HomeMy WebLinkAboutPermit D13-010 - FASANO RESIDENCE - REMODELFASANO RESIDENCE 12029 44 AV S D13-010 Parcel No.: Address: Suite No: Project Name: City St Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov 3347400450 12029 44 AV S TUKW FASANO RESIDENCE DEVELOPMENT PERMIT Permit Number: Issue Date: Permit Expires On: D13-010 01/1S/2013 07/14/2013 Owner: Name: Address: FASANO MARK P 20208 SE 245TH ST , MAPLE VALLEY WA 98038 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RDS , SEATTLE WA 98108 Contractor: Name: G & G SPECIALTY CONTRCTORS INC Address: 4633 S 36 ST , PHOENIX AZ 85040 Contractor License No: GGSPEGS919RT Lender: Name: Address: Phone: 206 296-7437 Phone: 480-921-4079 Expiration Date: 12/31/2013 DESCRIPTION OF WORK: RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE - WORK TO POTENTIALLY INCLUDE SELECTIVE REPLACEMENT OF WINDOWS, SELECTIVE REPLACEMENT OF INTERIOR/EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS, INSTALLATION OF SECONDARY SLIDING GLASS DOORS AND SKYLIGHTS, ETC. Value of Construction: $38,918.00 Type of Fire Protection: Type of Construction: VB Electrical Service Provided by: SEATTLE CITY LIGHT Fees Collected: International Building Code Edition: Occupancy per IBC: $1,313.36 2009 0022 **continued on next page** doc: IBC -7/10 013-010 Printed: 01-15-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: N N Water Main Extension: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and ex governing this work will be complied Number: 0 Start Time: Volumes: Cut 0 c.y. Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: Private: The granting of this permit does not pres construction or th.e_nerformance of work. to this permit. Signature: Date: Public: Non -Profit: N Public: this permit and know the same to be true and correct. All provisions of law and ordinances ether specified herein or not. to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit and agree to the conditions attached Date: l '' S — Print Name: CJ Ol eed Thisermit shall become null and(void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended P Y P or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDMONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All wood to remain in placed concrete shall be treated wood. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary doc: IBC -7/10 D13-010 Printed: 01-15-2013 sewer connections, and properly fill or of se protect all basements, cellars, septic twells, and other excavations. Final inspection approval wi determined by the building inspector base satisfactory completion of this requirement. 8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. .. • 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D13-010 Printed: 01-15-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. t -M--01, 0 Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 12029 44th Ave. S. Tenant Name: Mark Fasano King Co Assessor's Tax No.: 3347400450 Suite Number: Floor: New Tenant: 0 Yes ® ..No Property Owners Name: Mark Fasano Mailing Address: 20208 SE 245th St. Maple Valley WA 98038 City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296-7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker@kingcounty.gov City State Fax Number: (206) 269-7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody@smstemper.com or tim@smstemper.com City State Day Telephone: (206) 624-2777 Fax Number: (206) 624-2973 Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H:\Applications\Forms-Applications On Line\2009 Applications \I-2009 - Permit Application.doc Revised: 1-2009 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ X31,403' "JlJ 1-1 « Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes O.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm m None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2 " x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On Line\2009 Applications NI -2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 1,503 2nd Floor 688 3'd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm m None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2 " x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On Line\2009 Applications NI -2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 PLUMBING AND GAS PIPING PERMIT INFORMATION — 206-431-3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen (>750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets . H:\ Applications\Fonns-Applications On-Line\2009 Applications \I-2009 Permit Application.doc Revised: 1-2009 bh Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 Intemational Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE Signature: AU ' 0'7 GENT: Ampummew Print Name:mothy J. Fen := on temper Architects, PLLC Day Telephone: (206) 624-2777 Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Date: V/7//5 City State Zip Date Application Accepted: o{ 191 I I,e, Date Application Expires:01 I OI I n Staff Initials: H:Wpplications\Fomu-Applications On Line\2009 Applications\I-2009 - Permit Application.doc Revised: 1-2009 bh Page 6 of 6 • City o T'ukwilar Department of Community Development 6300 Southcerter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: hlin:/ivww.ci.ndnvila.wa.US SET RECEIPT RECEIPT NO: R13-00124 Initials: JEM Payment Date: 01/09/2013 User ID: 1165 Total Payment: 13,045.45 Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE) SET ID: S000001897 SET NAME: KING COUNTY NOISE ABATEMENT SET TRANSACTIONS: Set Member Amount D13-004 1,018.34 D13-005 1,239.61 D13-006 1,313.36 D13-007 779.67 D13-008 1,116.68 D13-009 1,141.27 D13-010 1,313.36 D13-011 1,092.10 D13-012 1,239.61 D13-013 1,092.10 M13-003 167.70 M13-004 186.50 M13-005 177.10 M13-006 167.70 M13-007 177.10 M13-008 177.10 M13-009 124.25 M13-010 177.10 M13-011 167.70 M13-012 177.10 TOTAL:4— 119, 0qC • 1-F;�_ TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 13,045.45 TOTAL: 13, 045.45 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES 000.322.100 6,849.15 City c Tukwila, Department of Community Development 6300 Southcerter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: htfi:/tvrvw.ci.tukivi/a.wa.us STATE BUILDING SURCHARGE • 640.237.114 45.00 TOTAL: 13, 045.45 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 _ (206) 431-3670 Permit Inspection Request Line (206) 431-2451 D13-010 Proj cf s •�-ills) lid% i Type f Inspectio7: �� i� A 1 LSO 1 ib: /lam Addrgss:,, 2.1 441 1 f r Date Called: C.,, - ( � Special Instructions: /7.