HomeMy WebLinkAboutPermit D13-005 - NGUYEN RESIDENCE - REMODELNGUYEN RESIDENCE
5016 WALLACE ST
D13-005
City diP Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 20643 1-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
Parcel No.: 3348400775
Address: 5016 WALLACE ST TUKW
Suite No:
Project Name: NGUYEN RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D13-005
Issue Date: 01/15/2013
Permit Expires On: 07/14/2013
Owner:
Name: NGUYEN JOSEPH T+MARY H
Address: 322 SENECA PL NW , RENTON WA 98057
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S ; SEATTLE WA 98108
Contractor:
Name: G & G SPECIALTY CONTRCTORS INC
Address: 4633 S 36 ST , PHOENIX AZ 85040
Contractor License No: GGSPEGS919RT
Lender:
Name:
Address:
r
Phone: 206 296-7437
Phone:' 480-921-4079
Expiration Date: 12/31/2013
DESCRIPTION OF WORK:
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE - WORK TO POTENTIALLY
INCLUDE SELECTIVE REPLACEMENT OF WINDOWS, SELECTIVE REPLACEMENT OF INTERIOR/EXTERIOR DOORS WITH NEW
ACOUSTICAL DOORS, INSTALLATION OF SECONDARY SLIDING GLASS DOORS AND SKYLIGHTS, ETC.
Value of Construction: $35,359.00 Fees Collected: $1,239.61
Type of Fire Protection: International Building Code Edition: 2009
Type of Construction: VB Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
**continued on next page**
doc: IBC -7/10
D13-005 Printed: 01-15-2013
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private:
Storm Drainage:
Street Use: Profit: N
Water Main Extension: Private:
Water Meter: N
Permit Center Authorized Signature:
Date:
Public:
Non -Profit: N
Public:
I hereby certify that I have read and ex- • this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied ether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or • r rformance of worm authorized to sign and obtain this development permit and agree to the conditions attached
a-
to this permit
Signature:
Print Name:
�f O%2
null and void if the work is not commenced within 180 days from the date of issuance,or if the work is
This permit shall become o ysuspended
or abandoned for a period of 180 days from the last inspection.
Date: l�- .-
PERMIT CONDITIONS:
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431-3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D13-005 Printed: 01-15-2013
this requirement.
•
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D13-005 Printed: 01-15-2013
r
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Building Permit No.
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.: 3348400775
Site Address: 5016Wallace St.
Tenant Name: Mary and Joseph Nguyen
Suite Number:
Property Owners Name: Mary and Joseph Nguyen
Mailing Address: 322 Seneca PI. NW
Floor:
New Tenant: 0 Yes ® ..No
Renton
WA
98057
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296-7437
Seattle WA
98108
E -Mail Address: Sharyn.Parker@kingcounty.gov
City State
Fax Number: (206) 269-7315
Zip
GENERAL CONTRACTOR INFORMATION -
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number: Expiration Date:
City
Day Telephone:
Fax Number:
State
Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody@smstemper.com or tim@smstemper.com
City State
Day Telephone: (206) 624-2777
Fax Number: (206) 624-2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
H:\Applications\Porms-Applications On Line\2009 Applications\I-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 1 of 6
S
BUILDING PERMIT INFORIVTATION — 206-431-3670
Valuation of Project (contractor's bid price): $ '—? Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? 0 Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers 0 Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System – For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\For ms -Applications On Line\2009 Applications\I-2009 - Permit Application.doc
Revised: 1.2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1st Floor
973
2"d Floor
766
3rd Floor
Floors thru
Basement
973
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers 0 Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System – For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\For ms -Applications On Line\2009 Applications\I-2009 - Permit Application.doc
Revised: 1.2009
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER111 U — S RIZED AGENT:
Signature.
Print Nam
imothy J. Fenlason, SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Date: 1/7//
Day Telephone: (206) 624-2777
Seattle
WA 98106
City
State
Zip
Date Application Accepted:
O, ,il n
Date Application Expires: /A
I 01
I (3
Staff Initials:/�
H:\Applications\Forms-Applications On Line\2009 Applications\I.2009 - Permit Application.doc
Revised: 1-2009
bh
Page 6 of 6
4111
PLUMBING AND GAS PIPING PERMIT INFORMATION — 206-431-31r1O
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detaed information):
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
er:
Indicate type of plumbing fixtures and/or gas piping ogle s being instal and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
F' ture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
lothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
• ater Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater an.. r vent
Ind' trial waste treatment
inter .tor, including trap
and ve except for kitchen
type gre. - interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Repair . alteration of
water .tping and/or water
tre.. ent equipment
Repair or . eration of
drainage or -nt piping
Medical gas piping
system serving 1-5
inlets/outlets for a
specific gas
Each additional medical
gas inlets/outlets greater
than 5
: ackflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protect e device
other than atmosph • is -type
vacuum breakers ov
inch (51 mm) diamete
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuu t
breakers not included i
lawn sprinkler backfl.
protections (1-5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:\Applications\Forns-Applications On-Line\2009 Applications \1-2009 Permit Application.doc
Revised: 1-2009
bh
Page 5 of 6
City o'ukwilar
Department of Community Development
6300 Southcerter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: htip:/Svww.ci.tulnvila.wa.us
SET RECEIPT
•
RECEIPT NO: R13-00124
Initials: JEM
Payment Date: 01/09/2013
User ID: 1165 Total Payment: 13,045.45
Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE)
SET ID: S000001897 SET NAME: KING COUNTY NOISE ABATEMENT
SET TRANSACTIONS:
Set Member Amount
D13-004 1,018.34
D13-005 1,239.61
D13-006 1,313.36
D13-007 779.67
D13-008 1,116.68
D13-009 1,141.27
D13-010 1,313.36
D13-011 1,092.10
D13-012 1,239.61
D13-013 1,092.10
M13-003 167.70
M13-004 186.50
M13-005 177.10
M13-006 167.70
M13-007 177.10
M13-008 177.10
M13-009 124.25
M13-010 177.10
M13-011 167.70
M13-012 177.10
TOTAL: 'T918 :'31
119, 01-t . L -
TRANSACTION LIST:
Type Method Description
Amount
Payment Credit C VISA 13,045.45
TOTAL: 13,045.45
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
000.322.100 6,849.15
City ifirukwilar
Departmen of Community Development
6300 Southcenter Boulevard, Suite 11100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: hip :/tuww. ci. tukwila. wa,us
STATE BUILDING SURCHARGE
640.237.114 45.00
TOTAL: 13,045.45
INSPECTION RECORD
Retain a copy with permit
DI3-ocS
INSPECTION NO. PERMIT NO. f✓
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 ', (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:11
AL5
Type f-I�nsm.5tion: t CO
r.
Address: �.6 i W t W A t t AT ce
Date ,) J I S' ( t' -/
Special Instructions:
/
a.m.
Date Wanted —2-S —13 /m
Requester:
Phone No: I,] —(31
(31 m
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
p_tf-w. ( (..0kki9Ce,te,
•
d p ,i
\
)
....-."
? /
F '
,...)
I
A - p.hf - li
7
J
J
--
t I ." .
Inspector:
v
Dater
n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
Jennifer Marshall
From:
Sent:
To:
Cc:
Subject:
Tim Fenlason <tfenlason@jonespayne.com>
Tuesday, January 08, 2013 11:29 AM
Jennifer Marshall
sharyn.parker@kingcounty.gov; Jesse Holgate
Re: KCIA RANRIP Submittal
You are correct. I'd like you to change the applications to reflect the amounts in the pink column. I thank you
for this extra work and if you'd like, I can gladly drive to your office to make the changes.
On Tue, Jan 8, 2013 at 9:56 AM, Jennifer Marshall <Jennifer.Marshall@tukwilawa.gov> wrote:
Good morning Tim,
Due to the fact that I cannot just arbitrarily change information on permit applications, I am clarifying the direction you
are giving me. Are you directing me to update the valuations provided on the applications submitted yesterday to the
numbers below under the column highlighted pink and labeled "Value Originally Provided?"
Applicant Name
Ochoa Residence
Nguyen Residence
Aragon Residence
Aragon Residence
Carter Residence
Christensen
Residence
Fasano Residence
Kerr Residence
Nguyen/Diem
Residence
Rivera Residence
Address
11863 44 Av
S
5016 Wallace
St
4610 S 124 St
12245 46 Av
S
11802 40 P1 S
12212 48 Av
S
12029 44 Av
S
3834 S 116 St
11620 40 Av
S
11826 44 P1 S
Dev Permit Value Provided on
No Application
D13-004 $24,018.00
D13-005 $31,135.00
D13-006 $32,099.00
D13-007 $17,201.00
D13-008 $25,472.00
D13-009 $28,169.00
D13-010 $37,403.00
D13-011 $23,133.00
D13-012 $33,129.00
D13-013 $23,619.00
Value Originally
Provided
$26,622.00
$35,359.00
$38,407.00
$30,978.00
$31,174.00
$38,918.00
$29,764.00
$35,722.00
$29,761.00
If these numbers are correct please respond accordingly and I place a copy of these emails in the file proving that I have
been authorized to make the changes. If they are not correct, please provide me with the correction valuations.
Thank you,
Jennifer Marshall
Permit Technician
Original Message
From: Tim Fenlason[mailto:tfenlason@jonespayne.com]
Sent: Monday, January 07, 2013 4:18 PM
1
To: Jennifer Marshall
• •
Cc: sharyn.parker@kingcounty.gov; Bill Rambo; Jesse Holgate
Subject: Re: KCIA RANRIP Submittal
Jennifer,
My preference would be to use the amount provided to Bill and to update the applications. I know that the amounts
provided to Bill are correct, as I did those calculations myself.
