Loading...
HomeMy WebLinkAboutPermit D13-013 - RIVERA RESIDENCE - REMODELRIVERA RESIDENCE 11826 44 PL S D13-013 Parcel No.: Address: Suite No: Project Name: City 411P Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov 3347400745 11826 44 PL S TIIKW RIVERA RESIDENCE DEVELOPMENT PERMIT Permit Number: Issue Date: Permit Expires On: D13-013 01/15/2013 07/14/2013 Owner: Name: Address: RIVERA REYNALDO B+MYRNA V+J 11826 44TH PLS , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: G & G SPECIALTY CONTRCTORS INC Address: 4633 S 36 ST , PHOENIX AZ 85040 Contractor License No: GGSPEGS919RT Lender: Name: Address: Phone: 206 296-7437 Phone: 480-921-4079 Expiration Date: 12/31/2013 DESCRIPTION OF WORK: RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE - WORK TO POTENTIALLY INCLUDE SELECTIVE REPLACEMENT OF WINDOWS, SELECTIVE REPLACEMENT OF INTERIOR/EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS, INSTALLATION OF SECONDARY SLIDING GLASS DOORS AND SKYLIGHTS, ETC. Value of Construction: $29,761.00 Type of Fire Protection: Type of Construction: VB Electrical Service Provided by: SEATTLE CITY LIGHT Fees Collected: International Building Code Edition: Occupancy per IBC: $1,092.10 2009 0022 **continued on next page** doc: IBC -7/10 D13-013 Printed: 01-15-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied N N N Number: 0 Start Time: Volumes: Cut 0 c.y. Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Public: Non -Profit: N Public: ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not pres construction o g4 erforman e of duork. to this permit Signature: Print Name: e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit and agree to the conditions attached 6 Leatui Date: /-/c-/3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All wood to remain in placed concrete shall be treated wood. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary doc: IBC -7/10 D13-013 Printed: 01-15-2013 sewer connections, and properly fill or othlit e protect all basements, cellars, septic taziells, and other excavations. Final inspection approval will etermined by the building inspector based atisfactory completion of this requirement. 8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D13-013 Printed: 01-15-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.d.tukwila.wa.us Building Permit No. _ Mechanical Permit No. r5.:- Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 11826 44th PI. S. Tenant Name: Myma and Reynaldo Rivera Property Owners Name: Myma and Reynaldo Rivera Mailing Address: 11826 44th PI. S. King Co Assessor's Tax No.: 3347400745 Suite Number: Floor: New Tenant: 0 Yes ® ..No Tukwila WA 98178 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296-7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker@kingcounty.gov City State Fax Number: (206) 269-7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody@smstemper.com or tim@smstemper.com City State Day Telephone: (206) 624-2777 Fax Number: (206) 624-2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H:\Apphcations\Fonns-Applications On Line\2009 Applications\l-2009 - Permit Application.doc Revised: 1-2009 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ N2376 "1\(1J t Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? 0 Yes 0.. No If yes; a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If `yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm I None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2 " x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Apphcanons\Forns-Applications On Line\2009 Applications\I-2009 - Permit Applicanon.doc Revised: 1-2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lst Floor 1,419 2nd Floor 744 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If `yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm I None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2 " x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Apphcanons\Forns-Applications On Line\2009 Applications\I-2009 - Permit Applicanon.doc Revised: 1-2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND.I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER NT Signature: Date: \/7/13 Print Name: Timo y J. Fenlason, SM Stemper Architects, PLLCDay Telephone: (206) 624-2777 Seattle Mailing Address: 4000 Delridge Way SW, Suite 200 WA 98106 City State Zip Date Application Accepted:tA Date Application Expires: Staff Initials: 1 01 \ A H: Applications\Forms-Appltcanons On Line \2009 Applications\I-2009 - Permit Application:doc Revised: 1-2009 bit Page 6 of 6 I PLUMBING AND GAS PIPING PERMIT INFORMATION - 206-431-3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provid- detailed information): Building Use (per Int'l Building Co. Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewe Indicate type of plumbing fixtures and/or gas p •ng outlets being installed • d the, quantity below: Fixture Type: Qty Fixture Type: Qty Fixt e Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Cl, es washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) ood-waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or -nt ndustrial waste treatment erceptor, including trap an vent, except for kitchen typ • . rease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen (>750 gallon capacity) Repair or . eration of water pi, g and/or water treat t equipment Rept • r alteration of drainag• •r vent piping Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 : kflow protective . evice other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow pre •ctive device other than atm • •heric-type vacuum breakers ver 2 inch (51 mm) dia er Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backfl• protections (1-5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:\Applications\Forms-Applications On-Line\2009 Applications\I-2009 Permit Application.doc Revised: 1-2009 bh Page 5 of 6 City o'ukwilar Department of Community Development 6300 Southcerter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: hitp:I4vww.ci.rulnvila.wa.us SET RECEIPT • RECEIPT NO: R13-00124 Initials: JEM Payment Date: 01/09/2013 User ID: 1165 Total Payment: 13,045.45 Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE) SET ID: S000001897 SET NAME: KING COUNTY NOISE ABATEMENT SET TRANSACTIONS: Set Member Amount D13-004 D13-005 D13-006 D13-007 D13-008 D13-009 D13-010 D13-011 D13-012 D13-013 M13-003 M13-004 M13-005 M13-006 M13-007 M13-008 M13-009 M13-010 M13-011 M13-012 TOTAL: 1,018.34 1,239.61 1,313.36 779.67 1,116.68 1,141.27 1,313.36 1,092.10 1,239.61 1,092.10 167.70 186.50 177.10 167.70 177.10 177.10 124.25 177.10 167.70 177.10 .1, 01'8 .34— _ I,, ONS 14( TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 13,045.45 TOTAL: 13,045.45 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES 000.322.100 6,849.15 City ukwilar Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: him:/Svww.ci.tukwila.wa.us STATE BUILDING SURCHARGE 640.237.114 45.00 TOTAL: 13,045.45 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 lz (206) 431-3670 Permit Inspection Request Line (206) 431-2451 3(3-01_3 l�.e (J -PJ" A. �. Type olnspectio : � t.