•• Date Wanted —2_,j) j) — J 3 [. rp..mm.. Requester: Phone No: ffApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: t) -e1 WT -7,0'A'4 ...) e r C. e_ » . A Inspector: I I Date 7 •., n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Jennifer Marshall From: Sent: To: Cc: Subject: Tim Fenlason <tfenlason@jonespayne.com> Tuesday, January 08, 2013 11:29 AM Jennifer Marshall sharyn.parker@kingcounty.gov; Jesse Holgate Re: KCIA RANRIP Submittal You are correct. I'd like you to change the applications to reflect the amounts in the pink column. I thank you for this extra work and if you'd like, I can gladly drive to your office to make the changes. On Tue, Jan 8, 2013 at 9:56 AM, Jennifer Marshall <Jennifer.Marshall@tukwilawa.gov> wrote: Good morning Tim, Due to the fact that I cannot just arbitrarily change information on permit applications, I am clarifying the direction you are giving me. Are you directing me to update the valuations provided on the applications submitted yesterday to the numbers below under the column highlighted pink and labeled "Value Originally Provided?" Applicant Name Ochoa Residence Nguyen Residence Aragon Residence Aragon Residence Carter Residence Christensen Residence Fasano Residence Kerr Residence Nguyen/Diem Residence Rivera Residence Address 11863 44 Av S 5016 Wallace St 4610 S 124 St 12245 46 Av S 1180240P1S 12212 48 Av S 12029 44 Av S 3834 S 116 St 11620 40 Av S 11826 44 P1 S Dev Permit Value Provided on No Application D13-004 $24,018.00 D13-005 D13-006 D13-007 D13-008 D13-009 D13-010 D13-011 D13-012 D13-013 $31,135.00 $32,099.00 $17,201.00 $25,472.00 $28,169.00 $37,403.00 $23,133.00 $33,129.00 $23,619.00 Value Originally Provided '. $26,622.00 $35,359.00 $38,407.00 $19,973.00 $30,978.00 i. $31,174.00 $38,918.00 $29,764.00 $35,722.00 $29,761.00 If these numbers are correct please respond accordingly and I place a copy of these emails in the file proving that I have been authorized to make the changes. If they are not correct, please provide me with the correction valuations. Thank you, Jennifer Marshall Permit Technician Original Message From: Tim Fenlason [mailto:tfenlason@ionespayne.com] Sent: Monday, January 07, 2013 4:18 PM 1 To: Jennifer Marshall Cc: sharvn.parker@kingcounty.gov; Bill Rambo; Jesse Holgate Subject: Re: KCIA RANRIP Submittal Jennifer, My preference would be to use the amount provided to Bill and to update the applications. I know that the amounts provided to Bill are correct, as I did those calculations myself. On Mon, Jan 7, 2013 at 4:08 PM, Jennifer Marshall <Jennifer.Marshall@tukwilawa.gov> wrote: > Good afternoon Tim, > I received the applications and plans for ten lots for the above > referenced project. I have completed the data entry in our permit > system and discovered there are discrepancies with valuations provided > to Bill Rambo and the valuations provided on the applications. I have > attached a spreadsheet showing those discrepancies. The issue with > there being a difference is that the permit estimate provided from > Bill is no longer applicable. > It is the end of my work day, so I will wrap this up tomorrow morning > (I probably will not be able to fit it in until about 10 am) and > provide the updated permit fees which will correspond with the new > valuations given. At that point we will need payment to be made > before the permits can begin the review process. I have also attached > the original worksheet you and Bill were working with for your reference. > Have a good evening. > Jennifer Marshall > Permit Technician, City of Tukwila > T: 206 431-3670, F: 206 431-3665 > jennifer.marshall@tukwilawa.gov Tim Fenlason Associate AIA Senior Job Captain 2 *ERNI COORD C0P?`� PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-010 DATE: 01/07/12 PROJECT NAME: FASANO RESIDENCE SITE ADDRESS: 12029 44 AV S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Building Division W - „ gl /f vl . ® 13 Fire Prevention Public Works ❑ Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 01/10/13 Complete Et] Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: LETTER OF COMPLETENESS MAILED: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 02/07/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center. Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Printer Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company G a G SPECIALTY CONTRCTORS INC 4809214079 4633 S 36Th Street Phoenix AZ 85040 Out Of State Corporation G a G SPECIALTY CONTRCTORS INC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602975812 Active GGSPEGS919RT Construction Contractor 12/31/2009 12/31/2013 General Unused Business Owner Information Name Role Effective Date Expiration Date GOODBALLET, CHARLES ELMER Chief Executive Officer 12/28/2009 Bond Amount WAVY, CHRISTINE Chief Operating Officer 12/28/2009 59BSBEA9058 GOODBALLET, JAMES SCOTT President 12/28/2009 GOODBALLET, TERESA LYNN Secretary 12/28/2009 INS CO OF THE WEST Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 HARTFORD FIRE INS CO 59BSBEA9058 12/18/2010 Until Cancelled $12,000.00 01/03/2011 1 INS CO OF THE WEST 2278440 12/18/2009 Until Cancelled $12,000.00 12/28/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 Companion Property a Cas Ins C PCP10000270101 11/03/2012 11/03/2013 $1,000,000.00 11/16/2012 3 National Union Fire Ins of PA PCP1000027 11/03/2011 11/03/2012 $1,000,000.00 12/27/2011 2 LEXINGTON INS CO 4392611702 12/31/2010 12/31/2011 $1,000,000.0001/11/2011 1 LEXINGTON INS 4392611701 12/31/2008 12/31/2010 $1,000,000.0001/14/2010 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 01/15/2013 KI NG COU NTY INTERNAT ONA RAFT NOISE REMEDY FM PROV EMENTS PROGRA SCOPE OF -WORK • RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION AIRCRAFT 'NOISE AND PROVIDE MECHANICAL yENTILATiON. NE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND SPECIFICATIONS INCLUDING 8UT NOT LIMITED TO: APPLICABLE YES NO L SELECTIVE REPLACEMENT OF EXISTING UJINDOWS. WITH NEW VNYL-FRAMED ACOUSTICAL. WINDOWS. 