Loading...
HomeMy WebLinkAboutPermit D13-0363 - VEGA HELMET - TENANT IMPROVEMENTVEGA HELMET 18200 OLYMPIC AVE S D13-0363 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov DEVELOPMENT PERMIT Parcel No: 7888900162 Permit Number: D13-0363 Address: 18200 OLYMPIC AVE S Issue Date: 12/19/2013 Permit Expires On: 6/17/2014 Project Name: VEGA HELMET Owner: Name: EPROPERTY TAX INC DEPT 207 Address: PO BOX 4900 , SCOTTSDALE, WA, 85261 Contact Person: Name: DON WYTKO Phone: (425) 656-0683 Address: 18200 OLYMPIC AV S , TUKWILA, WA, 98188 Contractor: Name: CEDAR RECYCLING INC Phone: (253) 804-0404 Address: 411 W VALLEY HWY 5 , PACIFIC, WA, 98047 License No: CEDARRI981CM Expiration Date: 2/18/2014 Lender: Name: N/A ( $5,000 Address: DESCRIPTION OF WORK: INSTALLING STORAGE RACKS AND ANCHORAGE TO FLOOR Project Valuation: $1,763.28 Fees Collected: $203.99 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: VB Occupancy per IBC: S-2 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: • • Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 01/?//_3 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: aieg % &(/k PC.0" Date: ! i(?'(7p This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Installation of high-strength bolts shall be periodically inspected in accordance with AISC specifications. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. • . 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: Clearance between ignition sources, such as Tight fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 10: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one-hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 11: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 12: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 13: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 14: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC 3;(1 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov udd'ing Permit No. p - 9 ? p3 Project No. Date Application Accepted: Date Application Expires: 19 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION fi King Co Assessor's Tax No.: Site Address: 18200 Olympic Ave S, Tukwila, WA 98085 Suite Number: Tenant Name: Vega Helmet PROPERTY OWNER Name: .,,, W,3�kc, Name: Eproperty Tax Inc Address: L $ zoo 0 Address: 18235 Olympic Ave S City: --��Lw, `q State: City: Tukwila State: WA Zip: CONTACT PERSON — person receiving all project communication Name: .,,, W,3�kc, Address: 4 it cA, va11eAs HW 5 Address: L $ zoo 0 Phone: Z > l goii , 04014 Fax:2 - - ?vitt_ 21 G L City: --��Lw, `q State: »Ac. Zip4 slow Phone: Li 2g_ %S(0. ij%& ax: City: Email: aor.0 wVv.B.L►sA.,•... '. Co/VI GENERAL CONTRACTOR INFORMATION Company Name l r Address: 4 it cA, va11eAs HW 5 City:?GrcY- Ste: 1 Zip oci 7 Phone: Z > l goii , 04014 Fax:2 - - ?vitt_ 21 G L Contr RegNcy; o guiz 1 et g 1 Exp Date:z 114 i Tukwila Business License No.: H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-I l.docx Revised: August 201 I bh 7Mrs d(s� Floor: New Tenant: ❑ Yes ❑ ..No ARCHITECT' OF_ RECORD Company Name: Rack Design and Engineering Company Name: Address: 412 West Broadway Ste # 204 Architect Name: Phone: Fax: Address: City: State: Zip: Phone: Fax:..,:.:..:, Email: ENGINEER OF RECORD Company Name: Rack Design and Engineering Engineer Name: Garnik Ohanian Address: 412 West Broadway Ste # 204 City: Glenndale State: CA Zip: 91204 Phone: Fax: Email: gorackl@yahoo.com LENDER/BOND`ISSUED (required for, projects $5,000 or greater per RCW 19.27.0,95). ,.;„a, _,,_ Name: Address: City: State: Zip: Page 1 of 4 :BUILDING PERMIT IN" FORMAgTI(S NI -3670" Valuation of Project (contractor's bid price): $ (1 to 3 . Zfs Describe the scope of work (please provide detailed information): Will there be new rack storage? ❑ Yes Existing Building Valuation: $ inftIM m.. No If yes, a separate permit and plan submittal will be required. r Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary` es deuce Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 YesNo If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Sa ty Data Sheets. SEPTIC SYSTEM 0 On-site Septic System – For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel " Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor V— f S -I 2nd Floor 3rd Floor Floors thru Basement moi r. .. Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary` es deuce Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 YesNo If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Sa ty Data Sheets. SEPTIC SYSTEM 0 On-site Septic System – For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PERMITA'PPLICATION (NOTES-- Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ()VAR OR AUTH RIZED AGENT: Signature: av Print Name: PO rt / /to /i w f'7 Mailing Address: (Ti Uf MAtT /'1 w f H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11 .docx Revised: August 2011 bh Day Telephone: Date: 6() ‘;57_? (1,4 777sir City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY I PAID $203.99 D13-0363 Address: 18200 OLYMPIC AVE S Apn: 7888900162 $203.99 DEVELOPMENT $203.99 PERMIT FEE R000.322.100.00.00 $120.90 PLAN CHECK FEE R000.345.830.00.00 $78.59 WASHINGTON STATE SURCHARGE TOTAL FEES PAID BY RECEIPT: R240 B640.237.114 $4.50 $203.99 Date Paid: Tuesday, December 03, 2013 Paid By: SOARING HELMET CORPORATION Pay Method: CHECK 22402 Printed: Tuesday, December 03, 2013 2:40 PM 1 of 1 riWSYSTEMS INSPECTION RECORD Retain a copy with permit, l 3 -03 (Q 3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: 14d.Akt Typeof lnsRection:.\Ve.c4- t J . -f, ,U.A� Address:„ 1 �2D a d A'1P, Date Called: ,E joo Special Instructions: ....----- r j l / Date Wanted: / 3 —r ! -( �a,. p.m. Requester: Phone IV: 1 [._s ” 65 W -. 0 I (0 J Approved per applicable codes. Corrections required prior to. approval. COMMENTS: "40 v. Insector: Date: -REINSPECTION FEE. REQUIRED.. Prior to next inspection, fee must be paid at -6300 Southcenter Blvd:, Suite 100. Call to schedule reinspection. INSPECTION NUMBER. INSPECTION RECORD Retain a copy with permit i/3- a363 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Ve /!If Type of Inspection: -F,i PA -L Address: / saw Suite #: p l Vroio,C, Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: -C pc — � k Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: NA cvk _0_, Date: 3////7 Hrs.:' $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Fireproofing Aggregates Shotcrete Concrete Masonry Asphalt Roofing Piling S t e el Soils Wood March 11, 2014 File No. 14-187 Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Vega Helmet Address: 1 Permit: D1- 0363 Ave. S. A.A.R. TESTING LABORATORY, INC. COI ISTRLCTION INiPECTION AND MATERIAL TESTINC. NATIONALLY ACCEPTED LABORATORY RECEIVED CITY OF To;mia. MAR 1 1 2� PERMIT CENTER This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our inspection report is attached. 