Loading...
HomeMy WebLinkAboutPermit D13-0352 - AIRFIELD BUSINESS CENTER - TENANT IMPROVEMENTSPEC 2 9124 EAST MARGINAL WY S D13-0352 Parcel No: Address: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 5422600150 Permit Number: D13-0352 9124 E MARGINAL WAY S Project Name: SPEC 2 Issue Date: 1/7/2014 Permit Expires On: 7/6/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WOOD MEADOWS LLC PO BOX 654 , KIRKLAND, WA, 98083 DAVID KEHLE 1913 BONAIR DR SW , SEATTLE, WA, 98116 TCL PARTNERS CORPORATION 16000 MILL CREEK BLVD SUITE 1, MILL CREEK, WA, 98012 TCLPAPC919QD Expiration Date: 7/10/2015 Phone: (206) 433-8997 Phone: (425) 316-3500 SELF FUNDED - LOS ARBOLES DESCRIPTION OF WORK: REMOVE EXISTING NON-BEARING WALLS AND EXISTING STOREFRONT, CONSTRUCT NEW 884 SQ FT INTERIOR OFFICE WITH RESTROOMS, INSTALL NEW STOREFRONT, SUSPENDED ACOUSTIC CEILING Project Valuation: $24,300.00 Fees Collected: $962.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: VB Occupancy per IBC: S-1 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: tuff. Date: 1-7- l —I I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agre- the conditions attached to this permit. Signature: " - `l Date: 1.7- Ili Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. • • 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 15: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 19: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 20: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) • • 25: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 26: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 27: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 30: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 31: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 32: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0603 ROOF/CEILING INSUL 0406 SUSPENDED CEILING 0601 WALL INSULATION CITY OF OKWILA Community Development Department Pablle Works Department Permit Center 6300 Southcenter Blvd., .Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 0 3S-..2— Project No, __. _ Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. —Please Print" SITE LOCA'T'ION Site Address:. oil '" I6ign ll.OIL44, Tenant Name: 4e6 PROPERTY,,OWNER Name: aNtii0 NH F{ Address: lo Name: 1 ? /6rg6' 11 js Kieft ve o ppaw City:/,ta� State:WA Address: Po , 2,K . Pltone:n Fax;., l i RLii,isiv Statev. Zipq143City: CONTACT PERSON — person receiving all project communication Name: aNtii0 NH F{ Address: pule Address: lei I VI 11 js Kieft ve o ppaw City:/,ta� State:WA Zip,/k 11 Pltone:n Fax;., l i Email: drt'uiI.e iGENERAL CONTRACTOR INFORMATION Company Name: Address: , Architect Name; 11 js Kieft ve o ppaw Address:VI 1 u City: State: -baa Fax: •„ Ii, _lgeo Ltlertik4y44,�L� 1 Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: !i 'AFplicationaorrrs-A;p!iceiors on Lir.e\2012 App!tcatio-,'Permit Ap;hulion Re:iud • 24.12 d c Revised Febniary;012 King Co Assessor's Tax No.:-�Z�pf7(} ) L'S Suite Number:_ Floor: New Tenant: X Yes ❑..No ARCHITECT OF RECORD Company Nam /�,�' �e: V1.lo L 1 ' jil� , Architect Name; 11 js Kieft ve o ppaw Address:VI 1 u City:'!sitre- State \\ Zip:4E116 Phone:/c6).45 -baa Fax: •„ Ii, _lgeo Ltlertik4y44,�L� 1 Email lm* p ENGINEER OF RECORD Company Name: �,t �''i1�{1c Engineer Name: Address: • • Phone: Fax: Email: LENDER/BOND ISSUED (required for projects S5,000 or greater per RCW 19.27.095) Name: Address: RuLI RV • - City: State: Zip: Page i of 4 Du1t.U11',sr rt;Kablt 1 INFORM ON — 206-431-3670 Valuation of Project (contractor's bid price): S MI10 Describe the scope of work (please provide detailed information): VertNe EX, Lu - ei Ler \\kv2 anit+� . G�C .t'-, " tt'riY II't1262.- errix lzttt Fegtc6*, twstbit, t- pct t" f Justr. Existing Building Valuation: spa Will there be new rack storage? ❑ .... Yes ( ..No if yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 1" Floor Existing Interior Remodel 2'' Floor 3' Floor 74-1cQ e 4 Floors thru Basement Accessory Structure" Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Addition to Existing Structure 4 New Type of Construction per IBC Type of Occupancy per IBC 4 VB PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) `For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: w Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her pritnary residence. Number of Parking Stalls Provided: Standard: 4) NW7 Compact: �'i• Handicap: Will there be a change in use? Yes 0 No If "yes", explain: �l 1 \'� i Qtr FIRE PROTECT1ON/1<IAZARDOUS MATEg1ALS; 'n( Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Vill there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. ;EPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. ,Apr/icariensWorms•Applicatiors On I.inc12012 Applicaricns'Permit Application Revised • 2.7-12 dory ‘;std' February 2012 Page 2 of 4 PERMIT APPLICATION NOT* • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subjt to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitati, 'rhe Building Official may grant one or more extensions ot'time for additional periods not exceeding 90 days each. The extension shall requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINEE) THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY 13Y THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMI: BUILDING OWNE OR IjgbRIZED AGENT: Signature: Print Name: af I Q Le Mailing Address: ri I Ce 991.1610. i Furns•App;kation,OnLine\2012ApplicationaermitApplicaliunAet ed-2-7.12docs :r_ :as•. 17)12 Date: titi ! 7)?7 Day Telephone: 1 cq /)trt' City State zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT ( QUANTITY ( PAID D13-0352 Address: 9124 E MARGINAL WAY S Apn: 5422600150 $584.80 DEVELOPMENT $584.80 PERMIT FEE WASHINGTON STATE SURCHARGE TOTAL FEES PAID BY RECEIPT: R627 R000.322.100.00.00 B640.237.114 $580.30 $4.50 $584.80 Date Paid: Tuesday, January 07, 2014 Paid By: TCL PARTNERS CORPORATION Pay Method: CHECK 020802 Printed: Tuesday, January 07, 2014 11:21 AM 1 of 1 CRWYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $377.20 D13-0352 Address: 9124 E MARGINAL WAY S Apn: 5422600150 377.20 DEVELOPMENT $377.20 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R126 R000.345.830.00.00 $377.20 $377.20 Date Paid: Monday, November 18, 2013 Paid By: DAVID KEHLE Pay Method: CREDIT CARD 025820 Printed: Monday, November 18, 2013 1:25 PM 1 of 1 CRW SYSTEMS #INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. ' CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 D13 -o3, ProjF: (0 2 TYPen `pec /OOf: Acj¢rI 2,Lf E M n 4, r, �( Date Called: Special Instructions: /1---- Date anted: 1....