--'1 tr.)QJ 11.13('A4Proj�6 Addres l: �2 44 —i8 E... � Date C�ICIed: 1 Special Instructions: ► Date Wanted. ,.Li a. k Requester: Phone No: -4°— S'I J,j — (0- Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: t,v ),-nt e. (e' p-1°iR l t /—r,/1 ) .--'"'N N p 4 Inspector: Dater REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Jennifer Marshall From: Sent: To: Cc: Subject: Tim Fenlason <tfenlason@jonespayne.com> Tuesday, January 08, 2013 11:29 AM Jennifer Marshall sharyn.parker@kingcounty.gov; Jesse Holgate Re: KCIA RANRIP Submittal You are correct. I'd like you to change the applications to reflect the amounts in the pink column. I thank you for this extra work and if you'd like, I can gladly drive to your office to make the changes. On Tue, Jan 8, 2013 at 9:56 AM, Jennifer Marshall <Jennifer.Marshall@tukwilawa.gov> wrote: Good morning Tim, Due to the fact that I cannot just arbitrarily change information on permit applications, I am clarifying the direction you are giving me. Are you directing me to update the valuations provided on the applications submitted yesterday to the numbers below under the column highlighted pink and labeled "Value Originally Provided?" Applicant Name Ochoa Residence Nguyen Residence Aragon Residence Aragon Residence Carter Residence Christensen Residence Fasano Residence Kerr Residence Nguyen/Diem Residence Rivera Residence Address 11863 44 Av S 5016 Wallace St 4610 S 124 St 12245 46 Av S 1180240P1S 12212 48 Av S 12029 44 Av S 3834 S 116 St 11620 40 Av S 11826 44 P1 S Dev Permit Value Provided on No Application D13-004 $24,018.00 D13-005 $31,135.00 D13-006 $32,099.00 D13-007 $17,201.00 D13-008 $25,472.00 D13-009 $28,169.00 D13-010 $37,403.00 D13-011 $23,133.00 D13-012 $33,129.00 D13-013 $23,619.00 Value Originally Provided $26,622.00 $35,359.00 $38,407.00 $19,973.00 $30,978.00 $31,174.00 $38,918.00 $29,764.00 $35,722.00 $29,761.00 If these numbers are correct please respond accordingly and I place a copy of these emails in the file proving that I have been authorized to make the changes. If they are not correct, please provide me with the correction valuations. Thank you, Jennifer Marshall Permit Technician Original Message From: Tim Fenlason [mailto:tfenlason@jonespavne.com] Sent: Monday, January 07, 2013 4:18 PM 1 To: Jennifer Marshall • • Cc: sharyn.parker@kingcounty.gov; Bill Rambo; Jesse Holgate Subject: Re: KCIA RANRIP Submittal Jennifer, My preference would be to use the amount provided to Bill and to update the applications. I know that the amounts provided to Bill are correct, as I did those calculations myself. On Mon, Jan 7, 2013 at 4:08 PM, Jennifer Marshall <Jennifer.Marshall@tukwilawa.gov> wrote: > Good afternoon Tim, > I received the applications and plans for ten lots for the above > referenced project. I have completed the data entry in our permit > system and discovered there are discrepancies with valuations provided > to Bill Rambo and the valuations provided on the applications. I have > attached a spreadsheet showing those discrepancies. The issue with > there being a difference is that the permit estimate provided from > Bill is no longer applicable. > It is the end of my work day, so I will wrap this up tomorrow morning > (I probably will not be able to fit it in until about 10 am) and > provide the updated permit fees which will correspond with the new > valuations given. At that point we will need payment to be made > before the permits can begin the review process. I have also attached > the original worksheet you and Bill were working with for your reference. > Have a good evening. > Jennifer Marshall > Permit Technician, City of Tukwila > T: 206 431-3670, F: 206 431-3665 > jennifer.marshall@tukwilawa.gov Tim Fenlason Associate AIA Senior Job Captain 2 ,10 PERMIT COORD CAC PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-013 DATE: 01/07/12 PROJECT NAME: RIVERA RESIDENCE SITE ADDRESS: 11826 44 PL S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: A Awe_ P1-13 Building Division III Public Works Pf„AT 014►9'l� Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete p(J Incomplete ❑ Comments: DUE DATE: 01/10/13 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Notation: DUE DATE: 02/07/13 Approved with Conditions N- Not Approved (attach comments) ❑ REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Printer Friendly Page • w General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company G a G SPECIALTY CONTRCTORS INC 4809214079 4633 S 36Th Street Phoenix AZ 85040 Out Of State Corporation G a G SPECIALTY CONTRCTORS INC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602975812 Active GGSPEGS919RT Construction Contractor 12/31/2009 12/31/2013 General Unused Business Owner Information Name Role Effective Date Expiration Date GOODBALLET, CHARLES ELMER Chief Executive Officer 12/28/2009 Bond Amount WAVY, CHRISTINE Chief Operating Officer 12/28/2009 59BSBEA9058 GOODBALLET, JAMES SCOTT President 12/28/2009 GOODBALLET, TERESA LYNN Secretary 12/28/2009 INS CO OF THE WEST Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 HARTFORD FIRE INS CO 59BSBEA9058 12/18/2010 Until Cancelled $12,000.0001/03/2011 11/16/2012 1 INS CO OF THE WEST 2278440 12/18/2009 Until Cancelled $12,000.00 12/28/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 Companion Property a Cas Ins C PCP10000270101 11/03/2012 11/03/2013 $1,000,000.00 11/16/2012 3 National Union Fire Ins of PA PCP1000027 11/03/2011 11/03/2012 $1,000,000.00 12/27/2011 2 LEXINGTON INS 4392611702 12/31/2010 12/31/2011 $1,000,000.0001/11/2011 1 CO LEXINGTON INS 4392611701 12/31/2008 12/31/2010 $1,000,000.0001/14/2010 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 01/15/2013 KI NG COU ... ... .. . . . .. RAFT NOISE REMEDY IM PROV EMENTS :PROGRAM SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND SPECIFICATIONS INCLUDING BUT NOT LIMITED TO - APPLICABLE YES NO I. •SELECTIVE !REPLACEMENT OF EXISTING WINDOUJS WITH NEW VNYL-FIRAMED ACOUSTICAL WINDOWS. 2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. 3. INFILL OF EXISTING OF'ENINGS, 4, SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. 5. INSTALLATION OF STORM DOORS. 