City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
NOTICE OF DECISION
TO: Rick Cardoza, Applicant
Verizon Wireless, Owner
May 6, 2009
This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project
and permit approval.
I. PROJECT INFORMATION
Project File Number: L09 -016
Applicant: Rick Cardoza for Verizon Wireless
Type of Permit Applied for: Type 1 Wireless Telecommunications Facilities Permit
Project Description: Modification of an existing antenna, which includes relocating two
existing sectors to the top of tower, replacing panel antenna, and
replacing coax. The height of the existing monopole is 121'. Some of
the antennas were attached at 121' and others at 71'. This proposal is to
relocate the antennas at 71' to 121' and add some new antennas at 121'.
Location: 13130 44`h Avenue South
Associated Files: N/A
Comprehensive Plan Commercial/Light Industrial (C/LI)
Designation/Zoning
District:
II. DECISION
SEPA Determination: The City SEPA Responsible Official has previously determined that this application
does not require a SEPA threshold determination because it is categorically exempt.
Decision on Substantive Permit: The City Community Development Director has determined that the
application for a Type 1 Wireless Telecommunications Facility does comply with applicable City and state
code requirements and has approved that application, subject to any conditions which are set forth in the
Decision.
CT Page 1 of 3
P: \Users \Courtney \L Files \2009_05_06_NOD.doc
05/06/2009
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax: 206 -431 -3665
• •
III. YOUR APPEAL RIGHTS
The Decision on this Permit Application is a Type 1 decision pursuant to Tukwila Municipal Code
§ 18.104.010. Other land use applications related to this project may still be pending.
No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the City Hearing
Examiner of the Decision on the Permit itself is permitted. If an MDNS was issued, any person wishing to
challenge either the conditions which were imposed by the MDNS decision or the failure of the Department
to impose additional conditions in the MDNS must raise such issues as part of the appeal to the Hearing
Examiner.
A party who is not satisfied with the outcome of the Hearing Examiner appeal process may file an appeal in
King County Superior Court from the Hearing Examiner's decision.
IV. PROCEDURES AND TIME FOR APPEALING
In order to appeal the Community Development Director decision on the Permit Application, a written
notice of appeal must be filed with the Department of Community Development within 14 days of the
issuance of this Decision, that is by May 20, 2009.
The requirements for such appeals are set forth in Tukwila Municipal Code ch. 18.116. All appeal
materials shall be submitted to the Department of Community Development. Appeal materials MUST
include:
1. The name of the appealing party.
2. The address and phone number of the appealing party; and if the appealing party is a corporation,
association or other group, the address and phone number of a contact person authorized to receive
notices on the appealing party's behalf.
3. A statement identifying the decision being appealed and the alleged errors in the decision, including
any specific challenge to an MDNS.
4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in
the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief
sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal.
5. Appeal fee of $225.
V. APPEAL HEARINGS PROCESS
Any administrative appeal regarding the Permit shall be conducted as a closed record hearing before the
Hearing Examiner based on the information presented to the Community Development Director, who
made the original decision. No new evidence or testimony will be permitted during the appeal hearing.
Parties will be allowed to present oral argument based on the information presented to the Community
Development Director before their decision was issued. The Hearing Examiner's decision on the appeal is
the City's final decision.
Any party wishing to challenge the Hearing Examiner's decision on this application must file an appeal
pursuant to the procedures and time limitations set forth in RCW ch. 36.70C. An appeal challenging a
CT Page 2 of 3 05/06/2009
P: \Users \Courtney \L Files \2009_05_06_NOD.doc
• •
DNS, an MDNS or an EIS may be included in such an appeal. If no appeal of the Hearing Examiner's
decision is properly filed in Superior Court within such time limit, the Decision on this permit will be
final. The City's decision to issue a DNS, an MDNS or an EIS is final for this permit and any other
pending permit applications for the development of the subject property.
VI. INSPECTION OF INFORMATION ON THE APPLICATION
Project materials including the application, any staff reports, and other studies related to the permits are
available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd.,
Suite 100, Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The
project planner is Courtney Thomson, who may be contacted at 206 - 431 -2164 or via email at
cthomson @ci.tukwila.wa.us for further information.
Property owners affected by this decision may request a change in valuation for their property tax purposes.
Contact the King County Assessor's Office for further information regarding property tax valuation changes.
441,(;,,4J2_ Lt-(4-4
Department of Community Development
City of Tukwila
CT Page 3 of 3 05/06/2009
P: \Users \Courtney \L Files \2009_05_06_NOD.doc
• •
STAFF REPORT TO THE DIRECTOR
PREPARED May 6, 2009
NOTIFICATION: Notification is not required for a Type I land use application.
FILE NUMBER: L09 -016
APPLICANT: Rick Cardoza
OWNER: Verizon Wireless
REQUEST: Approval of a Type I Wireless Telecommunication Facilities
Permit in order to relocate two existing antenna sectors to the top of
tower, replace panel antenna, and replace coax.
LOCATION: 13130 44`h Ave. S.
ASSOCIATED
PERMITS: N/A
SEPA
DETERMINATION: Exempt
COMPREHENSIVE PLAN
DESIGNATION: Commercial/Light Industrial (C/LI)
ZONE DESIGNATION: Commercial/Light Industrial (C/LI)
STAFF: Courtney Thomson, Planning Intern
ATTACHMENTS: Project Plans for permit L09 -016
CT Page 1 of 6 05/06/2009
P: \Users \Courtney\. Files \2009_05_06_WCF_StaffReport.doc
• •
FINDINGS
Vicinity /Site Information
Project Description
The applicant is requesting approval of a Type I Wireless Telecommunication Facilities [WCF] Permit to
modify an existing antenna at 13130 44`h Avenue South. The project includes relocating two existing
sectors to the top of tower, replacing panel antenna, and replacing coax. The height of the existing
monopole is 121'. Some of the antennas were attached at 121' while some were at 71'. This proposal is
to relocate the antennas at 71' to 121' and add some new antennas at 121'.
Existing Development
Aside from the tower, the only existing structures on the parcel are two equipment shelters.
Surrounding Land Uses
The property and all adjacent parcels are zoned C/LI. The site is bordered to the south by South 133rd
Street and to the west by Highway 599.
BACKGROUND
In 2006, the City adopted a Wireless Facilities Chapter (TMC 18.71) to the Zoning Code. The chapter
provides specific location and design requirements for the placement of WCF within the City of Tukwila.
The WCF being modified was originally approved by the City in 2000 (L2000 -050) through a conditional
use permit.
Location Selection
Tukwila Municipal Code (TMC) provides a hierarchy of appropriate locations within the City. Generally,
co- locations and utilizing existing structures are favored over the development of new standalone WCF
within the City.
TABLE A
Type of Permit Required, Based on
Type of Wireless Communication Facility
ZONING (1)
TYPE OF FACILITY
RESIDENTIAL
COMMERCIAL
INDUSTRIAL
Transmission Tower
co- location
Type 1
Type 1
Type 1
Adding antennas to an
existing tower
Type 1(2)
Type 1(2)
Type 1(2)
Utility pole co- location
Type 2
Type 2
Type 2
CT
P: \Users \Courtney \L Files \2009_05_06_WCF_StaffReport.doc
Page 2 of 6
05/06/2009
Concealed building
attached
Type 2(3)
Type 2(3)
Type 2(3)
Non - concealed building
attached
Type 2
Type 2
Type 1
New tower or waiver
request
Type 4
Type 4
Type 4
(1)
(2)
(3)
Zoning for any private /public property or right -of -way
Residential — LDR, MDR, or HDR
Commercial — O, MUO, RCC, NCC, RC, RCM, TUC, C /LI or TVS
Industrial - LI, HI, MIC /L, or MIC /H
Provided the height of the tower does not increase and the square footage of the enclosure
area does not increase.
An applicant may request to install a non - concealed building attached facility, under TMC
Section 18.58.150.
