Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D13-0348 - FUEGO - TENANT IMPROVEMENT
FUEGO 812 SOUTHCENTER MALL D13-0348 Parcel No: Address: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 9202470010 812 SOUTHCENTER MALL Project Name: FUEGO Permit Number: D13-0348 Issue Date: 1/3/2014 Permit Expires On: 7/2/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 KEITH SMITH 1725 WESTLAKE AVE N, SUITE 21, SEATTLE, WA, 98109 GATEWAY CONSTRUCTION SRVCS INC 5602 2ND AVE S , SEATTLE, WA, 98108 GATEWCS992C3 Lender: Name: SELF FUNDED - FUEGO Address: Phone: (206) 713-4076 Phone: (206) 621-9111 Expiration Date: 3/4/2014 DESCRIPTION OF WORK: NEW TENANT: TENANT IMPROVEMENT TO SPACE 236. MINOR DEMOLITION , MINOR NEW WALLS, NEW LIGHTS, STOREFRONT AND SIGNAGE Project Valuation: $75,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Fees Collected: $2,059.61 Type of Construction: IIB Occupancy per IBC: M Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: • • Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local la s regulating construction or the performance of work. I am authorized to sign and obtain this development p r it and agr- - o the conditions attached to this permit. Signature: Print Name: �►'7 S -!„yr/�O Date: //3//, This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. • • 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 14: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 17: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 18: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 23: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 24: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 25: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) • • 26: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 27: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 28: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2328. (ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 30: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 31: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 33: Post address on storefront per approved Westfield standards. 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH & GYPSUM 0406 SUSPENDED CEILING OLA CITY OF TUK Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building P• ermit No. 161 3-0 34 Project No. Date Application Accepted: Date Application Expires: 3-43-11 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: (/79t1yfl7e/- //a Tenant Name: UPI' (7 King Co Assessor's Tax No.: ISuite Number: PROPERTY OWNER Name: /,t /�� — (t( V/V bio Address: 2, 3 f7,i c 4y /w'j City: 1 7// toilStateO V/ ?:WA_ CONTACT PERSON — person receiving all project communication Name:rid-kk`,nj ,j� Address: ( -70)_A-In $ /; f A/{ "jt/o City: 5m� State: / J - Zip 14 / c Phone`% » 1(5 c(--7 k ir�/`� 07�L /aux Email: .._.S/44. �� 6.747/1 (w s'C/ m ov GENERAL CONTRACTOR INFORMATION Company Name: 1 Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-I2.docx Revised: February 2012 Floor: New Tenant: ,K Yes .. No ARCHITECT OF RE //�, ,C�IO�RD Company Name: G l /�t'.1 < 0 1/(_, , Architect Name: ..e (A,..1 s L j/ Address: /7 w�,f��a �jn /tie� 'e ,��1 City: �- State:/�Zip: ?/ Phone:' (; j 3 Fax: r win ood 7 Email: kj :I14`1 sm ti4ii,J c0f1 ENGINEER OF RECORD i Name: VP) 0 e" el w I �� MA Address: Company Name: !/ l Zip: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) i Name: VP) 0 e" el w I �� MA Address: ` /iA1ia1 % /- J(�State: City: Zip: Page 1 of 4 BUILDING PERMIT INFORMAT• — 206-431-3670 • Valuation of Project (contractor's bid price): $ �5 ) /.v Existing Building Valuation: $ Describe the scope of work (please provide detailed information): 7-e/ 4i1— (Wi p/ 1%eyi ' '01 )3 kol/ den4dirlarlt t1011/1tIl ktebt/ Wal/51 .6142 tOk Will there be new rack storage? ❑ ....Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 14,1 Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor /( O/ ///3 iti 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 14,1 Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES -• • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 1 WNER OR THORIZED AGENT: Signature: Print Name: 1 L4 411 & MA Ai t. Mailing Address: 4\0 H:Wpplications\Forms-Applications On Line\2012 Applications'.Fermit Application Revised - 2-7-12.docx Revised: February 2012 bh Date: 1 5 Day Telephone: o /) / 13 act_C y 2'1'4 State Zip Page 4 of 4 PUBLIC WORKS PERMIT IN TION — 206-433-0179 • Scope of Work (please provide detailed information): l/1 - Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ,Tukwila 0 ...Water District #125 ❑... Highline 0 .. Water Availability Provided Sewer District =Tukwila 0 ...Valley View ❑ ... Renton Sewer Use Certificate 0 ...Sewer Availability Provided 0... Renton 0... Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance 0... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water 0... Geotechnical Report 0...Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) ❑ ... Right-of-way Use - Profit for less than 72 hours 0...Right-of-way Use — Potential Disturbance 0...Work in Flood Zone O... Storm Drainage 0... Abandon Septic Tank ❑...Curb Cut 0... Pavement Cut 0...Looped Fire Line ❑...Grease Interceptor ❑... Channelization 0...Trench Excavation 0...Utility Undergrounding ❑ .. Permanent Water Meter Size (1) " WO # (2) " WO # (3) " WO # ❑ .. Temporary Water Meter Size (1) " WO # (2) " WO # (3) " WO # ❑ .. Water Only Meter Size WO # 0 .. Deduct Water Meter Size " ❑ .. Sewer Main Extension Public 0 Private 0 ❑ .. Water Main Extension Public 0 Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 .. Water 0 .. Sewer 0 .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Apphcations\Forms-Applications On Line \2012 Applications\Permit Application Revisal - 2-7-12.docx Revised: February 2012 w�. Page 3 of 4 Cash Register Receipt • City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,248.25' D13-0348 Address: 812 SOUTHCENTER MALL Apn:9202470010 $1,248.25 DEVELOPMENT PERMIT FEE TOTAL FEES PAID BY RECEIPT: R570 R000.322.100.00.00 $1,248.25 $1,248.25 $1,248.25 Date Paid: Friday, January 03, 2014 Paid By: GATEWAY CONSTRUCTION SRVCS INC Pay Method: CHECK 45998 Printed: Friday, January 03, 2014 10:50 AM 1 of 1 ?SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $811.36 D13-0348 Address: 812 SOUTHCENTER MALL Apn: 9202470010 $811.36 DEVELOPMENT $811.36 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R94 R000.345.830.00.00 $811.36 $811.36 Date Paid: Wednesday, November 13, 2013 Paid By: KEITH SMITH Pay Method: CREDIT CARD 013330 Printed: Wednesday, November 13, 2013 1:14 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF.TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: kf."