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans; specifications, IBC and related codes and/,or verbal or writteninstructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. ae.w662 Kimberle Anderson President CC: Vega Helmet -Don Wytko Y Tel: (425) 881-5812 Fax (425) 881-5441 0 7126 180th Ave. NE 0 P.O. Box.2523 0 Redmond, WA 98073 Client: Vega Helmet 18200 Olympic Ave. S. Tukwila, WA 98188 Contact: Don Wytko Field Report Report #: 058931 Project Number: 14-187 Permit #: 013-0363 Project Name: Vega Helmet Address: 18200 Olympic Ave. S. Inspection Performed: Proprietary Anchors Date: 2/24/2014 Time: Temperature: Anchor bolts for pallet racks per Rusty Racks drawing #1. Verified installation of Simpson Strong bolt 2 anchors 1/2" x 4 3/4" with 3 1/4" embed, torqued to 60 ft./lbs. All placed per plan. RECEIVED CITY OF TUKWI ..r'? MAR 1 1 �u,t PERMIT CENTER Distribution: Q Distribute Client ❑ Distribute Contractor El Distribute Engineer ❑ Distribute Owner Distribute Municipality ❑ Distribute Other [] Distribute Architect ❑ Distribute Other Inspector: Trow, Michael Reviewed by: Michele Guerrini All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden BY G. OHANIAN DATE . 11-21-13 SUBJECT RAdK DENI(N & ENOINEERINd do. 412 WEOT BROADWAY, piUITE #204 dLENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 1 JOB NO.. RD -17073 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: VEGA HELMETS 18200 OLYMPIC AVE. SOUTH -TUKWILA, WA 98055 PER IBC 2012 EDITION SECTION 2209 STORAGE RACKS CAPACITY: 2000 # / LEVEL CALCS. 1 THRU 4 Pit E Cop Plift our. Pe, sk EXPIRES 12-26-15 REVIEWED FOR CODE COMPLIANCE CE APPROVED DEC 13 2013 City of Tukwila BUILDING DIVISION 13-0 3 10 3 • RECEIVED CITY OF TUKWILA DEC; 0 3 2013 PERMIT CENTER BY G. OHANIAN DATE 11-21-13 SUBJECT RAdK DEIGN & ENGINEERING CO. 412 WEST BROADWAY, QUITE #204 dLENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3613 SHEET NO. 2 JOB NO.. RD -17073 BEAM 0 M SEISMIC DESIGN _ SDSXI V- Rx 1.4 Ix =1.95 Sx =1.04 - FY - 55 KSI. LOAD PER BEAM + 25% IMPACT LOAD (2.OKx.88)+(1.OKx.25) = 2.0= 1.0K 2 BEAMS M= 8z =15"K SR= .46<1.04 0- 5xwL4 =. 384.1 E 39"<1k0 =.67" x xW IBC 2012 (SEC. 2209), RMI SPECS. ASCE 7-10 (SEC. 15.5.3) S05=0.95 (USGS WEB SITE, "SITE CLASS D") 1=1 NO PUBLIC ACCESS R=6 MOM. CONN. R=4 BRACED W=D.L.+ 3 PALLET LOAD LOAD PER COL - 2x2.0 K =2.0 K 2 cot.. P=.2DL+ (2.0Kx0.75)=1.7K W=.2DL+ (2.0PLx0.67)= 1.5 K \L= .17K ONGIT. V = .26K TRANS. COLUMN ANALYSIS 3" 0 x- - - x I t=.070" 1J COMBINED STRESS RATIO Pe x- (2 = 20.0 ax=1 Qcip Pex = .84 FY=55 KSI Ae=.62 Ix=.95 Se=.6 rx=1.2 ry=1.1 Qc=1.8 Ob=1 .67 Cmx=.85 LONGIT. SEISMIC 12K 4.2"K 06K 4.2" KL _70x1.7 =99 rx 1.2 KL_ 42 ry x=38 Mr, =Se .Fy=35 Qc.P f2b.Cmx.M = 77<1 P„ Mn.ax 17K 2 Fe=(KL)2=30 rx 2 Fr,=Fy(.658 �c )=25 KSI Pn= Fr, .Ae = 16.0 K 0 11.8"K ac=V'Fy/Fe = 1.36 Nc<1.5 BY G. OHANIAN DATE. 11-21-13 SUBJECT RACK DEOION & ENdINEERIN(4 CO. 412 WEOT BROADWAY, OU1TE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 3 JOB NO.. RD -17073 BASE PLATE ANCH. TENSION = 0 ANCHOR SHEAR = .17 K (1)-1/2"0 ANCHOR PER BASE PL., 3 1/4" EMB. SIMPSON STRONG BOLT 2 ESR -3037 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION 1 K 3"x5"x1/8" BASE PLATE .5x.07x 1x65=2.3 K BEARING CAPACITY OF COL. HOLE 4.2 "K 8.0 "K ® ®' 8.0"K 7/16"0 RIVET A=.1 Fy79KSI Pa = .1 x79x.4 = 3 K Ma = (2.3Kx4")+(1.1 Kx2") = 11.4"K 3 PIN CONN. CONN. M END - .O 1 X W 12= 1.2 "K M— 8.0"K M= 9.2-K SEISMIC TOTAL ` 11.8' OVERTURNING MOT =.26 Kx2 x 165"x0.66 = 57 "K COL. MR = 1.7 Kx48"= 82 "K NO UPLIFT .26K 1..7K 1.7K 1r. I x7f '1 I� `J .26K tO 48" TOP LEVEL LOADING W= O.2DL+1.OLL=1.2K LOAD PER COL. V= .20 K MOT = .20 Kx2 x144" = 59 "K COL. MR = 1.2 Kx48" = 58 "K UPLIFT = 59-58 .02 K BY G. OHANIAN DATE . 