Loading...
HomeMy WebLinkAboutPermit PG12-195 - EXPRESS SHOPEXPRESS SHOP 458 SOUThCENTER MALL PG12 -195 Parcel No.: Address: City otkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov PLUMBING /GAS PIPING PERMIT 9202470010 458 SOUTHCENTER MALL TUKW Project Name: EXPRESS SHOP Permit Number: Issue Date: Permit Expires On: PG12 -195 12/12/2012 06/10/2013 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 HARDEEP SINGH 2818 144 PL SW , LYNNWOOD WA 98087 HSINGH86 @HOTMAIL. C OM Phone: 425 - 268 -2088 PETER HAMMER CONSTRUCTION LLC Phone: 206 -769 -1280 Address: 15409 30 AV S , SEATTLE WA 98188 Contractor License No: PETERHC907DK Expiration Date: 03/12/2014 DESCRIPTION OF WORK: ADDING TWO FLOOR DRAINS, MOP SINK, 3 COMPARTMENT SINK, HAND SINK, CONNECTING TO THE EXISTING MALL PLUMBING. ALSO WATER HEATER. Value of Plumbing /Gas Piping: Fees Collected: Electrical Service Provided by: Permit Center Authorized Signature: $3,800.00 Uniform Plumbing Code Edition: 2009 $165.69 International Fuel Gas Code Edition: 2009 Lail PI Date: I d— (0 — 62_ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: p This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. /Inn. I IPr -4/1 f1 P(,12 -1451 PrintArl. 12 -12 -2017 • • PERMIT CONDITIONS Permit No. PG 12 -195 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. rinr`• IIPC -4110 P(119 -195 Printprl• 19- 19_9(119 CITY OF TUKWI • Community Developm epartment Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 Iittp: / /www.TukwilaWA.gov Plumbing/G. _ Project No. Date Application Accepted' Date Application Expires: (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: LASS 5c'5 1 Leo T `1 - M�OLI, Tenant Name: �^E -p20.SS King Co Assessor's Tax No.: Suite Number: \ S&O PROPERTY' OWNER Name: Llesi f lrc 0 Address: `fig 00 SoV'jH Le p16-12 Y() 1°4-t-- City: --r U R ill State: \,.11, Zip: q 8, re CONTACT PERSON - person receiving all project communication . . .. Name: Y`e,?p 1P 'I 14(4H Address: ns ,g 1�,m Qi Sirs City: Li >N lj kr_rboc, State: �,.,.(1 Zip: .ig 037 Phone: L 33 Fax: Email: %61nyi g6 1.-\o-Trryfo t- - Cam Floor: New Tenant: Yes O.. No PLUMBING CONTRACTOR INFORMATION:. Company Name: pc-cc.Q. 1 , Address: \ suvoci t3 PEE S City: Se,Q -s-vLe State: L�.rp% Zip: Cig148 Phone:. ,.3_I _Z52i Fax: Contr Reg No.:.PeZ021-1 C e ffi Exp Date: 631 I DK j Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 800 p O Scope of Work (please provide detailed information): Pi D9v.rt(A T�,,:m Fuc chq 2uA 1 n1S N' 3 - co me S 0.0.< , f\Ne►0 t,.rIAS -1 t v4 l.& J CO Ec T l 4 L. —1-7 7,-0 71-+ S m14LL Pl vr-lgiii-IEt4 f'(.J' Tc GZ -E(ktC R Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: H:\Appltcattons \Forms - Applications On Ltne\201I Appltcattons\Plumbtng Permit Application Revised 8 -9 -I l.docx Revised: August 2011 bh Pagel of 2 Indicate type of plumbing fixtures and/oilv piping outlets being installed and the quanti Fixture Type Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks 3 Rain water system — per drain (inside building) Grease interceptor for commercial kitchen ( >750 gallon capacity) t, Each additional medical gas inlets /outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) • Fixture Type Qty • Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and /or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 low: Fixture Type • _ .? ._ , ,: - .. _.. °Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type • . • Qty " Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED ENT: Signature: \04)`4 Print Name: 1R pQ c ' eritoi Mailing Address: \'• \ c)\- ,s1t.) H:\Applications\Forms- Applications On Line\2011 Applications\PIumbing Permit Application Revised 8 -9 -1 I.docx Revised: August 2011 bh Date: \ Day Telephone: -c)--E '—) r) Ce City State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: PG12 -195 Address: 458 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 11/05/2012 Applicant: EXPRESS SHOP Issue Date: Receipt No.: R12 -03045 Payment Amount: $165.69 Initials: WER Payment Date: 11/05/2012 11:38 AM User ID: 1655 Balance: $0.00 Payee: SEATTLE HOLDINGS GROUP INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 0999 165.69 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000.345.830 33.14 000.322.103.00.00 132.55 Total: $165.69 rinr: Rerpint -ns PrintMri• 11- n5 -7n19 INSPECTION NO.. '1) 'F • INSPECTION RECORD Retain a copy with permit PERMIT NO CITY OF TUKWILA BUILDING DIVI 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 ;ION (206) 431 -3670 Project._ PV'AD r S S S LtJ p Typ nspecton: PI; , Al ! J • Address: ' 1 ,{ Date Called: Special. Instructions: Date Wanted:. — r / 3 /a.m. . .m. Requester: Phone No: 2,S '- a -- 0F s- Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: a A)n ,4y..,,,,, 1;.pp,ivvi J v, 4 00,70,- / C f• o l //® /,,- r , , s ' � 1 Inspector: -fir` Date: /— /7 FA/INSPECTION FEE REQUIRED. Prioro next inspection. fee must be paid at 6300 Southcenter'Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PG1z -lvs PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: ( a 5 e or Type of Inspection: DO Address: Date Called: Special Inst