6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS. 1. INSTALLATION OF SECONDARY SKYLIGHTS. S. INSTALLATION OF PET DOORS. NSTALLATION CF FIREPLACE FRESH AIR VENt 10. INSTALLATION OF CHIMNEY CAP. 11. REGULATED MATERIALS ABATEMENT. 12.. ATTIC VENT 134,1+1:*5; 13. INSTALLATION OF ATTIC INSULATION. 4. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. 15. INSTALLATION OF MECHANICAL VENTILATION gouiptioit FURNACE MODIFICATION AND: ASSOCIATED: DUCTING. 16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. x 1. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. IS. INSTALLATION OF SMOKE DETECTORS. 13. NEU) ELECTRICAL PANEL / SERVICE. x 20. KNOB :AND, TUBE WIRING. x. SEPARATE PERMIT REQUIRED FOR: Mechanical electrical PoPiumbina rigraas City of Waft lk.DNG DNISION FILE CO 'Y Zi3:143 Permit No. PJ nrt nilaw approval Is subject to errors and omission& of construction documents does not auttritze .ion adopted code or ordinance. Rsce:pt y • -1 is acknowledged: 4.-.4Jprov By Date: City Of lbkwlla BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of TuktVila Building Division. Emtions will require a new plan submittal cr,.: may include additional plan review fees. C00747C12 Bi PACKAGE 3-53-0058-044 SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Seattle, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, International Mechanical Code 3341400145 ZONING: 5F1200 OCCUPANCY: (No Change) SINGLE FAMILY ',RESIDENCE CONSTRUCTION TYPE: (No Change V B NON. SPRINKLERED LEGAL DESCRIPTION: LOTS 4 45, BLOCK 4, C.D. HILLMAN'S MEADOW GARDENS ADDITION TO CITY OF SEATTLE, DIVISION *I, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 12 OF PLATS, PAGE(5) 64, IN KING COUNTY, WASHINGTON4 EXCEPT THE NORTHEASTERLY 62 FEET THEREOF. DRAWING INDEX T0,0 TITLE SHEET, PROJECT INFO, A1.0 FLOOR PLANS 4 NOTES 42.0 WINDOW TYPES, SCHEDULE 4 DETAILS A2.1 DOOR TYPES, SCHEDULE 4 DETAILS 42.2 MISCELLANEOUS DETAILS 42.3 WINDOW FLASHING DETAILS M1.0 LEGENDS, SCHEDULES, AeistRev., GENERAL NOTES 4 DWG INDEX M2.0 MECHANICAL PLANS AND DETAILS E1.0 ELECTRICAL FLOOR PLANS AND NOTES E1.1 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL.. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 351013 Ph: 206. 261 9233 Fax: 206. 256. 0I90 Contact: Sharyn Parker Sharyn.Parkerokinecounty.gov ARCHITECT: Sit Stamper Architects 4000 Delridge Way SW, Suite 200 Seattle, WA 35106 Ph: 206, 624, 2111 Fax: 206. 624. 2913 Contact: Jerry Osborn, Melody Leung, Tim Penlason, E-mail: jerryeamstemper.com melodyesmstemper.com timesmstemper.com ACOUSTICAL ENGINEER: SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 OSS, MS Fix: 206. S33. 0824 Contact: Mohamed Alt Allaoua" E-mail: mohamedeasaacoustics.coni MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph: 206. 315. 0569 Fax: 206. 315. 0641 Contact: Dylan Turner DylanTegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253. 412. 3463 Contact: Brent Rollins E-mail: 19cretremestcom REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle; WA 98102 Ph: 206. 232. 9639 Fax: 206. 162. 4150 Contact: Tim Ogden E-mail: tim_ogclen9pbaenvcom DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St 200 Boston, MA 02114 Contact: Tim Fe:Mason, Cynthia Maeda E -ma fl: CMascla ojonespayne.coin VICINITY MAP (NTS) STRUCTURAL ENGINEER:. Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA wiz Ph: 206. 622, 4500 Fax: 206, 622,-0422 Contact: Ron Martinson E-mail: ronmepsm-engineerke-041. REVIFWFfl CODE COMPLIANCE APPROVED JAN 11 'nil City of Tukwila BUILDING OlViSluil .oinrimmoiormosrpm.raimemoilaftwiDAMI. RECEIVED CITY OF TUI(WILA I JAN tO 7 2013 PERMIT CENTER ........................................ "1111''''fill!..!1111.111'11111.;1!JIII".11.;i11:11111111.111111111111.111:1''''''' '11i P1 P127 --CA NORTH S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, A 98100 (208) 624-2777 FAX (206) 624-2973 Aoci-irrEC:j • • r.: ............... • JUNE 7, 2012 MPROVEMENTS 02: AIP NUMBER 3-53-0058-044 PATE JUNE 7, 2012 ISSUED 100% CO PROJECT ARCHITECT J PROJECT MANAGER ML&TF DRAWN LB&CP PROJECT INFORMATION, DRAWING INDEX, DIRECTORY TO.0 0810.03.2231 LAUNDRY >4 SPECIAL NOTES: NOTES: I. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES, THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01 '11 01 AND 02 82.00:FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER t0 SECTION 01 11 01 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. KITCHEN. DINING ROOM BATH SELROO"I 2 G=ARAGE MAIN FLOOR PLAN LIVING ROOM PRIOR TO COMMENCING WITH DEMOLITION A "pre -demo inspection" is required. Contractors shall provide documentation that an "asbestos survey" has been completed. If needed, abatement procedures per "Puget Sound Clean Air Agency" shall be completed and documentation of compliance shall be provided at time of final inspection. GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS; WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETIIEEN 8•.00 All AND 5:00 PM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. T. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED: 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11 ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WI-1=R=SOPPITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING,DEMO (E) SHELVING AS REO'D AND RE -CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT, 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL SE CONCEALED. rt DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WO% REFER TO ELECTRICAL FOR TIMER LOCATION 18 INSTALL SMOKE DETECTORS, SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET EI.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. 19. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POUER OUTAGE IS BIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE .BEFORE 8:00 AM. 4 AFTER 5:00 pJ'L I............. CHIMNEY RAT'H '!" 'rssf'yn' v s}}fJ'}'afyj9ya.�s /ii/is'yrr.Nip A. EAST ..ELEVATION PLAN KEYNOTES I DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. C) DEMOLISH EXISTINGDOOR(S), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING,. TRIM, THRESHOLD AND STORM DOOR. REF. DOOR SCHEDULE. DEMOLISH EXISTING DOOR(S), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE. FLUSH SOLID CORE INTERIOR WOOD DOOR WITH TRIM Q PACKAGE BON ELEVATIONS, INCLUDE INTERIOR HARDWARE SET: '4 - COORDINATE WALL GRILL WITH MECHANICAL._ WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF: MECH. FOR INSTALLATION DETAIIL. 