Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D13-0341 - VISION PLUS - TENANT IMPROVEMENT
VISION PLUS 381 STRANDER BL D13-0341 Parcel No: Address: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2623049064 381 STRANDER BLVD Project Name: VISION PLUS DEVELOPMENT PERMIT Permit Number: Issue Date: Permit Expires On: D13-0341 12/3/2013 6/1/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: REGENCY CENTERS LP PO BOX 790830, SAN ANTONIO, WA, 78279 WEIQUN GUO Phone: (206) 310-4524 381 STRANDER BL , TUKWILA, WA, 98188 WOODMAN CONSTRUCTION INC Phone: (425) 454-3621 3 Lake Bellevue Dr 201, BELLEVUE, WA, 98005 WOODMCI16706 Expiration Date: 1/5/2015 TENANT FINANCED DESCRIPTION OF WORK: NEW TENANT: TENANT IMPROVEMENT TO CREATE THREE SEPARATE EXAM ROOMS IN THE SPACE Project Valuation: $90,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: Fees Collected: $2,326.46 Type of Construction: Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature:,' ' /t.itiC� LSC/ • Date: /a/3 1 hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: WtavN cryo Date: /0/3 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). • • 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 13: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 23: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 24: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 25: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) • • 26: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2328. 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 28: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 29: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 32: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0409 FRAMING 0406 SUSPENDED CEILING 2 1700 BUILDING FINAL** • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Building Permit No. 14 Project No. 13 r 1L Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 381 Strander Blvd, Tukwila, WA 98188 Tenant Name: Vision Plus King Co Assessor's Tax No.: ? 6 2 3o4 [ O Suite Number: Floor: 1 New Tenant: m Yes ❑ ..No PROPERTY OWNER ' Name: Regency Centers Corporation Address: 5335 SW Meadows Road, Suite 295 City: Lake Oswego State: OR Zip: 97035 CONTACT PERSON — person receiving all project communication Name: Weiqun Guo Address: 381 Strander Blvd City: Tukwila State: WA Zip: 98188 Phone: (206) 310-4524 Fax: (253) 872-1021 Email: weiqung@hotmail.com GENERAL CONTRACTOR INFORMATION T Company Name: WOOd vii 041Con ttr tc Veil /Lc Address: 3 Lake agt1&vktR PY7V'2 44,20 City: Be,U.eryLitt State: WA Zip:98'005 Phone: (¢25)454 3621 Fax: (4.25)45469/g Contr Reg No.: WOOP/V)C 1 16 ?06, Exp Date: t /540, 5 Tukwila Business License No.: VW- 6 ons' City: Ibk45- 011CV1 I H:\Applications\Forms-Applications On Line12011 Applications\Permit Application Revised - 8-9-I1.docx Revised: August 2911 bh ARCHITECT OF RECORD Name: Company Name: CHC Architects Company Name: NA Architect Name: Chaohua Chang Address: 526 14th Ave W City: City: Kirkland State: WA Zip: 98033 Phone: (425) 285-9855 Fax: (425) 285-9911 Email: cchang03@yahoo.com State: ENGINEER OF RECORD Name: -7i_. -1-ik aAt'C( Company Name: NA Address: Engineer Name: City: State: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: -7i_. -1-ik aAt'C( Address: City: State: Zip: Page 1 of 4 • 1 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 90,000 Describe the scope of work (please provide detailed information): 3 Qixc re-s-wvs „11 Will there be new rack storage? ❑ Yes Existing Building Valuation: $ E.