Loading...
HomeMy WebLinkAboutPermit D13-008 - CARTER RESIDENCE - REMODELCARTER RESIDENCE 11802 40 PL S D13-008 City *Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 7340600083 Address: 11802 40 PL S TUKW Suite No: Project Name: CARTER RESIDENCE DEVELOPMENT PERMIT Permit Number: D13-008 Issue Date: 01/15/2013 Permit Expires On: 07/14/2013 Owner: Name: CARTER LARRY M Address: 7428 LATONA NE , SEATTLE WA 98115 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: G & G SPECIALTY CONTRCTORS INC Address: 4633 S 36 ST , PHOENIX AZ 85040 Contractor License No: GGSPEGS919RT Lender: Name: Address: Phone: 206 296-7437 Phone: 480-921-4079 Expiration Date: 12/31/2013 DESCRIPTION OF WORK: RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE - WORK TO POTENTIALLY INCLUDE SELECTIVE REPLACEMENT OF WINDOWS, SELECTIVE REPLACEMENT OF INTERIOR/EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS, INSTALLATION OF SECONDARY SLIDING GLASS DOORS AND SKYLIGHTS, ETC. Value of Construction: $30,978.00 Fees Collected: $1,116.68 Type of Fire Protection: International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT **continued on next page** doc: IBC -7/10 D13-008 Printed: 01-15-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non -Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: _ A ► 1 J . v . Date: (9-t\ Ic\ I� I hereby certify that I have read and - yLi�i ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance kf, k. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permi , Signature: Print Name: I) C 1 Date: 1-65=13 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D13-008 Printed: 01-15-2013 this requirement. 'r • 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D13-008 Printed: 01-15-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Building Permit No. `-- Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 7340600083 Site Address: 11802 40th PI. S. Tenant Name: Larry Carter Suite Number: Property Owners Name: Larry Carter Floor: New Tenant: 0 Yes ..No Mailing Address: 7428 Latona Ave. NE Seattle WA 98115 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296-7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker@kingcounty.gov City State Fax Number: (206) 269-7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: Zip Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: City Day Telephone: Fax Number: State ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody@smstemper.com or tim@smstemper.com City State Day Telephone: (206) 624-2777 Fax Number: (206) 624-2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H: Appltcations\Fonns-Applications On Line 2009 Apphcanons\I-2009 - Permit Appltcanon.doc Revised: 1-2009 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT INFORMATION - 206-431-3670 Valuation of Project (contractor's bid price): $ ‘257472-9)0/4111 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes m No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm m None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\2009 Applications \I-2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 1,136 2"d Floor 3`d Floor Floors thru Basement 1,136 Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes m No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm m None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\2009 Applications \I-2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. !^ BUILDING OWN • I R A %/:/" ED AGENT: Signature. Print Name: "mothy . Fenlason, SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 L., Date: 7/13 Day Telephone: (206) 624-2777 Seattle WA 98106 City State Zip Date Application Accepted: o' V � 1 ` 27 Date Application Expires: 01 01 1 01 I 13 J 3 Staff Initial :�,/�I H:\Applrcanons\Forms-Applications On Ltne\2009 Applicanons\1-2009 - Perm¢ Applicanon.doc Revised: 1-2009 bh Page 6 of 6 • •/ PLUMBING AND GAS PIPING PERMIT INFORMATION — 206-431-3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please providdetailed information): Building Use (per Int'l Building Cod! Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gasAjping outlets be' : installed and the quantity below: Fixture Type: Qty Fixture Type: a ty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain o • water cooler (per ad) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Wate . eater and/or vent Industrial waste treatment interceptor, including trap d vent, except for kitchen s ‘e grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen (>750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Re it or alteration of drai ;e or vent piping Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow . etective device other than at .' spheric -type vacuum break: , over 2 inch (51 mm) di.. I eter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric-ty e vacuum breakers not i • ded in lawn sprinkl: .ackflow protections -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets F H:\Applications\Forms-Apphcanons On-Lme\2009 Apphcanons\1-2009 Permit Application.doc Revised: 1-2009 bh Page 5 of 6 City a fukwilar Department of Community Development 6300 Southcerter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: ht4v:/www.ci.tulnvila.wa.us SET RECEIPT • RECEIPT NO: R13-00124 Initials: JEM Payment Date: 01/09/2013 User ID: 1165 Total Payment: 13,045.45 Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE) SET ID: S000001897 SET NAME: KING COUNTY NOISE ABATEMENT SET TRANSACTIONS: Set Member Amount D13-004 1,018.34 D13-005 1,239.61 D13-006 1,313.36 D13-007 779.67 D13-008 1,116.68 D13-009 1,141.27 D13-010 1,313.36 D13-011 1,092.10 D13-012 1,239.61 D13-013 1,092.10 M13-003 167.70 M13-004 186.50 M13-005 177.10 M13-006 167.70 M13-007 177.10 M13-008 177.10 M13-009 124.25 M13-010 177.10 M13-011 167.70 M13-012 177.10 TOTAL: .i;918 — _ Int 0140 14C TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 13,045.45 TOTAL: 13, 045.45 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES 000.322.100 6,849.15 City ukwilar Department of Community Development 6300 Southcenter Boulevard, Suite 4100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http:/Svww.ci.tukwila iva us STATE BUILDING SURCHARGE 640.237.114 45.00 TOTAL: 13, 045.45 1 '3 -dam INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 'm (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project; C� Type -of rf f Address: I ( 0 z -rt. o �pL--. Date C I d: 6-t ?.., Special Instructions: /0 Wanted:3 Date 2 - -1 --5 a.m. irg- Requester: Phone No: t/, cp --S—f4 ---O r4 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS:r cid-". TAS.,) � %�; J n — ( ,, i, 61.