Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D13-0379 - TALL'S CAMERA - TENANT IMPROVEMENT
TALUS CAMERA 281 S OUTH CENTER MALL D13-0379 Parcel No: Address: City of Tukwila 10 • Department of Community Development =v 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 9202470010 Permit Number: 281 SOUTHCENTER MALL Issue Date: Permit Expires On: Project Name: TALLS CAMERA D13-0379 2/11/2014 8/10/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 JOSEPH SHING 808 E ROY ST , SEATTLE, WA, 98102 BAYLEY CONSTRUCTION A GEN. PTN PO BOX 9004 , MERCER ISLAND, WA, 98040-9004 BAYLECG0341C SELF FUNDED - TALLS CAMERA Phone: (206) 622-4981 Phone: (206) 621-8884 Expiration Date: 12/31/2015 DESCRIPTION OF WORK: TENANT IMPROVEMENT: EXISTING STOREFRONT & OVERHEAD DOOR TO BE REMOVED & REPLACED WITH NEW DISPLAY WINDOWS & GLASS DOORS. EXISTING FLOOR FINISH TO BE REMOVED & REPLACED WITH NEW FLOOR TILES. SOFFITS & PORTIONS OF EXISTING CEILING TO BE REMOVED. EXISTING CASEWORKS TO BE REMOVED & REPLACED WITH NEW CASEWORKS Project Valuation: $60,000.00 Fees Collected: $1,801.76 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: IIB Occupancy per IBC: M Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 021U I `� I hearby certify that I have read and eiCamined this permit and know the same to be true and correct. All provisions of law and ordinances gover irjthis work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this developm pe mit and agree to the conditions attached to this permit. Signature: Print Name: Date: ql l /l 7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 2: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 3: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 4: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 5: Maintain fire extinguisher coverage throughout. 6: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 7: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 8: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 9: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 10: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 11: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 12: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 13: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2328. (ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 14: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 15: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 16: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 17: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 18: Post address on storefront per approved Westfield standards. 21: Post address on storefront per approved Westfield standards. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 20: Any overlooked hazardous condition and/or, violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: ***BUILDING PERMIT CONDITIONS*** 23: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 24: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 25: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 26: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 27: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 28: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 29: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). • r 30: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 31: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH & GYPSUM 0406 SUSPENDED CEILING CITY OF T(JKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. t 13- 0 37 Project No. Date Application Accepted: I ?' (0' (1 Date Application Expires: 't (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 242 - 3t?Lf - tOO4* Site Address: 2 8 I OUTHCENT£R L.L- ,TL►Kwi L_A,WA 16189 Suite Number: Floor: GFout-4 o Tenant Name: TAL-L) 5 Gfi.ME New Tenant: ❑ Yes [.No PROPERTY OWNER Name: we -AFI -I- 1 1-4-c.. Address: i I Go t WI L_sk* (RE Bent 1`EVA4?-1),1 ITH +UR City: i_os ANGEi..E� State: c.A. Zip: 10026' CONTACT PERSON - person receiving all project communication Name: Jo SE..P+A SH 1,4 a Address: qj s,se,5.-r var.( S-Tver-T City: sE,d,,.r -i State: w,s, Zip: 9B log_ Phone: (240622 ,-W81 Fax: (1-0C.) 402 - 4289 Email: .l OV - +C HE- ASN' NGicifc-1u11TT . GpM GENERAL CONTRACTOR INFORMATION Company Name: Address: Address: fj,Og .%-r F.0.1. s -T -p r- T City: s -r-r Lam, State: wss, Zip: 12,102 Phone: ( ) 422-181 Fax: ( )(,s2 - 4289 City: State: State: Zip: Phone: Fax: City: State: Contr Reg No.: Phone: Exp Date: Tukwila Business License No.: H:\Applications\Fonns-Applications On Line \2011 Applications\Pennit Application Revised - 8-9-11.docx Revised: August 2011 bh ARCHITECT OF RECORD Company Name: P Stitt -LCA. me. NI-tTT Architect Name: JOSE i- 50 t t`4& Address: fj,Og .%-r F.0.1. s -T -p r- T City: s -r-r Lam, State: wss, Zip: 12,102 Phone: ( ) 422-181 Fax: ( )(,s2 - 4289 Email: Joe- Lv t.tEstit st-t t t t-tcY-►u'TT- c-.01-1 ENGINEER OF RECORD Name: € uf. j=ANCi 4 .-MLA C.A_Ivt6 Company Name: Address: Engineer Name: City: State: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: € uf. j=ANCi 4 .-MLA C.A_Ivt6 Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ Go,0Q0. 00 Describe the scope of work (please provide detailed information): -x*STMG sroP .fR-OIzT 4 oVt12+46P.A Doo - T+d 8E 1zErt D RET`t-A►cEP wiTH Os -4 DISPt..a•{ Wt 4DOveS 4 alas Doeft.s . EX151 LCa Ft.oeyRE, It4ISH -r-acs )E . fte FNt0va.0 .P•t c5 D •,v rnt •µE' FLo'R -Mums . 540tPrrs 4 F olkTtovs OF Ex t�3[ t NG C-> -I Ll t-tG. T17 8E. RE.1-40VE.P• . E I rrt,. G c.fiS ./4R s Te. 81E lzet•COVr-t) RE.AN-06_ -D W (T+t t4E.Y-e C A.S1r.V D4 5. Will there be new rack storage? ❑ Yes [ . No If yes, a separate permit and plan submittal will be required. Existing Building Valuation: $ Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes Er No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Et/ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes [r No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Fomis-Applications On Line \201 I Applications\Pennit Application Revised - 8-9-I l.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC IC Floor If Zii I) -"1Q % I l— a M. RE -TAU. 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes Er No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Et/ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes [r No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Fomis-Applications On Line \201 I Applications\Pennit Application Revised - 8-9-I l.docx Revised: August 2011 bh Page 2 of 4 - • PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNERAR AUTHORIZED ENT: Signature: Date: I 2/11/10 JS Print Name: Jo' srb1-I K ► 514 l NG. Amu ifi(,T) Day Telephone: (o) •'4 4/0 1 Mailing Address: So e, leay S" (,'. S Ed rT1, WA I O 0 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Rennit Application Revised - 8.9.11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,093.75 D13-0379 Address: 281 SOUTHCENTER MALL Apn: 9202470010 $1,093.75 DEVELOPMENT $1,093.75 PERMIT FEE WASHINGTON STATE SURCHARGE TOTAL FEES PAID BY RECEIPT: R1217 R000.322.100.00.00 B640.237.114 $1,089.25 $4.50 $1,093.75 Date Paid: Tuesday, February 11, 2014 Paid By: TALLS CAMERA CORPORATE OFFICES Pay Method: CHECK 15269 Printed: Tuesday, February 11, 2014 7:51 AM 1 of 1 CRWYSTEMS Cash Register Receipt City of Tukwila Receipt Number R433 DESCRIPTIONS ACCOUNT QUANTITY PAID $708.01 $708.01 $708.01 $708.01 $708.01 D13-0379 Address: 281 SOUTHCENTER MALL Apn: 9202470010 DEVELOPMENT PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R433 R000.345.830.00.00 Date Paid: Wednesday, December 18, 2013 Paid By: MESHER SHING MCNUTT Pay Method: CHECK 6330 Printed: Wednesday, December 18, 2013 9:15 AM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206).431-367 Permit Inspection Request Line (206) 431-2451 33 ,03 '7 Project;._�� ,/ r / 1 S L: 4k ° /A-' M Type f Inspection: t LS v . t [c, . ' i1J i4- L Addr ss: ,-St S titA-C/ Date Called: / Special Instructions: 7.- Date Wanted: 3-- — - �p.m. Requester: '. Ph? -4 34 .----5-3-6C1 Approved per applicable codes. UCorrections required prior to approval. COMMENTS: e_tch Alp re)C K 'TT D c 6-^1 ` l Inst ector: Date:3 — �- w �f REINSPECTION FEE REQ ' RED. Prior to next inspection, fee must be paid at 6300 Southcenter :.tvd.. Suite 100. Call to schedule reinspection. 4V4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 n13 -037'i Project: i "T -A- II S c-A-frtilA Type of Inspection: �-�'^ IC? . L: (14-77'11 . Address: I 5e tit Date Called: - _ Special Instructions: Date Wanted: -`---'a` ..3ry -25 ` 14 P.m. Requester: Air Phon No: - 34-53 Or Approved per applicable codes. tl Corrections required prior to approval. COMMENTS: Dat ZS -�4 REINSPECTION,F E Rf (VIREO. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 3,03'71 Project;„ Type off Inspection: q, A` Address: 2,.S/ I 5c_ il<A-q Date Called: 1 t..... Special Instructions: • r Date Wanted: 3-z,--/ p.m. Requester 1 4 rt 7 Phone No: oCo431-S3°� RZCo— Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0 -- f',-tAke I6 & `T'` 103—rR Insp¢ctor: Date! REINSPECTION FEE RrPUIRED. Prior to next inspection. fee must be paid at 6300 Southcen er Blvd.. Suite 100. Call to schedule reinspection. INSPECTION: RECORD Retain a copy with permit ,D 3 r 4311 INSP CTION NO. PERMIT. NO. y. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670. Permit Inspection Request Line (206) 431-2451 Pcgject: i Type of Inspection: ,� Addr s .Date Ste. M 1 Called: Special Instructions: Date Wanted: 3 14 c( a.roi RequesterG . Pho a No• 4 )3 0y Approved per applicable codes. Corrections required prior to approval.. COMMENTS: Date'.. I /. I I REINSPECTION FEE'REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO.. AN -3°375 . PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project__ k Apt CA A Type of Inspection: rszA-mt/NJ (- Addr Date Called: Special Instructions: Date Wanted:a -3 —5 _ 1 / 1 p.m. Requester: Phone No: QApproved per applicable codes. COMMENTS: 0 `\J Corrections required prior to approval. v� r qO 4 i C n Al Date: EllSPECTION FE REQUI ED.. Prior to net inspection, fee must be id at 6300 Southcenter Blv ., Suite 100. Cal to schedule reinspection. .y 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /— 037 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: /WS (.;;"71/6,4 Type of Inspection: /9-/C )6-4.441- 7 Address:Contact Suite #: ZB / "'Au_ Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: /as Sprinklers: 7,5 Fire Alarm: yeei Hood & Duct: Monitor: jSe ,97'1 Pre -Fire: Permits: Occupancy Type: Inspectors ,,../5-5 Date: �2il/ Hrs.: / • 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 z INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit DI -©37� PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 - Project_____ - z Type of Ins ection: Address: Suite #: /_--- / 5c ,07,11/f Contact Person: Special Instructions: Phone No. w� Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: /.7 .1,40e/7" ------- `-. 