Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG12-191 - SALAMA BUSINESS CENTER
SALAMA BUSINESS CENTER 15001 TUKWILA INTERNATIONAL BL PG12 -191 City o` Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431-3670 Inspection Request Line: 206 - 431 -2451 Web site: htta: / /www.TukwilaWA.gov • PLUMBING /GAS PIPING PERMIT Parcel No.: 0041000517 Permit Number: PG12 -191 Address: 15001 TUKWILA INTERNATIONAL BL TUKW Issue Date: 12/05/2012 Permit Expires On: 06/03/2013 Project Name: SALAMA BUSINESS CENTER Owner: Name: HENKLE FAMILY TRUST Address: C/O HENKLE DR & B J TRSTEE , 74 HOH PL 98257 Contact Person: Name: ABDIRIZAQ SMEIKOMAR Phone: 206 234 -3369 Address: 3515 S 146 ST #307 , TUKVVILA WA 98168 Email: Contractor: Name: OWNER AFFIDAVIT ON FILE Phone: Address: Contractor License No: Expiration Date: DESCRIPTION OF WORK: PLUMBING FOR TENANT: ADA RESTROOM AND HANDSINK Value of Plumbing /Gas Piping: $500.00 Uniform Plumbing Code Edition: 2009 Fees Collected: $207.38 International Fuel Gas Code Edition: 2009 Electrical Service Provided by: Permit Center Authorized Signature: �r u�.-c� crJr -mac Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions on the back of this permit. Signature: /97-,17/ I rI Z-4-4-63 Print Name: Date: ` c /�� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG12 -191 Printed: 12 -05 -2012 PERMIT CONDITIONS Permit No. PG 12 -191 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments. 13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. don: UPC -4/10 PG12 -191 Printed: 12 -05 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing /Gas Permit No. Qr '2_—\'\ Project No. 1 k'3 Date Application Accepted: 10 ' 2_ 17 Date Application Expires: 0 1 Z2v i2 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: 15001 Tukwila International Blvd Salama Business Center King Co Assessor's Tax No.: 1 co --o-S1 1 Suite Number: Floor: New Tenant: m Yes ❑..No PROPERTY OWNER ° Name: ' ,/ \ ' A j 1 L ¶YW Address: niC0V l 1 AU., City: /iaNm State: ,,J p- Zip: 0le1% Fax: CONTACT PERSON - person receiving all project communication Name: Abdirizaq Smeikomar Address: 3515 S 146 St #307 City: Tukwila State: WA Zip: 98168 Phone: (206) 234 -3369 Fax: Email: PLUMBING CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 500 Scope of Work (please provide detailed information): installation of plumbing for new tenant - ADA restroom and hand sink Building Use (per Intl Building Code). Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: H:\ApplicationsWorms- Applications On Line \2011 Applications\Plumbing Permit Application Revised 8.9.1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap 1 Sinks 1 Rain water system — per drain (inside building) 1 Grease interceptor for commercial kitchen ( >750 gallon capacity) Each additional medical gas inlets /outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory 1 Urinal 1 Water heater and /or vent 1 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet 1 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Print Name: Abdirizaq Smeikomar Day Telephone: (206) 234 -3369 Mailing Address: 3515 S 146 St #307 Tukwila WA 98168 City State Zip H: \Applications \Forms- Applications On Line\2011 