HomeMy WebLinkAboutPermit D13-006 - ARAGON RESIDENCE - REMODELARAGON RESIDENCE
4610 S 124 ST
D13-006
Cityef Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.nov
Parcel No.: 0179000995
Address: 4610 S 124 ST TIIKW
Suite No:
Project Name: ARAGON RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D13-006
Issue Date: 01/15/2013
Permit Expires On: 07/14/2013
Owner:
Name: ARAGON D
Address: 4610 S 124 , SEATTLE WA 98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RDS , SEATTLE WA 98108
Contractor:
Name: G & G SPECIALTY CONTRCTORS INC
Address: 4633 S 36 ST , PHOENIX AZ 85040
Contractor License No: GGSPEGS919RT
Lender:
Name:
Address:
Phone: 206 296-7437
Phone: 480-921-4079
Expiration Date: 12/31/2013
DESCRIPTION OF WORK:
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE - WORK TO POTENTIALLY
INCLUDE SELECTIVE REPLACEMENT OF WINDOWS, SELECTIVE REPLACEMENT OF INTERIOR/EXTERIOR DOORS WITH NEW
ACOUSTICAL DOORS, INSTALLATION OF SECONDARY SLIDING GLASS DOORS AND SKYLIGHTS, ETC.
Value of Construction: $38,407.00 Fees Collected: $1,313.36
Type of Fire Protection: International Building Code Edition: 2009
Type of Construction: VB Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
**continued on next page**
doc: IBC -7/10
D13-006 Printed: 01-15-2013
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
N
N
Number: 0 Size (Inches): 0
Start Time:
Volumes: Cut 0 c.y.
Start Time:
Sanitary Side Sewer:
Sewer Main Extension: Private:
Storm Drainage:
Street Use: Profit: N
Water Main Extension: Private:
Water Meter: N
Permit Center Authorized Signature:
I hereby certify that I have read and ex
governing this work will be complied
Date:
End Time:
Fill 0 c.y.
End Time:
Public:
Non -Profit: N
Public:
d this permit and know the same to be true and correct. All provisions of law and ordinances
hether specified herein or not.
The granting of this permit does not pres - to give authority to violate or cancel the provisions of any other state or local laws regulating
construction orae performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit
Signature:
Print Name:
® It
Date: /—/S* 13
This permit shall become null and vbi
d if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431-3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: All wood to remain in placed concrete shall be treated wood.
7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
doc: IBC -7/10
D13-006 Printed: 01-15-2013
sewer connections, and properly fill orrwise protect all basements, cellars, septic t ;wells, and other
excavations. Final inspection approval We determined by the building inspector ban satisfactory completion of
this requirement.
8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D13-006 Printed: 01-15-2013
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.cLtukwila.wa.us
Building Permit No.
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: 4610 S. 124th St.
Tenant Name: Daniel Aragon
Property Owners Name: Daniel Aragon
Mailing Address: 4610 S. 124th St.
King Co Assessor's Tax No.: 0179000995
Suite Number: Floor:
New Tenant: 0 Yes ..No
Tukwila
WA
98178
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296-7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker@kingcounty.gov
City State
Fax Number: (206) 269-7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
City
Day Telephone:
Fax Number:
Expiration Date:
Contact Person:
E -Mail Address:
Contractor Registration Number:
State
Zip
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody@smstemper.com or tim@smstemper.com
City State
Day Telephone: (206) 624-2777
Fax Number: (206) 624-2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
H:\Applicanons\Fotms-Applications On Line\2009 Applications \I-2009 - Permit Application.doc
Revised: 1.2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price): $ 027099-9-A t Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? 0 Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? , 0 Yes m No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System – For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Fomu-Applications On Line\2009 Applications\I-2009 - Petmit Application.doc
Revised: 1-2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1st Floor
1,630
2nd Floor
3`d Floor
Floors thru
Basement
1,243
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? , 0 Yes m No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System – For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Fomu-Applications On Line\2009 Applications\I-2009 - Petmit Application.doc
Revised: 1-2009
bh
Page 2 of 6
S
PLUMBING AND GAS PIPING PERMIT INFORMATION - 206-431-3670
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1-5
inlets/outlets for a
specific gas
Each additional medical
gas inlets/outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H: Apphcattons\Fotms-Applications On-Line\2009 Applications \1-2009 Permit Application:doc
Revised: 1-2009
bh
Page 5 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNE ' : ��J�'. D AGENT:
Signature:
Date:
Print Name: m• by Fenlason, SM Stemper Architects, PLLC Day Telephone: (206) 624-2777
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
City
State
Zip
Date Application Accepted:
di 1,911 4 ,.
Date Application Expires:
61I 01
I LS
Staff Initials:
H:' ppbcanons\Fomu-Applications On Line\2009 Applications\I-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 6 of 6
City o'ukwilar
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Website. hitp•//wwwci trdavila.wa.us
SET RECEIPT
RECEIPT NO: R13-00124
Initials: JEM
Payment Date: 01/09/2013
User ID: 1165 Total Payment: 13,045.45
Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE)
SET ID: S000001897 SET NAME: KING COUNTY NOISE ABATEMENT
SET TRANSACTIONS:
Set Member Amount
D13-004 1,018.34
D13-005 1,239.61
D13-006 1,313.36
D13-007 779.67
D13-008 1,116.68
D13-009 1,141.27
D13-010 1,313.36
D13-011 1,092.10
D13-012 1,239.61
D13-013 1,092.10
M13-003 167.70
M13-004 186.50
M13-005 177.10
M13-006 167.70
M13-007 177.10
M13-008 177.10
M13-009 124.25
M13-010 177.10
M13-011 167.70
M13-012 177.10
TOTAL: 3;68714—
1),/ o . i-
_
TRANSACTION LIST:
Type Method Description
Amount
Payment Credit C VISA 13,045.45
TOTAL: 13,045.45
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
000.322.100 6,849.15
City c TTukwilar
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: hap:/lvww ci.tukw ila.wa. us
STATE BUILDING SURCHARGE
640.237.114 45.00
TOTAL: 13,045.45
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION G
6300 Southcenter Blvd., #100, Tukwila. WA 98188 r_ (206) 431-3670
Permit Inspection Request Line (206) 431-2451
c3—ooh
Prot; ► Al 0C%
TYpeepi V Ar \IS U. t
Address!,.S.s
Date C II fd �!
6
r
(0(o (IAi
Special Instructions:
'''
Date Wanted 2
1 3
(a.m.
\!..,:..m
Requester:
Pron5lob ....... s( 0
09
(0
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
I
o
Inspects 04
Date
❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Jennifer Marshall
From:
Sent:
To:
Cc:
Subject:
Tim Fenlason <tfenlason@jonespayne.com>
Tuesday, January 08, 2013 11:29 AM
Jennifer Marshall
sharyn.parker@kingcounty.gov; Jesse Holgate
Re: KCIA RANRIP Submittal
You are correct. I'd like you to change the applications to reflect the amounts in the pink column. I thank you
for this extra work and if you'd like, I can gladly drive to your office to make the changes.
On Tue, Jan 8, 2013 at 9:56 AM, Jennifer Marshall <Jennifer.Marshall@tukwilawa.gov> wrote:
Good morning Tim,
Due to the fact that I cannot just arbitrarily change information on permit applications, I am clarifying the direction you
are giving me. Are you directing me to update the valuations provided on the applications submitted yesterday to the
numbers below under the column highlighted pink and labeled "Value Originally Provided?"
Applicant Name
Ochoa Residence
Nguyen Residence
Aragon Residence
Aragon Residence
Carter Residence
Christensen
Residence
Fasano Residence
Kerr Residence
Nguyen/Diem
Residence
Rivera Residence
Address
1186344Av
S
5016 Wallace
St
4610 S 124 St
12245 46 Av
S
1180240P1S
12212 48 Av
S
12029 44 Av
S
3834 S 116 St
11620 40 Av
S
11826 44 P1 S
Dev Permit Value Provided on
No Application
Value Originally
Provided
D13-004 $24,018.00 $26,622.00
D13-005 $31,135.00
D13-006 $32,099.00
D13-007 $17,201.00
D13-008 $25,472.00
D13-009 $28,169.00
D13-010 $37,403.00
D13-011 $23,133.00
D13-012 $33,129.00
D13-013 $23,619.00
$35,359.00
$38,407.00
$19,973.00
$30,978.00
$31,174.00
$38,918.00
$29,764.00
$35,722.00
$29,761.00
If these numbers are correct please respond accordingly and I place a copy of these emails in the file proving that I have
been authorized to make the changes. If they are not correct, please provide me with the correction valuations.
Thank you,
Jennifer Marshall
Permit Technician
Original Message
From: Tim Fenlason [mailto:tfenlason@jonespayne.coml
Sent: Monday, January 07, 2013 4:18 PM
1
To: Jennifer Marshall o •
Cc: sharyn.parker@kingcounty.gov; Bill Rambo; Jesse Holgate
Subject: Re: KCIA RANRIP Submittal
Jennifer,
My preference would be to use the amount provided to Bill and to update the applications. I know that the amounts
provided to Bill are correct, as I did those calculations myself.
On Mon, Jan 7, 2013 at 4:08 PM, Jennifer Marshall <Jennifer.Marshall@tukwilawa.gov> wrote:
> Good afternoon Tim,
> I received the applications and plans for ten lots for the above
> referenced project. I have completed the data entry in our permit
> system and discovered there are discrepancies with valuations provided
> to Bill Rambo and the valuations provided on the applications. I have
> attached a spreadsheet showing those discrepancies. The issue with
> there being a difference is that the permit estimate provided from
> Bill is no longer applicable.
> It is the end of my work day, so I will wrap this up tomorrow morning
> (I probably will not be able to fit it in until about 10 am) and
> provide the updated permit fees which will correspond with the new
> valuations given. At that point we will need payment to be made
> before the permits can begin the review process. I have also attached
> the original worksheet you and Bill were working with for your reference.
> Have a good evening.
> Jennifer Marshall
> Permit Technician, City of Tukwila
> T: 206 431-3670, F: 206 431-3665
> ]ennifer.marshall@tukwilawa.gov
Tim Fenlason Associate AIA
Senior Job Captain
2
*EMT COORS COP
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: D13-006
DATE: 01./07/12
PROJECT NAME: ARAGON RESIDENCE
SITE ADDRESS: 4610 S 124 ST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
Building Division
Public Works
fIVIQ 0 01' 10.
Fire Prevention 111
Structural
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete E]
Comments:
Incomplete ❑
DUE DATE: 01/10/13
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
TUESITHURS ROUTING:
Please Route Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 02/07/13
Approved ❑ Approved with Conditions k Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Contractors or Tradespeopi Printer Friendly Page
General/Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite/Apt.
