Loading...
HomeMy WebLinkAboutPermit D13-050 - NGUYEN RESIDENCE - REMODELNGUYEN RESIDENCE 12055 44 AV S D13-050 City of Oukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 3347400420 Address: 12055 44 AV S TUKW Suite No: Project Name: NGUYEN RESIDENCE DEVELOPMENT PERMIT Permit Number: D13-050 Issue Date: 08/07/2013 Permit Expires On: 02/03/2014 Owner: Name: NGUYEN THANH D Address: 12055 44TH AVE S , SEATTLE WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: S K M CONSTRUCTION INC Address: 14415 SE 143 PL , RENTON, WA 98059 Contractor License No: SKMCOI*052L3 Lender: Name: Address: Phone: 206-296-7437 Phone: 425 235-5569 Expiration Date: 12/30/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $28,475.00 Fees Collected: $1,067.51 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT **continued on next page** doc: IBC -7/10 D13-050 Printed: 08-07-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Storm Drainage: Street Use: Profit: N Water Main Extension: Private: Water Meter: N Permit Center Authorized Signature: 1 Date: Public: Non -Profit: N Public: 1 hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie whether specified herein or not. The granting of this permit does not prem e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit Signature: si.Ve MQ Th Date: .3(--1 I F3 Print Name: ael( (a i This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D13-050 Printed: 08-07-2013 this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. doc: IBC -7/10 D13-050 Printed: 08-07-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cltukwila.wa.us Building Permit No. b `3- 6; Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 3347400420 Site Address: 12055 44th Ave S Tenant Name: Thanh Nguyen Suite Number: Property Owners Name: Thanh Nguyen Mailing Address: 12055 44th Ave S Floor: New Tenant: 0 Yes ..No Tukwila WA 98178 City State Zip CONTACT PERSON who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296-7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker@kingcounty.gov City State Fax Number: (206) 269-7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Jesse Holgate or Timothy Fenlason E -Mail Address: Jesse@smstemper.com/tfenlason@jonespayne.cce City State Day Telephone: (206) 624-2777 Fax Number: (206) 624-2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applications\Fotms-Applications On Lme\2009 Applicanons\1.2009 - Permit Apphcauon.doc Revised: 1-2009 bh State Zip Page 1 of6 • • BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 28,475 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? 0 Yes Z.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On L,ne\2009 Applications \1-2009 - Permit Appltcanon.doe Revised: 1-2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 15` Floor 955 2"d Floor 275 3'd Floor Floors thru Basement 742 Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On L,ne\2009 Applications \1-2009 - Permit Appltcanon.doe Revised: 1-2009 bh Page 2 of 6 PERMIT APPLICATION NOTES = Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN Signature: ED AGENT: Date: /3 Print Name: Timothy J. Fenlason, SM Stemper Architects, PLLCDay Telephone: (206) 624-2777 . Seattle Mailing Address: 4000 Delridge Way SW, Suite 200 WA 98106 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:\Applications\Forms-Applications On Line\2009 Applications\I-2009 - Permit Application.doe Revised: 1-2009 bh Page 6 of 6 City oaTukwilar Departmen of Community Development 6300 Southcenter Boulevard, Suite 4100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http:/fvww.ci.tukwila.wa.us SET RECEIPT Copy Reprinted on 02-19-2013 at 09:09:21 02/19/2013 RECEIPT NO: R13-00837 Initials: WER Payment Date: 02/19/2013 User ID: 1655 Total Payment: 5,833.28 Payee: PAMELA K KUEHL (BY PHONE) SET ID: 020713 SET NAME: KING COUNTY SOUND ABATEMENT SET TRANSACTIONS: Set Member Amount D13-045 811.18 D13-046 842.70 D13-047 716.64 D13-048 748.15 D13-049 622.10 D13-050 1,067.51 M13-038 167.70 M13-039 167.70 M13-040 167.70 M13-041 167.70 M13-042 167.70 M13-043 186.50 TOTAL: -4 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 5,833.28 TOTAL: 5,833.28 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES 000.322.100 2,897.75 MECHANICAL - RES 000.322.102.00.0 1,025.00 PLAN CHECK - RES 000.345.830 1,883.53 STATE BUILDING SURCHARGE 640.237.114 2-7-70'0 TOTAL: 5,833.28 INSPECTION RECORD Retain a copy with permit 013 - Os 0 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 (206) 431-3670 Project: JQ &u , e' iQeS Typef_Inspection: .., ruA b� . I4•%I6 Address: '71, A '. Date Called: Special Instructions: = Date Wanted:J (ap.m t- -� 3 p.m Requester: _ PhoneNo: COSI - 222-7 Approved per applicable codes. t_. J Corrections required prior to approval. COMMENTS: P,M :7 to Inspector: Date _ L3 n REINSPECTION F RE. - '. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 07-01-2013 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit Application No. D13-050 NGUYEN RESIDENCE 12055 44 AV S TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 02/07/2013, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 08/06/2013. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. DI3-050 6300 Southcenter Boulevard, Suite 11100 • Tukwila. Washington 98188 • Phone 206-431-3670 • Fay 206-431-3665 talahil" ID COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-050 PROJECT NAME: NGUYEN RESIDENCE SITE ADDRESS: 12055 44 AV S X Original Plan Submittal Response to Incomplete Letter # DATE: 02-07-13 Response to Correction Letter # Revision # After Permit Issued. DEPARTMENTS: ding Division Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator IP DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 02-12-13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route slY1, Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: DUE DATE: 03-12-13 Not Approved (attach comments) ❑ REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Prinriendly Page • General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name S K M CONSTRUCTION INC UBI No. • 601577401 Phone 4252355569 Status Active Address 14415 Se 143Rd PI License No. SKMC0r052L3 Suite/Apt. License Type Construction Contractor City