HomeMy WebLinkAboutPermit D13-043 - HOBERECHT RESIDENCE - NEW DETACHED GARAGEHOBERECHT
RESIDENCE
15605 44 AV S
D13-043
City otTukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
Parcel No.: 8108600130
Address: 15605 44 AV S TUKW
Suite No:
Project Name: HOBERECHT RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D13-043
Issue Date: 02/05/2013
Permit Expires On: 08/04/2013
Owner:
Name: HOBERECHT PAUL R
Address: 15605 47TH AVE S , TUKWILA WA 98188
Contact Person:
Name: PAUL HOBERECHT
Address: 15605 44 AVS , TUKVVILA WA 98188
Phone: 206 431-0133
Contractor:
Name: N/A PER BOB BENEDICTO - INSPECTIONS ONLY Phone:
Address:
Contractor License No: Expiration Date:
Lender:
Name:
Address:
DESCRIPTION OF WORK:
COMPLETE INSPECTIONS ON EXPIRED PERMIT (D03-156) AND ANY CORRECTIONS RELATED THERETO. ORIGINAL
SCOPE OF WORK WAS: CONSTRUCTION OF A 1,722 SQ FT ATTACHED GARAGE WITH A SECOND STORY ABOVE. PUBLIC
WORKS ACTIVITIES INCLUDED STORM DRAINAGE, SEPTIC TANK DECOMISSION AND LAND ALTERING
Value of Construction: $0.00 Fees Collected: $256.50
Type of Fire Protection: International Building Code Edition: 2009
Type of Construction: VB Occupancy per IBC: 0021
Electrical Service Provided by: SEATTLE CITY LIGHT
**continued on next page**
doc: IBC -7/10
D13-043 Printed: 02-05-2013
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Permit Center Authorized Signature:
I hereby certify that I have read an
governing this work will be compli
N
N
N
Number: 0 Size (Inches): 0
Start Time:
Volumes: Cut 0 c.y.
Start Time:
Private:
Profit: N
Private:
Date:
End Time:
Fill 0 c.y.
End Time:
Public:
Non -Profit: N
Public:
oc
13
ned this permit and know the same to be true and correct. All provisions of law and ordinances
, whether specified herein or not.
The granting of this permit does not pre
construction or ,erformance of work.
to this permit.
Signature:
Print Name:
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this development permit and agree to the conditions attached
zOJO Date: a s/ao 3
P6 U az ELL H
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification
showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service
for inspection at the factory.
5: All wood to remain in placed concrete shall be treated wood.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D13-043 Printed: 02-05-2013
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
10: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall
be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum
distance of 4 -inches shall be maintained above the controls with the strapping.
11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
14: ***PUBLIC WORKS DEPARTMENT CONDITIONS***
15: The applicant must notify the City Project Inspector at (206)433-0179 upon commencement and completion of work at least
24 hours in advance. All inspection requests for utility work must also be made 24 hours in advance.
16: Contractor shall notify Public Works Project Inspector at (206)433-0179 of commencement and completion of work at least
24 hours in advance.
17: Any material spilled onto any street shall be cleaned up immediately.
18: Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation
off-site or into existing drainage facilities.
19: From October 1 through April 30, cover any slopes and stockpiles that are 3H: IV or steeper and have a vertical rise of
10 feet or more and will be unworked for greater than 12 hours. During this time period, cover or mulch other disturbed
areas, if they will be unworked more than 2 days. Covered material must be stockpiled on site at the beginning of this
period. Inspect and maintain this stabilization weekly and immediately before, during and following storms.
20: From May 1 through September 30, inspect and maintain temporary erosion prevention and sediment at least monthly. All
disturbed areas of the site shall be permanently stabilized prior to final construction approval.
21: The site shall have permanent erosion control measures in place as soon as possible after final grading has been
completed and prior to the Final Inspection.
22: It is strongly recommended that storm drainage designs be certified by a licensed engineer. Otherwise, the owner
assumes liability for the design and any subsequent related damages.
23: Downspouts, driveway, patio and drainage from other impervious areas shall be collected in an on-site storm drain
system. Drains shall be 4" minimum diameter, PVC schedule 40 or corrugated poly ethylene pipe with a minimum 1% slope
for gravity discharge to location approved by the Public Works Department. Downspouts shall not connect to footing
drains. Footing drain and downspouts may share a single discharge pipe downstream of the lowest footing drain.
