HomeMy WebLinkAboutPermit D13-048 - SPADONI RESIDENCE - REMODELSPADONI RESIDENCE
5710 S 133 ST
D13-048
City ofii'ukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
Parcel No.: 2172000330
Address: 5710 S 133 ST TUKW
Suite No:
Project Name: SPADONI RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D13-048
Issue Date: 03/19/2013
Permit Expires On: 09/15/2013
Owner:
Name: SPADONI MARK A
Address: 5710 S 133RD ST , TUKVVILA WA 98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RDS , SEATTLE WA 98108
Contractor:
Name: S K M CONSTRUCTION INC
Address: 14415 SE 143 PL , RENTON, WA 98059
Contractor License No: SKMCOI*052L3
Lender:
Name:
Address:
Phone: 206-296-7437
Phone: 425 235-5569
Expiration Date: 12/30/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $18,756.00 Fees Collected: $748.15
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
**continued on next page**
doc: IBC -7/10
D13-048 Printed: 03-19-2013
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non -Profit: N
Water Main Extension: Private: Public:
Water Meter:
Permit Center Authorized Signature:
N
Date: P- `(3
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature:
1-io`fth
Date: 31E111 -2)
Print Name: C. a'1�'-� K i\f\rx-( C)(.\
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431-3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D13-048 Printed: 03-19-2013
this requirement.
11111 411
7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D13-048 Printed: 03-19-2013
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Building Permit No. b 'U
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.: 2172000330
Site Address: 5710 S 133rd St
Tenant Name:
Mark Spadoni
Suite Number:
Property Owners Name: Mark Spadoni
Mailing Address: 5710 S 133rd St
Floor:
New Tenant: 0 Yes ® ..No
Tukwila
WA
98178
City
State
Zip
CONTACT PERSON who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Day Telephone: (206) 296-7437
Mailing Address: 7277 Perimeter Road South Seattle WA 98108
E -Mail Address: Sharyn.Parker@kingcounty.gov
City State
Fax Number: (206) 269-7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Contact Person: Jesse Holgate
Seattle
WA 98106
or Timothy Fenlason
E -Mail Address: jesse@smstemper.com/tfenlason@jonespayne.cce
City State
Day Telephone: (206) 624-2777
Fax Number: (206) 624-2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
Fax Number:
E -Mail Address:
H:\Applications\Fonns-Applications On Line\2009 Applications\I-2009 - Permit Application.doc
Revised: 1-2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price): $ 18,756 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? 0 Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
0 Sprinklers 0 Automatic Fire Alarm m None
❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Fotms-Applications On Ling \2009 Applications\I-2009 - Permit Apphcation.doc
Revised: 1-2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1st Floor
979
2nd Floor
3`d Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
•
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? 0 Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
0 Sprinklers 0 Automatic Fire Alarm m None
❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Fotms-Applications On Ling \2009 Applications\I-2009 - Permit Apphcation.doc
Revised: 1-2009
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In allcases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is, issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN' ._,,�. - • •
�i�
Signature:
Date: 2/Z(/)
Print Name J. Fenlason, SM Stemper Architects, PLLCDay Telephone: (206) 624-2777
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
City
State
Zip
Date Application Accepted:
Date Application Expires:
Staff Initials:
H:\ApplicationsTottms-Applications On Line\2009 Applications\I-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 6 of6
City o'ukwilar
Department of Commun ity Development
6300 Southcerter Boulevard, Suite 4100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: htw:/tvww. ci. tulnvila. wa. us
SET RECEIPT
Copy Reprinted on 02-19-2013 at 09:09:21 02/19/2013
RECEIPT NO: R13-00837
Initials: WER
Payment Date: 02/19/2013
User ID: 1655 Total Payment: 5,833.28
Payee: PAMELA K KUEHL (BY PHONE)
SET ID: 020713 SET NAME: KING COUNTY SOUND ABATEMENT
SET TRANSACTIONS:
Set Member Amount
D13-045 811.18
D13-046 842.70
D13-047 716.64
D13-048 748.15
D13-049 622.10
D13-050 1,067.51
M13-038 167.70
M13-039 167.70
M13-040 167.70
M13-041 167.70
M13-042 167.70
M13-043 186.50
TOTAL: -'
TRANSACTION LIST:
Type Method Description
Amount
Payment Credit C VISA 5,833.28
TOTAL: 5,833.28
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES 000.322.100 2,897.75
MECHANICAL - RES 000.322.102.00.0 1,025.00
PLAN CHECK - RES 000.345.830 1,883.53
STATE BUILDING SURCHARGE 640.237.114 —2i0
TOTAL:
5,833.28
INSPECTION RECORD
Retain a copy with permit
Dt3—O4'
INSP CTION`N0. PERMIT NO. C-'" V `
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:Type
5 (��_ o o A! 2e3
of Inspection: o
(Loa Ifr- ` n.s .S e vi -L
Address: c Q
DaoCall`d i 0/�b. /
c,J, ,
(O (3Z
J S
Special Instructions:
Date Wanted:. f -'" a.mi
S'1 '(Z p.m.
Requester:
PhongtS — 63.1 ` 22, Z-/
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
•
•
D p I { i t'o lkorcA
(Th
Inspettor`._
A li
Date: 5
(3
REINSPECTION FEE REQUIR +: Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Gale Contractor Services
A Masco Contractor Services Company
16910 59th Ave. NE, Suite 100
Arlington, WA 98223
Installed Insulation Certificate
"We certify that insulation material listed here and installed at the following residence
surrounding conditioned space meet applicable federal, state, and local specifications."