uctions: Date Wanted:. a.m. p:m. Requester: Phone No: : Approved per applicable codes. MCorrections required prior to approval. COMMENTS: - ,Jrn- Lis( ��I (L . !o JDv i i5 s Prole pop-Btu/ Inspector: 6E.A067,\ Date: I I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must her paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule:reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Ci 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36701 Permit Inspection Request Line (206) 431 -2451 Project: r/ pfe s $ A ? Tpeof Inspection: yle-6 J Co(t •k L J/ Addressi' P: ��DJ/ 5X Date Called: Special Instructions: -4 r)re-xf:e :7-----iu eircepr-of f Date Wanted:. / -Z. - ' / - cam- 4 ''` [ 2___— . P.m. Requester: Phone /N�o: % � t„f)U � � 917 t r) � 1 0 Approved per applicable codes. ElCorrections required prior to approval. s COMMENTS: / (1-. /L W-) ��A,,ta pr , AA US ff r- ��DJ/ 5X -4 r)re-xf:e :7-----iu eircepr-of No-7---- It/ S q d L.7 r{-X " 'Li U1 1.-\. J (c- Inspec or: C, Dater REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 Project: ?.--Kr e_s< s iv o i) Typg of Inspection: I(' 0 0(9 (J)\ 1\ (.-T r-ki 6 /\---ilk uiS - -.1-- LA i \ P 0 Address: ' 45 5 C. 44,(Mi Date Called: ( ) f) e_c. AALST-- b-e Att-/-4-.-6.&.- , Special Instructions: Date Wanted: I.--.- .KbrInl. Requester: , . Phone No: ?Dfr 2-0 —q 777 (7. 1=1ApproVed per applicable codes. rrections required prior to apprOval. COMMENTS: , . (J)\ 1\ (.-T r-ki 6 /\---ilk uiS - -.1-- LA i \ P 0 c-.> -T-0 445 ot&_,D(C_X—r__ 1 r■,S n c; I I ----.N 7 , -, - • ( ) f) e_c. AALST-- b-e Att-/-4-.-6.&.- , VZ____ 0 A c C-10---- .--e kj,c-)■ --- ‘■---t— ‘s___C 0 p L > . k i e 7. A .....___ . 4W('‘. :9,:,. . ..-, . ( to-e At ce,;.I (0 A ( _ef\j---er e_kfe_EN, Co f )eAA.AzT-5-0..ST-bo AM r -r-v 4 e'.11,..r ()A-:-S«) rei 17ecroT"- k A A Date: "" r7 REINSPECTION FEE REQ;11.F'riornext inspection..fee.mustbe: : paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection'.- •••,-6'r Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO.. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: c 0�e" s Type r f Inspection: (0(),« :1--A./ A-2. Addreessss: �j�/ �T < (c S e t Jul{ r Date Called: Special Instructions: 1 Date Wanted:. Requester: Phone No: _ -- -- CGS �~-� ( !19'x• /:_ 0 Approved per applicable codes. • Corrections required prior to approval. COMMENTS: e ID ( z) iJ e..Q .p 6 eS JA S r AA r �i J X 5-6 r 45- Inspector: Date: n REINSPECTION FEE R QUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION -C' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 PO lei s Project: : Press st, p Type of Inspection: 6 ro JAL war Ad ess: Date Called: Special Instructions: Date Wanted. i •Z -( 3'i) (_- `� me P.m. Requester: PhleCtilo ! Approved per applicable codes. El Corrections required prior to approval. COMMENTS: r `)Clioi ! 1/1 /NW1 3 .0 ill Le. . i� Insp(ctor: �NL Date: r7 REINSPECTION FEE REQUIRE . for to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �• ..�.t ...1 ....w -4& 3_-'�` * .'�. ^�!Yl'-rt f1_ fl. '- .-' .. f.��4' ._._ i.-_. wnYV -.`�� FILE COPY P r e t„ GREASE . gitictf-gt4+ gg oi-vieti I -- GEMEN Grease Interceptor 1..1•••0:, i‘ird c+.••'..--.'11:•• ic : • riPce';sed Silicone Seal st- The iD , • ti„,°: • gtf' t iiti to grease management • . Einolai:fi4nftf:4 theralopgasilgcs, (0 4, , Coo, chbfl OPA ev en mdey the al orig. st..=,%vr.,.-%i.T. in41; ca . ions = A Td • Compact, durable, user-friendly solution • Molded one piece tank eliminates seams-andpoteritial leaking • Can withstand continuous discharge at 104° C (220° F) 1-,;LightWeightand,strong,.Endure' Models weigh up to 60% less ,than directly equivalent metal 'competitors. offerS-easeof ins_ and Storage Endure' supports pedestrian and lic • Connected using • couplings allowi • piping materials • Flexibility of insta installed in-floor, semi-recessed -alktotwErt FOR ODE •MPLIANCE P.4 - OVED ht dutrtr • ‘s, 7TOrhiaiDOZas 2012 c_pn b 01 Tukwila BUILDING DIVISION ASME A112.14.3 NYe •:„ 7,9 MEA 160-08-E <57.1(771 ;7') r47.' •.•'°1 www.enduraintercenEGERED CITY OPTUKWILA NOV 0 5 2012 PERMIT CENTER ' Diffuser baffle only used in 35 and 50 GPM models Grease Interceptor Contractor shall install a Canplas Endura0 Grease Interceptor, Part No. (fill in). A flow control with a rate of gpm will also be installed in accordance to manufacturer's instructions. The unit shall be comprised of engineered thermoplastics to withstand operational temperatures up to 220 °F (104 °C) and incorporate a lid with the capability of supporting 440 lbs. (200 Kgs). The unit will be supported by a 10 year manufacturer's extended warranty. The grease interceptor shall be certified to the current version of the PDI- G101standard and where locally applicable to A5ME112.14.3 or have UPC listing. Contractor shall provide mechanical connectors to connect the grease interceptor. TANK DIMENSIONS GPM /Ibs 15/30 20/40 25/50'L0 `2S/50 • 35/70 50/100 A 14.5" (368mm) 23.6" (600mm) 31.0" (787mm) 23.6 "(600mm) 31.0 "(787mm) 31.0" (787mm) B . 