Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D13-0349 - MASTERCRAFT - TENANT IMPROVEMENT
MASTERCRAFT 12628 INTERURBAN AVE S D13-0349 Parcel No: Address: 0 City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0004800003 12628 INTERURBAN AVE S Unit120 Project Name: MASTER CRAFT Permit Number: 013-0349 Issue Date: 12/13/2013 Permit Expires On: 6/11/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: GATEWAY OLYMPIA INC PO BOX 4900 #207 , SCOTTSDALE, WA, 85261 DAVID KEHLE 1913 BONAIR DR SW , SEATTLE, WA, 98116 Phone: (206) 433-8997 BOYCE CONSTRUCTION Phone: (206) 264-8085 270 S HANFORD ST #109 , SEATTLE, WA, 98134 BOYCECI066QQ Expiration Date: 1/21/2014 SELF FUNDED - CBRE DESCRIPTION OF WORK: NEW TENANT: CONSTRUCT NEW SINGLE STORY OFFICE OF NON-BEARING WALLS, NEW SUSPENDED ACOUSTIC CEILING, NEW RESTROOMS, NEW STOREFRONT AND NEW DEMISING WALLS. Project Valuation: $34,740.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Fees Collected: $1,247.61 Type of Construction: VB Occupancy per IBC: S-1 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: • r Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: I hearby certify that I have read an provisions of law and ordinances go A i 111.1 li+ � l exam rnin Date: ed this permit and know the same to be true and correct. All this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: .a4 Jr Date: I-7/ .77/3. This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and Tight fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. • 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 14: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 17: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 18: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 19: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 24: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) • 25: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 26: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 27: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 28: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 29: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 32: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH & GYPSUM 0603 ROOF/CEILING INSUL 0406 SUSPENDED CEILING 0601 WALL INSULATION CITY OF TAILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Q3 Project No. Date Application Accepted: J-4 -•..( 3 Date Application Expires: SN i S-- ( (For office use only) j1 CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Wid li o___it I _. o:). Tenant Name: f D'tEf2ii6r'r 'lig Co Assessor's Tax No.: oco4baDc0, Suite Number: VO Floor: 1 PROPERTY OWNER Company Name: �y,� 16�V Name:7 L / Le Address: 10 LIP--/ZN0&\t( , "� p'/ { WStat�Jqw �/�„rit m O / City: -•�"'1 Zip: C,e, CONTACT PERSON — person receiving all project communication Company Name: �y,� 16�V Name: (.ldl, / Le Address: Address: mitt, le, City: State: City:Gmtiz"1 State:\iy6, Zip lj (0 Phone: ft. 4mq Fax: ftrolApp. City: Email: AKehi „ e tbehketycli. c.01µ GENERAL CONTRACTOR INFORMATION Company Name: �y,� 16�V Architect Name: pKII2 Kole Address:11 Ili, vainRZ j Address: Phone:4.433 4,I,1"1.� Fax: ,,, ,I, _,e30q 1 Email: f. City: State: Address: Zip: Phone: Fax: City: State: Contr Reg No.: Exp Date: Fax: Tukwila Business License No.: Email: H Wpplication1Worms•Applicuions On Line \2012 Applications+Permit Appitcation Revised • 2-7.12 docs Revised Febniary2ttl2 hh New Tenant: Yes ❑.. No ARCHITECT OF RECORD ,.,� Company Name: iv, e%rIw .brzji1 Architect Name: pKII2 Kole Address:11 Ili, vainRZ j City: .1+r . StateUWA Zip:0 f 4, Phone:4.433 4,I,1"1.� Fax: ,,, ,I, _,e30q 1 Email: f. a.� Lrr]P�t�EaNt.tit. (H ENGINEER OF RECORD Company Name: 14,'t �'C Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: Pv#206 a's' City: State: Zip: Page 1 of 4 DU,11.1.111111.3 rI.giv1it 1NFORMATI—206-431-3670 • Valuation of Project (contractor's bid price): $ 4040 1 Existing Building Valuation: $ a % flu-lt+N Des ribe the scope of work (please provide detailed information): OCU) Stnueir 4 'ti les 4 a' DFS e - I l Vl�u� uev Ou ffvuveo CEI t,I r i4 iJev , Lie0 9-' /am WJ l,L. Will there be new rack storage? ❑ ....Yes rANo If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below i" Floor rd Floor 3rd Floor Existing Interior Remodel 119 00 Addition to Existing Structure 4 New 4 Type of Construction per IBC Type of Occupancy per IBC Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION; Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: CaLot Area (sq ft): Nb N4EV Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal/�ci,,owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 00 6404 Compact: Will there be a change in use? 0 Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data ta Sheets. :EPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Handicap: lApplicationalForms-Applications On Line120I2 Applicationr'Permit Application Revised • 2.7-12.docr vited February2012 Page 2 of 4 I PERMIT APPLICATION NOTE. • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY TI•IAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW R OR ORIZED AGENT: Signature: Nog Date: Ill 13 Print Name: av11% `�t�' Day Telephone: 4O (o -43S -0(16i Mailing Address: 1/3 %(0 r 'I4 le- rNkirtt to, gait(' -"' =- -.4',; ^-1++ca1 On Line\2012 Applicadons\Permit Application Revised - 2-7-12 docx City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $757.90 D13-0349 Address: 12628 INTERURBAN AVE S Unit120 Apn: 0004800003 $757.90 DEVELOPMENT PERMIT FEE WASHINGTON STATE SURCHARGE TOTAL FEES PAID BY RECEIPT: R380 R000.322.100.00.00 B640.237.114 $757.90 $753.40 $4.50 $757.90 Date Paid: Friday, December 13, 2013 Paid By: BOYCE CONSTRUCTION INC Pay Method: CHECK 21983 Printed: Friday, December 13, 2013 12:52 PM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID $489.71 D13-0349 Address: 12628 INTERURBAN AVE S Apn: 0004800003 $489.71 DEVELOPMENT PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R96 R000.345.830.00.00 $489.71 $489.71 $489.71 Date Paid: Wednesday, November 13, 2013 Paid By: DAVID KEHLE Pay Method: CREDIT CARD 055463 Printed: Wednesday, November 13, 2013 1:50 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: OV-\(;10-012(11.---TWit Type Inspection: . 11•Ac .- . Address:Date 1 -,>J; bile N Called: Special Instructions:. Date Wanted:.rn 30 —44 P.m. Requester: Phone No: Approved per applicable codes. DCorrections required prior to approval: COMMENTS: irSspect n Date: 1-3 0-11 REINS ECTION FEE REQUIRED. Prio to next inspection. fee must be paid a 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.. L. . INSPECTION RECORD Retain a copy with permit -(0-1 PERMIT NO. CITY OF.TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451. Project: y 1AS-ke.,r'( i,�t= { Type of IInspection:. (",,,_AZ )(— /0ao C'P,1AS Address: f 2(02P. .U44ft. ✓!oo ;.J . Date Called: --4--N-1 s'.- — d Special Instructions: i2C) Date Wanted: G (,..__ a-! -- Requester: , Q .,, Phone N Approved per applicable codes. D Corrections required prior to approval. COMMENTS: f402 a✓e ( Date: r1I1 El/ SPECTION FEE REQU1 ED. Prior to next inspection. fee must be payl at. 6300 Southcenter B yd.. Suite 100. Call to schedule reinspection. 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 DI 3-o3y`t Projer.I e._ 1--.t.. r C A�- TYp��U• pr n At1 s(0� V 3 14\oitd V , Date Iled: p,f N PFbC9 E 1 L; Al 6 Special Instructions: Date j aant d , f `i I `-i Requester: Phone No: Approved per applicable codes. E1 Corrections required prior to approval. COMMENTS: ( ID SutStsFkIr c C&ILla./6 — A -PP/ 60. i )E i%F 1niC. , +i»1, iSSuFk/(' sea - / `` Date: I PECTION FEE REQUIRED.