• (3. A Inspector: Date �ZS� 3 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Jennifer Marshall From: Sent: To: Cc: Subject: Tim Fenlason <tfenlason@jonespayne.com> Tuesday, January 08, 2013 11:29 AM Jennifer Marshall sharyn.parker@kingcounty.gov; Jesse Holgate Re: KCIA RANRIP Submittal You are correct. I'd like you to change the applications to reflect the amounts in the pink column. I thank you for this extra work and if you'd like, I can gladly drive to your office to make the changes. On Tue, Jan 8, 2013 at 9:56 AM, Jennifer Marshall <Jennifer.Marshall@,tukwilawa.gov> wrote: Good morning Tim, Due to the fact that I cannot just arbitrarily change information on permit applications, I am clarifying the direction you are giving me. Are you directing me to update the valuations provided on the applications submitted yesterday to the numbers below under the column highlighted pink and labeled "Value Originally Provided?" Applicant Name Ochoa Residence Nguyen Residence Aragon Residence Aragon Residence Carter Residence Christensen Residence Fasano Residence Kerr Residence Nguyen/Diem Residence Rivera Residence Address 1186344Av S 5016 Wallace St 4610 S 124 St 12245 46 Av S 11802 40 PI S 12212 48 Av S 12029 44 Av S 3834 S 116 St 11620 40 Av S 11826 44 P1 S Dev Permit Value Provided on No Application D13-004 $24,018.00 D13-005 D13-006 D13-007 D13-008 D13-009 D13-010 D13-011 D13-012 D13-013 $31,135.00 $32,099.00 $17,201.00 $25,472.00 $28,169.00 $37,403.00 $23,133.00 $33,129.00 $23,619.00 Value Originally Provided $35,359.00. $38,407.00 $19;973.00 $30,978.00 $31,174.00 $38,918.00 $29;764.00 $35,722.00 $29,761.00 If these numbers are correct please respond accordingly and I place a copy of these emails in the file proving that I have been authorized to make the changes. If they are not correct, please provide me with the correction valuations. Thank you, Jennifer Marshall Permit Technician Original Message From: Tim Fenlason [mailto:tfenlason@jonespayne.coml Sent: Monday, January 07, 2013 4:18 PM 1 To: Jennifer Marshall Cc: sharyn.parker@kingcounty.gov; Bill Rambo; Jesse Holgate Subject: Re: KCIA RANRIP Submittal Jennifer, My preference would be to use the amount provided to Bill and to update the applications. I know that the amounts provided to Bill are correct, as I did those calculations myself. On Mon, Jan 7, 2013 at 4:08 PM, Jennifer Marshall <Jennifer.Marshall@tukwilawa.gov> wrote: > Good afternoon Tim, > I received the applications and plans for ten lots for the above > referenced project. I have completed the data entry in our permit > system and discovered there are discrepancies with valuations provided > to Bill Rambo and the valuations provided on the applications. I have > attached a spreadsheet showing those discrepancies. The issue with > there being a difference is that the permit estimate provided from > Bill is no longer applicable. > It is the end of my work day, so I will wrap this up tomorrow morning > (I probably will not be able to fit it in until about 10 am) and > provide the updated permit fees which will correspond with the new > valuations given. At that point we will need payment to be made > before the permits can begin the review process. I have also attached > the original worksheet you and Bill were working with for your reference. > Have a good evening. > Jennifer Marshall > Permit Technician, City of Tukwila > T: 206 431-3670, F: 206 431-3665 > jennifer.marshall@tukwilawa.gov Tim Fenlason Associate AIA Senior Job Captain 2 -�ERI�Ii COORD COP'S PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-008 DATE: 01/07/12 PROJECT NAME: CARTER RESIDENCE SITE ADDRESS: 11802 40 PL S X Original Plan Submittal Response to Correction Letter #_ Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Building 4ivision Public Works ❑ Fire Prevention 111 Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 01/10/13 Complete 16 Incomplete ❑ Not Applicable El Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route ,I Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/07/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Printer Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type G & G SPECIALTY CONTRCTORS INC 4809214079 4633 S 36Th Street Phoenix AZ 85040 Out Of State Corporation Parent Company G e G SPECIALTY CONTRCTORS INC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602975812 Active GGSPEGS919RT Construction Contractor 12/31/2009 12/31/2013 General Unused Business Owner Information Name Role Effective Date Expiration Date GOODBALLET, CHARLES ELMER Chief Executive Officer 12/28/2009 Bond Amount WAVY, CHRISTINE Chief Operating Officer 12/28/2009 59BSBEA9058 GOODBALLET, JAMES SCOTT President 12/28/2009 GOODBALLET, TERESA LYNN Secretary 12/28/2009 INS CO OF THE WEST Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 HARTFORD FIRE INS CO 59BSBEA9058 12/18/2010 Until Cancelled $12,000.00 01/03/2011 1 INS CO OF THE WEST 2278440 12/18/2009 Until Cancelled $12,000.00 12/28/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 Companion Property & Cas InsC PCP10000270101 11/03/2012 11/03/2013 $1,000,000.00 11/16/2012 3 National Union Fire Ins of PA PCP1000027 11/03/2011 11/03/2012 $1,000,000.00 12/27/2011 2 LEXINGTON INS CO 4392611702 12/31/2010 12/31/2011 $1,000,000.0001/11/2011 1 LEXINGTON INS CO 4392611701 12/31/2008 12/31/2010 $1,000,000.0001/14/2010 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 01/15/2013 KI NG CO U N TY I NT ERNAT ONA L ... . ..AIRPORT . ... . RESI DENTIALAIRCRAFT NOISE REMEDY IM PROVEMENTS PROGRA SCOPE OF WORK RENOvATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE 11ECI-1ANICAL vENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND SPECIFICATIONS INCLUDI14 BUT NOT LIMITED TO: APPLICABLE YES NO 1. SELECTIVE REPLACEMENT CF EXISTING WINDOWS WITH NEW VINYL-FRAMEDACOLISTICAL WINDOWS. 2. CUT POW OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. 3. INFILL OF EXISTING -OPENINGS, x. 4. SELECTIvE REPLACEMENT OF INTERIM / EXTERIOR DOORS WITH NEW ACOUSTICAL PoORS. 5. INSTALLATION OF STOW DOORS. 6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS. 1. INSTALLATION OF SECONDARY SKYLIGHTS. EX INSTALLATION OF PET DOORS. S. INSTALLATION OF FIREPLACE FRESH AIR vENT. 10. INSTALLATION OF CI-IItINEY CAP. 11. REGULATED MATERIALS ABATEMENT. 12 ATTIC VENT BAFFLES. X 13. INSTALLATION OF ATTIC INSULATION. 4. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, 8LENID1G AIR UNIT AND ASSOCIAMI, DUCTING. 15. INSTALLATION OF MECHANICAL vENTILATION. EQUIPMENT, FURIACE MODIFICATION AND ASSOCIATED DUCTING. 