Applications\Plumbing Permit Application Revised 8- 9.1l.docx Revised: August 2011 bh Page 2 of 2 \"'qs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: htto: / /www.TukwilaWA.eov RECEIPT • Parcel No.: 0041000517 Permit Number: PG12 -191 Address: 15001 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED Suite No: Applied Date: 10/22/2012 Applicant: SALAMA BUSINESS CENTER Issue Date: Receipt No.: R12 -03261 Payment Amount: $207.38 Initials: LAW Payment Date: 12/05/2012 02:53 PM User ID: 1632 Balance: $0.00 Payee: MOHAMED JAMA ASHOUR TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 217612 ACCOUNT ITEM LIST: Description 207.38 Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000.345.830 41.48 000.322.103.00.00 165.90 Total: $207.38 rinr. RAr. int -OR PrintMrt• 12-n5-7n12 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. G'GrZ -t� CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188. Permit Inspection Request Line (206) 431 -2451 (206) 431 -3670 Project: !(-,14 Type f Ins p Ai -A g \� Address: 1 5 O ( 7.1" Date Called: Special Instructions: Date Wanted. l0 f D.— (3 era. p. rn. Requester: Ph1on—e 4 N -2 ), 3 3... — Approved per applicable codes. Corrections required prior to approval. COMMENTS: of AA) c C.-10 1 CCY Inspector: Date: ( - •(3 • R C EINS TION FEE QUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 1r00t 'Cail:to schedule 'reinspection. ,14,•��- ,.,�,,,fv,n?.: ..a _ ..�v'1:':T�nr":iz..•.,d�'�,a- rc,. .s- .u._�...ayt:,,�..,.,.:'z^~'. INSPECTION RECORD Retain a copy with permit INSPECTION NO.. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 f6i'?, -Ili PERMIT NO. Project: �r. j Type of Inspection: g r Address: ( S' do 1 0--j Date Called: Special Instructions: Date Wanted:. 3 .- a.mp. .m. Requester: Pho a No: 7 Approved. per applicable codes. El Corrections required prior to approval. 3 COMMENTS: • ;S. o nib 4E-0 r Inspector :. A A it li _cam► f1 n, Date: 1 S -7 b ( 't. REINSPECTION FEE REQUIRED. tior to next inspection. fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro'ect p A'44 _,- c. Type of Inspection: C�raJ VI}O/k Address: I c 0 0 I 1.e Date Called: Special Instructions: ) j Q t�.S �.t0 r !!.V ! _J Lip Date Wanted:. °�a.m. / — (4 -- 3 p.m. Requester: Phone No: 4 —WI 23 (0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ( I < 71) a 0 g-- j e..r•5 Are 11.e Coh T° 1 U K( A << f" e M U.S a, Z 4 niJ:, "t1,..r:,,) ., rczo-P (7.) vq a itA aL.e Ra nAe k A. rer r- tt?e..,A ,c` — 6A -0 " ' T P : /3— J e__ .. 0 01 - r-t./ /2-0 b-f- - ) f A-r 1 S tom' o oc )-(L AA & or IAJ , f a r Inspector: Date: t4 ! 1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ABBREVIATIONS SYMBOLS ABV - ABOVE EXP - EXPANSION. EXPOSED LOC - LOCATION REF - REFERENCE. REFER ACOUS - ACOUSTICAL EXT - EXTERIOR PL - LIGHT POLE REINF - REINFORCED ACT - ACOUSTICAL CEILING TILE FA - FIRE ALARM • MACH - MACHINE REQ, REQ'D - REQUIRED ACP - ACOUSTICAL CEILING PAN. FD - FLOOR DRAIN MATL - MATERIAL RM - ROOM ADJ - ADJACENT,ADJUSTABLE FDC - FIRE DEPARTMENT CONNECTION MAX - MAXIMUM RO - ROUGH OPENING AFF - ABOVE FINISH FLOOR FE - FIRE EXTINGUISHER MDF - MEDIUM DENSITY FIBERBOARD RUB • RUBBER ALT - ALTERNATE FEC - FIREEXTINGUISHERCABINET MDO - MEDIUM