( Prior to next inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD D13•0341 INSPECTION NO. _C\' , PERMIT NO. CITY OFTUKWILA BUILDING DIVISRAlt 63 -0•S ujthcenipr�Blyd�,190Q Tukwila. WA 98188 (206) 431-3670 PermitAlnspectio Request Line (2d6)1431(2451 . -> iRetain.,a copy withpermit Project: AA Type of Inspection: '_ Address: 12 QL? .T.nTerurit-N Date Called: ,--, Special Instructions: Ir 240l U A �/ Date Wanted: (l. — (If a.m Requester:t Phone No+ ► I -1 A0proved per applicable codes. Corrections required prior•to•approvaP.: COMMENTS!' , . k,,, " ' 4 . '_ r { t -, i 'y1 I .,r lnsp{ctor: Date: 1 cp n REINSPECTION FEE R QUIRE?. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. Dia CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: y llAs�r�f - -. Type of Inspection: • 1-2AmMk►ee, Address: 2 2.8 S000lzt 6A 1 Date Ca {�d: ,, J Special Instructions: Date Wanted: Req ester: ,t i' SI1� x.127 -C '137 Phone No 2Ctr)-2(04= a55 fpproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspec r' Date: n E� SPECTION FE REGI to next inspection. fee must be id at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1.Z REQUIRED. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1713--D3(19 )3-F- so & (3-S- 3o$ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: ,914/t(rA A!O Type of Inspect' n: F4 ///41 Address: Suite #: %2(0 223 —, S -/Z- Contact Person: Monitor: Special Instructions: //4fgfrvc Phone No.: Permits: )(Approved per applicable codes. Corrections required prior to approval. COMMENTS: ,-� ,,1.- A ----- 4ss /1/0./eii ok ZDy Needs Shift Inspection: A!O Sprinklers: /..e..3Fire Alarm: /..e 1 i ZS iv Hood & Duct: Monitor: p(j/ //4fgfrvc Pre -Fire: Permits: (,//v/� Occupancy Type: ,g Inspe • r• G S 5 Date: i ZS iv Hrs.: / 0 / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaJI to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 13 -Q tt5) 13-f_- 308 /3 -s - 3's PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Sprinklers: Fire Alarm: Type of Inspection: Address:..)4 Suite #: / GZ 8 �4S 12;0 Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 3 ok7 -, - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits:Occupancy Type: 1 Inspector: / , ySj Date: x,05/ y Hrs.: /, i) $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing; Address Attn: Address: Company Name: Stater Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 I INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit bl3-o33e( 6 I 3- s — 305 - PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: M o --5\-e r CV- GA` Sprinklers: T e of I spection: /�- S( Address: 13 Suite #: 6 (3 46,. , Contact Person: Special Inst t&ions: Phone No.: Approved per applicable ‘\_ co Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 1, A 6 (1 _s (bvt) 7—o pi/ A , P_ 14 al- Nc-Q, Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:,---... Date: /A___ 7 pV Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 \limCbv . 9' ��' = OcuN wiz=_zo 16254 27 x21 cel Itffl REVIEW -ED -FOR- -CODE -COMPLIANCE APPROVED NOV 27 1013 6etut4A - �I ofWkv�la___� BUILDING DIVISION kw,c, Nei) knittki RECEIVED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER Element: SKETCH OF ELEMENT Note: Make copies of this forrn for every building element. Framing Ratio (if applicable) = ,(5 s Average U Value = 'Value for Element (Avg.) = (U Solid (Framing Raffc) U (Cavity Rado)112 Area of Element* = " Area of Element is net area after openings suc as bccrs: ‘,./nbcws sylights have t een subtracted. •.I .14 Materials Thickness (Inches) R / Inch Thickness R Value Solid R Value Cavity 1) &cosi (76 4Q- A:e 0, 2) it.dlI -U r (t.lacrE & Z' 1 ,,`A -( • 0 . - • 3) Vi(il 0 iklcAlltTht•I :•50 4) Hriiv ---- .-- _. 5) EMT- l.1i191ibt.i 2,1 6) \biza. 15602.01e2.____ — — 8) t510E IC1(2- 19t.4-1 0.1 9) 10) 11) Total R Values U Value = 1iR D•(..) 5-.' ,(5 s Average U Value = 'Value for Element (Avg.) = (U Solid (Framing Raffc) U (Cavity Rado)112 Area of Element* = " Area of Element is net area after openings suc as bccrs: ‘,./nbcws sylights have t een subtracted. •.I .14 ENVELOPE U -VALUE WORKSHEET Element: Rtztpurrez.. ALL. SKETCH OF ELEMENT Note: Make copies of this form for every building element. Framing Ratio (if applicable) gm Co ii d►'fi..9t17. a 11460401.1 %(1a`tp.. Fb Materiel ft +-,G, Thickness (Inches) R -Value per Inch R -Value Solid .s(p R -Value Cavity _421' Sum of R -Values U o 1/R Framing Ratlo Solid U-Ve lue x Framing Ratio U w 1/R 1 • Framing Ratio Cavity U•Value x (1 - Framing Ratio) Sum of Adjusted U -Values le + bl e) b) L'. (-4,/ Area of Element - Net aree after openings such es doors, windows, end skylights have been subtracted ti • Element: C6, 1/.2- SKETCH 2 SKETCH OF ELEMENT Note: Make copies of this form for every building element. Framing Ratio ( applicable) Material Thickness Inches R/ln Thickness R Veue Solid R value Cavity -41 -+! (, 11 1/.... ?. r I.: i IHu le NtA, .01 ummation R Va'ues U = 1/R U Vaue for Element (Avg.) Area of Element* W Area of Element is net was atter openings such as doors, K:.nda,,,5 and syighs ha:e been subtracted. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Interior Lighting Summary 12 Washington State Energy Code Compioe Faros Group #?t.. ane 3 *my R2 at R3 LGT-SUM Revised June 2013 Project Info P0iect pale --...�..- 1 Z ,7,f, fI d'(Ltl,i ehil AVE Gb: (lit, 120.• For. . Department Use Its(' Y1 Ilettic hiltiri APPricant Addiressz D7i4bie.Ptii . Applicant Phone://tP 3 -M'1 - Project Description ■ New Budding 0 Addition 14 Alteration ■ Plans Included Lighting Compliance Path • 0 Lighting Power Density Calculations 0 Total Building Performance (f Total Building Performance then only LGT-CHK is required.) Interior Lighting Compliance Option O Building Area Method QQ Space -by -space Method , ., Interior Lighting System. Description Briefly describe lighting system type and features. REVIEWED REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 Additions and Change of Space Use (C101.4.3 & C101.4.4) rowila e; o` A Addition area or Change of Space Use area complies with all applicable provisions as stand aI IX NG DIVISION �i+ • Addition area or Change of Space Use area is combined with existing building lighting system compliance with all applicable provisions Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use scope. Provide appicatale %eating controls per C405.2 and commissioning of lighting controls per 0405.13. Alterations, Renovations and Repairs (C101.4.3.1) TA 60% or more of luminaires in space replaced Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document marks= allowed and proposed (including existing) lighting wattage of project scope • Less than 60% of luminaires in space replaced Provide Space -by -space Method (LTG -INT -SPACE) Compliance Fonn. Document existing total wattage in space and proposed (including existing) lighting wattage of project scope • Lamp and/or ballast replacement within existing luminaires only - existing total interior building wattage not increased • New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (0405.2.2.2), daylight zone controls (0405.2.2.3), specific application controls (0405.2.3), and commissioning of lighting controls per 0405.13 ■ New or moved lighting panel Provide all applicable lighting controls as noted for New wring, automatic time