On Mon, Jan 7, 2013 at 4:08 PM, Jennifer Marshall <Jennifer.Marshall@tukwilawa.gov> wrote:
> Good afternoon Tim,
> I received the applications and plans for ten lots for the above
> referenced project. I have completed the data entry in our permit
> system and discovered there are discrepancies with valuations provided
> to Bill Rambo and the valuations provided on the applications. I have
> attached a spreadsheet showing those discrepancies. The issue with
> there being a difference is that the permit estimate provided from
> Bill is no longer applicable.
> It is the end of my work day, so I will wrap this up tomorrow morning
> (I probably will not be able to fit it in until about 10 am) and
> provide the updated permit fees which will correspond with the new
> valuations given. At that point we will need payment to be made
> before the permits can begin the review process. I have also attached
> the original worksheet you and Bill were working with for your reference.
> Have a good evening.
> Jennifer Marshall
> Permit Technician, City of Tukwila
> T: 206 431-3670, F: 206 431-3665
> jennifer.marshall@tukwilawa.gov
Tim Fenlason Associate AIA
Senior Job Captain
2
HERMIT COORD COPS
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: D13-005 DATE: 01/07/12
PROJECT NAME: NGUYEN RESIDENCE
SITE ADDRESS: 5016 WALLACE ST
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # after Permit Issued
DEPARTMENTS:
Building Division
Public Works
Tliv\G OLV.i4"
Fire Prevention ■
Structural
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete ❑
DUE DATE: 01/10/13
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
TUESITHURS ROUTING:
Please Route E6 Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 02/07/13
Not Approved (attach comments) ❑
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Contractors or Tradespeople .Printer Friendly Page
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite/Apt.
City
State
Zip
County
Business Type
G f& G SPECIALTY CONTRCTORS INC
4809214079
4633 S 36Th Street
Phoenix
AZ
85040
Out Of State
Corporation
Parent Company G & G SPECIALTY CONTRCTORS INC
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
602975812
Active
GGSPEGS919RT
Construction Contractor
12/31/2009
12/31/2013
General
Unused
Business Owner Information
Name
Role
Effective Date
Expiration Date
GOODBALLET, CHARLES ELMER
Chief Executive Officer
12/28/2009
Bond Amount
WAVY, CHRISTINE
Chief Operating Officer
12/28/2009
59BSBEA9058
59BSBEA9058
GOODBALLET, JAMES SCOTT
President
12/28/2009
GOODBALLET, TERESA LYNN
Secretary
12/28/2009
INS CO OF THE WEST
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
4
FIRE INS
HA2 CO
59BSBEA9058
59BSBEA9058
12/18/2010
Until Cancelled
$12,000.0001/03/2011
11/16/2012
1
INS CO OF THE WEST
2278440
12/18/2009
Until Cancelled
$12,000.00
12/28/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
4
Companion
Property a Cas
Ins C
PCP10000270101
11/03/2012
11/03/2013
$1,000,000.00
11/16/2012
3
National Union
Fire Ins of PA
PCP1000027
11/03/2011
11/03/2012
$1,000,000.00
12/27/2011
2
LEXINGTON INS
CO
4392611702
12/31/2010
12/31/2011
$1,000,000.0001/11/2011
1
LEXINGTON INS
CO
4392611701
12/31/2008
12/31/2010
$1,000,000.0001/14/2010
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
01/15/2013
KI
NG
COU
NTY INTERNATIONAL AIRPORT
I:E:TI,/.,L, AIRCRAFT NOISE
REMEDY IM
PROVEMENTS PROGRAM
SCOPE 0
F WORK
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE.
MECHANICAL VENTILATION; NE CONTRACT INCLUDES ALL INFORh1ATION IN NE DRAWINGS AND
SPECIFICATIONS INCLUDING BUT NOT LIMITED TO:
APPLICABLE
YES N'
I. SELECTIVE REPLACEMENT OF EXISTING WINDOWS. WITH NEW VINYL -FRAMED ACOUSTICAL WINDOWS.
X.
2. CUT DOU)I OF WINDOWS TO COMPLY WITH EGRESS` REQUIREMENTS
X.
3. INFILL OF EXISTING OPENINGS:
X
4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS.
X
5. INSTALLATION. OF STORM DOORS:.
X
6. INSTALLATION OF SECONDARY SLIDiNG GLASS DOORS.
X.
1. INSTALL4TiON. OF SECONDARY SKYLIGHTS,
X
8. INSTALLATION OF PET DOORS.
.
X
9. INSTALLATION OF FIREPLACE FRESH AIR vENT.
X
10. INSTALLATION OF CHIMNEY CAP.
X.
11. REGULATED MATERIALS ABATEMENT.:
X
12.. ATTIC VENT BAFFLES.
13. INSTALLATION OF ATTIC INSULATION.
X
14. INSTALLATION OF MECHANICAL VENTiLATION EQUIPMENT, BLENDING AIR UNIT AND
ASSOCIATED DUCTING.
X
15. INSTALLATION OF MECHANICAL vI_TITILATION:EQUIPMENT, -FURNACE MODIFiCATION AND
ASSOCIATED DUCTING.
X
16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATiON.
X.
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCHITECTURAL MODIFICATIONS,
X
18. INSTALLATION OF SMOKE DETECTORS..
X.
I. NEW ELECTRICAL PANEL / SERVICE.
X
20,01015 AND TUBE WIRING.
X
SEPARATE PERMIT
REQUIRED FOR:
Mechaniad
ertlectrical
IPiumbinp
as Piping
City of Tukwila
ib1LD NG DIVISION
FILE COPY
Permit No.
PI- r-lgaw approval is subject to errors and omissions.
t ; ` („ n3truction documents does not authc&&&e
A) _ , VI adopt;�,,,, e or ordinance. Rec pt
o, i , v v i�le! `� w :r, ,'I is acknowledged:
Date: 1 -IC "
City Of Ybrkwila
BUILDING DIVISION
REVISIONS
No changes shall be made to the scope
cf work without prior approval of
Tukwila Building Division.
i'C'T : I 'tits on; will require a new plan submittal
I C rJ may include additional plan review fees. 1
C00747C12 BI
D PACKAGE 1\it
33
353-0058-044
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of Seattle, WA
APPLICABLE CODES:
2005 International Residential Code,
International Fire Coda,
International Mechanical Code
3348400115
,ZONING 6F1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTiON TYPE: (No Changer
V B NON SPRINKLERED
LEGAL DESCRIPTION.
LOT 33, BLOCK 11, C.D. HILLMAN'S MEADOW GARDENS ADDITION, TO THE CITY OF SEATTLE, DIVISION NO. 2, ACCORDING
TO THE PLAT THEREOF, RECORDED IN VOLUME 12 OF PLATS, PAGE(S) S2, IN KING COUNTY, WASHINGTONt EXCEPT THAT
PORTION OF SAID LOT 33, IF ANY LYiNG WITHIN PRIMARY STATE HIUi-IWAY NO.
T0.0 TITLE SHEET, PROJECT INFO.
Alm` FLOOR PLANS 4 NOTES
A2.0 WINDOW TYPES, SCHEDULE 4 DETAILS
4.1 DOOR TYPES, SCHEDULE 4 DETAILS
A22 MISCELLANEOUS DETAILS
A23 WINDOW FLASHING DETAILS
MI.O LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES :t DWG INDEX
M2.0 MECHANICAL PLANS AND DETAILS
M2.1 MECHANICAL PLANS. AND DETAILS
E1.0 ELECTRICAL FLOOR; PLANS AND NOTES
EI.1 ELECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTO
RY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 913108
Ph: 206. 263. 9233
Fax: 206.296.0190
Contact: Sharyn Parker
Ir -mall. Sharyn.Parkerekingcounty.gov
ARCHITECT:
Sit Stamper Architects P.L.L.C.
4000 Delridge Way SW, Suite 200
Seattle, WA 98106
Ph: 200. 024..71T
Fax. `206.624.2913'
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E-mail: jorrylsmstempeccom
melodyesmstemper:cgn
timesmstamper.com
ACOUSTICAL INEER:
SSA Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206.. 839. 0819
Fax: 206.839.0824
Contact: Mohamed Alt Allaoua.
-mail: mohamedessaacoustics.com
MECHANICAL ENGINEER:
The r Greenbusch Group
1300 West Nickerson St.,, Suite 201
Seattle; WA 98119
Ph 206.318..086S
Fax: 206: 318 0641
Contact:: Dylan Turner
E-mail: DylanTegreent use cam
ELECTRICAL ENGINEER:
Tres West Engineers
2102 S. 42nd Street, 'Suite 301
Tacoma, WA 98409
Ph: 253 412. .000
Fax: 253. 412. 3463
Contact: Brent Rollins
E-mail:: bcretreswest.com
REGULATED MATERIALS:.
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Fh: 206. 232. 5635
Fax 206.162.4180
Contact: Tim Ogden
E -mall: tim_:ogcdenepbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
'123 North Washington St. 0200
Boston, MA 02114
Contact: Tim Fenlason,
Cynthia Maeda
E-mail: CMaedaejonespayne.eom
VICINITY MAP (NTS)
STRUCTURAL ENGINEER
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 98121
Ph: 206.622.4580
Fax. 206, 622.0422'.
Contact: Ron Martinson
E -mall: ronnepsm-engineers.com.