17.5 "(444mm) 17.5 "(444mm)23.5" (597mm) 17.5 "(444mm) 23.5 "(597mm) 23.5" (597mm) C 3.5" (89mm) 3.5" (89mm) 4" (102mm) 4.1 "(104mm) 5.0" (127mm) 5.0" (127mm) D 12.8" (325mm) 12:8" (325mm) 7" (178mm) 12.2 "(310mm) 12.5 "(318mm) 18.5" (469.9mm) E 16:3" (414mm) 16.3" (414mm) 11' (279mm) 16.3" (414mm) 17.5 "(444mm) 23.5" (596.9 mm) FLOW CONTROL DIMENSIONS Connection Iron Pipe Size (Solvent weld) 2 "hxh 3 "hxh 4 "hxh A 3.0" 4.23" 6.13" (81mm) (76.2mm) (107.4mm) (155.7mm) B 3.84" 5.93" 6.84" 2.27" (97.5mm) (151mm) ._ (173.7mm) (69.1mm) Operating Temperature Capabilities 220'E (104*() '220'F(104'C) °WAC:°. 'IE$ AIR INTAKE DIMENSIONS 2 "spgx h 3 "spg.x h 4 "spg-x h 2.91" 2.67" 3.19" (73.9mm) (67.8mm) (81mm) 2.71" ' 4.01" • 5.04" (68 :8mm) (1019mm) (128mm) 2.24" 2.27" 2.72" (56mm) (57.7mm) (69.1mm) FLOW CONTROL AIR INTAKE TEE "VERSION ILLUSTRATED US Gallons Per Minute (GPM) , 15 20 25,LO 1-'' ',� 25!: 35 50 CAPACITY- Pounds 30 40 50 50 70 100 Litres Per Second (LPS) 0.94 126 1.6 ' 1:6 ,. 22 • 3.2 CAPACITY - Kilograms 13.6 18.1 22.68 22.7 31.8 45.4 Average Efficiency % (ASME 112.4.3) 92.0% 95.4% 97.1% 92.5% 98.6% 93.9% Part Number 3915A02C ,. 3920A02 3925A02101 3925A03 (3") '_'3935A03 (3') ' ? :3935A04 (4") 3950A03 (3") 3950A04 (4 ") Grease Capacity Ibs (Kg) actual 34.8 (18.4) 76.4 (34.65) 53.4 (24.22) 74 (33.6)* 138.5 (62.8) 122 (55.3) " Operating Temperature Capabilities 220'E (104*() '220'F(104'C) iy220'F'(104'f): 220F(104'0 ,220F(104'C) 2201 (104'C) Surface Load Capacity 440 Ibs (200 kgs) 440 Ibs (200 kgs) 440 Ibs (200 kgs) 440 Ibs (200 kgs) 440 Ibs (200 kgs) 440 Ibs (200 kgs) Unit Weight (Empty) 15.8 Ibs (7.17 kgs) ,23 Ibs (10.4 kgs) 23.9lbs (10;.85 kgs) „23 lbs (10.4 kgs) . 45 lbs (20.4 kgs) 60 Ibs (27.2 kgs) Liquid Capacity 12.96 gal (49.06L) 21.6 gal (81.8 L) 18.9 gal (71.541) 21.6 gal (81.81) 39.4 gal (149.1 l) 52.0 gal (197 L) Connection size (mechanical) (110 mm available on request) 2" 2" 2" '2"'(3925A02) . ' . 39 , 3 "(3935A03) ,, 4 "(3935A04)- , 3 "(3950A03( . 4 "(3950A04) * Max capacity calculated based on data at PDI G101 test approval. All other mo Canplas Industries Ltd. P.O. Box 1800, 500 Veterans Drive Barrie, Ontario, Canada L4M 4V3 Tel: (705) 726 -3361 Toll Free: 1-800-461-5300 Fax: (705) 726-2186 GD- 000205- EN•02.12 PRINTED IN CANADA /data quote figures ASME 112.14.3 Breakdown. Canplas LLC 11402 East 53rd Ave. Suite 700, Denver, CO, U.SA. 80239 Tel: (303) 373 -1918 Toll Free: 1-888-461-5307 Fax: (303) 373-1923 ru, QAllaXIS mmpnny December 7, 2012 Hardeep Singh 2818 144 Pl SW Lynnwood, WA 98087 • City of Tukwila • Jim Haggerton, Mayor Department of Community Development JackPace, Director RE: Correction Letter #3 Plumbing /Gas Piping Permit Application Number PG12 -195 Express Shop — 458 Southcenter Mall Dear Mr. Singh, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. The Public Works Department has no comments at this time. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, t/c4f0 Bill Rambo Permit Technician encl File: PG12 -195 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: December 6, 2012 Project Name: Express Shop Permit # PG12 -195 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Please provide a complete water piping isometric plan including connections to all fixtures, hot water tanks and appliances such as pop dispensers, coffee machines etc. and show backflow devices if required. Make and model of backflows will be needed. 2. Please provide a detail plan of the hot water tank and installation showing support and seismic securing and also typical requirements like T & P valve and drain, expansion tank shut of valve, drain pan, etc. 3. Please show point of connection to existing water. Should there be questions concerning the above information please contact the Building Division at 206 - 431 -3670. December 3, 2012 Hardeep Singh 2818 144 P1 SW Lynnwood, WA 98087 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Correction Letter #2 Plumbing /Gas Piping Permit Application Number PG12 -195 Express Shop — 458 Southcenter Mall Dear Mr. Singh, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. The Public Works Department has no comments at this time. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, ( PAA/ Je fifer Ma hall Pe t Tec cian en1 File: PG12 -195 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo #2 Date: November 30, 2012 Project Name: Express Shop Permit # PG12 -195 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 1 1 x 17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Please address all 6 items on the first review memo. The arrow pointing to the point of connection to the existing system is not pointing to an existing drain line. Grease interceptor calculations were not provided. The new isometric line drawing does not show the triple sink and the grease interceptor has nothing connected to it in this same isometric. Basically all 6 items were not addressed in your response to my first review memo. Please review each item individually and correct the plans as necessary. The change should be clouded and it is helpful to provide a response letter corresponding to my review memo explaining were changes are located to address each item. Should there be questions concerning the above information please contact the Building Division at 206 - 431 -3670. City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director November 7, 2012 Hardeep Singh 2818 144 PI SW Lynnwood, WA 98087 RE: Correction Letter #1 Plumbing /Gas Piping Permit Application Number PG12 -195 Express Shop — 458 Southcenter Mall Dear Mr. Singh, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. The Public Works Department has no comments at this time. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely Bill Rambo Permit Technician encl File: PGI2 -195 W:\Permit Center \Correction Letters \2012\PG 12 -195 Correction Letter # 1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: November 7, 2012 Project Name: Express Shop Permit # PG12 -195 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Change the scale noted on the plans from 1/8 inch per foot to 'A inch per foot. 2. Provide grease interceptor sizing calculations per the UPC and base calculations on a one minute drain flow. 3. The p -trap for the triple sink needs to come off the center sink. Please show this on the DW and V isometric line drawing. 4. A separate vent is required for the triple sink p -trap and the grease interceptor. The grease interceptor vent is installed just downstream of the flow regulator as shown on the specs provided from the manufacturer. The vents may tie together above the flood rim of the triple sink. Please revise the line drawing as necessary to show this. 5. Please show on the floor plan where the new DW &V will tie into the existing. Add this connection to the line drawing and show the size of the drain pipe that you will be tying into. 6. Will the triple sink be used for food prep or just pot and pan washing? If food prep is proposed, the triple sink will need to be connected to the sanitary drainage via an indirect waste. Should there be questions concerning the above information please contact the Building Division at 206- 431 -3670. CO C • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG12 -195 DATE: 12 -10 -12 PROJECT NAME: EXPRESS SHOP SITE ADDRESS: 458 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 3 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: ill C uilding ii Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -11 -12 Complete Incomplete ❑ Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions DUE DATE: 01 -08-13 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 4PERMIT COORD PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG12 -195 DATE: 12/05/12 PROJECT NAME: EXPRESS SHOP SITE ADDRESS: 458 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 2 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: IL 1-110-0- uilding Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12/06/12 Complete Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route IX Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/03/13 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: ! 1r;)� Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: OPERMIi COORD COP* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG12 -195 DATE: 11/26/12 PROJECT NAME: EXPRESS SHOP SITE ADDRESS: 458 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: uilding Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11/27/12 Complete Incomplete ❑ Not Applicable Comments: Permit Center Use` Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 12/25/12 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments)] Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only , CORRECTION LETTER MAILED: Departments issued corrections: Bldg ►: Fire ❑ Ping ❑ PW ❑ Staff Initials:_jM' • PERMIT CU D COSY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG12 -195 DATE: 11 -05 -12 PROJECT NAME: EXPRESS SHOP SITE ADDRESS: 458 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued • DEPAR MEN S: uilding Division �ublic Wrrlts 1\-- `Lk Fire Prevention n Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -06-12 Complete Incomplete n Not Applicable ❑ Comments: Permit Center Use Only _ INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required nNo further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Notation: REVIEWER'S INITIALS: DUE DATE: 12 -04 -12 Not Approved (attach comments) ,j DATE: Perinit: Center 'Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: VD;) I o Plan Check/Permit Number: PG 12 -195 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 3 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Express Shop Project Address: 458 Southcenter Mall '0 Contact Person: 1 (,> hone Number: LS(2 S > 2 W ?7 Summary of Revision: Q1,'i7N rc fns 1^ l'T ( %2 "TvArt IL pl,oa---, 3 \�c� C_trt 6r4-Q_7c osr-r RECEIVFD CITY OF TUKWILA DEC 10 2012 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including d, rev Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 1 [ \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 17-'042, Plan Check/Permit Number: PG 12 -195 ❑ Response to Incomplete Letter # • Response to Correction Letter # 2 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Express Shop Project Address: 458 Southcenter Mall REC ��nFrtE�ta DEC 0 5 2012 PERMIT CENTER Contact Person: ,14AS2n .