HomeMy WebLinkAboutPermit D13-009 - CHRISTENSEN RESIDENCE - REMODELCHRISTENSEN
RESIDENCE
12212 48 AV S
D13-009
City o?Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
Parcel No.: 0179001355
Address: 12212 48 AV S TIIKW
Suite No:
Project Name: CHRISTENSEN RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D13-009
Issue Date: 01/15/2013
Permit Expires On: 07/14/2013
Owner:
Name: CHRISTENSEN TAYLOR R+DAVID
Address: 12212 48TH AVE S , TUKWILA WA 98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: G & G SPECIALTY CONTRCTORS INC
Address: 4633 S 36 ST , PHOENIX AZ 85040
Contractor License No: GGSPEGS919RT
Lender:
Name:
Address:
Phone:, 206 296-7437
Phone: 480-921-4079
Expiration Date: 12/31/2013
DESCRIPTION OF WORK:
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE - WORK TO POTENTIALLY
INCLUDE SELECTIVE REPLACEMENT OF WINDOWS, SELECTIVE REPLACEMENT OF INTERIOR/EXTERIOR DOORS WITH NEW
ACOUSTICAL DOORS, INSTALLATION OF SECONDARY SLIDING GLASS DOORS AND SKYLIGHTS, ETC.
Value of Construction: $31,174.00 Fees Collected: $1,141.27
Type of Fire Protection: International Building Code Edition: 2009
Type of Construction: VB Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
**continued on next page**
doc: IBC -7/10
D13-009 Printed: 01-15-2013
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Permit Center Authorized Signature:
N
N
N
Number: 0 Size (Inches): 0
Start Time: End Time:
Volumes: Cut 0 c.y. Fill 0 c.y.
Start Time: End Time:
Private: Public:
Profit: N Non -Profit: N
Private: Public:
I hereby certify that I have read and e
governing this work will be complied
Date:
rotlsI'5
ed this permit and know the same to be true and correct. All provisions of law and ordinances
hether specified herein or not.
The granting of this permit does not pres e to give authority to violate or cancel the provisions of any other state or local laws regulating
construction ojth0 performance work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this pe
Signature:
Print Name:
D Dteee
Date: ( -IS.— / 3
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431-3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: All wood to remain in placed concrete shall be treated wood.
7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
doc: IBC -7/10
D13-009 Printed: 01-15-2013
sewer connections, and properly fill or other. protect all basements, cellars, septic tanksighlls, and other
excavations. Final inspection approval will be determined by the building inspector based dirisfactory completion of
this requirement.
8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D13-009 Printed: 01-15-2013
•
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.cLtukwila.wa.us
Building Permit No.
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.: 0179001355
Site Address: 12212 48th Ave. S.
Tenant Name: Taylor Christensen
Suite Number:
Property Owners Name: Taylor Christensen
Mailing Address: 12212 48th Ave. S.
Floor:
New Tenant: 0 Yes ® ..No
Tukwila
WA
98178
City
State
Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296-7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker@kingcounty.gov
City State
Fax Number: (206) 269-7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
City
Day Telephone:
Fax Number:
Contact Person:
E -Mail Address:
Contractor Registration Number: Expiration Date:
State Zip
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody@smstemper.com or tim@smstemper.com
City State
Day Telephone: (206) 624-2777
Fax Number: (206) 624-2973
Zip
ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
H:\Applications\Forns-Applications On Line\2009 Applications \I-2009 - Permit Application.doc
Revised: 1-2009
bh
City
Day Telephone:
Fax Number:
State
Zip
Page 1 of6
•
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price): $ 48,1'C9 9)11 11 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? 0 Yes
m.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? 0 Yes m No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
O Sprinklers 0 Automatic Fire Alarm • None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forms-Applications On Line\2009 Applications \I-2009 - Permit Application.doc
Revised: 1-2009
bit
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
lst Floor
772
2"d Floor
3`d Floor
Floors thru
Basement
772
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? 0 Yes m No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
O Sprinklers 0 Automatic Fire Alarm • None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forms-Applications On Line\2009 Applications \I-2009 - Permit Application.doc
Revised: 1-2009
bit
Page 2 of 6
PLUMBING AND GAS PIPING PERMIT INFORMATION — 206-431-3670
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1-5
inlets/outlets for a
specific gas
Each additional medical
gas inlets/outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:\Applications\Fonns-Applications On-Line\2009 Applications\I-2009 Permit Application.doc
Revised: 1-2009
bh
Page 5 of6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNE
Signature:
IZED AGENT:
if*"
Print Name. of J. enlason, SM Stemper Architects, PLLC (206) Day Telephone:
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
Date: I/ 7 1
62 7
(4-2
City
State
Zip
Date Application Accepted:
iCJ
((ff yet b1 1 lc
Date Application Expires:
ol (0,,)
f
I
Staff Initials:
�-
H:\Applications\Fonns-Applications On Line\2009 Applications \1.2009 - Permit Applicamon.doc
Revised: 1-2009
bh
Page 6 of 6
City o'ukwilar
Department of Community Development
6300 Southcerter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: htip:/Svww.ci.tukwila.wa.us
SET RECEIPT
•
RECEIPT NO: R13-00124
Initials: JEM
Payment Date: 01/09/2013
User ID: 1165 Total Payment: 13,045.45
Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE)
SET ID: S000001897 SET NAME: KING COUNTY NOISE ABATEMENT
SET TRANSACTIONS:
Set Member Amount
D13-004 1,018.34
D13-005 1,239.61
D13-006 1,313.36
D13-007 779.67
D13-008 1,116.68
D13-009 1,141.27
D13-010 1,313.36
D13-011 1,092.10
D13-012 1,239.61
D13-013 1,092.10
M13-003 167.70
M13-004 186.50
M13-005 177.10
M13-006 167.70
M13-007 177.10
M13-008 177.10
M13-009 124.25
M13-010 177.10
M13-011 167.70
M13-012 177.10
TOTAL: 3 x-61-8' 1- 34" _
TRANSACTION LIST:
Type Method Description
Amount
Payment Credit C VISA 13,045.45
TOTAL: 13, 045.45
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
000.322.100 6,849.15
City c Tukwilar
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: htto'/Avww ci tukwila wa us
STATE BUILDING SURCHARGE
•
640.237.114 45.00
TOTAL: 13, 045.45
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
fl (3 -coq
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 , le (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
Type o . Inspectio{ : A.,
t
U 4 A6
Address:Date
( 1J Z .4- AUL:
Called:
dot. A..)...—VvG
_
Special Instructions:
/
Date Wanted:
—11
m.
—13 4
Requester:
Phone No: - Frt"
09 to
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
Inspector: j VI
Date.:)? t"--/ —'
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
a
Jennifer Marshall
From:
Sent:
To:
Cc:
Subject:
Tim Fenlason <tfenlason@jonespayne.com>
Tuesday, January 08, 2013 11:29 AM
Jennifer Marshall
sharyn.parker@kingcounty.gov; Jesse Holgate
Re: KCIA RANRIP Submittal
You are correct. I'd like you to change the applications to reflect the amounts in the pink column. I thank you
for this extra work and if you'd like, I can gladly drive to your office to make the changes.
