Loading...
HomeMy WebLinkAboutPermit D13-0347 - WASHINGTON STATE NURSES ASSOCIATION - TENANT IMPROVEMENTWASHINGTON STATE NURSES ASSOC 575 ANDOVER PARK W surr 101 D13-0347 Parcel No: Address: Project Name: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 2623049144 575 ANDOVER PARK W Unit101 WASHINGTON STATE NURSES ASSOC Permit Number: Issue Date: Permit Expires On: D13-0347 12/4/2013 6/2/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SOUTHCENTER CORPORATE SQUAR 150 CALIFORNIA ST, SAN FRANCISCO, WA, 94111 SHANNON MILLER 635 ANDOVER PARK WEST, SUITE 1 , TUKWILA, WA, 98188 TCL PARTNERS CORPORATION 16000 MILL CREEK BLVD SUITE 1, MILL CREEK, WA, 98012 TCLPAPC919QD OWNER FUNDED Il/ Phone: (206) 575-3080 Phone: (425) 316-3500 Expiration Date: 7/10/2015 DESCRIPTION OF WORK: TENANT IMPROVEMENT TO THE 1ST FLOOR SUITE FOR OFFICE USE TO INCLUDE THE DEMOLITION OF EXISTING PARTITIONS & ADDITION OF NEW PARTITIONS, DOORS, RELITES & NEW FEATURES. Project Valuation: $15,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: NO Type of Construction: VB Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Fees Collected: $638.60 Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: • • Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: l9-- I hearby certify that I have read and : ned this permit and know the same to be true and correct. All provisions of law and ordinances gove : this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit'V�and agree to the conditions attached to this permit. C�7 Signature: 164/4S Print Name: grrininbil N, l�iIice/ Date: I -2--(41 I 3 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 5: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. �►• 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 13: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 14: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 15: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 16: Maintain fire extinguisher coverage throughout. 17: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 18: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 19: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 21: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 22: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 23: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 24: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power Toss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1006.1, 1006.2, 1006.3) 25: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 26: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 27: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 30: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 31: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 33: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.gov Building Permit No., Project No. Date Application Accepted: Date Application Expires: 51("P-1 (For office use only) /2)-03 4-(7 CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: "✓ % v c1v' €V r a r i ry ect King Co Assessor's Tax No.: 20'2—Q--ict}if+ Suite Number: 10 Floor: 1 Q1 Tenant Name: %jh‘1 v1/1� /N ea AC X` New Tenant: ❑ Yes S...No PROPERTY }OWNER Name:9-y e 110 covpvv i vAlic �, Address4 1. /I ,iAwl/ -jj 51: 4 19AA9 City: sQ1� Sta_te:: , kip_ Zipp::1610i CONTACT PERSON- person receivingall project•, communication Name: c'1An11AnOn 0Alai( ::(O��� Addressw'vtcv .,pitby, C_� �I City: ''�r�/�Iaj State: WA,- Zip:� �rldi Phon (0) �rf,, QFax: (2°")�!'jrj 4Ig J Email:* iviilleVe (ilitiv etavV IIN1' cowl GENERAL CONTRACTOR INFORMATION Company Name: Address: Address: 'L(:://�"'�v�1e ; Ave. N is 1 City: S �'�' State: ror zipoicucci Phone: `r 200 4.14 "t Fax: City: State: Zip: Phone: Fax: City: State: Contr Reg No.: Phone: Exp Date: Tukwila Business License No.: H;\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh ARCHITECT OF RECORD ; 104440w," Company Name: ir,, la fcs Architect Name: 'j eti v ( iF .e l'tG Address: 'L(:://�"'�v�1e ; Ave. N is 1 City: S �'�' State: ror zipoicucci Phone: `r 200 4.14 "t Fax: Email. I.roifiwn mAvicpl:r . cvw' ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDERBOND ISSUED (required for projects $5,000 or greater per RCW 19-27-095) Name: Address: City: State: Zip: Page 1 of 4 • • BUILDING PERMIT INFORMATION''= 206-431-3670 Valuation of Project (contractor's bid price): $ 000 Describe the scope of work (please provide detailed information): Existing Building Valuation: $ 100G 000 -tenctot metyvtivehletAi o1 tstfi(QOV cioile -fry of-fic.e vse. lo'Demote -tvw Benno I,if►wv1 ofi e) tstiv►S pav ►ti ov1s 1;,Laad(1i OV1of vow doovst ve 14eS vvwf-ecawes. Will there be new rack storage? ❑ Yes licit+No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 1st Floor, Interior Remodel Addition to Existing Structure. Type of Constructiort per CIBC Type of,, of Occupancy per IBC 01,4k(o Y Ovle mine v X13 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached" Garage' Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ). Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Saf Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line1201 I Applications\Permit Application Revised - 8-9-I l.docs Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION - 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. W ter District Tukwila ❑...Water District #125 ❑ .. Highline ...Water Availability Provided ❑ .. Renton Se er District Tukwila ❑ ... Valley View ❑ .. Renton ❑ .. Seattle ❑ ...Sewer Use Certificate ❑ ... Sewer Availability Provided Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way El Non Right-of-way ❑ ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) 0 ...Traffic Impact Analysis 0 ... Hold Harmless — (SAO) El ... Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone El .. Storm Drainage ❑ ...Sanitary Side Sewer 0 .. Abandon Septic Tank 0 .. Grease Interceptor ❑ ...Cap or Remove Utilities 0 .. Curb Cut 0 .. Channelization 0 ...Frontage Improvements 0 .. Pavement Cut 0 .. Trench Excavation 0 ...Traffic Control 0 .. Looped Fire Line ❑ .. Utility Undergrounding El ...Backflow Prevention - Fire Protection Irrigation " Domestic Water ❑ ...Permanent Water Meter Size... 51 WO # ❑ ...Temporary Water Meter Size .. 59 WO # ❑ ...Water Only Meter Size WO # 0 ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public 0 Private ❑ 0 ...Water Main Extension Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\Forms-Applications On Line\201 I Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 3 of 4 BERMITAIPPLICATION NOTES At, °Lj.;j- T.%I8 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. • BUILDING 0 R AUTHORIZE'/D�AGENT: Signature: ,n L V `, Date: rte► Print Name: S�atvr 1v 1 t' toitleV Day Telephone: C-2100)1 Mailing Addresst400 NUw( v'• F' WCt +1°1 1 1U 41 t I°1 W f CiCa" City H:\Applications\Forms-Applications On Line \2011 Applications \Permit Application Revised - 8-9-11.docv Revised: August 2011 bh State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT 1 QUANTITY PAID PermitTRAI $292.50 $1i Address: 575 ANDOVER PARK W Unit101 Apn: 2623049144 $292.50 DEVELOPMENT $292.50 PERMIT REINSPECTION FEE TOTAL FEES PAID BY RECEIPT: R1874 R000.322.800.00.00 $292.50 $292.50 Date Paid: Tuesday, April 22, 2014 Paid By: TCL PARTNERS CORPORATION Pay Method: CREDIT CARD 01251G Printed: Tuesday, April 22, 2014 9:30 AM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ( PermitTRAK ACCOUNT I QUANTITY I PAID $638.60 D13-0347 Address: 575 ANDOVER PARK W 1 Apn: 2623049144 $638.60 DEVELOPMENT $638.60 PERMIT FEE 000.322.100.00.00 $384.30 PLAN CHECK FEE 000.345.830.00.00 $249.80 WASHINGTON STATE SURCHARGE TOTAL FEES PAID BY RECEIPT: R83 640.237.114 $4.50 $638.60 Date Paid: Tuesday, November 12, 2013 Paid By: SOUTHCENTER CORP SQUARE LLC Pay Method: CHECK 5347 Printed: Tuesday, November 12, 2013 4:06 PM 1 of 1 IRWSYSTEMS wt INSPECTION RECORD Retain a copy with permit13- q INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: �.) 5`,iit AL -' Type of Inspection: f- N4/ ' /PtFQ Y</4 h" Address: 75 4P6j Date Called: Special Instructions: z/412//10( 940 Date Wanted:___a. 7-.,2 _�V Requester: / Phone No: x/1.1;1 ®Approved per applicable codes. Corrections required prior to approval. COMMENTS: x/1.1;1 -1e (, ,,o // ) N'' L-- "xr imrt j: teirj2 Cc—L /� Da— 2 — ,�' EnRR(NSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 810 6t3-o3Li Project: ` 0 tic SI i G Ntt 41-5 Type of Inspection: g-vy‘ e v �7 >: old 1/4( Lit( kt Address: 75 PtQs.Ia.1e✓ FP 14 vie Date Called: -+- Special Instructions: Date Waged: Z-3 1 i p'm' Requester: 6v-iFlt\.1 Phone No: 1-1.2:% -3340-2-001 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: CD L - GIt Q tom\ t.1 s �a r C ,1; �,5 , o .pt o, t Date 2 3 1 ECTION FEE REQUIR Prior to next inspection. fee must be 6300 Southcenter Blvd.. uite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit I i3-c3y? PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188. (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Projec :Type 4-s h 5-14114' :Ph of Inspection: F i .. ili) 6 Address: 57s AAJtavgk P 1 Date Called: Special Instructions: y VI/J/416/ Date Wanted: S-( 1 a�.m;. , Requester: Phone No: 24 s -v7o 9.R (75 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: INSPECTION FE: REQUIRED. P ionto next. inspection, fee must be paid at 6300 Southcenter Blvd.. Sui a 100. Call to schedule reinspection. i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 03((7 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 1,)(4 Si PlArSe_g Tyke of nsp ction: )---74--/SP/ '1/QA-?.