---27111-" .41:11- Requester: ( r) A Phi. c ...scyzaps C Approved per applicable codes. Corrections required prior to appr al. COMMENTS: C___dMn\t?� Inspector Date' n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with. permit INSPECTION NO. PERMIT NO. D 3;-015 CITY OF TUKWILA BUILDING. DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 - Projec�jt: Z . T pe of luspec i :.14 t A dless;Date L iL( ((t7'1q /2...:,i tv 4 L. Called: Special Instructions: - Date Wanted: LI r / 7m�` 7- /4 p,m. Requester: Phone No:. Approved per applicable codes. L..J Corrections required prior to approval. COMMENTS: I j sysaA ,i 4 ,, /iii /A/c/ 14Z /xJ6-0oct/i 'J c) ,Vs7.1/ 4-pp./A:d L3) Cie is Date SPECTION FEE REQUIRED. Prior -to net inspection, :fee must be at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit✓ -' D-3 52. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project S� e 2-- . Type of Inspection: s ,i� EN.v /�e / .t L Addres . q 1 Zq AA -6. A, ,-L_. Date Called Special Instructions: Date Wanted: i a.m. Requester: P1•42?.., eco.'74 (. EJApproved per applicable codes. • El Corrections required prior to approval. COMMENTS: _SJL ec:�i Sr:�G-ter"-ZoLL Ins • ctor: Date (4- 4 REINSPECTION FEE 3EQUIREPrior to.next inspection, fee -must be paid at 6300 Southcenter Blvd.. Suite 100. Call.to schedule reinspection. INSPECTION RECORD Retain a copy p with p ermit L t 3-03 , . INSPECTION NO. _ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila. WA 98188. (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: 5 �f� TypeofInspection: //�, C l/ / �i¢./ su/ j' V Addr ss:. 12 If e-4-5-7-- NO61A/6.6 Date Called: Special Instructions: Date.e_i_ � 7 Requester: Phone No: proved per applicable codes. ElCorrections required prior to approval. COMMENTS: s, Date:•. • . / REINSPECTION FEE REQU RED. Pri • r to next inspection. fee must be eait6at`6300 Southcenter Blvd., Suite 100 Callao schedule reinspection. • H INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: /° *(1 Z Type of,I,nspection: /-i-14s// lam Address: -9 fa ti 04acht/4& Date Called: Special Instructions: Date Wanted: 3_ 3 1-/'f a.m. Fr Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: REINSPECTION FEE REQ IRED. Prior t6 next inspection, fee must be paid at 6300 Southcenter lvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Dr3-o3s �y-F-o.ci y PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Ln !,� L/)/�j �( {ti?'1�'"+ WJI�iS Type of Ins ection: FA, F- nhc,A Address: cj / 2 ,-/ c M� ..5 (AA ./ S. Suite #: Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Y Sprinklers: Y , Date: 5"---C,-/ Lf Fire Alarm: M4 Kv4. I Hood & Duct: /V Monitor: 6 -as a -t. 416 v .- Pre -Fire: Permits: Occupancy Type: S-'D— Inspector: ( Date: 5"---C,-/ Lf Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit L)/3- ()35� , q-5-o�S PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: _ 1f �d souk 1 Type of Inspection: 5P c©ve� Address: cI / a v Suite #: mss--', Contact Person: Special Instructions: Occupancy Type: Phone No.: AApproved per applicable codes. Corrections required prior to approval. COMMENTS: �P Vtetil44., Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:44 (K, c ----(9L------ Date: yn57// Hrs.: 1 100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 14+ - FILE COPY Permit Na • Ike n` x I 3Zo 6116S -ax' � 7�1 - I x(23' qt - 'OW `1` x Lam' = OS16114.1ci Hirrelp a9,64C' 4014 * Z x 1o1 terZA bi' (VD) e 4� 51110 c� Waterloo - 1.04$ 14 v\Qafect *ice 4441 72 �� OsauW, &%. '" 7'4 RECEIVED CITY OF TUKWILA NOV 18.2013 blk-411. 03 5 2. PERMIT CENTER Element: Pet -1M s- 12-. WALL — SKETCH Df ELEMENT Note: hake copies of this form for every bulldinp elemtml. �lgv AYP• w/ VAfbR ' m, '14 -11 I tJ�iu1-. 2X4''jrvil*. r0./G. Framing Ratio (if applicable) s Material Inches Inches Ann Thickness P Value Solid R value Cavity mo(P?-. 4I PL -M , (oI l 1 (UL. •el' 40,f .t>1' WVa r-ub 05 o it 'l8 4.64P. ' • .9_e o 4.-9p *1 Va MR. r([ -M 41 ■ �r . . -Surnmation R V&ues 21 u ` 1/11A 044. '_ U Ve.'ue for Element (&.v9.) kea of Element` " Area of Element Is net wee atter openings such as doors, %indoos and skyrig!hts have been subtected. RECEIVED CITY OF TUKWILA NOV 1.8 2013 PERMIT CENTER 2C12Was:rim:Ton State Energy Code Compliance Forms for Commercial, Group Ri, and > 3 story R2 R3 Envelope Summary ENV -SUM 2S12 :i -,c -Cpm E-elsoy ax :.7 ia-ce Fite 'tar Con -e. -:e. Gas ' CTM:R2&R3 Re:.beo hs* 2013 Project.Info A • rL. Date 11-14. 13 - ,rs For Building Department Use COPY IIILE ;,......4-,.. Ne Glu 4p .5eIALE1 bIZGtirrecr n kern Addres<. MVP re'�I64¢ Rz 9V MltC1.E; h . $i61F" lAppacant Phone: Reis .4V -A.,-.3 =fieri . Project Description ❑ Chance of Occ anc,,i'C.«,-rc=,I_rl 0 New Building • Addition Zg Alteration Compliance Path ■ Prescriptive 174 Component Performance : Tvai 5:r-crc P ra-tx Occupancy Group ' Commercial 0 Group R (R-1 & > 3 story R-2 anc R-_ .. z Climate Zone eir Climate Zone c`'7 9 0 Climate Zone (tb( See ‘VSEC 3::' - 'zr m-rra iS Vertical Fenestration and Skylight Area Calculation If co/pplying via the Prescriptive path, provide values for vertical fenestration, skylights, gross walls end roof. If complying via the Component Performance path, these values are auto- filled by the ENV -UA form and cannot be edited here. Total Vertical Gross Exterior Fenestration Above Grade (rough opening) divided by Wall Area '. _ times 100 -u matt. cr 101 ÷ I LCO X 100 =: 'b Gross Exterior Total Skylight divided by Roof Area times 100 ept a.s ',: Skylvt of c T X 100 = Maximum Prescriptive Fenestration Area Vertical Fenestration Skylights Wit 50% Floor Area in DLZ 0 More than 50% of the floor area in daylight zone per C402.3.1.1 Semi -Heated Path 4 and has a ,r, nev ng system for requiremenm. other conditioned soaces - :or: or Component F -e x rr ::,-r, s. ce spats s •.:.s C' n^ -- • Project has semi -heated areas as defined per C402.1.4 • Applying wall exception to semi -heated areas 1. To be deemed semi -heated the area is heated but not cooled, output capacity between 3.4 - 8 Rtuh/ft2. Refer to C402.1.4 2. Semi -heated spaces shall be documented separately from separate compliance forms for each conditioned area type. 3.Semi-heated spaces may comply under the Prescriptive path. 4.Envelope elements separating semi -heated from other conditioned thermal envelope requirements for an exterior wall. Refrigerated Spaces freezer of Occupancy/Cox-boning only. Compliance dot xr tr the ENV -PRESCRIPTIVE. tern _: -ef • Walk-in cooler ■ Walk-in • Refrigerated Warehouse Cooler ■ Change Refrigerated spaces shall comply under the Prescriptive Path these areas may be combined with non -refrigerated areas in Mixed Occupancy and/or Space Conditioning Project includes more than one occupancy type and/or level compliance forms may be required. Select all that apply to scope of space conditioncig. Afi.,=e of project: 0 Refrigeratec Soac* 0 Low Energy' and compliRE ekeivz D f'` I- - V n i= Ti WWII i 76 Commercial 1 Group R1 or >3 story R2/R3 gFully Conditioned 0 Semi -Heated ■ Group R2/R3 < 3 story *Low energy areas are exempt from all thermal envelope provisions these areas am not required. Refer to C101.5.2 for exemption. to\ -035Z NOV 16.2013 PERMIT CENTER 2012 Washington State Energy Code Compliance Forms for Commercial. Group R1 _ and > 3 story R2 R3 Envelope Summary (back) ENV -SUM 2012 Washington Stave Energy Cafe Crarroiaoe For `ac Cru e- er r = -c > 3 =+sy R2 & .?.