On Tue, Jan 8, 2013 at 9:56 AM, Jennifer Marshall <Jennifer.Marshall@,tukwilawa.gov> wrote:
Good morning Tim,
Due to the fact that I cannot just arbitrarily change information on permit applications, I am clarifying the direction you
are giving me. Are you directing me to update the valuations provided on the applications submitted yesterday to the
numbers below under the column highlighted pink and labeled "Value Originally Provided?"
Applicant Name
Ochoa Residence
Nguyen Residence
Aragon Residence
Aragon Residence
Carter Residence
Christensen
Residence
Fasano Residence
Kerr Residence
Nguyen/Diem
Residence
Rivera Residence
Address
11863 44 Av
S
5016 Wallace
St
4610 S 124 St
12245 46 Av
S
1180240P1S
12212 48 Av
S
12029 44 Av
S
3834 S 116 St
11620 40 Av
S
11826 44 P1 S
Dev Permit Value Provided on
No Application
D13-004 $24,018.00
D13-005 $31,135.00
D13-006 $32,099.00
D13-007 $17,201.00
D13-008 $25,472.00
D13-009 $28,169.00
D13-010 $37,403.00
D13-011 $23,133.00
D13-012 $33,129.00
D13-013 $23,619.00
Value Originally
Provided
$26,622.00
$35,359.00
$38,407.00
$19,973.00
$30,978.00
$31,174.00
$38,918.00
$29,764.00
$35,722.00
$29,761.00
If these numbers are correct please respond accordingly and I place a copy of these emails in the file proving that I have
been authorized to make the changes. If they are not correct, please provide me with the correction valuations.
Thank you,
Jennifer Marshall
Permit Technician
Original Message
From: Tim Fenlason [mailto:tfenlason@ionespayne.com]
Sent: Monday, January 07, 2013 4:18 PM
1
To: Jennifer Marshall
0
Cc: sharyn.parker@kingcounty.gov; Bill Rambo; Jesse Holgate
Subject: Re: KCIA RANRIP Submittal
Jennifer,
My preference would be to use the amount provided to Bill and to update the applications. I know that the amounts
provided to Bill are correct, as I did those calculations myself.
On Mon, Jan 7, 2013 at 4:08 PM, Jennifer Marshall <Jennifer.Marshall@tukwilawa.gov> wrote:
> Good afternoon Tim,
> I received the applications and plans for ten lots for the above
> referenced project. I have completed the data entry in our permit
> system and discovered there are discrepancies with valuations provided
> to Bill Rambo and the valuations provided on the applications. I have
> attached a spreadsheet showing those discrepancies. The issue with
> there being a difference is that the permit estimate provided from
> Bill is no longer applicable.
> It is the end of my work day, so I will wrap this up tomorrow morning
> (I probably will not be able to fit it in until about 10 am) and
> provide the updated permit fees which will correspond with the new
> valuations given. At that point we will need payment to be made
> before the permits can begin the review process. I have also attached
> the original worksheet you and Bill were working with for your reference.
> Have a good evening.
> Jennifer Marshall
> Permit Technician, City of Tukwila
> T: 206 431-3670, F: 206 431-3665
> iennifer.marshall@tukwilawa.gov
Tim Fenlason Associate AIA
Senior Job Captain
2
ERMIT CO6RD COP'
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: D13-009 DATE: 01/07/12
PROJECT NAME: CHRISTENSEN RESIDENCE
SITE ADDRESS: 12214 48 AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
AVC
uilding Division
Public Works
tiv‘g ANe M.L.117
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete ❑
DUE DATE: 01/10/13
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
TUES/THURS ROUTING:
Please Route t
REVIEWER'S INITIALS:
Structural Review Required ❑ No further Review Required ❑
DATE:
APPROVALS OR CORRECTIONS:
Approved ❑
Notation:
REVIEWER'S INITIALS:
DUE DATE: 02/07/13
Approved with Conditions Not Approved (attach comments) ❑
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Contractors or Tradespeople Piker Friendly Page
•
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite/Apt.
City
State
Zip
County
Business Type
Parent Company
G & G SPECIALTY CONTRCTORS INC
4809214079
4633 S 36Th Street
Phoenix
AZ
85040
Out Of State
Corporation
G & G SPECIALTY CONTRCTORS INC
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
602975812
Active
GGSPEGS919RT
Construction Contractor
12/31/2009
12/31/2013
General
Unused
Business Owner Information
Name
Role
Effective Date
Expiration Date
GOODBALLET, CHARLES ELMER
Chief Executive Officer
12/28/2009
Bond Amount
WAVY, CHRISTINE
Chief Operating Officer
12/28/2009
59BSBEA9058
GOODBALLET, JAMES SCOTT
President
12/28/2009
GOODBALLET, TERESA LYNN
Secretary
12/28/2009
INS CO OF THE WEST
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
2
HARTFORD FIRE INS
CO
59BSBEA9058
12/18/2010
Until Cancelled
$12,000.00
01/03/2011
1
INS CO OF THE WEST
2278440
12/18/2009
Until Cancelled
$12,000.00
12/28/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
4
Companion
Property & Cas
Ins C
PCP10000270101
11/03/2012
11/03/2013
$1,000,000.00
11/16/2012
3
National Union
Fire Ins of PA
PCP1000027
11/03/2011
11/03/2012
$1,000,000.00
12/27/2011
2
LEXINGTON INS
CO
4392611702
12/31/2010
12/31/2011
$1,000,000.0001/11/2011
1
LEXINGTON INS
CO
4392611701
12/31/2008
12/31/2010
$1,000,000.0001/14/2010
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
01/15/2013
KI
NG
COUNTY
... ... INTERNATIONAL AIRPORT
DENTAL AIRCRAFT NOISE
REMEDY IM
PROV
EMENTS PROGRAM
SCOF,E.
F WORK
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE
MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORMATION N THE DRAWINGS AND
SPECIFICATIONS INCLUDING BUT NOT LIMITED TO:
APPLICABLE
YES NO
1 SELECTIVE REPLACEMENT C EXISTING WINDOWS WITH NEW VINYL -FRAMED ACOUSTICAL WINDOWS.
x
2. CUT DOM OF WINDOWS TO COMPLY WITH EGRESS REQUIREMONTS.
x
3. INFILL. OF EXISTING OPENINGS.
x
4. SELECTIVE REPLACEMENT OF INTERIOR EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS.
5. INSTALLATION OF STORM DOORS.
6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS.
x
1. INSTALLATION OF SECONDARY SKYLIGHTS.
x
8. INSTALLATION OF PET DOORS.
x
S. NSTALLATION OF FIREPLACE FRESH AIR VENT..
x
10.
INSTALLATION OF CHIMNEY CAP.
x
11. REGULATED MATERIALS ABATEMENT.
x
12. ATTIC VENT BAFFLES.
x.
L3. INSTALLATION OF ATTIC INSULATION.
x
4. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLINDING AIR UNIT AND
ASSOCIAThP DUCTING.
x
15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMEV, FURNACE MODIFICATION ANP
ASSOCIATED PUCTNG.
x
10, ARCHITECTURAL 'MODIFICATIONS TO SUPPORT- NSTALLATION OF' ME0141ANICAL, vENTILATIOK.
11. ELECTRICAL MODIFICATIONS TO SUPPORT
ARCHITECTURAL MODIFICATIONS.