-.-- Address: 5-7 s-- 4 P Suite #: Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: - A- %SP - v . Pre -Fire: Permits: Occupancy Type: r /'P 4)(iu,4'L- • Ci . J,7 (R4c;I�,7 Ux' ,c,�L. E/L. --rt.;,zq_ /4,0 . Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 1h --. Date: 7/9///67 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 7/1/2014 City of Tukwila Department of Community Development SHANNON MILLER 635 ANDOVER PARK WEST, SUITE 1 TUKWILA, WA 98188 RE: Permit No. D13-0347 WASHINGTON STATE NURSES ASSOC 575 ANDOVER PK W, SUITE 101 Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 8/24/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 8/24/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D13-0347 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Date: ij-" ; OFF HOURS INSPECTION Reimbursement authorization/approval to conduct inspection activities during off hours. Permit Number: 1i / .3 'L• 3 4' f L ( Requested By: Firm/Company: r Pad- - i1 c r`K Inspection Information Project Name: c3 A 1.A -e Pui• 6e A Project Address/Location: .5-7 Y At Iva r Crim I y�a._y }• Requested Date for Inspection: e/ -v-3 `" /y Contact Name: r t.- C'F Special Conditions for Consideration: Requested Time:.- 7 ?0 9/PM Phone Number: q,,c 3 O — 2 (3 et)�e"N a r' t� c.1 n c �� cS Contractor will be charged a minimum for three (3,t g()hour inspection time for any off -hours inspection work at $97.50 per hour (minimum total of $292.50). This is to be paid at the time of request. ** T 4M /+APe.C1A.? tOe.,l.4, The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice will be issued for all inspection time in excess of (3) hours. Signature: Printed Name: Date: Y --„Ll - % City Use Only: Approved: Disapproved: Date of Approval/Disapproval: 1 - Authorized Reviewer: A1.11 r,Ib 70Wim_ \ a igcC r r+seGLA'- me ►s AL -t0 OOZE) -1-b Kl" 7&i !WS/ ( -),i- tiNki L6Ai6tT`' . Paid: f'lI Zi (L-1, Receipt No: fj ;54 1 Remarks: I1IJJ k 5L0 lo•k1i..1- CA 91{1Alt` A'A6i (kfA-C. i`Jl�t t ` t b/{rid. 111,iq • fWA- 0,\De/ kx; ht—b iv") P4' H:\Permit Center Forms\Off Hours Inspection.docx • PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-0347 DATE: 11/12/13 PROJECT NAME: WASHINGTON NURSES ASSOCIATION SITE ADDRESS: 575 ANDOVER PK W, STE 101 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Nc Building Division Public Works 6 Fire Prevention Structural El 22.0 N Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11/14/13 Complete tr Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 12/12/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Joanna Spencer From: Todd Reedy Sent: Monday, November 18, 2013 8:15 AM To: Joanna Spencer Subject: RE: WA Nurses Assoc @ 575 APW D13-0347 Good Morning Joanna, I am happy to report that 575 APW is current on backflow preventer installation and testing. Have a good day, Todd From: Joanna Spencer Sent: Friday, November 15, 2013 10:33 AM To: Todd Reedy Subject: WA Nurses Assoc @ 575 APW D13-0347 Happy Friday, Are they current on the backflows ? JJs PERMANENT FILE COP) 1D13-0347 Jennifer Marshall From: Jennifer Marshall Sent: Wednesday, November 13, 2013 8:46 AM To: smiller@pinnaclefamily.com Subject: D13-0347, WA Nurces Association Good morning Shannon, As I was routing the paperwork for plan review for the above referenced tenant improvement, I noticed that the lender information was not completed on the application. The review can continue without this information, but it will be required prior to permit issuance. If you have any questions, feel free to contact me. Take care, )ennifer Marshall Permit Technician, City of Tukwila T: 206 431-3670, F: 206 431-3665 The City of opportunity, the community of choice. 