11-21-13 SUBJECT RAdK DEOION Sc EN(INEERINd do. 412 1PET BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 4 JOB NO.. RD -17073 LOAD TO DIAGONAL P = .26Kx2 x56 = .61 K COL. 48 FY— 55 KSI Ae=.26 rx =.48 Q=.74 L= 56" P° = 3.8K CHECK WELDS Pn= (1 .01L)L.t.Fu = 3.9 K f2 = 2.55 ED, 1.5K x2 = 3.OK SIDES CHECK SLAB 1700 = 1.7 °' 1000 1.7x144=244 =16" M= (12 12 x1000x x12=666 "# s= 1\2x62/= 72 6 666 = 9 <1.6 \/ 2500 =80 72 BOTH SIDES TYP �FX t'=.07" 1700# 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL Design,Maps Sounmary Report http://geohazards.usgs.gov/designmaps/us/summary.php?template=min.. (JSGS Design Maps Summary Report User -Specified Input Report Title 18200 OLYMPIC AVE. S., TUKWILA, WA 98055 Thu November 21, 2013 18:34:30 UTC Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.43652°N, 122.25173°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III Ognit7r` 509 Hig• hlands _....k, s f USGS-Provided Output Ss = 1.421 g S1 = 0.530 g SMs = 1.421 g SM1 = 0.795 g S0s = 0.947 g SD1 = 0.530 g 0 MapQuest For information on how the SS and Sl values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please retum to the application and select the "2009 NEHRP" building code reference document. 1.65 1.50 1.35 1.20 1.05 011 0.90 to 0.75 0.60 0.45 0.30 0.15 0.00 MCER Response Spectrum Design Response Spectrum 1.10 1.00 0.90 0.90 0.70 .31 0.60 {n 0.50 0.40 0.30 0.20 0.10 0.00 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.20 2.00 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.90 Period, T (sec) Period, T (sec) 2.00 Although this Information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. 1 of 1 11/21/2013 10:34 AN PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-0363 PROJECT NAME: VEGA HELMET SITE ADDRESS: 18200 OLYMPIC AV S X Original Plan Submittal Response to Incomplete Letter # DATE: 12-03-13 Response to Correction Letter# Revision # After Permit Issued DEPARTMENTS: ilui.ding Division Public Works n l p\-wC. Z10 j'3 Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12-05-13 Complete Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route b< Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 01-02-14 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 CEDAR RECYCLING INC 0 Washington State Department of Labor & Industries Page 1 of 3 CEDAR RECYCLING INC Owner or tradesperson ECK, JERALD D Principals ECK, JERALD D Doing business as CEDAR RECYCLING INC WA UBI No. 602 084 893 411 W VALLEY HWY S PACIFIC, WA98047 253-804-0404 KING, County Business type Corporation Governing persons JERALDDECK License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .............. .............. ... Meets current requirements. License specialties GENERAL License no. CEDARRI981CM Effective — expiration 02/14/2002 — 02/18/2014 Bond RLI INSURANCE COMPANY Bond account no. SRS1002727 Received by L&I 02/14/2002 Insurance Associated Industries Ins Co I Policy no. TBD Received by L&I 12/28/2012 Savings No savings accounts during the previous 6 year period. $12,000.00 Effective date 02/13/2002 $1,000,000.00 Effective date 12/31/2012 Expiration date 12/31/2013 httns://secure.lni.wa.Rov/verify/Detail.aspx?UBI=602084893&amp;LIC=CEDARRI981 CM&amp;S... 12/19/2013 30'8" 24'-10" • 24'410" 00 LJ' A OFFICF 48" 48" X 120'' (�; 48" X 120 24'40" 14'-0" kOLLIJP 48" X 120" 48" X 120"I 48" X;120" 51'-6" 24'-10" 25'-8" 48" X 120' 48" X{ 120" 48" X 120"I H 48" X 120" 61'-9" IXI 48" X 120" B 48" X 120'' SEPARATE PERMIT REQUIRED FOR: ebbanical Etectdcat Plumbing Gas Piping City of Tukwila BUILDING DIVISION No AEVisttt, n�;, Changes shamade to the of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional pian review fees, LEGEND [ ELS - EMERGENCY LIGHTING - SMOKE VENT • FILE COPY It REVIEWED FOR CODE COMPLIANCE APPROVED DEC 13 2013 • tL City of BUILDING Pian reoval Approf Coil'°I:+ int. coral the violation of any i8. authorize Receipt 18 ed: By ( -7,1.6 " g Date 2 City Ortbkwila BUILDING DIVISION N RECEIVED CITY OF TUKWILA DEC . 