HomeMy WebLinkAboutPermit D13-019 - CITY OF TUKWILA - POOL - REROOFCITY OF TUKWILA
POOL
4414 S 144 ST
D13-019
City Ilk Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: htto://www.TukwilaWA.gov
Parcel No.: 1523049106
Address: 4414 S 144 ST TUKW
Suite No:
Project Name: CITY OF TUKWILA - POOL
DEVELOPMENT PERMIT
Permit Number: D13-019
Issue Date: 04/12/2013
Permit Expires On: 10/09/2013
Owner:
Name: TIIKWILA SCHOOL DISTRICT
Address: 4640 144TH ST , SEATTLE WA 98168
Contact Person:
Name: ROBERT EATON
Address: 12424 42 AVS , TUKWILA WA 98168
Contractor:
Name: BATE'S ROOFING LLC
Address: PO BOX 9416 , TACOMA WA 98409
Contractor License No: BATESRL945JO
Lender:
Name: CITY FUNDED
Address:
Phone: 206 767-2332
Phone: 253-473-0675
Expiration Date: 04/20/2014
DESCRIPTION OF WORK:
REROOF: APPLY A RUBBER/PLASTIC TMO ROOFING SYSTEM OVER THE TOP OF EXISTING TORCH DOWN ROOF. THE
PRODUCT WILL BE GLUED DOWN. NEW FLASHING WILL BE APPLIED ON WHOLE ROOF.
Value of Construction: $100,000.00 Fees Collected: $2,433.96
Type of Fire Protection: AFA International Building Code Edition: 2009
Type of Construction: Occupancy per IBC: 0007
Electrical Service Provided by: SEATTLE CITY LIGHT
**continued on next page**
doc: IBC -7/10
D13-019 Printed: 04-12-2013
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
N
N
N
Number: 0
Start Time:
Volumes: Cut 0 c.y.
Start Time:
Private:
Profit: N
Private:
The granting of this permit does not pres
construction or the performance of work.
to this permit.
Signature:
Print Name:
Date:
Size (Inches): 0
End Time:
Fill 0 c.y.
End Time:
Public:
Non -Profit: N
Public:
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this development permit and agree to the conditions attached
lfutat%j
Date:4/II Z'/i?j
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431-3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate
shall be provided to the building inspector.
doc: IBC -7/10
D13-019 Printed: 04-12-2013
7: VALIDITY OF PERMIT: The issuance orrnting of a permit shall not be construed to b ermit for, or an approval of,
any violation of any of the provisions of t1W1ding code or of any other ordinances oft ty of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D13-019 Printed: 04-12-2013
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: 4414 South 144th Street
Tenant Name: Tukwila Pool
PROPERTY OWNER
Name: Robert Eaton
Address: 12424 42nd Ave S
Name: Tukwila MPD
Phone: (206) 767-2332 Fax: (206) 767-2347
Email: robert.eaton@tukwilawa.gov
Address: 4414 S 144th St
City: Tukwila
State: wA
Zip: 98168
CONTACT PERSON — person receiving all project
communication
Name: Robert Eaton
Address: 12424 42nd Ave S
City: Tukwila State: WA Zip: 98168
Phone: (206) 767-2332 Fax: (206) 767-2347
Email: robert.eaton@tukwilawa.gov
GENERAL CONTRACTOR INFORMATION
Company Name: TBD i -('S R 1n t\ LL- C -
Address: 'Po iny c L o
City: I c ((r ck State: �xrH Zip: 18-109
.2.c.2-,-5 433 Dv15 Fax:
Contr Reg No.: (,,0-2 - t..) 5-_ 37-7 Exp Date:
Tukwila Business License No.:
H'.\Applications\Forms-Applications On Line \2011 Applications\Fermit Application Revised - 8-9-I l.docz
Revised' August 2011
bh
King Co Assessor's Tax No.: 1523049106
Suite Number: Floor:
New Tenant: ❑ Yes m ..No
ARCHITECT OF RECORD
Name:
(in‘l
1
Company Name:
Address:
Architect Name:
Address:
State:
City:
State:
Zip:
Phone:
Fax:
Email:
ENGINEER OF RECORD
Name:
(in‘l
1
Company Name:
Address:
Engineer Name:
Address:
State:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name:
(in‘l
1
. ` /l�
M y O
Address:
City:
State:
Zip:
Page 1 of 4
BUILDING PERMIT INFORMATION 4 206-431-3670
Valuation of Project (contractor's bid price): $ 100,000
Describe the scope of work (please provide detailed information):
Apply a rubber/plastic TMO typr roofing product over the existing torch down roof at the Tukwila Pool.
Existing Building Valuation: $
Will there be new rack storage? ❑ Yes
m.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of.
Occupancy 'per
IBC
1st Floor
15,000
CMU
Recreation
2md Floor
3f° Floor
Floors thru
Basement
Accessory Structure*-,
Attached Garage
Detached Garage
Attached Carport
Detached Carport",
Covered Deck ,.