--&D Typepf Inspection: N` l5t9 t tO 1 j Address Date Called: Special Instructions: Date Wanted:a — �l�, m p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Axip (e)re Ins Date: v ,l4 n REINSPECTION, FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Calh,ta schedule reinspection. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 INSPECTION RECORD Retain a copy with permit. 3-6 PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit.lnspection Request Line (206) 431-2451 Proje Type of Inspection: 1 Addre c MAW Date Called: a- a. L.c . )'.�- Special Instructions: / Date Wanted: a.m. P.m. Requester: % Phone No: Approved per applicable codes. Corrections requiredprior to approval. COMMENTS: At AV6 Inspector:. Date: 1 e' 1 t n REINSPECTION FEE,REQUIItED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection: INSPECTION RECORD Retain a .copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Di 3 -0318 Project' - Type of -Inspection: Address: Date Called: Special Instructions: Date Wanted: 369..11 r a.m. Requester: Phone No: ElApproved per applicable codes. !__ ] Corrections required prior to approval. COMMENTS: DV--�?J 2J t J r __I0rR�Q --h lnsp tor: Date: t —3 J_ t1 n REINSPECTION -FEE EQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 7)13- 031?) /y P- 401 a. PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: ,-- -} lx 2q O Sprinklers: TyRt, of Insp n ction: --int- -R/ — c ro �li Address: q ) D' Suite #: 5. C.. rvi+-ti-- Contact P rson: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: O Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Date: 3/h5 /11/ Hrs.: Inspector:� S $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit 7)13-0�� .I—S— ooK-- INSPECTION NUMBER PERMIT NUMBERS •CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila,, Wa. 98188, 206-575-4407 Project: Sprinklers: Type pf Inspection: Address: ') Suite #: C 12. S'C vWk( Contact Person: Special Instructions: Occupancy Type: - Phone No.: 4S, Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1\A c-cpcgol- .1e)e)vvv_ tk.trc 47 -A -c‹, /71,*mAert--v Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: - Inspector: 4' -- Date: 2 -7/ _:ir Hrs.: I v i $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address TO, Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 7)13-G1Vg PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188; 206-575-4407 Project: ,— 3-2Aza 1 Sprinklers: • Type of Inspection: ", • 41 Address: (2_ Suite #: 5c to kl ( Contact Person: l Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS:. Sprinklers: • Fire Alarm: r Monitor: Pre -Fire: Permits: Occupancy Type: ../7/1( 0/Z JA-/ Ga ->I(, .,tce — /Yea ---- %- f � l c o fr; . t Q //�i- /fL/j / ARAI-� /Q/_1 / s D y� Ai€,',l U-%1,�" - 4l41/4 Sill "0,7 Gam/ A e S .4'.f,t-7 Gl'`, Needs Shift Inspection: Sprinklers: • Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:',, yam Date: 2/7// 1` Hrs.: / /4' $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Di 3 - c>3NL /L/- S-oos— PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Sprinklers: z Type o nspection: Hood & Duct: Address: 1 D._S.C.. Suite #: ° Monitor: 1't/l41.l-- Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. IKC2frections required prior to approval. COMMENTS: Sprinklers: z Fire Alarm: Hood & Duct: Hrs.: Monitor: Pre -Fire: ' Permits: Occupancy Type: CY (loo-er )47 '�/k,ti, P/se__, Needs Shift Inspection: Sprinklers: z Fire Alarm: Hood & Duct: Hrs.: Monitor: Pre -Fire: ' Permits: Occupancy Type: Inspector: ^ z cl Date: //3(/ / c-/ Hrs.: I 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • PERMIT CORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-0348 DATE: 11-13-13 PROJECT NAME: FUEGO SITE ADDRESS: 812 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Buil Ing :v/i4 n Public Woksti"(1 Structural Fire Prevention ❑ N /4— Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-14-13 Complete ri Incomplete n Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 1-$ Structural Review Required n No further Review Required Ti REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 12-12-13 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 GATEWAY CONSTRUCTION SRoS INC (IlWashington State Department of k'Labor & Industries • Page 1 of 2 GATEWAY CONSTRUCTION SRVCS INC Owner or tradesperson SACCO, RONALD Principals SACCO, RONALD CRISTIAN NIELSEN Doing business as GATEWAY CONSTRUCTION SRVCS INC WA UBI No. 602 086 011 5602 2nd Ave. S. SEATTLE, WA98108 206-621-9111 KING, County Business type Corporation Governing persons CHARLESJPORTER License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. GATEWCS992C3 Effective — expiration 02/26/2001 — 03/04/2014 Bond TRAVELERS CAS & SURETY CO Bond account no. 105165492 $12,000.00 Received by L&I Effective date 08/21/2008 08/19/2008 Insurance Travelers Indemnity Company Th Policy no. DTC0527D0333IND12 $1,000,000.00 Received by L&I Effective date 07/24/2013 08/01/2012 Expiration date 08/01/2014 Savings No savings accounts during the previous 6 year period. httns://secure.lni.wa.gov/verify/Detail.aspx?UBI=602086011&LIC=GATEWCS992C3&SAW= 01/03/2014 PROJECT GENERAL NOTES PROJECT DATA fiJ SPACE 236 812 SOUTHCENTER MALL, TUKWILA, WA 98188 PROJECT DIRECTORY LANDLORD NOTES 1. SEE APPROPRIATE DRAWINGS FOR GENERAL NOTES OF OTHER DISCIPLINES: STRUCTURAL, ELECTRICAL, MECHANICAL AND PLUMBING. 2. DO NOT SCALE DRAWINGS- USE DIMENSIONS ONLY. 3. DIMENSIONS WHERE SHOWN ARE NORMALLY GIVEN: A. TO COLUMN CENTER LINE B. TO FINISH FACE OF CMU OR GWB. 4. DIMENSIONS SHOWN ON LARGER SCALE DRAWINGS GOVERN. 5. FIELD VERIFY ALL EXISTING CONDITIONS. REVIEW EXISTING CONDITIONS PRIOR TO COMMENCING THE WORK, NOTIFY ARCHITECT OF UNEXPECTED CONDITIONS. 6. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB, UNLESS NOTED OTHERWISE. 7. "ALIGN" AS INDICATED ON THE DRAWING SHALL BE UNDERSTOOD TO MEAN TO ALIGN THE FINISH MATERIAL OF THE WALLS OR COLUMNS INDICATED. 