The applicant is modifying an existing transmission tower co- location antenna. This decision does not
require the use of any new facilities for placement of the new antennas.
Design Standards
The City provides specific design standards for the placement of WCF within the City of Tukwila. The
table below indicates if the applicant's proposal complies with required standards.
Table 1
pecific Design
Project
Project does
Not Applicable
Notes:
Standards
does comply
not comply
The applicant has not proposed a
generator.
1. Generators must
comply with TMC
8.22 regarding noise.
2.Business License
Requirement
Verizon has a
business license
with the City.
3. Only safety
signage must be
placed on the WCF
The applicant does not propose
any signage.
4. Accommodations
for parking for
maintenance
personal must be
provided.
Parking is not affected by this
modification.
CT
P: \Users \Courtney \L Files \2009_05_06_WCF_StaffReport.doc
Page 3 of 6
05/06/2009
5. Towers shall
either maintain a
galvanized steel
finish or be painted a
neutral color so as to
reduce its visual
obtrusiveness.
Existing tower
will maintain its
galvanized steel
finish.
6. The design of all
buildings and
ancillary structures
shall use materials,
colors, textures,
screening, and
landscaping that will
blend the tower
facilities to the
natural setting and
built environment.
No new buildings or structures
are proposed.
7. Antennas shall
have the same color
scheme as the
structure they are
located on.
Replaced
antennas will
match existing
materials.
8. WCF poles and
towers shall only
have safety lights if
required by a
government agency.
No lighting is proposed.
9. No advertising is
permitted on WCF
No advertising is proposed.
10. Each service
provider shall be
limited to an
equipment enclosure
of 360 square feet.
No new equipment enclosures are
proposed.
11. In residential
zones, the height of
the replaced utility
pole is limited to 10
above the replaced
pole and no taller
than 50.
The existing facility being
modified is not within a
residential zone and the proposal
is not for a utility pole relocation.
12. The replaced
utility pole must be
used by the owner of
the utility pole to
support their utility
lines.
This is not a utility pole facility.
CT Page 4 of 6
P: \Users \Courtney \L Files \2009_05_06_WCF_StaffReport.doc
05/06/2009
13. The replaced
utility pole must
have the color and
general appearance
of the adjacent utility
pole.
This is not a utility pole facility.
14. Coaxial cables
greater than one -half
inch in diameter
must be within the
utility pole.
Coaxial cables
will be routed
inside pole.
15. The proposal
shall not result in a
significant change in
the pedestrian
environment or
preclude the City
from making
pedestrian
improvements.
The proposed modifications will
not affect pedestrian facilities.
16. All cabinet
equipment must be
placed outside of the
City ROW, unless an
exception is granted.
The cabinet equipment is not
mounted in the public ROW.
17. The WCF shall
meet setbacks for the
zone in which it is
locate, unless an
exception is granted.
The WCF meets
setbacks for the
C /LI zone.
18. When adding
antennas to
existing WCF
towers, height
must not exceed
what was
approved under
the original
application to
construct the
tower.
The height
remains the
same as that
approved
previously.
19. Antennas shall
be painted to
match the color
scheme of tower.
Antennas and
tower are
galvanized
steel.
20. Feed lines and
coaxial cables
shall be located
within the tower.
Coaxial cables
will be routed
inside tower.
CT
P: \Users \Courtney \L Files \2009_05_06_WCF_StaffReport.doc
Page 5 of 6
05/06/2009
Those exposed
shall be painted to
match tower.
21. A new cabinet
No new cabinet is proposed.
shall be located
within the
equipment
enclosure that was
approved as part
of the original
application.
CONCLUSIONS
1. The proposed modifications to the existing antenna will not significantly alter the conditions that
currently exist. The height of the antenna and the number of antennas will not change.
2. All coaxial cables and feed lines will be routed inside the tower.
3. As demonstrated in Table 1 the project meets all applicable development standards.
4. The proposed modifications will not alter the surrounding land uses in terms of traffic and
pedestrian circulation, building or site design.
5. No noise will be generated from the new antennas being installed.
6. The wireless communications facility has been designed in a way to minimize any visual impact
from the project.
7. The proposed project is in keeping with the goals and policies of the Comprehensive Land Use
Policy Plan.
RECOMMENDATIONS
The recommendation to the Director of Community Development is to approve this application for a
Type I Wireless Telecommunication Facility permit as applied for by Verizon Wireless with no
conditions.
CT Page 6 of 6 05/06/2009
P: \Users \Courtney \L Files \2009_05_06_WCF_StaffReport.doc
VICINITY MAP
I. 9__e
s,zu1 s;. �411
•
}171,
>3 r •
ttt� 1; I
;I 1
q= 42s1e.,
s1-
t,i
ITEI LOCATION -•
.V-;lR - -1 15 i30m,sL • I -
1
91 1 ( \ ,_.r
11 n 11 j_ I — -meat �,;
133N 31 —L- 57331037 i1 s'GL
• ., i 'r 16 •,t y 9
■ � 'S' 13511 S1 -P!.— / I 4 `n V.:.
N - ,'
r r F I 11 rp-
1 A.S-1371h.51 -. 1' m_1 i '
4�116t
11(_±-7.1 1 r C
C„�, S°laeksr— s-
pit
s-fsBa`ak.
y4,
1. •
∎ IS:]39111:9 -.
'!0;,,, ,t 1 ilr
DRIVING DIRECTIONS
FROM VZW OFFICE:
HEAD EAST ON SE EASTGATE WAY TOWARD 160TH AVE SE, SLIGHT RIGHT ONTO THE 1 -90 RAMP TO SEATTLE. KEEP
LEFT AT THE FORK TO CONTINUE TOWARD 1 -90 W, KEEP LEFT AT THE FORK TO CONTINUE TOWARD 1 -90 W AND
MERGE ONTO 1 -90 W, TAKE THE EXIT ONTO 1.405 S TOWARD RENTON/TACOMA, TAKE THE EXIT TOWARD
SOUTHCENTER BLVD. KEEP RIGHT AT THE FORK TO CONTINUE TOWARD SOUTHCENTER BLVD, KEEP RIGHT AT THE
FORK TO CONTINUE TOWARD SOUTHCENTER BLVD, SHARP RIGHT AT SOUTHCENTER BLVD, TURN LEFT AT 53RD
AVE S /MACADAM RD S, TURN LEFT AT S 144TH ST, TURN RIGHT AT MACADAM RD 5, TURN RIGHT AT $ 131ST PL.
TURN LEFT AT 44TH AVE S, DESTINATION WILL BE ON THE RIGHT.
APPROVAL / SIGN OFF
APPROVED BY:
DATE
SIGNATURE
SITE ACQUISITION
G -1
GENERAL NOTES
•
ZONING
COMPOUND PLAN
A -2
R.F
A -3
ANTENNA PLAN AND DETAILS
CONSTRUCTION MANAGER
ANTENNA DETAILS
QO
PROJECT MANAGER
ISSUE FOR
CONSTRUCTION
JRF
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH
REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED
verjQ1 wireless
SEA RIVERTON
13130 44TH AVE S
SEATTLE, WA 98168
KING COUNTY
ATC SITE #83050
PROJECT INFORMATION
APPLICANT / LESSEE:
VERIZON WIRELESS
3350 161st AVENUE SOUTH
BELLEVUE, WA 98008
PROJECT ENGINEER:
CORNERSTONE ENGINEERING, INC.
16928 WOODINVILLE - REDMOND RD N.E, SUITE 210
WOODINVILLE, WA 98072
MARK W OLSON, P.E.
PH: (425) 487 -1732
FAX: (425) 487 -1734
CODE INFORMATION:
ZONING CLASSIFICATION:
BUILDING CODE:
CODE INFORMATION:
CONSTRUCTION TYPE:
OCCUPANCY:
JURISDICTION:
PROPOSED BUILDING USE:
COMMERCIAL
2006 IBC
ElA/I-IA-222-F 2005 NEC
TELECOMMUNICATIONS
U
CITY OF TUKWILA
UNMANNED TELECOMM.