REVIEWE1 FOR
CODE COMPLIANCE
APPROVED
►JAN 1 I lryfi
�v - r'ERMi
ENTER
BUILDINGDME It N
G OED
FC TUEKWULU
IJAN ,0 7 20131
NORTH
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELR]DGE WAY SW
SUITE 200 SEATTLE, WA 98196
(206): 024-2777- FAX (2(18) 624-2973
JUNE 7; 2012
0810.03.2134
NTERNATIONAL AIRPORT
MPROVEMENTS
z
Lu
AIP NUMBER
3-53-0058-044
TUKWILA WASHINGTON
DATE
JUNE 7, 2012
ISSUED
100" CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
:DRAWN.
LB&.CP
PROJECT
INFORMATION,
DRAWING
INDEX,
DIRECTORY
T0.0
0810.03.2.134
A. SOUTH ELEVATION
II
I
II
5I
FAMILY
ROOM
PRIOR TO COMMENCING WITH DEMOLITION
A "pre -demo inspection" is required.
Contractors shall provide documentation that
an "asbestos survey" has been completed. If
needed, abatement procedures per "Puget
Sound Clean Air Agency" shall be completed
and documentation of compliance shall be
provided at time of final inspection.
1/4" =
SPECIAL NOTES:
LAN
5
NOTE:
LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01:1101
AND 02 83 00.
NOTE:
KNOB AND TUBE WIRING PRESENT..
MAIN FLOOR PLAN
1/4"=1'-0"
GENERAL NOTES
I. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM N RESIDENCE FROM 5:00 Ml TO 8•.00 AM EACH
DAY. HOMEOWNERS WILL WAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS N THE RESIDENCE FOR WEEKENDS
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS:
5. DOORS OR WINDOWS SCHEDULED TO 13E REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN S:00 AM AND 5:00' PM.
6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
1. ADD SOLID WOOD BLOCKING AT WINDOWS.
B. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
3 EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST 13E PROVIDED.
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
I1. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 50 AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS WATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
I5. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
Ib. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
Ii. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK. REFER TO ELECTRICAL
FOR TIMER LOCATION
IS INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL, SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS: REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS SHEET.
1S. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36 CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20. MAXIMi"I POWER OUTAGE IS EIGHT HOURS. POWER MUST RE PROVIDED AT RESIDENCE BEFORE 8:00 All. 4 AFTER 55:00 P.M.
B. WEST ELEVATION
!BEDROOM
4
BATH 3
BEDROOM
3
134TH 4
EXIST: ATTIC
ACCESS PANEL
'I l
UPPER FLOOR PLAN
PLAN KEYNOTES
1 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY.. REF. WINDOW SCHEDULE.
C) DEMOLISH EXISTING DOORS), FRAME; CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND
STORR`T DOOR REF. DOOR SCHEDULE.
0 3 DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A22 FOR DETAIL. COORDINATE WITH
CMECHANICAL DOCUMENTS.
) INSTALL NEW SECONDARY SLIDING GLASS DOOR. REP.. DOOR SCHEDULE.
CBLENDING UNIT LOCATED AND INSTALLED IN (E)CRAWL SPACE, i� MECH. FOR UNIT, REF..' ELECT., FOR SPEED CONTROL AND
J DISCONNECT. REF. 3/A2.2 FOR DETAIL.
BLENDING UNIT LOCATED ADJACENT TO NEW HATCH INSTALLED N ATTIC, REF. MECH. FOR UNIT, REF. ELECT, FOR SPEED CONTROL
V,:1 AND DISCONNECT. REF. 3/A22 FOR DETAIL.
C)Z COORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION
DETAIL.
OCOORDINATE FLOOR GRILL WITH: MECHANICAL DOCUMENTS.
0 COORDINATE CEILING GRILL WITH MECHANICAL. DOCUMENTS.
10 INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF 51 -ENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL DOCUMENTS.
Il INSTALL VENT !BAFFLE(S) AT EXISTING GABLE END VENT(S) N ATTIC. REF. 4/A22 FOR DETAIL.
12 INSTALL NEW ELECTRICAL PANEL. COORDINATE WITH ELECTRICAL DOCUMENTS.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK 1N OR BLOCK ACCESS TO I -HOMEOWNER DRIVEWAY.
C. NORTH ELEVATION
r
D. EAST ELEVATION
Illlllhllllll
0
I—
I' I'
' IEXISf. ATTIC rv' 7 1
IlAI ,CCESS P'•ANEIL I•
I
At
-1 1
•
•
I_ \` A 1A all, I I 1. 1 i':J I
i st 1 1 I I• -- ma y •
i /- - - �'� .._.- -n:- - - I - - L..I . . 1.1 ... i . .
V -
A Ai fib
I I -� / 1!
L .s, I- .- ' - - - _ i
--- J4__^___
-Ii-
• AL
▪ AL
T . . . . . 1.1 . . I. • .rte. .
f N- A- \-
24'-3"
ATTIC PLAID
1/4"= 1'-0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 11 inn
LEGEND
City of Tukwila
BUILDING DIVISION
J
r
RECEIVED
CIN OF TUKWq q
1 JAN .0 7 2013
PERMIT CENTER
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR
REFER TO POOR SCHEDULE
EXTERIOR STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
IIIIIIIIIIIII
6
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE
FEATHER TEXTURED CEILING OVER AT A
MN. OF 24" FROM EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING. DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
REF. MECH. 4 ELECT.
REF. GENERAL NOTE II
ATTIC INSULATION
ATTIC INSULATION DAM
SD . INSTALL. BATTERY OPERATED SMOKE
DETECTORS
(DI
15461
INSTALL BATTERY OPERATED SMOKE
CARSON MONOXIDE DETECTORS
GAS METER
SOFFIT FOR MECHANICAL DUCTING
1%)1•;-•,. nos
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4.000 DELEIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
4220
REGISTERED
F,
JUNE 7, 2012
0810.03.2134
0
0
—J
Z
O
Z
w
F-
z
.4'
E--'
z
0
0
0
Z
MPROVEMENTS
>-
0
w
2
cew
w
C/)
0
F -z
LL
U
ce
AIP NUMBER
3-53-0058-044
O
I
0
I—
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
NOTES
A1 .0
0810.03.2134
WINDOW TYPES : • •
T
2.
DOUBLE -HUNG CASEMENT
•Z. -011N
3.
SLIDER / FIXED / SLIDER
FIXED
5.
HORIZONTAL
XX SLIDER
WINDOW SCH
EDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
DETAIL
SET
LIVING ROOM
2"4"
• STAN/STAIN.:
8
LIvINGIVOM
2-3 x3"40.'"
STAN/STAN
SAFETY GLAZING REQUIRED
SAFETY GLAZING REQUIRED
1/A2...c
KITCHEN
S
• 4'-0"
STAN/STAIN
1/A2.0
E
KITCHEN
BEDR0011 1
11"1-1" K 'CIO"
-,.4V-ll" IW)
STAIN/STAIN..
STAIN/STAIN
2/A20:
42.0
F
•IBEDROom
4
IS x
STAIN/STAIN.
INSULATED GLASS UNIT SAFETY GLAZING REQUIRED
1/A7.0.
G
LIVING ROOM
3
311.10111
STAIN/STAIN
I/42.0
.11
LIVING ROOM
47T"
STAIN/STAIN
sAFETY GLAZING REQUIRED
1/A2 0
BEDROOM 2
2'-4" x 41--1°
STAIN/STAIN
1/A2,0
BEDROOM 7:
2
2'-S"
STAIN/STAIN,.
1/A7.0
K
L
BEDROOM 3
BEDROOM 3
2
21-911 x V -S"
T-4" x
STAIN/STAIN
STAIN/STAIN
1140
UAW
M
sEpRocm 4
3
3'-l�"
STAIN/STAIN
1/42.0
N
FAMILY ROOM
21-3" x
STAIN/STAIN
INSULATED GLASS UNIT SAFETY GLAZING REQUIRED
3/42.0
FAMILY ROOM
5
• 4!•-40" 31.511
STAIN/STAIN
sAFETy GLAZING REQUIRED
3/A20
FAMILY ROOM
5
4'-10"
31511.
STAIN/STAIN.
SAFETY GLAZING REQUIRED
3/A2.0
Q
FAmLy ROOM
.5
r -11" :x 2'-0."
STAN/STAIN,:
SAFETY GLAZING REQUIRED
• 3/42.0
TYPICAL WINDOW.SCHEDU.LE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 088000., ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN. TEMPERED GLASS, BUT SHALL BEAR.
IDENTIFICATION AS SAFETY RATED GLAZING PER: CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS,
3, HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
4. FOR HEAD FLASHING INSTALLATION REFER TQ HEAD FLASHING
DETAIL 'A ON WINDOW TYPES, SCHEDULE &. DETAILS SHEET.
SLOPE
t"nUn.
ti
wEMMED EDGE I
1
r --
END CLOSURE
HEAD FLASHING DETAIL TYP.
= 1' - QII
cAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) T-111 SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REM,. MAINTAIN
(E) COURSING. FAINT MODIFIED SIDING
TO MATCH (E) SIDING.
PRE-pRimED, GAL'? SHEET METAL
FLASHING W/ END aosuRE UNDER
SELF -ADHERING MEMBRANE. COLOR
TO BE SELEcTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AN PAINT TO MATCH (E) TRim.
coLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
REMOVE (E) T -III SIDING FOR
INSTALLATION OF NEW. WINDOW TRIMS
AND REATTAOMEIT OF (VOIDING TO
WINDOW OPENING FRAMNO. LIFT (E)
WALL UNDERLAYMENT AND INSTALL
WINDOW / NAILING FLANGE OVER SELF
ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER
NAILING: FLANGE. LAP -L.Ap UNDER (E)
WALL UNDERLAYMENT. CAULK NEW.
VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PAINT .MODIFIED SIDING
TO MATCH. (E) SIDING
(E) T-111 SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
TRIM- MATCH (E) TRIM. PRIME.' ALL
SIDES AND PAINT TO. MATCH CE)
TRIM. COLOR TO BE: FIELD
DETERMINED
BACKER ROD I SEALANT
ACOUSTICAL WINDOW ASSEMBLY
WINDOW HEA
D
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
TOUCI-I UP PANT,
AS REM"
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD. JAMB LINING. FINISH To
MATCH (E)
SEALANT 4 BACKER ROD
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
ACOUSTICAL
WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAIL FLANGE
TRIM- mATcH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO EEI FIELD DETERMINED
REMOVE (E) T-111 BIDING FOR
INSTALLATioN OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR
RE. INSTALL SIDING AS REM,. PAINT
MODIFIED SIDING To MATCH (E)
BIDING
(E) EXTERIOR •SHEATHING
WI
N
M
B
T-111 SID
3" = 1' - 0"
WINDOW SILL
NG —WI
N
DOW DETA
(E)Gue
TOUCH UP PAINT,
AS REM"
CONTINUOUS
SEALANT, Typ.
SHIM AS NECESSARY
FILL GAP LW BATT
INSULATION
BACKER ROD 4
SEALANT
3/4" WOOD SILL
..:SOLID WOOD -TRIM
L SET
CONTINUOUS
SEALANT, rno.
TOUCH UP PANT,
AS REO'D
SELF ADHERING
MEMBRANE
(E) GWB
(E) WD. SIDING
7 i
CAREFULLY LIFT CE) WALLUNDERLAYMENT I 1I
AND INSTALL SELF -ADHERING MEMBRANE \I 1 H
PENETRATION FLASHING. LAP (E) WALL
uNpERLAYmENT OVER PENETRATION
FLASHING TYP AT HEAD AND JAMB&
REMOVE CE) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REOID. MAINTAIN
(E) COURSING.. PAINT MODIFIED SIDING
To MATCH (E) SIDING
PRE -PRIMED, GAL'? .SHEET METAL
FLASHING. W/ END CLOSURE UNDER
SELF -ADHERING mEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE HELD DETERMINED
BACKER ROD I SEALANT
- GWS
CE)WALL UNDERLATMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
CONTINUOUS
sEALANT, Typ.
LID WOOD TRIM
•110. JAMB LINING
ACOUSTICAL WINDOW ASSEMBLY
REMOVE (E) WD. SIDING FOR
INSTALLATION OF NEW WINDOW TRIMS
AND REATTACHMENT OF (5) SIDING To
WINDOW OPENING FRAMING. LIFT (E)
WALL UNDERLAYMENT AND INSTALL
WINDOW 1 NAILING FLANGE OVER SELF
ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER.
NAILING FLANGE AND LAI:, UNDER (E)
WALL
UNDERLAYMENT. CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL
•HEADS FLUSH. PAINT MODIFIED SIDING
TO MATCH (E) SIDING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR. SHEATHING
WIN
DOW HEAD
SEALANT
SHIM AS. NECESSARY
FILL GAP' W./ BATT
INSULATION:
L
(E) WB
ONTNLIOLIS
SEALANT, TY.p.
BACKER ROD 4 SEALANT
•AcoLISTIc,41.. WINDOW ASSEMBLY
AcousTpAL WIND.... OW ASSEMBLy
BACKER ROD' 4 SEALANT
WINDOW NAILING FIN
MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
REMOVE CE) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) coURSNG. PANT MoDIFIED SIDING
TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) up SIDING
I
[7] r1J11
lk I
WINDOW JAMB
WINDOW SILL
WOOD WINDOW
3" = -
SOLID WOOD TRIM
WD JAMB. LINING
SEALANT
SHIM AS NECESSARY
FILL GAP LU/ EsArt
INSULATION
BACKER ROD 4
SEALANT
3/4"
3/4" UP. SILL - STAN T.O.
MATCH (E)
SOLID WOOD TRIM
CONTINUOUS
SEALANT, nr.
SELF -ADHERING
MEMBRANE
(E) GU)I5
DETAIL SET
CAREFULLY LIFT CE) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLAsHiNG. rrp AT HEAD AND JAmBs.
REMOVE (E) WoOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR Re
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PANT MODIFIED SIDING
TO MATCH (E) SIDING.
(E) EXTERIOR. SHEATHING
FRE -MIMED, GAL'? SHEET METAL
FLASHING WI END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH CE) TRH.
COLOR TO BE FIELD DETERMINED
BACKER. ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
EXISTING NAILER
EXISTING CONC. WALL
REMOVE (E) UP. SIDING 'FOR INSTALLATION
OF NEW WINDOW. TRIMS AND REATTAcAMENT
OF (E) SIDING TO WINDOW OPENING FRAMING,
LIFT CE)WALL UNDERLAY ENT AND INSTALL
WINDOW 1 NAILING FLANGE OVER. SELF
ADHERING MEMBRANE PENETRATION.,
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER NAILING
FLANGE AND LAP UNDER (E) WALL
UNDERLAYMENT. CAULK NEW VERTICAL
SIDING JOINTS 4 SET NAIL HEADS FLUSH.
PAINT MODIFIED SIDING TO MATCH (E)
SIDING
(E) WOOD SIDING
(E) WALL UNDERLAYMENT
(E) I/2" EXT. SHEATHING
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E)
TRIM. COLOR. TO BE FIELD
DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW. ASSEMBLY
AcousTicAL WINDOW ASSEMBLY
BACKER ROD AND SEALANT
WINDOW HEAD
.
4
SELF ADHERING MEMBRANE
CONTINUOUS
SEALANT, nr.
SOLID WOOD TRIM
ttp.. JAMB LINING
SEALANT 4 BACKER ROD
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
CONTINUOUS
SEALANT, TYP.
WINDOW JAMB
SOLID WOOD TRIM
UP JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL. GAP W/ BATT
INSULATION
TRIM- MATCH (E) TRIM. PRIME ALL SIDES
AND PANT TO MATCH (E) TRIM. COLOR TO
BE FIELD DETERMINED
SELF -ADHERING MEMBRANE
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TR1m. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
TO MATCH (E) SIDING
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN ii will
City of Tukvilla
BUILDING DIVISION
WOO.
3" = 1' -
WINDOWSILL
D SIDING — WINDOW DETA
3/4" LLD. SILL - STAIN TO
MATCH (E)
CONTINUOUS.
SEALANT, TYP.
2"x0" PRESSURE TREATED
WOOD
(5-)
CONCRETE WALL
bt3.--cos
L SET
RECEIVED
Cm OF TuwAntA
IJAN 072013
lhoor cki„,
S.MSTEMPER
ARCHITECTS
A PYofessional Limited Liability Company
40.00 DELIRIDG1E WAY SW
SLUE 200 • SEATTLE, NA 98106
(20t) 624-2777 • FAX (206) 624-2973
• ..0.20 .
• iii.f:QI$TE:i0.))..,
JUNE 7, 2012
0810.03.2134
0
0
ctCO
w
0
ce
02
›-
www2
z
co
w
F-
0
z
KING -COUNTY
z0
/k1P NUMBER
3-53-0058-044
z
0
DATE
JUNE 7, 2012
ISSUED
10% co
PROJECT ARCHITECT
JO
PROJECT MANAGER
MLATF
DRAWN
LB&CP
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
.0810.03,2134
DOOR TYPES
FLUSH Sclll
Wf RECTANGLE •LITE AND
4 PANELS
W/ SAFETY GLAZING
UN OBSERVATION PORT
8
SECONDAIRY SLIDING
GLASS DOOR
SAFETY GLAZING
FLUSH SCUJ EXTERIOR
2 LITES, •4 PANELS SINGLE LEAF STORM
W/ SAFEr( GLAZING UJ/ SAFETY GLAZNG
DOO
R SCHEDU
LE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB LEVER
SET
.LOCK
SET
DETAIL
SET
A
3' -On x (01-1311
;•STAINt
HUH .1 TS
PK -4
LOCK -1
2
'ROOM •
.4-1111
I/A2.1
2/A2.1
1/42.1
3
FAMILY ROOM
314017441.....06
STAIN/ VAN
HUH 1'7*
DK -4
LOCK -1
4
LIVING ROOM
ID
34.06x61._r
1/42.1
5
MILT ROOM.
D
TYPICAL.DOOR SCHEDULE. NOTES •
WHERE SAFETY GLAZING BUT NOT $;:DHEDIAEDIN
SECTION 088000 ALL VNIAMINATED -.GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED, LAMINATED :GLAZING PANELS NEED
NOT CONTAIN TEMPERED ,GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER 'CODE,
2. SLIDING. GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY:REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINAL FINISH 'SELECTIONS FOR DOORS
AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO STARTOF WORK
5. FOR HEAD.FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET.
r
14EMMED EDGE I
SLOPE
1
END CLOSURE
HEAD FLASHING DETAIL TYP.
= 1' - 0"
(E) UI OIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF-ADHERKG MEMBRANE
PENETRATION FLASI-ING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
rrp AT HEAD AND JAMBS.
RpiDyg.::(g).woop,siDING fOR
INSTAI_I_Ancist 'OF Ngw.:DOole AssEmmy
4WP-T:RirtxpLACE OR 'RE INSTALL
SLIDING AS REO'D..MANTAR (E)
COORS:NG, PAINT MODIFIED alma TO'
MATCH (E) SIDING.
•PRE4PRIMED, GALV SHEET METAL
FLASHING Wf END CLOSURE UNDER:
SELF.APHERNG MEMIBRANE COLOR TO
13E SELECTED IN THE FIELD'
CONTINUOUS. SEALANT EHIND Z DAR
E.