DENSITY OVERLAY SBC - SEATTLE BUILDING CODE ALUM - ALUMINUM FFE - FINISH FLOOR ELEVATION MECH - MECHANICAL SC - SOLID CORE ANOD • ANODIZED FH - FIRE HYDRANT MED - MEDIUM SCHED• SCHEDULE, SCHEDULED ARCH - ARCHITECTURAL FIN - FINISH MET - METAL SDMH - STORM DRAIN MANHOLE ASPH - ASPHALT FLASH - FLASHING MFR - MANUFACTURER SECT - SECTION BLDG - BUILDING FND - FOUNDATION MN - MINIMUM SF - SQUARE FEET BLKG - BLOCKING FLR - FLOOR MIR - MIRROR SG - SAFETY GLASS BLW - BELOW FO - FACE OF MISC - MISCELLANEOUS SHT - SHEET BM - BEAM FOS - FACE OF STUD MO - MASONRY OPENING SIM - SIMILAR BO • BOTTOM OF FOW - FACE OF WALL MTD - MOUNTED SL • STREET LIGHT BOT - BOTTOM FR - FIRE RESISTIVE. FIRE RATED MTL - METAL SM - SMALL BRG - BEARING FT - FOOT, FEET (N) - NEW SPEC - SPECIFICATION CAB - CABINET FT - FIRE TREATED NA - NOT APPLICABLE SO - SQUARE CB - CATCH BASIN FTG - FOOTING NIC • NOT IN CONTRACT SS - SANITARY SEWER CIP - CAST IN PLACE FURR - FURRING NO - NUMBER S.ST. - STAINLESS STEEL CJ- CONTROL JOINT GA - GAGE NOM - NOMINAL STD - STANDARD CL - CENTERLINE GALV - GALVANIZED NTS - NOT TO SCALE STL - STEEL CLG - CEILING GC - GENERAL CONTRACTOR 0/ - OVER STRUSTRUC - STRUCTURAL CLR - CLEAR GLS - GLASS O.C., o/c - ON CENTER STM - SYMMETRICAL CMU - CONCRETE MASONRY UNIT GRD - GRADE. GROUND OD - OUTSIDE DIAMETER SV- SHEET VINYL COL - COLUMN GV - GAS VALVE ODR - OVERFLOW DRAIN TBD - TO BE DETERMINED CONC - CONCRETE GWB - GYPSUM WALL BOARD OH • OPPOSITE HAND TEL - TELEPHONE CONST - CONSTRUCTION GYP - GYPSUM OPN'G - OPENING TG - TEMPERED GLASS CONT - CONTINUOUS HB - HOSE BIB OPP- OPPOSITE TO -TOP OF CPT - CARPET HC- HANDICAP PERP - PERPENDICULAR TS - TUBE STEEL CT - CERAMIC TILE HD - HOT DIPPED PL - PLATE TSP - TELEPHONE SERVICE POLE CTR - CENTER HDWR - HARDWARE PLAM - PLASTIC LAMINATE TYP - TYPICAL DET, DTL - DETAIL HGT - HEIGHT PLT - PLATFORM UL - UNDERWRITERS LAB. OF - DRINKING FOUNTAIN HM - HOLLOW METAL PTD - PAINTED UNO - UNLESS NOTED OTHERWISE DIA - DIAMETER HORIZ - HORIZONTAL PNT - PAINT UON - UNLESS OTHERWISE NOTED DIM - DIMENSION HPC - HIGH PERFORMANCE COATING PP • POWER POLE VIN - VINYL DN - DOWN HR - HOUR PSF - POUNDSPERSQUAREFOOT VB - VINYLBASE DS - DOWNSPOUT ID - INSIDE DIAMETER PSI - POUNDS PER SQUARE INCH VCT - VINYL COMPOSITION TILE DW - DISHWASHER INSUL - INSULATION P.T. - POST TENSIONED VERT - VERTICAL DWG - DRAWING - INST - INSTALL. INSTALLER PT - PRESSURE TREATED VIF - VERIFY IN FIELD (E). EXIST - EXISTING INT - INTERIOR PV • PLUMBING VENT WI- WITH EA • EACH JAN - JANITOR PWD/PLYWD - PLYWOOD WD - WOOD EF - EXHAUST FAN JT - JOINT RAD - RADIUS WIN, WDW - WINDOW EJ, EXP JT - EXPANSION JOINT LAM - LAMINATED RB - RUBBER BASE WNST - WAINSCOT ELEC - ELECTRIC(AL) LAV - LAVATORY RCP - REFLECTED CEILING PLAN WP - WATERPROOF ELEV- ELEVATION ORELEVATOR LB - POUND RD - ROOF DRAIN WR - WEATHER RESISTANCE EO - EQUAL LG - LARGE REC - RECOMMENDED WT•WEIGHT 1 ELEVATION INDICATOR BUILDING SECTION INDICATOR WALL SECTION INDICATOR DETAILIENLARGED PLAN INDICATOR PARTIAL ELEVATION INDICATOR DATUM ELEVATION GENERAL NOTES 1. ALL WORK SHALL CONFORM TO THE 2009 INTERNATIONAL BUILDING CODE AND AS AMENDED BY ANY LOCAL BUILDING CODES OR ORDINANCES. INCLUDING 2009 WASHINGTON STATE ENERGY AND 2003 ACCESSIBILITY CODE REQUIREMENTS. 