HomeMy WebLinkAboutPermit D13-047 - VAN UYEN / ALBRECHT RESIDENCE - REMODELVAN UYEN - ALBRECHT
RESIDENCE
11806 44 AV S
D13-047
City oOI'ukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
DEVELOPMENT PERMIT
Parcel No.: 3347401325
Address: 11806 44 AV S TUKW
Suite No:
Project Name: VAN UYEN - ALBRECHT RESIDENCE
Permit Number: D13-047
Issue Date: 03/19/2013
Permit Expires On: 09/15/2013
Owner:
Name: VAN UYEN NHI THI
Address: 4254 S 137TH PL , TUKWILA WA 98168
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: S K M CONSTRUCTION INC
Address: 14415 SE 143 PL , RENTON, WA 98059
Contractor License No: SKMCOI*052L3
Lender:
Name:
Address:
Phone: 206-296-7437
Phone: 425 235-5569
Expiration Date: 12/30/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $17,837.00 Fees Collected: $716.64
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
**continued on next page**
doc: IBC -7/10
D13-047 Printed: 03-19-2013
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
N
N
Number: 0 Size (Inches): 0
Start Time:
Volumes: Cut 0 c.y.
Start Time:
End Time:
Fill 0 c.y.
End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non -Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date: � i 3
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature: Sly f ► r 11 , Date: 3j n 1 1.2.
Print Name: lr:d _ ti' r r mi
this requirement.
•
7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D13-047 Printed: 03-19-2013
• •
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.citukwila.wa.us
Building Permit No. ( 0 z7
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: 11806 44th Ave S
Tenant Name: Nhi Thi Van Uyen and William Albrecht
Property Owners Name: Nhi Thi Van Uyen and William Albrecht
Mailing Address: 4254 S 137th PI
King Co Assessor's Tax No.: 3347401325
Suite Number: Floor:
New Tenant: 0 Yes ® ..No
Tukwila
WA
98168
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296-7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker@kingcounty.gov
City State
Fax Number: (206) 269-7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
Zip
Contact Person:
E -Mail Address:
Contractor Registration Number:
City
State
Day Telephone:
Fax Number:
Expiration Date:
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Jesse Holgate or Timothy Fenlason
E -Mail Address: jesse@smstemper.com/tfenlason@jonespayne.cm
City State
Day Telephone: (206) 624-2777
Fax Number: (206) 624-2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
H:\Applications\Fotms-Applications On Line\2009 Applications \1-2009 - Permit Application.doc
Revised: 1-2009
bh
City
Day Telephone:
Fax Number:
State
Zip
Page 1 of 6
• •
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price): $ 17,837 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
®.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? 0 Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
0 Sprinklers 0 Automatic Fire Alarm m None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTI_C SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Fonns-Applications On Line\2009 Applications \I-2009 - Permit Appltcanon.doc
Revised: 1-2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
Is' Floor
863
2"d Floor
3`d Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? 0 Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
0 Sprinklers 0 Automatic Fire Alarm m None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTI_C SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Fonns-Applications On Line\2009 Applications \I-2009 - Permit Appltcanon.doc
Revised: 1-2009
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not'exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNS ' ii ' AU /:- _
Print Name: - y J. Fenlason, SM Stemper Architects, PLLC Day Telephone: (206) 624-2777
Signature:
Date:
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
City
State
Zip
Date Application Accepted:
Date Application Expires:
Staff Initials:
H:\Applications\Fonns-Applications On Lme\2009 Applications\I-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 6 of 6
City oWukwilar
Departmental Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site. hip •/Avwwci tukwila.wa.us
SET RECEIPT
•
Copy Reprinted on 02-19-2013 at 09:09:21 02/19/2013
RECEIPT NO: R13-00837
Initials: WER
Payment Date: 02/19/2013
User ID: 1655 Total Payment: 5,833.28
Payee: PAMELA K KUEHL (BY PHONE)
SET ID: 020713 SET NAME: KING COUNTY SOUND ABATEMENT
SET TRANSACTIONS:
Set Member Amount
D13-045 811.18
D13-046 842.70
D13-047 716.64
D13-048 748.15
D13-049 622.10
D13-050 1,067.51
M13-038 167.70
M13-039 167.70
M13-040 167.70
M13-041 167.70
M13-042 167.70
M13-043 186.50
TOTAL: --7-1076/1
TRANSACTION LIST:
Type Method Description
Amount
Payment Credit C VISA 5,833.28
TOTAL: 5,833.28
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES 000.322.100 2,897.75
MECHANICAL - RES 000.322.102.00.0 1,025.00
PLAN CHECK - RES 000.345.830 1,883.53
STATE BUILDING SURCHARGE 640.237.114 -----2-77-01-01
TOTAL: 5,833.28
,INSPECTION RECORD
Retain a copy with permit
INSP CTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36701
Permit Inspection Request Line (206) 431-2451
.5i3-ct!47
Project:
t !Ad d tjLien/
/-e5 ,r
Typ of Inspection:
12-031-.
I`
-A ' NAL -
Address: 1
cli
Date Called: t
Special Instructions:
Z......- if
Date Wanted.
—
^ Gp.m.
•t.....r
Requester:
Phone No:
42.5--5
i-22.2'7
•
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
tit Lel°
iX A
lla
Date_ ;5„..>„....."
n REINSPECTION FEE RE UIRED' Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit,
..PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431.3670
Permit Inspection Request Line (206) 431-2451
Project:
Ty/p) a of In pection ; qtr A
Address: f i-2,
1 1 0 (a 44 _ / Ut-
Dat alled: ,!
i --,x ofd- ._ & .4'6
Special Instructions:
Date Wanted:. - a.m.
,.�.,,...(�. ,gip m
Requester:
i '
PhHy-. to ! ,212,7
ElApproved per applicable codes.
Corrections requiredprior to approval.
COMMENTS:
k(SIA--`�\Ai
Inspector/
Date:
n REINSPECTION FEE REQUIRED. Prior, to next inspection, fee must, be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedulereinspection.
Gale Contractor ServicesRECEIVED
A Masco Contractor Services Company CITY OF TUKWILA
16910 59th Ave. NE, Suite 100
Arlington, WA 98223 MAY 2 0 2013
Installed Insulation CertificatgERNIIT CENTER
"We certify that insulation material listed here and installed at the following residence
surrounding conditioned space meet applicable federal, state, and local specifications."
Address or Lot Number 11806 44th Ave S.