0ToR1 DOOR PER SCHEDULE.
SELF -ADHERING
MEMBRANE
2" MIN.
(E) EXTERIOR SHEATH
CONTINUOUS.
SEALANT, TYP.
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
NSTALLATIGN
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
REMOVE (E) WP. SIDING FOR INSTALLATION
OF NEW DOOR TRIMS AND REATTACHMENT
O (E) SIDING TO DOOR OPENING FRAMING.
LIFT (E) WALL UNDERLAYMENT ANP INSTALL
SELF ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK
New VERTICAL SIDING JONTS 4 SET NAL
14EAOS FLUSH. PAINT Mot SIDING To
M4TCI-1 (E) SIRING
(E) WOOD SIDING
CONTINUOUS SEALANT BEI -IND
Z DAR FRAM
DOOR HEAD
110
(E) EXTERIOR SHEATHNG
CONTINUOUS
SEALANT, TYI°.
EXISTING FRAMING
-- SOLID WOOD TRIM
STORM DOOR PER SCHEDULE
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER-STRIPPING
JAMB BEYOND
WOOD POOR PER SCI-EPULE
DOOR SHOE
2" MIN.
DOOR SWEEP
ALUMNUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING: FLOOR STRICTURE.
'
WOOD SI
3" = 1 - 0"
DOOR JAMB
SHIM AS NECESSARY
FILL- GAP UJIBATT
INSULATION
i-- DOOR PER SCHEDULE
DOOR SILL
DING - DOOR DETAIL SET
(E) WD.: SIDING
PRE -PRIMED, GALV SI-IEET METAL
FLASI-ING UP END CLOSURE UNDER
SELF-API-ERING MEMBRANE. COLOR TO
IBE SELECTED IN THE FIELD
SELF -ADHERING MEMBRANE. TLIRI DOWN
OVER FRONT EDGE OF TRIM. ENSURE
NO MEMBRANE IS vISIBLE IBELoW
FLASHING EDGE
2X TAPERED CAP
REMOVE (E) SIDING TO FACILITATE
INSTALLATION OF FLASHING AND POOR
HEAD ASSEMBLY
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x 501_11, BLOCKING
ARouNp PERIMETER. OF POOR.FRAME
PAINT ALL EXPOSED EDGES To MATcI4
(E) TRIM
SECONDARY SLIDING STM POOR
ASSEMBLY. INSTALL PER MIR
NSTRUCTICNS
(E) BLDG. PAPER
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF -ADHERING MEMBRANE
REMOVE. (E) WOOD SIDING AND
REPLACE AS REQ'D. LIFT (E)
WALL UNDERLAYMENT AND
INSTALL SELF -ADHERING
MEMBRANE PENETRATION
FLASHING, LAP (E) WALL
UNDERLAYMENT OVER TOP a
PENETRATION FLASHING, PAINT
MODIFIED SIDING TO MATCi-I (E)
SIDING. TYP. AT HEAD AND
JAMB5
DOOR HEAD
BACKER ROD AND SEALANT
SELF-ADHEARING MEMBRANE
PLYWOOD
PRE4MIMED,GALV SHEET METAL
FLASHING .UNDER .SELF.ADHERNG
MENISRANE. PAINT COLOR To SE:
SELECTED. IN.. THE: Flew"
CONTINUOUS 2x SOLID BL=ING AROUND
PERIMETER: :QF DOM FRAME., PAINT ALL
EXPOSED EDGES TO MATCH (E) 'TRIM
TRIM:, PANT TO 101ATc4: (E)M111
SELF -ADHERING MEMBRANE
SECONDARY SLIDING STORM DOOR
ASSEMBLY: INSTALL PER tIFG'R INSTRUCTIONS
UJD. TRIM BEY=
SECONDARY SLIDING vow POOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS.
SEALANT
SOLID WOOD LINING. STAN/
PAINT TO MATCH (E) TRItt
(E) PRIMARY SLIDING DOOR
ASSEMBLY.
(E) !BEVELED WD. SIDING
(E) EXTERIOR SHEATHING.
um- (E) WALL UNDERLAYMENT.
LAP NEW UNDERLAYMENT UNDER
(E) UNDERLAYMENT 2" AND
CONTINUE OVER &JONG GLASS
DOOR FRAME
Mk BETUEEN PRIMARY
ANP SECONDARY SLIDING
GLASS pOoR FRAMES
DOOR JAMB
(E) FLOOR/ DECK MATING
KAI -.am NMI
SOLID WOOD LINING. STAIN/
PAINT To MATCH (E) TRIM.
(E) PRIMARY SLIDING
GLASS POOR
(E) SLIDING GLASS
DOOR
(E) Fl1s11814 FLOOR
(E) INTERIOR coNc. SLAB.
OR (E) WD. FLOOR FRAMNG
DOOR SILL.
WOOD SIDING - DOOR DETAI
L SET
3" = 1 ' - 0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 1 1 'nil
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF r w*Ant
I JAN 0 7 2013
ckhi
S.MSTEMPER
ARCHITECTS
Aeraessiolialumited.licariwcbmparly
4000 MUZIDGE WAY SW
81..Tgrg 200 • StATTLE, WA 913100
(206) 624-2777 • FAX (206) 624-2973
0111
1..W.TE ., *p..4..S0INCTON
JUNE 7, 2012
0810.03.2134
MPROVEMENTS
KING COUNTY
AIP NUMBER
3-53-0058-044
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
Jo
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.032134
CAREFULLY LIFT (E) WALL UND.ERLAYMENT
AND INSTALL SELF-ADHERNG MEMBRANE
PENETRATION FLASHING,. LAp (E),WALL
UNDERLAYMENT ovER.PENETRATION
FLASHING. TYP AT HEAP AND JAMBS.
REMOVE (E) WOOD SIDNG.FoR
INSTALLATION 0 vENT:FixTURE AND
FLASHING. REPLACE OR RE INSTALL
SIDING AS 'REM), MAINTAIN (E)
coLASNG. FAINT MODIFIED- SIDING TO
(E)
PRE -PRIMED, GALV. SHEET METAL
FLASHING W/ J. END CAPS UNDER
5ELF-ADHERING MEMBRANE. EXTEND
FLASHING 4" UP WALL, PAINT COLOR TO
BE SELECTED IN THE FIELD
PANT VENTILATION FIXTURE,
COLOR TO 13E SELECTED IN
NE FIELD
EXTERIOR VENTILATION FIxTLIRE.
F. MECH.- PAINT INTERIOR
ACOUSTICAL DAMPING
COMPOUND. SET N MASTIC AT
EXTERIOR TRIM.
REMOVE / REPLACE SIDING AS
REQUIRED.
AIR INTAKE DETAI.
3" = 1 - 011•
(E) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
(E)' EXTERIOR SHEATHING
2) BLOCKING
2X2 CONTINUOUS PRESSURE
TREATED BLOCKING, 4 SIDES
2X BLOCKING
AT EXTERIOR
EXISTING ROOF
(E) Roc* FRAMING
(E) EAvE vENT
BLOM IN CELLULOSE
INSULATION WITH 4 COMBINED
VALUE OF NOT LESS THAN
R-38,
EXIST. WALL
CONSTR.
f
INSULATION DAM DETAIL
3" = - Ou
(2) SIMPSON A-34 • EACH SIDE
PANEL TO SECURE VENT BAFFLE TO
(E) WALL FRAMING
OPEN TOP
EXIST. GABLE
VENT
NEW GALv.
HARDWARE
cLoN
EXISTING
CEILING
STRUCTURE
i" CDX PLYWOOD
AT (3) SIDES
I" OWE1s15 COINING 4103
INSULATION, TYPICAL.
SEcURE WITH PN rrpa
FASTENERS TO PLYWOOD
BACK AND SIDE PANEL
NOTE:
1. AFTER FAI3RICATION, BAFFLE 514ALL BE SECURELY
ATTACHED N
2. NEW BALE SHALL BE AT LEAST AS WIPE AS
NE Extent* VENT OPENING.
GABLE END VENT BAFFLE DETAIL
1 1 /211 = - 0"
FINISH To MATCH (E) PAINT AND
TEXTURE
SOF
X
F
r— — — — — —
1 1
L_
IT DETAI
L
INSULATION DAM
(E) WALL FRAMING
ATTACH 2x3 LEDGER TO EXIST. DEM
ATTACH SOFFIT RUING TO LEDGER.
1 1 /2" =11_0u
DUCTS PER PLAN WITHIN SoFFIT
RE: MECHANICAL
2x2 CONT. NAILER
Gtua- PAINT To MATCH (E)
TEXTURE 4 COLOR oF CEILING.
ENCLOSE DUCTS TIGHTLY, OR
TERMINATE EDGE LU/ ADJ
ARCHITECTURAL FEATURES PER PLAN.
COORDINATE SOFFIT DIMENSIONS WIN
tlECI-IAN CAL
(E) WD FRAME WALL ASSEMesLY
SUSPEND NECI-I UNIT FROM (E)
STRUCTURE IRE: TIECI-IANICAL
MECH UNIT AND DUCTS -
REP MECHANICAL
BLENDINGHAIR UNIT
VERT. CHASE WALL
2x4 FRAMING
DUCT PER MECI-I.
DUCT
ASE- FAINT To
MATCH (E) WALLS
TRIM FNISH FLOOR AND
INDERLAYMENT TO F.O.
(E) WALL. BUTT Vi TYPE
X Gyp TIGHT TO 51.15K.R.