-0 shhoi Phone Number: Summary of Revision: I. V <LA) 6'- C 7HE 3- (o /r7f ) 4 wA(2I to frit PL7l 1:4r4O L7 -1-14r<a . Lcr LL a Fays)LS - wg te,,pc P'. O 1 ac'/ )- , r'-41 fop° pi I J( Lot, r, -' , bt, _ u se-Le-In/4 r7/ L/2pvA/3L‘ 'Poop 1117 lnr(-)es I1-t R ny Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: AEntered in Permits Plus on C: \Users \jennifer -m \Desktop \Revision Submittal Form.doc Revised: May 2011 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: PG 12 -195 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 Revision # after Permit is Issued A Aa+ENED ❑ ITy nr ,ALA ❑ Revision requested by a City Building Inspector or Plans Examiner NOV 2 6 2012 Express Shop �tRMll CENTER Project Name: p p ` Project Address: 458 Southcenter Mall Contact Person: l'iP■2(L=Ve ��'�` i Phone Number: -:"1'� � ).--(=g Summary of Revision: Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople Peer Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name PETER HAMMER CONSTRUCTION LLC UBI No. 602991801 Phone 2067691280 Status Active Address 15409 30Th Ave S License No. PETERHC907DK Suite /Apt. License Type Construction Contractor City Seattle Effective Date 3/12/2010 State WA Expiration Date 3/12/2014 Zip 98188 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date RIVAS, PEDRO M Partner /Member 03/12/2010 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 Navigators Ins Co 46BCO24211 03/07/2012 Until Cancelled $12,000.0003/05 /2012 3 American Contractors Indem CO 100156594 03/07/2011 Until Cancelled 05/21/2012 $12,000.00 03/08 /2011 2 American Contractors Indem CO 100116217 03/16/2010 03/07/2011 $12,000.0005/03 /2010 1 American Contractors Indem CO 100116217 03/08/2010 03/16/2010 $6,000.0003/12/2010 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 United Specialty Insurance Com 0S34090 03/07/2011 03/07/2013 $1,000,000.00 03/05/2012 1 UNDERWRITERS AT LLOYDS A1Q917331 03/08/2010 03/08/2011 $500,000.00 03/12/2010 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 12/12/2012 (N) LOCATION REVISE DATA /COMMUNICATIONS (E) PANEL MODIFY EXISTING OUTL ADJUSTABLE SHELVES AS TO GFI. NEEDED. RECONFIGURE EXISTING PANELS FOR NEW EQUIPMENT. BY OTHERS UNDER SEPARATE PERMIT. MAINTAIN MIN. 30" CLEARANCE AT ELEC. EXISTING SHELVING + l' -0 "AFF 36" DOOR INTO COOLER BY COOLER VENDOR EXISTING DATA COMMUNICATIONS PANEL TO BE RELOCATED. COO 5 ODIFY EXISTING CASWORK (N) 3 COMP SINK (N) GREASE INTERCEPTOR (E) (E) .34 *..6�.,�.. 36" EXISTING SHELVING lro + I' -0 "AFF REMOVE EXISTING CPT AND REPLACE WITH VCT -1 UNDER COOLERS RELOCATE EXISTING THERMOSTAT. COORDINATE NEW LOCATION WITH ARCHITECT/TENANT. EXISTING LL DEMISING WALL TO REMAIN 0 ER 0 (N) MOP SINK, PROVIDE H0T ND COLD WATER. EXISTING PATH OF TRAVEL, 87 LF, TO BE MAINTAINED. SEE EXITING SUMMARY, COVER SHEET CS1/0 EXISTING ADA COMPLIANT RESTROOM TO REMAIN. SEE PLUMBING REQUIREMENTS SUMMARY, SHEET CSI.0. EXISTING PORCELAIN TILE TO REMAIN. EXISTING VCT TO REMAIN. SURFACE MOUNTED FLOOR BOXES, TYP. REMOVE EXISTING CPT AND REPLACE WITH VCT -2 T1- IRUOUT SALES FLOOR EXISTING LL DEMISING WALL TO REMAIN SALES 1 3' -0" EU VCT -2 MALL ENTRANCE DEMO /EXITING /PART I T I ON/ELECTRI CAL SCALE: 1 /S" • I' -0" CONTINUE POWER THRU CASEWORK REMOVE EXISTING TILE AND WALK OFF MAT. PROVIDE (N) WALK OFF MAT (N) VCT FLOOR SEE FINISH SCHEDULE, A6.1 EXISTING GLASS STOREFRONT AND ENTRY DOORS TO REMAIN. DUKE ±S CHOWDER HOUSE ADJACENT TENANT ALL EXISTING LIGHTING, MECHANICAL, LIFE SAFETY DEVISES TO REMAIN EXCEPT AS NOTED OR REQUIRED BY CODE. REMOVE EXISTING DOWN LIGHTS RELOCATE EXISTING MECHANICAL D IFFUSER ALIGN NEW SOFFIT WITH COOLER/DOORS BELOW PROVIDE (N) 50 GAL. WATER HEATER ABOVE EXISTING CEILING. SUPPORT PLATFORM TO BE GALVANIZED PAN ATTACHED TO STRUCTURE WITH ALLTHREAD BOLTS AND PIPED TO DRAIN. MEN V \ ■ ■M Gag 1!1 E6 001 lei 7 k A tn • • • • • • 1� 1 V—\1 .. •• V N • • • • 17—NI • • 0 0 0 REFLECTED CEILING FLAN SCALE: I /S" ■ I' -0" s S 111 EXISTING CEILING FAN TO REMAIN. EXISTING EXIT LIGHTING AND HORN /STROBE TO REMAIN. EXISTING VAV DEVICE AND TB TO REMAIN. (N) LOW VOLTAGE PENDANT LIGHT EXISTING EMERGENCY LIGHTING TO REMAIN. EXISTING MECHANICAL SCREENS TO REMAIN. VERIFY EXISTING JBOX TO REUSE FOR TENANT SIGNAGE BY OTHERS UNDER SEPARATE PERMIT. SYMBOLS EQUIPMENT LIST AND NOTES SYMBOLS NEW PARTITION IKON - STRUCTURAL EXISTING PARTITION/ BUILDING SI-ELL DEMO WALL/CASEWORK WALL TYPE KEY NOTE INDICATOR ROOM NAMEMIMBER DOOR NUMBER FEC E] NEW U14LL MOUNTED FIRE EXTINGUISHER CABINEt DETAIL INDICATOR ELEVAtION INDICATOR SECTION INDICATOR }no NEW FLOOR DRAIN OFLOOR BOX SURFACE MOUNTED TRANSPOWER FLOOR MONIED T V EXISTING ELECTRICAL PANEL TO REIMAIN EXISTING DATA/CG4I INICATIONS to BE RELOCATED NEW LOCATION OF ExISTINCs DATA COM•NNICATIONS EXISTING ELECTRICAL TO REMAIN EXISTING DATA/CoMMNICATIONS TO REMAN (N) FLOOR SINK 01 REFRIGERATED FOOD CASES: TURBO AIR "TOM -4015" 0 SLURPEE: BUNN ULTRA -2,1-IP 0 SODA: MD 1564 ® ICE TEA: BUNN TB6a Q CAPPUCINO: CURTIS EXPRIO. O COFFEE BREW: GEMINI 3G K COFFEE WARM: BUNN AZIOSM m/e TWIN ® MICROWAVE: AMANA RCSIOPBDA O g CIGARETTES: CADEMAN KD -1220 POS- BY TENANT 11 BAKERY DISPLAY: FEDERAL CK -I0 12 NOT USED 13 ATM: BY VENDOR 14 SHELVES: BY TENANT 15 WALK IN COOLER: BY OTHERS UNDER SEPARATE PERMIT EXISTING ADJUSTABLE 16 PLASTIC LAMINATE SHELVES TO REMAIN. 