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: 16 Compact: Handicap: 2
Will there be a change in use? ❑ Yes Z No If"yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
0 Sprinklers Z Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? Z Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8-I/2"x II " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9-1 I.docx
Revised: August 201 I
bh
Page 2 of 4
PUBLIC WORKS PERMIT INPARTMATION — 206-433-0179
Scope of Work (please provide detailed information):
Contractor to apply a TMO roofing system over the top of existing torch down roof at the Tukwila Pool. The product will be glued
down. N fl h l n j w i th Ize. Cy of ed trn w No ie. rb04
Call before you Dig: 811
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
El ...Tukwila ❑...Water District #125
❑ ... Water Availability Provided
Sewer District
❑ ...Tukwila
❑ ...Sewer Use Certificate
❑ .. Highline
❑...Valley View ❑ .. Renton
... Sewer Availability Provided
❑ .. Renton
❑ .. Seattle
Septic System:
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with Application (mark boxes which apply):
❑...Civil Plans (Maximum Paper Size -22" x 34")
❑ ...Technical Information Report (Storm Drainage)
❑ ...Bond ❑ .. Insurance ❑ .. Easement(s)
Proposed Activities (mark boxes that apply):
❑ ...Right-of-way Use - Nonprofit for less than 72 hours
❑ ...Right-of-way Use - No Disturbance
El ...Construction/Excavation/Fill - Right-of-way ❑
Non Right-of-way ❑
❑ ...Total Cut
❑ ...Total Fill
cubic yards
cubic yards
❑ .. Geotechnical Report
0 .. Maintenance Agreement(s)
❑...Traffic Impact Analysis
❑ ... Hold Harmless — (SAO)
❑ ... Hold Harmless — (ROW)
❑ .. Right-of-way Use - Profit for less than 72 hours
❑ .. Right-of-way Use — Potential Disturbance
❑ .. Work in Flood Zone
❑ .. Storm Drainage
❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor
❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization
❑
... Frontage Improvements ❑ .. Pavement Cut ❑ .. Trench Excavation
❑ ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding
❑ ...Backflow Prevention - Fire Protection
Irrigation "
Domestic Water
o ...Permanent Water Meter Size... WO #
❑ ...Temporary Water Meter Size .. WO #
❑ ...Water Only Meter Size WO # ❑ ... Deduct Water Meter Size
❑ ...Sewer Main Extension Public ❑ Private ❑
❑ ...Water Main Extension Public ❑ Private ❑
11
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment
Monthly Service Billing to:
Name: Day Telephone:
Mailing Address:
City State Zip
Water Meter Refund/Billing:
Name:
Mailing Address:
Day Telephone:
City
State Zip
H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 I.docx
Revised: August 2011
bh
Page 3 of 4
•
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER THORIZE AGENT:
Signature:
0z - LL
Print Name:
Mailing Address: 12424 42nd Ave S
H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised • B -9-I I.docx
Revised: August 2011
bh
Date: ``/y.( 3
Day Telephone: (206) 767-2345/
Tukwila WA 98168
City State Zip
Page 4 of 4
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.gov
Parcel No.: 1523049106
Address: 4414 S 144 ST TUKW
Suite No:
Applicant: CITY OF TUKWILA - POOL
RECEIPT
Permit Number: D13-019
Status: APPROVED
Applied Date: 01/15/2013
Issue Date:
Receipt No.: R13-01305
Initials: JEM
User ID: 1165
Payment Amount: $1,476.90
Payment Date: 04/12/2013 11:31 AM
Balance: $0.00
Payee: PARKS: PA#11263001.1000.107, GL#633.98.594.760.41.00
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Other
Authorization No.
ACCOUNT ITEM LIST:
Description
1,476.90
Account Code Current Pmts
BUILDING - NONRES
STATE BUILDING SURCHARGE
000.322.100
640.237.114
Total: $1,476.90
1,472.40
4.50
Drinlerl• !U_�9_9l111
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.gov
Parcel No.: 1523049106
Address: 4414 S 144 ST TUKW
Suite No:
Applicant: CITY OF TUKWILA - POOL
RECEIPT
Permit Number: D13-019
Status: PENDING
Applied Date: 01/15/2013
Issue Date:
Receipt No.: R13-00316
Payment Amount: $957.06
Initials: JEM Payment Date: 01/15/2013 09:55 AM
User ID: 1165 Balance: $1,476.90
Payee: PARKS: PA # 11263001.1000.107, GL # 633.98.594.760.41.00
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Other
Authorization No.
ACCOUNT ITEM LIST:
Description
957.06
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 957.06
Total: $957.06
'Inn• Dernin4_f1A
PrintMrl• 01-1F-9013
�-i
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
D -0 19
Project:
/
Type of Inspection:
Address;1 I . �. L , /
C�
jecial
SI
Date Called:
Special Instructions:
Date Wanted-
- iZ%1315
a.m.
Re qC+estO J t C A tbvv
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
3 -- 0 l
'& YVl a e ->u v -
\j. » R c11 0 211.
Ete
;ILmL
R INSPECTION FEEREQUI ' D. Prior to next i lspection. fee must be
pad at 300 Southcenter Blvd Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retaina copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 x(206) 431-3670
Permit Inspection Request Line (206) 431-2451
PERMIT NO.
Project:
M TH O -ru rc.,..01 A
Type of Inspection:
t---� AL.
Address:
LI Lity S ILiLi S1 --
Date Called:
Special Instructions:
NOL.. R€—ROC7ir
Date Wanted:
—7 --
11— l
a.m:
Requester:
Phone No:
E1Approved per applicable codes. D.Corrections required prior to approval. >
COMMENTS:
IQ 0 C. 14-n J gu .( e-Ach-o?
t h Lel 1` (e. ,.) CA
Inspe or:
Date:
I
INSPECTION FEE R QUIRED. Prior to next inspection. fee must be
id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 :: (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
05-7- LI car —a(
Type of Inspection:
Po - g 4 ZOL?T--
Address:Date
t -I q 1'-( S 1 y ("(
Called:
Special Instructions:
Date Wanted:.
t--1-- I
-r i
a.m;
-m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspecta
w14
rA
C REINSPECTION FEE REQ IRED. Prior to ext inspection; fee must
paid at 6300 Southcenter Bl d.. Suite 100. Call to schedule reinspection.