City
State
Zip
County
Business Type
Parent Company
G & G SPECIALTY CONTRCTORS INC
4809214079
4633 S 36Th Street
Phoenix
AZ
85040
Out Of State
Corporation
G & G SPECIALTY CONTRCTORS INC
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
602975812
Active
GGSPEGS919RT
Construction Contractor
12/31/2009
12/31/2013
General
Unused
Business Owner Information
Name
Role
Effective Date
Expiration Date
GOODBALLET, CHARLES ELMER
Chief Executive Officer
12/28/2009
Bond Amount
WAVY, CHRISTINE
Chief Operating Officer
12/28/2009
59BSBEA9058
GOODBALLET, JAMES SCOTT
President
12/28/2009
GOODBALLET, TERESA LYNN
Secretary
12/28/2009
INS CO OF THE WEST
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
2
HARTFORD FIRE INS
CO
59BSBEA9058
12/18/2010
Until Cancelled
$12,000.00
01/03/2011
1
INS CO OF THE WEST
2278440
12/18/2009
Until Cancelled
$12,000.00
12/28/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
4
Companion
Property & Cas
Ins C
PCP10000270101
11/03/2012
11/03/2013
$1,000,000.00
11/16/2012
3
National Union
Fire Ins of PA
PCP1000027
11/03/2011
11/03/2012
$1,000,000.00
12/27/2011
2
LEXINGTON INS
CO
4392611702
12/31/2010
12/31/2011
$1,000,000.0001/11/2011
1
CO LEXINGTON INS
4392611701
12/31/2008
12/31/2010
$1,000,000.0001/14/2010
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
01/15/2013
KI
NG
CO U
N TY
INTERNATIONAL AIRPORT
RCRAFT NOIS.
E REMEDY IM
PROV.EMENTS PRO:Q:1RM
• SCORE. 'OF -WORK
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE
MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORIATION IN THE DRAWINGS AND
SPECIFICATIONS INCLUDING BUT NOT LIMITED TO:
APP
YES
LI: ABLE
NO
I. SELECTIVE REPLACEMENT OF EXISTING WINDOWS. WITH NEW VINYL -FRAMED ACOUSTICAL. WINDOWS.
X
2. CUT DOW OF UJINDOWS TO cotortx w1t14 EGRESS REQUIREMENTS.
X
3. INFILL OF EXISTING OPENINGS.
X
4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL ODORS.
X
5. INSTALLATION OF STORM DOORS.
6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS.
X
1. INSTALLATION OF SECONDARY SKYLIGHTS.
X
O. INSTALLATION OF PET DOORS.
X
9. INSTALLATION OF FIREPLACE FRESH AIR vENT.
X
10. IN4LLA.ION. OF CHIMNEY CAP.
X
11. REGULATED MATERIALS ABATEMENT.
X
12. ATTIC VENT BAFFLES.
13. INSTALLATION. OF Artic INSULATION.
X
4. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND
ASSOCIATED DUCTING.
X
15. INSTALLATION OF MECHANICAL. VENTILATION EQUIPMENT, FUR. ACE MODIFICATION AND
ASSOCIATED. DUCTING.
X
16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION.
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCHITECTURAL MODIFICATIONS.
X
18. INSTALLATION OF SMOKE DETECTORS.
X
I% NEW ELECTRICAL PANEL / SERVICE.
X
20.
KNO0:4NPIT.IDE
X
SEPARATE PERMIT
REQUIRED FOR:
leAsChankud
BrElectrical
grIblumbing
7as Piping
City of Tukwila
Et fi.r.IING DIVISION
Permit No.
Ei copy
049
-‘eini approval is subject to errors and omissions.
cif construction documents does not authorize
.
a y adopted code or ordinance. Receipt
is aclmowledged:
0 Al
Aw40046.- ANA
By
Date:
City Of lbkwlta
BUILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tulavila Building Division.
irT:: revisions will require a new plan submittal
C.ml may inciude additional plan review fees.
C00747Q12
BIP: PACKAGE .M-3,3
3-53-0058-044
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City -of Seattle, WA
APPLICABLE CODES:
2005 International Residential Code,
International Pim; Code,
International Mechanical Code
:�I1000.sss
ZONING: 5F1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION, TYPE:: ,(No: Change).
V B NON.SPRINKLEREP
LEGAL DESCRIPTION;
LOTS 21 AND 22, BLOCK 5, ALLENTOWN ADDITION. TO THE CITY OF SEATTLE, ACCORDING TO THE PLAT RESEARCH IN
VOLUME 12 OF PLATS, PAGE 100, IN KING COUNTY, WASHINGTON.
4,
•
' -
DRAWING INDEX
T0.0 TITLE, SHEET, PROJECT INFa
A1.0 FLOOR PLANS 4 NOTES
A2.0 WINDOW TypES, SCHEDULE 4 DETAILS -
A2.1 DOOR TYPES, SCHEDULE 4 DETAILS.
A22 MISCELLANEOUS DETAILS
423 WINDOW .FLASHING DETAILS
111.0 LEGENDS,SCHEDULES, ASEREV., GENERAL NOTES 4 DWG INDEX
112AND DETAILS
MECHANICAL
KAN E1; M5ELCWECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING 'COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph 206. 263. 9233
Fax 206, 296. 0190
Contact: Sharyn Parker
E-mail: SharynParttertokincjcounty.gov
ARCHITECT:
531 .5temper Architects P.L.LC.
4000 patricide Way SW, Suite 200
seogit..LUA 98100.
Ph: 206, 624:2111
Fax: 206. 0024. 297I3
Contact: Jerry Osborn, Melody Leung, -
Tim Fenla son,
E-mail: jerlasmstempercom
meloclyeamstenVetcoM
thtigenistemperooin
ACOUSTICAL ENG:NEER:
SM Acoustics
222 Etruria Strc*:Suite 100
Seattle WA 98109
Ph 206. 835. 0819
Fax: 206. 839. 0024
Contact; Mohamed Aft Allaoua
E-mail: mohamedessaacoustice.ccm
MECHANICAL ENGINEER:
The Greenlausch- Group
1900 West Nickerson St., Suite 201
Seattle, WA 58119
Ph 206 318 0569
Fax; 206. 31S. 0641
Contact: Dylan Turner
E-mail: DylanTfigreesnbusch.com
ELECTRICAL ENGINEER:
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253. 412. 3463
Contact: Brent Rollins
E -mall: bcretresuost.com
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 96102
Ph: 206. 232. 9639
Fax: 206. 162. 4180
Contact: Tim Ogden
E-mail: tim ogdenspbsenv.com
clgso SUPPORT SERVICES
The Jones Pane Group
123 North Washington St. 0200
!Boston, MA 02114
Contact: Tim Fenlason,
Cynthia Maeda
E-mail: crlaeolaojonespaynezom
REVIEWED FOR
STRUCTURAL ENGINEER:
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 58121
Ph 206. 622. 4580
Fax: 206. 622, 0422
Contact: Ron Martinson
ronm.psm-engineers.com
VICIN
ITY MAP (NTS)
CODE COMPLIANCE
APPROVED
JAN 1 1 2013
City of Tukwila
BUILDING DIVISION
RECEIVED
crry OF TUKWILA
I JAN ,0 7 20131
PERMIT CENTER
'' '' '' '' '''''' '' '''' •••
/•/'/'" „
...................... .......................
...........................
...........................
...........................
w•••••••••
.........
...,...... .„ .....„...
•
„ ".".....
............. ...............
. „ ........... ,........... „............... ................. .........,
........................
....,..., ................ „..„........... ..........
..............
•• •••••••"-
........„ .
• '
•
NORTH
S.M.STEMPER
ARCHITECTS
Professional Limited Liability Company
SUIQ°T0S20DOE'LSRETADTGTELE7IAVAY.. 987106
(208), 024 -?777. FAX (200 824-2o73
,sco.fr
: OF
0810.032224
<
JUNE 7, 2012
0
0
611
LU
ce
U -I
LU 0
z
LL
z
OD Ce°
0<
-1
U]
0
co
MPROVEMENTS
AIP NUMBER
355-00584044
z
0
›ai
-J
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
.JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
PROJECT
INFORMATION,
DRAWING
INDEX,
DIRECTORY
TO.0
0810.03.2224
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK of
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 500 FM TO &.00 AM EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT POOR OR WINDOW IS ON SITE. REMOvAL
AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 500 AM AND ':00 PM..
6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
1. ADD SOLID WOOD BLOCKING AT WINDOWS.
8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW. FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST ISE PROVIDED:.
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RECONSTRUCT'
SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE.
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS: PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL.
FOR TIMER LOCATION
18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS SHEET.
19. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 35" CLEAR IN FRONT OF CONTROL PANEL INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
2a MAXIMUM POUTER OUTAGE IS EIGHT HOURS. PO lLER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 PM.
PLAN KEYNOTES
ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW' SCHEDULE.
O DEMOLISH EXISTING DOOR(S), FRAME, CASING; TRIM AND THRESHOLD. INSTALL NEW EXTERIOR. DOOR, FRAME, CASING, TRIM, THRESHOLD AND
STORM DOOR REF. DOOR SCHEDULE.
OINSTALL NEW SECONDARY SLIDING DOOR(S). REF. DOOR SCHEDULE.
0 DEMOLISH EXISTING DOOR(S), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE. FLUSH SOLID CORE INTERIOR WOOD DOOR WITH TRIM
PACKAGE BOTH ELEVATIONS, INCLUDE INTERIOR HARDWARE SET.
REMOVE (E) FLOOR GRILL AND PATCH FLOOR WHERE GRILL WAS REMOVED TO ACCOMMODATE INSTALLATION OF: SECONDARY SLIDING
O GLASS DOOR. INSTALL FLOOR GRILL ADJACENT TO SECONDARY SLIDING GLASS DOOR. CAREFULLY REMOVE (E) FLOORING AS REQUIRED
TO ACCOMMODATE FLOOR GRILL INSTALLATION. DO NOT REMOVE (E) FLOORING EXCEPT UMAT IS NEEDED FOR INSTALLATION OF FLOOR
GRILL. COORD. DUCT WORK WITH MECH. DOCUMENTS.
OCOORDINATE FLOOR GRILL WITH MECHANICAL DOCUMENTS.
OINSTALL VENT BAFFLES) AT EXISTING ROOF VENT(S) IN ATTIC. REF. 3/422 FOR DETAIL.
O BLENDING UNIT LOCATED AND INSTALLED IN STORAGE ROOM, REF: MECI-. FOR UNIT,. REF, ELECT; FOR SPEED CONTROL AND DISCONNECT.
REF. 4/422 FOR DETAIL.
C..) INSTALL THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS.
10 INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL: AND ELECTRICAL DOCUMENT&.
II INSTALL NEW ELECTRICAL SERVICE AND NEW ELECTRICAL PANEL. COORDINATE WITH ELECTRICAL DOCUMENTS.