16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. x. 11. ELECTRICAL MODIFICATIONS TO SUPPORT ARCHITECTURAL MODIFICATIONS. NSTALLATION OF MECHANICAL VENTILATION AND 18. INSTALLATION OF SMOKE DETECTORS. IS. NEW ELECTRICAL PANEL / SE VICE 20„. KNOB AND TUEE SEPARATE PERMIT REQUIRED FOR: Iirmebhargad ErElectrical 261umbing teras Piping C7,17 of Tukwila puNNG DIVISOR. FILE COPY Permft No. phtl nein approval is subject to errors and omissions, of construction documents does not authorize ct any adopted code or ordinance. Receipt Co Isacknowledged: By Date: City Of ildcwila BUILDING DIVISION ‘16. i wbe made to the scope 07 c; J way include additional plan review fes. 1 REVISIONS No changes shall wOricwithout prior approval of 777: 1,.., jviu!0,anAitlilavviBi 1 ureilcidulinregaDnivewisipoinansubmittal B. M C00747C12 BI D. PACKAGE M-33 • 3-53-0058-044 SITE AND BUILDING I NFORMATION JURISDICTION: Department of' Planning and Development City of Seattle, UJA FPLICABLE CODES: 2005 International Residential Code, International Fire Code, International Mechanical Code 1340600083 ZONING: 8F1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) V B NON SPRINKLERED LEGAL DESCRIPTION: THE SOUTH 14ALF OF THE EAST 14A1 -P OF LOT(S), RIVERSIDE INTERURBAN TRACTS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 10 OF PLATS, PAGE(S) 14, IN KING COUNTY, WASHINGTON, LESS COUNTY ROAD. SITUATE IN THE CITY OF TUKWILA COUNTY OF KING, STATE OF WASHINGTON. DRAWING INDEX.. T0.0 TITLE SHEET, PROJECT INFO, 41.0 FLOOR PLANS 4 NOTES A2.0 WINDOW TYPES, SCI-EDULE 4 DETAILS A2.1 DOOR TYPES, SCHEDULE 4 DETAILS A22 MISCELLANEOUS DETAILS A2.3 WINDOW FLASHING DETAILS 111.0 LEGENDS, SCHEDULES, ABI5REV, GENERAL NOTES 4 DWG INDEX M2.0 MECI4ANICAL PLANS AND DETAILS M2.1 MECHANICAL DETAILS EliP ELECTRICAL FLOOR PLANS AND NOTES EU ELECTRICAL FLOOR PLANS AND NOTES "'•:. -••••• PROJECT DIRECTORY KING COUNTY INTL. AIRPORT; Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98.108 Fh; 206. 263. 9233 Fax: 206. 296. 0150 Contacti'Sharyn Parker E-mail: SharyriParkerekIngcounty.gov ARCHITECT: SM. -Stomper Architects 4000 Deleidge Way SW, Suite 200 Seattle, WA 98106 Ph: 206 624. 2111 Fax: .206. 624. 2913 Contact: Jerry .Osborn, 'Melody Leung, Tim Fenlason, E-mail; jerry.smatempe3r.com melodyosmstemperzotn timasmstemper.com ACOUSTICAL ENGINEER; SSA Acoustics 222 Etruria Stroart, Suite 100 Seattle WA 98109 Ph: 206. 839. 0819 Fax: 206. 959 0824 Contact: Mohamed Alt Allaoua inohainediassaadotistIcceisti MECHANICAL - 'WEER The GreenPusch':droup 1900 Weet Nickeittaoh St., Suite 201 Seattle, WA 98119` P1,: 206.318, 056.9 Fax; 206. 318. 0641 Contact: Dylan Turner E-mail: PulanTegreenbusch.com ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 95409 Ph; 253. 412. 3300 Fax: 203. 412. 3463 Contact: Brent Rollins E-mail: berstreswest.com REGULATED MATERIALS: 935 Engineering and Enviromental 2511 Eastlake Ave. E, Suite 100 Seattle, WA, 9802 ich: 206. 232. 9639 Fax 206. 162. 4180 Contact: Tim Ogden E-mail tim ogdensplcsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. 0200 Boston, MA 02114 Contact: Tim Fenlason, Cynthia Maeda E-mail: Via eda ejonespa yriacom STRUCTURAL ENGINEER:. Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 55121 Ph: 206.622.450 Fax; 206, 622, 0422 Contact: Ron Martinson rorin.psm-eneineers4om VICINITY MAP (NTS) REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 1 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA IAN 07 2013 PERMIT CENTER NORTH S.M STEMPER ARCHITECTS A. Professional Limited Liability Company 4000 Dp.REDGE WAY SW SUITE 200 • SEATTLE, WA 96106 (206) 624-2777 • PAX (206) 624-2973 10i) •A(:.-irrEaf • • 'A''.1•1•• OF, • • 0810.03.2226 JUNE 7, 2012 0 ce z 0 z z z 0 0 0z MPROVEMENTS z. 0 C/) AIP NUMBER 3-53-0058-044 DATE JUNE 7,2012 ISSUED 100% CD PROJECT ARCHITECT Jo PROJECT MANAGER IVIL&TF DRAWN LB&CP PROJECT INFORMATION, DRAWING INDEX, DIRECTORY TO.0 0810.032226 0 UNP IN I SHIED. !:BASEMENT SPECIAL NOTES: NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE: THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO WAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE. CONTRACTOR SHALL IDENTIFY, QUANTIFY, MD LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01 1101 AND 02 82 00 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE: REFER TO SECTION 01,1101 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. NOTE:. KNOB AND TUBE WIRING PRESENT.. STUDY LOWER FLOOR PLAN 114" = 1' r�a:::ssnus22srsss«•,• � aussssacssz�ss<sssst<;:<«:,f<yos�c�,:: 22" x 48" EXIST. ATTIC ACCESS PANEL 16" x 22" EXIST. ATTIC ACCESS PANEL INING ROOM NORTH PRIOR TO COMMENCING WITH DEMOLITION A "pre -demo inspection" is required. Contractors shall provide documentation that an "asbestos survey" has been completed. If needed, abatement procedures per "Puget Sound Clean Air Agency" shall be completed and documentation of compliance shall be provided at time of final inspection. MAIN FLOOR PLAN = 1' 0 1(W' minim l uiuinim �� I1 I1I/','1 11 a.I..1:...1 i II r1=-11 I IIS II 11 1.I f �,�..... jt ...\\` f( I. .i. I I 4 1.`.'. '.x'`16." x 2x! fXt$Tfj� ._;'.:� .:f > ... , , E 1 L P4 NEL 1. I 1----17.-=4„..T .......... (. ,-_.. / 1 .�I .'•'....................:•.•.••-.'•.•1...�_.. tI �r W 1 1 � II ...-1-1T-'-'-'---.-21..1 r 111, ��, . .� i ... . r ,. L._ L_ 17'-'I" 111111111111 11111111111 0 111111111111 ,1131111111 L J13'-3" A. EAST ELEVATION GENERAL NOTES 1. CONTRACTOR TO PROTECT °LINERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS ANP FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OP WORK DAILY 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN TWE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 15 ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME' DAY BETWEEN 8:00 AM AND 5:00 PM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS UI-IERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD Rt, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 9. EXISTING WINDOW COVERINGS MUST HE REINSTALLED ON THE SAME DAY A$ COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.. 10. INSTALL SAFETY GLAZING PER COPE. SEE WINDOW TYPE SCHEDULE:: 11. ALL U)0I ( AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH: WORK DAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE' WITH (E) CLOSET SHELVING, DEMO (E) 514ELVING AS 1;6111D AND RE -CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENT& RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTNG. RECONSTRUCT SHELVING 50 AS NOT TO INTERFERE WITH THE OPERATION' OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. UN -HERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FNISI-I COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT, 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS 70' FACILITATE INSTALLATION OF TIMERS. PATCH AND FNISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 18. INSTALL SMOKE DETECTORS, SEE ARCHITECTURAL SI-EET A1.0 FOR LOCATIONS OF BATTERY GRATED SMOKE DETECTORS, SEE ELECTRICAL SHEET EL0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. 19. CONTRACTOR IS TO VERIFY' THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINIS1-E8. COORDINATE WITH MECHANICAL.. 20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST' 8! PROVIDED AT RESIDENCE 8:00 All. 4 AFTER 5:00 P.M. PLAN KEYNOTES 0 0 0 0 000 0 0 0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY.: REF. WINDOW SCHEDULE. DEMOLISH EXISTNG DOOR(5), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD :AND STORM POOR REF. DOOR SCHEDULE. INSTALL yENT BAFFLE(S) AT EXISTING GABLE END VENT(S) IN ATTIC. REF. 3/422 FOR DETAIL. BLENDING. UNIT.LOCATED AND INSTALLED IN BASEMENT, REF. MECH. FOR UNIT, REP ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 4/422 FOR DETAIL. BLENDING UNIT LOCATED ADJACENT TO ( E) HATCH INSTALLED IN ATTIC, REF. MECH. FOR UNIT, REF.. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 5/422 FOR DETAIL. COORDINATE' CEILING GRILL WITH MECHANICAL DOCUMENTS. COORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL i3E CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION DETAIL. DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRES AIR INTAKE GRILLE. REF. 1/A22 FOR DETAIL. COORDINATE; WITH. MECHANICAL DOCUMENTS. INSTALL PROGRAMMABLE' TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL DOCUMENT5:. INSTALL NEW ELECTRICAL SERVICE AND ELECTRICAL PANEL.. COORDINATE WITH ELECTRICAL DOCUMENTS:. ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.. REVIEWED FOR pope COMPLIANCE APPROVED JAN 11 2013 City of Tukwila BUILDING DIVISION B. SOUTH ELEVATION C. WEST ELEVATION D. NORTH ELEVATION. LEGEND ":11=1 i ACOUSTICAL WINDOW REFER TO WINDOW SCI-EDULE N14 ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW IIIIIIIIIIIII GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL. CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. REF. MECH: 4 ELECT. REF. GENERAL NOTE 11 ATTIC INSULATION ATTIC INSULATION DAM RECEIVED CITU OF TUKWII A JAN .0 7 2013 PERMIT CEtTER Sp INSTALL BATTERY OPERATED SMOKE DETECTORS SC 'GAS INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER SOFFIT FOR MECNANICAL DUCTING 1� R)O8 S.MSTEMPER ARCHITECTS A Professional Limited liability Company 4000 DELIUDGE WAY SW SUITE 200 • SEATTLE, 1YA 98106 (206) .624-2777 • FAX (206) 624-2973 REGISTERED. A'''.!;1111:11 >c r 't,TEMP iZ 0810.03.2226 JUNE 7, 2012 I- 0 a. L.L J z 0 z W z z 0 0 z MPROVEMENTS >- 0 w W w 0 z LL U w a AIP NUMBER 3-53-0058-044 Z 0 H 0z Lct F -- DATE DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT Jo PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES A1 .0 0810.03.2226 WINDOW TYPES 2 3. CASEMENT poume HUNG IXE 4. HORIZONTAL_ )o< 801_051R WINDOW SCHE DULE VVIND. NO 1- 11 N0 0 ROOM LOCATION VVIND. TYPE LIVING ROOM LIVING ROOM 3 SIZE \Aix I -I 11-10" x 3'-10.11- 3.1-4" x; 3'-10" P-10" x 3!-10" 11 -10m -x 3'-4" K. -V-10" 111#10", 3"-10"; ▪ K 31;-.4" K 21-10" 2i -s" ▪ x 110 P-10" x 1'-10" 2'-i09*.:21-4" 3!,10." x 2'-4" 3!-10" x 7.-41! 3,-10" x 2.1-4" 31-4" x 31411 x NS" TRIM FIN SH INT./ EXT.. REMARKS !DETAIL SET LIVING 'ROOM LIVING R0011 LIvING.1‘00M 3 STAIN/STAIN. .STAN/STAN STAN/ST.AN. LIVIN4'R00.11. Ictro-rEN 2 KITCHEN 3 -KITCHEN 2 VESTIBULE; 3 vEST1SULE 3 BEDR0011 I :BEDROOM I 4 isg.pRoori. 4 BEDROOM 2 4 enrol! STAIN/STAN STAIN/STAN:, STAINisTAIN: SAFETY GLAZING REQUIRED, SHARE HEADER WITH WINDOW 5, C 1/42.0 SAFETY GLAZING REQUIRED, 614.4 RE HEADER WITI-1 WINDOW ,4, C I/42.0 ' :SAFETY GLAZING REQUIRED, SHARE HEADER WITH WINDOW .4,8 1/A2.0 SHARE HEADER WITI4 WINDOW E, F 1/A2.0 SI4AREHEADER WITH WINDOW DI, F 1/A2.0 SI4ARE 14EADER.WITI4 WINDOW D, E I/42.0 aTANtaTAIN: 1/420 STAN/STAIN. REc Room 4 STAN/STAIN. SAFETY GLAZING REQUIRED SAFETY GLAZING REQUIRED 21A20. STAN/STAN I/A2.0 VAN/STAIN I/A2.0 ST.4IN/STAIN I/A2.0 stAiwsTAK, 1/A2.0 STAN/STAIN 1./Azo- STAIN/STAN 1/A2,0 STAIN/STAIN SAFETY GLAZING REQUIRED 3/42.0 STAIN/STAIN SAFETY GLAZING REQUIRED 3/A2.0 TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS, 3. HOMEOWNER SHALL MAKE .FINAL FINISH SELECTIONS FOR WINDOWS: AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 4: FOR HEAD FLASHING INsTALLATIORREFERTO HEAD FLASHING pETAII, 'A': ON WINDOW TYPES, ser-iaouLE a DETAILS SHEET. SLOPE 1 N C MORE OA14EMNIEHEDAEPDGELAI END-HING DETAIL TYP. = - 0" I CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF-ADIERNG MEMBRANE PENETRATION PL.,451-nwrz LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. rep AT HEAP AND JAMBS. REMOVE (E) T-111 SIDNG FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. EPLACE OR RE INSTALL SIDING AS CPD. MAINTAIN (E) COURSING. PANT MODIFIED SIDING To MATCH (E) SIDING. PRE-PR1MED, GALv SHEET METAL FLASHING W/ END CLOSURE ;UNDER SELF-ADI4ERNG; MEMBRANE. COLOR TO 155'5E.LECTED IN. THE FIELD TRIM- MATCI4 (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY REMOVE (E) T -III SIDING FOR INSTALLATION OF NEW WINDOW TRIPS ,AND REATTACHMENT OF (8) SIDING TO WINDOW OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL sec= LAYER OF SEL F ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) T -III SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING TRIM- MATCH (E) TRIM. PRIME ALL 80E5 AND PAINT To MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER RQD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING $ELF API4ERING MEMBRANE TOUGH UP PAINT, AS REQ'D coNTINuars SEALANT, rrep., SOLID WOOD TRIM UJD J4II3 LINING. FINISH TO MATCH (E) SEALANT 4 BACKER Roo WINDOW HEAp... WINDOW JAMB SHIM AS NECESSARY FILL GAP W/ BATT INSULATION (E) ToUct4 UP PAINT, AS REQD CONTINUOUS SEALANT, rfP. AS NECESSARY FILL GAP UJ/ BATT INSULATION ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WNW NAIL EFLANGE TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO SE FIELD DETERMINED RrloyE (E) T-111 SIPING Fog INSTALLATION Off NEIU WINDOW ASSEI15LY AND, TR111.'NERLAca'oR RE INSTALL SIDING: AS -REOV„;pAINT MODIFIED SIDING T0 MATCH (E) SIDNG (E) EXTERIOR SHEATHING /4" BACKER ROD 4: SEALANT • 314" WOOD SILL. SQL 1. WOOD TRIM CONTINUOUS SEALANT, TYP. TOUCH UP PANT, AS REQ'D SELF -ADHERING MEMBRANE (E) GWS T-111 SIDI = 1' - 0" WINDOW SILL NG WIN DOW DETA L SET CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) T-111 SIDING FOR INSTALLATION OF NEUJUJINI:OW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQD. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. PRE -PRIMED, GAL)/ SHEET METAL FLASHING; W/ END CLOSURE UNDER SELF API4ERING MEMBRANE. COLOR TO 13E SELECTED IN TI4E FIELD TRIM- MATCI.4 (E) TRIM. PRME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR To SE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY REMOVE (E) T-M.SiDING FOR INSTALLATION OF NEW WINDOW TRIMS AND REATTACHMENT OF (E) SIDING 10 WINDOW OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL WINDOW / NAILING FLANGE OVER SELF A1DI4ERING MEMBRANE. PENETRATION FLASHING, INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE ANP LAP UNDER (E) WALL INDERLArENT, CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUS14. PAINT moosED SIDING TO MATCH (E) SIDING (E) T-111 SIDING (E) LUAU, uNDERLArMENT (E) EXTERIOR SHEATI4ING BACKER ROD 4 SEALANT WINDOW HEAD (E) LAMINATE (E) WALL UNDERLAYMENT (E)ExTERIOR 61-1EATI4ING SELF API4ERING MEMBRANE cONTNUoUS SEALANT, TYP, SOLID WOOD TRIM WD JAMB LINING BACKER ROD 4 SEALANT 5141M AS NECESSARY FILL GAP W/ BATT INSULATION (E) LAMINATE (E)GW13; CONTINUOUS SEALANT,T sem, woo TRIM LUD JAMB LINING ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER Roc, 4 SEALANT WINDOW NAILING FN TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED REMOVE (E) T-111 SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING .45 REQ'D. PAINT MODIFIED SIDING TO MATCI4 (E) SIDING (E):E:XIERIOR. SHEATHING. - VVIN DOW JAMB 11 LJ 3/4" T-111 S 3" = 1 - 0" D WINDOW SIL NG BACKER ROD 4 SEALANT SI -1111 AS NECESSARY FILL GAP al/ BATT INSULATION BACKER Roo SEALANT 3/411 WOOD SILL SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. (E) LAMINATE SELF -ADHERING MEMBRANE NDOW DETAIL SET (E) GLOB (E) EXTERIOR SHEATHING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) 1.114,1-1. UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) T -11I SIDING:FR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCI4 (E) SIDING. PRE -PRIMED, GALv SHEET METAL FLASHING WI END CLOSURE UNDER SELF-ADWERING ME11BRAIIE, COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALI_ SIDES AND P41141 10 MATc1-1 (E) "RIK cyLoR To 8E HELD DETERMINED I (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE ''°•-TOUCH UP PAINT, AS REQ'D CONTINUOUS SEALANT, TYR SOLID WOOD TRIM WO. JAM LNNG \\\VkV),\,\ BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY EXISTING CONC. WALL 11 WINDOW HEAD 4 CONTINUOUS SEALANT, TYP. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MAT04 (E) TRIM. COLOR To I8E FIELD DETER1NEP BACKER RoD 4 SEALANT AcoonpAL wNpow ASSEMBLY 64M4 NECESSARY ILL.0,4e BATT INSULATION ACOUSTICAL WINDoul ASSEMBLY BACKER ROD AND SEALANT TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PANT To MATCH (E) TRIM. COLOR TO 8E FIELD DETEst1INED WINDOW JAMB T-111 SI 3" = 1' - 0" SEALANT 4 BACKER..ROD 81-1111 AS NECESSARY FILI- GAP u)/ BATT INSULATION TOUCH UP !DANT, As WM, ..COsIT.NUOUS SEALANT, Trp; SOLID WOOD TRIM JAMB LINING SEALANT. 4 I5ACKER ROD 4. ,sEALANT /4'1 BACKER ROD 3/4" WOOD SILL SQL ID Wool) TRIM CONTINUOUS SEALANT, TYP. TOUCH UP PAINT, AS REQ'D 2fixS" PRESSURE TREATED WOOD (E) CONCRETE WALL REVIEWED FOR CODE COMPLIANCE APPROVED 'JAN 1 1 2013 • City of Tukwila BUILDING DIVISION WINDOW SILL 10 3 008 DING - WI NDOW DETAIL SET RECEIVED erry OF r rimm IJAN 07 2013 RM CkA00, S.MSTEMPER ARCHITECTS A Profesaional Limited LiahiIiy. Company 4000 DELRTD.GE WAY $W SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 0810.03.2226 JUNE 7, 2012 ce z 0 z w z 0 0 z AIP NUMBER MPROVEMENTS 3-53-0058-044 DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2226 DOOR TYPES 404 LIE FLUSI-I SCW. W/ WAGON LLilIEEL AND 4 PANELS UP SAFETY GLAZING W/ 0I3SERvATION PORT FiA14.0r,40 :2 LITES, 4 PANELS W/ SAFETY GLAZING, C EXTERIOR SINGLE LEAF STOIR11 W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR _TYPE SIZE Wx H FINISH INT,/ E.X.T. HARDWARE SET / FINISH KNOB / LEVER SET LIVING ROOM A x STAIN/ .:STAIN. Ht114. / 603 DK -4 2 KITCHEN 2c8" 643" PAINT/ iFAINT 1414 / 603 DK -3 LOCK SET LOCK -1 LOCK -i DETAI SET L I/AV 3 LIVING, R0011 3L011,x 6,40: 1142.1. 4 KITCHEg C I/A2.1 REMOVE (E) T-111SIDING FOR INSTALLATION OF NEW DOOR ASSEMBLY AND TRIM REPLACE OR RE INSTALL SIDING AS RED„ MAINTAIN (E) COUISING. PAINT MODIFIED SONG TQ MATCH (E)5IPNG. CAREFULLY LIFT CE) WALL INDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION. FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHNG. TYP AT HEAD AND JAMBS PRE -PRIMED, GALV SHEET METAL FLASi-ING END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED N TI -I5 FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME SToRII DOOR PER.ScHEDULE 2" MN. REMOVE (E) SIDING FOR. INSTALLATION OF NEW DOOR TRIMS AND OF (E) SIDING. TO DOOR OPENING, FRAMING:. LIFT(E) 0,014, Ovgnovplorr: AND INSTALL.:. SELF ADHERING MEMBRANE PENETRATION PLASHING. INSTALL. SECOND: LAYER OF :SELF ADHERING MEMBRANE AND LAP UNER (E) WALL UNDERLAIIIENT. CAULK NEW VERTICAL eviNa.jOINT$: 4SET NAIL WEARS PLUSH. PAINT MODIFIED SIDING. TO MATCH (E) SIDING (E) T -III SIDING CONTINUOUS SEALANT REWIND Z BAR FRAME STORM POOR PER SCHEDULE (E) EXTERIOR SHEATHING DOOR H KERF AS REQUIRED FOR WEATHER •STRIPPING INSTALLATION CONTINUOUS WEATHER-STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MN. POOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SLEEP EAD 2" MIN. DOOR JAM • EXISTING FLOOR STRUcTURE .100110... B SELF ADHERING MEMBRANE •TOUCH UP PAINT, AS •REap CONTINUOUS SEALANT, TYP. OLIO WOOD TRIM SWIM AS NECESSARY FILL GAP WI BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR LEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING POOR PER ScHEPULE •(E) EXTERIOR SHEATHING DOOR SILL EXISTING FRAMING TOUCH UP PAINT, AS RE0'D CCNTNUOUS SEALANT, TYP. SOLID WOOD TRIM SI-IIM AS NECESSARY FILL GAP W/ BATT INSULATION POOR PER SCHEDULE T-111 SIDING DOOR DETAIL SET 3" = 1' - 0" TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS . INDICATED, BUT NOT SCHEDULED IN SECTION 08 :.8.0 00, ALL :UN LAiVIINATEO GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING: PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED. GLAZING PER CODE. SLIDING -GLASS DOORS SHALL MATCH THE. OPERATION OF THE EXISTING SLIDING LASS DOORS THEY REPLACE OR COVER 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS. AND INTERIOR/. EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 5, FOR HEAD FLASHING, INSTALLATION REFER 10 HEACI FLASHING DETAIL ON DOOR TYPES, SCHEDULES .& DETAILS SHEET, SLOPE in. HEMMED EDGE 1 E _I L END CLOSURE HEAD FLASHING DETAIL TYP. 3" = 1' - 0" bt•0008 REVIEWED FOR CODE COMPLIANCE t APPROVED JAN 1 1 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKARA IJAN 0 7 2013 Ceo S.MSTEMPER ARCHITECTS A Profaasional Limited Liability. Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, n 98106 (206) 624-2777 • FAX (206) 624-2973 • , PI/ TJ 0810.03.2226 JUNE 7, 2.012 0 CL Ce 0 Lu 1- 0 0 MPROVEMENTS >- 0 LU 2 LU LU 0 F - LL. C.) '47Z —J F- LLJ C:1 I:e AIP NUMBER 3-53-0058-044 DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03,2226 CAREFULLY LIFT (E) WALL. UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETR4TIM FLASI4ING. TYP AT I4EAD AND .JAMOO, REMOVE (E) T-lII SIDNGFoR INSTALLATION OF VENT FIXTURE AND .PLASI-IING, REPLACE OR RE INSTALL SIDING AS REQD. MAINTAIN (E) COURSING. PANT MODIFIED SIDING To MATCH (E) GALv SWEET METAL .FLASHING WLF.F. END CAPS UNDER &APACE MOUNTED REGLET AND CAP FLASHING. PAINT COLOR TO BE SELECTED N THE FIELD. PANT VENTILATION FIXTURE, COLOR TO BE SELECTED IN THE FIELD (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATI-IING 2x 5I-OCKING 2X2 CONTINUOUS BLOCKING, 4 SIDES EXTERIOR VENTILATION FIXTURE. REF. MECI-I.- PAINT INTERIOR ID/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR !REPLACEMENT SIPNG AS REQUIP EXIST. WALL - -, (...-:----) CONST. C::-..-.-? i------) EXIST. GABLE VENT iew GALv. HARDWARE CLOTI-I AIR INTAKE 311 = 1 - 0" ETAII_ AT EXTERIOR (2) SIMPSM A-34 e EACI-I SIDE PAWL OPEN TOP cDx PLYWOOD AT (3) SIDES 11' oii1ENS CORNING 1103 INSULATION, TYPICAL. SECURE WITW PIN TYPE FASTENERS TO PLYWOOD BACK AND SIDE PANEL NOTE: I. AFTER FABRICATION, BAFFLE SHALL BE SECURELY ATTACHED IN POSITION. 