NSTALLATION OF MECHANICAL VENTILATION AND
x
1S. INSTALLATION OF SMOKE DETECTORS.
x
IS. NEW ELECTRICAL PANEL / SEIRVICE.
x
24iX KNOB Als1D •TUBE WIRING,
SEPARATE PERMIT
REQUIRED FOR:
*lichanical
ar: Electrical
finiumbing
[Was Piping
aty of Tukwila
BUILDING DIVISION
F!
Peri No.
Pt", r-Itisw approval is subject to errors and omissions.
'L)o construction documents does not authorize
t 31 any adopted code or ordinance. Receipt
Li.4.drovidiv
y isacknowledged:
By /-
City Of lbkwila
BUILDING DIVISION
411.1111141,.
REVISIONS
No changes shall be made to the scope
of work without prior approval of
71:'..milla Building Division.
r:: ; s,VOn3 will require a new plan Submittal
cnd may include additional plan review fats.
C00747C12
BI
D -PACKAGE M.Ai33
3--53--005&,044
SITE AND BUILDING I
NFORMATION
1,11N=1.211
Department or Planning and Development
City or Seattle, WA
APPLICABLE CODES:
2009 International Residential Code,
International Fire Code,
International Mechanical Code
01190013B5
ZONING: SP1200
OCCUPANCY: No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPEt No Charge)
V B NON SPRINKLERED
LEGAL DESCRIPTION:
THE SOUTH HALF OF LOT 3 AND ALL OF LOT 44, f BLOCK 1 AL ENTOLIN ADDITION, ACCORDING TO THE PLAT THEREOF
RECORDED IN VOLUME 12 OF PLATS, PAGE 100, IN KING COUNTY, WASHINGTON. SITUATE IN THE CITY OF TUKWILA COUNTY
OF KING, STATE OF WASHINGTON.
'.1•18101111111111011111MIIIIMPOIll
DRAWING INDEX
T0.0 TITLE. SHEET, PROJECT INFO.
41.0 FLOOR PLANS 4 NOTES
A2.0 WINDOW TYPES, SCHEDULE 4 DETAILS
A2.1 DOOR TYPES, SCHEDULE 4 DETAILS
A22 MISCELLANEOUS DETAILS
42.3 WINDOW FLASHING DETAILS
111.0 LEGENDS, SCHEDULES, ABSREv., GENERAL NOTES 4 DWG INDEX
112.0 MECHANICAL PLANS AND DETAILS
E1.0 ELECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING:'COUNTY INTL. AIRPORT:
Sound Insulation progtam.
Kin County International Airport
1211 Perimeter 'Road South
Seattle WA $0108
Ph: 206. 263. eZ”
Fax: 206. 296. 0190
Contactd:Shargri Parker
Sharyn.Parker*Ingcounty.gov
ARCHITECT:
8.11..stamper Architects P.L.L,C.
4000 Delridge Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624.•2111
Fol :200..624. 2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E-mail: Jerrsfamatanper.com
melodyassistemper.com
timesmstempercom
ACOUSTICAL ENGINEER
SSA Acoustics
222 Etruria Street Suite 100
Seattle WA 9810•
Ph: 206.839. 6819
Fax: 206. WS. 0824
Contact: Mohawied Alt Allaoua
E-mail: mohamedessaacoustics.com
MECHANICAL ENGINEER:
The Greenbusch Group
1500 West Nickerson St., Suite 201
Seattle, WA 98119
Ph: 206. 31a 0569
Fax: 206. 318.. 0641
Contact: Dylan Turner
DylanTegreenbusch.corn
ELECTRICAL ENGINEER:
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA $6409.
Ph: 253, 412. 3300
Fax: 253. 412. 3463
Contact: Brent Rollins
E-mail: bcriotreswest.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. 0200
Boston, MA 02114
-Contact: Tim Fenlason,
Cynthia 11'4.0414
E-mail:.C114004JOnesp4tyne.com
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph 206. 232. 5635
Fax: 206. 162. 4180
Contact: Tim Ogden
E-mail: thuogdenspbsenv.com
REVIEVGD FOR.
CODE COMPLIANCE
APPROVED
JAN 11 ?nil
VICINITY MAP (N S)
STRUCTURAL ENGINEER:
Peterson Straits Martinson
2200 6th Ave, Suite 201
Seattle, WA 98121
Ph: 206. 622. 4600
Fax: 206. 622, 0422
Contact Ron Martinson
ronm•pstn-engineerszom
City of Tukwila
BUILDING DIVISION
RECEIVED
erry OF TUKWILA
I JAN '072013
PERMIT CENTER
. . •„••,,•,
:• • . . „ • .... , ... • • • .......
„,„ ............................
......... - • - • • • • • • • • • • • • • • ,
...........• • • • • • • • • • • • • • ••• ....... . „..•
• • • • • • • • • • • • • • • •••• .-•••
•
• •
o
NORTH
S.M.STEMPER
ARCHITECTS
A Profeaaional Limited Liability Company
4000 DELRIII/GE WAY SW
SUITE 200 SEATTLE, WA 96106
(206), 624-2777 FAX (206) 624-2973
4220
0810.03.2227
JUNE 7, 2012
0
z
0
17-7
w
z
0
0
0
z
AIP NUMBER
MPROVEMENTS
›-
0
0
z
u_
0
Lu
3-53-0058-044
0
0
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO,
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
PROJECT
INFORMATION,
DRAWING
INDEX,
DIRECTORY
TO.0
0810.03.2227
SPECIAL NOTES:
NOTES:
L ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL :BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01 11 01 AND 02 82 00 FOR
REGULATED MATERIALS ABATEMENT.
2, LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 0111.01
AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
1B SEMENT
PRIOR TO COMMENCING WITH DEMOLITION
A "pre -demo inspection" is required.
Contractors shall provide documentation that
an "asbestos survey" has been completed. If
needed, abatement procedures per "Puget
ound Clean Air Agency" shall be completed
and documentation of compliance shall be
provided at time of final inspection.
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE T4 -IE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE. SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED..
1. ADD SOLID WOOD BLOCKING AT WINDOWS.
8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION. OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED..
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
11. ALL WORK AREAS SHALL ESE BROOM -CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO(E) SHELVING AS REQ'D AND RE -CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONtNTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,.
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL i3E CONCEALED.
11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
18 INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS SHEETS
15. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL AND WORKING CLEARANCES FOR. THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 PM.
•
I
CLOSET
MEDROOI"
1
15" x 30" EXIST.
ATTIC ACCESS
PANEL
LIVING
ROOM
KITCHEN
A. WEST ELEVATION
B. NORTH ELEVATION
PLAN KEYNOTES
OI DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY.. REF. WINDOW SCHEDULE:'.
CDDEMOLISH EXISTING DOORS), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOORFRAME, CASNG,TRIM, THRESHOLD AND
STORM DOOR REF. DOOR SCHEDULE.
0 INSTALL VENT BAFFLE(S) AT EXISTING ROOF VENTS) IN ATTIC. REF. 3/422 FOR DETAIL.
0 INSTALL VENT BAFFLES) AT EXISTING GABLE END VENT(S) IN ATTIC. REF. 4/422 FOR DETAIL.
O DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF.'I/422 FOR DETAIL COORDINATE WITH
MECHANICAL DOCUMENTS.
g INSTALL THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS.
