Loading...
HomeMy WebLinkAboutPermit D13-071 - GOOD FEET - TENANT IMPROVEMENTGOOD FEET 17055 SOUTHCENTER PY D13-071 City AI/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov • DEVELOPMENT PERMIT Parcel No.: 2623049069 Address: 17055 SOUTHCENTER PY TUKW Suite No: Project Name: GOOD FEET Permit Number: D13-071 Issue Date: 04/08/2013 Permit Expires On: 10/05/2013 Owner: Name: KTM GROUP LLC Address: 635 HIGH SCHOOL RD NE , BAINBRIDGE ISLAND WA 98110 Contact Person: Name: MARK PETERSON Address: 909 112 AV NE, SUITE 206 , BELLEVUE WA 98004 Phone: 425-641-9200 Contractor: Name: D P INC GENERAL CONTRACTORS Phone: 206-361-2989 Address: 19909 BALLINGER WAY NE , SEATTLE, WA 98155 Contractor License No: DPINCGC066BU Expiration Date: 01/31/2014 Lender: Name: JPC ARCHITECTS Address: 909 112 AV NE, SUITE 206 , BELLEVUE WA 98004 DESCRIPTION OF WORK: LANDLORD PORTION: MINOR TENANT IMPROVEMENT, NON STRUCTURAL, DEMISING WALL, ADDING RESTROOM FOR 2800 SQ FT, NEW BUILDING STANDARD ENTRY DOORS, RELOCATION OF EXISTING LIGHTING FOR NEW WALL. Value of Construction: $35,000.00 Fees Collected: $1,215.02 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY **continued on next page** doc: IBC -7/10 D13-071 Printed: 04-08-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non -Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: //0 r// 3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perf9rmanc- of work. I am aut oriz d to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: oaf Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non -building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D13-071 Printed: 04-08-2013 7: All construction shall be done in conform with the approved plans and the requiremEof the International Building Code or International Residential , International Mechanical Code, Washingto to Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ***FIRE DEPARTMENT CONDITIONS*** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IPC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) doc: IBC -7/10 D13-071 Printed: 04-08-2013 25: Aisles leading to required exits shall bEilvided from all portions of the building and tikquired width of the aisles shall be unobstructed. (IFC 1013.4) 26: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 27: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NEPA 13-8.6.5.3.3) 28: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 29: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 31: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 32: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 34: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) (17055 SOUTHCENTER PKY) 35: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 36: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 37: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. doc: IBC -7/10 D13-071 Printed: 04-08-2013 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 1)0( Project No. Date Application Accepted: Date Application Expires: _ 9-I ( 3 (For office use only)- CONSTRUCTION nly)- CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: VtITUVelOV► V/A3(t(/l� ViiN 1 Tenant Name: ('oobp PIO,( King Co Assessor's Tax No.: Suite Number:'1pj(/ PROPERTY OWNER Name: vIth1 iftouri GOYUIIAAwA0 V Addresswy P4 WI City: ojtuott Ate: lbs CONTACT PERSON - person receiving all project communication Name: ,AA, vie n(� -� Address: lot /1_ % 'J24 It24"" p v Nt, i City: twowro State: t�M Zip1D0A �R Phone: )e 1041. �'J_O Fax: UiYLLt Email: \MAAAPCl @i. Ini 1CAA • GENERAL CONTRACTOR INFORMATION Company Name: it pp U• Company Name: _thy y Ar, _ _I�, _�' Address: � V1CI QPi 1kl I Ns/ City: Stat %rair v Wer Zip oiei Phone: 51) t/trA. Fax: )N)l State: ia nAZip:l$OD Pii Contr Reg No.: Exp Date: Phone:: v vii el �0D Fax: Tukwila Business License No.: Email:rnal/W D a' t9p4U/!