•ser .t.ne r' - Minimum Requirements for Prescriptive Option tc .e,m cr ' cuaLfS fo the opticr.,al ?-es." cove CrAtcir• Ary moo Sent rnust meet the s:a:ec rea :,-ire ti. Climate Zoon Climate Looe 4.J5b Climate Zone 6b Occupatuv Group All Other Group R All Other - Group R Opaque Elements Insulation Min. R-Value''r Roofs Insulation Entirei> above Deck R-30 c.i. R-38 c.i. R-38 c.i. _ R-30 c.i. Metal Building iwith R-3.5 thermai block!!` R-25 + R-11 Ls R-25 + R-11 Ls R-25 + R-11 Ls R-25 + R-1 I Ls i Attic and Other R-49 R-49 R-49 R-49 Walls. Above -grade Mass R-9.5 ed.` R433 cic R-11.4 c.i.` , R-15.2 c.i.` Meta! Building - R-13 + R-13 c.i. R-13 + R-13 c.i. R-13 + R-13 c.i. R-19 + R-16 c.i. Steel Framed R-13 + R-10c.i. R-19 + R-8.5 c.i. R-13 + R-12.5 c.i. R-19 + R-14 c.i. Wood Framed and Other R-21 int R-21 int R-13 + R-7.5 c.i., or R-21 + R-3.8 c.i. R-21 + R-5 c.i. Below Grade Wall Same as above grade Same as above grade Floors Mass R-30 c.i. R-30 c.i. R-30 c.i. R-30 c.i. . Steel Joist (per footnote c) R-38 + R-10 c.i. R-38 + R-10 c.i. R-38 + R-10 c.i. R-38.0 + R-10 c.i. Wood Framed and Other R-30 R-30 R-38 R-38.0 + R-10 c.i. 4 Slab -On -Grade Floors Unheated R-10 for 24 in. (with thermal break) R-10 for 24 in. (with thermal break). R-10 for 48 in. (with thermal break) R-15 for 48 in. (with thermal break) Heated R-10 perimeter & under entire slab R-10 perimeter & under entire slab R-10 perimeter & under entire slab R-10 perimeter & under entire slab Opaque Doors Maximum U -Factor Swinging U-0.37 U-0.37 U-0.37 U-0.37 Roll -up or sliding R-4.75 R-4.75 R-4.75 R-4.75 Fenestration 0-30% of Wall Assembly Maximum U -factor (NFRC Rated) Vertical Fenestration Nonmetal framing U-0.30 U-0.30 U-0.30 U-0.30 Metal framing (fixed) U-0.38 U-0.38 U-0.36 U-0.36 Metal framing (operable) U-0.40 U-0.40 U-0.40 U-0.40 Entrance doors U-0.60 U-0.60 U-0.60 U-0.60 Skylights Skylights U-0.50 U-0.50 U-0.50 U-0.50 Fenestration 0-30% of Wall Assembly Maximum SHGC Factor Vertical Fenestration 0.2 S PFa0.5: PF<0.2: all orientations - SHGC-0.40 PF < 0.5: north - SHGC-0.44, all other SHGC-0.48 north - SHGC-0.48, all other - SHGC-0.64 Skylights SHGC-0.35 )SHGC-0.35 SHGC-0.35 !SHGC-0.35 For SI: 1 inch .= 25.4 mm. ci .= Continuous insulation (see footnote f). NR .= No requirement. LS .= Liner system -A continuous membrane installed below the purlins and uninterrupted by framing members. Uncompressed,unfaced insulation rests on top of the membrane between the purlins. a Assembly descriptions can be found in Chapter 2 and Appendix A b Where using R -value compliance method, a thermal spacer block shall be provided, otherwise use the U -factor compliance method in Table C402.1.2. c R-5.7ci is allowed to be substituted with concrete block walls complying with ASTM C90, ungrouted or partially grouted at 32 inches or less on center vertically and 48 inches or less on center horizontally, with ungrouted cores filled with materials having a maximum thermal conductivity of 0.44 Btu-in/h-ft2 EF. d Where heated slabs are below grade, below -grade walls shall comply with the exterior insulation requirements for heated slabs. e Steel floor joist systems shall be insulated to R-38 .+ R-10ci. f For roof, wall or floor assemblies where the proposed assembly has penetrations > 0.04% of the area, the assembly is not 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 R3 Building Permit Plans 2012 Washington State Er .auv Case (IJvnrdio.+... Checklist Date ti ENV -CHK v.— -... `-_ r-- -- • . n o' ~xj > 3 story R2 & R3 ?arse` ht.e 2013 Project Address Oj 1j-4 E. ilk) Q 6106 L VIA? &') I_l 4-.113 The following_information is necessary to check a basking pem:rt app abort for compliance witn the budding envelope reouirements in the Washington Stale Energy Code, Commencai ?rovisbns. Applicability (yes,n0,na) Code Section Component Information Required Location on Plans Building Department Notes SCOPE (Section C101) WA C101.5.2 Lcw energy spaces Low energy (unconditioned) spaces identified on plans 0101.5.21 / 0402.1.4 Semi -created a Paces Semi -heated spaces identified on plans C402.5 / C402.6 Walk-in and refngerated warehouse coolers and Cooler and freezer spaces identified on pians C101.4.6 Mixed occupancy Spaces with different occupancy requirements identified on plans .r - 1 014 0101.4.4 / C101.4.5 Change in Occupancy/space Existing building spaces undergoing change identified on plans ENVELOPE PROVISIONS i C303.1 Insulation identification Identification mark to be applied to all insulation materials 'T1 Lf C303.1.3 0402 4 3/ Fenestration product ratir Fenestration products labeled with rated U -factor, SHGC, VT, leakage rating 1.--1 Lf General installation indicate installation method, densities and clearances to achieve intended R -value of all insulation materials i �' 1 , LI C402.2.1 Roof assembly insulation Indicate R -value on roof sections for attics and other roofs; Indicate clearances for attic Insulation; Indicate baffles if eave vents Installed; Indicate face stapling of faced bans ^1' i `' Lf C402.2.3 Above/below grade wall insulation Indicate R -value and framing material on wall sections; Indicate face stapling of faced bats; Indicate above grade exterior Insulation 1a protected; Indicate mass of masonry walls if mass wall claimed Indicate loose -fill core Insulation for masonry walls as necessary Indicate frequency of grouted cores and bond beams as necessary I:- 5 C40.5 .5 / C402.2.6 Walk -In and refrigerated warehouse coolers and freezer Insulation Indicate R -values for walla, ceilings, doors and floors in sections Lf C402.2.7 doors (4 50% glazin glazing) Indicate rated U -factor (swinging) or R -value (roll-up/sliding) on wall sections 'T -1 -,1 ,, ( 11 /[ ���fff /"( 0402.2.5 Floor over outdoor or unconditioned space insulation Indicate R -value on floor sections; Indicate substantial contact with surface; Indicate that insulation does not block airflow through foundation vents. linsulation C402.2.6 Slab -on -grade floor Indicate R -value on wall section or foundation detail; Indicate slab insulation extends down vertically required distance from top; Indicate above grade exterior insulation is protected �� ) Illks C402.2.6 Radiantly heated stab ort grade floor insulation indicate R -value on wall section or foundation detail; Indicate slab insulation to full slab depth and under entire slab; above grade exterior insulation is protected IIndicate C402.2.8 Thermal radiation system indicate insulation of panels, U-bend/headers & floor structure Is min. R-3.5 1 C402.3.1 Vertical fenestration max Provide calculation of vertical fenestration area as % of gross wall area -r,1 1, jp C402.3.1.2 Skylight maximum area Provide calculation of skylight area as % of gross roof area yChap 2 Def. Daylighting zone Provide calculation of % of overall conditioned floor area in daylight zone '1'- 7.