0 REFRIGERATED BEVERAGE CASES: BY VENDOR 18 HAND WASH SINK: ADVANCE TABCO DI -I -10 19 PAPER TOWEL DISPENSER: BOBRICK 8 -262 ® SOAP DISPENSER: 818615 21 MOP SINK: GSW- SE2424FM Q GONDOLAS: LOZIER ISLAND Q GREASE INTERCEPTOR ENDURA" ® 3 COMP SINK: EAGLE GROUP 314- 1S -24L WITH DRAIN BOARDS 80T14 SIDES. • 50 GALLON WATER HEATER RHEEM 831(852 -2 ELECTRIC. NO CHANGES WILL BE MADE WITHOUT HEALTH DEPARTMENT APPROVAL PUBLIC HEALTH- SEATTTLE 4 KING COUNTYINSPECTION REQUIRED ON COMPLETION OF WO5RK PRIOR TO OPENING. REVISIONS No changes shall be made to the scope Of work without prior approval of Tukwila Building Division. P<OT" Rsvi siOt"'e3 will raquire a new plan submit* I and may include additional plan review fay;. SEPARATE PERMIT REQUIRED FOR: Cechanicat Electrical ❑ Plumbing Las Piping Silt' of Tukwila DIVISION 1• ■ ■■I ■.,•■ WINN V TB • EXISTING RECESSED WALL WASH EXISTING RECESSED SPOT EXISTING DOIIINLIGNT EXISTING DOIUNLIGNT EXISTING EMERGENCY LIGHT EXISTING FLUORESCENT (DIAGONAL INDICATES EMER'iENGY LIGHT ON SO MINUTE BATTERY BACK UP) EXISTING EXIT LIGHT EXISTING WORN STROBE EXISTING MECHANICAL DEVICE EXISTING MECHANICAL DEVICE EXISTING CEILING FAN EXISTING RETURN EXISTING SUPPLY EXISTING FIRE SPRINKLERS RECEIVED CITY OF TUKWILA NOV 0 5 2012 PERMIT CENTER desi 94 UNION SNTREET SEATTLE WnkSHINOTO�101 (OT FZLE COPY Permri Pt' c °°i \I approval is subject to error and omisslont � ccn ru Tian documents does rat &uph: ; t3 ol. arty adopted code or ordinance. Ric pt o iJprOved FiGi4 Copy and conditions/is acilmowledgwd. By_ CL.t \D„\\IIA\-1, City Of Tukwila BUILDING DIVISION rp•-i 0 1-4 1-4 ?)1 g 88 (/) 4.4 ccn r.T.4 Pk' o rT1 06537 REGISTERED ARCHITECT RODNEY A. BAUCH STATE OF WASHINGTON REVIEWED FOR CODE COMPLIANCE APPROVED DEC 11 2012 11L v1/2— City of Tukwila BUILDING DIVISION 'PG a•m. I Revision Date Description 10/9/2012 PERMIT SET 11/1/2012 HEALTH DEPARTMENT REVISIONS Scale 1/8" = I' -0" Job Number I2- 325.01 Date 10/8/2012 Drawn. RBA Checked RBA DEMO /PART /ELEC REFL CLNG PLAN A1.1 / _ _a 0 (N) MOP SINK, PROVIDE H0T ND COLD WATER. EXISTING PATH OF TRAVEL, 87 LF, TO BE MAINTAINED. SEE EXITING SUMMARY, COVER SHEET CS1/0 EXISTING ADA COMPLIANT RESTROOM TO REMAIN. SEE PLUMBING REQUIREMENTS SUMMARY, SHEET CSI.0. EXISTING PORCELAIN TILE TO REMAIN. EXISTING VCT TO REMAIN. SURFACE MOUNTED FLOOR BOXES, TYP. REMOVE EXISTING CPT AND REPLACE WITH VCT -2 T1- IRUOUT SALES FLOOR EXISTING LL DEMISING WALL TO REMAIN SALES 1 3' -0" EU VCT -2 MALL ENTRANCE DEMO /EXITING /PART I T I ON/ELECTRI CAL SCALE: 1 /S" • I' -0" CONTINUE POWER THRU CASEWORK REMOVE EXISTING TILE AND WALK OFF MAT. PROVIDE (N) WALK OFF MAT (N) VCT FLOOR SEE FINISH SCHEDULE, A6.1 EXISTING GLASS STOREFRONT AND ENTRY DOORS TO REMAIN. DUKE ±S CHOWDER HOUSE ADJACENT TENANT ALL EXISTING LIGHTING, MECHANICAL, LIFE SAFETY DEVISES TO REMAIN EXCEPT AS NOTED OR REQUIRED BY CODE. REMOVE EXISTING DOWN LIGHTS RELOCATE EXISTING MECHANICAL D IFFUSER ALIGN NEW SOFFIT WITH COOLER/DOORS BELOW PROVIDE (N) 50 GAL. WATER HEATER ABOVE EXISTING CEILING. SUPPORT PLATFORM TO BE GALVANIZED PAN ATTACHED TO STRUCTURE WITH ALLTHREAD BOLTS AND PIPED TO DRAIN. MEN V \ ■ ■M Gag 1!1 E6 001 lei 7 k A tn • • • • • • 1� 1 V—\1 .. •• V N • • • • 17—NI • • 0 0 0 REFLECTED CEILING FLAN SCALE: I /S" ■ I' -0" s S 111 EXISTING CEILING FAN TO REMAIN. EXISTING EXIT LIGHTING AND HORN /STROBE TO REMAIN. EXISTING VAV DEVICE AND TB TO REMAIN. (N) LOW VOLTAGE PENDANT LIGHT EXISTING EMERGENCY LIGHTING TO REMAIN. EXISTING MECHANICAL SCREENS TO REMAIN. VERIFY EXISTING JBOX TO REUSE FOR TENANT SIGNAGE BY OTHERS UNDER SEPARATE PERMIT. SYMBOLS EQUIPMENT LIST AND NOTES SYMBOLS NEW PARTITION IKON - STRUCTURAL EXISTING PARTITION/ BUILDING SI-ELL DEMO WALL/CASEWORK WALL TYPE KEY NOTE INDICATOR ROOM NAMEMIMBER DOOR NUMBER FEC E] NEW U14LL MOUNTED FIRE EXTINGUISHER CABINEt DETAIL INDICATOR ELEVAtION INDICATOR SECTION INDICATOR }no NEW FLOOR DRAIN OFLOOR BOX SURFACE MOUNTED TRANSPOWER FLOOR MONIED T V EXISTING ELECTRICAL PANEL TO REIMAIN EXISTING DATA/CG4I INICATIONS to BE RELOCATED NEW LOCATION OF ExISTINCs DATA COM•NNICATIONS EXISTING ELECTRICAL TO REMAIN EXISTING DATA/CoMMNICATIONS TO REMAN (N) FLOOR SINK 01 REFRIGERATED FOOD CASES: TURBO AIR "TOM -4015" 0 SLURPEE: BUNN ULTRA -2,1-IP 0 SODA: MD 1564 ® ICE TEA: BUNN TB6a Q CAPPUCINO: CURTIS EXPRIO. O COFFEE BREW: GEMINI 3G K COFFEE WARM: BUNN AZIOSM m/e TWIN ® MICROWAVE: AMANA RCSIOPBDA O g CIGARETTES: CADEMAN KD -1220 POS- BY TENANT 11 BAKERY DISPLAY: FEDERAL CK -I0 12 NOT USED 13 ATM: BY VENDOR 14 SHELVES: BY TENANT 15 WALK IN COOLER: BY OTHERS UNDER SEPARATE PERMIT EXISTING ADJUSTABLE 16 PLASTIC LAMINATE SHELVES TO REMAIN. 