/I H \AppbcmIons\Forms-Apphcauons On Lm0201 I AprI canons\I'crnnl Apphcatum Revised - 0-0-11 docs Revised: August 2011 bh Floor: New Tenant: ❑ Yes ❑ .. No ARCHITECT OF RECORD �,�" ,�, Name: N • P1 tit 1`�'i eiro Company Name: _thy y Ar, _ _I�, _�' Architect Name:/ r I Address:A0l it1 '_r i 0..6City:41�'evvP,_ )N)l State: ia nAZip:l$OD Pii Address: Phone:: v vii el �0D Fax: Email:rnal/W D a' t9p4U/!/I km ENGINEER OF RECORD �,�" ,�, Name: N • P1 tit 1`�'i eiro Address: P\ Oak 1\1-+- kvfo. / CA1Ivo f)0t. Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) �,�" ,�, Name: N • P1 tit 1`�'i eiro Address: P\ Oak 1\1-+- kvfo. / CA1Ivo f)0t. City: '1 _Aim State: tA'11\181 Zip:Am A Page 1 of 4 BUILDING PERMIT INFORMATIO— 206-431-3670 Valuation of Project (contractor's bid price): $ %. IPTD Describe the scope of work (please provide detailed information): VV\ V% v ' 1T -~'i 1 VVVIMI1 (AlbfAri, NSU tC V 2 , ¶'Y/KM SSI 136, 1014, — W(s V4MIThiriKA •f v (V �. qb Da ) NfrAN \071A) - operKz D f,01 -9/%-c t)p-b-r-o V9vib7A'n 1 41GSI\ tJ(v (j1( 't I f& fAIJItit1P►' A' 4 C hif 1 O Existing Building Valuation: $ Will there be new rack storage? ❑ Yes .. No if yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building?. ❑ Yes 1221' No /f "t•Cs attach list of materials and storage locations on a separate S-1/2" x I I '• papa- including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applicatiot s\Forms-.Applications On Linc\20I 1 Applications\Permit Application Rcviscd - 8-9-I Ldocx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I" Floor 0.60OD C6 , N'D v- b in t 2- Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building?. ❑ Yes 1221' No /f "t•Cs attach list of materials and storage locations on a separate S-1/2" x I I '• papa- including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applicatiot s\Forms-.Applications On Linc\20I 1 Applications\Permit Application Rcviscd - 8-9-I Ldocx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AN I 4 INED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Signature: HORIZED G Date: 00).01. 0,619) Print Name: um, VvirokotRJ Day Telephone: %. 1,/1. 1040 Mailing Address: 01101 tk'nn u43 f Y t Oo 5Vl/ av,(tAhiv �0 zin H. 1Applieations1Forma-Applicanon, On 1,111,n2011 Apphcat ,o kI' rmn AppI m..' Reviled - $.n -I I.docx Rcvi.,cd: Aucust 2011 bl City State Page 4 of 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 2623049069 Permit Number: D13-071 Address: 17055 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 03/01/2013 Applicant: GOOD FEET Issue Date: Receipt No.: R13-01235 Payment Amount: $738.15 Initials: LAW Payment Date: 04/08/2013 09:34 AM User ID: 1632 Balance: $0.00 Payee: KTM GROUP LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1060 738.15 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 733.65 640.237.114 4.50 Total: $738.15 Drintarl• nd_fR_/ni • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 2623049069 Permit Number: D13-071 Address: 17065 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 03/01/2013 Applicant: GOOD FEET Issue Date: Receipt No.: R13-00945 Payment Amount: $476.87 Initials: WER Payment Date: 03/01/2013 01:51 PM User ID: 1655 Balance: $738.15 Payee: MARK PETERSON TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 001207 ACCOUNT ITEM LIST: Description 476.87 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 476.87 Total: $476.87 PrintArl• f13-01-9013 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 �t3- ,7) Project,.Type_of,lnspection: � G � r -e . fi iv A- \ (3J , ti0 fAec, Address: 5[f�� /p�� kovy Date Called: Special Instructions: 0(0 15--- 1 4 — (9( Date Wanted:. a.m. –(3 Requester: Phone No: ErApproved per applicable codes. EllCorrections required prior to approval. COMMENTS: D 1Z & VQ -5 1 i, .t' .+ Inspector: Dater 3 3 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Di3-®-7! PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 y...16, (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project-.., Tyne of Inspection: : A/AA is,). l &46 2. 00,6 �-e- Address: 1 70Sic ,Sc_pktkLuAq Date Called: Special tnstruuc�tiioris:�j 9 f 0 CO Date Wanted:. 