5 --�— r i rte =- r -e ,%Oit tom!% ,etc 60,'' ,4,-/ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:i 7"/: '` = - Date:-33�4r/f Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-STh- Project—:--T--- . i / I s6,--y1/4..r ok Type of Inspecti n: v co 62e v -- Address: Suite#: 2,g5I C ViA',/( Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: OX 7) 10/01 - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Hrs.: /. 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Word/Inspection Record Form.Doc 6/11/10 Zip: T.F.D. Form F.P. 113 19'-6" STOREFRONT POP OUT 6" 7'-10 1/2" SAWTOOTH FINS TO BE DEMOLISHED, P4TCHED AND PAINTED TO MATCH MALL 3'-10 3/4" 9 0 Concept Elevation Scale: 3/8"=1'-0" F664 1'-7 3/4" 6-5 3/4" 20'-0" TO CENTERLINES OF DEMISING WALLS GLASS DOORS SHOWN IN CLOSED POSITION CORRECTION WINDOW GRAPHICS BLADE SIGN LED Tv's BY OWNER 6" WIDE NEUTRAL PIER WITH 1/2" VERTICAL REVEAL ON TENANT SIDE STOREFRONT GLAZING NOTE: F!1 F c '" REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER SIGN CONTRACTOR SHALL ADHERE TO ALL LANDLORD AND MALL REQUIREMENTS ALL ELECTRICAL SIGNS SHALL BE U.L. LISTED PROVIDE SHOP DRAWINGS AND COLOR SAMPLES FOR APPROVAL. SIGN DRAWINGS ARE FOR DESIGN INTENT ONLY. SIGN CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL SIGN DESIGN AND MANUFACTURING METHODS SIGN CONTRACTOR TO PROVIDE PAPER MOCK UP FOR OWNER AND CONTRACTOR REVIEW FOR SIZE AND LOCATION PRIOR TO MANUFACTURING. TALLs CAMERA Westfield Southcenter Mall —0 379 IAM F664 MESHER SHIN G MCNUTT 1 I L 7'-10 1/2" 4 3'-10 3/4" N 1 0 7'-10 1/4" MAIN ID SIGN ELEVATION "TALL'S" DIMENSIONAL POLYCARBONATE LETTERS MATTE FINISH BACK LIGHTED " CAMERA" CURVED SIGN CABINET / RACEWAY BRUSHED ALUMINUM FINISH. PUSH THROUGH DIMENSIONAL POLYCARBONATE LETTERS WITH BLACK VINYL FACE 'since 1917" NON LIGHTED 0'-3 1/2" MAX. PROJECTION "TALL'S" LETTERING DIMENSIONAL POLYCARBONATE MATTE FINISH WITH INTERNAL LIGHTING REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION 0'-3 1/2" PUSH THROUGH POLYCARBONATE 1/2 EXPOSURE WITH BLACK VINYL FACE INTERNAL ILLUMINATION IN CURVE RACEWAY/ SIGN BAND CURVED SIGN BAND MAIN SIGN SECTION 1"=1'-0" Clear Polycarbonate @ 1/2" thick for the push thru elements w/ black vinyl applied to the faces. Clear Polycarbonate @ 3/16" thick w/ white vinyl applied to the w/ fabricated returns. SIGN MATERIAL TO MEET CLASS B RATING MAIN SIGN ISOMETRIC face RECEIVED CITY OF TUKWILA JAN 1.1 2014 PERMIT CENTER TALLs CAMERA Westfield Southcenter Mall F664 MI'M MESHER SHIN G MCNUTT 2 10'-0" TO F.F. r BLADE SIGN ELEVATION EXISTING BULKHEAD 0'-4" 0'-3" I 7 LED ILLUMINATION o PUSH THROUGH POLYCARBONATE LETTERS o J INTERNAL LIGHING BLADE SIGN DETAIL NOTE: BLADE SIGN ISOMETRIC PROVIDE ALTERNATE PRICING FOR BLADE SIGN. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION TALLs CANER A Westfield Southcenter Mall F664 MIM MESHER SHING MCNUTT �s.*. P� Makrplon® SL sheet UV resistant sign grade Makrolon® SL Sign Grade sheet is a polycarbonate product with an advanced UV resistance technology that promotes long lasting outdoor weathering performance. It features outstanding impact strength, excellent dimensional stability, high temperature resistance, and high clarity. This lightweight thermofor- mable sheet is also easy to fabricate and decorate. Makrolon SL is offered in clear, a wide range of standard sign colors, or can be custom matched to any color. The product, available in either sheet or reels, has a proven track record of outstanding performance in extreme environments and meets the UL 879 standard for electric sign components. A ten (10) year limited product warranty is available for both clear and colors for breakage resistance. Clear sheet is also covered for weathering resistance. The terms of the warranty are available upon request. Applications Flat and formed sign faces and channel letters A •®� .• - REVIEWED CODE COMPLIANCE APPROVED JAN FOR 3 1 2014 BAEER R City of Tukwila BUILDING DIVISION Typical Properties Property Test Method Units Values PHYSICAL Specific Gravity ASTM D 792 - 1.2 Refractive Index ASTM D 542 - 1.586 Light Transmission, Clear @ 0.118" ASTM D 1003 % 86 Light Transmission, B59 White @ 0.118" ASTM D 1003 % 27 Light Transmission, B54 White 0 0.150' and 0.17T ASTM D 1003 % 27 Water Absorption, 24 hours ASTM D 570 % 0.15 Poisson's Ratio ASTM E 132 - 0.38 MECHANICAL Tensile Strength, Ultimate ASTM D 638 psi 9,500 Tensile Strength, Yield ASTM D 638 psi 9,000 Tensile Modulus ASTM D 638 psi 340,000 Elongation ASTM D 638 % 110 Flexural Strength ASTM D 790 psi 13,500 Flexural Modulus ASTM D 790 psi 345,000 Compressive Strength ASTM D 695 psi 12,500 Compressive Modulus ASTM D 695 psi 345,000 Izod Impact Strength, Notched @ 0.125 ASTM D 256 ft•Ibs/in 18 Izod Impact Strength, Unnotched @ 0.125 ASTM D 256 ft•lbsM 60 (no failure) Instrumented Impact @ 0.125 ASTM D 3763 ft•lbs >46 Shear Strength, Ultimate ASTM D 732 psi 10,000 Shear Strength, Yield ASTM D 732 psi 6,000 Shear Modulus ASTM D 732 psi 114,000 Rockwell Hardness ASTM D 785 - M70 / R118 THERMAL Coefficient of Thermal Expansion ASTM D 696 in/in/°F 3.75 x 10-5 Coefficient of Thermal Conductivity ASTM C 177 BTU•in/hr•ftz °F 1.35 Heat Deflection Temperature © 264 psi ASTM D 648 °F 270 Heat Deflection Temperature @ 66 psi ASTM D 648 °F 280 Brittleness Temperature ASTM D 746 °F -200 ELECTRICAL Dielectric Constant @ 10 Hz ASTM D 150 - 2.96 Dielectric Constant @ 60 Hz ASTM D 150 - 3.17 Volume Resistivity ASTM D 257 Ohm•cm 8.2 x 1018 Dissipation Factor @ 60 Hz ASTM D 150 - 0.0009 Arc Resistance - - - Stainless Steel Strip electrode ASTM D 495 Seconds 10 Tungsten Electrodes ASTM D 495 Seconds 120 Dielectric Strength, in air @ 0.125 ASTM D 149 V/mil 380 FLAMMABILITY Flame Class 4, 0.060" UL 94 - HB Ignition Temperature, Self ASTM D 1929 °F 1022 Ignition Temperature, Flash ASTM D 1929 °F 824 CORRECTION (413-0379 RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER maKroL.one SL Makrolon® SL sheet Impact Resistance* Glass Acrylic Makrolon® SL 'Instrumented Impact per ASTM D 3763, sample thickness 0.125 -nominal 7 6 5 4 3 2 1 0 UV Weather Resistance Makrolon• SL Polycarbonate Sheet crylic 1 2 3 4 5 Years Visible yellowness at 8 or greater Regulatory code compliance and certifications UL 879: Electric Sign Components, UL File #E146154 UL 94: Flammability, UL File #E351891 Miami -Dade NOA #12-0605.05 Florida Building Code 2010 High Velocity Hurricane Zone Classified Bayer Material Science Bayer MaterialScience 119 Salisbury Road Sheffield, MA 01257 Toll Free: 800.254.1707 Fax: 800.457.3553 sfdinfo@bayer.com www.sheffieldplastics.com The manner in which you use and the purpose to which you put and utilize our products, technical assistance and information (whether verbal, written or by way of production evaluations), Including any suggested formulations and recommendations, am beyond our control. Therefore, it is Imperative that you test our products, technical assistance and Information to detemdne to your own satisfaction whether our products, technical assistance and information ere suitable for your Intended uses and applications. This application-speciflc analysis must at least include testing to determine suitability from a technical as well as health, safety, and environmental standpoint Such testing has not necessarily been done by us. unless we otherwise agree in writing, all products are sold strictly pursuant to the terms of our standard conditions of sale which are available upon request. NI Information and technical assistance Is given without warranty or guarantee and Is subject to change without notice. It is expressly understood and agreed that you assume and hereby expressly release us from all lability, in tort, contract or otherwise, Incurred In connection with the use of our products, technical assistance, and Information. Any statement or recommen- dation not contained herein is unauthorized and shall not bind us. Nothing herein shall be construed as a recommendation to use any product in conflict with any claim of any patent relative to any material or its use. No license is Implied or in fact granted under the claims of any patent ®Copyright, Bayer, 2013 Bayer, the Bayer Cross and Makrolon• are registered trademarks of Bayer MAKSL 0913 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Interior Lighting Summary - Building Area Method LTG -INT -BLD 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 E'roject Info Project Address 281 Southcenter Mall Date 5/21/2013 Tukwila, WA 98188 For Building Department Use FILE C " . Watts Proposed Applicant Name: Aida Raymundo Do Not Enter Lighting Here. Use LTG -INT -SPACE pro".""" Building Area Location (plan #, room #, or ALL) Area Description r„ Allowed Watts per ft2* Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) REVIEWED FOR CODE COMPLIANCE APPROVE() * Lighting Power Allowances per Table C405.5.2(1) Total NAA 31 2014 Do Not Enter Lighting Here. Use LTG -I Building Area Location (plan #, room #, or ALL) Fixture Description (Include exempt equipment per Note 5) Number of Fixtures Watts/ Fixture Watts Proposed REVIEWED FOR CODE COMPLIANCE APPROVE() NAA 31 2014 • City of Tukwila i BUILDING DIVISION F Notes: 1. Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Type. Trading wattage between Building Area types is not allowed under the Building Area Method compliance path. 2. Proposed fixtures must be listed in the building area in which they occur. Include ALL fixtures. 3. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 4. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 5. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. bo37? RECEIVED CITY OF TUKWILA DEC 1 8 2013 PERMIT CENTER 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 281 Southcenter Mall Date 5/21/2013 The following information in the 2012 Washington is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section C405.2) I -C405.2.1 Manual lighting controls Lighting control schedule with type, locations served, 50% lighting reduction method C405.2.2.1 Automatic time switch controls Lighting systems automatic shut-off capability - indicate method and location served on plans. Note locations where automatic shutoff is provided by other method (occupancy sensor, daylight controls, etc) Override switching Schedule with locations served - no single override switch exceeds an area of 5,000 SF C405.2.2.2 Occupancy sensors Schedule of locations served C405.2.2.3 Daylight zones Vertical fenestration Primary and secondary daylight zone areas indicated on plans Skylights Skylight daylight zone areas indicated on plans 405.2.2.3.; Daylight zone controls Lighting control schedule with dimming method and locations served - no single daylight control zone exceeds 2,500 SF C405.2.3 Specific application controls Specific application lighting controls are independent of general area lighting and controls for other lighting applications Means of egress lighting Lighting control schedule with method and locations served. Note luminaires that function as both normal and egress. Display lighting Lighting control schedule with type and locations served Accent lighting Lighting control schedule with type and locations served Hotel/motel guest rooms Lighting control schedule with type and locations served Supplemental task lighting Lighting control schedule with type and locations served Non-exempt lighting equipment Lighting control schedule with type, applications served and locations Non-exempt lighting equipment Lighting control schedule with type, applications served and locations C405.2.4 Exterior lighting controls Lighting control schedule with type, features and location served INTERIOR LIGHTING POWER (Section C405.5) C405.5.1 Total connected lighting power Schedule with fixture types, lamps, ballasts, watts per fixture Space exceptions Space exceptions taken noted on plans or compliance form Lighting equipment exceptions Equipment exceptions taken noted on plans or compliance form C405.5.2 Lighting power calculations Building Area Method Compliance form completed — proposed wattage per building area does not exceed maximum allowed wattage Space -By -Space Method Compliance form completed — total proposed wattage does not exceed maximum allowed wattage C405.4 Exit signs All internally illuminated exits sign are < 5 watts per side EXTERIOR LIGHTING POWER (Section C405.6) C405.6.2 Total connected lighting power Schedule with fixture types, lamps, ballasts, watts per fixture Exterior application exceptions Exterior application exceptions taken noted on plans or compliance form Lighting power calculations Compliance form completed — proposed wattage for exterior lighting plus base site allowed does not exceed max. allowed C405.6.1 Exterior building grounds lighting Schedule with fixture types, lamps, ballasts, watts per fixture; lumens per watt for fixtures > 100 watts 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 281 Southcenter Mall Date 5/21/2013 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2012 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ELECTRICAL POWER SYSTEMS (Sections C405.7 ,C405.9, C405.12, C409.2.1) C409.2.1 Electrical energy consumption — whole building Meters provided for whole building electric energy usage C405.7 Electrical energy consumption — dwelling units Individual dwelling unit electricity meters provided C405.9 Transformers Indicate transformer size and efficiency on plans C405.12.1 Variable speed escalators and moving walks Variable speed controls provided C405.12.2 Regenerative drives Variable frequency regenerative drives provided for escalators COMMISSIONING (Sections C405.13, C408.3, C409.4.4) C405.13 Commissioning Commissioning procedure developed for all applicable systems C408.3 Lighting controls Commissioning plan and functional test procedure developed C409.4.4 Electrical energy consumption meters Commissioning plan and functional test procedure developed Escalators & moving walks Commissioning plan and functional test procedure developed If "no" is circled for any question, provide explanation: 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Interior Lighting Summary LGT-SUM 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address 281 Southcenter Mall Date 5/21/2013 Tukwila, WA 98188 For Building Department Use PILE CO �+^ py Applicant Name: Aida Raymundo Applicant Address: 8o8 East Roy Street, Seattle, WA 98102 ApplicantPhone: (206) 622-4981 Pro '.rla Project Description r• ❑ New Building ❑ Addition ❑ Alteration J Plans Induded Lighting Compliance Path 0 Lighting Power Density Calculations Q Total Building Performance (If Total Building Performance then only LGT-CHK is required.) Interior Lighting Compliance Option 0 Building Area Method QQ Space -by -space Method RFVIF WE® FOR Interior Lighting System Description Briefly describe lighting system type and features. Track Spots, Recessed Downlights and Fluorescents i Track Spots and Strip Lights at caseworks. t a e j►PPOMPLIANCE ROVED JAN 3 1 2014 City of Tukwila Additions and Change of Space Use (C101.4.3 & C101.4.4) Bull -LING DIVISION 1 4 ❑ Addition area or Change of Space Use area complies with all applicable provisions as stand alone project Addition area or Change of Space Use area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use scope. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) .1 60% or more of luminaires in space replaced Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed and proposed (including existing) lighting wattage of project scope ❑ Less than 60% of luminaires in space replaced Provide Space -by -space Method (LTG -INT -SPACE) Compliance Form. Document existing total wattage in space and proposed (including existing) lighting wattage of project scope ❑ Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased ❑ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 ❑ New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. ❑ Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. ❑ No changes are being made to the interior lighting and space use not changed. bt3o37'? Fit(;t1VEU CITY OF TUKWILA DEC 1 8 , 2013 PERMIT CENTER 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Interior Lighting Summary - Space -by -Space 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 LTG -INT -SPACE Revised June 2013 Project Info Project Address 281 Southcenter Mall Date 5/21/2013 Tukwila, WA 98188 For Building Department Use Vestibule Applicant Name: Aida Raymundo Maximum Allowed Lighting Wattage Location (plan #, room #, or ALL) Space Type* Allowed Watts per ft2 Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) Vestibule Corridor/transition 0.66 61 40 Store Room/ Employees Storage 0.63 144 91 Sales/Service Retail: Sales area 1.68 1092 1835 Sales/Service 2'x2', 2 -Tube Fluorescent 7 34 Atrium** Enter Height: Sales/Service Compact Triple -Tube Fluorescent Downlight 2 3264 Retail Display Allowance from LGT-INT-DISPLAYOMEN i'• . 640 " Select Table C405.5.2(2) category from drop down menu. "" For atriums, indicate height.Allowed wattage for first 40 feet is 0.03 W/ft. ht., above 40 feet is 0.02 W/ft. ht. Proposed Lighting Wattage Total Area Allowed Watts 1297 2606 Location (plan #, room #, or ALL) Fixture Description (Include exempt equipment per Note 3) Number of Fixtures Watts/ Fixture Watts Proposed Vestibule 4', 1 -Tube Fluorescent 1 32 32 Store Room/ Employees 4', 1 -Tube Fluorescent 2 32 64 Sales/Service LED Spotlight, TL252L on Low Voltage Track, 100' long 34 13 442 with (2) Transformers, Each with 480 maximum watts Sales/Service 2'x2', 2 -Tube Fluorescent 7 34 238 Sales/Service Compact Triple -Tube Fluorescent Downlight 2 3264 Retail Display Lighting from LGT-INT-DISPLAY MERIM111111111111 1222 Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 2062 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. ' 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 nterior Display Lighting - Space -by -Space LTG -INT -DISPLAY • 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address 281 Southcenter mall Date 5/21/2013 Tukwila, WA 98188 For Building Department Use Display Case Applicant Name: Aida Raymundo Maximum Allowed Display Lighting Wattage Location (plan #, room #, or ALL) Space Type* Allowed Watts per ft2** Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) Sales/Service Retail 2: vehicles, sporting goods and small electronic 0.60 234 140 17 51 Display Window Compact Triple -Tube Fluorescent Downlight, D830 4 32 128 Display Window LED Strip, 8LX4402318W 6 23 138 Only areas within retail sales areas that contain separately controlled display light maybe entered per Table C405.5.2(2) footnoteA. ** From Table C405.5.2(2) footnote A. Total Area Area Watts 234 Display Allowance Proposed Display Lighting Wattage Only separately controlled display fixtures complying with C405.5.2(2) footnote A may entered here 140 640 Location (plan #, room #, or ALL) Display Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Display Case 39" Fluorescent, T5 10 28 280 Display Wall 36" Fluorescent, T8 25 25 625 Display Wall 24" Fluorescent, T8 3 17 51 Display Window Compact Triple -Tube Fluorescent Downlight, D830 4 32 128 Display Window LED Strip, 8LX4402318W 6 23 138 Total Proposed Watts 1222 Notes: 1. For proposed Display Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all display fixtures. • City of Tukwila Department of Community Development December 27, 2013 JOSEPH SHING 808 E ROY ST SEATTLE, WA 98102 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D13-0379 TALL'S CAMERA - 281 SOUTHCENTER MALL Dear JOSEPH SHING, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Dave Larson at 206-431-3678 if you have questions regarding these comments. • 1. Please change the code reference from 2009 IBC to 2012 IBC on page A0.0. • 2. The glazing in the store front needs to be supported on all four edges or engineered per section 2403.2 IBC. Please show compliance with section. • 3. If the new sign is made of plastic it will need to comply with section 402.6.4 IBC. Please provide a description of the materials used and confirm compliance for use in the mall relative to flame spread, class B or better. • 4. Detail 2 on page A3.2 shows a treated header. I assume this is a fire treated header. It would be allowed for use in a wall assembly, covered on both sides with drywall, but should not be exposed inside a concealed space or plenum. It would be acceptable to show it wrapped with drywall on all sides or a metal box beam might be a better fit in this detail. Please revise the details showing this beam. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted throyh the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, '2&1P-2ttQ,A Bill Rambo Permit Technician File No. D13-0379 �2nn 4E1 /In 7;.1.1.,;1.1 Ul.,el.;.,....,., 0272Q - Ul..,14.3 ')fK_d71.2F7n - l'.,,• ')n( A2 1 ?KKG �ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D13-0379 DATE: 01/14/14 PROJECT NAME: TALL'S CAMERA SITE ADDRESS: 281 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: DU Ci (Alk`IG\ Building Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator U PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 01/16/14 Structural Review Required REVIEWER'S INITIALS: DATE: CI APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Corrections Required ❑ Denied (corrections entered in views) (ie: Zoning Issues) 0 \(\( eli41\Qfk Notation: DUE DATE: 02/13/14 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-0379 DATE: 12-18-13 PROJECT NAME: TALL'S CAMERA SITE ADDRESS: 281 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued ti _ EI S: v4141. BBuillding/DDiivvi ion 4t)Ilic kr s 17 3 Fire Prevention SI . Planning DiVision Structural n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12-19-13 Complete Incomplete Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01-16-14 Approved Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 0 Ping ❑ PW 0 Staff Initials: v Documents/routing slip.doc 2-28-02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 4'1/ 14/1 if Plan Check/Permit Number: D13-379 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued 4-40, .€t.P."� NIS O Revision requested by a City Building Inspector or Plans Examiner i JAN 14 2014 PERMR CENTER Project Name: Tall's Camera Project Address: 281 Southcenter Mall Contact Person: JOE f{(t l G. Phone Number: (2.OG) 622-415 1 Summary of Revision: sr s -e TO 1TEM * : 0001:. BLLN Rti vmw 'TO 2.012. ON stili AO.D. 2) s .. G.L.ASS cLAMP.S NAvI= *+ Pro i i per> AT PLeASf. S .E PLTAt L 1 t SHF.�.T A 8.2 . 5) c..A5el• 3b MATERIAL.. }4A6 Bee -N t40-rr.) ON PETAIt_ 1� SHEET A3.2 ; 5r - E- A-TTAGE-11t1D SPELA L i&.T LOWS 4 SIGNAG,C.• 4) PICLE.- TREA'c1-D H1QADER +04re t3EG14 1? /LSaD -r SiACNCc 4w8 WRAP OPL SLL SIDES - PLEA.SL` S .e. ( 1—P4L_S 2 4 3 i SKE ET ^3.2. Sheet Number(s): AO. G 1 A 3. 2. "Cloud" or highlight all areas of revision including date of rev Received at the City of Tukwila Permit Center by: fir( • 1 IST—Entered in Permits Plus on (� "1 11 lapplicationskforms-applications on Iine\revision submittal Created: 8-13-2004 Revised: BAYLEY CONST A GEN PARTN.IP 0 Washington State Department of Labor & Industries Page 1 of 4 BAYLEY CONST A GEN PARTNRSHP Owner or tradesperson BAYLEY KEY MEMBERS INC Principals BAYLEY KEY MEMBERS INC BAYLEY HOLDINGS INC Doing business as BAYLEY CONST A GEN PARTNRSHP WA UBI No. 601 771 879 8005 SE 28th Street MERCER ISLAND, WA98040 206-621-8884 KING County Business type Partnership Governing persons !BAYLEY KEY MEMBERS p,\(\S- bgh0o'I License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. BAYLECG034JC Effective — expiration 04/03/1997 —12/31/2015 Bond Safeco Ins Co of America Bond account no. 69S001307 Received by L&I 05/11/2012 Active. Meets current requirements. $12,000.00 Effective date 04/20/2012 httns://secure.lni.wa. gov/verify/Detail.asox?UBI=601771879&LIC=BAYLECG034JC&SAW= 02/11/2014 NIM MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.632.4289 F www.meshershingmcnutt.com SOUTHCENTFIR MALL - SPACE F664 281 SOUTHCENTER MALL TUKWILA, WA 98188 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Ala BUILDING ISION 3745 REGISTERED ARCHITECT i / , STATE OF WASHINGTON J I/ SEPI K. SHING Symbol Legend Abbreviations General Notes NORTH/SOUTH GRID EAST/WEST GRID (1_ BUILDING/WALL SECTION SHEET NUMBER INTERIOR ELEVATION SHEET NUMBER ROOM NUMBER DOOR NUMBER WINDOW NUMBER DATUM POINT MATCH LINE PARTITION/WALL TYPE KEYNOTE REVISION Wall Legend # ACOUS. ADJ. ALUM. APPROX. ARCH. BLDG. BLK. BLKG. BM. BOT. C.T. C.D. CLG. CER. C.I.P. CLR. COL. CONC. COND. CONN. CONT. CORR. CTR. CTSK. DBL. D.F. DIA. DIM. DISP. DN. D.O. DR. DRWG. DS. DWR. Centerline Diameter or Round Pound or Number Acoustical Adjustable Aluminum Approximate Architect Building Block Blocking Beam Bottom Ceramic Tile Capped Drain Ceiling Ceramic Cast in Place Clear Column Concrete Condition Connection Continuos Corridor Center Countersunk JAN. JST. LAM. LAV. LT. MAX. MECH. MET., MTL. MIN. MIR. MISC. M.O. MUL. N. N.I.C. NO., # NOM. N.T.S. O.C. OFF. OPNG. OPP. 0.S. Double Drinking Fountain Diameter Dimension Dispenser Down Door Opening Door Drawing Downspout Drawer PL. PLAM. PLAS. PLYWD. PR. PT. Janitor Joist Laminate Lavatory Light Maximum Mechanical Metal Minimum Mirror Miscellaneous Masonry Opening Mullion North Not in Contract Number Nominal Not to Scale On Center Office Opening Opposite Overflow Scupper Plate Plastic Laminate Plaster Plywood Pair Point ALL WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL, COUNTY, STATE AND FEDERAL CODES AND ORDINANCES. G.C. SHALL FIELD VERIFY LEASE LINES WITH TENANT COORDINATOR PRIOR TO CONSTRUCTION OF STOREFRONT. 2. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AT THE SITE BEFORE PROCEEDING WITH WORK, AND SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY UNCERTAINTY OR DISCREPANCY. 3. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES AT THE SITE, PROTECT THEM FROM DAMAGE, AND REPORT ANY DISCREPANCY TO THE ARCHITECT PRIOR TO CONSTRUCTION. 4. THE CONTRACTOR SHALL PROVIDE ALL SHORING, BRACING, AND BARRICADING NECESSARY TO ENSURE THE STRUCTURAL STABILITY OF THE BUILDING AND THE HEALTH AND SAFETY OF THE PUBLIC AND ALL WHO ENTER THE BUILDING DURING CONSTRUCTION. 5. THE CONTRACTOR SHALL PROVIDE TEMPORARY FACILITIES AS REQUIRED BY CODE. Project Information SITE ADDRESS: PROJECT DESCRIPTION: TENANT: SOUTHCENTER MALL - SPACE NO. F664 281 SOUTHCENTER PARKWAY, TUKWILA, WASHINGTON 98188 TENANT IMPROVEMENT: REMODEL EXISTING 'TALL'S CAMERA' STORE - INCLUDES NEW STOREFRONT DOORS/WINDOWS AND RETAIL DISPLAY CASEWORKS TALL'S CAMERA, INC. 3415 SOUTH 116TH STREET, SUITE 109 TUKWILA, WASHINGTON 98168 CONTACT: BRUCE TALL TEL: (206) 988-5008 FAX: (206) 988-5002 TALL'S CAMERA SOUTHCENTER MALL - SPACE F664 6. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS INCLUDING CLEARANCES REQUIRED BY OTHER TRADES BEFORE PROCEEDING WITH THE WORK. 7. ALL DIMENSIONS ARE TO FINISHED FACE OF WALL, STRUCTURAL GRID LINE OR FACE OF EXISTING WALL UNLESS NOTED OTHERWISE. E. EA. ELEV. ELECT. ELEV. EQ. EXP. EXIST., EXIST'G. EXT. F.A. F.D. FIN. FL. FLASH. FLUOR. F.O.C. F.O.F. F.O.I.C. East Each Elevation Electrical Elevator, Elevation Equal Expansion Existing Exterior R. RAD. R.D. REF. REFR. REINF. REQD. RM. R.O. S. S.C. SCHED. WALLS TO REMAIN NEW WALLS WALLS TO BE REMOVED F.O.S. Fr. FURR. Fire Alarm Floor Drain Finish Floor Flashing Fluorescent Face of Concrete Face of Finish Furnished by Owner Installed by Contractor Face of Studs Foot or Feet Furring SECT. SH. SHT. SIM. SPECS. S.S. STD. STL. STOR. STRUCT. SUSP. SYM. GALV. G.B. G.C. GL. GYP. G.W.B. Galvanized Grab Bar General Contractor Glass Gypsum Gypsum Wallboard T.C. TEL. TEMP. THK. T.O.W. TYP. H.B. HC. HDWD. HDWE. H.M. HORIZ. HR. HT. Hose Bibb Handicap Hardwood Hardware Hollow Metal Horizontal Hour Height VERT. VEST. V.I.F. I.D. INSUL. INT. Inside Diameter Insulation Interior W. W/ W.C. WD. W/O WP. WT. Quarry Tile Riser Radius Roof Drain Reference Refrigerator Reinforced Required Room Rough Opening South Solid Core Schedule Section Shelf Sheet Similar Specification Stainless Steel Standard Steel Storage Structural Suspended Symmetrical Tenant Coordinator Telephone Temporary Thick Top of Wall Typical Unless Otherwise Noted Vertical Vestibule Verify In Field West With Water Closet Wood Without Waterproof Weight NO CHANGE IN THE SCOPE OR INTENT OF THE WORK SHALL OCCUR WITHOUT WRITTEN APPROVAL OF THE ARCHITECT. BUILDING OWNER: ARCHITECT: TAX I.D. NUMBER: WESTFIELD, LLC 2800 SOUTHCENTER SEATTLE, WA 98188 CONTACT: WAYNE JOHNSON TEL: (206) 714-3485 MESHER SHING McNUTT 808 EAST ROY STREET SEATTLE, WASHINGTON 98102 CONTACT: JOSEPH SHING TEL: (206) 622-4981 FAX: (206) 682-4289 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS N 262-304-9004 TE ' SC TION 01/13/14 PEI11IT RESUBMITTAL 9. GENERAL CONTRACTOR SHALL NOT ALLOW ANY DEBRIS TO ACCUMULATE IN STRUCTURE OR ON SITE. HAUL DEBRIS AWAY FRON SITE AND DISPOSE OF AT CONTRACTOR'S EXPENSE. 10. GENERAL CONTRACTOR SHALL PROTECT FROM DAMAGE THOSE PORTIONS OF THE BUILDING NOT IN THIS CONTRACT. ALLOW NO LEAKS IN EXISTING STRUCTURE. CONTROL SMOKE AND DUST TO PROTECT AREAS OF THE BUILDING NOT IN THIS CONTRACT. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 11. THE CONTRACTOR SHALL CONSULT WITH THE ARCHITECT TO RESOLVE ALL CHANGES, OMISSIONS, OR PLAN DISCREPANCIES PRIOR TO CONSTRUCTION. 12. THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. 13. CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES INCLUDING BUT NOT LIMITED TO: SEWER, ELECTRICAL SERVICE OR PANEL, WATER AND EXISTING HVAC (WHEN APPLICABLE), PROTECT THEM FROM DAMAGE, AND REPORT ANY DISCREPANCY TO THE DESIGNER PRIOR TO CONSTRUCTION. 14. THE CONTRACTOR SHALL SUBMIT A MINIMUM OF THREE (3) SETS OF EACH MATERIAL SAMPLE CUT SHEETS, FINISH DETAILS; SHOP DRAWINGS AND PRODUCT LITERATURE TO THE ARCHITECT FOR REVIEW. DESIGNER WILL RETAIN ONE (1) COPY OF EACH SUBMITTAL AND RETURN THE OTHERS WITH A STAMP OR REVIEW FOR RETURN TO THE CONTRACTOR PRIOR TO THE COMMENCEMENT OF CONSTRUCTION OF THE AFFECTED WORK. 15. GENERAL CONTRACTOR SHALL COORDINATE MATERIAL DELIVERIES, SUB -CONTRACTOR'S TRAFFIC AND RELATED ACTIVITIES IN ACCORDANCE WITH ALL LOCAL REGULATIONS. Code Infor t a 'o Drawing Index BUILDING CODES: CONSTRUCTION TY' - I -: - i P` • E IC• S :LE EXITS REQUIRED: 1 OCCUPANCY CLASSIFICATION: M - COVERED MALL LEASE AREA: 1297 SF OCCUPANT LOAD: 20 AREA AND OCCUPANCY: SALES AREA 515 S.F. 0 30/S.F. = 17.17 PERSONS SERVICE/STORAGE - 782 S.F. 0 300/S.F. = 2.60 PERSONS 2012 IBC WITH WASHINGTON STATE AMENDMENTS 16. THE CONTRACTOR SHALL COMPLETELY FAMILIARIZE HIMSELF WITH THE MECHANICAL AND ELECTRICAL PLANS AND SHALL PROVIDE ALL NECESSARY SHAFTS, OPENINGS, BASES, AND STRUCTURAL SUPPORT FOR DUCTS, CONDUITS, AND EQUIPMENT. TOTAL = 19.77 PERSONS SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDia tG DWI IONI ARCHITECTURAL A0.0 COVER SHEET A1.0 SITE PLAN A1.1 LOCATION/EXITING PLAN, LEASE PLAN A2.Oa DEMOLITION AT EXISTING STOREFRONT AND FLOOR DEMOLITION PLAN A2.Ob CEILING DEMOLITION PLANS A2.1 FLOOR PLAN AND CASEWORK PLAN A2.2 REFLECTED CEILING PLANS A3.1 INTERIOR ELEVATIONS A3.2 STOREFRONT ELEVATIONS AND WALL SECTIONS A4.1 INTERIOR DETAILS A5.1 CASEWORK DETAILS A6.1 ROOM FINISH SCHEDULE, DOOR SCHEDULE, DOOR AND PARTITION TYPES, FINISH MATERIALS DATE: SCALE: DRAWN: CHECKED: PROJECT NO.: 12/17/2013 NONE AR JS Accessibility Notes DURING THE COURSE OF REMODELING, NO EXISTING HANDICAP PATH OF TRAVEL, EITHER ALONG PUBLIC RIGHTS OF WAY OR THROUGH THE EXISTING BUILDING WILL BE CHANGED. 