Loading...
HomeMy WebLinkAboutPermit D13-048 - SPADONI RESIDENCE - REMODELSPADONI RESIDENCE 5710 S 133 ST D13-048 City ofii'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 2172000330 Address: 5710 S 133 ST TUKW Suite No: Project Name: SPADONI RESIDENCE DEVELOPMENT PERMIT Permit Number: D13-048 Issue Date: 03/19/2013 Permit Expires On: 09/15/2013 Owner: Name: SPADONI MARK A Address: 5710 S 133RD ST , TUKVVILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RDS , SEATTLE WA 98108 Contractor: Name: S K M CONSTRUCTION INC Address: 14415 SE 143 PL , RENTON, WA 98059 Contractor License No: SKMCOI*052L3 Lender: Name: Address: Phone: 206-296-7437 Phone: 425 235-5569 Expiration Date: 12/30/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $18,756.00 Fees Collected: $748.15 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT **continued on next page** doc: IBC -7/10 D13-048 Printed: 03-19-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non -Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: P- `(3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: 1-io`fth Date: 31E111 -2) Print Name: C. a'1�'-� K i\f\rx-( C)(.\ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D13-048 Printed: 03-19-2013 this requirement. 11111 411 7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D13-048 Printed: 03-19-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No. b 'U Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 2172000330 Site Address: 5710 S 133rd St Tenant Name: Mark Spadoni Suite Number: Property Owners Name: Mark Spadoni Mailing Address: 5710 S 133rd St Floor: New Tenant: 0 Yes ® ..No Tukwila WA 98178 City State Zip CONTACT PERSON who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Day Telephone: (206) 296-7437 Mailing Address: 7277 Perimeter Road South Seattle WA 98108 E -Mail Address: Sharyn.Parker@kingcounty.gov City State Fax Number: (206) 269-7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Contact Person: Jesse Holgate Seattle WA 98106 or Timothy Fenlason E -Mail Address: jesse@smstemper.com/tfenlason@jonespayne.cce City State Day Telephone: (206) 624-2777 Fax Number: (206) 624-2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: E -Mail Address: H:\Applications\Fonns-Applications On Line\2009 Applications\I-2009 - Permit Application.doc Revised: 1-2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 18,756 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fotms-Applications On Ling \2009 Applications\I-2009 - Permit Apphcation.doc Revised: 1-2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 979 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck • PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fotms-Applications On Ling \2009 Applications\I-2009 - Permit Apphcation.doc Revised: 1-2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In allcases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is, issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN' ._,,�. - • • �i� Signature: Date: 2/Z(/) Print Name J. Fenlason, SM Stemper Architects, PLLCDay Telephone: (206) 624-2777 Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:\ApplicationsTottms-Applications On Line\2009 Applications\I-2009 - Permit Application.doc Revised: 1-2009 bh Page 6 of6 City o'ukwilar Department of Commun ity Development 6300 Southcerter Boulevard, Suite 4100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: htw:/tvww. ci. tulnvila. wa. us SET RECEIPT Copy Reprinted on 02-19-2013 at 09:09:21 02/19/2013 RECEIPT NO: R13-00837 Initials: WER Payment Date: 02/19/2013 User ID: 1655 Total Payment: 5,833.28 Payee: PAMELA K KUEHL (BY PHONE) SET ID: 020713 SET NAME: KING COUNTY SOUND ABATEMENT SET TRANSACTIONS: Set Member Amount D13-045 811.18 D13-046 842.70 D13-047 716.64 D13-048 748.15 D13-049 622.10 D13-050 1,067.51 M13-038 167.70 M13-039 167.70 M13-040 167.70 M13-041 167.70 M13-042 167.70 M13-043 186.50 TOTAL: -' TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 5,833.28 TOTAL: 5,833.28 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES 000.322.100 2,897.75 MECHANICAL - RES 000.322.102.00.0 1,025.00 PLAN CHECK - RES 000.345.830 1,883.53 STATE BUILDING SURCHARGE 640.237.114 —2i0 TOTAL: 5,833.28 INSPECTION RECORD Retain a copy with permit Dt3—O4' INSP CTION`N0. PERMIT NO. C-'" V ` CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:Type 5 (��_ o o A! 2e3 of Inspection: o (Loa Ifr- ` n.s .S e vi -L Address: c Q DaoCall`d i 0/�b. / c,J, , (O (3Z J S Special Instructions: Date Wanted:. f -'" a.mi S'1 '(Z p.m. Requester: PhongtS — 63.1 ` 22, Z-/ Approved per applicable codes. Corrections required prior to approval. COMMENTS: • • D p I { i t'o lkorcA (Th Inspettor`._ A li Date: 5 (3 REINSPECTION FEE REQUIR +: Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Gale Contractor Services A Masco Contractor Services Company 16910 59th Ave. NE, Suite 100 Arlington, WA 98223 Installed Insulation Certificate "We certify that insulation material listed here and installed at the following residence surrounding conditioned space meet applicable federal, state, and local specifications." CITRECEIVED KWI APR 302013 PERMIT CENTER Loose Fill Kraft Unfaced Foil Foam Cellulose R -Value Thickness No. Pkgs Coverage Area Ceilings n 0 [� 0 R-38 12 3/4" 16 GEW 0 = D C7 0 0 Walls p p O = O O Basement =ED ED= = Q Crawlspace 0 ED[] 0 E] 0 Contractor Laura Halgren (Signature) Address or Lot Number 5710 S 133RD ST City, ST, Zip: Tukwila WA 98128 Title Office Manager Date Installed: April 29, 2013 pE PLAN R VI r NG SLIP ACTIVITY NUMBER: D13-048 PROJECT NAME: SPADONI RESIDENCE SITE ADDRESS: 5710 S 133 ST X Original Plan Submittal Response to Incomplete Letter # DATE: 02-07-13 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: �t3tr 421dingt&on 4111 Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02-12-13 Complete Incomplete ❑ Comments: Not Applicable Permit Center Use Only, INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please RouteIs,&] Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: C DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions DUE DATE: 03-12-13 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Prfer Friendly Page • General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name 5 K M CONSTRUCTION INC UBI No. 601577401 Phone 4252355569 Status Active Address 14415 Se 143Rd Pl License No. SKMCOI*052L3 Suite/Apt. License Type Construction Contractor City Renton Effective Date 6/23/1995 State WA Expiration Date 12/30/2013 Zip 98059 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SKMCO"093L6SKM CONSTRUCTION Construction Contractor General Unused 6/26/1991 6/17/1995 Archived SKMINI'976QL S K M INDUSTRIES INC Construction Contractor General Unused 11/13/2003 12/6/2009 Expired Business Owner Information Name Role Effective Date Expiration Date MORRISON, SHEILA K President 06/23/1995 Bond Amount MARKET SANDERS Agent 06/23/1995 06/25/2001 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 FIRST NATL INS CO OF AMERICA 6695979 06/17/2010 Until Cancelled $12,000.0004/26/2010 08/20/2012 4 DEVELOPERS SURETY Et INDEM CO 188889C 12/30/2001 Until Cancelled 08/01/2010 $12,000.0012/05/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 16 James River Ins 000495931 08/21/2012 08/21/2013 $1,000,000.00 08/20/2012 15 James River Ins Co 00049593 08/21/2011 08/21/2012 $1,000,000.0008/18/2011 14 COLONY INS CO EPK300402 08/21/2010 08/21/2011 $1,000,000.0008/20/2010 13 CENTURY SURETY CO CCP616634 08/21/2009 08/21/2010 $1,000,000.0001 /20/2010 12 AMERICAN STATES INS CO 01CH6810051 01/25/2009 01/25/2010 $1,000,000.0001/23/2009 11 AMERICAN STATES INS CO 01CH6810051 12/30/2008 01/25/2009 $1,000,000.00 12/23/2008 10 AMERICAN STATES INS CO 01CH6810051 12/30/2007 12/30/2008 $1,000,000.00 12/07/2007 9 AMERICAN STATES INS CO 01CD87273820 12/30/2006 12/30/2007 $1,000,000.00 12/19/2006 httnc•//fnrtrecc wa unv/lni/hhin/Print.asnx 03/19/2013 KING COUNTY INTERNATIONAL A 1 RPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00784C12 BID PACKAGE M-37 3-53-0058-045 SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOiSE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE NTUDES ALL INFORMATION. IN THE DRAWINGS AND MECHANICAL INCLUpINCx 131,17 NOT LIMITED TO SPECIFICATIONS APPLICABLE YES NO 1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL -FRAMED ACOUSTICAL WINDOWS. X 2. CUT DOWN QF WINDOWS TQ COMPLY WITH EGRESS REQUIREMENTS. X 3. WILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITI-I NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIMING GLASS DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X 8. INSTALLATION OF PET DOORS. X 9. INSTALLATION OF FIREPLACE FRESH AiR VENT. X l0. INSTALLATION OF CHIMNEY CAP. X 11 REGULATED MATERIALS ABATEMENT. X 12. ATTIC VENT BAFFLES. X 13. INSTALLATION OF ATTIC INSULATION. X 14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 18. INSTALLATION OF SMOKE DETECTORS. X 19. NEW ELECTRICAL PANEL / SERVICE. X 20. KNOB AND TUBE WIRING X FEL COPY Permit No. 4 8 PI-~ r-v!aw approval is subject to errors and omissions. c •'`" v truction documents does not authc:Yize t; ‘o_ ,; iy adopted code or ordinance. Receipt o; F` d Copy and conditions is acnowledged: By Date: City Of Tukwila BUI _DING DIVISION Re, iSIONS No cS7ore's PIS !i hr? m7 e to the scope cf t ^r'c I lithou+ prior Dnp prov21 of TL;;., -;:!a Building Divi^ c°i. will require nsw Wan submittal Ge'd:tional pian Ce'I! • '1 fa, FOR: r`,"Lchanicai cctrical ��I tubing '!I as Piping of Tukwila DiVIczION SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Seattle, WA APPLICABLE CODES: 2009 International Residential Code, Interna tlona l Fire Code, International Mechanical Code 2112000330 ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) V B NON SPRINKLERE3 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 14 ,r,,, City of Tukwila BUILDING DIVISION LEGAL DESCRIPTION: TRACT 65 OF EAST RIVERTON GARDEN TRACTS NO. 2, AS PER PLAT RECORDED IN VOLUME 12 OF PLATS, ON PAGE 19, RECORDS OF KING COUNTY AUDITOR, SITUATED IN THE GiTY OF TUKWiLA, COUNTY OF KM, STATE OF WASHINGTON. DRAWING INDEX T0.0 TITLE SHEET, PROJECT INFO. AL0 FLOOR PLANS 4 NOTES A2.0 WINDOW TYPES, SCHEDULE 4 DETAILS A2.I DOOR TYPES, SCHEDULE 4 DETAILS A22 MISCELLANEOUS DETAILS A2.3 WINDOW FLASHING DETAILS M1.0 LEGENDS, SCHEDULES, ABBR EV, GENERAL NOTES 4 DIM INDEX M2.0 MECHANICAL PLANS AND DETAILS E1.0 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E-mail: Sharyn.Parkerekingcounty.gov ARCHITECT:. S.M. Stamper Architects PLL�C. 4000 Delydge Way SW, Suite 200 Seattle, WA 98106 Fh: 206. 624. 2111 Fax: 206.624.2313 Contact: Jerry Osborn, Melody Leung E-mail: jerry+esmstempsr.com melodyasmstemper com ACOUSTICAL ENGINEER: 554 Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 839. 0819 Fax: 206.835.0824 Contact: Mohamed Ait Allaoua E-mail: mohamedessaacoustica.com MECHANICAL ENGINEER: The Greenbusch Group 1500 West Nickerson St., Suite 201 Seattle, WA 98119 Ph: 206. 318. 0565 Fax: 206. 318. 