SITE LOCATION: (BASED ON NAD 83)
LATITUDE:
LONGITUDE:
TOP OF STRUCTURE:
BASE OF STRUCTURE:
PROJECT AREA:
N/A NEW IMPERVIOUS AREA:
0 SQ FT
47° 29'10.3"N
122° 16' 42.4" W
120' -0"
144' -0" AMSL (0' -0" REF)
PROPERTY OWNER:
AIRTOUCH CELLULAR DBA VERIZON WIRELESS
MS 231
15900 SE EASTGATE WY
BELLEVUE, WA 98008
TOWER OWNER:
AMERICAN TOWER CORP.
10 PRESIDENTIAL WAY
WOBURN, MA01801
PH: (781) 926 -4663
FAX: (781) 926 -4555
PROJECT MANAGER:
CONTACT: RICK CARDOZA
PH: (253) 218 -9017
ODELIA PACIFIC CORP.
425 PONTIUS AVE N SUITE 200
SEATTLE, WA 98109
PROJECT CONSULTANT:
CONTACT: GLENN PRIEST
PH: (253) 251 -4563
ODELIA PACIFIC CORP.
425 PONTIUS AVE N SUITE 200
SEATTLE, WA 98109
PARCEL NUMBER(S):
7349200345
AREA OF PARCEL:
9,810 SQ FT
0.23 ACRES
GENERAL INFORMATION:
1. PARKING REQUIREMENTS ARE UNCHANGED.
2. TRAFFIC IS UNAFFECTED.
3. NO SIGNAGE IS PROPOSED.
4. NO ADDITIONAL IMPERVIOUS AREA IS PROPOSED.
PROJECT DESCRIPTION:
THIS PROPOSAL IS FOR THE MODIFICATION OF AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY, CONSISTING OF
THE REMOVAL OF (11) PANEL ANTENNAS, MOVING EXISTING ALPHA & BETA SECTOR T -ARMS AT THE 71 -FOOT LEVEL TO THE
117 -FOOT LEVEL AND REPLACING WITH (12) NEW PANEL ANTENNAS (4 PER SECTOR) AND (4) 1 5/8 "0 COAX TO PROPOSED
ANTENNAS ON AN EXISTING 120 -FOOT HIGH STEEL MONOPOLE.
DRAWING INDEX
DWG.
NO.
DESCRIPTION
T -1
TITLE SHEET
G -1
GENERAL NOTES
A -1
COMPOUND PLAN
A -2
EXISTING & PROPOSED SOUTH ELEVATIONS
A -3
ANTENNA PLAN AND DETAILS
A-4
ANTENNA DETAILS
QO
04 -14 -09
ISSUE FOR
CONSTRUCTION
JRF
MWO
QA
04 -03 -09
ISSUE FOR
CLIENT REVIEW
LJS
MWO
LEGAL DESCRIPTION
RIVERTON REPLAT LOTS 1 TO 5 LOTS 11 & 12 LY SWLY OF THE FOLG DESC LINE - BAAP
OPPOSITE HWY ENGR STA 44 +30 ON THE FA LINE SURVEY OF PRIMARY STATE HWY NO 1
SR 99 FOSTER INTERCHANGE TO S 118TH ST & 435 FT SWLY THEREON TH S 26 -20 -00 E 280
FT M/L TAP 30 FT NWLY WHEN MEAS RADIALLY FROM THE RELOC S 133RD ST C/L OF SAID
HWY PLAN & THE END OF SD LN - TC017 -1600
RECEIVED
UTILITY COMPANY'S
APR 16 zUU9
COMMUNITY
POWER
SEATTLE CITY LIGHT
206 -684 -3000
@L.NT
TELEPHONE
O W EST
425 - 251 -9191
veri�on wireless
We neoor stop woridng for you.
3350 1619 AVE SE / MS 8221
BELLEVUE. WA 98008
10 PACIFIC CORPORATION
PLANS PREPARED BY-
CMMONICHRIN NE
16928 WOODINVILLE- REDMOND RD NE.
SUITE 210
WOODINVILLE. WA 08072
PHONE: (425) 487 -1732 FAX: (425) 487.1734
EMAIL: cei@acornerstone- engr.com
PROJECT INFO
SEA RIVERTON
13130 44TH AVE S
SEATTLE, WA 98168
KING COUNTY
ISSUED FOR.
CCONSTRUCTION
_ REV:: DATE: = DESCRIPTION.= BY:_— CK :_
r DRAWN BY:
CURRENT ISSUE DATE
- LICENSURE
LJS
CHK.: =APV •
I JRF MWO
04 -14 -09
[..-DRAWING INFORMATION'
DRAWING TITLE'
DRAWING NUMBER'
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
TITLE SHEET
T -1
0
CEI JOB NUMBER: 09 -20022
QO
04 -14 -09
ISSUE FOR
CONSTRUCTION
JRF
MWO
QA
04 -03 -09
ISSUE FOR
CLIENT REVIEW
LJS
MWO
r DRAWN BY:
CURRENT ISSUE DATE
- LICENSURE
LJS
CHK.: =APV •
I JRF MWO
04 -14 -09
[..-DRAWING INFORMATION'
DRAWING TITLE'
DRAWING NUMBER'
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
TITLE SHEET
T -1
0
CEI JOB NUMBER: 09 -20022
GENERAL NOTES:
CONCI.E NOTES:
STRUCTURAL NOTES:
1. THE PROPOSED INSTALLATION WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER
• OR SEWER SERVICE.
2. THE PROPOSED INSTALLATION IS UNMANNED AND IS NOT FOR HUMAN HABITATION. (NO
HANDICAP ACCESS IS REQUIRED).
3. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES
PER MONTH, BY VERIZON WIRELESS TECHNICIANS.
4. NO NOISE, SMOKE. DUST OR ODOR WILL RESULT FROM THIS PROPOSAL.
5. OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT PROPOSED.
6. ALL REFERENCES TO SPECIFIC STANDARDS FOR THIS PROPOSAL ARE UNDERSTOOD TO BE THE
LATEST VERSION.
7. THE TENDERED MUST UNDERGO A SITE VISIT TO CAREFULLY EXAMINE AND UNDERSTAND THE
SCOPE OF THE WORK REQUIRED BEFORE BID SUBMISSION. NO COMPENSATION IN ANY FORM
WILL BE PAID FOR EXPENSES RESULTING FROM FAILURE TO DO SO.
8. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS,'THE
CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE
CONSTRUCTION MANAGER.
9. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF CABLE
TRAYS, ELECTRICAL LINES, AND ANTENNA CABLES.
10. ROUTING OF ALL CONDUITS, CABLES, CABLE TRAYS, ETC. IS INDICATED AS PROPOSED
LOCATIONS ONLY. CONFIRM THE EXACT ROUTING WITH THE ON -SITE CONSTRUCTION MANAGER
PRIOR TO THE START OF WORK.
11 ALL DAMAGE OR OPENING UP OF THE EXISTING STRUCTURE MUST BE MADE GOOD TO THE
PRE - CONSTRUCTION CONDITION OR BETTER.
12 INSPECTION OF COMPLETED WORK IS REQUIRED BEFORE COVERING UP. PROVIDE A MINIMUM
OF 72 HOURS NOTICE TO CONSULTANT.
13 REMOVE AND CLEAN UP ANY DEBRIS OR MATERIAL FROM THE SITE THROUGHOUT THE DURATION
OF THE CONTRACT ON A DAILY BASIS AND UPON COMPLETION OF THE WORK AS DIRECTED BY
THE CONSTRUCTION MANAGER.
14 OBTAIN AND PAY FOR ALL ELECTRICAL PERMITS AND INSPECTIONS REQUIRED FOR COMPLETION
OF WORK AND ACCEPTANCE . PROVIDED CERTIFICATES TO THE CONSTRUCTION MANAGER
VERIFYING THAT THE WORK CONFORMS TO THE REQUIREMENTS OF ALL CODES AND
AUTHORITIES HAVING JURISDICTION.