2. DO NOT SCALE DIMENSIONS FROM DRAWINGS. VERIFY ALL DIMENSIONS. DATUMS, AND LEVEL PRIOR TO CONSTRUCTION. ALL DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE UNLESS NOTED OTHERWISE. CONSULT WITH ARCHITECT AND OWNER REGARDING ANY SUSPECTED ERRORS. OMISSIONS. OR CHANGES ON PLANS BEFORE PROCEEDING WITH THE WORK. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED SAFETY PRECAUTIONS AND METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM THE WORK. 4. THE CONTRACTOR SHALL UTILIZE CONSTRUCTION TECHNIQUES, PRACTICES, AND PROCESSES THAT ARE STANDARD AND ACCEPTABLE TO THE CONSTRUCTION INDUSTRY QUALITY STANDARDS. THE ARCHITECT /DESIGNER DOES NOT SPECIFY OR ASSUME LIABILITY OR RESPONSIBILITY FOR METHODS AND MEANS OF CONSTRUCTION. 5. THE CONTRACTOR SHALL INDENIFV AND SAVE THE OWNER ARCHITECT/DESIGNER 6 OWNERS REPRESENTATIVE HARMLESS FROM AND AGAINST ANY DAMAGE, COST, OR LIABILITY FROM INJURY OR DEATH TO PERSONS OR FOR DAMAGE TO PROPERTY CAUSED BY NEGLIGENCE OF THE CONTRACTORS, HIS EMPLOYEES. AGENTS. AND/OR SUBCONTRACTORS. 0. THE CONTRACTOR SHALL EXAMINE THE PREMISES TO DETERMINE THE EXTENT OF WORK AND THE CONDITONS UNDER WHICH IT MUST BE DONE. 7. THE CONTRACTOR SHALL CHECK AND VERIFY CONTRACT DOCUMENTS AND FIELD GONOIDONS FOR ACCURACY AND CONFIRM THAT THE WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. THE CONTRACTOR IS TO OBTAIN CLARIFICATION FROM THE ARCHITECT/DESIGNER BEFORE PROCEEDING WITH TI-10 WORK IN QUESTION. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIRS OF ANY ACCIDENTAL DAMAGE HE/SHE HIS/HER EMPLOYEES INFLICTS UPON THE EXISTING WORK TO REMAIN. IF. FOR ANY REASON, DAMAGE TO EXISTING WORK OR UTILITIES IS CONSIDERED TO BE UNAVOIDABLE. SUBMIT WRITTEN NOTIFICATION OF THIS BEFORE SIGNING THE CONTRACT. IN THE ABSENCE OF SUCH NOTIFICATION. THE CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR DAMAGE AND THE COST OF SATISFACTORILY REPAIRING OR REPLACING THE DAMAGED WORK. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL AND PROPER DISPOSAL OF ALL DEBRIS FROM THE WORK AREA DURING PROGRESS OF THE JOB. DPD PROJ. No. SALAMA BUSINESS CENTER OFFICE REMODEL CONTACTS OWNER REP: ABDIRIZAO SHEIKOM 206 - 234 -3369 ARCHITECTURAL DESIGNER SAM SAROEUM 206 - 650-6321 SHEET INDEX DRAWINGS CV1 COVERSHEET A1.00 SITE PLAN pv nn SMlCrnur CI nn° 01 01 A3.00 PROPOSED FLOOR PLAN A5.00 • PLUMBING DIAGRAM PROJECT INFORMATION FILE COPY Perrrtlt E ©.,VG I, PI ^" r -..yew approval is subject to errors and orris ehns. of construction documents does not authrs ti =oi } „lily adopted code or ordinanc5. Recd :pt Fiz :d Copy and conditions is acknowledgd: B Date: City Of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. sv:sions will require a new plan submittal may ins :ude additional plan review f?a<,. SEPARATE PERMIT REQUIRED FOR: Wi Aechanical Qoelectricai ❑ Plumbing Reas Piping of Tukwila i `r`'_ -G DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED DEC 04 2012 A's � City of Tukwila BUILDING DIVISION PROJECT LOCATION LEGAL DESCRIPTION TYPE OF CONSTRUCTION BUILDING SF NUMBER OF OCCUPANTS TYPE OF OCCUPANTS DESCRIPTION OF WORK APPLICABLE CODES 15001 TUKWILA INTERNATION BLVD TUKWILA, WA98188 PARCEL