2. CUT CR:X.1N OF UJINDOWS TO COMPLY WITI4 EGRESS REQUIREINTS. x 3. WILL OF EXISTING OPENINGS. x 4. SELECTIVE REPLACEMENT OF MEMOIR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. 5. INSTALLATION OF STORM DOORS 6. INSTALL4I1QNOP SECONDARY SLIDING GLASS. pooRs. 1. INSTALLATION OF SECONDARY SKYLIGHTS. x S. INSTALLATION OF PET POOR% 9. INSTALLATION OF'FIREPLACE MEN+ AIR VENI. 10. NSTALLATION• OF C1 -11E1 CAP. 11. REGULATED MATERIALS ABATEMENT, 12. ATTIC VENT 5AFFLES. 13. INSTALLATION OF ATTIC. INSULATION. 4. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. x 15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSCXIATtp DUCTING. 16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. T. ELECTRICAL MODIFICATIONS TO SUPPORT ARCHITECTURAL MODIFICATIONS. INSTALLATION OF MECHANICAL VENTILATION AND I INSTALLATION OF SMOKE DETECTORS. x I% NEW ELECTRICAL PANEL / SERVICE. 20. -*1018 AND 11.15E WIRING. SEPARATE PERMIT REQUIRED FOR: eMachanicat erElectrical nimbIng Cas Piping City of Tukwila Bt OWING DIVISION FILE COPY Permit No. 10 Plan Irvin approval is subject to errors and omissions. *I Lt;orov, „ Copy : 0 ; •,• • ,= is acknowledged: L...,,,rJony :f construction documents does not authcits n of aadopted code or ordinance. Reccipt By Data: City Of ThIcwila BUILDING DIVISION No changes sREVISIONS hall be made to the scope of work without prior approval of Tukwila Building Division. VOTE: rzvlsions will require a new plan submittal and may include addition& plan review fees. M 0747C12.' .... AIRPORT BI D PACKAGE M-33 • ...3-53-0058044 SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Seattle, WA APPLICABLE CO2 2009 International Residential Code, International Fire Code, International Mechanical Code ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Chang& V 18 NON SPRINKLERED 3341400450 LEGAL DESCRIPTION: LOT 84, 85, AND 86, BLOCK 2, CD. 1-111.1_MAN'S MEADOW GARDENS ADDITION TO THE CITY OF SEATTLE, DIVISION NO. I, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME. 12 OF PLATS, PAGE 64, INKING COUNTY, WASHINGTON. DRAWING I NDEX T0.0 A1.0 A2.0 A22 A23 TITLE SHEET, PROJECT INFO. FLOOR PLANS 4 NOTES WINDOW TYPES, SCHEDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS WINDOW FLASHING DETAILS 111,0 LEGENDS, SCHEDULES, :4515REV., GENERAL NOTES 4 DWG INDEX 112.0 MECHANICAL PLANS AND DETAILS E1.0 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 9810:5 Ph: 206. 263. 9233 Fax: 206. 256. 0190 Contact: Sharyn Parker E-mail: SharynParkerskingcounty.gov ARCHITECT: 5.11..Stempar Architects f.L.L.C. 4000 Delridge Way SW, Suite 200 Seattle, WA 95106 Ph: 206. 624. 2111 Fax: 206. 624. 2813 Contact: Jerry Oebom, Melody Leung, Tim Fenlason, E-mail: Jerryesmstemper.com melodyiemstemper.com timeemsteinper.com . H ACOUSTICAL ENGINEER: SSA Acoustics 222 Etruria Street, Sults 100 Seattle WA 98109 Ph: 206. 839 0813 Fax: 206. 839. 0824 Contact: Mohamed Alt Allaoua E-mail:mohamedassaacoustic.s.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph: 206. 31S, 0569 Fax; 206. 318. 0641 Contact: Dylan Turner E-mail: DulanTegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S 42nd Street SuIte 301 Tacoma, WA 65406 Ph: 253. 412. 3300 Fax: 253. 412. 3463 Contact: Brent Rollins E-mail: bcretreswest.corn REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eaatlalco Ave E., Suite 100 Seattle, WA 98102 Ph: 206. 232, 9639 Fax: 206. 162. 4180 Contact: Tim Ogden E-mail: tim_ogdenepbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. 0200 Boston, MA 02114 Contact: Tim Fenlason, Cynthia Maeda E-mail: CMaedaelonespaynacom STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 20b. 622, 4680 Fax: 206. 622, 0422 Contact: Ron Martinson E-mail: ronmepain-englneer6r-oin VICINITY MAP (NTS) REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 1 2013 City of Tukwila BUILDING DIVISION • RECEIVED cnv or TUKWILA I AN 072013 PERMIT CENTER „..„................... ...............,............... ................................ ................................ ............................... ................................. • .••••• •• AL " • • • • • • • • • • • " 4 NORTH S.M.STEMPER ARCHITECTS A Professional Limited Liability cwnpany 4000 DELIVAGE WAY SW SUITE 200 • SEATTLE, WA 98100 (206) 624-2777 • PAX (206) 624-2973 , . • SIAIT •Of' • ASH NQTr. 0810.03.2228 JUNE 7, 2012 MPROVEMENTS ci) AIP NUMBER 3-53-0058-044 PATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP PROJECT INFORMATION, DRAWING INDEX, DIRECTORY TO.0 0810.03.2228 MAIN FLOOR PLAN 1/4" = 1' SPECIAL NOTES: NOTE: SURPLUS ALL EXISTING WINDOWS AND DOORS TO HOMEOWNER PRIOR TO COMMENCING WITH DEMOLITION A "pre -demo inspection" is required. Contractors shall provide documentation that an "asbestos survey" has been completed. If needed, abatement procedures per "Puget Sound Clean Air Agency" shall be completed and documentation of compliance shall be provided at time of final inspection. GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. THESE 3, HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 ISM TO 6:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS N THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5, DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE: REMOVAL AND REPLACEMENT OF A. DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM: 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TEIRIlITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION I5 UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. S. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11 ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO(E) SHELVING AS REQ'D AND RE -CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11 DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 18 INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TD SMOKE' DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. 15. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POUER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 5:00 AN 4 AFTER 5:00 PM. (E) LUD. BI=NCI-1 CLOSET r BEDROOM 2 1S x 24" EXIST. ATTIC ACCESS PANEL A. NORTH ELEVATION BATH 2 STUDY —o CLOSET BEDROOM B. EAST ELEVATION PLAN KEYNOTES I DEMOLISH (E).WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY.. REF. WINDOW SCHEDULE. 0 STORM DOOR REF. DOOR SCHEDULE. . DEMOLISH EXISTING DOOR(S), FRAME, CASING, TRIM AND THRESHOLD.. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM,THRESHOLD AND 3 INSTALL NEW SECONDARY SLIDING DOOR(5). REF.: DOOR, SCHEDULE. 4 _ INSTALL SECONDARY SKYLIGHT BELOW (E) SKYLIGHT. MAXIMUM AIR SPACE. BETWEEN SKYLIGHTS SHALL .BE 4". VERIFY EXISTING CONDITION/ S AND` NOTIFY TECHNICAL REPRESENTATIVE IF EXISTING CONSTRUCTION DOES NOT ALLOW FOR THIS. REF. 2422 FOR DETAIL. __. R . E L 5 INSTALL VENT BAFFLES) AT EXISTING ROOF VENTS) IN ATTIC. REF. 3/A22 FOR DETAIL. i5 INSTALL VENT BAFFLE(S) AT EXISTINGGABLE END VENT(S) IN ATTIC. REF. 4/A22 FOR DETAIL.. 0. INSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS. S LEVEL OUT EXISTING SILL HEIGHT ATW DOW5 C AND D () REMOVE AND SURPLUS (E) EXISTING A/C UNIT TO .HOMEOtLNER. ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR BLOCK ACCESS TO HOMEOU,NER DRIVEWAY.. 51'-0° HUI Illi --1- ----- :-", -1- -4.-- tII I� 111)311ctd • I. I. 1.4 L...I : ::::::: - -_ - O . . �' ..:Ik.„,.--1..... Ht..il? -L�_ I/• i ... • .... 11.'.. ........... I LI.II I` . I II jliI (. -.. /..-_-.... III _ l6i`X:24 E)CI$T, rI . ATTIC ACCESS •l . - �.-.-- -,' II ..•._ ••�"��-' .�. ” ?.•�...�.j= r •rT'AN1=t-__ • • •LII II • -�� h-..�..: j tf :141877'.'• 4 ThC'! III- II . II/ ...PANEL I(I •' �� '•::..i1E ......ir I IK`.. • .— . ..•- 411.. . I �TI I \ h. .1 i..'11..... f ..........i �� ._ SIII I..... C=D L 2I'-0" r --t"..{1'.'. . I I rj . 1 I.''If...... 2 (E) EXISTING SOFFIT VENTS 2V-10" TVP. ATTIC PLAN 1/8" = 1' C. SOUTH ELEVATION m N REVIEWED FOR CODE COMPLIANCE APPROVED JAN 11 2013 City of Tukwila BUILDING DIVISION a WEST ELEVATION. LEGEND X❑ 4 ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DooR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE. SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE. MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL. FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION. PHOTO VIEW IIIIIIIIIIIII GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE RECEIVED CITY OF TUKWI IJAN 07 201 PERMIT CENTE FEATHER TEXTURED CEILING OVER AT A MK OF 24" FROM EDGE OF PATCHING. £; MATCH (E) TEXTURE AND PAINT .'i :.� ATTIC ACCESS PANEL. CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. 1 REF MECH. t ELECT. :I REF. GENERAL NOTE 11 r------ ATTIC INSULATION. ATTIC INSULATION DAM SD INSTALL BATTERY OPERATED SMOKE DETECTORS SG INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER. SOFFIT FOR MECHANICAL DUCTING. S.M.STEMPER ARCHITECTS A Pratessiona] Limited Liability Company 4000 DELRIDGD WAY SW SUITE 200 • SEATTLE, 1YA 90106 (206) 624-2777 • FAX. (206) 624-2973 O s ?A r•h e4:.1;. % sTATE 0810.03.2228 JUNE 7, 2012 ce 0 a J Z 0 Z W H Z Z 0 0 Z MPROVEMENTS AIP NUMBER 3-53-0058-044 z 0 0z co DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES A1 .0 0810.03.2228 WINDOW TYPES 2. HoRIZoNTAI_ 511'4*LE HUNG xx-SLIDER OR POUI5LE HUNG 3. 4. WIDER / Foe, sECONDARy SKYLIGHT WINDOW SCH EDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE VV x H TRIM FINISH INT./ EXT. REMARKS DETAI L SET A B ',MDT 2 x. STAIN/STAIN SAFETy :GLAZING, REQUIRED I/A2 EIREAKFAST 2, STAN/STAIN SAFErr :GLAZINGREQUIRED I/A2.0 5REAKFAST BREAKFAST 3 x 31-3" STAN/STAIN SAFETY GLAZING REQUIRED 1/420 3 41:45." x 3,4" STAIN/STAN I/A20 E KITCHEN. 2 214" sTAN/STAIN 2/A2,0 F: DINING Rx;t1 DINING ROOM 2 2 4`-e" x 41-01 x 41-3" STAN/VAIN STAN/STAIN PINING ROOM 2 ▪ x 4148 STAIN/STAIN SAFETY GLAZING REQUIRED SAFETY GLAZING REQUIRED SAFETY GLAZING REQUIRED I/420 /420 /42.0: pNNG ROOM LIVING RooM 1 2 4I-5" x•2-1-611 2'41° x 41-10" STAIN/STAIN STAN/STAIN 1/A20, K. L LMNG ROOM L IvING :RO1 LIVING R0011 2 2 2 2141" x.4'440" STAIN/STAIN I/AM STAIN/STAIN STAIN/STAIN 0 R LIVING RDDI, STAIR STUDY BEDROOM 1 BEDROOM KITCHEN 2 2 21-11" x 41-1cp" x 41-4" 41-11" x 41-0" • x 3' -lo" 41-11" x 3,-10" STAN/STAIN STAIN/STAIN sAPErr GLAZING• MOUIRED SAFETY GLAZING REQUIREP SAFETY GLAZING- REQUIRED sAFErr GLAZING REQUIRED VA2,0 1/420 I/42.0 1/420 STAN/STAIN I/A2.0 STAIN/STAIN 1142.0 STAN/STAN sAFErr GLAZING REQUIRED I/A2;0:' 4 ST-AIN/STAIN SKYLIGHT XA22 .20/42' TYPICAL WINDOW SCHEDULE NOTES 1. NOTE WHERE. SAFETY GLAZING 1$.,1NI:),I-CATED, BUT NOT SCHEDULED IN. SEC.TION.oa 80::00., ALL UNLAMINATED. GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED :0LAZING. PANELS NEED. NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IOENTIFICATION AS SAFETY !WEE? GLAZING PER CODE 2. FIELD VERIFY ALL .EXISTING WINDOW :OPENING. jatiMEN$1ON$ SHALL mikkF FINAL FINI41-71-§5LEO.TIONS FOR WINDOWS WOOD TRIM OpNTRAPTQ, SHALL :COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 4. FOR HEAD FLASHING INSTALLATION REFER 'TO HEAD FLASHING DETAIL 'A' ON WINDOW TYPES, .SCHEDULE & DETAILS SHEET. 