15 PROVIDE VERIZON WIRELESS WITH A WRITTEN WARRANTY, EFFECTIVE FOR ONE YEAR AFTER
DATE OF ACCEPTANCE, FOR THE COMPLETE INSTALLATION. REPAIR OR REPLACE ANY DEFECTS
ARISING DURING THIS PERIOD AT NO EXTRA COST TO VERIZON WIRELESS.
16. NO DEVIATIONS FROM DESIGN SHOWN ON THESE DRAWINGS IS ALLOWED, WITHOUT WRITTEN
APPROVAL FROM THE CONSULTANT. FAILURE TO OBSERVE THIS RULE MAY RESULT IN
CONTRACTOR CORRECTING THE INSTALLATION AT THEIR EXPENSE.
ABBREVIATIONS:
AFF
AFG
AFS
ALUM
AB
L
ARCH
BTS
BLDG
BM
BOT
B.O.
BOC
BOS
CJ
CLG
CLR
CMU
COL
CONC
CONST
CONT
CTR
DIA /0
DTL
(E)
EA
EJ
ELEC
EL
EQ
EW
EXP
EXT
FD
FIN
FIN FLR
FLR
FTG
GA
GALV
GYP
GB
HM
HOR
HR
HT
HVAC
INSUL
INT
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ABOVE FINISHED SLAB
ALUMINUM
ANCHOR BOLT
ANGLE
ARCHITECTURAL
BASE TRANSMISSION SYSTEM
BUILDING
BEAM
BOTTOM
BOTTOM OF
BOTTOM OF CONCRETE
BOTTOM OF STEEL
CONTROL JOINT
CENTER LINE
CEILING
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONSTRUCTION
CONTINUOUS
CENTER
DIAMETER
DETAIL
EXISTING
EACH
EXPANSION JOINT
ELECTRIC /ELECTRICAL
ELEVATION
EQUAL
EACH WAY
EXPANSION
EXTERIOR
FLOOR DRAIN
FINISH
FINISH FLOOR
FLOOR
FOOTING
GAUGE
GALVANIZED
GYPSUM
GYPSUM BOARD
HOLLOW METAL
HORIZONTAL
HOUR
HEIGHT
HEATING VENTILATION AIR CONDITIONING
INSULATION
INTERIOR
JT
LAM
LF
MANUF
MAX
MECH
MH
MM
MIN
MISC
MPH
MTL
NIC
NOM
NTS
OC
OD
OH
OPNG
OPP
PCS
PR
PSI
PSF
PT
RAD
RD
REINF
REQ'D
RM
RAN
SCHED
SECT
SF
SIM
SQ FT
SS
STD
STL
STRUC
TEMP
THK
T.O.
TOS
TOC
TYP
UNO
VERT
W/
WWM
JOINT
LAMINATED
LINEAL FOOT
MANUFACTURER
MAXIMUM
MECHANICAL
MANHOLE
MILLIMETER
MINIMUM
MISCELLANEOUS
MILES PER HOUR
METAL
NOT IN CONTRACT
NOM INAL
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OVERHEAD
OPENING
OPPOSITE
PERSONAL COMMUNICATION SYSTEM
PLATE
PAIR
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
PRESSURE TREATED
RADIUS
ROOF DRAIN
REINFORCED /REINFORCING
REQUIRED
ROOM
RIGHT OF WAY
SCHEDULE
SECTION
SQUARE FOOT
SIMILAR
SQUARE FOOT
STAINLESS STEEL
STANDARD
STEEL
STRUCTURAL
TEMPORARY
THICK
TOP OF
TOP OF STEEL
TOP OF CONCRETE
TYPICAL
UNLESS NOTED OTHERWISE
VERTICAL
WITH
WELDED WIRE MESH
1.
ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI -318.
2. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH IBC
2006 SECTION 1905 AND ACI 301. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL BE AS FOLLOWS.
TYPE OF CONSTRUCTION 28 DAY STRENGTHS
(fc)
A. SLABS ON GRADE
TOPPING SLABS
CONCRETE PIERS
B, ALL STRUCTURAL CONCRETE
C. CONCRETE FOUNDATIONS
3000 psi
4000 psi
3000 psi
CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE II UNLESS NOTED OTHERWISE.
3. THE CONSTRUCTION MANAGER SHALL SUPERVISE AND BE RESPONSIBLE FOR THE METHODS AND
PROCEDURES OF CONCRETE PLACEMENT.
4. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR - ENTRAINED WITH AN
AIR- ENTRAINED AGENT CONFORMING TO ASTM C260, C494, C618, C989 AND C1017. TOTAL AIR
CONTENT SHALL BE IN ACCORDANCE WITH TABLES 1904 OF THE IBC 2006.
5. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, fy =
60,000 psi. EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE
40, fy = 40,000 psi. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL
CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615(S1) MAY BE WELDED ONLY IF
MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES
SPECIFIED IN AWS D14 ARE SUBMITTED.
6. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH ACI
315 AND 318. LAP ALL CONTINUOUS REINFORCEMENT AT LEAST 30 BAR DIAMETERS OR A MINIMUM
OF 2' -0". PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS
AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2' -0 ". LAP ADJACENT MATS OF WELDED WIRE FABRIC
A MINIMUM OF 8" AT SIDES AND ENDS.
7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185.
8. SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A615, GRADE 60, fy = 60,000
psi.
9. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS
SPECIFICALLY SO DETAILED OR APPROVED BY THE ENGINEER OF RECORD.
10. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS:
A, FOOTINGS AND OTHER UNFORMED 3"
SURFACES, EARTH FACE
B. FORMED SURFACES EXPOSED (#6 BARS OR LARGER) 2"
TO EARTH OR WEATHER ( #5 BARS OR SMALLER)
1 1/2"
C. SLABS AND WALLS (INTERIOR FACE) 3/4"
11. BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS.
12. ' ANCHOR BOLTS TO CONFORM TO ASTM A307.
13. NON - SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL BE MIXED
AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS.
GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH IT IS PLACED (3,000 psi
MINIMUM).
SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR
REVIEW PRIOR TO FABRICATION.
2. STRUCTURAL STEEL DESIGN, FABRICATION, PAINTING AND ERECTION (INCLUDING FIELD WELDING,
HIGH STRENGTH FIELD BOLTING, EXPANSION BOLTS, AND THREADED EXPANSION ANCHORS)
SHALL BE BASED ON THE AISI "SPECIFICATIONS FOR THE DESIGN, FABRICATION, AND ERECTION OF
STRUCTURAL STEEL FOR BUILDINGS" LATEST EDITION. SUPERVISION SHALL BE IN ACCORDANCE
WITH IBC 2006 CHAPTER 17, BY A QUALIFIED TESTING AGENCY DESIGNED BY THE CONSULTANT.
THE CONSULTANT SHALL BE FURNISHED WITH A COPY OF ALL INSPECTION REPORTS AND TEST
RESULTS.
3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS:
TYPE OF MEMBER
A. WIDE FLANGES
B. PLATES, SHAPES, ANGLES, AND RODS
C. SPECIAL SHAPES AND PLATES
D. PIPES
E. STRUCTURAL TUBING
F. ANCHOR BOLTS
G. CONNECTION BOLTS
ASTM A992, Fy = 50 ksi
ASTM A36, Fy = 36 ksi
ASTM A572, Fy = 42 ksi
ASTM A53, Fy = 35 ksi
ASTM A500, Fy = 46 ksi
ASTM A307
ASTM A325
4. ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER ASTM A123 / A123M -00.
5. ALL WELDING SHALL BE IN CONFORMANCE WITH AISC AND VERIZON WIRELESS STANDARDS AND
SHALL BE PERFORMED BY WABO CERTIFIED WELDERS USING E70XX ELECTRODES. ONLY PRE
QUALIFIED WELDS (AS DEFINED BY VERIZON WIRELESS) SHALL BE USED. WELDING OF GRADE 60
REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES.