I.D. 0041000517 COMMERCIAL BUILDING 1186 SF 1000 SF /36= 27 TOTAL OCCUPANTS BUSINESS (GROUP B) REMODEL INTERIOR SPACE FOR OFFICE USE ADD 3 OFFICE ROOM 2009 INTERNATIONAL BUILDING CODE 2003 ADA ACCESSIBILITY CODE 2009 WASHINGTON ENERGY CODE RECEIVED CITY OF Tumili A, OCT 222012 PERMIT CENTER P(illH'1I REVD DESCRIPTION DATE c;c> L2.1 1 REVISED FLOOR PLAN PER OWNER REQUEST 9/142012 PER CITY OF TUKWILA COMMENTS 10/15/2012 COVER SHEET PRELIMINARY 9/11/2012 CONSTRUCTION REVISED 10/15/2012 DESIGN DRAWN CHECK PLOT DATE 265.2 + PROPERTY LINE 7 SCALE: 1:200 S 150TH STREET PARKING AREA WHEEL CHAIR ACCESSIBLE PARKING 133.8,, PROPFRTV VIEWED FOR E COMPLIANCE APPROVED • DEC 0 4 2012 City of Tukwila BUILDING DIVISION RECEIVED . CITY OF TUKVR . A OCT 222012 PERMIT CEi4TER PROJ. No. SALAMA BUSSINESS CENTER OFFICE REMODEL SITE PLAN Mr' 9' -6" EXISTING _ NEW OFFICE #3 OFFICE BREAK REVISED i';' F,. CV ., RES STORAGE AREA ,, SUPPLY AREA AREA - 10' -4 "x 11-0" ,.`OOM SEE ,.� • . IL 2/A3.00 8'-11"x 9' -2" 1 C° (N) HAND SINK � tA A3.00 ^ r / 1 _ �, / 1 N / 3 NEW OFFICE #2 8'x5' OUBLE PANEL GLAZIN— G �/ \ \3.00 4� I \ WINDOW INSTALL BY CONTRACTOR \s.o� 1_ 11 3 7 1_ 4 " 9 9' -0 "x 9' -2" - M '_ " 1_ 11 10'-8" / 7 10 6 8 f / / / \ OPEN OFFICE AREA _ 548 SF – r6 NEW OFFICE #1 A3.00 ,N,3.(1)(' 9' -0 "x 9' -2" REV# DESCRIPTION DATE (E) L REVISED FLOOR PLAN PER OWNER REQUEST 9/14/2012 X22. PER CITY OF TUKWILA COMMENTS 10/15/2012 DOOR ENTRY \ m – TAPE & JOINT COMPOUND (TYP 5 3" METAL STUDS (TYP.) 0-r CONNECTION DETAIL PROPOSED FLOOR PLAN SCALE: 1/4"=1' REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 4 2012 City of Tukwila BUILDING DIVISION ONOT USED L2A po ir Nialv NS/ XISTING WALL 3" MEDAL STUD 1/2" GYP. BD. 4" 1/2" GWB (WALL) 2x3 STUD WALL @ 16 O.C. (TYP.) ALL INTERIOR W R -13 INSULATION AMA BUSINESS CENTER INTERIOR WALL DETAIL VENT GRAB BAR 32" MIN. CLR. " MIN. AD OADA RESTROOM LAYOUT (2003 ADA CODE) SCALE: l4 •1' 8D NAIL AT ALL FRAMING (TYP.) RECEIVED CITY OF TUKWILA OCT 2 2 2012 PERMIT CENTER �r 0 NEW WALL TO EXISTING WALL DETAIL 0 90° CORNER DETAIL CORNER BEAD PROPOSED FLOOR PLAN PRELIMINARY PERMIT 9/11/2012 CONSTRUCTION REVISED 10/15/2012 7 / WH _1/2" LAV ly WC CV / / Norte • ¢JDre$lo /1'1'X42 ! ar is l ci- fps,,. -St -kit Neek.0 . r -4- r`ofsCor►r►tcf/p'" pot 4;lIC4, S 0 zo > 0 P \ WASTE CO (1 2 13 i WASTE CO ti• ti e WC IAN �O 4 � • i a WATER SUPPLY AND DISTRIBUTION ISOMETRIC PLAN O DRAIN/WASTE AND VENT ISOMETRIC PLAN Z 2 SCALE N.T.S. SCALE: N.T.S. WC o-- — 7 11 I I o Si OWA ER SUPPLY AND DISTRIBUTION PLAN SCALE: 3 w X WASTE CO S O LAV O WASTE CO REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 4 2012 LAV WC City of Tukwila UIL' ING -' IVIS ON DRAIN/WASTE AND VENT PLAN # FITTING TYPE SIZE FIXTURE SERVED 1 T REGULAR 3" TOILET 2 T REGULAR 3" SINKNENTING 3 90° ELBOW 3" SINK 4 WYE REDUCER 3" TO 2" SINKNENT 5 90° ELBOW 3" LAV SINK 6 90° ELBOW 3" LAV SINK 7 90° ELBOW 3" LAV SINK 8 WYE REDUCER 3" TO 2" LAV SINK 9 WYE REDUCER 3" TO 2" TOILET 10 90° ELBOW 2" VENTING 11 Y REGULAR 2" VENTING 12 CLEANOUT TEE 2" CLEANOUT 13 T REGULAR 2" VENTING LEGEND WH - WATER HEATER NOTES: WC - TOILET 1. VERIFY ALL LINE LOCATION CO - CLEAN OUTS PRIOR TO CONNECTION. LAV - LAV SINK 2. MUST