5 . BLENDING UNIT LOCATED ADJACENT TO (E) WATCH INSTALLED IN ATTIC, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT.. REF. 2/A22 FOR DETAIL b COORDINATE CEILING GRILL. WITH MECHANICAL DOCUMENTS. a DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A2.2 FOR DETAIL. COORDINATE WITH MECHANICAL DOCUMENTS. INSTALL PROGRAMMABLE TIMER SWITCH FORGONTROL OF BLENDING AIR UNI . COORDINATE. MECHANICAL AL AND ELECTRICAL DOCUMENTS. C) INSTALL NEW ELECTRICAL SERVICE AND NEW ELECTRICAL PANEL. COORDINATE WITH ELECTRICAL DOCUMENTS. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR ESLOCK ACCESS TO HOMEOWNER DRIVEWAY. AAP BEDROOM 3 r7 I I L _] 2 UPPER FLOOR PLAN 1/4" = 1.' B. SOUTH ELEVATION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 11 'nil AVA C. WEST ELEVATION LEGEND i\ ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE . LE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL. FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW C 1. 1111111111111 1:011 f •i L GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL. CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE. HOUSE VENT INSTALLATION. REF. MECH. 4 ELECT. RECEIVED REF. GENERAL NOTE 11 CITY OF Tt1KWILA IJAN .0 7 2013 PERMIT CEtuTEat ATTIC INSULATION ATTIC INSULATION DAM SD INSTALL BATTERY OPERATED SMOKE DETECTORS GAS INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER SOFFIT FOR MECHANICAL DUCTING S.M.STEMPER ARCHITECTS A Professional Limited Liability. Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, IYA 98106 (206) 624-2777 • FAX (206) 624-2973 R. 3S";• REI3 i III `( 033 F -Ef.3E 0810.03.2231 JUNE 7, 2012 F— Ce 0 E/��,�/ IL J z 0 z ct w F- z O U C9 z C/) E— z W 2 W 0 0 >0 w w w C/) 0 z F— u_ C ce f—' Ce AIP NUMBER 3-53-0058-044 0 F- 1 -- DATE H DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES A1 .0 0810.03.2231 WINDOW TYPES HORIZONTAL XX -SLIDER WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE I/V x TRIM FINISH INT./ EXT. REMARKS DETAIL SET B BEDROOM 1 41-10". x 4'4" STAIN/STAIN SAFETY GLAZNG REouIRED I/A2.0 BEDROOM 7-5" STAN/STAIN C I5EPRooM 2 DINING RooM x STAN/STAIN 1/A2� STAIN/STAIN E G KITCHEN LIVING ROOM 11:4" 61-0" x 4'-2" STAIN/STAIN 1/.42.0' 2/A2.(?) STAINASTAIN LIVING ROOM 4"4!" STAIN/VAN H LIVING ROOM BEDROOM A- J BEDROOM 4 K. BEDROOM 5 4,4" 31-8" x .21-511 .343D -x .2'.5" VAIN/STAIN STAIN/STAIN 64:ETI" GLAZING REQUIRED 1/A2.0 1/40 1/A22) 3/420 STAIN/STAIN '38"'x STAIN/STAIN SAW 3/A20 TYPICAL WINDOW SCHEDULE NOTES 1. NOTEWHERE SAFETY GLAZING IS INDICATED, BUT NOT soKEDuLED-. IN SECTION 05 8000, ALL UNLAM INATED GLAZING PANELS IN: THAT UNIT .ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED.LASS,BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED:GLAZING: PER CODE. 2. FIELD. VERIFY ALL EXISTING WINDOW opErspNopim.N$1QN, HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR! Fx7RI0R. WOOD TRIM, CONTRACTOR SHALL COORDINATE WITH HOMEOWNER FR100 TO :START OF WORK. .4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING, DETAIL 'A' ON WINDOW TYPES, SCHEDULE &.DETAILS.SHEET: 1" min. I/411 HEMMED EDGE. SLOPE 1 LEND c1-0SURE FLASHING HEAD DETAIL TYP. = - 0" (E) WP. 511,N CAREFULLY LIFT (E) WALL UNDERLAYMENT PENETRATION 'FLASHING. LAP (E) WALL AND INSTALL SELF-ADHERNG MEIIBRANE \1 YEN LIsIDERLAYMDIT OVER PENETRATION FLAWING. TYP AT HEAD AND JAMBS. •REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND. TRIM. REPLACE OR RE INSTALL SIDING AS Map. MAINTAIN CE) COURSING. YANT MoDIFIED SIDING TO MATCH (E) sons*. PRE -PRIMED, GAIN SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR To BE SELEcTED IN THE FIELD •TRIM- MATCH (E) MI. PRIME ALL SIDES AND PANT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT AcoUsTIcAL WINDOW •ASSEMBLY -REMOVE (E) WD. Nom: FOR. INSTALLATION OF NEW WINDOW TRIMS AND :REATTACRIENT OF E) SIDING To IUNDoLV OPENING.FRAMNG. LIFT (E.) WALL UNDERLAYMENT AND INSTALL WINDOW./ NAILING. FLANGE OVER SELF ADHERING MEMBRANE PENETRATION LASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT, GAUL NEW NegRTICAL, :SING JoNts .4 SET NAIL wEADs FLUSH. PAINT MODIFIED SIDING TO -MATCH: (E) SIDING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING. BACKER ROD 4 SEALANT ACOUSTICAL WINDOW AssEtax ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN TRIM- MATCH (E) TRIM. PRIME ALL WINDOW HEAD WINDOW JAMB (E) GLIB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE •TOUc4-1 UP PAINT, AS REaD CONTINUOUS SEALANT, •Trp. SOLID Wool:, TRIM WD. JAMB LINING SEALANT SI -IN AS NECESSARY PILL GAP W/ BATT INSULATION (E) TOUCH UP PAINT, AS REQ'D CONTINUOUS SEALANT, rrp. SOLID WOOD TRIM IllP JAMEs'.LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT 3/4" WOOD SILL SOLID WOOD. TRIM SIDES: AND PAINT TO MATCH (E) TRIM, COLOR TO BE FIELD DETERMNED REMOVE (E.) WOOD SIDING FOR INSTALLATION OF NEW. WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN COURSING. PAINT MODIFIED SIDING. TO MATCH (E) SIDING EXTERIOR 5IEATI-ING (E) WD SIDING CoNTINUoUS SEALANT, Mo. TOUCH UP PAINT, AS REQ1D SELF -ADHERING MEMBRANE WINDOW SILL WOODHSI DIN 37 - �IP W NDOW (E) GUS DETAIL SET (E) LC/. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION. •FLASHING. LAP (E) WALL UNDERLAYMENT OVER •PENETRATIoN FLASHING. TY o AT HEAD AND JAMS. REMOVE (E) wow SIDING FOR. INSTALLATION OF NEW WINDOW ASSEMBLY AND min RgPLACE w INSTALL SIDING 48:REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TaTIATC14. (E) SIDING. PRE-PRIMED,'GALV SHEET METAL FLASHING LU/ END CLOSURE UNDER SELF-ADIJERING MEMBRANE. COLOR TO BE SELECTED IN. THE FIELD TRIM - MATCH CE) TRIM. PRIME ALL SIDES AND PAINT TO MATCH CE) TRIM. COLOR To BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY CE) GUUB (E) WALL. UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE ,/,----TOUCH UP PANT, AS REQ'D CONTINUOUS SEALANT, Thio. REMOVE (E) WD. SIDING FOR INSTALLATION CF NEW WINDOW TRIMS AND REATTACHMENT OF (E) SIDNG TO WINDOW OPENING. PRAMIN6.: LIFT CE) WALL UNDERLAYMENT AND INSTALL:. WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL :SECOND LAYER OF SELF ADHERING •MEI1BRANE OVER NAILING FLANGE AND LAP UNDER (:E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH CE) (E) WI). SIDING CE) WALL INDERLAYMEtsIT (E) EXTERIOR SHEATHING BACKER ROD 4 SEALANT ACOUSTICAL uric= ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING. FIN WINDOW HEAD.. WINDOW JAMB SOLID WOOD TRIM LUD. JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP WI BATT INSULATION CE) CERAMIC TILE (E) GUJB CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM IUD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION 3/4" TRIM- MATCH (E) TRIM, PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD. DETERMINED REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN CE) COURSING. PAINT MODIFIED SIDING TO MATCH CE) SIDING (E) EXTERIOR SHEATHING (E) WP ...SIDING WINDOWSILL WOOD SIDING- - WI = NDOW BACKER ROD 4 SEALANT 3/4" WOOD SILL SOLID WOOD TRIM CONTINUOUS SEALANT, TY. SELF -ADHERING MEMBRANE CE) CERAMIC TILE (E)GUE DETAIL SET (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE. (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REO'D. MAINTAIN CE) COURSING. PAINT MODIFIED SIDING. TO MATCH (E) SIDING. PRE PRIMED, GALv SHEET METAL FLASHING W/ END CLOSURE UNDER. SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY REMOVE (E) too. SIDING FOR ji (E) WALL INDERLArIENT CE) IUD. PANELING (E) EXTERIOR SHEATHING SELF -ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM UP JAMB LINING ED INSTALLATION. OF NEW WINDOW TRIMS AND :REATTACHMENT QF(E) SIDING TO ANDDku .ippENIN4:m‘ArlING, LOT; CE) tuALL. UNDERLAYMENT AND INSTALL WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION PLASHING: INSTALL. sEcoNak,!.