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 'For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No [f"yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Eg Sprinklers ® Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes jo No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:tApplications\For ns -Applications On Line12011 Applications\Permil Application Revised - 8-9-11.docs Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor (078 sf f 07 8 rd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 'For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No [f"yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Eg Sprinklers ® Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes jo No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:tApplications\For ns -Applications On Line12011 Applications\Permil Application Revised - 8-9-11.docs Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: WEI Q UN 6 -UO Mailing Address: 3 g ( S'tr/2444&. 13144 Date: 11/4 /)o/3 Day Telephone: c200 " 3/0— 4502 W1emV't L& City H:\Applications\Forne-Applications On Line\2011 Applications\Permit Application Revised - 8-9-I l.docx Revised: August 2011 bh WA State Zip Page 4 of 4 $ r • • PUBLIC WORKS PERMIT INFORMATION - 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate Septic System: 0 On-site Septic System — For o site septic system, provide 2 copies of a current s ic design approved by King County Health Department. 0 .. Highline ❑ ...Valley View ❑ .. Renton ❑...Sewer Availability Provided Renton ❑ .. Seattle Submitted with Application (mark es which apply): 22" x 34") inage) Easement(s) ❑ ...Civil Plans (Maximum Paper Size ❑ ...Technical Information Report (Storm ❑ ...Bond 0 .. Insurance Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hou ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut 0 ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protectio Irrigation Domestic ''v ater ❑ .. r bandon Septic T Curb Cut .. Pavement Cut .. Looped Fire Line 0 ...Permanent Water Meter Size ❑ ...Temporary Water Meter Si ❑ ...Water Only Meter Size. ❑ ...Sewer Main Extension 39 Public 0 0 ...Water Main Extensio Public 0 WO # WO # WO # ❑...Deduct ater Meter Size Private 0 Private 0 ❑.. . echnical echnical Report aintenance Agreement(s) ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) 0 .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use—Potential Disturbance ❑ .. Work in Flood Zone .. Storm Drainage ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation 0 .. Utility Undergrounding f! FINANCE INFORM ON Fire Line Size at Prn,certy Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer 0 ...Sewage Treatment Month! Sery -- Billin_ to: Name: Day Telephone: Mailing , ddress: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applicatio a\Forms-Applications On Line\20I 1 ApplicationsiPermit Application Revised - 8-9-11.docc Revised: August 2011 bh Page 3 of 4 Cash, Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,411.75 D13-0341 Address: 381 STRANDER BLVD Apn: 2623049064 $1,411:75 DEVELOPMENT PERMIT FEE WASHINGTON STATE SURCHARGE TOTAL FEES PAID BY RECEIPT: R241 R000.322.100.00.00 B640.237.114 $1,411.75 $1,407.25 $4.50 $1,411.75 Date Paid: Tuesday, December 03, 2013 Paid By: GUO EYECARE Pay Method: CREDIT CARD 713081 Printed: Tuesday, December 03, 2013 3:18 