•(E) FLOOR FRAMING
(E) GWI3
DETAIL
HOLD MINI1w11.111, BUT AS REQUIRED To
COORDINATE DUCT W/ (E) FLOOR
MD CEILING FRAMING.
DEm0u5i4 (E) FLOOR
NEW GRILL COORDINATE WITH
MECHANICAL
CHASE SOFFIT DETAIL
5 1 1/2" = - 0"
BEST HERE
ACCEPTABLE
HERE
NoTE: REMOVE EXISTING SMOKE
DETECTORS, CUT AND PATCH CEILING AS
REQUIRED. REMOVE ALL PAINT LINES,
FRovIPE 514EET RoCK, TAPE AND
TEXTURE AND PAINT TO FILL ALL MOLES
LEFT FROM EXISTING CoNcliTioN. PAINT
To MATCH SURROUNDING CONDITIONS.
am WALL
(E) FINISH IFLOOR
DEMOLISH (E) GWE3
(E) FLOOR CONSTRUCTION
FINISH FLOOR
5i" :CPx W0p
2x10 0 IS" O.0
kit'5-006"
REVIEWED FOR
coDitpcpoRtaccE
JAN 11
City of Tukwila
BUILDING DIVISION
SMOKE DETECTOR INSTALLATION DETAIL
3" - 0"
RECEIVE)
CIITv OF r ,w-Alft 4
IJAN 07 2O1
PERmacEN
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELIZIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
JUNE 7, 2012
0810.03.2134
ce
0
•cc
0
z
w
z
KING :COUNTY:_
CO
z
w
w
0
ce
0
2 w
w
0
z
1.1.1
AIP NUMBER
3-53-0058-044
DATE
JUNE
JUNE 7, 2012
IBBI,JED
100% CD
PROJECT ARCHITECT
J
PROJECT MANAGER
MLATF
DRAWN
LB&CP
MISC..
DETAILS
A22
0810.03.2134
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)•
SHEATHING AT JAMBS
AND HEAD
NOTE: REMOVE (E) SIDING 13ACK FROM (E) RO. 45. REGM
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE: AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS. BEEN INSTALLED.
LAP SILL MEMBRANE
FLASHING 2-I/2"
OVER (E) BLDG.
PAPER AT SILL.
EXTEND 1 i" BEYOND
SILL.
R.O. AT EA. END OF
(E) BLDG.
PAPER AT
SILL
(E) SHEATI-IING
CUT SILL
FLASHING 4 FOLD
THROUGH RO. AS
SHOU.N.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
li" MIN
MEMBRANE. FLASHING AT SILL
BUTTERFLY CORNER FLASHING
SCALE: •NTS
LIFT (E) BLDG,
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REM,
(E) SIDING NOT SHOW FOR cLARITT. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
WINDOW NAIL FLANGE;
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE.
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL.
N. \'\,,,,,,\
\„\
1 ) /
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
ELEVATION VI EW
NOTE: INSTALL WINDOW PER MPG!RS SPECIFICATIONS,
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
BEND
ANCHORAGE
NAILS DOW
OVER NAIL
FLANGE, HEAP
oNLy.
(E) SHEATHING
•SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E)soING
NOT SHOILN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOM OVER
FLANGE
FLASHING AT
JAMBS
NOTE: REMOVE (E) aciNG BACK FROM (E) R.O. AS. REQ'D
(E) SIDING NOT WOLIN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING.
HAS BEEN INSTALLED.
L
WHERE REQUIRED, TRIM
(E) BLDG PAPER AT
HEAP 0 PREPARE
FOR INSTALLATION OF
HEAD F ASHING AND
.IJINDOW TRIM
(FOLLCWNG STEPS).
HEAD FLASHING PREPARATION
SCALE: NTS
CE) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM CE) RD. AS REQ'D
(E) SIDING NOT SHORN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING. AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
CUT JAMB FLASHING.
FOLD AROUND WINDOW
OPENING AS SH011.1s1.
EXTEND 1-lall BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE NTS. -
Nom REMOVE (E)SIDING BACK FROM -.(V
CE) SIDING NOT,:SHOWN FOR CLARITY REPLACE AND
OR :INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL SHT. METAL
HEAD FLASHING
U.. ER CV BLDG
PAFER,
TRIMMED EDGE
OF CE)
SWOON
DIAGRAMATICALLY.
(E) SIDING NOT
SWOON FOR
CLARITY,
NAILING FLANGE AND FLASHING.
MEMBRANE F
SCALE: NTS
LASHING .AT JA
MB.
NOTE REMOVE (E) SIDING BACK fROM.tE),Ra REQD
(E) SIDING NOT 61,10LI.N. FOR CLARITY c REPLACE AND
OR, INSTALL New SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLEa,
ALLOW 101OLEARANOE
BETWEEN FLASHING AND
BOT.gpGE OF (E)
I SIDING.
CA) HEAD FLASH
SCALE: NTS
ING IN. ALLATIO
N
(E)151. -DG. PAPER
MEM
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SI4OUR EXTEND
1-1/211 BEYOND
R.O. AT HEAD
AND JAMBS.
ADHERE.
PENETRATION
FLASHING TO
OUTSIDE PACE OF
WALL SHEATHING
(TYR EACH SIDE
OF WALL)
BRANE FLASHING:AT HEAD
SCALE: NTS
NOTE: REMOVE: (E) SIDING BACK FROM (E) RD. AS REQ'D
CE) SIDING NOT SWOON FOR CLARITY. REPLACE AND
OR INSTALL NEW. SIDING AFTER MEMBRANE FLASHING
I4AS BEEN INSTALLED..
, ..................... _ .....
INSTALL I-IEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
v'NYROP-WW:','44
4.6z/d0AP4
0
WINDOW FLASHING. I
SCALE: NTS
NSTALLATION
SHEET METAL HEAR
FLASHING
(E) SIDING
(E) BLDG, PAPER
evizat4 SIDING
INSTALL WO. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT f3ETIMEN WINDOW
TRIM AND SIDING.
VVOOD TR
SCALE: NTS
M INSTALLATION
4
LEAVE I/4" -W GAP
BETWEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD. IN GAP.
GENERAL NOTES:
I: MEMBRANE FLASHING. IS SPECIFIED IN 01 62 00 AS
"SELF APHEARNG MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2; DETAILS "I, 2, AND V' REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5 AND 6" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW WAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS 1 AND S" REFER TO SHEET METAL HEAD
FLASHING.
B; DETAIL S REFERS TO WOOD TRIM AND CAULK
JOINTS.
13--00.5"
REVIEWED FOR
CODE COMPLIANCE
. APPROVED
1JAN 11 -1h44
City of Tukwila
BUILDING DIVISION
RECEIVED
crry OF TtonAnoli
I JAN i0 7 2013
PERMIT CENTE44
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 PELIRIDGE 1VAY SW
SUITE 20 • SEATTLE, WA 95100
(206) 624-2777 F FAX (206) 624-2973
41.:2.20
RE.Q1STE:131,..p•
1111
TEMPER,. -
JUNE 7, 2012
0810.03.2134
ce
0
0
z
0
z
LU
z
KING COUNTY
AIP NUMBER
MPROVEMENTS
›-
0 z
w 0
U -I Z
12C
L1J cf)
CO <
LL.
0 I—
Ct
F -
z
LU
en
LU
ct
3-53-0058-044
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
FLASHING
DETAILS
A2.3
0810 03.2134
ABBREVIATIONS
LEGEND
DRAWING
NDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
CON D
CON T
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
H WS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MEG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SRC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING:: UNIT
ABOVE FINISHED, CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN: SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS.
BELOW FINISHED CEILING
BELOW FINISHED FLOOR,
BOTTOM OF DUCT
THERMAL UNITS PER HOW
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE,
DIAMETER
DIMENSION
DOWN
DRAWING.
EXISTING
EACH, EXHAUST AIR
.ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE:
EXTERNAL 'STATIC' PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE:
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS,
GYPSUM WALLBOARD
HORSEPOWER
HEATING,- VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER 'CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY'
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR,
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE.
ON CENTER
OPPOSED BLADE ,DAMPER.
PHASE
POINT OF. CONNECTION.
POUNDS. PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY _,DIFFUSER.
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SEATTLE RESIDENTIAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT,, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE: CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL. ABBREVIATI
ONS USTED
SYMBOL
Ac>
ABBE
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
OR a.
1
0
X/Y
////,
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
il•••••••••114
DIRECTION
OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG. NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL FLOOR PLANS.
M2.1 DETAILS
GENERAL NOTES
1. THE MECHANICAL l:SYSTEM SHALL: CONSIST OF :ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE 'SPECIFICATIONS., WORK,
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE :.MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM ,COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS: :LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA,. AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION 'WITH ,ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL. BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION. INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (1AISEC) CHAPTER 5, 503.9
REQUIREMENTS
.5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION 'THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6 PROVIDE ALL REQUIRED. ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
a. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH TFIE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 41-0" AFF. UNLESS NOTED OTHERWISE
9. PROVIDE UNIT SYPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 101-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING. AS REQUIRED._
12. MAINTAIN 31-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
HANGERS,
SYMBOL,
XXX
ON
Es]
0
11111_001111
DN
UP
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VD VOLUME DAMPER
RA/EA RETURN AIR OR EXHAUST AIR DUCT
RG RETURN AIR GRILLE
SA SUPPLY AIR OUTLET, SIDEWALL
SA SUPPLY AIR DUCT
RA/EA RETURN AIR OR EXHAUST AIR DUCT
SD
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION — RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
0,0 OR (14) THERMOSTAT
EQUIP ID#\.— EQUIPMENT LOCATION
NG
•
0
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL /.- ELECTRICAL .COORDINATION
ITEM
No.
EQUIPMENT
CONTROL EQUIPMENT
DESCRIPTION
VOLTS
PH
FURN SHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
23:
26
23
26,
N/A
23
26
N/A
REMARKS
BV -1, BV -2
BLENDING UNIT VENTILATOR
120
1
X
1,2
SWITCHES (ON, TIMER)
120
1
X
X
REMARKS:
1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 DISCONNECT SWITCH
BLENDING UNIT VENTILATO
R
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
WATTS
VOLTS
PHASE .
COMMENTS
BV -1
165
.5" WG
32"Lx12.25"Wx8.5"H
76
120
1
1, 2, 3
BV -2
140 .5" WG
32"Lx12.25"Wx8,5"H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WI
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL
TH THE MANUFACTURER.
GRILLE AND -DIFFUS
ER SCHEDULE
MARK
GEM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
SG -1
100
<08" WG
7"
CEILING
ALLGRILLE
1, 2, 4
SG -1
<08" WG
7"
CEILING
ALLGRILLE
1, 2, 4
SG -2
140
‹or
8"
8"
WALL
•ALLGRILLE
I, 2, 4
0G-1
120
<08" WG
7"
WALL.
WALL CAP
1, 2, 3
OG -2
90
<08" WG
7"
7"'
WALL
WALL. CAP
1, 2, 3
RG -1.
26
<Or WG
4"
4"
CEILING
DECO
1, 2, 4
RG -2
25
<08" WG
.41
FLOOR
DECO
1, 2, 4
RG -3
25
<087 WG
WALL
DECO.
1, 2, 4
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
4. BASIS OF DESIGN: AWES
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
70810.03.21,34 BV, -1 -
DOI 0 03.2134
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
I-532
120 CFM
120 CFM
970
1
90 CFM
90 CFM
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE
SECTION 51-51-1508, TABLES M1508.2 AND M1508.3
MINIM
UM DUCT
INSULATIO
N THICK
N
ESS
DUCT LOCATION
MIN. VALUE
NOTES
ON ROOF OR ON EXTERIOR OF B
UILD
NG.
R-8 WITH WEATHERPROOF BARRIER
1,3
ATTIC. GARAGE, CRAWL SPACE, IN WALLS, FLOOR/CEILIN
G
R-8
1,2,3
WITH)
N CONDITIONED SPACE OR IN HEATED BASEMENTS
R-8
1,3
IN CEMENT SLAB OR IN GROUND
R-5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTFIERWISE EXPOSED TO CONDITIONED AIR.
3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWIN
G NOTES:
1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 0111 01 AND 028300 FOR REQUIREMENTS RELATED
TO EXTERIOR WINDOW TRIM PAINT.
'THERMOSTAT/SWITCH HOURSOFOPERATION
SET BV -1 SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
SET BV -2 SWITCH TO OPERATE 1 OF EVERY 3 HOURS,
MECHANICAL VENTILATION
CALCULATION, BV -1
PER WAC 51-51, SECTION M1508.3
QF = QR (&EGR X F)
QR = (FROM TABLE M1508.2) 0.2
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF = 60 / (1 X 1/2) = 120 CFM
b
MECHA
NICAL VENTILATION CALCULATION,
BV -2
PER WAC 51-51, SECTION M1508.3
QF = QR (&EGR X F)
OR = (FROM TABLE M1508.2) 30
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/3
QF = 30 / (1 X 1/3) = 90 CFM
SEPARATE
PERmirAivo
APPROVAL
REQUIRED
RECEIVED
env OF TLI
I JAN 07 2013
PERMIT CENThr,
EXPIRES: 9/08/2012
S.M, STEMPER
ARCHITECTS
ProreFalattal Limbed Liability Compszy
4000 DETRIDGE WAY SW
SUITE 200 SEItTTLE, WA 08I06
e24-21'77 (2N) ast—eirre
THE GREENBUSCH GROUP, INC
**.******)
)
acausnom., / mom a MECHANICAL 13140INERINO
lXO WEST lia.,MNSW SATE 201 SICTLEAt 911119
ma) va-osea (205) 378-0641 FAX
0
RESIDENTIAL AIRCRAFT NOISE RE
AP NUMBER
3-53-0058-044
DATE
06/05/2012
0
ISSUED
100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, 81.
DWG INDEX
M1.0
0810.0:3,2134
SEE
90
SOFFIT, MAXIMUM
12" DEEP, REFER
TO ARCHITECTURAL
ROUTE SUPPLY
DUCT BELOW
RETURN DUCT
ROUTE IN JOISTS
UNDER STAIRS
TYP
5
111=3 43
25
7110
5
TYP
TYP ALL
-140
WALL GRILLES
:r.sASETieNNT
LOWER FLOOR MECHAM
SCALE: 1/4"
TYP
CAL
BASEMENT
KEY TO VEN ILAT1
PLAN
N ZONES
SCALE: NONE
ROUTE IN
CRAWLSPACE
1--4"0 UP
TO RG -2
SEE
pr NORTH
MAIN FLOOR
SCALE: 1/4" = r-0"
M
AIN 'FLOOR
MECHANICAL PLAN
ATT
C
BV -2
NORTH
040. 25 (E) ATTIC
ACCESS HATCH
TO lay -11\
UPPER FLOOR M
SCALE: -114!'
DRAWL
NG NOTES:
ECHANICAL PLAN
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR
3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SRC M1508.6.6.
2, FILTERS: AFTER EQUIPMENT AND SYSTEM CHECKOUT WORK HAS BEEN
COMPLETED AND, PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE
FOLLOWING:
A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT
SYSTEMS WITH NEW FILTERS.
NORTH:
(E) .ATTIC
ACCESS HATCH1
DN
n
ATTIC MECHANICAL PLAN
SCALE: 1
FLAG N
/4"'
OTES:
NORTH
BV -1 AND DUCTWORK ROUTED IN ATTIC. BV -2 AND DUCTWORK ROUTED IN
CRAWLSPACE/LOWER FLOOR. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS WITH
TECHNICAL REPRESENTATIVE.
ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS
SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE
VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51, SECTION M1508.6.4.
COORDINATE FINAL SWITCH LOCATIONS W11-1 HOMEOWNER.
TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL
GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO
ARCHITECTURAL DRAWINGS AND TECHNICAL. SPECIFICATIONS,
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION
THICKNESS SCHEDULE ON M1.0.
SHEETMETAL "Y" FITTING WITH VOLUME DAMPERS.
bot3.005"
SEPARATE
PERMIT AN
APPROVAL°
REQUIRED
RECEIVED
CITY OF TUKWILA
I JAN 07 2013
PERMIT CENTER
EXPIRES: 9/00012
S.M. STEMPER
ARCHITECTS
A Professional Liesits2 flabill4 Cornrow
4000 0ELRIDGE WAY SW
SUITE 200 •• SEATTLE, W 9810
(806) 024-0777 ^ PAX (006) 024-0073
THE GREENBUSCH GROUP, INC
SO ea ea 40 *a
Age "11121180041° SIEVE° tUffE 00022. 110 11111
(206) 576-0602(200) 3711-0041 FAX
ce
0
CL
ce
0
ce
MPROVEMENTS
0
ce
ot)
0
LL
A1P NUMBER
$-534058-044
0
DATE
06105/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
MECHANICAL
FLOOR
PLANS
M20
0810.03.2134
A TTI C
RETURN AIR
DUCT
OUTSIDE AIR
DUCT
HOLD TIGHT TO
STRUCTURE
MOTOR ACCESS
FILTERS ACCESS
SUPPLY DUCT
FIV -1
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
3. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS
HATCH WITH TECHNICAL REPRESENTATIVE
BV -1 INSTALLATION DETAIL
I SCALE: NONE
CAULK
SHEETMETAL
TRANSITION TO
GRILLE NECK SIZE
DUCT PER PLAN
2X BLOCKING
2X BLOCKING
FOAM BACKER
ROD
WALL GRILLE
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL DIFFUSERS AND GRILLES. PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
WALL GRILLE INSTALLATION DETAIL
SCALE: NONE
INSTALL PER THE
MANUFACTURER'S
WRITTEN INS RUCTIONS
RETURN AIR
DUCT
OUTSIDE AIR
DUCT
HOLD TIGHT TO.
STRUCTURE
NOTES:
1. VERIFY UNIT ORIENTATION BEFCREI INSTALLATION.
2. INSULATE ALL DUCT AS SCHEDULED.
CRAWLSP ACE
MOTOR ACCESS
FILTERS ACCESS
SLEEVE AND
ESCUTCHEON
2X BLOCKING
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
GALVANIZED
SHEETMETAL DUCT,
ROUTE PER PLAN
FLOOR GRILLE
FLOOR
2X BLOCKING
FOAM BACKER ROD
NOTES:
1. INSTALL FLOOR GRILLE PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2 SEE PLANS FOR VOLUME DAMPER LOCATIONS.
FLOOR GRILLE
SCALE:: NONE
INSTALLATION DETAIL
SHEETMETAL
TRANSITION TO
GRILLE NECK SIZE
2X BLOCKING
DUCT PER PLAN
CAULK
FOAM BACKER
ROD
WALL CAP OR
SIDEWALL GRILLE
SLEEVE AND
ESCUTCHEON
2X BLOCKING
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORD. W/ARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1 /A2.2 FOR DETAIL
LAT1ON DETAI
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
2X BLOCKING
SLEEVE AND
ESCUTCHEON
GRILLE
NOTES.