2. IF A TEMPORARY DISLOCATION SHOULD OCCUR WITHIN THE PROJECT LIMITS, TEMPORARY RAMPS OR PATHS SHALL BE CONSTRUCTED TO MAINTAIN EXISTING ACCESSIBILITY AND BUILDING OWNER SHALL BE NOTIFIED PRIOR TO SUCH DISLOCATION. A PROPOSAL MUST BE SUBMITTED FOR OWNER'S APPROVAL FOR TEMPORARY RAMPS OR PATHS. Landlord Notes CONTRACTOR SHALL READ AND FAMILIARIZE HIMSELF WITH SOUTHCENTER CONSTRUCTION RULES AND REGULATIONS IN ADDITION TO THE DESIGN AND CONSTRUCTION MANUAL. Fire Code Notes 1. IF THIS TENANT SPACE IS IN A FULLY SPRINKLERED BUILDING, THE FOLLOWING IS REQUIRED: IF IT APPEARS THAT THE PROPOSED WORK WILL REQUIRE MODIFICATION OF THIS SYSTEM. SUBMIT PLANS FOR ALL MODIFICATIONS REQUIRED BY THIS IMPROVEMENT TO THE EXISTING AUTOMATIC FIRE SPRINKLER SYSTEM TO THE BUILDING DEPARTMENT FOR FIRE DEPARTMENT REVIEW WITHIN (5) DAYS OF THE ISSUANCE OF THE BUILDING PERMIT. G.C. MUST USE WESTFIELD SOUTHCENTER REQUIRED FIRE ALARM AND SPRINKLER VENDORS. 2. IF THIS TENANT SPACE IS IN A BUILDING WHICH HAS A COMPLETE FIRE ALARM/DETECTION SYSTEM, THE FOLLOWING IS REQUIRED: IF IT APPEARS THAT THE PROPOSED WORK WILL REQUIRE MODIFCATIONS OF THIS SYSTEM. SUBMIT PLANS FOR ANY MODIFICATIONS REQUIRED BY THIS IMPROVEMENT TO THE EXISTING AUTOMATIC FIRE ALARM/DETECTION SYSTEM TO THE BUILDING DEPARTMENT FOR FIRE DEPARTMENT REVIEW WITHIN (5) DAYS OF THE ISSUANCE OF THE BUILDING PERMIT. G.C. MUST USE WESTFIELD SOUTHCENTER REQUIRED FIRE ALARM AND SPRINKLER VENDORS. FILE COPY penntt No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of an adopted code or ordiucaucce• Receipt of app -� �� . �€ RS .:, �, , PERMIT ISSUE DRAWING TITLE: DRAWING INDEX, PROJECT AND CODE INFORMATION, VICINITY MAP, ABBREVIATIONS, SYMBOLS AND NOTES 3. FAILURE TO COMPLY WITH ITEMS #1 AND #2 MAY DELAY THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 4. PROVIDE APPROVED FIRE EXTINGUISHERS OF A TYPE, SIZE AND LOCATION AS DIRECTED BY THE FIRE INSPECTOR. 5. EXIT SIGNAGE AND EXIT PATHWAY ILLUMINATION SHALL BE PROVIDED IN COMPLIANCE WITH IBC SECTIONS 1006 AND 1011 SUBJECT TO THE APPROVAL OF THE FIRE INSPECTOR. RECEIVED CITY OF TUKWILA JAN 142014 PERMIT CENTER SHEET NO.: MECHANICAL AND ELECTRICAL ON SEPARATE PERMIT A0.0 C1 Tr. • 4 LE VELS 20,4*161 ECLENCLIDED LEVEL 3 LEVELS 0SITE PLAN REVIEWED FOR CODE COMPLIANCE APPROVED JAN 31 2014 City of Tukwila BUILDING DIVISION p[3 -o371 RECEIVED CITY OF TUKWILA DEC 1 8 201 PERMIT CENTER MSM MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 REGISTERED ARCHITECT 1/ SEPH K. SHING STATE OF WASHINGTON 4, TALUS CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS NO. DATE DESCRIPTION DATE: SCALE: DRAWN: CHECKED: PROJECT NO.: 12/17/2011 AR JS PERMIT ISSUE DRAWING TITLE: SITE PLAN SHEET NO.: A1.0 j NORDSTROM EXIT EXIT F 389'-0" TO EXIT 1—HR. CORRIDOR EXIT macys 1 —HR. CORRIDOR 1 HR. ORRIDOR �rnr- n 4l4 IMP bl 4 rap' 44 7 1 e re 11_111 I b4 THIS PROJECT TALL'S CAMERA JJ n 0 0 iLYrmnyiYl SPACE F664 o a C II n >0 z U JCPenney ir--- REVIEWED FOR CODE COMPLIANCE APPROVED JAN 31 2014 City of Tukwila BUILDING DIVISION 44 coLOCATION & EXITING PLAN 1" =50'-0" TALL'S CAMERA SPACE F664 0 0 0 0 PAPER DESTINY O 0 0 co 2O'_O" 2O'—Da DJ 0 WEISFIELD JEWELERS CO Q 13-4)" q LEASE PLAN RECEIVED CITY OF TUKWILA DEC 182013 PERMIT CENTFR MSM MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 REGISTERED ARCHITECT SEPH K. SHING STATE OF WASHINGTON TALL'S CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS NO. DATE DESCRIPTION DATE: 12/17/2013 SCALE: AS NOTED DRAWN: AR CHECKED: JS PROJECT NO.: PERMIT ISSUE DRAWING TITLE: LOCATION I EXITING PLAN, LEASE PLAN SHEET NO.: A1,1 REMOVE EXISTING SIGNAGE REMOVE EXIST. SAWTOOTH FINS *64'-10" LEASE LINE DEMOLITION at EXISTING STOREFRONT SCALE: 3/8"=1'-0" NOTE: TENANT SPACE IS LOCATED ON A STRUCTURAL SLAB. ALL CUTS AND PENETRATIONS MUST BE VERIFIED AND DETAILED BY A STRUCTURAL ENGINEER. t3'-6" EXIST. 20 -MIN. DOOR TO REMAIN EXIST. ELECTRICAL PANEL TO REMAIN EXIST. 1 -HR. RATED DEMISING PARTITION TO REMAIN ,/-- EXIST. ALARM PANEL TO REMAIN EXIST. DOOR TO REMAIN EXIST. H.W.T. 1 L 1 1 1 JL 1 J II JL 1 J 1 L ABOVE TO REMAIN EXIST. SINK TO REMAIN REMOVE EXIST. SLATWALL EXIST. 20 -MIN. DOOR TO REMAIN TYPICAL DISPLAY & BASE CABINETS, I I I I I I I I I I EXIST. 1 -HR. L _ RATED WALL TO REMAIN REMOVE � I EXIST. WALL I \\ \\ •\�� REMOVE EXIST. BASE CABINETS, TYPICAL REMOVE EXIST. CARPET REMOVE EXIST. SLATWALL DISPLAY & BASE CABINETS, TYPICAL REMOVE EXIST. BASE CABINETS L NOTE: ALL FLOORS, WALLS & CEILINGS DAMAGED DURING CONSTRUCTION SHALL BE PATCHED & REPAIRED TO MATCH EXISTING, TYPICAL THROUGHOUT TENANT SPACE F FLOOR DEMOLITION PLAN EXIST. 1 -HR. RATED DEMISING PARTITION TO REMAIN *GENERAL CONTRACTOR TO FIELD VERIFY WITH TENANT COORDINATOR PRIOR TO START OF CONSTRUCTION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION CONSTRUCTION BARRICADE: COORDINATE LOCATION W/ TENANT COORDINATOR AND MALL OPERATIONS EXISTING MALL COLUMN EXISTING MALL NEUTRAL STRIP, REMOVE GRANITE LEASE LINE ACCESS DOOR REMOVE EXISTING OVERHEAD DOOR, DOOR HOUSING, POSTS & WALLS EXISTING MALL NEUTRAL STRIP, REMOVE GRANITE EXISTING MALL COLUMN SCALE: 1/4"=1'-0" DEMOLITION NOTES PATCH AND REPAIR DAMAGED FLOORS, WALLS AND ALL SURFACES AS REQUIRED TO MATCH ADJACENT EXISTING CONDITIONS FOR SMOOTH FINISH, TYPICAL THROUGHOUT. 2. NO EXISTING STRUCTURAL MEMBER SHALL BE DISTURBED OR ALTERED UNLESS OTHERWISE NOTED. REMOVE EXISTING WALLS, DOORS, FIXTURES, ETC. NOT SHOWN ON NEW FLOOR PLAN - SEE SHEET A2.1. 4. NO DUMPSTERS ARE ALLOWED ON SITE DURING MALL HOURS COORDINATE WITH SOUTHCENTER CONSTRUCTION RULES AND REGULATIONS. 5. VERIFY WITH OWNER THE DISPOSAL, STORAGE OR REUSE OF EQUIPMENT/FIXTURE TO BE REMOVED. 6. ANY EXISTING MATERIAL/EQUIPMENT NOT BEING REUSED SHALL BE COMPLETELY REMOVED AND DISPOSED OF PROPERLY ACCORDING TO APPLICABLE JURISDICTIONAL REQUIREMENTS. 7. REMOVE ALL LOOSE LYING WOOD, METAL, CONCRETE AND MISCELLANEOUS DEBRIS FROM THE PREMISES. GENERAL CONTRACTOR SHALL NOT ALLOW ANY DEBRIS TO ACCUMULATE IN STRUCTURE OR ON SITE. HAUL DEBRIS AWAY FROM SITE AND DISPOSE OF AT CONTRACTOR'S EXPENSE. 8. ASBESTOS AND ANY HAZARDOUS MATERIAL SHALL BE REMOVED AND DISPOSED OF ACCORDING TO APPLICABLE JURISDICTIONAL REQUIREMENTS. 9. EXISTING WALLS AND SURFACES WHERE NEW PIPES, CONDUIT, ELECTRICAL BOXES, ETC., ARE TO BE INSTALLED SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT EXISTING CONDITIONS AND FINISHES. 10. PIPES, DEVICES AND ALL ASSOCIATED CONDUITS AND WIRES TO BE REMOVED MUST BE DISMANTLED BACK TO POINT OF ORIGIN. PATCH AND REPAIR AS REQUIRED TO MATCH ADJACENT EXISTING FLOOR, WALL AND CEILING FINISHES. 11. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR RELATED MECHANICAL, ELECTRICAL, AND PLUMBING DEMOLITION INFORMATION. 12. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AT THE SITE BEFORE PROCEEDING WITH WORK, AND SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY UNCERTAINTY OR DISCREPANCY. 13. THE CONTRACTOR SHALL PROVIDE ALL SHORING, BRACING, AND BARRICADING NECESSARY TO ENSURE THE STRUCTURAL STABILITY OF THE BUILDING AND THE HEALTH AND SAFETY OF THE PUBLIC AND ALL WHO ENTER THE BUILDING DURING DEMOLITION. 14. THE CONTRACTOR SHALL PROTECT FROM DAMAGE THOSE PORTIONS OF THE BUILDING NOT IN THIS CONTRACT. ALLOW NO LEAKS IN EXISTING STRUCTURE. CONTROL SMOKE AND DUST TO PROTECT AREAS OF THE BUILDING NOT IN THIS CONTRACT. 15. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES INCLUDING BUT. NOT LIMITED TO: SEWER, ELECTRICAL SERVICE OR PANEL, WATER AND EXISTING HVAC (WHEN APPLICABLE), PROTECT THEM FROM DAMAGE, AND REPORT ANY DISCREPANCY TO THE ARCHITECT PRIOR TO CONSTRUCTION. 16. ALL WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL, COUNTY, STATE AND FEDERAL CODES AND ORDINANCES. LEGEND EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE REMOVED CONSTRUCTION BARRICADE br 039 RECEIVED CITY OF TUKWILA DEC 1 8 ,2013 PERMIT CENTER MSM MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 REGISTERED ARCHITECT // • / ✓ V. JSSEPH K. SHING STATE OF WASHINGTON TALUS CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS NO. DATE DESCRIPTION DATE: SCALE: DRAWN: CHECKED: PROJECT NO.: 12/17/2013 3/8"=1'-0" AR JS PERMIT ISSUE DRAWING TITLE: DEMOLITION at EXISTING STOREFRONT AND FLOOR DEMOLITION PLAN SHEET NO.: A2.Oa / / 15'-8" (EXIST. - VERIFY) I EXISTING MALL FASCIA i/ ` / I I `' — r l I I I I I I —, I I II II 11 � n nn 1 '" n I I I u Lrtl H H I `c /81 IhV4I I Ik'( iA\ I i LL ILL 1 JJ LL LL -11 L REMOVE EXISTING MIRROR BAND _Li r I L -I REMOVE EXISTING FASCIA & SOFFIT 7.1 I REMOVE EXISTING I REMOVE EXISTING WALL MALL NEUTRAL PIER - REMOVE GRANITE FROM NEUTRAL PIER TO ALLOW FOR CONSTRUCTION OF NEW NEUTRAL PIER WALL 20'-0" *64'-10" LEASE LINE DEMOLITION at EXISTING STOREFRONT SCALE: 3/8"=1'-0" NOTE: TENANT SPACE IS LOCATED ON A STRUCTURAL SLAB. ALL CUTS AND PENETRATIONS MUST BE VERIFIED AND DETAILED BY A STRUCTURAL ENGINEER. t3'-6" EXIST. 20 -MIN. DOOR TO REMAIN EXIST. ELECTRICAL PANEL TO REMAIN EXIST. 1 -HR. RATED DEMISING PARTITION TO REMAIN ,/-- EXIST. ALARM PANEL TO REMAIN EXIST. DOOR TO REMAIN EXIST. H.W.T. 1 L 1 1 1 JL 1 J II JL 1 J 1 L ABOVE TO REMAIN EXIST. SINK TO REMAIN REMOVE EXIST. SLATWALL EXIST. 20 -MIN. DOOR TO REMAIN TYPICAL DISPLAY & BASE CABINETS, I I I I I I I I I I EXIST. 1 -HR. L _ RATED WALL TO REMAIN REMOVE � I EXIST. WALL I \\ \\ •\�� REMOVE EXIST. BASE CABINETS, TYPICAL REMOVE EXIST. CARPET REMOVE EXIST. SLATWALL DISPLAY & BASE CABINETS, TYPICAL REMOVE EXIST. BASE CABINETS L NOTE: ALL FLOORS, WALLS & CEILINGS DAMAGED DURING CONSTRUCTION SHALL BE PATCHED & REPAIRED TO MATCH EXISTING, TYPICAL THROUGHOUT TENANT SPACE F FLOOR DEMOLITION PLAN EXIST. 1 -HR. RATED DEMISING PARTITION TO REMAIN *GENERAL CONTRACTOR TO FIELD VERIFY WITH TENANT COORDINATOR PRIOR TO START OF CONSTRUCTION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION CONSTRUCTION BARRICADE: COORDINATE LOCATION W/ TENANT COORDINATOR AND MALL OPERATIONS EXISTING MALL COLUMN EXISTING MALL NEUTRAL STRIP, REMOVE GRANITE LEASE LINE ACCESS DOOR REMOVE EXISTING OVERHEAD DOOR, DOOR HOUSING, POSTS & WALLS EXISTING MALL NEUTRAL STRIP, REMOVE GRANITE EXISTING MALL COLUMN SCALE: 1/4"=1'-0" DEMOLITION NOTES PATCH AND REPAIR DAMAGED FLOORS, WALLS AND ALL SURFACES AS REQUIRED TO MATCH ADJACENT EXISTING CONDITIONS FOR SMOOTH FINISH, TYPICAL THROUGHOUT. 2. NO EXISTING STRUCTURAL MEMBER SHALL BE DISTURBED OR ALTERED UNLESS OTHERWISE NOTED. REMOVE EXISTING WALLS, DOORS, FIXTURES, ETC. NOT SHOWN ON NEW FLOOR PLAN - SEE SHEET A2.1. 4. NO DUMPSTERS ARE ALLOWED ON SITE DURING MALL HOURS COORDINATE WITH SOUTHCENTER CONSTRUCTION RULES AND REGULATIONS. 5. VERIFY WITH OWNER THE DISPOSAL, STORAGE OR REUSE OF EQUIPMENT/FIXTURE TO BE REMOVED. 6. ANY EXISTING MATERIAL/EQUIPMENT NOT BEING REUSED SHALL BE COMPLETELY REMOVED AND DISPOSED OF PROPERLY ACCORDING TO APPLICABLE JURISDICTIONAL REQUIREMENTS. 