PM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $914.71 D13-0341 Address: 381 STRANDER BLVD Apn: 2623049064 $914:71 DEVELOPMENT $914.71 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R12 000.345.830.00.00 $914.71 $914.71 Date Paid: Tuesday, November 05, 2013 Paid By: WEIQUN GUO, GUO EYECARE Pay Method: CREDIT CARD 315065 Printed: Wednesday, November 06, 2013 11:29 1 of 1 AM I?WSYSTEMS • w City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 2623049064 Address: 339 STRANDER BL TUKW Suite No: Applicant: VISION PLUS RECEIPT Permit Number: D13-341 Status: PENDING Applied Date: 11/05/2013 Issue Date: Receipt No.: R13-03057 Initials: User ID: JEM 1165 Payment Amount: $914.71 Payment Date: 11/05/2013 11:56 AM Balance: $1,411.75 Payee: WEIQUN GUO, GUO EYECARE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 315065 ACCOUNT ITEM LIST: 914.71 Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 914.71 Total: $914.71 a.,... Rcroin}_nR Printed• 11-05-9013 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Di -3-63'41 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Projet: Vt5t( \'L11 ' Type of Inspection: 1n)�1 t Address: /� n C Date Called: Special Instructions: Date Wanted: (m9, I.--- -- I Ct p.m. Requester: Phone No: `1225 - LIZ%j — 0 N S Approved per applicable codes. Corrections required prior to approval. COMMENTS: p,j-ruCii--(i,t9MD16710 Inspect Date: REINSPECTION FEE REQUIRED.Friar to next inspection. fee must be paid at 6300 Southcenter Blvd.. Shite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD , Retain a copy with permit. 3 -0341 PERMIT NO. -1(^1 CITY OF.TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 9818.8 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: e, t •kl; s , vi/ �Pl J5 Typ of Inspection: LISen ` f ! ,� Address: 3g( SIT(A/uo-ik Date Called. Special Instructions: Date Wanted:. rr�� I Z '2.-5 �� �,.m� �a p.m. Requester: Phone No: Approved per applicable codes.' Corrections required prior to approval. COMMENTS: Date: r3 REINSPECTION FEE RE IRED. PYior to next inspection, fee must be paid at 6300 Southcen r Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 b) 3 v3I Project: . 0S'6N) PHIS Type ofInspection: r/2/MI (,..i(i Address: 3A1 • )24,Q6, - P Date Called: Special Instructions: Date Wantec): a.m: Requester: Phone No: Approved per applicable codes.. ElCorrections required prior to approval. COMMENTS: Date: 1 kINS/ CTION FEE REQUIRIJD. Priortonext inspection, fee must be paib-at"6300 Southcenter Blvd., Suite 100. Call to schedule reinspection: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1-03 X11 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (20.6) 431-2451 Project: VISION) LTIS Type of Inspection: 1. RAW 1Q(® Address: 3 6.1 S QA►J {Z..: •. Date Called: . Special Instructions:.. Date Wanted:. 1Z i5G3 a. p.m. Requester: Phone No: 1I2S I-614 3 ;' Z Approved per applicable codes. COMMENTS: Corrections required prior to approval. E IAC -TR is A• L- as tl l— ..q INSPECTION FEE RE aid at 6300 Southcente °12-- l3 1I UIRED. Pri6r.-to next inspection. fee must be Blvd., Suite 100.Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PL3- 03(1/___ / 3 - r- / 3 - 5— c9 98 '-/3-5—a98 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: VI .5-io rt1 P(It 5 Sprinklers: Fire Alarm: Tye of Inspection: -' S(3 -C.)ie. V, , Address: 3 2 i 5-6t4ivde Suite #: 13 1___, Contact Person: Special Instructions: Phone No.: ?Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: , Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector S ,„.2-__ Date: ve//y Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: - U12/ '61+0 P Fire Alarm: Type of Inspection: 5 P c®IJ Address: 3siv_eAcw_j Suite #: Ler 1 Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Ori-- Cevo_y--" Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: RA & 5oi-- Date: / Z/c 22// 3 Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Joanna Spencer From: Todd Reedy Sent: Thursday, November 14, 2013 7:17 AM To: Joanna Spencer Subject: RE: Vision 8weT1 @ 381 Strander Blvd D13-0341 P L.% s Hi Joanna, 381 Strander (Southcenter Plaza) is current on backflow preventer installation and testing. Have a great day, Todd From: Joanna Spencer Sent: Tuesday, November 12, 2013 5:13 PM To: Todd Reedy Cc: David McPherson Subject: Vision One 11 @ 381 Strander Blvd D13-0341 Hi Todd, Are their backflows current ? Thanks, Joanna Spencer Development Engineer Tukwila Public Works 6300 Southcenter Blvd., Suite 100 Phone: (206)431-2440 Fax: (206)431-3665 Joanna.Spencer@TukwilaWa.gov /www.TukwilaWa.gov The City of opportunity, the community of choice. 1 DI3O3' j PERMIT COORD COPY/iv PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-0341 DATE: 11/05/13 PROJECT NAME: VISION PLUS SITE ADDRESS: 381 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: �(.• ��3 Building Division L tt 1'5 Public Works 335 AY Fire Prevention Structural b1V1 (I� Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete M Incomplete DUE DATE: 11/07/13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 151/ REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 12/05/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: Contractors or Tradespeople Pier Friendly Page • General/Specialty Contractor A business registered as a construction contractor with Lal to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name WOODMAN CONSTRUCTION INC UBI No. 600529580 Phone 4254543621 Status Active Address 3 Lake Bellevue Dr 201 License No. WOODMCI16706 Suite/Apt. License Type Construction Contractor City Bellevue Effective Date 9/26/1984 State WA Zip 98005 County King Business Type Corporation Parent Company Expiration Date 1/5/2015 Suspend Date Specialty 1 General Specialty 2 Unused License Name Type- Specialty 1 Specialty 2 Effective Date Expiration Date Status WOODMAN, MARTHA C WWOODMC`172MLO CTION CONSTRUCTION Construction Contractor General Unused 7/13/1983 7/12/1984 Archived SONCOC*230CP SON CONSTRUCTION COMPANY Construction Contractor General Unused 2/17/1977 11/3/1983 Archived Business Owner Information Name Role Effective Date Expiration Date WOODMAN, PETER J President 01/01/1980 Amount WOODMAN, MARTHA C Vice President 01/01/1980 C4026964077 Bond Information Page 1 of 2 Bond 6 Bond Company Name LIBERTY MUTUAL INS CO Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 23005112 07/22/2001 Until Cancelled $12,000.00 12/31/2001 Assignment of Savings Information Savings 1 Assignment of Savings Account Number Effective Date PERSONAL CHECK #473 9/26/1984 Release Date Until Released Assignment Type Impaired Date Amount Received Date Bond 5/31/1991 $6,000.00 9/26/1984 Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 18 VALLEY FORGE INS CO C4026964077 02/05/2011 02/05/2014 $1,000,000.00 02/01/2013 17 AMERICAN ZURICH INS CO GL0399262106 02/05/2005 02/06/2011 $1,000,000.00 