•
PEW CO D C Y
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: D13-047 DATE: 02-07-13
PROJECT NAME:. VAN'`UYEN-ALBRECHT RESIDENCE
SITE ADDRESS: 11806 44 AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Issued
DEPART ENTS:�
#dinMn
Public Works ❑
r3
Fire Prevention
Planning Division
Structural ❑ Permit Coordinator IP
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
n
DUE DATE: 02-12-13
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
TUES/THURS ROUTING:
Please Route
Structural Review Required ❑ No further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 03-12-13
Not Approved (attach comments) ❑
DATE:
Permit Center Use Only 1:
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Documents/routing slip.doc
2-28-02
Contractors or Tradespeople Pier Friendly Page
•
General/Specialty Contractor
A business registered as a construction contractor with Lal to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name S K M CONSTRUCTION INC UBI No. 601577401
Phone 4252355569 Status Active
Address 14415 Se 143Rd Pt License No. SKMCOI'052L3
Suite/Apt. License Type Construction Contractor
City Renton Effective Date 6/23/1995
State WA Expiration Date 12/30/2013
Zip 98059 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
ther Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
SKMC0 093L6
S K M
CONSTRUCTION
Construction
Contractor
General
Unused
6/26/1991
6/17/1995
Archived
SKMINI'976QL
S K M INDUSTRIES
INC
Construction
Contractor
General
Unused
11/13/2003
12/6/2009
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
MORRISON, SHEILA K
President
06/23/1995
Bond Amount
MARKET SANDERS
Agent
06/23/1995
06/25/2001
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
5
FIRST NATL INS CO OF
AMERICA
6695979
06/17/2010
Until Cancelled
$12,000.00
04/26/2010
4
DEVELOPERS SURETY
a INDEM CO
188889C
12/30/2001
Until Cancelled
08/01/2010
$12,000.00
12/05/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
16
James River Ins
Co
000495931
08/21/2012
08/21/2013
$1,000,000.00
08/20/2012
15
James River Ins
00049593
08/21/2011
08/21/2012
$1,000,000.0008/18/2011
14
COLONY INS CO
EPK300402
08/21/2010
08/21/2011
$1,000,000.00
08/20/2010
13
CENTURY
SURETY CO
CCP616634
08/21/2009
08/21/2010
$1,000,000.00
01/20/2010
12
AMERICAN
STATES INS CO
01CH6810051
01/25/2009
01/25/2010
$1,000,000.00
01/23/2009
11
AMERICAN
STATES INS CO
01CH6810051
12/30/2008
01/25/2009
$1,000,000.00
12/23/2008
10
AMERICAN
STATES INS CO
01CH6810051
12/30/2007
12/30/2008
$1,000,000.00
12/07/2007
9
AMERICAN
STATES INS CO
01CD87273820
12/30/2006
12/30/2007
$1,000,000.00
12/19/2006
httnsl/fortress.wa.gov/lni/bbin/Print asnx
03/19/2013
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - 000784012 BID PACKAGE M-37
3-53-0058-045
SCOPE OF WORK
RENOVATION or RESIDENCE TO REDUCE NOISE INFILTRATION OF AINOISE AND PROVIDE
MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND
SPECIFICATIONS INCLUDING IBUT NOT LIMITED TO:
APPLICABLERCRAFT
YES NO
1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS LIJITI-I NEU1 VINYL -FRAMED ACOUSTICAL WINDOWS.
X
2. CUT DOW OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS.
X
3. WILL OF EXISTING OPENINGS.
X
4. SELECTIVE REPLACEMENT OF NTERIOR / EXTERIOR DOORS WITI-I NEW ACOUSTICAL DOORS.
X
5. INSTALLATION OF STORM DOORS.
X
6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS,
X
I INSTALLATION OF SECONDARY SKYLIGHTS.
X
8. INSTALLATION OF PET DOORS.
X
5. INSTALLATION OF FIREPLACE FRESH AIR VENT.
X
10. INSTALLATION OF CHIMNEY CAP.
X
11. REGULATED MATERIALS ABATEMENT.
X
12. ATTIC VENT BAFFLES.
X
13. INSTALLATION OF ATTIC INSULATION.
X
14. INSTALLATION OF MECHANICAL VENTILATION EQU1FMENT, BLENDING At UNIT AND
ASSOCIATED DUCTING.
X
15. INSTALLATION OF MECHANICAL VENTILATION EQUIFMENT, FURNACE MODIFICATION AND
ASSOCIATED DUCTING.
X
16. ARCHITECTURAL MODIFICATIONS TO SUPPORT NSTALLATION OF MECHANICAL VENTILATION.
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCI-IITECTURAL MOD IF ICAT IONS.
X
1B. INSTALLATION OF SMOKE: DETECTORS.
X
15. NEW ELECTRICAL PANEL. / SERVICE.
X
20. KNOB AND TUBE UJIRING.
X
FI V1PY,
Permit No. V OKI
ph' fr.,43w approval is subject to errors and omissions.
o construction documents does not authcriza
IL: i1:on oi any adopted code or ordinance. Recelpt
L,,J;J:.oieci cid Copy and conditions is acknowledged:
By
Date*
City OfTUkwIIa
BUILDING DIVISION
REVIS;ONS
No ch,77.n,ccs shall bo mr!do to the cope
c ,,,.7.;,!( without prior approv7)1 ot
Building Division.
1777: ricv::3ais Mil require a ne!i sullmittel
c.:. may ftif udo cdd ional pan revic‘-v
i''.Z.OUIRE.'D FOR:
EiOriechanical
ritiectrical
Err iumbing
Cis Piping
c.j of Tukwila
DiV1SION
SITE AND BUILDI
NG INFORMATION
JuRtsoICTION:
Department of Planning and Development
city or Seattle, WA
APPLICABLE CODE&
2005 International Residential Code,
International Fire Code,
International Mechanical Code
ZONING: SFI200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Charge)
v S NON SPRINKLEIeED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 1 4 Inv)
A-7 vv.
City of Tukwila
BUILDING DIVISION
3341401325
LEGAL DESCRIPTION:
LOT D, BLOCK 5 HILLMAN'S MEADOW GARDENS ADDITION TO THE crry OF SEATTLE DIVISION NO. 01 ACCOROING TO
TI -IE PLATS THERE OF RECORDED IN THE VOLUME 12 OF PLATS, PAGE(6) 64 RECORD OF KING COUNTY, WASWINGTON.
SITUATED IN THE COUNTY OF KING, STATE Of WASHINGTON.