24: Any septic tanks in the area shall be pumped empty and removed or filled with sand. A copy of the documentation from
the business that performed the pumping shall be provided to the City Utilities Inspector.
doc: IBC -7/10
D13-043 Printed: 02-05-2013
CITY OF TUK LA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building Pe.it No.
Project No.
Date Application Accepted:
t)•127
Date Application Expires:
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: _ 0 Ls) Li AU E_ S
Tenant Name: Au L 4-10 E(2-8 M T
King Co Assessor's Tax No.:
9�n��—vl3o
Suite Number: Floor:
New Tenant: ❑ Yes ❑ .. No
PROPERTY OWNER
Name: PAUL uoBE12EC.NT
Address: j S (o O S LI A\ I E .S
City: U K W t, A State: w 4 Zip:ct 81 9i
City. ) u R W II,.pt,State: w A Zip: ct 6 t 8�
CONTACT PERSON — person receiving all project
communication
Name: pa u L 14, o B E IZEC.+-t T
Address: ) 500 S Li A V r -
City: U K W t, A State: w 4 Zip:ct 81 9i
Phone: a, co _ 931— o 13.'ax:
Email: PALIL 2 Oa,Q.,IA°TMra iz, t GdM
GENERAL CONTRACTOR INFORMATION
Company Name:
Address:
Company Name:
Address:
Architect Name:
City:
State:
Zip:
Phone:
Fax:
Phone:
Fax:
Contr Reg No.:
Email:
Exp Date:
Tukwila Business License No.:
H:\Applications\Forms-Applications On Line \2012 Applications\Permit Application Revised - 2-7-12. docx
Revised: February 2012
bh
ARCHITECT OF RECORD
Name:
Address:
Company Name:
Architect Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
ENGINEER OF RECORD
Name:
Address:
Company Name:
Engineer Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name:
Address:
City: State: Zip:
Page 1 of 4
Valuation of Project (contractor's bid price): $ Existing Building Valuation: $
Describe the scope of work (please provide detailed information): c. v -t L- TE //IS {PEC%1O,U S
EAPIR-E.o PE 1I7 DO3 ^1ST
Will there be new rack storage? I=1.... Yes
❑ ..No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square;Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? 0 Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Wppltcauons\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx
Revised: February 2012
bh
Page 2 of 4
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
lst Floor
2nd Floor
3rd, Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached. Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? 0 Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Wppltcauons\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx
Revised: February 2012
bh
Page 2 of 4
Scope of Work (please provide detailed information):
Call before you Dig: 811
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
❑ .. Tukwila 0 ...Water District #125
❑ .. Water Availability Provided
Sewer District
❑ .. Tukwila '
❑ .. Sewer Use Certificate
❑... Highline
❑...Valley View ❑... Renton
❑ ...Sewer Availability Provided
0... Renton
0... Seattle
Septic System:
0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with Application (mark boxes which apply):
❑ .. Civil Plans (Maximum Paper Size — 22" x 34")
❑ .. Technical Information Report (Storm Drainage)
❑ .. Bond 0...Insurance 0... Easement(s)
Proposed Activities (mark boxes that apply):
❑ .. Right-of-way Use - Nonprofit for less than 72 hours
❑ .. Right-of-way Use - No Disturbance
❑ .. Construction/Excavation/Fill - Right-of-way 0
Non Right-of-way 0
❑ .. Total Cut
❑ .. Total Fill
cubic yards
cubic yards
❑ .. Sanitary Side Sewer
❑ .. Cap or Remove Utilities
0 .. Frontage Improvements
❑ .. Traffic Control
0 .. Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑ .. Permanent Water Meter Size (1)
❑ .. Temporary Water Meter Size (1)
❑ .. Water Only Meter Size
0... Geotechnical Report
❑ ... Maintenance Agreement(s)
❑ .. Traffic Impact Analysis
❑ .. Hold Harmless — (SAO)
❑ .. Hold Harmless — (ROW)
0...Right-of-way Use - Profit for less than 72 hours
0...Right-of-way Use — Potential Disturbance
0...Work in Flood Zone
0...Storm Drainage
0...Abandon Septic Tank
❑...Curb Cut
0... Pavement Cut
0...Looped Fire Line
79
57
❑ .. Sewer Main Extension Public
❑ .. Water Main Extension Public
97
❑...Grease Interceptor
❑... Channelization
❑...Trench Excavation
❑... Utility Undergrounding
WO # (2) " WO # (3) " WO #
WO # (2) " WO # (3) " WO #
WO # ❑ .. Deduct Water Meter Size "
Private 0
Private 0
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
0 .. Water ❑ .. Sewer 0 .. Sewage Treatment
Monthly Service Billing to:
Name: Day Telephone:
Mailing Address:
City State Zip
Water Meter Refund/Billing:
Name:
Mailing Address:
Day Telephone:
City
State Zip
H:Wpplicauons\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx
Revised: February 2012
bh
Page 3 of 4
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OW
Signature:
1E OR AUT ZE AGENT:
Print Name:
l
A -UL No
Mailing Address: ) S , 0 -� L! L j 41/ E
H:\ApphcationsWorms-Applications On Line \2012 Applications\Permit Application Revised - 2-7-12.docx
Revised: February 2012
bh
Day Telephone:
TKw/Lfl
City
Date: c2 / 2,013
.2o6--7IS-8819
acl-S(
State Zip
Page 4 of 4
• 1
AUTHORIZATION FOR ALTERNATE PLAN
SUBMITTAL (LIMITED SCOPE OF WORK)
IBC & IRC Section 104.1
Date: OZ/05/20 {3
Address: I7&05 44-4100E �l
Description of Work:
:t► u •
NW?