WELDING OF GRADE 40 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING E70XX
ELECTRODES. WELDING WITHIN 4" OF COLD BENDS IN REINFORCING STEEL IS NOT PERMITTED.
SEE REINFORCING NOTE FOR MATERIAL REQUIREMENTS OF WELDED BARS.
6. COLD- FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE, AND GAGE SHOWN ON
THE PLANS. PROVIDED MINIMUM SECTION PROPERTIES INDICATED. ALL COLD - FORMED STEEL
FRAMING SHALL CONFORM TO THE AISI "SPECIFICATION FOR THE DESIGN OF COLD - FORMED STEEL
STRUCTURAL MEMBERS."
7. BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (3/4 "0) AND SHALL HAVE A
MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. ALL ASSEMBLIES ARE TO BE TIGHTENED IN
ACCORDANCE WITH "SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 ", JUNE
30, 2004. FOR BEARING -TYPE CONNECTIONS, AS A MINIMUM, THE BOLTS SHALL BE TIGHTENED TO
A "SNUG TIGHT" CONDITION. A "SNUG TIGHT" CONDITION IS DEFINED AS THE TIGHTNESS THAT
EXISTS WHEN ALL PLIES IN A JOINT ARE IN FIRM CONTACT. THIS MAY BE ATTAINED BY A FEW
IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT OF A MAN USING AN ORDINARY SPUD
WRENCH.
8. NON - STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8"0 ASTM A307 BOLTS UNLESS
NOTED OTHERWISE.
9. ALL WELDS TO BE 1/4" FILLET UNLESS NOTED OTHERWISE.
10. TOUCH UP ALL FIELD DRILLING AND WELDING WITH 2 COATS OF GALVACON (ZINC RICH PAINT) OR
APPROVED EQUAL.
SPECIAL INSPECTIONS:
LEGEND AND SYMBOLS:
CHAIN LINK FENCE
CEDAR FENCE
POWER
TELCO
POWER/TELCO
COAX
O O
p
T
- T/P
a o
p
TIP - T/P
- COAX COAX
O 0
OVERHEAD POWER - OH - OH - OH
CENTERLINE
REVISION BUG A
ELEVATION VIEW
BUG
ELEVATION
DETAIL BUG
SECTION BUG
T/P -
COAX -
OH
4( DETAIL NUMBER
SHEET NUMBER
,
TOP OF ...
EL 0' -0"
E9--- DETAIL NUMBER
SHEET NUMBER
AltDETAIL NUMBER
SHEET NUMBER
SPECIAL INSPECTIONS IN ACCORDANCE WITH IBC 2006 SECTION 1704.
SOILS /GEOTECHNICAL:
❑SHORING INSTALLATION AND MONITORING
DOBSERVE AND MONITOR EXCAVATION
OVERIFY SOIL BEARING psf BEARING
❑SUBSURFACE DRAINAGE PLACEMENT
❑VERIFY FILL MATERIAL AND COMP ACTION
D VERIFY CONDITIONS AS ANTICIPATED
OPILE PLACEMENT (AUGER CAST/DRIVEN PILE)
❑OTHER
REINFORCED CONCRETE:
❑REINFORCING STEEL AND CONCRETE PLACEMENT
OPRESTRESSED/PRECAST CONCRETE FABRICATION AND ERECTION
❑BATCH PLANT INSPECTION
❑SHOT CRETE
OGROUTING
❑OTHER
STRUCTURAL STEEL:
❑FABRICATION AND SHOP WELDS
❑ERECTION AND FIELD WELDS AND BOLTING
❑OTHER
STRUCTURAL ALUMINUM:
❑FABRICATION AND SHOP WELDS
❑ERECTION AND FIELD WELDS AND BOLTING
❑OTHER
STRUCTURAL MASONRY:
❑CONTINUOUS
❑PERIODIC
OTHER: NONE REQ'D
ANCHORING TO CONCRETE:
DBOLTS INSTALLED IN CONCRETE
❑POST- INSTALLATION ADHESIVE ANCHORS
❑POST- INSTALLATION MECHANICAL ANCHORS
RECEIVED
APR 16 2009
COMMUNITY
PFAIT
verinn wireless
We never stop wo/brg for you.
3350 16181 AVE SE / MS 8221
BELLEVUE. WA 98008
PLANS PREPARED BY:
C. CORNERSTONE
N O I N eealr
INC.
18928 WOODINVILLE - REDMOND RD NE.
SUITE 210
WOODINVILLE. WA 98072
PHONE: (425) 487 -1732 FAX: (425) 487 -1734
EMAIL: cei @cornerstone -engr.com
PROJECT INFO'
SEA RIVERTON
13130 44TH AVE S
SEATTLE, WA 98168
KING COUNTY
ISSUED FOR'
CCONSTRUCTION
REV:= DATE: = DESCRIPTION. =BY._ -
CK: _
04 -14 -09
ISSUE FOR
CONSTRUCTION
JRF
MWO
04 -03 -09
ISSUE FOR
CLIENT REVIEW
LJS
MWO
L DRAWN BY:
CCURRENT ISSUE DATE
LICENSURE•
LJS
CHK.: =APV
I JRF MWO
04 -14 -09
DRAWING INFORMATION
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
DRAWING TITLE'
DRAWING NUMBER'
GENERAL NOTES
G -1
0
CEI JOB NUMBER: 09 -20022
NOTE:
CONTRACTOR IS TO REUSE EXISTING ANTENNA PIPE
MASTS & ANTENNA MOUNTING HARDWARE WHEN
POSSIBLE. NEW ANTENNA PIPE MAST AND MOUNTING
HARDWARE SUPPLIED BY CONTRACTOR TO MATCH
EXISTING.
NOTE:
THIS IS NOT A SITE SURVEY. ALL PROPERTY
BOUNDARIES AND ORIENTATION OF TRUE NORTH HAVE
BEEN OBTAINED FROM A PLOT MAP AND PREVIOUS
DRAWINGS PROVIDED TO CEI BY VERIZON WIRELESS &
ARE APPROXIMATE. NO LANDSCAPING IS REQUIRED
PROPOSED REPLACEMENT PANEL ANTENNA
(TYP OF 1 PER SECTOR, 3 SECTORS)
(E) BUILDING
t• 1
PROPOSED REPLACEMENT PANEL ANTENNA
(TYP OF 2 PER SECTOR, 3 SECTORS)
PROPOSED REPLACEMENT PANEL ANTENNA
(TYP OF 1 PER SECTOR, 3 SECTORS)
(E) METER BOX ON POST
(E) PRIVACY CHAINLINK FENCE W/ BARB WIRE
RELOCATED (E) T -ARM FROM 71' LEVEL
TO 117' LEVEL TO MATCH (E)
(E) EDGE OF ROAD
(E) UTILITY H -FRAME
(E) 3'x3' CONCRETE PAD W/ EQUIPMENT
(E) TREE AREA
(E) (8) PORT ENTRY PANEL
W/ (12) 7/8" COAX (E)
(4) 1 518" COAX NEW
(E) ICE BRIDGE
l W/ (12) 7/8" COAX (E)
(4) 1 5/8" COAX NEW
(E) 120' -0" HIGH STEEL MONOPOLE
verizonwireless
We never stop WDIINIg for you.