0641 Contact: Dylan Turner E-mail: DylanTegreenbusthcom ELECTRICAL ENGINEER: Tres West Engineers 2102 842nd Street, Suite 301 Tacoma, WA 98409 Ph: 253, 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E-mail: bcretreswestcom REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E, Suite 100 Seattle, WA 9802 Ph: 206. 232. 9639 Fax: 206.162. 4180 Contact: Tim Ogden E-mail, tim ogdenepbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. *200 Boston, MA 02114 Contact: Tim Fenlason, Cynthia Maeda. E-mail: tfeniasonajonespaynecom CMaeda+ jonespaynecom STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206. 622. 4580 Fax: 206.622.0422 Contact Ron Martinson E-mail: ronmapsm-engineers.com RECEIVED CITY OF TUKWIL FEB 0 7 2013 PERMIT CENTER VICINITY MAP (NTS) 13O9 S . M.STEMPER ARCHITECTS 4 Professional Limited Liability .Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2673 OCTOBER 19, 2012 0810.03.2329 0 ce qC J 0 z ce w z z 0 0 0 z z w 0 f w w ce w O z LL 0 F-- z rt AIP NUMBER 3-53-0058-045 z 0 0 DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP PROJECT INFORMATION, DRAWING INDEX, DIRECTORY T0.0 081 0.03.2329 ESEOROCM 2 20" x 20" EXIST. ATTIC ACCESS PANEL CLOSET CLOSET 13iATH n KITCHEN ESEIDROOM SPECIAL NOTES: 1. ASBESTOS CONTAINNG MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEI1ENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01 1101 AND 02 82 00 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT 71-115 RESIDENCE. REFER TO SECTION 01 11 01 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. 3. REFERENCE 5/A22 FOR SMOKE/ CARBON MONOXIDE DETECTOR INSTALLATION DETAIL. 4. SURPLUS WINDOWS E 4 F TO HOMEOWNER NER. S. SURPLUS DOOR NUMBER 1 TO 44OMEOUNER CARPORT L I VINO ROOM MAIN FLOOR PLAN 114,1_ 1'-O 'DINING ROOM PRIOR TO COMMENCING WITH DEMOLITION A "pre -demo inspection" is required. Contractors shall provide documentation that an "asbestos survey" has been completed. If needed, abatement procedures per "Puget Sound Clean Air Agency" shall be completed and documentation of compliance shall be provided at time of final inspection. GENERAL NOTES I. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPoRAR1LY REMOVE FURNITURE, CONTENTS, WALL 14ANCsINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF tH:SE PGLUM NTS AND RETURN THEM TO THEIR OFleNAL LOCAArtlOC AT THE OF WORK DAILY. 3. HOMEOIUVER 51-IALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RE6 ENCE AND ROOMS IN THE RESIDES FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS. DOORS oR WINDOWS SCHEDULED TO [3E REPLACED SHALL NOT BE ICED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MST OCCUR ONTHESAME DAY BETWEEN &00 AM AND 5:00 Ph 6. DO NOt INSTALL NEW DOORS OR ILJINDOWS WHERE EXISTING WINDOUJ AND DOOR RCIJGH-1 OPENINGS. ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOvE1ED. 'I. ADD SOLID WOOD BLOCKING AT WINDOWS. S. FOLLOW WINPQUJ FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. Z. EXISTING WINDOW COVERINGS MUST BE REINSTALLED CN THE SAME DAY AS COMPLETION OF WINDOW INSTALL. F WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE - 11. ALL WORK AREAS SHALL DE BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MECJ-1. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) 51-ELVlN A5 i EQ'D AND FE -CONSTRUCT SI-lELvINC IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVINCC TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH A5 CLOSELY A5 POSSIBLETO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITI4 THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES: 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED I5Y THE WORK PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS' PRESENT AT VARIOUS LOCATIONS THROLIG TOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS I SWITCHES ON ARC/-IITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. IT, DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK. REFER TO ELECTRICAL FOR TIMER LOCATION IS. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKEOK DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS 5MEET. I3. CONTRACTOR 15 TO VERIFY THAT THERE ARE SUFFICIE+IT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS To SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POIIER OUT** IS EIGHT HOURS. NEER run sE PROVIDED AT RESIDENCE BEFORE S:00 AM 4 AFTER 540 Pit A. WEST ELEVATION 1- 1 381-4" 20ATTIC" 'x 24=0" EXISTtS3. 0" E - - . . . PANEL _ . . . _ . . _ L—. • -/I- -� - r .� \. - • - / /-_/_7 v7=__7 CARPORT I L V I� L V B. NORTH ELEVATION PLAN KEYNOTES 0 DI=MOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY, i EF. WINDOW SCHEDULE. 02DEMOLISH EXISTING WOWS), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, ?RIM, THRESHOLD AND STORM DOOR REP. DOOR SCHEDULE. 3 " INSTALL FIR'EP!_ACE VENT, COORDINATE EXACT LOCATION WITH I-40MEOWNER. ti-,; INSTALL FIREPLACE CAP AT (E) CHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION. INSTALL FER MANUFACTUBER S MITTEN INSTRUCTION.DONOT INSTALL TALL DAMPE2S AT CHIMNEY TOPS SERVINCZERO LEARAWCEF1REBfX=S. C) INSTALL ROOF MOUNTED BAFFLE AT (E) KITCI-IEN EXHAUST. REF. 4/A2.2 FOR DETAIL. 6 COORDINATE CEILING;C*RILL WITH MECHANICAL DOCUMENTS. C) DEMOLISH EXTERIOR WALL AS5EMI31MI Y AS REQUIRED: INSTALL FRES/-1 AIR INTAKE GRILLE. REF. 1/42.2 FOR DETAIL. COORDINATE WITH: MECHANICAL DOCUMENTS. 013LENDINf UNIT LOCATED ADJACENT TO (E)1ATC14 INSTALLED 1N ATTIC, REF. MECH. DOCUMENTS FOR UNIT, REF. ELECT. DOCUMENTS FOR SPEED CONTROL AND DISCONNECT. RIP. 3/422 FOR DETAIL. 9 IN.STALL'PROCABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE WITH MECHANICAL AND ELECTRICAL DOCUMENTS. 