Loading...
HomeMy WebLinkAboutPermit D13-0357 - ALLY BAY HEALTH & WELLNESS - TENANT IMPROVEMENTALLY BAY HEALTH & WELLNESS INC 17100 SOUTHCNETER PKWY suri1E 136 D13-0357 Parcel No: Address: • Citv of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 • Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 7888920020 Permit Number: 17100 SOUTHCENTER PKWY 136 Issue Date: Permit Expires On: Project Name: ALLY BAY HEALTH & WELLNESS INC 013-0357 4/21/2014 10/18/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE, WA, 98006 BEN LOUIS 3614 45 AV NE , TACOMA, WA, 98422 OWNER AFFIDAVIT- BEN LOUIS 1// Phone: (253) 709-2606 Phone: License No: Expiration Date: Lender: Name: Address: COLUMBIA BANK 500 BROADWAY, SUITE 380, VANCOUVER, WA, 98660 DESCRIPTION OF WORK: NEW TENANT: TENANT IMPROVEMENTS FOR NEW DAY SPA FACILITY. DEMISE EXISTING TENANTS IMPROVEMENTS AND ADD NEW ROOMS & FACLITIES PER PLAN. Project Valuation: $75,000.00 Fees Collected: $2,064.11 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: • • Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: (2.1 Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the 9pditions attached to this permit. Signature: Print Name: z-OUr S Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 2: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 3: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 4: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 5: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) • • 6: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 7: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 8: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 9: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 10: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 11: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 12: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 13: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 14: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2328. 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 16: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 18: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 19: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 22: ***BUILDING PERMIT CONDITIONS*** 23: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 24: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 25: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 26: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 27: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 28: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. • 29: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 30: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 31: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4 -inches shall be maintained above the controls with the strapping. 32: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 33: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 34: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 35: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0406 SUSPENDED CEILING • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukvvilaW A. gov • Building Permit No.. u1_3--0 Project No. Date Application Accepted: 1 1-^ O'2 t '3 Date Application Expires:, b"' - **-i (For office use onit) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Southcenter Square -17100 Southcenter Parkway, Suite 136, Tukwila, WA 98188 17100 Southcenter Parkway King Co Assessor's Tax No.: Site Address: Tukwila, WA 98188 Suite Number: 136 Tenant Name: Ally Bay Health & Wellness Inc. PROPERTY OWNER Name: Name: WIG Properties LLC - SS Address: Address: 4811 - 134th Place SE City: Tacoma State: WA Zip: 98422 City:Bellevue State: WA Zip: 98006 CONTACT PERSON — person receiving all project communication Name: Ben Louis Address: 3614 45th Avenue NE City: Tacoma State: WA Zip: 98422 Phone: 253 709 2606 Fax: Email: BLOUIS@HANDANDSTONE.COM GENERAL CONTRACTOR INFORMATION Company Name: TBD Architect Name: KATIE MCGOUGH Address: 5209 Lake Washington Blvd. NE Suite 200 City: Kirkland State: WA Zip: 98033 Address: Email: kmcgough@fhoarch.com City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docv Revised: August 2011 bh Floor: New Tenant: ® Yes ..No ARCHITECT OF RECORD Company Name: Freiheit & Ho Architects, Inc., P.S. Architect Name: KATIE MCGOUGH Address: 5209 Lake Washington Blvd. NE Suite 200 City: Kirkland State: WA Zip: 98033 Phone: (425) 827-2100 Fax: (425) 828-6899 Email: kmcgough@fhoarch.com ENGINEER OF RECORD Name: Columbia Bank Company Name: City: Vancouver State: WA Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or. greater per RCW 19.27.095) Name: Columbia Bank Address: 500 E. Broadway, Suite 380 City: Vancouver State: WA Zip: 98660 toRf Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 75,000 Describe the scope of work (please provide detailed information): Existing Building Valuation: $ $33,887,600 s 2 LS t , � (-2,--ti 15 1Vyr cl e,---/ e--7 a� d cad ne {co r'IS 4 �;eS CSP ��s�. d4ac✓ .-t< Will there be new rack storage? Yes g ❑ ®.. No [f yes, a separate permit and plan submittal will be required. Provide All, Building Areas in Square Footage Below 1S1.Floor 43,965 S.F. Interior Remodel 2,664 S.F. Addition to Existing Structure Type of Construction per IBC TYPE V -B Type of Occupancy per IBC B - Business 2nd Floor 3rd Floor Floors thru Basement ..................... Accessory; Structure* Attached Garage I etached Garage Attached Carport Detached carport Covered Deck Uncovered' .Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers ® Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system. provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications \Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: ,C:7. Signature: Date: 11/22/2013 Print Name: Ben Louis Day Telephone: 253.709.2606 Mailing Address: 3614 45th Avenue NE Tacoma WA 98422 City State Zip H:\Applications\Forms-Applications On Line12011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY I PAID PermitTRAK $2,064.11 D13-0357 ' - Address: 17100 SOUTHCENTER PKWY 136 Apn: 7888920020 $2,064.11 DEVELOPMENT $2,064.11 PERMIT FEE R000.322.100.00.00 $1,248.25 PLAN CHECK FEE R000.345.830.00.00 $811.36 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TOTAL FEES PAID BY RECEIPT: R178 $2,064.11 Date Paid: Friday, November 22, 2013 Paid By: BEN LOUIS Pay Method: CREDIT CARD 06047B Printed: Friday, November 22, 2013 2:32 PM 1 of 1 cRWSYSTEMS C(/ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206)431-3670 Permit Inspection Request Line (206)431-2451 o3. 7 Project: il LLy 6A tt Hc41,7+-1 Type of Inspection: 4-3--/1 6 1, Address: (7100 S O , Pw 44 Date Called: Special Instructions: Date Wanted: �,/ 0 ---Lt'. 3 1-P l p.m. Requester: Phone No: 253-0-&Z.:77 Approved per applicable codes. • Corrections required prior to approval. COMMENTS: qe (X/01 NJC { 1`lri01/ / • L raVe�% Insp tor: 44t0_1 I 1O\vNs-^0 F s t Date: r7 -31-1y R1 \ 1 J EINSPECTION FEE R4QUIRED. Prior to next inspection, fee must be V at 6300 SouthcentBlvd., Suite 100. Call to schedule reinspection. i\ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 DA9 r��'ALrFiQA TypeProjectof Inspection: :- a p vecy-lr,a fil I--, NAL -- Add : S - I co (-@ P uci Date Called: Special Instructions: t; r Date__W ted l� at. a.m. Requester: Phone No: LJApproved per applicable codes. &J Corrections required prior to approval. COMMENTS: _ / MPch fors' C‘rJ711— — tJeSe. C a p vecy-lr,a fil I--, NAL -- kic.c AFC N. In cto: REINSPECTION FEE REQUIRED. Prior to ndxt inspection. fee must be paidtat 6300 Southcenter Blvd Suite 100. Call to schedule reinspection. Dat: t� i INSPECTION NO. INSPECTION RECORD Retain a copy with permit ar t3 -O3 5% PERMIT NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: 'kLL`i 6 Pct -F ALT -11 It IPi > Type of Inspection: t. (c.c5 4bet>ef it 1,\JG Address: Date Called: ;--T� SpecialInstructions: Date Wanted: (4c i1lZ�I� a:rn. :or Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: „ . a ,bp{,AV3 Dater REINSPECTION FEE RQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:_ A--` t\ 1\)9 � s' t -------0-1- "'V � Type of Inspection: = RA- AA K) v Address:l (�`' ` Date Called: Special Instructions: Date W rated: _ a.m: -11 Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 7- i I'I?AmoiJ67 ' ivUJA./ev s ut�eQ"f 1 C) €I, R_'A4L e► rP Cr. i.0.lU w Date: 5—I NSPECTION FEE RE t UIRED. Prior to next inspection. fee must be at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1/3 - v3S7 1g--V-C7 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Pro j ct: ._—:- Fire Alarm: Tygg o Inspection: Monitor: Address: /-) i 0 v Suite #: a 3(0 s...� . c, kPlCi Contact Person: Special Instructions: Phone No.: roved per applicable codes. Corrections required prior to approval. COMMENTS: -�� - vrcaV Ot Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Az"54,,tea- Date: 7/ 3'1 /e/ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 3- b 357 —o?� PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Pro ct: �i9r� �j /0-e,5 Fire Alarm: I - L41 4-$4,- St— Type of Inspection: P' Gov -e,e /- b ra 1✓.-- Address: / 7/ 00 Suite #: i 30 5 •C. PK -LA/ ‘ 1 Contact Person: Special Instructions: - ok. ,. Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: I - L41 4-$4,- St— A 08=46 — ;30 -/950 — a-3 Permits: Occupancy Type: 1-7764, fr,,,,-- , ey‹ 5"p c", - ok. ,. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:/54i 6., 5-0_, Date: 6.2f/7 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 I INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit -6'93 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:/6 *ZVile /47d Sprinklers: Type of Inspection: Address: Suite #: / WOO ?6,t, l3 L Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: ,-- Z4 ell 'vQ`r.e .5;/We Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: inspecto ,4 5) Date: 57/ vb V Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • PLAN REVI�W/R=plumy UTING SLIP ACTIVITY NUMBER: D13-0357 DATE: 11-22-13 PROJECT NAME: ALLY BAY HEALTH & WELLNESS SITE ADDRESS: 17100 SOUTHCENTER PY, SUITE 136 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued KDEPARTMENTS:EP ing inc Divi 1 blit Wor C Fire Prevention R Structural niJ u.2.11' Planning ivision Permit Coordinator r DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-26-13 Complete Comments: Incomplete Not Applicable Permit,Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please RouterXrStructural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: n Approved with Conditions tc DUE DATE: 12-24-13 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665 Permit Center/Building Division 206 431-3670 Public Works Department 206 433-0179 Planning Division 206 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) COUNTY OF KING ) ss. Loui, [please print name] , states as follows: PERMIT NO: 3--a37V7 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requireme9t of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number //, and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction -week. Owner/Own r s Agen Signed and sworn to before jme this day of 17'► I , 20 / V. 41101 OT RY PUBLIC id for the State f Washington na Residing at l�ca' Name as commissioned: My commission expires: , County e5P//c( 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity whoeholds,ea�,vali0,electr>ical contractor's license under chate9:2$ RCWrt}iat;employs a certified journeyman elecrician;'a certified residential specialty electrician, or ar electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidei ally, directly,'and immediately appropriate to theiliWin-kind:replace`nient`of a household appliance or other mals ousehold utilization equipment that requires limited electnGpower and'limited waste and/or water connections`"Arifelectiical trainee must be supervised by a certified electrician while performing plumbing work. " Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. GENERAL NOTES GENERAL NOTES, CONT. PROJECT DATA DRAWING INDEX GENERAL NOTES: I. ALL CONSTRUCTION SHALL COMPLY WITH THE 2012 INTERNATIONAL BUILDING CODE AS ADOPTED BY THE CITY OF TUKWILA, STATE REGULATIONS FOR BARRIER FREE DESIGN, WASHINGTON STATE ENERGY CODE, AND ALL APPLICABLE LOCAL CODES, ORDINANCES, AND STANDARDS. IN CASE OF ANY CONFLICT WHERE THE METHODS OR STANDARDS OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL GOVERN. NOTIFY THE ARCHITECT OF ALL CONFLICTS. 2. SECURE RELEVANT CITY AND STATE APPROVALS RELATING TO FIRE, CONSTRUCTION, LABOR, HEALTH AND LICENSING. CONTRACTOR SHALL FURTHER POST ALL BONDS AND SECURE ALL INSURANCE REQUIRED BY LAW OR CONTRACT, FORWARDING PROOF OF SUCH ACTIONS TO THE LANDLORD PRIOR TO COMMENCEMENT OF CONSTRUCTION. 3. PROVIDE ALL NECESSARY PERMITS AND FEES, WITH THE EXCEPTION OF THE BUILDING PERMIT, WHICH WILL BE PROVIDED BY THE OWNER. 4. WORK NOT INCLUDED IN THIS CONTRACT SHALL BE MARKED "N.I.G." OR SPECIFICALLY ASSIGNED TO ANOTHER PARTY. 5. CONTRACTOR SHALL VISIT THE SITE, REVIEW THE DRAWIN65 AS SUBMITTED BY THE ARCHITECT, AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO BIDDING OR CONSTRUCTION. 6. ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURERS LATEST RECOMMENDATIONS OR WRITTEN DIRECTIONS. 7. SUBMIT A LIST OF PROPOSED PRODUCT SUBMITTALS AND SHOP DRAWINGS TO THE OWNER FOR APPROVAL PRIOR TO START OF CONSTRUCTION. 8. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. q. WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR, IT 15 INTENDED THAT SUCH SHALL APPLY TO A5 MANY SUCH DEVICES, ITEMS OR PARTS A5 ARE REQUIRED TO PROPERLY COMPLETE THE WORK. 10. VERIFY ALL "BUILDING STANDARDS" WITH BUILDING OWNER PRIOR TO BEGINNING ANY WORK. HOWEVER, THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY, AND HOLD THE ARCHITECT HARMLESS FROM ANY CLAIMS ARISING A5 A RESULT OF UNAPPROVED CHANGES. II. ALL PRODUCTS AND MATERIALS SPECIFIED IN THE DRAWINGS (WITH EXCEPTION TO SPECIFIC FINISH COLORS AND FLOORING) ARE INTENDED TO BE ON AN ''OR EQUAL" BASIS. ANY PROPOSED SUBSTITUTIONS NJJST BE SUBMITTED TO THE ARCHITECT IN WRITING FOR APPROVAL WITHOUT DELAY OF SCHEDULE. 12. LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THIS WORK. 15. VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS OTHERWISE NOTED IN THE PLANS OR SPECIFICATIONS. 14. ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A GLEAN (BROOM) CONDITION AT ALL TIMES. 15. PROTECT ADJACENT WORK AND REPAIR ANY DAMAGE AT CONTRACTOR'S OWN EXPENSE. 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH ALL APPLICABLE SAFETY CODES. 17. THE CONTRACTOR SHALL INDEMNIFY AND HOLD THE BUILDING OWNER/ARGHITEGT/EN6INEER HARMLESS FOR INJURY OR DEATH TO PERSONS OR FOR DAMAGE TO PROPERTY CAUSED BY THE NEGLIGENCE OF THE CONTRACTOR, HI5 AGENTS, EMPLOYEES, OR SUBCONTRACTORS. 18. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKERS. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS WELL AS ALL REVISIONS, ADDENDA, AND';GHANSE ORDERS. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. lq. MAINTAIN ALL EXIT PATHWAYS DURING CONSTRUCTION. 20. PROVIDE COMPLETE SECURITY OF THE TENANT SUITE WHILE JOB I5 IN PROGRESS AND UNTIL THE JOB 15 COMPLETED. 21. AT COMPLETION OF THE WORK, REMOVE ALL DEBRIS FROM THE SITE, LEAVING SPADE GLEAN, WASH ALL NEW WINDOWS AND GLASS, POLISH ALL NEW OR REWORKED HARDWARE. REPLACE AND PATCH AREAS OF CEILING DAMAGED DUE TO LIGHTING INSTALLATION OR MECHANICAL ADJUSTMENT. 22. ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE (I) YEAR AFTER COMPLETION, UNLESS OTHERWISE SPECIFIED, AND SHALL BE 50 STATED IN CONTRACTOR'S WRITTEN PROPOSAL AND AGREEMENT. ALL REPAIRS, CORRECTIONS, DISCREPANCIES, ETC., MUST BE MADE WITHOUT ANY ADDITIONAL COST TO TIME OWNER, AND WITHIN FIVE (5) DAYS AFTER NOTICE 15 GIVEN. 23. MINIMIZE DISRUPTIONS OF BUILDING OCCUPANTS DUE TO NOISE, ODOR, FUMES, OR VIBRATION. AT THE END OF CONSTRUCTION THE CONTRACTOR SHALL COMPLETELY GLEAN ALL AREAS SOILED BY CONSTRUCTION ACTIVITIES INCLUDING THOSE IN WHICH NO WORK WAS DONE. 24. LATHING, PLASTER, AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO CHAPTER 25 OF THE 2012 I.B.G. 25. USE GYPSUM WALL BOARD WOOD TRIM AT ALL CORNERS AND INTERSECTIONS; PAINT TO MATCH ADJACENT WALL. 26. ALL GLASS AND GLAZING' SHALL COMPLY WITH CHAPTER 24 OF THE 2012 INTERNATIONAL BUILDING CODE AND THE U.S. PRODUCT SAFETY COMMISSION: SAFETY STANDARDS FOR ARCHITECTURAL GLAZING MATERIALS (42 FR 1426: 16 GFR PART 1201). 21. VERIFY ALL DOOR AND WINDOW ROUGH OPENING, DIMENSIONS WITH DOOR AND WINDOW MANUFACTURERS. 28. DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONSTRUCTION DRAWING SHOULD BE GALLED TO THE ATTENTION OF THE ARCHITECTS.. DIMENSION: I. ALL INFORMATION SHOWN ON THE DRAWIN65 RELATIVE TO EXISTING CONDITIONS 15 GIVEN A5 THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR CONDITIONS ADVERSELY ATTECTING THE DESIGN PRIOR TO PROCEEDING WITH THE WORK. 2. DIMENSIONS OF PLANS ARE TYPICAL TO THE CENTERLINE OF COLUMNS AND FINISHED 611B. FADE OF PARTITIONS, UNLESS NOTED OTHERWISE. DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS ARE TO BE FOUR (4) INCHES FROM THE FACE OF THE ADJACENT PARTITION OR CENTERED BETWEEN PARTITIONS. 3. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY THE ARCHITECT IF DISCREPANCIES ARE FOUND. CONTRACTOR SHALL CONSULT OWNER'S REPRESENTATIVE WHEN ADDRESSING QUESTIONS OF MATERIAL, METHODS, DETAIL OR WORKMANSHIP NOT COVERED IN THE CONTRACT DOCUMENTS. 4. CONSTRUCT WALLS PLUMB AND SQUARE WITH EXISTING STRUCTURE AND NEW CONSTRUCTION UNLESS NOTED OTHERWISE. S. COORDINATION: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION AND COORDINATION OF THE WORK OF ALL TRADES TO ASSURE COMPLIANCE WITH THE DRAWINGS. 6. ANY DEVIATIONS FROM DIMENSIONED LOCATIONS MUST BE APPROVED BY THE ARCHITECT. FIRE PROTECTION: 1. IF NECESSARY, PROVIDE FIRE PROTECTION AT ALL PENETRATIONS OF FIRE RELATED ELEMENTS AS REQUIRED BY CODE. 2. FIRE EXTINGUISHERS: VERIFY LOCATION, TYPE, AND SIZE PER FIRE MARSHALL REQUIREMENTS. CONTRACTOR TO PROVIDE ALL TEMPORARY AND PERMANENT FIRE EXTINGUISHERS REQUIRED UNDER N.F.P.A. 10 MOST REGENT EDITION AND APPROVED BY THE FIRE MARSHALL. CONFIRM ACCEPTABILITY OF LOCATION WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. PROVIDE FINISHED CABINETS TO MATCH BUILDING STANDARD FOR EXTINGUISHERS AT ALL EXPOSED LOCATIONS. 3. FIRE EXTINGUISHERS AND CABINETS SHOULD BE LOCATED 50 THAT THE TOP OF THE EXTINGUISHER OR CABINET 15 NO HIGHER THAN 48" A.F.F. AND THE TOP OF THE EXTINGUISHER OR CABINET HANDLE 15 AT LEAST 56" A.F.F. 4. AT SEMI -RECESSED FIRE EXTINGUISHER CABINETS WRAP ADDITIONAL LAYER(5) OF TYPE 'X' GYPSUM WALL BOARD INTO THE CABINET CAVITY TO MAINTAIN SPECIFIED FIRE RATED REQUIREMENT. REFER TO WALL CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. 5. PROVIDE AND INSTALL FIRE EXTINGUISHER SIGNAGE (5"X6") ABOVE EACH FIRE EXTINGUISHER OR CABINET WITHIN THE SCOPE OF THE TENANT IMPROVEMENT. MOUNT AT 84" A.F.F. UNLESS OTHERWISE REQUIRED. 