- JR: OF SELF ADHERING: MEMBRANE. NAILING FLANGE AND LAP UNDER (E). WALL1.41,112EIRLAYMENT..CAULKNEw VERTICAL SIDING JOINTS 4 SET NAIL HEADS. FLUSH. PAINT MODIFIEDSIDING. TO MATCH CE) ,sIpING (E) up. SIDING. (E) WALL UNDERLAYMENT CE) EXTERIOR SHEATHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT. WINDOW NAILING FIN WINDOW HEAD WINDOW JAMB SEALANT SHIM AS NECESSARY FILL. GAP W/ BATT INSULATION (E) WO, PANELING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM Luz) JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP U)/BATT INSULATION TRIM. MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED REMOVE CE) Loop SIDING BACKER ROD 4 SEALANT 3/4" WOOD SILL SOLID WOOD TRIM CONTINUOUS INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE. INSTALL SIDING AS REQ'D. MA NTAIN (E) COURSING. PANT MODIFIED SIDING TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WD. SIDING REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 ' City of Tukwila BUILDING DIVISION SEALANT, TYP. SELF -ADHERING MEMBRANE WOOD SI 3" = V - O" • WINDOWSILL DING -WI RECEIVED CITU OF TUKWIIA 'JAN 01 2013 OERMIT CENTER NDOW DETAIL SET S.MSTEMPER ARCHITECTS A iDeofeasional Limited Liability. Company 4000 DELIZIDGE WAY SW SUITE 260 • SEATTLE, WA 98106 (200) 624-V77 • FAX (206) 624-2973 • .STATF.. ,1;..i5•Of•an.IDN:' 0810.03.2231 JUNE 7, 2012 0 0z0 z ce LU z 0 0 (9 AI P NUMBER MPROVEMENTS ›- 0 LU LU LU C/) F- LU LU 3,53.0058-044 DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN. LB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2231 DOOR TYPES 0 PLUSH MU UP WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZNG W/ OBSERVATION• PORT 5 FLUSH sat) I LITE Wi 2 PANELS W/SAFETY GLAZING EXTERIOR SINGLE LEAF STORM WI SAFETY GRILLE DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE Wx H FINISH INT./ EXT. HARDI/VARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 2 !VIR0011 KITCHEN (INTERIOR) A 5 PANT/PANT PAINT/PAINT 141W,1 t'6IM DK -4 LOCK4 .1A21 / 6� DK -2 LOCK -I 2/A2.l 3 LIVING ROOM C x 1442.1 TYPICAL DOOR SCHEDULE NOTES 1. wHFRF SAFETY GLAZING- IS INDICATED,. BUT NOT SCHEDULE [N SECTION 0880 00; ALL LINLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE: TEMPERED. LAMINATED 'GLAZING PANELS: NEED NOT :CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING. PER CODE. 2. SLIDING GLASS DOORS: SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3, FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS, 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WoRK. 5. FOR ',HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A ON oiaoR. TYPES. SCHEDULES & DETAILS SHEET: •PI min. tritn., •HEMMED EDGE E HEAD FLASHING. DETAIL TYP. 3' = 1' - 0" (E) 1.10. SIPING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL. SELF-ADI-IERING MErIBRANE PENETRATION PLASwiNa. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FI-ASHING. rrp AT HEAD AND JAMBS. REMOVE (E) WOOD SONG FOR INSTALLATION OF NEW DOOR ASSEMBLY AND. TRIM. REPLACE OR RE INSTALL SONG AS REQ'D. MAINTAIN (E) COURSING. PANT MODIFIED SIDING TO MATCH (E) SoNct FRE -PRIMED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND. Z BAR FRAME STORM Dom PER SCHEDULE 2" MN. SELF-ADI-IERNG MEMBRANE (E) EXTERIOR SWEANINCs TOUCH UP PAINT AS, REQ'D ILI 3'. REMOVE (E) WD. SIDING FOR INSTALLATION OF NEW DOOR TRIMS AND REATTACHMENT OP (E) SIDING TO DOOR. OPENING FRAMING, LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH: (E) •SIDING (E) UOOD SIDING CONTINUOUS SEALANT BEHIND Z BAR FRAME sipRI:' DOOR PER:SO4EP:34E DOO R H EAD KEW AS REQUIRED POR WEATHER. STRIPPING INSTALLATION. CONTINUOUS WEATHER-STRIPPING JAMB BEYOND DOOR JAMB WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE WOOD SI 3" = 1' - On DI CONTINUOIA SEALANT, TYR .600D Loop: TRIM AS NECESSARY PILL GAP W/ :BATT INSULATION: II)M0 'PRAM KEW' AS:, REQUIRED OR. WEATHER: STRIPPING', INSTALLATION CONTINUOUS. WEATHER- STRIPPING, POOR PER SCHEDULE (E) EXTERIOR swEAll-ING. TOUCH UP PAINT, AS. REQ'D CONTINUOUS DOOR SILL NG - DOOR DETAI SET SEALANT, TYP. EXISTING FRAMING SOLID WOOD TRIM SHIM AS. NECESSARY PILL GAP W/ BATT INSULATION SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING. KE RP IN CONTINUOUS WEATHER STRIPPING. SHIM AS NECESSARY FILL GAP WI BATT INSULATION 000 BACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME SURFACE. APPLIED CONTINUOUS WEATHER SNIFFING KERS IN CONTINUOUS WEATHER STRIPPING. JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE AUTOMATIC DOOR SWEEP R HEAD TOUCH UP PAINT, AS REQ'D --- CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM INTERIOR DOOR. PER SCHEDULE EXISTING FRAMING —TOUCH UP PAINT, AS. REP DOOR JAMB CONTINUOUS sEALANT, TTP. SOUP WOOD TRIM DOOR PER SCHEDULE DOOR SILL INTERIOR - DOOR DETAIL SET 3" = 1' - 0" REVIEWED FOR CODE COMPLIANCE APPROVED 'JAN 1 1 City of Tukwila BUILDING DIVISION RECEIVE') MY OF TUKWA A 'JAN 0 7 2013 ...441,401 Coy tUO(3 S.ALST EEEEEEE ARCHITECTS A Profeasionai Limited Liability Company 4000 DELRID GE WAY SW SUITE 200 SEATTLE, YfA 98106 (06) 624-2777 • FAX (206) 624-2973 4220 /111 V 0810.03.2231 JUNE 7, 2012 0 0Fz_ LU KING COUNTY MPROVEMENTS 0 LU LU LU 0 z u_ U_I CI) LL1 AI P NUMBER 3-53-0058-044 z 0 Co DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP DOOR TYPES, SCHEDULE & DETAILS A2.1 010.03.2231 CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEM5R4NE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYp AT HEAD AND JAMS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF VENT FIXTURE AND FLASHING. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. pRE-PRIMED, GALv. SHEET METAL FLASHING LW FF. END CAPS UNDER SELF -ADHERING MEMI5R4NE. EXTEND FLASHING 4" UP WALL. PAINT COLOR To SE SELECTED IN THE FIELD PAINT VENTILATION FIXTURE, COLOR To SE SELECTED IN 114E FIELD EXTERIOR VENTILATION FIXTURE. REF. mEcI4.