10 SURPLUS (E) WINDOW OR DOOR TO HOMEOWNER. REF: SPECIAL NOTES ON SHEET A1.0. (7 -1 -\INSTALL NEW SECONDARY SLIDING GLASS DOOR REF. DOOR SCHEDULE. (E) INTERIOR FLOOR 15 2"-3" 1-11 MER THAN EXTERIORAN I t H L DING. NS ALL NEW 3ECDNDARY GLASS DOOR THRESHOLD LEVELED Wlt (E) GLASS DOOR THRESHOLD. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS 6HALL NOT PAR( IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. ATTIC PLAN 114',_1'-0" '1 C. EAST ELEVATION LEGEND X [1:14 ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR) STORM DOOR REFER TO DOOR 'SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MEC-. FOR UNIT P1-10TO DETAIL EXTERIOR ELEVATION PHOTO VIEW TVP. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1.4 "nil • City of Tukwila BUILDING DIVISION 711 RECEIVED CITY OF TUKWILf FEB 072013 HERMIT CENTER D. SOUTH ELEVATION 111111111111 CABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN, EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. - i MATCH (E) TEXT1JRE AND FAINT ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. REF. MECH. it ELECT. 4 REF. GENERAL NOTE 11 ATTIC INSULATION ATTIC INSULATION DAM INSTALL BATTERY OPERATED SMOKE' DETECTORS INSTALL BATTERY OPERATED SMOKE / CARBON MONQxIPE DETECTORS GAS METER. SOFFIT FOR MEC/ -I TICAL DUCTI143 S.MSTEMPER ARCHITECTS A Profeasional Limited Liability Company 4000 DEL1ID E WAY SW SUITE 200 • SEATTLE, Wk 98108 (208) 824-2777 , FAX (209) 024-2979 OCTOBER 19, 2012 0810.03.2329 z W W 0 0 1— z W Z O J z w W AIP NUMBER 3-53-0058-045 0 0 z Z J DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES A1 .0 0810.03.2329 WINDOW TYPES 1. HORIZONTAL xX SLIDER WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE VV x H TRIM FINISH INT./ EXT. REMARKS DETAIL SET A BEDROOM 1 1 x 2'-1‘," STAN/STAIN REllovE 4 REINSTALL (E) SHUTTERS, SAFETY GLAZING led)1.11RED 1/42z 5 isEpRoctl 1 1 '-l1 x 21- Ion STAIN/STAIN REMOVE 4 REINSTALL (E) SHUTTERS 1/42.0 C BEDROOM 2 1 5' -Il x 2" -ler STAIN/STAIN FEMOVE 4 REINSTALL (E) SHUTTERS 1142.0 a BEDROOM 2 1 3' -lo x 2-10" STAIN/STAN 1/42.0 E LivING RoOTI 1 4I1�1rx 3'-10" STAN/STAN SAFETY GLAZING REQUIRED 1/42D F LIVING ROOM 1 4'-10" x 3'-10" STAIN/STAN SAFETY GLAZING REQUIRED 1/42 T/42.0 G KITCHEN 1 -I0" x 21-11" STAIN/STAIN REMOVE 4 REINSTALL 7E) SHUTTERS, SAFETY GLAZING JD CAREFULLY LIFT (E) WALL UNPERLAYMENT AND WALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAF (E) WALL UNDERLAYMENT OVER PENETRATIoN FLASI-ING. TW AT HEAD A14, JAMBS. REMOvE (E) T-111 SIDING FOR INSTALLATION OF NEW WINDoW ASSEMBLY AND TRIM. REFLAcE OR le INSTALL SIDI AS REQID. MANTAN (E) ccURSING. FAINT MODIFIED SIDING To (E) FRE -PRIMED, GALV SHEET METAL FLASHING IW END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR To 5E SELECTED N THE FIELD Tort- MAT04 (E) TRIM. PRIME ALL SIDES AND PAINT 10 MATCH (E) TRIM. COLOR To BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WNDoW ASSEMBLY REMovE (E) T-111 SIDING FOR INSTALLATION OF NEW WINDoW TRIMS AND REATTACHMENT 0 (E.) SIDING To WINDOW OPENM FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL WINDoW NAILING FLANGE OR SELF ADHERING T'EMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL LNDERLAYMENT. CAULK NEW VERTICAL SIDM JOINTS SET NAIL HEADS FLUSH. PAINT MoDFIED SIDING To NATO -1 (E) SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE TOUCH UF FAINT, AS ear) CONTINUOUS SEALANT, Tn.. Soup Woof, TRIM WD. JAMS LNING. FNISA-I To MATcH (E) SEALANT 4 BACKER ROD SI441 AS NECESSARY FILL GAF Wi BATT INSULATION (E) T -III SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TFRIM. COLOR TO BE FELD DETERMINED BACKER RoD 4 SEALANT ACOUSTICAL WINDOW AS6EM5LY WINDOW HEAD 1 '1 AcoUSTIcAL WINDOW ASSEMBLY BACKER Roc) t SEALANT WINDOW NAIL FLANGE WINDOW JAMB (E) GW5 T0UCI-1 UP PANT, AS REG1'D CoNTINUOUS SF_ALANT, TYF. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAF W/ BATT INSULATION dr/4" TRIM- MATO-1 (E) TRItt PRIME ALL SIDES AND FAINT To MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED MOVE (E) T-111 SIDING FOR INSTALLATION OF NEW LUNDOi.0 ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDNG AS REaD. FAINT MoDIFIED SIDING To MATCH (E) WING. (E) EXTERIOR SI-EATHING SACC ROD 4 SEALANT 3/4" woo SILL SOLO Woo TRIM WINDOW SILL T-111 SIDING 3" = CONTINUOUS SEALANT, TIT. ToUr..44 UP FAINT, AS IREQ1D SELF-A01-1EleING reteRANE (F)GILa WINDOWDETAIL SET TYPICAL WINDOW SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIM ENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'AON WINDOW TYPES, SCHEDULE & DETAILS SHEET. SLOPE E END CLOSURE HEAD FLASHING DETAIL TYP. 3" = 1' - 011 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1 4 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 0 7 2013 PERMIT CENTER 1)4twoLis S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (296) 624-2973 OCTOBER 19,2012 0810.03.2329 re 0 0 ct z 0 0 MPROVEMENTS AIP NUMBER 3-53-0058-045 0 CO DATE OCTOBER 19,2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LIB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2329 DOOR TYPES 4 FLIJSI-I SCW SECONDARY SLIDING W/ RECTANGLE LITE AND GLASS DOOR' 4 PANELS W/ SAFETY GLAZING LU/ SAFETY GLAZING WI OBSERVATION PORT C EXTERIOR' SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET `/ FINISH KNOB / LEVER SET LOCK SET DETAIL SET r ENTRY A 3'-0" x 6'-8" STAN/ STAIN HW-I 1609 DK -4 LOCK -1 1/42.1 1I- DINING ROOM i'3 !'-I1" x 6'-S" STAIN/ STAIN 2/42.1 3 ENTRY G 3'-0" x 6'-b" STAIN/ STAN 1/A2.1 TYPICAL DOOR SCHEDULE NOTES I. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2 SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER; 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 5. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET. SLOPE E M 1" mlrL IS min. i HEMMED EDGE —I 1 [END CLOSURE HEAD FLASHING DETAIL TY'P. 3" = 1' -0'1 REMOVE (E) T -III SIDING FOR INSTALLATION CF NEW DOOR ASSEMBLY AND TRIM. tf PLACE OR RE INSTALL SID1N6_46 REQ'D. MANTAN (E) GOURSIN: . PAINT MODIFIED SIDING TO MATCH (E) 61DINC (E) EXTERIOR SHEATHING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLA51-HNC_ LAP 1E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. PRE -PRIMED, GALY 6I-IEET METAL FLASHING W/ END CLOSURE LNDER SELF -ADHERING MEMBRANE. COLOR TO SE SELECTED IN THE FIELD CONTINUOUS SEALANT SEI4IND 7 BAR FRAME STOW'/ DOOR PER SCHEDULE 2" MIN.. SELF ADI -ERNE MEMBRANE TOUCH LJP PAINT, AS REM) CONTINUOUS SEALANT, TT'P. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATI-ER STRIPPING INSTALLATION CONTINUOUS WEATI- ER- $TRIPPING, DOOR PER SCI4EDULE REMOVE (E) T-1I1_SIDNG FOR INSTALLATION OF NEW DOOR TRIMS AND REATTACHMENT OF (E) SIDING TO DOOR OPENMG FRAMING. LIFT (E) WALL IJNDER..ATENT ANC INSTALL SELF AD4ERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS t SET NAIL HEADS FLUSH. PAINT MODIFIED 6IDN4TO MATCH (E) SIDING (E) T-1113IDN6 DOOR HEAD (E) EXTERIOR 61-1EATI4ING II EXISTING FRAMING CONTNUOUS SEALANT I4IND Z'8AR FRAME STORM DOOR FERE SCHEDULE KEW AS REQUIRED FOR 'WEATHER STRIPPING INSTALLATION CONTNUOUS WEATI IER-STRIPPING JAMB BEYOND 2" MIN. WOOD POOR PER SCWEPULE DOOR SHOE MN DOOR SHEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE SILL N HEAD CF SEALANT .r DOOR JAMB T-111 SIDING 3"= 1'-0 DOOR SILL TOUCH UP PAINT, AS REQ'D CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL CHAP II)/ BATT INSULATION DOOR PER SCHEDULE DOOR DETAIL SET (E) T-111 SIDING PRE -PRIMED, CxALV SHEET METAL FLASKING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. CO -OR TO BE SELECTED N TI4E 'FIELD SELF ADHERING MEMBRANE. TURN DOWN OVER FRONT EDGE OF TRIM. ENSURE NO MEMBRANE IS VISIBLE EaELOW FLASHING EDGE 2X tAFERED CAP TRIM AWAY (E) SIDING TO FACILITATE INSTALLATION OF FLASHING AND DOOR /HEAD ASSEMBLY. TRIM- PAINT TO MATCH (E) TRIM CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR PRAM. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFCz'R INSTRUCTIONS (E) WALL UNDERLAYMENT (E) WALL LIDERLAYMENT (E) EXTERIOR SHEATHING SELF AOIEER(NG MEMBRANE REMOVE (E) SIDING AND REPLACE AS RI=Q'D. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF-ADIERNG MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF PENETRATION FLA61-IINCs. PAINT MODIFIED SIDING TO MATCH (E) SIDING. TVP. AT HEAD AND JAMBS BACKER ROD AND SEALANT TRIM- PAINT TO MATCH (E) TRIM CONTIP4flJ6 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME, PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM TRIM- PANT` TO MATCH (E) TRIM SELF -ADHERING MEMBRANE SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS IUD. TRIM BEYOND DOOR HEAD SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS SEALANT SOLID WOOD LINING (E) PRIMARY SLIDING DOOR ASSS IBLY (E) T-111. SIDING (E) EXTERIOR SHEATHING CARI=RLLY LIFT (E) WALL UNDERLAYMENT. LAP GRADE D WALL UNDERLAYMENT UNDER (E) I.UALL UNDERLAYMENT 2" AND CONTINUE OVER SLI0ING GLASS DOOR FRAME 1/2" MIN BETILEEN PRIMARY MD SECONDARY SLIDING GLASS DOOR FRAMES DOOR JAMB EXISTING SUBSTRATE SOLID WOOD LINING (E) PRIMARY SLIDING GLASS DOOR' (E) SLIDING GLASS DOOR (E; FINISH FLOOR (E) INTERIOR CONC. SLAB. OR (E) ILD. FLOOR FRAMING DOOR SILL T-111 SIDING - DOOR DETAIL SET 3"= 1,-0„ REVIEWED FOR CODE COMPLIANCE APPROVED FEB 14 ,n,i City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA, FEB 0 7 2013 !HERMIT CENTER b .M.STEMPER ARCHITECTS A Prateasivnal Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (2"6)..:624-2973 OCTOBER 19, 2012 081.0.03.2329 0 0 -J z 0 Cez 0 0 Z MPROVEMENTS 0 w 2 w Ct w U 0 z LL r w COW AIP NUMBER 3-53-0058-045 DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP DOOR TYPES, SCHEDULE & DETAILS A2.1 9810.03 232'9 CAREFULLY LFT (E) WALL UNDERLAYMENT AND INSTALL SELF-ADI-IERNG MEMBRANE PENETRATION FLASHING. LAP (E) WALL INDERLAYMENT OVER PENETRATION FLASHING. Tr' AT HEAD Aro Jams. REMOVE (E) T-I1I ID11FOR INSTALLATION OF VENT FIXTURE AND FLASHING. REPLACE OR RE INSTALL SIDING AS Q'ID. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING.. GALV SHEET METAL FLASHING FF. END CAPS UNDER SURFACE MOUNTED REGLET AND CAP FLASHING. PAINT COLOR TO BE SELECTED IN TI -IE FIELD PAINT VENTILATION HOOD, COLOR TO BE SELECTED IN 1-14E FIEL-D EXTERIOR VENTILATION HOOD. REF. MECH.- PAINT NTEROIR Acoust ICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. REPLACEMENT SIDNG AS REQUIRED. EXISTING ACCESS 1-1ATC4-1 REF: ATTIC PLAN FOR LOCATION AIR INTAKE DETAIL AT EXTERIOR (5) WALL UNDERLAYMENT SELF ADHERING MEMBRANE (E) EXTERIOR 5IEATI-IING 2X BLOCKING 2X2 CONTINUOUS BLOCKING, 4 SIDES 2X BLOCKING 3" = 1' - 0" ATTIC EXISTING ROOF (E) IO* FRAMING (E) EAVE VENT. MAY VERY AT EACH PROPERTY. BLOWN IN CELLULOSE INSULATION WITI4 A COMBINED VALUE OF NOT LESS TI4AN R-38 INSULATION Pal (E) WALL FRAMING TIECH UNIT AND pticre- WF MECHANICAL HOLD TIGHT TO (E) FLOOR STRICTURE BELOW DISPLACE INSULATION TO FACILITATE INSTALLATION OF MECHANICAL UNIT, DUCT CONTINUOUS VIBRATION DAMPENING PAD RE: MECHANICAL FREMANUFAACTURED ROOF BAFFLE (BROM- MODEL 634) ExI9TIN DUCTWORK AL Ajl. NAILS WITH ROOF CEMENT NOTE: 1 PREMANUFACTURED ROOF BAFFLE. INSTALL PER MANUFACTURES INSTR.ICTIONS. SEAL SHINGLES TO ROOF CAP ON TOP AND SIDES KITCHEN EXHAUST BAFFLE DETAIL 1 1/2" = 1' - 0" CEILING t)41-0118 4HIMIN BEST 14ERE ACCEPTABLE HERE NOTE: REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. SIDE WALL REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1 4 "11 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIL FEB 0 7 2013 PERMIT CENTER DETECTOR INSTALLATION DETAIL TYP. 3" = 1 - 0" S.MSTEMPER ARCHITECTS A Professional Limited nobility Company 4000 DELRIDGE WAY SW SUITE 2C0 • SEATTLE, WA 88106 (206) 624-2777 • FAX 12011) R.24 -2o73 OCTOBER 19,2012 0810.03.2329 0 z0 uJz KING COUNTY MPROVEMENTS ›- wU)2 w 0 z 0 LLI CO LLI AIP NUMBER 3-53-0058-045 DATE OCTOBER OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT J PROJECT MANAGER ML&TF DRAWN LB&CP MISC. DETAILS A2.2 0810.03.2329 LFT (E) WALL LNDERLAYMENT AWAY LOOSELY' FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TY# NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS REQ'D (E) SIDING NOT SWOUI4 FOR CLARITY. !REPLACE AND OR INSTALL NEIU SIDNG AFTER MEMBRANE FLASHING WAS BEEN INSTALLED. 12" LAP SILL MEt18R4NE FLASHING 2-1/2" OVER (E) BLDG. PAF R AT SILL. EXTEND I" L EYOND R:O. AT EA, END OF SILL. (E) WALL. LINDERLAYMENT AT SILL (E) SHEATHING CUT SILL FLASI-ING TO EIS OF R.O. A5 SHOWY ADHERE MEMBRANE FLASHING TO OUTSIDE FAGS OF WALL SHEAT1-LING I" MIN I.1!2" TYF' �4 !BUTTERFLY CORER FLASHING LIFT (E) BLDG. PARER AWAY LOOSELY FROM (E) SHEATHING At JAMBS AND HEAD. (E) SIDING NOT 51-10(1 FOR CLARITY. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. I=NSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANS. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL WOLFS. REMOVE EXCESS MATERIAL. DO NOT SEAL' FLANGE AT WINDOW SILL (E) WALL NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ't (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMERANE FLASHING WAS BEEN INSTALLED. UNDERLAYMENT AT SILL REMOVED ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL. REPRESENTATIVE OF DISCREPANCIES HEE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. EMEND ANCHORAGE NAILS DO,N OVER NAIL FLANGE, I- EAD ONLY. WINDOW MEMBRANE INSTALLATION SCALE: NTS EDGE OF (E) SIDING. SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOW FOR CLARITY. LAY (E)WALL UNDERLAYMENT BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE (E) S11DNVG BACK I=ROM (E) lam. AS RE= (E) SIDINCa NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW stair* AFTER MEMBRANE FLASHING WAS BEEN INSTALLED. (:I) HEAD FLASHING PREPARATION SCALE: NTS WHERE REQUIRED, TRIM (E) LU4LL UNDERLAYMENTAT HEAD TO PRE ARE FOR INSTALLATION OF 1 -AD FLASHING AND WINDOW TRIM MOLL-al.44 STEPS) (E) WALL UNDERLAYMENT NOTE: REMOVE (E) 5IDFNG SACK FROM (E) R.O. AS REG)'D (E) SIDING NOT SHOWN FORCLARIT'r. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 SEEN INSTALLED. -- GUT JAMB FL4SI-INks TO EDGE CF WINDOW OPENING AS SHOWN, EXTEND 1-112" 1.112" TPP. !BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL ADHERE MEMBRANE FLASHING TO. OUTSIDE FACE OF WALL SHEATHING NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REM) (E) SIDING NOT SHOIIx4 FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL STT. METAL HEAD FLASHVsJ RIDER (E) BLDG PAPER TRIMMED EDGE - INSTALL JAMB FLANGE FLASHING OVER WINDOW' NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB J,,I SCALE NTS NOTE: REMOVE (E) SIDING BACK FROM (E) Ra AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SONG AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. OF (E) SIDING, DIAGRAMATICALLY. (E) SIDING NOT 51-100.N -FOR. CLARITY. O HEAD FLASHING INSTALLATION ALLOW WV CLEARANCE 8ETt1EEN FLASHING ANY:? BOT. EDGE OF (E) SIDING: SCALE: NTS (E) WALL UNDERLAYMENT /1 MEMBRANE FLASHING AT HEAD SCALE NTS CUT 14EAD FLASHING TO EDGE OF WINDOW OPENING AS 51401114. EXTEND 1-1/2" BEYOND RO. AT PLEAD AND JAMBS. ADHERE PENETRATION! FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TPP. EACH SIDE OF WALL) NOTE:'REMOvE (E) SIDING SACK FROM (E) R0. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE ANP QR INSTALL NEW SIDING AFTER MEMBRANE FLASHING WAS BEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. L 0 0 0 WINDOW FLASHING INSTALLATION SCALE: NTS SHEET' METAL HEAD FLASHING (E) SIDING WOOD TRIM INSTALLATION SCALE: NTS (E) BLDG. PAPER BENEATH SIDING INSTALL WD. TRIM: BLITT TIGHT TO TRH -PIED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT SEMEN WINDOUJ' TRIM AND SIDING. LEAVE I/4" -3/S" GAP 5E11.051 LUNDOW TRIM ANP WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: 1: MEMBRANE FLASHING I5 SPECFFIED IN 01 62 00 AS "SELF ADHEARINLG MEMBRANE FLASHING" TYPICALLY REFEREE, TO A5 "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3 DETAILS "5 AND 6" REFER TO MEMPRANLE INSTALLATION AFTER WINDOW 1-146 BEEN SET 1N PLACE, 5I -wimp, AND ANCHORED. 4: DETAILS "1 AND 8" REFER TO SWEET METAL HEAD FLASHING. 5: DETAIL'S REFERS TO WOOD TRIM AND CAULK JOINTS. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 14 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIL FEB 0 7 2013 PERMIT CENTER 1)G-01•0 S.MSTEMPER ARCHITECTS A . Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200• SEATTLE, WA 98106 (2o,) 624-2777 • FAX Pell) 1124-.297a OCTOBER 19, 2012 0810.03.2329 ce 0 cec J 0 cez LU 0 0 0z MPROVEMENT AIP NUMBER 3-53-0058-045 Z 0 N co C9 DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT J'o PROJECT MANAGER ML&TF DRAWN LB & CP WINDOW FLASH ING DETAILS A2.3 031 0.03.2329' \\ \\\ ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL. REPRESENTATIVE OF DISCREPANCIES HEE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. EMEND ANCHORAGE NAILS DO,N OVER NAIL FLANGE, I- EAD ONLY. WINDOW MEMBRANE INSTALLATION SCALE: NTS EDGE OF (E) SIDING. SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOW FOR CLARITY. LAY (E)WALL UNDERLAYMENT BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE (E) S11DNVG BACK I=ROM (E) lam. AS RE= (E) SIDINCa NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW stair* AFTER MEMBRANE FLASHING WAS BEEN INSTALLED. (:I) HEAD FLASHING PREPARATION SCALE: NTS WHERE REQUIRED, TRIM (E) LU4LL UNDERLAYMENTAT HEAD TO PRE ARE FOR INSTALLATION OF 1 -AD FLASHING AND WINDOW TRIM MOLL-al.44 STEPS) (E) WALL UNDERLAYMENT NOTE: REMOVE (E) 5IDFNG SACK FROM (E) R.O. AS REG)'D (E) SIDING NOT SHOWN FORCLARIT'r. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 SEEN INSTALLED. -- GUT JAMB FL4SI-INks TO EDGE CF WINDOW OPENING AS SHOWN, EXTEND 1-112" 1.112" TPP. !BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL ADHERE MEMBRANE FLASHING TO. OUTSIDE FACE OF WALL SHEATHING NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REM) (E) SIDING NOT SHOIIx4 FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL STT. METAL HEAD FLASHVsJ RIDER (E) BLDG PAPER TRIMMED EDGE - INSTALL JAMB FLANGE FLASHING OVER WINDOW' NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB J,,I SCALE NTS NOTE: REMOVE (E) SIDING BACK FROM (E) Ra AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SONG AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. OF (E) SIDING, DIAGRAMATICALLY. (E) SIDING NOT 51-100.N -FOR. CLARITY. O HEAD FLASHING INSTALLATION ALLOW WV CLEARANCE 8ETt1EEN FLASHING ANY:? BOT. EDGE OF (E) SIDING: SCALE: NTS (E) WALL UNDERLAYMENT /1 MEMBRANE FLASHING AT HEAD SCALE NTS CUT 14EAD FLASHING TO EDGE OF WINDOW OPENING AS 51401114. EXTEND 1-1/2" BEYOND RO. AT PLEAD AND JAMBS. ADHERE PENETRATION! FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TPP. EACH SIDE OF WALL) NOTE:'REMOvE (E) SIDING SACK FROM (E) R0. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE ANP QR INSTALL NEW SIDING AFTER MEMBRANE FLASHING WAS BEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. L 0 0 0 WINDOW FLASHING INSTALLATION SCALE: NTS SHEET' METAL HEAD FLASHING (E) SIDING WOOD TRIM INSTALLATION SCALE: NTS (E) BLDG. PAPER BENEATH SIDING INSTALL WD. TRIM: BLITT TIGHT TO TRH -PIED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT SEMEN WINDOUJ' TRIM AND SIDING. LEAVE I/4" -3/S" GAP 5E11.051 LUNDOW TRIM ANP WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: 1: MEMBRANE FLASHING I5 SPECFFIED IN 01 62 00 AS "SELF ADHEARINLG MEMBRANE FLASHING" TYPICALLY REFEREE, TO A5 "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3 DETAILS "5 AND 6" REFER TO MEMPRANLE INSTALLATION AFTER WINDOW 1-146 BEEN SET 1N PLACE, 5I -wimp, AND ANCHORED. 4: DETAILS "1 AND 8" REFER TO SWEET METAL HEAD FLASHING. 5: DETAIL'S REFERS TO WOOD TRIM AND CAULK JOINTS. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 14 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIL FEB 0 7 2013 PERMIT CENTER 1)G-01•0 S.MSTEMPER ARCHITECTS A . Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200• SEATTLE, WA 98106 (2o,) 624-2777 • FAX Pell) 1124-.297a OCTOBER 19, 2012 0810.03.2329 ce 0 cec J 0 cez LU 0 0 0z MPROVEMENT AIP NUMBER 3-53-0058-045 Z 0 N co C9 DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT J'o PROJECT MANAGER ML&TF DRAWN LB & CP WINDOW FLASH ING DETAILS A2.3 031 0.03.2329' ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTU CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF READ RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR w WB W / WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH. EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS SEATTLE RESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL MEE OR XX 0 X/Y "r///////A DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE. ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY UNE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS AL REPRESENTATIVE. COORDINATE MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL N N THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULA11ON SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS. PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. R 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT,. WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE REFERENCE ONLY. LOCATE FOR THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3'-O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL ABBE. -X XXX DN DN UP I f + Imm-m4C + r + -0 0-I- 0 -, 00- .L. 4 - UP VD RA/EA RG SA SA RA/EA SD EA DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH CD 0 R CD THERMOSTAT EQUIP IDS EQUIPMENT LOCATION MOD NG NG 3 0 • A MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL/ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS _ FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS PHASE DESCRIPTION VOLTS PH 32"Lx12.25"Wx8.5"H 76 120 1 23 26 23 26 N/A 23 26 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" CEILING X 1, 2, 4 X 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 140 .5" WG 32"Lx12.25"Wx8.5"H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 2 SG -1 140 <.08" WG 8" 8" CEILING ALLGRILLE 1, 2, 4 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2. 3,4 RG -1 25 <.08" WG 4" 4" CEILING DECO 1, 2, 4 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 5. BASIS OF DESIGN: SHOEMAKER 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE A. OR APPROVED EQUAL. 