Renton Effective Date 6/23/1995 State WA Expiration Date 12/30/2013 Zip 98059 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SKMC0,•093L6 5 K M CONSTRUCTION Construction Contractor General Unused 6/26/1991 6/17/1995 Archived SKMINI"976QL S K M INDUSTRIES INC Construction Contractor General Unused 11/13/2003 12/6/2009 Expired Business Owner Information Name Role Effective Date Expiration Date MORRISON, SHEILA K President 06/23/1995 Bond Amount MARKET SANDERS Agent 06%23/1995 06/25/2001 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 FIRST NAIL INS CO OF AMERICA 6695979 06/17/2010 Until Cancelled $12,000.0004/26/2010 4 DEVELOPERS SURETY Et INDEM CO 188889C 12/30/2001 Until Cancelled 08/01/2010 $12,000.00 12/05/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 16 James River Ins 000495931 08/21/2012 08/21/2013 $1,000,000.0008/20/2012 15 James River Ins 00049593 08/21/2011 08/21/2012 $1,000,000.0008/18/2011 14 COLONY INS CO EPK300402 08/21/2010 08/21/2011 $1,000,000.0008/20/2010 13 CENTURY SURETY CO CCP616634 08/21/2009 08/21/2010 $1,000,000.00 01/20/2010 12 AMERICAN STATES INS CO 01CH6810051 01/25/2009 01/25/2010 $1,000,000.00 01/23/2009 11 AMERICAN STATES INS CO 01CH6810051 12/30/2008 01/25/2009 $1,000,000.00 12/23/2008 10 AMERICAN STATES INS CO 01CH6810051 12/30/2007 12/30/2008 $1,000,000.00 12/07/2007 9 AMERICAN STATES INS CO 01CD87273820 12/30/2006 12/30/2007 $1,000,000.00 12/19/2006 httns://fortress.wa. aov/1ni/bbip/Print. aspx 08/07/2013 KING COUNTY INTERNATIONA L AIRPORT RESIDENTIAL AIRCRAFT NOISE REM EDY IMPROVEMENTS PROGRAM - 000784012 BID PACKAGE M-37 3-53-0058-045 SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PRovIDI= MECCNIdDNCs BUT NOT TED vENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND SPEIFiCAt1QN5 CL LIMITED 70 APPLICABLE YES NO 1. SELECTIVE REPLACEMENT OF EXISTING WNDOWS WITH NEW VINYL -FRAMED ACOUSTICAL WINDOWS. X 2. CUT DOWN QF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X a: INSTALLATION OF PET DOORS X 9. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 10. INSTALLATION OF CHIMNEY CAP. X 11. REGULATED MATERIALS ABATEMENT. X 12. ATTIC VENT BAFFLES. X 13. INSTALLATION OF ATTIC INSULAT1ON. X 14. NSTALLATION OF MECHANICAL VENTILATION EQUiPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECI-IANICAL VENTILATION AND ARCI4ITECTIJRAL MODIFICATIONS. X 18. NSTALLATION OF SMOKE DETECTORS. X 19. NEW ELECTRICAL PANEL / SERVICE. X 20. KNOB AND TUBE WiRING X FILE COPY Permit fro.'p td 050 r-"!2;11 approval is subject to errors and omissions. t,,_ .. of c.;:,?r,truction documents does not author ze t1; ^: L ;f adopted code or ordinance. Receipt o► i r�z� � ; F oCopy and conditions isadcnow : By Data. I Z 17Th City Of lbkwila BUILDING DIVISION RE`d'I3IONS r "w ._es/M�-^ f-115,711%.1 mom(ae to the, t . scope prior rIpp-ro)1 of C!iilding Division n. t:;'1 r qu!re t n^w pan submittal .��review�s. l (Zs: a 9 Re 1V,, zsi� rn n►:;iIT FOR. ar eci anicaI tecrical Iumbing E s Piping Tuk?„'il8 rvVISION SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Seattle, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, International Mechanical Code 3341400420 ZONIt45: 5F1200 OCCUPANCY: (No Change) SNGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) V 6 NON SPRNKLERED' REVIEWED FOR CODE COMPLIANCE APPROVED FEB 14 ?nil /4-3- 14K City of Tukwila BUILDING DIVISION LEGAL DESCRIPTION: LOT(5)18 AND 19, 6LOCK 2, C D HILLMAN'S MEADOW GARDENS ADDITION TO TI4E CITY OF SEATTLE, DIVISION Na I, ACCORDING TO THE PLAT THEREOF RECORDED IN vOLUME 12 OF PLATS, PAGE(6) 64, RECORDS OF KING COUNTY, WASHINGTON. SITUATED IN THE COUNTY OF KING, STATE OF WASHINGTON, DRAW' NG INDEX T00 TiTLE SHEET, PROJECT lhFO. Allo FLOOR PLANS 4 NOTES A2.0 WINDOW TYPES, SCHEDULE 4 DETAILS A2.I DOOR TYPES, SCHEDULE 4 DETAILS A22 MISCELLANEOUS DETAILS 42.3 WINDOW FLASHING DETAILS i11.0 LEGENDS, SCHEDULES, ABBREV, GENERAL NOTES 4 DWG INDEX 112.0 MECHANICAL PLANS AND DETAILS 112.1 MECHANICAL PLANS AND DETAILS Ei.0 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY iNTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Pii 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E-mail: Sharyn.Parkerekingcounty ov ARCHITECT: Stamper Architects PLL.C. 4000 Delrldge Way SW, Suite 200 Seattle, WA 98106 Fh: 206. 624. 2111 Fax:: 206.624.2913 Contact: Jerry Osborn, Melody Leung E -ma 11: Jerryesmstemper.com melodyesmatemper com ACOUSTICAL INEER: 55A Acouatica 222 Etruria Street, Suite 100 Seattle WA 98109 Ph 206.83%.0819. Fax: 206.839.0824 Contact: Mohamed Aft Ailaoua E-mail: mohamedissaacoustics.com MECHANICAL ENGINEER: The Greenbuech Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph: 206. 318. 0569 Fax: 206. 318. 0641 Contact: Dylan Tuner E-mail: Dylantegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253. 412. 3463 Contact: Brent Rollins E-mail: bcretreswest.co n REGULATED MATERIALS: PB6 Engineering and Environmental 2511 Eastlake Ave. E, Suite 10.0 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206.162. 4180 Contact: Tim Ogden E-mail: tin ogdenepbaenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. nee Boston, MA 02114 Contact: Tim Fenlaeon, Cynthia Maeda E-mail: trenlason.Jonespayne.com CMaedaeJoneepayne.com STRUCTURAL ENGINEER Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 F11 206.622.4580 Fax: 206.622.0422 Contact: Ron Martlnaon E-mail: ronmepam-engineerscom RECEIVED CITY OF TUKWILA FEB 0 7 2013 PERMIT CENTER VICINITY MAP (NTS) S.M.STEMPER ARCHITECTS A Professional Limited Liability .Company 4000 DE.LRIDGE WAY SW SUITE 206 •SEATTLE, WA 98106 (206) 624-2777 FAX (206) 624-2973 OCTOBER 19, 2012 0810.03.2326 1 O J 0 p z w 1- Z z 0 0 0 Z AIP NUMBER MPROVEMENTS >- 0 w w w 0 z U ceD 11' 3-53-0058-045 z 0 1- 0 z H DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP PROJECT INFORMATION, DRAWING INDEX, DIRECTORY T0.0 0810 03.2326 STUDY STORAGE BEDROOM 2 E3AT4-1 FAMILY ROOM FUR FAMILY ROOM P EIDROOM LIYINCx ROOM KITCHEN y' SPECIAL NOTES: 1, ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. TI -E CONTRACTOR leEMOvNG ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO 14AvE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE coWTRACTOR SHALL IDENTIFY, QUANTITY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01 11 01 AND 02 82 00 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT 15 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 11 01 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. 