02/01/2010 Summons/Complaint Information Cause County Complaint Judgment Status Payment Paid By 10-2-36185-5SEA WOOD WORKIN INC InterPlead: No KING Date: 10/14/2010 Amount: $30,447.50 Bond(s): 23005112 Date: Amount: $0.00 Dismissed Date: Amount: Warrant Information No unsatisfied warrants on file within prior 6 year period httns://fortress.wa. 2ov/lni/bbip/Print.aspx 12/03/2013 RAIANCE grander Boulevard SITE PLAN PROJECT INFORMATION SCOPE OF WORK REMOVE (2) EXISTING WALLS, ADD PARTITION WALLS & SINKS WITH NEW ACOUSTICAL CEILING PROPERTY OWNER REGENCY CENTERS LP ZONING DISTRICT TUC SITE AREA 260,410 S.F. PARCEL NUMBER 2823049084 ADOPTED BUILDING CODE 2012 IBC PREVIOUS USE RESTAURANT PROPOSED USE RETAIL 1 CLINIC (OPTOMETRY) OCCUPANCY CLASSIFICATION GROUP B' BUILDING CONSTRUCTION TYPE V -B BUILDING YEAR BUILT 1990 GROSS BUILDING FLOOR AREA 31,600 S.F. T.I. FLOOR AREA 1,078 S.F. OCCUPANT LOAD 11 (1078 / 100) PLUMBING FDCTURE REQUIRED 1(1 IS PROVIDED) FIRE SPRINKLER SYSTEM YES LEGAL DESCRIPTION LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 91 -9 -SS RECORDING NO 9208281819 SAID SHORT PLAT DAF- POR OF SW 1/4 OF NE 1/4 - BEG SW COR OF NE 1/4 TH N 01-10-24 E 1293.57 FT TO S MGN OF STRANDER BLVD TH S 88-15-33 E 685 FT TO POB TH S 01-44.27 W 63 FT TAP OF TANGENT CURVE CONCAVE TO NE RAD OF 130 FT TH SELY ALG SD CURVE THRU ARC OF 34-27-01 ARC LENGTH OF 78.17 FT TH S 88.1533E 212.17 FT TH S 01.44-27 W 82 FT TH S 88-1533 E 9 FT TH S 01-44-27W 62 FTTH N 88.1533 W 133 FT TH S 01-44-27 W 150 FTTH N 88-1533 W482.33 FT TH S 48.2837 W 113.91 FT TH S 01-44-27 W 37.10 FT TH N 88.1533 W 120 FT TH S 01.44-27 W 80 FT TH N 88.1533 W 84.69 FT TO W LN OF SAID SW 1/4 TH S 01.10.24 W 687.83 FT TO SW CORNER OF NE 1/4 THS 88.0643 E 1309.38 FT TO W MGN OF ANDOVER PARK WEST TH N 01-03-25 E 1296.97 FT TO S MGN OF STRANDER BLVD TH N 88-1533 W 641.71 FT TO POB —AKA LOT 2 OF CITY OF TUKWILA LOT LN ADJ NO888-BTA RECORDING NO 8901240241— LESS PORTION FOR RNV TO CITY OF TUKWILA ABBREVIATIONS BLK'G CLLR CONT CS DBL DS EL EQ EXIST FTG FX HDR HDWD HGR BLOCKING CENTER LINE CLEAR CONTINUOUS CASEMENT WINDOW DOUBLE DOWNSPOUT ELEVATION EQUAL EXISTING FOOTING FIXED WINDOW HEADER HARDWOOD HANGER HORIZ MAX MFR MIN o/ o.C. SD SG SF SIM SLD TYP UNO V.T.O.S. wl HORIZONTAL MAXIMUM MANUFACTURER MINIMUM OVER ON CENTER SMOKE DETECTOR SAFETY GLASS SQUARE FEET SIMILAR SLIDING WINDOW TYPICAL UNLESS NOTED OTHERWISE VENT TO OUTSIDE WITH CONTRACTOR TO VERIFY ALL OF EXISTING CONDITIONS PRIOR TO CONSTRUCTION. REPORT TO ARCHITECT FOR ANY DISCREPENCIES FOUND. MINIMUM NAILING SHALL COMPLY WITH TABLE 2304.9.1 OF THE 2012 IBC. FILE COPY Permit No. I Plan review approval is subject to errors and omissions. Approval of construction documents does not sus?:''' the violation of any adopted code or ordinance, of approved Field Copy and coneons is acknowledge a: By Date: / a/34o / 3 City Of Tukwila BUILDING DIVISION METAL STUD BRACING (4 MAX 6'-0' O.C. EXIST. STRUCTURE METAL TRACK 3 5/8' 20 GA. METAL STUDS @ 24' 0.C. 5/8' GYPSUM BOARD. PAINT TO MATCH EXIST. WALL BASE TO MATCH EXIST. EXIST. SLAB ON GRADE METAL ANGLE SUSPENDED CEILING PANEL 03/8' x4' EXPANSION ANCHOR BOLTS @ 8' O.C. METAL TRACK TYP. WALL DETAILS SCALE: 1" = 1'-0 +10TESI 1. LATERAL, BRACING CLUSTER: (4) 12 GA. GALV. SOFT—ANNEALED MILD STEEL WIRES SECURED TO MAIN RUNNER WITHIN 2" OF CROSS i` AND SPLAYED 90 DEGREES FROM EACH OTHER AT 45 DEGREES MAX. ABOVE HORIZONTAL. OLUSTERS'PIACED 