ACCESS TO SITE AND PARKING
I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR BLOCK ACCESS TO HOMEOU,NER DRIVEWAY.
2$'-3"1
I-
I
L
Ii
. . T1. - - • - �
-_ -
111 1-
I
- -
..I —1
•
---.—,-- .—x —. Y—l-.t-'�`-r
II
•
•
.
-1 1-
1.1
11
-1
L r
• {.
P1
-
--15" x 30" EXIST.
ATTIC ACCE<55
PANEL
• . • . • . . 7 :...1. h1
. .
41• . . . . f=--Zjr 1
- i1 III
• _ _17. h . I
I -
r
L —
•
—
.t. 1 y:� • .
• - .%•` I • " - ..
• •. • .
....... - .. - A •
i
L1—_—i-1 — J--L—f—L.j-_4-1-4— .—
4.1
• - AI' I •
21'-l"
C. EAST ELEVATION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 11
City of Tukwila
BUILDING DIVISION
ifinglat
D. SOUTH ELEVATION
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR
REFER TO DOOR SCHEDULE
EXTERIOR STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STOR1'1
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL.
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
1111111111111
GABLE END VENT BAFFLE RECEIVED
+`+ )F TUKWILA
JAN 0 7 20131
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE Mei iiViaT CENTER
FEATHER TEXTURED CEILING OVER AT A.
MN, OF 24" FROM EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL.
CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
REF. MECH. 4 ELECT.
REF. GENERAL NOTE 11
F----- ATTIC INSULATION
ATTIC INSULATION DAM
SD
INSTALL- BATTERY OPERATED SMOKE
DETECTORS
INSTALL BATTERY OPERATED SMOKE
CARBON MONOXIDE DETECTORS
GAS METER
SOFFIT FOR MECHANICAL DUCTING
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability. Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, IYA 90106
(206) 624-2777 • FAX (206) 624-2073
0810.03.2227
JUNE 7, 2012
F--
0 0
U
0
z
MPROVEMENTS
AIP NUMBER
3-53-0058-044
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
NOTES
A1 .0
0810.03.2227
TYPICAL WINDOW SCHEDULE NOT
ES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN. SECTION 08 80 00, ALL UNLAMINATED GLAZING
PANELS IN. THAT UNIT ARE TO: RE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED. GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING .WINDOW OPENING DIMENSIONS.
8. HOMEOWNER SHALL. MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM, CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
4. F.OR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHIFfp.
DETAIL 'A.' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET
I
HEMMED EDGE I
LEND CLOSURE:
HEAD FLASHING DETAIL TYP.
3" 1' - 0"
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER. PENETRATION
FLASHING.. TYP AT HEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION oF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL. SIDING. AS REQ'D. MAINTAIN
(5) 0OURSNG. PAINT MODIFIED SIDING
TO MATCH (E)sipiNG.
FRE -PRIMED, GALY SWEET METAL
FLASHING W/ END CLOSURE UNDER.
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES :AND. PAINT TO MATCH (E) TRIM.
COLOR TO. BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY.
REMOVE (UP. SIDING FOR
(E) WALL UNDERLAymem
(E) EXTERIOR SHEATHING.
SELF ADHERING
MEMBRANE
TOUCH UP P,AINT, REQ'D
CONTINUOUS
SEALANT, TYP.
INSTALLATION OF NEW WINDOW TRIMS
AND. REATTACI-IMENT OF (E) SIDING TO
WINDOW OPENING FRAMING. LIFT £5)
WALL. UNDERLAYMENT AND INSTALL
WINDOW / NAILING. FLANGE OVER SELF
ADHERING MEMBRANE PENETRATION
PLANING. INSTALL SECOND LAYER. OF
SELF ADHERING MEMBRANE OVER
NAILING ELANa AND LAP UNDER (E)
WALL UNDERLAYMENT: CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL
HEADS.FLUN-I, PAINT MODIFIED SIDING
TO MATCH .(E)SIDING.
(E) 0.10. SID11%*
(V WALL UNDERLAYMEW
(E) EXTERIOR SHEATHING
WINDOW HEAD
SOLID WOOD TRIM
JAMB LINING
SEALANT
SHIM AS. NECESSARY
FILL GAP WI BATT
INSULATION
TOUCH UP PAINT, AS. REAP
CONTINUOUS
SEALANT,
BACKER ROD 4 SEALANT
AcosmAL.4)INp0u)AssgrisLy
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
WINDOW JAMB.
SOLID WOOD TRIM
WD JAMS LNNG
SEALANT
SHIM AS NEcEssimy
FILL GAP W/ BATT
INSULATION
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
REMOVE CE) WOOD SIDING FOR
INSTALLATION OF NEW I.UNDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(5) COURSING. PAINT MODIFIED SIDING
TO MATCH. (E) SIDING
(E) EXTERIOR SHEATHING
(5) LID SIDING
VVINDOVV TYPES
2. 3.
SINGLE HUNG HORIZONTAL. FIXED OVER
OR DOUBLE UN XX -SLIDER SLIDER / FIXED I SLIDER
•
4.
SLIDER I.FIXEP / 5JDER
WINDOW SCHEDULE
WIND. ROOM
NO LOCATION
WIND:
TYPE.
SIZE
x I-1INT./ EXT.
TRIM FINISH
REMARKS
DETAIL
SET
A
5
C
LIVING ROOM
LIVING ROOM
3
BEDROOM I
BEDROOM ....2
F
G
BEDROOM 2
BEDROOM 3
BEDROOM 3
KITCHEN
strro4E.
2
-II" x 4'-I�"
3'-102."
•STAN/STAIN
SAFETY GLAZING REQUIRED
1/421)
STAIN/STAIN
2
4
' K214"
STAIN/STAIN.
;STAIN/STAIN
2
4'-10" x
STAIN/STAIN
SAFETY GLAZING REQUIRED
2442.0
2/420 -
2
41-10" x 2' -II"
STAIN/STAIN
4
51-S" x 2'-10"
STAIN/STAIN
SAFETY GLAZING. REQUIRED
2
31-T x 3`-5"
STAIN/STAIN
2/A2,0
2/A20
21A20
2,-5" 21-S"
STAN/STAIN
REMOVE AND REINSTALL (E) SHUTTERS
2/42.0
2/42.0
(E) VD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASI-IING. Tyr AT HEAD AND .JA5.
REMOVE (E.) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY MD TRIM. REPLACE OR RE
INSTALL SIDING AS WO). MAINTAIN
(E) COURSING. PANT MODIFIED SIDING
TO MATCH (5) SIDING.
PRE -PRIMED, GALY SHEET METAL
FLASHING WI END CLOSURE. UNDER
SELF -ADHERING MEMBRANE COLOR TO
BE SELECTED IN. THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (EY TRIM.
COLOR TO SE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WNpoW ASSEMBLY
REMOVE (E) WD. SIDING FOR
(E) WD. PANELING
(E) EXTERIOR SHEATHING
SELF-ADHERNG MEMBRANE
CONTINUOUS
SEALANT; nr.