3. THIS RESIDENCE HAS EXISTING WIDE TRIM. NEW TRIM TO MATCH EXISTING. REFERENCE 6/A22 FOR PHOTO. 4. REFERENCE 1/422 FOR SMOKE/ CARBON MONOXIDE DETECTOR INSTALLATION DETAIL. LOWER FLOOR PLAN 1/4"=1'-Q" fr- PRIOR TO COMMENCING WITH DEMOLITION A "pre -demo inspection" is required. Contractors shall provide documentation that an "asbestos survey" has been completed. If needed, abatement procedures per "Puget Sound Clean Air Agency" shall be completed and documentation of compliance shall be provided at time of final inspection. GENERAL NOTES 1. CONTRACTOIR TO PROTECT GONERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. CONTE=NTS WALL HANGINGS 8 AND FIXTURES A6 REQUIRED TO EXECUTE THE WORK OF 2. CONTRACTOR TO TEMPORARILY RE=MOVE. F.IRNIYlIF�, , THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE CO1PLETIO4 OF WORK DAILY. 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE; AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. Fl0h1I=ONl1hIER5 WILL HAVE COMPLE=TE ACCESS TO THERESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS. T 'AL ALL NOT BE REMOVED UNTIL REPLAGI=METIT DOOR OR WINDOW 15 ON SITE_ REMOV S. DOORS OR WINDC711S SCHEDULED TO BE REPLACED SH AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR 014 THE SAME DAY BETWEEN &_00 ,AM AND 5:00 PM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS ARE EXI3TNG IUINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT REGI -NIDAL REFRESE=NTATIvE IF DETERIORATION 16 UNCOVERED. 'I. ADP SOLID WOOD BLOCKING AT WNDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION F'ROGEDURE ON WINDOW FLASHINGS DE TAI 5 ET FOR WINDOW REPLACEMENT. L 5H E COVERINGS EXI5TRNG WINROW BE REINSTALLED MUST ON THE SAME DAY A5 COMPLETION OF WINDOW INSTALL. IF WINDOW ARE NOT AVAILABLE, OR INSTALLATION AND/OR FNISHE5 ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. 5EE WNDOW' TYPE SCHEDULE. 11. ALL WORK AREAS SHALL 13E BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MEC14. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SI-ELVING AS REQ'D AND RE -CONSTRUCT 51-ELVING, IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTJJGT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY A5 POSSIBLE TO EXIST G. RECONSTRUCT 51-1ELvING 60 A5 NOT TO NTERFERE WITH TI -IE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY' ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY T14E WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS T1-IR000sHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS, AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE NSTALLATION OF TIMED. PATCH AND FINISH WALL AFTER WORK. REFER TO ELECTRICAL FOR TIMER LOCATION IS NSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AL0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL S14EET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED 51'10KE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. a CONTRACTOR 13 TO vER1FY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR 114' FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES COORDINATE WITH MECHANICAL. 20. MAXIMUM POIIJER CXITAr. E IS EICMIT HMO. PG(IER MUST 19E PROVIDED AT RESIDENCE ESEFORE &CO AM 4 AFTER 6W P 't., A. EAST ELEVATION PLAN KEYNOTES 0 DEMOLISH (E) WNDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. S . INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND DEMOLISH EX{STING DOOE�5), FRAMECASINCx, TRIM AND THRESHOLD. 2 STORM DOOR REF. DOOR SCHEDULE... (7\ DEMOLISH EXISTING'DOOR(3), FRAME, CAGING, TRIM AND THRESHOLD_ INSTALL NEW NTERIOR DOOR, FRAME, AND CASING. REF. DOOR ‘,.::1 ScI-IEDULE. •ILLE. REF. 1A2.2'FOR DETAIL. COORDINATE 111111-1 0 EXTERIOR' WALL ASSEMBLY AS REQUIRE!): FRESH AIR INTAKE Csl2 MECHANICAL DOCUMENTS M TS. RENETRATION SHALL I5E CUT FULL SIZE OF DUCT AREA. REF. Maw. � , GOORONATE:IUALL GRILL WITH MECHANICAL DC)CU EN WALL INSTALLATION DETAIL, -OBL=DfNG UNIT LOCATED ADJACENT TO (E).NATGH INSTALLED INATTIG, RQ, MEG. DQCJM=1T5 FOR N17, REF. ELECT. DOCL E4 TS DETAIL__ Fo R SPEED GONTROLAhDR 15COVhEGT. . 21422 FOR IL BLENDING UNIT LOCATED AND INSTALLED 114 SOFFIT WITH 16"X16" ACCESS I -LATCH, RIF. MECI.4. DOCUMENTS FOR UNIT, REF. ELECT. 1 DOCUMENTS FOR SPEED CONTROL AND DISCONNECT. ONSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE WITH MECHANICAL AND ELECTRICAL C) REMOVE AND RE -INSTALL EXISTING LIGHT FIXTURE. CINSTALL NEW 4X6 I4EADER LOWER (E) WINDOW HEAD HEIGHT 8" TO ALLOW NEW HEADER NSTALLATION. REF. 5/423 FOR DETAIL. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PAW N OR SLOCK ACCE=SS TO ROI EO4NER DRIVEWAY. (E) Arr IC SPACE !CLOSE T"LOSE" _# (E) ATT1C SPACE BEDROOM 3 11 0 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 14 "fro City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 0 7 2013 PERMIT CENTER B. SOUTH ELEVATION LEGEND »»»»,»,`-- ACOUSTICAL WINDOil REFER TO WINDOW: SCHEDULE ACOUSTICAL DOOR/ STOW ORM DOOR REFER TO DOOR 61-1EDULE C. WEST ELEVATION bst3,osio SECONDARY BRIDING GLASS STOW DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL ISH AIR INTAKE GRILLE. REFER TQ MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION P1 -10t0 VIEW 111111 111111 GABLE END VENT BAFFLE ROOF VENT E3AFFLE EXHAUST !SAME KITCHEN IEATNER'TEXTURED CI=ILNG OVER AT A MN. OF, 24" FROM EDS OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC A C ESS PANEL CE CEILNG DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. REF. MECI-1. 