DRAWING INDEX
100
A10
42.0
42.1
422
42.3
TITLE SHEET, FROJECT INFO.
FLOOR PLANS 4 NOTES
WINDOW TYPE& SCHEDULE 4 DETAILS
POOR TYPES, SCI-IEDULE 4 DETAILS
MISCELLANEOUS DETAILS
WINDOW FLASHING DETAILS
MID LEGEND& SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX
M2.0 MECHANICAL PLANS ANP DETAILS
E1.0 ELECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING =NIT INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 58108
Ph 206. 263. 9233
FAX: 206. 256. 0190
Contact: Sharvn Parker
E-mail: Sharyn.Parkerekingcounty.gov
ARCI4ITECT:
S.M. Stomper Architects P.L1...C.
4000 Delridge Way SW, Suite 200
Seattle, WA 98106
Ph 206, 624. 2111
Fax 206. 624. 2913
Contact: Jerry Osborn, Melody Leung
E-mail: Jerryesmsternper.com
melodyesmstemper.corn
ACOUSTICAL ENGINEER:
55A Acoustics
222 Etruria Street, Suite 100
Seattle WA 58105
Pl 206. 535. 0815
Fax: 206. 635. 0E324
Contact: Mohamed Alt Allaoua
ELECTRICAL ENGINEER:
Tree West Engineers
2102 & 42nd Street, Suite 301
Tacoma, WA 58405
Ph 253, 412. 3300
Fax: 253. 412. 3463
Contact: Brent Rolling)
E-mail: mohamed*ssaacoustics.com E-mail: bcritreswest.com
MECHANICAL ENGINEER:
The Cweenbusch Group
1900 West Nickerson St., Suite 201
Seattle, WA 98119
Ph: 206. 318. 0565
Fax: 206. 318. 0641
Contact: Dylan -Ram
E-111811: DylanTegreenbuschcom
REGULATED MATERIALS
PBS Engineering and Environmental
2511 Eastlake Ave. E, Suite 100
Seattle, WA 58102
Ph: 206. 232. 5635
Fax: 206.162. 4180
Contact: Tim Ogden
E-mail: tim ogclen•pbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Gmtrp
123 North Washington St 1200
Boston, MA 02114
Contact: Tim Fenlason,
Cynthia Maeda
E-mail: tfenlasonsjonespaynacom
CMasdamionespaynacom
STRUCTURAL ENGINEER:
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, LUA 98121
Ph 206. 622. 4580
Fax: 206. 622, 0422
Contact: Ron Martinson
E-mail: ronrnmpom-ereineers.com
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
PERMIT CENTER
VICINITY MAP (NTS)
($,
b1-6 0 117
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability C;nrapany
4000 DELREDGE WAY SW
STATE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
OCTOBER 19, 2012
0810.03.2330
ce
0
ce
0
w
z
z
0
0
MPROVEMENTS
›-
0www
0
z0
a
Lu
ce
AIP NUMBER
3-53-0058-045
TUKWILA WASHINGTON
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
Jo
PROJECTIVANAGER
ML&TF
DRAWN
LB&CP
PROJECT
INFORMATION,
DRAWING
INDEX,
DIRECTORY
TO.0
0810.03.2330
18" x 241' EXIST.
ATTIC ACCESS —
PANEL
IwINCs
ROOM
15411-1
KITC44EN
• EIDIROOM
2
SPECIAL NOTES:
1. SECURITY ALARM SYSTEM PRESENT. COORDINATE WITH HOMEOWNER
FOR TEMPORARY DISCONNECTION AND RECONNECTION OF THE
SECURITY SYSTEM PRIOR TO START OF WORK
2. REFERENCE 5/A2.2 FOR SMOKE CARBON MONOXIDE DETECTOR
INSTALLATION DETAIL.
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' IIITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE NE WOO< OF
THESE DOCUMENTS AND RETURN THEM TO THEIORIGINAL LOCATIONS AT TE COMPLETION CF WORK DAILY.Y.
HOMEODUNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE ANP TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO $:00 AM EACH
DAY. IdoMEOUNEI S WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, AND'REINSTALL E)(ISTING WINDOW CO\ERING5 IN ALL ROOMS.
5. DOORS OR WINDOWS SCHEDULED TO ISE REPLACED SHALL NOT EE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE REMOVAL
AND REPLACEMENT OF A DOORAND/OR WINDOW MIDST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 FM.
6. DO NOT NSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OFENNGS ARE DETERIORATING, (EG: WOOD ROT,
TERITE DAMAGE) CONTACT 1ECI-INICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
'R. ADD SOLID WOAD BLOCKING AT WINDOWS.
a FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WNDOW FLASHING DETAILS SHEET FOR WINDOWREPLACEMENT..
EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON NE SANTE DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
10. INSTALL SAFETY GLAZINCs PER CODE. SEE IUINDOW TYPE SCHEDULE.
11. ALL WORK AREAS SHALL BE Bi DOM -CLEANED AT THE END OF EACH WOR[ DAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SIELVINOi A5 REQ'D AND RE -CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 5O AS NOT TO NTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES:
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY' ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WEA, PATCH DISTURBED AREA TO MATCI-1 (E) TEXTURE AND COLOR. THERE ARE
SEVERAL CsRADES OF TEXTURE AND DENSITY OF CEILINC6 PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PULS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED
IT. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11 INSTALL SMOKE DETECTORS. SEE ARCHITECTLIRAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET MO FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS MEET.
IS. CONTRACTOR 15 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 3611 CLEAR IN FRONT OF CONTROL PALL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY NSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20. MAXIMUM PC ER OUTACaE 16 WWI NaIR5. POILER 1116T EE PROVIDED At 'EVIDENCE BEFORE &DV AM 4 AFTER AFTER MO PJM
MAIN FLOOR PLAN
1/4". = 1' - 0"
A. WEST ELEVATION
161_411
111-1011
41-311
.x 2411 EXIST.
ATTIC ASS
- . PATEL' _ —
.
•
. • ✓ .
" -
\: /
/
\1-
32'4"
B. NORTH ELEVATION
PLAN KEYNOTES
0 DEMOLISH (E) WNDOW, CASNG AND TRIM. INSTALL ACOUSTICAL WINDOIU ASSEMBLY. REF. WINDOW SCHEDULE.
00 DEMOLISH EXISTING DOOR(6),FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR FWE, CASING, TRIM, THR E LD AND
�. STORM DOOR REF. DOOR9GH1= DULE.