switch controls (0405.2.2.1), and commissioning of lighting controls per 0405.13. a Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wining and commissioning of lighting controls per C405.13. • No changes are being made to the interior lighting and space use not changed. R E C E 1 V F I CITY OF TUKWILA NOV 132013 PERMIT CENTER 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Interior Lighting Summary - Space -by -Space LTG -INT -SPACE 2012 Washington State Energy Code Carnpianoe Form iv 3 Story R2 and R3 Revised June 2013 Project Info Prof Address 1%i " Date I1 ' t� I7/„Z k)��it 'Pr's We f ,e W" Watts Proposed For Building apartment Use X4 iit e d�; Applicant Name 10 Lel kOri I'j . Maximum Allowed Lighting Wattage Location (plan #, room #, or ALL) Space Type* Allowed Watts per ft2 Bross intenor Area in ft2 watts mowed (watts/ft2 x area) It f ILL. f IGt; Mt IIT lob 619 Atrium** Enter Height: Retail Display Allowance from LGT-INT-DISPLAY " Select Table C405.5.2(2) category from drop down menu. ** For atriums, indicate height Allowed wattage for first 40 feet is 0.03 W/ft. ht., above 40 feet is 0.02 W/R. ht. Provosed Li tin Wattage Total Area Allowed Watts Ii9b IO94 Location (plan #, _ room #, or ALL) T Fixture Description (Include exempt equipment per Note 3) Number of Fixtures Watts/ Fixture Watts Proposed rte t X4 iit e d�; 0 t-4- Zx$ 21"�-t� rE.-- 41,!f �c' t riA ;� 619 Retail Display Lighting from LGT-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1 Q Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 7 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Lliigihtin g,. Motor, and Transformer Petrrrut Plains Checklifst LTG-CHSK 2012 Wasengton State Energy Code Ccmp5ance Forms tar C.onavnercal,sting- Group RI, arsd > 3 sy R2 and R3 Revised June 2013 Project Address 12 /0 Z b I ktn �I1,r � /� R- /�J� 1 17i, Date`, .+.3 .\ The following information is necessary to check a permit application for rxxnptiance with the lighting, motor, and transformer requirements in the 2012 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section C405 2) v 0405 2 1 Manual lighting controls Lighting control schedule with type, locations served, 50% lighting reduction method A. I 'Z J C405.2.2.1 Automatic time switch controls Lighting systems automatic shut-off capability - indicate method and location served on plans. Note locations where automatic shutoff is provided by other method (occupancy sensor, daylight controls, etc) IOverride switching Schedule with locations served - no single override switch exceeds an area of 5,000 SF C405.2.2.2 Occupancy sensors Schedule of locations served C405.2.2.3 Daylight zones `1.-7, 1 Vertical fenestration Primary and secondary daylight zone areas indicated on plans 1 , Z ithek Skylights Skylight daylight zone areas indicated on plans til ,405.2.2.3.E Daylight zone controls Lighting control schedule with dimming method and locations served - no single daylight control zone exceeds 2,500 SF "-Z. �. II �Jf 11��''"'777777 0405.2.3 Specific application controls Specific application lighting controls are independent of general area lighting and controls for other lighting applications Means of egress lighting Lighting control schedule with method and locations served. Note luminaires that function as both normal and egress. Display lighting Lighting control schedule with type and locations served Accent lighting Lighting control schedule with type and locations served Hotel/motel guest rooms Lighting control schedule with type and locations served Supplemental task lighting Lighting control schedule with type and locations served Non-exempt lighting equipment Lighting control schedule with type, applications served and locations Non-exempt lighting equipment Lighting control schedule with type, applications served and locations 0405.2.4 Exterior lighting controls Lighting control schedule with type, features and location served INTERIOR LIGHTING POWER (Section C405.5) t-( n 0405.5.1 Total connected lighting power Schedule with fixture types, lamps, ballasts, watts per fixture — b• Z t4i Space exceptions Space exceptions taken noted on plans or compliance form Lighting equipment exceptions Equipment exceptions taken noted on plans or compliance form 0405.5.2 Lighting power calculations Building Area Method Compliance form completed — proposed wattage per building area does not exceed maximum allowed wattage Space -By -Space Method Compliance form completed — total proposed wattage does not exceed maximum allowed wattage C405.4 Exit signs All internally illuminated exits sign are < 5 watts per side EXTERIOR LIGHTING POWER (Section C405.6) C405.6.2 Total connected lighting power Schedule with fixture types, lamps, ballasts, watts per fixture Exterior application exceptions Exterior application exceptions taken noted on plans or compliance form Lighting power calculations Compliance fort completed — proposed wattage for exterior lighting plus base site allowed does not exceed max. allowed 0405.6.1 Exterior building grounds lighting Schedule with fixture types, lamps, ballasts, watts per fixture; lumens per watt for fixtures > 100 watts ELECTRICAL POWER SYSTEMS (Sections 0405.7 ,0405.9, C405.12, 0409.2.1) 2_• Sate Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 R3 Envelope Summary ENV -SUM -• 2 itiaaanirgror 32m Ermr.ni•_.toe :ar.-tsisr-ce 7-x•rs . _-.- > > . R & R3 Razsec .Ane 2013 Project /ado C hir u, Date11.I .` 1,z,t. ( az1 r e360 .. 0:7 . j-t•E (•o For BuddingDepartment Use .va AA!& 46+¢ P2 9y MIttleIV69,E114s Project Des ription L.'. New Building ■ Addition 14 Alteration ❑ Change of Occupant Corlarlen-n,• Compliance Path ❑ Prescriptive -tyf Component Performance :.2. Total Building Per`o^rarvce Occupancy Group 4 Commercial 0 Group R (R-1 & > 3 story R-2 arta R-3) Climate Zone Climate Zone iiiii9 0 Climate Zone (ib( See WSEC 301 1 !cc • -.r.:n-: Vertical Fenestration and Skylight Area Calculation If complying via the Pisscrilive path, values for vertical fenestration, skylights, gross walls end roof. If complying via the Component Performance path, these values are auto- filled by the ENV -UA form and cannot be edited here. Total Vertical Gross Exterior Fenestration Above Grade 'lei -ice! (rough opening) divided by Wall Area times 100 equa5 Ferlesraz.on I X ,) 00 = la Gross Exterior Total Skylight divided by Roof Area times 100 equals % Skylight 4 X 100 = kik Maximum Prescriptive p Fenestration Area Vertical 14 L -ad ki..M I u Ut'1 4 l bf9U ik OWOiti Fenestration U ;. 8i-3 0 Skylights Ol jti _ _. Rt'n FOP 50% Floor Area in DLZ 0 More than 50% of the floor area in daylight zone per E COMPLIANCE 11 Semi -Heated Path (j I`�' 111Project has semi -heated areas as defined per C402.1.4 • Applying wall exception to semi -heated areas 1. To be deemed semi -heated the area is heated but not output capacity between 3.4 - 8 Btuhfft2. Refer to C402.1. 