CITRECEIVED
KWI
APR 302013
PERMIT CENTER
Loose Fill Kraft Unfaced Foil Foam Cellulose R -Value Thickness No. Pkgs Coverage Area
Ceilings n 0 [� 0 R-38 12 3/4" 16
GEW 0 = D C7 0 0
Walls p p O = O O
Basement =ED ED= = Q
Crawlspace 0 ED[] 0 E] 0
Contractor
Laura Halgren
(Signature)
Address or Lot Number 5710 S 133RD ST
City, ST, Zip: Tukwila WA 98128
Title
Office Manager
Date Installed: April 29, 2013
pE
PLAN R VI
r
NG SLIP
ACTIVITY NUMBER: D13-048
PROJECT NAME: SPADONI RESIDENCE
SITE ADDRESS: 5710 S 133 ST
X Original Plan Submittal Response to Incomplete Letter #
DATE: 02-07-13
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
�t3tr
421dingt&on 4111
Public Works ❑
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02-12-13
Complete Incomplete ❑
Comments:
Not Applicable
Permit Center Use Only,
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
TUES/THURS ROUTING:
Please RouteIs,&] Structural Review Required ❑ No further Review Required
REVIEWER'S INITIALS:
C
DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
DUE DATE: 03-12-13
Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Documents/routing slip.doc
2-28-02
Contractors or Tradespeople Prfer Friendly Page
•
General/Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name 5 K M CONSTRUCTION INC UBI No. 601577401
Phone 4252355569 Status Active
Address 14415 Se 143Rd Pl License No. SKMCOI*052L3
Suite/Apt. License Type Construction Contractor
City Renton Effective Date 6/23/1995
State WA Expiration Date 12/30/2013
Zip 98059 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
SKMCO"093L6SKM
CONSTRUCTION
Construction
Contractor
General
Unused
6/26/1991
6/17/1995
Archived
SKMINI'976QL
S K M INDUSTRIES
INC
Construction
Contractor
General
Unused
11/13/2003
12/6/2009
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
MORRISON, SHEILA K
President
06/23/1995
Bond Amount
MARKET SANDERS
Agent
06/23/1995
06/25/2001
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
5
FIRST NATL INS CO OF
AMERICA
6695979
06/17/2010
Until Cancelled
$12,000.0004/26/2010
08/20/2012
4
DEVELOPERS SURETY
Et INDEM CO
188889C
12/30/2001
Until Cancelled
08/01/2010
$12,000.0012/05/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
16
James River Ins
000495931
08/21/2012
08/21/2013
$1,000,000.00
08/20/2012
15
James River Ins
Co
00049593
08/21/2011
08/21/2012
$1,000,000.0008/18/2011
14
COLONY INS CO
EPK300402
08/21/2010
08/21/2011
$1,000,000.0008/20/2010
13
CENTURY
SURETY CO
CCP616634
08/21/2009
08/21/2010
$1,000,000.0001
/20/2010
12
AMERICAN
STATES INS CO
01CH6810051
01/25/2009
01/25/2010
$1,000,000.0001/23/2009
11
AMERICAN
STATES INS CO
01CH6810051
12/30/2008
01/25/2009
$1,000,000.00
12/23/2008
10
AMERICAN
STATES INS CO
01CH6810051
12/30/2007
12/30/2008
$1,000,000.00
12/07/2007
9
AMERICAN
STATES INS CO
01CD87273820
12/30/2006
12/30/2007
$1,000,000.00
12/19/2006
httnc•//fnrtrecc wa unv/lni/hhin/Print.asnx
03/19/2013
KING COUNTY INTERNATIONAL A
1
RPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00784C12 BID PACKAGE M-37
3-53-0058-045
SCOPE OF WORK
RENOVATION OF RESIDENCE TO REDUCE NOiSE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE
NTUDES ALL INFORMATION. IN THE DRAWINGS AND
MECHANICAL INCLUpINCx 131,17 NOT LIMITED TO
SPECIFICATIONS
APPLICABLE
YES NO
1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL -FRAMED ACOUSTICAL WINDOWS.
X
2. CUT DOWN QF WINDOWS TQ COMPLY WITH EGRESS REQUIREMENTS.
X
3. WILL OF EXISTING OPENINGS.
X
4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITI-I NEW ACOUSTICAL DOORS.
X
5. INSTALLATION OF STORM DOORS.
X
6. INSTALLATION OF SECONDARY SLIMING GLASS DOORS.
X
1. INSTALLATION OF SECONDARY SKYLIGHTS.
X
8. INSTALLATION OF PET DOORS.
X
9. INSTALLATION OF FIREPLACE FRESH AiR VENT.
X
l0. INSTALLATION OF CHIMNEY CAP.
X
11 REGULATED MATERIALS ABATEMENT.
X
12. ATTIC VENT BAFFLES.
X
13. INSTALLATION OF ATTIC INSULATION.
X
14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND
ASSOCIATED DUCTING.
X
15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND
ASSOCIATED DUCTING.
X
16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION.
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCHITECTURAL MODIFICATIONS.
X
18. INSTALLATION OF SMOKE DETECTORS.
X
19. NEW ELECTRICAL PANEL / SERVICE.
X
20. KNOB AND TUBE WIRING
X
FEL COPY
Permit No.
4 8
PI-~ r-v!aw approval is subject to errors and omissions.
c •'`" v truction documents does not authc:Yize
t; ‘o_ ,; iy adopted code or ordinance. Receipt
o; F` d Copy and conditions is acnowledged:
By
Date:
City Of Tukwila
BUI _DING DIVISION
Re, iSIONS
No cS7ore's PIS !i hr? m7 e to the scope
cf t ^r'c I lithou+ prior Dnp prov21 of
TL;;., -;:!a Building Divi^ c°i.
will require nsw Wan submittal
Ge'd:tional pian Ce'I! • '1 fa,
FOR:
r`,"Lchanicai
cctrical
��I tubing
'!I as Piping
of Tukwila
DiVIczION
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of Seattle, WA
APPLICABLE CODES:
2009 International Residential Code,
Interna tlona l Fire Code,
International Mechanical Code
2112000330
ZONING: SF1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
V B NON SPRINKLERE3
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 14 ,r,,,
City of Tukwila
BUILDING DIVISION
LEGAL DESCRIPTION:
TRACT 65 OF EAST RIVERTON GARDEN TRACTS NO. 2, AS PER PLAT RECORDED IN VOLUME 12 OF PLATS, ON PAGE 19,
RECORDS OF KING COUNTY AUDITOR, SITUATED IN THE GiTY OF TUKWiLA, COUNTY OF KM, STATE OF WASHINGTON.
DRAWING INDEX
T0.0 TITLE SHEET, PROJECT INFO.
AL0 FLOOR PLANS 4 NOTES
A2.0 WINDOW TYPES, SCHEDULE 4 DETAILS
A2.I DOOR TYPES, SCHEDULE 4 DETAILS
A22 MISCELLANEOUS DETAILS
A2.3 WINDOW FLASHING DETAILS
M1.0 LEGENDS, SCHEDULES, ABBR EV, GENERAL NOTES 4 DIM INDEX
M2.0 MECHANICAL PLANS AND DETAILS
E1.0 ELECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206.296.0190
Contact: Sharyn Parker
E-mail: Sharyn.Parkerekingcounty.gov
ARCHITECT:.
S.M. Stamper Architects PLL�C.
4000 Delydge Way SW, Suite 200
Seattle, WA 98106
Fh: 206. 624. 2111
Fax: 206.624.2313
Contact: Jerry Osborn, Melody Leung
E-mail: jerry+esmstempsr.com
melodyasmstemper com
ACOUSTICAL ENGINEER:
554 Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206. 839. 0819
Fax: 206.835.0824
Contact: Mohamed Ait Allaoua
E-mail: mohamedessaacoustica.com
MECHANICAL ENGINEER:
The Greenbusch Group
1500 West Nickerson St., Suite 201
Seattle, WA 98119
Ph: 206. 318. 0565
Fax: 206. 318. 0641
Contact: Dylan Turner
E-mail: DylanTegreenbusthcom
ELECTRICAL ENGINEER:
Tres West Engineers
2102 842nd Street, Suite 301
Tacoma, WA 98409
Ph: 253, 412. 3300
Fax: 253.412.3463
Contact: Brent Rollins
E-mail: bcretreswestcom
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E, Suite 100
Seattle, WA 9802
Ph: 206. 232. 9639
Fax: 206.162. 4180
Contact: Tim Ogden
E-mail, tim ogdenepbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. *200
Boston, MA 02114
Contact: Tim Fenlason,
Cynthia Maeda.
