATURAL GAS MAXIMUM INPUT FLOW (MBH) 4,405 ELECTRICAL QUANTITY OF ELECTRICAL CONNECTIONS (INCLUDING PUMP IF REQUIRED) 1 VOLTAGE /PHASE (FOR EACH CONNECTION) 208/3 STANDBY ELECTRICAL POWER REQUIRED (YES /NO) ? NO DISCONNECT PROVIDED BY: ELECTRICAL NOTES: 1. GAS REGULATOR TO BE FURNISHED BY MECHANICAL CONTRACTOR 2. PROVIDE BURNER WITH 1E2 MOTOR 3. DERATE BURNER FROM 4405 MBH TO 4200 MBH MAXIMUM INPUT FLOW MOTOR SCHEDULE TAG # M -1 M -2 MANUFACTURER LEESON LEESON - MODEL NUMBER C184T17WB8A C145T17WB22A QUANTITY 1 1 SERVICE. LOCKER ROOM SUPPLY FAN LOCKER ROOM ' EXHAUST FAN MOTOR HORSEPOWER 5 2 BRAKE HORSEPOWER 2.81' 1.25 RPM 1800 1800 VOLTAGE /PHASE 208V /3PH 208V /3PH FRAME 184T 145T QUANTITY OF ELECTRICAL CONNETIONS 1 1 WIDTH x DEPTH x HEIGHT 8.5 "x10 "x17" 7.4 "x14 "x7.3" WEIGHT 90 48 LB NOTES 1,3 2,3 NOTE: 1. PROVIDE MOTOR AND FAN SHEAVE TO BALANCE SUPPLY FAN TO 3180 CFM 2. PROVIDE MOTOR AND FAN SHEAVE TO BALANCE EXHAUST FAN TO 3980 CFM 3. MOTORS TO BE SUITABLE FOR USE IN A HUMID CHLORINATED ENVIRONMENT. PLUMBING FIXTURE SCHEDULE TAG WC -1 WC -2 L -1 L-2 L -3 L-4 SH -1 SH -2 SH -3 U -1 DESCRIPTION WATER CLOSET ADA WATER CLOSET LAVATORY ADA LAVATORY LAVATORY FAUCET LAVATORY FAUCET SHOWER ADA SHOWER SHOWER N/A LOCATION LOCKERS /BATHROOMS LOCKER ROOMS LOCKERS /BATHROOMS/ STAFF LOCKER ROOMS FIRST AID JANITOR ROOM MEN'S STAFF LOCKER ROOMS - LOCKER ROOMS MEN'S LOCKERS /BATHROOM MANUFACTURER ZURN ZURN ZURN ZURN N/A N/A ZURN ACCESS ACORN N/A MODEL Z5615 Z5615 Z5314 Z5314 N/A N/A Z 7101 -LHSS • . Z7000 -HW13 -1.75 SHOWER -WARE 700 SERIES N/A TYPE WALL HUNG WALL HUNG WALL HUNG WALL HUNG N/A N/A PRESSURE BALANCE CARTRIDGE, BLADE HANDLE, INTEGRAL STOPS • HAND HELD WITH METAL HOSE AND MOUNTING BAR CAPITAL COLUMN N/A DIMENSIONS N/A N/A 20 "x18" 20 "x18" N/A N/A N/A N/A N/A N/A SEAT OLSONITE IOCC OR ZURN 5955SS -EL, ELONGATED, OPEN FRONT, SOLID PLASTIC SEAT OLSONITE 10CC OR ZURN 5955SS -EL, ELONGATED, OPEN FRONT, SOLID PLASTIC SEAT N/A WA N/A . N/A N/A N/A N/A N/A FLUSH VALVE ZURN Z6000- AV -WS1, BRASS WITH CHROME FINISH, MANUAL FLUSH ZURN Z6000- AV -WS1, BRASS WITH CHROME FINISH, MANUAL FLUSH N/A WA N/A N/A N/A NIA N/A ZURN Z6003- AV -WS1, BRASS WITH CHROME FINISH, MANUAL FLUSH FLOW RATE 1.6 GALLONS PER FLUSH 1.6 GALLONS PER FLUSH 0.5 GPM 0.5 GPM 0.5 GPM N/A 1.75 GPM 1.75 GPM 1.6 GPM 1 GALLON PER FLUSH CARRIER ZURN 1200 SERIES ZURN 1200 SERIES ZURN 1200 SERIES ZURN 1200 SERIES N/A N/A N/A N/A N/A N/A FAUCET MANUFACTURER N/A N/A ZURN ZURN ZURN ZURN • N/A ZURN N/A NIA FAUCET MODEL N/A NIA Z86500 -3M Z86500 -3M Z871C4 Z841N1 N/A N/A N/A N/A FAUCET DESCRIPTION N/A N/A SELF CLOSING METERING FAUCETS, 4" SPOUT SELF CLOSING METERING FAUCETS, 4" SPOUT POLISHED CHROME PLATED 8" BRASS DECK FAUCET POLISHED CHROME- PLATED CAST BRASS SERVICE SINK FAUCET N/A PRESSURE BALANCE CARTRIDGE, BLADE HANDLE, INTEGRAL STOPS , N/A N/A SHOWER HEAD MANUFACTURER N/A N/A N/A N/A N/A N/A ZURN ZURN ACORN SHOWER HEAD MODEL N/A N/A N/A N/A N/A N/A Z-7006-88 N/A N/A SHOWER HEAD DESCRIPTION N/A • N/A N/A N/A N/A N/A CHROME PLATED SHOWER HEAD NON-ADJUSTABLE SPRAY PATTERN SOLID BRASS, TRIPLE CHROME PLATED ' DRAIN N/A NIA ZURN Z8743 GRID STRAINER OR APPROVED ZURN Z8743 GRID STRAINER OR APPROVED N/A WA N/A N/A N/A N/A TRAP N/A N/A 1 -1/2" 17 GAUGE, CHROME