6. EXIT SIGNS AND EXIT ILLUMINATION SHALL CONFORM TO THE 2012 I.B.G. AND TUKWILA FIRE MARSHALL REQUIREMENTS. CONTRACTOR TO PROVIDE AND INSTALL EMERGENCY LIGHTING AND EXIT LIGHTING A5 REQUIRED BY THE TUKWILA FIRE AND BUILDING DEPARTMENTS. CONFIRM ACCEPTABILITY OF LOCATIONS WITH OWNER'S REPRESENTATIVE BEFORE INSTALLATION. CONTRACTOR SHALL PROVIDE AND INSTALL AUDIBLE ALARMS IN ACCORDANCE WITH I.S.G. ARTICLE g. CONTRACTOR SHALL PROVIDE AND INSTALL VISIBLE ALARM SIGNALS AS REQUIRED BY ADA GUIDELINES. CONTRACTOR SHALL PROVIDE AND INSTALL ALL SMOKE DETECTORS AND SMOKE DETECTION AS REQUIRED UNDER ARTICLE q OF THE IB.G. THE INSTALLATION OF THE ABOVE NOTED SYSTEM SHALL INCLUDE THE CONNECTION TO AND/OR MODIFICATION OF THE EXISTING BUILDING SYSTEMS, AS NECESSARY. 7. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 8. FLAMMABLE LIQUIDS SHALL NOT BE PLACED, STORED, OR DISPENSED IN THIS OCCUPANCY EXCEPT AS PROVIDED IN N.F.PA. STANDARD 30 AND THE 20044 INTERNATIONAL FIRE CODE. PERMIT MAY BE REQUIRED. q. ALL DRAPES, HANGINGS, CURTAINS, AND ALL OTHER DECORATIVE MATERIAL, INCLUDING CHRISTMAS TREES THAT WOULD TEND TO INCREASE THE FIRE AND PANIC HAZARD SHALL BE MADE FROM NONFLAMMABLE MATERIAL, OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT CONDITION BY MEANS OF A FLAME RETARDANT SOLUTION OR PROCESS APPROVED BY THE FIRE MARSHALL. PROVIDE A CERTIFICATION TO THIS CTTCCT. EXIT DOORS, EXIT LIGHTS, AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONGEALED OR. OBSTRUCTED BY ANY DECORATIVE MATERIAL. MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISHES SHALL BE PER TABLE 803.1, SECTION 805.1 OF THE 2012 INTERNATIONAL BUILDING CODE. 10. ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE SPECIFIC RATIN. II. ADD AND/OR RELOCATE LIFE SAFETY DEVICES AS NECESSARY PER BUILDING CODE. 12. A FIRE SAFETY AND EVACUATION PLAN WILL BE PROVIDED PER IFC 404 BY TENANT/OWNER. CONSTRUCTION: I. INVESTIGATE AND VERIFY LOCATIONS OF EXISTING STRUCTURAL, PLUMBING, MECHANICAL, AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS AND NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 2. COORDINATE CONSTRUCTION SCHEDULING WITH TENANT AND BUILDING REPRESENTATIVE TO ALLOW ONGOING, OPERATION OF THE FACILITY DURING CONSTRUCTION. 3. PROVIDE FIRE TREATED BLOCKING AS REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. 4. THERE SHALL BE NO EXPOSED PIPE, CONDUITS, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL BE CONGEALED OR FURRED AND FINISHED, UNLESS NOTED A5 EXPOSED ON CONSTRUCTION DRAWINGS. 5. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. 6. PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS. 1. "PATCH AND REPAIR ALL EXISTING SURFACES AS REQUIRED BY DEMOLITION AND NEW CONSTRUCTION TO RECEIVE NEW SCHEDULED FINISHES. ALL SURFACES ARE TO HAVE "LIKE -NEW" APPEARANCE. 8. STUD HEIGHT AND SPACING LIMITATION OF STEEL FRAMING COMPONENTS SHOULD BE IN COMPLIANCE WITH ASTM G 154 FOR MAXIMUM DEFLECTION AND MINIMUM LATERAL LOADING REQUIREMENTS. q. ALL DEMOLISHED MATERIALS TO BE RECYCLED TO AN APPROVED RECYGLER. 11. STUD HEIGHT AND SPACING LIMITATION OF STEEL FRAMING COMPONENTS SHOULD BE IN COMPLIANCE WITH ASTM G 154 FOR MAXIMUM DEFLECTION AND MINIMUM LATERAL LOADING REQUIREMENTS. PLUMBING. MECHANICAL 4 ELECTRICAL: 1. PLUMBING, MECHANICAL, 4 ELECTRICAL DRAWINGS ARE TO BE SUBMITTED UNDER SEPARATE PERMIT. 2. MECHANICAL 4 ELECTRICAL CONTRACTORS SHALL BE RESPONSIBLE TO MAINTAIN COMPLIANCE WITH APPLICABLE CODES AND STANDARDS AND OBTAIN ALL NECESSARY PERMITS AND APPROVALS. 5. ANY DEVIATIONS FROM DIMENSIONED LOCATIONS MIDST BE APPROVED BY THE ARCHITECT. 4. DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONSTRUCTION DRAWING SHOULD BE GALLED TO THE ATTENTION OF THE ARCHITECTS. 5. REFLECTED CEILING PLAN 15 FOR THE GENERAL INFORMATION OF THE CONTRACTOR EXACT LOCATIONS SHOULD BE VERIFIED. 6. ALL CABLING AND WIRING NOT IN CONDUITS OR FULL SURROUND GABLE TRAYS SHALL HAVE A FLAME SPREAD RATING OF LESS THAN 25 AND A SMOKE DEVELOPMENT RANGE OF LESS THAN 50. 7. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE BIDDER DESIGN/BUILD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE CORRESPONDING PERMITS FOR WORK. THE PROPOSED SYSTEM DESIGN 4 METHOD OF OPERATION FOR ALL ROOMS SHALL BE REVIEWED AND APPROVED BY THE TENANT PRIOR TO THE START OF ANY WORK. 8. WHERE APPLICABLE, STRUCTURAL, PLUMBING, MECHANICAL, ELECTRICAL, AND FIRE PROTECTION DRAWINGS ARE SUPPLEMENTARY TO THESE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ALL DISCREPANCIES BETWEEN THE CONSULTANTS' DRAWINGS WITH A WRITTEN REQUEST FOR CLARIFICATION. ANY WORK INSTALLED IN CONFLICT WITH 11 CZ DRAWINGS OR SPECIFICATIONS SHALL BE CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO THE BUILDING OWNER, TENANT, OR ARCHITECT. CEILING: I. RELOCATE SPRINKLER HEADS AS REQUIRED BY NEW CONSTRUCTION. SPRINKLER REVISIONS UNDER A SEPARATE PERMIT. J=WISH AND MATERIALS: I. SUBMIT FINISH SAMPLES TO TENANT FOR APPROVAL PRIOR TO ORDERING MATERIALS. 2. INTERSECTION OF SCHEDULED FLOORING MATERIALS ARE TO OCCUR AT CENTERLINE OF DOOR WHEN IN A FULLY CLOSED POSITION UNLESS NOTED OTHERWISE. 3. PROVIDE APPROPRIATE TRANSITION MATERIAL AS REQUIRED WHERE DISSIMILAR FLOORING MATERIALS INTERSECT. DOOR: I. ALL DOOR HARDWARE TO MEET REQUIREMENTS OF 2012 INTERNATIONAL BUILDING CODE 141/ WASHINGTON STATE AMENDMENTS AND OWNER'S BUILDING REQUIREMENTS. LEVER HANDLES ARE REQUIRED IN ALL PUBLIC AREAS. 2. COORDINATE: ALL KEYING REQUIREMENTS WITH OWNER/TENANT. CONTRACTOR SHALL PROVIDE ALL LOGKSET CYLINDERS TO MATCH OWNER STANDARD. CONTRACTOR SHALL RE -KEY ALL DOORS TO MEET OWNER'S REQUIREMENTS. PROJECT ADDRESS: PROJECT OWNER: PROJECT ARCHITECT: CONTRACTOR: AUTHORITY: OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: NUMBER OF STORIES: TAX PARCEL NUMBER: BUILDING AREA: IMPROVEMENT AREA PER PERMIT: SCOPE OF WORK: VALUATION: 11100 SOUTHCENTER PARKWAY BUILDING 14, SUITE 136 TUKWILA, WA g8188 HAND 4 STONE MASSAGE AND FACIAL SPA 200 HORIZON DRIVE - SUITE 203 HAMILTON, NJ 08611 PHONE: 604-581-41800 X204 CONTACT: NICK MALONE FREIHEIT 4 H0 ARCHITECTS, INC., P.S. 5201 LAKE WASHINGTON BLVD 1E, SUITE 200 KIRKLAND, WA .18053 PHONE: (425) 821-2100 FAX: (425) 828-68441 CONTACT: KATIE MGGOU&H TBD CITY OF TUKWILA B (BUSINESS) TYPE V -B (FULLY SPRINKLED) I STORY 788842-0020 45,q65 S.F. 2,664 5.F. TENANT IMPROVEMENTS $15,000 A0.00 GENERAL NOTES, PROJECT DATA, VICINITY MAP, DRAWING INDEX AI.00 CODE PLAN A2.00 SITE PLAN (POR REFERENCE ONLY) A3.00 DEMOLITION PLAN A3.0I FLOOR PLAN A6.00 ELEVATIONS 4 DETAILS A6.0I ELEVATIONS 4 DETAILS A7.00 REFLECTED GEILIN PLAN A4.00 DOOR SCHEDULE AND DETAILS E1.00 ELECTRICAL PLAN FI.00 FLOOR FINISH PLAN SEPARATE PERMIT REQUIRED FOR: Mechanical Etectricat Iumbing as Piping City of Tukwila BUILDING DIVISION DEFERRED SUBMITTALS VICINITY MAP N.TS. I. ELECTRICAL SYSTEM WORK 2. HVAC SYSTEM (DUCTING, DISTRIBUTION AND CONTROLS) 3. PLUMBING SYSTEM WORK 4. FIRE SPRINKLER SYSTEM (SYSTEM TO MEET N.F.PA. STANDARD 13 AND IBC CHAPTER g) 5. LIFE SAFETY SYSTEMS (HORNS, STROBES AND FIRE ALARM IMPROVEMENTS) No changes shall be made to the of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. DESIGN CODES TYPICAL ABBREVIATIONS AB ACT AFF ALUM BD BLDG BOT BR& GAS GFT OJT AT POUND OR NUMBER ANCHOR BOLT ACOUSTICAL CEILING TILE ABOVE FINISH FLOOR ALUMINUM BOARD BUILDING BOTTOM BEARING CABINET CERAMIC FLOOR TILE CONTROL JOINT CENTER LINE GLG CEILING GMU CONCRETE MASONRY UNITS COL COLUMN GONG CONCRETE GONSTR CONSTRUCTION CONSTR JT CONSTRUCTION JOINT DONT CONTINUOUS CONTR GT DET DIM DN D5 EA EB ELEG ELEV EQ EQUIP EXIST EXP JT EXT FDN FIN FL CONTRACT(OR) CERAMIC TILE DETAIL DIAMETER DIMENSION DOWN DOWNSPOUT EACH EXPANSION BOLT ELECTRICAL ELEVATION EQUAL EQUIPMENT EXISTING EXPANSION JOINT EXTERIOR FOUNDATION FINISHED) FLOOR FT FTG, FUR GA GALV 6G 6L 6JNA. HG HDWR HM INSUL INT JT MAX MEGH MIL MFR MIN NTS OG P PLYWD RD REINF RF6 RM RO SEG SIM SPEC 5Q STL T413 TYP V.I.F. FOOT OR FEET FOOTING, FURRING GAUGE GALVANIZED GENERAL CONTRACTOR GLASS GYPSUM WALLBOARD HOLLOW GORE HARDWARE HOLLOW METAL INSULATION INTERIOR JOINT MAXIMUM MECHANICAL METAL MANUFACTURER MINIMUM NOT TO SCALE ON CENTER PROPERTY LINE PLYWOOD ROOF DRAIN REINFORGE(D)(ING) ROOFING RM ROUGH OPENING SECTION SIMILAR SPECIFICATION SQUARE STEEL TOP AND BOTTOM TYPICAL VERIFY IN FIELD WITH WD WOOD W/O WITHOUT ARB/A.B. WEATHER RESISTIVE BARRIER/ AIR BARRIER WSGT WAINSCOT 2012 INTERNATIONAL BUILDING CODE, WAG 51-50 (INCLUDING THE 2012 INTERNATIONAL EXISTING BUILDING CODE) 2012 INTERNATIONAL MECHANICAL CODE, WAG 5I-52 (INCLUDING 20041 INTERNATIONAL FUEL GAS CODE) 2012 INTERNATIONAL FIRE CODE, WAG 51-54 2012 UNIFORM PLUMBING CODE, WAG 51-56 AND 51-57 (UPC) 2012 WASHINGTON STATE: ENERGY CODE 2012 ICG AII7.1 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 10 2013 WiL City of Tukwila BUILDING DIVISION FLECJJVFr NOV 2 O 2013 TUKv�I►- PUBLIC WORKS 1N-3 0 35 7 RECEIVED CITY OF TUKWILA NOV 2 2 2013 PERMIT CENTER Mk: 41 h 4. W. NI U :z ierg nti� Qt Cc'a w ro rm al al 0 H1N 0 .4441 = 043W ilM. xa` REV DESCRIPTION CHECK SET PERMIT SET Y,IArchitectural Projects113131A13-35215 CURRENT PHASE DWGS12 Sheets1A13-352 A0.00.dwg Nov 18, 2013 - 2:28pm kmcgough A0.00 DATE 11104113 11119113 PROJECT NUMBER: A13-3511118113 ® FREIHEIT & HO ARCHITECTS, INC., P.S. /1'-6)(EXIT I3.5 OGGUPANTS REQUIRE* EXIT WIDTH: 21" I PRTVIDED: 36" 1 1 EXIT FE L TREATMENT ROOM #1 (BUSINESS) 415 S.F. / 100 = I OCCUPANT (I) EXIT REQUIRED TREATMENT RO2 1 1103 1 (BU INE%) qq F. / 100 I 0 GUPANT (I) EX111 RREQUIR F CIAL ROOM .