E-mail: tfeniasonajonespaynecom
CMaeda+ jonespaynecom
STRUCTURAL ENGINEER:
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 98121
Ph: 206. 622. 4580
Fax: 206.622.0422
Contact Ron Martinson
E-mail: ronmapsm-engineers.com
RECEIVED
CITY OF TUKWIL
FEB 0 7 2013
PERMIT CENTER
VICINITY MAP (NTS)
13O9
S . M.STEMPER
ARCHITECTS
4 Professional Limited Liability .Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2673
OCTOBER 19, 2012
0810.03.2329
0
ce
qC
J
0
z
ce
w
z
z
0
0
0
z
z
w
0
f
w
w
ce
w
O
z
LL
0
F--
z
rt
AIP NUMBER
3-53-0058-045
z
0
0
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
PROJECT
INFORMATION,
DRAWING
INDEX,
DIRECTORY
T0.0
081 0.03.2329
ESEOROCM
2
20" x 20" EXIST.
ATTIC ACCESS
PANEL
CLOSET
CLOSET
13iATH
n
KITCHEN
ESEIDROOM
SPECIAL NOTES:
1. ASBESTOS CONTAINNG MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEI1ENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01 1101 AND 02 82 00 FOR
REGULATED MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT 71-115 RESIDENCE. REFER TO SECTION 01 11 01
AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
3. REFERENCE 5/A22 FOR SMOKE/ CARBON MONOXIDE DETECTOR
INSTALLATION DETAIL.
4. SURPLUS WINDOWS E 4 F TO HOMEOWNER
NER.
S. SURPLUS DOOR NUMBER 1 TO 44OMEOUNER
CARPORT
L I VINO
ROOM
MAIN FLOOR PLAN
114,1_ 1'-O
'DINING
ROOM
PRIOR TO COMMENCING WITH DEMOLITION
A "pre -demo inspection" is required.
Contractors shall provide documentation that
an "asbestos survey" has been completed. If
needed, abatement procedures per "Puget
Sound Clean Air Agency" shall be completed
and documentation of compliance shall be
provided at time of final inspection.
GENERAL NOTES
I. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPoRAR1LY REMOVE FURNITURE, CONTENTS, WALL 14ANCsINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
tH:SE PGLUM NTS AND RETURN THEM TO THEIR OFleNAL LOCAArtlOC AT THE OF WORK DAILY.
3. HOMEOIUVER 51-IALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM RESIDENCE FROM 5:00 PM TO 8:00 AM EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RE6 ENCE AND ROOMS IN THE RESIDES FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS.
DOORS oR WINDOWS SCHEDULED TO [3E REPLACED SHALL NOT BE ICED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND/OR WINDOW MST OCCUR ONTHESAME DAY
BETWEEN &00 AM AND 5:00
Ph
6. DO NOt INSTALL NEW DOORS OR ILJINDOWS WHERE EXISTING WINDOUJ AND DOOR RCIJGH-1 OPENINGS. ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOvE1ED.
'I. ADD SOLID WOOD BLOCKING AT WINDOWS.
S. FOLLOW WINPQUJ FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
Z. EXISTING WINDOW COVERINGS MUST BE REINSTALLED CN THE SAME DAY AS COMPLETION OF WINDOW INSTALL. F WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE -
11. ALL WORK AREAS SHALL DE BROOM -CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND/OR MECJ-1. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) 51-ELVlN A5 i EQ'D AND FE -CONSTRUCT
SI-lELvINC IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVINCC TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH A5 CLOSELY A5 POSSIBLETO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITI4 THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES:
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED I5Y THE WORK PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS' PRESENT AT VARIOUS LOCATIONS THROLIG TOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PANELS, DUCTS I SWITCHES ON ARC/-IITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
IT, DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK. REFER TO ELECTRICAL
FOR TIMER LOCATION
IS. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKEOK DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS 5MEET.
I3. CONTRACTOR 15 TO VERIFY THAT THERE ARE SUFFICIE+IT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS To SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20. MAXIMUM POIIER OUT** IS EIGHT HOURS. NEER run sE PROVIDED AT RESIDENCE BEFORE S:00 AM 4 AFTER 540 Pit
A. WEST ELEVATION
1-
1
381-4"
20ATTIC" 'x 24=0" EXISTtS3.
0" E - - . . .
PANEL _ . . . _ . . _
L—.
•
-/I- -� -
r
.� \.
-
•
-
/ /-_/_7 v7=__7
CARPORT
I L
V I� L
V
B. NORTH ELEVATION
PLAN KEYNOTES
0 DI=MOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY, i EF. WINDOW SCHEDULE.
02DEMOLISH EXISTING WOWS), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, ?RIM, THRESHOLD AND
STORM DOOR REP. DOOR SCHEDULE.
3 " INSTALL FIR'EP!_ACE VENT, COORDINATE EXACT LOCATION WITH I-40MEOWNER.
ti-,; INSTALL FIREPLACE CAP AT (E) CHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION. INSTALL FER
MANUFACTUBER S MITTEN INSTRUCTION.DONOT INSTALL TALL DAMPE2S AT CHIMNEY TOPS SERVINCZERO LEARAWCEF1REBfX=S.
C) INSTALL ROOF MOUNTED BAFFLE AT (E) KITCI-IEN EXHAUST. REF. 4/A2.2 FOR DETAIL.
6 COORDINATE CEILING;C*RILL WITH MECHANICAL DOCUMENTS.
C) DEMOLISH EXTERIOR WALL AS5EMI31MI Y AS REQUIRED: INSTALL FRES/-1 AIR INTAKE GRILLE. REF. 1/42.2 FOR DETAIL. COORDINATE WITH:
MECHANICAL DOCUMENTS.
013LENDINf UNIT LOCATED ADJACENT TO (E)1ATC14 INSTALLED 1N ATTIC, REF. MECH. DOCUMENTS FOR UNIT, REF. ELECT. DOCUMENTS
FOR SPEED CONTROL AND DISCONNECT. RIP. 3/422 FOR DETAIL.
9 IN.STALL'PROCABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE WITH MECHANICAL AND
ELECTRICAL DOCUMENTS.
10 SURPLUS (E) WINDOW OR DOOR TO HOMEOWNER. REF: SPECIAL NOTES ON SHEET A1.0.
(7 -1 -\INSTALL NEW SECONDARY SLIDING GLASS DOOR REF. DOOR SCHEDULE. (E) INTERIOR FLOOR 15 2"-3" 1-11 MER THAN
EXTERIORAN I t H
L DING. NS ALL NEW 3ECDNDARY GLASS DOOR THRESHOLD LEVELED Wlt (E) GLASS DOOR THRESHOLD.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS 6HALL NOT PAR( IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
ATTIC PLAN
114',_1'-0"
'1
C. EAST ELEVATION
LEGEND
X
[1:14
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR) STORM DOOR
REFER TO DOOR 'SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MEC-. FOR UNIT
P1-10TO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
TVP.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 1.4 "nil
•
City of Tukwila
BUILDING DIVISION
711
RECEIVED
CITY OF TUKWILf
FEB 072013
HERMIT CENTER
D. SOUTH ELEVATION
111111111111
CABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN, EXHAUST BAFFLE
FEATHER TEXTURED CEILING OVER AT A
MIN. OF 24" FROM EDGE OF PATCHING.
- i MATCH (E) TEXT1JRE AND FAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
REF. MECH. it ELECT.
4 REF. GENERAL NOTE 11
ATTIC INSULATION
ATTIC INSULATION DAM
INSTALL BATTERY OPERATED SMOKE'
DETECTORS
INSTALL BATTERY OPERATED SMOKE /
CARBON MONQxIPE DETECTORS
GAS METER.