Thermop/ast/cSlog/e RlyandAhz/EN:fr
Roo114,ce f terpiafingSyste✓ns
Warranty # 914124
b13-019
Material & Workmanship Warranty
FLEX MEMBRANE INTERNATIONAL CORP. ("Flex") warrants to the Building Owner named below, subject to the terms, limitations,
and conditions set forth herein, for a period of 20* years, in which this Materials and Workmanship Warranty is effective, the Flex Roofing
Materials installed on the Building Owner's building at the address and location shown below, shall be free from defects in materials
supplied by Flex and/or defective workmanship provided by the Flex Authorized Applicator named below. *NO DOLLAR LIMIT
TERMS, LIMITATIONS, CONDITIONS
1) Installation of the Flex Roofing Materials must have been performed by a Flex Authorized Applicator and must have been inspected and
approved for warranty by Flex. This warranty issuance will not relieve the Flex Authorized Applicator from performing additional work
should final inspection discover any failure to comply with Flex current specifications and details or shortcomings in workmanship. This
warranty is effective and valid only after final inspection and acceptance by.Flex.
2) If, after inspection by Flex, leaks in the Flex Roof System are found by Flex to be the result of defects in Flex materials and/or the workmanship
of the below named Flex Authorized Applicator in the installation of Flex's material, Flex will repair any leaks in the roofing system at its
expense.
3) The warranty stated herein is the SOLE AND EXCLUSIVE REMEDY for defects in or failure of the materials supplied by Flex and/or
defective workmanship provided by the below named Flex Authorized Applicator. Flex shall under no circumstances be liable for damage
to the substrate (deck and insulation). the structure itself. contents of the structure. any other property. iniury to persons or for any
consequential damages or incidental damages or loss of any kind whatsoever, whether in contract or tort, including negligence.
4) This warranty does not cover failure of Flex Roofing Material if in Flex's good faith determination, the failure was caused by:
a) Natural disasters including, but not limited to, the direct or indirect effect of lightning, gales, earthquakes, floods, hail, fire, hurricanes,
tornadoes, or other extraordinary natural occurrences.
b) Vandalism, acts of war, mechanical damage or abuse, traffic or storage of material on roof, negligence, accidents, structure
settlement, defects or failure in other material or application of other material not supplied by Flex.
c) Metal work or other material not furnished by Flex or any workmanship not performed by a Flex Authorized Applicator.
5) This warranty does not apply and shall be null and void if any of the following occur:
a) Failure of Building Owner to confirm each leak event in writing to Flex, at the below address, within thirty (30) days of discovery
of each leak in the Flex Roof System.
b) Failure of Building Owner or his lessee to use reasonable care in maintaining the roof, including that of sealants and caulking.
c) Additions, alterations, or repairs made on or through the roof or to any area or surrounding area affecting the roof, other than those
approved in writing by Flex.
d) Failure of Building Owner, named below, to comply with every term, limitation, and condition stated herein.
6) During the term of this warranty, Flex, its agents and employees shall have free access to the roof during regular business hours to
perform appropriate inspections and repairs authorized by Flex.
7) Flex shall have no liability under this warranty until all bills for installation, supplies, and service have been paid in full to the applicator of
Flex materials and all material suppliers including Flex.
8) The Building Owner shall be responsible for the cost of investigation if any leak is determined not to be covered by this warranty.
9) Flex's sole obligation under this warranty shall terminate immediately in the event of a material change in use or a significant change in the
use of the building itself.
10) This warranty is extended solely and exclusively to the Building Owner, named below, at the time the Flex material is installed. It does
not extend nor is it otherwise assignable or transferable to any other party unless approved in advance and in writing by Flex and the costs
to process the transfer and to inspect and repair the roof, if necessary, are paid for by the original Building Owner.
I I) FLEX PROVIDES NO WARRANTY THAT THE FLEX ROOFING SYSTEM IS MERCHANTABLE OR FIT FOR ANY PARTICULAR PURPOSE.
THIS AGREEMENT AND THE REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND GIVEN IN LIEU OF ALL WARRANTIES OR
AGREEMENTS (WHETHER WRITTEN, ORAL, IMPLIED OR STATUTORY). NO REPRESENTATIVE OF FLEX HAS THE AUTHORITY TO
MAKE ANY REPRESENTATIONS OR PROMISES EXCEPT AS STATED HEREIN.
Name of Building Tukwila Pool
Building Owner's Name City of Tukwila
Address of Building 4414 South 144th Street, Tukwila, WA 98168
Flex Authorized Applicator Bates Roofing LLC, Tacoma, WA 98409
Flex Roof System Type FB Elvaloy 60 Mil White Area Warranted (Sq. Ft.) 17,000
Date Effective From 10/16/2013 To 10/16/2033
Flex Membrane International Corp, 2670 Leiscz's Bridge Road, Suite 400, Leesport, PA 19533
Phone 610-916-9500 • Fax: 610-916-9501
FLEX MEMBRANE INTERNATIONAL ROOFING SYSTEMS
ROOF MAINTENANCE, CARE REQUIREMENTS & RECOMMENDATIONS
The Flex Engineered Roofing System that now covers your building is a state-of-the-art roofing system that requires very
little attention. You have chosen a roofing system that when properly installed on a well designed and functioning building
and when properly maintained, will provide years of service. Flex recommends to the building owner that they take the
following actions.
RECOMMENDATIONS
A. REGULAR MAINTENANCE:
(I)
The roof should be inspected at least twice yearly (in the Spring and Fall) and after any severe storms. Access to the
roof should only be permitted to responsible personnel and a log kept of all times and parties working on the roof.