PLATED 1 -1/2" 17 GAUGE, CHROME PLATED 1 -1/2" 17 GAUGE, CHROME PLATED N/A N/A N/A N/A N/A TRAP PRIMER N/A N/A N/A N/A N/A N/A N/A • N/A N/A N/A SUPPLIES N/A N/A 20" CHROME SUPPLIES W/ 3/8" COMP. FITTINGS, ANGLE STOPS AND ESCUTCHEON PLT, KEYLESS (COMMERCIAL) 20" CHROME SUPPLIES W/ 3/8" COMP. FITTINGS, ANGLE STOPS AND ESCUTCHEON PLT, KEYLESS (COMMERCIAL) W/ 3/8" COMP. FITTINGS, ANGLE STOPS AND ESCUTCHEON PLT, KEYLESS (COMMERCIAL) N/A N/A N/A N/A N/A NOTES 1 1 1,5 1,5 2,3,4,6 1 NOTES 1. TOILETS AND WATER CLOSETS ARE TO BE MANUAL FLUSH 2. DISCHARGE HEIGHT OF ACORN SHOWERS TO BE 6' -0" 3. PROVIDE FOUR - SHOWER STATIONS. 4. PROVIDE COLUMN EXTENSION FOR WATER CONNECTIONS FROM ABOVE. 5. 4" ON CENTER FAUCET AND HOLES 6. PROVIDE DRAIN BASE WITH DOME GRATE PUMP SCHEDULE TAG # P -1 P -3 P-4 AREA MECHANICAL ROOM MECHANICAL ROOM MECHANICAL ROOM BASIS OF DESIGN B &G B &G B &G MODEL NUMBER 1510 SERIES 2BC e3- 6 /BUXRC e5-6 /BUXRC SERVICE BUILDING HEATING WATER LOOP DHW CIRCULATION DHW CIRCULATION LOCATION MECHANICAL ROOM BOILER ROOM BOILER ROOM GPM 130 3 3 FT. TOTAL HEAD 62 5 5 FT. NPSH 6 - -- MAX FLUID PRESSURE PSIG 175 150 150 MOTOR HP 5 28W 28W BRAKE HP 4.25 N/A N/A VOLTAGE /PHASE 208V /3PH 115 / 1 115 / 1 MOTOR EFFICIENCY ' PER WSEC PER WSEC PER WSEC RPM 1,750 - - VFD NO NO. NO VFD BYPASS NO NO NO EMERGENCY POWER NO NO NO ELECTRICAL CONNECTION BY ELECT BY ELECT BY ELECT WEIGHT (LBS.) 250 LBS <10LBS <10LBS REMARKS 3.5 1,2,4,5 1,2,4,5 NOTES: 1. FURNISH WITH TIMER 2. FURNISH'WITI-I INTERNAL ADJUSTABLE TEMPERATURE SENSOR 3. FURNISH SUCTION DIFFUSER 4. FURNISH WITH ISOLATION VALVES FOR SERVICE 5. REFERENCE POOL CONSULTANT DRAWINGS FOR ADDITIONAL PUMPS BEING INSTALLED. GAS WATER HEATER SCHEDULE TAG # DWH -1 ST-1 MANUFACTURER A.O.SMITH A.O.SMITH MODEL NUMBER CYCLONE XI BTH 500 TJV 200 -M QUANTITY 1 1 SERVICE DOMESTIC HOT WATER DOMESTIC HOT WATER CAPACITY (GALLONS) 130 200 ENTERING WATER TEMPERATURE 40 °F N/A LEAVING WATER TEMPERATURE 130 °F N/A WATER CONNECTION SIZE (NPT) . • 1 1/2" 2" GALLONS PER HOUR RECOVERY @ 100 DEGREE TEMPERATURE RISE 640 WA GAS INPUT CAPACITY 499,900 BTUH N/A MINIMUM GAS PRESSURE 5" W.G. NIA MAXIMUM GAS PRESSURE 10" W.G. N/A GAS CONNECTION SIZE (NPT) 1 -1/2" N/A CONCENTRIC VENT NO N/A FLUE PIPE MATERIAL • PVC N/A FLUE PIPE DIAMETER 6" . N/A PRESSURE RELIEF VALVE SETTING (PSI) 150 - 150 ELECTRIC REQUIREMENTS 120/1/60 N/A QUANTITY OF ELECTRICAL CONNETIONS 1 N/A BLOWER ELECTRIC REQUIREMENTS 2.2 AMPS N/A IGNITER ELECTRIC REQUIREMENTS 4.0 AMPS N/A WIDTH x DEPTH x HEIGHT 33x76 32x77 WEIGHT WITH WATER 1934 LBS 2220 LBS ASME TANK YES YES NOTES 1 N/A NOTE: 1. PROVIDE CONDENSATE NEUTRALIZATION KIT For Th instry ife Of Your Building REVIEWED FOR CODE COMPLIANCE APPROVED NOV 082012 City of Tukwila BUILDING DIVISION METER SCHEDULE TAG # WM -1 WM -2 AREA MECHANICAL ROOM MECHANICAL ROOM BASIS OF DESIGN BADGER ONICON MODEL NUMBER TSM 450 F3200 METER TYPE RECORDALL TURBO SERIES FLOW METER j IN -LINE WAFER STYLE ELECTROMAGNETIC FLOW METER SERVICE POOL FILL METER POOL DRAIN METER LOCATION POOL FILTER ROOM BOILER MECHANICAL ROOM CONNECTION SIZE • 3" 4" DIMENSIONS (LxWxH) 12 "x7.5 "x9" 6 "Lx6 "W OPERATIONAL RANGE 5 -550 GPM 4 -812 GPM REMARKS s 1,2,3 3,4 NOTES: 1. FURNISH WITH RECORDALL TRANSMITTER REGISTER 2. FURNISH WITH INTEGRAL STRAINER 3. CONNECT TO BAS 4. FURNISH WITH 316SS GROUNDING RINGS AND INTERNAL TEFLON COATING °Kg RECEIVED CITY OF TUKWILA OCT 1 0 2012 PERMIT CENTER SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1.800 -- 669 --6223 MENNIMMININNEMIN PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503 -331 --0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: POOL TRACK REVISIONS: . 