SOFFIT FOR MEC/ -I TICAL DUCTI143
S.MSTEMPER
ARCHITECTS
A
Profeasional Limited Liability Company
4000 DEL1ID E WAY SW
SUITE 200 • SEATTLE, Wk 98108
(208) 824-2777 , FAX (209) 024-2979
OCTOBER 19, 2012
0810.03.2329
z
W
W
0
0
1—
z
W
Z
O
J
z
w
W
AIP NUMBER
3-53-0058-045
0
0
z
Z
J
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
NOTES
A1 .0
0810.03.2329
WINDOW TYPES
1.
HORIZONTAL
xX SLIDER
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
VV x H
TRIM FINISH
INT./ EXT.
REMARKS
DETAIL
SET
A
BEDROOM 1
1
x 2'-1‘,"
STAN/STAIN
REllovE 4 REINSTALL (E) SHUTTERS, SAFETY GLAZING led)1.11RED
1/42z
5
isEpRoctl 1
1
'-l1 x 21- Ion
STAIN/STAIN
REMOVE 4 REINSTALL (E) SHUTTERS
1/42.0
C
BEDROOM 2
1
5' -Il x 2" -ler
STAIN/STAIN
FEMOVE 4 REINSTALL (E) SHUTTERS
1142.0
a
BEDROOM 2
1
3' -lo x 2-10"
STAIN/STAN
1/42.0
E
LivING RoOTI
1
4I1�1rx 3'-10"
STAN/STAN
SAFETY GLAZING REQUIRED
1/42D
F
LIVING ROOM
1
4'-10" x 3'-10"
STAIN/STAN
SAFETY GLAZING REQUIRED
1/42
T/42.0
G
KITCHEN
1
-I0" x 21-11"
STAIN/STAIN
REMOVE 4 REINSTALL 7E) SHUTTERS, SAFETY GLAZING JD
CAREFULLY LIFT (E) WALL UNPERLAYMENT
AND WALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAF (E) WALL
UNDERLAYMENT OVER PENETRATIoN
FLASI-ING. TW AT HEAD A14, JAMBS.
REMOvE (E) T-111 SIDING FOR
INSTALLATION OF NEW WINDoW
ASSEMBLY AND TRIM. REFLAcE OR le
INSTALL SIDI AS REQID. MANTAN
(E) ccURSING. FAINT MODIFIED SIDING
To (E)
FRE -PRIMED, GALV SHEET METAL
FLASHING IW END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR
To 5E SELECTED N THE FIELD
Tort- MAT04 (E) TRIM. PRIME ALL
SIDES AND PAINT 10 MATCH (E) TRIM.
COLOR To BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WNDoW ASSEMBLY
REMovE (E) T-111 SIDING FOR
INSTALLATION OF NEW WINDoW TRIMS
AND REATTACHMENT 0 (E.) SIDING To
WINDOW OPENM FRAMING. LIFT (E)
WALL UNDERLAYMENT AND INSTALL
WINDoW NAILING FLANGE OR SELF
ADHERING T'EMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER
NAILING FLANGE AND LAP UNDER (E)
WALL LNDERLAYMENT. CAULK NEW
VERTICAL SIDM JOINTS SET NAIL
HEADS FLUSH. PAINT MoDFIED SIDING
To NATO -1 (E) SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING MEMBRANE
TOUCH UF FAINT,
AS ear)
CONTINUOUS
SEALANT, Tn..
Soup Woof, TRIM
WD. JAMS LNING. FNISA-I To
MATcH (E)
SEALANT 4 BACKER ROD
SI441 AS NECESSARY
FILL GAF Wi BATT
INSULATION
(E) T -III SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E)
TFRIM. COLOR TO BE FELD
DETERMINED
BACKER RoD 4 SEALANT
ACOUSTICAL WINDOW AS6EM5LY
WINDOW HEAD
1 '1
AcoUSTIcAL WINDOW ASSEMBLY
BACKER Roc) t SEALANT
WINDOW NAIL FLANGE
WINDOW JAMB
(E) GW5
T0UCI-1 UP PANT,
AS REG1'D
CoNTINUOUS
SF_ALANT, TYF.
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAF W/ BATT
INSULATION
dr/4"
TRIM- MATO-1 (E) TRItt PRIME ALL
SIDES AND FAINT To MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
MOVE (E) T-111 SIDING FOR
INSTALLATION OF NEW LUNDOi.0
ASSEMBLY AND TRIM. REPLACE OR
RE INSTALL SIDNG AS REaD. FAINT
MoDIFIED SIDING To MATCH (E)
WING.
(E) EXTERIOR SI-EATHING
SACC ROD 4
SEALANT
3/4" woo SILL
SOLO Woo TRIM
WINDOW SILL
T-111 SIDING
3" =
CONTINUOUS
SEALANT, TIT.
ToUr..44 UP FAINT,
AS IREQ1D
SELF-A01-1EleING
reteRANE
(F)GILa
WINDOWDETAIL SET
TYPICAL WINDOW SCHEDULE NOTES
I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIM ENSIONS.
3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'AON WINDOW TYPES, SCHEDULE & DETAILS SHEET.
SLOPE
E
END CLOSURE
HEAD FLASHING DETAIL TYP.
3" = 1' - 011
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 1 4
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
PERMIT CENTER
1)4twoLis
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (296) 624-2973
OCTOBER 19,2012
0810.03.2329
re
0
0
ct
z
0
0
MPROVEMENTS
AIP NUMBER
3-53-0058-045
0
CO
DATE
OCTOBER 19,2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LIB&CP
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.2329
DOOR TYPES
4
FLIJSI-I SCW SECONDARY SLIDING
W/ RECTANGLE LITE AND GLASS DOOR'
4 PANELS W/ SAFETY GLAZING
LU/ SAFETY GLAZING
WI OBSERVATION PORT
C
EXTERIOR'
SINGLE LEAF STORM
W/ SAFETY GLAZING
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET `/ FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
r
ENTRY
A
3'-0" x 6'-8"
STAN/ STAIN
HW-I 1609
DK -4
LOCK -1
1/42.1
1I-
DINING ROOM
i'3
!'-I1" x 6'-S"
STAIN/ STAIN
2/42.1
3
ENTRY
G
3'-0" x 6'-b"
STAIN/ STAN
1/A2.1
TYPICAL DOOR SCHEDULE NOTES
I. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN
SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2 SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER;
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS
AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK.
5. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET.
SLOPE
E
M
1" mlrL
IS min.
i
HEMMED EDGE —I 1
[END CLOSURE
HEAD FLASHING DETAIL TY'P.
3" = 1' -0'1
REMOVE (E) T -III SIDING FOR
INSTALLATION CF NEW DOOR ASSEMBLY
AND TRIM. tf PLACE OR RE INSTALL
SID1N6_46 REQ'D. MANTAN (E)
GOURSIN: . PAINT MODIFIED SIDING TO
MATCH (E) 61DINC
(E) EXTERIOR SHEATHING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLA51-HNC_ LAP 1E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
PRE -PRIMED, GALY 6I-IEET METAL
FLASHING W/ END CLOSURE LNDER
SELF -ADHERING MEMBRANE. COLOR
TO SE SELECTED IN THE FIELD
CONTINUOUS SEALANT SEI4IND 7 BAR
FRAME
STOW'/ DOOR PER SCHEDULE
2" MIN..