1 Contractors or Tradespeople Peer Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TCL PARTNERS CORPORATION UBI No. 602930767 Phone 4253163500 Status Active Address 16000 Mill Creek Blvd License No. TCLPAPC919QD Suite/Apt. SUITE 103 License Type Construction Contractor City Mill Creek Effective Date 11/4/2009 State WA Expiration Date 7/10/2015 Zip 98012 Suspend Date County Snohomish Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status JBSCOC'916MSJB5 CORPORATION Construction Contractor General Unused 7/10/2009 7/10/2011 Inactive Business Owner Information Name Role Effective Date Expiration Date SYLESTER, FRANCES MARIAN Agent 11/04/2009 Amount MERISKO, CARL WILLIAM Chief Financial Officer 06/22/2011 DTC05A09225ATIL13 MERISKO, BRIAN JAMES President 11/04/2009 MERISKO, DAVID JAMES Secretary 11/04/2009 Travelers Indemnity Co of Ame SYLVESTER, SUSAN MARIE Treasurer• 11/04/2009 SYLVESTER, SCOTT JAMES Vice President 11/04/2009 6 SYLVESTOR, JAMES RAYMOND Vice President 11/04/2009 09/06/2012 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 American Contractors Indem CO 100087506 11/04/2009 Until Cancelled $12,000.00 07/10/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 Travelers Property Cas Co of A DTC05A09225ATIL13 09/06/2013 09/06/2014 $1,000,000.0009/05/2013 7 Travelers Indemnity Co of Ame DTC05A09225ATIL11 09/06/2012 09/06/2013 $1,000,000.0009/12/2012 6 Travelers Property Cas Co of A DTSMCUP5A09225ATIL11 09/06/2011 09/06/2012 $4,000,000.0009/10/2011 5 Travelers Property Cas Co of A BA5A09225ACNS11 09/06/2011 09/06/2012 $1,000,000.0009/10/2011 4 Travelers Property Cas Co of A DTC05A09225ATIL11 09/06/2011 09/06/2012 $1,000,000.0009/10/2011 3 SCP0828666 10/27/2010 10/27/2011 $1,000,000.00 06/07/2011 https://fortress.wa.gov/lni/bbip/Print.aspx 12/04/2013 01 \WSNA 2013\Working Drawings\(TI-1) SCCS—BLDG3—WSNA—CV-01.dwg 0 0 0 0 V) 0 O cn 2 ACT ADJ AFF ALT ALUM APPROX BLDG BLKG B/S CAB CLR CLG CL COL COMM COMP CONST CONT CPT CT DIA DIM DR DW DWG E EA ELEC ELEC'L ELEV EXIST EXT FIN FLR FLUOR FMC FR FT FURN GA GALV GD GL GWB HC HDW HM HT HVAC IN INCL INSUL INT ACOUSTICAL CEILING TILE ADJACENT / ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM APPROXIMATELY AT BUILDING BLOCKING BUILDING STANDARD CABINET CLEAR/CLEARANCE CEILING CENTERLINE COLUMN COMMUNICATION COMPOSITION CONSTRUCTION CONTINUOUS CARPET CERAMIC/CONCRETE TILE DIAMETER DIMENSION DOOR DISHWASHER DRAWING EXISTING / EAST EACH ELECTRIC ELECTRICAL ELEVATION (VIEW) EXISTING EXTERIOR FINISH FLOOR FLUORESCENT FLOOR MATERIAL CHANGE FIRE RATED FEET FURNISH / FURNISHINGS GAUGE GALVANIZED GARBAGE DISPOSAL GLASS / GLAZING GYPSUM WALL BOARD HOLLOW CORE HARDWARE HOLLOW METAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR ABBREVIATIONS JT LL@TE LF MAX MECH MFR MIN MISC MTD MTL MW N N/A NIC NO NOM NTS OC OPNG OPP ORIG PERM PL PLAM PLYWD PR PTN R RB REF REINF REQ'D REV RM RO S SCHED SC SECT SIM SPEC SQ STD STL STOR SUSP TEL TSG TYP VCT VERT WI W/O WC WD JOINT BY LANDLORD AT TENANTS EXPENSE LINEAL FOOT MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL MICROWAVE OVEN NORTH/NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIGINAL PERMANENT PLATE PLASTIC LAMINATE PLYWOOD PAIR PARTITION RADIUS / REMOVE / RELOCATE RUBBER BASE REFRIGERATOR REINFORCING REQUIRED REVISION / REVERSE ROOM ROUGH OPENING SOUTH SCHEDULE SOLID CORE SECTION SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TELEPHONE TEMPERED SAFETY GLASS TYPICAL VINYL COMPOSITION TILE VERTICAL WEST WITH WITHOUT WALLCOVERING WOOD NA AREA OF WORK EXISTING (2) STORY OFFICE BUILDING EXI I • NO CHANGE TO BUILDING AREA • NO EXTERIOR WORK • NO CORE/SHELL WORK • NO STRUCTURAL WORK • NO CHANGE OF USE OCCUPANT LOAD CALCULATION TOTAL SUITE SQUARE FOOTAGE: OCCUPANCY LOAD FACTOR: TOTAL: 8,601 / 100 = 86OCCUPANTS (2) EXIT(S) REQUIRED PER TABLE 1015.1; (2) EXIT(S) PROVIDED OCCUPANCY LOAD CALCULATION AND KEY PLAN 21 ISI NA NA 4=6": Il I I -I f Z I/1 7 7 Z 7 7 Z Z L Z Z 7 iU 7 Z Z Z 7 NO1E: MAINTAIN EXISTING ONE FOOTCANDLE PER SQUARE FOOT AT EGRESS PATHWAY LIGHTING. LONGEST COMMON PATH OF EGRESS TRAVEL: 36'-8" EGRESS TRAVEL INFORMATION COMMON PATH OF EGRESS TRAVEL (SPRINKLERED) MAXIMUM DISTANCE = 100' (PER SECTION 1014.3) TRAVEL DISTANCE (SPRINKLERED) MAXIMUM DISTANCE = 300' (PER TABLE 1016.1) NORTH DESIGNATED EGRESS PATH (HATCHED AREA) Z 7 NEW OR RELOCATED B/S 2X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY. L I 7 NTS V-6" 7 mt- NORTH VICINITY MAP 12 BLDG 3 1 C MINKLER BLVD. ANDOVER PARK W. NORTH SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION NOT A LEGAL SURVEY SITE PLAN 4'-0" WIDE ACOUSTIC BATT INSULATION CENTERED OVER PARTITION ABOVE HUNG CEILING. 