Record maintenance procedures as they occur.
(2) All counterflashing metal work, equipment curb and supports, pitch pockets, caulking, grease guards, traps, secondary
sheets, walkpads and any other rooftop accessories functioning in conjunction with the membrane roofing system must
be kept properly maintained at all times. Have all drains and rainspouts cleaned on a regular basis provide for proper
water runoff.
(3)
Materials should not be stored on the roof, and the building owner should remove broken bottles, metal, etc., and report
all damage and vandalism to Flex Membrane International Corp. Do not permit smoking on the roof.
(4) Regular cleaning and maintenance must be done in areas where contaminants potentially harmful to the roof system
may accumulate. Contact the Flex Technical Department on additional preventative maintenance as exposure to certain
chemicals could void the warranty.
(5) The Flex Roofing System is designed to be a waterproofing membrane. Protective walkways must be provided if there
is to be regular foot traffic on the roof for maintenance of equipment or any other reason.
B. IN THE EVENT THAT YOU HAVE A LEAK:
(I) Determine the cause of the leak (it may be the result of a clogged drain, broken pipes, loose counterflashing, broken
skylights, open grills or vents, damages or vandalism). Failure to determine the cause may result in a service charge
fee.
(2) Call the roofing contractor who installed the roof and send written notification to Flex Membrane International Corp.
within 30 days of discovery, per the terms of your warranty.
Note conditions resulting in leakage. Heavy or light rain, wind direction, temperature and time of day that the leak
occurs are all important clues to tracing roof leaks. Note whether the leak stops shortly after each rain or continues to
drip until the roof is dry. By being prepared with the facts, the diagnosis and repair of the leak can proceed more
rapidly.
(3)
(4) If necessary, make temporary repairs as required.
(5) Permanent repairs to the roofing system must be made by an approved Flex contractor with Flex products.
NOTE
A. It is the Owner's responsibility to provide easy access to the roofing membrane surface by removing or
moving rooftop equipment, pavers, severely ponded water, snow or any materials that prevent complete
investigation and repair.
B. Flex Membrane International Corp. supports and recommends following the guidelines for good roofing
practices found in the Single Ply Roofing Institute (SPRI) Manual of Roof Inspection, Maintenance and
Emergency Repair for Existing Single -Ply Roofing Systems and National Roofing Contractors Association
(NRCA) Roofing and Waterproofing Manual.
FL E C PY
Perm* No. biosmoot?
f#._ approval is subject to errors and omissions.
t,o :-•.,,f-ruction documents does not autherize
ti `..dopted code or ordinance. Rece;pt
Leotoveci Flo Copy and conditions is adtnowledged:
By VAY\ADA1—
mite: `t/ I 2113
City Of ltikwila
BUILDING DIVISION
T --- REVISIONS
&l
No enges shall be made to the scope
cf r,orif, without prior approval of
Tukwila Building Division.
1 Nr)177.: f'' 3VCrIS dl require a new plan submittal
i cal may include additional plan review fees.
SEPARATE PERMIT
RIQUIRED FOR:
teDleChanical
etlectrical
erhumbing
Giotas Piping
City of Tukwila
EtADiNG DIVISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 2 4 2013
City of Tukwila
BUILDING DIVISION
iMAP Tukwila Pool - Roofing Project
COMMENTS: 4414 S 144th Street, Tukwila WA 98168
Rick Still, 206-767-2344
The information included on this map has been compiled by King County staff from a variety of sources and is subject to change without notice. King County makes no representations or
warranties, express or implied, as to accuracy, completeness, timeliness, or rights to the use of such information. This document is not intended for use as a survey product. King County
shall not be liable for any general, special, indirect, incidental, or consequential damages including, but not limited to, lost revenues or lost profits resulting from the use or misuse of the
information contained on this map. Any sale of this map or information on this map is prohibited except by written permission of King County.
Date: 11/6/2012 Source: King County iMAP - Property Information (http://www.metrokc.gov/GIS!IMAP)
La King County
FILE COPY
Tukwila Pool Roof
Technical Specifications
Division -7 - Thermal and Moisture Protection
Section 07540 - Thermoplastic Membrane Roofing (Elvaloy®)
Fleece Back Membrane Adhered over Existing Roof Cover
PART 1 GENERAL
1.01 STIPULATIONS
A. The "General Conditions", "Special Requirements" and "General Requirements" are
incorporated into this section by reference.
B. This specification is to be applied, without variation, to only those building roofs having
deck structures capable of supporting the roof system in accordance with the applicable
loading requirements of the jurisdictional Building Code.
1.02 SYSTEM DESCRIPTION
- - --A.--Performance-Requirements: Furnish all -labor, materials; equipment -and supervision- to -
complete the roofing work on the roof areas at the above mentioned facility as shown and
specified herein. The installation shall comply with the terms and conditions of these
specifications and the membrane manufacturer's written installation instructions for a
roof system warranty.
B. Type of Roof System: Provide and install an Adhered, Fleece -Back, Thermoplastic and
CRRC approved roofing membrane to an existing roof cover.
C. Roof Membrane: Thermoplastic, Polyester Reinforced, Fleece -Back Elvaloy® Roofing
Membrane as manufactured and supplied by:
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 2 4 2013
City of Tukwila
BUILDING DIVISION
Or any equal product produced by manufacturer requesting substitution. (Private labeling
not acceptable)
Flex Membrane International, Inc.