7. REMOVE ALL LOOSE LYING WOOD, METAL, CONCRETE AND MISCELLANEOUS DEBRIS FROM THE PREMISES. GENERAL CONTRACTOR SHALL NOT ALLOW ANY DEBRIS TO ACCUMULATE IN STRUCTURE OR ON SITE. HAUL DEBRIS AWAY FROM SITE AND DISPOSE OF AT CONTRACTOR'S EXPENSE. 8. ASBESTOS AND ANY HAZARDOUS MATERIAL SHALL BE REMOVED AND DISPOSED OF ACCORDING TO APPLICABLE JURISDICTIONAL REQUIREMENTS. 9. EXISTING WALLS AND SURFACES WHERE NEW PIPES, CONDUIT, ELECTRICAL BOXES, ETC., ARE TO BE INSTALLED SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT EXISTING CONDITIONS AND FINISHES. 10. PIPES, DEVICES AND ALL ASSOCIATED CONDUITS AND WIRES TO BE REMOVED MUST BE DISMANTLED BACK TO POINT OF ORIGIN. PATCH AND REPAIR AS REQUIRED TO MATCH ADJACENT EXISTING FLOOR, WALL AND CEILING FINISHES. 11. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR RELATED MECHANICAL, ELECTRICAL, AND PLUMBING DEMOLITION INFORMATION. 12. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AT THE SITE BEFORE PROCEEDING WITH WORK, AND SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY UNCERTAINTY OR DISCREPANCY. 13. THE CONTRACTOR SHALL PROVIDE ALL SHORING, BRACING, AND BARRICADING NECESSARY TO ENSURE THE STRUCTURAL STABILITY OF THE BUILDING AND THE HEALTH AND SAFETY OF THE PUBLIC AND ALL WHO ENTER THE BUILDING DURING DEMOLITION. 14. THE CONTRACTOR SHALL PROTECT FROM DAMAGE THOSE PORTIONS OF THE BUILDING NOT IN THIS CONTRACT. ALLOW NO LEAKS IN EXISTING STRUCTURE. CONTROL SMOKE AND DUST TO PROTECT AREAS OF THE BUILDING NOT IN THIS CONTRACT. 15. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES INCLUDING BUT. NOT LIMITED TO: SEWER, ELECTRICAL SERVICE OR PANEL, WATER AND EXISTING HVAC (WHEN APPLICABLE), PROTECT THEM FROM DAMAGE, AND REPORT ANY DISCREPANCY TO THE ARCHITECT PRIOR TO CONSTRUCTION. 16. ALL WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL, COUNTY, STATE AND FEDERAL CODES AND ORDINANCES. LEGEND EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE REMOVED CONSTRUCTION BARRICADE br 039 RECEIVED CITY OF TUKWILA DEC 1 8 ,2013 PERMIT CENTER MSM MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 REGISTERED ARCHITECT // • / ✓ V. JSSEPH K. SHING STATE OF WASHINGTON TALUS CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS NO. DATE DESCRIPTION DATE: SCALE: DRAWN: CHECKED: PROJECT NO.: 12/17/2013 3/8"=1'-0" AR JS PERMIT ISSUE DRAWING TITLE: DEMOLITION at EXISTING STOREFRONT AND FLOOR DEMOLITION PLAN SHEET NO.: A2.Oa DEMOLITION NOTES _L _LL _LLL -LLL LLLLL. tir 4 4 �r T -------L-LLLLLL LLLLLLLLLLL I I 'LLLJLLLLLLLL 1 LLLLLLLLLLLLL TT ILLLLLLLtqi I L LLLLLLLLLLLLLLLL -LLLLLLLLLLLLLLL�. LLLLLLLLLLLLLLL LJLLLLLLLLLLLLLI.i LLLLLLLLLLLLL�L{{ LttL-LLL-CLttLLL I I LLLLLLLLLLLLLLI 1 _LLLLLLLLLLLL I _LLLLLLLLLLU LL_LLLLLLLLLI Ln LLLLLLL -LLLLL LLL I I ' LLLLLLLLLI LLLLLLL 1 I LLLLLLLLI I. LLLLLL T ----T-----1-- -HE]I I I I • LLL 1 L I I 1 I I 1 I I I II H-- ----- -1-----I _LLLLL I I I I __LLLLLLLLLLLL..IIL1 _LLLLLLL _LLLLL L. _LLLLL LL. T T \L`LLLL LLLL \ `L`LL LLLLL I I \ `L LLLLLL I 1 I _1 LZLLTI \ LLLLLIJ \ \LLI_LUL \ LL LL ---_1_ \ � �1 JI ` - �� LLLLLLL _LLLLLLL ' MOVE !STING '+-+ OVE T. CAS' ORK LtLL� _CELL1 FI& L H RLLLLyLLYLL . 6 OVOVE TING tL-LLLlllPA' :OLIC 'CRATE4 & PA' BOLIC ' GCRAT�4 L -44 `- L 0 i VE ' P L 0 R ' AN ' LLLLLLLLELLLLLL LL 41.14)..: — — — II if. .. I REM EXIST ASEW� ' L.....4 IGHT URE LI LI �I I I II x x 0 CONSTRUCTION BARRICADE LINE OF EXISTING MALL FASCIA ABOVE CEILING DEMOLITION PLAN at LOW CEILING REMOVE EXISTING SOFFIT 0 SCALE: 1/4"= 1' -0" EXISTING ACT CEILING AND LIGHT FIXTURE TO REMAIN N I- T -II I I I II 1° 4. I I I I II EXISTING ACT CEILING AND LIGHT FIXTURES TO REMAIN -1 1 I I I II CEILING DEMOLITION PLAN at HIGH CEILING 'E + /SOFF 41 0*4 tos +4 "4 (16H VI%i;RF. t sise se 4 • 4,40### 4' 84.40.84 .6&4k& • ..4W 71Prit.r.4#4$ ...41•4***** ittt.t4tit 4\ 1t*: ■ REMOVE EXISTING 2'x4' ACT CEILING AND LIGHT FIXTURES VE IN VE EXISTING 2'x2' ACT CEILING AND LIGHT FIXTURES TO REMAIN REMOVE ALL TRACK AND TRACK LIGHT FIXTURES x x x 0 CONSTRUCTION BARRICADE REMOVE EXISTING SOFFIT AND LIGHT FIXTURES REMOVE EXISTING x OVERHEAD DOOR AND HOUSING LINE OF EXISTING MALL FASCIA ABOVE SCALE: 1/4"=1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION 41) 4` PATCH AND REPAIR DAMAGED FLOORS, WALLS AND ALL SURFACES AS REQUIRED TO MATCH ADJACENT EXISTING CONDITIONS FOR SMOOTH FINISH, TYPICAL THROUGHOUT. 2. NO EXISTING STRUCTURAL MEMBER SHALL BE DISTURBED OR ALTERED UNLESS OTHERWISE NOTED. 3. REMOVE EXISTING WALLS, DOORS, FIXTURES, ETC. NOT SHOWN ON NEW FLOOR PLAN SEE SHEET A2.1. 4. VERIFY WITH OWNER THE DISPOSAL, STORAGE OR REUSE OF EQUIPMENT/FIXTURE TO BE REMOVED. 5. ANY EXISTING MATERIAL/EQUIPMENT NOT BEING REUSED SHALL BE COMPLETELY REMOVED AND DISPOSED OF PROPERLY ACCORDING TO APPLICABLE JURISDICTIONAL REQUIREMENTS. 6. REMOVE ALL LOOSE LYING WOOD, METAL, CONCRETE AND MISCELLANEOUS DEBRIS FROM THE PREMISES. GENERAL CONTRACTOR SHALL NOT ALLOW ANY DEBRIS TO ACCUMULATE IN STRUCTURE OR ON SITE. HAUL DEBRIS AWAY FROM SITE AND DISPOSE OF AT CONTRACTOR'S EXPENSE. 7. ASBESTOS AND ANY HAZARDOUS MATERIAL SHALL BE REMOVED AND DISPOSED OF ACCORDING TO APPLICABLE JURISDICTIONAL REQUIREMENTS. EXISTING WALLS AND SURFACES WHERE NEW PIPES, CONDUIT, ELECTRICAL BOXES, ETC., ARE TO BE INSTALLED SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT EXISTING CONDITIONS AND FINISHES. 9. PIPES, DEVICES AND ALL ASSOCIATED CONDUITS AND WIRES TO BE REMOVED MUST - BE DISMANTLED BACK TO POINT OF ORIGIN. PATCH AND REPAIR AS REQUIRED TO MATCH ADJACENT EXISTING FLOOR, WALL AND CEILING FINISHES. 10. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR RELATED MECHANICAL, ELECTRICAL, AND PLUMBING DEMOLITION INFORMATION. 11. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AT THE SITE BEFORE PROCEEDING WITH WORK, AND SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY UNCERTAINTY OR DISCREPANCY. 12. THE CONTRACTOR SHALL PROVIDE ALL SHORING, BRACING, AND BARRICADING NECESSARY TO ENSURE THE STRUCTURAL STABILITY OF THE BUILDING AND THE HEALTH AND SAFETY OF THE PUBLIC AND ALL WHO ENTER THE BUILDING DURING DEMOLITION. 13. THE CONTRACTOR SHALL PROTECT FROM DAMAGE THOSE PORTIONS OF THE BUILDING NOT IN THIS CONTRACT. ALLOW NO LEAKS IN EXISTING STRUCTURE. CONTROL SMOKE AND DUST TO PROTECT AREAS OF THE BUILDING NOT IN THIS CONTRACT. 14. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES INCLUDING BUT NOT LIMITED TO: SEWER, ELECTRICAL SERVICE OR PANEL, WATER AND EXISTING HVAC (WHEN APPLICABLE), PROTECT THEM FROM DAMAGE, AND REPORT ANY DISCREPANCY TO THE ARCHITECT PRIOR TO CONSTRUCTION. 15. ALL WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL, COUNTY, STATE AND FEDERAL CODES AND ORDINANCES. LEGEND EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE REMOVED CONSTRUCTION BARRICADE Q RECEIVED CITY OF TUKWILA DEC 1 8 2013 PERMIT CENTER NIM MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 REGISTERED ARCHITECT •SEPH K. SHING STATE OF WASHINGTON TALUS CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS NO. DATE DESCRIPTION DATE: SCALE: DRAWN: CHECKED: PROJECT NO.: 12/17/2013 1/4"=r-0" AR JS PERMIT ISSUE DRAWING TITLE: CEILING DEMOLITION PLANS SHEET NO.: A2.Ob FLOOR NOTES 12'-4" VERIFY 24'-0" 64'-10" LEASE LINE (V.I.F.) 24'-0" EXIST. ELEC. PANEL VERIFY EXIST. 1 -HR. RATED DEMISING PARTITION VERIFY EXIST. ALARM PANEL SERVICE CORRIDOR LINE OF VALANCE ABOVE, TYP. DISPLAY CABINET L DISPLAY CASE EXISTING COLUMN EXISTING MALL NEUTRAL STRIP WINDOW DISPLAY GLAZING MALL TILE - SEE NOTE 9, THIS SHEET STORE ROOM/ EMPLOYEES (E) FLOOR NOTE: ALL CASEWORKS ARE F.O.I.C. CERAMIC TILE, CT -1 EXIST. H.W.T. ABOVE SALES AREA EXIST. SINK LINE OF VALANCE ABOVE. TYP. DISPLAY CABINET EXIST. 1 -HR. RATED WALL EXIST. 1 -HR. RATED DEMISING PARTITION 9'-10" VERIFY FLOOR PLAN TYP. LEASE LINE: FIELD VERIFY LOCATION W/ TENANT COORDINATOR GLAZING WINDOW DISPLAY PROVIDE ACCESS PANEL FOR POWER & DATA, TYP. ON BOTH SIDES EXISTING COLUMN EXISTING MALL NEUTRAL STRIP WI 1/2" REVEAL ON TENANT SIDE, TYP. ON BOTH SIDES SCALE: 1/4"=1'-0" 12'-4" 24'-0" 64'-10" LEASE LINE (V.I.F.) 24'-0" REVIEWED FOR CODE COMPLIANCE APPROVED JAN 31 2014 City of Tukwila BUILDING DIVISION VERIFY VERIFY VERIFY VESTIBULE STORE ROOM/ EMPLOYEES 2'-f0' 3'-0" 2'-0' 4'-0" 4'-0" 4'-0" 4'-0" 3'-0" SLATWALL ONLY SERVICE POS 0 M L_ 0 A5 1 w 3'-0" ci w 1 A5.1 7'-0" 4'-0" AV J BELOW J 4'-0" I2'-0" SIM. t8'-3" L SALES AREA 30"W. DRAWER SHELF ® +34" AV BELOW -\ L L __J 0 N LEASE LINE (V.I.F.) 9'-10" VERIFY CASEWORK PLAN SCALE: 1/4"=1'-0" 1. ALL DIMENSIONS ARE FINISHED DIMENSIONS (FINISHED FACE OF GWB OR CONCRETE) UNLESS OTHERWISE NOTED. 2. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. 3. THE GENERAL CONTRACTOR AND CASEWORK CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 4. THE CONTRACTOR SHALL PROVIDE NON-COMBUSTIBLE BLOCKING AT CASEWORK AND EQUIPMENT LOCATIONS AS REQUIRED. REFER TO PLANS, ELEVATIONS, SECTIONS, DETAIL DRAWINGS, NOTES, AND MANUFACTURER'S SPECIFICATIONS. 5. ALL CONCRETE PATCHING MUST BE LEVEL AND FLUSH WITH EXISTING CONCRETE FLOOR. PROVIDE CLASS 2A FIRE EXTINGUISHER WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR AND ADDITIONAL FIRE EXTINGUISHERS AS REQUIRED BY THE BUILDING OR FIRE DEPARTMENT INSPECTOR. F.E. - FIRE EXTINGUISHER F.E.C. - FIRE EXTINGUISHER CABINET (RECESSED) 7. REMOVE ALL EXISTING FLOOR COVERINGS, CASEWORKS, FIXTURES, WALLS, SOFFITS, CEILING TILES, CEILING GRIDS, ETC., NOT SHOWN ON NEW FLOOR/CEILING PLANS. PIPES, DEVICES AND ALL ASSOCIATED CONDUITS AND WIRES TO BE REMOVED MUST BE DISMANTLED BACK TO POINT OF ORIGIN. PATCH AND REPAIR AS REQUIRED TO MATCH ADJACENT EXISTING CONDITIONS AND FINISHES. EXTEND MALL BORDER TILE TO TENANT'S ENTRY DOORS AS SHOWN - ALIGN NEW TILE W/ EXISTING GROUT LINES. G.C. TO OBTAIN MALL TILE FROM MALL MANAGEMENT AT TENANT'S G.C.'S EXPENSE. 10. SEE SHEET A6.1 FOR ROOM FINISH AND DOOR SCHEDULES, DOOR AND PARTITION TYPES, AND FINISH MATERIALS. WALL LEGEND EXISTING PARTITION NEW PARTITION C LETTER INDICATES PARTITION TYPE bil00371 RECEIVED CITY OF TUKWILA DEC 18 :2013 PERMIT CENTER MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 REGISTERED ARCHITECT // S SEPH K. SHING STATE OF WASHINGTON TALUS CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS NO. DATE DESCRIPTION DATE: SCALE: DRAWN: CHECKED: PROJECT NO.: 12/17/2013 1/4"=r-0" AR JS PERMIT ISSUE DRAWING TITLE: FLOOR PLAN AND CASEWORK PLAN SHEET NO.: A2.1 EXISTING CEILING F(E) O F(E) Q F(E) H H H H H _H H 1 H H H H H H K p DISPLAY LIGHTS IN LINE OF CASEWORK2 BELOW CASEWORK, TYP. LINE OF CASEWORK BELOW JI LOPEN � • ABOVE .2 D. HI JI 3'L. DISPLAY LIGHTS IN CASEWORK, TYP.I D: . LINE OF CASEWORK NOTE: H 1 I J I BELOW ALL DISPLAY LIGHTS TO BE CENTERED IN.1. OPENS ABOVE H 3'L.CASEWORK DISPLAY LIGHTS IN CASEWORK, TYP. LINE OF CASEWORK BELOW JI in H H H H H H H EXISTING CEILING REFLECTED CEILING PLAN at LOW CEILING SCALE: 1/4"=1'-0" 0 I----- LINE OF EXISTING MALL FASCIA ABOVE LED LIGHT POWER/DATA AT CASEWORK BELOW GLAZING 5/8" GWB SOFFIT ON 4" x 16 GA. METAL STUDS 16" O.C. GLAZING POWER/DATA AT CASEWORK BELOW LED LIGHT 0 SEE REFLECTED CEILING PLAN AT LOW CEILING .44 w exisr. cr m ♦♦ B B B V • • O D • AL..4.40 k. 4.484444**D. .