- LC402.3.3 41/ C402.3.3 U -factors and SHGC for vertical fenestration, glazed entrance doors and skylights Indicate U -factors and SHGC values in fenestration schedules; Provide area -weighted calculations as necessary; Indicate if values are NFRC or default, it default then specify frame type, glazing layers, gapwldth, low -e coatings, gas filling 0402.3.3 / C402.3.3.1 Permanent shading devices Provide projection factor calculations for North and Non -North orientations AIR LEAKAGE ti C402.4.1.2.1 Air barrier materials indicate ASTM E2178 rated materials used to provide air barrier on plans T-1.. 1 1 0402.4.1.1 / C402.4.2 Air barrier construction and sealing indicate location of continuous air barrier on plans; Provide details for all joints, transitions in materials, penetrations in air barrier and note method of sealing (caulked, gasketed, or other approved method) '1' , I C402.4.3 / C402.4.4 Fenestration, door and access opening leakage Indicate air leakage rating and/or method of sealing for all fenestration, doors and access openings In schedules ^ i 1 11 C402.4.8 Recessed lighting fixtures indicate IC rating of fixtures in lighting equipment schedule; Indicate method of sealing between housing and wall or ceiling in plans -}l-� - Z- 1.1)4 C402.4.5.1 Stairway and shaft vents Indicate locations of all stairway and shaft vents; Provide leakage rating of motorized dampers In equipment schedules C402.4.5.2 Outdoor air intakes and exhausts Indicate locations of all outside air intakes and exhausts; Provide leakage rating of dampers and identify whether motorized or gravity in equipment schedules C402.4.6 Loading dock seals Indicate weatherseal at cargo and loading dock doors C402.4.7 Vestibules Indicate locations and dimensions of vestibules in plans; For unconditioned vestibles, indicate which wall assembly (interior or exterior) insulated to exterior wall requirements C402.4.1.2.4 Air barrier building test indicate air barrier test method conducted In accordance with ASTM E778; 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1. and > 3 story R2 R3 Component Performance Path ENV -UA 2012 Was r Smre ^rrr��•-¢ =. ��r-s- .d. Grou: =c ar+c > 3 story R2 & R3 ..re 2 • a Project Addressg lj ' E, trt gal Lt5 L W 0 Darts 1144477 Occupancy Group ity '==.,,.--,e.i.:2' :21 Group R (R-1 & > 3 story R -2/R-3) Clear tar Btriorng Cepartmert Use Climate Zone 3 __ 4,„torr Change in occupancy or space conditioning 0 Note - Prapasei UA tray es eed Target UA Dy 7091; per C701.4.4 and C101.4.5 Fenestration Area as % gross exterior AG wan area 1 tj % Max. Target: A % Skylight Area as % gross exterior roof area 14 `/ Max. Target: 50°/o Floor Area in DLZ 0 50`- of th«:':ocr area in iriaviignt zone per C402.3.1.1 Notes: 1: If vertical fenestration or skylight area exceeds maximum allowed per 0402.3.1, then Target Area Adjustment of all applicable envelope elements will be calculated by the compliance form. Refer to sheet on the backside of the ENV-SHGC form for this calculation. 2: U -factors shall cane from Appendix A, chapter C303, or calculated per approved method es specified in C402.1.2. 3: Refer to ENV -CHK worksheet for example of how to complete the rows on this form. Building Component Provide source of U -factor. page/plan # of assembly detail & ID Proposed UA U -factor x Area (A) = UA (U x A` Target UA U -factor x Area (A) = UA (U x A) y $ m 3 R= ID: R= ID: R= ID: I Above Deck Insulation set occ. p T. g R= ID: R= ID: R=ID: I I Metal Building', " • ' • set occ. ' r O R=41 ID: dN (./Z-% IA WCt R= ID: R= ID: '(77, i 684 11s(e8 0,62 ! Eif741- t-biey Single raft, attic, other set occ. p €R= l E ID: R= ID: R= ID: I 1 SteeUmetal frame set occ. Opaque Walls - Abo Mass* lwood/pti Mtl Bid. R= ID: R= ID: R= ID: Metal Building set occ. R= 6 ID: Nee ,-/-K(0 R=t1 ID: VA -DO S' 1 P ,,U( Ca R= ID: 17.CLI e", t3 ; I. of!, (VI i:V I'42l 4 4 0, O4i i 10 t *34,4' Wood Frame, other set ox. R= ID: R= ID: R= ID: ! ! j Mass Wall set occ. g mTo -v To •o ,. R= ID: R= ID: j I I 1 Assumed to be Mass Wall set occ. R= ID: R- ID: g V, is 2 R= ID: R= ID: R= ID: Mass Floor set occ. $ g ti R= ID: R= ID: R= ID: Joist/Framing set occ. F -factor : x Perimeter := UA(U x A) F -factor x Perimeter = UA (U x A) 1 Slab -on -grade sR= R= ID: bit Q rf ID: R= e? ID: Iutletioe, aviv1t1612, °'9A 1f.:. gym'/i 12. ii,47_, Z,.5(p ois-4- ti 011,.•)e Slab -On -Grade set occ. '$ an = R= ID: R= ID: R= ID: _ Heated Slab -On -Grade set occ. ?Se e e'het>y ♦�PpefIcriixx A values: Parts must ereTr slate Pa alue g foo hoer s. Pagel Subtotal Area I UA 1030 I15.tel UA Ileo 107, b3 20 2. Was:anion State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 R3 Envelope UA. continued. ENV -UA Proec'.gest. ._`Vi e ilOeCilCI6L W'l l v" l(D% Date 61,�L�,1,3 Fenestration Area as % exre^�or wall area Max. Target: °j5 For Building Department Use Skylight Area as % assex ,,x roof area D Max. Target: N Notes: 1 if /sxal' 4ar,es.-zror cr sk-Aolht siva exceeds maximum allowed per C402.3.1, then Target Asa .:47 w of of awe enveiope elements will be calculated by the compliance form. .M weer r e.`le o ' ' ' of die =NV-SHGC form for this calculation. 2: =rosaaie :F.: o' Adorn= A U -lector for fenestration assemby (combined frame and glazing oe^a-anoey 3: Refer to ENV-CrIK worksheet for example of how to complete the rows on this form. Building Component U-tactor�V, ppclage/plan # of assembly detail & ID Prorr_e�so•S of,D: Proposed UA U -factor x Area (A) = UA (_U x AN Target UA , U -factor x Area (A) = UA (U x A) �, .3 $ arm = oi U= ID: U- ID: dr Sb ' 42— 21 me ) 4L 2y,j. Opaque Swing Doors set occ. a c $o o: U= ID: U= ID: U= ID: Opaque rollup & sliding set occ. Vertical Fenestration I To o c Z U= ID: U= ID: U= ID: i i Non -Metal Frame set occ. Metal, fixed ().