2. NEW BAFFLE SHALL OE AT LEAST AS WIDE AS THE EXISTING VENT OPENNG. GABLE:. END VENT BAFFLE DETAIL 1 1127 = 1' -0" SUSPEND MECH UNITS FROM (E) STRUCTURE RE: mea-micAL MECH UNIT Arkp Ducts - REF IIECI-IANICAL DISPLACE INSULATION TO FACILITATE INSTALLATION OF MECI4ANICAL UNIT, DUCTS AND ACCESS HATCI4 BLENDING AIR UNIT 11/211 = 1' - 0" DETAIL CONTINUOUS VIBRATION DAMPENING PAID RE: Mtc1-1ANICAl_ NSULATICN STOP AT PERIMETER OF: ACCESS :HATCH 'OPENING; 4 SIDES, 2K IUD 5LOCKING EXISTING ROOF (E) ROOF FRAMNG (E);EAVE VENT BLOWN IN CELLULOSE INSULATION LUITI4 4 COMBINED VALUE OF NOT LESS THAN R--34 INSULATION DAM (E) WALL FRAMING CEILING MOUNTING BRACKET x op ANGLE IRON LEG BOLTED TO (E) STRUCTURE BLENDING AIR. UNIT DETAIL 1 1/2".= 07: • CEILING 411MN MST WERE ACCEPTABLE HERE NOTE: REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED, REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS, SMOKE DETEC 3" 1' - 0" SIDE WALL SUSPEND MECH UNIT FROM (E) STRUCTURE RE: 1:mecHANicAL. MEC1-1 UNIT AND DUCTS - REF MK:MANIC-AL OR INSTALLATION DETAIL t-beq)o8 REVIEWED FOR CODE COMPLIANCE APPROVED 'JAN 1 1 2013 City of Tukwila BUILDING DIVISION RECEIVED flow OF TuRwitA JAN 07 20131 u -o4111` CENTEP s.msTEmpER ARCHITECTS A Profeesional Limited Litibility. Company 4000 DELRIDGE WAY SW .$17E 200 • §EATTLE, WA 9840 '(06) .624-2177 • FAX (206) 624-2973 V 0810.03.2226 JUNE 7, 2012 0 0 ce 0 z z z 0 z AIP NUMBER MPROVEMENTS >- 0 ct 1.1.1 0 z U_ 0 z w 0 10-7Z' cn 3-53-0058-044 CO DATE JUNE 7, 2012 ISSUED 100% CD. PROJECT ARCHITECT J 0 PROJECT MANAGER ML&TF DRAWN LB&CP MISC. DE -TAILS A2.2 0810.03.2226 LIFT (E)SLIDG. PAPER AWAY LOOSELY FROM (E)' SHEATHING AT ./AM150. AND HEAD BUTTERFLY CORNERS, TYF'. NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS RE= (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND ;•-• OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED (E) SHEATHING 12° CUT SILL FLASHING 4 FOLD THROUGH R.O. AS SHOWN. LAP SILL MEMBRANE. FLASHING 2-1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND I i" BEYOND R.D. AT EA. END OF SILL (E) BLDG. PAPER AT SILL ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF 0.444.1. SHEATHING 1/2" TYP. MEMBRANE FLASHING AT SIL L Z9 BUTTERFLY CORNER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMS AND HEAD. (E) SIDING NOT NOM FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REOV (E) SIDING NOT $140WN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL. ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'IRS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW ME 4 I SCALE: NTS. REMOVED (E) SIDING NOT SHOWN DIAGRAMATICALLY. EDGE OF (E) SIDING, SI -1011N FOR CLARITY. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS MBRANE INSTALLATION MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENI105. SEND ANCHORAGE NAILS DO(LN OVER NAIL FLANGE, HEAD ONLY. CE) SHEATHING NOTE: REMOVE (E) SIDING BACK FROM ()pC. AS Warp (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AMER MEMSIRANE FLASHING HAS BEEN INSTALLED. WHERE REQUIRED, TRIM (.E)::BLDG PAPER AT HEAD 0 PREPARE FOR INSTALLATION OF HEAD F ASI-ING AND •.1140011) TRIM (FOLLCWNG STEPS). HEAD FLASHING PREPARATION SCALE: NTS (E) BLDG. PAPER NOTE; REMOVE (E) SIDING. SACK FROM (E) Ra AS REQ'D (E) SIDING NOT swam FOIR CLARITY. REPLACE MD OR INSTALL NEW SIDING AFTER MEMERANE FLASHING I445 BEEN INSTALLED. GUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SI -1001. ExTm, 1-1/2" BEYOND EDGE OF OPENING AT HEAP, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E.) SIDING SACK FROM CE) R.O. AS REGI'D (E) SIDING NOT 51400,1 FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 3 - INSTALL JAMS FLANGE FLASHING OVER WINDOW NAILING. FLANGE AND PLASHING. INSTALL SHT.mETAL HEAD, PLASHING UNDER CE) BLDG PAPER MEMBRANE. FLASH SCALE: NTS NOTE:. ING AT JAMB NOTE; REMOVE (E) SIDING. SACK FROM .(E) RD. AS lea!". (E)SoING NOT SI4OlLN FOR CI-ARITY. REPLACE AND OR INSTALL. NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. ALLOW 1/8" CLEARANCE OP (E) TRIMMED EDGE SHOILN DIAGRAMATICALLY. (E) SIDING NOT SHOUN FOR CLARITY. BETWEEN FLASHING. AND 130T. EDGE OF (E) SIDING. HEAD FLASHING INSTALLATION SCALE: NTS CE)BLDG. PAPER INSTALL HEAD FLANGE FLASHING OVER4-Aspow NAILING FLANGE AND FLASHING. CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SWOLN. EXTEND 1-1/2" BEYOND R.o. AT I4EAP AND JAMBS. ADHERE. PENETRATION FLASHING TO OUTSIDE FACE OF WALL. SHEATHING (TYP. EACH SIDE OF WALL) MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RD, AS REQ'D CE) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW. SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. :4. 41'14: a Th WINDOW FLASHING SCALE: NTS NSTALLATION SHEET METAL HEAD FLASHING C9 WOOD TRIM INSTALLATION SCALE: NTS (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW. TRIM AND SIDING. LEAVE 1144"3/Olt GAP BETWEEN WINDOW TRIM AND WINDOW MAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS "SELF ADHEARING MEMBRANE FLASHING!' TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "1.2. AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO 11J110011) INSTALLATION 3: DETAILS "5 AND 6" REFER TO MEMBRANE. INSTALLATION AFTER WINDOW WAS BEEN SET IN PLACE, SHIMMED, AND ANci-ioRED. 4: DETAILS "1 AND 5» REFER TO SHEET METAL I-IEAD FLASHING. 5: DETAIL 5 REFERS TO WOOD TRIM AND CAULK. JOINTS. b3 009 REVIEWED FOR CODE COMPLIANCE APPROVED 1JAN 11 71111 City of Tukwila BUILDING DIVISION RECEIVED °ITV OF llikiAni.A I JAN 07 2013 RMIT CENTh S.MSTEMPER ARCHITECTS A Pr ofeasional Limited Liability Company 4000 DELRID.G2 WAY SW SUITE 20.0 • SEATTLE, WA 90106 (206) 624-2717 • FAX (206) 624-2973 iuir 0810.03.2226 JUNE 7, 2012 ce z 0 z rt LU z 0 00 z AIP NUMBER MPROVEMENTS ›- LU LU LU ce 3-53-0058-044 z 0 F- 0 DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW FLASHING DETAILS A2.3 0810.03.2226 ABBREVIATIONS LEGEND 1:1RAWINIG INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW H WC HWG HWR HWS IN KW LAT LING LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT 00 OBD PH POC PSI RA REF REQD RG RPM •SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING - ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN. SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW !FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL. UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER' MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE, DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR .ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL 'STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER miNuTE: FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING,. VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY' INCH KILOWATT, (1000 wATTs). LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING' WATER TEMPERATURE, MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO ,SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE. ON CENTER, OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED. RETURN, GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY ',DIFFUSER SHEET SHEET METAL sEATTL:•mEcHANI0AL: CODE SCREENED OPENING. STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS: SEATTLE RESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE' NOTE DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS USTED SYMBOL. A13.15.13. OR XX IMII=11111•11I1S 81111.11IIIIMM.! DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND. DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS m21,1 DETAILS GENERAL NOTES 1. THE MECHANICAL ,:SYSTEM S.H.ALL. CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE. spEGFEQATIoNs,, WORK: INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. 'PROVIDE A., COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH. ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS USTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION, CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM. PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED. AIRTIGHT. 8. PROVIDE ALL REQUIRED. ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS. REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7, PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8„ COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, .WITH THE TECHNICAL REPRESENTATIVE, LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY, LOCATE THERMOSTATS 41—O" AFF. UNLESS NOTED OTHERWISE. 9 PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN '1O—OM CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS. REQUIRED. 12. MAINTAIN 3'—O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR: SYMBOL. XXX ABBR I- DN I + + 1- uP S. eTh'641.41e'' -01- 41. .L. DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD VOLU RA/EA RG SA SA RA/EA SD ME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE. SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION — RECTANGULAR: TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH TOR (. THERMOSTAT EQUIP IDEQUIPMENT LOCATION NG r. 0 MOD NG MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL/EL EC:TR -CAL.'COORDINATIDN ITEM NO. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURN SHED UNDER DIVISION INSTALLED UNDER DIVISION 23 26 23 26 N/A WIRED UNDER DIVISION 26 23 N/A REMARKS :V -I,, BLENDING UNIT VENTILATOR X 1,2 SWITCHES (ON, TIMER) 20 x REMARKS: I - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DI MENSI ONS ELECTRICAL. WATTS VOLTS PHASE COMMENTS BV -I 115 .5" WG 32"Lx12,25"Wx8.5"1-1 76 120 1, 2, 3 BV -2 140 32"Lx12. 25"Wx 8. 5"H 76 120 2, 3 NOTE: I. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CATS) WITH THE MANUFACTURER, 2, PROVIDE WITH SPEED CONTROL BASIS OF DESIGN: ALOES AMERICAN A. OR APPROVED. EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK STATIC INLET OR NECK DucT CFM 1 PRESSURE SIZE CONNECTION: LOCATION. MODEL # REMARKS SG -I SG -2 115 <,Or -WO 7" WALL ALLGR1LLE I, 2,4 140 8" CEILING ALLGR1LLE 1, 2, 4 0O-1 00-2 RG -1 RG --2 90 90 ‹.08" WO <.08" WO 7" 7,,. WALL 7" WALL WALL. CAP ALLGR1LLE 1, 2, ,4 25 <.08 WG 4" WALL DECO 25 <.08" WO DECO I, 2, 3, 4 I. 2, 4 I, 2, 4 REMARKS: I. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 3.,PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 4. BASIS OF DESIGN: ALOES A. OR APPROVED EQUAL. 5. 'BASIS OF DESIGN: SHOEMAKER A. OR APPROVED EgyAL, 6. PROVIDE WITH AN OPPOSED BLADE DAMPER WAC RESIDENCE CODE FLOOR AREA ($.Q. FT,) NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2226 BV -I. 471 90 CFM CFM 0810.03.2226 BV -2 1049 2: '90.c:F.m, 90 CFM 1, VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51-51-1508, TABLES MI2 AND MI506.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION MIN VALUE NOTES ON ROOF OR ON EXTERIOR OF BUILDING R-8 WITH WEATHERPROOF BARRIER 1.3 ATTIC, GARAGE. CRAWL SPACE IN WALLS. IN FLOOR/CEILING R -B 1.2.3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -B 1.3 IN CEMENT SLAB OR IN GROUND R-5 1,3 NOTES: THICKNESSI. OF INSULATION IS DEFINED AS THE THICKNESS ,OF THE I3ASIC INSULATING' MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH SIRES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR, 3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. TH DRAWING ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 011101 AND 028200 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. ERMOSTAT -SW1TCH HOURS OF OPERATION_ SET BV -1 SWITCH TO OPERATE 1 OF EVERY 3 HOURS. SET BV -2 SWITCH TO OPERATE 1 OF EVERY 2 HOURS. BV -1 MECHANICAL, VENT ATION. :CALCULATION PER WAC 51-51 M1508,3: QF = OR (&EGR X F) QR = (FROM TABLE M1508,2) la &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/3 QF = 30 / (1 X 1/3) = 90 CFM BV -2 MECHANICAL .... :CALCU.LATION.., PER WAC 51-51 M1508,3: QF = QR / (&EGR X F) QR = (FROM TABLE M1508.2) L5_ &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 OF = 45 / (1 X 1/2) = 90 CFM oo SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED MIN OF TUKWILA JAN 07 203 JW40411T CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS. A Pram:Ilona Molted !bitty Company 4000 DELRMGE WAY SW STATE 200 ^ SEATTLZ, WA 08108 (206) 624-2777 ^ PAX (206) 024-2978 THE GREENBUSCH GROUP. INC *SO 099*** ))) 611411.1911CAL, AU120 / ID & IMICHNIICAL DicanniNG 1900 111111 ,N ST56ErSUITE 201 917311.E. OM 66119 (206) 37/3-0589 (206) 378-0641 FM 0810.032226 IMPROVEMENTS AIP NUMBER 3-53-0058-044 DATE 06/06/2012 ISSUED 100% CD. PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1 0810.03.2226 HOLD TIGHT TO JOISTS RELOCATE WIRE AS NEEDED LOWER FLOOR SCALE: 1/4" M EC-HANICAL PLAN.. • .. LOWER KEY TO VENTILATION 10 NONE NORT• 00-1 90 SEE CORE THROUGH RIM. JOIST NES KITCHEN 011.0001•1111111•111 x 22ExIST. ATM ACCES8 PANEL DINING ROOM LIVING ROOM SG --2 140 CEILING GRILLES MOD MAIN FLOOR_ •SCALE: 1/4" =11-0" BV -1 ATH CLOSET !BEDROOM 2 MECHANICAL PLAN DRAWING NOTES: 11 11 11 11 11 11 11 11 11 11 11 11 11 L 1 1 i } L SEE TYP GABLE AT SECOND ROOF 80 DN TO ..0 1 4"0 DN 1 TO IR s _ SEE - ATT11C-M ECHANICAL • p. scAL, :-0" 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51, SECTION M1508.6.6. 2, FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN ThEl FURNACE AND/OR BLENDING AIR UNIT SYSTEMS WITH NEW FILTERS. 4"0 DN. TO RG -1 1 1 1 1 L LAN TYP NIC#DRTH FLAG NOTES: BV -1 AND DUCTWORK ROUTED IN LOWER FLOOR. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS WITH TECHNICAL REPRESENTATIVE. Bv-2 AND DUCTWORK ROUTED IN ATM. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51, SECTION M1508.6.4. COORDINATE FINAL SWITCH LOCATIONS WITH HOMEOWNER. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION, PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED crry OF TUKWILA 1JAN 0 7 2013 WAIT CENU STEMPER ARCHITECTS1 Prefessilos.al Uraited bft Cersopew 4000 DELRIDGE WAY SW SIMI 300 SELYME, WA 0.0A08 (RO) M4-27.77 ^ TAX (20) 824.,297S THE. GREENBIJSCH GROUP, INC 00.000 ACOUSI1CAL, AUDIO / VISO IMICHASICAL DUNEDIN 1000 1IfST i1I SSW SUITE XII SENILE. WA 16110 (200) 57a-01569 (200) 278-0041 FAX 0810.032226 IMPROVEMENTS RESIDENTIAL AIRCRAFT NOISE REMEDY AIP NUMBER 3-53-0058-044 DATE 06/05/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL FLOOR PLANS M2.0 0810.03.2226 OUTSIDE AIR DUCT RETURN AIR DUCT HOLD TIGHT TO STRUCTURE SUPPLY AIR DUCT MOTOR ACCESS FILTERS ACCESS NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 3. INSULATE ALL DUCT AS SCHEDULED. 