3350 1610 AVE SE / MS 0221
BELLEVUE, WA 98008
4
PACIFIC CORPORATION
...PLANS PREPARED BY
C gCORNERSTOo E N c
16928 WOODINVILLE- REDMOND RD NE,
SUITE 210
WOODINVILLE, WA 98072
PHONE: (425) 487 -1732 FAX: (425)487 -1734
EMAIL: cei @cornerstone-engr.com
PROJECT INFO
SEA RIVERTON
13130 44TH AVE S
SEATTLE, WA 98168
KING COUNTY
ISSUED FOR'
CONSTRUCTION
REV: = DATE: = DESCRIPTION: =BY =CK:=
DRAWN BY:
CCURRENT ISSUE DATE
_ LICENSURE
LJS
CHK.: =APV
I JRF MWO
04 -14 -09
= DRAWING INFORMATION:
(E) 5'x11' CONCRETE PAD
W/ GENERATOR
(E) 10' WIDE ACCESS GATE
(E) 4 _WIDE ACCESS GATE
(E) CMU WALL
(E) FOREST LINE
(E) EDGE OF ROAD
r-
RECEIVED
APR 16 2009
COMPOUND PLAN
22x34 SCALE: 1/4" = 1' -0" 111x17 SCALE: 1/8" = 1' -0"
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
DRAWING TITLE'
COMPOUND PLAN
DRAWING NUMBER
. A -1
.0
CEI JOB NUMBER: 09 -20022
QO
04 -14 -09
ISSUE FOR
CONSTRUCTION
JRF
MWO
04 -03 -09
ISSUE FOR
CLIENT REVIEW
LJS
MWO
DRAWN BY:
CCURRENT ISSUE DATE
_ LICENSURE
LJS
CHK.: =APV
I JRF MWO
04 -14 -09
= DRAWING INFORMATION:
(E) 5'x11' CONCRETE PAD
W/ GENERATOR
(E) 10' WIDE ACCESS GATE
(E) 4 _WIDE ACCESS GATE
(E) CMU WALL
(E) FOREST LINE
(E) EDGE OF ROAD
r-
RECEIVED
APR 16 2009
COMPOUND PLAN
22x34 SCALE: 1/4" = 1' -0" 111x17 SCALE: 1/8" = 1' -0"
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
DRAWING TITLE'
COMPOUND PLAN
DRAWING NUMBER
. A -1
.0
CEI JOB NUMBER: 09 -20022
RELOCATED (E) T -ARM FROM 71' LEVEL
TO 117' LEVEL TO MATCH (E)
PROPOSED ANTENNA TIP HEIGHT
TOP OF STEEL MONOPOLE
(E) ANTENNA TIP HEIGHT
TOP OF (E) STEEL MONOPOLE
VeriZenwireless
We new stop ■akhg kryou.
3350 161s1 AVE SE / MS 4221
BELLEVUE, WA98008
=
EL 121' -0" AGL IiII-1IIIi
i
r
-~
-
Q
EL 120' -0" AGL
(E)
Ili
I
i EL 12V -0" AGL
"i1
PACIFIC CORPORATION
EL 120' -0" AGL "1II
PROPOSED VERIZON WIRELESS
REPLACEMENT PANEL ANTENNA SEE O
,
I .,,
ills
III
it
y.
_ii
1
\ (E) COLLAR MOUNT ,Q
pIl!
(E) ANTENNA ARRAY
(E) ANTENNA TIP HEIGHT
�
I'
.I
EL 117' -0't AGL r
1
��I
(E) 120' -0" STEEL MONOPOLE
CONTRACTOR TO RE -USE (E) PIPE MAST,
T -ARMS 8 MOUNTING HARDWARE @
117 -FOOT LEVEL IF COMPATIBLE @ ALPHA &
BETA SECTOR, OTHERWISE PROVIDED BY
PLANS PREPARED BY
�E Or7Nt STONE
_� Or 14 EERra INC.
18928 WOODINVILL E 2EO MOND RD NE,
WOODINVILLE. WA 98072
PHONE: (425) 487 -1732 FAX: (425) 487 -1734
EMAIL: cei@cornerstone <n9r.com'
SHEET A -3 FOR MODELS 8 LOCATIONS
(E) ANTENNA ARRAY
(E) ANTENNA ARRAY
(E) ANTENNA ARRAY
VV
II��l.
III
II
f j
11
CONTRACTOR TO RE -USE (E) PIPE MAST,
T -ARMS & MOUNTING HARDWARE IF
COMPATIBLE, FROM 71 -FOOT LEVEL @
ALPHA & BETA SECTOR, OTHERWISE
PROVIDED BY CONTRACTOR TO MATCH (E)
(E) 120' -0" STEEL MONOPOLE
PROPOSED (4) ADDITIONAL 1 5/8" COAX
ROUTED INSIDE POLE TO MATCH (E)
'
(E) TREE (TYP)
PROJECT INFO.
SEA RIVERTON
13130 44TH AVE S
SEATTLE, WA 98168
• KING COUNTY
IV EL 75 %0" AGL
CONTRACTOR TO MATCH (E)
-
(E) ANTENNA TIP HEIGHT
1 (E) COLLAR MOUNT
EL 73' -6" AGL
I1111I
(E) ANTENNA ARRAY
•
I
_ _
I EL 71' -0 "± AGL
1 (E) TREE (TYP)
ISSUED FOR
CONSTRUCTION
_
REV:= DATE: = DESCRIPTION:— BY: =CK: —.
*
�1 T'7
TS
r
I� `: _
M }r
Y " �� y, r�
(E) ANTENNA ARRAY
l____
/i
r fir:
•x°
A
} I
QO
04 -14 -09
ISSUE FOR
CONSTRUCTION
JR. F
MWO
A
04 -03 -09
ISSUE FOR
CLIENT REVIEW
LJS
MWO
rDRAWNBY
CHAP
US I JRF MWO
CURRENT ISSUE DATE:
04 -14 -09
_LICENSURE
(E) LANDSCAPE
r
_+
ar � 1,.
.fd:
� _ �.F`. 5"
(E) LANDSCAPE •
1�7¢
YS;�.
E <P
`pLCi WYhO
c
1 EXPIRES 02175/10
_��' 1•�
- .�It♦!�I� �I►...
DRAWING INFORMATION
Ir1.L-
"Li'
tix i.`• '`. 6�'�t •�r1'''��S�`
•' ���' f� tra I
t�
GRADE r }i.?t ?.... •• }
_
I
` I
ni
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
II.oII
+ +: i
,,. ` �y f
I v..:
'I
' UMW 6billow
�.= ====__ ___ _:___:
- ii�'r'; "`•
C
'•. F• sF
Ai GRADE v I lC <,. r...... 1. ...
'r''':'ti' +.}
y ti
I
L
,_
Mau EL 144' -0" AMSL (0' -0" REF)
(E) C MU WALL
(E) EQUIPMENT SHELTER
(E) CHAINLINK FENCE W/ BARBS EI �/ /E®
G
(E) ICE BRIDGE (TYP)
APR 16 2009
IV EL 144' -0' AMSL (0' -0' REF)
(E) CMU WALL
(E) EQUIPMENT SHELTER
(E) CHAINLINK FENCE W/ BARBED WIRE
(E) ICE BRIDGE (TYP)
—DRAWING
TITLE:
EXISTING & PROPOSED
SOUTH ELEVATIONS
NUMBER.
DRAWING
A_2
0
PROPOSED SOUTH ELEVATION
2
EXISTING SOUTH ELEVATION ccr►nnnuNrTM
- oEmaait auT
CEI JOB NUMBER: 09 -20022
22x34 SCALE: 1/8" = 1' -0" 11x17 SCALE: 1/16" = 1' -0"
22x34 SCALE: 1/8" = 1' -0" 11x17 SCALE: 1/16" = 1-0"
8" 11"
verizonWlf @BSS
We newt stop working for you
335BEL UWA 98908 1 MS 221
LL
LE VU E: ,
°
• VERIZON ANTENNA INFORMATION
SECTOR
QTY.
TIP HEIGHT
FT. AGL
ANTENNA
LENGTH
AZIMUTH
MECHANICAL
DOWN TILT
NO. OF
COAX RUNS
COAX
SIZE
ANTENNA
•
ALPHA
1
±121' -0"
8'
346°
3°
2
+ 4 DIPLEXERS
7/8"
SEE DETAIL 3a
2
±121-0'
4'
346°
1°
2
7/8"
SEE DETAIL 3b
FRONT
. .