3 REMOVE AND SURPLUS EXISTING A/C UNIT TO I40MEOIINER
4: DEMOLISH EXTERIOR WALL ASSEMBLY A5 REQUIRED- INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A22 FOR DETAIL. COORDINATE WIN
MECHANICAL DOCUMENTS.
5 INSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS.
6.2DETAIL.
EXISTING Cs VENT(S) IN ATTIC. REF. 3/4A2 FOR Di= L
INSTALL VENT BAFFLE(S) AT EX1 ABLE END
CI IIVStALL. VENT BAFPLI=(3) AI EXISTING Rotes vl~ N1(5) IN ATTIC. REF. 4/422 EOR DETAIL.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR BLOCK ACCESS TO HOMER DRIVEWAY.
C. EAST ELEVATION
LEGEND
/E1
.... ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR/ DOOR
OR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLAS6 STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
1)111 FRES-1 AIR INTAKE GRILLE.
REFER TO MECH.FOR UNIT
PHOTO DETAIL
EXTERIOR !ELEVATION PHOTO VIEW
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 14
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
?EMIT CENTER
D. SOUTH ELEVATION
D 13OLI7
111111111111
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE
R EATI•IER TEXTURED CEILING OVER AT A
MIN. OF 2411 FROM EDGE OF PATCH NG.
HATCH (E) TEXTURE AND PANT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND UUl-IDLE HOUSE VENT INSTALLATION.
REF. MECH. It ELECT.
REF. GENERAL NOTE 11
c INSULATION
ATTIC INSULATION DAM
Sp INSTALL BATTERY OPERATED SMOKE'
DETECTORS
SO: INSTALL BATTERY OPERATE SMOKE ;I
CARBON MONOXIDE DETECTORS
GAS METER
SOFFIT FOR MECHANICAL DUCTING
S.MSTEMPER
ARCHITECTS
A Protes®ional Limited Liability Company
4000 'DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 08100
(206) 624-2777 FAX (206) 824-2873
OCTOBER 19 2012
0810.03.2330
0
Z
w
z
z
0
V
C7
Z
MPROVEMENTS
>-
W
AIP NUMBER
3-53-0058-045
z
O
0
c
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
L B &`CLP
FLOOR.
PLANS
NOTES
Al
.0
0810.03.2330
WINDOW TYPES
1.
DOUBLE -I -MG
2.
HORIZONTAL
)0( SLIDER
3.
SLIDER) FIXED/ SLIDER
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
DETAIL
SET
A
LIVING ROOM
3
s' -B" x 3'-1"
STAIN/STAIN
SAFETY GLAZING REQUIRED
1/42.0
5
L IvING ROOM
I
I'-11" x 3'-11"
STAIN/STAIN
1142.0
C
LIVING ROOM
I
1-11" x 31-1111
STAIN/STAIN
1/4.2.0
D
BEDROOM 1
2
41-10" x 2' -Il"
STAIN/STAIN
1/A2,0
E
KITCHEN
2
31-10" x 2'-I1"
STAIN/STAN
SAFETY GLAZING REQUIRED
I/A2.0
F
KICI4EN
2
2' -II" x 21-11"
STAIN/STAN
1/42.0
6
BEDROOM 2
2
4' -1111 x 2'-10"
STAIN/STAIN
114213
CAREFULLY LFT (E) WALL UNDERLAYMENT
AND INSTALL SELF-ADI-ERNG MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OYER PENETRATION
FLASHING. t -r AT HEAD AND JAMBS.
REMOvE (E) T-111 SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAN
(E) COURSING. PANT MODIFIED SIDING
TO MATCH (E)
PRE -PRIMED, GALv SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR
TO 5E SELECTED IN THE FIELD
TRIM- MATCH (E) TOM. PRIME ALL
SIDES AND PAINT To MATCI4 (E) TRIM.
COLOR TO 5E FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW A,56EMELY
REMOVE (E) T -1I1 SIDING FOR
NSTALLATION OF NEW WINDO(U TRIMS
AND REATTACHMENT OF (E) SIDIlsiG TO
WINDOW OPENING FRAMING. LIFT (E)
WALL UNDERLATMENT AND WALL
WINDOW NAILING FLANGE OYER SELF
ADHERNG MEMBRANE PENETRATION
FLASI-ING. INSTALL SECCND LAYER OF
SELF ADHERING MEMBRANE OVER
NAILNG FLANGE AND LAP UNDER (E)
WALL UNDERLAYMENT. CAULK NEW
vERTICAL SIDING JOINTS 4 SET NAIL
I-IE45 FLUSH. PANT MODIFIED sioNa
TO MATCH (E) SIDING
(E) t -1I1 SIDING
(E) WALL UNDERLAYMENT
(E) ExTERIOR SI-EATI-ING
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E)
TRIM. COLOR TO BE FIELD
DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOUJ ASSEMBLY
1.6
1 1
1J
11
kni
(E) cLLPJ
(E) WALL UNPER_AYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING MEMBRANE
TOLICI-1 UP PAINT,
AS REQD
WINDOW HEAD
CcNTINUOUS
SEALANT, -rrp.
soup LLOOD TRIM
WO_ JAMB LINING. IN151-1 TO
MATCH (E)
SEALANT 4 IBACKER ROD
SHIM AS NECESSARY
FILL GAP LLI/ BATT
INSULATION
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAIL FLANGE
1711]
4 II I
WINDOW JAMB
(E) GLUB
TOUCH U10 PAINT,
AS Real:,
CONTINUOUS
SEALANT, rtp.
SOLID WOOD TRIM
SHIM' AS tecEssARY
FILL GAP W/ BATT
INSULATION
/4"
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E)
COLOR TO 5E FIELD DETERMINED
REMOVE (E) T-111 SIDING FOR
INSTALLATION CF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR
RE NSTALL SIDING AS REQ1D. PAINT
MODIFIED SIDING TO MATCH (E)
SIDING
(E) ExTERIOR SI-EATI-ING
5ACKER ROD 4
SEALANT
3/411 WOOD SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
TOUCH UP PAINT,
45 REQ1D
SELF -ADHERING
MEMRANE
f E)
WINDOW SILL
T-111 SIDING - WINDOW DETAIL SET
3" = 1' - 0"
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING VVINDOVVOPENING DIMENSIONS.
3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'AON WINDOW TYPES, SCHEDULE & DETAILS SHEET.