SELF ADI -ERNE
MEMBRANE
TOUCH LJP PAINT,
AS REM)
CONTINUOUS
SEALANT, TT'P.
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KEW AS REQUIRED FOR
WEATI-ER STRIPPING
INSTALLATION
CONTINUOUS WEATI- ER-
$TRIPPING,
DOOR PER SCI4EDULE
REMOVE (E) T-1I1_SIDNG FOR INSTALLATION
OF NEW DOOR TRIMS AND REATTACHMENT
OF (E) SIDING TO DOOR OPENMG FRAMING.
LIFT (E) WALL IJNDER..ATENT ANC INSTALL
SELF AD4ERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK
NEW VERTICAL SIDING JOINTS t SET NAIL
HEADS FLUSH. PAINT MODIFIED 6IDN4TO
MATCH (E) SIDING
(E) T-1113IDN6
DOOR HEAD
(E) EXTERIOR 61-1EATI4ING
II
EXISTING FRAMING
CONTNUOUS SEALANT I4IND
Z'8AR FRAME
STORM DOOR FERE SCHEDULE
KEW AS REQUIRED FOR 'WEATHER
STRIPPING INSTALLATION
CONTNUOUS WEATI IER-STRIPPING
JAMB BEYOND
2" MIN.
WOOD POOR PER SCWEPULE
DOOR SHOE
MN
DOOR SHEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
SILL N HEAD CF SEALANT
.r
DOOR JAMB
T-111 SIDING
3"= 1'-0
DOOR SILL
TOUCH UP PAINT,
AS REQ'D
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL CHAP II)/ BATT
INSULATION
DOOR PER SCHEDULE
DOOR DETAIL SET
(E) T-111 SIDING
PRE -PRIMED, CxALV SHEET METAL
FLASKING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. CO -OR
TO BE SELECTED N TI4E 'FIELD
SELF ADHERING MEMBRANE. TURN DOWN
OVER FRONT EDGE OF TRIM. ENSURE
NO MEMBRANE IS VISIBLE EaELOW
FLASHING EDGE
2X tAFERED CAP
TRIM AWAY (E) SIDING TO FACILITATE
INSTALLATION OF FLASHING AND DOOR
/HEAD ASSEMBLY.
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING
AROUND PERIMETER OF DOOR PRAM.
PAINT ALL EXPOSED EDGES TO MATCH
(E) TRIM
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFCz'R
INSTRUCTIONS
(E) WALL UNDERLAYMENT
(E) WALL LIDERLAYMENT
(E) EXTERIOR SHEATHING
SELF AOIEER(NG MEMBRANE
REMOVE (E) SIDING AND
REPLACE AS RI=Q'D. LIFT (E)
WALL UNDERLAYMENT AND
INSTALL SELF-ADIERNG
MEMBRANE PENETRATION
FLASHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF
PENETRATION FLA61-IINCs. PAINT
MODIFIED SIDING TO MATCH (E)
SIDING. TVP. AT HEAD AND
JAMBS
BACKER ROD AND SEALANT
TRIM- PAINT TO MATCH (E) TRIM
CONTIP4flJ6 2x SOLID BLOCKING AROUND
PERIMETER OF DOOR FRAME, PAINT ALL
EXPOSED EDGES TO MATCH (E) TRIM
TRIM- PANT` TO MATCH (E) TRIM
SELF -ADHERING MEMBRANE
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
IUD. TRIM BEYOND
DOOR HEAD
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
SEALANT
SOLID WOOD LINING
(E) PRIMARY SLIDING DOOR
ASSS IBLY
(E) T-111. SIDING
(E) EXTERIOR SHEATHING
CARI=RLLY LIFT (E) WALL
UNDERLAYMENT. LAP GRADE D WALL
UNDERLAYMENT UNDER (E) I.UALL
UNDERLAYMENT 2" AND CONTINUE
OVER SLI0ING GLASS DOOR FRAME
1/2" MIN BETILEEN
PRIMARY MD SECONDARY
SLIDING GLASS DOOR FRAMES
DOOR JAMB
EXISTING SUBSTRATE
SOLID WOOD LINING
(E) PRIMARY SLIDING GLASS
DOOR'
(E) SLIDING GLASS
DOOR
(E; FINISH FLOOR
(E) INTERIOR CONC. SLAB.
OR (E) ILD. FLOOR FRAMING
DOOR SILL
T-111 SIDING - DOOR DETAIL SET
3"= 1,-0„
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 14 ,n,i
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA,
FEB 0 7 2013
!HERMIT CENTER
b
.M.STEMPER
ARCHITECTS
A Prateasivnal Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (2"6)..:624-2973
OCTOBER 19, 2012
081.0.03.2329
0
0
-J
z
0
Cez
0
0
Z
MPROVEMENTS
0
w
2
w
Ct
w
U
0
z
LL
r
w
COW
AIP NUMBER
3-53-0058-045
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
9810.03 232'9
CAREFULLY LFT (E) WALL UNDERLAYMENT
AND INSTALL SELF-ADI-IERNG MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
INDERLAYMENT OVER PENETRATION
FLASHING. Tr' AT HEAD Aro Jams.
REMOVE (E) T-I1I ID11FOR
INSTALLATION OF VENT FIXTURE AND
FLASHING. REPLACE OR RE INSTALL
SIDING AS Q'ID. MAINTAIN (E)
COURSING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING..
GALV SHEET METAL
FLASHING FF. END CAPS UNDER
SURFACE MOUNTED REGLET AND CAP
FLASHING. PAINT COLOR TO BE
SELECTED IN TI -IE FIELD
PAINT VENTILATION HOOD,
COLOR TO BE SELECTED IN
1-14E FIEL-D
EXTERIOR VENTILATION HOOD.
REF. MECH.- PAINT NTEROIR
Acoust ICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
REPLACEMENT SIDNG AS REQUIRED.
EXISTING ACCESS 1-1ATC4-1
REF: ATTIC PLAN FOR
LOCATION
AIR INTAKE DETAIL AT EXTERIOR
(5) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
(E) EXTERIOR 5IEATI-IING
2X BLOCKING
2X2 CONTINUOUS BLOCKING,
4 SIDES
2X BLOCKING
3" = 1' - 0"
ATTIC
EXISTING ROOF
(E) IO* FRAMING
(E) EAVE VENT. MAY VERY
AT EACH PROPERTY.
BLOWN IN CELLULOSE
INSULATION WITI4 A COMBINED
VALUE OF NOT LESS TI4AN
R-38
INSULATION Pal
(E) WALL FRAMING
TIECH UNIT AND pticre-
WF MECHANICAL
HOLD TIGHT TO (E)
FLOOR STRICTURE
BELOW
DISPLACE INSULATION TO
FACILITATE INSTALLATION OF
MECHANICAL UNIT, DUCT
CONTINUOUS VIBRATION
DAMPENING PAD RE:
MECHANICAL
FREMANUFAACTURED ROOF
BAFFLE (BROM- MODEL
634)
ExI9TIN DUCTWORK
AL Ajl. NAILS WITH ROOF
CEMENT
NOTE:
1 PREMANUFACTURED ROOF BAFFLE. INSTALL PER
MANUFACTURES INSTR.ICTIONS.