Permit/Application Number: T)1 (�
Tukwila, WA 981
•
etLQieo— 0150
• 10M t 5
M04 ---W3/ Vo3- l 5Cp, 6,44D A4-19 cotzYz 'torl5 - 4 114- To,
The above project permit applicant, due to the limited scope of work, is authorized to submit reduced plan
requirements described below:
1. Complete permit application(s):
Building MMechanical ❑ Plumbing/Gas Piping ❑ Electrical ❑ Other
2. Plan and/or Specification (minimum):
❑ Site Plan ❑ Floor Plan ❑ Elevations ❑ Foundation ❑ Structural Calcs
❑ Cross Sections ❑ Roof Plan ❑ Narrative ❑ Narrative WSEC Compliance
F1
. Required Inspections (only completed when to be issued over the counter):
❑ Glazing ❑ Final Other: ) crF -t=S e 4/Nsp
❑ Framing
4. Other Special InstruTctions:
geo
/ca(l,, li-15UL
C-t.Rzt Ci
pJ1 jot_ '
l`,
M(r
-FINAL
I F\E,ps FutzrtAc - 4 OK RsTzw. &tto N)
'RLLg, Ft A-141.
Authorized By:
Printed Name:
Date: d05/2.013
(Authorization v days after date)
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 431-3670 • Fax: 206 431-3665
W:\Permit Center\Templates\Forms\Auth for Reduced Plan Submittal.docx
of Tukwila.
1
Department of Community Developm en t
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R13-00736
Initials: JEM
Payment Date: 02/05/2013
User ID: 1165 Total Payment: 319.50
Payee: PAUL R HOBERECHT
SET ID: S000001926 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member Amount
D13-043
M13-037
TOTAL:
256.50
63.00
256.50
TRANSACTION LIST:
Type Method Description Amount
Payment Check 6423 319.50
TOTAL: 319.50
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
MECHANICAL - RES
STATE BUILDING SURCHARGE
000.322.100
000.322.102.00.0
640.237.114
252.00
63.00
4.50
TOTAL: 319.50
.c.)` .
INSPECTION RECORD
Retain a copy with permit 12)13- oL,-,-1-----
INSPECTION NO. `, PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670.
Permit Inspection Request Line (206) 431-2451
Projlect:
>--1obe'(Lc-;ANT- ac's
Type of Inspection:
Cr1L!nl%_1n,$itIf(,Liz!N6-
Address:
15 (dJ 1-! a ra V `"-,
Date Called:
Special Instructions:
Date Wanted:.
_.z.5—)3
6
P.m.
Requester:
(-YOCN 6A-141/3
Phone No:
20(4/7IS_ S9/ i
Approved per applicable codes.
•
❑ Corrections required prior to approval.
COMMENTS:
d-
C9 LA 5-W 'N,
(-YOCN 6A-141/3
`
/J
i
.._-
spec (ori: `�-
Date:
SPECTION FEE REQUIRED. Prior to
id at 6300 Southcenter Blvd, Suite 100.
next inspection, fee must be
Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:"
clect.t
-
Type of Inspection:
Address:Date
I 4514° 5'`
1+4.e
Called:
2/ 4;71
3
Special Instructions:
Date Wanted:. i
if 6--nP.m.
a.m.
Requester: (�/�,
1"i�1
Phone No:L0 1-t1 _O11
Approved per applicable codes.
1 COMMENTS:
ElCorrections required prior to approval.
Inspector:
elk
Date: Z J,61
❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be