MEET ALL APPLICABLE 2009 HW - HOT WATER UPC, IRC & IBC CODE REQUIRMENTS CW - COLD WATER 3. HORIZONTAL DRAINAGE BELOW S - HAND SINK FLOOR SLOPE =1/4" MIN. FD - FLOOR DRAIN VTR - VENT THRU ROOF POC - POINT OF CONNECTION 60" MIN. CLR. 0 z CD 7' -10" \,,- / I 1 I 1 GRAB BAR SCALE 316,1'-0' ADA RESTROOM CALE: 1/2~1'-0' N DPD PROJ. No. SALAMA BUSINESS CENTER OFFICE REMODEL 1500 TUKWILA INTERNATIONAL BLVD. TUKWILA, WA. 9818 )2" 42" MIN./ 32" MIN. I,5 -'0" MIN ADA/ CLR. T 2003 DA COD P ) Jl CO / LTR# L2.1 PLUMBING DIAGRAM Tvn NOV 2 7 2012 R PRELIMINARY NOT FOR CONSTRUCTION REV# DESCRIPTION DATE REVISED PLUMBING DIAGRAM PER CITY COMMENTS 11/9/2012 OWNER REVISED SINK & TOILET LOCATION 11/9/2012 0 REVISED PER CITY COMMENTS LETTER #2 11/21/2012 7,121b 06 -03 -2013 city of Tukwila Jirn Haggerton, Mayor Department of Community Development Jack Pace; Director ABDIRIZAQ SMEIKOMAR 3515 S 146 ST #307 TUKWILA WA 98168 RE: Permit No. PG12 -191 SALAMA BUSINESS CENTER 15001 TUKWILA INTERNATIONAL BL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 07/16/2013. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 07/16/2013, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, P„,W 7-1 Bill Rambo Permit Technician File: Permit File No. PGI2 -191 6300 SOuthcenter Boulevard, Suite #100 • Tukwila, Washington 9188 • Phone 206- 431 -3670 • Fax 206-431-3665 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director November 14, 2012 Abdirizaq Smeikomar 3515 S 146 St, #307 Tukwila, WA 98168 RE: Correction Letter #2 Plumbing /Gas Piping Permit Application Number PG12 -191 Salama Business Center —15001 Tukwila International BI Dear Mr. Smeikomar, This letter is to inform you of corrections that must be addressed before your plumbing/gas piping permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Public Works Department has no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have any questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Jenn fer Marshall Permit Technician File: 'G12 -191 W:\Perrnit Center \Correction Letters \2012\PG12 -191 Correction Letter #2.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: November 14, 2012 Project Name: Salama Business Center Permit #: PG12 -191 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The revised plumbing plan needs more specific details for the way the drain and vents are run. The vent from the sink shows running into the 3" drain. The sink drain shows running sideways into the 3" waste with a vent off to the side indicating all underground connections. Please pay close attention as to how the drain and waste lines are drawn on the plumbing handouts. Example where the sink drain shall be connected to a "WYE" fitting where the vent goes up and drain goes down to the main drain. Also the #4 joint is not the same for the 2" vent shown. Revise the Table to show the specific fittings as they are indicating tee reducers from 3" to 2" Y, 2" elbows and so on. 2. Show cleanouts as required on the plan view and isometric drawing. (2009 UPC 707.4) 3. Show on the plan view Point of Connection for the water supply. 