HomeMy WebLinkAboutPermit PG12-202 - SOMA INTIMATESSOMA INTIMATES
260 SOUThCENTER MALL
PG1 2-202
City *Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206- 431 -2451
Web site: htto: / /www.TukwilaWA.gov
PLUMBING /GAS PIPING PERMIT
Parcel No.: 9202470010
Address: 260 SOVTHCENTER MALL TUKW
Project Name: SOMA INTIMATES
Permit Number: PG12 -202
Issue Date: 02/04/2013
Permit Expires On: 08/03/2013
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA 92013
Contact Person:
Name: MARY RYAN
Address: PO BOX 3749 , MISSION VIEJO CA 92690
Email: MARY @PERMTTRESOURCES.COM
Contractor:
Name: RUSSELL- FILAND BUILDERS INC
Address: 15396 N 83 AV, STE F100 , PEORIA AZ 85381
Contractor License No: RUSSEBI958N9
Phone: 949 582 -3735
Phone: 623 412 -8999
Expiration Date: 09/25/2014
DESCRIPTION OF WORK:
RESTROOM WORK
Value of Plumbing /Gas Piping: $5,000.00 Uniform Plumbing Code Edition: 2009
Fees Collected: $206.06 International Fuel Gas Code Edition: 2009
Electrical Service Provided by:
Permit Center Authorized Signature: (AA- Date: 04 D413
I hereby certify that I have read an ex fined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be compli d wit , whether specified herein or not.
The granting of this permit does not pr s e to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions
on the back of this permit.
Signature:
Print Name:
ift
L L 10-4/ loop
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -4/10
PG 12 -202 Printed: 02 -04 -2013
PERMIT CONDITIONS
Permit No. PG 12 -202
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures
and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use
significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in
accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments.
13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
doc: UPC -4/10
PG12 -202 Printed: 02 -04 -2013
•
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: / /www.Tukwi laW A.gov
Plumbing/Gas Permit No.
Project No
Date Application Accepted:
Date Application Expires: O , (, 2
(For office use only)
L
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION ,
Site Address:
Tenant Name:
SD U� King Co Assessor's Tax
/� i'/ Suite Numb-
PROPERTY OWNER
�r
Name: Weep/ 1 b 6 C �N 6,,
v � �
CJ��
Address: // / ovz,
,
City C 4,L 6/s State/1 Zip94
CONTACT PERSON= person receiving all project'
communication
Name: �%,A'�y ,q-4/ 04 j/ f 1
Address: .0% g 3
City: /i.s+s',o / V / , % D S t a t e : Z ip: ‘776
-61 oy P5 _76Phone:
Email: f2 y /e-,ri Ai-aatec C
New Tenant:
❑ Yes ❑..No
PLUMBING CONTRACTOR INFORMATION
CompanyName dot
5 /`C- &✓f . _T M
Address/ 20 J.
Uv4,0e_ _J /6 ,
City,V .ez /l
Stateeht— 7 Zip:: _.gO 8
Phone: / /9. ,
jJ—D
Contr Reg No.: /i L 0 5
Exp Date:
1ukwila Business License No.:
1-36
Valuation of Project (contractor's bid price): $�`�'� p-� U-/-1
Scope of Work (please provide deed information): N LA4 ■rz "
64/4,✓4- 5O, lz D �-- o ,v� �/ e 644/
//V 19-4/ X S � •u� - C.,/a4- e-E4/
(K,E-110(1-1- (fru 12-x=
Building Use (per Int'I Building Code).
Occupancy (per Intl Building Code):
Utility Purveyor:
H:\Applications \Forms - Applications On Line\201 I Applications\Plumbing Permit Application Revised 8 -9.1 l.docx
Revised: August 2011
bh
Sewer
Page 1 of 2
•
S
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type . .
' Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Drinking fountain or water
cooler (per head)
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Urinal
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
I
Each additional medical
gas inlets/outlets greater
than 5
I
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Repair or alteration of
water piping and /or water
treatment equipment
Fixture Type
Qty
Bidet
Food -waste grinder,
commercial
Drinking fountain or water
cooler (per head)
Wash fountain
Lavatory
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Urinal
Repair or alter of
drainage or vent piping
I
Water yheater and /or vent
I
Gas piping outlets
Repair or alteration of
water piping and /or water
treatment equipment
I
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
PERMIT APPLICATION NOTES -
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
I
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alter of
drainage or vent piping
I
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
I
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1 -5
inlets /outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN R AUTHORIZED -' NT:
Signature:
Print Name:
Mailing Address:
Date: // 72
Day Telephone: 36-
37 /f, •SS,Qit. �� � — a� 96
ci state Zip
H:\Applications\Forms- Applications On Line\201 I Applications\ Plumbing Permit Application Revised 8- 9- 11.docx
Revised: August 2011
bh
Page 2 of 2
Ciik of Tukwila,
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: //www. ci. tukwila.wa. us
SET RECEIPT
Copy Reprinted on 02 -04 -2013 at 08:05:51 02/04/2013
RECEIPT NO: RI3 -00697
Initials: JEM
Payment Date: 02/04/2013
User ID: 1165 Total Payment: 2,538.32
Payee: DENNIS M FILAND (BY PHONE)
SET ID: 0204 SET NAME: Temporary Set
SET TRANSACTIONS:
Set Member Amount
D12 -367 1,930.15
EL12 -1088 443.32
PG12 -202 164.85
TOTAL: 1,930.15
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA 2,538.32
TOTAL: 2,538.32
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
ELECTRICAL PERMIT - NONR
ELECTRICAL PLAN - NONRES
PLUMBING - NONRES
STATE BUILDING SURCHARGE
000.322.100
000.322.101.00.0
000.345.832.00.0
000.322.103.00.0
640.237.114
TOTAL:
1,925.65
436.50
6.82
164.85
4.50
2,538.32
City of 1 wilar
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: htm: /bvww.ct.nukwila.wa. us
SET RECEIPT
Copy Reprinted on 11 -19 -2012 at 09:43:58 11/19/2012
RECEIPT NO: R12 -03149
Initials: JEM
User ID: 1165
Payee: PERMIT RESOURCES, INC.
Payment Date: 11/19/2012
Total Payment: 1,461.30
SET ID: S000001828 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member Amount
D12 -367 1,251.67
EL12 -1088 102.31
M12 -180 66.11
PG12 -202 41.21
TOTAL: 1,251.67
TRANSACTION LIST:
Type Method Description Amount
Payment Check 21601 1,461.30
TOTAL: 1,461.30
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PLAN - NONRES 000.345.832.00.0
PLAN CHECK - NONRES 000.345.830
TOTAL:
102.31
1,358.99
1,461.30
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Proj er -
Type of Inspection:
c---`-' ,0J -\ P(<J r B
��- v tai -� l�'(> ,
Addrzsza 0 5c m44(
Date Called:
Special Instructions:
Date Wanted: -� -
? ---1-7
13
m.
.�_
Requester:
Phoie No: .-755
&S
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
D efurr c -o» p(
()
it
Date:' ' t 3
n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Pro ct:
a Ak.,4 ..� -, ;`r LtA�' J
Type of Inspection: f�
G r O J Ao W o r
Address:
Z..t� s c...- ,4 C I
Date ailed:
-
tC-a 3 Cok
Special Instructions: '
Date Wanted:
`t —13
<,,ra-
p.m.
Requester:
Phone S 3 — Z j..a --i
Approved per applicable codes.
Corrections required prior to approval. 'O
COMMENTS:
(
fr.