SEAL SHINGLES TO ROOF
CAP ON TOP AND SIDES
KITCHEN EXHAUST BAFFLE DETAIL
1 1/2" = 1' - 0"
CEILING
t)41-0118
4HIMIN
BEST 14ERE
ACCEPTABLE
HERE
NOTE: REMOVE EXISTING SMOKE
DETECTORS, CUT AND PATCH CEILING AS
REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK TAPE AND
TEXTURE AND PAINT TO FILL ALL HOLES
LEFT FROM EXISTING CONDITION. PAINT
TO MATCH SURROUNDING CONDITIONS.
SIDE WALL
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 1 4 "11
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWIL
FEB 0 7 2013
PERMIT CENTER
DETECTOR INSTALLATION DETAIL TYP.
3" = 1 - 0"
S.MSTEMPER
ARCHITECTS
A Professional Limited nobility Company
4000 DELRIDGE WAY SW
SUITE 2C0 • SEATTLE, WA 88106
(206) 624-2777 • FAX 12011) R.24 -2o73
OCTOBER 19,2012
0810.03.2329
0
z0
uJz
KING COUNTY
MPROVEMENTS
›-
wU)2
w
0
z
0
LLI
CO
LLI
AIP NUMBER
3-53-0058-045
DATE
OCTOBER
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
J
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
MISC.
DETAILS
A2.2
0810.03.2329
LFT (E) WALL
LNDERLAYMENT
AWAY LOOSELY'
FROM (E) SHEATHING
AT JAMBS AND HEAD
BUTTERFLY
CORNERS, TY#
NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS REQ'D
(E) SIDING NOT SWOUI4 FOR CLARITY. !REPLACE AND
OR INSTALL NEIU SIDNG AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
12"
LAP SILL MEt18R4NE
FLASHING 2-1/2"
OVER (E) BLDG.
PAF R AT SILL.
EXTEND I" L EYOND
R:O. AT EA, END OF
SILL.
(E) WALL.
LINDERLAYMENT
AT SILL
(E) SHEATHING
CUT SILL
FLASI-ING TO
EIS OF R.O. A5
SHOWY
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FAGS
OF WALL
SHEAT1-LING
I" MIN
I.1!2" TYF'
�4
!BUTTERFLY CORER FLASHING
LIFT (E) BLDG.
PARER AWAY
LOOSELY FROM (E)
SHEATHING At
JAMBS AND HEAD.
(E) SIDING NOT
51-10(1 FOR CLARITY.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
I=NSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANS. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL WOLFS. REMOVE
EXCESS MATERIAL.
DO NOT SEAL' FLANGE
AT WINDOW SILL
(E) WALL
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ't
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMERANE FLASHING
WAS BEEN INSTALLED.
UNDERLAYMENT
AT SILL
REMOVED
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL. REPRESENTATIVE OF DISCREPANCIES
HEE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
EMEND
ANCHORAGE
NAILS DO,N
OVER NAIL
FLANGE, I- EAD
ONLY.
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
EDGE OF (E)
SIDING. SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOW
FOR CLARITY.
LAY (E)WALL
UNDERLAYMENT
BACK DOWN
OVER FLANGE
FLASHING AT
JAMBS
NOTE: REMOVE (E) S11DNVG BACK I=ROM (E) lam. AS RE=
(E) SIDINCa NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW stair* AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
(:I)
HEAD FLASHING PREPARATION
SCALE: NTS
WHERE REQUIRED, TRIM
(E) LU4LL
UNDERLAYMENTAT
HEAD TO PRE ARE
FOR INSTALLATION OF
1 -AD FLASHING AND
WINDOW TRIM
MOLL-al.44 STEPS)
(E) WALL
UNDERLAYMENT
NOTE: REMOVE (E) 5IDFNG SACK FROM (E) R.O. AS REG)'D
(E) SIDING NOT SHOWN FORCLARIT'r. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 SEEN INSTALLED.
-- GUT JAMB FL4SI-INks TO
EDGE CF WINDOW OPENING
AS SHOWN, EXTEND 1-112"
1.112" TPP.
!BEYOND EDGE OF
OPENING AT HEAD, JAMBS,
AND SILL
ADHERE
MEMBRANE
FLASHING TO.
OUTSIDE FACE OF
WALL SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REM)
(E) SIDING NOT SHOIIx4 FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL STT. METAL
HEAD FLASHVsJ
RIDER (E) BLDG
PAPER
TRIMMED EDGE
- INSTALL JAMB FLANGE FLASHING OVER WINDOW'
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
J,,I SCALE NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) Ra AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SONG AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
OF (E) SIDING,
DIAGRAMATICALLY.
(E) SIDING NOT
51-100.N -FOR.
CLARITY.
O
HEAD FLASHING INSTALLATION
ALLOW WV CLEARANCE
8ETt1EEN FLASHING ANY:?
BOT. EDGE OF (E)
SIDING:
SCALE: NTS
(E) WALL
UNDERLAYMENT
/1 MEMBRANE FLASHING AT HEAD
SCALE NTS
CUT 14EAD
FLASHING TO
EDGE OF WINDOW
OPENING AS
51401114. EXTEND
1-1/2" BEYOND
RO. AT PLEAD
AND JAMBS.
ADHERE
PENETRATION!
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TPP. EACH SIDE
OF WALL)
NOTE:'REMOvE (E) SIDING SACK FROM (E) R0. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE ANP
QR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
L
0
0 0
WINDOW FLASHING INSTALLATION
SCALE: NTS
SHEET' METAL HEAD
FLASHING
(E) SIDING
WOOD TRIM INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
BENEATH SIDING
INSTALL WD. TRIM: BLITT
TIGHT TO TRH -PIED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT SEMEN WINDOUJ'
TRIM AND SIDING.
LEAVE I/4" -3/S" GAP
5E11.051 LUNDOW TRIM
ANP WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
1: MEMBRANE FLASHING I5 SPECFFIED IN 01 62 00 AS
"SELF ADHEARINLG MEMBRANE FLASHING" TYPICALLY
REFEREE, TO A5 "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3 DETAILS "5 AND 6" REFER TO MEMPRANLE
INSTALLATION AFTER WINDOW 1-146 BEEN SET 1N PLACE,
5I -wimp, AND ANCHORED.
4: DETAILS "1 AND 8" REFER TO SWEET METAL HEAD
FLASHING.
5: DETAIL'S REFERS TO WOOD TRIM AND CAULK
JOINTS.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 14
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWIL
FEB 0 7 2013
PERMIT CENTER
1)G-01•0
S.MSTEMPER
ARCHITECTS
A . Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200• SEATTLE, WA 98106
(2o,) 624-2777 • FAX Pell) 1124-.297a
OCTOBER 19, 2012
0810.03.2329
ce
0
cec
J
0
cez
LU
0
0
0z
MPROVEMENT
AIP NUMBER
3-53-0058-045
Z
0
N
co
C9
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
J'o
PROJECT MANAGER
ML&TF
DRAWN
LB & CP
WINDOW
FLASH ING
DETAILS
A2.3
031 0.03.2329'
\\
\\\
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL. REPRESENTATIVE OF DISCREPANCIES
HEE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
EMEND
ANCHORAGE
NAILS DO,N
OVER NAIL
FLANGE, I- EAD
ONLY.