12'-0" O.C. MAX. AND 6'—O" MAX. FROM EACH WALL. WIRES SHOULD BE TAUT WITHOUT CAUSING CEILING TO LIFT. 2. SUSPENSION WIRE: 12 GA. GALV. SOFT—ANNEALED MILD STEEL WIRE ENCASED IN ." DIAM. CONDUIT (FOR UPLIFT RESTRAINT); SECURE WIRE TO MAIN RUNNER WITHIN 2" OF CROSS 'r. CONDUIT TO OCCUR AT EVERY LATERAL BRACING CLUSTER AND SUSPENSION WIRES TO OCCUR AT 4'-0" O.C. MAX. EACH WAY. 3 TURNS MIN. WITHIN 3" TYP. NOTE #1 FASTEN RUNNERS TO PERIMETER WALL ANGLE AT (2) ADJACENT SIDES. PROVIDE MIN. 2" WIDE WALL ANGLE MAIN RUNNER, HEAVY DUTY CROSS 'T" 2" MAX. TYP. VIEW SHOWING LATERAL BRACING CLUSTER AND SUSPENSION WIRE NOTE #2 NOTE #1 RUNNER ENDS AT OPPOSITE WALLS TO FLOAT FREE ON PERIMETER ANGLE. PROVIDE 3/4" CLEARANCE BETWEEN ENDS OF GRID & WALL CEILING BRACING DIAGRAM SCALE: NO SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila «^=r!a-+ DIVISION 3S. 19' REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 2 2013 City of BUILDING cwila VISION 1. INSTALL OCCUPANCY SENSER AT RESTROOM & EXAM ROOMS. 2. INSTALL AUTOMATIC TIME SWITCH AT DISPLAY & WAITING AREA 1513.8.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically fuming off all the lights In an area, no more than 30 minutes after the area has been vacated. Light roans controlled by occupancy sensors shall have a waMraunted, manual switch capable of taming off lights when the space Is occupied. 1513.62 Automatic Time Switches: Automatic time switches shall have a minimum 7 day dock and be capable of being set for 7 different day types per week and Incorporate an automatic hcday'shut-ofr' feature, which turns off all loads for at least 24 tours and then resumes normally scheduled options. Automatic time switches shall also have program back-up capabilities, which prevent the loss of program and time settings for at least 10 hours, If power Is Interrupted. u, 3SD I n TRACK LIGHT 3 -WAY SWITCH (DIMMABLE) (E) FIRE SPRINKLER HEAD (E) AIR DIFFUSER 6' RECESS LIGHT >.< FLOURESCENT LIGHT 24x48 ACOUSTICAL CEILING TILE REFLECTED CEILING PLAN SCALE: 1/4" =1'-0" NO. 9 GA. LATERAL SUPPORT WIRE WITHIN 3' OF EACH CORNER OF LIGHT FIXTURE. SPLAY WIRES AS SHOWN AND FASTEN TO BEAM OR PURLIN. MIN. OF 3 WIRE TURNS EACH. CONNECTION POINT NO. 9 GA. LATERAL SUPPORT WIRE AT CENTER ENDS OF EA. FIXTURE. FIXTURE SUPPORT WIRE SUPPLIED BY CEILING CONTRACTOR ;4- LY`A' i� /'/ 60' MAX. TYP. 45' 45' RECESSED FLUORESCENT FIXTURE CROSS TIE MAIN STRUCTURAL RUNNER 4'-0" 0.0. O EXIST. 3/0 DOOR w/ CLOSER: CLOSER TO BE ADJUSTED FOR MIN. 5 SECS. FROM 90 DEGREE OPEN POS)T1ON TO 12 DEGREE. 5 WATTS ILLUMINATED EXIT SIGN wi EMERGENCY BACK UP POWER DISPLAY RECEPTION 12'-0' WAITING 11'3' EXAM #1 PHOTO EXAM #2 (E) ELECTRICAL PANEL (200AI�� V LIGHTING FIXTURE BRACING DIAGF:AM SCALE: NO REVISIONS No changes shall be made to the scope • of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fess. (E) HOT WATER TANK ALL NEW DOORS ARE 13/4' S.C. WOOD WITH LEVER -TYPE HANDLES MOUNTED BETWEEN 34' AND 48' HIGH. FLOOR PLAN SCALE: 1/4" =1'-0" SYMBOL REMOVED WALL EXIST. WALL NEW WALL RECEIVED NOV 0 7 2013 TUKWILA PUBLIC WORKS RECEIVED CITY OF TUKWILA NOV 0 5 2013 PERMIT CENTER 12220108th CT NE A111 KIRKLAND WA 98034 (M) 425.785.3992 (0) 425.285.9855 cchang03©yahoo.com CHAOHLIA CHAN STATE Of WASHINGTON 1-- Vl W 0 co >°3 r W m 09 8 P.11 wre W 4 o. 0 P. Z Z 0 g "tCL r W M 1 - NUMBER DATE DESCRIPTION OF REVISIONS 11-012013 PERMTSET SHEET TM.E SITE PLAN FLOOR PLAN DETAILS Al