2. Semi -heated spaces shall be documented separately fro separate compliance forms for each conditioned area type. 3.Semi-heated spaces may comply under the Prescriptive path. APPROVED NOV 2 7 2013 led, and has a max. heating system fOr requirements. other ac .. �p�ces11- provide ,• t:nlmVl v,'ce 4.Envelope elements separating seml-heated from other con 'boned spaces shall zmpy with thermal envelope requirements for en exterior wall. Refrigerated Spaces ' • Walk-in cooler ■ Walk-in freezer • Refrigerated Warehouse Cooler 0 Change of Occupancy7Corndrioning Refrigerated spaces shall comply under the Prescriptive Path only. Compliance dx:~r e - ti these areas may be combined with non -refrigerated areas in the ENV-PRESCi I? i 7VE `err; ----8.181". Mixed Occupancy and/or Space Conditioning Project includes more than one occupancy type and/or level of space conditioning. Mi±cdae compliance forms may be required. Select all that apply to scope of project: A Commercial ■ Group R1 or>3 story R2/R3 0 Refrigerated Space 134 Fully Conditioned ■ Semi -Heated ❑ Low Energy 0 Group R2/R3 < 3 story *Low energy areas are exempt from all thermal envelope provisions and cccompliance forms for these areas are not required. Refer to C101.5.2 for exemption. 1)l3 031 CITY OF TUKWILA NOV 1 3 2013 2012 Washington State Energy Code Compliance Forms for Commercial. Group R1, and > 3 s:cay P.2 R3 Envelope Summary (back) ENV -SUM 2012 Was.`tincgtar. State Enerr., C- Cc rtatanoa Forrrts fw Ccxrmercza1 R yr_ > 3 s..r. R2 & R: -:.,sec JI! Y - Minimum Requirements for Prescriptive Option Use tao+e to ,.e.efr- re LL :rpm- 3ua:. ta2s:re%. re Oc r.. .AEI cornoc..rents must reoutrerrMera for rte ter-: rr.ee amer. Climate Zone Climate Zone 4c/5b Climate Zone 6b Occupancy Group All Other Group R All Other Group R Opaque Elements Insulation Min. R-Value''r Roofs Insuiazien Entirely above Deck R-30 c.i. R-38 c.i. R-38 c.i. . R-30 c.i. Metal Buildine (with R-3.5 thermal blocks l't. R-25 +R-11 Ls R-25 +R-11 Ls R-25 +R-11 Ls R-25 + R-1 I Ls Attic and Other R-49 R-49 R-49 - R-49 14 ails, Above -grade Mass R-9 Sc.i ` R-113 c.i c R41.4 el' R-15.2 c.i.` Metal Building M R-13 + R-13 c.i. R-13 + R-13 c.i. R-13 + R-13 c.i. R-19 + R-16 c.i. Steel Framed R-13 + R-10c.i. R-19 + R-8.5 c.i. R-13 + R-12.5 c.i. R-19 + R-14 c.i. - Wood Framed and Other R-21 int R-21 int R-13 + R-7.5 c.i., or R-21 + R-3.8 c.i. R-21 + R-5 c.i. Below Grade Wall Same as above grade Same as above grade Floors Mass R-30 c.i. _ R-30 c.i. R-30 c.i. R-30 c.i. Steel Joist (per footnote c) R-38 + R-10 c.i. R-38 + R-10 c.i. R-38 + R-10 c.i. R-38.0 + R-10 c.i. Wood Framed and Other R-30 R-30 . R-38 R-38.0 + R-10 c.i. Slab -On -Grade Floors _ Unheated R-10 for 24 in. (with thermal break) R-10 for 24 in. (with thermal break). R-10 for 48 in. (with thermal break) R-15 for 48 in. (with thermal break) Heated R-10 perimeter & under entire slab R-10 perimeter & under entire slab R-10 perimeter & under entire slab R-10 perimeter & under entire slab Opaque Doors Maximum U -Factor Swinging U-0.37 U-0.37 U-0.37 U-0.37 Roll -up or sliding R-4.75 R-4.75 R-4.75 .R-4.75 Fenestration 0-30% of Wal! Assembly Maximum U -factor (NFRC Rated) - Vertical Fenestration Nonmetal framing U-0.30 U-0.30 U-0.30 U-0.30 1 Metal framing (fixed) U-0.38 U-0.38 U-0.36 U-0.36 Metal framing (operable) U-0.40 U-0.40 U-0.40 U-0.40 Entrance doors U-0.60 U-0.60 U-0.60 _ U-0.60 SAyllghts Skylights U-0.50 U-0.50 U-0.50 U-0.50 Fenestration 0-30% of Wall Assembly Maximum SHGC Factor Vertical Fenestration 0.2 S PFa0.5: PF<0.2: all orientations - SHGC-0.40 PF < 0:5: north - SHGC-0.44, all other SHGC-0.48 north - SHGC-0.48, all other - SHGC-0.64 Skylights SHGC-0.35 ISHGC-0.35 SHGC-0.35 ISHGC-0.35 For SI: 1 inch .= 25.4 mm. ci .= Continuous insulation (see footnote f). NR .= No requirement. LS .= Liner system -A continuous membrane installed below the purlins and uninterrupted by framing members. Uncompressed,unfaced insulation rests on top of the membrane between the purlins. a Assembly descriptions can be found in Chapter 2 and Appendix A. b Where using R -value compliance method, a thermal spacer block shall be provided, otherwise use the U -factor compliance method in Table C402.1.2. c R-5.7ci is allowed to be substituted with concrete block walls complying with ASTM C90, ungrouted or panially grouted at 32 inches or less on center vertically and 48 inches or less on center horizontally, with ungrouted cores filled with materials having a maximum thermal conductivity of 0.44 Btu-in/h-ft2 EF. d Where heated slabs are below grade, below -grade walls shall comply with the exterior insulation requirements for heated slabs. e Steel floor joist systems shall be insulated to R-38 .+ R -I Oci. f For roof, wall or floor assemblies where the proposed assembly has penetrations > 0.04% of the area, the assembly is not 2012 Washington State Energy Code Compliance Forms for Commercai. Group R1. and > 3 story R2 R_ Component Performance Path ENV -UA .2012 E-et ':.BOE n.Y!'r=.�-.ys =.r a Jr." r.."Yrr-ei.jet a.i •a c ' 5k'j R2 & R3 xc :tre 2 -? Pried Address 126%2,6 liiTc`ti.U.O64.1. kve 4b .. iitt 1.13 -.l3 Occupa.ncs Group 6=r,,.-:ef:2 - Crsp, K (R-1 & > 3 story S -2/R-3) Clear `o Bur-44PC De .a" -ent Use Climate Zone 4 zc ''L. Change in occupancy or space conditioning 4, Note - r"2C'c UA nay exceed Target UA by 10% per C101.4 4 and C101.4 5 Fenestration Area as % gross exterior AG wait area ( l % Max. Target: Skylight Area as gross exterior roof area a Max. Target: 500 o Floor Area in DLZ 0 zsc}': of tn.:::ocr2'c-ir,:avigni:o nc xr C302.3.1.1 Notes: 1: rf vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target Area Adjustment of all applicable envelope elements will be calculated by the compliance form. Refer to sheet on the backside of the ENV-SHGC form for this calculation. 2: U -factors shall come from Appendix A, chapter C303, or calculated per approved method as specified in C402.1.2. 3: Refer to ENV -CHK worksheet for example of how to complete the rows on this form. Building Component Provide source of U -factor, page/plan # of assembly detail & ID Proposed UA U -factor x Area (A) = UA (U x A) Target UA U -factor x Area (A) = UA (U x A) w °o o: Y 2 Q R= ID: R= ID: R= ID: Above Deck Insulation set occ. v m 2 R= ID: R= ID: R=ID: , ; I : i Metal Building: ' set occ. L 0 R=4t ID: P.»1T' 04 1XIt.IVcl R= ID: R= ID: 0,019 Ilya ti,ce I 17.02 , 1-1E, 2�,t(' Single raft, attic, other set occ. m € . g R=14.4 Zi ID: cj0„"7iktiDot'h-11.351.0 R=1.5.421 ID: RIZ R= ID: 6.0Gc7 0,0 9 I ct31 ejI.91- -Z 1.1, 44)Steel/metal 1 0.004- 14270 8Z.30 frame set occ. 1 Opaque Wails - Abol mi m 2 R= ID: R= ID: R= ID: Metal Building set occ. O 1 R= ID: R= ID: R= ID: Wood Frame, other set occ. • 2 2 R= ID: R= ID: R= ID: j ; ', Mass Wall set occ. 33 W To °'ct 13 R= ID: R= Il ID: I Assumed to be Mass Wall set occ. R= J.1 ID: R= ID: sJoold 1 ,,, 'Ai R= ID: R= illi ID: R= ID: i I Mass Floor set occ. -$ E P. u R= ID: R= ID: R= ID: i Joist/Framing set occ. F -factor , x Perimeter := UA(U x m F -factor x Perimeter = UA (U x A) ISlab -on -grade 2 0 R= ID: R= ID: R= ID. Slab -On -Grade set occ. , 2 R= ID: R= ID: R= ID: • I Heated Slab -On -Grade set occ. Tootno e rw>4terem n sppe �dKtt�P1�rit�rtr,e alue ix v u s. a s mus t r s e Page 1 Subtotal �f Area CIO/ ti (�K/1 1 2012 Was.rington Sz_.e _-,erg• Code Compliance Forrns for Commercial, Group R1, and > 3 story R2 R3 Envelope UA, continued. ENV -UA Pro, •L`less 17(p b 11 t12UP..13'.kei , jare IZa Date H. )3 • i 3 Fenestration Area ,.5:s e. ire crP_ia I i Yr Max. Target: For Building Department Use Skylight Area x ;-mss a ;oaf area Max.W% Target: Notes: per C402.3.1, then Target calculated by the compliance form. calculation. (combined frame and glazing complete the rows on this form. 1: rf sera/ o ..k•AgM ares exceeds maximum allowed :lam - Area --ner* ,; alf envebpe elements will be R r• weer. r r+e oarlside of he ENV-SHGC tom, for this 2: = ror+oe NFRC a' Acoenoix A tJ-tactcr for fenestration assemby periarrrrarre) 3: Refer to ENV -0-1K worksheet for example of how to Building Component Provide source of U -factor, page/plan # of assembly detail & ID Proposed UA U -factor x Area A = UA (U x A Target UA U -factor x Area,.,.:-.)) = UA (t 1 ,r A) o, a 1 $ co 0 U=0((iv ID:G�G J Q U= ID: U= ID: bid (e.'" .90 .90 (9.