1" mkt.
I/iti!
HEMMED EDGE I I END CI -°"E
SLOFE
J
HEAD FLASHING DETAIL TYP.
3" = 1' — 01
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 1 4
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
oERMIT CENTER
Qin
S.MSTEMPER
ARCIIITECTS
A Nocessional Limited Lability Company
4040 DELRIDGE WA' SW
SUITE 200 • SEATTLE, WA 9E1106
(206) 624-2777 • Jl (206) 624-2073
OCTOBER 19, 2012
0810.03.2330
ce
0
z0
uJ
ce
z
z
0
00
MPROVEMENTS
w
2
w
ce
w
0
LL
0
w
0
w
AIP NUMBER
3-53-0058-045
1—
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
J
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.2330
DOOR TYPES
A
FLUSH SCW
2 LITES, 4 PANELS
W/ FFaTED SAFETY
GLAZING
W/ :OBSERVATION PORT
EXTERIOR
SINGLE LEAF STORM
uu, SAFETY GRILLE
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ ECT.
HARDWARE
SET `/ FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
1
LIVING ROOM
A
3'-0" x 6'-8"
STAIN/ STAIN
WW -1 / S@g
DK -4
LOCK -1
1/42.1
2
KITCHEN
A
2'-S" x 1-13"
STAIN/ STAIN
HW -I / 603
DK -3
LOCK -1
1/42.1
3
LIVING ROOM
a
3'-0" 6'-1"
1/A2:1
4
KITCHEN
8
2'45" x 8'-8"
1/12_1
REMOVE (E) T-1I131DI 1 FOR
INSTALLATION OF NEW DOOR ASSEMBLY
AND TRIM: REPLACE OR RE INSTALL
SIDING AS REQ'D. MAINTAIN (E)
COURSING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADI -TERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OYER PENETRATION
FLASHING. T1'= AT HEAD AND JAMBS.
PRE -PRIMED, GAL( SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADI -TERING Mme. COLOR
TO BE SELECTED IN THE FIELD
CONTINUOUS SEALANT BEHIND Z SAR
FRAME
STORM DOOR PER SCHEDULE
2" MIN.
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
TOUCH UP PAINT,
AS REQ'D
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
SHIM ASNECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
REMOVE (E) T-111 SIDING FOR INSTALLATION
OF. NEW DOOR TRIMS AND REATTACHMENT
OF (£) SIDING TO DOOR OPEN1146 9 Ar1ING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK
NEW VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PAINT MODIFIED SIDING TO
MATCH (E) SIDING
(E) T-111 SIDIN.4
CONTINUOUS 3EALLANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
DOOR HEAD
(E) EXTERIOR SHEATHING
EXISTING FRAMING
KERF AS REQUIRED. FOR MATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER-STRIPPN+IG
JAMB BEYOND
2" MIN
WOOD DOOR PER SCHEDULE
DOOR SHOE
211 MIN.
DOOR JAMB
DOOR SIJJEEP
ALUMINUM TIINESNOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
SILL IN 14EAD OF SEALANT
-`
#1„
11 lag a I
DOOR SILL
TOUCH UP PAINT,
AS REQ'D
CONTINUOUS
SEALANT, TVP.
$OLID tUOQD TRIM`
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER HEDULE
T-111 SIDING - DOOR DETAIL SET
= 1'-0"
TYPICAL DOOR SCHEDULE NOTES
1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN
SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS
AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK.
5 FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET.
SLOPE
1H Afirl.
1/ :'' min.
1�r
HEMMED EDGE I
END CLOSURE
A
.M
HEAD FLASHING DETAIL TYP.
3" 1' _.011
REVIEWED FOR
ODE COMPLIANCE
APPROVED
w'. FEB 1.4 -mil
•
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
PERMIT CENTER
� (3-0`7
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 'DELRIDGE WAS' SW
SUITE 200 • SEATTLE, WA 98106
(208) 624-2777 • FAX (2O B) 24-2973
OCTOBER 19, 2012
0810.03.2330
ce
0
-J
Z
0
cez
LLL
z
KING COUNTY
MPROVEMENTS
AIP NUMBER
3-53-0058.045
Z
O
H
CO
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&C_P
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.2330
CARERILLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF-4rA*1;2Na MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TY!' AT I -EAP MP JAMBS.
EMC)VE (E) T -1I1 SIDING FOR
INSTALLATION OP VENT FIXTURE AND
FLAS14ING. REPLACE OR RE INSTALL
BIDING AS ar). MAINTAIN (E)
COURSING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
Fike-FiRrsp, GALV SHEET METAL
FLASHING UJ/ F. END CAM UNDER
SURPACE MOUNTED REGLET ANP CAP
FLASHING_ PANT COLOR TO SE
SELECTED FN. TI4E FIELD
PAINT VENTILATION HOOD,
COLOR TO BE SELECTED IN
ne FIELD
EXTERIOR VENTILATION HOOD.
REF, MECH.- PAINT INTERIOR 11.1/
ACOUSTICAL DAMFNG
COMPOUND. SFT N MASTIC AT
EXTERIOR TRIM.
REPLACEMENT SIDING AS REQUIRED -
(E) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
2x BLOCKING
2X2 CONTINUOUS 51.0•KNG,
4 SIDES
2x H,LOCKNG
EXIST. WALL
CONSTR.
EXIST. GABLE
VENT
NEUJ GALV.
HARAVARE
CLOW
(2) SIMPSON A-34
• EACH SIDE PANEL
OPEN Top
i" cox PLYIL1001:)
AT (3) SIDES
1" ouENS CONING 4103
INSULATION, TYPICAL.
SECURE WITH PIN TYPE
FASTENERS TO PL'YWOOt)
1BACK AND sloe PANEL
NOTE:
1. AFTER FABRICATION, BAFFLE SHALL BE SECURELY
ATTACHED N POSITION.
2. NEW BAFFLE SHALL SE Al LEAST AS WIDE AS
THE EXISTING vENT OPENING.
EXISTING ROOF
(E) ROOF FRAMING
(E) EA VE VENT. MAY VERY
AT EACH PROPERTY_
_,---------------
-----'
___---- „-----
------
•
SLOW IN CELLULOSE
INSULATION WITH A COMBNED
vALUE OP NOT LESS THAN
R-38
INSULATION DAM
(E) WALL FRAMNG
EXISTING VENT COVER
J2ciri-HxYlY
CR055 SECTION
EXISTING ROOF
STRUCTURE
NEW 2"X SPACER AS
REQUIRED TO PROVIDE
CLEAR AIR SPACE
LATERAL SECTION
6" MIN. TYPICAL. Top
BOTTOM
NEW 1" INSULATION BOARD
GLUED TO NEW BA"
EXTERIOR GRADE
PLYWOOD.