#1 (BUSINESS) qq S.F. / 100 = I OCCUPANT (I) EXIT REQUIRED FICIAL R(tOM #2 101 (BUSINESS) q6 S.F. / 100 = I OCCUPANT (I) EXIT REQUIRED 1 — — BREAKROOM 107 (BUSINESS) 3055.F./100 = 4 OCCUPANTS (I) EXIT REQUIRED IE IT !s> 0 ,— (STORAGE) II S.F. / 300 = I OCCUPANT (I) EXIT REQUIRED STORAGE 109 (STORAGE) 20 S.F. / 300 = I OCCUPANT (I) EXIT REQUIRED STORAGE 108 LONGEST COMMON II PATH OF TRAVEL DISTANCE = 32'-2" COUPLES TREATMENT 112 (BUSINESS) Iqq S.F. / 100 = 2 OCCUPANTS (I) EXIT REQUIRED r-- 1'-6" �SjaRaG1 I EXIT ; II S.F. /'300 I (I) EXI REQUIRFD ��II m ,I 1– E T1 _1 1 I'-6" TREATM NT ROOM 3 (EN/SINEW) 102 S.F. / 100 = 2 OCCUPANTS (I) EXIT REQUIRED I'-6" TREATM ROOM NT (BUSINESS) 101 S.F. / 100 = 2 OCCUPANTS (I) EXIT REQUIRED 4 FACIAL ROOM #n -145 (BUSINESS) qq 5.F. / 100 = I OCCUPANT (I) EXIT REQUIRED (BUSINESS) 101 S.F. / 100 = 2 OCCUPANTS (I) EXIT REQUIRED OF -FIDE— — I116 I RECEPTION 100 (BUSINESS) 5410 S.F. / 100 = 6 OCCUPANTS (I) EXIT REQUIRED •r> 13.5 OCCUPANTS REQUIRED EXIT WIDTH: 21" PROVIDED: 12" EXIT k. 4 — (STORAGE) 6 S.F. / 300 = I OCCUPANT (I) EXIT REQUIRED CODE SUMMARY CODE SUMMARY PLAN LEGEND EGRESS SUMMARY: OFFICE: TRAVEL DISTANCE: COMMON PATH OCCUPANCY: REQUIRED: PROVIDED: THEREFORE: 300' MAX. 641'-2" 100' MAX. 52'-2" PER PLAN: 21 OCCUPANTS PLUMBING SUMMARY BUSINESS: REQUIRED: OK AREA CALCULATION WATER CLOSETS LAVATORIES DRINKING FOUNTAINS MALE FEMALE SUITE UNDER 1/13.5 OCCUPANTS= PERMIT: 6.15 OCG. PER GENDER TOTAL REQUIRED: TOTAL PROVIDED: 2 1 2 EXIT EXISTING OR RELOCATED ILLUMINATED EMERGENCY EGRESS SIGN. NEW OR RELOCATED FIRE EXTINGUISHER (MINIMUM 2A10 -BG). PROVIDE (I) EVERY 3,000 5.F., TYPICAL AND NO MORE THAN 75 LINEAR FEET APART. VERIFY LOCATION 15 ACCEPTABLE WITH FIRE MARSHAL. LONGEST TRAVEL DISTANCE LONGEST COMMON PATH OF TRAVEL UNOCCUPIED SPACE bi3o3s7 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 10 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 2 2 2013 PERMIT CENTER Y:1Architectural Projects113131A13-35215 CURRENT PHASE DWGS12 Sheets1A13-352 A1.00,dwg Nov 18, 2013 - 2:27pm kmcgough 0 MS AT SOUTHCENTER S a . To • 1 10401 REGISTERED ARCH SEPH C PAI,,IQFQUIST STATE OF WASHINGTON A1.00 PROJECT NUMBER: A13.3511118113 @ FREIHEIT & HO ARCHITECTS, INC., P.S. .J. r iii DN -06)-7 V TYP. DN -04) NPN -02) DN -OI ) TYP. \-(DN-02) TYP. DN -02) DN -02 O DN -05 TYP. (DN -02)7 TYP. 0 DEMOLITION PLAN SCALE: 1/4" = I'-0" ¥:\Architectural Projects113131A13-35215 CURRENT PHASE DWGS\2 Sheets1A13-352 A3.00.dwg Nov 18, 2013- 2:29pm kmcgough 1 1 DEMOLITION PLAN GENERAL NOTES DEMOLITION PLAN KEYNOTES I. REMOVE ALL EXISTING IMPROVEMENTS AS NECESSARY TO ACCOMMODATE NEW WORK. 2. THIS PLAN SHOWS GENERAL DEMOLITION WORK TO BE PERFORMED AND DOES NOT RELIEVE THE CONTRACTOR FROM OTHER DEMOLITION WORK REQUIRED TO PRODUCE THE BUILDING MODIFICATIONS SHOWN ON THE REMAINING CONTRACT DOCUMENTS. 3. EXISTING SLAB TO BE REPAIRED, FILLED, GLEANED 4 LEVELED TO ACCOMMODATE NEW FINISHES. 4. EXISTING LOW VOLTAGE ELECTRICAL OUTLETS AND CONDUITS NOT SCHEDULED FOR REUSE TO BE REMOVED. REMOVE ALL CONDUIT AND WIRING FROM OUTLET BACK TO ELECTRICAL PANEL. 5. CONTRACTOR SHALL GAP ALL UNUSED PLUMBING, LINES. THIS INCLUDES, BUT 15 NOT LIMITED TO: FLOOR DRAINS, WALL DRAINS, ALL WATER LINES, AND ALL VENT5. LINES IN WALL SHALL BE GAPPED AND SEALED. NO EXPOSED GAPS WILL BE ALLOWED. LINES IN FLOORS SHALL BE REMOVED AND GAPPED BELOW FLOOR LEVEL. FINAL PLUMBING SHALL CONFORM TO ALL CODES. 6. CARE SHALL BE TAKEN DURING DEMOLITION TO PROTECT ALL CONSTRUCTION TO REMAIN. CONTRACTOR SHALL REPAIR OR REPLACE ALL DAMAGED MATERIAL TO A "LIKE -NEW" CONDITION. 1. THE CONTRACTOR SHALL ENSURE THAT THIS PROJECT AND ALL CONSTRUCTION ACTIVITIES RELATED THERETO CONFORM WITH ALL LOCAL, REGIONAL, STATE AND/OR FEDERAL REGULATIONS PERTAINING TO THE DISTURBING, DISPLACING AID/OR REMOVAL OF ASBESTOS OR ASBESTOS CONTAINING MATERIALS. 8. REMOVE ALL EXISTING 5IGNA6E, STICKERS, OR NOTIFICATIONS NOT RELATED TO CURRENT PROJECT FROM EXISTING STOREFRONT AND GLAZING. a. PATCH 4 REPAIR REMAINING G.B. AS REQUIRED TO ACCEPT NEW FINISH. DEMOLISH ALL EXISTING HOOKS, NAILS, SHELVING, ETC. PATCH AND REPAIR AFFECTED 4 ADJACENT WALLS AND CEILINGS TO 'LIKE -NEW' CONDITION. 10. REPETITIVE ITEMS NOT NOTED ON DEMOLITION PLAN SHALL BE REMOVED AS IF NOTED. II. ALL DIMENSIONS SHOWN ARE APPROXIMATE. CONTRACTOR 15 RESPONSIBLE TO FIELD VERIFY AND PERFORM DEMOLITION AS NECESSARY. 12. PROTECT ALL AREAS NOT INCLUDED IN THE WORK AND H.VA.G. SYSTEM FROM DUST AND DEBRIS AT ALL TIMES. ANY DAMAGE THAT OCCURS AS A RESULT OF THE WORK SHALL BE REPAIRED TO A LIKE NEW CONDITION. 13. AS DIRECTED BY BUILDING MANAGEMENT OR THE CONSTRUCTION MANAGER, ALL MATERIALS SHOWN TO BE REMOVED SHALL BE PROTECTED, SAVED, AND REUSED A5 DIRECTED HEREIN OR RETURNED TO BUILDING OWNER OR TENANT. ALL UNWANTED MATERIAL SHALL BE DISPOSED OF. 14. IF THERE 15 ANY QUESTION AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY WITH THE BUILDING MANAGEMENT, OWNER OR ARCHITECT BEFORE PROCEEDING. (DN -01) (DN -02) (DN -o3) (DN -04) (DN -05) (DN -o6) (DN -0'1) EXISTING COLUMN TO REMAIN, TYP. PROTECT FROM DAMAGE. EXISTING WALL TO REMAIN, TYP. PROTECT FROM DAMAGE. REMOVE ALL EXISTING GWB CEILINGS, LIGHTING, AND ANY NON-ESSENTIAL WIRING THROUGHOUT. EXISTING EXIT SIGNS TO BE RELOCATED/ REMAIN. EXISTING ELECTRICAL PANEL TO REMAIN. EXISTING STOREFRONT TO REMAIN, TYP. PROTECT FROM DAMAGE. EXISTING RESTROOM FIXTURES AND ACCESSORIES TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. REMOVE EXISTING FLOORING 4 BASE THROUGHOUT (IF EXISTING). Fo, LEGEND EXISTING STUD WALL TO BE DEMOLISHED EXISTING DOOR TO BE REMOVED EXISTING STUD WALL TO REMAIN EXISTING DOOR TO REMAIN 1 1 bt3o3s REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OE TUKWILA NOV 2 2 2013 PERMIT CENTER 404 111CL MUIR 116 zNw 10401 FS; AT SOUTHCENTER REGISTERED ARC SEPH C PALUIST STATE OF WASHINGTON .0 A3.00 PROJECT NUMBER: A13-3511118113 �, FREIHEIT & HO ARCHITECTS, INC., P.S. (KN-03) (KN -05) (KN -06) (KN -08) (KN -09) (KN -10 ) (KN -I3) (KN -I6 ) (KN -18) �c- 0 •7 EXISTING (V.IP) .J. -F- EN'S RESTROOM y j 106 I \ 6'-7 1/2" +/.3 ,/ ff ri 'STJN6 .I F (KN -I6) KN -0I) (KN -05 II' -3 3/4" A rA ,,-• V \ I fZESTRO f M g WI) I 105 1 \ 1 < ,s (KNE -16 \ I /% 6'-7 I/2" 1 i 4'-3 3/8" A / R78ATMENT ROOM #1 101 0 J PB EAKROOM L_ 107 0 \ X104 • KN -I2 ) A\ II\O/ 10 6'-7 7/8" +/- (KN -04 1041 STORAGE 109 (KN-03� 5'-0 5/8" KN -17 108 STORAG 108 OWN KN-la� • 1- N 0 / \ / / OUPLES / T/REA ENT / / / /I 5'-21/6" +/- -2'-2 1/6" 8'-8 5/8" 11'-6 3/4" 1'-10" 8'-41" 112 t T EATMENT\ ROOM42 103 A / EATM EENT \\ OOM #3\ \\ \ \ 114 I EATME\NT \\ BOOM #4\ \\ \ \ - ACIAL / J \C ROOM #1 / ,( N u • m r in in • A6.00 VACIAL ROOM #2 \ " 101 / L_ OFFICE L 116 713 111 14'-I0 3/8° +/- 5'-5 5 8'-10 7/8" 8'-5 3/4" +/- KN -I5) (KN -08) RECEPTION 18 A6.01 KN -041 (KN -I8 }� (KN -01)-! k O GENERAL NOTES I. PATCH AND REPAIR 6.WB. AS REQUIRED TO ACCEPT NEW FINISH. 2. BRACE NON -LOAD BEARING WALLS PER DETAILS 6 4 10/A6.00. 3. PROVIDE BACKING AT ALL WALL MOUNTED FIXTURES AND EQUIPMENT. 4. PROVIDE THE FOLLOWING REQUIRED CONCRETE POUR BACK AT ALL SLAB BLOGKOUTS, SAWCUTS, AND PATCHES: 4.1. PATCH $ REPAIR EXISTING VAPOR RETARDER AT SLAB POUR -BACK. 42. GORLISS CONCRETE MIX DESIGN NO. JI40104(I) AND FIBER REINFORCEMENT (ULTRAFIBER 500 BY BUCKEYE TECHNOLOGIES INC). MIX DESIGN AND FIBER REINFORCEMENT SPECIFICATIONS ARE AVAILABLE FROM LANDLORD. 4.5. PROVIDE THE FOLLOWING REINFORCING: 04'S AT 18" 0.G. WITH 8" MINIMUM EMBEDMENT INTO NEW SLAB AND 4" MINIMUM EMBEDMENT WITH EPDXY GROUT INTO EXISTING SLAB. 5. COORDINATE CONSTRUCTION SCHEDULE WITH ARCHITECT AND BUILDING OWNER AND MINIMIZE DISRUPTIONS TO BUSINESS HOUR OPERATIONS. WALL TYPES SYMBOL DESCRIPTION 3-5/8" X GA. METAL STUDS ® 16" 0.G. WITH 5/8" TYPE 'X' 6JNB. EACH SIDE AND SOUND BATTS IN CAVITY. SEE 10/A6.00. 3-5/8" X GA. METAL STUDS ® 16" 0.C. WITH 5/8" 'TYPE 'X' 'QUIETROCK' 6.11B. EACH SIDE AND SOUND BATTS IN CAVITY. 5!E 6/A6.00. HEIGHTS 6" ABOVE CEILING TO BOTTOM OF ROOF DECK 4" X 6A. METAL STUDS ® 16" 0.G. WITH 5/8" TYPE 'X' 6J1J3. EACH SIDE AND SOUND BATTS IN CAVITY. SEE 10/A6.00. 6" ABOVE GEILIN6 6. PRIOR TO COMPLETION OF CONSTRUCTION, GLEAN ALL SURFACES INCLUDING BUT NOT LIMITED TO WINDOWS (INTERIOR AND EXTERIOR), SWITCH AND OUTLET PLATES, HVAC. GRILLES AND GEILIN6 GRID. RESTORE ANY OF THE ABOVE AS REQUIRED TO LIKE -NEW AND 600D WORKING CONDITION. 1. THE CONTRACTOR SHALL ENSURE THAT THIS PROJECT AND ALL CONSTRUCTION ACTIVITIES RELATED THERETO CONFORM WITH ALL LOCAL, REGIONAL, STATE AND/ OR FEDERAL REGULATIONS PERTAINING TO DISTURBING, DISPLACING, AND/ OR REMOVAL OF ASBESTOS OR ASBESTOS CONTAINING MATERIALS. 8. PREP FLOOR FOR NEW FINISH AS REQUIRED PER FLOOR PLANS A3.0 AND FINISH PLAN FI.O. 41. PROTECT ALL AREAS OF BUILDING AND H.V.A.G. SYSTEM FROM DUST AND DEBRIS AT ALL TIMES. 10. CONTRACTOR SHALL REMOVE ALL EXISTING LOW VOLTAGE CABLING II. WHERE EXISTING EQUIPMENT, FINISHES, FIXTURES, OUTLET AND HARDWARE 15 SCHEDULED FOR DEMOLITION ADJACENT TO A WALL, GEILIN6, OR FLOOR TO REMAIN, PATCH AND REPAIR AS REQUIRED TO ACCEPT A NEW FINISH. 12. 11E PLANS SHOW GENERAL DEMOLITION WORK TO BE PERFORMED AND DO NOT RELIEVE THE CONTRACTOR FROM OTHER DEMOLITION WORK REQUIRED TO PRODUCE THE BUILDING MODIFICATIONS SHOWN ON THE REMAINING CONTRACT DOCUMENTS. 13. SOUND INSULATE ALL PLUMBING WALLS. 14. INSTALL NEW FLOORING TO EXTENT SHOWN PER FINISH PLAN ON SHEET FI.O. FLOORING AND FLOORING MAT BY TENANT. 15. REFER TO HAND 4 STONE CORPORATE SPECIFICATIONS MANUAL FOR MORE INFORMATION. 16. ALL MILLWORK/ CASEWORK MATERIAL/ INSTALL TO BE BID AS ADDITIONAL. TENANT TO PURCHASE MILLWORK IF DESIRED. REVIEWED FOR • ' E COMPLIANCE APPROVED DEC 10 2013 City of Tukwila BUILDING DIVISION 4" X 6A. METAL STUDS ® 16" 0.C. WITH 5/8" TYPE 'X' 'QUIETROCK' 6JNB. EACH SIDE AND SOUND BATTS IN CAVITY. SEE 6/A6.00. 