8/7/12 50% DD 9/4/12 75% CD'S 9/26/12 90% CD'S . 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED 8Y: DRAWN 8Y: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31/12 AS SHOWN SHEET TITLE: EQUIPMENT SCHEDULES SHEET NUMBER: M7.0 HVAC PIPING SPECIFICATION (WSEC); LATEST REVISION: 9- 29 -2011 ID CATEGORY SERVICE DESCRIPTION MANUFACTURER, PRODUCT OR EQUAL PRESSURE TEST PROCEDURE SEISMIC INSULATION MEDIA TEST PRESSURE DURATION CODE IMPORTANCE IP 8" or Larger HANGERS DOMESTIC COLD WATER ALL 0.23 -0.27 75 FIBERGLASS 0.50 in 0.50 in 0.50 in HS&R HEATING HOT WATER HVAC HEATING NOTES 1, 2, & 4 WATER 1.5 TIMES MAX OPERATING • PRESSURE, BUT NOT LESS THAN 100 PSI 15 MINUTES 2p091MC SECTION 1208 1.0 PER W.S.E.0 SEE INSULATION SCHEDULE INSERTS AT HANGERS INSERTS AS NORMAL OPERATING PRESS & TEMP: UP TO 100 PSI; 140 F TO 200 F; RELIEF TO REMAIN AS EXISTING 1.50 in 1.50 in 1.50 in NOTES 1, 2, & 4 PIPE MATERIAL SIZES THRU 2" COPPER TUBE TYPE L ASTM B88 r PER SUBMITTAL JOINTS SWT; THREADED AT SPECIALTIES AS APPLICABLE PER SUBMITTAL FITTINGS WROT COPPER/BRONZE SWT JOINT PER SUBMITTAL FLANGES, UNIONS, & COUPLINGS CAST BRASS / WROT COPPER; CLASS 150 PER SUBMITTAL WYE STRAINERS BRONZE BODY KECKLEY E150 pm)/ F150 (FPT) EXPANSION JOINTS COMPENSATION FITTING AND /OR PIPING LOOP METRALOOP; DME; GLOBAL CM / CMS VALVES - ISOLATION 2 -PC BALL - FPT MILWAUKEE BA -400, NIBCO T-585-70 VALVES - ISOLATION 2 -PC BALL - SWT MILWAUKEE BA -450, NIBCO S-585-70 VALVES - CHECK HORIZONTAL SWING, BRONZE BODY - THREADED MILWAUKEE -510 / - 1510 -T, NIBCO - 433 -Y VALVES - BALANCE CIRCUIT SETTER WITH TEST PORTS ARMSTRONG CBV; B &G CB VALVES - AUTO-BALANCE AUTO -FLOW CONTROL GRISWOLD / BELL & GOSSETT VALVES - DRAINING 2 -PC BALL - HOSE END WITH CAP & CHAIN . MILWAUKEE BA- 100HTA / BA- 150HTH FLEX CONNECTIONS - PUMPS 1 AHUs BRAIDED FLEX . PER SUBMITTAL FLEX CONNECTIONS - TERMINAL UNITS HOSE KIT- BRAIDED FLEX, STRAINER, VALVES, PT PLUGS PER SUBMITTAL . PRESSURE GAUGES SYSTEM PRESSURES STD 0 -150 PSI (OIL-FILLED AT ROTATING EQUIP) TRERICE 600 CB, 4.5" THERMOMETERS SYSTEM TEMPERATURE STD 0 -100 F TRERtCE BX 1 WITH THERMO WELL PIPE MATERIAL 2 -1/2" AND UP CARBON STEEL PIPE ASTM A53B ERW SCH STD ASME 16.5 PER SUBMITTAL JOINTS GROOVED PER SUBMITTAL JOINTS BUTT WELD ASME B16.3 - STATE ON PLANS TO WELD INSIDE CONCEALED SHAFTS AND ABOVE NON ACCESSIBLE CEILINGS? PER SUBMITTAL FITTINGS CARBON STEEL STD WT BUTT WELD / GROOVED PER SUBMITTAL FLANGES CARBON STEEL; CLASS 150 PER SUBMITTAL COUPLINGS ZERO -FLEX GROOVED PER SUBMITTAL WYE STRAINER CAST IRON; CLASS 125 KECKLEY STYLE A EXPANSION JOINTS COMPENSATION FITTING AND /OR PIPING LOOP METRALOOP; DME; GLOBAL CM / CMS VALVES - ISOLATION BUTTERFLY CLASS 150 LUG BODY MILWAUKEE CL 223E / CL -323E VALVES - ISOLATION BUTTERFLY - GROOVED ANVIL AN-7721 /,AN -7722 VALVES - CHECK SWING / SPRING MILWAUKEE F 