- PAINT INTERIOR LW ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. REMOVE REPLACE SIDING AS REQUIRED. ,a. ) it AIR INTAKE 3" = 1' - oR (E) WALL UNDERLAYMENT SELF ADHERING MEMMONE (E) EXTERIOR SHEATHING 2X BLOCKING 2X2CONTINUOUS PRESSURE TREATED ELOCKNG, 4 SIDES DETAIL AT EX ERI 2X BLOCKING OR. (E) WALL FRAMING BLENDING AIR UNI 1 112"= i' -O" CEILING 1=n MST HERE DETA >-‹ L 4"MIN ACCEPTAKE HERE NOTE: REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK., TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ItIZ I NEW BLENDING UNIT SIDE WALL SMOKE DETECTOR INSTALLATION. DETAIL. - On REVIEWED FOR CODE COMPLIANCE APPROVED ' JAN 11 •mil City of Tukwila BUILDING DIVISION 41) —cs (3 RECEIVED CITV OF Ttomitul JAN .072013 .‘RMIT CENITIPP SiMSTEMPER ARCHITECTS A PfiafeasiOnal Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, TITA 95100 (206) 624-2777 • FAX (206) 624-2978 ........ 0810.03.2231 JUNE 7, 2012 MPROVEMENTS ›- 0 LULU2 ct 1.1.1 CO 0 z AIP NUMBER 3-53-0058-044 z 0 0 z CO DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN. LB&CP MISC. DETAILS A2.2 0810.032231 LIFT (E) MPG. PAPER AWAY LOOSELY FROM CE) SHEATHING AT JAMBS AND HEAD BUTTERFLY coReRs, TYR NOTE: REMOVE f E) SIDING BACK PROM CE) Ra AS REM:, (E) SIDING NOT SHOWN FOR cI.ARIrr. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED 12" LAP SILL MEMBRANE FLASHING 2-I/2" OVER (E) BLDG. PAPER AT SILL. ExtEND I in BEYOND R.O. AT EA. END OF SILL. CE) BLDG. PAPER AT SILL CE) CUT SILL FLASHING 4 FOLD THROUGH RO. AS SHOW( ADHERE MEMBRANE FLASHING TO OUTSIDE PACE OF WALL SHEATI-ING li" MIN TYP. MEMBRANE FLASHI NG AT SILL BUTTERFLY CORER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOW FOR CLARITY, NOTE; REMOVE CE) SIDING BACK FROM CE) R.O. AS REQD (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR. INSTALL NEW SIDING AFTER MEMBRAI•E FLASHING HAS SEEN NSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAP AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL CE) EsLPG. PAPER AT SILL. a a a ELEVATION VIEW NOTE: INSTALL WINDOW PER MFGRS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENI1sIGS, BEND ANCHORAGE NAILS DOLUNI ------ OVER NAIL FLANGE, HEAP ONLY, WINDOW MEMBRANE I NSTALLATION CE) SHEATHING SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQD CE) SIDING NOT SHOUN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING_ AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. • WHERE REamo, TRIM CE) 'BLDG PAPER AT HEAP TO PREPARE FOR. INSTALLATION OF HEAD FLASHING AND IUNDOW TRIM. (FOLLOWING STEPS). HEAD FLASHING PRE SCALE: NTS PA RATION CE) BLDG. PAPER NOTE: REMOVE CE) SIDING BACK FROM CE) RD. AS REQ'D CE) SIDING NOT 51-1004 FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1448 BEEN INSTALLED. 44/2" T'YP. MEMBRANE FLASI II CUT JAMB• FLASHING 4 FOLD AROUND WINDOW OPENING AS 5140111. EXTEND I-1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING NG AT JAMB SCALE: NTS NOTE: REMOVE CE) SIDING. BACK FROM (E) RO. AS REQD (E.) SIDING NOT SI-10UA FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED, INSTALL WT. METAL HEAD FLASHING UNDER CE) BLDG PAPER TRIMMED EDGE OF CE) SIDING, SHOUN DIAGRAMATICALLY. CE) SIDING NOT SNOW. FOR CLARITY. - INSTALL JAMS FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASH jSCALE: NTS INC AT JAM B NOTE. REMOVE (E) sipING Imo< (E) RD. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY, REPLACE AND OR INSTALL NEW SIDING. AFTER MEMBRANE. FLASHING HAS SEEN INSTALLED. ALLOW lie' BETWEEN F 130T. \\\\\\\\\\\\ CLEARANCE ASI-ING AND EDGE OF (E) SIDING. HEAD FLAS SCALE: NTS H ING INSTALLATION CE) BLDG. PAPgR, MEMBRANE F LASHING AT HEAD CUT HEAD FLASHING 4. FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND I-1/2" BEYOND R.O. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) SCAL E: NTS NOTE: REMOVE (E) SIDING BACK 'FROM: re) Ito. AS REQ'D :(E) SIDING. NOT SHOWN FOR CLARIrl. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. / ;14* 0-71e t.;'• \ 0 x*. N WINDOW F SCALE: NTS. LASHING NSTALLATION SHEET METAL HEAD FLASHING WOOD TRIM INSTALLATION SCALE: NTS (E) SIDING CE) BLDG. PAPER BENEATH SIDING INSTALL Up. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) sorsa APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND LEAVE I/4"-3/8" GAP BETWEEN WINDOW. TRIM AND WINDOW FRAME INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: MEMBRANE PLASHING 15 SPECIFIED IN 01 62 00 AS "SELF APHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS 9, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW •NETTALLATION 3: DETAILS "5 AND 6" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, a-ummEo, AND ANCHORED. 4: DETAILS I AND El" REFER TO SHEET METAL. HEAD FLASHING. 5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK JOINTS. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 11 .)nil City of Tukwila BUILDING DIVISION 013 RECEIVED CITY OF TuKwo JAN ,0 7 2013 c'ERAMTCEITMi;. S.MSTEMPER ARCHITECTS A Professional Limited Liability company 4000 DELRIDGE WAY SW SUITE .200 SEATTLE, WA 98106 (2oe) 624-2777 • FAX (206) 624-2973 0810.03.2231 JUNE 7, 2012 0 0_ rt —J z z UI 2 z 0 0z MPROVEMENTS › - LU UI2 LU CO 0 UI CO AI P NUMBER 3-53-0058,044 DATE JUNE 7, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&T'F DRAWN LB&CP WINDOW FLASHING DETAILS A2.3 0810.03.2231 ACM ACU AFC AFF APPROX ARCH ASH RAE BFC BFF BOD BTUH CD CFM CIRC CON D CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV. EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ABBREVIATIONS ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED. FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR :CONDITIONINGENGINEERS BELOW: FINISHED CEILING. BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING: EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND, DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING. VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING' MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR, OUTSIDE AIR TEMPERATURE ON CENTER, OPPOSED BLADE DAMPER PHASE POINT OF"CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN. GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS SEATTLE RESIDENTIAL CODE' TOTAL DYNAMIC HEAD TOP OF. DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL LEGEND DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN XX OR a. 0 X/Y 7/////////, DIRECTION OF CUTTING PLANE SECTION CUT LINE 111111•111111•111111•11•111.4 DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE. NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE DRAWING INDEX 41,0 LEGEND, SCHEDULES,. ABBREVIATIQN:S, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS AND DETAILS. GENERA L NOTES 1.: THE MECHANICAL .SYSTEM SHALL: CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR. PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK: INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING,TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. -PROVIDE A COMPLETE AND. OPERABLE MECHANICAL SYSTEM ,COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED. BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS: ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE., COORDINATE THE INSTALLATION 'WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DOE TO PRODUCT SUBSTITUTION, 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. 