41 SCALE: NONE BV -1 INSTALLAT ION DETAIL CAULK SHEETMETAL TRANSITION TO GRILLE NECK SIZE 2X BLOCKING FOAM BACKER ROD DUCT PER PLAN 2X BLOCKING WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3 WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. i,V11O • RETURN AIR DUCT OUTSIDE AIR DUCT HOLD TIGHT TO STRUCTURE MOTOR ACCESS FILTERS ACCESS SUPPLY DUCT NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE. BV -2 I NSTALLAT ON DETAIL SCALE: NONE SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE 2X BLOCKING SLEEVE AND ESCUTCHEON GRILLE DUCT PER PLAN COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE FOAM BACKER ROD CAULK 2X BLOCKING FLOOR OR CEILING JOIST CEILING NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CE [LtN1G GRILLE DETAIL. SCALE: NONE SHEETMETAL TRANSITION TO WALL CAP NECK SIZE DUCT PER PLAN CAULK 2X BLOCKING 2X BLOCKING FOAM BACKER ROD WALL CAP SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS, 3. COORD. W/ARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1/A2.2 FOR DETAIL. WALL CAP DETAIL SCALE: NONE b 13•0013 RECEIVED CITY OF TUKWILA I JAN 07 2013 PERMIT CEMP SEP 440 Aip A 61&• %I/A NO 4=QUIR EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS Proteasional lip33142 Liabilliq Company 4000 »ELRIDGE WAY SW SUITE 200 SEATTLE, WA 90106 IMO 21124-2n7 (Oe) 024-21215 TEE GREENBUSCH GROUP, INC 0 • 0000 0** A0012111211.. AU010 / VIDEO & 112241/211:AL 00211113110N0 1000 111211` SMILT SUITE 201 SENTLE. 10t 00110 (205) 078-0509 (200) 375-0041 FAX 081 OE.032226 ROVEMENTS 0 w 0 LL 0 ce a AIP NUMBER 3-53-0058,044 DATE 0610512012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN „IA, DT DETAILS M2.1 0810.032226 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. E LECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. PROVIDE TINIER SWITCH AND COMPLETE CONNECIIONS TO BLENDING UNIT. SEE SPECIFICAllONS FOR TYPE. HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. L_ UNFIN 5ASEMEN.T NO PROVIDE PROVIDE MINIMUM 38' CLEARANCE AROUND SERVICE WIRES PER SCL REQUIREMENTS. METER AND FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY CHARGES IN BID. ELECTRICAL LEGEND Orr301- DESCRIPTION VISO- ESCRIPTION IJGHTING OR POWER PANEL BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS), PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2°C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. INDICATES ISOLATED GROUND. MAST, WEATHERHEAD BRANCH :CIRCUIT HOME RUN EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. DAMPER CONNECTION NON-FUSED DISCONNECT SWITCH TOGGLE TYPE MOTOR DISCONNECT SWITCH WITh THERMAL OVERLOADS SMOKE DETECTOR ELECTRICAL ME TIMER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE W1111 UTIUTY. CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT C) THERMOSTAT UNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR PROVIDE NEW METER BASE RIGID STEEL MAST, WEATHER HEAD, ANCHORS, ROOF FLASHNG, PATCHING,: AND CONDUCTOR PIGTAILS, CONFORM TO SCL REQUIREMENTS. FINAL CONNECTIONS' BY SCL. INCLUDE ALL UTILITY SERVICE FEES IN BID. DEMO EXISTING PANEL USE AS J. NOTION BOX. EXTE/ D E ISTING CIRCUITS TO NEW IP NEL I / • I <ICH, NI: _1 - 22" ATTIC. AC0E05 PANEL NI NIC1 (..)OM NEW PANE AND PANE . SEE DETAIL SCHEDULE MECHANIGAL / ELECTRICAL C00— NATION ITEM Na. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS FURNISHED. UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DMS ON 15 16 15 16 N/A. 15 16 N/A REMARKS 8V-1 BLENDING UNIT VENTILATOR 120. X • XI 'X 1,2 SWITCHES (ON, TIMER) 120 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH =77 CLOSET 15E1D fR.001'1 L P T- L T- — -1 I I / I. / / L. T---7-TH , L ATTIC PLAN 118" = 1' rl 7 SEPARATE PERARTAND REQUAPPRovAL IRED ECEIVED CITY OF Tvwvinuk IJAN 07 2013 ,i1A41; (;tik 4 L S.msTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200, • SEATTLE, WA 98100 (206) 624.2777 • FAX (206) 624-2913 0810.03.2226 NTERNATIONAL AIRPORT MPROVEMENTS >-- 0 w LU U o. 0 0 z w 0 Z < ci) w AIP NUMBER 5-53-0058-044 SEATTLE WASHINGTON DATE JUNE 7, 2012 ISSUED 10.0% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES El .0 0810.03.2226 RAN EL MP LOCATION" SERVING:RESIDENCE • • iVOLT I PHASE. 1 3'10.414E. too-oct AIC .200. AJvP with MAIN BKR CKT LOAD D ESCRIPT1ON :7.TYPE KVA NP PHASE OW' KVA TYPE • LOAD DESCRIPTION CKT EXISTING LOAD 3 :EASTING LOAD • 7 9 1:1i8XISTINGLOACt 11igkiStINOIOAD! 15;EXISTING LOAD • 17 EXISTING LOAD 11VEXISTING LOAD 21 EXISTING LOAD 23EXISTING LOAD 25 BLEISIDINGUNIT1 27 BLENDING .• 29 ''ath 33 5012 012 3 012 A A A B 20/2 3oa 2012 EXISTING LOAD DOSING LOAD EXISTING LOAD 2 4 12 1511 204 20/1 A A B A B A 3 39 41 B A B A A 2012 30/2 1#11,,,,„ 1511 . . . I it 14 16 EXISTING LOAD 18 ENST1NGLOAD. .. . . EXISTft4GLOAti• 20 '22' 24 EXISTING LOAD 26 EXISTING LOAD -24; 30 32 34 36 38 40 42 PH ASE LOAD P'IASEA= „ . KVA, PHASE B= • KVA: - LOAD TYPE H A LINA '-'TOTAL VCIAQ$1 CONN. LOAD p COMPUTED LOAD KVA AMP ISOLATED GROUND BUS :;!:laKftSHIJNI7D3R PANEL SKIRTS SURFACE ... .. ....... . . ,,,,,,,,,, RNTIGHTNEMA3R ENCLOSURE ,, D BLE LUGS LABEL iimagRAL,wss: ElliFLUSH REMARKS:: PROVIDE• NEW RIGID STEEL MAST, WEATHER HEAD AND CONDUCTOR PIGTAILS PER SCL REQUIREMENTS. FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY SERVICE FEES IN BID. PROVIDE NEW MAST GUYS AND ANCHORS VOOF „---- 2"C, 3#3/O CU METER AND FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY CHARGES IN BID. PANEL MP 200A 120/240 1 -PH, 3W PROVIDE NEW SERVICE DROP FROM POLE TO HOUSE BY SCL. ALL FEES PAID BY CONTRACTOR. 20c, 3#3/0 CU.& GND PROVIDE METER BASE PER SCL STANDARD #DU13-4/NWIT-30 #4CU GROUNDING ELECTRODE CONDUCTOR AND GROUND RODS PER CODE. MAX 10 OHMS TO GROUND k: A PROVIDE NEW NEMA -1 S.E. RATED :PANEL: BOARD. INTERCEPT AND EXTEND EKIsliNo CIRCUITS AND CONNECT TO NEW BREAKERS. PROVIDE ALL REQUIRED CUTTING AND PATCHING AS REQUIRED TO COMPLETE THE WORK AS DESCRIBED ABOVE AND ON DRAWINGS. ROUTE CONDUIT EXPOSED ON OUTSIDE OF HOUSE. PROVIDE STRUCTURAL SOLID 2X6 BLOCKING IN ATTIC FOR MAST. PROVIDE BLOCKING AND UNISTRUT ASSEMBLIES TO HOLD CONDUIT AWAY FROM HOUSE SURFACE TO ALLOW FOR EXISTING CONDITIONS. VISIT THE SITE TO ESTABLISH EXACT CONDITIONS PRIOR TO BID. NEW SERVIC E DETAIL SCALE:NONE b11008 SEPARATE PERMITAND APPROVAL REQUIRED RECEIVED Crry OF TUKWILA JAN 0 7 2013 CENTEI. S iM:STEPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 98100 (20) FAX (266) 04-2973 0810.03.2226 0 a AIP NUMBER MPROVEMENTS 5-53-0058-044 SEATTLE WASHINGTON DATE. JUNE 7, 2012 ISSUED 100% PROJECT ENGINEER CHL PROJ ECT MANAGER BCR DRAWN JAB FLOOR PLANS 8( NOTES Eli 0810.03.2226