1. INSTALL DIFFUSERS AND GRILLES PER
2. SEE PLANS FOR VOLUME DAMPER LOC
3. CEILING SUPPLY INSTALLATION SHOWN,
DUCT PER PLAN
COORDINATE SOFFIT
WITH TECHNICAL
REPRESENTATIVE
FIELD FABRICATE PLENUM
BEHIND CEILING GRILLE
FOAM BACKER ROD
CAULK
2X BLOCKING
FLOOR: OR CEILING JOIST
MANUFACTURER'S WRITTEN INSTRUCTIONS.
ATIONS.
RETURN SIMILAR.
bioos
RECEIVED
CITY OF TtiKwf
I JAN ,0 7 2013,
PERMIT CENTER
ExPIREs:g/o8/2o1.,2
S.M. STEMPER
ARCHITECTS
Profeadonal Limirtori Liability Company
4000 DELRIDGE WAY SW
SUITE 200 SEATTLE, WA 08/00
(200) 8242777 ^FA (288) 234-2072
THE GREENBUSCH GROUP. INC
********
)
)
ADIUSTIC.L. Algal ger t0nEI0
21:1818°1112.9411tEER0
IVA88119
376-0569 (200) 370-0641 FAX
MPROVEMENTS
re
w
KING COUNT
LL
RESIDENTIAL AIR
AIP NUMBER
3-53-0058-044
DATE
z
cn
06/05/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
DETAILS
M2.1
0810.03.2134
ELECTRICAL PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM Sc AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT UNES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO ALL ALL. HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH—IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
ELECT
RI CAL PLAN
NOTES
PROVIDE COMPLETE POWER. AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL
DRAWINGS.
PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE
HOME RUN CIRCUIT TO PANEL—MP AND MAKE ALL CONNECTIONS. COMPLETE SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY
CEILING OR WALL PENETRATION WORK
NEW PANEL REPLACE
EXISTING. INTERCEPT AND
EXTEND EXISTING CIRCUITS
TO NEW BREAKERS: SEE
DETAIL AND PANEL
SCHEDULE
BASEMNNT
NORTH
L
MAI
F
LD ROOM
AT -1 2
LIA1,46
ROON
N 'FLOOR PLAN
1/4" =
ELECTIRICAL LEGENr)
SY141801.
DESCRIPTION
DESCRIPTION
LIGHTING QR POWER PANEL
0
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CMS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL I INDICATES EQUIP GND.
INDICATES ISOLATED GROUND.
MAST, WEATHERHEAD
amessessosesassellp.-
BRANCH CIRCUIT HOME RUN
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNEC
FOR SPECIFIC REQUIREMENTS
DAMPER CONNECTION
ON SCHEDULES
NON—FUSED. DISCONNECT SWITCH
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
SMOKE ID.ElECTOR
ELECTRICAL METER
TIMER OPERATED SWITCH
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UllUTY.
CEILING MOUNTED FIRE ALARM •--VISUAL STROBE. LIGHT
THERMOSTAT
UNE VOLTAGE ME ALARM SMOKE/CARBON MONOXIDE DETECTOR
MECHANICAL / ELECTRICAL COORDINATION
EQUIPMENT
NO.
CONTROL EQUIPMENT
DESCRIPTION
VOLTS
PH
FURNISHED
UNDER DIVISION
NSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
15
16
15
16
15
16
N/A
REMARKS
BV -1
RI ENDING. UNIT VENTILATOR
120
X
SWITCHES (OR4 TIMER),
120
1
X
X
X
1,2
X
REMARKS: 1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 — DISCONNECT SWITCH
METER AND FINAL
CONNECTIONS BY SCL.
INCLUDE ALL UTILITY
CHARGES IN BID.
CONDUIT DN TO PANEL.
PROVIDE NEW METER BASE,
RIGID STEEL MAST,
WEATHER HEAD AND
CONDUCTOR PIGTAILS PER
SCL REQUIREMENTS.
FINAL CONNECTIONS BY
SCL. INCLUDE ALL UTILITY
SERVICE FEES IN BID.
PROVIDE NEW WEATHER
HEAD, MAST GUYS AND
ANCHORS AT EXISTING
LOCATION. PROVIDE
NEW ROOF FLASHING.
TRIM VEGETATION TO
PROVIDE MINIMUM 36P
CLEARANCE AROUND
SERVICE WIRES PER
SCL REQUIREMENTS.
f5EE ROOM
3
77.
:4r1-4 4
tsE DfROOM
2
1
bvik-oos-•
REPAR4re
EFIOTAN
ApprovD
REQuIRALED
RECEIVED
CITY OF TI 11/Wit
'JAN 0 7 2013
,1,40
s.MsTEIVIPER
ARCHITECTS
A Prof esaional Limited Liability Company
4000 DELRIDGE WAY SW
SLOTS 200 • SEATTLE, WA 98106
(208) B24-2777 • FAX (2116) 824-2973
0810.03.2134
AIP NUMBER
5-53-0058-044
DATE
JUNE 7, 2012
ISSUED
• 100%
PROJECT ENGINEER
CHL
PROJECT MANAGER
E3CR..
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.2134
PANEL
MP
LOOM
DENCE
10.000
4204240-vpm., .1 PHASE, 3 ;iimr.)4$:
AC
200 AMP with MSAJN BKR
CKT LOAD DESCRIPTION
EXISTING LOAD
3
6
EXISTING LOI
R EXISTIN G LOAD
15 EXIST
NGLO.
TWE
KVA
A/P
30/2
30/2
30/2
5012
KVA
TYPE
LOAD ON
EXISTING LW
CKT
: •
4
3012.
15 •°•-•-AE).
17EXISTING
19 •
EXIST N GLOAT)
21 EXISTING L.QAD
23 EXIS11NG LOAD
25 EXISTING LOD
27 BLIENIONGUNIT
29 BLENCINGLINIT
31
33
•35
20/1
164.1 t,
;011
20/1
20(1
30/1
30/1
20/1
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
10
12
14
.• ••
18
20
2011 EXISTINGLOAD
20/1„
.„ .„.
. .
PHASELOAD' ;]PHASEAtt.
. . . . . . ...... .
PHASE B=
KVA
EXISTING 40#4
EXISTING LOAD
22
24ii
26
20/1
,
20/1
2011
PROVISION 30 • . 120
.•
.•
30
FROVISION
32
, .
PROVISION . 34.
movn.,* 44,wemenmemervehnove**,
. „
. „
.. ';
,.........,...,,,, • ' .
38
40
42
LOAD TYPE
H.
WH
D.
A
LM
TOTAL LOADS
CON
N. LOAD.
KVA
MVP
COMPUTED LOAD
KVA
MVP
. ......
•,16OLATEa:GR:0,U.N06u0, •LJ,FEEE:ffTHR.0 LUGS' i;:MAIN EKRSHUNTTRIP::
DIRAINTIGRINpowagN.:Ippolig:: . 1:3 DOUSLEIUGS DSERVICE ENTRANM; 'LABEL:: ,INTEGRALIINOS'FLUSH
,
,ESURFACE
REIVIARNSti:
PROVIDE NEW RIGID STEEL.
MAST, WEATHER HEAD AND
CONDUCTOR PIGTAILS PER
SCL REQUIREMENTS.
FINAL CONNECTIONS BY
SCL. INCLUDE ALL UTILITY
SERVICE FEES IN BID.
PROVIDE NEW MAST
GUYS AND ANCHORS
ROOF
PROVIDE NEW SERVICE
DROP FROM POLE TO
HOUSE BY SCL. ALL
--\ FEES PAID BY
CONTRACTOR.
1.
PROVIDE #4CU GROUNDING
ELECTRODE CONDUCTOR AND
GROUND RODS PER CODE.
MAX 10 OHMS TO GROUND
LB
2"C, 3#3/0 CU
METER AND FINAL
CONNECTIONS BY
SCL. INCLUDE ALL
UTILITY CHARGES IN
BID.
PROVIDE METER BASE
PER SCL STANDARD
#DU13-4/NMT;-30
2%, 3#3/O CU.& CND
PANEL MP
200A
120/240
1 -PH, 3W
PROVIDE NEW NEMA -1 S.E.
RATED \PANEL BOARD.
INTERCEPT AND EXTEND
EXISTING CIRCUITS AND
CONNECT TO NEW BREAKERS.
PROVIDE ALL REQUIRED CUTTING: AND PATCHING AS REQUIRED
TO COMPLETE THE WORK AS DESCRIBED ABOVE AND ON
DRAWINGS.
ROUTE CONDUIT EXPOSED ON OUTSIDE OF HOUSE. PROVIDE
STRUCTURAL SOLID 2X6 BLOCKING IN ATTIC FOR MAST.
PROVIDE BLOCKING AND UNISTRUT ASSEMBLIES TO HOLD
CONDUIT AWAY FROM HOUSE SURFACE TO ALLOW FOR EXISTING
CONDITIONS. VISIT THE SITE TO ESTABLISH EXACT CONDITIONS
PRIOR TO BID.
NEW SERVICE DETAIL
SCALE.NONE
‘1 a.005-•
SEPAIIArz,
PERANA
APPROVALT
REQUIRED
EVENED
OF TUKWILA
JAN .0 7 2013
PERMIT CENTER
S.MSTEMPER
ARCHITECTS
A Prolesaioiaal Limited Liability Company
4000 DELBIDGE WAY SW
SUITE 200. • SEATTLE, WA 98106
(206) .624-2777 • FAX (206) 624-2973
U
0810.03.2134
NTERNATIONAL AIRPORT
MPROVEMENTS
AIP NUMBER
5-53-0058-044
DATE
JUNE 7, 2012
ISSUED
100%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.1
0810.0.3.2134