-
��
rJ
SIDE
BACK
'S=2 'S=2
0
4" •
,---,--- ,---,---
r
L'
r,
SIDE
B
e,
BACK
•
PACIFIC CORPORATION
1
±121-0"
8'
346°
0°
2
7/8"
SEE DETAIL 3c
BETA
1
±121-0"
8'
106°
3°
2
+ 4 DIPLEXERS
7/8"
SEE DETAIL 3a
FRONT
•
d
SIDE
BACK
E3
E3
2
1121' -0"
4'
106°
1°
2
7/8"
SEE DETAIL 3b
PLANS PREPARED
1
±121' -0"
8'
106°
0°
2
7/8"
SEE DETAIL 3c
BY.
C�ORN�STONE
_� ER1140, N
18928 WOODINVILLE- REDMOND RD NE,
SUITE 210
WOODINVILLE, WA 98072
PHONE: (425)487 -1732 FAX: (425)487-1734
EMAIL cei(¢`cornerstone -engr.wm
GAMMA
1
±121' -0'
8'
226°
0°
1
1 5/8'
SEE DETAIL 3a
2
±121-0"
4'
226°
0°
+ 2 DIPLEXERS
1 5/8'
SEE DETAIL 3b
1
±121-0"
8'
226°
0°
1
1 5/8"
SEE DETAIL 3c
=
PROJECT INFO'
8 6
FRONT
SEA RIVERTON
13130 44TH AVE S
SEATTLE, WA 98168
KING COUNTY
COAX LENGTH SCHEDULE
NOTE:
SECTOR
LENGTH
# COAX
DIAMETER
COAX ROUTING TO MATCH EXISTING COAX ROUTE
TOP
�� °
ALPHA
±130'
6 (E)
7/8"
�tt 1
TOP TOP
ANTENNA "a" ANTENNA "b" ANTENNA "c"
BETA
±130'
6 (E)
7/8"
GAMMA
±130'
4 (NEW)
1 5/8"
ISSUED FOR:
CONSTRUCTION
_I
REV:= DATE: = DESCRIPTION:= BY: =CK:_
ANTENNA AND COAX SCHEDULES
4
PROPOSED ANTENNAS
3
22x34 SCALE: NTS 111x17 SCALE: NTS
22x34 SCALE: NTS 111x17 SCALE: NTS
ANTENNA
ANTENNA "b" —
1‘i
ALPHA
ANTENNA "b "
ANTENNA "a' ��
VI �%
ANTENNA "c' ', O O
• � •F�`p
"c"
[ANTENNAa'
X11
!-
* r•
`•
�ii� ANTENNA "b"
ALPHA
AT 75' -0"
ALL ALPHA SECTOR PANEL TIP HEIGHT
ANTENNAS TO BE REPLACED
r
,)
•, •lpf
O ��
CONTRACTOR TO RE -USE (E)
PIPE MAST, T -ARMS & MOUNTING •
��
IF HARDWARE COMPATIBLE 117ALPHAB BETA
�° a
SECTOR, OTHERWISE PROVIDED
BY CONTRACTOR TO MATCH (E) 4`I
6
��
C�
\��% �'-
P� AT GAMMA
TIP HEIGHT
ALL GAMMA SECTOR PANEL
ANTENNAS TO BE REPLACED
((��
�7
•
���
°,° O •
�Np
+� �'�•
•
�
�,
'�••7
01
•.•
V
!-
1-e
ALL BETA SECTOR PANEL ANTENNAS TO BE REPCED
�p •��
'
fin/ f
%
•,+
42 /,yur
H' /08°
,�'� BETA
AT 7S -6"
TIP HEIGHT
•
"�.
•
RECEIVED
APR 16 2009L
Q04
-14 -09
ISSUE FOR
CONSTRUCTION
JRF
MWO
Q
04 -03 -09
ISSUE FOR
CLIENT REVIEW
LJS
MWO
[
[LICEN
•
DRAWN BY: CHK.: =APV
LJS I JRF MWO J
CURRENT ISSUE DATE
04 -14-09
SURE
ELK of w• O/
�4, 4,
' c'
�i.
,
P • zza
FGISTE
SS +aNALE�'�
��/
CONTRACTOR TO RE -USE (E)
PIPE MAST, T -ARMS & ( )
MOUNTING HARDWARE IF
COMPATIBLE, FROM 71 -FOOT .
LEVEL @ ALPHA & BETA ••;
SECTOR, OTHERWISE PROVIDED
`I
BY CONTRACTOR TO MATCH (E) {� -
ANTENNA "b"
131,‘/'
�,Z;.
Q'���J GAMMA
ANTENNA "b
ANTENNA
O ��
`
��� -- �/•
•
,
• -�
"a"
p
r /1I _
u
��'. �/ki,, 106°
BETA
/
r'
ANTENNA "b"
J.
ANTENNA "c"
EXPIRES 02/15/10
DRAWING INFORMATION
DO NOT SCALE DRAWINGS, CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
DRAWING TITLE
ANTENNA PLAN AND DETAILS
DRAWING NUMBER
_
A3
0
PROPOISED ANTENNA
2
EXISTIN ANTENNIAXPSAN, DEVELOPMENT
1
CEI JOB NUMBER: 09 -20022
SPLEA /N_1-0
22x34 SCALE:
/G
/4 -,-0
•
•
CITY OF TUKWILA
Department of Community Development WIRELESS TELE-
6300 Southcenter Boulevard, Tukwila, WA 98188 COMMUNICATION
Telephone: (206) 431 -3670 FAX (206) 431 -3665
E -mail: tukplan @ci.tukwila.wa.us FACILITIES
NAME OF PROJECT /DEVELOPMENT: lefej (Zc/1 W t ! e, j ' - SS s v J
'0-01
LOCATION OF PROJECT /DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block
and subdivision, access street, and nearest intersection.
13t 3 o 44-1-k ftte s .
LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement).
3 4 ("t 2-00 5 et- C
DEVELOPMENT COORDINATOR :
The individual who:
• has decision making authority on behalf of the owner /applicant in meetings with City staff,
• has full responsibility for identifying and satisfying all relevant and sometimes overlapping
development standards, and
• is the( primary contact with
the City, to wh all notices tnd/�reports will tbe�segt.
Name: 1� 1 C�E� -- �2Gt ICJ 7i (9� W I/ 'mac L° ss
Address: �. ■, ` �49 ■/ u-)4__Qg l V 6
Phone: 1? FAX:
n
E -mail: (
Signatur
P: \Planning Forms \ Applications \2007 Applications \WCFApp- 12- 07.doc
Date:
RECEIVED
APR 1 6 2009
§tViPMi T
December 7, 2007
APPLICATION
FOR STAFF USE ONLY Permits Plus Type P -WCF
Planner:
File Number: Lo g —
b 1 Co
Application Complete
(Date: )
Project File Number:
Application Incomplete
(Date: )
Other File Numbers:
NAME OF PROJECT /DEVELOPMENT: lefej (Zc/1 W t ! e, j ' - SS s v J
'0-01
LOCATION OF PROJECT /DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block
and subdivision, access street, and nearest intersection.
13t 3 o 44-1-k ftte s .
LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement).
3 4 ("t 2-00 5 et- C
DEVELOPMENT COORDINATOR :
The individual who:
• has decision making authority on behalf of the owner /applicant in meetings with City staff,
• has full responsibility for identifying and satisfying all relevant and sometimes overlapping
development standards, and
• is the( primary contact with
the City, to wh all notices tnd/�reports will tbe�segt.
Name: 1� 1 C�E� -- �2Gt ICJ 7i (9� W I/ 'mac L° ss
Address: �. ■, ` �49 ■/ u-)4__Qg l V 6
Phone: 1? FAX:
n
E -mail: (
Signatur
P: \Planning Forms \ Applications \2007 Applications \WCFApp- 12- 07.doc
Date:
RECEIVED
APR 1 6 2009
§tViPMi T
December 7, 2007
COMPLETE APPLICATION CHECKLIST
The materials listed below must be submitted with your application unless specifically waived in writing the
Department of Community Development. Please contact each Department if you feel that certain items are
not applicable to your project and should be waived. Application review will not begin until it is determined
to be complete. ADDITIONAL MATERIALS MAY BE REQUIRED.