(eo 31.4 Opaque Swing Doors set occ. mg, — $ ce U= ID: U= ID: U= ID: I Opaque rotlup & siding set occ. Vertical Fenestration _ 1 Non -Metal U= ID: U= ID: U= ID: U= ID: i Non -Metal Frame set occ. Metal, fixed U=6r3b ID:le,etr17041- U= ID: U= ID: U= ID: e2/6, ' 1,-11 fe4-,'48 I I it a,. 0i (e4,Te Metal Frame, Fixed set occ. Metal, op. U= ID: U= ID: U= ID: U= ID: i i I Metal Frame, Operable set occ. i MtI entrance' U= ID: U= ID: U= ID: U= ID: I Metal Entance Door set occ. ' Skylights v, — U= ID: U= Li ID: U= r ID: U= ID: ; I All types set occ. Page 2 Subtotal Page 1 Subtotal To comply: 1) Proposed Total UA shall not exceed Target Total UA. 2) Proposed Total Area shall equal Target Total Area. Total Area UA 2�v cvrizts 214+4- 90,11 1-ilb 161.41 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 R3 SHGC Calculation ENV-SHGC 2012 Washing;ofi Sate Enerzty Code Compliance Forr.+c f^. -r^--•--- ^,;ouo R1, and > 3 story R2 & R3 Re.,sea June 2013 P rosea Address V . ' i u i; p t,• Date 1.1,1,..1.:- Fenestration Area as % gross exterior wail area e ilProp Max.Target or Building Department Use Skylight Area as % gross exterior roof area 14 / Prop �'� Max.Target To comply the Proposed total SHGC x A for all fenestration (vertical & skylights) shall not exceed Target total SHGC x A. Skylights Proposed SHGC Provide SHGC source (NFRC or default), page/plan # of detail & iD SHGC x Area (A) = SHGC x fi Target SHGC SHGC x Area (A) = SHGC x A ID: ID: ID: ID: I0: ! I SHGC set occ. Note: Compliance is based upon combined skylight and Totals vertical fenestration performance. Totals All Non -North Vertical Fenestration+ Proposed SHGC Provide SHGC source (NFRC or default), page/plan # PF SHGC* x Area (A) = SHGC x P of detail and ID ID: ID: ID: ID: ID: ID: ID: ID: ID: ID: 0 ' 0 1 0 0 0 i 0 ' 0 0 1 0 0 r Target SHGC ++ PF SHGC x Area (A) = SHGC x A Category PF < 0.2 0.40 0.25PF<0.5, 0.48 PF a 0.5 1 0.64 ++ If projection factor (PF) credits are applied to the proposed design, Target SHGC will sum fenestration area by PF category. + If projection factor credit is applied, then vertical fenestration must be entered in the correct table according to orientation. If credit is not applied then all vertical fenestration can be entered in either table. " Note: Fenestration that separates conditioned space from a non -conditioned or semi -conditioned space shall be listed here with a proposed SHGC equal to the target value. Totals Totals North Vertical Fenestration+ Proposed SHI Provide SHGC source (NFRC or default), page/plan # PF++ SHGC' x Area (A) = SHGC x P of detail and ID Target SHGC++ PF SHGC x Area (A) = SHGC x A Category ID: ID: ID: ID: ID: ID: ° :D,4; rii ; (0M 0.40 • 0 0 0 0 , PF < 0.2 0.40 0.25PF<0.5 0.44 (b'4 PF 0.5 i 0.48 ++ If projection factor (PF) credits are applied to the proposed design, Target SHGC will sum fenestration area by PF category. North Total To comply proposed total SHGC x A shell not exceed Target total SHGC x A. l-11 (454 Grand Total Area SHGC x A l (44 - Area SHGC x A Grand ti 41 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 R3 Perm lr 11C41U1@ ©UIJgVIrJOM ,2012 Washington State Enerav Cotta > 3 story R2 & R3 itriZ eeiti4 kve 4,b- 4,Liirrt 11..e Project Address Reamer) June 2013 Date l r `3 . I, The following_information is necessary to check a building permit application for Compliance with the building envelope requirements in the Washingtontate Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Information Required Location on Plans Building Department Notes SCOPE (Section C101) C101.5.2 Low energy spaces Low energy (unconditioned) spaces identified on plans C101.5.2.1 / C402.1.4 Semi -heated spaces Semi -heated spaces identified on plans C402.5 / 0402.6 Welk -In and refrigerated warehouse Coolers and Cooler and freezer spaces identified on plans C101.4.8 Mixed occupancy Spaces with different occupancy requirements identified on plans l,fa� 0101.4.4 / C101.4.5 Change in occupancy/space Existing building spaces undergoing change identified on plans ENVELOPE PROVISIONS C303.1 Insulation identification Identification mark to be applied to all insulation materials C303.1.3 1 C402.4.3 Fenestration product ratir Fenestration products labeled with rated U -factor, SHGC, VT, leakage rating General installation Indicate installation method, densities and clearances to achieve intended R -value of all Insulation nheterials C402.2.1 Roof assembly insulation Indicate R -value on roof sections for attics and other roofs; Indicate clearances for attic insulation; Indicate baffles if eave vents installed; Indicate face stapling of faced batts C402.2.3 Above/below grade wall insulation Indicate R -value and framing material on wall sections; Indicate face stapling of faced baths; Indicate above grade exterior insulation Is protected; Indicate mass of masonry walls if mass wall claimed Indicate loose -fill core insulation for masonry walls es necessary Indicate frequency of grouted cores and bond beams as necessary C402.5 / C402.6 Walk -In and refrigerated warehouse coolers and freezer insulation Indicate R -values for walls, ceilings, doors and floors In sections C402.2.7 Opaque doors (< 50% glazing) Indicate rated U -factor (swinging) or R -value (roll-up/sliding) on wall sections C402.2.5 Floor over outdoor or unconditioned space Insulation Indicate R -value on floor sections; Indicate substantial contact with surface; Indicate that insulation does not block airflow through foundation vents. C402.2.6 Slab -on -grade floor insulation Indicate R -value on wall section or foundation detail; Indicate slab insulation extends down vertically required distance from top; Indicate above grade exterior insulation is protected C402.2.6 Radiantly heated slab -ors grade floor insulation Indicate R -value on wall section or foundation detail: Indicate slab insulation to full slab depth and under entire stab; Indicate above grade exterior Insulation is protected C402.2.8 Thermal radiation system Indicate insulation of panels, U-bend/headers & floor structure is min. R-3.5 C402.3.1 Vertical fenestration maxi Provide calculation of vertical fenestration area as % of gross wall area WAC Lir C402.3.1.2 SkytigM maximum area Provide calculation of skylight area as % of gross roof area '2-, Chap 2 Def. Daylighting zone Provide calculation of % of overall conditioned floor area in daylight zone Y C402.3.3 C402.3.3 / C402.3.3.1 U -factors and SHGC for vertical fenestration, glazed entrance doors and skylights Indicate U -factors and SHGC values in fenestration schedules; Provide area -weighted calculations as necessary; Indicate if values are NFRC or default, if default then specify frame type, glazing layers, gapwidth, low -e coatings, gas filling Permanent shading devices Provide projection factor calculations for North and Non -North orientations AIR LEAKAGE iir C402.4.1.2.4Air barrier materials Indicate ASTM E2178 rated materials used to provide air barrier on plans {' 7 4/j, C402.4.1.1 / C402.4.2 C402.4.3 / C402.4.4 Air barrier construction and sealing Fenestration, door and access opening leakage Indicate location of continuous air barrier on plans; Provide details for all joints, transitions