2974(M), SILENT CHECK 1800 VALVES - PLUG CAST IRON; CLASS 125 (AT PUMP DISCHARGE WHEN NO VFD) RESUN 1431 VALVES - BALANCE CIRCUIT SETTER WITH TEST PORTS ARMSTRONG CBV; B&G CB VALVES - AUTO - BALANCE AUTO -FLOW CONTROL GRISWOLD / BELL & GOSSETT COND CONDENSATE PIPING TO DRAIN HVAC CONDENSATE DRAIN SLOPE TO INDIRECT WASTE N/A WATER PLUGS & FILL . MIN15 MINUTES; VISUAL CHECKS FOR LEAKS 2009 UPC, SECTION 723.0 1.O VARIES NORMAL OPERATING PRESSURE ATMOSPHERIC MATERIAL SIZES THRU 3" COPPER TUBE TYPE L ASTM B88 PER SUBMITTAL JOINTS ST; THREADED AT SPECIALTIES AS. APPLICABLE W PER SUBMITTAL FITTINGS WROT COPPER/BRONZE SWT JOINT PER SUBMITTAL FLANGES, UNIONS, & COUPLINGS CLASS 150 CAST BRASS/ WROT COPPER PER SUBMITTAL LPG, MPG LOW PRESSURE NATURAL GAS MEDIUM PRESSURE NATURAL GAS FUEL. GAS DISTRIBUTION NA AIR 150% OF WORKING PRESSURE BUT NOT LESS THAN 3 PSIG 1/2 HOUR PER 500 CUBIC FEET OF PIPE VOLUME, NOT MORE THAN 24 HOURS 2009 IFGC, SECTION 406 1.5 NA NORMAL OPERATING PRESSURE: 0 TO 5 PSI PIPE MATERIAL SIZES THRU 2" CARBON STEEL PIPE A538 ERW SCH STD ASME 16.5 PER ,SUBMITTAL JOINTS, THREADED AND COUPLED, PIPE SEALANT PER SUBMITTAL FITTINGS, UNIONS, & COUPLINGS MALLEABLE IRON, UNION CLASS 150 ASME B16.3 PER SUBMITTAL FLEX CONNECTIONS AGA APPROVED GLOBAL FLEX UN SERIES VALVES - ISOLATION BALL MILWAUKEE BB2 -100 OR NIBCO T-585-70-UL VALVES - ISOLATION PLUG RESUN R- 1430; NORDSTROM EQUAL ALTERNATE SIZES THRU 2" PIPE MATERIAL ASTM A240 TYPE 300 CORRUGATED SS TUBING GASTITE JOINTS ALTERNATE PROPRIETARY FLARED FITTINGS GASTITE FITTINGS ALTERNATE PROPRIETARY FLARED FITTINGS GASTITE ALTERNATE SIZES 2 -112" AND UP PIPE MATERIAL CARBON STEEL PIPE A53B ERW SCH STD ASME 16.5 PER SUBMITTAL JOINTS BUTT WELD PER SUBMITTAL FITTINGS BUTT WELD ASME B16.9 PER SUBMITTAL FLANGES, UNIONS, & COUPLINGS CLASS 150; FORGED STEEL . PER SUBMITTAL FLEX CONNECTIONS AGA APPROVED GLOBAL FLEX UN SERIES VALVES - ISOLATION PLUG RESUN R -1431; NORDSTROM EQUAL PIPE & EQUIPMENT INSULATION SCHEDULE PIPING SYSTEM TEMP RANGE THERMAL CONDUCTANCE MEAN RATING TEMPERATURE INSULATION MATERIAL INSULATION THICKNESS BY PIPE SIZE INSUL. Runoul's to 2" 3/4" or Less 1" to <1 -112" 1- 112" to <4" 4" to <8" 8" or Larger HANGERS DOMESTIC COLD WATER ALL 0.23 -0.27 75 FIBERGLASS 0.50 in 0.50 in 0.50 in 1.00 in 1.00 in 1.00 in NOTES 1, 2, & 4 DOMESTIC HOT WATER > 105 0.24 -0.28 100 FIBERGLASS 1.00 in 1.00 in 1.00 in 1.50 in 1.50 in 1.50 in NOTES 1, 2, & 4 HEATING WATER 141 -200 0.25 -0.29 125 FIBERGLASS 1.50 in 1.50 in 1.50 in 1.50 in 2.00 in 2.00 in NOTES 3 & 4 CONDENSATE DRAINS ALL 0.23 -0.27 75 FIBERGLASS 0.50 in 0.50 in 0.50 in 0.50 in 1.00 in 1.00 in NOTES 1, 2, & 4 NOTES 1 FOR PIPING CLAMPED TO UNISTRJJT SUPPORTS, UTILIZE RIGID INSERTS WITH SHEETMETAL SHIELDS CONTINUOUS THROUGH THE HANGER; UTILIZE CALCIUM SILICATE INSERTS OE STYRENE INSERTS 2 FOR PIPING SUPPORTED FROM CLEVIS HANGERS, IF RIGID INSERTS ARE NOT UTILIZED THE INSULATION SHALL FULLY ENCLOSE THE HANGER AND BE SEALED AT THE TOP AROUND THE SUPPORT ROD; IF RIGID INSERTS ARE UTILIZED THE INSULATION SHALL BE CONINUOUS THROUGH THE HANGER; INSERT MATERIAL TO BE CALCIUM SILICATE INSERTS OR STYRENE INSERTS 3 UTILIZE RIGID INSERTS AND SHEETMETAL SHIELDS; INSULATION TO BE CONTINUOUS THROUGH THE HANGER; UTILIZE