8. ALL INTERIOR GYPSUM WALL BOARD IS 5/8 " TYPE X GWB ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON PLANS. SEE NOTE FOR LOCATION OF WATER RESISTANT GWB. 9. PROVIDE WATER RESISTANT TYPE X GWB IN ALL TOILET ROOMS, WAREWASH AND WET AREAS. 10. ALL FINISH CEILING HEIGHTS SHALL BE CONFIRMED UNLESS NOTED OTHERWISE ON THE ROOM FINISH SCHEDULE. 11. PROVIDE FINISH WALL BEHIND ALL EQUIPMENT AND CASEWORK. 12. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION. 13. PROVIDE ONE TYPE 5E-2A-10BC FIRE EXTINGUISHER PER 3,000 SF AND NOT MORE THAN 75 FT OF TRAVEL DISTANCE. 14. THERE SHALL BE NO BACK-TO-BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT NONRATED, PARTITIONS. SEPARATE OUTLETS BY 24" MIN. AT FIRE RATED PARTITIONS. 15. WHERE HVAC OR OTHER MECHANICAL ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE AND/OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. 16. ALL CHANGES IN PROJECT SCOPE DUE TO CONTRACTOR GENERATED ALTERNATES OR EXISTING FIELD CONDITIONS SHALL BE TRANSMITTED TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 17. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING AND INSTALLING OF OWNER FURNISHED ITEMS LISTED, UNO. 18. PROVIDE EXIT ILLUMINATION PER LOCAL CODES. 19. MODIFY THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS. COMPLY WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS. 20. SPRINKLER HEADS MOUNTED IN HARD (GWB) CEILINGS TO BE FULLY RECESSED WITH WHITE CAPS. 21. INSTALL ALL COMPONENTS OF FIRE RATED ASSEMBLIES PER RATING CRITERIA. 22. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED. 23. FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS. 24. PROVIDE FINISH FLOOR UNDER ALL EQUIPMENT AND CASEWORK. FOR ADDITIONAL ABBREVIATIONS SEE OTHER DESIGN DISCIPLINES ACOUS. ADJ A.F.F. ALUM ANOD. APPROX. BD. B.F.F. BLDG. BLK. BLK'G. BM. BOT. BTWN. CB C.G. C.I. C.I.P. C.L. CLR. CLG. CMU COL. CONC. CONT. CONSTR. CONTR. C.T. DBL DIM. DTL. D.F. D.S. DWG. EA. E.F.S. E.I.F.S. ACOUSTICAL ADJUSTABLE, ADJACENT ABOVE FINISHED FLOOR (SLAB) ALUMINUM ANODIZED APPROXIMATE BOARD BELOW FINISHED FLOOR (SLAB) BUILDING BLOCK BLOCKING BEAM BOTTOM BETWEEN CATCH BASIN CORNER GUARD CAST IRON CAST IN PLACE CENTER LINE CLEAR CEILING CONCRETE MASONRY UNIT COLUMN CONCRETE CONTINUOUS CONSTRUCTION CONTRACTOR CERAMIC TILE DOUBLE DIMENSION DETAIL DRINKING FOUNTAIN DOWNSPOUT DRAWING EACH EXTERIOR FINISH SYSTEM EXTERIOR INSULATION AND FINISH SYSTEM ELEV. ELEC. ENCL. EQ. EXH. EXIST. EXP. EXT. F.D. FDN. FF FHS FL. F.I.O. FIN. F.R.P.P. PANEL(S) FRT. FTG. GA. GALV. G.C. GWB H.B. H.C. H.M. HORIZ. H.P. HT. HTR. HVAC IBC INSUL. INT. JT./JTS. ADDRESS: CONSTRUCTION TYPE OCCUPANCY GROUP APPLICABLE CODES: NUMBER OF EMPLOYEES OCCUPANCY SQ. FOOTAGE TOTAL OCCUPANT LOAD PROPOSE USE: TOILETS: 2800 SOUTHCENTER MALL TUKWILA, WA 98188-2888 EXISTING/ NEW CONSTRUCTION TYPE: TYPE II -B UNPROTECTED NONCOMBUSTIBLE PRIMARY OCCUPANCY: M-MERCHANTILE INCIDENTAL OCCUPANCY: GROUP S1 2012 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS 2012 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE AMENDMENTS 2012 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS 2012 NATIONAL ELECTRIC CODE WITH WASHINGTON STATE AMENDMENTS CHAPER 11 IBC AND OTHER INTERNATIONAL BUILDING CODE REQUIREMENTS FOR BARRIER - FREE DESIGN INCLUDING ICC/ANSI A117.1 - 2009 2012 WASHINGTON NON RESIDENTIAL ENERGY CODE 2012 NATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS ALL LOCAL ORDINANCES HAVING JURISDICTION NA 1,107 SQ. FT. S1 - STOCK 76 SF/300= 1 M - SALES 1031 SF/30 = 35 36 MERCHANTILE- RETAIL PROVIDED BY MALL COMMON TOILETS SEPARATE SUBMITTALS MEP, FIRE ALARM AND SIGNAGE UNDER SEPARATE SUBMITTAL. SCOPE OF WORK BUILDING: THE WORK INCLUDES, BUT NOT LIMITED TO INTERIOR TENANT IMPROVEMENTS AND FINISHES, ITEMS FURNISHED BY THE OWNER AND INSTALLED BY THE CONTRACTOR AND ITEMS FURNISHED AND INSTALLED BY THE OWNER WITH FINAL CONNECTIONS BY THE CONTRACTOR. THE WORK ALSO INCLUDES, BUT NOT LIMITED TO, INTERIOR AND STOREFRONT SIGNAGE, HVAC SYSTEMS, ENERGY MANAGEMENT SYSTEMS, PLUMBING AND ELECTRICAL/LIGHTING SYSTEMS. ON SITE: NO WORK ARCHITECTURAL ABBREVIATIONS ELEVATION ELECTRICAL ENCLOSURE EQUAL EXHAUST EXISTING EXPANSION EXTERIOR FLOOR DRAIN FOUNDATION FACTORY FINISH FLAT HEAD SCREW FLOOR FURNISHED AND INSTALLED BY OWNER FINISH FIBER REINFORCED PLASTIC FIRE RETARDANT TREATED FOOTING GAUGE GALVANIZED GENERAL CONTRACTOR GYPSUM WALLBOARD, GYPSUM BOARD HOSE BIBB HANDICAPPED HOLLOW METAL HORIZONTAL HIGH POINT HEIGHT HEATER HEATING, VENTILATION, AND AIR CONDITIONING INTERNATIONAL BUILDING CODE INSULATION INTERIOR JOINT, JOINTS L. LAM. L.F. LIQ. L.P. LT.WT. MAS. MAX. M.B.S. MECH. MFG. MFR. M.H. MIN. M.I.P. MISC. M.O. M.R. MULL. MTD. MTG. MTL. N.I.C. NOM. N.T.S. O.A. O.C. O.D. O.H. OP'G OPP. PTN. PERP. LONG, LENGTH LAMINATE, LAMINATED LINEAR FOOT, LINEAL FOOT LIQUID LOW POINT LIGHT WEIGHT MASONRY MAXIMUM METAL BUILDING SUPPLIER MECHANICAL MANUFACTURING MANUFACTURER MANHOLE MINIMUM METAL INSULATTED PANEL MISCELLANEOUS MASONRY OPENING MOISTURE RESISTANT MULLION MOUNTED MOUNTING METAL NOT IN CONTRACT NOMINAL NOT TO SCALE OVERALL ON CENTER OVERFLOW DRAIN OVERHEAD OPENING OPPOSITE PARTITION PERPENDICULAR PL. PLATE, PROPERTY LINE PLAS.LAM. PLASTIC LAMINATE PLYWD. PLYWOOD PLBG. PLUMBING PNL. PANEL, PANELING .' PR. PROJ. PRV P.T. Q.T. QTR. R R.C. R.C.P. R.D. R.L. REC'D. REFRIG. REINF. REQ'D. R.O. SCHED. S.C. SHT. SIM. S.I.O. S.I.V. S.O.I.C. SQ. S.S. SST STD. STL. STRUCT. SUSP. SYS. T T.O.J. T.O.M. T.O.P. PAIR PROJECT PRESSURE REDUCING VALVE PRESSURE TREATED QUARRY TILE QUARTER RADIUS REFRIGERATION CONTRACTOR REFLECTED CEILING PLAN ROOF DRAIN ROOF LEADER RECEIVED REFRIGERATION REINFORCING REQUIRED ROUGH OPENING SCHEDULE SOLID CORE SHEET SIMILAR SUPPLIED AND INSTALLED BY OWNER SUPPLIED AND INSTALLED BY VENDOR SUPPLIED BY OWNER INSTALLED BY CONTRACTOR SQUARE SERVICE SINK, SANITARY SEWER STAINLESS STEEL STANDARD STEEL STRUCTURE, STRUCTURAL SUSPENDED SYSTEM TREAD, TOP TOP OF JOIST TOP OF MASONRY TOP OF PARAPET ARCHITECT: smith co. LLC 1725 westlake avenue n. suite 210 Seattle, WA 98109 t: 206.383.54850 f: 206.464.0700 PROJECT MANAGER: Keith Smith TENANT WESTFIELD CORPORATION COORDINATION TENANT COORDINATION - SOUTHCENTER 14TH FLOOR, 1161 WILSHIRE BLVD. LOS ANGELES, CA 90025 (310) 478-4456 T (310) 575-5991 F Josh Kimmel (310.893.4761 MALL WESTFIELD SOUTHCENTER MANAGEMENT 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188-2888 (206) 246-0423 T REVISIONS No changes shall be made to the, scope of work without prior approval of Tukwila Building Division. F'!OTE: Revisions will require a new plan submittal and may include additional plan review fees. T.O.S. T.O.W. T&B TEL. TEMP. TYP. UTIL. U.B.C. U.N.O. V.C.T. VERT. V.I.F. W/ W/O WD. WDW. WHS. W.P. W.R. WT. W.W.F. Y.D. TOP OF STEEL TOP OF WALL TOP AND BOTTOM TELEPHONE TEMPERED GLASS TYPICAL UTILITY UNIFORM BUILDING CODE UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL VERIFY IN FIELD WITH WITHOUT WOOD WINDOW WELDED HEAD STUD WATERPROOF WATER RESISTANT WEIGHT WELDED WIRE FABRIC YARD DRAIN SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing ►'4 Gas Piping City of Tukwila WING DIVISION DRAWING INDEX 1. ILLUMINATED SIGNAGE SHOULD BE CONTROLLED BY TIME CLOCK, LIGHT LEAKS FROM CASEWORK NOT PERMITTED. LANDLORD MUST APPROVE, IN WRITING, ALL PROPOSED SIGNAGE PRIOR TO INSTALLATION. 