in materials, penetrations in air barrier and note method of sealing (caulked, Basketed. or other approved method) -fit Indicate air leakage rating and/or method of sealing for all fenestration, doors and access openings In schedules C402.4.8 Recessed lighting fixtures Indicate IC rating of fixtures in lighting equipment schedule; Indicate method of sealing between housing and wall or ceiling in plans T./ C402.4.5.1 IgA' Stairway and shalt vents Indicate locations of all stairway and shaft vents; Provide leakage rating of motorized dampers In equipment schedules C402.4.5.2 Outdoor air Intakes and exhausts Indicate locations of alt outside air Intakes end exhausts; Provide leakage rating of dampers and Identify whether motorized or gravity in equipment schedules C402.4.6 Loading dock seals Indicate weatherseal at cargo and loading dock doors C402.4.7 Vestibules Indicate locations end dimensions of vestibules in plana; For unconditioned vestibies, indicate which wall assembly (interior or exterior) insulated to exterior wall requirements 1C402.4.1.2.lAIr barrier building test Indicate air barter test method conducted In accordance with ASTM E779; • • Joanna Spencer From: Todd Reedy Sent: Thursday, November 14, 2013 11:21 AM To: Joanna Spencer Subject: RE: Mastercraft 11 @ 12628 Interurban Ave S D13-0349 Hello Joanna, I'm happy to report that 12628 Interurban is current on backflow preventer installation and testing. Have a great day, Todd From: Joanna Spencer Sent: Thursday, November 14, 2013 10:29 AM To: Todd Reedy Subject: Mastercraft 11 @ 12628 Interurban Ave S D13-0349 Good Morning Todd, Are their backflows current? Joanna 1 Dr5-0s49 • Qop PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-0349 DATE: 11-13-13 PROJECT NAME: MASTERCRAFT SITE ADDRESS: 12628 INTERURBAN AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: ad"inNicron Public Worl s (3 )11-10/wi /4 Fire Prevention Planning Div' ion Structural n Permit Coordinator )1 -0 -f -f3 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-14-13 Complete Comments: isz Incomplete n Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 3 Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12-12-13 Approved n Approved with Conditions X Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 BOYCE CONSTRUCTION INC • Washington State Department of V,Lab©r & Industries • Page 1 of 2 BOYCE CONSTRUCTION INC Owner or tradesperson BOWELL, ROBERT Principals BOWELL, ROBERT Doing business as BOYCE CONSTRUCTION INC WA UBI No. 601 538 339 270 S HANFORD ST 109 SEATTLE, WA98134 206-264-8085 KING, County Business type Corporation Governing persons ROBERTABOWELL License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. BOYCECI066QQ Effective — expiration 11/18/1994 — 01/21/2014 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 178017C Received by L&I 12/07/2001 Insurance Nationwide Mutual Ins Co Policy no. AC PACT07524265684 Received by L&I 10/04/2013 Savings No savings accounts during the previous 6 year period. Active. Meets current requirements. $12,000.00 Effective date 11/18/2001 $1,000,000.00 Effective date 11/18/2013 Expiration date 11/18/2014 httns://secure.lni.wa.Qov/verify/Detail.aspx?UBI=601538339&LIC=BOYCECI066QQ&S... 12/13/2013 viiNirr MAP SEPARATE PERMIT REQUIRED FOR Di Mechanical 'ttl Electrical tPlumbing Gas Piping City of Tukwila Et.w nl.NG DIVISION LEGAL DESCIRIPTION I•Omat Tifg ,61030291)01,„- MOM. COBTAIND I 7 Alit01-icrii Q Li;11 DESCRIFT10•10 friii3Ott VDU PORTEc C,C. LEWI boximorr- oTATH :Er 3i7 .4KTTot 1.0 g1)44.13611XP'2:. NOM RIME4 1,ZASti !ad!! :Km WM, VESCAZ13:= AS fttaiNat ryr PolOT VM* :t wrsiorge or 92.0L5 tO574tIM.,vt,p./Kft, by !11 _'TU A, 031011 ',ON THE " ' tRENT,ON h3144'eir=t1• 2P O4 17A1FT104 5AX.07POZOMV,V•10% tEM. ,Atmcerpta .'4•1/ ,1400 PIT tAST Mb 20 -1116T , 011004 1170.4:Y1712110- 21:tet'm hT1-41,1M3111:::::trtt41'- 1041"4111: 1230 714Eirr .'1"EfICEE4NOTIII7r k -0u • :-F*Ei-* , . , AND PARALLEL Win Ti ;A' TEE: 1111 A.:011;r4cpc' ,301gs1:19-7,9„:1-7: iew ELTR'ag • 11403124/24T 11,T,VBEI AIM A . PTT)17141k143111 1•110AO, 1144p ;LIVE% grrfilt1998446P24fertsY/1:-DUE261A14"CtE. 091,36, riasTARCE or 5; rem.W tHE Titni "- :17013aa OF IBEGINNZtiG; _ - VENCE SOME 814",to Flog' Oft A. ::gr59,6 .r557.1 TC NON= -$9.°221',311, EAST A. VZOTA.VOI 'THENCE NORTII. 1:11,51.1!31110 WET 14 Kfiltikkik .ar 344 FEET, . .110R. -Alf( IstitS) to TEE LEFT 07 ritAt.134;magit 17441P. T.IFT, BAT* faEINO A,LSO THE Ito 114egicksor OF C. . tanS-110M;(41 ttikr24; 1122121taCV167414-2,212SITIALbreLartlitX14, Lraitt t:4F TRAVMS24qfEZP°F.T82'ESWitid11131117111rISLI MVP 'Ct sant- 000•38.-• FARM DiiO4,OE r,iy io FEW,' MOIRE OR 70.11a5S! VIM POINT OF 13rit-poinn; !AirAltS THt OteTutwir.tA, de#NTt,or. V4 , - . REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions Will require a new plan submittal and may include additional plan review lees. Tx or REVIEWED FOR CODE COMPLIANCE APPROVED NOV 27 2013 City of Tuwa BUILDING DIVVSION SITE AND !BUILDING STATISTICS BUILDING CODE: 2012 IBC UJ/ WA STATE AMENDMENTS ZONING: M-2 BUILDING AREA: 20,625 SF SITE AREA: 10.1 ACRES ASSESSOR IF'ARCEL NUMBER: 0004800003 TENANT SPACE: OVERALL AREA: 0,9413 SF WAIO,E1-10U5E: 5,00 5F OFFICE (NE): 1,158 SF AREA OF ttIOIRK IN SP. TYPE OF CONSTRUCTION: V-15. SPRINKLERED OCCUPANCY: 5, 5-1 AREA CALCULATION: 3 SIDES OVER 20' B.9000 SF. SI 2 e000 !BUILDING IS 1-1A6,0VER 60' COMMON YARD ON ALL 5IDE5, THEREFORE BUILDING 15 UNLIMITED IN AREA PER SECTION 501 SCOPE OF WORK TO CONSTRUCT NEUJ SINGLE STORY OFFICE TO INCLUDE NON-BEARING WALLS, NEW SUSP. CEILING, NEUJ RESTROOMS, NEW EXTERIOR STOREFRONT REPLACING Exi5TING, AND NEW DEMISING WALL. FILE COPY Permit No. TA 77---0;1-0 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field • • and Is acknowledged: By Date aty Of lbkwila BUILDING DIVISION b13%.031-1/ RFCEJVF,, NOV 1 4 2013 PUBLIC WORKS RECEIVED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER LLJ 7 CA LJ 0 DESCRIPTION SUBMIT FOR PE -1I1 11011110011M16 SD -1 C:\Documents and Settings1All Users\Documents\CAD1200210225 FIREERTulwvila Commerce ParldBuilding C\MASTERCRAFT MIDDLE 10-23-13\cd's 11-12-13\SD1.dWg, SD -1, 11/12/2013 9:23:19 PM 25' 50' 50' 225' 50' 50' 25' 25' CONFERENCE 12'X24' RECEPTION, UUAITING OFFICE 10'X12' OFFICE 1O'X12' FILES SEE TEANT SPACE BLOW UP SHEET T-2 H OPEN OFFICE P 1GUBE 8.'X8.1 r T ICE 12'X10' ADA CONFERENCE 10'X15' CUBE // 8'X8' RECEPTION NEW FULL HEIGHT DEMISING WALL EXISTING FULL HEIGHT DEMISING UJALL r I CUBE 1 CUBE 8.1X8' UJAREHOUSE EXISTING No UJORI< REVIEWED FOR CODE COMPLIANCE APPROVED NO4 2 7 2013 6) City of Tukwila BUILDING DIVISION WAREHOUSE EXISTING NO WORK n r 12628 TOTAL SF 8,108 SF UJ/ LOAD OFFICE SF 1,961 SF MNAN THIS 12,28 SUIT 120 TOTAL 5F 6,848 SF UJ/ LOA OFFICE SF 1,158 5F 225' 12628 TOTAL 5F 5,669 5F UJ/ LOAD OFFICE 5F 1,24 SF FLOOR FLAN: OVERALL 5 4LE: 1/8".1'-0" 724..) L-17 RECEIVED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER H C.) O DRAWN BY M 0 1 N 1 6 -DESCRIPTION- 0 IL N ro) o) co 14.) co I *C4 0 0 4.11 0 .ty a% C:\Documents and SettingslAll Users\Documents\CAD1200210225 RREEF\Tukwila Commerce Parlc\Building C\MA$TERCRAFT MIDDLE 1Q-23-13\cd's 11-12-131T-1 BLDG C CD'S 11-12-13.dwc, T-1 OVERALL, 11/12/2013 9:24:01 PM x RECESSED CAN WITH BATTERY E3ACK UP - PRIMARY DAYLIGHT ZONE EQUALS THE HEAD HEI HT OF THE EXTERIOR VERTICAL GLAZING (S'), WITH SECO DARY DAYLIGHT ZONE EQUAL TO 2X THE HEIGHT OF VE TICAL GLAZING (16') GYP BD CEILING WI' WITH 5/8" GYP