4. Enclosed is a sample of plumbing diagrams required with parts schedule table on the sheet. Should there be questions concerning the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. ck• City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director October 24, 2012 Abdirizaq Smeikomar 3515 S 146 St, #307 Tukwila, WA 98168 RE: Correction Letter #1 Plumbing /Gas Piping Permit Application Number PG12 -191 Salama Business Center —15001 Tukwila International BI Dear Mr. Smeikomar, This letter is to inform you of corrections that must be addressed before your plumbing/gas piping permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Public Works Department has no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have any questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. encl File: PG12 -191 W:\Permit Center \Correction Letters\2012\PG12 -191 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Tukwila Building Division Allen Johannessen, Plan Examinerr Building Division Review Memo Date: October 24, 2012 Project Name: Salama Business Center Permit #: PG12 -191 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide a revised plumbing plan that shows drain waste vent isometric diagram and floor plan view pipe diagram separate from the water supply diagrams. Specify the sizes of each pipe and identify type of fittings for change of direction of pipe. Show vent pipes that vent to the outside. Show all required cleanouts. Identify point of connection. (2009 UPC Chapter 7 & 707.0) 2. Provide a revised plumbing plan that shows water supply pipe isometric and floor plan diagrams separate from the drain waste vent diagrams. Pipes shown indicate 2" supply pipes and 8" pipes from the water heater which is not a correct sizing for those supply lines. Specify correct pipe sizes of each supply pipes for hot and cold. Identify point of connection. 3. Enclosed is a sample of plumbing diagrams required with parts schedule table on the sheet. Should there be questions concerning the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. OPERINIi COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG12 -191 DATE: 11/27/12 PROJECT NAME: SALAMA BUSINESS CENTER SITE ADDRESS: 15001 TUKWILA INTERNATIONAL BL Original Plan Submittal X Response to Correction Letter # 2 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: fulling [vision Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete V1 Incomplete ❑ DUE DATE: 11/29/12 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS ROUTING: Please Route 11 Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ DUE DATE: 12/27/12 Approved with Conditions tW Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ItER COii COP. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG12 -191 DATE: 11 -09 -12 PROJECT NAME: SALAMA BUSINESS CENTER SITE ADDRESS: 15001 TUKWILA INTERNATIONAL BL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS Bffng Division Fire Prevention Planning Division Public Works ❑ Structural ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -13 -12 Complete iy] Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route ISJ Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12 -11 -12 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 11 1 1/ Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 