SOUP WOOD TRIM
wD, JAMB LINING
INSTALLATION OF NEW WINDOW TRIMS
AND REATTACHMENT OF .(E) SIDING TO
WINDOW OPENING FRAMING. LIFT (5)
WALL UNDERLAYMENT AND. INSTALL
WINDOW / NAILING FLANGE OVER SELF
ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER
NAILING FLANGE. AND LAP UNDER (E)
WALL LNPERLAYMENT. CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL
HEADS •FLUSH PAINT MODIFIED SIDING
TO MATCH (5) SIDING
(5) (UP. SIDING
(E) WALL INDERLAYMENT
(E) EXTERIOR. SHEATHING.
13A0KER ROD 4 SEALANT
I I
WINDOW HEAD
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WIND= NAILING FIN
WINDOW JAMB
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (5) TRIM.
COLOR TO SE FIELD DETERMINED
REMOVE (E) Woo SIDING FOR
Ii
1
IT
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PANT MODIFIED SIDING
TO MATCH (5) SIDING
(g)5xTERt.oR SHEATHING
(E) WP. SIDING
{LA
3"
WINDOW SILL
(5): UA PANELING
CONTINUOUS
SEALANT, TYP.
•.SOLID wool, TRim
WP JAMB LINING
SEALANT
SWIM AS NECESSARY
FILL GAP W/ BAIT
INSULATION
3/4"
BACKER ROD 4
SEALANT
3/4" WOOD SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, 'rrP.
SELF -ADHERING
MEMBRANE
(5) WD. PANELING
WQQD SIDING - WINDOW DETAIL, SET
37 = -
j I
BACKER ROD 4
SEALANT
3/4" WOOD SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
TOUCH UP PAINT, AS REQ'D
SELF -ADHERING
MEMBRANE
I
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 11 ?nil
City of Tukwila
BUILDING DIVISION
WINDOW SILL
br
G - WINDOW DETAIL SET
RECEIVED
CITY OF 11 !MU
JAN 07 2013
smsTEmpER
ARCHITECTS
A Professional Limited Liability Company
4000 DEL,RIDGE WAY SW
SUITE 20:0 • SEATTLE, WA 98106
(206) 624-2777 • FAX. (206) 624-2973
0810.03.2227
JUNE 7, 2012
MPROVEMENTS
AI P NUMBER
3,53-0058-044
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.2227
DOOR TYPES
4:
FLUSH SCW EXTERIOR
Wf WAGONUJWEEL SINGLE LEAF STOW
AND 4 PANELS W/ SAFE1T GLAZNG
Wi SAFETY GLAZING
U)/ OBSERVATION PORT
DOOR SCHEDUL
E
DOOR
NO
ROOM
LOCATION
DOCR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET 1 FINISH
KNO
B / LEVER.
SET
LOCK DETAIL
SET SET
•'.LIvING" ROOM
A
2'4" KV -8"
STAIN/ STAIN 1 -1U,1;1 -643.E/1*
PK -4 •
1/42.1
2
a
KITCHEN
x
STAIN/ STAN HW -1 -643E/116
DK -3
LOCK -1 lfA2.
LIVING ROOM
2,4" *7:6."1-i0
1/42.1
4
KITCHEN..
8
x Gt-s"
1/42.1
(E) Vip ,-51p1140
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF-ADPERING MEMBRANE
FENETRaloN FLASI4ING. LAP (E) WALL
UNDERLAYMENT ovER PENETRATION
FLASRING. Tr* AT 14EAD4 JAMS&
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW DOOR ASSEMBLY
AND TRIM. REPLACE OR FS INSTALL
SING REott MAINTAIN (E)
couRsiN4 PANT MODIFIED SIDING TO
MATCH (E) SIDItsa
PRE -PRIMED, GALv SHEET METAL
FLASHING W/ ENP CLOSURE UNDER
SELF-ADHERNG MEMRANE. COLOR TO
SELEC1ED IN THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER So-EMILE
2" tlINI.
REMOVE (E)L. . sipilsioyFoR INsTALIATIoN
OF NEW DOOR TRIMS AND: REATTACI-IMENT
OF fp SIDING TODOOR OPENING FRAMING.
LIFT WALL UNDERLAYMENT ANO WALL
SELF .ANERING MEMBRANE PENETRATION
LASHING. INSTALL SECOND LAYER OP
'SELF :AOHERING.MEMRANE :MP, LAP
UNDER tEAVALL WOERLATMEW. CAULK
NEW VERTICAL SING JONTS 4 SET NAIL
14gApS,P4.014, FAINT"moolFIEo WING TO
MATCH tE)'•
(E) WOOD SIDING
coNTINUMS SEALANT BEHNIP
Z BAR FRAME
KERF AS REQUIRED• FOR WEATWER
STRIPPING INSTALLATION
CONTINUOUS WEATHER -MIFFING
JAM ErroNo
w000 DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE &JEEP
EXISTING FLOOR STRUCTURE
DOOR HEAD
1
SELF-ADHERIN*
MEMBRANE
(E) EXTERIOR 81-1EATI-ING
TOUCH UP PAINT AS, REGVIP
CoNTNUMS
SEAI_ANT, rrp.
soLlo W��P TRim
SWIM AS NECESSARY
FILL GAP UP BATT
INSULATION
WOOD FRAME
KERF45REQUIRED FOR
WEATHER STRIFPNG
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
(E) ExTER1OR 51-EATHING
TOUCH UP PAINT, AS REGI'D
CONTINUOUS
DOOR JAMB
DOOR. SILL
SEALANT, TYR.
.ExISTNG FRAMING
SOLID WOOD TRIM
51-111 145 NECESSARf
PILL GAF LW 5ATT
NsuLATIoN
Dom PER SCI-IEDULE
WOOD DOOR DETAIL SET
= - 0"
TYPICAL D09R. SCHEDULE ',NOTES
1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED. IN.
SECTION:08:80 00, ALL UNLAMINATED GLAZING, PANELS IN THAT
UNIT ARE TO BE TEMPERED.. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED:GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING.PER CODE,
2. SLIDING GLASS DOORS SHALL MATCH. THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3, FIELD VERIFY ALL EXISTING DOOR OPENING. DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINIA.L.FINISH S.ELECTIONS, FOR DOORS
AND INTERIOR/ EXTERIOR. WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK.
5, FOR HEAD FLASHING INSTALLATION REFER TO HEAD. FLASHING
DETAIL 'A'. ON DOOR TYPES, SCHEDULES & DETAILS SHEET.
SLOPE
a
1" min.
4.
HEMMED EDGE --1
LEND CLOSURE
HEAD FLASHING
3" = 1' -
b.r3
DETAIL TYP.
FOR
CODE COMPLIANCE
.• APPROVED
JAN 1 1 lni1
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
JAN 0 7 2013
pERUT CENTEP
S•MST EMPER
ARCHITECTS.
A Prafessiorkal Limited Liability Company
4000 DELI WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-297a
coTT TEMPE?.
STATE
0810.032227
JUNE 7, 2012
0
0
Ce
—J
0
LL1
z
0
AIP NUMBER
MPROVEMENTS
>—
w
w
ct
w
3-53-0058-044
z
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
Jo
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03,2227
(E) GUS
CAREFULLY LIFT (E) WALL UNDERLAYTIENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF VENT FIXTURE AND
FLASHING. REPLACE OR RE INSTALL
SIDING AS MOD. MAINTAIN (E)
COURSING. FAINT MODIFIED SIDING TO
MATCH (E) SIDING.