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
EDGE OF (E)
SIDING. SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOW
FOR CLARITY.
LAY (E)WALL
UNDERLAYMENT
BACK DOWN
OVER FLANGE
FLASHING AT
JAMBS
NOTE: REMOVE (E) S11DNVG BACK I=ROM (E) lam. AS RE=
(E) SIDINCa NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW stair* AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
(:I)
HEAD FLASHING PREPARATION
SCALE: NTS
WHERE REQUIRED, TRIM
(E) LU4LL
UNDERLAYMENTAT
HEAD TO PRE ARE
FOR INSTALLATION OF
1 -AD FLASHING AND
WINDOW TRIM
MOLL-al.44 STEPS)
(E) WALL
UNDERLAYMENT
NOTE: REMOVE (E) 5IDFNG SACK FROM (E) R.O. AS REG)'D
(E) SIDING NOT SHOWN FORCLARIT'r. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 SEEN INSTALLED.
-- GUT JAMB FL4SI-INks TO
EDGE CF WINDOW OPENING
AS SHOWN, EXTEND 1-112"
1.112" TPP.
!BEYOND EDGE OF
OPENING AT HEAD, JAMBS,
AND SILL
ADHERE
MEMBRANE
FLASHING TO.
OUTSIDE FACE OF
WALL SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REM)
(E) SIDING NOT SHOIIx4 FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL STT. METAL
HEAD FLASHVsJ
RIDER (E) BLDG
PAPER
TRIMMED EDGE
- INSTALL JAMB FLANGE FLASHING OVER WINDOW'
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
J,,I SCALE NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) Ra AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SONG AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
OF (E) SIDING,
DIAGRAMATICALLY.
(E) SIDING NOT
51-100.N -FOR.
CLARITY.
O
HEAD FLASHING INSTALLATION
ALLOW WV CLEARANCE
8ETt1EEN FLASHING ANY:?
BOT. EDGE OF (E)
SIDING:
SCALE: NTS
(E) WALL
UNDERLAYMENT
/1 MEMBRANE FLASHING AT HEAD
SCALE NTS
CUT 14EAD
FLASHING TO
EDGE OF WINDOW
OPENING AS
51401114. EXTEND
1-1/2" BEYOND
RO. AT PLEAD
AND JAMBS.
ADHERE
PENETRATION!
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TPP. EACH SIDE
OF WALL)
NOTE:'REMOvE (E) SIDING SACK FROM (E) R0. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE ANP
QR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
L
0
0 0
WINDOW FLASHING INSTALLATION
SCALE: NTS
SHEET' METAL HEAD
FLASHING
(E) SIDING
WOOD TRIM INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
BENEATH SIDING
INSTALL WD. TRIM: BLITT
TIGHT TO TRH -PIED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT SEMEN WINDOUJ'
TRIM AND SIDING.
LEAVE I/4" -3/S" GAP
5E11.051 LUNDOW TRIM
ANP WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
1: MEMBRANE FLASHING I5 SPECFFIED IN 01 62 00 AS
"SELF ADHEARINLG MEMBRANE FLASHING" TYPICALLY
REFEREE, TO A5 "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3 DETAILS "5 AND 6" REFER TO MEMPRANLE
INSTALLATION AFTER WINDOW 1-146 BEEN SET 1N PLACE,
5I -wimp, AND ANCHORED.
4: DETAILS "1 AND 8" REFER TO SWEET METAL HEAD
FLASHING.
5: DETAIL'S REFERS TO WOOD TRIM AND CAULK
JOINTS.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 14
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWIL
FEB 0 7 2013
PERMIT CENTER
1)G-01•0
S.MSTEMPER
ARCHITECTS
A . Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200• SEATTLE, WA 98106
(2o,) 624-2777 • FAX Pell) 1124-.297a
OCTOBER 19, 2012
0810.03.2329
ce
0
cec
J
0
cez
LU
0
0
0z
MPROVEMENT
AIP NUMBER
3-53-0058-045
Z
0
N
co
C9
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
J'o
PROJECT MANAGER
ML&TF
DRAWN
LB & CP
WINDOW
FLASH ING
DETAILS
A2.3
031 0.03.2329'
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTU
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
READ
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
SRC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
w
WB
W
/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH. EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
SEATTLE RESIDENTIAL CODE
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
MEE
OR XX
0
X/Y
"r///////A
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE. ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY UNE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
AL REPRESENTATIVE. COORDINATE
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL N N
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULA11ON SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS. PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
R
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT,. WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE REFERENCE ONLY. LOCATE
FOR
THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3'-O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
SYMBOL ABBE.
-X
XXX
DN DN
UP I
f +
Imm-m4C
+ r +
-0 0-I-
0 -,
00-
.L.
4 -
UP
VD
RA/EA
RG
SA
SA
RA/EA
SD
EA
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
CD 0 R CD THERMOSTAT
EQUIP IDS EQUIPMENT LOCATION
MOD
NG NG
3
0
•
A
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL/ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
_
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
VOLTS
PHASE
DESCRIPTION
VOLTS
PH
32"Lx12.25"Wx8.5"H
76
120
1
23
26
23
26
N/A
23
26
N/A
BV -1
BLENDING UNIT VENTILATOR
120
1
X
4"
CEILING
X
1, 2, 4
X
1,2
-
SWITCHES (ON, TIMER)
120
1
X
X
X
1
REMARKS:
1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV -1
140
.5" WG
32"Lx12.25"Wx8.5"H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
2
SG -1
140
<.08" WG
8"
8"
CEILING
ALLGRILLE
1, 2, 4
OG -1
90
<.08" WG
7"
7"
WALL
WALL CAP
1, 2. 3,4
RG -1
25
<.08" WG
4"
4"
CEILING
DECO
1, 2, 4
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 5. BASIS OF DESIGN: SHOEMAKER
2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE A. OR APPROVED EQUAL.
3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 6. PROVIDE WITH AN OPPOSED BLADE DAMPER
4. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
WAC
RESIDENCE CODE
FLOOR AREA
(SQ. FT.)
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.2329
970
2
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51-51-1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION
MIN VALUE (NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R-8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING
R-8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R-8
1,3
IN CEMENT SLAB OR IN GROUND
R-5
1.3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULA11ON MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 011101 AND 028200 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED
TO EXTERIOR WINDOW TRIM PAINT.