„ B B B B B B tet4 4B B A LeA \. 0 LJ ri LJ L CREFLECTED CEILING PLAN at HIGH CEILING 2 SCALE: 1/4"=1'-0" NEW 2'x2' ACT CEILING TILE WITH TEGULAR EDGE/REVEAL 'ARMSTRONG' FINE FISSURED SECOND LOOK, 6"x6" SQUARES TO MATCH EXISTING EXISTING 2'x2' ACT CEILING TILE WITH TEGULAR EDGE/REVEAL 'ARMSTRONG' FINE FISSURED SECOND LOOK, 6"x6" SQUARES 0 LINE OF EXISTING MALL FASCIA ABOVE GLAZING PROVIDE J -BOX FOR SIGNAGE, 20A EACH, COORDINATE SIGNAGE INSTALLATION WITH SIGNAGE CONTRACTOR 5/8" GWB SOFFIT ON 4"x 16 GA. METAL STUDS 16" O.C. GLAZING EXTEND ACT TO NEW SOFFIT REVIEWED FOR CODE COMPLIANCE APPROVED JAN 31 2014 City of Tukwila BUILDING DIVISION 4` CEILING—ROTES 1. COORDINATE CEILING GRID WITH HVAC DIFFUSERS. LIGHT FIXTURES, FIRE ALARM SYSTEM AND SPEAKERS. 2. EXIT SIGNS AND ILLUMINATION SHALL BE IN ACCORDANCE WITH LOCAL BUILDING CODE. 3. CONVENIENCE OUTLETS AT +18" AFF UNLESS OTHERWISE NOTED. 4. EXTERIOR SIGNAGE & LIGHTING TO BE CONTROLLED BY A 24HR. TIME CLOCK AT ELECTRICAL PANEL. TIME CLOCK TO BE SET ACCORDING TO OWNER'S SPECIFICATIONS. LIGHTING LEGEND ITEM DESCRIPTION A LOW VOLTAGE LIGHT TRACK, JUNO TRAC 12/25 W/ REMOTE TRANSFORMER, PENDANT MOUNT W/ SS CABLE HANGERS B TRAC 12 SPOTLIGHT, JUNO TL252L, 3000K, 13W C 2'x2', 2 -TUBE FLUORESCENT FIXTURE, 17W (NEW FIXTURE TO MATCH EXISTING) D RECESSED DOWNLIGHT, JUNO #CV6-132T-600C, 6" CLEAR, 32W TRIPLE -TUBE CFL COMPACT FLUORESCENT, 3000K F 4', 1 -TUBE FLUORESCENT FIXTURE, 32W (EXISTING TO REMAIN) G RECESSED DOWNLIGHT, JUNO #CV6-132T-600C, 6" CLEAR, 32W TRIPLE -TUBE CFL COMPACT FLUORESCENT, 3000K H FLUORESCENT STRIP AT PERIMETER DISPLAY WALL: LITHONIA LIGHTING #C125 120 ES, T8, 3000K ENERGY SAVING BALLAST (INSTALLATION TO BE COORDINATED WI CASEWORK CONTRACTOR) J 39" W/ #4 SHIELD LAMP STRIP FIXTURE INSIDE DISPLAY CASES: JUNO-DANALITE #FS -4-39-B, 3000K (INSTALLATION TO BE COORDINATED W/ CASEWORK CONTRACTOR) K LINEAR LED AT DISPLAY WINDOW: ANTARES ENTERPRISES BELLATRIX STRIP LIGHT, 3000K (INSTALLATION TO BE COORDINATED W/ CASEWORK CONTRACTOR) (E) INDICATES EXISTING p ( 3-- 0 37 9 RECEIVED CITY OF TUKWILA DEC 18 2013 PERMIT CENTER MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 REGISTERED ARCHITECT •SEPH K. SHINE STATE OF WASHINGTON TALUS CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS NO. DATE DESCRIPTION DATE: SCALE: DRAWN: CHECKED: PROJECT NO.: 12/17/2013 1/4"=V-0" AR JS PERMIT ISSUE DRAWING TITLE: REFLECTED CEILING PLANS SHEET NO.: A2.2 (.o �-SIGNBAND BEYOND DISPLAY CASE SEE DET. 5/A3.1 FOR BACKWALL ELEVATION - COUNTER ir DISPLAY CASE GATE CV 19"D. SHELF DRAWER GWB SOFFIT ENTRY GLASS DOORS Ce w 0 11 Q 4'-0" 4'-0" 4'-0" 4'-0" 3'-0" 7'-0" 4'-0" 4'-0" C41 INTERIOR ELEVATION SCALE: 1 /4"=1'-0" SCALE: 1/4"=1'-0" LIGHT SIGNBAND \- ACT CEILING ARTWORK, N.I.C. GLASS SHELVES 2'-0 EXISTING MALL FASCIA: PATCH & PAINT TO MATCH MALL CONCOURSE -k INCLUDNG BOTTOM OF SOFFIT GLAZING \/ /IN 4'-0" 1 4'-0" 1 4'-0" LIGHT HOT ROLLED STEEL FINISH GLAZING o� 0 0 (0 4'-0" i AN GLASS SHELVES IN A C w T L 1 -SP N N 4'-0" 4'-0" 3'-6" 3'- 6" 4'-0" 4'-0" 2'-0" INTERIOR ELEVATION SCALE: 1/4"=1'-0" 4'-1" 4'-1 I LO DISPLAY CASE 10 T T EXISTING MALL FASCIA: PATCH & PAINT TO MATCH ADJACENT BULKHEAD INCLUDNG BOTTOM OF SOFFIT 'TALLS' SIGN 'CAMERA' SIGN GLAZING BEYOND HOT ROLLED FINISH BEYOND EXISTING MALL FASCIA: PATCH & PAINT TO MATCH ADJACENT BULKHEAD INCLUDNG BOTTOM OF SOFFIT GLAZING HOT ROLLED STEEL FINISH PROVIDE EDGING ON SLAT WALL GLAZING DISPLAY CASE EXIST. COLUMN ACT CEILING EXIST. COLUMN EXIST. COLUMN r. SIGN BAND i-Azt -D1=SPLA PROVIDE EDGING ON SLAT WALL DISPLAY / CASE �( CD 4,-8„ 4'- 0" 4'-0" 4'-0" 4'-0" 4'-O" ± 1' 4,-O,, 4'- 0" 4'-0" ± 3'- 2" 3'-0" 12'-0" 3'-0" (6) INTERIOR ELEVATION SCALE: 1/4"=1 '-0" REV OWED FOR CODE COMPLIANCE APPROVED JO 31 2014 City of Tutivile F.Uit,OiNG DNISI 0 r 0 CV \ ACT CEILING \- SIGNBAND BEYOND -- SEE DET. 3/A3.1 FOR BACKWALL ELEVATION - COUNTER BEYOND C 2'-0" ±1O'-1" 2'-0" 5'-0" INTERIOR ELEVATION SCALE: 1/4"= 1 '-0" ACT CEILING �- SIGNBAND BEYOND SEE DET. 3/A3.1 FOR BACKWALL ELEVATION - ye- / DISPLAY CASE rr CDa) EQ. EQ. EQ. -0" 3'-0" 2-0" INTERIOR ELEVATION SCALE: 1/4"=1'-0" \ ACT CEILING SIGNBAND- EXIST. GLASS COLUMN SHELVES EXIST/. DOOR EQ. EQ. EQ. INTERIOR ELEVATION SCALE: 1/4"=1'-0" 1s13--0379 RECEIVED CITY OF TUKWILA DEC 1 8 , 2013 PERMIT CENTER MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 REGISTERED ARCHITECT SEPH K. SHING STATE OF WASHINGTON TALUS CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS NO. DATE DESCRIPTION DATE: SCALE: DRAWN: CHECKED: PROJECT NO.: 12/17/2013 1/4"=r-0" AR JS PERMIT ISSUE DRAWING TITLE: INTERIOR ELEVATIONS SHEET NO.: A3.1 15'-8" (EXIST. - VERIFY) v P LINE OF STRUCTURE GWB SOFFIT OUTLINE OF MALL NEUTRAL STRIP BEHIND 1/2" TEMPERED GLASS BEYOND WALL BEYOND OUTLINE OF CASEWORK IN FOREFRONT C DISPLAY CASE GWB WALL EQ. GLASS DOORS 6'-6" DISPLAY CASE • • • ,/ GWB WALL EQ. 20'-0" 3 LINE OF STRUCTURE LEASE LINE STOREFRONT BACK ELEVATION SCALE: 3/8"=1'-0" OUTLINE OF DISPLAY LIGHT —1 I I PATCH & PAINT ACT CEI G 4"x 20 GA. METAL STUDS © 16" O.C. W/ 5/8" GWB, BOTH SIDES P -LAM. ON 3/4" PLYWOOD ON 5/8" GWB 4"x 16 GA. METAL STUDS W/ 5/8" GWB 12" O.C., PAINT METAL BASE REMOVE PORTION OF EXIST. FASCIA 4"x10" FIRE -TREATED WOOD HEADER LINE OF GWB SOFFIT BEYOND OUTLINE OF MALL FASCIA BEHIND ACT CEILING OUTLINE OF MALL NEUTRAL STRIP BEHIND 1/2" TEMPERED GLASS BEYOND WALL BEYOND OUTLINE OF CASEWORK IN FOREFRONT METAL BASE, TYP. EXIST. MALL FASCIA PATCH AND PAINT DRYWALL BUILD -OUT GLAZING 5/8" GWB AROUND HEADER W/ HOT ROLLED STEEL FINISH AT STOREFRONT DISPLAY CASE 4 SECTION at DISPLAY CASE SCALE: 3/4"=l'-0" r. GLAZING HOT ROLLED STEEL FINISH SIGNAGE BY SIGNAGE CONTRACTOR (CLASS B, PER IBC SECT. 402.6.4) J PATCH & PAINT TO MATCH MALL FASCIA LINE OF STRUCTURE LEASE LINE STOREFRONT ELEVATION SCALE: 3/8"=1'-0" 4"x10" FIRE -TREATED WOOD HEADER r -i EXIST. MALL FASCIA PATCH AND PAINT DRYWALL BUILD -OUT HOT ROLLED STEEL FINISH 'TALLS' SIGN 4"x 20 GA. METAL STUDS © 16" O.C. W/ 5/8" GWB, BOTH SIDES 4"x 20 GA. METAL STUDS © 16" O.C. W/ 5/8" GWB, BOTH SIDES 'CAMERA' SIGN LU in ENTRY DOUBLE GLASS DOORS SECTION at ENTRY DOORS SCALE: 3/4"=1'-0" GLAZING BEYOND HOT ROLLED STEEL FINISH BEYOND IFY D iEWED FOR CODE COMPLIANCE APPROVED JAN 31 2014 r City of Tukwila ILDING DIVISION 13-037 RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 ioi REGISTERED ARCHITECT i SEPH K. SHING STATE OF WASHINGTON TALUS CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS DATE: SCALE: DRAWN: CHECKED: PROJECT NO.: 12/17/2013 AS NOTED AR JS PERMIT ISSUE DRAWING TITLE: STOREFRONT ELEVATIONS AND WALL SECTIONS SHEET NO.: A3.2 i 15'-8" (EXIST. - VERIFY) EXISTING MALL FASCIA - MALL - - NEUTRAL STRIP WITH 1/2" VERTICAL REVEAL ON TENANT SIDE, TYP. BOTH SIDES r. 1 ,� 1 �- o o HOT ROLLED STEEL - MET L FI ISH HOT ROLLED STEEL \ / 1/2" TEMPERED GLASS, TYP. BOTH SIDES ° ° DISPLAY WINDOW • DISPLAY WINDOW I SLOT W/ ACRYLIC PANE FOR LED LIGHT BEHIND, TYP. BOTH SIDES ' J \ / '-81 1/8" HOT ROLLEE STEEL W/ BOLTS, TYP. BOTH SIDES FLOOR LINE r. ° ° ° EN Y D RS ° ° o 6-- 1'-6" DOUBLE GLASS PIVOT DOORS 6'-6" 1 6" - TENANT ADDRESS: 1/2"W. x 4"H. W/ SIDELIGHTS S.S. GLASS CLAMPS, 20'-0" (3 PLCS.) EACH SIDE - WHITE VINYL, VER SIZE & LOCATION WITH T.C. IN FIEL LINE OF STRUCTURE LEASE LINE STOREFRONT ELEVATION SCALE: 3/8"=1'-0" 4"x10" FIRE -TREATED WOOD HEADER r -i EXIST. MALL FASCIA PATCH AND PAINT DRYWALL BUILD -OUT HOT ROLLED STEEL FINISH 'TALLS' SIGN 4"x 20 GA. METAL STUDS © 16" O.C. W/ 5/8" GWB, BOTH SIDES 4"x 20 GA. METAL STUDS © 16" O.C. W/ 5/8" GWB, BOTH SIDES 'CAMERA' SIGN LU in ENTRY DOUBLE GLASS DOORS SECTION at ENTRY DOORS SCALE: 3/4"=1'-0" GLAZING BEYOND HOT ROLLED STEEL FINISH BEYOND IFY D iEWED FOR CODE COMPLIANCE APPROVED JAN 31 2014 r City of Tukwila ILDING DIVISION 13-037 RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 ioi REGISTERED ARCHITECT i SEPH K. SHING STATE OF WASHINGTON TALUS CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS DATE: SCALE: DRAWN: CHECKED: PROJECT NO.: 12/17/2013 AS NOTED AR JS PERMIT ISSUE DRAWING TITLE: STOREFRONT ELEVATIONS AND WALL SECTIONS SHEET NO.: A3.2 MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 o REGISTERED ARCHITECT �SEPH K. SHING STATE OF WASHINGTON TALUS CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS NO. DATE DESCRIPTION DATE: 12/17/2013 SCALE: AS NOTED DRAWN: AR CHECKED: JS PROJECT NO.: PERMIT ISSUE DRAWING TITLE: INTERIOR DETAILS SHEET NO.: A4.1 SCHLUTER SYSTEM: GROUT "SCHIENE-E" SERIES NOTE: FLOOR FINISH PER SCHEDULE IN EACH ORTHOGONAL 12 GA. WIRE © 4'-0" O.C. FLOOR FINISH PER SCHEDULE HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SPACER BAR OR OTHER SHALL BE ATTACHED TO THE SYSTEM TO KEEP CLOSURE ANGLE. THE OTHER PERIMETER COMPONENTS a a ° a s a a Q END IN EACH HORIZONTAL DIRECTION SHALL HAVE A 3/4" g" MAX FROM SPREADING APART a a CLEARANCE FROM THE WALL ' AND SHALL REST UPON AND 3✓4„ BE FREE TO SLIDE ON THE ' 6 ±10° MAX MASTIC THIN SET AT ( ) TILE FLOOR WHERE OCCURS CLOSURE ANGLE 1 1 �\ 1 IM In ® MNl CONC SUB-FLOOR 2" 2" FLANGE, OVERS ZE NOTE: MIN SPRINKLER ESCUTCHEON FOR FLUSH FINISH, FEATHER UP OR DOWN AS REQD.; ACT CEILING WHERE ADJOINING SURFACE IS TILE, PROVIDE GROUT SEISMIC WALL MOLDING -' BETWEEN SCHLUTER & TILE. WALL LINE TRANSITION DETAIL _ ACT EDGE DETAIL 0 SCALE: 6"=1'-0" REVIEWED FOR SCALE: 3"=1'-0" COMPLIANCE ASCE 13.5.6.2.2 SEISMIC DESIGN CATEGORIES D THROUGH F: CODE APPROVED SAN 3 1 2014 LIGHTBOX FOR LED SUSPENDED CEILINGS IN SEISMIC DESIGN CATEGORIES D, E, AND F SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ASTM C635, ASTM C636, AND THE CISCA FOR SEISMIC ZONES 3-4 AS MODIFIED BY THE FOLLOWING: = LIGHT FIXTURE City ofTukmila BUILDING DIVISION' a. A HEAVY DUTY T-BAR GRID SYSTEM SHALL BE USED. SLOT HOLE WI b. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS Ill �� I ACRYLIC COVER FOR LED LIGHT f , £_ k`` PJ1 THAN 2.0 IN. (.50 MM). IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE A 0.75 IN. (19 MM) CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE ANGLE. ift SCHEDULED WALL . ` c. FOR CEILING AREAS EXCEEDING 1,000 SQ. FT. (92.9 SQ. M.), HORIZONTAL RESTRAINT - 1/2" W/ HOT ROLLED STEEL FINISH City of aiuhvvala -UIL.D11 G DIVISION OF THE CEILING TO THE STRUCTURAL SYSTEM SHALL BE PROVIDED. THE TRIBUTARY AREAS OF THE HORIZONTAL RESTRAINTS SHALL BE APPROXIMATELY EQUAL. EXCEPTION: RIGID BRACES ARE PERMITTED TO BE USED INSTEAD OF DIAGONAL SPLAY WIRES. BRACES AND ATTACHMENTS TO THE STRUCTURAL SYSTEM ABOVE SHALL BE TO LIMIT RELATIVE LATERAL DEFLECTIONS AT POINT OF ATTACHMENT OF ADEQUATE FOR PRESCRIBED IN SECTION '>.