6 A ■
4-0 01-'/-,_5J Dia(
;
I � t
r
/0'
1-4-12A4
ot‘
J
V
Inspe� or:
n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
*ERMII C00% VOP
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG12 -202 DATE: 11/19/12
PROJECT NAME: SOMA INTIMATES
SITE ADDRESS: 260 SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
tt rL
uilding Division
`per \\\N 11.2.2.11
Public Works
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete NI
Incomplete ❑
DUE DATE: 11/20/12
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route tg Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 12/18/12
Approved ❑ Approved with Conditions N
Notation:
REVIEWER'S INITIALS:
Not Approved (attach comments) ❑
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Contractors or Tradespeople Printer Friendly Page Page 1 of 2
S
General /Specialty Contractor
A business registered as a construction contractor with Lai to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name RUSSELL - FILAND BUILDERS INC UBI No. 602233054
Phone 6234128999 Status Active
Address 15396 N 83Rd Ave Suite F -100 License No. RUSSEBI958N9
Suite /Apt. License Type Construction Contractor
City Peoria Effective Date 8/29/2005
State AZ Expiration Date 9/25/2014
Zip 85381 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
CRANECW98605
CRANE
CONSTRUCTION WEST
INC
Construction
Contractor
General
Unused
9/25/2002
9/25/2004
Archived
CRANECCO23J1
CRANE
CONSTRUCTION
COMPANY LLC
Construction
Contractor
General
Unused
4/21/1998
12/23/2011
Expired
RUSSEBI962JG
RUSSELL CRANE
BUILDERS INC
Construction
Contractor
General
Unused
4/7/2004
9/25/2006
Inactive
Business Owner Information
Name
Role
Effective Date
Expiration Date
CORPORATION SERVICE CO
Agent
08/29/2005
Amount
FILAND, DENNIS MICHAEL
President
10/03/2011
2092205039
RICH, TIFFANY NICOLE
Secretary
08/27/2012
BROWN, MICHAEL ALLAN
Director
10/03/2011
08/27/2012
CRANE, JEFFREY DAVID
Director
10/03/2011
08/27/2012
GRANDE, RALPH ANTHONY
Secretary
08/29/2005
08/27/2012
PODGORNY, MICHAEL ANTHONY
Vice President
10/03/2011
08/27/2012
CRANE, JEFFREY D
President
08/29/2005
10/03/2011
CRANE, JEFFREY D
Treasurer
08/29/2005
10/03/2011
BROWN, MICHAEL A
Vice President
08/29/2005
10/03/2011
Bond Information
bib
V '
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
3
GREAT AMERICAN INS
CO
1753605
04/05/2006
Until Cancelled
$12,000.00
03/17/2006
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
6
Valley Co l Forge Ins
2092205039
12/01/2009
12/01/2013
$1,000,000.00
12/03/2012
5
VALLEY FORGE
INS CO
2084946931
12/01/2006
12/01/2010
$1,000,000.00
12/01/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
02/04/2013
FILE COPY
Permit No. CAt\I---
P! , review approval is subject to errors and omissions.
Approval of construction documents does not auth - :7s
thla. v oiation of any adopted code or ordinance. Rec pt
of c.pproved Field Copy and F ; '' I' • is acknowledgd:
By aM
Date :,
city Of Tukwila
BUILDING DIVISION
UNLESS OT1- IERWISE SPECIFIED, CONTRACTOR SHALL PROVIDE ALL NECESSARY EQUIPMENT,
MATERIAL, LABOR AND SUPERVISION NECESSARY TO COMPLETE THE PLUMBING WORK IN
ACCORDANCE WITH THE SPECIFICATIONS AND STANDARDS,
2. FIELD VERIFY EXACT SIZE AND LOCATION OF EXISTING WASTE PIPING BELOW SLAB, VENT PIPING
ABOVE CEILING AND COLD WATER SUPPLY PIPING ABOVE CEILING PRIOR TO COMMENCEMENT OF ANY
WORK. AFTER INSTALLATION AND FINAL CONNECTION OF NEW WASTE PIPING BELOW SLAB, BACK FILL
AND PATCH IN ACCORDANCE WITH THE LANDLORD'S CRITERIA REGARDING SUCH WORK.
3. CONTRACTOR SHALL INSTALL ALL PLUMBING FIXTURES AS PROVIDED BY CHICO'S FAS NATIONAL
ACCOUNT REPRESENTATIVE, AND S1 -4ALL FURNISH AND INSTALL ALL REQUIRED VALVES, PIPING,
HANGERS, ETC. REQUIRED FOR A COMPLETE PLUMBING SYSTEM TO SERVE THE DEMISED PREMISES
FROM SANITARY AND COLD WATER CONNECTIONS PROVIDED BY LANDLORD. ALL FIXTURES, VALVES,
PIPING AND APPURTENANCES REQUIRED FOR A FULL ROUGH -IN SHALL BE FURNISHED AND
INSTALLED BY CONTRACTOR.
SEAL AROUND ALL PIPES PENETRATING FIRE SEPARATIONS WITH LISTED AND APPROVED FIRE SEAL
MATERIAL. ONLY LISTED AND APPROVED SEALANTS AND METHODS FOR THE SPECIFIC USE WILL BE
PERMITTED.
5. SANITARY VENT SI -(ALL BE ROUTED TO EXISTING LANDLORD VENT.
6. CONTRACTOR SHALL ENSURE THAT ALL SLAB OR FLOOR PENETRATIONS WITHIN THE DEMISED
PREMISES ARE PROPERLY SEALED AND REMAIN WATERTIGHT TO PREVENT ANY POSSIBLE DAMAGE
TO TI-1E BUILDING AND /OR SURROUNDING AREAS. FAILURE TO DO SO SHALL BE AT THE RISK AND
SOLE EXPENSE OF THE CONTRACTOR.