0 REFRIGERATED BEVERAGE CASES: BY VENDOR 18 HAND WASH SINK: ADVANCE TABCO DI -I -10 19 PAPER TOWEL DISPENSER: BOBRICK 8 -262 ® SOAP DISPENSER: 818615 21 MOP SINK: GSW- SE2424FM Q GONDOLAS: LOZIER ISLAND Q GREASE INTERCEPTOR ENDURA" ® 3 COMP SINK: EAGLE GROUP 314- 1S -24L WITH DRAIN BOARDS 80T14 SIDES. • 50 GALLON WATER HEATER RHEEM 831(852 -2 ELECTRIC. NO CHANGES WILL BE MADE WITHOUT HEALTH DEPARTMENT APPROVAL PUBLIC HEALTH- SEATTTLE 4 KING COUNTYINSPECTION REQUIRED ON COMPLETION OF WO5RK PRIOR TO OPENING. REVISIONS No changes shall be made to the scope Of work without prior approval of Tukwila Building Division. P<OT" Rsvi siOt"'e3 will raquire a new plan submit* I and may include additional plan review fay;. SEPARATE PERMIT REQUIRED FOR: Cechanicat Electrical ❑ Plumbing Las Piping Silt' of Tukwila DIVISION 1• ■ ■■I ■.,•■ WINN V TB • EXISTING RECESSED WALL WASH EXISTING RECESSED SPOT EXISTING DOIIINLIGNT EXISTING DOIUNLIGNT EXISTING EMERGENCY LIGHT EXISTING FLUORESCENT (DIAGONAL INDICATES EMER'iENGY LIGHT ON SO MINUTE BATTERY BACK UP) EXISTING EXIT LIGHT EXISTING WORN STROBE EXISTING MECHANICAL DEVICE EXISTING MECHANICAL DEVICE EXISTING CEILING FAN EXISTING RETURN EXISTING SUPPLY EXISTING FIRE SPRINKLERS RECEIVED CITY OF TUKWILA NOV 0 5 2012 PERMIT CENTER desi 94 UNION SNTREET SEATTLE WnkSHINOTO�101 (OT FZLE COPY Permri Pt' c °°i \I approval is subject to error and omisslont � ccn ru Tian documents does rat &uph: ; t3 ol. arty adopted code or ordinance. Ric pt o iJprOved FiGi4 Copy and conditions/is acilmowledgwd. By_ CL.t \D„\\IIA\-1, City Of Tukwila BUILDING DIVISION rp•-i 0 1-4 1-4 ?)1 g 88 (/) 4.4 ccn r.T.4 Pk' o rT1 06537 REGISTERED ARCHITECT RODNEY A. BAUCH STATE OF WASHINGTON REVIEWED FOR CODE COMPLIANCE APPROVED DEC 11 2012 11L v1/2— City of Tukwila BUILDING DIVISION 'PG a•m. I Revision Date Description 10/9/2012 PERMIT SET 11/1/2012 HEALTH DEPARTMENT REVISIONS Scale 1/8" = I' -0" Job Number I2- 325.01 Date 10/8/2012 Drawn. RBA Checked RBA DEMO /PART /ELEC REFL CLNG PLAN A1.1 EXPRESS SHOP (N) LOCATION DATA /COMMUNICATIONS PANEL MODIFY EXISTING ADJUSTABLE SHELVES A NEEDED. RECONFIGURE EXISTING PANELS FOR NEW EQUIP I,EN' -13Y"DTI -IERS UNDER SEPARATE.. PERMIT.' --.. MAINTAIN MIN. 30 CLEARANCE AT ELEC. NO FOOD PREP REVISE MODIFY EXI5 (E) GASWOW OUTL 5 TO GFI. r._ EXISTING SHELVING 1t -IDt, • •.• 8.1 ; y, 1• (N) HAND SINK NEW 3 "LINE POC EXSISTING3" CO EXSISTING DRAIN -(N)3 C (N) G INTE NOW I �® _TILE 31„011 3 A EXISTING DATA COMMUNICATIONS PANEL TO BE RELOCATED. EXISTING SHELVING 11 -0"AFF .41 -2184 • r :3:" OTE: MECHANICAL AND ELECTRICAL FOR GOOLE BY OTHERS UNDER 5EF'ARATE PERMIT. ALIGN SOFFIT ABOVE COOLERS WITH FRONT FACE OF COOLER- SEE 2 /All AND 2/A6.1 REMOVE EXISTING CPT AND REPLACE WITH VCT -1 UNDER COOLERS mei • ; I ; AL. 001 0 3' 0 /1.1111.1■11 RELOCATE EXISTING THERMOSTAT, COORDINATE NEW LOCATION WITH ARCHITECT/TENANT. EXISTING LL DEMISING WALL TO REMAIN r O m 0 00 0 z • MALL ENTRANCE f 0 cm� O m 8. DEMO /EXITING/PARTITION/ELECTRICAL SCALE: 1/4- 1' -On • • -! • _ 1: ►, 12 1, • O 0 r-- • 4 • • • 21st 0 1'e.O A (N) MOP SINK; PROVIDE HOT ND COLD WATER TING PAT , S-I L 0 = AINTAINED. SEE EXITING SUMMARY, COVER SHEET C$1/0 • EXISTING ADA COMPLIANT STROOM TO REMAIN. -SEE PLUMBING REQUIREMENTS •SUMMARY, SHEET CS1.0. • EXISTING PORCELAIN TILE TO REMAIN. EXISTING VCT TO ACE MOUNTED FLO XES, TYPE REMOVE EXISTING CPT AND REPLACE WITH VCT -2 TI-IRUOUT SALES FLOOR EXISTING LL DEMISING WALL TO REMAIN • DEMOLISH EXISTING DRESSING ROOM PLATFORM AND STALLS. DEMOLISH EXISTING CASEWORK FROM PREVIOUS TENANT. CONTINUE POWER THRU CASEWORK . REMOVE EX ING TILE AND WALK OFF MAT. PROVIDE (N) WALK OFF MAT (N) VCT FLOOR SEE FINISH SCHEDULE, A ›.1 .-- EXISTING CAL A 55 STOREFRONT AND ENTRY DOORS TO REMAIN. ,FKE ;S CHOWDER HOUSE ADJACENT TENANT ra r1111131.11..0 heft ettosnw•1ulfan 0— r+uTars Q arm scam J Iwo ROIR IVJGEOREneGS918tc1DrET fJ7 OL7M.11lti pl maw Nocuous letiLIXIMUN wcareattl FACIV lam 1RUeKRINROPl :WM © 1 1 1 9 CanNSGLET ats,sums. 101OIW trall0 DAIA feJZ&TD rC1 LorASIDI Of OWNS DMA COtONCATIDIS DWG =MCA TO WSW v moo aaltonorntassomot 0J oUµOpIMK \• • Iof A1R1 IR 11 FOOD GLSES 71.11.7'O 1.4cc • Oi ROME, EOM LL ^A•tP p SODA•FAO 364 ® YE TEa oats limo • CORM 5FAO ‘!"441 U E Mt MN ADM %1 O MKWOIt1AVE. ATIt,NA IL'stttroDA ® C ASETTES , GADEMAN ICD•R10 • Pc sr TE,w r ® nacERT D1•.t:AT. FEDERAL OCAO ® NOT IMO U AIM AY YVCOR s+sr RAtI ti ROGS DG TOGSTSG ADAATADLE ®PIASTIGLa 1ATEb .vr.s TO MAR. O !AVERAGE CAKE. OT VERZR ® wro L' A51L strc. ADVANCE TAaXO _.... Pl.I- • PAPERTO SEI VAPORER OMRY.K E462 6OAP DINrFNSER 8565 Tt t1OP5MGGEO GE24 E, EAR 6 CAME. CR T3CIRA •1M•• GOrb4?Y. a K0GRAr wea P WARM eonl GOES revLL.OG GAM NEATER,-/ R38TS OS1RSfx CN 9 WILL . 0 GSA STUOAFD GALL L t1 MT wio *MOW NO -LEAD !A110ET.• NS•1660 1 DE WITHOUT I4EALTN AL PUBLIC 1EALTN•6EATITLE 4 IC.NG CCINfl N5PECTIGN REfi I D ON COMPL£TIOW OF WOW PRIOR TO OPENItY. EE Y 2" .