% ID: 13ai11tiOtA161 lAttlitakA U= ID: U= ID: U= ID: b, 3f5, i i -is i bc, i c.f,3i . /Di- '?b.'(e Metal Frame, Fixed set occ. 6. ° c0 1 U= ID: U= ID: U= ID: U= ID: Metal Frame, Operable set occ. ' g B o k- U= ID: U= ID: U= ID: U= ID: , Metal Entance Door set occ. 4 Q, ,s' cn u, a ~ ¢ U= ID: U= ID: U= ID: U= ID: I All types set occ. Page 2 Subtotal Page 1 Subtotal To comply: 1) Proposed Total UA shall not exceed Target Total UA. 2) Proposed Total Area shall equal Target Total Area. Total Area UA /Act ci//el�, (p (P icaCom.) il-/a e1 1a2c 2«,21 Area UA F7o 1( 10Z,t� I a2q ZW(a,4ti, 2012 Washington State Energy Code Compliance Forms for Commercial, Group RI, and > 3 story R2 R3 SHGC Calculation ENV-SHGC 2012 Was`1irSton State Energy Code Compliance Forme ^roup R1, and > 3 story R2 & R3 Re.uea June 2013 Project Aorress / e- 1" U Uyillb t. G;C) Date u.4. j 3 o Fenestration Area as % gross extenr wat area (Q Prop 'N Max.Target or : uitding partment Use Skylight Area as 4 gross exterior roof area 1414.- Prop Max.Target To comply ire Proposed rota/ SHGC x44 for ail fenestration (vertical & skylights) s'lae rot exceed Target total SHGC x A. Skylights Proposed SHGC Provide SHGC source (NFRC or default), page/plan # of detail & ID SHGC x Area (A) = SHGC x d Target SHGC SHGC x Area (A) = SHGC x A ID: ID: VP\ ID: ID: ID: , SHGC set ox. a Note: Compliance is based upon combined skylight and Totals vertical fenestration performance. Totals) All Non -North Vertical Fenestration+ Proposed SHGC Provide SHGC source (NFRC or default), page/plan # PF SHGC* x Area (A) = SHGC x A of detail and ID ID: ID: ID: ID: ID: ID: ID: ID: ID: ID: u/k., o1 0 0 0 0 0 o i 0 0 Target SHGC ++ PF SHGC x Area (A) = SHGC x A Category PF < 0.2 I 0.40 0.2sPF<0. 0.48 PF t 0.5 I 0.64 ++ If projection factor (PF) credits we applied to the proposed design, Target SHGC will sum fenestration area by PF category. + If projection factor credit is applied, then vertical fenestration must be entered in the correct table according to orientation. If credit is not applied then all vertical fenestration can be entered in either table. * Note: Fenestration that separates conditioned space from a non -conditioned or semi -conditioned space shall be listed here with a proposed SHGC equal to the target value. Totals Totals North Vertical Fenestration+ Proposed SHi Provide SHGC source (NFRC or default), page/plan # PF++ SHGC' x Area (A) = SHGC x A of detail and ID Target SHGC++ PF SHGC x Area (A) = SHGC x A Category ID: WO Au.iell)4Uti*rOet i041— ID: , 0.40 • i ID: 0 • 1 ID: 0 ID: 0 ID: I 0 0 C3 .40 PF < 0.2 1 0.40 t#01 g 0.25PF<0.5; 0.44 PF 0.5 1 • 0.48 ++ If projection factor (PF) credits are applied to the proposed design, Target SHGC will sum fenestration area by PF category. North Total To comply proposed total SHGC x A shall not exceed Target total SHGC x A. 20T 8z, g Grand Total n, Area SHGC x A 62<8 Area SHGC x A Grand 44 Total 1 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Interior Lighting Summary LGT-SUM 2012 Washington State Energy Code Compliance Porus kir Cc Convreel.. Grout R t arc > r R2 a -ad R3 Reese() June 2013 Project Info PrgectAddress 6 2 - • Date 1I÷el- 13 ----...„ ". r ) eCI ILVA \*A -i 00< For Building Deparrnent Use FILE COPY Applicant Name: iet itzr �fi�, �RObiQ. D2 ! - gyp. Applicant Address: Applicant Phone://o,� _Y-3 _EAg . Q4 �(' s"' Project Description ❑ New Building 0 Addition % Alteration ■ Plans Induded Lighting Compliance Path 4 Lighting Power Density Calculations 0 Total Building Performance (If Total Building Performance then only LGT-CHK is required.) Interior Lighting Compliance Option Q Building Area Method () Space -by -space Method Interior Lighting System Description Briefly describe lighting system type and features. , X4 E %rb , 116E V611-17 Additions and Change of Space Use (0101.4.3 & C101.4.4) Rf Addition area or Change of Space Use area complies with all applicable provisions as stand alone project ❑ Addition area or Change of Space Use area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use scope. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) • 60% or more of luminaires in space replaced Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document mall/num and proposed (including existing) lighting wattage of project scope Provide allowed 60% of luminaires in space replaced Space -by -space Method (LTG -INT -SPACE) Compliance Form. Document existing total wattage in space and proposed existing) lighting wattage of project scope • Less than Provide (including ballast replacement within existing luminaires only - existing total interior building wattage not increased • Lamp and/or XNew wiring Provide application installed to serve added fixtures and/or fixtures relocated to new circuit applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific controls (C405.2.3), and commissioning of lighting controls per C405.13 lighting panel all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of per C405.13. • New or moved Provide lighting controls reconfigured - luminaires unchanged or moved only all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per 0405.13. • Space is Provide are being made to the interior lighting and space use not changed. • No changes b13-0352 RECEIVED CITY OF TUKWILA NOV 18: 2013 PERMIT CENTER 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Interior Lighting Summary - Space -by -Space LTG -INT -SPACE 2012 Washington State Energy Code Compliance Forms rrw rrnwir. , i ' ---- --d > 3 story R2 and R3 Revised June 2013 Project Info Project Address qfj - . .. Date ' Jil. ' 1?� c i e, mbeell o�w o) For Building Department Use Watts Proposed Applicant Name: 2/ 1 0( Lt 2 x ri � . Maximum Allowed Lighting Wattage Location (plan #, room #, or ALL) Space Type* Allowed Watts per ft2 Gross Interior Area in ft2 watts Allowed (watts/ft2 x area) '11- i 4I- G- tce 0,611 bs4 82* fii X3)4 avip ar fuioefedelst 4 2 jt, Atrium** Enter Height: Retail Display Allowance from LGT-INT-DISPLAY Select Table C405.5.2(2) category from drop down menu. " For atriums, indicate height.Allowed wattage for first 40 feet is 0.03 W/ft. ht., above 40 feet is 0.02 W/R ht. Proposed Lighting Wattage Total Area Allowed Watts bbeir Location (plan #, room #, or ALL) Fixture Description (include exempt equipment r Note 3) Number of Fixtures Watts/ Fixture Watts Proposed .. i/ 2 WA- 6 illa& u> c i' b Eb 14 fii X3)4 avip ar fuioefedelst 4 2 jt, Retail Display Lighting from LGT-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts E.704 - Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 0405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For lighting equipment eligible for exemption per 0405.5.1, note exception number and leave Watts/Fixture blank. 