ALL MATERIAL SHALL BE NEW AND OF COMMERCIAL GRADE, AND BEAR UNDERWRITER'S
LABORATORIES AND UNION LABELS WHERE SUCH LABELING APPLIES.
8. CONTRACTOR TO FIELD VERIFY SLOPE AND ELEVATION OF EXISTING SANITARY PRIOR TO ANY NEW
PLUMBING INSTALLATION.
q. CONTRACTOR MUST VISIT THE JOBSITE TO BECOME FAMILIAR WITH MAJOR ITEMS SUCH AS
STRUCTURAL ELEMENTS AND OTHER EXISTING JOB CONDITIONS THAT MAY AFFECT THE WORK.
ADDITIONALLY, CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS
WASTE, VENTS, WATER LINES, ETC.
10 CONTRACTOR SHALL FOLLOW ALL SPECIFICATIONS AND DETAILS CONTAINED IN DESIGN CRITERIA OF
TENANT HANDBOOK AND OTHER LANDLORD REQUIREMENTS.
II. CONTRACTOR TO CLEAR ALL EXISTING AND NEW DRAIN LINES AND FIXTURES, PRIOR TO TURNING
OVER SPACE TO TENANT.
12: CONTRACTOR SHALL PROVIDE ACCESS TO ALL NEW AND EXISTING ITEMS REQUIRING ACCESS
(VALVES, TRAP PRIMERS, ETC.) INSTALLED BEHIND WALLS, FLOORS OR CEILINGS. CONTRACTOR
SHALL ALSO VERIFY THAT ALL SUCH ITEMS ARE OPERABLE AND FULLY ACCESSIBLE TI- IROUGI -I
ACCESS PROVIDED.
13. ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE.
14. ANY EXISTING WALL /FLOOR OR CEILING SURFACE THAT IS DAMAGED BY THIS CONTRACTOR DURING
CONSTRUCTION SHALL BE REPAIRED TO MATCH' NEW AND /OR EXISTING CONDITIONS AT THIS
CONTRACTOR'S EXPENSE.
15. CONTRACTOR SHALL DEMOLISH AND COMPLETELY REMOVE ALL PLUMBING FIXTURES EQUIPMENT,
PIPING, ETC. NOT BEING REUSED OR SERVING ANOTHER SPACE. CAP ALL PIPES BEHIND FINISHED
SURFACES (WALLS, FLOORS, ETC.) AND PATCH SURFACES TO MATCH SURROUNDING AREA.
16. FIELD VERIFY ALL CONDITIONS PRIOR TO BID. REFER TO RESPONSIBILITY SCHEDULE ON SHEET G1.2
FOR MORE INFORMATION.
17. GENERAL CONTRACTOR TO INSURE THAT STUDS ARE NOT TO BE CUT OR MODIFIED FOR PLUMBING
AND ELECTRICAL RUNS.
I. EXTEND NEW SANITARY WASTE LINE TO EXISTING SANITARY WASTE AND CONNECT. PROVIDE FLOOR
CLEANOUT AT CONNECTION. FIELD VERIFY AND COORDINATE EXACT LOCATION, SIZE, INVERT
ELEVATION, DIRECTION OF FLOW AND ALL OTHER REQUIREMENTS OF EXISTING SANITARY WASTE LINE
PRIOR TO BID. PATCH SLAB TO MATCH SURROUNDING AREA. NEW SANITARY LINE SHALL BE
PRESSURE TESTED PER LOCAL CODES WIT1 -I A MINIMUM REQUIREMENT OF 'HOLDING 10 FT. W.C. FOR
TWO HOURS. REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION.
2. EXTEND NEW VENT LINE TO EXISTING PLUMBING VENT, FIELD VERIFY AND COORDINATE EXACT SIZE,
ELEVATION, LOCATION AND ALL OTHER REQUIREMENTS PRIOR TO BID.
3. EXTEND NEW 3/4" COLD WATER LINE TO LANDLORD PROVIDED TAP AND CONNECT. PROVIDE
SHUT -OFF VALVE AND REDUCED PRESSURE BACKFLOW PREVENTER. FIELD VERIFY EXACT LOCATION,
ELEVATION, SIZE AND ALL OTHER REQUIREMENTS OF NEW TAP PRIOR TO BID. REFER TO RISER
DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION.