1" min. Ilis4;" HEMMED EDGE SLOPE 1 END cL05URE HEAD FLASHING DETAIL TYP. 3" = 1 - 0" cAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL .SELF4DHERING MEMBRANE PENETRATION FLASI-ING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLAwNa. Typ AT HEAD AND JAMS* REMOVE (E).T-11.1 SIDING FOR INSTALLATION OF NEW IUJNPQW ASSEMBLY AND TIR111. REPLACE OR RE. NSTALL SIPNG AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED siDING To MATCH (E).SipiNG. PRE-PRIMEP, GALV 51-IEET METAL FLASHING w/ END CLOSURE UNDER SELF•API-ERNG MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO SE FIELD DE1ERINED BACKER W)12 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY REMOVE. (E) T-111 SIDING FOR INSTALLATION PV NEW. WINDOW TRIMS. AND REATTACHMENT OF (E)SDING TO WINDOW OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL. WINDOW NAILING FLANGE OVER .SELF ADHERING MEMBRANE FENETRATION FLASHI114 INSTALL SECOND LAYER OF SELf ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMEt4T. CAULK NEW VERTICAL SIDING JOINTS SET NAL 14EADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) T -III SIDING (E) WALL. UNDERLAYMENT (E) EXTERIOR SWEATI-ING TRIm- MATCH (E) TRIM. PRIME ALL SIDES AND PANT TO MATC14 (E) TRIM. COLOR TO BE FIELD DETER BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ) 311 \ WINDOW HEAD •-(E)-0445 (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE TOUCI4 UP PANT, AS REQ'D coNTINUoUS SEALANT, TYP. SOLID W00D TRIM WD. JAMB I-INING. FINISH TO NtAICII (E) SEALANT 4 BACKER ROD •SHIM AS NECESSARY FILL GAP CU/ BATT INSULATION ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT Mail NAIL FLANGE TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PANT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINE', REMOVE (E) T -III SIDING FOR •INSTALLATION OF NEW WINDOW AssgnsLy .ANPTRIM. REPLACE OR RE NSTALL SIDING AS REQD.'PANT MODIFIED StIN TatiATO4:fE) SIDNG (E) EXTERIOR SHEATHING WINDOW JAMB WINDOW SILL T-111 SIDING -WIN 3" = - 011 DOW DETA (E) GLOB TOUCH UP PAINT, AS REQD CONTINUOUS. SEALANT, TYP. SOLID WOOD TRIM • SWIM AS NECESSARY FILL GAP W/ BATT • INSULATION E3AcKER ROD 4 SEALANT 314" Loop. SILL SOLID woo• TRIM. L SET CONTINUOUS SEALANT, Tr°. TOUCH UP PANT, AS REQD SELF -ADHERING MEMBRANE (E) GIS CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF-ADWERNG MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASWING. TYP AT HEAD AND JAMES& REMOVE (E) T -11I SIDING FOR INSTALLATION OF NEW LUNDOLU ASSEMBLY AND TRIM. REPLACE OR RE NSTALL SIPNG AS RECD. MAINTAIN (E) COURSNG. PAINT MODIFIED SIDING TO MATC14 (E) FRE -PRIMED, GALV SHEET METAL F1-4514NG WEND CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO EE SELECTED IN THE FELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PANT TO MATCI4 (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY REMOVE (E) T-111 SONG FOR INSTALLATION OF NEW LUNDOW TRIMS AND REATTACHMENT (E) SIDING To WINDOW OPENING:FRAMs*. LIFT (E) WALL UNDERLAYMENT AND INSTALL. WINDOW / NAILING FLANGE :OVER SELF ADHERING -MEMBRANE 'PENETRATION' FLASWING. 'INSTALL SECOND LAYER .OF SEL r ADHERING MEMBRANE OVER NAILING FLANGE AND- LAP UNDER.:(E) UNDERLAr‘ot CALK NEW vERTICAL SIDING )0INT8 4 SET -NAIL HEADS:FLAK PAINT MODHEO, TqMATPH •(E)SIDING (E) T111 (E) WALL WALL UNDERLAYMENT (E) EXTERIOR SHEATHING TRIM- MATCI4 (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD SEALANT - ACOUSTICAL WINDOW ASSEMBLY (E) GU (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE TOUCI4 up PAINT, AS IRE= CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WD. JAMB LINING. FINISH TO. MATCH (E) SEALANT 4 BACKER ROD SHIM AS NECESSARY FILL GAP UP BATT INSULATION WINDOW HEAD Au 2 ' 1-----: 1 41: 1111101 s,.. ...„, ...z. 1 1 111 1=1 ACOUSTICAL WINDOW ASSEM81-Y BACKER ROD 4 SEALANT - WNDOW NAILING FIN TRIM- MATCH (E) TRIM. PRIME ALL saxes AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED REMOVE (E) T -11I SIDING FOR INSTALLATION OF NEW WNDOW ASSEMBLY AND TRIM. REF'LACE OR RE NSTALL SIDING AS RECVD. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) EXTERIOR SHEATHING WINDOW JAMB 411 WINDOW SILL T-111 SIDING - WINDOW D 3" = 11 - (E)U.B. TOUCH UP PAINT, AS REQD CONTINUOUS SEALANT, Try,. SOLID 1.1100P TRIM • SHIM AS NECESSARY FILL. GAP W/ BATT INSULATION BACKER ROD .4 SEALANT 3/4" WOOD SILL 1/2" ROUND WOOD TRIM • CONTNUOUS 5A1 -ANT, TYP. (E) LIJP, JAMB LINING SELF-AD14ERNG MEMBRANE (E) TWIN SET BRICK *VENEER (E)GWE5 ETAIL SET REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 1 2013 City of Tukwila BUILDING DIVISION RECEIVED OfTV OF TuKwitA JAN 07 2013 S.M.STEMPER ARCHITECTS A Profeaaional Limited Liability. Company 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 90106 (206) 624-2777 • FAX (206) 624-2973 •-• 0810.03.2228 JUNE 7, 2012 0 ID —J 0 rt UJ KING COUNTY IMPROVEMENTS AI P NUMBER 3-53.0058-044 0 0 DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT J 0 PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03,2228 DOOR TYPES 1 a A FLUSH SCW o/ cTANGLE LITE' 4 PANELS W/ PATTER4ED SAFETY GLAZING LW OBSERVATION PORT SECONDARY SLING GLASS ppoR, V)/ isAFETy GLAZING EXTERIOR SJNGLEI LEAF STORti WI SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE VV x H FINISH INT./ EXT. HARDWARE. SET/FINISH KNOB / LEVER. SET LOCK SET DETAIL SET LIVING ROOM A 3l -II x V -s!'• ST.AIN/ -STAIN • PK -4 LOCK -1 Vat BREAKFAST A 3cv"- STAIN/STAIN, DK -2 LQCKI -1/A2J 3. 4 D INING.,Room L IVING;ROoM A STAIN/ STAIN NW -I / 50$ PK -4 LOCK -i 1/A2.1 5q1:ti 2/A2.I 5 LIVING ROM C I' -V' Vat BREAKFAST C DN NOROOM C 3'-;r xJIJ 1/A2.1: TYPICAL DOOR SCHEDULE NOTES 1.: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED. N SECTION oe KM, ALL UNLAMINATED GLAZING PANELS INTHAT UNIT ARE TO. BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION: AS SAFETY RATED GLAZINPER CQDE. 2. :SLIDING:= GLASS DOORS SHALL 'MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR 00vsp. 3. FIELD VERIFY ALL EXISTING DOOR OPEN NG pitvisNSIONsi. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR. DOORS AND INTERIOR! EXTERIOR WOOD TRIM.. QQNTRAQTOP SHALL COORDINATE= WITH HOMEOWNER PRIOR TOSTARTOF WORK. 5. FOR HEAD FLASHING INSTALLATION „REFER TO HEAD FLASHING DETAIL /V' ON DOOR TYPES, SCHEDULES .