1/4" NON-COMBUSTABLE WOOD FILLER UNDER MAIN RUNNERS. CEILING @ + 8'-3" A.F.F. (WHERE INDICATED ON REFLECTED CEILING PLAN). CONTINUOUS 'L' METAL TRIM W/ PAPER WING (BOTH SIDES OF PARTITION) ACOUSTIC BATT INSULATION . GALV. STEEL SILL TRACK. ATTACH TO STRUCTURE WITH HILTI X -U (OR XU15) UNIVERSAL KNURLED SHANK POWDER DRIVEN FASTENER WITH MIN. 1" EMBEDMENT @ 16" O.C. (FOLLOW MANUFACTURER'S INSTRUCTIONS). FLOORING AS SCHEDULED (BOTH SIDES OF PARTITION) STUD SCHEDULE (_ ( ) ) ) STUD SCHEDULE: 2-1/2" = 250S125-27 (22 GA); MAX 10'-0" HIGH. 3-5/8" = 362S125-27 (22 GA); MAX 13'-0" HIGH. 6" = 600S125-27 (22 GA); MAX 17'-6" HIGH. NOTES: 1. ALL STUDS ARE AT 16" O.C. 2. USE SAME GAUGE AS STUDS FOR TRACKS AND CHANNEL. 3. USE SSMA TECHNICAL GUIDES. SEISMIC BRACING (BEYOND) PER 11/TI-1. 1/8" BLACK FOAM TAPE, HOLD BACK 1/4" FROM EDGE OF TRACK (BOTH SIDES) METAL TRACK WITH (2) #10 SCREWS AT 16" O.C. REVEAL (PAINT BLACK) OR MATCH EXISTING CONDITION. (BOTH SIDES OF PARTITION) 5/8" FIRE RETARDANT TREATED PLYWOOD BLOCKING AT WALL HUNG ITEMS (WHERE APPLICABLE- REFER TO DRAWING PLANS). ALTERNATE FOR BLOCKING: 20" WIDE SHEET METAL AT +40" FROM FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING) 5/8" GWB, TYPE 'X' EACH SIDE BASE, AS SCHEDULED. (BOTH SIDES OF PARTITION.) EXISTING STRUCTURE (BELOW) GALV STEEL STUD, PER STUD SCHEDULE, WITH 5/8" TYPE 'X' GWB EACH SIDE. NA NA EGRESS PLAN NA STANDARD TENANT SOUND PARTITION 1-1/2"=1'-0" EXISTING STRUCTURE METAL CLIP METAL STUDS STAGGERED @ 8'-0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12'-0". ATTACH TO STRUCTURE ABOVE. (2) #10 SCREWS SCHEDULED CEILING TILE & GRID 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX -2' MAX y y y 'TO END I I OF WALL 'OMITBJCINGAT WALL LATERAL BRACING (STAGGERED) PER / ITOP OF WALL DETAIL ABOVE (TYP.) LATERAL WALL BRACING PLAN VIEW NTS NOTES: 1. LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FEET O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FEET LONG. (PER TYPICAL PARTITION PLAN) 2. PROVIDE BRACING AT ANY PERMANENT PARTITION THAT IS NOT ATTACHED TO CEILING GRID. TI -1 COVER SHEET AND DETAILS TI -2 DEMOLITION PLAN AND CONSTRUCTION / ELEC./COMMUNICATION PLAN TI -3 REFLECTED CEILING PLAN, FINISH PLAN AND FINISH SCHEDULE I REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 1 NA NA 10 NA NA 11 STANDARD HEAD BRACING NA 12 SHEET INDEX NA SCOPE OF WORK MINOR TENANT IMPROVEMENT TO AN EXISTING OCCUPIED FULL FLOOR SUITE ON THE FIRST FLOOR FOR OFFICE USE TO INCLUDE: • DEMOLITION OF PARTITIONS • CONSTRUCTION OF PARTITIONS • CONSTRUCTION OF CASEWORK • NEW PAINT AND FLOORING THROUGHOUT SUITE • INSTALLATION OF NEW LIGHT FIXTURES • NO STRUCTURAL WORK • NO ALTERATIONS OF CORE. AREA OF SUITE: 8,601 SQ.FT. OCCUPANCY TYPE: B - OFFICE CONSTRUCTION TYPE: V -N, SPRINKLED APPLICABLE CODES: 2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL FIRE CODE 2012 INTERNATIONAL PLUMBING CODE 2012 INTERNATIONAL MECHANICAL CODE 2012 NATIONAL ELECTRICAL CODE ICC/ANSI 117.1= ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES WASHINGTON STATE ENERGY CODE (WSEC), WAC 51-11 WASHINGTON INDOOR AIR QUALITY CODE ASSESSOR'S PARCEL #: 2623049143 LEGAL DESCRIPTION LOT 3 OF CITY 9F TUKWILA SHORT PLAT NO L97-0049 RECORDING NO 9711069009 SAID SHORT PLAT DEFINED - PORTION OF E 1/2 OF NW 1/4 OF SE 1/4, BEGIN NE CORNER OF SAID E 1/2 BEING N 88-05-42 W 1339.34 FT FROM NE CORNER OF SE 1/4TH S 01-47-29 W 1322.34 FT TO SOUTHEAST CORNER TH N 87-55-02 W 659.35 FT TO W LINE OF E 659.34 FT OF SAID E ' /2 TH N 01-47-29 E 1320.30 FT TO N LINE OF SAID E 1/2 TH S 88-05-42 E 659.34 FT TO POB LESS PORTION FOR 59TH AVE SOUTH LESS PORTIONS FOR STREETS AS CONVEYED BY DEED, RECORDING NO 7907120770 LESS PORTION CONVEYED TO CITY OF TUKWILA FOR ROAD BY DEED, RECORDING NO 9408290327 PROJECT DIRECTORY TENANT WASHINGTON STATE NURSES ASSOCIATION BUILDING REPRESENTATIVE PINNACLE FAMILY OF COMPANIES 810 THIRD AVENUE, SUITE 140 SEATTLE, WASHINGTON 98104 CONTACT: TAMARA K. MALONE' TELEPHONE: (206) 903-0662 FAX: (206) 903-0668 EMAIL: tmaloney@pinnaclefamily.cm DESIGNER MARVIN STEIN AND ASSOCIATE',, LLC 1500 WESTLAKE AVE. N, SUITE O'-lE SEATTLE, WASHINGTON 98109 CONTACT: JENNI KENISTON TELEPHONE: (206) 441-1449 EMAIL: j.keniston@marvinstein.com CONTRACTOR TBD REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of la BUILDING ISION MECHANICAL, PLUMBING, FIRE PROTECTION AND LIFE SAFETY NOTES 1. MECHANICAL, FIRE PROTECTION AND LIFE SAFETY ALTERATIONS AND CONSTRUCTION ARE BY OTHERS, UNDER SEPARATE PERMITS BY DESIGN BUILD CONTRACTORS - DEFERRED SUBMITTALS. 2. REBALANCE THE HVAC SYSTEM AND PROVIDE WRITTEN REPORT TO OWNER AND/OR ARCHITECT. 3. CLEAN ALL DIFFUSERS & GR'LLS. 4. VERIFY LOCATION OF THERMOSTATS WITH OWNER OR ARCHITECT PRIOR TO FINAL INSTALLATION. 