7. 8 9. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND. CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, THERMOSTATS 4Y-0" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIP 10. MAINTAIN 1O' -O" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTL 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN S-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. THE ELECTRICAL CONTRACTOR. WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, MENT. ET. SYtv1BOL 5G -X XXX 44 .M.0.40,:§70' DMRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT S FLEX CONNECTION VP,P,0111 .L_ VD VOLUME DAMPER RA/EA RETURN AIR OR EXHAUST AIR DUCT RG RETURN AIR GRILLE SA SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RA/EA RETURN AIR OR EXHAUST AIR DUCT SA SD. SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH EQUIP IDT1/4,....C:R THERMOSTAT CP, -----EQUIPMENT LOCATION NG • a 0 MOD NG MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE, APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUI REMENT M ECH AN ICAL / EL ECT R ICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT VOLTS PH FURNISHED DES CRI PTI ONUNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION 23 26 23 26 N/A 23 26 N/A REMARKS: BV -I, 2 BLENDING UNIT VENTILATOR 120 X x 1,2 SWITCHES (ON, TIMER) 120 X X X REMARKS: I - VERIFY QUANTITY FROM PLANS (TYPICAL -ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL WATTS VOLTS PHASE COMMENTS BVI 165 .5" WG 32"Lx12.25"WX8.5"H 76 120 I, 2, 3 BV -2. 140 .5" WG 32"Lx12. 25"Wx8...5"H 76 120 I, 2, 3 NOTE: I. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF IDESIGN: ALDES AMERICAN. A. OR:,APPROVED, EQUAL. GRILLE AND DIFFUS ER SCHEDULE MARK CFM sTATic PRESSURE INLET OR NECK SIZE DUCT CONNECT] ONI LOCATION M OPEL # REMARKS 1.65 wq 8" CEILING ALLeRILLE• 4 SG -2 140 <.08" WO 8" CEILING ALLGR1LLE 1, 2, 4 OG -I 90 <,..QV INC 7, 7" WALL WALL CAP 2 3, A OG -2 90 <.. 0.8 WO 7" .7" WALL WALL CAP I„ 2„ 3, 4 .IRG-1 25 ‹,08" WG 4" 4" WALL DECO 1, 2, 4 RG -2 25 <Age"-• WS 4." 4" CEILING DECO 1, 2, 4 REMARKS: I. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2 PAINT TO ,BE •COORDINATED WITH TECHNICAL REPRESENTATIVE 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 5. BASIS :6F DESIGN: ,SHOEMAKER A. OR APPROVED. EQUAL, 6. PROVIDE WITH AN: OPPOSED BLADE DAMPER WAC RESIDENCE CODE' FLOOR AREA SQ . FT.) *NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810. 03.2231 BV -I 808 3•' .0 CFM 90 CFM 0810.05.2231 BV -2 139-3 2. 90 CFM 90 CFM I. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51-51-1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS UCT LOCATION MIN VALUE NOTES N ROOF OR ON EXTERIOR OF BUILDING R-8 WITH WEATH ERPROOF BARRIER TTIC GARAGE. CRAWL. SPACE, IN WALLS. IN FLOOR/CEILING R-8 1.2.3 ITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R-8 3 CEMENT SLAB. OR IN GROUND R-5 1.3 1 OTES: THICKNESS OF INSULATION IS DEFINED AS, THE THICKNESS OF THE BASIC INSULATING EDIUM NOT INCLUDING FINISHING MATERIALS. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH LOCATED WITHIN A WALL DR LOORicEILING, SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND HERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR. • . REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWN G NO ES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND :WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL .AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01 1101 AND 028200 FOR REGULATED MATERIALS ABATEMENT, 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT. :SWITCH HOURS. QF OPERATION SET BV -1. BV -2 SWITCHES TO OPERATE 1 OF EVERY 2 HOURS. BV -1. 2' MECHANICAL VENTILATION CALCULATION PER WAC 51-51 M1508.3: QF = QR (11i:EGR X F) QR = (FROM TABLE M1508.2) 45., &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1/2) =.901 CFM b (3-013 F?EPA RA TE ERMITAIVrt APPPO VAL ‘f REQUIRED RECENED CITY OF Toonnt.A 1JAN 07 2013 .40.0 CENT h'•' EXPIRES: 9/08/2012 S . M. STEMPER ARCHITECTS A Prate:eons) Waked Ilabill14 Company 4000 DELRIDGE WAY SW SUITE 200- SEATTLE. WA 08106 (goo) e24,27/7 FAX (ne) est-eirre THE GREENBUSCH GROUP, INC 000 00 0400 011012111K, AUDIO./ Mee& MECIWAGAL ENGINEERING 100 VEST NOMA STREET SATE 201 SEATTLE, We 00119 (200) 370-0510 (200) 3711-01141 FAX 0810.032231 FT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3-5$-0050-044 DATE 06/05/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, CHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1 .0 0810.03.2231 LAUNIPR'r ATI -1 KITCHEN D IN ING ROOM TV ALL CEILING GRILLES: TO BV -2 L IVING ROOM $G-2 140 5EOROOM 2 ---*Ns MAIN FLOOR MECHANICA L GARAGE PLAN SCALE: 1/4" = 1* -0" RETURN AIR DUCT OUTSIDE AIR DUCT HOLD TIGHT TO STRUCTURE MOTOR ACCESS FILTERS. ACCESS SUPPLY DUCT •BV -1 NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION!. 2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE BV 1, 2 SCALE: NONE NSTALLATION DETAIL SHEETMETAL TRANSITION TO WALL CAP NECK SIZE DUCT. PER PLAN CAULK 2X BLOCKING NOTES: 2X BLOCKING FOAM BACKER ROD WALL CAP SLEEVE AND ESCUTCHEON WALL 1. INSTALL PER MANUFACTURER'S :WRITTEN INSTRUCTIONS. 2„ SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3.: COORD. W./ARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1./AZ2 FOR DETAIL WALL CAP DETAI L SCALE: NONE CAULK UPPER FLOOR. SCALE: 1/4 = V-0” SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT :PER PLAN 2X BLOCKING. MECHANICA L 2X BLOCKING PLAN FOAM IEIACKR ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES:. 1. INSTALL :PER MANUFACTURER'S *WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3 WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. WALL GRILLE DETAIL SCALE: NONE. NORTH SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE 2X BLOCKING SLEEVE AND ESCUTCHEON GRILLE DUCT PER, PLAN COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE FOAM BACKER ROD CAULK 2X BLOCKING FLOOR OR CEILING JOIST • CEILING NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEI LING GRILLE DETAIL SCALE: NONE 1. MAIN •I 1 f .41 1; 111 UPPE 11 I 1 1 I I I 1 I :I I •BV 2 UPPER FLOOR MECHANICAL SCALE: 1/4" = 1'-0" DRAW NG NOTE ' PLAN GfNORTH FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51, SECTION M1508.6.6. 