2670 Leiscz's Bridge Road, Suite 400
Leesport, PA 19533
Phone: (800) 969-0108
Fax: (610) 916-9501
www.flexroofingsystems.com
RECEIVED
t;9TV OF TUKWILA
I JAN ',15 20131
o Rh.OT CENTER
TUKWILA POOL
ROOF PROJECT
Project No. TUKPOOL 2012-02
November 5, 2012
1.03 RELATED WORK
A. Related Sections: Section(s) related to this section include:
1. Section 072000 Insulation
2. Section 076000 Metal Work
3. Section 077000 Accessories
4. Section 154300 Plumbing
5. Section 061000 Rough Carpentry
1.04 REFERENCES
A. Factory Mutual (FM Global) – Approval Guide.
1. Factory Mutual Standard 4470 – Approval Standard for Class 1 Roof Covers.
B. Underwriters Laboratories (UL) – Roofing Systems and Materials Guide (TGFU R1306).
C. American Society for Testing and Materials (ASTM) – Annual Book of ASTM Standards
1.– --ASTM - tan ar Specification or -Faced Rigid Cellular Polyisocyanurate
Thermal Insulation Board.
2. ASTM C208 – Standard Specification for Cellulosic Fiber Insulating Board.
3. ASTM D6506 – Standard Specification for Asphalt Protection Board.
4. ASTM D41 – Standard Specification for Asphalt used in Roofing.
5. ASTM D1079 – Standard Terminology Relating to Roofing, Waterproofing and
Bituminous Material.
6. ASTM D4263 – Standard Test Method for Indicating Moisture in Concrete : • '
7. ASTM D4434 – Standard Specification for Poly (vinyl chloride) Sheet Roofing.
D. Sheet Metal and Air Conditioning Contractors National Association, Inc. (SMACNA)
Architectural Sheet.
E. National Roofing Contractors Association (NRCA).
F. American Society of Civil Engineers (ASCE).
TUKWILA POOL
R PROJECT
PrjeciNOWTUKPOOLqq
2012-02
, v42.
No�rember 2012
0 6
1. ASCE 7 Minimum Design of Loads for Buildings and Other Structures.
1.05 DEFINITIONS
A. Roofing Terminology: Refer to ASTM D 1079 and the glossary of the National Roofing
Contractors Association (NRCA) Roofing and Waterproofing Manual for definitions of
roofing terms related to this section.
1.06 SUMITTALS
A. General: Submit listed submittals in accordance with General Requirements Subgroup,
Division 1, Submittal Procedures Section.
B Submit product data, including manufacturer's technical data sheet for all specified
products.
C. Shop Drawings: Submit shop drawings showing roof configuration, sheet layout and
details of application.
D. Samples: Submit selection and verification samples of manufacturer's product line.
E. Quality Assurance Submittals: Submit the following:
1. Test Reports: Certified test reports showing compliance with specified
performance characteristics and physical properties.
2. Certificates: Product certificates signed by manufacturer certifying materials
comply with specified performance characteristics and criteria and physical
requirements.
3. Manufacturer's Instructions: Manufacturer's Installation Instructions
4. Manufacturer's Field Reports: Manufacturer's field reports specified herein.
F. Closeout Submittals: Submit the following:
1. Maintenance Data: Maintenance data for installed products. Include methods for
maintaining and repairing installed products -and precautions against cleaning
materials and methods detrimental to finishes and performance.
2. Warranty: Warranty documents specified herein.
1.07 QUALITY ASSURANCE
TUKWILA POOL
ROOF PROJECT
Project No. TUKPOOL 2012-02
November 5, 2012
A. Installer Qualifications: Installer shall have a minimum of five (5) years experience in the
application of thermoplastic membrane and shall be currently certified by the
manufacturer of the membrane system.
B. Manufacturer Qualifications: Membrane manufacturer shall have a minimum of fifteen
(15) years experience in the production of thermoplastic Elvaloy® scrim -reinforced
membrane, having properties as further defined in these specifications.
C. Membrane Qualifications: Membrane shall be factory certified, first run material,
seconds will not be permitted. Material and packaging to bear the FM label on the roll.
D. Regulatory Requirements:
1. Approvals: Provide Thermoplastic Fleece -Backed Elvaloy® Roofing Membrane
with the following approvals:
Underwriters Laboratories Class A Rating
Factory Mutual 1-90
ICC -ES
HUD
Energy Star® Partner
CRRC Approval
2. Work shall be performed in a safe, professional manner, conforming to federal,
state add oca codes:
E. Source Quality: Obtain thermoplastic Elvaloy® membrane and components from a single
manufacturer.
1.08 PRE -INSTALLATION CONFERENCE
A. Prior to scheduled commencement of the roofing installation and associated work
conduct a meeting at the project site with the Installer, Architect, Building Owner,
Manufacturer's Representative and any other persons directly involved with the
performance of the work.
The installer shall record conference discussions to include decisions, agreements and
open issues and furnish copies of recorded discussions to each attending party. The
primary purpose of the meeting is to review foreseeable methods and procedures related
to roofing work.
1.09 DELIVERY, STORAGE AND HANDLING
A. General: Comply with Division 1 Product Requirements Sections.
B. Ordering: Comply with manufacturer's ordering instructions and lead time requirements
to avoid construction delays.
TUKWILA POOL
ROOF PROJECT
Project No. TUKPOOL 2012-02
November 5, 2012
C. Delivery: Deliver materials in manufacturer's original, unopened, undamaged containers
with identification labels intact and in sufficient quality to allow for continuity of work.
D. Storage and Protection: Store materials protected from exposure to harmful weather
conditions and at temperature and humidity conditions recommended by manufacturer.