BD, I• SWITCH THE EXHAUS OUTSIDE. CEILING HEIGHT TO BE 91AFF WITH SECOND LOOK TILES, R-49 BATT INSULATION AND IC RATED FIXTURES H 611X20GA. AT 24"O.C. STEEL JOISTS, -49 ISULATION AT 9' AFF FAN WITH LIGHTS. EXHAUST FAN TO G'rP BD CEILING WI H 6"X20GA. AT 24"0.C. STEEL JOISTS, WITH 5/8" GYP BD, ITH RESILIENT FURRING CHANNELS AND SOUND INSULA ION AT 9' A1, TIN G ENEe'v ALLOWABLE WATTS PER SF OFFICE: R5FLECTEID CEILING PLAN SCALE: 1/8"=1'-0" AREAS: GROSS OVERALL = 6,848 SF OFFICE = 1,158 SF. COD.: .9I X 1,158=1,054 WATTS INSTALLED: FIXTURES ARE TO BE IC RATED 2'X4' PARABOLIC FLUORESCENT, 3 TUBE T8 6 88 WATTS: 6X88: 528 WATTS 2'X4' PARABOLIC FLUORESCENT, 2 TUBE T8 e 66 WATTS: 1X66: 462 WATTS COMPACT FLUORESCENT 12 WATT : 5X12: 60 WATTS TOTAL WATTS INSTALLED : 1,050 WATTS ID4YL I =T CONTROL: PER SECTION 1513.3 EXCEPTION 4.b ROOMS SMALLER THAN 300 SF ARE EXEMPT FROM THE DAYLIGHTING CONTROL WITH OCCUPANCY SENSORS CONTROLS. IN DAYLIGHTED ZONES, PROVIDE INDIVIDUAL LIGHTING CONTROLS WITH DUAL LEVEL SWITCHING OR AUTOMATIC DAYLIGHT SENSING CONTROLS. SWITCHES SHALL HAVE MAX. 80% OF A 20 AMP CIRCUIT. ,ALL TYPES: 1. EXTERIOR FURRING: CONTINUOUS R-1.5 RIGID INSULATION OVER TILT -UP CONCRETE PANELS, R-21 BATT INSULATION WITH VAPOR BARRIER, 6" STEEL STUDS X 25 GA AT 24" O.C. VAPOR BARRIER AND 5/8" GYP D. TO 6" ABOVE CEILING (U:O.XXX) 2. INTERIOR TO CEILING: 3 5/8" X 25 GA TO CEILING WITH 5/8" GYP BD EACH SIDE (51 MEANS SOUND INSULATED) 3. FULL HEIGHT PERIMETER: 6" X 18 GA AT 24" O.C. TO ROOF DECK WITH DEFLECTION TRACK, R-21 INSULATION, VAPOR BARRIER ON WARM SIDE, 5%8" GYP BD EACH SIDE (WATER PROOF IN RESTROOM) RIGID INSULATION ON OUTSIDE R:1.5.(U:0XXX) 4. RESTROOM WALL: 3 5/8"X20GA ,4T 24" O.C. TO CEILING WITH SOUND BATT INSULATION, 5/8" GYP BD EACH SIDE (WATER RESISTANT IN RESTROOM) 5. PLUMBING WALL: S" TRACK WITH 3 5/8" X 20 GA AT 24" O.C. STAGGERED 70 CEILING WITH SOUND BATT INSULATION, 5/8" GYP BD EACH SIDE WATER RESISTANT. 6. DEMISING WALL: 6"X1804 a 24" O.C. TO ROOF STRUCTURE WITH DEFLECTION TRACK, 5/8" GYP BD EACH SIDE. 1. COMPRESSOR± 6" X 20 GA STL STUD AT 24" 0.0: TO CIELING ABOVE AT 91WITH RESILIENT FURRING CHANNELS ON INSIDE, SOUND INSULATE, 5/S" GYP BD EACH SIDE ROO SCI [ED 1-4 FLOOR: NEW CARPET BASE : NEW RUBBER BASE WALLS: NEW PAINT OVER GYP D. (EE) CEILING: NEUJ SUSPENDED ACOUSTICAL +9'AFF 5,6 FLOOR: NEW SHEET VINYL BASE: NEW COVED SHEET VINYL +6" WALLS: NEUJ 4' PLASTIC LAMINATE WAINSCOT GYP BD PAINTED ABOVE (SGE) CEILING: NEW GYP BID PAINTED (SGE) +9'AFF 7 FLOOR: SEALED CONCRETE BASE: NONE WALLS: PAINTED CONCRETE AND GYP BD (F) CEILING: EXPOSED CONSTRUCTION 8. FLOOR: SEALED CONCRETE BASE: NONE WALLS: GYP BD (FLAT ) CLG. GYP BD (+9) (FLAT) 4 50' 25' OFFICE TO BE HEATED AND VENTILATED, HEAT VIA GAS EXISTING H.C. ACCESS FROM EXISTING CONTINUOUS SIDEWALK 52' 21' NEUJ COUNTER SEE SNT T-4 DOOR SCI I D UL - : (NEUJ HARDWARE TO BE LEVER HANDLED) NELU 3'-0"X7'-0" ALUMINUM STOREFRONT WITH 1" INSULATED SAFETY GLAZING, CLOSER, THRESHOLD MAX. 1/2", OFFSET PULL AND PUSH, OFFSET PIVOT WITH INSIDE STOP, LOCK SET, SIGN "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS", FULL TIGHT WEATHERSTRIP. (U=038) 2,3 NELU 3'-0"X8'-0" SC OAK DOOR AND FRAME, 2 PAIR BUTTS, LOCKSET, WALL 4 STOP AND SILENCERS 5,1 NEW 3'-0"X8'-0" SC OAK DOOR AND FRAME, 2 PAIR BUTTS, PRIVACY LOCKSET, HINGE CLOSER, WALL STOP SILENCERS(WEATHERSTRIP ON DOOR 8 WITH THRESHOLD) (U=0.50) 6,8 NEW 31-01X81-0" SC OAK DOOR AND FRAME, 2 PAIR BUTTS, LOCKSET, CLOSER, THRESHOLD, WEATHERSTRIP (U:0.50) 9.. NEW 3'-0" X 1'-0" HOOLW METAL DOOR AND FRAME (PAINTED), SOUND INSULATED,1 1/2 PAIR BUTTS, THRESHOLD, WEATHERSTRIP, WALL STOP E1,3,4 EXISTING OVERHEAD ON GRADE DOORS TO BE REFURBISHED AND ADD WEATHERSTRIP E2 EXISTING HOLLOW METAL 3'Xl' DOORS AND FRAMES. REFURBISH, CHANGE LOCKS t0 LEVER HANDLES .1,1N170,4 Scl I -DLL: A. NEU) 2'-0" X 1'-6" AT +6" AFF WOOD FRAME TO MATCH DOOR, GLAZING TO BE 1/4"CLEAR TEMPERED SAFETY GLAZING. UJI NOT USED U)2 REMOVE EXISTING SINGLE GLAZED STOREFRONT AND REPLACE WITH ALUMINUM THERMAL BROKEN FRAMES WITH 1" CLEAR INSULATED GLAZING WITH U:038 AND SHGC OF 0.40. PROVIDE SAFETY GLAZING AS REQURED BY CODE NEXT TO DOORS AND ALONG WALKING SURFACES. 1311 CV OPEN OFFICE 'LUNCH 2 140SF01/15=9 OCC 14'-11" 12',9" 12' OFFICE OCCUPANCY 28 2 OFFICE F205F61/100 :1.2 OCC 618SF61/100 :6.2 OCC 1 CONFERENCE 1S05FQ1/15:12 OCC SEE SHEET T-4 FOR BLOW UP NEW UTILITY SINK I i 4, I I I 61_9" REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION 5,6905F61/560 :11 OCC WAREHOUSE SEMI HEATED VIA GAS MAX. 8 BTUH PER SF THERMOSTAT AT UNITS WITH TEMP SET A MAX. 44d. EXISTING ROOF HAS R-21.3 RIGID NEW FULL HEIGHT DEMISING WALL 1' 22'-1" EXIT TRAVEL DISTANCE 15 99 LF 4 SINGLE EXIT • • .I I I I I I •I I ••I • • • • WEATHER PROOFING: 1. CAULK AND SEAL ALL TRANSTIONS FROM DISSIMILAR METALS, CAULK ALL WINDOW FRAMES BOTH INSIDE AND OUT. 2. SEAL ALL OUTLETS IN OUTSIDE FRAME WALLS 3. EXISTING ROOF HAS R-213 RIGID ON TOP OF PLYUJOOD. (U= 0.041) NO CHANGES FLOOR PLAN: • • • • EXISTING FULL HEIGHT DEMISING WALL 1 b 13 SCALE: 1/8"=1'-0" AREAS: GROSS OVERALL : 6,848 S.F. OFFICE : 1,158 S.F. EXITING: OFFICE 1,158SF: 28 OCCUPANTS, 1 EXIT REQUIRED WAREHOUSE 5,69001/500=11 OCCUPANTS,1 EXIT REQUIRED TRAVEL DISTANCE UNDER 100 LF 3L4C7 RECEIVED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER 0 0 0 DRAWN BY 0 N 6 O m 1 in Q >- m 0 W w w U < DESCRIPTION 11 M CO 03 11 00 N N 46. co :!C OADocdments and Settings\All Users\Documents\CAD12002\0225 RREEF\Tukwila Commerce Park\Building CIMASTERCRAFT MIDDLE 10-23-13\cd's 11 -12 -MT -1 BLDG C CD'S 11-12-13.dwg, T-2 FLOOR PLAN, 11/12/2013 9:2418 PM 5m' 15' e REVIEWED FOR CODE COMPLIANCE R YED CE APP 140V 2 7 2013 City of Tukwila BUILDING DIVISION 0- FLOOR 'LAN: POWER 4 PHONE DATA SCALE: 1/S"=1'-@" AREAS: GROSS OVERALL = 6,84S SF OFFICE = 1,I5S SF. DUPLEX OUTLET 4 FLEX OUTLET 0 PNONE/DATA OUTLET WITH MUD RING AND PULL STRING FOR TENANTS WIRING b t3-a3yq ===.;= RECEIVED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER CCI N 1 6 01 te) 00 00 r') I * Cs1 u8 NDN. H 7) E:4 L -T-1 z� z 1.4 Q W raq0 E-1 z 0 T- 3 C:1Documents and Settings\AII Users\Pocuments\CAD12002\0225 RREEF\Tukwila Commerce Park\Building C\MASTERCRAFT MIDDLE 10-23-13\cd's 11-12-13\T-1 BLDG C CD'S 11-1213.dvyg, T-3 POWER, 11/12/2013 9:24:34 PM C4 • SPACER BAR, OR OTHER SUITABLE SYSTEM, TO KEEP PERIMETER COMPONENTS FROM SPREADING APART. CROSS RUNNER MAIN RUNNER N0TE5: CABINETS ARE TO BE FLUSH OVERLAY, PLASTIC LAMINATE WITH KORTRON INTERIOR, PLASTIC LAMINATE TOP WITH 2" EDGE AND 4" BACK SPLASH: HARDWARE TO BE CONCEALED WINCES, US 26D WIRE PULLS AND SILENCERS ON, DOORS AND DRAWERS. SHELVING TO BE ADJUSTABLE t _==__=Z=N=====W_ \ \. / ,-.\.�' \ / • / \ 6'-0NTS j, PLASTIC LAMINATE UPPER CABINET WITH INTERIOR ADJ. SHELVING REFER BY TENANT 4" P.LAM BACKSP'ASH SINK WITH GOOSE NECK i=AUCET PLASTIC LAMINATE BASE CAk INET WITH INTERIOR ADJ. SHELVING OPEN BASE UNDER / SINK FOR ADA. WRAP PIPES LUNCH G4E31NET ELEV4TION SCALE: I/4"=1'-0" 3/4'I/MIN. At UN -ATTACHED WALLS MIN 2" ,ALL ANGLE NOTE: ATTACH CEILING AND GRID TO WALL ANGLE (MOULDING) AT TWO ADJACENT WALLS VIA POP RIVETS. 4+12 GA. WIRES WITHIN 2" OF CROSS TEE CONNECTION ARRANGED AT S0' FROM EACH OTHER AND AT AN ANGLE NOT EXCEEDING 45°. LOCATE RESTRAINT PANELS AT 12' O.C. IN EACH DIRECTION AND WITHIN 6' OF EACH WALL. NOTES:. NOTE: SUSPENSION WIRES TO BE 12 GAGE AT 4' O.C. W/ ATTACHMENT DEVICES CAPABLE OF SUPPORTING 100 POUNDS. HANGER 4 PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 UNLESS COUNTER SLOPING WIRES ARE PROVIDED 1) MAIN BEAMS TEES AND CROSS TEES MUST BE HEAVY DUTY W/ CONNECTION STRENGTHS OF 100 POUNDS IN COMPRESSION 4 TENSION. 