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 6. PROVIDE WITH AN OPPOSED BLADE DAMPER 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. WAC RESIDENCE CODE FLOOR AREA (SQ. FT.) NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2329 970 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51-51-1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R-8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING R-8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R-8 1,3 IN CEMENT SLAB OR IN GROUND R-5 1.3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULA11ON MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 011101 AND 028200 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. BV -1 SWITCH HOURS OF OPERATION SET BV -1 SWITCH TO OPERATE 1 OF EVERY 2 HOURS. RECEIVED CITY OF TUKWILA FEB 0 7 2013 PERMIT CENTER MECHANICAL VENTILATION CALCULATION PER SRC M1508.3 QF = QR / (&EGR X F) QR = (FROM TABLE 1508.2) 4a acEGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1/2) = 90 CFM D(3 -o4 8 SEPARATE PERMIT AND APPROVAL REQUIRED EXPIRES: 9/08/2014 S.M.STEMPER ARCHITECTS A Psufeerional Llntitted Ltatbillt7 Campng7 4000 DEL IDGE WAY SW SUITE 200 • RATTLE. WA 08106 (206) 624-2777 Fail (206) 624 -eon THE GREENBUSCH GROUP, INC AI OU3 lcM,_ /MO/ VIKO a 2102062001.o199JFFERIN6 1900 rE3r s9EU IsIE 201 SEAM. 9N NM (206) 376-06ee (206) 376-0641 FAX AIP NUMBER 3-53-0058-45 TUKWILA WASHINGTON DATE 09/10/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER 00 DRAVVN JA, DT LEGENDS, Sr SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 081003.2329 BEDROOM 2 BATH 20" x 20" EXIST., ATTIC ACCESS PANEL CLOSET LOSET SEE M2.0 TYP ALL CEILING GRILLES KITCHEN BEDROOM DINING ROOM MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1'_0" RETURN AIR DUCT HOLD TIGHT TO STRUCTURE OUTSIDE AIR DUCT MOTOR ACCESS FILTERS ACCESS SUPPLY DUCT COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. BV -1 INSTALLATION DETAIL SCALE: NONE I 4"O DN II 20" x 20" EXIST. I ATTIC ACCESS - 4 ------ I 1 PANEL LL _ ATTIC MECHANICAL PLAN SHEETMETAL TRANSITION TO WALL CAP NECK SIZE DUCT PER PLAN CAULK 2X BLOCKING 2X BLOCKING FOAM BACKER ROD WALL CAP SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS. �WALL CAP DETAIL SCALE: NONE r NORTH DN SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE 2X BLOCKING SLEEVE AND ESCUTCHEON GRILLE DRAWING NOTES: 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SRC M1508.6.6. 2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. FLAG NOTES: 13V-1 AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 260010. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER SRC M1508.6.4. COORDINATE FINAL SWITCH LOCATION WITH HOMEOWNER. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE FOAM BACKER ROD CAULK 2X BLOCKING FLOOR OR CEILING JOIST CEILING NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEILING GRILLE DETAIL SCALE: NONE SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED CITY OF TUKWILA FEB 0 7 2013 PERMIT CENTER I EXPIRES: 9/08/2014 S.M. STEMPER ARCHITECTS A Profsaaional Ilsnitad Lialditj Companx 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE,. WA 98106 (206) —8777 . FAX (806) 624--6678 THE GREENBUSCH GROUP, INC Aoou woo *MECINICAL oaNEEnw) 110) VEX I ON EMT ME 101 SFAUE, WA MI6 too 370-0069 (206) 376-0e41 FAX 0810.032329 MPROVEMENTS 0 co RESIDENTIAL AIRCR AEP NUMBER 3-53-0058-45 ILA WASHINGTON DATE 09/10/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL PLANS AND DETAILS M2.0 0810.03.2329 `/ • 4.2,C) LOCATION: SES T AA4P with MAIN EXISTING LOAD EXISTING LOAD EXSTI NG LOAD EXISTING LOAD µµ EXISTING`LOAD XI s -n NG LOAD EXISTING LOAD .... EXISTI SIG LOAD E>3STIN3 LOAD EXISTING LO EXISTINGLOAD EXISTING LOAD EXISTING LOAD s'n NG L.DA,D Eis-nrsq. LOAD.. .. , EN STING LOAD EXISTING LOAD.H. EXISTING LOAD EN STING LOAD EXISTING LOAD EXISTING LoAp EXISTING LOAD EXISTING LGA EXISTING LOAD BLENDING UNIT SPACE .:.... SPACE SPACE :....... ..... SPACE SPACE: SPACE SPACE SPACE .... SPACE. SPACE [ ISOLAATED GROUND SUS RAINI1GHT NENIA 3R ENCLOSURE REMARKS: 0 FEED THRU LUGS 0 DOUBLE LUGS NORTH ELEcTRIcAL LEGEND SYMOL IDEWRIPTIM SYMBOL - ION mai LIGHTING OR POWER PANEL EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPEgFlC REQUIREMENTS. 0 BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT NE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. t2 AWIG, 1/210. mu INT OR RIGID STEEL 1 INDICATES EQUIP GNI)., 1 INDICATES ISOLATED GROUND. MAST, WEATHERHEAD DAMPER CONNECTION D Di NON-FUSED' DISCONNECT S ITCH TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS - BRANCH CIRCUIT HOME RUN ELECTRICAL METER `-i? i SMOKE DETECTOR TIMER OPERATED SWITCH —°- -- - - AERIAL SERVICE CONDUCTORS, COORDINATE WITH umurt CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT - +. THERMCSTAT LNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DEIECTOR ELECTRICAL -PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE 'INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER` 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE' SHEET ROCK, TAPE AND RE AND PAINT TO F1LL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT, COORDINATE WORK WITH' MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. ATTC. SEE FLOOR PLANS FOR LOCATIONS OF BLENDING UNITS AND TIMER SWITCHES MP 2#12NMB + G, OR EQUAL RECEIVED CITY OF TUKWILA FEB 0 7 2013 ?ERIUMIT CENTER Q 13-0 �t 8 ELECTRICAL ONE -LINE NOT TO SCALE SEPARATE PERMIT AND AP P ROVAL REOJRED S.MSTEMPER ARCHITECTS 9 Professional Limited liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (BO6) 524-2777 • PAX X266) 624-2973 111 INGINEEM UM w SMITE or rrr Sri M TA N ::1NOM r. 0810.03.2329 ce 0 J 0 Z w Z Z 0 0 Z MPROVEMENTS AIP NUMBER 5-53-0058-045 DATE SEPT 17, 2012 ISSUED 95% PROJECT ENGINEER CHL PROJECT MANAGER BCR D RAVUN BCR FLOOR PLANS NOTES E1 .0 081 0.03.2329