1 ELECT. REF. GENERAL NOTE rt ATTIC INSULATION ATTIC INSULATION DAM INSTALL BATTERY OPERATED SMOKE DETECTORS INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER SOFFIT FOR MECHANICAL DUCTING S.M.STEMPER ARCHITECTS Prafe2sionat Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, Wk 98106 (20.0) 624-2777 • FAX (208) 624-2973 OCTOBER 19., 2012 0 0 0810,03.2326 MPROVEMENTS >- w 2 w OC w 0 z LL 0 C V w AIP NUMBER 3-53-0Q58-045 DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT J'O PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES A1 .0 0810.03.2326 WINDOW TYPES 1. DOUBLE-IUN* 2. HORIZONTAL XX SLIDER 3. CASEMENT WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS DETAIL SET A LIVING ROOM 1 31-1" c 4'-4" STAIN/STAIN REMOVE AND REINSTALL (E) SHUTTERS 1/42.0 1/.42.0 B BEDROOM I 3 21-6" x 41-4" 5TA1N/STAIN REMOVE AND REINSTALL (E) SHUTTERS C BEDROOM I 3 21-6" x 4-4" STAIN/STAIN REMOVE AND RE NNTALL (E SI-kiTTERS 1142. D BEDROOM'2 3 21-6" x 41-4" STAIN/STAIN 1/42 E BEDROOM 2 3 21-6' x 4 -4" STAIN/STAIN 1/42.0 F STAIRWAY 2 4'-10" x 41-10" STAIN/STAIN NEW 4XB IaEAD1=R REQ'D. LOWER (E) HEAD 1.41 8". !REF. 5/A22, SAFETY GLAZING REQUIRED 3/4.2. G DINft' ROOM 2 4'-10" x 3`-3" STAIN/STAN REMOVE AND REINSTALL (E) SKITTERS 1/4\2.0 14 DINING ROOM 2 4'-10" x 3'-3" STAN/STAIN REMOVE AND REINSTALL (E) SHUTTERS 1/42.0 I KITCHEN 1 2'-4" x 3'-0" STAIN/STAIN REMOVE AND REINSTALL (E) SHUTTERS 1/42.0 J FAMILY ROOM 2 21-4" x 11-1" STAIN/STAIN SAFETY GLAZING REQUITED 21,42 K FAMILY ROOM 2 21.9" x I'-10" STAN/STAN SAFETY'GLAZNG REQUIRED 2/42.0 L FAMILY ROOM 2 2'-9" x 11-10" STAIN/STAIN SAFETY GLAZING REQUIRED 2/A2.0 M STUDY" 3 2'-9"'x 11.10" STAIN/STAIN SAFETY GLAZING REQUIRED 2/42 N BEDROOM 3 3 2'-4° x 11-1" STAIN/STAIN IEMOvE AND REINSTALL (E) SHUTTERS 1/42.0 1/42 ) O BEDROOM 4 3 21-4" x 11-V" STAIN/STAIN TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TD BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2 FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3 HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET. SLOPE I OSUR END GL HEMMED EDGE HEAD FLASHING DETAIL TYP. 3" = ,1' - 0"... REVIEWED FOR CODE COMPLIANCE APPROVED FEB 14 (E) SACKER BOARD (E) ALUMINUM SIDING CAR BILLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADI -ENING FLASHING AGAINST SHEATHING. LAP OVER METAL FLA5I4ING AND EXTEND SELF ADS FLASHING 4" UP WALL FROM TOP 0 FLASI-ING. LAP' (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERNG'FLA4HIN& REMOVE (E) ALUM. SIDING: AS REQ'D FOR INSTALLATION OF WINDOW 4 FLASHING. SALVAGE AND RE -INSTALL (E) ALUMINUM SID! PRE -PRIMED, GALV SHEET METAL (E) EXTERIOR SHEATHING (E) GWS (E) WALL UNDERL..4TENT SELF ADHERING: ME 1 IR4NE TOUCH UP PAINT, A8 REQ'D CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM FLASHING UNDER SELF -ADHERING 1MEM8RANE. COLOR TO BE SELECTED IN THE FIELD TR1`1- MATC44 (E) TRIM. PRIM 'ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY (E) BACKER BOARD SOLID P.T.13LOCKING FRE -PRIMED GALV..JAMB FLASHING LAP INTO SILL PAN FLASHING. EMBED LAP IN SEALANT. FIELD PAINT FLA5I4f - COLOR TO 13E SELECTED IN THE FIELD SILL PAN FLASHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY SEF -ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY JAMA FLASI.IING SEALANT 4 BACKER ROD WINDOW HEAD SHIM AS NECESSARY FILL GAP IW BATT INSULATION SEALANT 4 SACKER ROD CAREFIIL.LT REMOVE (E) ALUMINUM SIDING. CUT BACK (1=) BACKER BOARD AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. INSTALL SOLID P.T. BLOCKING TO PROVIDE NULLING FOR 13ACKEIR BOARD. 'RE- INSTALL REPLACEMENT SACKER BOARD 1 (E) ALLJMINUI"i SIDING' (E) GWS (E) EXTERIOR SHEATHING: (E) BUILDING: PAPER TOUCH UP PAINT, AS REQ'D CONTINUOUS SEALANT, TTP. SOLID wax) TRIM WD. JAMB LINING. FN1514 TO MATCH (E) BACKER ROD SEALANT WINDOW JAMB 11 3/4" TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED SILL ALUM. UNDER SILL TRIM NEW BLOCKIN x CAREFULLY REMOVE TOP COURSES OF (E) SIDING AND BAGGER 130ARD FOR INSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING: TO MATC44 (E) (E) SACKER' BOARD (E) ALUMINUM SIDING WINDOW SILL 61-411'1 AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 SACKER IDD 3/4" WOOD SILL SOLID WOOD TRIM CONTINUOUS' SEALANT, TYR TOUCH UP PAINT, A5 REQ'D SELF -ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT 4" LAP SELF ADHERING MEMBRANE AT JAMBS OVER TOP OF SILL MEMBRANE EXTENSIONS (E) GLIB ALUMINUM SIDING -WINDOW DETAIL SET 3" = 1' - 0" l UNDETERMINED (E) SIDING SUBSTRATE, (E) BAGI(ER BOARD CAREFULLY LIFT (E) WALL UNDERLAYME AND INSTALL TOP EDGE OF SELF ADI-4ERING FLASHNt AGAINST SI4EATI 4NG. LAP OVER METAL FLASI-LING AND EXTEND SELF ADHERNG FLASHING: 4" UP WALL FROM TOP CF FLASHING. LAP (E) WALL UNDERLAYI"IENT OVER Tom'' OF SELF ADI4ERING FLASHING. REMOVE (E) ALUMINUM BIDING AS REQ'D FOR INSTALLATION OF WINDOW t FLi4Si 4INA REPLACE/ RE -INSTALL SIDING 4 ACCESSORIES TO MATCH (E). J CHANNEL TRIM PRE -PRIMED, GALV SHEET METAL FLASI4ING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED 114 THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDE AND PAINT TO MATCH (E) TRIM. COLOR' TO 8E FIELD DETER`tINEP ACOUSTICAL WINDOW ASSEMBLY (E) SACKER BOARD WINDOW HEAD UNDETERMINED (E) SIDING SUBSTRATE J CHANNEL TRIM (E) EXTERIOR SHEATHING: (E) WALL UNDERLAYMENT SELF -ADHERING MEMBRANE SHIM AS NECESSARY FILL GAP W/'EATT 1N5.1LATION SOLID WOOD TRIM WD. JAMS ;LINING: SEALANT 4 BACKER ROI'? CAREFULLY REMO (E) ALUMINUM SIDING. GUT BACK (E) BACKER BOARD AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. INSTALL SOLID P.T. BLOCKING TO PROVIDE NAILING FOR SACKER BOARD. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) VINYL SIDING: TOUCH UP PAINT, AS REQ'D CONTINUOUS SEALANT, TYP. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO 8E FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD AND SEALANT WINDOW JAMB SOLID WOOD TRIM WD JAMB LINRNG SEALANT SHIM AS NECI=SSARY FILL GAP UJ/ BATT INSULATION SEALANT 41BACKER ROD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO SE FIELD DETERMINED J CHANNEL TRIM SELF -ADHERING MEMBRANE UNDETERMINED VINYL &ID ING SUBSTRATE CAREFULLY REMOVE TOP C0UP E5''OF (E) VIN'rL SIDING MD SACKER`13OARD FOR INSTALLATION OF WINDOW ASSEMBLI" 4 TRIM. REPLACE/ RE -INSTALL SIDING TO MATCH (E) (E) SACKER BOARD (E) SIDING f 3/4" WOOD SILL SOLID WOOD TRIM CONTINUOUS SEALANT, TOUCH UP PAINT, AS REQ'D 2"X8" PRESSURE TREATED WOOD ii (E) CONCIETE WALL WINDOW SILL ALUMINUM SIDING WINDOW DETAIL SET 311=1'-0" (E) EXTERIOR SHEATHING City of Tukwila BUILDING DIVISIOt. SELF ADHERING MEMBRANE (E) WALL UNDERLAYMENT PLASTER WALL TOUCH UP PAINT, AS REQ'P CONTINUOUS SEALANT, TYP. J -METAL JOINT COMPOUND W/ FLAT FINISH. (DEMOLISHED PLASTER AREA NOT TO> EXCEED NEW TRIM AREA) SOLID