Leave product wrapped and protected in original packing with identification labels, until
ready for use on the job. Store in a clean, dry, well ventilated area protected from
weather and other trades. All rolls of membranes shall be stored, lying down, elevated
above the roof deck and completely protected from moisture with tarpaulins. Insulation
shall be stored on pallets, fully protected from moisture with tarpaulins. Adhesives shall
be safely stored, at temperatures above 45°F. Flammable materials shall be stored in a
cool dry area away from sparks and open flames. Manufacturer's Material Safety Data
Sheets are to be available at the project and all precautions and safety instructions
followed.
E. Damages: Any material having been determined by the owner/owner's representative to
be damaged, shall be immediately removed from the construction site and replaced at no
cost to the owner.
1.10 PROJECT CONDITIONS
A. Weather
1. Proceed with theroof installation only when existing and forecasted weather
conditions permit.
2. Ambient Temperatures shall be above 35°F when applying adhesives.
1.11 WARRANTY
A. Project Warranty: Refer to conditions of the contract for the project warranty provisions.
B. Manufacturer's Warranty: Submit for the Owner's acceptance, manufacturer's standard
warranty document executed by authorized company official. Manufacturer's warranty
is in addition to, and not a limitation of, other rights Owner's many have under Contract
Documents.
1. The Manufacturer's Technical Service Representative shall inspect the completed
Roof System, and upon acceptance, the Manufacturer shall issue the specified
NDL 20 year warranty, subject to the terms and conditions of the sample warranty
and the contract documents commencing on Date of Substantial Completion.
C. Installation Warranty: The roofing contractor shall be responsible for all leak
investigations and any necessary repairs to the roof system as provided for by the
Membrane Manufacturer's Request for Guarantee document.
TUKWILA POOL
ROOF PROJECT
Project No. TUKPOOL 2012-02
November 5, 2012
PART '2 - PRODUCTS
2.01 THERMOPLASTIC REINFORCED ELVALOY® ROOFING MEMBRANE
A. Manufacturer:
Flex Membrane International, Inc.
2670 Leiscz's Bridge Road, Suite 400
Leesport, PA 19533
Phone: (800) 969-0108
Fax: (610) 916-9501
www.flexroofingsystems.com
B. Membrane: Type:
Thickness:
Reinforcement:
Color:
Width:
C.
Flex FB Elvaloy®
0.060", nominal with minimum 10 foot wide sheet
Bonded polyester
White, Light Gray, Tan
Manufacturer's standard maximum for specified
application
Physical Properties: Membrane shall have the following minimum physical property
values:
Property
Color
Thickness
Tensile Strength
-Breaking Strength -
Tear Strength
Tear Strength at break
Elongation
Seam Strength
Puncture Resistance
Impact Resistance
Shore A Hardness
Heat Aging
Cold Resistance
Vapor Permeability
WT. Change After
Immersions
Seam Strength
Dimensional
Stability
Accel. Weathering
(xenon arc)
Solar Reflectivity
Emissivity
Solar Reflective Index
TUKWILA POOL
ROOF PROJECT
Project No. TUKPOOL 2012-02
November 5, 2012
Test Method
ASTM D751
ASTM D638
ASTM -D751- - -
ASTM D751
ASTM D751
ASTM D751
ASTM D751
FS 101C, Method 2031
SBCCI SSTD 12-99
ASTM D2240
ASTM D3045
ASTM D2136
ASTM E96
ASTM D570
ASTM D751
ASTM D1204
ASTM 2565
ASTM E903
ASTM E903
ASTM E1980
Specification
White, Light Gray, Tan
.060"
1710 x 1830 psi
-- 390-k356 _ -
98 x 85 lbf
439 x 389 lbf
>100%
359 lbf
440 lbs
Pass
83
90%
-40°F
3.5 g/m2/day
1.5%max
80%
0.5%
10M hrs. (no change)
.811 (white)
.919 (white)
109 (white)
2.02 PRODUCT SUBSTITUTIONS
A. Substitutions: Requests for submissions will be considered in accordance with the
provisions of Section 01600.
2.03 RELATED MATERIALS
A. Accessories Materials
1. Adhesives: Supplied by the same manufacturer as the membrane and formulated
for use with thermoplastic membrane. Each container shall have the shelf life
date marked on a label.
a. Flex Deck Low Rise Adhesive: moisture cure one part urethane adhesive.
Bonds Fleece back membrane to suitable substrates. Applied in 3/8" to
1/2" beads spaced to meet wind uplift requirements.
2. Flashing provided by the membrane manufacturer.
a. Reinforced Membrane: Flex MF/R, same material, color and thickness as
roof membrane for all curbs, walls and penetrations.
b. Non reinforced Membrane: Flex MF: multi angled intersections, sealant
pockets and other conditions that would be impractical for reinforced
_ membrane application:
c. Membrane coated metal: Flexclad Metal.
d. Flex pipe boot: prefabricated pipe moldings.
e. Inside/Outside corners.
2. Miscellaneous Materials: Multi purpose caulking, water cut off mastic and like
materials compatible with all components of the roofing system to be supplied by
the membrane manufacturer.
a. Flex Pourable Sealer used to top off pitch pans.
3. Mechanical Fasteners and Plates: Use Factory Mutual approved corrosion
resistant membrane fasteners and plates provided and approved by Flex for the
membrane application and substrate condition as established by pull out tests.
4. Traffic Pads: Flex Walkway Pad: 36 inch wide x 60 feet long x .080 inch thick
thermoplastic material provided by the membrane manufacturer.