2. ALL CABLING AND WIRES TO BE CONCEALED. AUDIO WILL NOT BE PERMITTED. 3. SNEEZE GUARDS TO BE BUTT JOINTED, FRAMELESS, NO VERTICAL SUPPORTS WITH SQUARE EDGE DETAIL /UV BONDING 4. ALL LIGHTING REQUIREMENT TO BE INSTALLED WITHIN FLOATING RETAIL. LIGHTING TO BE SURFACE MOUNTED TO COUNTER DURING FABRICATION. 5. TENANT MUST INSTALL LANDLORD APPROVED LATEX -RUBBER WATERPROOFING MATERIAL UNDER THE FLOOR FINISH. THE MEMBRANE MUST LAP UP PERIMETER WALLS UNDERNEATH THE COVED BASE TO MIN. HT. OF 12"AFF. AND UNDER THE COVED BASE OF THE DISPLAY CABINETRY INSIDE OF THE RETAIL SPACE. 6. ALL MECHANICAL & PLUMBING SYSTEMS AND EQUIPMENT SHALL BE INSTALLED, BRACED AND INSULATED IN ACCORDANCE WITH ALL LOCAL CODE REQUIREMENTS. TENANT SHALL MAKE ALL CONNECTIONS TO THE UTILITY SERVICES PROVIDED. 7. FOR FOOD COURT TENANTS, THE DOMESTIC WATER SERVICE SHALL BE 2". TENANTS WITH HIGH WATER USAGE SHALL PROVIDE AND INSTALL A DOMESTIC WATER SUB -METER. TENANTS SHALL PROVIDE AND INSTALL A REDUCED PRESSURE BACKFLOW PREVENTER ON THEIR WATER SERVICE. WATER PIPING SHALL BE TYPE 'L' HARD COPPER TUBE ABOVE GRADE AND TYPE 'K' SOFT COPPER TUBE BELOW GRADE. WATER HEATERS SHALL BE ELECTRIC. 8. FOR FOOD RELATED TENANTS, GAS SERVICE IS AVAILABLE. TENANTS ARE REQUIRED TO INSTALL AN EARTHQUAKE VALVE. 9. TENANT SHALL DESIGN AND INSTALL AN ELECTRICAL /TELEPHONE BASED ON THE FOLLOWING: A 277 / 488 VOLT , THREE-PHASE, FOUR WIRE, 60 CYCLE SYSTEM. CONDUIT PROVISIONS FOR FLOATING FOOD KIOSKS: 200A (208Y / 120V) -(2) 3" CONDUIT. ELECTRICAL SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH LANDLORDS CRITERIA AS OUTLINED IN THE DESIGN MANUAL. 10. TENANTS CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER. ARCHITECTURAL T-1 GENERAL INFORMATION D-1 DEMOLITION PLAN A-1 CONSTRUCTION PLAN A-1.1 FIXTURE PLAN A-2 FLOOR FINISH PLAN A-3 REFLECTED CEILING PLAN A-4 STOREFRONT ELEVATIONS A-5 DETAILS REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013^ t,Vnv/ City of(T iIa BUILDING\ VISION SHEET A-3 The path of egress shall show sufficient illumination of 1 foot-candle at the walking surface leading to the exit discharge doorways SITE PLAN VICINITY MAP SYMBOLS DETAIL l j FUTURE RETAIL DETAIL IDENTIFICATION CUT LINE - DEFINES THE DETAILED ELEMENT SHEET WHERE DRAWN WALL SECTION DETAIL IDENTIFICATION CUT LINE - DEFINES THE DETAILED ELEMENT _SHEET WHERE DRAWN BUILDING SECTION DETAIL IDENTIFICATION SHEET WHERE DRAWN EXTERIOR ELEVATION DETAIL IDENTIFICATION SHEET WHERE DRAWN INTERIOR ELEVATION DETAIL IDENTIFICATION SHEET WHERE DRAWN 9 CPenney PROJECT LOCATION Space 236 AIM SCALE: N.T.S. ARCHITECTURAL SYMBOLS NORTH ARROW PROJECT NORTH ARROW TRUE NORTH INDICATOR DOOR MARK DOOR CODE - REFER TO SCHEDULE WINDOW, RELITE OR LOUVER MARK WINDOW NUMBER - REFER TO SCHEDULE EQUIPMENT MARK EQUIPMENT K24 NUMBER - REFER TO SCHEDULE ROOM MARK ROOM --ROOM NAME 100 ROOM NUMBER COLUMN GRIDS 50'-0" A.F.F. SLOPE DOWN 1/8" PER FOOT REVISION CLOUD AND DELTA WORK, CONTROL OR DATUM POINT SLOPE DIRECTION WITH DATUM MARK f SPRINKLER MAIN PROPERTY LINE 1111 1=21 FENCE x x x x x x x \\ BREAKLINE WALL TYPE MARK WALL TYPE NOTE PROJECT SITE MS 3AV 31VOS3NVC ITEM S.I.O OR N.I.C. ITEM S.O.I.0 OR S.I.C. NEW CONSTRUCTION - SHOWN SOLID EXISTING CONSTRUCTION TO REMAIN - SHOWN LIGHT BACKGROUND EXISTING CONSTRUCTION TO BE REMOVED - SHOWN DASHED 0 FE FIRE EXTINGUISHER MATERIALS 'I�iIiAL (/4 ITO GYPSUM BOARD CONCRETE EARTH GRAVEL CMU OR BRICK PLYWOOD RIGID INSULATION BATT INSULATION WOOD MEMBER WOOD BLOCKING FINISHED WOOD ACOUSTICAL TILE STEEL ALUMINUM E.I.F.S. SOUND INSULATION g' Lg SOUTHCENTER SHOPPING CENTER 812 Sou th cen ter Mall SPACE 236 Seattle WA 98188 smith co. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith@smithco.org http://www.smithco.org/ Consultant Consultant Registration RECEIVED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER Issues and Revisions Architect Registration 6294 STATE OF WASHINGTON No. Date Issues By Check flan review -approval is subject to errors and omissions. gnprc'fai of construction documents does not auhc:' Il • , adopted code or ordinance. Rocx 'Fitl Co�,;� co Is ledge IMP Date: City of TUkwila BUILDING DIVISION Project Name Fuego Project Number 02006088.00 Description GENERAL INFORMATION Computer File CW05-2008-T1.DWG Scale AS NOTED Template 4.3 (120101) 8 All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. IIc. T-1 LEGEND KEY SCHEDULE 0.C. 0 EXISTING DEMISING WALL TO REMAIN. PATCH AND REPAIR AS REQUIRED TO MAINTAIN EXISTING FIRE RATING. ® EXISTING COLUMN TO REMAIN, REMOVE EXISTING FINISHES TO RECEIVE NEW FINISHES, ® REMOVE EXISTING STOREFRONT ® REMOVE EXISTING WALL, U.N.O, ® REMOVE EXISTING DOORS, FRAMES AND THRESHOLDS, U,N,❑, FOR REUSE © REMOVE EXISTING FURNITURE, FIXTURES AND MILLWORK, U.N.❑, Q REMOVE EXISTING FLOOR FINISHES TO BASE BUILDING STRUCTURE, U.N.