IUOOP TRIM WP. JAMB LINING SEALANT PRE -FIRMED, GALY MEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COL0R'To SE SELECTED' IN THE FIELD FRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER' ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY (E) BACKER BOAT SOLtp PT.13LOCKING WINDOW HEAD SHIM AS NECESSARY FILL GAP Ill/ BATT INSULATION CAREFULLY REMOVE (E) ALUMINUM SIDLING. GUT BACK (E) BACKER BOARD' AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. INSTALL SOLID FT. BLOCKING TO PROVIDE NAILNCs FOR SACKER BOARD. RE- INSTALL REPLACEMENT BACKER ABOARD 1 (E) ALUMINUM SIDINiC PRE -RIMED GALV JAMB FLASHING LAP —\\ INTO SILL PM FLASHING. EMBED LAP IN SEALANT. FIELD PAINT' FLASHING - COLOR TO ISE SELECTED N THE FIELD SILL PAN FLASHING BACKER ROD a .SEALANT ACOUSTICAL WINDOW ASSEMBLY SELF -ADHERING MEMBRANE JAMB FLASHING (E) EXTERIOR Sl. EATI4IN G (E)'BUILDING PAPER TOUC14 UP PAINT, AS I4EQ10 CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM ULJ JAMB LINING. FINISH TO MATCH (E) BAGGER ROD SEALANT WINDOW JAMB TRIM- MATCH (E) TRIM. PRIME ALL SIPES AND PAINT TO MATCH (E) TRIM. COLOR TO 131r FIELD DETERMINED SILL ALUM. UNDER SILL TRIM NELU BLOCKING CAREFULLY REMOVE TOP COURSES OF (E) SIDING AND !BACKER BOARD FOR INSTALLATION OF WINDOW ASSEMBLY TRIM. REPLACE UJ/ NEW SIDING TO MATCH (E) (E) BACKER BOARD (E) ALUMINUM SIDING RECEIVED CITY OF TUKWILA. FEB 0 7 2013 PERMIT CENTEP 814111 AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD 3/4" WOOD SILL SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. TOUCH UP PAINT, AS IEQ'D SELF ADHERING MEMBRANE LAP OVER (E) WALL IkIDERLAYMENT 4" LAP SELF API-IERINC MEMBRANE AT JAMBS OVER TOP Cr SILL MEMBRANE EXTENSIONS WINDOW SILL t) u3 -0s0 ALUMINUM SIDING - WINDOW DETAIL SET 311=1'-0" S.MSTEMPER ARCHITECTS A Pmiessiomal Limited liability Cempany 4000 DELRIDGE WAY SW SUITE 2C{I • SEATTLE, WA 98106 FAX (206] 82 73 4-29 (208} 624-2777 • OCTOBER -19, 201 2 0810.03.2326 ce 0 J Z 0 ceZ w F MPROVEMENTS >- w w ce w C0 0 z J z 1.1.1 0 w AIP NUMBER 3-53-0058-045 0 F- 0 Z DATE OCTOBER 19, 2012. ISSUED 100% CD PROJECT ARCHITECT Jti PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2326 DOOR TYPES i FLUSH SCW W/ RECTANGLE LITE AND 4 PANELS Ill/ SAFETY GLAZING W/ OBSERVATION PORT BUSH SCUD 1 LITE W/ 2 PANELS 111/SAFETY GLAZING c EXTERIOR SINGE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET I ENTRY`' A 3'-0" x 6'-S" "' STAIN/ STAIN 1 -1W -I/ 716 DK -4 "' LOCK -1 1/421 2 STAIRWAY A 3'-0" x 6'-8" STAN/ STAN HW -1/ "Il6 DK -4 LOCK -1 1142.1 3 FAMILY ROC*15 3'-0" x 6'-S" STAN/ STAIN 1-1111-2/ 643E DK -2 LOCK -2 2/46.1 4 ENTRY C 3'-0" x 6'-8" 1/42.1 STAIRWAY C 31-0"' x 6'-8" 1/42.1 TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 5. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET., HEAD FLASHING DETAIL TYP. 3'1 1' - (E) ALUMINUM SIDING SACKER BOARD CAREFULLY LIFT (E) WALL UNDERLA'I'MENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SI4EATI4ING LAP OVER METAL FLASHING AND EXTEMD SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADI- E JNCs' Km -elute SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLAYMENT CAREFULLY REMOVE AND SALVAGE (E) ALUMINUM SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY t TR/I. RE -INSTALL (E) SIDING:, ACC;ESSORiE6a, * BLOGKNG TO MATCH (E) PRE -PRIMED, GALV SHEET METAL CAP FLASNNG UNDER SELF -ADHERING MEMBRANE. PAINT COLOR TO BE SELECTED IN TI -E FIELD CONTNUOUS SEALANT 5EI4ND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN: SELF ADHERING MEMBRANE (E) EXTERIOR SI IEATI4UJG TOUCH UP PAINT, AS REGI'D CONTINUOUS SEALANT, TYR SOLID.. WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE CAREFULLY LIFT (E) WALL IMERLAYMENT AND INSTALL TOP EDGE OF ELFADI-TERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADI -HERB MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING MEMBRANE DOOR HEAD CAREFULLY' REMOVE AND SALVAGE' (E) ALUMINUM SING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. RE -INSTALL (E) SIDING, ACCESSORIES, 4 BLOCKING TO MATCH (E) PRE -PRIMED FF GALV SHEET METAL FLASHING: UNDER SELF-ADI-IERRING MEMBRANE. EXTEND FLASHING 4" UP WALL (E) BACKER BOARD SHIM BACKER BOARD AS REQUIRED (E) WALL-UNDERLAYi1ENT SELF ADI-ERINCs MEMBRANE (E) E)crEpaene 6I4EATI4NCs —TOUCH UP PAINT, AS REC,3'D CONTNUOUS SEALANT, TYP. EXISTS FRAMING CONTINUOUS SEALANT BEHIND Z 5AR MAME STORM DOOR PER SCHEDULE KERF AS. REQUIS ED FOR WEATHER STRIPPING INSTALLATION SOLID' WOOD TRIM $NIh1 AS NECESSARY F LL GAP W/ BATT INSULATION JAMB BEYOND 1100D DOOR PER SCHEDULE' DOOR $140) 2" MIN. DOOR SWEEP OAK AND METAL THRESHOLD ADJUSTABLE SWEEP EXISTING: FLOOR STRUCTURE SILL IN READ OF SEALANT DOOR JAMB DOOR SILL ALUMINUM SIDING 3"_ 1,_a, DOOR DETAIL SET SHIM AS NECESSARY FILL. GAAP W/ BATT INSULATION BACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME TOUC14 UP PAINT, AS RE= CONTINUOUS SEALANT, TYP. SURFACE APPLIED CONTINUOUS WEATHER STRIPPING KEW IN CONTINUOUS IUEATI4ER STRIPPING SHIM AS NECESSARY FILL GAP W/ BATT INSULATION I3ACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME 8Ui' ACE APPL IED CONTINUOUS ILEATHER STRIPPING KEIF IN CONTINUOUS MATHER STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE AUTOMATIC DOOR SWEEP DOOR HEAD INTERIOR DOOR PER SCHEDULE DOOR JAMB DOOR SILL EXISTING FRAMING TOUCH UP PANT, AS RECTO =NT NOUS SEALANT, TYP. ---- SOLID WOOD TRIM DOOR PER SCI4ED.E INTERIOR DOOR DETAIL SET -, REVIEWED FOR CODE COMPLIANCE r APPROVED FEB 14 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 0 7 2013 3ERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (20 8) 624-2777 • FAX (208)';624-2973 OCTOBER 19, 2012 0810.03.2326 ce O z 0 z z 0 0 C. z MPROVEMENTS AIP NUMBER 3-53-0058-045 z 0 z DATE OCTOBER 19.2012 ISSUED 100% CD PROJECT ARCHITECT J 0 PROJECT MANAGER ML&TF DRAWN L'8 & C' -P DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.2326 NEW 4x0 HEADER WINDCX11 ASSEMBLY PER SCHEDULE a) MEW OR (E) 2x TO SUPPORT NEW HEADER EA. SIDE (1) NEW OR (E) FULL 1 -IT. STUD EA. SIDE NUJ OR (E) 2x CRIPPLE STUDS AT 16" O.C. NOTE: FIELD VERIFY ALL DIMENSIONS HEADER FRAMING DETAIL AT WINDOW F (INTERIOR) 1" = 11 - 0" (E) BActeR BOARD (E) SIDNG CARERILLY LIFT (E) WALL UNDERLAYMENT AND WALL SELF-APHERIN5 MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAMENT OVER PENETRATION FLASHTYP AT HEAD AND JAMBS. RENOVE (E) SIDING FOR INSTALLATION OF VENT FIXTURE AND FL-AS.14Na REPLACE OR RE INSTALL SIDING AS REQ'D TO MATCH (E) PRE -PRIMED, GALV 51-IEET METAL FLAWING W/ Ff. END CAPS LNDER SURFACE MOUNTED IttEGLET AND CAP FLASHING. PAINT COLOR TO E SELECTED IN THE FIELD PANT VENTILATION HOOD, COLOR TO SE SELECTED IN THE FIELD EXTERIOR:VENTILATION WOOD. REF. MECI4.