CEILING
4" MIN
BEST HERE
ACCEPTABLE
HERE
NOTE REMOVE EXISTING SMOKE
DETECTORS, CUT AND PATCH CEILING AS
REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND
TEXTURE AND PANT TO FILL ALL HOLES
LEFT MOM EXISTING aNDITICN. PAINT
TO MATCH SURROUNDING CONDITIONS.
\ 4
SIDE WALL
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 14
•
City of Tukwila
BUILDING DIVISION
b (2-0/-(7
RECEIVED
CITY OF TUKWILA
FEB 072013
PERMIT CENTER
DETECTOR INSTALLATION DETAIL TYP.
3" = 1' - 01'
swim
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 08106
(206) 624-2777 • FAX (206) 624-2973
OCTOBER 19,2012
0810.03.2330
ce
0
z
0
ce
KING COUNTY
MPROVEMENTS
AIP NUMBER
3-53-0058-045
1-
0
DATE
OCTOBER 19,2012
ISSUED
100% CD
PROJECT ARCHITECT
J
PROJECT MANAGER
M L & T F
DRAWN
LB&CP
DETAILS
A2.2
0810.03.2330
LIFT (E) WALL
LNNIDERLAYMENt
AWAY LOOSELY
FROM (E) 51-EATHING
AT JAMBS AND HEAD
BUTTEWLY
COQ, TIP.
NOTE: REMOVE (a) 5IDNG BACK FROM (1=) RA. AS REQ'D
(E) SIDING NOT swam N FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
12"
LAP SILL MEMBRANE
FLASHNG 2-1,r1"
OVER (E) IDLDG.
PAPER AT SILL.:
EXTEND 1 in BEYOND
W. AT EA. END OF
SILL.
(E) U ALL
UNDERLAYMENT
AT SILL
I1n" TYP.
MEMBRANE FLASHING AT SILL
(E) SHEATHING
CUT SILL
FLASHING TO
EDGE OF R.O. AS
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
i? MIN
5 Jr
puTTERFLY CORER FLASHING
SCALE: NTS
LIFT (E) BLDG:
PAPER AWAY
LOOSELY PROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) &IDINC NOT
SHOWN FOR CLARITY.
NOm REMOVE (E) SIDING BACK FROM (E) R0. AS RQ1
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE PLASHING
14A5 BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLAS4NG AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
S14011L.1 FILL FLANGE
NAIL HOLES. REMOVE``
EXCESS MATERIAL
DO NOT SEAL FLAN
AT WINDOWSILL
(E) WALL
INDERLAYMENT
AT SILL.
REMOVED
ELEVATION VIEW
1401E: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECI.ft4ICAL REPRESENTATIVE OF DISCREPANCIES
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
ANCHORAGEBEND
NAILS DOWN
OVER NAL
FLANGE, HEAD
ONLY.
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
EDGE OF (E)
SIDING, SHOWN
DIAGRAI'ATICALLY.
(E) SIDING:
NOT SHOW
FOR CLARITY.
LAY (E) WALL
UNDERLAYMENT
SACK DOWN
OVER FLAIME
FLASHING AT
JAMBS
NOTE: REMOVE (E) SIDNGS BACK FROM (E) IRO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMIBIRME FLASHING
14AS SEEN INSTALLED.
-r
COHEAD FLASHING PREPARATION
SCALE: NTS
WHERE REQUIRED, TRIM
(E) WALL
UNDERLAYMENT AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRIM
(FOLLOWING STEPS).
(E) WALL
UNDERLAYMENT
NOTE: REMOVE (E) SIDING BACK FROM (E) W. AS RECI'D
(E) SIDING NOT SHOW FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
14A5 BEEN INSTALLED.
1;1/2" TYP
CUT JAMS FLASHING Ta
EDGE OF WINDOW OPENNG
AS SHOWN. EXTEND 1-1/2"
BEYOND EDGE OF
OPENING A7 HEAD, JAMBS,
AND SILL
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
TILL SCATHING
E;)
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SNOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEM RAKE FLASHING
1-1A5 IBEEN INSTALLED.
INSTALL JA115 FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
INSTALL 5HT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER
NOTE: REMOVE (E) SIDING BACK FRG.fl (E) RA. AS REQ'1?
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED ALLOW 1/5" CLEARANCE
IBETWEEN`FLASHING AND
IBOT. EDGE OF (E)
SIDING.,
TRIMMED EDGE
OF (E) SIDING,
SHOUN
DIAGRAMATICALLY.
(E) SIDING NOT
5HOILN FOR
CLARITY.
HEAD FLASHING INSTALLATION
8 SCALE: NTS
(E) WALL
UNDERLAYMENT
CUT HEAD.
FLASHING To
EDGE 01= WINDOW
OPENING AS
SHOWN EXTEND
1-1/2" BEYOND
W. AT HEAD
AND JAMBS.
ADHERE.
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SNOW l FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLAS141NG
1-1A5 BEEN INSTALLED.
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
WINDOW FLASHING INSTALLATION
SCALE: NTS
q
i
/
Nx
t\
ELEVATION VIEW
1401E: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECI.ft4ICAL REPRESENTATIVE OF DISCREPANCIES
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
ANCHORAGEBEND
NAILS DOWN
OVER NAL
FLANGE, HEAD
ONLY.
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
EDGE OF (E)
SIDING, SHOWN
DIAGRAI'ATICALLY.
(E) SIDING:
NOT SHOW
FOR CLARITY.
LAY (E) WALL
UNDERLAYMENT
SACK DOWN
OVER FLAIME
FLASHING AT
JAMBS
NOTE: REMOVE (E) SIDNGS BACK FROM (E) IRO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMIBIRME FLASHING
14AS SEEN INSTALLED.
-r
COHEAD FLASHING PREPARATION
SCALE: NTS
WHERE REQUIRED, TRIM
(E) WALL
UNDERLAYMENT AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRIM
(FOLLOWING STEPS).
(E) WALL
UNDERLAYMENT
NOTE: REMOVE (E) SIDING BACK FROM (E) W. AS RECI'D
(E) SIDING NOT SHOW FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
14A5 BEEN INSTALLED.