ODEMOLISH. EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422. FOR DETAIL. COORDINATE WITH
12 MECHANICAL DOCUMENTS.
ACCESS TO SITE. AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
LEGEND
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
Nil
ACOUSTICAL DOOR
REFER TO DOOR SCHEDULE
EXTERIOR STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH.: FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
1111111111111
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE
FEATHER TEXTURED CEILING OVER AT A
MIN. OF 24"FROM'EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
REF. MECH. 4 ELECT.
REF. GENERAL NOTE 11
ATTIC INSULATION
ATTIC INSULATION DAM
INSTALL BATTERY OPERATED SMOKE
DETECTORS
INSTALL BATTERY OPERATED SMOKE /
CARBON MONOXIDE DETECTORS
GAS METER
SOFFIT FOR MECHANICAL DUCTING.
SPECIAL NOTES:.
NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT, AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01 11 01 AND 02 82 00 FOR
REGULATED MATERIALS ABATEMENT..
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 11 01
AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PANT.
NOTE:
KNOB AND TUBE WIRING PRESENT.
�--
PRIOR TO COMMENCING WITH DEMOLITION
A "pre -demo inspection" is required.
Contractors shall provide documentation that
an "asbestos survey" has been completed. If
needed, abatement procedures per "Puget
Sound Clean Air Agency" shall be completed
and documentation of compliance shall be
provided at time of final inspection.
STORAGE
STORAGE
LOWER FLOOR PLAN
A. SOUTH ELEVATION.
B. WEST ELEVATION
C. NORTH ELEVATION
D. EAST ELEVATION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 1 1 2013
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TR D'WH
IJAN 0 7 2013
9EI MITCENE.F
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELIZID GE WAY SW
SUITE 200 • SEATTLE, IYA 98106
(206) 624-2777 • FAX (206) 624-2973
4220
t.r.... f.jy "RED
0810.032224
JUNE 7, 2012
c°
O
0
J
z
0
Z
ce
LU
F
z
z
0
U
z
MPROVEMENTS
D
W
ce
W
W
0
z
ce
AIP NUMBER
3-53-0058-044
Z
O
LtlicF -
z
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
NOTES
A1 .0
0810.03.2224
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.:
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8•.00 AM EACH
DAY. HOMEOWNERS WILL NAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS N THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE REMOVAL
AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8•.00 AM AND 5:00 PM..
6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
1 ADD SOLID WOOD BLOCKING AT WINDOWS.
8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT,
'3. EXISTING WINDOW COVERINGS MUST SE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
is INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK PAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT
SHELVING N COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTE1.41 WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND .CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
18 INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS SHEET.
IS CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE; SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. PORTER MUST SE PROVIDED AT RESIDENCE 8:00 AM. 4 AFTER 5:00 Pit
PLAN KEYNOTES
0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE.
DEMOLISH EXISTING DOOR(S), FRAME; CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND
�STORM DOOR. REF. DOOR SCHEDULE.
QINSTALL NEW SECONDARY SLIDING DOOR(S). REF. DOOR SCHEDULE.
0 DEMOLISH EXISTING DOOR(S), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE. FLUSH SOLID CORE INTERIOR WOOD DOOR WITH TRIM
PACKAGE BOTH ELEVATIONS, INCLUDE INTERIOR HARDWARE SET.
REMOVE (E) FLOOR GRILL AND PATCH FLOOR WHERE GRILL WAS REMOVED TO ACCOMMODATE INSTALLATION OF SECONDARY SLIDING
O GLASS DOOR INSTALL FLOOR GRILL ADJACENT TO SECONDARY SLIDING GLASS DOOR CAREFULLY REMOVE (E) FLOORING AS REQUIRED
TO ACCOMMODATE FLOOR GRILL INSTALLATION. DO NOT REMOVE (E) FLOORING EXCEPT WHAT IS NEEDED FOR INSTALLATION OF FLOOR
GRILL. COORD. DUCT WORK WITH MECH. DOCUMENTS.
0 COORDINATE FLOOR. GRILL WITH MECHANICAL DOCUMENTS.
( ) INSTALL VENT BAFFLES) AT EXISTING ROOF VENTS) IN ATTIC. REF. 31422 FOR DETAIL.
0BLENDING UNIT LOCATED' AND INSTALLED IN STORAGE ROOM, REF. MECH. FOR UNIT, REF, ELECT, FOR SPEED CONTROL AND DISCONNECT.
REF. 4/A22 FOR DETAIL.
() INSTALL THERMOSTAT: COORDINATE. WITH MECHANICAL DOCUMENTS.
10 INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL DOCUMENTS.
11 . INSTALL NEW ELECTRICAL SERVICE AND NEW ELECTRICAL PANEL. COORDINATE WITH ELECTRICAL DOCUMENTS.
DEMOLISH EXTERIOR WALL. ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A22 FOR DETAIL. COORDINATE WITH
C.) MECHANICAL DOCUMENTS.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
LEGEND
_Li„.,..,.,,,., ,,�,.y,.,,,,,»,.�,a,.,.LL.
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR
REFER TO DOOR SCHEDULE
EXTERIOR STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
„IIIII1111
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST SALE
FEATHER TEXTURED CEILING OVER AT' A
MIN. OF 24” FROM EDGE OF PATCHING..
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION. FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
REF..MECH.. t ELECT.
REF: GENERAL NOTE 11
F--- ATTIC INSULATION
ATTIC INSULATION DAM
SO INSTALL BATTERY OPERATED SMOKE
DETECTORS
SG INSTALL .BATTERY OPERATED SMOKE /
CARBON MONOXIDE DETECTORS
IGAS
GAS METER
SOFFIT FOR MECHANICAL DUCTING.
SPECIAL NOTES:
NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURE$. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01 11 01 AND 02 82 00 FOR
REGULATED MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. Itkl-kms TO SECTION 01 1101
AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT:
NOTE:
KNOB AND TUBE WIRING PRESENT.
r
B
CLOSET
18 x 18" EXIST.
ATTIC ACCESS
PANEL
LIVING
BOOTH
(E) FIRE PLACE
INSERT
J/
STORAGE
134TH
KITCHEN
1
CLOSET
BEP OOM
2
SITTING
BEDROOM
3
DINING
ROOM
0
0
1
•
(E) GRILL TO BE REMOVED
» m » » PATCH FLOOR OPENING
MAIN FLOOR PLAN
RUM
A. SOUTH ELEVATION
B. WEST ELEVATION
C. NORTH. ELEVATION
D. EAST ELEVATION
brva
REVIEWED FOR
CODE COMPLIANCEy�
APPROVE0
1 JAN 11 2013
City of Tukwila
BUILDING DIVISION
RECEIVEDECrilv or a rs
'JAN 0 7 2013
9A!
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, IYA 95106
(206) 624-2777 • FAX (206) 624-2973
:.»
1c£S E
Y tib
0810.03.2224
JUNE 7, 2012
F-
0
0
J
z
0
z
W
F-
z
z
0J
�✓
0
z
AIP NUMBER
3-53-0058-044
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
NOTES
A1.1
0810.03.2224
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WOW DAILY.
3. HOMEOWNER SHALL I4AVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO &00 All EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. DOORS OR WINDOWS SCHEDULED TO BE. REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE; REMOVAL
AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN &.00 AM AND 5:00 P1'1.
6. DO NOT INSTALL NEW DOORS OR WINDOWS WERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
1. ADD SOLID WOOD BLOCKING AT WINDOWS.
S. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT:
9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL, IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
II. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT`
SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENT& RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR, THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL 13E CONCEALED.
11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK. REFER TO ELECTRICAL
FOR TIMER LOCATION
16 INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET Al FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS SHEET.
19. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE; 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20, MAXIMUM POWER OUTAGE IS EIGHT HOURS. PC .ER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. t AFTER 5:00 :P1'1.
PLAN KEYNOTES
11) DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE.
O DEMOLISH EXISTING DOOR(S), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR FRAME, CASING, TRIM, THRESHOLD AND
STORM DOOR. REF. DOOR SCHEDULE.
0 INSTALL NEW SECONDARY SLIDING DOOR(S). REF. DOOR SCHEDULE.
G/';1 DEMOLISH EXISTING DOOR(S), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE. FLASH SOLID CORE INTERIOR WOOD' DOOR WITH TRIM
PACKAGE BOTH ELEVATIONS, INCLUDE INTERIOR HARDWARE SET:
REMOVE (E) FLOOR GRILL AND PATCH FLOOR WHERE GRILL WAS REMOVED TO ACCOMMODATE INSTALLATION OF SECONDARY SLIDING
0 GLASS DOOR. INSTALL FLOOR GRILL ADJACENT TO SECONDARY SLIDING GLASS DOOR. CAREFULLY REMOVE (E) FLOORING AS REQUIRED
TO ACCOMMODATE FLOOR GRILL INSTALLATION. DO NOT REMOVE (E) FLOORING EXCEPT WHAT IS NEEDED FOR INSTALLATION OF FLOOR
GRILL. COORD. DUCT WORK WITH MECH. DOCUMENTS.
0 COORDINATE FLOOR GRILL WITH MECHANICAL DOCUMENTS.
OINSTALL VENT BAFFLE(S) AT EXISTING ROOF VENT(S) IN ATTIC. REF. 3/A22 FOR DETAIL.
``J 0 BLENDING UNIT LOCATED AND INSTALLED IN STORAGE ROOM, REF: MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT.
REF. 4/422 FOR DETAIL.
0 INSTALL THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS,
i0 INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL. DOCUMENTS.
11 INSTALL NEW ELECTRICAL SERVICE AND NEW ELECTRICAL PANEL. COORDINATE WITH ELECTRICAL DOCUMENTS. 0 MECHANICAL DOCUMENTS.DEMOLISH EXTERIOR WALL. ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A1.2 FOR. DETAIL. COORDINATE WITH.
ACCESS TO SITE AND PARKING
I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
LEGEND
r r
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR
REFER TO DOOR SCHEDULE
EXTERIOR STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
1111111111111
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE
FEATHER TEXTURED CEILING OVER AT A
MIN. of 24" FROM EDGE OF PATCHING.
'; MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
y ,
REF,_ MECH., 4 ELECT.
REF. GENERAL NOTE 11
r----- ATTIC INSULATION
ATTIC INSULATION DAM
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
CD
INSTALL BATTERY OPERATED SMOKE /
CARBON MONOXIDE DETECTORS
GAS METER.
SOFFIT FOR MECHANICAL DUCTING
SPECIAL NOTES:.
NOTES:
I. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01 11 01 AND 02 82 00 FOR
REGULATED MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01' II 01
AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT:
NOTE:
KNOB AND TUBE WIRING PRESENT.