- PAINT INTERIOR WI ACCUSTICAL oAr1pir4 COMPOUND. SET N MASTIC AT EXTERIOR TRIM. SELF ADHERING BITUMINOUS MEMBRANE FLASHING (E) EXTERIOR SI-EA1I4ING IX BLOCKING 2X2 BLOCKING, 4 SIDES (RT.) REPLACEMENT SIDING AS REQUIRED UNDETERMINED SONG SUBSTRATE IX BLOCKING MECI4 UNIT MD DUCTS - REF MECI-IMICAL HOLD TIGHT TO STRUCTURE CONTINUOUS VIBRATION DAMPENING PAD RE: MECHANICAL 12X16" ACCESS HATCH FOR MAINTENANCE 24 CONT. NAILER WHERE tuon4 or SOFFIT EXCEEDS 16", INSTALL 2X4 STUDS 16" O.C. 5/6" Gus- PAINT TO MATCH (E) TEXTURE 4 COLOR Cif alum& CEILI1+6 MOUNTING BRACKET °' X Ili" ANGLE IRON LEG BOLTED TO (E) STRUCTURE (E) INTERIOR WIDE TRIM PHOTO TYP. NTS EXISTING CEILNG STRUCTURE (E) WALL FIRMING BLENDING AIR UNIT DETAIL 311 = 1' - 0" 5/8" GUIS- TEXTURE 4 PAINT TO MATC1-1 (E) ADJACENT CONSTRUCTION. 2X WOOD FRAMING di 16" o. BLENDING UNIT 24" x 24" ACCESS HATCH 77 / BLENDING AIR UNIT DETAIL 3" = 1' - 0'1 NOTE: REMOVE EXISTING SMOKE pErEcToRs, CUT AND PATCH aturda45 REQUIRED- REMOVE ALL PAINT. LINES, PROVIDE SHEET ROCK., TAF'E MD TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCI-I SURROUNDING CONDITIONS. 7 if CEIL.NG MOUNTING !BRACKET ANGLE IRON LEG BOLTED TO (E) STRUCTURE MECH UNIT AND DUCTS - REF MECHANICAL HOLD TIGHT TO (E) CEILING STRUCTURE ABOVE CONTINUOUS AERATION CIAMPENIF4 PAD RE: 'MECHANICAL WERE WIDTI4 CF SOFFIT EXCEEDS 16", INSTALL 2X4 STUDS 16" O.C. 5/8" GUS-. PAINT TO MATCH (E) TEXTURE 4 COLOR OF �1u. 2x2 CONT. NAILER 1611)(164 ACCESS HATCH FOR MAINTENANCE REVIEWED FOR cODE COMPLIANCE APPROVED FEB 14 ,,w RECEIVED CITY OF TLIKWIL FEB 0 7 2013 pERMIT CENTER & DE WALL \*4) t°150 Sar) DETECTOR INSTALLATION DETAIL TYP. 3" = 1' - 0" S.MSTEMPER ARCHITECTS A Prof essional Limited Liability Company 4000 DELR1DGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 OCTOBER 19, 2012 0810.03.2326 0 z 0 z w z 0 0 z MPROVEMENTS AIP NUMBER 3-53-0058.045 0 DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT Jo PROJECT MANAGER ML&TF DRAWN LB&CP MISC, DETAI LS A2.2 0810.03.2326 LIT (E) WALL UHPERLAYMENT AWAY LOOSELY FROM (E) SI4EATI411.6 AT JAMBS AND I4E41D NOTE: ftEmove (E) sIrDiz BACK PROM R.O. AS REM, (E) SIDING NOT SI-IOUN FOR CLARITY. REPLACE A I ' OR INSTALL. NEW SIDING AFTER Mk11E3R.ANE FLASHING HAS SEEN INSTALLED. LAP SILL MEMBRANE FLASHING 24/2" OVER (E) BLDG. PARER AT SILL. EXTEND 1 BEYOND R.O. AT EA END OF SILL UNDERLAYMENT AT SILL (E) SHEATHING CUT SILL FLASHIN6 TO EDGE or R.O. AS S14011FL ADHERE l'EMSRANE FLASI-ING TO OUTSIDE FACE OF WALL SI4EATI-1114G MIN INITTERFLY CORER FLASHING MEMBRANE FLASHING AT SILL SCALE: NTS LiFr (E) BLDG. PAPER AWAY LOOSELY mom (E) 51-1EATI4NG AT JAMBS AND I-IEAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REM, (E) SIDING NOT SHOWN FOR C.LARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL EETUEEN FLASHING AND LUNDOW FLANGES. SEALANT SHOULD FLOW CUT BEYOND EDGE OF WINDOW FLAW:se AND SHOULD FILL FLANGE NAIL HOLES. 12EMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) WALL LINIDEIRLAYMENT AT SILL. 1 il A 0 0 0 0 0 \ \\\ 0 0 / ELEVATION VIEW MEM13RANE FLASHING PREVICUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOM OVERNAIL FLAE, HEAD CNLY. 11 NOTE: INSTALL WINDOW FER t•IFG'RS SPECIFICATIONS. NOTIFY' TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION SCALE: NTS REMOVED EDGE OF (E) SIDING, &NOUN DIAr.sRAMATICALLY. (E) SING NOT 51-1OLLN FOR CLARITY_ LAY (E) WALL UNDERLAYMENT BACK DOWN OVER FLANGE FLASHNG AT JAMBS NOTE: REMOVE (E) SIDING BACK FRCM (E) R.O. AS REQD (E) SIDING NOT SI -10U14 FOR CLARITY. REPLACE AND OR INSTAL -I_ NEW SIDING AFTER MEMBRANE FLASHING 14AS BEEN INSTALLED. r WHERE RECINED, -nem (E) WALL 1 UNDERLAYMENT AT HEAP TO PREPARE FOR INSTALLATION OF HEAP FLO4114G AND WINDOW TRIM (FOLLOLIWG STEPS). (E) WALL UNDERLAYMENT NOTE: REMOVE (E) SIDING BACK FROM (E) R. AS REQ'D (E) SIDING NOT SHOLLN FOR CLARITY. REPLACE :AND OR INSTALL NEW SIDNG AFTER MEMBRANE FLASI-1114(i HAS BEEN INSTALLED. ,-- CUT JAMS FLASHING TO 7 ...."..,,,,...„,.....7„.„--- , _........ EDGE OF WINDOW OPENING AS SHOW. EXTEND I-1/2" ''-'- -.1j1/21rrp. BEYCiND EDGE OF OPENING AT HEAD: JAMS: AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF UJALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.Q. AS REQ'D (E) SONG NOT 51401N FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER ME113RANE FLASHING HAS BEEN INSTALLED. — INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHNG. INSTALL SI -IT. METAL HEAP PLAS1-111s6 UNDER (E) BLDG PAPER. NOTE: REMOVE (E) SONG SACK FROM (E) O. A5 MOD (E) SIDING NOT SHOUN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 11•••-.ien,1••••,,,, TRimmEr) EDGE OF (E) SIDING, SHQUN DIAGRAMATICALLY. (E) SIDING NOT SI4CON FOR CLARITY. ALLOW life CLEARANCE BETWEEN FLAsi-liNa AND ear. axle (£) SIDING. HEAD FLASHING INSTALLATION SCALE: NTS (E) WALL UNDERLATMENT --" ••• CUT HEAD FLASHING TO EDGE OF WINDOW OPENING AS SHOLLN. EXTEND 1-1/2" BEYOND R. AT HEAD AM JAMBS. Apen FINETRATION, FLASHING. TO OUTSIDE FACE OF WALL 014EATHING (TYP. EACH SIDE WALL) (Th MEMBRANE FLASHING AT HEAD 3 SCALE: NTS NOIE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SR:** NOT SHOLLN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASI-111,4 I4A6 53EEN INSTAL -ED. INSTALL 14EAID FLANGE PLASHING OVER WIDOW NAILING FI -ANG AND PLASHING. NEM L WINDOW FLASHING INSTALLATION SCALE NTS (E) BLPCs. PAPER BENEATH SIDING INSTALL WO. TRIM. BUTT TIGHT TO TRIMMED EDGE (E) SONG. APPLY SEALANT BEAD TO JOINT BETUEEN WINDOW TRIM ANC)SlDl WOOD TRIM INSTALLATION SCALE: NTS LEAVE 1/4"-3/8" GAF' EETUEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: I: MEMBRANE FLASI4ING IS SPECIFIED IN VI (22 00 AS 'SELF API4EARING MEMBRANE FLASI4ING" TYPICALLY REFER TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION DETAILS "5 AND 6" REFER 70 MEMBRANE INSTALLATION AFTER WINDOW WAS BEEN SET IN PLAr-E, SHIMMED, AND :4514040RED. 4 DETAILS 1 AND 131' REFER 70 SHEET METAL HEAD FLASI-ING. 5: DETAIL SIGEFERS TO 11,1000 TRIM AND CAULK JOINTS. REVIEWED FOR CODE COMPLIANCE APPROVED . FEB 14 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIU-, FEB 0 7 2013 i3ERIVIIT CENTER W0 S.MSTEMF'ER ARCHITECTS A Profeasioarial Limited liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 88105 (206) e24 -2P77 • FAX (206) &24-2973 OCTOBER 19,2012 0810.03.2326 1:e 0 ce z Q z w ce KING COUNTY MPROVEMENTS AIP NUMBER 3-53-0058-045 0 DATE OCTOBER 19,2012 ISSUED 100% CD PROJECT ARCHITECT J 0 PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW FLASHING DETAILS A2.3 0810.03.2326 N \ / (E) BLPCs. PAPER BENEATH SIDING INSTALL WO. TRIM. BUTT TIGHT TO TRIMMED EDGE (E) SONG. APPLY SEALANT BEAD TO JOINT BETUEEN WINDOW TRIM ANC)SlDl WOOD TRIM INSTALLATION SCALE: NTS LEAVE 1/4"-3/8" GAF' EETUEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: I: MEMBRANE FLASI4ING IS SPECIFIED IN VI (22 00 AS 'SELF API4EARING MEMBRANE FLASI4ING" TYPICALLY REFER TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION DETAILS "5 AND 6" REFER 70 MEMBRANE INSTALLATION AFTER WINDOW WAS BEEN SET IN PLAr-E, SHIMMED, AND :4514040RED. 4 DETAILS 1 AND 131' REFER 70 SHEET METAL HEAD FLASI-ING. 5: DETAIL SIGEFERS TO 11,1000 TRIM AND CAULK JOINTS. REVIEWED FOR CODE COMPLIANCE APPROVED . FEB 14 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIU-, FEB 0 7 2013 i3ERIVIIT CENTER W0 S.MSTEMF'ER ARCHITECTS A Profeasioarial Limited liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 88105 (206) e24 -2P77 • FAX (206) &24-2973 OCTOBER 19,2012 0810.03.2326 1:e 0 ce z Q z w ce KING COUNTY MPROVEMENTS AIP NUMBER 3-53-0058-045 0 DATE OCTOBER 19,2012 ISSUED 100% CD PROJECT ARCHITECT J 0 PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW FLASHING DETAILS A2.3 0810.03.2326 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP FDF FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR w WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS SEATTLE RESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR X_ OR XX 0 X/Y '/ DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION -i , (73 EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES. ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.1 DETAILS M2.0 MECHANICAL FLOOR PLANS GENERAL NOTES 1. THEMECHANICALSYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK . INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL. SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE. WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD' VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER,AND CONTROL INTERFACE' AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. Q 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4'-O" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL X-X XX ABBR F--- DN F--- uP + f "6E------4- + r + C>a -�-I- 0 0 o0 - DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD RA/EA RG SA SA RA/EA SD VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH OR THERMOSTAT EQUIP IDS EQUIPMENT LOCATION NG • 0 erM MOD NG MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT • MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32"Lx12.25"Wx8.5"H 76 120 23 26 23 26 N/A 23 26 N/A BV -1, 2, 3 BLENDING UNIT VENTILATOR 120 1 X 32"Lx1225"Wx8.5"H 76 X 1 1, 2, 3 X 90 1,2 - SWITCHES (ON, TIMER) 120 1 1, 2, 3, 4 X 90 X 7" 7" X WALL CAP 1 OG -3 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08" WG 4" 4" REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 115 .5" WG 32"Lx12.25"Wx8.5"H 76 120 1 1, 2, 3 BV -2 140 .5" WG 32"Lx12.25"Wx8.5"H 76 120 1 1, 2, 3 BV -3 140 5"` WG 32"Lx1225"Wx8.5"H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 1 SG -1 115 <.08" WG 7" 7" WALL ALLGRILLE 1, 2, 4 SG -2 140 <.08" WG 8" 8" WALL ALLGRILLE 1, 2, 4 SG -3 140 G0" WG 8" 8" WALL ALLGRILLE 1, 2, 4 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 OG -2 90 <.08" WG 7" 7" WALL WALL CAP 1. 2, 3, 4 OG -3 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08" WG 4" 4" WALL DECO 1, 2, 4 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 5. BASIS OF DESIGN. SHOEMAKER 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE A. OR APPROVED EQUAL. 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 6. PROVIDE WITH AN OPPOSED BLADE DAMPER 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. WAC RESIDENCE CODE FLOOR AREA (SQ. FT.) NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2326 BV -1 742 1 90 CFM 90 CFM 1 0810.03.2326 BV -2 931 2 90 CFM 90 CFM 1 0810.03.2326 BV -3 275 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED' PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51-51-1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R-8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING R-8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R-8 1,3 IN CEMENT SLAB OR IN GROUND R-5 1,3 NOTES: 1. THICKNESS OF INSULATION 1S DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR. 3, REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 011101 AND 028200 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT/SWITCH HOURS OF OPERATION SET BV -1 SWITCH TO OPERATE 1 OF EVERY 3 HOURS. SET BV -2 SWITCH TO OPERATE 1 OF EVERY 2 HOURS.. SET BV -3 SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION BV -1 PER SRC M1508.3 QF = QR / (&EGR X QR = (FROM TABLE &EGR = VENTILATION F = FRACTION OF F) 1508.2) Q EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 OPERATION La QF = XX / (1 X 1/3) = 90 CFM MECHANICAL VENTILATION CALCULATION BV 2. 