4. NH -1: INSTALL NEW INSTANTANEOUS WATER 1- (EATER ON WALL FOR LAVATORY. SEE RISER DIAGRAM,
PLUMBING FIXTURE SCHEDULE AND DETAIL K ON TI-115 SHEET FOR REQUIREMENTS.
5. ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE.
REFER TO PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION.
6. INSTALL I/2" WATER PIPE FROM TRAP PRIMER DOWN IN WALL UNDER FLOOR TO FLOOR DRAIN. TRAP
PRIMER TO BE LOCATED IN AN ACCESSIBLE LOCATION.
7. FURNISH AND INSTALL WATER HAMMER ARRESTER IN THE DOMESTIC COLD WATER PIPING AS SHOWN
ON TI-4E WATER RISER DIAGRAM. WATER HAMMER ARRESTER TO BE LOCATED IN AN ACCESSIBLE
LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE
ACCEPTABLE.
8. ROUTE HORIZONTAL PIPING ABOVE PLATFORM, DROP WATER SERVICE TO FIXTURE. AVOID
INTERFERENCE WITH PLATFORM AS REQUIRED.
PLUMBING GENERAL NOTES
PLUMBING CODED NOTES
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV a 0 201!
itYNT
OWNER:
chico's
11215 METRO PARKWAY
FT. MYERS, FL. 33966
D
FINISHED FLOOR
FLON CONTROL
MIXING VALVE
WATER HEATER
JUNCTION BOX
1/2" CW
IN WALL
WATER HEATER DETAIL
SEPARATE E PERMIT
REQUIRED FOR:
14 Mechanical
El Electrical
❑ Plumbing
ig Gas Piping
City of Tukwila
BUILDING DIVISION
N.T.S.
CH-
1-11N -
SAN
COND
- - -V - --
- - - (E)XX-
DT H• iri•-.H>T4 BACK
DOMESTIC WATER PIPE
DOMESTIC HOT WATER
GAS PIPE
SANITARY PIPE
CONDENSATE PIPE
SANITARY VENT PIPE
EXISTING PIPE OR EQUIPMENT
o--2 PIPE - UP
C -. PIPE - DOWN
›TG,
101
C-2
AB.
AFF.
ARCH.
BEL.
BLDG.
CLG.
CO
COND
CONT.
CW
ACCESS DOOR
FLOW PREV.
COMBINATION BALANCE / SHUT -OFF
GATE VALVE
GLOBE VALVE
DRAIN VALVE
CHECK VALVE
UNION
GAGE COCK
CHECK VALVE
BUTTERFLY VALVE
BALANCE VALVE
OR GAS VALVE
BALL VALVE
Y -TYPE STRAINER
GAPPED LINE
CONNECT TO EXISTING
WATER METER
ABOVE
ABOVE FINISHED FLOOR
ARCHITECT
BELOW
BUILDING
CEILING
CLEAN OUT
CONDENSATE PIPE
CONTI NUAT ION
GOLD WATER
CONTR. CONTRACTOR
COORD. COORDINATE
DISC. DISCONNECT
DN. DOWN
EA. EACH
EX. EXISTING
ENG ELECTRIC WATER
COOLER
FCO FLOOR CLEAN OUT
FD FLOOR DRAIN
FIXT. FIXTURE
FPC. FIRE PROTECTION
CONTRACTOR
FIRE PROTECTION
PIPE
FURN. FURNISH
FV. FLUSH VALVE
G GAS
GAL. GALLON
GC. GENERAL
CONTRACTOR
GPH. GALLONS PER
HOUR
GPM. GALLONS PER
MINUTE
HB HOSE BIBB
HC. HEATING
CONTRACTOR
HP. HORSEPOWER
HN HOT NAT ER
LAV . LAVATORY
MAX. MAXIMUM
MFR. MANUFACTURER
MT. MOUNT
NTS. NOT TO SCALE
PG. PLUMBING
CONTRACTOR
PLBG. PLUMBING
R RELOCATE
RD ROOF DRAIN
SAN SANITARY
If TRAP PRIMER
TYP. TYPICAL
UR URINAL
V VENT
VTR VENT THROUGH
ROOF
WC WATER CLOSET
NCO WALL CLEAN OUT
WI-1 WATER HEATER
W/ WITH
FP
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
PLUMBING FIXTURE
-- -> -. • •• VIIQ
SCHEDUL BUILDING DIVISION
GENERAL CONTRACTOR SHALL INSTALL THE FOLLOWING FIXTURES AS FURNISHED BY CHICO'S FAS NATIONAL ACCOUNTS
REPRESENTATIVE. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL ALL ACCESSORIES REQUIRED TO ROUGH -IN FIXTURES.