1"1'-2"
TI•%'
I.I. -
1'1
1I
r
❑6
FOYER
BATH
2
11
•
•
I"
-A-
•
..—: �� I .1 1
I /
.16"„x 14.«-
1(01
ATTIC ACCESS
PANEL
•
. . . .. �( .
.
•
•
•
. . . . . ; .1 . _
•
GS
•
•
•
•
STUDY
KITCHEN
2
..........
4.1-1
.J'�
• rIlk • AA At
•
I0'_2"
•
'_6"
TVP.
•
14'-3"
16'—IPS
J
ATTIC/ UPPER FLOOR PLAN
114"=1'-0"
A. SOUTH ELEVATION
B. WEST ELEVATION
C. NORTH ELEVATION
D. EAST ELEVATION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 11 2013
•
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TU$(WI(A
JAN 0 7 2013
PERMIT CENTEF
!%/
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
ra (1 I: s w.
0810.03.2224
JUNE 7, 2012
F-
0
0_
aC
J
z
0
z
F -
z
z
0
U
C
z
AIP NUMBER
MPROVEMENTS
3-53-0058-044
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
NOTES
A1 .2
0810.03.2224
WINDOW TYPES
L 2.
HORIZONTAL DOUBLE HUNG
XX -SLIDER
4.
FIXED SLIDER/ FIXED/ SLIDER
5.
CASEMENT
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
TYPE
SIZE
W x H
TRIM FINISH
INT../ EXT.
REMARKS
DETAIL
SET
LIVING ROOM
4
1-5u x
STAIN/STAIN.
SAFETY GLAZING REQUIRED, REMOVE 4 REINSTALL SHUTTERS
1/421).
B
LIVINGROOM
31-10" x 31.10"
STAIN/STAN
REMOVE 4 REINSTALL. WINDOW SHUTTERS
2/42.0
C
LIVING Roar]
31-10H x 31-10"
STAIN/STAN
REMOVE -4IREINSTALL WiNpap.SHUTTERS
•2/A2 0
BEDROOM:1
4'*0! 2'4"
etTAIN./STAiN.
REMOVE 4 REINSTALL WINDOW SHUTTERS
1/4.0
E
BEDROOM I
2C10"
STAIN/STAIN
SAFETY GLAZING REQUIRED
I/A20
F
KITCHEN
2
7.60 x 314"
STAIN/STAIN
G
KITCHEN
2
x.: 31.70"
ISTAIN/STAIN
3140
1.4
KITCHEN
4'4" x
sTAN/STAN.
1/A20
J
•BEDROOM 2
SITTING ROOM
41-0" x 2"--4"
41-5" X 3" -Ir
STAN/STAN
S, AN/STAIN
SAFETY GLAZING REQUIRED
2/42.0
I/A2.o
K
BEDROOM .3
2LS" Ix 4C2U-
STAN/STAIN
1/A2.0
L
M
BEDROOM
IsEDRocts1 3
3'-'1011 V.I0"
STAIN/STAN -
STAN/STAIN
.1/40
N.
BEDROOM 3
X 1.1.:100
STAN/STAIN
.11A20
BEDROOM 3
31-10u x 1,-10u
STAIN/STAIN
1/42.0
BEDROOM 3
3
2'.10" x P-10"
STAIN/STAN
1/A21)
BEDROOM 4.
3"-10" x
STAN/STAN
SAFET GLAZING REQUIRED
I/A2o
R
KITCHEN
4'40" :x 2'40".
STAN/STAIN
SAFETY GLAZING REQUIRED
1/440
TYPICAL WIN
DOW SCHEDULE NOTES
1, NQTE.c WHERE SAFETY LAZING.GIS INDICATED, BUT NOT
SCHEDULED IN .SECTION QS 00'00,'Al4„1J.NLAMINATED: GLAZING
PANELS:, IN THAT UNIT ARE TO BE TEMPERED. i;,-Am.INATED:oLAZtNQ
PANELS NEED, NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS. SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND. WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO ;START' OF
WORK.
4, FOR HEAD:- FLASHING INSTALLATION REFER TO HEAD .:FLASHINIQ,
DETAIL:WON WINDOW TYPES, SCHEDULE & DETAILS SHEET,
1
HEMMED EDGE I I END CLOSURE
A HEAD FLASHING
" 3" 1' - 0"
DETAIL TYP.
(E) BACKER BOARD
LE) VINYL SIDING
UNDETERMINED VINYL SIDING SUBSTRATE
cARERILLY LIFT CE) wALL,,UNPERLAYMENT
:AND INSTALL TOP EDGE Of SEI.„F :ADHERING
MEMBRANE AGAINST SHEAVING. LAP OVER
METAL FLASHING. AND EXTEND SELF
ADHERING ,FLASHING 4" UP WALL FROM TOP
FLASHING. LAP CE) WALL UNDERLAYMENT
OVER 'TOP OF SELF ADHERING FLASHING
REMOVE (E)VINYL SIDING AS REqp
FOR INSTALLATION EOF WIN -pow
LASHINa REPLACE/ RE -INSTALL
SIDING 4, ACCESSORIES TO MATCH .
VINYL J C144NEL TRIM
PRE..PRIMED, GALV SHEET METAL
PLASHING UNDER SELF -ADHERING
MEMBRANE. COLOR. TO BE SELECTED IN
THE FIELD
CE) EXTERIOR SHEATHING
CE) WALL UNPERLAYMENT
SELF ADHERING MEMBRANE
TOUCH UP PAINT, AS REQID
ACOUSTICAL WINDOW ASSEMBLY.
CE) BACKER BOARD
(E) BUILDING PAPER
UNDETERMINED VINYL. sIDING„..sUBSTRATE:
WIN
DOW HEAD
..
CONTINUOUS SEALANT, TYR
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP UP BATT
INSULATION
SEALANT •4 BACKER ROD
CAREFULLY REMOVE CE) VINYL:
'MEMBRANE. INSTALL: SOLID
INSTALLATION:OF SELF ADHERING,
SIDING. CUT 1sApc:fp. BACKER:
BOARD AND ,(5) AMYL roR:
ISLOCKIN4 TO PROVIDE NAILING
fOR.BACKER.BOARD„ RE- INSTALL
REPLACEMENT BACKER:BOARD
(E) VINYL :SPINS:
(E) EXTERIOR 'SHEATHING
TOUCH UP PAINT, AS REM?
CONTINUOUS SEALANT, TYP.
CE)au5
BACKER ROD 4 SEALANT
SOLID WOOD TRIM
JAMBLINING. FINISH TO
MATCH (E)
BACKER ROD SEALANT
ACOUSTICAL WINDOW ASSEMBLY
SELF -ADHERING MEMBRANE
ACOUSTICAL WINDOW ASSEMBLY.
SEALANT 4 BACKER Rol)
VINYL J CHANNEL TRIM
WINDOWJAMa..
SHIM AS NECESSARY
FILL GAP WI BATT
INSULATION
SEALANT 4 BACKER ROD
14,":
3/4" WOOD SILL
SOLID WOOD TRIM
•SELF -ADHERING MEMBRANE
LAP OVER (E) WALL
UNDERLAYMENT 41I.
CONTNUOUS SEALANT, TYP.
TOUCH UP PANT, AS REQ'D
UNDETERMINED VINYL. SIDING SUBSTRATE
CAREFULLY REMOVE TOP COURSES OF (E)
VINYL SIDING AND BACKER BOARD FOR
NOTALI_ATIc7N OP WINDOW ASSEMBLY 4
TRIM. REPLACE/ RE -INSTALL SIDING TO
MATCH CE)
•(E) BACKER BOARD
(E) VINYL SIDING
VINYL SID
37-1,-
WIN
DOW SILL
ING - WI
NDOW DETAIL SET
CE) ate
CE) BACKER BOARD
(E) VINYL SIDING
UNDETERMINED VINYL SIDSUBSTRATE
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP OVER
METAL FLASHING AND EXTEND SELF
ADHERING FLASHING 4" UP WALL FROM TOP
Of FLASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF SELF ADHERING PLASHING
REMOVE (E) VINYL sIDNG AS REO'D
FOR INSTALLATION OF WINDOW 4
FLASHING. REPLACE/ RE -INSTALL
SIDING 4 ACCESSORIES TO MATCH (E),
(E) EXTERIOR SHEATHING
VINYL J CHANNEL TRIM
PRE -FIRMED, GALV SHEET METAL.
FLASHING UNDER SELF -ADHERING
MEMBRANE. COLoR TO EsE SELECTED IN
THE FIELD
ACOUSTICAL WINDOW ASSEMBLY.
CE) BACKER BOARD
r""*••••-....
CE) WALL UNDERLAMENT
(E) WD. PANELING
SELF ADHERING MEMBRANE
CONTINUOUS SEALANT,
TYP.
SOLID WOOD TRIM
UNDETERMINED VINYL SIDING SUBSTRATE
VINYL CHANNEL TRIM.
BACKER ROD 4 SEALANT.
ACOUSTICAL WINDOW ASSEMBLY
SELF -ADHERING MEMBRANE
WINDOW HEAD
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
SEALANT 4 BACKER Rot..
•CAREFULLY REMOVE CE) VINYL
SIDING. CUT BACKCE) BACKER
BOARD AND(E) VINYL SIDING FOR.
INSTALLATION OF SELF ADHERING
MEMBRANE. INSTALL SOLID p.T.
•I3LOCXING To. PROVIDE NAILING
FOR BACKER BOAV. RE- INSTALL
REPLACEMENT BACKER BOARD 4
(e) VINYL Sit NS
CE) UP. PANELING
CONTINUOUS SEALANT, TYR
SOLID WOOP TRIM
ACOUSTICAL WINDOW. ASSEMBLY.
SEALANT 4 SACKER ROD
VINYL J CHANNEL TRIM
WINDOW JAMB
UNDETERMINED VINYL SIDING SUBSTRATE
CAREFULLY REMOVE TOP COURSES OF CE).
VINYL SIDING AND SACKER BOARD FOR
INSTALLATION OF WINDOW ASSEMBLY 4
TRIM. REPLACE/ RE -INSTALL SIDING TO
MATCH (E)
CE) BACKER BOARD
CE) VINYL SIDING
VINYL SI
311.= 11 - 0"
WP JAMB LINING
SEALANT
SWIM AS NECESSARY
FILL GAP WI BATT
INSULATION
/4"
BACKER ROD 4
SEALANT
3/4" WOOD SILL
SOLID WOOD TRIM
WINDOW SILL
DING -WIN
A
DOW DETAIL SET
CONTINUOUS
SEALANT, TYP.
SELF -ADHERING
MEMBRANE
CE) WD. PANELING
CE) BACKER BOARD
(E) vNYL SIDING
UNDETERMINED VINYL SIDING SUBSTRATE
CAREFULLY LIFT CE) WALL UNDERLAYMENT
AND INSTALL TOP EDGE. OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP OVER
METAL FLASHING AND EXTEND SELF
ADHERING FLASHING 4" UP WALL PROM TOP
OF FLASHING. LAP CE) WALL UNDERLAYMENT
OVER TOP OF SELF ADHERING FLASHING
REMOVE CE) VINYL SIDING AS REM"
FOR INSTALLATION. OF WINDOW 4
FLASHING. REPLACE/ RE -INSTALL
SIDING 4 ACCESWRIES TO MATCH (E).
VINYL J CHANNEL TRIM
PRE -PRIMED, GALV SHEET METAL
FLASHING UNDER SELF -ADHERING
MEMBRANE, COLOR 10 BE SELECTED IN
THE FIELD
ACOUSTICAL WINDOW ASSEMBLY.
(E) BACKER BOARD
CE) EXTERIOR SHEATHING
.(E) WALL UNDERLAYMENT
CE) WD. PANELING
SELF ADHERING MEMBRANE
UNDETERMINED VINYL SIDING SUBSTRATE
VINYL J CHANNEL TRIM
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
SELF -ADHERING MEMBRANE
ACOUSTICAL WINDOW ASSEMBLY.
SEALANT 4 SACKER ROD
VINYL J CHANNEL TRIM
II I
WINDOW' HEAD
CONTINUOUS SEALANT,
TYP.
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP WI BATT
INSULATION
SEALANT *SACKER ROD
CAREFULLY REMOVE (E) VINYL
SIDING. OUT •134cK ,(E) BACKER
BOARD AND CE) VINYL SIDING FOR
INSTALLATION OF .SELF ADHERING
MEMBRANE. INSTALL SOLID PT.
ELooKING. TO PROVIDE NAILING.
FOR SACKER BOARD. lit- INSTALL
REPLACEMENT BACKER BOARD 4
CE) VINYL SIDING
(E) -W17. PANELING
WINDOW JAMB
CONTINUOUS SEALANT, TYp.
SOLIDWOOD TRIM
LID JAMB LINING
SEALANT
SHIM ASNECESSARY
FILL GAP W/ BATT
INSULATION
UNDETERMINED VINYL SIDING SUBSTRATE
CAREFULLY REMOYE TOP COURSES OF (E)
VINYL SIDING AND BACKER BOARD FOR
INSTALLATION OF WINDOW ASSEMBLY 4
TRIM. REPLACE/ RE -INSTALL SIDING TO
MATCH (E)
(E) SACKER BOARD
CE) VINYL SIDING
BACKER RoD 4
SEALANT
3/4" WOOD SILL.
In" ROUND WD. TRIM
CONTINUOUS SEALANT, TYP.
(E) WD. JAMB LINING
SELF -ADHERING
MEMBRANE
CE) TILE
(E)GW13
WINDOW SILL (3 00
VINYL SIDING - WINDOW DETAIL SET
3" = II - 0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 1 1 2013
•
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF rwwitA
1JAN i0 7 2013
PERMIT CENTER
S.MSTEMPER
ARCHITECTS
A Professional -Limited Liability Company
4000 DELRIDGF WAY SW
SUITE 200 * SEATTLE, WA 98106
(20.5) 624-2777 • FAX (206) 624-2973
01.:MPTER •
STATE
0810.03.2224
JUNE 7, 2012
0
Ct
0
UJ
F—
z
0
0
MPROVEMENTS
>-
0
LU
2
Lu
LU
ce
0
ILL1
C7)
1.1.1
AIP NUMBER
3-53-0058-044
0
0
z
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.2224
DOOM TYPES
FLUSH SCW
W/ WAGON WHEEL
AND 4 PANELS
LW SAFETY GLAZING..
W/ OBSERVATION PORT
FLUSH 50111
1 LITE
LW 2 PANELS
IRI/ SAFETY GLAZING.
G
SECONDARY SLIDING
GLASS POOR
LW SAFETY GLAZING
EXTERIOR
SINGLE LEAF STOW
lU/
SAFETY GLAZING
DOOR SCHEDULE
r;.
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
WxH
FINISH
INT./ EXT.
HARDWARE
ARE
SET / FINISH
KNOB / LEVER
SE T
LOCK
SET
DETAIL
SET
LIVING ROOM
A
2'4"
STAN/ STAIN
HW -1 f 603
DK -4
LOCK -1
1/A2:0
2
KITCHEN (INTERIOR?`.
B
2`-S" x ,6"-4"
STAIN/ STAIN
I4-2 / 603
DK -2
LOCK -2
2/A2.0
3
KITCHEN
5'_1I'r x
STAIN/ STAIN
3/A2:0
TYPICAL DOOR SCH
EDULE NOTES
1. WHERE SAFETY GLAZING IS INDICATED, BUT: NOT SCHEDULED IN
SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE To BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT. SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2
SLIDING. GLASS DOORS SHALL MATCH THE OPERATION. OF THE.
EXISTING SLIDING GLASS DOORS THEY REPLACE OR. COVER,.
3 FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS
AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH. HOMEOWNER PRIOR TO START OF WORK.
5 FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET.
HEAD FLASH
3 1' - (}"
LNG DETAIL TYP,
(E) BACKER BOARD
(E) VINYL SIDING
CAREFULLY LIFT (E) WALL UNDERL4TMENT'
AND INSTALL, TOP EIDE OF SELF ADHERING
FLASHING AGAINST SHEATHING. LAP OVER
METAL FLASHING AND EXTEND SELF
ADHERING FLASHING 4" UP WALL FROM TOP
OF FLASHING.. LAP (E) WALL UNDERI.AYMENT
OVER TOP OF SELF ADHERING FLASHING:.
UNDETERMINED v'INYL
SIDING SUBSTRATE
(E) WALL UNPERLAYMENT
SELF ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
REMOVE (E) VINYL SID NG AS Kap
FOR INSTALLATION OF WINDOW 4 -:
FLASHING. REPLACE/ REINSTALL
SIDING 4 ACCESSORIES To MATCH (E)
VINYL J CHANNEL TRIM
PRE -PRIMED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
SE SELECTED N THE FIELD
CONTINUOUS SEALANT 3EHINP Z BAR
FRAME
STORM. DOOR PER SCHEDULE
2" MIN.
(E) BACKER BOARD
(E) VINYL SIDING
TOUCH UP FAINT,
AS IR1=Q'D
CONTINUOUS
SEALANT, TYP.
SOLID IMOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION.
WOOD FRAME:
KEW AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING.
DOOR PER SCHEDULE`
DOOR
HEAD
CAREFULLY LIFT CE) WALL UNDERLA'iMENT:. _.
AND NSTALL:TOP EDGE OF SELF ADHERING
FLASHING AGAINST SHEATHING LAP•OVER
METAL'FLASHNO AN. EXTEND iiSELF
ADHERING FLASHING 4" UP WALL FROM TOP
OF FLASHING. LAP (E)< WALL UNDERLAVIENT'
OVER. TOP OF SELF ADHERING FLASHING:
REMOVE (E) VINYL SIDING AS REQ'D
FOR. INSTALLATION a WINDOW t:
FLASHING. REPLACE/ RE -INSTALL
SIDING. 4 ACCESSORIES TO MATCH (E)
VINYL J CHANNEL TRIM
CONTINUOUS SEALANT BEHIND Z BAR:
FRAME
(E) EXTERIOR
SHEATHING
SELF ADHERING MEMBRANE
TOUCH UP PAINT, AS REQ'0
CONTINUOUS SEALANT, TYP.
SOLID WOOD TRIM
SWIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KEW AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
EATHERSTRIPPING
DOOR PER SCHEDULE.
DOOR JA
MB
HARDWOOD JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2": MIN.
DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR. STRUCTURE
VINYL SI
,,.
DING
DOOR SILL.
DOOR
DETAIL SET
SHIM AS NECESSARY
FILL GAP W/ .BATT
INSULATION
BACKER ROD AND SEALANT
SOLID WOAD TRIM
WOOD FRAME
SURFACE APPLIED
CONTINUOUS WEATHER
STRIPPING
KEIF IN CONTINUOUS
WEATHER STRIPPING
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD AND SEALANT
SOLID WOOD TRIM
WOOD FRAME
SURFACE APPLIED
CONTINUOUS WEATHER
STRIPPING
KEIRF IN CONTINUOUS
WEATHER STRIPPING
JAMB BEYOND
Wo D DOOR
PER SCHEDULE
DOOR SHOE'
AUTOMATIC DOOR SWEEP
DOOR HEAD
TOUCH UP PAINT,;
AS •REQ'P
CONTINUOUS
SEALANT, TTP:.
SOLID WOOD TRIM
INTERIOR DOOR PER
SCHEDULE
• EXISTING FRAMING
TOUCH UP PAINT, :AS REQ'D
CONTINUOUS
SEALANT, TTP.
SOLID• Wc)OD TRIM
1
DOOR JAMB
DOOR PER SCHEDULE
DOOR SILL
(E) EXTERIOR SHEATHING
CONTINUOUS SEALANT
2X TAPERED CAP
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS Zx SOLID BLOCKING
AROUND PERIMETER: OF DOOR FRAME.
PAINT ALL EXPOSED EDGES TO MATCH
(E) TRIM
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG"R
INSTRUCTIONS
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING AROUND
PERIMETER OF POOR FRAME. PAINT ALL
EXPOSED EDGES TO MATCH (E) TRIM
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
DOO
R HEAD
SOLID WOOD LINING
(E) SLIDING GLASS DOOR
DOOR JAMB
SOLID WOOD LINING
(E.) SLIDING GLASS DOOR
b3O
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL- PER MFG'R
INSTRUCTIONS:
(E) SLIDING GLASS POOR
(E) CONC. SLAB. OR (E) WD..
FLOOR FRAMING
DOOR SIL
L
INTERIOR - SLIDING GLASS DOOR DETAIL SET
3" = 1' - 0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 11 2013
City of Tukwila
BUILDING DIVISION
RECEIVED
oPrimmILA
JAN 0 7 2013
S.M.STEMPER
ARCHITECTS
A Professional Limited' Liability. Company
4000 DDLEIDGE WAY SW
SUITE 20.0 • SEATTLE, 11'A 98106
(206) 624-2777 • FAX (206) 624-2973
0810.03.2224
JUNE 7, 2.012
0
0
J z
Q ui 0
O 0
H z
Z W C/)
Ci COc
W
LL
0 Ce
C
W
MPROVEMENTS
AIP NUMBER
3-53-0058-044
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.2224
(E) SACKER BOARD
(E) VINYL SIDING
CAREFULLY LIFT (E) WALL UNPERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TIP AT I -15.4D AND JAMBS.
REMOVE (E) VINYL SIDING FOR
INSTALLATION OF VENT FIXTURE AND
FLASHING. REPLACE OR RE INSTALL
SIDING AS REQ'D TO MATCH (E).SIDING.
PRE -PRIMED, GALY SHEET METAL
FLASHING (11/ F.F. END CAPS UNDER
SURFACE MOUNTED REGLET AND CAP
FLASHING. PAINT COLOR TO BE
SELECTED IN THE FIELD
SHIM BACKER BOARD AS
REQUIRED
(E) WALL UNDERLAYMENT
SELF. AOHERINa, BITUMINOUS,
MEMBRANE FLASHING
(E) :EXTERIOR. SHEATHING'
PAINT VENTILATION FIxTURE,
COLOR TO BE SELECTED IN
THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PAINT INTERIOR kW
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
2X BLOCKING
2X2 SLOCKNG, 4 SIDES
(P.T)
REPLACEMENT SIDING AS REQUIRED
UNDETERMINED VINYL SIDING SUBSTRATE
EXISTING ROOF VENT
EXISTING ROOF
STRUCTURE
2X BLOCKING
AIR INTAKE DETAIL AT EXTERIOR
311 = 1' - 0"
EXIST NG VENT COVER
• I%
CROSS SECTION
EXISTING ROOF
STRUCTURE
NEW 2"X SPACER AS
REQUIRED TO PROVIDE
6" CLEAR AIR SPACE
NEW 21X SPACER
LATERAL SECTION
II •
MN. TYPICAL 'TOP 4,
15OrrOM,'
NEW I". INSULATION !a0ARD.,
GLUM" TO NEW 3/4"
EXTERIOR GRADE.
PLYWOOD.
ROOF VENT BAFFLE DETIAL
1 1/2" = II _0I1
EXISTING ROOF
(E) ROOF FRAMING
(E) EAvE VENT
151.011N N CELLULOSE
INSULATION WITH A coMSINE
VALUE OF NOT LESS THAN
R-38
INSULATION DAM
2 INSULATION DAM DETAIL
(E) WALL FRAMING
FILING MOUNTING BRACI<ET
1411 X IV ANGLE IRON LEG BOLTED
TO (E) STRUCTURE
BLENDING AIR UNIT DETAIL
1 1/2" = 1' -.0"
cEILING
4"MN
ACCEPTABLE
I4ERE
NOTE: REMOVE EXISTING SMOKE
DETECTORS, CUT AND PATCH CEILING AS
REQUIRED: REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND
TEXTURE AND PAINT TO FILL ALL. HOLES
LEFT FROM EXISTING CONDITION. PAINT
TO MATCH SURROUNDING CONDITIONS.
SMO
I
SIOE WALL
SUSPEND MECI4 UNIT FROM (E)
.STR4CTURE .RE:. MECHANICAL
MECH UNIT ANp, DUCTS -
REF MECHANICAL
r3--%‘00(9
KE DE ECTOR INSTALLATION DETAIL
3" = 1' - 0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 11 witi
•
City of Tukwila
BUILDING DIVISION
FECENICI
env (Ir wv ore
1JAN 0.7 2441
S.MSTEMPER
ARCHITECTS
A Profesaional Limited Liability Company
4000 DELRIDGE WAY $W
SUITE 200 SEATTLE, WA 98106
(208) 624-2777 • FAX (206) 624-2973
•
V
0810.03.2224
JUNE 7, 2012
0
cLz'17C-I
F-
0 0
I— Z
Z CO
LLQ 0
Z <
zG
C.)
0<o
0
L1.1
0
MPROVEMENTS
AIP NUMBER
3-53-0058-044
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML,&TF
DRAWN
LB&CP
MISC.
DETAILS
A2.2
0810.03.2224
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND HEAD
NOTE: REMOVE (E) SIDING BACK FIRCrt (E) RQ. AS MOD
CE) SIDING NOT SHOLLN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLI-NG
14A5 DEEN INSTALLED
LAP SILL MEMBRANE
FLASHING 2-1/2"
OVER (E) DLDG.
PAPER AT SILL.
EXTEND I i" BEYOND
R.O. AT EA. END OF
SILL.
614EATI4ING
CUT SILL
FLASHING 4 FOLD
THROUGH RO. AS
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
614EATHING
MIN
El
MEMBRA
NE FLASHING. AT SILL
BUTTERFLY CORNER FLASHING
SCALE:
LIFT (E) MPG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
CE) SIDING NOT
SHOWN FOR CLARITY.
NTS
NOTE: REMOVE (E) SIDING SACK FROM (E) 'IRO. AS REQD
(E) SIDING NOT SHOWN FOR CLARITY'. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAP
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE.
EXCESS MATERIAL.
po NOT SEAL FLANGE
AT WINDOW SILL
(E) DLDG. PAPER
AT SILL.
• ''';'ZT
N•
\\\
ELEVATION. VIEW
NOTE: jNsTALL, LONpow.:FER1IFONO:.5PgalF10ATIO
NOTIFY TacH1410,44. mm00417,4;14. OF DISCREPANCIES
WINDOW MEMB
RANE
NSTALLATION
MEMBR4NE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENNGS.
SEND
ANCHORAGE
NAILS D01114
;>. OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
REMOVED
SCALE:
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY,
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
ft
S
NOTE: REMOVE (E) SIDING DAM FROM (E) RO. AS REQ'D
CE) SIDING NOT 51401.1.N FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMDRANE FLASHING
HAS BEEN INSTALLED.
r --
WHERE REQUIRED, TRIM
(E) ISLOG PAPER. AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW. TRIM
(FOLLOWING STEPS).
HEAD FLASHING PREPARATION
SCALE: NTS
NOTE: REMOVE CE) SIDING SACK FROM (E) RO: AS. REO'D
(E) SIDING NOT 51401114 FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
MEMBI3AN
CUT JAMB FLASHING 4
FOLD AROUND WINDOW.
OPENING AS. SHOIN.
EXTEND i-vr BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
E FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS. RE0P
(a) SIDING NOT 51401114 FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
INSTALL 614T. METAL.
HEAD FLASHING
LINDER (E) BLDG
PAPER.
- INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASI4ING.
MEMBRANE FLASH)
NG AT JAMB
SCALE: NTS.
NOTE: REMOVE (E) 'SIDING SACK FROM (E) R.O. AS REceo
(E) SIDING NOT 514004 FOR CLARITY REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLAS1-ING
HAS BEEN INSTALLED. ALLOW VS" l CLEARANCE:
SETWEEN FILA514NG AND
BOtIEDGE OF (E)
SIDING.
(E)
SHOW
DIAGRAMATICALLY.
(E) SIDING NOT
514011.14 FOR
CLARITY.
HEAD
F
LASHING INSTALLATION
SCALE:
NTS
CE) BLDG. 'PAPER
MEMBRANE FLASH
ING AT HEAD
CUT HEAD
FLASHING. 4 FOLD
AROUND WINDOW
OPENING AS
514011N. EXTEND
1-1a1 BEYOND
RQ. AT NEAP
AND JANOS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
SCALE:. NTS,
NOTE: REMOVE (E) SIDING BACK FROM (E) W. AS REoP
(E) SIDING NOT 514011.14 FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FI-ASHING
HAS BEEN INSTALLED.
INSTALL HEAD
FLANGE FLASHING.
OVER WINDOW
NAILING FLANGE
AND. FLASHING.
I: 6:
\.s..L.,) SCALE: N
0
WINDOW FLASHING
J I
INSTALLATION
TS
SHEET METAL HEAD
FLASHING
(E) STAN*
WOOD T
RIM INSTALLATION
SCALE: NTS
(E) EILDG. PAPER
BENEATH spit,*
INSTALL U. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDNG. APPLY
SEALANT DEAD TO
JOINT BETWEEN WINDOW
•IM AND SIDING.
LEAVE... 1/4"-3,18" GAP
BETWEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
1: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS
"SELF AP44EARING: MEN :.RANE FLASHING" TYPICALLY
REPERtr) TO AS "PEEL AND STICK'
2: DETAILS "L 2, AND 30 REFER TO MEME3RONE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3; DETAILS "5 AND 6" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS SEEN SET IN PLACE,
SHIMMED, AND ANCI4ORED.
4: DETAILS "1 AND 5" •REFER TO SHEET METAL HEAD
FLASHING.
5: DETAIL REFERS TO WOOD TRIM AND CAULK
JOINTS.
(3 0
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 1 1 7fin
City of Tukwila
BUILDING DIVISION
RECEIVED
cm, OF T1, lin4M,A
JAN 0 7 2013
PERmiT Cergie.#
S.MSTEMPER
ARCHITECTS
A Ptofeasional Limited Liability Company
4000 DELRIDG WAY SW
•SUITE 200 SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
11J
. . .
JUNE 7, 2012
0810.03.2224
0
CL.
Ce
0
z
LU
z
z
0
0
0
AIR NUMBER
MPROVEMENTS
3-53-0058-044
0
0
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
FLASHING
DE -TAILS
A2.3
0810.03.2224
AlaBREVIA. .1QN$
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTU H
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
M TG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
00
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
SRC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
WB
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING. UNIT
ABOVE FINISHED: CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR. -CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL: UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PERMINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN:
DRAWING
EXISTING
EACH, EXHAUST AIR
.ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL -STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE.
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY'
INCH
KILOWATT,: (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE.
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTEC11ON' ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
pOimps. PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE:: ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING,
STATIC PRESSURE
STATIC PRESSURE DROP'
SPECIFICATIONS
SEATTLE RESIDENTIAL CODE
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT,. VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LI
STED
SYMBO
ABBR
OR XX
0
X/Y
////,
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF
FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO -BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GEN
M2.0 MECHANICAL FLOOR PLANS
E.RAL NOTES AND DRAWING INDEX
MZ1 MECHANICAL FLOOR PLANS AND DETAILS
GENERAL NIQTES
1. THg MECHANICAL iSYSTEM sHALL CONSIST of ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANSDIAGRAMS, DETAILS, ETC., AND ALL WORK As IDENTIFIED IN THE: .Bp-pliFtc•ATIpNB..: WORK
INCLUDES FURNISHING, INSTALLING .SYSTEM INTEGRATION TEsTiNc,TRAINING AND WARRANTY OF THE. ;MECHANICAL SYSTEMS As SHOWN AND SPECIFIED. pRovipF. A: COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM ',OPERATION.
2, THE DESIGN OF MECHANICAL SYSTEMS HA, ; BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED-' BY THE MANUFACTURERS. LISTED ON THE EQUIPMENT SCHEDULE, EQUIPMENT NAMED IN THE SPECIFICATIONS.
MAY BE :SUBSTITUTED PROVIDED THAT. THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND. HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES .AND GUARANTEE IN :WRITING THAT NO ADDITIONAL -COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION,
3,_CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS 'BEFORE 'BEGINNING coNsTRucTioN OR oRDERNG 'EQUIPMENT, ' DO NOT scALE. FROM PLANS..
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9
REQUI
REMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
5. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 41-0" AFF. UNLESS NOTED OTHERWISE
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 10t-0' CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAM
NG, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 31-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
SYMBOL
XXX
ABBR
DIN I +
et -1-
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
*lh VD
RA/EA
loio OR
EQUIP
NG -
a
1.
RG
SA
SA
RA/EA
SD
FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDE/:LL
SUPPLY AIR DUCT
RETURN. MR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT .LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUI
REMENT
MECHANICAL
ELECTRICAL COORD
NATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
DESCRIPTION
VOLTS
PH
FURN SHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
23
26
„ .23. ...
26
NfI
23
26
N/A
REMARKS
:BVI
BLENDING UNIT VENTI
LATOR
20
X
X
X
1,2
SWITCHES (ON. TIMER)
x
X
:MOTOR OPE
RATED DAMPER
24
X
X
1,2.
THERMOSTAT
24
X
x
REMARKS:
1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BL
ENDING UNIT VENTILATOR
MARK.
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
WATTS
VOLTS
PHASE
COMMENTS
115
.5" WG
32"Lx12. 25Wx8. 5"H
76.
120
I, 2, 3
NOTE:
I. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF ,ALEYES- AMERICAN
A, OR APPROVED EQUAL,
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
S'TATI C
PRESSURE.
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
SGI
115
<.08" WG
7"
7"
FLOOR
350
I, 2, 5, 6
90
<,:08" WG
6"
WALL.
WALL, CAP
I, 2, 3, 4
RG -I
25
‹.08" WG
4"
'FLOOR
35Q:
1, 2, 5, 6
REMARKS:
I. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2 PAINT To BE COORD1NATED WITH TECHNICAL REPRESENTATIVE
3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
4. BASIS OF DESIGN ALDES
A. OR APPROVED EQUAL,
5. BASIS OF DESIGN: SHOEMAKER
A. OR APPROVED EQUAL.
6: PROVIDE WITH AN OPPOSED BLADE DAMPER
WA
LL CAP SCHEDULE
MARK
LOCATION
CF
AIR
VELOCITY FPM
PRESSURE
SIZE
REMARKS
WC4
EXTERIOR:
90
337
TO;
1,2
REMARKS:
I. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN; FAMCC) HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE -CODE
FLOOR AREA
(SQ. FT.)
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.2224 MOD
1311
3
90 CFM
90 CFM
0810.03,2224 BV -I
339
90 CFM
90 CFM
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51-51-1508, TABLES MI508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION
vt
IN VALUE
NOTES
ON ROOF DR
ON EXTERIOR OF BUILDING
R-8 WITH WEATHERPROOF BARRIER
1.3
ATTIC, GARAGE. CRAWL. SPACE, IN WALLS. IN FLOOR/CEILING
R-8
1.2.3
WITHIN:CONDITIONED SPACE OR tN HEATED BASEMENTS
R-8
1.3
IN CEMENT SLAB OR IN GROUND
R-5
1.3
NOTES;
I, THICKNESS OF INSULATION IS: .DERNED A$ THE THICKNESS OF THE EAsicj:NsuLAT.ING
rv..EDufm NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY EE OMITTED ON THAT PORTION OF'.A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEILING SPACE **HERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED- TO CONDITIONED AIR.
3. REFER TO WASHINGTON TATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
IH
DRAWING .NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 011101 AND 028200 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED
TO EXTERIOR WINDOW TRIM PAINT.
ERMOSTAT/SWITCH HOURS OF OPERATION
SET FURNACE THERMOSTAT/SWITCH TO OPERATE: 1 OF EVERY 2 HOURS.
SET 8V-1 SWITCH TO OPERATE 1 OF EVERY 3 HOURS.
•
FURNACE MECHANICAL VENTILATION CALCULATION
PER WAC 51-51 M1508.3:
OF = QR (&ECR X F)
QR =. (FROM TABLE M1508.2) 4
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F FRACTION OF OPERATION 1/2
QF = 45 / (1 X 1/2) = 90 CFM
BV -1 MECHANICAL VENTILATION CALCULATION
PER WAC 51-51 M15083
QF = QR / (&EGR X F)
QR = (FROM TABLE m15o6.2)
&EGR - VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION la
QF = 30 / (1 x1/) = 90 CFM
b13-- o
SEPARATE
PERmir AND
APPROVAL
REQUIRED
RECEIVED
CITV OF TUMARA
I JAN tO 7 2013
PERMIT CENTEP
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Protean:1one Limited 11416114 Compway
4000. DELRIDGE WAY SW
SUITE 200 SEATTLE, Wit mos
(206) 624-2777 • PAY (200) 624-2078
THE GREENBUSCH GROUP, INC
)
)
46404011.44)
/11111111CAL, AU010 / 141303 k NECHVICAL ENO001G
1000 107 imcM saw SUITE 201 SEM VIA 0110
(200) 378-0569 (206) 370-0041 FAX
MPROVEMENTS
RESIDENTIAL A
AIP NUMBER
3-53-0058-044
DATE
06/05/2012
ISSUED 100% CO.
PROJECT ENGINEER
00
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M .0
0810.03.2224
DRAWING:NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR
3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51,
SECTION M1508.5.4.
3. SEE ELECTRICAL DOCUMENTS FOR. FURNACE WIRING MODIFICATION. AT THE
TIME OF FINAL INSPECTION„: THE WHOLE HOUSE FAN SHALL OPERATE FOR AT
LEAST 8 :HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY
THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51,..51,„ SECTION M1508.5.2
(CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF
OPERATING THE 'vENTILATioN SYSTEM wallow- ENERGIZING OTHER
ENERGY -CONSUMING APPLIANCES), COORDINATE FINAL TIME SETTINGWITH
PROJECT REPRESENTATIVE.
4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN
COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE
FOLLOWING:
A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR
UNIT SYSTEM(S) WITH NEW FILTERS.
90
FLAG ..NOTES;._
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL
CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL
SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE WSEC
1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL
TO .THE CONTROLLER THAT READS "WHOLE HOUSE
VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC
51-51, SECTION. M1508.5.2. COORDINATE FINAL SWITCH
LOCATION WITH HOMEOWNER.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM
DUCT INSULATION THICKNESS SCHEDULE ON M1.O.
EN -1 AND DUCTWORK ROUTED IN STORAGE SPACE.
COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH
WITH TECHNICAL 'REPRESENTATIVE.
LOWER FLOOR
SCALE: 1/4" = 11-0"
5TOAGE
NtEcHANICA...-,
PLAN
NORTH
HOLD DUCTS
TIGHT TO JOISTS
lb' EXIST.
ATTIC .ACCESS
PANEL
MA
I
N
FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1* -0*
441111NORTH
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECEIVED
CITY OF TUKWILA
I JAN ,0 7 2013
PERMIT CENTW
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Prote0010631 Maned Liabilit9. Cenvatny
4000 DELRIDGE WAY SW
SITE 2QO SMITLE, WA 08100
206) 624-2177 ^ 1AX (206) 62071673
THE. GREENBUSCH GROUP, INIC
0 66
*666j Ii
0
16211.111CAL DIONEERINO
TOrS iell"IVIEAU1112011322141° 101V11 1
011E 201 92222, 00110
206) 312-0569 (206) 378-0844 FAX
0810.03.2224
0
1:e
0
w
ce
0
0
0
IMPROVEMENTS
FT NOOSE REMED
RESIDENTIAL AIR
AIP NUMBER
3-53-0058-044
PATE
06105/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
PRAWN
JA, DT
MECHANICAL
FLOOR PLANS
M2.0
0810.03.2224
FLAG NOTES:
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E)
FURNACE IS WITHIN 4 FEET OF FURNACE RETURN
INLET PER WAC 51-51, SECTION M1508.5.1.
CUT DUCT AND INSTALL A VOLUME DAMPER ON
THE EXISTING FURNACE RETURN AIR DUCT.
VOLUME DAMPER SHALL ALLOW FOR BALANCING
THE OUTSIDE/RETURN AIR TO PROVIDE THE
SCHEDULED VOLUME OF OUTSIDE AIR. FIELD
VERIFY RETURN AIR DUCT SIZE PRIOR TO
ORDERING. IF A VOLUME DAMPER EXISTS IN THIS
LOCATION, IT MAY BE REUSED.
ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER
SWITCH BY TECHNICAL SPECIFICATIONS SECTION
16100. AFFIX A LABEL TO THE CONTROLLER THAT
READS "WHOLE HOUSE VENTILATION (SEE
OPERATING INSTRUCTIONS)" PER WAC 51-51,
SECTION M1508.6.4,
TRANSITION DUCT TO AIR TERMINAL NECK SIZE
IMMEDIATELY BEFORE MAKING FINAL GRILLE OR
DIFFUSER CONNECTION.
4T0 Ei V-1
25
KI TCHEN
2
SG -1
115
ATTIC
IS' x IV EXIST,
ATTIC AC4ESS
PANEL
MECHANICAL PLAN
SCALE: 1/4 = 111-0"
eNORTH
>-
OE
a-
Lti
lx
-U
IX
Li
FURNACE
CEILING
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
JOIST PER PLAN
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
RELD VERIFY SIZE
PRIOR TO ORDERING
MOD, INTERLOCK
TO FURNACE
FLUE.
POC
FLOOR:
FURNACE ELEVATION
SCALE: NONE
SHEETMETAL
TRANSITION TO WALL
CAP NECK SIZE
DUCT PER PLAN
CAULK
2X BLOCKING
2X BLOCK!. G
FOAM BACKER
ROD
WALL CAP
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL PER. MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORD. W/ARCHITECTURAL TECHNICAL DOCUMENTS,
REF. 1/A2.2 FOR DETAIL
P DETAIL
OUTSIDE AIR
DUCT
RETURN AIR
DUCT
MOD
By -1
HOLD TIGHT TO
STRUCTURE
SUPPLY AIR DUCT
NOTES:
MOTOR ACCESS
FILTERS ACCESS
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. VERIFY UNIT ORIENTATION. BEFORE INSTALLATION..
3. INSULATE ALL DUCT AS SCHEDULED.
BV -1 INSTALLATION DETAIL
SCALE: NONE
SLEEVE AND
ESCUTCHEON
2X BLOCKING
CAULK
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT, ROUTE
PER PLAN
FLOOR GRI
FLOOR:
LLE
2X BLOCKING.
FOAM BACKER
ROD
0 kb13---oo(ar
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS..