BV -1 SWITCH HOURS OF OPERATION
SET BV -1 SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
PERMIT CENTER
MECHANICAL VENTILATION CALCULATION
PER SRC M1508.3
QF = QR / (&EGR X F)
QR = (FROM TABLE 1508.2) 4a
acEGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF = 45 / (1 X 1/2) = 90 CFM
D(3 -o4 8
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
EXPIRES: 9/08/2014
S.M.STEMPER
ARCHITECTS
A Psufeerional Llntitted Ltatbillt7 Campng7
4000 DEL IDGE WAY SW
SUITE 200 • RATTLE. WA 08106
(206) 624-2777 Fail (206) 624 -eon
THE GREENBUSCH GROUP, INC
AI OU3 lcM,_ /MO/ VIKO a 2102062001.o199JFFERIN6
1900 rE3r s9EU IsIE 201 SEAM. 9N NM
(206) 376-06ee (206) 376-0641 FAX
AIP NUMBER
3-53-0058-45
TUKWILA WASHINGTON
DATE
09/10/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
00
DRAVVN
JA, DT
LEGENDS,
Sr
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
081003.2329
BEDROOM
2
BATH
20" x 20" EXIST.,
ATTIC ACCESS
PANEL
CLOSET
LOSET
SEE M2.0 TYP ALL
CEILING GRILLES
KITCHEN
BEDROOM
DINING
ROOM
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1'_0"
RETURN AIR
DUCT
HOLD TIGHT TO
STRUCTURE
OUTSIDE AIR
DUCT
MOTOR ACCESS
FILTERS ACCESS
SUPPLY DUCT
COORDINATE ELECTRICAL
AND MAINTENANCE ACCESS
HATCH WITH TECHNICAL
REPRESENTATIVE
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
BV -1 INSTALLATION DETAIL
SCALE: NONE
I 4"O DN
II
20" x 20" EXIST. I
ATTIC ACCESS - 4 ------ I 1
PANEL
LL _
ATTIC MECHANICAL PLAN
SHEETMETAL
TRANSITION TO WALL
CAP NECK SIZE
DUCT PER PLAN
CAULK
2X BLOCKING
2X BLOCKING
FOAM BACKER
ROD
WALL CAP
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS.
�WALL CAP DETAIL
SCALE: NONE
r NORTH
DN
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
2X BLOCKING
SLEEVE AND
ESCUTCHEON
GRILLE
DRAWING NOTES:
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION
IS AT MINIMUM 10 FEET AWAY OR 3 FEET
BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SRC M1508.6.6.
2. FILTERS: AFTER EQUIPMENT AND SYSTEM
CHECK-OUT WORK HAS BEEN COMPLETED
AND PRIOR TO COMMENCEMENT OF TAB
WORK, PERFORM THE FOLLOWING:
A) REPLACE AIR FILTERS IN THE
FURNACE AND/OR BLENDING AIR
UNIT SYSTEM(S) WITH NEW FILTERS.
FLAG NOTES:
13V-1 AND DUCTWORK ROUTED IN ATTIC.
COORDINATE ELECTRICAL AND MAINTENANCE
ACCESS HATCH WITH TECHNICAL REPRESENTATIVE.
ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER
SWITCH BY TECHNICAL SPECIFICATIONS SECTION
260010. AFFIX A LABEL TO THE CONTROLLER THAT
READS "WHOLE HOUSE VENTILATION (SEE
OPERATING INSTRUCTIONS)" PER SRC M1508.6.4.
COORDINATE FINAL SWITCH LOCATION WITH
HOMEOWNER.
TRANSITION DUCT TO AIR TERMINAL NECK SIZE
IMMEDIATELY BEFORE MAKING FINAL GRILLE OR
DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS REQUIRED TO
INSTALL OUTSIDE AIR INLET, REFER TO
ARCHITECTURAL DRAWINGS AND TECHNICAL
SPECIFICATIONS.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE
MINIMUM DUCT INSULATION THICKNESS SCHEDULE
ON M1.0.
COORDINATE SOFFIT
WITH TECHNICAL
REPRESENTATIVE
FIELD FABRICATE
PLENUM BEHIND
CEILING GRILLE
FOAM BACKER ROD
CAULK
2X BLOCKING
FLOOR OR
CEILING JOIST
CEILING
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
CEILING GRILLE DETAIL
SCALE: NONE
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
PERMIT CENTER
I EXPIRES: 9/08/2014
S.M. STEMPER
ARCHITECTS
A Profsaaional Ilsnitad Lialditj Companx
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE,. WA 98106
(206) —8777 . FAX (806) 624--6678
THE GREENBUSCH GROUP, INC
Aoou woo *MECINICAL oaNEEnw)
110) VEX I ON EMT ME 101 SFAUE, WA MI6
too 370-0069 (206) 376-0e41 FAX
0810.032329
MPROVEMENTS
0
co
RESIDENTIAL AIRCR
AEP NUMBER
3-53-0058-45
ILA WASHINGTON
DATE
09/10/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.2329
`/ •
4.2,C)
LOCATION:
SES T
AA4P with MAIN
EXISTING LOAD
EXISTING LOAD
EXSTI NG LOAD
EXISTING LOAD µµ
EXISTING`LOAD
XI s -n NG LOAD
EXISTING LOAD
....
EXISTI SIG LOAD
E>3STIN3 LOAD
EXISTING LO
EXISTINGLOAD
EXISTING LOAD
EXISTING LOAD
s'n NG L.DA,D
Eis-nrsq. LOAD.. .. ,
EN STING LOAD
EXISTING LOAD.H.
EXISTING LOAD
EN STING LOAD
EXISTING LOAD
EXISTING LoAp
EXISTING LOAD
EXISTING LGA
EXISTING LOAD
BLENDING UNIT
SPACE .:....
SPACE
SPACE :....... .....
SPACE
SPACE:
SPACE
SPACE
SPACE ....
SPACE.
SPACE
[ ISOLAATED GROUND SUS
RAINI1GHT NENIA 3R ENCLOSURE
REMARKS:
0 FEED THRU LUGS 0
DOUBLE LUGS
NORTH
ELEcTRIcAL
LEGEND
SYMOL
IDEWRIPTIM
SYMBOL
- ION
mai
LIGHTING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPEgFlC REQUIREMENTS.
0
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT NE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
t2 AWIG, 1/210. mu INT OR RIGID STEEL 1 INDICATES EQUIP GNI).,
1 INDICATES ISOLATED GROUND.
MAST, WEATHERHEAD
DAMPER CONNECTION
D
Di
NON-FUSED' DISCONNECT S ITCH
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
-
BRANCH CIRCUIT HOME RUN
ELECTRICAL METER
`-i?
i
SMOKE DETECTOR
TIMER OPERATED SWITCH
—°-
-- - -
AERIAL SERVICE CONDUCTORS, COORDINATE WITH umurt
CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT
- +.
THERMCSTAT
LNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DEIECTOR
ELECTRICAL -PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE 'INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER`
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE'
SHEET ROCK, TAPE AND RE AND PAINT TO F1LL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT, COORDINATE WORK WITH' MECHANICAL DRAWINGS.
0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE.
HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY
CEILING OR WALL PENETRATION WORK.
ATTC.
SEE FLOOR PLANS FOR
LOCATIONS OF BLENDING UNITS
AND TIMER SWITCHES
MP
2#12NMB + G,
OR EQUAL
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
?ERIUMIT CENTER
Q 13-0 �t 8
ELECTRICAL ONE -LINE
NOT TO SCALE
SEPARATE
PERMIT AND
AP P ROVAL
REOJRED
S.MSTEMPER
ARCHITECTS
9 Professional Limited liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(BO6) 524-2777 • PAX X266) 624-2973
111 INGINEEM UM
w SMITE or rrr Sri M
TA
N
::1NOM r.
0810.03.2329
ce
0
J
0
Z
w
Z
Z
0
0
Z
MPROVEMENTS
AIP NUMBER
5-53-0058-045
DATE
SEPT 17, 2012
ISSUED
95%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
D RAVUN
BCR
FLOOR
PLANS
NOTES
E1 .0
081 0.03.2329