5. ALL CONSTRUCTION WORK I3 CONFINED TO THE BUILDING INTERIOR. CONTRACTOR SHALL PROVIDE BARRIERS OR SYSTEMS TO CONTAIN DUST, DIRT OR DEBRIS TO MINIMIZE INCONVENIENCE TO OTHER TENANTS WITHIN THE BUILDING. 6. CONSTRUCTION OPERATIONS SHALL NOT OBSTRUCT HALLWAYS, CORRIDORS, STAIRWAYS OR MEANS OF EGRESS FOR THE TENANTS OF THE BUILDING. 7. DO NOT DISRUPT HVAC, PLUMBING, ELECTRICAL OR FIRE PROTECTION SYSTEMS WITHOUT PRIOR AUTHORIZATION FROM OWNER. 8. THE CONSTRUCTION SITE SHALL BE LEFT CLEAN & ORDERLY AT THE END OF EACH WORK DAY. 9. NO ONE WILL OCCUPY THE AREA OF WORK OTHER THAN AUTHORIZED CONSTRUCTION PERSONNEL. 10. THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION BARRIERS TO INHIBIT ACCESS BY NON -AUTHORIZED PERSONNEL & AS REQUIRED BY O.S.H.A. STANDARDS TO PREVENT INJURIES OR ACCIDENTS. 11. N.F.P.A. / I.F.C. APPROVED FIRE EXTINGUISHERS SHALL BE LOCATED WITHIN 75 FEET FROM ANY POINT ALONG THE PATH OF TENANT EGRESS ORAS REQUIRED BY THE LOCAL FIRE MARSHAL. 12. THE SPACE AROUND PIPES DUCTS ETC. PENETRATING FIRE RESISTANT CONSTRUCTION SHALL NOT EXCEED 1/2' & SHALL BE PACKED SOLID WITH APPROVED FIRE SAFING MATERIAL & SEALED WITH METAL ESCUTCHEONS EACH SIDE AS REQUIRED BY CODE. 13. MAINTAIN INTEGRITY OF RATED ASSEMBLIES AND REPAIR ANY DAMAGE TO SPRAY APPLIED FIRE PROOFING. GENERAL NOTES 1. COMPLY WITH ALL APPLICABLE CODES. 2. THE GENERAL CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY THE FIELD CONDITIONS PRIOR TO PURCHASING MATERIALS OR COMMENCING THE WORK. 3. REPORT ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND DRAWINGS TO ARCHITECT BEFORE PROCEEDING WITH THE WORK. 4. VERIFY THE BUILDING STANDARDS (B/S) BEFORE PROCEEDING WITH THE WORK. 5. OBTAIN ALL REQUIRED PERMITS AND APPROVALS BEFORE PROCEEDING WITH THE WORK. 6. WALLS, PARTITIONS AND CEILINGS SHALL BE INDEPENDENTLY BRACED TO RESIST SEISMIC FORCES. 7. PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS. 8. ALIGN AND SHIM TRANSITIONS BETWEEN OLD AND NEW CONDITIONS. 9. LEVEL THE FLOOR. DEVIATIONS OF ± 1/2" WITHIN 10'-0" IS THE ACCEPTABLE LIMIT. 10. GENERAL CONTRACTOR REVIEW AND STAMP OR MARK REQUIRED SUBMITTALS AND SHOP DRAWINGS PRIOR TO SENDING COPIES TO MSA FOR REVIEW AND COMMENT. 11. THE BUILDING OWNER OR THE OWNER'S AUTHORIZED REPRESENTATIVE SHALL ESTABLISH WORKING TIME AND STANDARDS OF CONDUCT. 12. DO NOT SCALE DRAWINGS. 13. THE GENERAL CONTRACTOR SHALL COORDINATE THE ACTIVITIES OF ALL SUBCONTRACTORS, DELIVERY, AND THE STAGING OF MATERIALS. 14. GENERAL CONTRACTOR SHALL NOT START CASEWORK UNTIL CONFERENCE / COPY / BREAK / WORK ROOM CASEWORK SHOP DRAWINGS HAVE BEEN REVIEWED BY MSA. SOUTHCENTER CORPORATE SQUARE BUILDING 3 575 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 FILE COPY Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved /F`iie�lld� Copy and , ' is acknowledged: Pr� 21 1 � Date: �-I City Of TlukwiIa BUILDING DIVISION r 1500 WESTLAKE AVE N SUITE ONE, SEATTLE WA, 98109 (206) 441-1449 NO. DRAWN BY: JK CHECKED BY: LD JOB NO.: 99135.092 REVISIONS INDICATED THUS 0 PERMIT SET ISSUED FOR REVIEW PERMIT SET CONSTRUCTION SET DATE 10/22/13 10/24/13 11/07/13 CITY OF TUKWILA PERMIT CENTER TENANT: WASHINGTON STATE NURSES ASSOCIATION (FIRST FLOOR REMODEL) SHEET TITLE: COVER SHEET AND DETAILS 1)199 -0L -ii �I REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2013. • L.=. Lam: 0 G DEMOLITION LEGEND DEMOLITION NOTES SOUTHCENTER CORPORATE SQUARE BUILDING 3 EXISTING BUILDING CORE TO REMAIN. EXISTING CONSTRUCTION TO REMAIN. EXISTING CONSTRUCTION TO BE DEMOLISHED. DEMOLITION KEYNOTES OREMOVE SECTION OF EXISTING CLOSET COAT RACK AND SHELF. SEE CONSTRUCTION PLAN 2/TI-2. 0 EXISTING UPPER CABINETS TO REMAIN. 1. A CLEAR PATH OF EGRESS TRAVEL SHALL REMAIN OPEN AT ALL TIMES DURING DEMOLITION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES AND THE BUILDING MANAGEMENT. 3. ALL DEBRIS SHALL BE REMOVED FROM THE CONSTRUCTION SITE DAILY. 575 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 4. ALL DEMOLITION SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING MANAGEMENTS RULES AND REGULATIONS WITH MINIMAL DISTURBANCE TO OTHER TENANTS. 5. THE CONTRACTOR SHALL PROVIDE DUST BARRIERS FOR PROTECTION OF EXISTING ADJACENT AREAS. ALL HVAC SYSTEMS ARE TO BE PROTECTED DURING DEMOLITION. 6. THE CONTRACTOR SHALL NOTIFY THE OWNER AND MSA OF ANY DEMOLITION WORK THAT IMPACTS THE STRUCTURAL INTEGRITY OF THE BUILDING. 