& DETAILS SHEET. V ran. 1451141ED EDGE SLOPE LEND CLOSURE HEAD FLASHING DETAIL TYP. 3" = 1' - 0" REMOVE (E.) T111 SIDING FOR. INSTALLATION OF NEW DOOR ASSEMBLY AND .TRim.REpLAcE OR RE INSTALL SIDING AS REQ:). MAINTAIN (E) .coURSNG. FAINT MODIFIED SIDING TO MATCH. (E) SIDING. (E) EXTERIOR SWEATI4ING SELF ADHERING MEMBRANE ToUci-I UP PAINT,. AS REQ'P CONTINUOUS CAREFULLY LIFT (E) WALL uNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAyMENT OVER PENETRATION FLASHING. TW Al' HEAD AND JAMBS. PRE-FRitiED, GAO( WET METAL •pi_AsHiN4 Bap CLOSURE UNDER SELF-ADHERNG MEmBRANE. COLOR To BE sELECTED IN NE FIELD CONTINUOUS SEALANT BEHIND Z BAR Pgat STORM DOO R PER SCHEDULE SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR: WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE IR.SMOVE (E) T-111 SIDING FoR INsTALLATioN OF NEW POOR TRIMS AND REATTACHMENT OF 'EV SIDING. TO DOOR OPENING FRAMING. LIFT (E) WALL UNPERLAYMENT AND INSTALL SELF ADHERING MEMBRANE IFENETRATO• FLASHING : INSTALL SECOND LAYER OF SEL ADHERING MEMBRANE AND LAP UNDER (E) 441- UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS 'FLUSH. PAINT MODIFIED SIDING TO .MATC14(E).SIDNG (E) T -w SIDING CONTINUOUS SEALANT 15E14IND Z DAR Plume stow. DOOR PER SCI4EDULE DOO R HEAD. CE) EXTERIOR SHEATHING KEW AS REQUIRED FOR WEATI-IER STRIPPING. INSTALLATION CONTINUOUS WEATHER-STRIPPING JAMS BEYOND WOOD DOOR PER SCHEDULE POOR SHOE 2" MN. 2" MIN. DOOR JAM DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE • B DOOR S ILL T-111 SIDING - DOOR DETAI 3 = i - 0" EXISTING FRAMING TOUCH UP PAINT, AS REQD CONTINUOUS SEALANT, Ti -P. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP 0.1/ BATT INSULATION POOR PER SCHEDULE L SET CE) EXTERIOR SHEATHING CONTINUOUS SEALANT 2X. TAPERED CAP PAINT To.rwcH (E) TRIM CONTINUU5 2x SOLID BLOCKING AROUND PERIMETER OF iPOOR FRAME: PAINT ALL EXPOSED EDGES TO MATCH tE) TRIM SECONDARY SLIDING STORM POOR ASSEMBLY. NSTALL PER MFG'R .INSTRUCTICNS CONTINUOUS SEALANT TRIM- PAINT TO MATCH (E) TRIM CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME. PANT ALL EXPOSED EDGES TO MATCH (E) TRIM SECONDARY SLIDING STOW DOOR. AssEMBLy. INSTALL PER MFG'R INSTRUCTIONS WO. TRIM BEYOND SOLID WOOD LINING DOOR HEAD If I.;.).... SECONDARY SLIDING STOW DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS. (E) FINISH FLOOR DOOR JAMB 501.I.p WOOD LINING (E) SLIDING GLASS DOOR CE) SLIDING GLASS DOOR CE) coNC, SLAB. OR (E) UP. FLOOR FRAMING DOOR SILL INTERIOR SLIDING GLASS DOOR DETAIL SET 3" = 1 - 01! REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 1 2013 City of Tukwila BUILDING DIVISION RECEIVED MY OF TUKWIIA 'JAN.07 20131 4EFItitilT CENTER ei4 S.IVISTEMPER ARCHITECTS A Professional Limited Liability. Company 4000 DELRID GE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 0810.03.2228 JUNE 7, 2012 1 -- Ce 0 cLLil z z 0 0 0 z MPROVEMENTS AI P NUMBER 3-53-0058-044 0 z DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03,2228 EXISTING ROOF (E) ROOF FRAMING (E) EAVE VENT BLOWN IN CELLULOSE INSULATION WITH A COMBINED VALUE OF NOT LESS THAN R-36 INSULATION DAM DETA IL INSULATION (E) WALL FRAMING EXISTING VENT COVER EXISTING RC:"OF VENT EXISTING ROOF STRUCTURE CROSS SECTION EXISTING ROOF STRICTURE NEW 2") SPACER 40 REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2"X SPACER LATERAL SECTION ROOF VENT EIA.FFL 1 1/2" = 1' - 0" 6" MIN. TYPICAL TOP 4 BOTTOM NEW 1" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. E DETAIL 2X WO LEDGER TYR SEALANT, ALL SIDES EXIST. SKYLIGHT CONSTRUCTION 2X LID FRAME LW REINFORCED CORNERS 1/4" TEMPERED GLASS EXIST. WALL CONSTR. SECONDARY SKYLIG - Ol WOOP STOP, TYP. CASEMENT LATCH HT DETAI L EXIST. CEILING (2) SIMPSON A-34 • EACH SIDE PANEL EXIST. GABLE VENT NEW ill GALV. HARDWARE CLOTH OPEN TOP in COX PLYWOOD AT (3) SIDES 1" OWENS CORNING .103 INSULATION, TYPICAL SECURE t1)1114 PIN TYPE FASTENERS TO PLYWOOD BACK AND SIPE PANEL NOTE: 1. AFTER FABRICATION, BAFFLE SHALL SE SECURELY ATTACHED IN POSITIM 2. NEW 13,4FPLE SHALL BE AT LEAST AS WIDE AS THE EXISTING VENT OPENING. GABLE END VENT BAFFLE DETAIL 1 1/2" - 0" CEILING BEST HERE 4" MN ACCEPTABLE HERE NOTE; REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. SIDE IW4LL SMOKE DETECTOR INSTALLATION DETAIL = 1' - On REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 1 2013 City of Tukwila BUILDING DIVISION Immo CTIIV Tt # 'JAN 07 2013 S.MSTEMPER ARCHITECTS A Frofeasional Limited Liability Company 4000 DELIRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) -624-2777 • FAX (206) 624-2973 • . , 'STATE,: 0810.03.2228 JUNE 7, 2012 0 0— rt —J 0 F - WI Fz 0 C0 MPROVEMENTS Ui Ui Ui z LL 0 47Z Ui cn AIP NUMBER 3-53.0058.044 0 F— DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT J PROJECT MANAGER ML&TF DRAWN LB&CP MISC. DETAILS A2.2 0810.03.2228 LIFT (E) ixpa PAPER AWAY LOOSELY FROM CE) SHEATHING AT JAMES AND HEAD 4. • NOTE: REMOVE (E)sjpiNG IEACK FROM (E) RA •AS REQ2 CE) 511:>N0 NOT •Watk.FOR. cLARITT. !‘tEtz,,,APE AND OR INSTALL NEW SIDING AFTER rigrig3RANE FLASHING. WAS IGEN INSTALLED. 12" COR4ERS, TYP. LAP SILL MEMBRANE FLASHING 2-1/2" OVER CE) BLDG. PAPER AT SILL. EXTEND I i" BEYOND RO. AT EA END OF SILL. CE) BLDG. PAPER AT SILL •(E) SHEATHING CUT SILL FLASHING 4, FOLD THROUGH RO. AS SHOWN, ADHERE MEMI5RANE FLASHING TO OUTSIDE FACE OF WALL SHEAT 4" MIN 4" Trp. )MEMBRANE FLASHING AT SIL SCALE: NTS. LIFT (E) SLPG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. \\.