3 PER SRC M1508.3 QF = QR / (&EGR X F) QR = (FROM TABLE 1508.2) la &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = XX / (1 X 1/2) = 90 CFM RECEIVED CITY OF TUKWILA FEB 0 7 2013 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED S.M. STEaMPER ARCHITECTS 4000 DELRIDGE WAY SW SUITE 200 • STA'!TLE, ICA 98106 (200) ea4-2777. FAX (200) 624 -tion THE GREENSUSCH GROUP. INC ACC etw. VIDEO a MECIO 1900 wear SIEE1 SLOE 22 MU* tern (200) 370-0009 (200) 373-0441 FAX MPROVEMENTS 0 ce ct 0 Ct AIP NUMBER 3-53-0058-45 DATE 09/10/2012 TUKWILA WASHINGTON ISSUED 100% GD EXPIRES: 9/08/2014 PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 081003.2326 CLOSET LANDING CHASE, REFER TO ARCHITECTURAL. SG -1 INSTALL BLENDING UNIT VERTICALLY IN CHASE 7"0 FAMILY ROOM BASEMENT MECHANICAL PLAN SCALE: 1/4" = 1'-0" BASEMENT BV -1 BV -2 BV -3 KEY TO VENTILATION ZONES SCALE: NONE NORTH GAS METER UPPER NORTH LOWERED SOFFIT, REFER TO ARCHITECTURAL SEE (E)SG DINING ROOM KITCHEN REL ATE E LIGHT E THERMOSTA QG-2 4) 90 BV -2, SEE LIVING ROOM (E)SG DRAWING NOTES: NORTH 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SRC M1508.6.6. 2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. SEE BEDROOM 4 SEE TYP ALL WALL GRILLES -� BEDROOM 3 SG -1 2 5 140 ., 4 8"0 7"0 `ABV 3� RG -1 25 TYP \._DV -3, SEE UPPER FLOOR MECHANICAL PLAN SCALE: 1/4" = 1'-0" FLAG NOTES: DV -1 AND DUCTWORK ROUTED IN CHASE. BV -2 AND DUCTWORK ROUTED IN SOFFIT. BV -3 AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCHES WITH TECHNICAL REF'RESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFIEATIONS SECTION 260010. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER SRC M1508.6.4.COORDINATE FINAL ':WITCH LOCATION WITH HOMEOWNER. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHI ViG AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND. TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEI:*JLED. REFER TO THE MINIMUM DUCT INSULATIO1 THICKNESS SCHEDULE ON M1.0. 1R1TH' 3 TYP SEPARATE PERMIT AND Y 4 PRQVAL CURED RECEIVED CITY OF TUKWIL, . FEB 0 7 2013 ERMIT CENTER EXPIRES: 9/08/2014 S.M. STEMPER ARCHITECTS A Professional Waited Company 4000 DELRIDGE WAY SW OTTE 200 SEATTLE, WA 96108 (eoe) 1184-2777 • FAX (208) a24--2072 THE GREENBUSCH GROUP, INC _ 000115 c ..siuo_/ VIM 41IEaIA11d�L E11NIEER111G ler 1MIEN 4111E 901 MD= I& 10110 (206) 37e-0569 (206) 375-0611 FAX MPROVEMENTS 0 FT NOISE R 0 AIP NUMBER 3-53-0058-45 TUKWILA '1 1ASH INGTON DATE 09/10/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAW' JA, DT MECHANICAL PLANS M2.0 0810.03.2326 SUPPLY AIR DUCT MOTOR ACCESS FILTERS ACCESS OUTSIDE AIR DUCT RETURN AIR DUCT INSTALL GRILLE LOW INSTALL UNIT VERTICALLY IN CLOSET HOLD TIGHT TO STRUCTURE 1� HOLD TIGHT TO STRUCTURE NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 3. INSULATE ALL DUCT AS SCHEDULED. GBV -1 INSTALLATION DETAIL I SCALE: NONE SHEETMETAL TRANSITION TO WALL CAP NECK SIZE 2X BLOCKING FOAM BACKER ROD WALL CAP DUCT PER PLAN CAULK 2X BLOCKING SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS. (E)CEILING OUTSIDE AIR DUCT RETURN AIR DUCT FILTER ACCESS COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE SUPPLY AIR DUCT SOFFIT MOTOR ACCESS NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. BV -2 INSTALLATION DETAIL SCALE: NONE CAULK SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN 2X BLOCKING 2X BLOCKING FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. MOTOR ACCESS FILTER ACCESS RETURN AIR DUCT OUTSIDE AIR DUCT ATTIC HOLD TIGHT TO STRUCTURE BV -3 SUPPLY AIR DUCT NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE BV -3 INSTALLATION DETAIL SCALE: NONE D �3- ost) SEPARATE 1, :PRO PE °MIT AND ,AL RECEIVED CITY OF TUKWIL, FEB 0 7 2013 PERMIT CENTER EXPIRES: 9/08/2014 S.M. STEMPER ARCHITECTS A Protemionel luted Liabilk7Covapanr 4000 DELRIDGE WAY SW SUITE 200 SF,.TTLE, WA 98106 (206) -em • FAX (206) 624-2079 THE GREENBUSCIi GROUP, INC AC4318924. NM a MECHANICAL t MIG 1000 lM MO sir MAE 201 sari IN 0611* i2) 376-0569 (206) 316-0641 FM 0810.03.2314 KING COUNTY INTERNATIONAL AIRPORT MPROVEMENTS 0 RAFT NOISE R RESIDENTIAL AIR AIP NUMBER y 3-53-0058-45 SEATTLE WASHINGTON DATE 09/19/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER CO DRAWN JA. DT DETAILS M2.1 0810.03.2326 NORTH LOCATION: SER „1NG: 201240 VOLT, SIDE OE 10000 CKT PE K' A PHASE EXISTING LOAD EXISTING LOAD TING LOAD TIN NC LOAD TII'G LOAD 15 EXISTING LOAD 17EXISTING LOAD 9 P€ASE, 3 WIRE.. AMP with MN ilii €EC IPTION LOAD EXISTING LOAD EXISTING ,TING LOA EXISTING LOAD EXISTING LOAD EXISTING LOAD EtISTING LOAD STING LOAD TING LOAD EXISTING LOAD BLENIGUNITS 9 SPACE' LOAD TYPE 2011 20/1 D €I STING LOAD STING LOAD LI. ELECTRICAL L N.. Strea DESCRIPTION SYMBOL DESCRIPTION IG LIGHTING OR POWER PANEL EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANti CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WRING AND CONDLI T SIZE MAY NOT APPEAR ON . PROVIDE CONDUCTORSAND CONDUIT PER NEC CODE. 12 AWG, 1/2"C MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. MAST, WEATH EADS�, a 0 DAMPER CONNECTION Q' ' NON-FUSED DISCONNECT SWITCH TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN _..ELECTRICALM @ SMOKE DETECTOR TIMER OPERATE) SWITCH — - — AERIAL SERVICE CONDUCTORS,ATE WITH UTIUTT CEILING MOUNTED FIREALARM-VISUAL STROBE LIGHT ! T - THERMOSTAT UNE VOLTAGE FIRE ALARA SM /CARBON MONOXIDE DETECTOR RrIpille TOTAL LOADS COMPUTED LOAD' Q ISOLATED GROUND BUS RAIN TIGHT NEIA-2R ENCLOSURE 03 0 FEED TI -IRU LUGS DOUBLE LUGS KVA 0 ■ 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE UMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5:00 PM. 4, WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES RE';'LACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING ' CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AN[: PATCH CBLING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE ANI:) PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDI11ONS. ELECTRICAL PLAN NOTES 10 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. 0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. SEE FLOOR PLANS FOR LOCATIONS OF BLENDING UNITS AND TIMER SWITCHES. \\V 2#12NMB +G, OR EQUAL MP 2#12NMB + G, —..•'' OR EQUAL RECEIVED CITY OF TUKWIL.= FEB 0 7 2013 PERMIT CENTER SEPARATE PERMIT AND APF,ROVVAI aliED S. 1_. P ice' ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 08106 (206) 624.-2777 • FAX (206) 624-2972 ■NSIIItiils. IMO 4110 MOM PM IR %OM $01164121 PRO SIM if SIVIS 0810.03.2326 ct 0 ce 1 z 0 LU c Z KING COUNTY MPROVEMENTS AIR NUMBER 5-53-0058-045 Z O H z CO DATE SEPT' 17, 2012 ISSUED 95% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN BCR FLOOR PLANS NOTES E1.0 0810.03.2326