1;1/2" TYP
CUT JAMS FLASHING Ta
EDGE OF WINDOW OPENNG
AS SHOWN. EXTEND 1-1/2"
BEYOND EDGE OF
OPENING A7 HEAD, JAMBS,
AND SILL
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
TILL SCATHING
E;)
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SNOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEM RAKE FLASHING
1-1A5 IBEEN INSTALLED.
INSTALL JA115 FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
INSTALL 5HT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER
NOTE: REMOVE (E) SIDING BACK FRG.fl (E) RA. AS REQ'1?
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED ALLOW 1/5" CLEARANCE
IBETWEEN`FLASHING AND
IBOT. EDGE OF (E)
SIDING.,
TRIMMED EDGE
OF (E) SIDING,
SHOUN
DIAGRAMATICALLY.
(E) SIDING NOT
5HOILN FOR
CLARITY.
HEAD FLASHING INSTALLATION
8 SCALE: NTS
(E) WALL
UNDERLAYMENT
CUT HEAD.
FLASHING To
EDGE 01= WINDOW
OPENING AS
SHOWN EXTEND
1-1/2" BEYOND
W. AT HEAD
AND JAMBS.
ADHERE.
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SNOW l FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLAS141NG
1-1A5 BEEN INSTALLED.
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
WINDOW FLASHING INSTALLATION
SCALE: NTS
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL WD. TRIM. SIiTT
TIGHT TO TRII'"IED EDGE
of (E) SIDING. APPLY
SEALANT BEAD t0
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE I/4°-3/5" GAP
BETILEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES;
1: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS
"SELF ADH;ARINGs MI=MSRANE FLASHING" TYPICALLY
i;EFERED t0 AS "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5 AND 6" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW 1446 SEEN SET IN PLACE,
SHIMMED, AND ANCHORD.
4: DETAILS "1 AND 5" RI=FER' TO SHEET METAL HEAD
FLASHING.
5- DETAILS REFERS TO WOOD TRIM AND CAULK
JOINTS
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 14 "nil
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
PERMIT CENTER
�J 13-0 47
S.M STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WADY' SW
SUITE 260 • SEATTLE, WA J8106
(2D8) 824-2777. FAY (296).424-2973
OCTOBER 19, 2012
0810 03.2330
0
0
Itt
J
z
0
cez
z
z
0
0
MPRO'VEMENT
w
w
ct
cnw
0
z
0
ce
ce
AIP NUMBER
3-53-0058-045
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
Jo
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
FLASHING
DETAILS
■
A2.3
0810.03.2330
/
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL WD. TRIM. SIiTT
TIGHT TO TRII'"IED EDGE
of (E) SIDING. APPLY
SEALANT BEAD t0
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE I/4°-3/5" GAP
BETILEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES;
1: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS
"SELF ADH;ARINGs MI=MSRANE FLASHING" TYPICALLY
i;EFERED t0 AS "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5 AND 6" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW 1446 SEEN SET IN PLACE,
SHIMMED, AND ANCHORD.
4: DETAILS "1 AND 5" RI=FER' TO SHEET METAL HEAD
FLASHING.
5- DETAILS REFERS TO WOOD TRIM AND CAULK
JOINTS
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 14 "nil
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
PERMIT CENTER
�J 13-0 47
S.M STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WADY' SW
SUITE 260 • SEATTLE, WA J8106
(2D8) 824-2777. FAY (296).424-2973
OCTOBER 19, 2012
0810 03.2330
0
0
Itt
J
z
0
cez
z
z
0
0
MPRO'VEMENT
w
w
ct
cnw
0
z
0
ce
ce
AIP NUMBER
3-53-0058-045
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
Jo
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
FLASHING
DETAILS
■
A2.3
0810.03.2330
EXPIRES: 9/08/2014
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
4C
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
SRC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
IN/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEIUNG
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
SEATTLE RESIDENTIAL CODE
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
•
ABBR
•
OR X
0
X/Y //
pESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
W/X/7/4;
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC„ AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORKND OPERABLE' MECHANICAL
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE A.
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED
BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
2. THE DESIGN OF MECHANICAL REPRESENTATIVE COORDINATE
APPROVAL OF THE TECHNICAL
MAY BE SUBSTITUTED. PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA,.AND HAS THE WRITTEN
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4'-O" AFF. UNLESS NOTED OTHERWISE.
9.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 1O'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3'-O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
SYMBOL
$
G -X
XX
ABBR
+ f +
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VD VOLUME DAMPER
RA/EA RETURN AIR OR EXHAUST AIR DUCT
RG RETURN AIR GRILLE
SA SUPPLY AIR OUTLET, SIDEWALL
SA SUPPLY AIR DUCT
RA/EA RETURN AIR OR EXHAUST AIR DUCT
SD SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
CD OR THERMOSTAT
EQUIP ID# EQUIPMENT LOCATION
M
NG
•
0
ra
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPUANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL/ELECTRICAL COORDINATION
MARK
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
EXTERIOR
90
DESCRIPTION
VOLTS
PH
1,2
1,3
REMARKS:
1. 'PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEIUNG SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
23
26
23
26
N/A
23
26
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS:
1 - VERIFY
2 - DISCONNECT
QUANTITY FROM PLANS (TYPICAL ALL)
SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
REMARKS
WC -1
EXTERIOR
90
337
G.08"WG
7"016
1,2
1,3
REMARKS:
1. 'PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
(SQ. FT.)
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.2330
865
2
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51-51-1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION
MIN VALUE INOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R-8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEIUNG
R-8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R-8
1,3
IN CEMENT SLAB OR IN GROUND
R-5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEIUNG SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
THERMOSTAT/SWITCH HOURS OF OPERATION
SET FURNACE THERMOSTAT TO OPERATE 1 OF EVERY 2 HOURS.
RECEIVED
CITY OF TUKWILf
FEB 0 7 2013
PERMIT CENTER
MECHANICAL VENTILATION CALCULATION
PER SRC M1508.3
QF = QR / (&EGR X F)
QR = (FROM TABLE 1508.2) 4.
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION La.