PRE -PRIMED, GALY. SHEET METAL
FLASHING WI MEND CAPS UNDER
SELF-ADHERING,MEMBRANE.:00EN0
FLASHING 4" UP 04.44, PAINT COLOR TO
BE SELECTED IN THE FIELD
PAINT VENTILATION FIXTURE,
COLOR TO BE SELECTED IN
THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. set IN MASTIC AT
EXTERIOR TRIM.
REMOVE I REPLACE SIDING AS
REQUIRED.
AIR INTAKE D
3" = 1' - 0"
Jr-2X2CNINUI,PRSPRESSURE
TREATED 4 SIDES
seLF 41,14ERNG tlEfril5WitgE
(E) EXTERIOR SHEATHING
E AIL AT
EXISTING ROOF VENT
EXISTING ROOF
STRICTURE
CROSS SECTION
2X BLOCKING
EXTERIOR.
EXISTING VENT COVER
EXISTING ROOF
STRUCTURE
NEW 2"X .SPACER AS
REQUIRED TO PROVIDE
6" CLEAR AIR SPACE
NEW VX SPACER
LATERAL SECTION
ROOF VENT BAFFLE
" MIN. TYPICAL TOP
BOTTOM
NEW in INSULATION BOARD
GLUED TO NELLJ 3/40
EXTERIOR GRADE
PLYWOCPP,
DETA
IL
1 1/2" = 1' - 0"
DUCT
ci-FASE
ANCHOR CEILING NAILER
TO (E) RESILIENT
CHANNEL ONLY. DO NOT
ANCHOR TO JOIST
WHERE WIOTI4 OF SOFFIT
DEMOLISH (E) GWEI
NOTCH TOP PLATE AND TRIM STUDS
OF PARTITION AS REQ'D TO ACCOMMODATE
PASSAGE OF MECH. COMPONENTS. WALL
PENETRATIONS SHALL BE CUT FULL SIZE
OF SOMIT AREA, TYPICAL
2x BLOCKING BETWEEN STUDS
WHICH REQUIRE TRIMMING
EXCEEDS IS", INSTALL 2X4 •
STUDS * 16" O.C.
J -METAL EDGE AND
CAULK JOINT
2x2 coNt NAILER
IS" as PAINT TO MATCH (E) TEXTURE 4
COLOR OF CEILING.
ENCLOSE DUCTS TIGI-ITLY, OIR TEWINATE
EDGE W/ ADJ. ARCHITECTURAL FEATURES
PER PLAN. COORDINATE SOFFIT DIMENSIONS
WITH MECHANICAL
(E) U.JD FRAME WALL ASSEMBLY
EXISTING ROOF
(E) ROOF FRAMING
(E) EAVE VENT
BLOWN IN CELLULOSE
INSULATION WITH A COMBINED
VALUE OF NOT LESS THAN
R-50
INSULATION. DAM
EXIST, WALL:
CONSTR
0/ SIMPSON A-34
fa EACH SIDE PANEL
opEN TOp
EXIST. GABLE
vENT
NEW in GALV.
HARDWARE
CLOTH
cr,x nnuoor,
AT (3) SIDES
I" OWENS CORDING '103
INSULATION, TYPICAL.
SECURE WITH PIN TYPE
FASTENERS TO PLYWOOD
SACK AND SIDE PANEL
(E) WALL FRAMING
NOTE:
1. AFTER FABRICATION, BAFFLE SHALL BE SECURELY
ATTACHED IN POSITION.
2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS
THE EXISTING VENT OPENING.
GABLE END VENT BAFFLE DETAIL
1 1/2" = 1' - 0"
CEILING
4"MIN
BEST HERE
ACCEPTABLE
HERE
NOTE:, REMOVE EXISTING SMOKE
DETECTORS, CUT AND PATCH cEILING, AS
REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND
TEXTURE AND PAINT TO FILL ALL HOLES
LEFT FROM EXISTING CONDITION. PAINT'
TO MATCH SURROUNDING iCONDITIONS.
SMOKE DETECTOR
3" = 1' - 0"
SIDE WALL
REVIEWED FOR
CODE COMPLIANCE
APPROVED
'JAN 1 1 7nii
•
City of Tukwila
BUILDING DIVISION
bt3i%•-oosot
NSTALLATION DETAIL
RECEIVED
CM OF rumAnut
I JAN .0 7 2013
Peourrtan-Eg.
S.MSTEMPER
ARCHITECTS
A Profeasional Liraited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, IVA 98106
200) 624-2777 • FAX (206) 624297.3
0810.03.2227
JUNE 7, 2012
0
z
z
UI
z
0
0
AIP NUMBER
MPROVEMENTS
›0
UI
UI
UI-
3-53-0058-044
0
z.
DATE
JUNE 7, 2012
ISSUED
100Y0 CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
M L & TF
DRAWN.
LB&CF
MISC.
DETAILS
A2.2
081
0.03.2227
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SI-IEATI-IING AT JAMBS
AND HEAD
!BUTTERFLY
CORNERS, TYP.
NOTE:
1
•
REMOVE (E) SIDING. SACK PROM (E) RO. AS REQ'D
(s) SiDima NOT SHOWN • FOR CLARITY. REPLACE AND
OR INSTALL NEW SONG AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
(E) SHEATHING
CUT SILL
FLASHING 4 FOLD
THROUGH R.O.
SHOUN.
LAP SILL MEMBRANE
FLASHING 2-1/2"
OVER (E) BLDG.
PAPER AT SILL.
EXTEND I i" 8EYcND
RO. AT EA. END OF
SILL
(E) BLDG.
PAPER AT
SILL
ADHERE
MEMBRANE
FLASHING. TO
OUTSIDE FACE
OF WALL
SHEATHING
-41/2" TYP.
MEMBRANE F LASH
NO AT Si L
L
'BUTTERFLY COWER FLASHING
SCALE: NTS
LIFT (E) 1SLPG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING Al
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM CE) RO. AS REM"
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE. FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE.
NAIL HOLES. REMOVE
EXCESS MATERIAL
DO NOT SEAL FLANGE
AT WINDOW SILL
CE) BLDG PAPER
AT SILL.
;
ELEVATION VIEW
NOTE: INSTALL WINDOW KIR tIFG'RS SPECIFICATION&
NOTIFY TECHNICAL •REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE I
NISTALLATION
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
•OPENINGS,
BEND
ANCHORAGE
NAILS DOU.N
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
SCALE: NTS
NOTE:. REMOVE tE) SIDING BACK FROM (WIRD. AS REM,
(E) SIDING. NOT SHOWN FOR CLARITY. REPLACE AND
REMOVED OR INSTALL NEW SIDING AFTER •MEMBRANE FLASHING
EDGE OF (E) HAS SEEN INSTALLED.
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT WOLIN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
WHERE REQUIRED,. TRIM
(E) BLDG PAPER AT
HEAD. TO PREPARE
FOR INSTALLATION. OF
HEAD.FLASHING AND
WINDOW TRIM
(FOLLOWING STEPS).
HEAD FLASHING PREPARATION
SCALE: NTS
(E) BLDG. PAPER
NOTE; REMOVE (E) SIDING BACK PROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1 -IAS BEEN INSTALLED.