1/2" AIRSPACE FROM EXISTING WALL, 3-5/8" X GA. METAL STUDS ® 16 " O.G. WITH 5/8" TYPE 'X' 'QUIETROCK' 6JNB. AT OUTER SIDE AND SOUND BATTS IN CAVITY. TO BOTTOM OF ROOF DECK MATCH EXISTING WALL RATIN& NON -RATED NON -RATED NON -RATED NON -RATED NON -RATED 3-5/8" X 6A. METAL STUDS 0 16" 0.G. WITH 5/8" TYPE 'X' 6.WB. EACH SIDE. 48" A.F.F. NON -RATED NOTES: I) SEE 6 4 10/A6.00 FOR 2) ALL WALLS ARE TYPE 5) SEE HAND 4 STONE FOR MORE INFORMATION. GAL WALL CONSTRUCTION. UNLESS INDICATED OTHERWISE. ORATE SPECIFICATIONS MANUAL LEGEND .......:.: NEW WALL CONSTRUCTION EXISTING WALL TO REMAIN. XX DOOR TA6 - SEE DOOR SCHEDULE SHEET A1.0 FOR DETAILS WALL TA6 - SEE WALL SCHEDULE SHEET A41.0 FOR DETAILS SINGLE DETAIL TAG - SEE SHEET LISTED IN TA6 FOR DETAIL ELEVATION TAG - SEE SHEET LISTED IN TAG FOR ELEVATION • FLOOR PLAN KEYNOTES (KN -0I) PROVIDE AND INSTALL NEW BREAK ROOM STORAGE. CONTRACTOR TO INSTALL AND SEISMICALLY BRACE TO WALL. (KN -02) LOCATION FOR TENANT'S SIGN ABOVE; VERIFY REQUIREMENTS WITH SIGN CONTRACTOR. PROVIDE POWER AS REQUIRED PER 31.0. PROVIDE AND INSTALL NEW HOT WATER HEATER PER SPECIFICATIONS MANUAL ON STRUCTURAL PLATFORM ABOVE MOP SINK. STRUCTURAL PLATFORM TO BEAft y BIDDER DESIGNED. PROVIDE ALL NECESSARY PLUMBING AND ELECTRICAL IMF (KN -04) CONNECTIONS. INSTALL TENANT -PROVIDED WASHER AND DRYER. PROVIDE DRAIN, POWER AND EXHAUST TO EXTERIOR WITH COMMERCIAL -GRADE METAL VENTING. VERIFY EXACT REQUIREMENTS WITH TENANT. TENANT -PROVIDED MICROWAVE. INSTALL IN CASEWORK PER ELEVATION AND .% PROVIDE NECESSARY ELECTRICAL CONNECTIONS. VERIFY EXACT REQUIREMENTS HIM M.Na WITH TENANT. INSTALL TENANT -PROVIDED REFRIGERATOR. PROVIDE ELECTRICAL CONNECTION 11 AS REQUIRED. PROVIDE 1/4" WATERLINE IF REQUIRED, VERIFY WITH TENANT. (KN -01) PROVIDE AND INSTALL NEW CREDENZA CASEWORK PER ELEVATIONS AND HAND 4 •_ STONE CORPORATE SPECIFICATION MANUAL. INSTALL TENANT PROVIDED RETAIL UNIT PER HAND 4 STONE CORPORATE SPECIFICATION MANUAL. SEISMICALLY BRACE AS REQUIRED. NEW RECEPTION DESK PER ELEVATIONS. L060 PROVIDED BY TENANT/ INSTALL BY U OTHERS. (KN -II) (KN -I2) (KN -14) m EXISTING ELECTRICAL PANEL TO REMAIN; VERIFY LOCATION ON SITE AND NOTIFY ARCHITECT IF ANY DISCREPANCIES. PAINT TO MATCH WALL. PROVIDE AND INSTALL SURFACE MOUNTED HAT AND GOAT RACK BEHIND DOOR PER ADA (48" A.F.F. MAX) IN EACH FACIAL AND TREATMENT ROOM PER HAND 4 STONE CORPORATE "WHAT TO BUY BOOK." PROVIDE AND INSTALL NEW FIRE EXTINGUISHER CABINET PER HAND 4 STONE CORPORATE SPECIFICATIONS MAHJAL; SEMI -RECESSED BRUSHED STAINLESS STEEL; LARSEN 24041-5R. MOUNT SO THAT TOP 15 AT 4'4" A.F.F. INSTALL NEW WATER WALL PER HAND 4 STONE CORPORATE SPECIFICATIONS AT 45" A.F.F. PROVIDE BLOCKING FOR WATER WALL AS NECESSARY. PATCH 4 REPAIR WALLS AS NECESSARY. WATER WALL PROVIDED BY TENANT. PROVIDE AND INSTALL A BOBRIGK SURFACE MOUNTED HAT AND GOAT RACK, MODEL 3-682 (BRIGHT POLISHED STAINLESS STEEL) OR 8-6821 (SATIN -FINISH STAINLESS STEEL) PER ADA (48" A.F.F. MAX) IN EACH RESTROOM. (KN -I5) FILM ON STOREFRONT/ INTERIOR DOORS BY OTHERS. INSTALL NEW RESTROOM FIXTURES AND ACCESSORIES PER 8/A6.0I. ENSURE ALL FIXTURES MEET ACCESSIBILITY REQUIREMENTS. PROVIDE ALL NECESSARY PLUMBING AND ELECTRICAL CONNECTIONS. (KN -17) PROVIDE AND INSTALL NEW MOP SINK. PROVIDE ALL NECESSARY PLUMBING AND ELECTRICAL CONNECTIONS. SIGNAGE PER HAND 4 STONE CORPORATE SPECIFICATION MANUAL. PROVIDED BY TENANT, INSTALLED BY OTHERS. PROVIDE AND 5TUBB PLUMBING FOR FUTURE USE. RECEIVED CITY OF TUKWILA , PERMIT CENTER B, 0 35 7 NOV 2 .2 2013 10401 REGISTERED MPH C PA QUIST STATE OF WASHINGTON • Y:lArchitectural Projects11313 \A13-35215 CURRENT PHASE DWGSI2 Sheets\A13-352 A3.01.dwg Nov 18, 2013 - 2:29pm kmcgough A3.01 PROJECT NUMBER: A13.35i 111 el" FREIHEIT & HO ARCHITECTS, INC., P.S. SEE STANDARD CABINETRY NOTES A6.00 SGRIBEN\, PLASTIC LAMINATE (PL -2) UPPER CABINETS ELKAY DAYTON STAINLESS STEEL DI15161 BAR SINK, 1 HOLE MODEL; MOEN MODEL 5115 SERIES FAUCET, WITH PULLOUT SPRAYER A5 PART OF FAUCET OR SEPARATE INSTALL. 2'_`° 51-0 3/4" / SCRIBE SEE STANDARD CABINETRY NOTES A6.00 5'-6 1/2" SCRIBE PLASTIC LAMINATE (PL -2) UPPER CABINETS SCRIBE PLASTIC LAMINATE (PL -I) COUNTERTOP, BAGKSPLASH 4 SIDESPLASH 3/4" PULL-OUT SHELF, 8 T ELKAY DAYTON STAINLESS STEEL DI15161 BAR SINK, I HOLE MODEL; MOEN MODEL 5115 SERIES FAUCET, WITH PULLOUT SPRAYER AS PART OF FAUCET OR SEPARATE INSTALL. 8 CARPETING AS SCHEDULED OFFSET BOXES MINIMUM OF ONE STUD SPACE (TYP) MOLDABLE PUDDY PAD AROUND JUNCTION BOX, TYP. WALL PER SCHEDULE TO STRUCTURE ABOVE LAMINATE TO MATCH TENANT -PROVIDED TOWEL CADDIE; VERIFY DIMENSIONS WITH TENANT BRUSHED CHROME CABINETRY PULLS PLASTIC LAMINATE (PL -2) LOWER CABINETS 11-6" STANDARD Z WALL SCRIBE • TOWEL CADDIE SCALE: 1/2" = I1-011 2'O" 11-6" SCRIBE SEE STANDARD CABINETRY NOTES A6.O0 r. 11 611 PLASTIC LAMINATE (PL -1) COUNTERTOP, BACKSPLASH4 SIDESPLASH PLASTIC LAMINATE (PL -I) COUNTERTOP, BACKSPLASH 4 SIDESPLASH 3/4" PULL-OUT SHELF; RESILIENT REDUCER STRIP, TO MATCH WALL BASE LAMINATE TO MATCH TENANT -PROVIDED VINYL OR EPDXY FLOOR AS SCHEDULED TOWEL CADDIE; VERIFY DIMENSIONS WITH TENANT BRUSHED CHROME CABINETRY PULLS PLASTIC LAMINATE (PL -2) LOWER CABINETS 1'-1" LARGE Z WALL SCRIBE TOWEL CADDIE NEW SOUND BATTS PER SCHEDULE FLEXIBLE CAULK AROUND ALL SIDES OF Box (TYP) .00 SCALE: 1/2" = 11-0" INSTALL #12 6A. VERTICAL WIRE AT 4'-O" O.G. CONNECTED TO MAIN RUNNER AND STRUCTURE ABOVE. INSTALL #I2 GA. WIRE GROSS BRACING, IN EACH PLANE OF MAIN RUNNER AT 12'-0" O.G. AT 45 DEGREE SHALL BE ANGLES IN' BOTH DIRECTIONS WITH THE FIRST POINT <' WITHIN 6'-0" FROM EACH WALL. INSTALL A STRUT (I-5/8" MIN.) ADEQUATE ' TO RESIST THE VERTICAL COMPONENT INDUCED BY THE BRACING WIRES. THESE •; \� I DEGREES PLACED 12 FT (3656 MM) ON CENTER IN HORIZONTAL RESTRAINT POINTS SHALL B, MAIN RUNNER ► � MAX. CR055 BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6 FT (1821 MM) FROM EACH WALL.:? NOTE: I. INSTALL A5 REQUIRED UNDER ASTM E580, ASTM 0635 AND ASTM C636. 2. SUPPORTING WIRES TO BE GAUGED AND SPACED PER ASTM 0841 TABLE 3. 3. PROVIDE LIGHT FIXTURE SUPPORT ATTACHMENT PER ASTM E580. = 21-0" 1'-q" SCRIBE VINYL TO CARPET FLOOR TRANSITION SCALE: FULL PLAN DETAIL @ OUTLET BOXES SCALE: 3" = I'-0" CEILING SPLINE BRACING �E3 LOCKS (TYP) cv 4" STAINLESS STEEL PULLS (I) ADJUSTABLE SHELF BLOCKING AS REQUIRED SCHEDULED BASE AND FLOOR 0 0 0 0 7 it DIAGONAL BRACING (MATCH WALL STUD GAUGE) ® 48" 0.G., FASTEN TO STRUCTURE ABOVE WALL CONSTRUCTION PER SCHEDULE ADJACENT CEILING. SEE CEILING `PLAN A7.00 FOR HEIGHT 4 r CONSTRUCTION. CONT. STEEL RUNNER CHANNEL, ANCHOR TO SLAB W/0.146" DIA. POWDER ACTUATED FASTENER O 36" O.G. ATTACH TO SEM HOOP OIRIGI IN •4W 0L,PASI01 "ATTACHED WALL" BERC2 MAWS GEM. S . MIN FLOM MOO FOR IeNIT COIMI TOR SCHEDULED BASE GONG EEL MNK WNI & MOOR TO PRO= OAC M P FAMINE • 34" Oa "UNATTACHED WALL" BERG2 ACOUSTICAL SEALANT ® SOUND RATED PARTITIONS ACONTE. I. MAWS • NILS MED PMHIMS 111,,1 ii4Vlli I! udh! �jlllldyq 101 dill 1,1111 1,1 RECEPTION AREA - BACK WALL CREDENZA SCALE: 1/2" = 11-0" SCHEDULED BASE AND FLOOR 11-0" -6.141B. LIGHT VALENCE, PAINT P -I. LIGHT BOX VALANCE TO BE FITTED WITH PUCK STYLE LED DOWN LIGHTS ABOVE GLASS SHELVING. --COUNTERTOP - 4" STAINLESS STEEL PULLS (I) ADJUSTABLE SHELF BLOCKING AS t• REQUIRED I'-7" 4 211 RETAIL AREA A6.00 SCALE: 1/2" =ILO" I'-0" DLR. i n 4 �v 21-1" 412 ADJUSTABLE SHELVES, TYPICAL 4" STAINLESS STEEL PULLS COUNTERTOP AND BAGKSPLASH DRAWERS; PROVIDE SHOP DRAWINGS TO ARCHITECT TO VERIFY LOCATIONS (I) ADJUSTABLE SHELF BLOCKING AS REQUIRED SCHEDULED BASE AND FLOOR r2N 21-0" BREAKROOM KITCHEN CABINETS SCALE: 1/2" = I:-011 SCHEDULED FLOORING TYP. INTERIOR WALL CONSTRUCTION TYP. FULL HEIGHT WALL CONSTRUCTION 2 A6.00 GLASS SHELF BRACKETS WITH FRONT STOPS, CENTER RESTS AND RUBBER CUSHIONS HEAVY DUTY RECESSED - STANDARDS AND BRACKETS WITH 2" VERTICAL ADJUSTMENT 3/4" THICK WALL PANELS WITH PLASTIC LAMINATE (PL -3) (7) 1/4" GLASS SHELVES Of 1/8" X 34") PLASTIC LAMINATE (PL -I) COUNTERTOP, BACKSPLASH SIDESPLASH LOCK, TYP. BRUSHED CHROME CABINETRY PULLS PLASTIC LAMINATE (PL -2) LOWER CABINETS SEE STANDARD CABINETRY NOTES A6.00 in 4 404" 410, 0 LatliELIPADDEll Milik.,4 m 21-2" L 2'-2" 21-2" 21-2" L , • n 21" 21-3" 1'-5" CABINET DOLOR: MAPLE MELAMINE ELECTRIC RECHARGE STATION DAYTON DI17213 17"X21" STAINLESS STEEL SINK, 3 HOLE MODEL 4122856; KOHLER STAINLESS STEEL SINGLE LEVER FAUCET WITH STRAINER * SIDE SPRAY. ENSURE ADA COMPLIANT. PLASTIC LAMINATE (PL -1) COUNTERTOP, BAGKSPLASH # SIDESPLASH BRUSHED CHROME - CABINETRY PULLS VERIFY If3/4" END PANEL CABINET COLOR: MAPLE MELAMINE P1PRPP 2'-6" 1 2'-3" 11-2" SEE STANDARD CABINETRY NOTES A6.00 COMPOSITE DESIGN FOR NON-STRUCTURAL STEEL PARTITIONS SCRIBE PLASTIC LAMINATE (PL -2) UPPER CABINETS 30 MILS STUDS o 5 PSF (25 GA NOMINAL) STUD SIZE 33 MILS STUDS 0 5 PSF (20 6A NOMINAL) STUD LIMITING WALL SPACING HEIGHT STUD SIZE STUD LIMITING WALL SPAGIN6 HEIGHT BERC CLIP -GRID DETAIL SCALE: NOT TO SCALE 10 6A: HANGER WIRES AT 4'-0" ON CENTER MAXIMUM EACH WAY (TYPICAL) CONTINUOUS ANGLE AT WALL EDGE TYPICAL 6" MAX. PLASTID LAMINATE (PL -I) COUNTERTOP, BACK -SPLASH 4 SIDESPLASH 3/4" PULL-OUT SHELF; LAMINATE TO MATCH TENANT -PROVIDED TOWEL CADDIE; VERIFY DIMENSIONS WITH TENANT BRUSHED CHROME CABINETRY PULLS PLASTIC LAMINATE (PL -2) LOWER CABINETS SCRIBE MODIFIED Z WALL PIPP1P \ALA ly LatliELIPADDEll Milik.,4 m 11_y0 11 A6Oo SCALE: 1/2" = 11-0" 11-6" 't SCRIBE THE LAMINATE BOND TO THE SUBSTRATE SHALL BE ACCOMPLISHED WITH A WATER-RESISTANT ADHESIVE. CABINETS TO BE CONSTRUCTED OF 3/4" MDF. UNLESS OTHERWISE NOTED, EXTERIORS ARE TO BE PLASTIC LAMINATE GLAD. ALL SHELVING TO BE 3/4" MDF WITH PVC NOSIN& AND MELAMINE SURFACES (WHITE) TOP/BOTTOM, BACK. SHELF TO BE SUPPORTED BY HEAVY DUTY ADJUSTABLE SYSTEM I" INCREMENTS). MAXIMUM SHELF LENGTH TO BE 3'-0". 