QF = 45 / (1 X 1/2) = 90 CFM
b tic
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
S.M. STEMPER
ARCHITECTS
A Professional limited liability Company
4000 DELRIDGE WAY SW
SUM 200 • SEATTLE, WA OHM
(8116) RR4-2777 FAX (8O9) 684-8973
THE GREENBUSCH GROUP, INC
040000•0411010
1000 I1EST 2111EET AMIE 901 SOME. 1111% OC11D
(200) 370-0509 Gni 378-0041 FAX
Cri
00
MPROVEMENTS
0
u�
0
AIP NUMBER
3-53.0058-45
TUKWILA WASHINGTON
DATE
09/1012012
ISSUED 100% CD
PROJECT ENGINEER.
DO
PROJECT MANAGER
DO
DRAVVN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M 1.0
081003.2330
GAS
METER
BEDROOM
1
KITCHEN
18» x 24 EXIST. -
ATTIC ACCESS
PANEL
LIVING
ROOM
BEDROOM
2 ESGZ
OUTSIDE AIR DUCT,
SIZE AND ROUTE
PER PLAN
CEILING
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
z
0
11.1
X
MOD, INTERLOCK
TO FURNACE
POC
FURNA
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
FLOOR
FURNACE ELEVATION
SCALE: NONE
NORTH
18°° x 24" EXIST;
AT11C ACCESS
PANEL
(E)SIDING
ATTIC MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
SHEET METAL
FLASHING
2X2 BLOCKING
WALL CAP
2X2 BLOCKING
f
�I
HARD DUCT
PER PLAN
2X BLOCKING
2X BLOCKING
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS.
WALL CAP DETAIL
SCALE: NONE
IFFN
(E.1
SEE
DRAWING NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED
FURNACE SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT
MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY
HAZARDOUS OR NOXIOUS SOURCE PER SRC
M1508.6.6.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING
MODIFICATION. AT THE TIME OF FINAL INSPECTION,
THE WHOLE HOUSE FAN SHALL OPERATE FOR AT
LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR
HEATING, TO SATISFY THE SEATTLE RESIDENTIAL
CODE, CHAPTER M1508.5.2 (CONTROLS FOR WHOLE
HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF
OPERATING THE VENTILATION SYSTEM WITHOUT
ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES).
COORDINATE FINAL 11ME 'SETTING WITH PROJECT
REPRESENTATIVE.
4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT
WORK HAS BEEN COMPLETED AND PRIOR TO
COMMENCEMENT OF TAB WORK, PERFORM THE
FOLLOWING:
A) REPLACE AIR FILTERS IN THE FURNACE
AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW
FILTERS.
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO
INSTALL WALL CAP. REFER TO ARCHITECTURAL
DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE
SEC 1412,4 COMPUANT THERMOSTAT AS SPECIFIED.
AFFIX A LABEL TO THE CONTROLLER THAT READS
"WHOLE HOUSE VENTILATION (SEE OPERATING
INSTRUCTIONS)" PER SRC M1508.5.2.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE
MINIMUM DUCT INSULATION THICKNESS SCHEDULE
ON 'M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E)
FURNACE IS WITHIN 4 FEET OF FURNACE RETURN
INLET PER SRC M1508.5.1.
CUT DUCT AND INSTALL A VOLUME DAMPER ON
THE EXISTING FURNACE RETURN AIR DUCT. VOLUME
DAMPER SHALL ALLOW FOR BALANCING THE
OUTSIDE/RETURN AIR TO PROVIDE THE SCHEDULED
VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR
DUCT SIZE PRIOR TO ORDERING. IF A VOLUME
DAMPER EXISTS IN THIS LOCATION, IT MAY BE
REUSED.
S.M. STEMPER
ARCHITE CTS
A Profoosionol Monad U brnty Company
4000 DELRIDGE WAY SW
SLIT E 200 SEATTLE, WA 98108
(200 684-2777 PAX (808) 824-2072
1'HE GREENBU4Cii GROUP, INC
(208) 378-0589 gm. SIE(208) 375-0641 FAX
201 SSOTIE. Ilk 08110
0810.032330
la
Ct
ctUj
Ct CI)
Lu
0
0
ELY IMPROVEMENTS
ASHINGTGN
RESIDENTIAL
AFP NUMBER
3-53-0058-45
DATE
09/10/2012
ISSUED 100% CD
D13 0M7
SEPARATE
PERMIT AND
APPROVAL
REQU RED
RECEIVED
CITY OF TUKWII_w
FEB 0 7 2013
PERMIT CENTER
EXPIRES: 9/08/2014
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.2330
ELECTRICAL LEGENE,
SYMBOL
DE' --4 - 1014
844141301.,
DESCRPTION
LIGH1ING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIIEMENTS.
41444,_
-I'
BRANCH CIRCUIT WIRING AND OONDUIT AS WOUND FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. OARING AND CONDUIT STE MAY NOT
APPEAR ON PLANS), PROVIDE CONDUCTDRS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2°C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
i INDICATES ISOLATED GROUND.
DAMPER CONFECTION
D
NON-FUSED DIS031.IECT VETCH
0
MAST, WEATHERHEAD
D
TOGGLE TYPE MOTOR DISCONNECT SWITCH 'MTH 'THERMAL OVERLOADS
--.--
BRANCH CIRCUIT HOME RUN,i...P
SMOKE DETECTOR
1:23
ELECTRICAL METER
i
TIMER OPERATED SWITCH
-
AERIAL MINCE CONDUCTORS, COMMUTE WITH UTILITY.
0
THERMOSTAT
CEILING MOUNTED FIRE ALARM -VEUAL STROBE LIGHT
UNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR
ELECTRICAL - PROJECT NOTES
1 CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3 MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LJNES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
0 PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH.
TO AMA=
MUER NMI' • '
Eg-E.7.3
to Fueucg-
PAMPER,/
EE L2OC'
t\? OM1
NORTH
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
PERMIT CENTER
SEPARATE
PERMIT AND
kPPROVAL
RETIRED
11111
SeMSTEMPER
ARCHITECTS
A Professional Lunited Liability Company
4-000 DELRIDGE WAY SW
SUITE 290 SEATTLE, WA 9B100
(2OB) 1324-2777 • FAX (2013) 624-2973
1111.11NIERS. 11119
OW
IH WM 611111/11. Ian WI
11141414 INAMMOM
IMININISM 41111 1111119
PM MID SWAM
0810.03.2330
zcI
LU
AIP NUMBER
MPROVEMENTS
›-
0
Lu
uJ
Lu
U)
0
z
-J
LU
0
C7)
LU
0
1-
0
-J
5-53-0058-045
DATE
SEPT 17,2012
ISSUED
95%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
BCR
FLOOR
PLANS
NOTES
E1.0
0810 03.2330