2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEMS WITH NEW FILTERS. FLAG NOTES: 130 13 BV -1. BV -2 AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL AND. MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51, SECTION ,.M1508.6.4. COORDINATE FINAL SWITCH LOCATION WITH HOMEOWNER. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION., PROVIDE CUTIING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. SEPARATE PERMITAND APPROVAL REQUIREDRECEIVED CITV OF TUKWILA 1JAN 0 7 2013) PERMIT CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS Protteakmal LIAAteral LIAMI.My ontapsav 4000. DERIDGE WAY SW svat 200 SFATI1W, W4 81O (OA) 624-2777 • PA.X (O 624,4205 THE. GREENBUSCH GROUP, INC )))41110...4 ACOUM1CAL. #apio / vIZO k MECHANIC& DICIMERINC 100 IMM` tlCN 91!r SINE 201 SWIM SA $0119 (206) 375-05119 (200) 378-01141 FAX 0810.03.2231 MPROVEMENTS RESIDENTIAL Al AIP NUMBER 3-53-0056-044 DATE 06/05/2012 • ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL. FLOOR PLANS AND DETAILS M200 0810.03.2231 ELECTRICAL - PROJECT NOTES 1, CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ft! -4L. ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME: PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE; INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3, MAXIMUM POWER OUTAGE IS TO BE NO LONGER: THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH. UNIT BEFORE St.DO AM & AFTER 5:00 PM, 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND. PATCH AS REQuIRED, REMOVE ALL PAINT LINES, PROVIDE: SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW 'ROUGH IN. PAINT TO MATCH SURROUNDING CONDITOn. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION, PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORD NATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. 0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE: SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. T r DEMO EXISTING PANEL. USE AS JUNCTION BOX. EXTEND EXISTING CIRCUITS TO NEW PANEL KITC:1-41 t:)INNa 0011' "71-1:7•1OOM N. NEW PANEL. SEE DETAIL AND PANEL SCHEDULE .1: it rt- MAI N FLOOR PLAN 1/4" = METER AND FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY CHARGES IN BID. PROVIDE NEW METER BASE, RIGID STEEL MAST, WEATHER HEAD AND CONDUCTOR PIGTAILS PER SCL REQUIREMENTS. FINAL \CONNECTIONS BY SCL. INCLUDE ALL UTILITY SERVICE FEES IN BID. PROVIDE NEW WEATHER HEAD, MAST GUYS AND ANCHORS AT EXISTING LOCATION. PROVIDE NEW ROOF FLASHING. NORTH VEGETATION TO te" PROVIDE MINIMUM 36" CLEARANCE AROUND SERVICE WIRES PER SCL REQUIREMENTS. ELECTRICAL LEGEND SY11501. DESCRIPTION SYMBOL DESCRIPTION IJGHTING OR POWER PANEL BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS, (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL. INDICATES EQUIP CND. INDICATES ISOLATED GROUND. 0 vesummsepw— MAST, WEATHERHEAD BRANCH CIRCUIT HOME RUN EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. DAMPER CONNECTION NON-FUSED DISCONNECT SWITCH TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS SMOKE DETECTOR ELECTRICAL METER TIMER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. CEILING MOUNTED FIRE. ALARM -VISUAL STROBE LIGHT THERMOSTAT UNE VOLTAGE. FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR MECHANICAL ELECTRICAL C00- 'NATION ITEM NO, EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURNISHED UNDER DIVISION INSTALLED UNDER DIV SION WIRED UNDER DIVISION 15 16 15 16 N/A 15 16 N/A REMARKS BV -1 BLENDING UNIT VENTILATOR 120 1 X X 1,2 SWITCHES (ON, TIMER) 120 1 X X 1 REMARKS: 1 - VERIFY QUANIIIY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH I 5.E.E)Re,ai ("1--ITINEY AFF 3EDIROcts-1 FPIOCM RECEIVED CITY OF MIMI, A JAN 0 7 2013 T r;$ s..MSTEMPER ARCHITECTS A Prof essional Limited Liability Company 4000 DELFUDGE WAY SW SUITE 200 •SEATTLE , WA 98100 (208) 824-2777 • FAX (206) 624-2973 0810.03.2231 AIP NUMBER MPROVEMENTS — z w 0 w ce 5-53-0058-044 DATE JUNE 7, 2012. ISSUED. 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 C1810.03.2231 PAN EL p 120240 VOLT. SERVI NG: RESIDENCE ...... .......... . . ......... . .. 10,000 AIC. 1. 200 PHASE, 3 WIRE. AMP with MAIN BKR CKT LOAD D ESCRIPTION TYPE NP PHASE KVA TYPE LOAD tle$001Frpc CKF 1 EXISTING LOAD 5 " EXISTING LOAD 5012 4612 A A B 4012 20/2 EASTING LOAD EXISTING LOAD 2 4 7 9 EXISTING LOAD 11 • 111 20/2 a 2012 EXISTING LOAD 10 13 EXISTING LOAD .16 EXISTING LOAD EXISTING LOAD la,,:EXISTkOLoActi. 23 20/1 2on 20/1 2011 A 20/1 EXISTING LOAD 14 A A A 20/1 20/1 26if • 20/1" EXISTING LOAD EXISTING LOAD EXISTING -WAD isLENONG UNIT 16 IS 20 22 24 ..„ . < . 26 A 28. 30 31 A B 32 35 36 37 • A A 36 42 LOAD TYPE A LM TOTAL LOAD CONN< LOAD KVA COMPUTED LOAD KVA AMP ISOLATED GROUN BUS FEED THRU LUGS FNWITIPiTtla160ftigil CLOSU RE 0 DOUBLE LU GS MAIN BKR SHUNT TRIP ......... . PANEL:8KIRTE 0 Kfiyipa:IgNIRmo E 1.4,BEL. INTEGRAL TVSS SURFACE DEFLUSH PROVIDE NEW RIGID STEEL MAST, WEATHER HEAD AND CONDUCTOR PIGTAILS PER SCL REQUIREMENTS. FINAL CONNECTIONS BY SU- INCLUDE ALL UTILITY SERVICE FEES IN BID. PROVIDE NEW MAST GUYS AND ANCHORS rROOF PROVIDE NEW SERVICE ,\ DROP FROM POLE TO • HOUSE BY SCL. ALL ----"\ FEES PAID BY CONTRACTOR. •27C,. 3#3/O CU METER AND FINAL CONNECTIONS .BY SCL. INCLUDE ALL UTILITY CHARGES IN 1310.. PANEL MP 200A 120/240 1 -PH, 3W 2°C, 3#3/O CU.& GND PROVIDE METER BASE PER SCL STANDARD iyou13-4MAT-30 #4CU GROUNDING ELECTRODE CONDUCTOR AND GROUND RODS PER CODE. MAX 10 OHMS TO GROUND \ PROTIDE NEW NEMA -3R S.E. RATED PANEL BOARD. INTERCEPT AND EXTEND EXISTING aRCU TS AND CONN CT TO NEW BREAK RS. PROVIDE ALL REQUIRED CUTTING AND PATCHING AS REQUIRED TO COMPLETE THE WORK AS DESCRIBED ABOVE AND ON DRAWINGS. ROUTE CONDUIT EXPOSED ON OUTSIDE OF HOUSE. PROVIDE STRUCTURAL SOLID 2X6 BLOCKING IN ATI1C FOR MAST. PROVIDE BLOCKING AND UNISTRUT ASSEMBLIES TO HOLD CONDUIT AWAY FROM HOUSE SURFACE TO ALLOW FOR EXISTING CONDITIONS. VISIT THE SITE TO ESTABLISH EXACT CONDITIONS PRIOR TO BID. NEVV SERVICE DETAIL SCALE: NONE SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED CITY OF TUKWILA I JAN ,0 7 2013 PERMIT CENTEF S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 400.0 DELRJDGE WAY SW SUITE 300. • ,STATTLE, WA 98100 (206) 624-2777 • FAX (206). 624-2973 INOINIIMRS. IMO 111113 OMR 4810 WIER SON wow& stk visisom 1001011 as mottos 1011 0810.03.2231 NTERNATIONAL AIRPORT z 0 0 0 MPROVEMENTS AIP NUMBER. 5-53-0058-044 SEATTLE WASHINGTON DATE. JUNE 7, 2012 ISSUED 100% PROJECT ENGINEER PROJECT MANAGER SCR DRAWN JAB FLOOR PLANS NOTES E1.1 0810.03.2231