1/211 1'YP.
MEMBRANE FLASHI
CUT JAMB FLASHING
FOLD AROUND• WINDOW
OPENING AS SHOUkl.
EXTEND I-1/2" BEYOND
EDGE OF O'PENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING.
NG AT JAMB
SCALE: NTS
NOTE: REMOVE (E) alma BACK FROM (E) RO. AS RE=
(E) SIDING NOT SHOUN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
•,••••41.-.
\,,
an_rtr,
- INSTALL JAMS FLANGE FLASHING OVER WINDOW
NAILING. FLANGE AND FLASHING.
QMEMBRANE FLASH
SCALE: NTS
INSTALL SW. METAL
HEAD FLASHING
UNDER CE) BLDG
PAPER
NG AT JAMB
NOTE: REMOVE () SIDING BACK FROM (5) RO. AS REM,'
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS SEEN INSTALLED. ALLOW VS" CLEARANCE
m7," Aicww- •77.1.7
SEMEN FLASHING AND
Ace,
TBOT, EDGEZING(E)
zara /karma fa
TRIMMED EDGE
OF (E) SIDING,
SHOLLN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY,
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
EM B RANE
FLASHING AT HEAD
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOUJN. EXTEND
I-1/2 BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
uJALL SHEATHING
(TYP. EACH SIDE
OF WALL)
SCA
E: NTS
NOTE: REMOVE (E) SIDING BACK FROM. tE)RO, AS REQ'D
(E), SIDING. NOT SHOLIN FOR CLARITY. REPLACE AND
OR INSTALLNEWSIDING AFTER;MEMSRANE:FLAWNG
HAS SEEN INSTALLED:
\
It
,,,,,,,,,,,, •
/-
0
9
IN FLASHING
SCALE: NTS
—J
NSTALLATION
SHEET METAL HEAD
FLASHING
....... ..... .
, •
(E) SIDING
(E)13LDG. PAPER
BENEATH SIDING
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMER EDGE
OF (E) SIDING, APPLY
SEALANT BEAD TO.
JOINT BETWEEN WINDOW
TRIM AND. S1DNG.
WOOD TRIM
SCALE: NTS
INSTALLATION
LEAVE 1/4"-3/6" GAP
BETWEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
I: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS
"SELF ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2; DETAILS "1, 2, AND 3" REFER TO MEM1BRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
S: DETAILS "5 AND 6" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCI-IOREP,
4; DETAILS ""I AND 5" REFER TO SWEET METAL HEAD
FLASHING.
5: DETAIL S REARS TO Wm TRIM MD CAULK
JOINTS..
b t
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 1
City of Tukwila
BUILDING DIVISION
CIECEIVID
CITY OF r ono,' if
I JAN 0 7 2013
PereisT
CI f
S.M.S.TEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
E•RECIS:•FTRIE:11.:,
• .
0810.03.2227
JUNE 7., 2012
z
LLI
KING .COUNTY
AIP NUMBER
MPROVEMENTS
›—
Lu
2
LU
ct
ci)
0
LL
UI
0
Cf)
UI
ce
3-53-0058-044
0
F-
0
z
DATE
JUNE 7, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
FLASHING
DETAILS
A2.3
081
0.03.2227
AE3BREVIATIONS
LEGEND
DRAWING
INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASH RAE
BFC
BFF
BOD
BTU
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MEG
NC
NIC
N FPA
NG
NO
N TS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
•SA
SEC
SG
SHT
SM
SMC
SO
. P.
SPEC
SRC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS:
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING.
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN:. SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW. FINISHED CEILING'
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR:
CEILING DIFFUSER
CUBIC FEET PER miNuTE,
CIRCULATING
CONDENSATE'
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING .AIR TEMPERATURE
EXHAUST - GRILLE:
EXTERNAL 'STATIC PRESSURE:
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS; ANo. DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING,. VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER 'CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT,: (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE.
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED.
NOT IN CONTRACT
NATIONAL FIRE PROTEC11ON, ASSOCIATION
NATURAL ..GAS
NORMALLY OPEN
NOT TO :SCALE.
OUTSIDE AIR,
OUTSIDE AIR. TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN. GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY ,D1FFUSER.
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
SEATTLE ,RESIDENTIAL CODE
TOTAL DYNAMIC HEAD -
TOP OF DUCT'
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT,: VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY N
OT CONTAIN ALL ABBREVIATI
ONS LISTED
SYMBOL
ABBE
OR ZX
0
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICA
L FLOOR PLANS AND D
ETAILS.
GENERA
L NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ,ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING,TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED.. :PROVIDE: A COMPLETE AND OPERABLE MECHANICAL:
SYSTEM ;COMPLETE: WITH ALL MECHANICAL WORK .AS REQUIRED, FOR SYSTEM OPERATION.
2. THE DESIGN. OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE mANUFACTURERS, LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT .NAMED IN THE SPECIFICATIONS,
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE. TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND,: GUARANTEE IN WRITING THATNOADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING'EQUIPMENT, DO NOT SCALE FROM PLANS...
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9
REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
PROVIDE6.
ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS,
8.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4"-0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10.-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
HANGERS,
SYMBOL
XXX
AMR
4,E
><1
0
OR
EQUIP
EQUIP
NC -
0
• I I I • • .gm •
4ff A
DNI
UP.
VO
RA/EA
RG
SA
SA
RA/EA
SD
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR Ain
DUCT W/ INSULATION
ALTERNATE DUCT
C
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR'GRILLE.
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
MOD
NG
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL/ELECTRICAL COORDINATION
ITEM
NO.
E.QUIPMENT
CONTROL EQUIPMENT
DE S CRIPT1 ON
VOLTS
PH
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED.
UNDER DIVISION
2.3
26.
23
26
N/A
23
2.6
N/A
REMARKS
MOTOR OPERATED DAMPER
24
X
1,2
THERMOSTAT
•24
X
X
X
REMARKS:
I - VERIFY QUANTITY FROM PLANS (TYP CAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDU
E
MARK
LOCATION
•CF M
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
REMARKS
WC -1
EXTERtoR:
90
337
<.08"WG
7"0
1,2
REMARKS:
I. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
(SQ. FT.)
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03- 2227
772
3
90 CFM
90 CFM
I. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE :(WAC),
SECTION 51-51-1508, TABLES MI508,2 AND M1508,3
DUCT LOCATION
MINIMUM DUCT INSULATION THICKNESS
. „ . . . .MIIN VALUE•
NOTES._
ON ROOF OR ONEXTERIOR:OF BUILDING
R-8 WITH WEATHERPROOF BARRIER
ATTIC. GARAGE, CRAWL. SPACE, IN WALLS. IN FLOORiCEILING
R-8
I ..3
12,3.
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R-8
1,3
IN CEMENT SLAB OR IN GROUND
R-5
1,3
NOTES:
I. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT iNCLUDING FINISHING MATERIALS,
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR.
3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.,
DRAWING
ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE: EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR To
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES, THE CONTRACTOR SHALL IDENTIFY;
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 011101 AND 028200 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED
TO EXTERIOR WINDOW TRIM PAINT.