2012 Washington State Energy Code Compliance Forms for Commercial. Group R1 and > 3 stun, R2 a =u R3 Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 12 Was`.:ngton State Energy Code Compliance forms for Cornmero:a: G o .Y R1 and > s:--. o� c Drc,e =cress �i � Irtoec,tl ,u j' 00 j.:a:e 1I141 The following information is necessary to check a permit application for compliance with the fighting motor. and transfcrrrer recu+re^rents in the 2012 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Departme- Notes LIGHTING CONTROLS (Section C405 2) l.{0405 21 Manual lighting controls Lighting control schedule with type, locations served, 50% lighting reduction method - µ%jt 0405.22.1 Automatic time switch controls Lighting systems automatic shut-off capability - indicate method and location served on plans. Note locations where automatic shutoff is provided by other method (occupancy sensor, daylight controls, etc)_ Override switching Schedule with locations served - no single override switch exceeds an area of 5,000 SF C405.2.2.2 Occupancy sensors Schedule of locations served C405.2.2.3 Daylight zones `I Vertical fenestration Primary and secondary daylight zone areas indicated on plans 11 L Skylights Skylight daylight zone areas indicated on plans ‘1 I ,405.2.2.3.9 Daylight zone controls Lighting control schedule with dimming method and locations served - no single daylight control zone exceeds 2,500 SF .� 6' 2- I /4/Ac �,y 04052.3 Specific application controls Specific application lighting controls are independent of general area lighting and controls for other lighting applications _lighting Means of egress Lighting control schedule with method and locations served. Note luminaires that function as both normal and egress. Display lighting Lighting control schedule with type and locations served Accent lighting Lighting control schedule with type and locations served HoteUmotel guest rooms Lighting control schedule with g type and locations served Supplemental task lighting Lighting control schedule with g g type and locations served Non-exempt lighting equipment Lighting control schedule with type, applications served and locations Non-exempt lighting equipment Lighting control schedule with type, applications served and locations y 0405.2.4 Exterior lighting controls Lighting control schedule with type, features and location served INTERIOR LIGHTING POWER (Section C405.5) 0405.5.1 Total connected lighting power Schedule with fixture types, tamps, ballasts, watts per fixture 172_ 144 Space exceptions Space exceptions taken noted on plans or compliance form Lighting equipment exceptions Equipment exceptions taken noted on plans or compliance form 0405.5.2 Lighting power calculations Building Area Method Compliance form completed - proposed wattage per building area does not exceed maximum allowed wattage 1 Space-By-Space Method Compliance form completed - total proposed wattage does not exceed maximum allowed wattage ...ro� c, 1/%6 C405.4 Exit signs All internally illuminated exits sign are < 5 watts per side EXTERIOR LIGHTING POWER (Section C405.6) I F-1/�j 0405.6.2 Total connected lighting power Schedule with fixturetypes,lams ballasts, watts lamps, per fixture Exterior application exceptions Exterior application exceptions taken noted on plans or compliance form Lighting power calculations Compliance form completed - proposed wattage for exterior lighting plus base site allowed does not exceed max. allowed 0405.6.1 Exterior building grounds lighting Schedule with fixture types, lamps, ballasts, watts per fixture; lumens per watt for fixtures > 100 watts ELECTRICAL POWER SYSTEMS (Sections C405.7 ,C405.9, C405.12, C409.2.1) • PLAN R r MORI, W/ROUTING SLIP ACTIVITY NUMBER: D13-0352 DATE: 11-18-13 PROJECT NAME: SPEC 2 SITE ADDRESS: 9124 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPA TMEN S. uiing Di isi n _rte V ublic s Fire Prevention Structural 0ii-13 \b\ MP tt. i. P anning Division ❑ Permit Coordinator 111 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 1 1 -19-13 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please RouteNI/ Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: DUE DATE: 12-17-13 Approved with Conditions N- Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 TCL PARTNERS CORPORATION 0 Washington State Department of Labor & Industries • Page 1 of 2 TCL PARTNERS CORPORATION Owner or tradesperson SYLESTER, FRANCES MARIAN Principals SYLESTER, FRANCES MARIAN CARL MERISKO BRIAN MERISKO DAVID MERISKO SUSAN SYLVESTER SCOTT SYLVESTER JAMES SYLVESTOR Doing business as TCL PARTNERS CORPORATION WA UBI No. 602 930 767 16000 MILL CREEK BLVD MILL CREEK, WA98012 425-316-3500 SNOHOMISH, County Business type Corporation Governing persons BRIANJAMESMERISKO License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. TCLPAPC919QD Effective — expiration 11/04/2009 — 07/10/2015 Bond American Contractors Indem CO Bond account no. 100087506 Received by L&I 07/10/2009 Active. Meets current requirements. $12,000.00 Effective date 11/04/2009 httns://secure.lni.wa.gov/verify/Detail.aspx?UBI=602930767&LIC=TCLPAPC919QD&SAW= 01/07/2014 BUILDINCs ANP, SITE T4TISTICS BUILDING CODE: ZONING: SITE AREA: EX: BUILOINp A� EA: SPCC TENANT ShACE: OAFICE (6} UTAREEIOUBE lSlk IBC 2012 MIC/I4 160,396 SF 29,812 SF FIRST FLOOR 1,416 SF 884 SF FIRS' FLOOR 6,592 SF FIRST FLOOR TYPE OF CONSTRUCTION: v5 PARKING EX. 514O4UN: $9 STALLS NQ CHANGES, 4 HC PARKING II EP: OFFICE "•" 1/250 = 3.5 CARS UJAAE a IPPOO : 3.3 CARS TOTAL REHIRED 1 CARS PROJECT C.QST ESTIMATE: a, 25,400 OUJVERSHIP: LOS ARBOLES P.0.15QX 654 KIi KLAND, WA 98083 TAX ID NUMEER: 542260015004 LEGAL. DESGRIPTIQN: THAT PORTION OF THE FRANCES MCNATT DONATION LAND CLAIM IN SECTION 33, TOWNSHIP 24 NORTH, (RANGE 4 EAST,11.1.M., DESCRIBED AS FOLLOUJS, BEGINNING ON THE EASTERLY MARGIN OF EAST MARGINAL UJAY AT A POINT SOUTH 23D40'59" EAST 895.56 FEET FROM THE INTERSECTION OF SAID EAaTERLY MARGIN AND THE NORTH LINE OF SAID DONATION LAND CLAIM, THENCE NORTHWESTERLY ALONG THE EASTERLY LINE 01 EAST MARGINAL U)AY 352.65 'FEET TO 114E SOUTH LINE OF BOEING FIELD, THENCE NORTH 89D58'1T" EAST ALONG SAID SOUTH LINE OF BOEING FIELD 414.62 FEET TO. A POINT ON A LINE WHICH IS PARALLEL WITH AND 500 PEEP WESTERLY MEASURED AT RIGHT ANGLES TO THE CENTER LINE OF BOEING FIELD MAIN RUNWAY NO 4, THENCE SOUTH 291)52'38" EAST ALONG SAID PARALLEL LINE 312.42 FEET, THENCE SOUTH 89D58'11" WEST TO