❑, PATCH AND REPAIR AS REQUIRED TO RECEIVE NEW FINISHES. ® REMOVE EXISTING LIGHT FIXTURES AND ASSOCIATED ELECTRICAL, DIFFUSERS, ETC., U.N.O. FOR REUSE ® EXISTING ELECTRICAL/PHONE PANELT❑ REMAIN 0 REMOVE EXISTING SOFFIT AND RECESSED CAN LIGHTS • DENOTES EXISTING WALL - _ _ - -: DENOTES EXISTING WALL TO BE REMOVED : DENOTES NEW 3-5//8"x20 GA. Q 24" DIETRICH METAL STUDS ICBG # 4784P LA R.R. NO. 25132 0 , SYMBOL DENOTES DOOR, SEE DOOR SCHEDULE FOR ADD'L INFO. 1. CONTRACTOR TO VERIFY ALL DIMENSIONS 2. DO NOT SCALE DRAWINGS iii LEASE LIME LEASE LINE Ij LEASE LINE r--� L_ ADJACENT TENANT 000 ADJACENT TENANT 000 J REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION L_ DEMOLITION PLAN SCALE: 1/4' = 1'4Y II \\ �/ II II 1 MALL COMMON 00 LEASE LINE MALL COMMON 00 RECEIVED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER ti n SOUTHCENTER SHOPPING CENTER 812 Sou th cen ter Mall SPACE 236 Seattle WA 98188 smith cc 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith@smithco.org http://www.smithco.org/ Consultant Consultant Registration Issues and Revisions Architect Registration 6294 STATE OF WASHINGTON No. Date Issues By Check 1 10.21.13 PERVIT KLS Project Name Fuego Project Number 0200801800 Description DEM❑LITI❑N PLAN Computer File CW05-2008—D1,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. 0-1 WALL PARTITION FINISH LEGEND ® SEE RESPONSABILITY SCHEDULE ON T1. ATTACH TO ROOM NAME DOOR SIZE DOOR MATERIAL DOOR FINISH ' GWB BY LL -I HARDWARE GROUP I- „ 6 SLOTTTED TRACK (SLP–TRK OR EQ.) ATTACH TO STRUCTURE ABOVE 2X4 SUSPENDED CEILING OR GWB co3 MATERIAL , STRUCTURE ABOVE SALES SIDE 2X4 SUSPENDED 54 CEILING OR GWB P-1 PAINT BENJAMIN MOORE BEIGE — #967 FLAT EGGSHELL 2X4 SUSPENDED CEILING OR GWB —► x 3 5/8" 20 GAGE METAL GLASS ALUM. ANOD. ALUM. © 4, 5, 6, 7 P-2 PAINT BENJAMIN MOORE METAL P-3 ryM `{ 5/8" 20 GAGE METAL STUDS AT 16"O.C. WITH ONE LAYER 5/8" GYPSUM BOARD. —L—— O ; STUDS AT 16" O.C. WITH ONE LAYER 5/8" GYPSUM BOARD. 3 5/8" 20 GAGE METAL STUDS AT 16" O.C. WITH METAL 3 5/8" 20 GAGE STUDS AT 16 O.C. WITH ONE LAYER 5/8" GYPSUM BOARD TO 6" ABOVE METAL P-2 OA ONE LAYER 5 8" GYPSUM / P-4 FINISHED CEILING.. BENJAMIN MOORE BEIGE — #967 SATIN LOW LUSTRE CORRIDOR SIDE SEE FINISH NOTES FOR FLOOR FINISH TENANT SIDE SECURE BOTTON TRACK TO CONCRETE SLAB USING POWER DRIVEN FASTENERS MIN. .145 AT 18" O.C. PAINTABLE FIRESTOP SEALANT BOTH SIDES BOARD ON ONE SIDE. RESTROOM SIDE SEE FINISH NOTES FOR FLOOR FINISH SECURE BOTTON TRACK TO CONCRETE SLAB USING POWER DRIVEN FASTENERS AT O.C, MIN. .145 STOCK ROOM SIDE STOCK ROOM SIDE SEE FINISH NOTES FOR FLOOR FINISH SECURE BOTTON TRACK TO CONCRETE SLAB USING POWER DRIVEN FASTENERS MIN. .145 AT 18° O.C. SEE FINISH NOTES FOR FLOOR FINISH NOTE: ALL STEEL STUDS AND BOTTOM ON BOTH .7 MUST BE SCREWED TOP SIDES. NOTE: ALL STEEL STUDS AND BOTTOM 47 ON BOTH MUST / BE SCREWED TOP SIDES. NOTE: ALL STEEL STUDS AND BOTTOM iii7 MUST ON BOTH BE SCREWED TOP SIDES. <>WALL PATITIO\ •WALL PATITIO\ •1HOU UL N0. U465 WALL 0-1 PATITIO\ JOHNSONITE #86 — HUNTER GREEN — SALES AND OFFICE ONLY CL -1 GYP. BD. CEILING NEW PAINTED GYP. BD. - - R,.ATTACH TO STRUCTURE ABOVE CL -2 \ 1 PAINTED 6" SLOTTTED TRACK (SLP–TRK OR EQ.) ATTACH TO I DOOR I; 6"SLOTTTED TRACK (SLP–TRK OR EQ.) ATTACH TO STRUCTURE ABOVE HOLD GWB DOWN FOR �6 2X4 SUSPENDED CEILING OR GWB TENANT SIDE w a STRUCTURE ABOVE HOLD GWB DOWN FOR VENTILATION RETURN TENANT SIDE ENTRY PUSH/PULL HARDWAREE W/ LOCKSET, CLOSER STOCK ROOM SIDE INTERIOR FINISH MATERIALS SHALL BE CLASS A OR CLASS B PER NFPA 101, 24-3.3, 1997 EDITION. BO PRIVACY LEVER HARDWARE (BRUSHED CHROME) NEW LOCK. KICK PLATES ON BOTH SIDES. . VENTILATION RETURN „ 3 5/8 20 GAGE METAL O cask 1. NEW DOOR SUPPLIED, INSTALLED AND FINISHED BY L.L.G.C. . 2. ALL NEW DOOR OPENINGS ARE NONBEARING OR NON—SHEAR WALLS. 3. SERVICE DOOR BUZZER WITH BUZZER STATIONS ABOVE CEILING AT CASHWRAP AND OFFICE. 4. EXIT DOORS SHALL NOT BE SUBJECT TO THE USE OF A KEY OR REQUIRE SPECIAL KNOWLEDGE TO OPERATE PER 2006 IBC 5. INSTALL WALL DOOR STOPS AT HEIGHT OF DOOR KNOB AT ALL DOORS THAT SWING INTO OR OUT TOWARD A WALL. 6. INSTALL DOOR SILENCERS. 7. NOT USED 8. SALES TO CORRIDOR DOOR TO HAVE A DORMA DOOR CLOSER WITH MODEL #DC—DSTHO "HOLD OPEN ARM" 9. L.L.G.C. TO INSTALL A WIDE ANGEL PEEP HOLE. ANY DOOR NOT CONFORMING TO THIS PLAN OR CODE SHALL BE UPGRADED AS REQUIRED PER ALL CODES. SWING AND FORCE TO OPEN DOORS SHALL MEET THE REQUIREMENTS OF THE IBC 2006 SELF CLOSING DEVICES SHALL MEET THE REQUIREMENTS OF THE IBC 2006 PANIC HARDWARE SHALL BE PROVIDED FOR ALL EXIT DOORS PER THE REQUIREMENTS OF IBC 2006 GENERAL NOTES 1. T.G.C. TO COVER WINDOWS WITH PLAIN PAPER UNTIL THE END OF CONSTRUCTION. WINDOWS MUST THEN BE CLEANED AFTER REMOVAL AND ANY TAPE ADHESIVE REMOVED. PAPER TO BE REMOVED AND WINDOWS TO BE CLEANED PRIOR TO TURNOVER 2. T.G.C. TO VERIFY DOORS IN THE MEANS OF EGRESS SYSTEM TO BE OPERABLE FROM INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 3. INTERIOR WALL AND CEILING FINISH MATERIALS IN MERCANTILE OCCUPANCIES SHALL BE CLASS A OR CLASS B PER NFPA 101, 24-3.3, 1997 EDITION. 4. T.G.C. SHALL PROVIDE SUFFICIENT NUMBER OF 2A1OBC FIRE EXTINGUISHERS SO THAT A FIRE EXTINGUISHER CAN BE REACHED WITHIN 75 FEET OF NORMAL TRAVEL FROM ANY POINT IN THE BUILDING. PLEASE TAKE INTO CONSIDERATION THAT FIRE EXTINGUISHERS SHOULD BE LOCATED NEAR EXITS. MOUNTING HEIGHT SHALL BE 4 FEET A.F.F. MAXIMUM. :,4 ‘i_._,/,___EL >. 6" 20 GAGE METAL ;STUDS AT 16" O.C. WITH ONE LAYER 5/8" GYPSUM BOARD. — 3 5/8" 20 GAGE METAL STUDS AT 16° O.C. WITH 6" 20 GAGE METAL STUDS AT 16" O.C. WITH ONE LAYER 5/8" GYPSUM BOARD. 3 5/8" 20 GAGE METAL STUDS AT 16" O.C. WITH ONE LAYER 5/8" GYPSUM BOARD. STUDS AT 16" O.C. WITH ONE LAYER 5/8" GYPSUM ONE LAYER 5/8" GYPSUM BOARD ON ONE SIDE. RESTROOM SIDE 4. SEE FINISH NOTES FOR FLOOR FINISH TENANT SIDE SECURE BOTTON TRACK TO CONCRETE SLAB USING POWER DRIVEN FASTENERS MIN. .145 AT 18 O.C. PAINTABLE FIRESTOP SEALANT BOTH SIDES SEE FINISH NOTES FOR FLOOR FINISH SECURE BOTTON TRACK TO CONCRETE SLAB USING POWER DRIVEN FASTENERS MIN. .145 AT 18" O.C. PAINTABLE FIRESTOP SEALANT BOTH SIDES BOARD ON ONE SIDE, CORRIDOR SIDEUSING SEE FINISH NOTES FOR FLOOR FINISH SECURE BOTTON TRACK TO CONCRETE SLAB POWER DRIVEN FASTENERS MIN. .145 AT 18" O.C. PAINTABLE FIRESTOP SEALANT BOTH 1 S �i %�/ / NOTE: ALL STEEL STUDS MUST BE SCREWED TOP AND BOTTOM ON BOTH SIDES. /r ',�/ / NOTE: ALL STEEL STUDS MUST BE SCREWED TOP AND BOTTOM ON BOTH SIDES. �r Vii/ i NOTE: ALL STEEL STUDS MUST BE SCREWED TOP AND BOTTOM ON BOTH SIDES. •WALL PATITIO\ UL NO. U465 •WALL PATITIO\ UL NO. U465 <>1 HOU. WALL PATITIO\ UL NO. U465 DOOR SCHEDULE SEE RESPONSABILITY SCHEDULE ON Ti. FINISH LEGEND ® SEE RESPONSABILITY SCHEDULE ON T1. NO.NOTES ROOM NAME DOOR SIZE DOOR MATERIAL DOOR FINISH FRAME MATERIAL FRAME FINISH HARDWARE GROUP NO. MATERIAL MANUFACTURER SPECIFICATIONS P-1 PAINT BENJAMIN MOORE BEIGE — #967 FLAT EGGSHELL 0 FRONT ENTRY 6'-0" X 7'-0" ALUM/GLASS GLASS ALUM. ANOD. ALUM. © 4, 5, 6, 7 P-2 PAINT BENJAMIN MOORE BEIGE — #967 SEMI—GLOSS P-3 PAINT BENJAMIN MOORE BLUE #2067-60 FLAT EGGSHELL O STOCK ROOM 3'-0" X 8'-0" METAL P-2 METAL P-2 OA 1, 2, 5, 6, P-4 PAINT BENJAMIN MOORE BEIGE — #967 SATIN LOW LUSTRE F-1 STAINED CONCRETE BY GC F-2 MALL TILE MALL TILE PER SOUTHCENTER SPECIFICATIONS 0-1 COVE BASE JOHNSONITE #86 — HUNTER GREEN — SALES AND OFFICE ONLY CL -1 GYP. BD. CEILING NEW PAINTED GYP. BD. CL -2 OPEN CEILING PAINTED DOOR HARDWARE OA ENTRY PUSH/PULL HARDWAREE W/ LOCKSET, CLOSER INTERIOR FINISH MATERIALS SHALL BE CLASS A OR CLASS B PER NFPA 101, 24-3.3, 1997 EDITION. BO PRIVACY LEVER HARDWARE (BRUSHED CHROME) NEW LOCK. KICK PLATES ON BOTH SIDES. DOOR NOTES O PANIC BAR HARDWARE WITH ALARM AND CLOSER 1. NEW DOOR SUPPLIED, INSTALLED AND FINISHED BY L.L.G.C. . 