2) OILING AREAS GREATER THAN 1000 SF MUST HAVE LATERAL FORCE BRACING VIA DIAGONAL SPLAY WIRES, LIMITING MOVEMENT TO LESS THAN 1/4" AT POINT OF ATTACHMENT. 3) LIGHT FIXTURES TO BE POSITIVELY ATTACHE TO MAIN AND CROSS TEES. AND IF OVER 56, MUST BE INDEPENDENTLY SUPPORTED. 4) PARTITIONS GREATER THAN 6' TALL NEED INDEPENDENT BRACING VIA SPLAY UJIRE5 (SEPARATE PROM ANY 011-IER WIRES). PARTITIONS 6' OR LESS NO ATTACHMENT 15 REQUIRED. 5) SPRINKLER HEAD PENETRATIONS MUST HAVE 2" OVERSIZED TRIM TO ALLOW 1" MOVEMENT IN ALL DIRECTIONS. 6) MANUFACTURER CERTIFICATION OF COMPONENT PERFOWANCE AND PERIODIC SPECIAL INSPECTION OF ANCHOR SYSTEM 15 REQUIRED. 1) FOR CEILING AREAS EXCEEDING 2500 SF, A SEISMIC SEPERATION JOINT OR FULL 1 -EIGHT WALL PARTITION THAT BREAKS THE CEILING SHALL BE PROVIDED. 6) ALL CROSS TEES S, TALL BE CAPABLE OF CARRYING THE DESIGN LOAD WITHOUT EXCEEDING DEFLECTION EQUAL TO Y360 OF ITS SPAN. 9) ALL WIRE TIES ARE TO BE THREE TIGHT TURNS AROUND ITSELF WITHIN 3 INCH. FZE5TRAINED CEILING DETAILS (MEETS IBC 2012 GEC 806 AND ASTM C 635 ASTM C 636 AND ASCE 1-02) SCALE 60"X56" CLEAR SPACE AT TOILET 30"X48" CLEAR SPACE OUTSIDE DOOR SWING 5' DIA TURNING CIRCLE • -I'-0° %/ T..0" I3LOUJ UP RES - ROOMS SCALE: 1/4"=1-0" PAINTED GYP BD WALL •,STIC LAM WAINSCOT MIRROR COVED BASE ELEVATION REVERSED 01 N • 1/4" MIRROR PAINTED GYP BD WALL PLASTIC LAM WAINSCOT 5'-0" / HORIZONTAL GRAB BAR j VERTICAL GRAB BAR �coveQ ease P.LAM COUNTER ELEVATION REVERSED m • PAINTED GYP BD WALL PLASTIC LAM WAINSCOT TYPES R-213 INSULATION OVERI PLYWOOD +1 I/2" SPACE GYP.BD, TO GYP. BD. EA SIDE ROOF STRUCTURE PURLIN 6" DEEP LEG TRACK ATTACH TO G.L.B. W/3 1 5(8" SCREWS "6 2'-0" O.C. (DEEP LEG 15 3") STUDS PER SCHEDULE NOT ATTACHED TO TRACK BUT LAPPED UP INSIDE I". GYP. P. ATTACHED TO STUD -NOT TO GLIB OR TRACK- LAP 1 1/2" ON GLB NOTE: 1) SOUND INSULATE WALL TO 10' AT OFFICE LOCATIONS 2) FOAM ANY UJALL PENETRATIONS FOR SOUND (ELEC., TELEPHONE, ETC.) 3) CAULK GYP. BD. TO CONCRETE SLAB. NEAR DETAIL SCALE: 11/2" = 1'-0" 22" WIDE SOUND BATTS EA. SIDE WALL SOUND WALL (51) ittildit 9 1■■o■111111■11■�■11■ne�/ 111111111111111111111111111 1� SECTION FOR WALLS GREATER THAN 81- 0" IN WIDTH WITHOUT ASI INTERSECTING WALL, PROVIDE 12ga. WIRES SPLAYED 4 45° TO AN EYE SCREW 0 ROOF AND TOP OF IIJALL ATTACH BOTTOM TRACK TO CONC. FLOOR W/ HILTI,1" EMBED, POWDER DRIVEN ANCHORS AT 24" O.C. 10.010ONNI0.441, WALL. SECTION SCALE: 1-1/2" = 1'-0" VERTICAL GRAB BAR HO. ZONTAL GRAB BAR TOILET PAPER HOLDER COVED BASE PAINTED GYP BD WALL PLASTIC LAM WAINSCOT COPED BASE ELEVATION REVERSED RST OOM6 ELFV 4TION5 SCALE: 1/4"=1I-6" NOTES: CONT. METAL TRIM. 5/8" GYP. P. ACOUSTICAL BLANKET e SOUND WALL. CAULK GYP. BD. TO FLOOR a ALL SOUND AND INSUL. WALLS REvsbv4E.0 FOR ODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila UILDING DIVISION 1. ALL TOILET ACCESSORIES TO BE PLACED +40" AFF TO OPERATING PORTION OF ACCESSORY 2. INSULATE THE H0T, COW AND' WASTE ON SINKS 3. SET TOILET SUCH THAT THE HANDLE 15 TO THE OPEN SIDE OF COMPARTMENT 4: GRAB BARS ARE 11/2" DIAM STAINLESS STEEL, KNURLED AS REQUIRED TO MEET CODE,SET 1 1/2" OFF THE WALL/PARTITION SECTION TYPICAL STUD IUALL GLAZING TAPE STANDARD WOOD STOPS n'r:eo 1111111 411 i1 ►%� MU 11/11 ►1 eea�► t 1/4" LAMINATED OR TEMPERED SAFEEY GLAZING OAK FRAME ELITE/DOO SCALE: 1-1/2" = 1'-0" MIL STUD (SEE SCHEDULE) 2x IUOO 3 BLOCKING 11/2" x OAK JAMB 5/S" x OAK STOP SMOKE SEAL SOLID CORE WOOD DOOR W/ OAK VENEER 5/8" GYP D. EACH SIDE WOOD FRAME DETAIL SCALE: 1-1/2" = 1'-0" FLOOR. FINISH SEE 1=INISH SCHEDULE LAMINATED OR TEMPERED SAFETY GLAZING TYPICAL 11.1001) JAMB /SILL AND WOOD STOPS BUILDING PAPER OR VISQUEEN OAK RELITE SILLb vs; -23.1 SCALE: 1-1/2" = 1'-0 nuunuuuunn r:;,ir _. � me�mamuu TYPICAL TOP OF WALL BRACING DETAIL I/4" SHIM AT ALL GRID TO WALL CONNECTIONS TYPICAL TOP TRACK FAINTED BLACK TYPICAL CEILING TO GYP. D. NOTCH TYPICAL WOOD JAMB AND STOPPED IN GLAZING RELITE I=11=,4h SCALE: 1-1/2" = 1'-0" 1171 l'- 0" NTS SECTION U 141 0 E4 a Q 1 4 8 Q m 0 w w 0 0 0 0 SECTION W = Q . 0., ILL. RECEIVED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER SECTION 6CtION rfledo 0 1 ad Cc\Documents and Settings\Ail Users\Documents\CAD12002\0225 RREEF\Tukwila Commerce Park\Buildina C\MASTERCRAFT MIDDI-F (lwn T4 11/17/7f1110.9g•mq pM 174" • cs9 i•()J t _'c -O" X2' X Q 61 N 0 N - 1 — � COVED BASE ELEVATION REVERSED 01 N • 1/4" MIRROR PAINTED GYP BD WALL PLASTIC LAM WAINSCOT 5'-0" / HORIZONTAL GRAB BAR j VERTICAL GRAB BAR �coveQ ease P.LAM COUNTER ELEVATION REVERSED m • PAINTED GYP BD WALL PLASTIC LAM WAINSCOT TYPES R-213 INSULATION OVERI PLYWOOD +1 I/2" SPACE GYP.BD, TO GYP. BD. EA SIDE ROOF STRUCTURE PURLIN 6" DEEP LEG TRACK ATTACH TO G.L.B. W/3 1 5(8" SCREWS "6 2'-0" O.C. (DEEP LEG 15 3") STUDS PER SCHEDULE NOT ATTACHED TO TRACK BUT LAPPED UP INSIDE I". GYP. P. ATTACHED TO STUD -NOT TO GLIB OR TRACK- LAP 1 1/2" ON GLB NOTE: 1) SOUND INSULATE WALL TO 10' AT OFFICE LOCATIONS 2) FOAM ANY UJALL PENETRATIONS FOR SOUND (ELEC., TELEPHONE, ETC.) 3) CAULK GYP. BD. TO CONCRETE SLAB. NEAR DETAIL SCALE: 11/2" = 1'-0" 22" WIDE SOUND BATTS EA. SIDE WALL SOUND WALL (51) ittildit 9 1■■o■111111■11■�■11■ne�/ 111111111111111111111111111 1� SECTION FOR WALLS GREATER THAN 81- 0" IN WIDTH WITHOUT ASI INTERSECTING WALL, PROVIDE 12ga. WIRES SPLAYED 4 45° TO AN EYE SCREW 0 ROOF AND TOP OF IIJALL ATTACH BOTTOM TRACK TO CONC. FLOOR W/ HILTI,1" EMBED, POWDER DRIVEN ANCHORS AT 24" O.C. 10.010ONNI0.441, WALL. SECTION SCALE: 1-1/2" = 1'-0" VERTICAL GRAB BAR HO. ZONTAL GRAB BAR TOILET PAPER HOLDER COVED BASE PAINTED GYP BD WALL PLASTIC LAM WAINSCOT COPED BASE ELEVATION REVERSED RST OOM6 ELFV 4TION5 SCALE: 1/4"=1I-6" NOTES: CONT. METAL TRIM. 5/8" GYP. P. ACOUSTICAL BLANKET e SOUND WALL. CAULK GYP. BD. TO FLOOR a ALL SOUND AND INSUL. WALLS REvsbv4E.0 FOR ODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila UILDING DIVISION 1. ALL TOILET ACCESSORIES TO BE PLACED +40" AFF TO OPERATING PORTION OF ACCESSORY 2. INSULATE THE H0T, COW AND' WASTE ON SINKS 3. SET TOILET SUCH THAT THE HANDLE 15 TO THE OPEN SIDE OF COMPARTMENT 4: GRAB BARS ARE 11/2" DIAM STAINLESS STEEL, KNURLED AS REQUIRED TO MEET CODE,SET 1 1/2" OFF THE WALL/PARTITION SECTION TYPICAL STUD IUALL GLAZING TAPE STANDARD WOOD STOPS n'r:eo 1111111 411 i1 ►%� MU 11/11 ►1 eea�► t 1/4" LAMINATED OR TEMPERED SAFEEY GLAZING OAK FRAME ELITE/DOO SCALE: 1-1/2" = 1'-0" MIL STUD (SEE SCHEDULE) 2x IUOO 3 BLOCKING 11/2" x OAK JAMB 5/S" x OAK STOP SMOKE SEAL SOLID CORE WOOD DOOR W/ OAK VENEER 5/8" GYP D. EACH SIDE WOOD FRAME DETAIL SCALE: 1-1/2" = 1'-0" FLOOR. FINISH SEE 1=INISH SCHEDULE LAMINATED OR TEMPERED SAFETY GLAZING TYPICAL 11.1001) JAMB /SILL AND WOOD STOPS BUILDING PAPER OR VISQUEEN OAK RELITE SILLb vs; -23.1 SCALE: 1-1/2" = 1'-0 nuunuuuunn r:;,ir _. � me�mamuu TYPICAL TOP OF WALL BRACING DETAIL I/4" SHIM AT ALL GRID TO WALL CONNECTIONS TYPICAL TOP TRACK FAINTED BLACK TYPICAL CEILING TO GYP. D. NOTCH TYPICAL WOOD JAMB AND STOPPED IN GLAZING RELITE I=11=,4h SCALE: 1-1/2" = 1'-0" 1171 l'- 0" NTS SECTION U 141 0 E4 a Q 1 4 8 Q m 0 w w 0 0 0 0 SECTION W = Q . 0., ILL. RECEIVED CITY OF TUKWILA NOV 1 3 2013 PERMIT CENTER SECTION 6CtION rfledo 0 1 ad Cc\Documents and Settings\Ail Users\Documents\CAD12002\0225 RREEF\Tukwila Commerce Park\Buildina C\MASTERCRAFT MIDDI-F (lwn T4 11/17/7f1110.9g•mq pM