7. THE GENERAL CONTRACTOR SHALL IMMEDIATELY REPORT ALL ACCIDENTS, ERRORS OR DEFECTS TO THE BUILDING MANAGEMENT. DEMOLITION PLAN 1/8" =1-0" NORTH OFFICE (EXISTING) OFFICE (EXISTING) VESTIBULE (EXISTING) OFFICE (EXISTING) OPEN OFFICE CONFERENCE (EXISTING) OFFICE (EXISTING) F1T1 OFFICE (EXISTING) 136 CONSTRUCTION LEGEND r) 0• J 0_ w (f) 1 Jco cn c) U) N i 0 0 0 0 N ¢ 0 0 (1) 0 0 0 0 0 0 0 u_ cacsi c O 0 I.7 CO Nm Q 1 0¢ UZ N 0 NO 0 Ur 0 CO %i) N U 1 U mm ��� HALLWAY 123 HALLWAY SERVER (EXISTING) OFFICE (EXISTING) OFFICE (EXISTING) EXISTING BUILDING CORE. EXISTING CORRIDOR PARTITION. NEW BIS SOUND PARTITION. SEE DETAIL 8/TI-1. EXISTING B/S FULL -HEIGHT TEMPERED SAFETY GLASS RELITE. 1 j ALIGN. OFFICE (EXISTING) (2) PANELS FILE ROOM (EXISTING) SERVER ROOM (EXISTING) WORK ROOM (EXISTING) CONFERENCE �U 128 OPEN OFFICE 22'-6" COPY/ WORK RECEPTION (EXISTING) OFFICE (EXISTING) ELEC / COMMUNICATIONS LEGEND OFFICE (EXISTING) 1116 1 OFFICE (EXISTING) 115 WORK ROOM (EXISTING) BOARD ROOM (EXISTING) CONSTRUCTION NOTES 1500 WESTLAKE AVE N, SUITE ONE, SEATTLE WA, 98109 (206) 441-1449 1. MAINTAIN A CLEAR PATH OF TRAVEL AT ALL TIMES DURING CONSTRUCTION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & THE BUILDING OWNER / MANAGEMENT AND TENANT. 3. INSTALL DOUBLE STUDS AT DOOR JAMBS AND HEADERS. 4. PROVIDE FIBER GLASS REINFORCED WATER RESISTANT GYPSUM BOARD IN AREAS SUSCEPTIBLE TO MOISTURE. 5. DIMENSIONS ARE FINISH SURFACE TO FINISH SURFACE, U.N.O. 6. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS TO THE ARCHITECT. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 DRAWN BY: JIN CHECKED BY: LD JOB NO.: 99135.092 NO. BIS WALL MOUNTED DUPLEX ELECTRICAL OUTLET. B/S WALL MOUNTED DEDICATED 120V 20A DUPLEX ELECTRICAL OUTLET. B/S WALL MOUNTED COMBINATION VOICE/DATA OUTLET. UPGRADED EXISTING. REVISIONS INDICATED THUS A PERMIT SET ISSUED FOR REVIEW PERMIT SET CONSTRUCTION SET DATE 10/22/13 10/24/13 11/07/13 BY JK JK JK VESTIBULE (EXISTING) OPEN OFFICE OPEN OFFICE HALLWAY OFFICE (EXISTING) OFFICE (EXISTING) OFFICE (EXISTING) —I 112 OFFICE (EXISTING) OPEN OFFICE OFFICE (EXISTING) CONFERENCE (EXISTING) —I 106 BREAK ROOM (EXISTING) ELEC. / COMMUNICATION NOTES 1. ALL ELECTRICAL OUTLETS TO BE MOUNTED AT 15" A.F.F. (AT BASE OF OUTLET) PER W.S.B.C. REQUIREMENTS U.N.O. CONSTRUCTION KEYNOTES 0 PROVIDE AND INSTALL BUILT-IN B/S FULL HEIGHT MELAMINE ADJUSTABLE STORAGE SHELVING. WIDTH PER PLAN. COORDINATE WITH TENANT. OZ PROVIDE AND INSTALL BLOCKING IN EXISTING PARTITION AT THIS LOCATION TO SUPPORT NEW TENANT PROVIDED SIGNAGE. COORDINATE WITH TENANT. O3 PATCH AND PREP EXISTING PARTITION AFFECTED BY DEMOLITION TO RECEIVE PAINT. 2. ROUGH IN ALL DATA AND COMMUNICATION LINES - MUD RING WITH PULL STRING, U.N.O. 3. PROVIDE NEW COVER PLATES AND RECEPTACLES AS NEEDED TO MATCH BUILDING STANDARD. 4. MAINTAIN EXISTING ELECTRICAL OUTLETS UNLESS LOCATION CONFLICTS WITH NEW CONSTRUCTION. 5. THE CONTRACTOR SHALL COORDINATE ELECTRICAL, LIGHTING, CASEWORK AND FURNITURE. TENANT: ELEC / COMMUNICATIONS KEYNOTES E1 CONTRACTOR TO PROVIDE ALTERNATIVE OPTIONS AND PRICING FOR RUNNING POWER AND VOICE/DATA CORDS UNDER CARPET FROM WALLS TO CENTER OF BOARD ROOM. COORDINATE WITH TENANT. E2 SEE REFLECTED CEILING PLAN 1/TI-3 TO PROVIDE REQUIRED REQUIRED POWER AND VOICE/DATA FOR CEILING MOUNTED PROJECTOR. COORDINATE WITH TENANT. WASHINGTON STATE NURSES ASSOCIATION (FIRST FLOOR REMODEL) CONSTRUCTION AND ELEC./COMMUNICATION PLAN 1/8" =1'-0" SHEET TITLE: DEMOLITION PLAN AND CONSTRUCTION / ELEC./COMMUNICATION PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2013. TI -2 OF OUTHCE TER CORPORATE SQUARE 0" O 0 L o 1O or) � l— e- 0 I o U Z o QN) U � 4., 1=1 om iv, NJ U 1 U Cn (I) U) I mm CD N ��� ECL Cf) ..-U >,_ a�cn =60 0, �1-oo� OF-cnDx —1 120 —1 125 ElmI. is _ TOTAL WATTS 26 18 _aa I 105 MillImo! r, .__ 2 64 IMPERIAL 45213 24" X 24" TILE TOTAL: 7,252 WAT1 PROPOSED CPT -1 ACCENT CARPET MOHAWK GROUP COLORBEAT GT160 575 INDIGO BATIK 24" X 24" TILE INSTALLATION METHOD: TBD PROVIDE SAMPLE SUBMITTAL CPT -2 VINYL COMPOSITE TILE ARMSTRONG IMPERIAL TEXTURE STANDARD EXCELON CLASSIC WHITE 51911 12" X 12" TILE PROVIDE SAMPLE SUBMITTAL mmi 0 GENERAL PAINT GLIDDEN PROFESSIONAL I" KITTEN WHITE A1772 NA mum 0 ACCENT PAINT GLIDDEN PROFESSIONAL ramirmi FOSSIL GREY A1836 MMIMrM=a PROVIDE MIN. (3) DRAW DOWNS 0 ACCENT PAINT GLIDDEN PROFESSIONAL aril PADDLEWHEEL GREY A1962 NA PROVIDE MIN. (3) DRAW DOWNS RUBBER BASE _ t- COVED TBD 4" PROVIDE SAMPLE SUBMITTAL cul _ „ I® :. 134 I� t '®`"' 123 1 ' € --iI � I I :.t 1 % �1I . a € € _atp, 130 1 I 135. WIN \ _!