MARK
FIXTURE
MANUFACTURER AND
MODEL NO.
CW
HW
WASTE
TRAP
REMARKS
WC-1
WATER
CLOSET
AMERICAN STANDARD
#2386.012
(SEE RESPONSIBILITY
SCHEDULE ON GI .2)
1/2"
-
4"
-
ADA COMPLIANT, VITRROUS CHINA, ELONGATED
SIPHON ACTION, 1.6 GPF, HANDLE ON OPPOSITE
SIDE FROM WALL, AMERICAN STANDARD SEAT
#5325.024. GC TO PROVIDE: 3/8" C.P. SUPPLY WITH
HANDLE STOP AND 18" MTG. HT. TO BOWL.
El-1
WATER
COOLER
ASIS NO. P8ACSL
I/2"
-
1 -1/2"
I -I/2"
WHEELCHAIR ACCESSIBLE . e -- • • RNI5H
W A. _•- - - •TE. GC TO PROVIDE CHROME
-- RAP SUPPLY STOP. MOUNT TO "ANSI"
STANDARD - " MAX. FROM FLOOR TO
SPOUT OUTLET.
(SEE
RESPONSIBILITY
- =- - • • G1.2)
MS-
:- - • -
(GREY)
ZURN (GREY)
#Z1g9 .- '- o _
(SEE RESPONSIBILITY
SCHED !" . -
1/2"
1/2"
3"
1 -1/2"
24 "x24 "x10 ", GREY MOLDED - = '
CO - • ,I:- - • ITH MUSTEE HOSE, BRACKET
#65.700 AND MOP HANGER #65,600. AMERICAN STD.
F • P . • ■ GRAL VACUUM BREAKER
#8344.012.004 (ROUGH C - • -
-
GC SHALL INSTALL THE FOLLOWING NON- STANDARD FIXTURES FURNISHED BY CHICO'S FAS NATIONAL ACCOUNTS
REPRESENTATIVE. GC SHALL FURNISH AND INSTALL ALL ACCESSORIES REQUIRED TO ROUGH -IN FIXTURES.
LAV -I
LAVATORY
AMERICAN STANDARD.
#0124.024
STANDARD LAV -1
1/2"
1/2"
1 -1/2"
1 -1/2"
WALL MOUNTED 18.5 "x20" VITREOUS CHINA, 4 -INCH
CENTERS, WHITE COLOR WITH AMERICAN STANDARD
FAUCET #6059.205 (HARDWIRED "SELECTRONIC"
PROXIMITY FAUCET) AND MCGU IRE SUPPLY STOP
#155AECO. GC TO PROVIDE: JOSAM 17105 -67 SERIES
CARRIER, AND MOUNT SINK AT WHEELCHAIR HEIGHT.
WITH NON - STANDARD
FAUCET
(SEE RESPONSIBILITY
SCHEDULE ON G1.2)
WI-1-1
WATER
HEATER
(INSTANTANEOUS)
CHRONOMITE
INSTA -FLOW #SR -20L
NON- STANDARD I.
WATER 'HEATER
(SEE RESPONSIBILITY
SCHEDULE ON GI.2)
1/2"
1/2"
-
-
MODEL SR -20L, 0.5 GPM @ 57° RISE, 4.2 KW, 20A
AT 208V- 1P1-4 -60NZ. GC TO PROVIDE ADJUSTABLE
THERMOSTATIC MIXING VALVE SET AT 110 °F.
GC SHALL FURNISH AND INSTALL THE FOLLOWING FIXTURES COMPLETE WITH ALL ACCESSORIES REQUIRED FOR ROUGH -IN.
MARK
FIXTURE
MANUFACTURER AND
MODEL NO.
CW
HW
WASTE
TRAP
REMARKS
FD -1
FLOOR
DRAIN
ZURN
#Z -415
1/2"
-
3"
1/2"
3" PIPE SIZE 1A1/TYPE "B" POLISHED NICKEL BRONZE
STRAINER. (PROVIDE 1N/TRAP PRIMER IF REQUIRED
BY CODE OR SHOWN ON DRAWINGS)
WI-IA
WATER
HAMMER
ARRESTER
SIOUX CHIEF #750
SERIES.