3. VERIFY ALL DIMENSIONS ON SITE. 4. PROVIDE BLOCKING AT ALL WALLS SUPPORTING WALL CABINETRY, BASE CABINETRY OR SHELVING. 5. TYPE OF CONSTRUCTION TO BE FLUSH OVERLAY UNLESS OTHERWISE NOTED. 6. ALL CABINETRY ENDS SHALL BE SCRIBED TO WALLS. 7. HARDWARE: HINGES: EUROPEAN FULLY CONGEALED TYPE, SELF-CLOSING', HEAVY-DUTY. DRAWER SLIDES: ROLLER BEARING EPDXY COATED STEEL SLIDES, BOTTOM -MOUNTED. PROVIDE FULL EXTENSION SLIDES ON ALL DRAVERS. PULLS: 4" WIRE PULLS WITH BRUSHED STAINLESS FINISH. 8. REFER TO FINISH PLAN (FI.0) FOR PLASTIC LAMINATE FINISH. 12 ALL SURFACES AND EDGES EXPOSED TO VIEW SHALL RECEIVE PLASTIC LAMINATE FINISH UNLESS OTHERWISE NOTED. INTERIORS ARE TO BE MELAMINE CLAD (WHITE). STANDARD CABINETRY NOTES A6.00 SCALE: NTS. 1625125 (I-5/6") 2505125 (2-1/2") 3505125 (3-5/8") 4005125 (4") 6005125 (6") 12" 16" 24" 12" 16" 24" 12" 16" 24" 12" 16" q'-11" 1'-2" '3" 1625125 (I-5/8") 13'-2" 12'-1" 101-1" 17'-I" I5'-8" I4'-0" 1'-8" 8'-1" 2505125 (2-1/2") 12'-10" 3625125 (3-5/8") 17' -IO" 14'-q" 4005125 (4") 181-4" 24" 12" 16" 24" 25'-6" 23'-2" 20'-3" 6005125 (6") 24" 26'-1" 211-7" Y,1Architectural Projects11313W13-35215 CURRENT PHASE DWGS12 Sheets1A13-352 A6.00.dwg Nov 18, 2013 - 2:30pm kmcgough 1 1 1 NOTES: • ASSUMED ALLOWABLE DEFLECTION = L/240 • PROVIDE STUD BRIDGING AS REQUIRED BY 60VERNING CODES AND REGULATIONS BASED ON 55MA I0130 ER -4145P AND INDUSTRY TECHNICAL NOTE 4, NOV. 2001 10. ALL CABINETS TO BE CONSTRUCTED PER ANI MANUAL, 7TH EDITION, TO CUSTOM &RADE SPECIFICATIONS. 11. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO FABRICATION. 12. ALL CABINETS TO HAVE BRUSHED CHROME PULLS. 13. ALL CABINETS INTERIOR COLOR WHITE MELAMINE. 14. ALL CABINET EXTERIORS FULLY LAMINATED WITH PREMIUM WILSONART LAMINATE, 7156K-01 WILLIAMSBUR6 CHERRY. 15. ALL CABINETS FRAMELESS 52MM CASEWORK WITH LINE BORED FOR ADJUSTABLE SHELVES. 16. ALL CABINETS BLUM CLIP ON HINGES, THREE DIMENSIONAL INDEPENDENT ADJUSTMENTS 17. BLUM DRAWER SLIDES AT ALL 6" DRAWERS. I8. FULL EXTENSION KV DRAWER SLIDES AT ALL LARGER FILE DRAWERS. I. ALL BASE CABINET COUNTER TOPS: MYSTIC GEMSTONE 1850K-55. 20. ALL CABINETS 5/4" THICK MELAMINE CONSTRUCTION, WALL CABINETS PATIO 1/2" FULL BACK PANELS. ,10010•0/- O \••00.1141,410•••••00.1100cAV 0°1- 10 &A WIRE HANGERS AT PERIMETER SUPPORTING MAIN RUNNERS AND GROSS RUNNERS 8" MAX FROM EDGE. RECESSED LIGHT FIXTURE WHERE OCCURS 10 6A LATERAL BRACING WIRES 2'-0" MAXIMUM FROM CHANNEL INTERSECTION AT APPROXIMATELY 45° IN EACH DIRECTION. LOCATED ON A 8'-0" X 12'-0" O.G. GRID AND A MAX. 6'-O" FROM WALLS. MAIN RUNNERS: 1 1/2" GOLD ROLLED CHANNELS AT 4'-0" ON CENTER MAXIMUM 7/8" X 22 &A &ALV. HAT FURRING CHANNEL AT 2'-0" O.G. MAX. 5/8" TYPE 'X' GINS G.W.B. CEILING GRID SUPPORT SCALE: NOT TO SCALE b13o 3 REVIEVVED FOR DE COMPLIANCE APPROVED DEC 10 2013 City of Tukwila (AGOING DIVISION RECEIVED CITY OF TUKWILA NOV 2 2 2013 PERMIT CENTER NOT USED SCALE: NTS. y,. Wyk 12 s'l is U. ` REGISTERED ARCH SEPH C PALMQUIST STATE OF WASHINGTON A6.00 PROJECT NUMBER: A13.352 11118113 0 FREIHEIT & HO ARCHITECTS, INC., P.S. I'-0" ADJUSTABLE SHELVES, TYPICAL I'-8" • • • • 4" STAINLESS STEEL PULLS COUNTERTOP AND BAGKSPLASH (I) ADJUSTABLE SHELF BLOCKING A5 REQUIRED SCHEDULED BASE AND p,:—ti: FLOOR f ilk LARGE & SMALL Z WALL SECTION, TYP. SCALE: 1/2" = I' -O" GUT CIRCULAR OPENING TOWARDS BACK FOR CORDS. PLASTIC LAMINATE (PL -I) COUNTERTOP CABINET COLOR: MAPLE MELAMINE PLAN 4'-0" 9 ELEVATION r"")BREAK ROOM - LARGE CPU SHELF �A6.SCALE: 1/2" : I'-0" 14 0 TAMPON DISPENSER v- « 4 URINAL z PAPER TOWEL S.M. SOAP SURFACE DISPENSER/ DISPENSER MOUNTED PAPER WASTE CONTAINER TOWEL DISPENSER 54" MIN. 341" MIN. 41" MAX. 12" MAX.'—/N ,r42" MIN. i=F 0 c — z f T- o q" 'MAX. FROM SEAT TO GRAB BAR WATER CLOSET 4 �` GRAB BARS SIDE VIEW SURFACE MOUNTED HAND DRYER E 0 MIRROR TOILET PAPER HOLDER W/0 STOPS PLACEMENT SHALL X NOT PREVENT USE • OF GRAB BAR GEN. MOUNTING HEIGHTS A6.0I SCALE: N.T.S. X zz 48" CLEAR MIN. PATH OF TRAVEL 1- FROM FACE OF ACCESSORY 4" MAX PROTRUSION FOR ACCESSORIES HIGHER THAN 21" C�-- ACCESSORY 56" MIN. 24" FOLD DOWN BABY CHANGING STATION 6" MAX. 12" MIN. FLOOR -MOUNTED WATER CLOSET 4 GRAB BARS FRONT VIEW TOILET ACCESSORY MOUNTING DETAIL INSULATE HOT WATER DRAIN PIPES =I - N XN WALL MOUNTED/ COUNTER MOUNTED LAVATORY Z 1 in SURFACE MOUNTED TOILET PAPER DISPENSER 1 SURFACE MOUNTED SHELF e o s f S.M. TOILET SWITCHES SEAT COVER DISPENSER MOP AND BROOM COAT HOOK BRACKET FIRE HOLDER EXTINGUISHER RECEPTACLE THERMOSTAT L7 1 DRINKING FOUNTAIN VEY LOGO EP -OUT — 5'-4 1/2" VERHAN6 ON NITE TOP AMINATED WALL L_J O 7 5:511 f 51-O" 111-0" L 211.0 11 ,8 FRONT DESK ENLARGED PLAN A6.0� SCALE: 1/2" = ILO" I-1/8" P -LAM ADJUSTABLE SHELF ON 2" O.G. SHELF CLIPS 1-1/8" P -LAM GLAD PLYWOOD AT ALL CABINET INTERIORS, TYPICAL I8" BRUSHED CHROME CABINETRY PULLS CABINET COLOR: MAPLE MELAMINE BASE PER SCHEDULE 14 ADJUSTABLE OPEN SHELVES PER SECTION (PL -I) LI L 2'-6" Jr 2-6" BREAK ROOM - STORAGE A6.OI SCALE: 1/2" = I' -O n 0 I' -O" GLR. / ADJUSTABLE SHELVES, TYPICAL I'-8" 4" STAINLESS STEEL PULLS COUNTERTOP AND BACKSPLASH SLIDEOUT SHELF AREA FOR TOWEL CADDIE (I) ADJUSTABLE SHELF BLOCKING AS REQUIRED SCHEDULED BASE AND FLOOR r to LARGE & SMALL Z WALL SECTION, TYP. SCALE: 1/2" = I' -O" A6.01 NOT USED .01 SCALE: 1/2" : I' -O" NON GLARE SURFACE PICTOGRAM TO APPEAR ON MINIMUM 6" HIGH CLEAR FIELD, COLOR CONTRAST WITH BACKGROUND TACTILE CHARACTERS (RESTROOM), 5/8" MINIMUM GAP HEIGHT, RAISED 1/32" MINIMUM, FULL CAPS, SANS SERIF, COLOR CONTRAST WITH BACKGROUND GRADE 2 BRAILLE PROVIDE SIGN WITH A WHITE INTERNATIONAL SYMBOL OF ACCESSIBILITY (I.SA) ON A BLACK BACKGROUND, MOUNT ON THE TOILET ROOM ENTRANCE DOOR WALL ON THE LATCH SIDE OF THE DOOR. *"NOTE: SEE DETAIL 16/A6.0 FOR ADDITIONAL SIGNAGE REQUIREMENTS RESTROOM SIGN q" MIN z f _A6.OI SCALE: 1/2" = I' -O" CL • GRANITE TRANSACTION or4, I'-2' TOP BY OWNER (Q -I) FRONT DESK SECTION PLASTIC LAMINATE (PL -I) COUNTERTOP BLACK PLASTIC LAMINATE 2" STONE FADE APPLIED IN FIELD (0-2) PRINTER SLIDE -OUT BLOCKING AS REQUIRED SCHEDULED BASE AND FLOOR A6.0I SCALE: 1/2" = I'-0" 15 0-1 GRANITE TRANSACTION TOP SELECTED BY OWNER 0-2 CULTURED STONE - PRO -FIT ALPINE LED&ESTONE - BLACK LAMINATE APPLIED TO WALL a¶ u, 15" X 2" MOUNTING DISK FOR STONEY LOGO EQ. 5L0" EQ. FRONT DESK FRONT ELEVATION A6.0I SCALE: 1/2" = I' -O" / MEN'S RESTROOM I (EXISTING) 106 1 ENLARGED PLAN KEY 0 NEW SURFACE -MOUNTED PAPER TOWEL DISPENSER AND WASTE RECEPTACLE, MOUNT 40" A.F.F. MAX. TO ACCESS POINT. BOBRIGK, B-34041, OR APPROVED EQUAL IF NEW PROVIDED. 2 NEW TOILET PAPER DISPENSER, MOUNT ®15" A.F.F. TO ACCESS POINT. BOBRIGK, 5-6651 SATIN FINISH STAINLESS STEL RECESSED WITH STORAGE SPACE FOR EXTRA ROLL OR APPROVED EQUAL IF NEW PROVIDED. ONEW 11/2 DIA. STAINLESS STEEL GRAB BAR, MOUNT ® 55-56" A.F.F. TO TOP OF GRIPPING SURFACE. ® NEW ADA -COMPLIANT TOILET. KOHLER, K-5611 OR K-4151 OR APPROVED EQUAL IF NEW PROVIDED. fa • 0,1,41 • 0 NEW SURFACE -MOUNTED NAPKIN DISPOSAL, MOUNT ® 15" A.F.F. TO ACCESS POINT.rr. BOBRICK, 13-210 OR APPROVED EQUAL IF NEW PROVIDED. O NEW LAVATORY, WHITE WITH ADA COMPLIANT POLISHED CHROME FAUCET. KOHLER SINK,�_ K -112q OR APPROVED EQUAL IF NEW PROVIDED. KOHLER FAUCET, K-8438 OR APPROVE'` EQUAL IF NEW PROVIDED. ® NEW INSTALL GENDER SIGN AND INTERNATIONAL SYMBOL OF ACCESS SIGN AS REQUIRED BY WAG 51-40 1103.2.4. 111111 ®NEW I I/2" DIA. STAINLESS STEEL GRAB BAR, 18" MIN. LENGTH MOUNTED Sq" -41" TO BOTTOM OF GRAB BAR. Og NEW STAINLESS STEEL ANGLE FRAMED MIRROR. BOBRIGK B -2g0 3656 OR APPROVED EQUAL IF NEW PROVIDED. 0 20 I'-2° Q -I, GRANITE I� IC, TRANSACTION TOP BY 4i- .4 OWNER NARKS • • FRONT DESK SECTION PLASTIC LAMINATE (PL -I) COUNTERTOP (2) ADJUSTABLE SHELVES BLOCKING AS REQUIRED SCHEDULED BASE AND FLOOR A6.01 SCALE: 1/2" = I' -O" 16 WALL AT RECEPTION 5/4" PLYWOOD SUBSTRATE STUDDED OUT. INTERNAL CUTOUTS FOR WIRE MANAGEMENT. PLYWOOD ON BOTH SIDES OF WALL, INTERIOR WALL HAS REMOVABLE ACCESS PANELS. EXTERIOR AND INTERIOR OF WALL ARE FULLY LAMINATED WITH WILSONART LAMINATE,1g36K-0'1. ALSO SEE STANDARD CABINETRY NOTES A6.00. GRANITE TRANSACTION TOP BY OWNER PLASTIC LAMINATE (PL -I) COUNTERTOP 4"x18" PENCIL DRAWER. PLASTIC LAMINATE (PL -2), TYPICAL OF 2 BRUSHED CHROME CABINETRY PULLS KEYBOARD SPACE TO ACCOMMODATE GASH DRAWERS SIZE 18 I/811 X 18"D X 4 I/2"H. PRINTER SLIDEOUT FRONT DESK - BACK ELEVATION A6.0I ALE: 1/2" = I' -O" TWO SHELVES WOMEN' RESTROOM (NEW) 105 RESTROOM DETAIL PLAN A6.0I SCALE: 1/2" = I'-0" RESTROOM NOTES I. INSULATE EXPOSED HOT 4 COLD WATER AND DRAIN PIPES WITH MOLDED BLACK VINYL COVERING. 2. WATER RESISTANT G.N.B. TO BE USED ON ALL RESTROOM WALLS. 3. FAUCETS TO BE LEVER ACTION TYPE WITH LEVER WITHIN 11" OF SINK FADE. 4. PROVIDE EXHAUST FAN CAPABLE OF EXHAUSTING 6 AIR CHANGES PER HOUR WITH 1/4" STATIC PRESSURE. FAN SHALL BE POWERED BY BACK-UP ELECTRICAL SYSTEM. 5. PROVIDE BLOCKING AS REQUIRED FOR ALL RESTROOM ACCESSORIES AND FIXTURES. 6. SOUND INSULATE ALL PLUMBING LINES ABOVE SLAB. 1. ALL DIMENSIONS ARE FROM FINISH FADE UNLESS NOTED OTHERWISE. 8. ALL RESTROOMS TO MEET ALL WASHINGTON STATE REGULATIONS FOR BARRIER FREE FACILITIES, WAG 51-50. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 10 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 2 2 2013 PERMIT CENTER yS Y:\Architectural Projects113131A13-35215 CURRENT PHASE DWGS12 Sheets1A13-352 A6.01.dwg Nov 18, 2013 - 2:31 pm kmcgough Aft LYN AT SOUTHCENTER S 10401 REGISTE D ARC • SEPH C PALMQUIST STATE OF WASHINGTON • CHECK SET PHUT A6.01 PROJECT NUMBER: A13.352 11118113 0 FREIHEIT & HO ARCHITECTS, INC., P.S. 1 . Cd .J. ACT.F®+q'-6" $V®+q'-0" 0 �T.F+'-6" A.. A.F.F. 04-0" .F. l\--(CN-03� V REFLECTED CEILING PLAN SCALE: 1/4" = I'-0" CEILING KEYNOTES CEILING NOTES (CN -01) (GN -o2) VOLUME SWITCH TO CONTROL VOLUME IN BATHROOM 4 HALLWAYS. VOLUME SWITCH TO CONTROL VOLUME IN LOBBY. (GN -03) UNPAGED SOUND INSULATION ABOVE CEILING TILE TO BE BID AS ADDITION. I. INSTALL ACOUSTICAL TILE AS SCHEDULED. PROVIDE SEISMIC GEILIN6 BRACING PER DETAIL I/A6.00 4 2/A6.00 A5 REQUIRED. 2. ALL NEW SWITCHES SHALL BE AT +48" A.F.F. UNLESS NOTED OTHERWISE. 5. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. 4. ALL CEILING TILE AND GRID 15 TO BE NEW AS SPECIFIED UNLESS NOTED OTHERWISE. ALL GRID AND TILE TO BE CENTERED IN ROOM U.N.O. MANUFACTURER: USG STYLE: RADAR ILLUSION, LOOK OF 24" X 24" PANELS; CLASS A, ITEM #2742 COLOR: WHITE EDGE: SHADOWLINE TAPERED 5. CONTRACTOR TO SUPPLY JUNCTION BOXES W/ PULLGORDS FOR SPEAKERS AND VOLUME CONTROL FOR TENANT'S MUSIC PROVIDER. COORDINATE EXACT REQUIREMENTS WITH TENANT'S MUSIC PROVIDER. SPEAKERS SHOWN FOR INFORMATION ONLY. 6. SPRINKLER SYSTEM UNDER SEPARATE PERMIT. 7. SEE HAND 4 STONE CORPORATE SPECIFICATIONS MANUAL FOR MORE INFORMATION. 8. NOT USED. q. PROVIDE DUCTED RETURN HVAC SYSTEM THROUGHOUT. 10. DESIGN/BUILD HVAC SYSTEM SHALL INCORPORATE A MINIMUM OF (I) DIFFUSER AND (I) RETURN AIR GRILLE IN EACH ROOM. PROVIDE SHOP DRAWINGS TO TENANT FOR APPROVAL. 10.1 RETURN TO BE LOCATED ABOVE COUNTER AREA IN TREATMENT ROOMS. II. RELOCATE SPRINKLERS A5 REQUIRED BY NEW CEILING; SPRINKLER SYSTEM TO BE BIDDER -DESIGNED AND UNDER A SEPARATE PERMIT. LEGEND NEW 6" CAN LIGHT WITH WHITE TRIM AND DIMMABLE LED MODULE; I41N HALO-H7T TOP LED 14DR5627K. NEW THOMAS #5L770363 3 LT. ROCKFORD BATH LIGHT BRONZE FINISH AT 80" A.F.F.; SL #58034 IOW AIq LED LAMP. NEW PROGRESS #P718I-77 TORINO WALL SCONCE AT 80" A.F.F.; SL #5(1034 IOW AK! LED LAMP. NEW LANDMARK #00I -AB AURORA SCONCE - ANT. BRZ AMBER SGAVO &LASS AT 80" A.F.F.; SL #58034 I01N AIq LED LAMP. O NEW 6" COMPACT FLUORESCENT WALL WASHER SINGLE POLE SWITCH, LETTER DENOTES SWITCHING 40 DIMMER SWITCH; LUTRON GT -600P -WH; 600161 SKYLARK DIMMER SINGLE POLE LUTRON GT -603P -WH; 6001,1 SKYLARK DIMMER 3 WAY 5WITCH EXIT EXISTING/ RELOCATED ILLUMINATED EXIT SIGN SPEAKER FOR TENANT'S SOUND SYSTEM VOLUME CONTROL NEW 6.WB. GEILIN6 HEIGHT PER PLAN NEW CEILING TILE 4 GRID RADAR ILLUSION TWO/24 PANELS GLASS A, ITEM #2742 WHITE CEILING, GRID WHITE EDGE: SHADOWLINE TAPERED HEIGHT PER PLAN NREC LIGHTING G TING B D U GET TABLE NREC EC NOTES QTY LIGHT WATTS/FIXTURE WATTS 35 6" FLUORESCENT CAN LIGHT, 141N LED LAMP 14 440 2 2 x 4 SUSPENDED DIRECT/INDIRECT FLUORESCENT FIXTURE. (2) 32A FL LAMP. 64 128 2 RECESSED WALL WASHERS, 1411 LED LAMP 14 28 2 5 -LT BATHROOM SCONCES, (5) IOW LED LAMP 30 60 14 TORINO WALL SCONCES, IOW LED LAMP 10 140 8 AURORA WALL SCONCES, IOW LED LAMP I0 80 SUBTOTAL q26 +I0% ESTIMATE FOR BALLASTS. q3 TOTAL PROPOSED DESIGN LIGHTING WATTAGE. I,OIq W BUILDING AREA 2,664 SF UNIT LIGHTING, POWER ALLOWANCE (PER 2006 WSEC TABLE 15-1) OA A/5F TOTAL LIGHTING POWER ALLOWANCE 2,588 WATTS C405.2.2.5 DAYLIGHT ZONE CONTROL DAYLIGHT ZONES SHALL BE DESIGNED SUCH THAT LIGHTS IN THE DAYLIGHT ZONE ARE CONTROLLED INDEPENDENTLY OF GENERAL AREA LIGHTING AND ARE CONTROLLED IN ACCORDANCE WITH SECTION 0405.2.2.32. EACH DAYLIGHT CONTROL ZONE SHALL NOT EXCEED 2,500 SQUARE FEET. CONTIGUOUS DAYLIGHT ZONES ADJACENT OT VERTICAL FENESTRATION ARE ALLOWED TO BE CONTROLLED BY A SINGLE CONTROLLING DEVICE PROVIDED THAT THEY DO NOT INCLUDE ZONES FACING MORE THAN TWO ADJACENT CARDINAL ORIENTATIONS (I.E., NORTH, EAST, SOUTH, WEST). THE PRIMARY DAYLIGHT ZONE SHALL BE CONTROLLED SEPARATELY FROM THE SECONDARY DAYLIGHT ZONE. CONTROLS SHALL: I. CONTROL ONLY LUMINAIRES WITHIN THE DAYLIT AREA. 2. INCORPORATE TIME -DELAY CIRCUITS TO PREVENT CYCLING OF LIGHT LEVEL CHANGES OF LESS THAN THREE MINUTES. EXCEPTION: DAYLIGHT ZONES ENCLOSED BY WALLS OR GEILIN6 HEIGHT PARTITIONS AND CONTAINING TWO OR FEWER LIGHT FIXTURES ARE NOT REQUIRED TO HAVE A SEPARATE SWITCH FOR GENERAL AREA LIGHTING. 040522.52 AUTOMATIC DAYLIGHTING CONTROLS 5ETPOINT AND OTHER CONTROLS FOR CALIBRATING THE LIGHTING CONTROL DEVICE SHALL BE READILY ACCESSIBLE. DAYLI6HTING CONTROLS DEVICE SHALL BE CAPABLE OF AUTOMATICALLY REDUCING THE LIGHTING POWER IN RESPONSE TO AVAILABLE DAYLIGHT BY EITHER ONE OF THE FOLLOWING METHODS: I. CONTINUOUS DIMMING USING DIMMING BALLASTS AND AYLIGHT-SENSING AUTOMATIC CONTROLS THAT ARE CAPABLE OF REDUCING THE POWER OF GENERAL LIGHTING IN THE DAYLIT ZONE GONTINJOUSLY TO LESS THAN 20 PERCENT OF RATED POWER AT MAXIMUM LIGHT OUTPUT. 2. STEPPED DIMMING USING, MULTI-LEVEL SWITCHING AND DAYLIGHT -SENSING CONTROLS THAT ARE CAPABLE OF REDUCING LIGHTING POWER AUTOMATICALLY. THE SYSTEM SHALL PROVIDE A MINIMUM OF TWO CONTROL CHANNELS PER ZONE AND BE INSTALLED IN A MANNER SUCH NAT AT LEAST ONE CONTROL STEP IS BETWEEN 50 PERCENT AND 70 PERCENT OF DE5I6N LIGHTING POWER AND ANOTHER CONTROL STEP 15 NO GREATER THAN 35 PERCENT OF DESIGN POWER, AND THE SYSTEM 15 CAPABLE OF AUTOMATICALLY TURNING THE SYSTEM. OFF. 1j 13- 0357 7 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 10 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 2 2 2013 PERMIT CENTER a�Y 0 a 0.' = 0 , oho U • "1 -.= NMI al 1111 116 Y:IArchitectural Projects113131A13-35215 CURRENT PHASE DWGS12 Sheets1A13-352 A7.00.dwg Nov 18, 2013 - 2:32pm kmcgough 1 1 W H Z W 0 1 FIN 0 1 a 10401 J • SEPH C PAkIGIQUIST STATE OF WASHINGTON A7.00 PROJECT NUMBER: A13.35'/1118113 0 FREIHEIT & HO ARCHITECTS, INC., P.B. Y:1Architectural Projects113131A13-35215 CURRENT PHASE DWGS12 Sheets1A13-352 A9.00.dwg Nov 18, 2013 - 2:34pm kmcgough fry '„ 40 10401 AT SOUTHCENTER S REGISTERED AR HIT • SEPH C PAL '" IST STATE OF WASHINGTON A9.00 PROJECT NUMBER: A13.351118113 0 FREIHEIT & HO ARCHITECTS, INC., P.S. DOOR SCHEDULE GENERAL DOOR NOTES DOOR HARDWARE SCHEDULE TYPE SIZE CLASS CONST. HARDWARE SET RATING REMARKS I. WHERE REQUIRED, GLAZING IN DOOR SHALL MEET THE SAFETY GLAZING REQUIREMENTS OF IBC 2406. 2. DOORS TO BE REUSED SHALL BE REPAIRED PRIOR TO PAINTING TO A LIKE -NEW APPEARANCE. 5. DOOR FRAMES TO BE TIMELY INDUSTRIES COLD ROLLED STEEL '5' SERIES, 25 GAUGE, ALUMATONE 5GIOS. FRAME CASINGS TO BE STEEL WITH CORNER ALIGNMENT CLIPS; MODEL TA -5 WITH 6 MM REVEAL. FIT FACTORY ASSEMBLED UNITS WITH MITER6ARD CORNER ALIGNMENT CLIPS. SEE HAND 4 STONE CORPORATE SPECIFICATIONS FOR MORE INFORMATION. ALL NEW WOOD DOORS TO COMPLY WITH THE FOLLOWING: TYPE: WOOD SOLID GORE STYLE: SLAB DOOR THICKNESS: 1-5/4" THICK STAIN: MINWA X WOOD FI141514 SATIN - EN6LISH CHESTNUT 41233 COLOR: PAINT SELECTED BY OWNER 5. ALL WOOD WORK FINISHED ON SITE (STAINED, SEALED AND CLEAR FINISHES APPLIED) BE INSPECTED AND APPROVED BY THE TENANT. 6. ALL DOOR HARDWARE TO BE SATIN CHROMIUM FINISH OR BRUSHED STAINLESS FINISH. 1. REFER TO NAND 4 STONE CORPORATE SPECIFICATION MANUAL FOR MORE S. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES 014 DOORS REQUIRED TO BE ACCESSIBLE BY CHAPTER II SHALL NOT REQUIRE TIGHT &RASPING, TI6HT PINCHING OR TWISTING OF THE WRIST TO OPERATE. H5 -I 11/2 SET BUTT HIN&E5 I LEVER PASSAGE SET (SGHLAGE ALIOS JUPITER) I SET SILENCERS H5-2 I 1/2 SET BUTT HINGES I LEVER PASSAGE SET (SGHLA6E ALIOS JUPITER) I SET SILENCERS I CLOSER (LGN 404 SERIES) I DOOR STOP (WALL MOUNTED) H5-5 11/2 SET BUTT HINGES LEVER LOGKSET (OFFICE FUNCTION, SGHLA&E AL r��) I SET SILENCERS H5-4 1 1/2 SET BUTT HINGES I STAINLESS STEEL PUSH PLATE (IVES 5200) I PULL HANDLE (IVES 5105-0; 10" CENTER -TO -CENTER) I SET SILENCERS I CLOSER (LGN 404 SERIES) 1 DOOR STOP (CLOSER MOUNTED) H5-5 I 1/2 SET BUTT HINGES I CLOSER (LGN 404 SERIES) I STAINLESS STEEL PUSH/PULL TRIM (IVES 5200) I THUMBTURN (ADA COMPLIANT) DEADBOLT OR OCCUPANCY INDICATOR 1 SET SILENCERS I DOOR STOP (CLOSER MOUNTED) 145-6 I STAINLESS STEEL RECESSED PULL HANDLE I HEAVY DUTY BYPASS KIT 4 WIRE PULLS H5-7 11/2 SET BUTT HINGES I LEVER LOGKSET (STORAGE FUNCTION, SGHLA6E AL80PD) I SET SILENCERS SEE SPECIFICATION MANUAL FOR MORE DETAILED HARDWARE REQUIREMENTS. a L3 x § ; g, 9 N X 0 IOOA A EX EX EX EX EX EX. FN -01, FN -02, FN -05 1005 5 3'-0" 7'-0" 1 9/4" * WOOD 5Th. H5-4 * FN -04, FN -0'1 IOIA G 3'-0" 71-0" 1 9/4' * WOOD STL. 145-1 • IO2A G 3'-O" 7'-O" 1 9/4' * WOOD STL. 145-1 * 105A G 3'-0" 7'-0" 1 9/4' • WOOD 311-. 145-I •I I04A G 5'-0" 7' O' 1 9/4' • WOOD STL. 145-1 •4. 105A G 3" '-0 T-0" 19/4' • WOOD 511. H5-5 # 106A G 3'-0" 7'-0" 1 9/4' • WOOD STL. 145-5 * 101A G 3'-0" 7'-0" 1 9/4' • WOOD 5Th. H5-4 1015 D EX. EX. EX. EX. EX. EX. FN -01, FN -02, FN -05, FN -07, FN -0S IOSA E 4'-0" 7'-0" I 9/4' • WOOD 5T1.. 1-5-6 * 10 A G 3'-0" 7'-O" 1 s/4' • WOOD 5TL. 145-7 •SHALL IIOA E 5'-O" 7'-0" 1 9/4' • WOOD STL. 145-6 • IIIA E 5'-0" 7'-0" 1 9/4' • WOOD STL. 145-6 fil I12A G 3'-0" T-0" 19/4. • WOOD STL. 145-1 * 1125 G 3'-0" 7-0" I s/4" 41 WOOD STL. 145-I *INFORMATION. 113A G 3'-0" 7'-O" 1 9/4' * WOOD STL. 145-1 # II4A C 3'-0" 7'-0" 1 9/4" * WOOD STL. 145-1 * II5A G 3'-0" 7'-0" 1 9/4' • WOOD 511. 