CALCIUM SILICATE INSERTS OR STYRENE INSERTS 4 JACKETING: METAL JACKETING (SEALED WEATHER TIGHT) WILL BE APPLIED ON ALL EXTERIOR INSULATION EXPOSED TO WEATHER (LE. ROOFTOP PIPING). PVC JACKET WITH RIGID INSULATION WILL BE USED INDOORS ON HORIZONTAL PIPING AT OR NEAR THE FLOOR WHEN SUBJECT TO POTENTIAL FOOT TRAFFIC. PVC JACKETING WILL BE UTILIZED ON ALL EXPOSED INSULATION WITHIN 6 FEET OF THE FLOOR ELEVATION (LE. MECHANICAL ROOMS AND GARAGE HOSE BIBBS); PVC IS RECOMMENDED INSTEAD OF METAL IN EXPOSED AREAS DO TO ITS RESILIENCY - METAL JACKETING WILL DENT AND REMAIN DEFORMED WHEREAS PVC WILL POP BACK TO ORIGINAL CONDITION EXPANSION TANK SCHEDULE DESCRIPTION TAG - ET-2 LOCATION MECHANICAL ROOM QUANTITY 1 TYPE AND ARRANGEMENT (CLOSED / BLADDER / DIAPHRAGM) BLADDER SYSTEM SERVED - HEATING WATER BASIS OF DESIGN AS APPROVED FOR CONSTRUCTION OR AS PROPOSED? PROPOSED MANUFACTURER ITT MODEL NUMBER D -100V MATERIALS OF CONSTRUCTION STEEL ASME RATING . YES PHYSICAL DIMENSIONS DIAMETER x HEIGHT (IN) 16x69 SERVICE CLEARANCE (FRONT/ REAR/ LEFT/ RIGHT / TOP) (IN) 18 OPERATING WEIGHT, TANK AND WATER (LBS) 632 CONNECTION SIZE . 1/2" PERFORMANCE SYSTEM VOLUME (GAL) 500 SYSTEM LOWER TEMPERATURE ( °F) 50 SYSTEM HIGHER TEMPERATURE ( °F) 200 SYSTEM PRESSURE AT LOWER TEMPERATURE (PSIG) 25 SYSTEM PRESSURE AT HIGHER TEMPERATURE (PSIG) 45 EXPANSION TANK VOLUME REQUIRED (GAL) 52 EXPANSION TANK VOLUME SELECTED (GAL) 55 TANK ACCEPTANCE VOLUME REQUIRED / MAXIMUM (GAL) 19/22.6 RELIEF VALVE SETTING (PSIG) 50 ' SEISMIC SEISMIC ATTACHMENTS: YES QUANTITY OF MOUNTING POINTS PER MFG FACTORY CERTIFIED STAMPED CALCULATIONS INCLUDED PER IBC -1621 PER STRUCTURAL AIR! DIRT SEPARATOR SCHEDULE TAG # AS -1 LOCATION BOILER ROOM SERVES HEATING WATER SYSTEM BASIS OF DESIGN MANUFACTURER SPIROTHERM MODEL NUMBER 'PHYSCIAL VDN 500 DIMENSIONS AND WEIGHT DIAMETER/HIGHT 12.8" / 41.7" INLET SIZE - INCHES 5 OUTLET SIZE - INCHES 5 TYPE OF INLET CONNECTION FLANGED TYPE OF OUTLET CONNECTION FLANGED SLOWDOWN DRAIN CONNECTION - INCHES 1 OPERATING WEIGHT - POUNDS 325 PERFORMANCE FLUID TYPE WATER CAPACITY - GALLONS PER MINUTE 263 ACTUAL PRESSURE DROP - FEET OF HEAD 0.8 VERTICAL STRAINER YES BRACKETS FOR SEISMIC BRACING YES CONSTRUCTION MATERIALS SHELL CARBON STEEL ASME SECTION VIII, DIVISON 1 YES MAXIMUM WORKING PRESSURE - PSIG 150 MAXIMUM OPERATING TEMPERATURE - F 270 NVItS 1. PROVIDE MBV -1 MANUAL BLOW DOWN VALVE • 2. PROVIDE PIPE TRANSITIONS AT FLANGED CONNECTIONS moo,•,- P..___ REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 21312 City of Tukwila BUILDING DIVISION GAS PRESSURE REDUCING VALVE BASIS OF DESIGN MAX INDIVIDUAL LOAD (BTU /HR) OPERATING TEMP RANGE ( °F) PIPE SIZE (NPT) VENT CONNECTION SIZE (NPT) INLET GAS PRESSURE STANDARD SPRING ORIFICE SIZE NOTES TAG # MAKE MODEL QTY PRV -1 ITRON B31R • 1 500,000 LO -20 HIGH 150 1 -1/2" 1" 2 PSI • 5.5 - 8 IN. WC 5/16" 1 PRV -2 ITRON B34R 1 4,200,000 LO -20 HIGH 150 2" 1" 2 PSI 8 -14 IN. WC 7/8" 1 1. VALVE PROVIDED BY MECHANICAL CONTRACTOR PGiai tcy RECEIVED CITY OF TUKWILA OCT 1 0 2012 PERMIT CENTER instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1--800 -669 -6223 PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503- 331 -0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 miummatirrimmimum TENNIS COURT PARKING REGISTRATION: POOL TRACK REVISIONS: 8/7/12 50% DD 9/4/12 75% CD'S 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS N0. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31/12 AS SHOWN SHEET TITLE: EQUIPMENT SCHEDULES SHEET NUMBER: M7.1 PLUMBING SPECIFICATION (WSEC); LATEST REVISION: 8 -31 -11 ID CATEGORY SERVICE DESCRIPTION MANUFACTURER, PRODUCT OR EQUAL PRESSURE TEST PROCEDURE SEISMIC INSULATION MEDIA TEST PRESSURE DURATION CODE IMPORTANCE 1p FLOW CV VALVE MODULATING / POSITION TAG SERVED SIZE SIZE CW 8z HW HWC (POTABLE) COLD WATER (DOMESTIC) HOT WATER (DOMESTIC) HOT WATER CIRCULATION DOMESTIC HOT AND COLD WATER SERVICE MODEL AIR OR WATER 100% OF OPERATING. PRESSURE 15 MINUTES OR MFG SPEC UPC CHAPTER 6 NSF 61 UPC APPENDIXA IAPMO INSTALLATION STANDARDS 1.0 PER W.S.E.0 SEE INSULATION SCHEDULE NO INSERTS AT HANGERS USE INSERTS AT CLAMPS INSERTS TO BE STYRENE OPERATING PRESSURE UP TO 100 PSI; SET RELIEF TO 100 PSI NOTES CV-1 HC-1 1 PIPE MATERIAL SIZES THRU 2" COPPER TUBE TYPE L ASTM B88 PER SUBMITTAL JOINTS SWT; THREADED AT SPECIALTIES WHERE APPLICABLE PER SUBMITTAL FITTINGS • WROT COPPER / CAST BRONZE SWT JOINT PER SUBMITTAL VALVES - ISOLATION BALL TYPE - SWT MILWAUKEE BA-485B; NIBCO S- 585 -70 SPECIALTIES MISC. PROJECT SPECIFIC REQUIREMENTS CV-2 HC-2 1 PIPE MATERIAL SIZES 2 -1/2" THRU 4" COPPER TUBE TYPE L ASTM B88 PER SUBMITTAL JOINTS GROOVED PER SUBMITTAL. FITTINGS WROT COPPER / CAST BRONZE SWT JOINT PER SUBMITTAL VALVES - ISOLATION BUTTERFLY VICTAULIC SERIES 608 SPECIALTIES . MISC. ' PROJECT SPECIFIC REQUIREMENTS CV-3 HC-3 1 1 -1/2" 1" CCV ALTERNATE SIZES THRU 2" BELIMO B223 PIPE MATERIAL . COPPER TUBE TYPE L ASTM B88 PER SUBMITTAL 10.0 10 1.05 ALTERNATE SIZES 2 -1/2" THRU 4" YES 1,2,3,4 PIPE MATERIAL COPPER TUBE TYPE L ASTM B88 PER SUBMITTAL 1" 1/2" CCV ALTERNATE (DCW ONLY TO COMPLY WITH NSF 61) - SIZES 2 -1/2" AND UP BELIMO B214 PIPE MATERIAL STAINLESS STEEL PIPE TYPE 304L SCH 105 A312 SEAMLESS PER SUBMITTAL JOINTS ALTERNATE GROOVED PER SUBMITTAL FITTINGS ALTERNATE GROOVED TYPE 304 STAINLESS STEEL PER SUBMITTAL VALVES - ISOLATION GROOVED -END; BUTTERFLY; UPC - APPROVED ANVIL AN- 7721 -3; VICTAULIC SERIES 300 1 -1/4" 3/4" CCV ALTERNATE (PLASTIC) SIZES THRU 2" BELIMO B218 PIPE MATERIAL PEXASTM F876 /ASTM F877 PER SUBMIT'T'AL JOINTS INSERT TYPE (BRASS) W/ EXPANSION COLLAR PER SUBMITTAL FITTINGS PIPE INSERT + EXPANSION COLLAR ASTM F1807/ASTM F1960 PER SUBMITTAL VALVES - ISOLATION BALL MILWAUKEE BA -4845; NIBCO 5- 585 -70 SPECIALTIES MISC. PROJECT SPECIFIC REQUIREMENTS HEATING COIL BELIMO B261 W SANITARY WASTE - ABOVE GROUND CAST IRON SANITARY WASTE 70.0 WATER OR AIR WATER 10 FT HEAD FILL SYSTEM FROM LOWEST TO HIGHEST POINT OF TEST SECTION DO NOT USE AIR FOR PLASTIC PIPE TESTING VISUAL INSPECTION WITH NO LEAKS UPC CHAPTER 7 1.0 NIA OPERATING PRESSURE UP TO 5 PSI 4" 4" GLOBE MIXING PIPE MATERIAL ALL SIZES CAST IRON NO -HUB ASTM 'D2665 PER SUBMITTAL JOINTS NHCI COUPLINGS - STANDARD PER SUBMITTAL FITTINGS CAST IRON DRAIN PATTERNS PER SUBMITTAL SPECIALTIES CLEAN -OUT FITTINGS PER PLUMBING SCHEDULE ALTERNATE ALL SIZES PIPE MATERIAL PVC SCH DWV OR ABS SCH DWV PER SUBMITTAL JOINTS SOLVENT WELD PER SUBMITTAL FITTINGS SOLVENT WELD DWV FITTINGS PER SUBMITTAL SPECIALTIES MISC. PER