B. RELATED MATERIALS: Refer to other sections for related materials as follows:
TUKWILA POOL
ROOF PROJECT
Project No. TUKPOOL 2012-02
November 5, 2012
c
1. Wood Nailers: No. 2 or better southern yellow pine, kiln dried, rot and insect
resistant. Installed at edges, roof penetrations and other areas where secure
mechanical attachment is required. Attach to structural deck in a Factory Mutual
approved manner.
2. Insulation: Used to replace any wet insulation board manufactured for use in roof
system construction.
a. Flex ISO insulation.
b. Factory Mutual approved rigid insulation meeting Class 1-90, for fire and
wind.
c. Underwriters Laboratories Class A rating.
d. Compressive Strength minimum 20 PSI.
PART 3 — EXECUTION
3.01 MANUFACTURER'S INSTRUCTIONS
A. Compliance: Comply with manufacturer's product data, including product technical
bulletins, product catalog instructions and product carton instructions for installation.
3.02 EXAMINATION
A. Site verification of conditions: Verify substrate conditions, which have been previously
installed under other sections, are acceptable for product installation in accordance with
manufacturer's instructions. Verify that all roof openings or penetrations through the
roof are solidly set and that required tapered areas have been installed.
B. Corrections: Do not proceed with installation of roofing material until all defects and
preparation work has been corrected and is complete. Installation of the roofing material
constitutes that the roofing contractor has inspected and found the deck suitable for
installation of the Flex Roof System.
3.03 INSTALLATION
A. Existing Roof Cover
1. Have a professional infrared roof survey performed to find any wet insulation or
defects.
2. Any areas with wet insulation are to be removed. Replace any wet insulation with
an insulation board of similar thickness.
TUKWILA POOL
ROOF PROJECT
Project No. TUKPOOL 2012-02
November 5, 2012
3. Damaged areas to be repaired by installing a minimum of 1 ply of SBS modified
membrane overlapping the existing covering by a minimum of 12" prior to
installing the Flex roof membrane.
4. If required deck must be primed 24 hours prior to roof system insulation with an
ASTM D-41 compliant cut back asphalt primer. Apply primer in accordance with
the primer manufacturer's current application instructions.
5. Finished substrate shall be properly cured, dry and ready to receive Adhesive.
6. Substrate shall be smooth surfaced. Clean and free of moisture or debris.
E. Flex FB Installation
1. Fully adhere membrane to acceptable substrate with Flex Substrate Adhesive
applied at the rate specified by the manufacturer.
2. The roof surface must be clean, dry and free of foreign material. It is required that
the ambient air temperature is above 35°F for the use of cold adhesives.
3. Position sheets as indicated on approved shop drawings. Measure and chalk lines
on the substrate to establish proper alignment of the sheet.
4.- Place the rollhe line and unroll the Flex FB its entire length and allow the
membrane to relax. The relaxation time required is dependent on the ambient air
temperature.
5. Fold one end of the Flex FB sheet on top of itself until both ends meet. Apply the
bonding material (Flex Substrate Adhesive or hot steep asphalt) to the prepared
roof surface. The sheet can then be pulled and laid into the bonding material
using care not to create any wrinkles.
6. Carefully push and broom into place from fold line to overlap, avoiding wrinkles
and air pockets. Roll with a heavy roll (minimum 200 lbs.) to insure proper
adhesion.
7. Repeat procedure for other half of the sheet.
8. Lap seams shall be done by lapping the 3" selvedge edge over the non selvedge
edge of the previous roll. Do not allow adhesives or other contaminants to the
lapped seam. The selvedge edge seam will be completed by the hot air welding
method. Seams are to be completed each day during construction.
9. Roll ends are butted together and capped with a 6" wide Flex Trim Strip. The
trim strip is centered over the end joint and hot air welded into place.
TUKWILA POOL
ROOF PROJECT
Project No. TUKPOOL 2012-02
November 5, 2012
10. All seams must be checked with a needle probe and any voids repaired with the
heat gun the same day they are made.
F. Seam Welding
1. All Seams must be clean and dry prior to proceeding with the hot air welding
procedure. The seams may be cleaned using a clean cotton rag dampened with a
mild solvent such as acetone or MEK. Allow the seams to thoroughly dry after
cleaning.
2. All seams greater than 10' in length should be welded with an automatic type
welding unit. Hand held welders are used for the remaining seams and all detail
welding.
3. A properly welded seam should be a solid weld approximately 1 1/2" wide.
G. Inspections
1. All seams are to be completed by the hot air welding method each day as the
installation progresses.
2. The roofing contractor is to designate a responsible person to inspect the
completed installation each day as the installation progresses. The inspection is to
include hand probing of all welded seams.
3. Any defects found during these inspections should be immediately corrected.
3.04 FLASHING
A. Flashing all penetrations, walls, curbs, expansion joints, drains as shown on details and
approved shop drawings with Flex Flashing Membrane.
1. Use Manufacturer's supplied flashing accessories or components such as sealant
pockets and prefabricated vent / pipe flashing.
2. Mechanically fasten flashing at terminations according to approved details.
a. Fastening Flashing Membrane through counter -flashing metal is not
acceptable.
3. Flashing Membranes are installed adhered to the approved substrate Flex Flashing
Adhesive.
Flashing Membrane is to be installed flat and wrinkle free. Flashings should be
rubbed or rolled onto the substrate for proper adhesion.
TUKWILA POOL
ROOF PROJECT
Project No. TUKPOOL 2012-02
November 5, 2012
3.05 WOOD NAILERS
A. Locate and install as shown on details: along gravel stops and drip edges and other areas
as required by membrane manufacturer.