aPERMIT COORD COP* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG12 -191 DATE: 10/22/12 PROJECT NAME: SALAMA BUSINESS CENTER SITE ADDRESS: 15001 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Bui ing'Dlvision .14 l 1`�+ Public Works no Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10/23/12 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route X Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/20/12 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg is Fire ❑ Ping ❑ PW ❑ Staff Initials: CitAbf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan ChecWPermit Number: ❑ Response to Incomplete Letter # 1 Response to Correction Letter # JP- ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person: "9 4ln ,'7 Summary of Revision: Phone Number: A,t,RECEnft 2 72012 'ERMl1 eFM'EA Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: / / Entered in Permits Plus on H:\Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Revision Submittal.doc Revised: May 2011 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.TukwilaWA.sov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 11/09/2012 Plan Check/Permit Number: PG12 -191 Response to Incomplete Letter # I Response to Correction Letter # 1 Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: SALAMA BUSSINESS CENTER. Project Address: 3515 S 146TH ST#307 TUKWILA. WA 98168 Contact Person: ABDIRIZAQ SMEIKOMAR Phone Number: (206) 234 -3369 Summary of Revision: 1.) PROVIDED PLUMBING DIAGRAM AND ISOMETRIC DRAINAGE WITH SIZES OF PIPES WITH FITTING 2.) PROVIDED PLUMBING DIAGRAM AND ISOMETRIC OF WASTENENT WITH SIZES OF PIPES FITTING 3.) RELOCATED THE SINK AND TOILET, SEE SHEET A5.00. Sheet Number(s): A5.00 .. °• ;3�vVll.p NOV .092012 PERMIT CENTER "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on H ;Applieat ionc:Fomis- Applient ion. On Line ?010 Applies' inn. ,7 -7010 - Re%i.ion Submine Woe Revised: 11av 2011 • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -367o FAX (206) 431 -3665 E -mail: tukplanpci.tukwila.wa.us Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 -0179 Planning Division 206 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING ) /913 D R ,' Q.S//E/ko,n -R [please print name] , states as follows: PERMIT NO: T6 /� 6/ 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number /3 , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. )6D,w ; z 'Tc7 Owner /Owner's Agent* Signed and sworn to before me this day of cErYl 6e /' , 20 0 ARY PUBLIC in and for the State of Washington Residing at ilt , County dtOrie Ds'-a9 -/y Name as commissioned: My commission expires: 18.27.090 Exemptions. The reg tion provisions of this chapter do not apply to. 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who holdsra' valid' electrical contractor's license under chapter;19.28.RCW that.employs a certified journeyman electrician, a certified•reside`iitial specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally 'directly, and;immediately appropriate to thie'like ;in -kind replacement of a household appliance or other •smallliouse. lio. ldu;t ilization equipment that requires limitedelectc,pwer and limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions.