Loading...
HomeMy WebLinkAboutPermit D13-006 - ARAGON RESIDENCE - REMODELARAGON RESIDENCE 4610 S 124 ST D13-006 Cityef Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.nov Parcel No.: 0179000995 Address: 4610 S 124 ST TIIKW Suite No: Project Name: ARAGON RESIDENCE DEVELOPMENT PERMIT Permit Number: D13-006 Issue Date: 01/15/2013 Permit Expires On: 07/14/2013 Owner: Name: ARAGON D Address: 4610 S 124 , SEATTLE WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RDS , SEATTLE WA 98108 Contractor: Name: G & G SPECIALTY CONTRCTORS INC Address: 4633 S 36 ST , PHOENIX AZ 85040 Contractor License No: GGSPEGS919RT Lender: Name: Address: Phone: 206 296-7437 Phone: 480-921-4079 Expiration Date: 12/31/2013 DESCRIPTION OF WORK: RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE - WORK TO POTENTIALLY INCLUDE SELECTIVE REPLACEMENT OF WINDOWS, SELECTIVE REPLACEMENT OF INTERIOR/EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS, INSTALLATION OF SECONDARY SLIDING GLASS DOORS AND SKYLIGHTS, ETC. Value of Construction: $38,407.00 Fees Collected: $1,313.36 Type of Fire Protection: International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT **continued on next page** doc: IBC -7/10 D13-006 Printed: 01-15-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: Sanitary Side Sewer: Sewer Main Extension: Private: Storm Drainage: Street Use: Profit: N Water Main Extension: Private: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and ex governing this work will be complied Date: End Time: Fill 0 c.y. End Time: Public: Non -Profit: N Public: d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not pres - to give authority to violate or cancel the provisions of any other state or local laws regulating construction orae performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit Signature: Print Name: ® It Date: /—/S* 13 This permit shall become null and vbi d if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All wood to remain in placed concrete shall be treated wood. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary doc: IBC -7/10 D13-006 Printed: 01-15-2013 sewer connections, and properly fill orrwise protect all basements, cellars, septic t ;wells, and other excavations. Final inspection approval We determined by the building inspector ban satisfactory completion of this requirement. 8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D13-006 Printed: 01-15-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cLtukwila.wa.us Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 4610 S. 124th St. Tenant Name: Daniel Aragon Property Owners Name: Daniel Aragon Mailing Address: 4610 S. 124th St. King Co Assessor's Tax No.: 0179000995 Suite Number: Floor: New Tenant: 0 Yes ..No Tukwila WA 98178 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296-7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker@kingcounty.gov City State Fax Number: (206) 269-7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody@smstemper.com or tim@smstemper.com City State Day Telephone: (206) 624-2777 Fax Number: (206) 624-2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applicanons\Fotms-Applications On Line\2009 Applications \I-2009 - Permit Application.doc Revised: 1.2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 027099-9-A t Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? 0 Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? , 0 Yes m No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System – For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fomu-Applications On Line\2009 Applications\I-2009 - Petmit Application.doc Revised: 1-2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 1,630 2nd Floor 3`d Floor Floors thru Basement 1,243 Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? , 0 Yes m No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System – For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fomu-Applications On Line\2009 Applications\I-2009 - Petmit Application.doc Revised: 1-2009 bh Page 2 of 6 S PLUMBING AND GAS PIPING PERMIT INFORMATION - 206-431-3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen (>750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H: Apphcattons\Fotms-Applications On-Line\2009 Applications \1-2009 Permit Application:doc Revised: 1-2009 bh Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE ' : ��J�'. D AGENT: Signature: Date: Print Name: m• by Fenlason, SM Stemper Architects, PLLC Day Telephone: (206) 624-2777 Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 City State Zip Date Application Accepted: di 1,911 4 ,. Date Application Expires: 61I 01 I LS Staff Initials: H:' ppbcanons\Fomu-Applications On Line\2009 Applications\I-2009 - Permit Application.doc Revised: 1-2009 bh Page 6 of 6 City o'ukwilar Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Website. hitp•//wwwci trdavila.wa.us SET RECEIPT RECEIPT NO: R13-00124 Initials: JEM Payment Date: 01/09/2013 User ID: 1165 Total Payment: 13,045.45 Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE) SET ID: S000001897 SET NAME: KING COUNTY NOISE ABATEMENT SET TRANSACTIONS: Set Member Amount D13-004 1,018.34 D13-005 1,239.61 D13-006 1,313.36 D13-007 779.67 D13-008 1,116.68 D13-009 1,141.27 D13-010 1,313.36 D13-011 1,092.10 D13-012 1,239.61 D13-013 1,092.10 M13-003 167.70 M13-004 186.50 M13-005 177.10 M13-006 167.70 M13-007 177.10 M13-008 177.10 M13-009 124.25 M13-010 177.10 M13-011 167.70 M13-012 177.10 TOTAL: 3;68714— 1),/ o . i- _ TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 13,045.45 TOTAL: 13,045.45 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES 000.322.100 6,849.15 City c TTukwilar Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: hap:/lvww ci.tukw ila.wa. us STATE BUILDING SURCHARGE 640.237.114 45.00 TOTAL: 13,045.45 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 r_ (206) 431-3670 Permit Inspection Request Line (206) 431-2451 c3—ooh Prot; ► Al 0C% TYpeepi V Ar \IS U. t Address!,.S.s Date C II fd �! 6 r (0(o (IAi Special Instructions: ''' Date Wanted 2 1 3 (a.m. \!..,:..m Requester: Pron5lob ....... s( 0 09 (0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: I o Inspects 04 Date ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Jennifer Marshall From: Sent: To: Cc: Subject: Tim Fenlason <tfenlason@jonespayne.com> Tuesday, January 08, 2013 11:29 AM Jennifer Marshall sharyn.parker@kingcounty.gov; Jesse Holgate Re: KCIA RANRIP Submittal You are correct. I'd like you to change the applications to reflect the amounts in the pink column. I thank you for this extra work and if you'd like, I can gladly drive to your office to make the changes. On Tue, Jan 8, 2013 at 9:56 AM, Jennifer Marshall <Jennifer.Marshall@tukwilawa.gov> wrote: Good morning Tim, Due to the fact that I cannot just arbitrarily change information on permit applications, I am clarifying the direction you are giving me. Are you directing me to update the valuations provided on the applications submitted yesterday to the numbers below under the column highlighted pink and labeled "Value Originally Provided?" Applicant Name Ochoa Residence Nguyen Residence Aragon Residence Aragon Residence Carter Residence Christensen Residence Fasano Residence Kerr Residence Nguyen/Diem Residence Rivera Residence Address 1186344Av S 5016 Wallace St 4610 S 124 St 12245 46 Av S 1180240P1S 12212 48 Av S 12029 44 Av S 3834 S 116 St 11620 40 Av S 11826 44 P1 S Dev Permit Value Provided on No Application Value Originally Provided D13-004 $24,018.00 $26,622.00 D13-005 $31,135.00 D13-006 $32,099.00 D13-007 $17,201.00 D13-008 $25,472.00 D13-009 $28,169.00 D13-010 $37,403.00 D13-011 $23,133.00 D13-012 $33,129.00 D13-013 $23,619.00 $35,359.00 $38,407.00 $19,973.00 $30,978.00 $31,174.00 $38,918.00 $29,764.00 $35,722.00 $29,761.00 If these numbers are correct please respond accordingly and I place a copy of these emails in the file proving that I have been authorized to make the changes. If they are not correct, please provide me with the correction valuations. Thank you, Jennifer Marshall Permit Technician Original Message From: Tim Fenlason [mailto:tfenlason@jonespayne.coml Sent: Monday, January 07, 2013 4:18 PM 1 To: Jennifer Marshall o • Cc: sharyn.parker@kingcounty.gov; Bill Rambo; Jesse Holgate Subject: Re: KCIA RANRIP Submittal Jennifer, My preference would be to use the amount provided to Bill and to update the applications. I know that the amounts provided to Bill are correct, as I did those calculations myself. On Mon, Jan 7, 2013 at 4:08 PM, Jennifer Marshall <Jennifer.Marshall@tukwilawa.gov> wrote: > Good afternoon Tim, > I received the applications and plans for ten lots for the above > referenced project. I have completed the data entry in our permit > system and discovered there are discrepancies with valuations provided > to Bill Rambo and the valuations provided on the applications. I have > attached a spreadsheet showing those discrepancies. The issue with > there being a difference is that the permit estimate provided from > Bill is no longer applicable. > It is the end of my work day, so I will wrap this up tomorrow morning > (I probably will not be able to fit it in until about 10 am) and > provide the updated permit fees which will correspond with the new > valuations given. At that point we will need payment to be made > before the permits can begin the review process. I have also attached > the original worksheet you and Bill were working with for your reference. > Have a good evening. > Jennifer Marshall > Permit Technician, City of Tukwila > T: 206 431-3670, F: 206 431-3665 > ]ennifer.marshall@tukwilawa.gov Tim Fenlason Associate AIA Senior Job Captain 2 *EMT COORS COP PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-006 DATE: 01./07/12 PROJECT NAME: ARAGON RESIDENCE SITE ADDRESS: 4610 S 124 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Works fIVIQ 0 01' 10. Fire Prevention 111 Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete E] Comments: Incomplete ❑ DUE DATE: 01/10/13 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/07/13 Approved ❑ Approved with Conditions k Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeopi Printer Friendly Page General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company G & G SPECIALTY CONTRCTORS INC 4809214079 4633 S 36Th Street Phoenix AZ 85040 Out Of State Corporation G & G SPECIALTY CONTRCTORS INC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602975812 Active GGSPEGS919RT Construction Contractor 12/31/2009 12/31/2013 General Unused Business Owner Information Name Role Effective Date Expiration Date GOODBALLET, CHARLES ELMER Chief Executive Officer 12/28/2009 Bond Amount WAVY, CHRISTINE Chief Operating Officer 12/28/2009 59BSBEA9058 GOODBALLET, JAMES SCOTT President 12/28/2009 GOODBALLET, TERESA LYNN Secretary 12/28/2009 INS CO OF THE WEST Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 HARTFORD FIRE INS CO 59BSBEA9058 12/18/2010 Until Cancelled $12,000.00 01/03/2011 1 INS CO OF THE WEST 2278440 12/18/2009 Until Cancelled $12,000.00 12/28/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 Companion Property & Cas Ins C PCP10000270101 11/03/2012 11/03/2013 $1,000,000.00 11/16/2012 3 National Union Fire Ins of PA PCP1000027 11/03/2011 11/03/2012 $1,000,000.00 12/27/2011 2 LEXINGTON INS CO 4392611702 12/31/2010 12/31/2011 $1,000,000.0001/11/2011 1 CO LEXINGTON INS 4392611701 12/31/2008 12/31/2010 $1,000,000.0001/14/2010 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 01/15/2013 KI NG CO U N TY INTERNATIONAL AIRPORT RCRAFT NOIS. E REMEDY IM PROV.EMENTS PRO:Q:1RM • SCORE. 'OF -WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORIATION IN THE DRAWINGS AND SPECIFICATIONS INCLUDING BUT NOT LIMITED TO: APP YES LI: ABLE NO I. SELECTIVE REPLACEMENT OF EXISTING WINDOWS. WITH NEW VINYL -FRAMED ACOUSTICAL. WINDOWS. X 2. CUT DOW OF UJINDOWS TO cotortx w1t14 EGRESS REQUIREMENTS. X 3. INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL ODORS. X 5. INSTALLATION OF STORM DOORS. 6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X O. INSTALLATION OF PET DOORS. X 9. INSTALLATION OF FIREPLACE FRESH AIR vENT. X 10. IN4LLA.ION. OF CHIMNEY CAP. X 11. REGULATED MATERIALS ABATEMENT. X 12. ATTIC VENT BAFFLES. 13. INSTALLATION. OF Artic INSULATION. X 4. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 15. INSTALLATION OF MECHANICAL. VENTILATION EQUIPMENT, FUR. ACE MODIFICATION AND ASSOCIATED. DUCTING. X 16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 18. INSTALLATION OF SMOKE DETECTORS. X I% NEW ELECTRICAL PANEL / SERVICE. X 20. KNO0:4NPIT.IDE X SEPARATE PERMIT REQUIRED FOR: leAsChankud BrElectrical grIblumbing 7as Piping City of Tukwila Et fi.r.IING DIVISION Permit No. Ei copy 049 -‘eini approval is subject to errors and omissions. cif construction documents does not authorize . a y adopted code or ordinance. Receipt is aclmowledged: 0 Al Aw40046.- ANA By Date: City Of lbkwlta BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tulavila Building Division. irT:: revisions will require a new plan submittal C.ml may inciude additional plan review fees. C00747Q12 BIP: PACKAGE .M-3,3 3-53-0058-044 SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City -of Seattle, WA APPLICABLE CODES: 2005 International Residential Code, International Pim; Code, International Mechanical Code :�I1000.sss ZONING: 5F1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION, TYPE:: ,(No: Change). V B NON.SPRINKLEREP LEGAL DESCRIPTION; LOTS 21 AND 22, BLOCK 5, ALLENTOWN ADDITION. TO THE CITY OF SEATTLE, ACCORDING TO THE PLAT RESEARCH IN VOLUME 12 OF PLATS, PAGE 100, IN KING COUNTY, WASHINGTON. 4, • ' - DRAWING INDEX T0.0 TITLE, SHEET, PROJECT INFa A1.0 FLOOR PLANS 4 NOTES A2.0 WINDOW TypES, SCHEDULE 4 DETAILS - A2.1 DOOR TYPES, SCHEDULE 4 DETAILS. A22 MISCELLANEOUS DETAILS 423 WINDOW .FLASHING DETAILS 111.0 LEGENDS,SCHEDULES, ASEREV., GENERAL NOTES 4 DWG INDEX 112AND DETAILS MECHANICAL KAN E1; M5ELCWECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING 'COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph 206. 263. 9233 Fax 206, 296. 0190 Contact: Sharyn Parker E-mail: SharynParttertokincjcounty.gov ARCHITECT: 531 .5temper Architects P.L.LC. 4000 patricide Way SW, Suite 200 seogit..LUA 98100. Ph: 206, 624:2111 Fax: 206. 0024. 297I3 Contact: Jerry Osborn, Melody Leung, - Tim Fenla son, E-mail: jerlasmstempercom meloclyeamstenVetcoM thtigenistemperooin ACOUSTICAL ENG:NEER: SM Acoustics 222 Etruria Strc*:Suite 100 Seattle WA 98109 Ph 206. 835. 0819 Fax: 206. 839. 0024 Contact; Mohamed Aft Allaoua E-mail: mohamedessaacoustice.ccm MECHANICAL ENGINEER: The Greenlausch- Group 1900 West Nickerson St., Suite 201 Seattle, WA 58119 Ph 206 318 0569 Fax; 206. 31S. 0641 Contact: Dylan Turner E-mail: DylanTfigreesnbusch.com ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253. 412. 3463 Contact: Brent Rollins E -mall: bcretresuost.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 96102 Ph: 206. 232. 9639 Fax: 206. 162. 4180 Contact: Tim Ogden E-mail: tim ogdenspbsenv.com clgso SUPPORT SERVICES The Jones Pane Group 123 North Washington St. 0200 !Boston, MA 02114 Contact: Tim Fenlason, Cynthia Maeda E-mail: crlaeolaojonespaynezom REVIEWED FOR STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 58121 Ph 206. 622. 4580 Fax: 206. 622, 0422 Contact: Ron Martinson ronm.psm-engineers.com VICIN ITY MAP (NTS) CODE COMPLIANCE APPROVED JAN 1 1 2013 City of Tukwila BUILDING DIVISION RECEIVED crry OF TUKWILA I JAN ,0 7 20131 PERMIT CENTER '' '' '' '' '''''' '' '''' ••• /•/'/'" „ ...................... ....................... ........................... ........................... ........................... w••••••••• ......... ...,...... .„ .....„... • „ "."..... ............. ............... . „ ........... ,........... „............... ................. ........., ........................ ....,..., ................ „..„........... .......... .............. •• •••••••"- ........„ . • ' • NORTH S.M.STEMPER ARCHITECTS Professional Limited Liability Company SUIQ°T0S20DOE'LSRETADTGTELE7IAVAY.. 987106 (208), 024 -?777. FAX (200 824-2o73 ,sco.fr : OF 0810.032224 < JUNE 7, 2012 0 0 611 LU ce U -I LU 0 z LL z OD Ce° 0< -1 U] 0 co MPROVEMENTS AIP NUMBER 355-00584044 z 0 ›ai -J DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT .JO PROJECT MANAGER ML&TF DRAWN LB&CP PROJECT INFORMATION, DRAWING INDEX, DIRECTORY TO.0 0810.03.2224 GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK of THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 500 FM TO &.00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT POOR OR WINDOW IS ON SITE. REMOvAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 500 AM AND ':00 PM.. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW. FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST ISE PROVIDED:. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RECONSTRUCT' SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE. SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS: PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL. FOR TIMER LOCATION 18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. 19. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 35" CLEAR IN FRONT OF CONTROL PANEL INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 2a MAXIMUM POUTER OUTAGE IS EIGHT HOURS. PO lLER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 PM. PLAN KEYNOTES ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW' SCHEDULE. O DEMOLISH EXISTING DOOR(S), FRAME, CASING; TRIM AND THRESHOLD. INSTALL NEW EXTERIOR. DOOR, FRAME, CASING, TRIM, THRESHOLD AND STORM DOOR REF. DOOR SCHEDULE. OINSTALL NEW SECONDARY SLIDING DOOR(S). REF. DOOR SCHEDULE. 0 DEMOLISH EXISTING DOOR(S), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE. FLUSH SOLID CORE INTERIOR WOOD DOOR WITH TRIM PACKAGE BOTH ELEVATIONS, INCLUDE INTERIOR HARDWARE SET. REMOVE (E) FLOOR GRILL AND PATCH FLOOR WHERE GRILL WAS REMOVED TO ACCOMMODATE INSTALLATION OF: SECONDARY SLIDING O GLASS DOOR. INSTALL FLOOR GRILL ADJACENT TO SECONDARY SLIDING GLASS DOOR. CAREFULLY REMOVE (E) FLOORING AS REQUIRED TO ACCOMMODATE FLOOR GRILL INSTALLATION. DO NOT REMOVE (E) FLOORING EXCEPT UMAT IS NEEDED FOR INSTALLATION OF FLOOR GRILL. COORD. DUCT WORK WITH MECH. DOCUMENTS. OCOORDINATE FLOOR GRILL WITH MECHANICAL DOCUMENTS. OINSTALL VENT BAFFLES) AT EXISTING ROOF VENT(S) IN ATTIC. REF. 3/422 FOR DETAIL. O BLENDING UNIT LOCATED AND INSTALLED IN STORAGE ROOM, REF: MECI-. FOR UNIT,. REF, ELECT; FOR SPEED CONTROL AND DISCONNECT. REF. 4/422 FOR DETAIL. C..) INSTALL THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS. 10 INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL: AND ELECTRICAL DOCUMENT&. II INSTALL NEW ELECTRICAL SERVICE AND NEW ELECTRICAL PANEL. COORDINATE WITH ELECTRICAL DOCUMENTS. ODEMOLISH. EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422. FOR DETAIL. COORDINATE WITH 12 MECHANICAL DOCUMENTS. ACCESS TO SITE. AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. LEGEND ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE Nil ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH.: FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW 1111111111111 GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MIN. OF 24"FROM'EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 ATTIC INSULATION ATTIC INSULATION DAM INSTALL BATTERY OPERATED SMOKE DETECTORS INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER SOFFIT FOR MECHANICAL DUCTING. SPECIAL NOTES:. NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT, AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01 11 01 AND 02 82 00 FOR REGULATED MATERIALS ABATEMENT.. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 11 01 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PANT. NOTE: KNOB AND TUBE WIRING PRESENT. �-- PRIOR TO COMMENCING WITH DEMOLITION A "pre -demo inspection" is required. Contractors shall provide documentation that an "asbestos survey" has been completed. If needed, abatement procedures per "Puget Sound Clean Air Agency" shall be completed and documentation of compliance shall be provided at time of final inspection. STORAGE STORAGE LOWER FLOOR PLAN A. SOUTH ELEVATION. B. WEST ELEVATION C. NORTH ELEVATION D. EAST ELEVATION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 1 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TR D'WH IJAN 0 7 2013 9EI MITCENE.F S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELIZID GE WAY SW SUITE 200 • SEATTLE, IYA 98106 (206) 624-2777 • FAX (206) 624-2973 4220 t.r.... f.jy "RED 0810.032224 JUNE 7, 2012 c° O 0 J z 0 Z ce LU F z z 0 U z MPROVEMENTS D W ce W W 0 z ce AIP NUMBER 3-53-0058-044 Z O LtlicF - z DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES A1 .0 0810.03.2224 GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.: 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8•.00 AM EACH DAY. HOMEOWNERS WILL NAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS N THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8•.00 AM AND 5:00 PM.. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 1 ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT, '3. EXISTING WINDOW COVERINGS MUST SE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. is INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK PAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT SHELVING N COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTE1.41 WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND .CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 18 INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. IS CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE; SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. PORTER MUST SE PROVIDED AT RESIDENCE 8:00 AM. 4 AFTER 5:00 Pit PLAN KEYNOTES 0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. DEMOLISH EXISTING DOOR(S), FRAME; CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND �STORM DOOR. REF. DOOR SCHEDULE. QINSTALL NEW SECONDARY SLIDING DOOR(S). REF. DOOR SCHEDULE. 0 DEMOLISH EXISTING DOOR(S), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE. FLUSH SOLID CORE INTERIOR WOOD DOOR WITH TRIM PACKAGE BOTH ELEVATIONS, INCLUDE INTERIOR HARDWARE SET. REMOVE (E) FLOOR GRILL AND PATCH FLOOR WHERE GRILL WAS REMOVED TO ACCOMMODATE INSTALLATION OF SECONDARY SLIDING O GLASS DOOR INSTALL FLOOR GRILL ADJACENT TO SECONDARY SLIDING GLASS DOOR CAREFULLY REMOVE (E) FLOORING AS REQUIRED TO ACCOMMODATE FLOOR GRILL INSTALLATION. DO NOT REMOVE (E) FLOORING EXCEPT WHAT IS NEEDED FOR INSTALLATION OF FLOOR GRILL. COORD. DUCT WORK WITH MECH. DOCUMENTS. 0 COORDINATE FLOOR. GRILL WITH MECHANICAL DOCUMENTS. ( ) INSTALL VENT BAFFLES) AT EXISTING ROOF VENTS) IN ATTIC. REF. 31422 FOR DETAIL. 0BLENDING UNIT LOCATED' AND INSTALLED IN STORAGE ROOM, REF. MECH. FOR UNIT, REF, ELECT, FOR SPEED CONTROL AND DISCONNECT. REF. 4/A22 FOR DETAIL. () INSTALL THERMOSTAT: COORDINATE. WITH MECHANICAL DOCUMENTS. 10 INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL DOCUMENTS. 11 . INSTALL NEW ELECTRICAL SERVICE AND NEW ELECTRICAL PANEL. COORDINATE WITH ELECTRICAL DOCUMENTS. DEMOLISH EXTERIOR WALL. ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A22 FOR DETAIL. COORDINATE WITH C.) MECHANICAL DOCUMENTS. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. LEGEND _Li„.,..,.,,,., ,,�,.y,.,,,,,»,.�,a,.,.LL. ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW „IIIII1111 GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST SALE FEATHER TEXTURED CEILING OVER AT' A MIN. OF 24” FROM EDGE OF PATCHING.. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL CEILING DEMOLITION. FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. REF..MECH.. t ELECT. REF: GENERAL NOTE 11 F--- ATTIC INSULATION ATTIC INSULATION DAM SO INSTALL BATTERY OPERATED SMOKE DETECTORS SG INSTALL .BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS IGAS GAS METER SOFFIT FOR MECHANICAL DUCTING. SPECIAL NOTES: NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURE$. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01 11 01 AND 02 82 00 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. Itkl-kms TO SECTION 01 1101 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT: NOTE: KNOB AND TUBE WIRING PRESENT. r B CLOSET 18 x 18" EXIST. ATTIC ACCESS PANEL LIVING BOOTH (E) FIRE PLACE INSERT J/ STORAGE 134TH KITCHEN 1 CLOSET BEP OOM 2 SITTING BEDROOM 3 DINING ROOM 0 0 1 • (E) GRILL TO BE REMOVED » m » » PATCH FLOOR OPENING MAIN FLOOR PLAN RUM A. SOUTH ELEVATION B. WEST ELEVATION C. NORTH. ELEVATION D. EAST ELEVATION brva REVIEWED FOR CODE COMPLIANCEy� APPROVE0 1 JAN 11 2013 City of Tukwila BUILDING DIVISION RECEIVEDECrilv or a rs 'JAN 0 7 2013 9A! S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, IYA 95106 (206) 624-2777 • FAX (206) 624-2973 :.» 1c£S E Y tib 0810.03.2224 JUNE 7, 2012 F- 0 0 J z 0 z W F- z z 0J �✓ 0 z AIP NUMBER 3-53-0058-044 DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES A1.1 0810.03.2224 GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WOW DAILY. 3. HOMEOWNER SHALL I4AVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO &00 All EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE. REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE; REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN &.00 AM AND 5:00 P1'1. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. S. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT: 9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL, IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. II. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT` SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENT& RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR, THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL 13E CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK. REFER TO ELECTRICAL FOR TIMER LOCATION 16 INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET Al FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. 19. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE; 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20, MAXIMUM POWER OUTAGE IS EIGHT HOURS. PC .ER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. t AFTER 5:00 :P1'1. PLAN KEYNOTES 11) DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. O DEMOLISH EXISTING DOOR(S), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR FRAME, CASING, TRIM, THRESHOLD AND STORM DOOR. REF. DOOR SCHEDULE. 0 INSTALL NEW SECONDARY SLIDING DOOR(S). REF. DOOR SCHEDULE. G/';1 DEMOLISH EXISTING DOOR(S), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE. FLASH SOLID CORE INTERIOR WOOD' DOOR WITH TRIM PACKAGE BOTH ELEVATIONS, INCLUDE INTERIOR HARDWARE SET: REMOVE (E) FLOOR GRILL AND PATCH FLOOR WHERE GRILL WAS REMOVED TO ACCOMMODATE INSTALLATION OF SECONDARY SLIDING 0 GLASS DOOR. INSTALL FLOOR GRILL ADJACENT TO SECONDARY SLIDING GLASS DOOR. CAREFULLY REMOVE (E) FLOORING AS REQUIRED TO ACCOMMODATE FLOOR GRILL INSTALLATION. DO NOT REMOVE (E) FLOORING EXCEPT WHAT IS NEEDED FOR INSTALLATION OF FLOOR GRILL. COORD. DUCT WORK WITH MECH. DOCUMENTS. 0 COORDINATE FLOOR GRILL WITH MECHANICAL DOCUMENTS. OINSTALL VENT BAFFLE(S) AT EXISTING ROOF VENT(S) IN ATTIC. REF. 3/A22 FOR DETAIL. ``J 0 BLENDING UNIT LOCATED AND INSTALLED IN STORAGE ROOM, REF: MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 4/422 FOR DETAIL. 0 INSTALL THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS, i0 INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL. DOCUMENTS. 11 INSTALL NEW ELECTRICAL SERVICE AND NEW ELECTRICAL PANEL. COORDINATE WITH ELECTRICAL DOCUMENTS. 0 MECHANICAL DOCUMENTS.DEMOLISH EXTERIOR WALL. ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A1.2 FOR. DETAIL. COORDINATE WITH. ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. LEGEND r r ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW 1111111111111 GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MIN. of 24" FROM EDGE OF PATCHING. '; MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. y , REF,_ MECH., 4 ELECT. REF. GENERAL NOTE 11 r----- ATTIC INSULATION ATTIC INSULATION DAM SD INSTALL BATTERY OPERATED SMOKE DETECTORS CD INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER. SOFFIT FOR MECHANICAL DUCTING SPECIAL NOTES:. NOTES: I. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01 11 01 AND 02 82 00 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01' II 01 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT: NOTE: KNOB AND TUBE WIRING PRESENT. 1"1'-2" TI•%' I.I. - 1'1 1I r ❑6 FOYER BATH 2 11 • • I" -A- • ..—: �� I .1 1 I / .16"„x 14.«- 1(01 ATTIC ACCESS PANEL • . . . .. �( . . • • • . . . . . ; .1 . _ • GS • • • • STUDY KITCHEN 2 .......... 4.1-1 .J'� • rIlk • AA At • I0'_2" • '_6" TVP. • 14'-3" 16'—IPS J ATTIC/ UPPER FLOOR PLAN 114"=1'-0" A. SOUTH ELEVATION B. WEST ELEVATION C. NORTH ELEVATION D. EAST ELEVATION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 11 2013 • City of Tukwila BUILDING DIVISION RECEIVED CITY OF TU$(WI(A JAN 0 7 2013 PERMIT CENTEF !%/ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 ra (1 I: s w. 0810.03.2224 JUNE 7, 2012 F- 0 0_ aC J z 0 z F - z z 0 U C z AIP NUMBER MPROVEMENTS 3-53-0058-044 DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES A1 .2 0810.03.2224 WINDOW TYPES L 2. HORIZONTAL DOUBLE HUNG XX -SLIDER 4. FIXED SLIDER/ FIXED/ SLIDER 5. CASEMENT WINDOW SCHEDULE WIND. NO ROOM LOCATION TYPE SIZE W x H TRIM FINISH INT../ EXT. REMARKS DETAIL SET LIVING ROOM 4 1-5u x STAIN/STAIN. SAFETY GLAZING REQUIRED, REMOVE 4 REINSTALL SHUTTERS 1/421). B LIVINGROOM 31-10" x 31.10" STAIN/STAN REMOVE 4 REINSTALL. WINDOW SHUTTERS 2/42.0 C LIVING Roar] 31-10H x 31-10" STAIN/STAN REMOVE -4IREINSTALL WiNpap.SHUTTERS •2/A2 0 BEDROOM:1 4'*0! 2'4" etTAIN./STAiN. REMOVE 4 REINSTALL WINDOW SHUTTERS 1/4.0 E BEDROOM I 2C10" STAIN/STAIN SAFETY GLAZING REQUIRED I/A20 F KITCHEN 2 7.60 x 314" STAIN/STAIN G KITCHEN 2 x.: 31.70" ISTAIN/STAIN 3140 1.4 KITCHEN 4'4" x sTAN/STAN. 1/A20 J •BEDROOM 2 SITTING ROOM 41-0" x 2"--4" 41-5" X 3" -Ir STAN/STAN S, AN/STAIN SAFETY GLAZING REQUIRED 2/42.0 I/A2.o K BEDROOM .3 2LS" Ix 4C2U- STAN/STAIN 1/A2.0 L M BEDROOM IsEDRocts1 3 3'-'1011 V.I0" STAIN/STAN - STAN/STAIN .1/40 N. BEDROOM 3 X 1.1.:100 STAN/STAIN .11A20 BEDROOM 3 31-10u x 1,-10u STAIN/STAIN 1/42.0 BEDROOM 3 3 2'.10" x P-10" STAIN/STAN 1/A21) BEDROOM 4. 3"-10" x STAN/STAN SAFET GLAZING REQUIRED I/A2o R KITCHEN 4'40" :x 2'40". STAN/STAIN SAFETY GLAZING REQUIRED 1/440 TYPICAL WIN DOW SCHEDULE NOTES 1, NQTE.c WHERE SAFETY LAZING.GIS INDICATED, BUT NOT SCHEDULED IN .SECTION QS 00'00,'Al4„1J.NLAMINATED: GLAZING PANELS:, IN THAT UNIT ARE TO BE TEMPERED. i;,-Am.INATED:oLAZtNQ PANELS NEED, NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS. SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND. WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO ;START' OF WORK. 4, FOR HEAD:- FLASHING INSTALLATION REFER TO HEAD .:FLASHINIQ, DETAIL:WON WINDOW TYPES, SCHEDULE & DETAILS SHEET, 1 HEMMED EDGE I I END CLOSURE A HEAD FLASHING " 3" 1' - 0" DETAIL TYP. (E) BACKER BOARD LE) VINYL SIDING UNDETERMINED VINYL SIDING SUBSTRATE cARERILLY LIFT CE) wALL,,UNPERLAYMENT :AND INSTALL TOP EDGE Of SEI.„F :ADHERING MEMBRANE AGAINST SHEAVING. LAP OVER METAL FLASHING. AND EXTEND SELF ADHERING ,FLASHING 4" UP WALL FROM TOP FLASHING. LAP CE) WALL UNDERLAYMENT OVER 'TOP OF SELF ADHERING FLASHING REMOVE (E)VINYL SIDING AS REqp FOR INSTALLATION EOF WIN -pow LASHINa REPLACE/ RE -INSTALL SIDING 4, ACCESSORIES TO MATCH . VINYL J C144NEL TRIM PRE..PRIMED, GALV SHEET METAL PLASHING UNDER SELF -ADHERING MEMBRANE. COLOR. TO BE SELECTED IN THE FIELD CE) EXTERIOR SHEATHING CE) WALL UNPERLAYMENT SELF ADHERING MEMBRANE TOUCH UP PAINT, AS REQID ACOUSTICAL WINDOW ASSEMBLY. CE) BACKER BOARD (E) BUILDING PAPER UNDETERMINED VINYL. sIDING„..sUBSTRATE: WIN DOW HEAD .. CONTINUOUS SEALANT, TYR SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP UP BATT INSULATION SEALANT •4 BACKER ROD CAREFULLY REMOVE CE) VINYL: 'MEMBRANE. INSTALL: SOLID INSTALLATION:OF SELF ADHERING, SIDING. CUT 1sApc:fp. BACKER: BOARD AND ,(5) AMYL roR: ISLOCKIN4 TO PROVIDE NAILING fOR.BACKER.BOARD„ RE- INSTALL REPLACEMENT BACKER:BOARD (E) VINYL :SPINS: (E) EXTERIOR 'SHEATHING TOUCH UP PAINT, AS REM? CONTINUOUS SEALANT, TYP. CE)au5 BACKER ROD 4 SEALANT SOLID WOOD TRIM JAMBLINING. FINISH TO MATCH (E) BACKER ROD SEALANT ACOUSTICAL WINDOW ASSEMBLY SELF -ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY. SEALANT 4 BACKER Rol) VINYL J CHANNEL TRIM WINDOWJAMa.. SHIM AS NECESSARY FILL GAP WI BATT INSULATION SEALANT 4 BACKER ROD 14,": 3/4" WOOD SILL SOLID WOOD TRIM •SELF -ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT 41I. CONTNUOUS SEALANT, TYP. TOUCH UP PANT, AS REQ'D UNDETERMINED VINYL. SIDING SUBSTRATE CAREFULLY REMOVE TOP COURSES OF (E) VINYL SIDING AND BACKER BOARD FOR NOTALI_ATIc7N OP WINDOW ASSEMBLY 4 TRIM. REPLACE/ RE -INSTALL SIDING TO MATCH CE) •(E) BACKER BOARD (E) VINYL SIDING VINYL SID 37-1,- WIN DOW SILL ING - WI NDOW DETAIL SET CE) ate CE) BACKER BOARD (E) VINYL SIDING UNDETERMINED VINYL SIDSUBSTRATE CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP Of FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING PLASHING REMOVE (E) VINYL sIDNG AS REO'D FOR INSTALLATION OF WINDOW 4 FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCESSORIES TO MATCH (E), (E) EXTERIOR SHEATHING VINYL J CHANNEL TRIM PRE -FIRMED, GALV SHEET METAL. FLASHING UNDER SELF -ADHERING MEMBRANE. COLoR TO EsE SELECTED IN THE FIELD ACOUSTICAL WINDOW ASSEMBLY. CE) BACKER BOARD r""*••••-.... CE) WALL UNDERLAMENT (E) WD. PANELING SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM UNDETERMINED VINYL SIDING SUBSTRATE VINYL CHANNEL TRIM. BACKER ROD 4 SEALANT. ACOUSTICAL WINDOW ASSEMBLY SELF -ADHERING MEMBRANE WINDOW HEAD SHIM AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER Rot.. •CAREFULLY REMOVE CE) VINYL SIDING. CUT BACKCE) BACKER BOARD AND(E) VINYL SIDING FOR. INSTALLATION OF SELF ADHERING MEMBRANE. INSTALL SOLID p.T. •I3LOCXING To. PROVIDE NAILING FOR BACKER BOAV. RE- INSTALL REPLACEMENT BACKER BOARD 4 (e) VINYL Sit NS CE) UP. PANELING CONTINUOUS SEALANT, TYR SOLID WOOP TRIM ACOUSTICAL WINDOW. ASSEMBLY. SEALANT 4 SACKER ROD VINYL J CHANNEL TRIM WINDOW JAMB UNDETERMINED VINYL SIDING SUBSTRATE CAREFULLY REMOVE TOP COURSES OF CE). VINYL SIDING AND SACKER BOARD FOR INSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE/ RE -INSTALL SIDING TO MATCH (E) CE) BACKER BOARD CE) VINYL SIDING VINYL SI 311.= 11 - 0" WP JAMB LINING SEALANT SWIM AS NECESSARY FILL GAP WI BATT INSULATION /4" BACKER ROD 4 SEALANT 3/4" WOOD SILL SOLID WOOD TRIM WINDOW SILL DING -WIN A DOW DETAIL SET CONTINUOUS SEALANT, TYP. SELF -ADHERING MEMBRANE CE) WD. PANELING CE) BACKER BOARD (E) vNYL SIDING UNDETERMINED VINYL SIDING SUBSTRATE CAREFULLY LIFT CE) WALL UNDERLAYMENT AND INSTALL TOP EDGE. OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL PROM TOP OF FLASHING. LAP CE) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING REMOVE CE) VINYL SIDING AS REM" FOR INSTALLATION. OF WINDOW 4 FLASHING. REPLACE/ RE -INSTALL SIDING 4 ACCESWRIES TO MATCH (E). VINYL J CHANNEL TRIM PRE -PRIMED, GALV SHEET METAL FLASHING UNDER SELF -ADHERING MEMBRANE, COLOR 10 BE SELECTED IN THE FIELD ACOUSTICAL WINDOW ASSEMBLY. (E) BACKER BOARD CE) EXTERIOR SHEATHING .(E) WALL UNDERLAYMENT CE) WD. PANELING SELF ADHERING MEMBRANE UNDETERMINED VINYL SIDING SUBSTRATE VINYL J CHANNEL TRIM BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY SELF -ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY. SEALANT 4 SACKER ROD VINYL J CHANNEL TRIM II I WINDOW' HEAD CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP WI BATT INSULATION SEALANT *SACKER ROD CAREFULLY REMOVE (E) VINYL SIDING. OUT •134cK ,(E) BACKER BOARD AND CE) VINYL SIDING FOR INSTALLATION OF .SELF ADHERING MEMBRANE. INSTALL SOLID PT. ELooKING. TO PROVIDE NAILING. FOR SACKER BOARD. lit- INSTALL REPLACEMENT BACKER BOARD 4 CE) VINYL SIDING (E) -W17. PANELING WINDOW JAMB CONTINUOUS SEALANT, TYp. SOLIDWOOD TRIM LID JAMB LINING SEALANT SHIM ASNECESSARY FILL GAP W/ BATT INSULATION UNDETERMINED VINYL SIDING SUBSTRATE CAREFULLY REMOYE TOP COURSES OF (E) VINYL SIDING AND BACKER BOARD FOR INSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE/ RE -INSTALL SIDING TO MATCH (E) (E) SACKER BOARD CE) VINYL SIDING BACKER RoD 4 SEALANT 3/4" WOOD SILL. In" ROUND WD. TRIM CONTINUOUS SEALANT, TYP. (E) WD. JAMB LINING SELF -ADHERING MEMBRANE CE) TILE (E)GW13 WINDOW SILL (3 00 VINYL SIDING - WINDOW DETAIL SET 3" = II - 0" REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 1 2013 • City of Tukwila BUILDING DIVISION RECEIVED CITY OF rwwitA 1JAN i0 7 2013 PERMIT CENTER S.MSTEMPER ARCHITECTS A Professional -Limited Liability Company 4000 DELRIDGF WAY SW SUITE 200 * SEATTLE, WA 98106 (20.5) 624-2777 • FAX (206) 624-2973 01.:MPTER • STATE 0810.03.2224 JUNE 7, 2012 0 Ct 0 UJ F— z 0 0 MPROVEMENTS >- 0 LU 2 Lu LU ce 0 ILL1 C7) 1.1.1 AIP NUMBER 3-53-0058-044 0 0 z DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2224 DOOM TYPES FLUSH SCW W/ WAGON WHEEL AND 4 PANELS LW SAFETY GLAZING.. W/ OBSERVATION PORT FLUSH 50111 1 LITE LW 2 PANELS IRI/ SAFETY GLAZING. G SECONDARY SLIDING GLASS POOR LW SAFETY GLAZING EXTERIOR SINGLE LEAF STOW lU/ SAFETY GLAZING DOOR SCHEDULE r;. DOOR NO ROOM LOCATION DOOR TYPE SIZE WxH FINISH INT./ EXT. HARDWARE ARE SET / FINISH KNOB / LEVER SE T LOCK SET DETAIL SET LIVING ROOM A 2'4" STAN/ STAIN HW -1 f 603 DK -4 LOCK -1 1/A2:0 2 KITCHEN (INTERIOR?`. B 2`-S" x ,6"-4" STAIN/ STAIN I4-2 / 603 DK -2 LOCK -2 2/A2.0 3 KITCHEN 5'_1I'r x STAIN/ STAIN 3/A2:0 TYPICAL DOOR SCH EDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT: NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE To BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT. SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2 SLIDING. GLASS DOORS SHALL MATCH THE OPERATION. OF THE. EXISTING SLIDING GLASS DOORS THEY REPLACE OR. COVER,. 3 FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH. HOMEOWNER PRIOR TO START OF WORK. 5 FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET. HEAD FLASH 3 1' - (}" LNG DETAIL TYP, (E) BACKER BOARD (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNDERL4TMENT' AND INSTALL, TOP EIDE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING.. LAP (E) WALL UNDERI.AYMENT OVER TOP OF SELF ADHERING FLASHING:. UNDETERMINED v'INYL SIDING SUBSTRATE (E) WALL UNPERLAYMENT SELF ADHERING MEMBRANE (E) EXTERIOR SHEATHING REMOVE (E) VINYL SID NG AS Kap FOR INSTALLATION OF WINDOW 4 -: FLASHING. REPLACE/ REINSTALL SIDING 4 ACCESSORIES To MATCH (E) VINYL J CHANNEL TRIM PRE -PRIMED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO SE SELECTED N THE FIELD CONTINUOUS SEALANT 3EHINP Z BAR FRAME STORM. DOOR PER SCHEDULE 2" MIN. (E) BACKER BOARD (E) VINYL SIDING TOUCH UP FAINT, AS IR1=Q'D CONTINUOUS SEALANT, TYP. SOLID IMOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION. WOOD FRAME: KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING. DOOR PER SCHEDULE` DOOR HEAD CAREFULLY LIFT CE) WALL UNDERLA'iMENT:. _. AND NSTALL:TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING LAP•OVER METAL'FLASHNO AN. EXTEND iiSELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E)< WALL UNDERLAVIENT' OVER. TOP OF SELF ADHERING FLASHING: REMOVE (E) VINYL SIDING AS REQ'D FOR. INSTALLATION a WINDOW t: FLASHING. REPLACE/ RE -INSTALL SIDING. 4 ACCESSORIES TO MATCH (E) VINYL J CHANNEL TRIM CONTINUOUS SEALANT BEHIND Z BAR: FRAME (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE TOUCH UP PAINT, AS REQ'0 CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SWIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING EATHERSTRIPPING DOOR PER SCHEDULE. DOOR JA MB HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2": MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR. STRUCTURE VINYL SI ,,. DING DOOR SILL. DOOR DETAIL SET SHIM AS NECESSARY FILL GAP W/ .BATT INSULATION BACKER ROD AND SEALANT SOLID WOAD TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING KEIF IN CONTINUOUS WEATHER STRIPPING SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING KEIRF IN CONTINUOUS WEATHER STRIPPING JAMB BEYOND Wo D DOOR PER SCHEDULE DOOR SHOE' AUTOMATIC DOOR SWEEP DOOR HEAD TOUCH UP PAINT,; AS •REQ'P CONTINUOUS SEALANT, TTP:. SOLID WOOD TRIM INTERIOR DOOR PER SCHEDULE • EXISTING FRAMING TOUCH UP PAINT, :AS REQ'D CONTINUOUS SEALANT, TTP. SOLID• Wc)OD TRIM 1 DOOR JAMB DOOR PER SCHEDULE DOOR SILL (E) EXTERIOR SHEATHING CONTINUOUS SEALANT 2X TAPERED CAP TRIM- PAINT TO MATCH (E) TRIM CONTINUOUS Zx SOLID BLOCKING AROUND PERIMETER: OF DOOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG"R INSTRUCTIONS TRIM- PAINT TO MATCH (E) TRIM CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF POOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS DOO R HEAD SOLID WOOD LINING (E) SLIDING GLASS DOOR DOOR JAMB SOLID WOOD LINING (E.) SLIDING GLASS DOOR b3O SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL- PER MFG'R INSTRUCTIONS: (E) SLIDING GLASS POOR (E) CONC. SLAB. OR (E) WD.. FLOOR FRAMING DOOR SIL L INTERIOR - SLIDING GLASS DOOR DETAIL SET 3" = 1' - 0" REVIEWED FOR CODE COMPLIANCE APPROVED JAN 11 2013 City of Tukwila BUILDING DIVISION RECEIVED oPrimmILA JAN 0 7 2013 S.M.STEMPER ARCHITECTS A Professional Limited' Liability. Company 4000 DDLEIDGE WAY SW SUITE 20.0 • SEATTLE, 11'A 98106 (206) 624-2777 • FAX (206) 624-2973 0810.03.2224 JUNE 7, 2.012 0 0 J z Q ui 0 O 0 H z Z W C/) Ci COc W LL 0 Ce C W MPROVEMENTS AIP NUMBER 3-53-0058-044 DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.2224 (E) SACKER BOARD (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNPERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TIP AT I -15.4D AND JAMBS. REMOVE (E) VINYL SIDING FOR INSTALLATION OF VENT FIXTURE AND FLASHING. REPLACE OR RE INSTALL SIDING AS REQ'D TO MATCH (E).SIDING. PRE -PRIMED, GALY SHEET METAL FLASHING (11/ F.F. END CAPS UNDER SURFACE MOUNTED REGLET AND CAP FLASHING. PAINT COLOR TO BE SELECTED IN THE FIELD SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLAYMENT SELF. AOHERINa, BITUMINOUS, MEMBRANE FLASHING (E) :EXTERIOR. SHEATHING' PAINT VENTILATION FIxTURE, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR kW ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. 2X BLOCKING 2X2 SLOCKNG, 4 SIDES (P.T) REPLACEMENT SIDING AS REQUIRED UNDETERMINED VINYL SIDING SUBSTRATE EXISTING ROOF VENT EXISTING ROOF STRUCTURE 2X BLOCKING AIR INTAKE DETAIL AT EXTERIOR 311 = 1' - 0" EXIST NG VENT COVER • I% CROSS SECTION EXISTING ROOF STRUCTURE NEW 2"X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 21X SPACER LATERAL SECTION II • MN. TYPICAL 'TOP 4, 15OrrOM,' NEW I". INSULATION !a0ARD., GLUM" TO NEW 3/4" EXTERIOR GRADE. PLYWOOD. ROOF VENT BAFFLE DETIAL 1 1/2" = II _0I1 EXISTING ROOF (E) ROOF FRAMING (E) EAvE VENT 151.011N N CELLULOSE INSULATION WITH A coMSINE VALUE OF NOT LESS THAN R-38 INSULATION DAM 2 INSULATION DAM DETAIL (E) WALL FRAMING FILING MOUNTING BRACI<ET 1411 X IV ANGLE IRON LEG BOLTED TO (E) STRUCTURE BLENDING AIR UNIT DETAIL 1 1/2" = 1' -.0" cEILING 4"MN ACCEPTABLE I4ERE NOTE: REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED: REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL. HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. SMO I SIOE WALL SUSPEND MECI4 UNIT FROM (E) .STR4CTURE .RE:. MECHANICAL MECH UNIT ANp, DUCTS - REF MECHANICAL r3--%‘00(9 KE DE ECTOR INSTALLATION DETAIL 3" = 1' - 0" REVIEWED FOR CODE COMPLIANCE APPROVED JAN 11 witi • City of Tukwila BUILDING DIVISION FECENICI env (Ir wv ore 1JAN 0.7 2441 S.MSTEMPER ARCHITECTS A Profesaional Limited Liability Company 4000 DELRIDGE WAY $W SUITE 200 SEATTLE, WA 98106 (208) 624-2777 • FAX (206) 624-2973 • V 0810.03.2224 JUNE 7, 2012 0 cLz'17C-I F- 0 0 I— Z Z CO LLQ 0 Z < zG C.) 0<o 0 L1.1 0 MPROVEMENTS AIP NUMBER 3-53-0058-044 DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML,&TF DRAWN LB&CP MISC. DETAILS A2.2 0810.03.2224 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD NOTE: REMOVE (E) SIDING BACK FIRCrt (E) RQ. AS MOD CE) SIDING NOT SHOLLN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLI-NG 14A5 DEEN INSTALLED LAP SILL MEMBRANE FLASHING 2-1/2" OVER (E) DLDG. PAPER AT SILL. EXTEND I i" BEYOND R.O. AT EA. END OF SILL. 614EATI4ING CUT SILL FLASHING 4 FOLD THROUGH RO. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL 614EATHING MIN El MEMBRA NE FLASHING. AT SILL BUTTERFLY CORNER FLASHING SCALE: LIFT (E) MPG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. CE) SIDING NOT SHOWN FOR CLARITY. NTS NOTE: REMOVE (E) SIDING SACK FROM (E) 'IRO. AS REQD (E) SIDING NOT SHOWN FOR CLARITY'. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAP AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE. EXCESS MATERIAL. po NOT SEAL FLANGE AT WINDOW SILL (E) DLDG. PAPER AT SILL. • ''';'ZT N• \\\ ELEVATION. VIEW NOTE: jNsTALL, LONpow.:FER1IFONO:.5PgalF10ATIO NOTIFY TacH1410,44. mm00417,4;14. OF DISCREPANCIES WINDOW MEMB RANE NSTALLATION MEMBR4NE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENNGS. SEND ANCHORAGE NAILS D01114 ;>. OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING REMOVED SCALE: EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY, (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS ft S NOTE: REMOVE (E) SIDING DAM FROM (E) RO. AS REQ'D CE) SIDING NOT 51401.1.N FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMDRANE FLASHING HAS BEEN INSTALLED. r -- WHERE REQUIRED, TRIM (E) ISLOG PAPER. AT HEAD TO PREPARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW. TRIM (FOLLOWING STEPS). HEAD FLASHING PREPARATION SCALE: NTS NOTE: REMOVE CE) SIDING SACK FROM (E) RO: AS. REO'D (E) SIDING NOT 51401114 FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. MEMBI3AN CUT JAMB FLASHING 4 FOLD AROUND WINDOW. OPENING AS. SHOIN. EXTEND i-vr BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING E FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS. RE0P (a) SIDING NOT 51401114 FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. INSTALL 614T. METAL. HEAD FLASHING LINDER (E) BLDG PAPER. - INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASI4ING. MEMBRANE FLASH) NG AT JAMB SCALE: NTS. NOTE: REMOVE (E) 'SIDING SACK FROM (E) R.O. AS REceo (E) SIDING NOT 514004 FOR CLARITY REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLAS1-ING HAS BEEN INSTALLED. ALLOW VS" l CLEARANCE: SETWEEN FILA514NG AND BOtIEDGE OF (E) SIDING. (E) SHOW DIAGRAMATICALLY. (E) SIDING NOT 514011.14 FOR CLARITY. HEAD F LASHING INSTALLATION SCALE: NTS CE) BLDG. 'PAPER MEMBRANE FLASH ING AT HEAD CUT HEAD FLASHING. 4 FOLD AROUND WINDOW OPENING AS 514011N. EXTEND 1-1a1 BEYOND RQ. AT NEAP AND JANOS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) SCALE:. NTS, NOTE: REMOVE (E) SIDING BACK FROM (E) W. AS REoP (E) SIDING NOT 514011.14 FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FI-ASHING HAS BEEN INSTALLED. INSTALL HEAD FLANGE FLASHING. OVER WINDOW NAILING FLANGE AND. FLASHING. I: 6: \.s..L.,) SCALE: N 0 WINDOW FLASHING J I INSTALLATION TS SHEET METAL HEAD FLASHING (E) STAN* WOOD T RIM INSTALLATION SCALE: NTS (E) EILDG. PAPER BENEATH spit,* INSTALL U. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDNG. APPLY SEALANT DEAD TO JOINT BETWEEN WINDOW •IM AND SIDING. LEAVE... 1/4"-3,18" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS "SELF AP44EARING: MEN :.RANE FLASHING" TYPICALLY REPERtr) TO AS "PEEL AND STICK' 2: DETAILS "L 2, AND 30 REFER TO MEME3RONE INSTALLATION PRIOR TO WINDOW INSTALLATION 3; DETAILS "5 AND 6" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS SEEN SET IN PLACE, SHIMMED, AND ANCI4ORED. 4: DETAILS "1 AND 5" •REFER TO SHEET METAL HEAD FLASHING. 5: DETAIL REFERS TO WOOD TRIM AND CAULK JOINTS. (3 0 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 1 7fin City of Tukwila BUILDING DIVISION RECEIVED cm, OF T1, lin4M,A JAN 0 7 2013 PERmiT Cergie.# S.MSTEMPER ARCHITECTS A Ptofeasional Limited Liability Company 4000 DELRIDG WAY SW •SUITE 200 SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 11J . . . JUNE 7, 2012 0810.03.2224 0 CL. Ce 0 z LU z z 0 0 0 AIR NUMBER MPROVEMENTS 3-53-0058-044 0 0 DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW FLASHING DE -TAILS A2.3 0810.03.2224 AlaBREVIA. .1QN$ LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTU H CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN M TG MFG NC NIC NFPA NG NO NTS OA OAT 00 OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR WB WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING. UNIT ABOVE FINISHED: CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR. -CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL: UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PERMINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN: DRAWING EXISTING EACH, EXHAUST AIR .ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL -STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE. FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY' INCH KILOWATT,: (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE. LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTEC11ON' ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION pOimps. PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE:: ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING, STATIC PRESSURE STATIC PRESSURE DROP' SPECIFICATIONS SEATTLE RESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT,. VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LI STED SYMBO ABBR OR XX 0 X/Y ////, DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO -BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GEN M2.0 MECHANICAL FLOOR PLANS E.RAL NOTES AND DRAWING INDEX MZ1 MECHANICAL FLOOR PLANS AND DETAILS GENERAL NIQTES 1. THg MECHANICAL iSYSTEM sHALL CONSIST of ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANSDIAGRAMS, DETAILS, ETC., AND ALL WORK As IDENTIFIED IN THE: .Bp-pliFtc•ATIpNB..: WORK INCLUDES FURNISHING, INSTALLING .SYSTEM INTEGRATION TEsTiNc,TRAINING AND WARRANTY OF THE. ;MECHANICAL SYSTEMS As SHOWN AND SPECIFIED. pRovipF. A: COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM ',OPERATION. 2, THE DESIGN OF MECHANICAL SYSTEMS HA, ; BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED-' BY THE MANUFACTURERS. LISTED ON THE EQUIPMENT SCHEDULE, EQUIPMENT NAMED IN THE SPECIFICATIONS. MAY BE :SUBSTITUTED PROVIDED THAT. THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND. HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES .AND GUARANTEE IN :WRITING THAT NO ADDITIONAL -COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION, 3,_CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS 'BEFORE 'BEGINNING coNsTRucTioN OR oRDERNG 'EQUIPMENT, ' DO NOT scALE. FROM PLANS.. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9 REQUI REMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 5. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 41-0" AFF. UNLESS NOTED OTHERWISE 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 10t-0' CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAM NG, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 31-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL XXX ABBR DIN I + et -1- DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT *lh VD RA/EA loio OR EQUIP NG - a 1. RG SA SA RA/EA SD FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDE/:LL SUPPLY AIR DUCT RETURN. MR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT .LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUI REMENT MECHANICAL ELECTRICAL COORD NATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURN SHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION 23 26 „ .23. ... 26 NfI 23 26 N/A REMARKS :BVI BLENDING UNIT VENTI LATOR 20 X X X 1,2 SWITCHES (ON. TIMER) x X :MOTOR OPE RATED DAMPER 24 X X 1,2. THERMOSTAT 24 X x REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BL ENDING UNIT VENTILATOR MARK. CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL WATTS VOLTS PHASE COMMENTS 115 .5" WG 32"Lx12. 25Wx8. 5"H 76. 120 I, 2, 3 NOTE: I. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF ,ALEYES- AMERICAN A, OR APPROVED EQUAL, GRILLE AND DIFFUSER SCHEDULE MARK CFM S'TATI C PRESSURE. INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS SGI 115 <.08" WG 7" 7" FLOOR 350 I, 2, 5, 6 90 <,:08" WG 6" WALL. WALL, CAP I, 2, 3, 4 RG -I 25 ‹.08" WG 4" 'FLOOR 35Q: 1, 2, 5, 6 REMARKS: I. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2 PAINT To BE COORD1NATED WITH TECHNICAL REPRESENTATIVE 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 4. BASIS OF DESIGN ALDES A. OR APPROVED EQUAL, 5. BASIS OF DESIGN: SHOEMAKER A. OR APPROVED EQUAL. 6: PROVIDE WITH AN OPPOSED BLADE DAMPER WA LL CAP SCHEDULE MARK LOCATION CF AIR VELOCITY FPM PRESSURE SIZE REMARKS WC4 EXTERIOR: 90 337 TO; 1,2 REMARKS: I. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN; FAMCC) HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE -CODE FLOOR AREA (SQ. FT.) NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2224 MOD 1311 3 90 CFM 90 CFM 0810.03,2224 BV -I 339 90 CFM 90 CFM 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51-51-1508, TABLES MI508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION vt IN VALUE NOTES ON ROOF DR ON EXTERIOR OF BUILDING R-8 WITH WEATHERPROOF BARRIER 1.3 ATTIC, GARAGE. CRAWL. SPACE, IN WALLS. IN FLOOR/CEILING R-8 1.2.3 WITHIN:CONDITIONED SPACE OR tN HEATED BASEMENTS R-8 1.3 IN CEMENT SLAB OR IN GROUND R-5 1.3 NOTES; I, THICKNESS OF INSULATION IS: .DERNED A$ THE THICKNESS OF THE EAsicj:NsuLAT.ING rv..EDufm NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY EE OMITTED ON THAT PORTION OF'.A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE **HERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED- TO CONDITIONED AIR. 3. REFER TO WASHINGTON TATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. IH DRAWING .NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 011101 AND 028200 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. ERMOSTAT/SWITCH HOURS OF OPERATION SET FURNACE THERMOSTAT/SWITCH TO OPERATE: 1 OF EVERY 2 HOURS. SET 8V-1 SWITCH TO OPERATE 1 OF EVERY 3 HOURS. • FURNACE MECHANICAL VENTILATION CALCULATION PER WAC 51-51 M1508.3: OF = QR (&ECR X F) QR =. (FROM TABLE M1508.2) 4 &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1/2) = 90 CFM BV -1 MECHANICAL VENTILATION CALCULATION PER WAC 51-51 M15083 QF = QR / (&EGR X F) QR = (FROM TABLE m15o6.2) &EGR - VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION la QF = 30 / (1 x1/) = 90 CFM b13-- o SEPARATE PERmir AND APPROVAL REQUIRED RECEIVED CITV OF TUMARA I JAN tO 7 2013 PERMIT CENTEP EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Protean:1one Limited 11416114 Compway 4000. DELRIDGE WAY SW SUITE 200 SEATTLE, Wit mos (206) 624-2777 • PAY (200) 624-2078 THE GREENBUSCH GROUP, INC ) ) 46404011.44) /11111111CAL, AU010 / 141303 k NECHVICAL ENO001G 1000 107 imcM saw SUITE 201 SEM VIA 0110 (200) 378-0569 (206) 370-0041 FAX MPROVEMENTS RESIDENTIAL A AIP NUMBER 3-53-0058-044 DATE 06/05/2012 ISSUED 100% CO. PROJECT ENGINEER 00 PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M .0 0810.03.2224 DRAWING:NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51, SECTION M1508.5.4. 3. SEE ELECTRICAL DOCUMENTS FOR. FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION„: THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 :HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51,..51,„ SECTION M1508.5.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE 'vENTILATioN SYSTEM wallow- ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES), COORDINATE FINAL TIME SETTINGWITH PROJECT REPRESENTATIVE. 4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. 90 FLAG ..NOTES;._ CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE WSEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO .THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51, SECTION. M1508.5.2. COORDINATE FINAL SWITCH LOCATION WITH HOMEOWNER. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.O. EN -1 AND DUCTWORK ROUTED IN STORAGE SPACE. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL 'REPRESENTATIVE. LOWER FLOOR SCALE: 1/4" = 11-0" 5TOAGE NtEcHANICA...-, PLAN NORTH HOLD DUCTS TIGHT TO JOISTS lb' EXIST. ATTIC .ACCESS PANEL MA I N FLOOR MECHANICAL PLAN SCALE: 1/4" = 1* -0* 441111NORTH SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED CITY OF TUKWILA I JAN ,0 7 2013 PERMIT CENTW EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Prote0010631 Maned Liabilit9. Cenvatny 4000 DELRIDGE WAY SW SITE 2QO SMITLE, WA 08100 206) 624-2177 ^ 1AX (206) 62071673 THE. GREENBUSCH GROUP, INIC 0 66 *666j Ii 0 16211.111CAL DIONEERINO TOrS iell"IVIEAU1112011322141° 101V11 1 011E 201 92222, 00110 206) 312-0569 (206) 378-0844 FAX 0810.03.2224 0 1:e 0 w ce 0 0 0 IMPROVEMENTS FT NOOSE REMED RESIDENTIAL AIR AIP NUMBER 3-53-0058-044 PATE 06105/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO PRAWN JA, DT MECHANICAL FLOOR PLANS M2.0 0810.03.2224 FLAG NOTES: FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51-51, SECTION M1508.5.1. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE/RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51, SECTION M1508.6.4, TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. 4T0 Ei V-1 25 KI TCHEN 2 SG -1 115 ATTIC IS' x IV EXIST, ATTIC AC4ESS PANEL MECHANICAL PLAN SCALE: 1/4 = 111-0" eNORTH >- OE a- Lti lx -U IX Li FURNACE CEILING OUTSIDE AIR DUCT, SIZE AND ROUTE IN JOIST PER PLAN VOLUME DAMPER FOR EXISTING RETURN DUCT, RELD VERIFY SIZE PRIOR TO ORDERING MOD, INTERLOCK TO FURNACE FLUE. POC FLOOR: FURNACE ELEVATION SCALE: NONE SHEETMETAL TRANSITION TO WALL CAP NECK SIZE DUCT PER PLAN CAULK 2X BLOCKING 2X BLOCK!. G FOAM BACKER ROD WALL CAP SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL PER. MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORD. W/ARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1/A2.2 FOR DETAIL P DETAIL OUTSIDE AIR DUCT RETURN AIR DUCT MOD By -1 HOLD TIGHT TO STRUCTURE SUPPLY AIR DUCT NOTES: MOTOR ACCESS FILTERS ACCESS 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. VERIFY UNIT ORIENTATION. BEFORE INSTALLATION.. 3. INSULATE ALL DUCT AS SCHEDULED. BV -1 INSTALLATION DETAIL SCALE: NONE SLEEVE AND ESCUTCHEON 2X BLOCKING CAULK SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT, ROUTE PER PLAN FLOOR GRI FLOOR: LLE 2X BLOCKING. FOAM BACKER ROD 0 kb13---oo(ar NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.. 2.: SEE PLANS FOR VOLUME DAMPER LOCATIONS. RECEIVED CITY OF TUKWILA JAN 0 7 2013 MIT CeiNr, 0 FLOOR GRILLE DETAIL SCALE: NONE SEPARATE PERMIT AND APPROVAL REQUIRED EXPIRES; 9/08/2012 STEMPER ARCHITECTS A Frofeawimal Waited Liabiliky Ctmapow 4000 DELRIDGE WAY SW SUM 200 SEATITS, wit 08108 (200) 024-2777 ^ PAX (200) 024-2272 THE GREENBUSCH GROUP, INC AO0t1S2244 AIJC40 J vm� & MECHNICAL 10101WERINO 1000 WV WOMN STREET' KR 20 SWIM WA 11010 (200 370-0500 (200) 3700041 FAX re 0 CL re 7C -C 0 w. re z z 0 0 0 MPROVEMENTS FT NOISE REMEDY RESIDENTIAL AIR AlP NUMBER 3-53-0058-044 DATE 06/05/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN „IA, DT MECHANICAL FLOOR PLANS AND DETAILS M2.1 0810.03.2224 E ECTRICAL - PROJEC NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3, MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDIIIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL.. ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NO ES ,PROVIDE: COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT, COORDINATE WORK WITH MECHANICAL DRAWINGs, PROVIDE TIMER SWITCH AND COMPLETE CONNEC11ONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. , • DEMO EXISTING PANEL. USE As JUNCTION BOX, EXTEND EXISTING: CIRCUITS TO NEW PANEL NEW PANE IMPL,. SEE DETAIL AND PANEL SCHEDULE eNORTH EF;JR0 1 CL 05E T lan 18." EXIST. 4TTIC ACCESS T. TO PLIMIACE GOMM T 1 c14 -21\I BED ELECTRICAL LEGEND 5111E01, - DESCRIPTION SYtit01- DSCRIPTION LIGHTING OR POWER PANEL Ilif 0 BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR ocrs DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2*C. MIN. EMT OR RIGID STEEL INDICATES EQUIP GNI INDICATES ISOLATED GROUND. MAST, WEA1HERHEAD BRANCH CIRCUIT HOME RUN. D E3' EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. DAMPER CONNECTION NON-FUSED DISCONNECT SWITCH TOGGLE TYPE MOTOR DISCONNECT SWITCH Will THERMAL OVERLOADS SMOKE IDEICTOR [al ELECTRICAL MEIER TIMER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE WITH UIILITY. CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT NEW PANEL. SEE DETAIL AND PANEL SCHEDULE THERMOSTAT UNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR MECHANICAL / ELECTRICAL COO !NATION EQUIPMENT NO. CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVES ON 15 16 15 16 N/A 15 16. N/A REMARKS BV -1 BLENDING UNIT VENTILATOR 120 1 X X 1,2 SWITCHES (ON, TIMOR) 1 0 1 X X X DEMO EXISTING PANEL USE AS JUNCTION BOX. INTERCEPT AND EXTEND EXISTING CIRCUITS TO NEW PANEL CLO6ET lp I NI:NCI: fROON f3E r-.) ROOM METER AND FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY CHARGES IN BID. PROVIDE NEW METER BASE, RIGID STEEL MAST, WEATHER HEAD AND CONDUCTOR PIGTAILS PER SCL REQUIREMENTS. FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY SERVICE FEES IN BID. PROVIDE NEW WEATHER HEAD, MAST GUYS AND /— ANCHORS AT EXISTING LOCAllON. PROVIDE NEW ROOF FLASHING. ,,,PROVIDE MINIMUM 36w CLEARANCE AROUND SERVICE WIRES PER SCL REQUIREMENTS. MOTOR OPERATED DAMPER THERMOSTAT REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH 4 1 X 24 11 X• X X L LI X 1,2 1 t Ii– — • • .., 1 r, L_ sEpAR„, PemiiiAct REQUAPPRovAL IRED RECEIVED env OF TUWW111 I JAN .0 7 2013 PERMITCEnnfr S.MSTEMPER ARCHITECTS A Profesahmal limited Liability Company 4000 DELRIDGE WAY SW SUITE 20Q. SEATTLE, WA 9810Q (206) 624-2777 • FX (206) 624-2973 INSINUURS.INO 11911 MTN MO ORM 61111111120 %Weft "A ONSMIS Trumps Ole wit fale 40 ass 0810.03.2224 NTERNATIONAL AIRPORT z 0 0 AIP NUMBER. MPROVEMENTS F - Cl) w 5-53-0058-044 DATE JUNE 7, 2012 ISSUED 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES El .° 0810.03.2224 PANELMP • ......... „ . LOCATION. SE-RANG.,iiiaaHIDENC,EH 10,000 120/240 VOLT, 1 PHASE, 3 ME. 200 AMP with. MAR BIM CKT LOAD DESCRIPTION TYPE KVA AP. PHASE KVA TYPE LOAD DESCRIPTION CKT 1 EXISTING LO 20/2 14 I .001.7rINGILOAta. • . 17 EXISTING LOAD 19 ExAmt_pAp_ 21 EXISTING LOAD 23 EXISTING LOAD 30/1 20172 itht: 1511 1511 4511,, 15/1 154 2011 23„ EAST N G LOAD 27 29 .... 31. 30 35 . . EXISTING37 LOAD EXISTING LOAD A Et, 0012 20/1 B A A 15/1 EXISTING LOAD 2 4 PROVISION PROVISION PROVISION PROVISION 8 10 12 20 22 24 A 41 a A B A 28 30 32 34 36 38 : . PHASE LOAD PHASEPHASE 0*-: Vi A K LM TOTAL LOADS CONN, LOAD ... KVA AMP COMPUTED LOAD AMP ISOLATED GROUND RAINTIGHTNEMA-3R FEED THR&J WOS [j MAIN BKR SHUNT TRIP PANEL SKIRTS SURFACE ....... DOUBLE LUGS SERVICE ENTRANCE ',1!:S.FTE•PRWTV.5asi', []FLUSH . REMARKS. PAN EL LOCATION ••••••••• •••••••••••••••••vr....------- ENC . •'• '•• • 120/240:VOLT. I PHASE, L_WHE • • loxo:A10, - , .::,... . . •LOAD DESCRI PT1ON ..P• ..:PHASE ... KVA. L6AO.DESCRIPTLOf-,1 .. . . CKT 1 EXISTINGLOAD !i!! .3.. 3 30/1 .EXISTING LOAD " !!..Js 9 EXISTING LOAD 20/1 11. t40wyPe: • CONN. LOAD COMPUTED LOAD. ..... , ..... .. . A ISOLATED GROUND ENCLOSUREDOUBLE LUGS P.501(14$.41tiEl . 2011 EXISTING LOAD EXISTING LoAal EXISTING LOAD ... . L..> • • : susiDING UNIT ... .„. • ••• lAIN SKR SHUNT TRip SERVICE etilAMOt080% 2 4 a,•- 12 KVA AMP PANEL SKIRTS DiSURFAZ't .. .. , ..... . ... ... , NTOOlikTAM$ FLUSH RE .. . ••••:,] .. , ..• PROVIDE NEW RIGID STEEL MAST, WEATHER HEAD AND CONDUCTOR PIGTAILS PER SCL REQUIREMENTS. FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY SERVICE FEES IN BID. PROVIDE NEW MAST GUYS AND ANCHORS PROVIDE METER BASE. PER SCL STANDARD pu13-44/NPAT-30 ROOF z g Um U. S.4 PROVIDE #4CU GROUNDING ELECTRODE CONDUCTOR AND GROUND RODS PER CODE. MAX 10 OHMS TO GROUND re, 3#3/0 CU METER AND FINAL. CONNECTIONS BY SCL. I NCWDE ALL UTILITY CHARGES IN BID. 3#3/O CU.& GND PROVIDE NEW NEMA --3R S.E. RATED PANEL BOARD. INTERCEPT AND EXTEND EXISTING CIRCUITS AND CONNECT TO NEW BREAKERS. PANEL Nip 200A 120/240. 1—PH, 3W -PROVIDE NEW SERVICE \ DROP FROM POLE TO I, HOUSE BY SQL. ALL FEES PAID BY CONTRACTOR. 1-1/4"C, 3#6 1#10G. PROVIDE ALL REQUIRED CUTTING .AND: PATCHING. AS REQUIRED TO COMPLETE THE WORK AS DESCRIBED ABOVE AND ON DRAWINGS. ROUTE CONDUIT EXPOSED ON OUTSIDE OF HOUSE. PROVIDE STRUCTURAL SOLID 2X6 BLOCKING IN ATTIC FOR MAST. PROVIDE BLOCKING AND UNISTRUT ASSEMBLIES TO HOLD CONDUIT AWAY FROM HOUSE SURFACE TO ALLOW FOR EXISTING CONDITIONS. VISIT THE SITE TO ESTABLISH EXACT CONDITIONS PRIOR TO BID. PANEL MP1 60A 120/240 1—PH. 3W t3N- 00 b SEPARATE PERMIT AND APPROVAL REQUIRED RECENED MP OF Tl MAMA I JAN 0 7 2013 -frimot SeMSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRID GE WAY SW Sian 200 • ST ATTU , WA 98106 (208) 624-2777 • FAX (206) 624-2973 INOININNO. INO ma MAN MD *111111% gum isso 1114:0s.014 Irturititea IMAM NW MN 4111 *WM 0810.03.2224 0 0 Ce 0 j IY U -I 0 LL 0 0 —•=- 0 w (.9 Z MPROVEMENTS AIP NUMBER 5-53-0058-044 SEATTLE WASHINGTON DATE JUNE 7, 2012 ISSUED 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR.. DRAWN JAB FLOOR PLANS NOTES El 1 0810.03.2224