2. ALL NEW DOOR OPENINGS ARE NONBEARING OR NON—SHEAR WALLS. 3. SERVICE DOOR BUZZER WITH BUZZER STATIONS ABOVE CEILING AT CASHWRAP AND OFFICE. 4. EXIT DOORS SHALL NOT BE SUBJECT TO THE USE OF A KEY OR REQUIRE SPECIAL KNOWLEDGE TO OPERATE PER 2006 IBC 5. INSTALL WALL DOOR STOPS AT HEIGHT OF DOOR KNOB AT ALL DOORS THAT SWING INTO OR OUT TOWARD A WALL. 6. INSTALL DOOR SILENCERS. 7. NOT USED 8. SALES TO CORRIDOR DOOR TO HAVE A DORMA DOOR CLOSER WITH MODEL #DC—DSTHO "HOLD OPEN ARM" 9. L.L.G.C. TO INSTALL A WIDE ANGEL PEEP HOLE. ANY DOOR NOT CONFORMING TO THIS PLAN OR CODE SHALL BE UPGRADED AS REQUIRED PER ALL CODES. SWING AND FORCE TO OPEN DOORS SHALL MEET THE REQUIREMENTS OF THE IBC 2006 SELF CLOSING DEVICES SHALL MEET THE REQUIREMENTS OF THE IBC 2006 PANIC HARDWARE SHALL BE PROVIDED FOR ALL EXIT DOORS PER THE REQUIREMENTS OF IBC 2006 GENERAL NOTES 1. T.G.C. TO COVER WINDOWS WITH PLAIN PAPER UNTIL THE END OF CONSTRUCTION. WINDOWS MUST THEN BE CLEANED AFTER REMOVAL AND ANY TAPE ADHESIVE REMOVED. PAPER TO BE REMOVED AND WINDOWS TO BE CLEANED PRIOR TO TURNOVER 2. T.G.C. TO VERIFY DOORS IN THE MEANS OF EGRESS SYSTEM TO BE OPERABLE FROM INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 3. INTERIOR WALL AND CEILING FINISH MATERIALS IN MERCANTILE OCCUPANCIES SHALL BE CLASS A OR CLASS B PER NFPA 101, 24-3.3, 1997 EDITION. 4. T.G.C. SHALL PROVIDE SUFFICIENT NUMBER OF 2A1OBC FIRE EXTINGUISHERS SO THAT A FIRE EXTINGUISHER CAN BE REACHED WITHIN 75 FEET OF NORMAL TRAVEL FROM ANY POINT IN THE BUILDING. PLEASE TAKE INTO CONSIDERATION THAT FIRE EXTINGUISHERS SHOULD BE LOCATED NEAR EXITS. MOUNTING HEIGHT SHALL BE 4 FEET A.F.F. MAXIMUM. LEASE LINE i ADJACEN T TENANT EXISTING ELECTRICAL PANEL AND PHONE BOARD STOCKRO•M GWB SOFFIT ABOVE NEW STOREFRONT G.C. BY 0. MALL COMMON LEASE LINE SALES AREA GWB SOFFIT ABOVE LEASE LINE ADJACENT TENANT 000 10 --I(U co • Ct.! LEASE LINE SOU THCEN TER SHOPPING CENTER 812 Sou th cen ter Mall SPACE 236 Seattle WA 98188 Math c40. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith@smithco.org http://www.smithco.org/ Consultant Consultant Registration Issues and Revisions Architect Registration 6294 STATE OF WASHINGTON No. Date Issues By Check 1 10.21.13 PERMIT KLS FLOOR PLAN SCALE: 1/4" = 1'-0" MALL COMMON REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER Project Name Fuego Project Number 02008018,00 Description FLOOR PLA N Computer File CW05-2008—A1,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. A-1 LEGEND KEY SCHEDULE 1 2 :NEW CASHWRAP/BACKWRAP BY OWNER :FIXTURES BY OWNER SURFACED MOUNTED 'WALL STANDARDS AND HARDWARE BY OWNER INSTALLED BY GC, GC TO PROVIDE BLKG. DENOTES EXISTING WALL •_7.= _ - - -: DENOTES EXISTING WALL TO BE REMOVED :DENOTES NEW 3-5/8"x20 GA. © 24" 0.C. DIETRICH METAL STUDS ICBO # 4784P LA R.R. NO. 25132 a: SYMBOL DENOTES DOOR, SEE DOOR SCHEDULE FOR ADD'L INFO. 1. CONTRACTOR TO VERIFY ALL DIMENSIONS 2. DO NOT SCALE DRAWINGS ! ! ! FIXTURE LEGEND 0 0 DISDLAYa CASHWRAD 9 l 2 -WAY WALL_ STA` W/SH-L V -S DARDS TABLE TI -RED TA LES C_BES REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION EXISTING ELECTRICAL PANEL AND PHONE BOARD (3) ADJACEN T TENANT r--�IClJ STOCKRO NEW STOREFRONT G.C. MALL COMMON SALES AREA SOU THCEN TER SHOPPING CENTER 812 Sou th cen ter Mall SPACE 236 Seattle WA 98188 smith co. 318 terry avenue n seethe, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith@smithco.org http://www.smithco.org/ Consultant Consultant Registration Issues and Revisions No. Date ADJACENT TENANT 000 1 10.21.13 Architect Registration 6294 KEI REGISTERED ARCHITECT STATE OF WASHINGTON Issues By Check PERMIT KLS 13'-4" FIXTURE PLAN SCALE: 1/4' = 1'-O" MALL COMMON NOTE: CIRCULATION AILES BETWEEN DISPLAYS TO BE NOT LESS THAN 36" IN CLEAR WIDTH RECEIVED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER 1)13- 032t Project Name Fuego Project Number 0200801800 Description FLOOR PLAN Computer File CW05-2008—A1,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. A-1.1 CONTRACTOR'S NOTE WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE DRAWINGS. CONTRACTOR'S MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF WORK, TO TENANT REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION, EXTRAS WILL NOT BE ALLOWED FOR JOB OR CODE COMPLIANCE CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION. ti SCHEDULED WALL FINISH SEE INTERIOR ELEVATIONS, TYPICAL SCHEDULED PARTITION, SEE PARTITION PLAN, TYPICAL 5" MDF BASE PAINT P-4 TYPICAL FINISHED FLOOR SEE SCHEDULE WOOD BASE (E) SLAB 3" = 1'-0" MAXIMUM SLOPE SHALL NOT EXCEED 1:20 1/2" METAL SLUDDER STRIP 4" V,I,F, "I ALUM MIL FINIS (E) MALL TILE SCHEDULED STOREFRONT AND ENTRY, SEE SHEET A-1. (E) CONCRETE SLAB TO REMAIN, TYPICAL c) STAINED CONCRETE (E) MASTIC SET ALUMINUM THRESHOLD, WITH SILICON SEAL AND BACKER ROD BOTH SIDES, TYPICAL ENTRY TRANSITION 3"=1'-0" ADJACEN T TENANT EXISTING ELECTRICAL PANEL AND PHONE BOARD STOCK ROC NEW STOREFRONT G.C. \ BY MALL COMMON SALES AREA 101 Ir 10-6 ADJACENT TENANT 000 13'-4" FINISH PLAN SCALE: 1/4' = 1'-0" 19'- MALL COMMON 00 1/ 'ICU CO NOTE: CIRCULATION AILES BETWEEN DISPLAYS TO BE NOT LESS THAN 36" IN CLEAR WIDTH REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION ffu4 SOU THCEN TER SHOPPING CENTER 812 Sou th cen ter Mall SPACE 236 Seattle WA 98188 smith, co. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith@smithco.org http://www.smithco.org/ Consultant Consultant Registration Issues and Revisions Architect Registration 6294 STATE OF WASHINGTON No. Date Issues By Check 1 10.21.13 PERMIT KLS U RECEIVED CITY OF TUKWILA NOV 13 2013 PERMIT CENTER b Project Name Fuego Project Number 0200801800 Description FLOOR FINISH PLAN Computer File CW05-2008—A2.DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. IIc. A-2 ..EPLECTED CE LI\ G PLA\ GE\RAL \OTES: 1. DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. LIGHTING IS SHOWN FOR REFERENCE ONLY AS ELECTRICAL IS DESIGN BUILD BY CONTRACTOR. CONTRACTOR SHALL COORDINATE WITH DESIGN BUILD LIGHTING PLANS AND WESTFIELD THROUGHOUT CONSTRUCTION. 3. EGRESS PATHWAY LIGHTING, INCLUDING EXIT SIGNS SHALL BE PROVIDED BY TENANT AS REQUIRED BY LOCAL JURISDICTION HAVING AUTHORITY. 4. CONTRACTOR SHALL SUPPORT AND BRACE ANY AND ALL CEILING COMPONENTS INCLUDING BUT NOT LIMITED TO CEILING GRID, LIGHT FIXTURES, ETC PER SEISMIC RESTRAINT REQUIREMENTS SET FORTH BY 2009 IBC AND ASSOCIATED CODES AND REQUIREMENTS PER LOCAL JURISDICTIONS HAVING AUTHORITY. 5. CONTRACTOR SHALL CAP AND TERMINATE ALL EXISTING UTILITIES AND SERVICES ABOVE CEILING LEVEL AT ITS POINT OF ORIGIN. DEMOLITION SHALL INCLUDE, BUT NOT BE LIMITED TO, ELECTRICAL, MECHANICAL, SPRINKLER, ETC. 6. CONTRACTOR SHALL PROVIDE REQUIRED SPRINKLER AND FIRE ALARM PROTECTION WITHIN VACANT TENANT SPACE AS REQUIRED BY LOCAL JURISDICTION. 7. LIGHTING AND MECHANICAL LAYOUTS ARE SHOWN FOR REFERENCE ONLY, EXACT QUANTITIES FOR DEMOLITION SHALL BE FIELD VERIFIED AND CONFIRMED PRIOR TO CONSTRUCTION. 8. TENANT CONTRACTOR SHALL PROVIDE EMERGENCY LIGHTING AND EGRESS PATHWAY LIGHTING AS REQUIRED BY LOCAL JURISDICTIONS HAVING AUTHORITY. 9. CONTRACTOR SHALL FURNISH AND INSTALL FIRE ALARM, HORN STROBES, SPRINKLER, AND EMERGENCY LIGHTING FOR VACANT SPACE AS REQUIRED BY LOCAL JURISDICTIONS. DEFLECTED CEILI\G PLA\ <EY \ OTES: 01 SUSPENDED GWB SOFFIT AND FRAMING PER WALL SECTION. PREP AND PRIME TO LEVEL 4 FINISH. 02 RECESSED DOWN LIGHT PER ELECTRICAL DESIGN BUILD CONTRACTOR. FIXTURE TYPE, QUANTITIES, AND LOCATION ARE SHOWN FOR REFERENCE ONLY AND SHALL BE COORDINATED WITH DESIGN BUILD CONTRACTOR TO MEET LOCAL CODES AND JURISDICTION. 03 GWB HEADER/BULKHEAD TO RECEIVE GRAPHICS BY TENANT. RE: SECTIONS CONTRACTOR SHALL PREP AND PRIME TO LEVEL 4 FINISH. 04 NO CEILING THIS AREA, OPEN TO STRUCTURE. TENANT CONTRACTOR SHALL FURNISH AND INSTALL LIGHTING, INCLUDING BUT NOT LIMITED T0, GENERAL LIGHTING, EMERGENCY LIGHTING, ETC. AS REQUIRED BY TENANT AND LOCAL JURISDICTION. CONTRACTOR SHALL PAINT ALL EXPOSED ITEMS "BLACK" UNLESS NOTED OTHERWISE. 05 MECHANICAL DUCT AND DISTRIBUTION. RE: MECHANICAL. CONTRACTOR SHALL COORDINATE FINAL DISTRIBUTION WITH TENANT. METAL STUD FRAMING AS REQUIRED FOR SUPPORT (E) METAL STUD FRAMING AND GWB AT MALL CEILING (E) MALL CONCOURSE GWB CEILING I( 1 HEAD DETAIL 3" = 1'-0" TYP 3\ HEAD DETAIL 3" = 1'-0" 1/2" THICK TEMPERED GLAZING BACKER ROD AND CAULK ALUMINUM STOREFRONT FRAMING 1/2" THICK TEMPERED GLAZING (E) MALL CONCOURSE GWSCEILING 5/8" GWB AND 3 5/8" METAL STUD FRAMING BACKER ROD AND CAULK ALUMINUM STOREFRONT FRAMING 1/2" .THICK TEMPERED GLAZING LEASE LINE ALUMINUM STOREFRONT FRAMING AT SILL BACKER ROD AND CAULK SILL DETAIL METAL STUD FRAMING AND GWB 3" = 1'-0" ti PAINTED GWB SOFFIT DOOR HEAD DETAIL METAL STUD FRAMING AND GWB DOUBLE ACTING DOOR STILE AND RECESSED CLOSER DOOR STILE AT HEAD 1/2" THICK TEMPERED GLAZING 3" = 1'-0" INFILL MALL CONCOURSE TILE TYPICAL 11111110IIIIIIIII UIIIIIWIIIIIII IIIIIIOIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIII (E) ADJACENT TENANT SPACE — NO WORK THIS AREA ADJACENT TENANT 000 EXISTING LIGHTING TO REMAIN STOCKROOM L07 L07 L07 L07 L07 a o o io 0 MTG, HT. 9'— NEW STOREFRONT G.C. \ OPEN CEILING MALL COMMON 0 (E) MALL CONCOLRSE SALES AREA ADJACENT TENANT 000 1 /1 REFLECTED C FILING PLAN SCALE: 1/4" = 1-0" The pati -of egress-shaH-show sufficient illuminallou of -1 footcandle-at— the walking surface leading to the exit discharge coorways MALL COMMON 00 E — EXISTING FIXTURE REFLECTED CEILING LEGEND R — RELOCATED FIXTURE N — NEW FIXTURE 0 V ® EXIT SIGN — CEILING MOUNTED # EXHAUST FAN / LIGHT COMBO LIGHT TRACK WITH HEADS O RECESSED DOWN LIGHT 9..P EMERGENCY LIGHT — CEILING MOUNTED 4' STRIP LIGHT MECHANICAL CONTRACTOR'S NOTE CONTRACTOR'S NOTE CEILING MOUNTED MECHANICAL EQUIPMENT TO REMAIN. G.C. TO RELOCATE SUPPLY AND RETURN DIFFUSERS AS NECESSARY PER NEW WALL LAYOUT. G.C. TO VERIFY THAT THE LOCATION OF THE EXISTING EQUIPMENT DOES NOT INTERFERE WITH NEW CONSTRUCTION. WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE DRAWINGS. CONTRACTOR'S MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. WITH THE PROPER EXECUTION OF WORK, TO TENANT REPRESENTATIVE. OF CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED FOR JOB OR CODE REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START COMPLIANCE CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION. Y2" THICK TEMPERED GLAZING DOOR STILE AT FLOOR FINISH FLOOR PER TENANT TRANSITION OF FLOOR FINISH AT CENTER LINE OF DOOR NOTE: CONTRACTOR SHALL PROVIDE REQUIRED CLEARANCES AT THRESHOLD FOR FLOOR FINISHES (INCLUDING TENANT FINISHES) THRESHOLD DETAIL 3" = 1'-0" METAL STUD FRAMING AND GWB Y2' THICK TEMPERED GLAZING — TYPICAL ALUMINUM STOREFRONT SILL BELOW GLAZING CLIP — TYPICAL OF (2) PER JAMB PERIMETER EDGE TRIM c>> 3/4" THICK MARLITE PANEL WITH P—LAM (PL -1) PER FINISH LEGEND JAMB DETAIL 3" = 1'-0" CE -3) Y2" GAP — MAXIMUM 1/2" THICK TEMPERED GLAZING TYPICAL GLAZING CLIPS RECEIVED AS REQUIRED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER GLAZING DETAIL 3" = 1'-0" ffag SOU THCEN TER SHOPPING CENTER 812 Sou th cen ter Mall SPACE 236 Seattle WA 98188 smith co. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith@smithco.org http://www.smithco.org/ Consultant REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION Consultant Registration Issues and Revisions Architect Registration 6294 KEI STATE OF WASHINGTON No. Date Issues By Check 1 10.21.13 PERVIT KLS Project Name Fuego Project Number 0200801800 Description REFLECTED CEILING PLAN Computer File CW05-2008—A3,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. IIc. A-3 LEASE LINE EXISTING NEUTRAL PIER WITH " BLACK ALUMINUM REVEAL LINE OF STOREFRONT BULKHEAD GWB-PAINT REVERSE CHANNEL LETTERS COORDINATE WITH TENANT SIGN MANUF, FRONT LIT BRUSHED ALUMINUM GLAZING CLIPS MIN. (2) AT EACH BUTT GLAZED JOINT SEE DETAIL 8/A-3 INTERIOR ELEVATION (uJ 0) (N)TENANT STOREFRONT BULKHEAD `J +— 15-6" AFF T.O. STOREFRONT +/— 13'-0" AFF B.O. BULKHEAD GLAZING CLIPS — TYPICAL (2) AT EACH BUTT GLAZED JOINT ALUMINUM STOREFRONT AND 1/2" THICK GLAZING, TYPICAL ALUMINUM STOREFRONT SILL 6" TILE BASE FINISH FLOOR 0'-0" W J - 4" PLYWOOD AT TOP MALL BULKHEAD METAL STUD DIAGONAL BRACING AT 4'-0" O.C. MIN. 5/8" GWB AND 6" METAL STUD FRAMING AT BULKHEAD SECTION SCALE: 1/2" = EXISTING MALL BULKHEAD PAINT TO MATCH EXISTING MALL CEILING REVERSE CHANNEL LETTERS COORDINATE WITH TENANT SIGN MANUF, PR❑VIDE POWER, CONDUIT AND J -BOX AS REQUIRED NEW GLASS STOREFRONT 3f TEMPERED WITH GLASS PATCHES NEW 6'-O' X 1-1/2" BRUSHED ALUMINUM PULLS MARLITE PANELS WITH 1" ALUMINUM REVEALS - ALUM. MIL FINISH NEW 6" TILE BASE Cf)Iw LU; LINE OF STOREFRONT BULKHEAD GWB-PAINT REVERSE CHANNEL LETTERS COORDINATE WITH TENANT SIGN MANUF, FRONT LIT LINE OF STOREFRONT BULKHEAD GWB-PAINT EXISTING MALL BULKHEAD PAINT TO MATCH EXISTING MALL CEILING REVERSE CHANNEL LETTERS COORDINATE WITH TENANT SIGN MANUF, PROVIDE POWER, CONDUIT AND J -BOX AS REQUIRED NEW GLASS STOREFRONT W TEMPERED WITH GLASS PATCHES NEW 6'-0" X 1-1/2° BRUSHED ALUMINUM PULLS MARLITE PANELS WITH 1" ALUMINUM REVEALS - ALUM. MIL FINISH NEW 6" TILE BASE i" PLYWOOD AT TOP 2 1111111111 III IIIiIIIIIIIIIIIIIII BRUSHED ALUMINUM GLAZING CLIPS MIN. (2) AT EACH BUTT _ GLAZED JOINT SEE DETAIL 8/A-3 INTERIOR ELEVATION SCALE 1/4" = 1'-0° MALL BULKHEAD (N) TENANT STOREFRONT BULKH +/— 15-6" AFF T.O. STOREFRONT +/— 13'-0" AFF B.O. BULKHEAD 10'-0" 1" ALUMINUM HORIZONTAL REVEAL — TYPICAL OF 4 MARLITE PANELS WITH 1" REVEALS FINISH FLOOR 0-0" METAL S -UD DIAGONAL BRACING AT 4'-0" O.C. MIN. 5/8" GWB AND 6" METAL STUD FRAMING AT BULKHEAD C2 SECTION SCALE: 1/2" = 1'-0" ... REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 6 City of Tukwila BUILDING DIVISION (N) TENANT STOREFRONT BULKHEAD +/— 15-6" AFF B.O. MULLION 10'-0" • 0.01111 wlC w J A-5 TYP, 1 I I I I I I I I I I I I I I I I I I I EXISTING NEUTRAL PIER WITH " BLACK ALUMINUM REVEAL GWB TO 12'-0" METAL STUD DIAGONAL BRACING AT 4'-0" O.C. MIN. 5/8" GWB AND 6" METAL STUD FRAMING AT BULKHEAD PL MARLITE PANELS WITH 1" REVEALS — BEYOND 6" TILE BASE FINISH FLOOR 0'-0" PAIR OF GLASS STOREFRONT DOORS 0 72" PULL RE: HARDWARE GROUP 1 3 aftinow SECTION SCALE: 1/2" =1'-0" LEASE LINE MALL BULKHEAD 0_ 1— RECEIVED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER SOUTHCENTER SHOPPING CENTER 812 Sou th cen ter Mall SPACE 236 Seattle WA 98188 smith cfi. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith@smithco.org http://www.smithco.org/ Consultant Consultant Registration Issues and Revisions Architect Registration 6294 STATE OF WASHINGTON No. Date Issues By Check 1 10.21.13 PER \MT KLS Project Name Fuego Project Number 0200801800 Description ELEVATI❑NS/SECTI❑NS Computer File CW05-2008—A4,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. llc. A-4 TENANT LEASE LINE 2 1" METAL STUD FRAMING AND GWB BACKER ROD AND CAULK — TYPICAL ALUMINUM REVEAL (E) STEEL COLUMN TO REMAIN (E) METAL STUD FRAMING AND GWB TO REMAIN MARLITE PANELS WITH1" REVEALS AND PLASTIC LAMINATE (PL -1) FINISH 3 5/8" METAL STUD FRAMING AND GWB BLACK EXTRUDED ALUM BREAK METAL CAP PERIMETER TOP EDGE TRIM %" THICK MARLITE PANEL WITH P—LAM (PL -1) PER FINISH LEGEND (E) ADJACENT TENANT STOREFRONT TO REMAIN (E) STONE BASE TO REMAIN NOTE: CONTRACTOR SHALL LINE UP FACE OF STOREFRONT WITH EXISTING ADJACENT STOREFRONT FOR A CONTINUOUS LINE OF STOREFRONT ALONG EAST ELEVATION NORTH NEUTRAL PIER DETAIL 1 1/2" = 1'-0" 3/4" PLYWD., TYPICAL 11111111111 1 PERIMETER TOP EDGE: NL770 EDGE TRIM COLOR: BLACK ALUMINUM TYP. TOP PERIMETER DETAIL 1" = 1" METAL STUD FRAMING RE: WALL TYPE 5/8" GWB, TYPICAL RE: WALLTYPE (E) ADJACENT TENANT STOREFRONT TO REMAIN TENANT LEASE LINE BACKER ROD AND CAULK TYPICAL 2' ALUMINUM REVEAL 0 (E) STONE BASE TO REMAIN 5/8" GWB, TYPICAL RE: WALLTYPE 3/4" THICK MARLITE PANEL WITH P—LAM (PL -1) PER FINISH LEGEND BLACK EXTRUDED ALUM BREAK METAL CAP MARLITE PANELS WITH1" REVEALS AND PLASTIC LAMINATE (PL -1) FINISH 3 5/8" METAL STUD FRAMING AND GWB SOUTH NEUTRAL PIER DETAIL 1 1/2" = MR 100 MAIN RAIL (E) STEEL COLUMN TO REMAIN 5/8" GWB — PAINTED TO REMAIN EXISTING 2 2" METAL STUD FRAMING — TYPICAL _\\\\\1\\\\D (3) 1" ALUMINUM REVEAL - %" THICK MARLITE PANEL WITH P—LAM (PL -1) PER FINISH LEGEND 1" HORIZONTAL REVEAL MR100 COLOR: BLACK ALUMINUM COLUMN DETAIL 1 1/2" = 1-0" METAL STUD FRAMING RE: WALL TYPE 5/8" GWB, TYPICAL RE: WALLTYPE TYP. HORIZ. REVEAL DETAIL 1 —1 • LILA OUTSIDE CORNER: NL760 0/C TRIM COLOR: BLACK ALUMINUM (9) TYP. CORNER DETAIL 1 -1 5/8" GWB, TYPICAL RE: WALLTYPE METAL STUD FRAMING RE: WALL TYPE 3/4" THICK MARLITE PANEL WITH P—LAM (PL -1) PER FINISH LEGEND OUTSIDE CORNER TRIM NL 760 0./C PERIMETER EDGE TRIM 5/8" GWB — TYPICAL FINISH LEGEND PAINT (FIELD COLOR © SOFFIT) GLIDDEN — 'NATURALLY CALM' #10YY 44/215 PAINT (FIELD COLOR CO CEILING): GLIDDEN — 'FOREST BLACK' #30YY 10/038 PLASTIC LAMINATE: FORMICA 9012—NT "EBONY" AT MARLITE PANELS PER PANEL MANUFACTURER'S REQUIREMENTS TILE BASE: 6" X 6" TILE BASE DAL—TILE: 'FESTIVA' SERIES — COAL #QF45\ GROUT JOINTS AND SEAL TOP AND BOTTOM EDGES l\\NM METAL STUD FRAMING 5/8" GWB, TYPICAL 1" ALUMINUM F—REVEAL LINE UP WITH HORIZONTAL REVEAL PERIMETER EDGE: NL770 EDGE TRIM COLOR: BLACK ALUMINUM FRY REGLET 'F' REVEAL (BASIS OF DESIGN): REVEAL WIDTH: 1" WIDE REVEAL DEPTH: %" (MATCH GWB SHEATHING MATERIAL: BLACK EXTRUDED ALUMINUM ALLOY — 6063 T5 MODEL NUMBER: FRY REGLET #FDM-625-100 (NON VENTED) TYP. DETAIL AT SOFFIT 1" = 1" 4" THICK MARLITE PANEL WITH P—LAM (PL -1) PER FINISH LEGEND Y2" THICK GLAZING WITH CLIPS 10 VERTICAL EDGE: NL770 EDGE TRIM COLOR: BLACK ALUMINUM TYP. JAMB DETAIL 1" = 1" 5/8" GWB, TYPICAL RE: WALLTYPE METAL STUD FRAMING RE: WALL TYPE BOTTOM OF GWB 10'-0" REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER SOU THCEN TER SHOPPING CENTER 812 Sou th cen ter Mall SPACE 236 Seattle WA 98188 smith co. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith@smithco.org http://www.smithco.org/ Consultant Consultant Registration Issues and Revisions Architect Registration 6294 KEI STATE OF WASHINGTON No. Date Issues By Check 1 10.21.13 PERvIIT KLS ►13- O3fB Project Name Fuego Project Number 0200801 8.00 Description DETAILS Computer File CW05-2008—A5. DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. IIc. A-5