0 3 2013 PERMIT CENTER EXPIRES 12-26-15 113 0313 • as co Li. hi 10 8 N T • .. C/a "mc) •_ 00 N C611) ti• Nw`4 7E41 1.4 It S N F Cator) 21C) O U ET R3 o VL"‘,T-_CL) z 1 DRAW, BY: JL 90/13 DRAPING NO: CLOCKED BY: SHUT NO. 1 of 2 sags BOTH SIDES TYP. BRACING CONNECTION DETAIL FLOOR ANCHOR DETAIL SEE NOTES FOR SPECS 1 1/2" I .- .075 THK 1 1/4" SECT. A -A SECT. B -B 5/8" DIA. 2 HOLES 3/4 ' 3" \b/k16“ r1/2' 0 WI% 5 It 3/16" ` 1 1/2" 14 3/16"r 2 3/4" 1/8" THK. BASE PLATE DETAIL (1)-1/2"0 ANCHOR BOLT PER. BASE PL. 3 114" ENVIE., (SEE NOTE NO. 4) SINGLE D JQOC.70 ooa�gacD .375 R 2" TYP. AS NO'1'E,D 1/4" REF, a 0 0 .531 SQUARE LM2O 7 3" 1 14GA THK. 7/8" 3" 14GA ASTM A570 GR50 AS NOTED 6' Y4"O SAFETY LOCK (1000# CAPACITY) '6"C RIVET ASTM A576-9013 HOT -WROUGHT UNS 010100 GRACE C-1010 1 -*-3/4" TYP. R1/8" AS NOTED 6" LBC40 IONA RACK TYPE "A" 4" BEAM FACE YeQ SAFETY LOCK (1000# • CAPACITY) X6"0 RIVET ASTM A576-908 HOT -WROUGHT UNS 010100 GRACE C-1010 r LBC35 AS NOTED u 10' Yi" 0 SAFETY LOCK (1000#6AP,0 RINE ASTM A576 -90B HOT -WROUGHT UNS G10100 GRACE C-1010 LBC50 RACK DETAILS SCALE: %4' = 1" RACK TYPE "B" 5" BEAM FACE RACK ELEVATIONS SCALE: 3'2" = 1'-0" Nem STRUCTURAL NOTES: 1. DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE 2012 EDITION, SECTION 2209. 2. STEEL FOR ALL SHAPES FY=55, KSI. ASTM A1011 GR.55 (EXCEPT AS NOTED). 3. NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION IN THE SHOP OF THE APPROVED FABRICATOR #777 (E70XX ELECTRODES). 4. ALL ANCHORS TO BE SIMPSON STRONG -BOLT 2 ICC -ES ESR -3037, SPECIAL INSPECTION IS REQUIRED. 5. CONCRETE SLAB 6" THICK 2,500 PSI. SOIL BEARING CAPACITY 1,000 PSF. 6. STORAGE RACK CAPACITY 2,000 #/ LEVEL. 7. RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE CAPACITY OF THE RACK 2,000 #/ LEVEL). 8. STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 2" IN 10'-0" OF HEIGHT. 9.. THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP 0 THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. FIRE PROTECTION NOTES: 1. SPRINKLER DENSITY IS .395GPM OVER 2,500SQ FT. 2. SPRINKLER HEAD TEMPERATURE IS SET AT 265°F. 3. MOTROCYCLE HELMETS IN CARDBOARD BOXES, NON -ENCAPSULATED. 4. TOP OF STORED PRODUCT NOT TO EXCEED 16'-0". 5. APPROXIMATE CEILING HEIGHT 32'-0", 30'-0" CLEAR TO RAFTERS. EXITING NOTES: 1. EXTERIOR DOORS ARE 3' SWING TYPE WITH LOCKING KNOB WHICH REQUIRES NO SPECIAL KNOWLEDGE OR EFFORT TO OPEN. RACK TYPE "C" 312" BEAM FACE REVIEWED FOR CODE COMPLIANCE APPR4VED DEC 13 2013 lY 'Tukwila CI of T BUILDING DIVISION 13 RECEIVED CITY OF TUKWILA DEC 0 3 2013 PERMIT CENTER EXPIRES 12-'26-15 d 3 10 3 1 1 1 Oa to 'r • to A.r rirrril lairfMrrts S(f) DRAFN BY:: JAL SCAM: AS SHOWN DAT$: 9/30/13 DRAVING 110: CHECXRD BY: SMUT NO. 2 OF 2 SHUTS I" 10' 541 1 c� 1 1 _ __ RACK TYPE "C" 312" BEAM FACE REVIEWED FOR CODE COMPLIANCE APPR4VED DEC 13 2013 lY 'Tukwila CI of T BUILDING DIVISION 13 RECEIVED CITY OF TUKWILA DEC 0 3 2013 PERMIT CENTER EXPIRES 12-'26-15 d 3 10 3 1 1 1 Oa to 'r • to A.r rirrril lairfMrrts S(f) DRAFN BY:: JAL SCAM: AS SHOWN DAT$: 9/30/13 DRAVING 110: CHECXRD BY: SMUT NO. 2 OF 2 SHUTS