The initial application materials allow project review to begin and vest the applicant's rights. However, the
City may require additional information as needed to establish consistency with development standards.
City staff are available to answer questions about application materials at 206 - 431 -3670 (Department of
Community Development) and 206- 433 -0179 (Department of Public Works).
Check items
submitted
with
application
Information Required.
May be waived in unusual cases, upon approval of both Public Works and Planning
APPLICATION MATERIALS:
Items 1 -9 are required for ALL Wireless Telecommunication Facilities.
✓
1. Application Checklist (1 copy) indicating items submitted with application.
IA.
, Completed Application Form and drawings (5 copies).
tVdepicts
3. Four sets of plans prepared by a design professional. The plans shall include a
vicinity map, site map, architectural elevations, method of attachment, proposed
screening, location of proposed antennas, and all other information which accurately
the proposed project. Minimum size is 8.5" by 11 ". Plans shall be no greater
than 24" x 36 ".
4. Application Fee Type I ($240), Type II ($490), or Type IV ($2,435).
✓
''
Completed and notarized Affidavit of Ownership and Hold Harmless Permission to
Enter Property (1 copy attached).
WAto
6. SEPA Environmental Checklist. SEPA is not required when the facility: •
i) Is a microshell and is to be attached to an exiting structure that is not a residence or
school and does not contain a residence or a school;
ii) Includes personal wireless antennas, other than a microcell, and is to be attached to
an existing structure (that may be an existing tower) that is not a residence or school
and does not contain a residence or school, and the existing structure to which it is
be attached is located in a commercial, industrial, manufacturing, forest or
agriculture zone; or
iii) Involves constructing a personal wireless tower less than sixty feet in height that is
located in a commercial, industrial, manufacturing, forest, or agricultural zone.
7. A letter from the applicant describing the proposed project and describing compliance
with the City's Code requirements.
014
8. Sensitive Area studies and proposed mitigation (if required).
1/A
9. If an outdoor generator is proposed, a report prepared by an acoustical engineer
demonstrating. compliance with TMC Chapter 8.22, "Noise ".
P: \Planning Form s \Applications \2007 Applications\ WCFApp- 12- 07.doc
December 7, 2007
If the application requires a Type II review these additional items are needed:
A' / ^
V(J
10. Four sets of photo simulations that depict the existing and proposed view of the
proposed facility;
11. Materials board for the screening material;
12. Landscaping plan;
13. Letter from a radio frequency engineer that demonstrates that the facility meets
Federal requirements for allowed emissions;
14. If the facility is located within a residential zone, a report from a radio frequency
engineer explaining the need for the proposed wireless communication facility at that
location. Additionally, the applicant shall provide detailed discussion on why the
wireless communication facility cannot be located within a commercial or industrial
zone.
If th application requires a Type IV review these additional items are needed:
15. A narrative responding to the criteria at TMC Section 18.58.060.
16. The radio frequency engineer report shall include a discussion of the information
required under TMC Section 18.58.070. The report shall also explain why a tower must
be used instead of any of the other location options outlined in Table A.
17. Engineering Plans for the proposed tower.
18. A vicinity map depicting the proposed extent of the service area.
19. A graphic simulation showing the appearance of the proposed tower and ancillary
structures and ancillary facilities from five points within the impacted vicinity. Such
points are to be mutually agreed upon by the Director of DCD and applicant. All plans
and photo simulations shall include the maximum build -out of the proposed facility.
20. Evidence of compliance with Federal Aviation Administration (FAA) standards for
height and lighting and certificates of compliance from all affected agencies.
21. Evidence that the tower has been designed to meet the minimum structural standards
for wireless communication facilities for a minimum of three providers of voice, video or
data transmission services, including the applicant, and including a description of the
number and types of antennas the tower can accommodate.
PUBLI NOTICE MATERIALS:
22. Payment of a $365 notice board fee to FastSigns Tukwila or
Provide a 4' x 4' public notice board on site within 14 days of the Department determining that a
complete application has been received (see Public Notice Sign Specifications Handout).
23. Payment of a $105 mailing label fee to the City of Tukwila or
Provide two (2) sets of mailing labels for all property owners and tenants (residents or businesses)
within 500 feet of the subject property. Note: Each unit in multiple - family buildings - -e.g.
a artments, condos, trailer parks - -must be included (see Public Notice Mailing Label Handout).
N,_
4. If providing own labels King County Assessor's map(s) which shows the location of each
property within 500 ft. of the subject lot.
P: \Planning Forms \ Applications \2007 Applications\ WCFApp- 12- 07.doc
December 7, 2007
STATE OF WASHINGTON
ITY OF TUKWILA
Dep meat of Community
Development
6300 Southcenter Boulevard, Tukwila,
WA 98188
Telephone: (306) 431 -3670 FAX (306)
431 -3665
E -mail: tukplan a ci.tukwila.wa.us
AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS
PERMISSION TO ENTER PROPERTY
RECEIVED
`APR 16 2009
COMMUNITY
DEVELOPMENT
ss
COUNTY OF KING
The undersigned being duly sworn and upon oath states as follows:
1. I any the current owner of the property which is the subject of this application.
2. All statements contained in the applications have been prepared by me or my agents and are true and correct to the best of my
knowledge.
3. The application is being submitted with my knowledge and consent.
4. Owner grants the City, its employees, agents, engineers, contractors or other representatives the right to enter upon Owner's real
property, located at 13130- q �(fh Taicth I a s ( } elk $ for the purpose of application
review, for the limited time necessary to complete that purpose.
5. Owner agrees to hold the City harmless for any loss or damage to persons or property occurring on the private property during the
City's entry upon the property, unless the loss or damage is the result of the sole negligence of the City.
6. Non - responsiveness to a City information request for ninety (90) or more days, shall be cause to cancel the application(s) without
refund of fees.
EXECUTED at 3e.(lWL&
On this day personally appeared before me
executed the foregoing instrument and acknowledged that h slle signed the same as hi
purposes mentioned therein.
SUBSCRIBED AND SWORN TO BEFORE ME ON THIS (601 DAY OF Ap 1 i
(city), 0r4- (state), on APAii 16
Tina D. CR.ui is 0 Ue d
(Print Name) le S,4&#
Lin'li
15'4'00 $e . • aA2
(Address) Belle-my W f}- Q'' ril
4 $ --60 -6 &'3
(Phone Number) Vj
(Signature)
,20 O
ZO rdess c16fc
Nine( 3 P
Ma, D. Leor'S
to me known to be the individual who
oluntary act and deed for the uses and
SHIRLEY A. VANGEN
NOTARY PUBLIC
STATE OF WASHINGTON
COMMISSION EXPIRES
SEPTEMBER 29, 2011
NOTARY PUBLI
residing at
a.
, 20 Of
in and for the Stahl of Washington
Bellow
My Commission expires on
P: \Planning Forms \Applications \2007 Applications\ WCFApp- 12- 07.doc
'q(aq(Qo1/
December 7, 2007
Cry of Tukwila. r
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http../A.vww.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R09 -00589
Initials: JR
Payment Date: 04/16/2009
User ID: 1659 Total Payment: 842.89
Payee: ODELIA PACIFIC CORP
SET ID: 0416 SET NAME: VERIZON WIRELESS
SET TRANSACTIONS:
Set Member
D09 -057
L09 -016
TOTAL:
Amount
592.89
250.00
592.89
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA - - - 842.89
TOTAL: 842.89
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
ZONING /SUBDIVISION
000/322.100 356.60
000/345.830 231.79
640.237.114 4.50
000/345.810 250.00
TOTAL: 842.89