� 2" EXSISTING VENT FROM BATHROOM BELOW 12" N 2" 2 1 1 2" 1 CO MOP SINK N. 11/2" 1 %% )2'1C0 1 �`�\ 11/2" I FD J 11/2" �• r l G.I 3COMP CO IN1 , 4" EXSISTING 'BUILDING DRAIN FD 2 FD11 ■ ...... .. ..., .... I DRAIN WASTE & VENT REVIEWED FOR CODE COMPLIANCE APPROVED DEC 112012 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 102012 PERMIT CENTER EXPRESS SHOP SCALE.: N . S DATE: 12/5/2012 APPROVED BY: DRAWN BY GSM REVISED GSM DRAWING NUMBER 2 3/41__ . MOP SINK./ 3 COMP SINK/ (r) 3/4' T &P 1" PAN DRAIN i (indirect to mop sink) with air gap L PROVIDE BACKING FOR ANCHORING 1/2" 1/2" ICE HAND SINK EXPANSION TANK IC OFFEE /ESPRESSO RPBA WATTS #009 Note:Based on no data on equiptment, feild verify • 1/2" ins Product Features Wall mount water heater platform Wide platform accommodates water heaters up to 50- Gallons Platform also serves as a drain pan 1- Inchmetat drain fitting Assembly required RECEIVED CITY OF TUKWILA. DEC 10 2012 PERMIT CENTER SCALE: N : S APPROVED wY: DRAWN RY GSM REVISED GSM DRAWING HUMBER 2 •.`.--ii.'.; s' :.;Ei';i1; ! ;-::. • ..::: . K . ' :, .:; `-:. SUBMITTAL SHEET Part Description: : 1 35GPM GREASE INTERCEPTOR Pad Number 3935A04 Camila* Induatrha Ltd Canis las LLC 500 Veterans Drive 11402 East 53rd Ave. Bard% Orgaris. 1400-4614300 Denver. CO 1-008-461-5307 s . I • . . •• • ''":;:'. ... 5"---.' f.. '' ..:'::' ' 1 . .. D ... 1 t .1. •' . 1 1- -- .. . s"f ' O rt. s I . : ..' . :: : . . : '.. • ;. : 7"‘'.' ', : ' . ": - .. %• 7- 410 e ••1 Put 0 Pan UPC 5110 Vachon an CV 3235404 W2121330122 4 1 Olownelens (1nchw) A B C 0 E 2e.500 23.500 5.000 12.503 12.500 Gin Oar Code CM WI ittpl 10010471390124 24 320 Cln WI Inn) 53015 8814 Cubic 1.108 04) Stld Coble 01) Ct1%si5114 Cer1011 Clifton Cube Cubs (141 Pi 69.119 0 021214268844 T.52 GREASE INTERCEPTOR FORMULA BOWL SIZE: 20X16X10.5X3 10:003 C.I VOLUME IN GALLONS 10,080/231=43.7 75%Capacity 0.75X43.7= 32.8 GAL. ONE MINUTE DRAIN DOWN 32.8 GPM FLOW RATE 1 Profit from the Eagle Advantage 412 Series Sinks CD Sinks with One Compartment 0 412 Series Sinks model # 412.16.1 41246-148R or L 41246-148 412464-24R or L 412-16.1.24 412-244 412-24-148R or L 412.24-1-18 412.24.1.24R or L 412-24-1-24 Item No Project No.: S.I.S. No.: T 41 CO INC TOP VIEW OF ONE•COMPARTMENT SINKS bowl dimensions dr ainboar d over al I dimensions width length length width In. mm in. mm quantity In. mm In. mm 406 0 27W 899 406 1 18" 457 27W 699 406 2 18" 457 27'.1" 699 406 1 24" 610 271/5" 699 406 2 24" 610 2714" 699 610 • 0 31:4" 807 610 1 18" 457 31,4" 807 610 2 18 457 3114- 807 610 1 24 610 3114" 807 610 2 24" 610 3134 807 20" 508 20" 508 20" 508 20' 508 20" 508 16" 1r 16" 16 24" 610 24" 24" 610 24 24- 610 24" 24" 610 24" 24" 610 24" Sinks with Two Compartments model # 412.16.2 41246-248R or L 412-16-248 41246-2-24R or L 412-16-2-24 412.24.2 412-24-2-18R or 1. 412-24-2-18 4/2-24-2-24R or 1. 412-24.2.24 w 1 DID bowl dimensions width length in. mm in. mm 20" 20" 20" 20* 20" 508 508 508 508 508 16' 406 16 406 16 406 18 406 16 406 24" 24" 24" 24" 24" 610 610 610 610 610 24" 24" 24 24 24" Sinks with Three Compartments model # 41246-3 41246-348R or L 41246448 412-16-3-24R or L 41246-3-24 412.24.3 • 412-24-348R or L. • 412-24-348 • 412-24-3-24R or 1. 412-24-3•24 • 610 610 610 610 610 T 1 -1 I CM Boa length In. nun 23X" 591 38W 987 544" 1384 444_ 1140 66W 1689 31W 800 46W 1188 62 1575 5211" 1340 74' 1880 L weight lbs. kg 40 18.1 59 26.8 78 35.4 65 29.5 90 40.8 60 27.2 79 35.8 98 44.5 85 38.6 110 49.9 TOP VIEW OF TWO-COMPATITMENT SINKS dr ainboar d over all dimensions length • width • length quantity in. mm In. mm In. mm 0 27'4 899 41" 1041 1 18 457 2flV 699 56W 1438 2 18 457 271 699 72!4 1835 1 24" 610 27W • 699 62W 1591 2 24" 610 274" 699 WA" 2140 0 • 314 807 57I4 1461 1 18" 457 314 807 72W 1847 2 18 457 3134" 807 88 2235 1 24" 610 3134" 807 78W 2000 2 24" 610 314 807 100" 2540 I-L-I bowl dimensions width length in. mm in. mm 20" 20" 20 20 20 508 16 508 16" 508 lr SOB 16" 508 16- 406 406 406 406 406 w weight lbs. kg 64 29.0 83 37.6 102 46.3 89 40.4 114 51.7 90 40.8 109 49.4 128 58.1 115 52.2 140 63.5 11311:11311 TOP VIEW OF THREE-COMPARTMENT SINKS dr alnboard quantity 0 1 2 1 2 length in. mm 18' 457 18 457 24" 610 24" 610 ov*ralI dimensions width length In. mm in. mm 27W 699 58W 27X" 699 74W 27W 699 90- 271.5" 699 803i" 27W 699 102' 1492 1895 2286 2042 2591 weight lbs. ha 85 38.6 104 47.2 123 55.8 110 49.9 135 61.2 24" 24" 24" 24" 24" 610 24" 610 24" 610 24" 610 24" 610 24" 610 610 610 810 610 0 1 18 457 2 18- 457 1 24" 610 2 24 610 • Features two sets of faucet holes. EAGLE GROUP 100 Industrial Boulevard, Clayton, DE 19938-8903 USA Phone: 302-653-3000 • Fax: 302-653-2065 www.eaglegrp.com Foodservice Division: Phone 800-441-8440 MRC/Retall Display Divisions: Phone 800-637-5100 31A 313A" 3134" 31W 301-• 807 807 807 807 807 83W 2121 mor 2508 114' 2896 toor 2661 126' 3200 125 144 163 150 175 56.7 65.3 73.9 68.0 79.4 T 1 Printed in U.S.A. 02012 by Eagle Group Rev. 06/12 Spec sheds available for viewing prinlmn or downloading from our onhne ideratare Vilna y at www edulegrp.catil Although every attempt has been made to ensure the accuracy of the information provided. we cannot be held responsible for typographical or printing errors. Information and specifications are subject to change without notice. Please confirm at time of order. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1 1 2012 City of Tukwila BUILDING DIVISION EXPRESS SHOP RECEIVED CITY OF TUKWILA DEC 10 2012 PERMIT CENTER SCALE: N s APPROVED SY: owsz:i 12/5/2012 DRAWING NUMBER 2