PLUMBING SCHEDULE CONTROL VALVE SCHEDULE VALVE UNIT Q..Y PIPE VALVE VALVE VALVE VALVE VALVE CLOSE -OFF MIN. BODY SPRING RETURN FLOW CV VALVE MODULATING / POSITION TAG SERVED SIZE SIZE TYPE FUNCTION DESIGN MODEL RATING (PSI) RATING (PSI) TYPE GPM ACTUAL DP(PSI) OPEN -CLOSE FEEDBACK NOTES CV-1 HC-1 1 1 -1/2" 1 -1/2" CCV HEATING COIL BELIMO B338 200 400 • SPRING RETURN 21.7 19 1.30 MODULATING YES 1,2,3,4 CV-2 HC-2 1 1" 1/2" CCV HEATING COIL BELIMO B214 200 600 SPRING RETURN 5.6 5 1.05 MODULATING YES 1,2,3,4 CV-3 HC-3 1 1 -1/2" 1" CCV HEATING COIL BELIMO B223 200 600 SPRING RETURN 10.0 10 1.05 MODULATING YES 1,2,3,4 CV-4 HC-4 1 1" 1/2" CCV HEATING COIL BELIMO B214 200 600 SPRING RETURN 5.6 5 1.05 MODULATING YES 1,2,3,4 CV-5 HC -5 1 1 -1/4" 3/4" CCV HEATING COIL . BELIMO B218 200 600 SPRING RETURN 7,4 7 1.12 MODULATING YES 1,2,3,4 CV-6 HC-6 1 3" 2 -1/2" CCV HEATING COIL BELIMO B261 100 400 SPRING RETURN 70.0 60 1.38 MODULATING YES 1,2,3,4 CV-7 SPACE HEATING LOOP 1 4" 4" GLOBE MIXING BELIMO G7100 150 250 SPRING RETURN 130.0 190 0.47 MODULATING YES 1,2,3 NOTES: 1. VALVE FURNISHED BY CONTROL CONTRACTOR. 2. VALVE INSTALLED BY MECHANICAL CONTRACTOR. 3. VALVE WIRED BY CONTROLS CONTRACTOR. 4. PIPE SIZES ARE ESTIMATED BASED ON FLOW, MECHANICAL AS -BUILT DRAWINGS NOT AVAILABLE. PROVIDE ACTUAL PIPE SIZES DURING CONSTRUCTION FOR AS -BUILT DRAWINGS. HVAC DUCT SPECIFICATION (WSEC)" LATEST REVISION: 8-31 -11 PRESSURE CLASS DUCT MATERIALS FITTINGS FLEX CONNECTION! FLEX DUCT V SEAL CLASS CLEANLINESS DURING CONSTRUCTION INSULATION (INDOOR, OUTDOOR) LINING MATERIALS SEISMIC CRITERIA SEISMIC IMPORTANCE FACTOR IP NOTES DUCT SYSTEM SMACNA +1/2" OR +1" PRESSURE NOTE: MCKINSTRY BUILDS ALL LOW PRESSURE DUCTWORK IN ACCORDANCE WITH +1" SMACNA GUIDELINES TO MAXIMIZE PRODUCTION EFFICIENCY GALVANIZED DUCT; GAUGE AND REINFORCEMENT SHALL BE SMACNA OR BETTER RECTANGULAR MAY BE S +DRIVE ROUND MAY BE SNAPLOCK. ELBOWS: PURI4ASED ADJUSTABLE ELBOWS IN ACCORDANCE WITH SMACNA +1" STANDARDS CL RADIUS OF 1.0 DIA ON DUCTS LARGER THAN 24" SPIN -IN / ATTO BRANCHES OK 12 -FOOT MAX LENGTH WITH NO OFFSETS; USE THERMAFLEX; GKM, OR EQUAL +1" SMACNA SEAL CLASS LEVEL C +1/2" NO SEAL FOLLOW BASIC "LEVEL A" SMACNA FOLLOW BASIC "LEVEL B" SMACNA FOLLOW BASIC "LEVEL C" SMACNA ENGINEER TO SPECIFY WITHIN CONDITIONED SPACE: R- 3.3 WHEN NOT IN A CONDITIONED SPACE, USE R -7 WITH APPROVED VAPOR/WEATHER BARRIER IN CONCRETE OR GROUND: R- 5.3 LINING WHERE INDICATED ON THE PLANS ENGINEER TO CONSIDER LINING WHEN VELOCITY IS 1,400 FPM OR GREATER SEISMIC SUPPORT PER APPLICABLE CODE / LOCAL JURISDICTION. SEE MECHANICAL SEISMIC SHEET WHEN APPLICABLE. IP = 1.0 . IP = 1.5 (LAB PRESSURIZATION) . NOTES 1, 2, 3, 4, 5 'HVAC SUPPLY LOW PRESSURE TERMINALS TO DIFFUSERS FAN COL UNITS TO DIFFUSERS HEAT PUMPS TO DIFFUSERS GALVANIZED DUCT; GAUGE AND REINFORCEMENT SHALL BE SMACNA OR BETTER RECTANGULAR TO HAVE TDF CONNECTIONS ROUND MAY BE SNAPLOCK ELBOWS: CENTERLINE RADIUS OF 1.5 DIA OR MITERED 90S WITH VANES OR PURCHASED ADJUSTABLE ELBOWS IN ACCORDANCE WITH SMACNA +1" CL RADIUS OF 1.0 DIA ON DUCTS LARGER THAN 24" DIA TAPS: CONICAL OR BOOT -STYLE FLEXAT EQUIP CONNECTIONS -SMACNA TO COMPLY WTTti SMACNA APPLICABLE PRESSURE CLASS SEAL CLASS LEVEL C FOLLOW BASIC "LEVEL A" SMACNA FOLLOW BASIC "LEVEL B" SMACNA FOLLOW BASIC "LEVEL C" SMACNA ENGINEER 10 SPECIFY WITHIN CONDITIONED SPACE: R- 7 NOT WITHIN CONDITIONED SPACE: R-5.3 OSA DUCT W/ GREATER THAN 2800 CFM UPSTREAM OF MOTORIZED DAMPER SHALL BE INSULATED TO BUILDING ENVELOPE R VALUES LINING WHERE INDICATED ON THE PLANS ENGINEER TO CONSIDER LINING WHEN VELOCITY IS 1,400 FPM OR GREATER SEISMIC SUPPORT PER APPLICABLE CODE / LOCAL JURISDICTION. SEE MECHANICAL SEISMIC SHEET WHEN APPLICABLE. _ IP = 1.0 IP = 1.5 (LAB PRESSURIZATION) NOTES 1, 2, 3, 4, 5 HVAC OA INTAKE LOUVER CAN / PLENUMS UPSTREAM OF MOTORIZED DAMPER SMACNA *2" GALVANIZED DUCT; GAUGE AND REINFORCEMENT SHALL BE SMACNA OR BETTER RECTANGULAR TO HAVE S &D CONNECTIONS, ROUND MAY BE SPIRAL ELBOWS: CENTERLINE RADIUS OF 1.5 DIA OR • MITERED 90S WITH VANES OR PURCHASED ADJUSTABLE ELBOWS IN ACCORDANCE WITH SMACNA +1" CL RADIUS OF 1.0 DIA ON DUCTS LARGER THAN 24" DIA TAPS: CONICAL OR BOOT -STYLE SPIN -IN / ATTO BRANCHES OK 3 -FOOT MAX LENGTH WITH NO OFFSETS; USE THERMAFLEX; GKM, OR EQUAL; FLEX AT EQUIP CONNECTIONS TO COMPLY WITH SMACNA APPLICABLE PRESSURE CLASS SMACNA SEAL CLASS LEVEL C FOLLOW BASIC "LEVEL A" SMACNA FOLLOW BASIC "LEVEL B" SMACNA FOLLOW BASIC "LEVEL C" SMACNA ENGINEER TO SPECIFY WITHIN CONDITIONED SPACE: NO INSULATION REQUIRED NOT WITHIN CONDITIONED SPACE: R-7 WITH APPROVED VAPOR/WEATHER BARRIER IN CONCRETE OR GROUND: R- 5.3 1" LINING ONLY WHERE INDICATED ON PLANS SEISMIC SUPPORT PER APPLICABLE CODE / LOCAL JURISDICTION. SEE MECHANICAL SEISMIC SHEET WHEN APPLICABLE. IP = 1.0 IP = 1.5 (LAB PRESSURIZATION) NOTES 1, 2, 3, 4, 5 HVAC RETURN LOW PRESSURE SMACNA -1/2" OR -1" PRESSURE NOTE: MCKINSTRY BUILDS ALL LOW PRESSURE DUCTWORK IN ACCORDANCE WITH +1" SMACNA GUIDELINES TO MAXIMIZE PRODUCTION EFFICIENCY CONDENSING BOILER FLUE PRESSURE STACK PER BOILER MANUFACTURER'S SPECIFICATIONS HEAT FAB SAFE T VENT, PVC HEAT FAB SAFE T VENT (BY SELKIRK), PVC N/A PER MANUFACTURER INSTALLATION INSTRUCTIONS FOLLOW BASIC "LEVEL B" SMACNA N/A INTEGRAL TO HEAT FAB SAFE -T VENT SEISMIC SUPPORT PER APPLICABLE CODE / LOCAL JURISDICTION. SEE MECHANICAL SEISMIC SHEET WHEN APPLICABLE. IP = 1.5 NOTES 1, 2, 3 NOTES: 1. ALL DUCTWORK TO BE FABRICATED IN ACCORDANCE WITH McKINSTRY DUCT CONSTRUCTION STANDARDS / SUBMITTALS WHICH MEET OR EXCEED SMACNA GUIDELINES 2. ALL DIMENSIONS SHOWN ON PLANS ARE INSIDE CLEAR DIMENSIONS. 3. THE MECHANICAL ENGINEER RESERVES THE RIGHT TO AUTHORIZE DEVIATIONS TO THESE STANDARDS TO ACCOMMODATE UNIQUE SITUATIONS AS APPLICABLE REVIEWED FOR CODE COMPLIANCE APPROVED. NOV 0 8 2012 City of Tukwila BUILDING DIVISION F p&p...18/ RECEIVED CITY OF TUKV/ILA OCT 10 2012 PERMIT CENTER For Th instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, . WA 98124 1 -800- 669 -6223 PROJECT: PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503-331-0234 www.mckinstry.com TUKWILA POOL POOL MODIFICATIONS 4414 SOUTH 144TH TUKWILA, WASHINGTON 98168 TENNIS COURT PARKING REGISTRATION: (Th TRACK POOL .,.� REVISIONS: 8/7/12 50% DD 9/4/12 75% CD'S 9/26/12 90% CD'S 10/8/12 PERMIT DRAWINGS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY CHECKED BY: JOB NUMBER:. DATE: SCALE: ENGINEERING ARLISS MERRELL TIM WHITE SETH DAVIS C10256 7/31 /12 AS SHOWN SHEET TITLE: EQUIPMENT SCHEDULES SHEET NUMBER: M7.2