�: € .M. 1 136 137 100 115 113 —1 112 111 H 108 H 107 —1 106 H 105 REFLECTED CEILING PLAN 1/8" =1'-0" 0 5' 10' 20' 30' NORTH 0 FINISH PLAN 1/8"=1'-0" 5' 10' 20' 30' CEILING LEGEND NOTE: ALL EXISTING 2'X2' AND 2'X4' RECESSED LIGHT FIXTURES TO BE REMOVED TO BE REPLACED WITH NEW BIS DIRECT/INDIRECT FIXTURES. 1 EXISTING CEILING GRID AND TILES TO REMAIN. EXISTING HARD LID CEILING TO REMAIN. NEW BIS 2'X2' AND 2'X4' RECESSED FLUORESCENT DIRECT/INDIRECT LIGHT FIXTURES. (COORDINATE SPEC WITH BUILDING) z o(N) 9(N) NEW BIS 2'X2' AND 2'X4' RECESSED FLUORESCENT DIRECT/INDIRECT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY. BIS RECESSED FLUORESCENT DOWNLIGHT. (N = NEW OR RELOCATED) BIS RECESSED FLUORESCENT WALL WASHER. (N = NEW OR RELOCATED) BIS ILLUMINATED EXIT SIGN (DIRECTIONAL WHERE SHOWN). (N = NEW OR RELOCATED) BIS LIGHT SWITCH. (3 = THREE WAY, M = SUITE MASTER, D = DIMMER, N = NEW) REFLECTED CEILING KEYNOTES OPROVIDE AND INSTALL CEILING MOUNT BRACKET FOR TENANT PROVIDED PROJECTOR. COORDINATE LOCATION AND POWER/DATA REQUIREMENTS IN CELING WITH TENANT. OCONTRACTOR TO VERIFY THAT EXISTING RECESSED CAN FIXTURES ARE IN GOOD WORKING ORDER. FINISH NOTES 1. ALL WALLS TO RECEIVE , U.N.O. 2. ALL DOORS AND DOOR FRAMES TO RECEIVE 3. ALL ROOMS TO RECEIVE CPT -1 , U.N.O. ,U.N.O. 4. BASE B-1 TO BE USED THROUGHOUT, U.N.O. 5. PROVIDE (3) SAMPLES OF EVERY FINISH ITEM TO MSA FOR APPROVAL PRIOR TO INSTALLATION. 6. PROVIDE ROPPE "TILE/CARPET JOINER #50" IN COLOR (TBD - TO MATCH B-1) AT ALL CARPET TO VCT FLOORING TRANSITIONS. CEILING NOTES 1. CHECK FOR CONFLICTS BEFORE INSTALLING OR RELOCATING LIGHT FIXTURES. NOTIFY MSA OF ANY CONFLICT(S). 2. REPLACE DAMAGED CEILING TILES AND GRID AS NECESSARY TO BRING CEILING TO "LIKE NEW" CONDITION. 3. MAINTAIN EXISTING ONE FOOTCANDLE PER SQUARE FOOT AT EGRESS PATHWAY LIGHTING. 4. MAINTAIN 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF ANY V.A.V. BOXES. 5. DAYLIGHT ZONE CONTROL: DAY LIGHTING AS DEFINED BY CODE SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS PER SECTION 1513.3 OF THE WASHINGTON STATE ENERGY CODE. 6. FIRE SPRINKLERS BY OTHERS UNDER DEFERRED SUBMITTALS. 7. COMMISSIONING REQUIREMENTS: TEST LIGHTING CONTROLS TO ENSURE THAT THE SYSTEMS COMPLY*ITH CODES. PROVIDE A WRITTEN REPORT OF TEST PROCEDURES AND RESULTS TO THE OWNER. SWEEP CONTROLLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS REQUIRED. 8. EXIT SIGNS ARE INDICATED ON THE REFLECTED CEILING PLAN. THEIR PLACEMENT IS BASED UPON EXISTING CONDITION SURVEY. FINAL NUMBER OF SIGNS, THEIR PLACEMENT AND ARROW DIRECTIONS SHALL BE FIELD VERIFIED WITH THE BUILDING OFFICIAL, CONTRACTOR AND ARCHITECT. LIGHTING CALCULATION GRID CEILING @ 8'-3" A.F.F. O WATTS/FIXTURE # OF FIXTURES TOTAL WATTS 26 18 468 64 105 6,720 32 2 64 IMPERIAL 45213 24" X 24" TILE TOTAL: 7,252 WAT1 PROPOSED 8,601 TOTAL SF x 0.9 WATTS PER SF = 7,741 ALLOWABLE WATTS. TOTAL PROPOSED WATTAGE IS 7,252 - WHICH IS LESS THAN THE ALLOWABLE WATTAGE PER 2012 WSEC INTERIOR LIGHTING POWER C405.5.2 (TABLE C405.5.2(1)). FINISH KEYNOTES OEXISTING VCT FLOORING IN WORKROOM TO REMAIN. CONTRACTOR TO CLEAN AND RESEAL TO BRING TO "LIKE NEW" CONDITION. FINISH SCHEDULE SYMBOUNO. DESCRIPTION MANUFACTURER STYLE COLOR / FINISH SIZE NOTES GENERAL CARPET TANDUS ACCENTUATE 04255 IMPERIAL 45213 24" X 24" TILE INSTALLATION METHOD: TBD PROVIDE SAMPLE SUBMITTAL CPT -1 ACCENT CARPET MOHAWK GROUP COLORBEAT GT160 575 INDIGO BATIK 24" X 24" TILE INSTALLATION METHOD: TBD PROVIDE SAMPLE SUBMITTAL CPT -2 VINYL COMPOSITE TILE ARMSTRONG IMPERIAL TEXTURE STANDARD EXCELON CLASSIC WHITE 51911 12" X 12" TILE PROVIDE SAMPLE SUBMITTAL VCT -1 0 GENERAL PAINT GLIDDEN PROFESSIONAL EGGSHELL FINISH KITTEN WHITE A1772 NA PROVIDE MIN. (3) DRAW DOWNS 0 ACCENT PAINT GLIDDEN PROFESSIONAL EGGSHELL FINISH FOSSIL GREY A1836 NA PROVIDE MIN. (3) DRAW DOWNS 0 ACCENT PAINT GLIDDEN PROFESSIONAL EGGSHELL FINISH PADDLEWHEEL GREY A1962 NA PROVIDE MIN. (3) DRAW DOWNS RUBBER BASE TBD COVED TBD 4" PROVIDE SAMPLE SUBMITTAL cul S REVIEiNED FO ..ODE COMPLIAN 4 pDpOVED NOV 2 7 2013 Tukwila `)IVIStO SOUTHCENTER CORPORATE SQUARE BUILDING 3 tO3H? RECEIVED CITY OF TUKWILA NOV 12 2013 PERMIT CENTER 575 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 1500 WESTLAKE AVE N SUITE ONE, SEATTLE WA, 98109 (206) 441-1449 DRAWN BY: JK CHECKED BY: LD JOB NO.: 99135.092 NO. REVISIONS INDICATED THUS n DATE BY PERMIT SET ISSUED FOR REVIEW PERMIT SET 10/22/13 10/24/13 JK JK TENANT: WASHINGTON STATE NURSES ASSOCIATION (FIRST FLOOR REMODEL) SHEET TITLE: REFLECTED CEILING PLAN, FINISH PLAN AND FINISH SCHEDULE REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2013. TI -3 OF SOUTHCENTER CORPORATE SQUARE