THERMOS AT/SWITCH HOURS OF OPERATION
SET THERMOSTAT/SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
MECHANICAL VENTILAT
ON
CALCULATION.
PER WAC 51-51 M1508.3:
QF = QR / (&EGR X F)
QR = (FROM TABLE M1508.2) 45.
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF 4-5 / (1 X 1/2) = 90 CFM
8eP 1.0
PEppi: vire
Ap MINA,
ReQPROkeiV°
1110
ED
RECEIVED
OW OF TtomI,A
(JAN ,0 7 2013
PERMIT C.ENTEP
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional Molted Uabillky Company
4000 DELRIDGE WAY SW
SUITE 200 • sums. WA 0E1100
(006) 624-2777 • Pa (200) 624-2102
TEE GREENBUSCH GROUP, INC
•)))6.006•66
:coupriati,200 .378.43586,fix40 VIDEO 6 118211220/0010 3707:47. FAx60
000 Mr 112102IS0N 0E21 SINE 201 SEVITIE, 001110
IMPROVEMENTS
T NOISE REMED
AIR NUMBER
S-53-0058-044
DATE
06105/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO.
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M
0810.03.2227
LOWER FLOOR MENA
SCALE: 1 /4"
NICAL PLAN
Ld
FURNACE
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
JOIST PER PLAN
VOLUME DAMPER FOR
'i EXISTING RETURN DUCT.
FIELD VERIFY SIZE
PRIOR TO ORDERING
z.
rt
LLI
w
MOD, INTERLOCK
TO FURNACE
FLOOR.
NORTH
SEE
ROOM
SO' EXIST.
ATTIC ACCESS
PANEL.
LIVING
ROOM
(E)RS
MAIN FLOO
SCALE: 1/4" = 1 —0
SHEETMETAL
TRANSITION TO WALL
CAP NECK SIZE
R
MECHA
N
!CAL PLAN NORTH
DUCT PER PLAN
CAULK
2X: BLOCKING
NOTES:
•2X BLOCKING
FOAM BACKER
ROD
WALL CAP
•SLEEVE AND
ESCUTCHEON
WALL
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORD. WARCHITECTURAL TECHNICAL DOCUMENTS,
REF. 1/A2.2 FOR DETAIL.
�WALL CAP DETAIL
SCALE: NONE
DRAINING: NQTES;
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR
3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51,
SECTION M1508.5.4.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE
TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT
LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY
THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51-51, SECTION M1508.5.2
(CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF
OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER
ENERGY—CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH
PROJECT REP RESEN TATIVE.
4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK—OUT WORK HAS BEEN
COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE
FOLLOWING:
A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR
UNIT SYSTEM (S) WITH NEW FILTERS.
FLAG.
NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO
ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE WSEC 1412.4 COMPLIANT
THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS
"WHOLE HOUSE 'VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC
51-51, SECTION M1508.5.2,
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET
OF FURNACE RETURN INLET PER WAC 51-51, SECTION M1508.5.1.
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE
RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE
OUTSIDE/RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR.
FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING, IF A VOLUME
DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED.
(r)
13.
SEPARATE
APPRov
PERMIT AND
AL
REQUIRED
RECEIVED
CITY OF TUKWILA
I JAN 0 7 2013
PERMIT CENTEP
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
Protemional Ihraites0 Likb1114, Mammy
4000 0ELR.,IDGE WAY. SW
SPITE 200 • SEATTLE, WA 98100
(no 634^-0777 ^ PAZ (806) 024-2978
THE GREENBUSCH GROUP, INC
• 0 • 0 0 0 *0
griCA4WEST AU1112111030‘4° SIVIET 11ITE 201 MU Ilk 011
(201) 378-0582 (208) 370-01141 FM
CJ
CN
cD
co
co
0
ct
co
w
AlP NUMBER
3-53-0058-044
PATE
06/05/2012
ISSUE)
100% Cp.
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
4A, DT
MECHANICAL
FLOOR PLANS
AND DETAILS
M20
Oa -10.012M
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD..
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION, OF ELECTRICAL DEVICES., SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
5. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM .Sc, AFTER
5:00 pm,.
4. WHERE NEW ELECTRICAL .EQUIPMENT OR DEVICES REPLACES QasilNq, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PRoyiDE.
SHEET 'ROCK. TAPE AND TEXTURE AND PAINT .TO, FILL ALL. HOLES LEFT FROM EXISTING CONDITION OR.: NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.,
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDI110N.
PAINT TO MATCH SURROUNDING CONDITIONS,
ELECTRICAL PLAN NOTES
O PROVIDE CONNEC110N FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE
0 PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS
O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH.
el -ORAL -1E
TO MUM
PotlEft SLIMY
7
IHNJORTH
E3EDROOM
2
CLOSET
5E LD t'001-1
3
EE D ROOM -
Li
/,,,
,
f.
I. .1.
1' x.. " --.'F. /
ATTIC ACC:ES:5
L I VNC.,
ROOM
Li
L
TO FLIPIACE
1,14.1FER
r-
TTh
ELECTRICAL LEGEND
SYMBOL DESCRIPTION
SYMBOL
DESCRIPTION
UGHT1NG OR POWER PANEL
Ink
0
BRANCH pRcurr.WIRINO AND. coNDDIT.,A.$:REDDIRED FOR. VIM DEVICES -
AND EQUIP INDICATED ON PLANS, (WIRING AND CONDUIT :SIZE MAY NOT -
APPEAR ON -PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE
#12 AWG, MIN EMT OR RIGID STEEL 1 INDICATES EQUIP GND,
INDICATES ISOLATED GROUND.
MAST, WEATHERHEAD
BRANCH CIRCUIT HOME RUN
EQUIPMENT coNNECTioN, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
DAMPER CONNECTION
NON-FUSED DISCONNECT SWITCH
[al
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
SMOKE DETECTOR
[al
ELECTRICAL METER
11MER OPERATED SWITCH
AERIAL SERVICE CONDUCTORS, COORDINATE WIN UTIUTY.
CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT
THERMOSTA
C41 UNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR
MAIN FLOOR PLAN
I/4" = 1'
MECHANICAL / ELECTRICAL COORDINAT
ION
EQUIPMENT
NO.
CONTROL EQUIPMENT
DESCRIPTION
VOLTS
PH
FURNISHED.
UNDER DIVISION.
INSTALLED -
UNDER DIVISION
WIRED
UNDER DIVISION
MOTOR OPERATED DAMPER
24
1
15 16
X
15 16 N/A
X
15
16
N/A:
REMARKS
X
THERMOSTAT
24-
1
X
X
X
1
REMARKS:
1 - VERFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
LI
I
— — —
LL
rf
• —
4T CCES5
jJ
L
Li
Li
L_
7
L
1)13-0044t
SEPANT
*/#
PERkir E
AND
RECEIVED
CITY OF ruovvi
1JAN 07 2013
oerima awl
SJOTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA NM
(am) 624-2777 • FAX (206) 824-2973
0810.03.2227
NTERNAT1ONAL AIRPORT
CO
z
w
w
›-
w
w
w
CO
z
0
z
w
0
CI,
AIP NUMBER
5-53-0058-044
SEATTLE WASHINGTON
DATE
JUNE 7, 2012
ISSUED
100%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
El .0
0810.03.2227