•... rr (E) SIDING NOT SHOtIN FOR CLARITY. L BUTTERFLY CORNER FLASHING WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SI-lcuLD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL. 4 NOTE: REMOVE (E) SIDING BACK FROM CE) •R.O. AS :RE'P (E) SIDING NOT SWIM FOR CLARITY. REPLACE AND OR INSTALL NEW SUNG AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. MEMWNE: FLASHING PREVIOUSLY APPLIED TO WINDO(L: CrENIt** ELEVATION VIEW NOTE: INSTALL WINDOW. PER MFGRS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE NSTALLATION SEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. CE) SHEATHING REMOVED SCALE: NTS. EDGE OF (E) SIDING, SHOW DIAGRAMATICALLY, CE) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK paw OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE: is) SIDING BACK FROM CE)w.. AS REQ'P (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING WAS SEEN INSTALLED. -- WHERE: REF TRIM (E) BLDG PAPER AT HEAD TO PREPARE FOR INSTALLATION OF HEAD F ASI4ING AND WINDOW TRIM (FOLLOWING STEPS). HEAD FLAS SCALE: NTS HI N. PREPARATIO (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. CUT JAMB FLAS1-11% FOLD AROUND WINDOW OPENING AS SHOLIN. EXTEND I-1/2" BEYOND Eva OF OPEN MG AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING. TO OUTSIDE FACE OF WALL si-gATI4ING. MEMBRANE FLASHING AT JAMB SCALE: NTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS REGI'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ••,• N N, s., \ ‘ I .4:.... 4e A k \ s ‘ *W"ii__O fel ..e2,0`4•4:"' /' • / ..,:". ..... .:::.(.*:IP..... .....:, .1../.../...:X.:* Y.' •:.+//". 7.; 0'4 f.... .:. 7 <.//c4". . . ,.. „, ..• / ,..e.,../..„., 0..? .,..to:4•., ......• 0' • ,,,-- , . .. 4.. 1 ,4,754 1,4% • „...‘:.„ .0.....) — hid.? Ai I i Atsrte•I A.i AI Joao- ors AliZt I ink 11l I I NAILING FLANGE AND FLASHING. INSTALL SHT.rETAL .I -EAE: FLASHING UNDER (E) BLDG PAPER TRIMMED EDGE OF (El:SIDING, 51401114 DIAGRAM. ATICALLY, CE) SIDING NOT 54 fOR CLARITY, MEMBRANE. F. SCALE: NTS ING AT JAMB NQTE; REMOVE.: fWElpINOl5AcK FROM (E)R. AO 'RE:OP mYsipiwNDT:E4490,1: FOR cLARITT, REPLACE AND OR INSTALL WEU) SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. • ALLOW VS" :m7/47M77.4r-4""-- Mr-x/. • BETWEEN E 0. SOT. CLEARANCE AE141NO. AND EDGE . OF (E) SIDING. HEAD. FLASHING INS- SCALE.: NTS ALLATION CE) BLDG. PAPER CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND I-1/2" BEYOND RD. AT 1-1EAD AND JA11136. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (Trio. EACH SIDE (7 WALL) MEMBRANE FLASHING AT HEAD SCALE NTS NOTE: REMOVE CE) SIDING BACK FROM (E) RO. AS RED (E) SIDING NOT SHOWN FOR CLARITY. REPLACE MD OR INSTALL NEW SIDING AFTER MEMBRANE. FLASHING HAS BEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. • L ..W440".• 4,7 e. e /730:Mg,:://, 444 0 • I J WINDOW 'FLASHING SCALE: NTS NSTALLATION GENERAL NOTES: maieRANE FLASHING IS SPECIFIED N 01 62 00 AS "SELF ADHEARNG MEMBRANE FLASHING" TYPICALLY 1. REP TO AS FEL AND STICK" 2: PETALS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5 AND 611 REFER TO MEMBRANE INSTALLATION AFTER.WINDOW WAS SEEN SET IN PLACE, SHIMMED, AND ANCHORED.. DETAILS "1 AND V` REFER TO SHEET METAL HEAD FLASHING. 5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK JOINTS. SHEET METAL HEAD FLASHING CE) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL WP. TRIM. BUTT TIGHT TO immtleD EDGE OF (E) SioiNG. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. 0 WOOD TRIM INSTALLATION SCALE NTS LEAVE I/4" -3/S" GAP BETWEEN. WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 1 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUICWIIA JAN ,0 7 2013 PERMIT CENTER s.msT.EmpER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 20.0 • SEATTLE, WA 98106 (206) 4324-2777 • FAX (206) 624-2973 0810.03.2228 .T:f..:W.PW • JUNE 7, 2012 Ce 0 cL0 w F- 0 0 AIP NUMBER MPROVEMENTS 3-53,-0058.044 0 0 DATE JUNE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCH JO TECT PROJECT MANAGER MI-8tTF DRAWN LB&CP WINDOW FLASHING DETAILS A2.3 0810.03.2228 •ABBR EVIAT1ON$ LEGEND DRAWING INDEX ACM ACU AFC AFF APPROx ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC, COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN M TG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC $G SHT SM SMC SO SP SPD SPEC SRC TDI -1 TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED: CEILING ABOVE FINISHED, FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR:!, CONDITIONING BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN. FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND. DIFFUSERS, GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR HOT WATER HOT WATER :CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY' INCH KILOWATT, Clow WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE, LEAVING WATER TEMPERATURE. MAXIMUM 1000 BTU PER HOUR: MINIMUM CIRCUIT AMPS MINIMUM MOUNTING, MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION:. NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER, OPPOSED BLADE DAMPER,: PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN. GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP - SPECIFICATIONS :SEATTLE :RESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP OF. DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT; VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE. WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE ENGINEERS CONDITIONING ASSOCIATION NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS U STEP SYMBOL ABIE. OR XX 0 X/Y S. DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIR EcTioN OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL. DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE MLO LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX MECHANICAL FLOOR PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL sysTEm. SHALL CONSIST or ALL WORK SHOWN ON THE ORAWINQS, INCLUDING FLOOR PLANSDIAGRAms, DETAILS. ETC.. AND ALL WORK : As IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM-, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE ,MECHANICAL SYSTEMS AS SHOWN AND: SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL. SYSTEM ;:COMPLETE WITR. ALL MECHANICAL WORK AS REQUIRED, FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED' BY THE MANUFACTURERS:1.1.STED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS: ALL SCHEDULED AND. SPECIFIED CRITERIA. AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL :REPRESENTATIVE. :COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN 'WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT •SUBSTITUTIQR„ 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING:. EQUIPMENT, DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK : iPENETRATIONS THROUGH 'WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS -SHALL. BE SEALED AIRTIGH AIRTIGHT. T DUCTWORK, OR STRUCTURAL COLUMN S. PROVIDE ALL REQUIRED. ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS 7: PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL. MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESEN THERMOSTATS 41-0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.. 10. MAINTAIN 101-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 31-0' CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. PENETRATION THROUGH WITH DUCTS SHALL BE SEALED THE ELECTRICAL CONTRACTOR. TATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE NCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, SYMBOL ABBR SG -X, XXX -ol- DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD RA/EA RG SA SA RA/EA SD VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN. AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR. DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH E Z,fR (p THERMOSTAT QUIP ID# • LOCATION 3 0 I•I MOD INC MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUI REMENT MECHANICAL/ELECTRICAL COORDINATION ITEM NO. EQLI1PMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURN SHED UNDER DIVISION INSTALLED UNDER DIVISION 23 26 23 26 N/A WIRED UNDER poi ISIQN 23 26 N/A REMARKS MOTOR OPERATED. DAMPER THERMOSTAT 24 x x 24 x xl X 1,2 REMARKS:: -VERIFY: QUANTITY FROM PLANS (TYP CAL ALL). DISCONNECT SWITCH WAC RESIDENCE CODE FLOOR AREA pa FT..). NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2228 2191 2 120 CFM ,C:F I. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE ICODE (WAC), SECTION 51-51-1508, TABLES MI508.2 AND M1508,3 THERMOSTAT/SWITCH HOURS OF OPERATION SET THERMOSTAT/SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION. CALCL.LATION PER WAC 51-51 M1508. 3: QF = QR / (&EGR X F) QR = (FROM TABLE M1508.2) EQ. &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 60 / (1 X 1/2) = 120 CFM SEPA PERMITKID APPROVAL REQUIRED RECEIVED CITY OF r MVO a I JAN 07 2013 PERMIT CENI EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A 1Potetosia1 ilialted UAW, Cosaway 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 96106 BOB) 624-2777 FLY (BO) (124-247a THE GREENBUSCH GROUP, INC ********* ))) ACOUSIICALliciAtiriso‘syla tallECHANICAL ENCINEERINO Mer178-0569 (200 3711-0841 FAX SIPMIE. UM 0810.032228 NTERNATIONAL AIRPORT 0 0 ATP NUMBER 3-53-0058-044 DATE 06/05/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, ex, DWG INDEX M 0810.03.2228 FH (E SG DINING ROOM KI TCHEN f3ATH (E) DUCT UP T ROOF CAP !BREAKFAST ROOM STU Y OTELIT MAIN FLOOR MECHAN CAL PLAN SCALE: 1 /4" = 1 '-0" z Ct. LJ FURNACE CEILING (E) OUTSIDE AIR DUCT CONNECTION FURNACE ELEVATION SCALE: NONE FLOOR LIVING ROOM (E)SG NICI)1111)RTH (E) ROOF CAP UPPER FLOOR MECHANICAL PLAN SCALE: 1/4!" 1 '-0" CLOSET' ON !BEDROOM NQTE$lt,. 1. RESIDENCE IS. FULLY CONDITIONED By A DUCTED FURNACE SYSTEM. RESIDENCE ALREADY HAS OUTSIDE AIR DUCT, MOD AND TIMER SWITCH INSTALLED. 2, FIELD VERIFY .otrisiDE. AIR INLET .,LOCATION IS AT MINIMUM 10. FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC SEC11OR MI508044, 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER. 51-51,SECTION M1508:5:2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS. SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE: 4. FILTERS: AFTER EQUIPMENT AND. SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB. WORK, PERFORM THE FOLLOW:IND: A) REPLACE AIR FILTERS IN: THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. FLAG NOTES: REMOVE THE EXISTING THERMOSTAT AND PROVIDE WSEC 1.1112.4„,,,METTIED LA COMPLIANT THERMOSTAT AS SPECIFIED: AFFIX A LABEL TO THE ”" CONTROLLER THAT READS 'WHOLE. HOUSE VENTILATION (SEE JAN �7 2013i OPERATING INSTRUCTIONS)" PER WAC 5151, SECTION 10508.5,2. PERMIT CENTER CONTRACTOR TO PROVIDE TESTING AND BALANCING OF EXISTING FURNACE AND DUCTWORK. sEPARAre PERAtliTAND APPRovAL 'VW/RED EXPIRES: 9/08/2012 Pool. Waited 118102.10 *allow .4000 DELRIDGE WAY SW STATE 200 SEATTLE, WA 08106 (208) 824-2717 ^ .PAZ (208) 824-41278 THE. GREENBUSCH GROUP, INC 410.411104041*) PCOUS11CAL, AUDIO JV112E0IA SWIMS./ 0.21NEERINO 1000 War ,N SMELT ME 201 Min& IN 1211111 (200 378-0502 (200) 376-0041 FAX 0810.032228 0 z 0 ce 0 0 0 cf 0 0 ct 0 c7) AIP NUMBER 3-3-00513-044 DATE 06/06/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL FLOOR PLANS AND DETAILS M2.0 0810.03.2228 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLMON OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK; TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDIT1ON. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN N OTES PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. / .1 t?ININ.n 5•RFAX:F45T FQOat-I NORTH QQM •I 2 L x J. ELECTfRICAL LEGEND mem 0 DESCRIPTION liGHTING OR POWER PANEL BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2*C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP CND. INDICATES ISOLATED GROUND. MAST, WEATHERHEAD menmessairlIpm— Eal BRANCH CIRCUIT HOME RUN DESCRIPTION EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. DAMPER CONNECTION NON-FUSED DISCONNECT SIMTCH TOGGLE TYPE MOTOR DISCONNECT SWITCH WIN THERMAL OVERLOADS SMOKE DETECTOR ELECTRICAL METER TIMER OPERATED MICH - — AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT 0 THERMOSTAT UNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR 1 T F3FDROCP1 c.L,05,ET 5EID:ROOM A714 t L, SEOM ••) 010 SEPARATE PERMIT APPROVAL' REQUIRED RECEIVED err., OF TUKWILA JAN 07 2013 WIM1T CENTV, se.mETEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 290 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 0810.03.2228 NTERNATIONAL AIRPORT z MPROVEMENTS >- w w ce w 0 zLL AIP NUMBER 5-53-0058-044 SEATTLE WASHINGTON DATE JUNE 7; 2012 ISSUED 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810 03.2228