THE POINT OF BEGINNING± (BEING KNOWN AS A PORTION OF TRACT 6 OF THE MEADOWS, ACCORDING TO THE UNRECORDED PLAT THEREOF), SITUATE IN TI -IE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON, SCOPE CF WORK: CONSTRUCT NEW 8$4 SF OFFICE WITHIN AN EXISTING WAREHOUSE SPACE, REMOVE F'ORTICN OF WALL, ADD SUPSENDED CEILING AND NSULATION, PER PLAN FLANN!NQ APPR7�� E changes "can be made to these plans without approval from the Planning Division of DDI roved By: ML1► REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan subrailai and may include additional plan review fees c\ 7 SEPARATE PERMIT REQUIRED FOR &fi Iuumbhtp wells Piping City of Tukwila BUILDING DIVISION SITE PLA\ NORTH SCALE: 1" ; 40' F COPY Per mit ft. Plat view euibmtbaeonsedoetedons. toroval of con*uclon dews* 11at ateniZO lig :otatIon of+e w adopted code or ordinance. Receipt iavedl etc fop l' ic11ar101Me1kpd: OMK..mel-l-2oyi City OtWeft WILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED DEC 10 2013 City of Tukwila BUILDING DIVISION b3O3&Z RECEIVED CITY OF TUKWILA NOV 1 8 2013 PERMIT CENTER C:1Documents and Settingsvkil Users\Documents\CAD120111i 118 AIRFIELD BUSINESS (9931)\91241T-Q.dwg, T 5.0 8.0 - FLOOR FLAN ; DEMO NORTH cALE: 1/8', = 1i -0n DEMO NOTES: 1. FATC-4 ANP REPAIR FLOOR, .UAL..1-S AND CEILING AS REQUIRED 2. ANY POWER IN WALL, REMOVE TO 4 )-Ox AT ROOF STRUCTURE AND LA5EL WITH PANEL °AND CIRCUIT° DOOR $1-4Er)ULE:19ROVIIpt LEVER HANDLES TI4ROUGHOUT El EX. 3 'X'1' ALUMINUM STOREFRONT WITH EXIT PADDLE (REPLACE WITH NEW INSULATED U=0.18) E2 EX. 3'Xi' $C WOOD, wooJAM5, LATCHSET E3 EX. 3'X1' H. MTL. DOOR AND JAMES, LOCKSET, INSIDE HANDLE TURNS FREE FOR EXIT NI New 31-01X11,0" SC WOOD DOOR, WOOD JAM, 1 1/2 PAIR aUTTS. LOCKSET, WALL. STOP, SILENCERS N2N1 NEW 31-01k1c0" SC WOOD POOR, WOOD JOS, 1 1,2 PAIR !WITS, PRIVACY LOCK, WALL STOP, SILENCERS (ADD UJEAHTERSTRIP TO N3XU=0.50) N4 NEW 31-06)(11-0" $C WOOD POOR WQOP JAMS, 1 1/2 PAIR MITTS, LOCKSET, WALL STOF, CLOSER, THRESHOLD,WEATHERSTRIP (U40.$0) ROOM 1,2 FLOOR: 13ASE: WALLS: CLG: 3,4 FLOOR: 'BASE: WALLS: CLG: 5 FLOOR: ASE WALLS: CLG: NEW CARPET NEW ftJEER !BASE NEW G'11=' Bp PAINT (EE) NEW SUSPENDED Acoustic +S'AFF NEW SHEET VINYL NEW SHEET VINYL COVE0 (6") NEW 4' PLASTIC LAMINATE WAINSCOT (ALL WALLS) GYP 15D. PAINTED ABOVE (GE) GYP OD PAINTED (s0E) IRE SEA. CONCRETE FLOOR NONE GYP 150 AND CONCRETE, PAINTED (P) expos#p STRUCTURE UJ4LL SCHEDULE A. NEW 3 518" X 25 GA. STEEL STUDS AT 24" O.C. TC) CEILING Aeove, WITH SOUND INSULATION, 5/8" GYP ED. EACH sloe (ALTEATE 2X4 WOOD STUDS AT 24" OZ.) I**IEUJ 2X6 WOOD STUDS AT 24" OC. TO +10' AFF, WITH 1R4.21 INSULATION AND VAPOR SARRIER ON WARM SIDE (U=0041) C NEW 8" TRACK WIT -4 3 5/8" X 200A STEEL snips STAGGER WITH FULL THICK SOUND SATTS, 5/8" WATER PROOF GYP 6D EACH SIDE (ALTERNATE WOOD STUDS) D NEW 3 5/8" X 20 GA STEEL STUD AT 24" O.C. TO GYP ESD CEILING MOVE, WITH SOUND INSULATION, 5/8" 4" WATER PROOF GYP 15D ON RI SIDE, 5/8" GF E312 ON OFFICE SIDE/ALTERNATE 2X4 wool, snot AT 24% OL) cS) (A) WINDOW eCHEIDLILE A. NEW 4' WIDE X 3" TALL AT + 3'-6" AFF SILL, wool" PRAfrte, CLEAR 1/4" POLISHED PLATED GLASS IN WOOD STOPS. S. NEW EXTERIOR ST*--- FRONT SYSTEM, ALUMINUM THERMALLY OKEN FRAME, INSULATED GLAZING (SAFETY GLAZING TQ MEET CODE), (U=0.38, GHc 0A0) SEE ELVATk2N T-2 FULL WIDI4T MIRROR TO DACKSPLASI,I 'I' ‘----6C4g 40" PAINT --i ,i, • Z9 .it 25O' —O' 2'--,5" 23'-5" 23'-5" 22'-8" // / 24' " 23' " •._,_, , / ,_____ a I 1 zo f (PO x. BLDG. SPRINK. EX. UNIT HEATER, RISER REMOVE RELOCATE TO WAREHOUSE 5..,---------, t ' / Sep°. v.& .e..... (vie crietteticot WAREHOUSE OPEN TO \ x # GAS UNIT HEAT (SUSP. FROM CEIL.) STRUCTURE ABOVE / REMOVE EX. SLIDING REMOVE EXISTING POOR FULL HEIGHT WALL EX. GAS UNIT HEAT (SUSP. FROM CEIL) \ WAREHQUSE cALJ | l ' | | SUB. PANEL ' OPEN TO ' STRUCTURE ABOVE ) ; :? ' )).1.•■••€=•••■••• 22'-8" / 1:— " T / 2' ' - FLOOR FLAN ; DEMO NORTH cALE: 1/8', = 1i -0n DEMO NOTES: 1. FATC-4 ANP REPAIR FLOOR, .UAL..1-S AND CEILING AS REQUIRED 2. ANY POWER IN WALL, REMOVE TO 4 )-Ox AT ROOF STRUCTURE AND LA5EL WITH PANEL °AND CIRCUIT° DOOR $1-4Er)ULE:19ROVIIpt LEVER HANDLES TI4ROUGHOUT El EX. 3 'X'1' ALUMINUM STOREFRONT WITH EXIT PADDLE (REPLACE WITH NEW INSULATED U=0.18) E2 EX. 3'Xi' $C WOOD, wooJAM5, LATCHSET E3 EX. 3'X1' H. MTL. DOOR AND JAMES, LOCKSET, INSIDE HANDLE TURNS FREE FOR EXIT NI New 31-01X11,0" SC WOOD DOOR, WOOD JAM, 1 1/2 PAIR aUTTS. LOCKSET, WALL. STOP, SILENCERS N2N1 NEW 31-01k1c0" SC WOOD POOR, WOOD JOS, 1 1,2 PAIR !WITS, PRIVACY LOCK, WALL STOP, SILENCERS (ADD UJEAHTERSTRIP TO N3XU=0.50) N4 NEW 31-06)(11-0" $C WOOD POOR WQOP JAMS, 1 1/2 PAIR MITTS, LOCKSET, WALL STOF, CLOSER, THRESHOLD,WEATHERSTRIP (U40.$0) ROOM 1,2 FLOOR: 13ASE: WALLS: CLG: 3,4 FLOOR: 'BASE: WALLS: CLG: 5 FLOOR: ASE WALLS: CLG: NEW CARPET NEW ftJEER !BASE NEW G'11=' Bp PAINT (EE) NEW SUSPENDED Acoustic +S'AFF NEW SHEET VINYL NEW SHEET VINYL COVE0 (6") NEW 4' PLASTIC LAMINATE WAINSCOT (ALL WALLS) GYP 15D. PAINTED ABOVE (GE) GYP OD PAINTED (s0E) IRE SEA. CONCRETE FLOOR NONE GYP 150 AND CONCRETE, PAINTED (P) expos#p STRUCTURE UJ4LL SCHEDULE A. NEW 3 518" X 25 GA. STEEL STUDS AT 24" O.C. TC) CEILING Aeove, WITH SOUND INSULATION, 5/8" GYP ED. EACH sloe (ALTEATE 2X4 WOOD STUDS AT 24" OZ.) I**IEUJ 2X6 WOOD STUDS AT 24" OC. TO +10' AFF, WITH 1R4.21 INSULATION AND VAPOR SARRIER ON WARM SIDE (U=0041) C NEW 8" TRACK WIT -4 3 5/8" X 200A STEEL snips STAGGER WITH FULL THICK SOUND SATTS, 5/8" WATER PROOF GYP 6D EACH SIDE (ALTERNATE WOOD STUDS) D NEW 3 5/8" X 20 GA STEEL STUD AT 24" O.C. TO GYP ESD CEILING MOVE, WITH SOUND INSULATION, 5/8" 4" WATER PROOF GYP 15D ON RI SIDE, 5/8" GF E312 ON OFFICE SIDE/ALTERNATE 2X4 wool, snot AT 24% OL) cS) (A) WINDOW eCHEIDLILE A. NEW 4' WIDE X 3" TALL AT + 3'-6" AFF SILL, wool" PRAfrte, CLEAR 1/4" POLISHED PLATED GLASS IN WOOD STOPS. S. NEW EXTERIOR ST*--- FRONT SYSTEM, ALUMINUM THERMALLY OKEN FRAME, INSULATED GLAZING (SAFETY GLAZING TQ MEET CODE), (U=0.38, GHc 0A0) SEE ELVATk2N T-2 FULL WIDI4T MIRROR TO DACKSPLASI,I 'I' ‘----6C4g 40" PAINT --i ,i, • Z9 .it VERTICAL GRA 54" --_,A, TOILET PAPER (WIC LAMINATE WAINSCOAT zo f SAR COVED SHEET VINYL BASE INTERIOR ELEVATION SCALE:1/2" = 11-0" z ‘—SGE AINT- 4RAE BAR 16" 24" 1 I I PLASTIC LAMINATE WAINSCOAT-7 ON OPEN SIDE INSOLATEP I10T COLD WASTE PIPE COVER SHEET VINYL SASE INTERIOR ELEVATION SCALE:I/2" = II -0" • 303' 250'-0" / 23'-5" 23'-5" 23'-5" 22'-8" 2L 23'-5" NEW OFFICE 554 SF 0 mop = OCCUPANTS, SINGLE ET 10'-3" CEP. OFFIC 13901/100=1.4 OCC =PI OPEN OFFICE 56601/100=51 OCC ROUGH IN FOR FUTURE COFFEE 5,4R 23,-3I II T2 FUTURE OFFICE EXPANSION 1 OFFICE IRR •3 81-0" 0 /\ EX. GAS UNIT HEAT \4(SUSP, FROM CEIL.) 5 o°o BLDG. SPRINK: RISER PROVIDE SIGNAGE ON ALL SIDES" NO STORAGE ,450YE" WAREHOUSE 131 1-10USE RIR WAREHOUSE 5 /OPEN TO \ STRUCTURE \ ABOVE ) 4 / OPEN TO \ STRUCTURE \ ABOVE 0 WAREHOUSE 6,633 SF 0 1/500 4. 