<-1- �; CEILING GRID TO LESS THAN 0.25 IN. (6 MM) THE LOADS 13.3.1. 3" 1/2"x1/2" ALUMINUM REVEAL, CLEAR ANODIZED MALL NEUTRAL PIER, d. FOR CEILING AREAS EXCEEDING 2,500 SQ. FT. (232 SQ. M), A SEISMIC SEPARATION JOINT OR FULL HEIGHT PARTITION THAT BREAKS THE CEILING UP INTO AREAS NOT EXCEEDING 2,500 SQ. FT. SHALL BE PROVIDED UNLESS STRUCTURAL ANALYSES ARE VERIFY WI TENANT COORDINATOR PERFORMED OF THE CEILING BRACING SYSTEM FOR THE PRESCRIBED SEISMIC FORCES THAT DEMONSTRATE CEILING SYSTEM PENETRATIONS AND CLOSURE ANGLES PROVIDE SUFFICIENT CLEARANCE TO ACCOMMODATE THE ANTICIPATED LATERAL DISPLACEMENT. EACH AREA SHALL BE PROVIDED WITH CLOSURE ANGLES IN ACCORDANCE WITH ITEM 2 WALL REVEAL DETAIL L�. AND HORIZONTAL RESTRAINTS OR BRACING IN ACCORDANCE WITH ITEM 3. e. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTIONS, SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2 IN. (50 MM) OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1 IN. (25 MM) IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1 IN. (25 MM) OF CEILING MOVEMENT IN ALL IS PERMITTED TO BE PROVIDED AT THE TOP OF THE SCALE: 3"=1'-0" HORIZONTAL DIRECTIONS SPRINKLER HEAD EXTENSION. f. CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING. g. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING. h. SUSPENDED CEILINGS SHALL BE SUBJECT TO THE SPECIAL INSPECTION REQUIREMENTS OF SECTION 11A.1.3.9 OF THIS STANDARD. NOTE: SUSPENDED CEILINGS SHALL BE BRACED AGAINST IN THE ABSENCE OF AN ENGINEERED DESIGN, REQUIRED: FOUR NO. 12 GA STEEL WIRES 2 INCHES OF A CROSS RUNNER. THE WIRES OTHER AND RUN UP TO BE ATTACHED TO STRUCTURE 45 DEGREES FROM THE HORIZONTAL. A COMPRESSION MAIN RUNNER AT THE ATTACHMENT OF THE STRUCTURE ABOVE. SUCH BRACING SYSTEMS EXCEED 12 FEET IN BOTH DIRECTIONS, BEGINNING FROM WALLS. LIGHT FIXTURES SHALL BE SUSPENDED STANDARDS. LIGHTING FIXTURES WHICH WEIGH TO THE CEILING GRID SYSTEM AND TO BUILDING GAGE WIRES. LIGHT FIXTURES WHICH WEIGH FROM THE STRUCTURE INDEPENDENT OF THE SHALL BE SUBMITTED TO SUBSTANTIATE THE EQUIPMENT SHALL BE SUPPORTED INDEPENDENT SUSPENDED CEILINGS SHALL COMPLY WITH TO SHALL WIRES ASCE LATERAL MOVEMENT DUE TO EARTHQUAKE. THE FOLLOWING BRACING SYSTEM WILL BE BE ATTACHED TO A MAIN RUNNER WITHIN SHALL BE SPLAYED 90 DEGREES TO EACH ABOVE AT AN ANGLE NOT TO EXCEED STRUT SHALL EXTEND FROM THE VERTICALLY AND BE ATTACHED TO THE SHALL BE PROVIDED AT A SPACING NOT TO AT A POINT NOT TO EXCEED 6 FEET IN ACCORDANCE WITH IBC LESS THAN 56 POUNDS SHALL BE ATTACHED STRUCTURE BY AT LEAST TWO NO. 12 56 POUNDS OR MORE SHALL BE SUSPENDED CEILING GRID, AND AN ENGINEERING DESIGN SUSPENSION SYSTEM. MECHANICAL OF THE CEILING SUSPENSION SYSTEM. 7-05. NO. 12 WIRE HANGER TO RIGID STRUCTURE STRUT ABOVE a 45 ►%-ems giN,NRUNNER SEISMIC BRACING - 2 is STRUCTURE ABOVE, o CRASS TEE DETAIL TYP. IST° 037 cr 1) RECEIVED CITY OF TUKWILA DEC 1 8, 2013 PERMIT CENTER SCALE: 3"=1'-0" MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 o REGISTERED ARCHITECT �SEPH K. SHING STATE OF WASHINGTON TALUS CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS NO. DATE DESCRIPTION DATE: 12/17/2013 SCALE: AS NOTED DRAWN: AR CHECKED: JS PROJECT NO.: PERMIT ISSUE DRAWING TITLE: INTERIOR DETAILS SHEET NO.: A4.1 1'-0 3/4" GROMMET P—LAM ON 3/4" PLYWOOD, PL -5 LIGHT FIXTURE 1/4" THICK GLASS SHELF, TYP. DRAWER Y 0 DUPLEX , OUTLET 0 0 0 0 0 Y P—LAM ON 3/4" PLYWOOD, PL -1 DOOR PULL P—LAM DOOR, PL— 2 P—LAM INTERIOR, PL -3 METAL BASE, MT -1 11 2'-0" SECTION at BACKWALL SCALE: 1 1/2"=1'-0" SLIDING DOORS, PL -2 N- OPEN SHELF, PL -2 1/4" GLASS TOP LIGHTING FIXTURE 1/4" GLASS FRONT DISPLAY SURFACE INTERIOR, PL -3 GROMMETED HOLE, 1 PER CABINET SALES AREA P—LAM FRONT, PL -1 METAL BASE, MT -1 2'— 0" ,, SECTION at DISPLAY CASE SCALE: 1 1/2"=1'-0" —0 3/4" GROMMET P—LAM ON 3/4" PLYWOOD, PL -5 LIGHT FIXTURE 1/4" THICK GLASS SHELF, TYP. SLATWALL, PL -4 DUPLEX ADJ. o OUTLET SHELF o Y 0 0 0 0 0 P -LAM ON 3/4" PLYWOOD, PL -1 DOOR PULL P—LAM DOOR, PL -1 P—LAM INTERIOR, PL -3 METAL BASE, MT -1 !1 2'-0" (1'-0" ® SIM.) SECTION at DISPLAY WALL SCALE: 1 1/2"=1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED JAN 31 2014 City of Tukwila BUILDING DIVISION 37 Cr RECEWED CITY OF TUKWILA DEC 18 2013 PERMIT CENTER MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 REGISTERED ARCHITECT SEPH K. SHING STATE OF WASHINGTON TALUS CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS NO. DATE DESCRIPTION DATE: SCALE: DRAWN: CHECKED: PROJECT NO.: 12/17/2013 AS NOTED AR JS PERMIT ISSUE DRAWING TITLE:. CASEWORK DETAILS SHEET NO.: A5.1 FINISH ROOM FINISH SCHEDULE WALLS -MATERIALS - INTERIOR PAINT CODE MANUFACTURER GENERAL LOCATION ACOUSTICAL CEILING TILE CODE MANUFACTURER GENERAL LOCATION ROOM NAME FLOOR BASE NORTH EAST SOUTH WEST CEILING REMARKS ENTRY/STOREFRONT *MALL MT - GL/MT GL/MT GL/MT GWB/PT 1, *2 SALES AREA CT MT GWB/PT GWB/PT - - (E)/ACT/GWB/ PT 1 SERVICE LIN MT - GWB/PT GWB/PT GWB/PT (E)/ACT/GWB/PT 1 PT -1 PRODUCT: COMMERCIAL GRADE PAINT CEILING MANUFACTURER: BENJAMIN MOORE NO.: 245 SHEEN: EGGSHELL SOURCE: BENJAMIN MOORE PHONE: 888.854.9889 PT -2 PRODUCT: COMMERCIAL GRADE PAINT ACCENT WALLS MANUFACTURER: BENJAMIN MOORE NO.: 112 COLOR: PEACH BRANDY SHEEN: EGGSHELL SOURCE: BENJAMIN MOORE PHONE: 888.854.9889 PT -3 PRODUCT: COMMERCIAL GRADE PAINT ACCENT SOFFITS MANUFACTURER: BENJAMIN MOORE NO.: 782 COLOR: BLUE BELLE SHEEN: EGGSHELL SOURCE: BENJAMIN MOORE PHONE: 888.854.9889 PT -4 PRODUCT: COMMERCIAL GRADE PAINT GENERAL WALLS MANUFACTURER: BENJAMIN MOORE NO.: HC -34 COLOR: WILMINGTON TAN SHEEN: EGGSHELL SOURCE: BENJAMIN MOORE PHONE: 888.854.9889 PT -5 PRODUCT: COMMERCIAL GRADE PAINT STOREFRONT FACADE MANUFACTURER: SHERWIN WILLIAMS NO.: 7048 COLOR: URBANE BRONZE FLOOR TILE CODE MANUFACTURER GENERAL LOCATION ACT -1 PRODUCT: NEW TILE TO MATCH EXISTING SALES/SERVICE DUNE SECOND LOOK MANUFACTURER: ARMSTRONG COLOR: 2X4 W/ 12"X12" SCORING GRID: 15/16" COLOR: FACTORY FINISH TO BE PAINTED PER DWGS SOURCE: ARMSTRONG, TIM HAMILTON PHONE: 800.448.1405 METAL CODE MANUFACTURER GENERAL LOCATION VESTIBULE (E) (E) (E) PT (E) PT (E) PT (E) PT (E) 1 STORE ROOM/EMPLOYEES (E) (E) (E) PT (E) PT (E) PT (E) PT (E) 1 ROOM FINISH LEGEND REMARKS FLOOR WALL 1. ALL PLUMBING, EQUIPMENT, MECHANICAL CT CERAMIC TILE MT METAL AND ELECTRICAL FIXTURES SHALL BE LIN LINOLEUM FLOORING PT PAINT PAINTED TO MATCH ADJACENT CEILING 2. EXTEND MALL BORDER TILE TO TENANT'S BASE CEILING ENTRY DOORS AS SHOWN - ALIGN NEW MT METAL BASE ACT ACOUSTICAL CEILING TILE TILE W/ EXISTING GROUT LINES. G.C. TO GWB 5/8 GWB SOFFIT OBTAIN MALL TILE FROM MALL MANAGEMENT AT TENANT'S G.C.'S EXPENSE. MT -1 PRODUCT: HOT ROLLED STEEL CASEWORK ACCENTS, ALLOY: STEEL FLOOR BASE AT SALES FINISH: HOT ROLLED AND SERVICE AREAS GAUGE: 16, 1/8" THICK FINISH COAT: CLEAR POWDERCOAT, SATIN OR PENETROL PLASTIC LAMINATE CODE MANUFACTURER GENERAL LOCATION DOOR SCHEDULE DOOR DOOR DESCRIPTION DOOR FRAME RATING REMARKS NO. TYPE MAT. FIN. MAT.. FIN. 1 A 6' 0" x 10'-0" (PAIR) AL/GL FF - - - 1, 2, 3 2 - EXISTING TO REMAIN (E) PT (E) PT 20 MIN. 3 - EXISTING TO REMAIN (E) PT (E) PT - PL -1 PRODUCT: PLASTIC LAMINATE CASEWORK EXTERIORS - PUBLIC SIDE, MANUFACTURER: FORMICA FACING AT EXISTING PLATFORMS COLOR: GINGER ROOT MAPLE NUMBER: 7288-58 FINISH: MATTE PL -2 PRODUCT: PLASTIC LAMINATE CASEWORK EXTERIORS - EMPLOYEE MANUFACTURER: FORMICA SIDE CASEWORK COUNTERTOPS COLOR: GRAPHITE NUMBER: 837-58 FINISH: MATTE2814 PL -3 PRODUCT: PLASTIC LAMINATE CASEWORK INTERIORS MANUFACTURER: FORMICA COLOR: NATURAL BIRCH NUMBER: 7481-58 FINISH: MATTE PL -4 PRODUCT: PLASTIC LAMINATE SLATWALL, TYP. MANUFACTURER: FORMICA COLOR: MDF SOLIDZ NUMBER: 7812-58 FINISH: MATTE PL -5 PRODUCT: PLASTIC LAMINATE CASEWORK VALANCE ABET LAM INATI COLOR: N/A NUMBER: 847 FINISH: MATTE REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 1 2014 City of Tukwila BUILDING DIVISION 4 - EXISTING TO REMAIN (E) PT (E) PT 20 MIN. REMARKS DOOR FINISH LEGEND 1. DOOR HARDWARE SHALL BE MOUNTED AL ALUMINUM BETWEEN 36" AND 48" ABOVE FINISHED FF FACTORY FINISH c.FOR FLOOR. GL GLASS OMPLIANce :. PT PAINT ' '"'WED 2. PIVOT DOORS LOCKED AT OPEN POSITION DURING BUSINESS HOURS. (E) INDICATES EXISTING 3. PIVOT DOORS WITH FLOOR LOCK AND Tukwila DOOR STOPS c_ DIVISION CT -1 PRODUCT: PORCELAIN FLOOR TILE SALES AREA MANUFACTURER: C & S DISTRIBUTORS STYLE: AREA SERIES COLOR: BRONZO PULPIS NUMBER: 707945 SIZES: 18" X 18" GROUT: HYDROMENT- SERIES, COLOR TAUPE H151 BASE: 4" X 18" BULLNOSE, NUMBER 707965 SOURCE: 800.663.6510S CERAMIC TILE DISTRIBUTORS, KRISTINA JOYCE PHONE: LINOLEUM CODE MANUFACTURER GENERAL LOCATION DOOR TYPE / 6'-6" 19 , DOOR NOTES 1. LOCATE ITEMS IN ACCORDANCE WITH NBHA LIN -1 PRODUCT: LINOLEUM FLOORING SERVICE MANUFACTURER: FORBO STYLE: FRESCO COLOR: WALNUT NUMBER: 3874 SIZES: T.B.D. SOURCE: FORBO PHONE: 800.842.7839 "RECOMMENDED LOCATIONS FOR BUILDERS HARDWARE", UNLESS OTHERWISE NOTED. / ALUM. 8"-10" RAIL, POWDER COATED, BLACK 2. TEST AND ADJUST HARDWARE FOR QUIET, / 3/4" TEMPERED, SMOOTH OPERATION, FREE OF STICKING, FRAMELESS, DOUBLE BINDING OR RATTLING. HARDWARE TO GLASS DOORS AND COMPLY WITH REQUIREMENTS OF ADA. SIDELIGHTS BY 'C.R. LAURENCE' OREUAL Q - - DOOR PULLS, POWDER COATED, BLACK / ALUM. CONTINUOUS RAIL, POWDER COATED, BLACK TYPE 'A' PARTITION TYPE 20 GA. DEEP LEG DEFLECTION TRACK (TO ALLOW FOR 1/2" DEFLECTION, MIN.) W/ HILTI X -DNI 0.1450 x 3/4" EMBED FASTENERS CO 16" O.C. 'I SECT LINE OF STRUCTURE I SEALANT 'X' PLAN MET. STUDS W/ 5/8" TYPE GWB, BOTH SIDES, W/ ACOUSTIC BATT INSULATION IN WALL CAVITIES, CONTINUOUS,pEUNLESS OTHERWISE ___,\„__7QTGi SECT . METAL TRACK W/ HILTI X -DNI 0.1450 x 3/4" EMBED FASTENERS CO 16" O.C., PROVIDE FLEXIBLE SEALANT, CONTINUOUS, UNDER RUNNER b 1 3•41%., 0 37cto BASE PER SCHEDULE I FLOOR LINE SPACING LIMITING O.C. HT. RECEIVED A 20 GA., 4" MET. STUDS 16" 16'-8" CITY OF TUKWILA DEC 1 8 ..2013 NOTE: METAL STUD IS INTERIOR NON-STRUCTURAL PERMIT CENTER NON -COMPOSITE TABLE (5 LBS/SF) FROM 'STEEL STUD MANUFACTURERS ASSOCIATION' INISM MESHERISHINGIMCNUTT 808 East Roy Street Seattle, WA 98102 206.622.4981 T 206.682.4289 F www.meshershingmcnutt.com 3745 REGISTERED ARCHITECT // J � d v� 'SEPH K. SHING STATE OF WASHINGTON TALUS CAMERA SOUTHCENTER MALL - SPACE F664 633 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS NO. DATE DESCRIPTION DATE: SCALE: DRAWN: CHECKED: PROJECT NO.: 12/17/2013 NONE AR JS PERMIT ISSUE DRAWING TITLE: ROOM FINISH SCHEDULE, DOOR SCHEDULE, DOOR AND PARTITION TYPES, FINISH MATERIALS SHEET NO.: A6.1