2.: SEE PLANS FOR VOLUME DAMPER LOCATIONS.
RECEIVED
CITY OF TUKWILA
JAN 0 7 2013
MIT CeiNr,
0 FLOOR GRILLE DETAIL
SCALE: NONE
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
EXPIRES; 9/08/2012
STEMPER
ARCHITECTS
A Frofeawimal Waited Liabiliky Ctmapow
4000 DELRIDGE WAY SW
SUM 200 SEATITS, wit 08108
(200) 024-2777 ^ PAX (200) 024-2272
THE GREENBUSCH GROUP, INC
AO0t1S2244 AIJC40 J vm� & MECHNICAL 10101WERINO
1000 WV WOMN STREET' KR 20 SWIM WA 11010
(200 370-0500 (200) 3700041 FAX
re
0
CL
re
7C -C
0
w.
re
z
z
0
0
0
MPROVEMENTS
FT NOISE REMEDY
RESIDENTIAL AIR
AlP NUMBER
3-53-0058-044
DATE
06/05/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
„IA, DT
MECHANICAL
FLOOR PLANS
AND DETAILS
M2.1
0810.03.2224
E
ECTRICAL - PROJEC NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3, MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDIIIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL.. ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NO ES
,PROVIDE: COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT, COORDINATE WORK WITH MECHANICAL DRAWINGs,
PROVIDE TIMER SWITCH AND COMPLETE CONNEC11ONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE.
HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY
CEILING OR WALL PENETRATION WORK.
,
• DEMO EXISTING PANEL.
USE As JUNCTION BOX,
EXTEND EXISTING: CIRCUITS
TO NEW PANEL
NEW PANE IMPL,. SEE
DETAIL AND PANEL
SCHEDULE
eNORTH
EF;JR0
1
CL 05E T
lan 18." EXIST.
4TTIC ACCESS
T.
TO PLIMIACE
GOMM
T
1
c14 -21\I
BED
ELECTRICAL LEGEND
5111E01, -
DESCRIPTION
SYtit01-
DSCRIPTION
LIGHTING OR POWER PANEL
Ilif
0
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR ocrs DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2*C. MIN. EMT OR RIGID STEEL INDICATES EQUIP GNI
INDICATES ISOLATED GROUND.
MAST, WEA1HERHEAD
BRANCH CIRCUIT HOME RUN.
D
E3'
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
DAMPER CONNECTION
NON-FUSED DISCONNECT SWITCH
TOGGLE TYPE MOTOR DISCONNECT SWITCH Will THERMAL OVERLOADS
SMOKE IDEICTOR
[al
ELECTRICAL MEIER
TIMER OPERATED SWITCH
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UIILITY.
CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT
NEW PANEL. SEE DETAIL
AND PANEL SCHEDULE
THERMOSTAT
UNE VOLTAGE FIRE ALARM SMOKE/CARBON
MONOXIDE DETECTOR
MECHANICAL / ELECTRICAL COO
!NATION
EQUIPMENT
NO.
CONTROL EQUIPMENT
DESCRIPTION
VOLTS PH
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVES ON
15
16
15
16
N/A
15
16.
N/A
REMARKS
BV -1
BLENDING UNIT VENTILATOR
120
1
X
X
1,2
SWITCHES (ON, TIMOR)
1 0
1
X
X
X
DEMO EXISTING PANEL
USE AS JUNCTION BOX.
INTERCEPT AND EXTEND
EXISTING CIRCUITS TO NEW
PANEL
CLO6ET
lp I NI:NCI:
fROON
f3E r-.) ROOM
METER AND FINAL
CONNECTIONS BY SCL.
INCLUDE ALL UTILITY
CHARGES IN BID.
PROVIDE NEW METER BASE,
RIGID STEEL MAST,
WEATHER HEAD AND
CONDUCTOR PIGTAILS PER
SCL REQUIREMENTS.
FINAL CONNECTIONS BY
SCL. INCLUDE ALL UTILITY
SERVICE FEES IN BID.
PROVIDE NEW WEATHER
HEAD, MAST GUYS AND
/— ANCHORS AT EXISTING
LOCAllON. PROVIDE
NEW ROOF FLASHING.
,,,PROVIDE MINIMUM 36w
CLEARANCE AROUND
SERVICE WIRES PER
SCL REQUIREMENTS.
MOTOR OPERATED DAMPER
THERMOSTAT
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
4 1
X
24 11 X•
X
X
L
LI
X
1,2
1
t
Ii– — • • ..,
1
r, L_
sEpAR„,
PemiiiAct
REQUAPPRovAL
IRED
RECEIVED
env OF TUWW111
I JAN .0 7 2013
PERMITCEnnfr
S.MSTEMPER
ARCHITECTS
A Profesahmal limited Liability Company
4000 DELRIDGE WAY SW
SUITE 20Q. SEATTLE, WA 9810Q
(206) 624-2777 • FX (206) 624-2973
INSINUURS.INO
11911 MTN MO ORM 61111111120
%Weft "A ONSMIS
Trumps Ole wit
fale 40 ass
0810.03.2224
NTERNATIONAL AIRPORT
z
0
0
AIP NUMBER.
MPROVEMENTS
F -
Cl)
w
5-53-0058-044
DATE
JUNE 7, 2012
ISSUED
100%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
El .°
0810.03.2224
PANELMP
•
......... „ .
LOCATION.
SE-RANG.,iiiaaHIDENC,EH
10,000
120/240
VOLT, 1 PHASE, 3 ME.
200 AMP with. MAR BIM
CKT LOAD DESCRIPTION
TYPE KVA
AP.
PHASE
KVA
TYPE
LOAD DESCRIPTION
CKT
1 EXISTING LO
20/2
14
I
.001.7rINGILOAta. • .
17 EXISTING LOAD
19 ExAmt_pAp_
21 EXISTING LOAD
23 EXISTING LOAD
30/1
20172
itht:
1511
1511
4511,,
15/1
154
2011
23„
EAST N
G LOAD
27
29
....
31.
30
35
. .
EXISTING37
LOAD
EXISTING LOAD
A
Et,
0012
20/1
B
A
A
15/1
EXISTING LOAD
2
4
PROVISION
PROVISION
PROVISION
PROVISION
8
10
12
20
22
24
A
41
a
A
B
A
28
30
32
34
36
38
: .
PHASE LOAD PHASEPHASE 0*-:
Vi
A
K
LM
TOTAL LOADS
CONN, LOAD
...
KVA
AMP
COMPUTED LOAD
AMP
ISOLATED GROUND
RAINTIGHTNEMA-3R
FEED THR&J WOS [j MAIN BKR SHUNT TRIP PANEL SKIRTS SURFACE
.......
DOUBLE LUGS SERVICE ENTRANCE ',1!:S.FTE•PRWTV.5asi', []FLUSH .
REMARKS.
PAN EL
LOCATION
••••••••• •••••••••••••••••vr....-------
ENC
. •'• '•• •
120/240:VOLT. I PHASE, L_WHE
• •
loxo:A10, -
, .::,... . .
•LOAD DESCRI
PT1ON
..P•
..:PHASE
...
KVA.
L6AO.DESCRIPTLOf-,1
.. . .
CKT
1 EXISTINGLOAD
!i!! .3..
3 30/1
.EXISTING LOAD
"
!!..Js
9 EXISTING LOAD 20/1
11.
t40wyPe: •
CONN. LOAD
COMPUTED LOAD.
..... , ..... .. .
A
ISOLATED GROUND
ENCLOSUREDOUBLE LUGS
P.501(14$.41tiEl .
2011
EXISTING LOAD
EXISTING LoAal
EXISTING LOAD
... . L..> • • :
susiDING UNIT
... .„. • •••
lAIN SKR SHUNT TRip
SERVICE etilAMOt080%
2
4
a,•-
12
KVA
AMP
PANEL SKIRTS DiSURFAZ't
.. .. , ..... . ... ... ,
NTOOlikTAM$ FLUSH
RE
.. .
••••:,]
.. ,
..•
PROVIDE NEW RIGID STEEL
MAST, WEATHER HEAD AND
CONDUCTOR PIGTAILS PER
SCL REQUIREMENTS.
FINAL CONNECTIONS BY
SCL. INCLUDE ALL UTILITY
SERVICE FEES IN BID.
PROVIDE NEW MAST
GUYS AND ANCHORS
PROVIDE METER BASE.
PER SCL STANDARD
pu13-44/NPAT-30
ROOF
z g
Um U. S.4
PROVIDE #4CU GROUNDING
ELECTRODE CONDUCTOR AND
GROUND RODS PER CODE.
MAX 10 OHMS TO GROUND
re, 3#3/0 CU
METER AND FINAL.
CONNECTIONS BY
SCL. I NCWDE ALL
UTILITY CHARGES IN
BID.
3#3/O CU.& GND
PROVIDE NEW NEMA --3R S.E. RATED
PANEL BOARD. INTERCEPT AND
EXTEND EXISTING CIRCUITS AND
CONNECT TO NEW BREAKERS.
PANEL Nip
200A
120/240.
1—PH, 3W
-PROVIDE NEW SERVICE \
DROP FROM POLE TO I,
HOUSE BY SQL. ALL
FEES PAID BY
CONTRACTOR.
1-1/4"C, 3#6 1#10G.
PROVIDE ALL REQUIRED CUTTING .AND: PATCHING. AS REQUIRED
TO COMPLETE THE WORK AS DESCRIBED ABOVE AND ON
DRAWINGS.
ROUTE CONDUIT EXPOSED ON OUTSIDE OF HOUSE. PROVIDE
STRUCTURAL SOLID 2X6 BLOCKING IN ATTIC FOR MAST.
PROVIDE BLOCKING AND UNISTRUT ASSEMBLIES TO HOLD
CONDUIT AWAY FROM HOUSE SURFACE TO ALLOW FOR EXISTING
CONDITIONS. VISIT THE SITE TO ESTABLISH EXACT CONDITIONS
PRIOR TO BID.
PANEL MP1
60A
120/240
1—PH. 3W
t3N- 00 b
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECENED
MP OF Tl MAMA
I JAN 0 7 2013
-frimot
SeMSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRID GE WAY SW
Sian 200 • ST ATTU , WA 98106
(208) 624-2777 • FAX (206) 624-2973
INOININNO. INO
ma MAN MD *111111% gum isso
1114:0s.014
Irturititea IMAM NW
MN 4111 *WM
0810.03.2224
0
0
Ce
0
j
IY
U -I 0
LL
0
0 —•=-
0
w
(.9
Z
MPROVEMENTS
AIP NUMBER
5-53-0058-044
SEATTLE WASHINGTON
DATE
JUNE 7, 2012
ISSUED
100%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR..
DRAWN
JAB
FLOOR
PLANS
NOTES
El 1
0810.03.2224