13 OCC. SINGLE EXIT UJAIREHOUSE IS SEMI HEATED NO CHANGES CD I-0 z cn < 22'-8" 24'-2" 22' 303'-8" RESTROOM NOTES: 1, ALL ACCESSORIES TO 5E MOUNTED AT +40" TO OPERATING PORTION 2. INSULATE THE 140T, WASTE AND COED WATER UNDER SINKS 3. TOILET FLUSH VALVE ON THE WIDE SIDE OF ROOM 4. SHEET VINYL FLOORING WITH SEAM SEALER AND COVED 6" SHEET VINYL 5,48E, FLOOR PLAN : NEW NORTH SCALE: 1/8" = P-0" TOTAL OCCUPANT LOAD =22 OCC. REVIEWED FOR ODE COMPLIANCE APPROVED DEC 10 2013 City ofTukwila BUILDING DIVISION • RECEIVED CITY OF TUKWILA NOV 1 8 2013 PERMIT CENTER =oddments and Settings\All users\Documents\CA11201111118 AIRFIELD BUSINESS (9931)\91241T-1-.dWg, T- 01 2: FLAT 2X4 5RACE 8'- 0" O.C. TO ADJACENT WALL PLACE AT IAPPROX. 45 DEGREES TO WALL ATTACH TO TOP' OF 50TH WALLS 101-0" 5ATT INSULATION - TYP. OFFICE WALL FRAMING LU/ATT INSULATION (SEE PLANO 2X60 L)0012 STUDS AT 24" 6.C. VAPOR i5ARRIER AND INSULATION (SEE SCHEDULE GYP. 150. EACH SIDE INTERIOR L1JALL ID4ETAIL/51RACNG ) SCALE:1-1/2" 1'-0" FOR WALLS 41TREATE THAN 8'- 0" IN WIDTH WITHOUT AN INTERSECTING WALL, PROVIDE 120a. WIRES SPLAYED e 45 70 AN EYE SCREW eROOF AND TOP OF 1.1.1A1. ATTACH TOP RuNNER CRACK to CEILING GRID UJrN 2 - *6 x 1 I/8" LONG. SCREWS AT 1-0" TYPICAL STUDS WALL PER SCHD. (FOR WALL INSULATION SEE PLAN) 5/S" GYP. 13D, EA‘ SIDE (FLUSI4 FINISH). REFLtcrtiD4juk cEiLisoPLAI•1 TYP. WALL. 110 REPLECTED CEILING SCALE:1-112" 11-0" TYPICAL WALL FRAMING ATTACH, 'BOTTOM TRACK TO CONC. FLOOR W/ POWDER DRIVEN ANCNPIRS, oR APPROVED 1" EMBEDMENT AT 24" O.C. • 5/8" GYP. ACOUSTICAL BLANKET SOUND WALL. CONC. SLAB ON GRADE .LUALL TO 51,45 . scALE: I-1/2" 11-011 • SECTION SECTION cAULK 6T1. 51:). To FLOOR ALL SOUND AN INSUL. 1.0ALt..8 SECTION PAINT E3LAC 3/4" x 2' FILLER 5L GASKETS 1/4" EACH SIDE OF FILLER WALL TO MULLION SCALE: I-1/2° SILL BELOW DEEP LEG 1R4CK ATTACH 6 SILL AND CEILING - DO NOT ATTACH GYP, BD. TO TRACK STEEL STUD - ATTACH GYp. 81). 2x WOOD STUD WALL 2x LUOOD ELOCKINIG 2 1/2" woot? CASING • I 1/2" x WOOD JAM19 •5/6" x WOOD STOP - SOLID CORE 11.100D DOOR STAINED 5/0" oYF15D. EACH SIDE WOOD FRAME DETAIL SCALEI-1a" 5TOFE:F1PNT NOTE$: I. FRAMES TO IE THERMALLY OKEN ALUMINUM (MATHC EX. COLOR) 2. GLAZING IS INSULATED (SAFETY GLAZING PER COPE -SG) U 0.3E4 3. MATCH EXISTING MULLION LAYOUT 4. SGHC 0.40 5G C•1 SG 5G SG SG NT L,Py4ariec2.N Al V- / 11 11 'TO (SEE SCHEDULE) - STAINED STAINED STAINED /LtNi-L I IT CONTROL: PER SECTION 15133 EXCEPTION 4.b ROOMS SMALLER THAN 300 SF ARE EXEMPT FROM THE DAYLIGHTING CONTROL WITH OCCUPANCY SENSORS CONTROLS. IN DAYLIGI-ITED ZONES, PROVIDE INDIVIDUAL LIGHTING CONTROLS WITH DUAL LEVEL SWITCHING OR AUTOMATIC DAYLIGHT SENSING CONTROLS. SWITCHES 14LL 1-14vE MAX. e0% OF A 20 AMP 'CIRCUIT. SECTION SECTION LIGHTING PRIMARY DAYLII-IT ZONE EQUALS THE HEAP HEIGHT QF THE EXTERIOR VERTICAL GLAZING (91), WITH SECONDARY DAYLIGHT ZONE EQUAL TO 2X THE HEIGHT OF VERTICAL GLAZING (ie') WEATHER PROOFING: 1. CAULK AN SEAL ALL TRANSTIONS FROM DISSIMILAR METALS, CAULK ALL WINDOW FRAMES 156TH INSIDE AND OUT. 2. SEAL ALL OUTLETS• N OUTSIDE FRAME WALLS 3. EXISTING ROOF HAS R-21.3 RIGID ON TOP OF PLYWOOD, ( U 0.041) NO CHANGES EXISTING AREA IS aa4 $F X 0.91 = 805 WATTS ALLOWED 23'-5" • 22'-8" UJALL MID CA WITH !BATTERY IBACK UP 250'-0" 23' 24'-2" TYPICAL WALL 'BRACE SEE PTL 1/T2 NEW SUSPENDED ACOUSTICAL CEILING (SECOND LOOK TILES) SUPPORTED FROM ROOF puiRLINS OR GLIB (NOT STIFFENERS) AT +914Fff. INSTALL R-49 5ATT INSULATION ON TILES IC RATED 2'X4' RECESSED FLUORESCENT FIXTURES AT ea WATTS EACH INSTALL & 2X4 3 TUE FLOURSECNT FIXTURES WITH IC RATING At se WATTS PER FIXTURE = 104 WATTS. INSTALL 4 IC RATED COMPACT RECESSED FLOURESCENT F1XTERS AT 25 WATTS EACH = 100 WATTS TOTAL INSTALLED WATTAGE IS 804 WATTS NOTES: MAX. WATTAGE PER SWITCH IS a0% OF 2Q AMP CIRCUIT 2. PROVIDE OCCUPANC'r SENSORS IN OFFICE 3. PROvIDE DUAL LEVEL SWITCHING IN oFFN OFFICE 4. SWITCH IN PIR CONTROLS EXi-IAUST FAN AS WELL 5. CAULK ALL DOORS TO WAREHOUSE, WEATHERSTRIP AND. PROVIDE THRESHOLDS SPACERr AR, OR OTHrER eur SySTEM, 0 KEEP PERIMETER COMPONENTS PROM SPREADING • APART. 'MIN. AT UN -ATTACHED WALLS M. 2 WALL ANGLE NpTE: ATTACH CEILING AND GRIP TO WALL ANGLE (MouLIDINp) AT TWO ADJACENT WALLS VIA POP RIvETS. 4 *12 GA. WIRES WITHIN 2" OF CROSS TEE CONNECTION ARRANGED AT SO° FROM EACH OTHER AND AT AN ANGLE NOT EXCEEDING 45°. LOCATE RESTRAINT PANELS ,4T 12' QC. IN EACH DIRECTION AND WITHIN 6' OF EACH WALL. 1) 2) NOTE MAIN E3EAMS TEES AND CROSS TEES MAT BE HEAVY 'UT y W/ CONNECTION STRENGTHS 0100 POUNDS IN COMPRESSION 4 TENSION. CEILING AREAS GREATER THAN 1000 SF MUST HAVE LATERAL, FARCE I5RACING VIA DIAGONAL. SFPLAt WIRES, LIMITING MOVEMENT TQ LESS THAN 1/4" AT POINT OF ATTACI-IMENT. NOTE: SUSPENSION WIRES to PE 12 GAGE AT 4' O.C. W/ ATTACHMENT DEVICES CAPAI5LE OF MITATIPKRIVTA,RES MUST i5E PLUME WITHN 1 N e UNLESS COUNTEk SLOPING WIGS ARE PROVIDED ) LIGHT FIXTURES TO BE POSITIVELY ;ATTACHED TO MAIN AND CROSS TEES. AND IF OVER 56*, MUST 5E INDEPENDENTLY' SUPPORTED. PARTITIONS GREATER THAN 61 TALL NEED • INDEPENDENT IMAGING YIA SPLAY WIRES (SEPARATE FROM ANY OTHER LIIIRES). PARTITIONS 6' OR LESS NO ATTACHMENT IS • RE4UIRED. 4) 6) SPRINKLER HEAD PENETRATIONS MUST HAVE 2" ovERSIZED TRIM TO ALLOW I" MOVEMENT IN ALL DIRECTION. MANUFACTURER CERTIFICATION OF COMPONENT PERFORMANCE AND PERIODIc SPECIAL INSPECTION OF ANCHOR SYSTEM RIORECIBISIEP.AREAS EXCEEDING 2500 SF, A SEISMIC SEPERATION JOINT OR FULL HEIGHT WALL PARTITION THAT !BREAKS THE CEILING SHALL 8E PROVIDED. ALL CROSS TEES SHALL SE CAOPAIBLE OF CARRYING THE DESIGN LOAD WITHOUT EXCEEDING DEFLECTION EQUAL TO )44,0 OF ITS SPAN. ALL WIRE TIES ARE TQ BE THREE TIGHT TURNS AROUND ITSELF WITI-IN 3 INC. IRESTRAINEP CILING DETAILS (MEETS I5C 2012 SEC 808 AND A5111 C (o35 ASTM C 636 •MP ASCE 1-02) • SCALE TYFES EX. GAS UNIT HEAT (SUSP, FROM CEIL.) 2 IC R4TED COMPACT FLUORESCENT FixTuRES AT 25 WATTS EACH. 303' 23'- 23' - WAREHOUSE OPEN TO \ STRUCTURE AE3OVE j BLDG. SPRINK: RISER NEW GYP BD CEILING ON 6" X 20 GA STEEL STUDS, WITH R-49 INSULATION AIBOv PROVIDE EXHAUST FAN TO OUTSIDE WAREHOUSE / OPEN TO STRUCTURE ABOVE PROVIDE MAX WATTS PER SF WITH OCUPANCY SENSORS (MOTION) TO MEET CODE // 22'-8" 24'-2" •• 22' 303'— 11 REFLECTED CE LING PLAN. - N NORTH SCALE: 1/a" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 1 8 2013 PERMIT CENTER C:\Documents and Settirgs\AII Users\Docunients\CAD \2011\1118 AIRFIELD BUSINESS (9931)\9124\T-1-.dwg, T- 14 0 3 2. :04