3/4"
3/4"
-
-
OR EQUAL BY PRECISION PLUMBING PRODUCTS, INC.
TP
TRAP
PRIMER
PRECISION #P2 -500
1/2"
-
-
-
FLOW ACTIVATED BRONZE TRAP SEAL PRIMER WITH
INTEGRAL VACUUM BREAKER, 1/2" SWEAT INLET
AND OUTLET CONNECTIONS, AND 1/2" IPS DRIP LINE
CONNECTION.
NCO
WALL CLEAN
OUT
ZURN #ZANB- 1460 -q
-
-
4"
-
CAST IRON CLEAN OUT TEE WITH BRONZE
THREADED CLEAN OUT PLUG. PLUG TO BE GAS
AND WATER TIGHT. WALL ACCESS PANEL -
9 "x°1" WALL PANEL AND FRAME; SMOOTH NICKEL
BRONZE PANEL SET FLUSH TO FINISHED WALL
PLANE. FURNISHED WITH SECURING LUGS.
FCC'
FLOOR
CLEAN OUT
ZURN 11Z- 1400 -1-1D -2
-
-
-
-
(CONG. FLOOR) OR ZN- 1400 -2 (TILE FLOOR). CAST
IRON BODY WITH GAS AND WATER TIGHT ABS
TAPERED THREAD PLUG AND ROUND SCORIATED
TOP ADJUSTABLE TO FINISH FLOOR.
ADDITIONAL ACCESSORIES PROVIDED BY CHICO S FAS NATIONAL ACCOUNT REPRESENTATIVE AND INSTALLED BY
GENERAL CONTRACTOR: MOP HANGER BRACKET.
PLUMBING FIXTURE SCHEDULE, SYMBOLS & ABB
REVIATIONS
NH -1
I- 1/2 :„.
2' I
I 2"
4"
4"
4:Iv FCO
1 -1/2"
II
WC -1
I -1/2"
NCO
JcE:1l
LAV -1
1/2" FROM TP
ARCHITECT / ENGINEER:
U
0
x
W
info@shremshock.com
U
0
0
w
E
v3�
0
C
0
CD do )
Lo
N
C N Lo
C • at,
W
U �I°
O.a=n
_C c
E
0
c0
THE ENGINEER ASSUMES NO RESPONSIBILITY OR
LIABILITY FOR THE USE OF THESE PLANS FOR ANY
PROJECT OTHER THAN SPECIFICALLY AUTHORIZED
BY THEM AND SIGNED AND SEALED FOR SUCH
SPECIFIC LOCATION IN THE STATE SHOWN ON THE
SEAL. THIS BUILDING USE IS ONLY APPLICABLE IN
AREAS MEETING THE STATED DESIGN CRITERIA.
Jorna
INTIMATES
STORE NO:
5381
PROJECT LOCATION:
WESTFIELD
SOUTHCENTER MALL
2800 SOUTHCENTER MALL
SPACE NO.: 116
TU KW I LA, WA 98188
DESIGN TYPE:
LINEN & LACE
REVISIONS:
REQUIRED BY: DATE
" INDICATES NO REVISION TO THIS SHEET
DRAWN BY: WRG
CHECKED BY: JTP
CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED
SEISMIC AND STRUCTURAL SUPPORTS FOR ALL PLUMBING
FIXTURES, EQUIPMENT, PIPING, ETC. PROVIDE LATERAL
SUPPORT AS REQUIRED PER IBC 200q SEISMIC DESIGN
CATEGORY D. FIELD VERIFY AND COORDINATE ALL
REQUIREMENTS WITH AUTHORITY HAVING JURISDICTION.
LAVATORY
ADJACENT TENANT
NON -SALES
WATER RISER
N.T.S.
SANITARY STACK
N.T.S.
li
NORTH
lt.
n e
•• H 1--CW 3/4"
RECEIVED ,.
CITY OF TUKIMLA
NOV 1.6 2012
PERMIT CENTER
E PARTIAL PLUMBING PLAN
1/4" = 11 -0"
DRAWING TITLE:
PLUMBING
SCHEDULES
AND DETAILS
DATE ISSUED:
11/07/2012
PROJECT NO:
120421
DRAWING NO:
M3.0