B. Anchor nailer to structural deck with manufacturer's approved fasteners, spaced
approximately for the specified installation; minimum withdrawal resistance: one
hundred pounds.
3.06 DAILY SEAL
A. At the end of each working day or at the first sign of inclement weather, install
temporary, 100% watertight seal where the completed new roofing adjoins the uncovered
deck or existing roof surface.
B. The roofing contractor shall be responsible for creating and maintaining the temporary
seal in sucha manner as to prevent moisture from entering into the new and or the existing
roof system.
C. Material for construction of the temporary seal to be from the Membrane Manufacturer's
List of approved products 'and accessories.
D. Prior to commencing additional roof installation, cut out and remove all contaminated
membrane, insulation and temporary sealant and properly dispose in accordance with the
Contract Documents.
3.07 FIELD QUALITY REQUIREMENTS
A. Manufacturer's Field Services: Upon owner's request, provide manufacturer's field
service consisting of product use recommendations and periodic site visits for inspection
of product installation in accordance with manufacturer's instructions.
1. Site Visits: Coordinate site visit schedule with manufacturer's technical service
department.
2. Final inspection and acceptance of the installation by the manufacturer's technical
representative is required before a warranty can be issued
B. Roof Protection
1. Protect all partially and fully completed roofing work from other trades until
completion.
2. Whenever possible stage materials in such a manner that foot traffic is minimized
over the completed roof sections.
TUKWILA POOL
ROOF PROJECT
Project No. TUKPOOL 2012-02
November 5, 2012
3. Temporary platforms and walkways shall be installed in order to protect all
completed roof sections from traffic and material handling during the application
process.
3.08 CLEANING
A. All work areas are to be kept clean, clear and free of debris at all times.
B. Do not allow trash, waste or debris to collect on the roof. These items shall be removed
from the roof on a daily basis.
C. Dispose of or recycle all trash and excess material in a manner conforming to current
EPA regulations and local laws.
D. Upon completion clean the installed products in accordance with the manufacturer's
instructions prior to owner's acceptance.
E. Clean and unclog all drains, scuppers, leaders and downspouts.
F. Clean and restore all damaged surfaces to their original condition.
TUKWILA POOL
ROOF PROJECT
Project No. TUKPOOL 2012-02
November 5, 2012
12/2/2013
City of Tukwila
Department of Community Development
ROBERT EATON
12424 42 AV S TUKWILA, WA
pQ 4Q T\ CA 08168_
t:Aw,..w�: e.e:ee
RE: Permit No. D13-019
CITY OF TUKWILA - POOL
4414 S 144 ST
Dear Permit Holder:
Jim Haggerton, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of
such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun
for a period of 180 days. Your permit will expire on 1/7/2014.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 1/7/2014, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Marshal
echnician
File No: 113-019
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
MPERMIT COORD COFO
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: D13-019 DATE: 01/15/12
PROJECT NAME: CITY OF TUKWILA POOL (REROOF)
SITE ADDRESS: 4414 S 144 ST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
AtAK (42'm-15
Building Division imp
Public Works
A -w` 1//1 -T-1 3
Fire Prevention
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete ❑
DUE DATE: 01/17/13
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials:
TUESITHURS ROUTING:
Please Route
REVIEWER'S IN TIALS: DATE:
Structural Review Required ❑ No further Review Required ❑
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 02/14/13
Not Approved (attach comments) ❑
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Contractors or Tradespeoplinter Friendly Page
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name BATES ROOFING LLC UBI No. 602605377
Phone 2534730675 Status Active
Address Po Box 9416 License No. BATESRL945JO
Suite/Apt. License Type Construction Contractor
City Tacoma Effective Date 4/20/2006
State WA Expiration Date 4/20/2014
Zip 98409 Suspend Date
County Pierce Specialty 1 General
Business Type Limited Liability Company Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
BATESC*142K7
BATES
CONSTRUCTION
Construction
Contractor
General
Unused
5/27/1986
5/1/2002
Archived
ALANRC'167KB
ALAN ROOFING Et
CONSTRUCTION
Construction
Contractor
General
Unused
5/2/1984
5/1/1986
Archived
BATESRI984J4
BATES ROOFING INC
Construction
Contractor
General
Unused
4/24/2002
4/24/2006
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
BATE, THOMAS A
Partner/Member
04/20/2006
Amount
BATE, KATHLEEN A
Partner/Member
04/20/2006
FMWA002233
Bond Information
Bond Company Name
CBIC
Bond
1
Page 1 of 2
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
SE8468
04/17/2006
Until Cancelled.
$12,000.00
04/20/2006
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
7
First Mercury
Ins Co
FMWA002233
04/17/2011
04/17/2013
$1,000,000.0004/02/2012
6
First Mercury
Ins Co
FMWA0013061
04/17/2011
04/17/2012
$1,000,000.0004/15/2011
5
FIRST MERCURY
INS CO
FMWA001306
04/17/2010
04/17/2011
$1,000,000.00
04/14/2010
4
FIRST MERCURY
INS CO
FMWA0001283
04/17/2010
04/17/2011
$1,000,000.0004/13/2010
3
FIRST MERCURY
INS CO
FMWA0001282
04/17/2008
04/17/2010
$1,000,000.0004/17/2009
2
FIRST MERCURY
INS CO
FMFL002685
04/17/2007
04/17/2009
$1,000,000.00
04/16/2008
1
FIRST MERCURY
INS CO
FMFL004653
04/17/2006
04/17/2007
$1,000,000.00
04/20/2006
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
httnc•//fnrtrecc wa unv/lni/hhin/Print_a:snx
04/12/2013