145-1 * II6A 5 5'-0" 7'-0" 1 s/4" * WOOD STL. 115-3 • FN -04 IIIA G 5'-O" 7'-O" 1 S/4' * WOOD STN. HS -I • IISA G 3'-0"7'-0" '" 1 s/4' * WOOD 51L. 145-1 • FN -0I REPAIR DOOR, FRAME, AND HARDWARE TO LIKE -NEW CONDITION, REKEY A5 REQUIRED. FN -02 AT EXISTING EXTERIOR DOORS PROVIDE NEW WEATHERSTRIPPING, 6ASKETING AND THRESHOLDS AS REQUIRED. FN -05 TENANT -PROVIDED HAND 4 STONE L0&0 AND BUSINESS HOURS 014 &LASS IN DOOR. FN -04 FROSTED GLASS TO BE INSTALLED BY OTHERS IN RE -LITE WITH HAND 4 STONE L060 AT EYE LEVEL AND TRANSPARENT. VERIFY WITH TENANT PRIOR TO ORDERIN6 DOOR. FN -05 PAINT SELECTED BY OWNER 4 ACCEPTABLE TO LANDLORD. FN -06 VERIFY EXISTING DOOR MATCHES HAND 4 STONE CORPORATE STANDARDS. PROVIDE NEW IF NECESSARY. FN -07 HAND 4 STONE LETTERING/ UNIT # TO BE INSTALLED ON EXTERIOR BY TENANT. FN -08 DOOR VIEWER ("PEEP HOLE") INSTALLED BY 6.G. IF NOT EXISTING. DOOR TYPES 1 1 1 1 1 SEE SEE SCHEDULE SGHEDULET SEE SCHEDULE 5E SGHEDULE,r SEE SCHEDULE ie ie DOOR 1 \I I I I I l l VIEWER(S)y WHERE NOTED 9 9 \� \\ 9 ,- ) - 1 I Q= V o o FIN. — FIN. — / FIN. — FIN. — / FIN. \ FLOOR„ FLOOR I 1 I 1 1 1 , \ FLOOR \„ ` FLOOR `„ FLOOR `„ a0 0 CO 0 0 o BUILDING STANDARD BUILDING STANDARD BUILDING STANDARD BUILDING STANDARD BUILDING STANDARD STOREFRONT DOOR WOOD DOOR WITH RF -LITE WOOD DOOR HOLLOW METAL DOOR WOOD SLIDING DOOR (PXISTIN6) (EXISTING) 14.) 11 giligilkih. 0 3 5.7 REVIEWED FOR CODE COMPLIANCE APPROVED DEC: 102013 s. City of Tukwila � BUILDING'_ DIVISION RECEIVED CITY OF TUKWILA NOV 212 2013 PERMIT CENTER Y:1Architectural Projects113131A13-35215 CURRENT PHASE DWGS12 Sheets1A13-352 A9.00.dwg Nov 18, 2013 - 2:34pm kmcgough fry '„ 40 10401 AT SOUTHCENTER S REGISTERED AR HIT • SEPH C PAL '" IST STATE OF WASHINGTON A9.00 PROJECT NUMBER: A13.351118113 0 FREIHEIT & HO ARCHITECTS, INC., P.S. (EN -0I) (EN -05) (EN -o8) = MEN'S RESTROOM 106 GFI MEP +4 'p4OM E N'S RESTROOM 105 FE TREATMENT ROOM #1 104 E!] — x.26 -p1 5FI L E TREATMENT ROOM #2 103 FACIAL ROOM #1 102 +.42 N u— 26-N 41 N(fl) [ID FACIAL ROOM #2 101 +54 N NON-GFI N GFI (E) V.I.F. (EN -0q 0 0 +42N +60N (EN -07 LIFIJENt 1110 I BREAKROOM 107 N N • 5FI — t4, N 1177675171 N 26N N DRYER WASHER STORAG E 109 (EN -02 STORAGE 108 COUPLES TREATMENT 112 TREATMENT ROOM #3 114 2�r 611 +4/ TREATMENT ROOM #4 113 FACIAL ROOM #3 115 +GF 42 IMS' +26 OFFICE 116 RECEPTION 100 Y:IArchitectural Projects11313W13-35215 CURRENT PHASE DWGS12 Sheets1A13-352_E1.00.dwg Nov 18, 2013 - 2:35pm kmcgough N -G N% N N ELECTRICAL PLAN SCALE: I/4" = i' -O" ELECTRICAL PLAN KEYNOTES ELECTRICAL GENERAL NOTES DOUBLE GANG QUAD-PLEX POWER OUTLET ON DEDICATED 20 AMP CIRCUIT MOUNTED UNDER DESK. (EN -02) PROVIDE POWER A5 REQUIRED FOR WATER HEATER. (EN -D3) (EN -04) (EN -06) (EN -07) (EN-oq) DOUBLE GANG .UNCTION BOX AT MIN. 18" AFF FOR DATA LINES. PROVIDE (2) I" CONDUITS WITH PULL STRINGS FROM BOX TO ABOVE ACCESSIBLE CEILING. PROVIDE CONDUIT AND PULL CORD FROM THIS LOCATION TO TELEPHONE DEMARCATION ROOM; PROVIDE 10 GAUGE GROUND WIRE FROM BACKER BOARD INTO GROUND BLOCK PER SPECIFICATION MANUAL. VERIFY LOCATION ON SITE AND WITH OWNER. PROVIDE POWER A5 REQUIRED FOR TENANT PROVIDED REFRIGERATOR.. EXISTING ELECTRICAL PANEL LOCATION. PROVIDE POWER AS REQUIRED FOR TENANT SUPPLIED MICROWAVE. OUTLETS ON SAME CIRCUIT. PROVIDE AND INSTALL DEDICATED OUTLET TO TENANT SUPPLIED AND INSTALLED WASHER, ELECTRIC DRYER, AND REFRIGERATOR. I. DATA AND PHONE WIRING WILL BE BIDDER DESIGNED AND PROVIDED AS A PART OF THE CONTRACTOR'S SCOPE OF WORK. 2. INSTALL ALL OF TENANT'S REQUIRED INCOMING PHONE, DATA AND FAX LINES. VERIFY NUMBER OF INCOMING LINES AND THE TERMINAL CONNECTION LOCATIONS WITH THE TENANT. 3. PROVIDE DEDICATED NEUTRAL WITH AN UNBROKEN GROUND WIRE BACK TO THE PANEL FOR TENANT'S EXTERIOR SIGNS; VERIFY EXACT REQUIREMENTS AND LOCATIONS WITH SIGN PROVIDER. 4. REFER TO HAND $ STONE CORPORATE SPECIFICATION MANUAL FOR MORE INFORMATION. 5. ALL RECEPTACLES AT 18" A.F.F. UNLESS NOTED OTHERWISE. b. ALL OUTLETS TO HAVE (2) OUTLETS PER CIRCUIT. 7. ALL ELECTRICAL TRIM TO BE BUILDING STANDARD COLOR. 8. PROVIDE BOX, TRIM, 3/4" CONDUIT TO CEILING AND PULLSTRIN6 AT EACH VOICE/ DATA LOCATION. COORDINATE WITH TENANT'S LOW VOLTAGE VENDOR FOR GABLE INSTALLATION. q. VERIFY AND COORDINATE ALL EQUIPMENT ELECTRICAL AND DATA REQUIREMENTS AND LOCATIONS WITH FUTURE TENANT PRIOR TO INSTALLATION. 10. ALL NEW SWITCHES SHALL BE AT 48" A.F.F. UNLESS NOTED OTHERWISE. II. PROVIDE AUTOMATIC SHUT-OFF CONTROLS PER NREC 15.13.6. LEGEND 4 220V GPI +48 N DED ELECTRICAL DUPLEX OUTLET (I) EA. PHONE AND DATA JACK ON A SINGLE PLATE ELECTRICAL QUAD OUTLET 200 VOLT DUPLEX OUTLET GROUND FAULT INTERRUPTER MOUNT OUTLETS JACKS AT INDICATED HEIGHT ON CENTER. INDICATES 'NEW' INDICATES 'EXISTING' INDICATES 'EXISTING' - TO BE DEMOLISHED J -150X INDICATES DEDICATED CIRCUIT bF?r 6 SEPAp, RIWITANO APPREQUIRED3V,� RECEIVED CITY OF TUKWILA NOV 2 2 2013 PERMIIT CENTER AT SOUTHCENTER S DESORiPliON CHECK !SET PERMEf' SET E1.00 CV PROJECT NUMBER: A13.35/ 1118113 0 FREIHEIT & HO ARCHITECTS, INC., P.S. O BREAKROOM STORAGE TREATMENT ROOM #1 104 COUPLES • TREATMENT 112 • TREATMENT ROOM #2 TREATMENT ROOM #3 114 TREATMENT ROOM #4 FACIAL ROOM#3 OFFICE FINISH PLAN FI.00 Y:1Architectural Projects113131A13-35215 CURRENT PHASE DWGS12 Sheets1A13-352_F1.00.dwg Nov 18, 2013 - 2:36pm kmcgough SCALE: 1/4" = I'-0" FINISH LEGEND LEGEND CODE MANUFACTURER GENERAL LOCATION PAINT ALL PAINT TO BE P -I UNLESS NOTED OTHERWISE P -I P-2 P-3 CARPE CPT -I PRODUCT: INTERIOR COMMERCIAL GRADE PAINT MANUFACTURER: VALSPAR HOMESTEAD RESORT COLOR: CAMEO WHITE; 7002-21 SHEEN: EGGSHELL FINISH SATIN FINISH AT DOORS 4 WINDOW FRAMES SOURCE: HAND 4 STONE; NICK MALONE; 60q -587-g800 FIELD PAINT THROUGHOUT U.N.O. DOORS 4 WINDOW FRAMES PRODUCT: INTERIOR COMMERCIAL GRADE PAINT MANUFACTURER: BENJAMIN MOORE CLASSIC COLOR: PERSIAN MELON; *111 SHEEN: EGGSHELL FINISH SOURCE: HAND 4 STONE; NICK MALONE; 60q -587-g800 TREATMENT ROOMS ACCENT PAINT PRODUCT: INTERIOR COMMERCIAL GRADE PAINT MANUFACTURER: BENJAMIN MOORS COLOR: VAN DEUSEN BLUE; *HG -I56 SHEEN: EGGSHELL FINISH SOURCE: HAND 4 STONE; NICK MALONE; 6041-587-g800 FRONT COUNTER 4 LOBBY ACCENT PAINT PRODUCT: MANNINSTON CARPET TILES 24X24 FRONT COUNTER, OFFICE STYLE: SCENIC HALLWAYS, AND MASSAGE COLOR: SEASCAPE 1541607 ROOMS BASE: COVE - 4" BASE COLOR: VPI Oq AURORA INSTALLATION: MONOLITHIC SOURCE: SPARTAN SURFACES, TIM DORMER (60g) 413-2127 VINYL FLOORING V-1 PRODUCT: VINYL PLANKING MANUFACTURER: MANNIN6TON STYLE: HALO ASENTO CHERRY #5504 BASE: COVE - 4" BASE COLOR: VPI CLUB CHAIR *41 SOURCE: SPARTAN SURFACES, TIM DORMER (6041) 413-2127 FACIAL ROOMS 4 BREAK ROOM FLOORING SOLID SURFACE 0-1 0-2 PRODUCT: INDIAN DAKOTA GRANITE MANUFACTURER: TBD COLOR: TBD SOURCE: TENANT SUPPLIED PRODUCT: PROFIT ALPINE LEDGE -STONE MANUFACTURER: CULTURED STONE COLOR: HARVEST OR CHARDONNAY SOURCE: WWW. GULTUREDSTONE.COM PORCELAIN TILE T -I LOBBY COUNTER TOP FRONT DESK PRODUCT: PORCELAIN TILE RECEPTION FLOOR STYLE: MANNIN&TON COMMERCIAL - ANTIQUITY PATINA SIZE: I8XI8 COLOR: ANTIQUITY PATINA GROUT: LATIGRETE 1524 NATURAL GRAY BULLNOSE: 3X12 BASE: TILE SOURCE: SPARTAN SURFACES, TIM DORMER (6041) 413-2127 PRODUCT: PORCELAIN TILE RESTROOM FLOOR 4 WALL STYLE: MANNIN6TON COMMERCIAL - ANTIQUITY PATINA SIZE: 12X12 COLOR: ANTIQUITY PATINA GROUT: LATIGRETE 1524 NATURAL GRAY BASE: TILE SOURCE: SPARTAN SURFACES, TIM DORMER (60q) 413-2127 PLASTIC LAMINATE PL -I PL -2 PL -3 DOORS PRODUCT: PLASTIC LAMINATE MANUFACTURER: WILSONART STYLE: MYSTIC GEMSTONE; *I830K-35 SOURCE: WWW.WILSONART.COM PRODUCT: PLASTIC LAMINATE MANUFACTURER: WILSONART STYLE: WILLIAMSBURG CHERRY; #7g36K-07 SOURCE: WWW.WILSONART.GOM PRODUCT: PLASTIC LAMINATE MANUFACTURER: WILSONART STYLE: CAFE CREME; *D456-60 SOURCE: WWW.NILSONART.COM PRODUCT: DOOR STAIN MANUFACTURER: MINWAX STYLE: WOOD FINISH SATIN COLOR: ENGLISH CHESTNUT *233 SOURCE: WWW. MINWAX.GOM COUNTERTOP THROUGHOUT ROOMS U.N.O. CABINETRY FINISH THROUGHOUT ROOMS U.N.O. RETAIL BACK PANELS ALL DOORS I• I It I I• INDICATES EXTENT OF ACCENT PAINT WALL; CONFIRM LOCATIONS AND COLORS WITH TENANT PRIOR TO PAINTING FINISH NOTES I. INTERSECTION OF SCHEDULED FLOORING MATERIALS ARE TO OCCUR AT CENTERLINE OF DOOR WHEN IN A FULLY CLOSED POSITION UNLESS NOTED OTHERWISE. 2. ALL SHCETROGK SHALL RECEIVE PAINT AS SPECIFIED. PAINTING AND REPAIR OF EXISTING WALLS SHALL BE UNIFORM AND EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS CORNERS, CEILING LINES, TOP OF BASES AND SIMILAR. 3. PROVIDE APPROPRIATE TRANSITION MATERIAL AS REQUIRED WHERE DISSIMILAR FLOORING MATERIALS INTERSECT. 4. PATCH 4 REPAIR ALL FLOORS, WALLS, AND CEILINGS, AS REQUIRED BY DEMOLITION AND NEW CONSTRUCTION. ALL SURFACES ARE TO BE UNIFORM AND IN "LIKE -NEW" CONDITION. 5. WALL PARTITIONS TO RECEIVE PAINT AS A FINISHED SURFACE WILL RECEIVE A PRIMER (IF NEN AND A MINIMUM OF TWO ADDITIONAL COATS OF SPECIFIED FINISH PAINT. FINISHEDSURFACES SHALL APPEAR EVEN, WITHOUT VARIATION IN COLOR, DENSITY OR REFLECTIVITY. COLORS TO BE SUBMITTED AND APPROVED IN WRITING BY TENANT PRIOR TO INSTALLATION. 6. NOT USED. 7. NOT USED. 8. REFER TO HAND 4 STONE CORPORATE SPECIFICATION MANUAL FOR MORE INFORMATION. q. PROVIDE 2% ATTIC STOCK OF FINISH MATERIALS INCLUDING, PAINT, CEILING TILES, CARPET TILE, WALL BASE, AND PORCELAIN TILE 10. BID ADD/ ALTERNATES: 10.1 SOLID SURFACE (0-1) AT RECEPTION TRANSACTION TOP. 10.2 MILLWORK/ CASEWORK FURNISH 4 INSTALL 103 UNFAGED INSULATION ABOVE GEILIN6 TILE IN SPECIFIC ROOMS PER CN -05 ON A7.00 10.4 LOW VOLTAGE WIRING (SOUND, FIRE ALARM, ETC.) tL3O3s L4?t4 RECEIVED CITY OF TUKWILA NOV 2.2 2013 PERMIT CENTER If is fa r. .4 14.1 0 11111M1 Na ila 4111 IIID GI t• AT SOUTHCENTER S REGISTERED ARCH IT T SEPH C PA 1ST STATE OF WASHINGTON REV F1.00 Its DATE 11/04113 $FRE HE T & HO ARCHITECTS, RIC., P.S.