5-3 13 a.m. rell• Requester: Phone No: -2A 6 —35(e-21 7/0 JApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: l - " 7 _Q OD U tr\A-- pk-ok. - ------- -''"U_- N.) t() o o vJ ry or *to\Ak CetsA01\61 I i', s Inspectol: Date: C t.3 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G� 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 ,D13 -d7 ( Prot ; Type of Inspection: Address: _ 1' o � S sc_ A Ai a Date Called: I �z-.'R�► � Special Instructions: N Date Wanted:. -4 -2; i --(3 p.m. Requester: Phone No: / Approved per applicable codes. Corrections required prior to approval. / COMMENTS: P //`/ 2 r, A h Inspe'ctor: Date - 4 I.3 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 D13 —Ori I Project: Type Inspection:w. Ad19s:Os ttJJ PArK ,' Wv Date Called: ,..-- Special Instructions: 1 Date Wanted:. a.m. Requester: Phq.e No:6 . ((o EjApproved per applicable codes. Corrections required prior to approval. COMMENTS: • 5 ,./10,5 e4-2 c_J(kr r Inspector: 1 I' Date: n REINSPECTION FEE REQUIRED. Prior to next inspection; fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /3— 5— 4.)q4r, 013—Q7d PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407. Project: 6,-0---d —� ,� 5/303 Ty e Inspection: Hood & Duct: 5keof Address: j -los-� Suite #: �- � Contact Person: -L Special Instructions: \e(cf-.-) Phone No.: a` 4pproved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: 5/303 Fire Alarm: Hood & Duct: Monitor:Pre-Fire: ;fes -..i:i -L --ok Needs Shift Inspection: Sprinklers: 5/303 Fire Alarm: Hood & Duct: Monitor:Pre-Fire: Permits: Qccupancy,.Type: I - .,,; ; Inspector: 1‘,/".1-C/ . �- 5/303 Date: Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit ht - 07' 13-5—�0 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: �', Sprinklers: Fire Alarm: TyR f Inspection: _ Address: 1 Suite #: )0S -S- " S p`�c, lJ` Contact Person: Special Instructions: C-TrU - oil- Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: SP Crov-e- oK Occupancy Type: Sf) C-TrU - oil- , 00 P/PAN_S 1 00 S i 4-e ., Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: _ Occupancy Type: Inspector: / 2-t C,,L f—' Date:/y/dV//3 Hrs.: I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 'LUU9 wasnington State tnergy Uoae Uompliance corm for Nonreslaentlal ana Multifamily Heslaentlal Interior Lighting Summary LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info ' Project Address 17065 Southcenter PKWY Date 3/25/2013 Tukwila, WA For Building Department Use FILE COPY 40. 98188 Applicant Name: .7Pc Architects Applicant Address: 909 112th Ave NE, Suite 206, Bellevue, WA 9 rir t Applicant Phone: 425.641.9200 Project Description ❑ New Building ❑ Addition ✓ Alteration ✓ Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option O Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed ✓ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan/room #) Occupancy Description Allowed Watts per ft2 ** Gross Interior Area in tt2 Allowed x Area ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Proposed Lighting Wattage Location (floor plan/room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed REVIEWED FOR CODE CO?RPLI NGF APPROVE City of Tukwila 6L�ILD9I'1 ! !ISION tts may not exceed Total Allowed Watts for Interior Total Proposed Watts Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. CORRECTION LTA,.._.._ D�3 RECEIVED CITY OF TUKWILA MAR 2 6 2013 PERMIT CENTER 2009 wasnington state Energy Code Compliance Form tor Nonresidential and Multifamily Residential Interior Lighting Summary (back) LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Prescriptive Spaces Occupancy: O Warehouse or Parking Garage QQ Other Qualification Checklist Note: If occupancy type is °Other and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T-1, T-2, T-4, T-5, T-8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw-in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <=150w c) electronic ballasts 3. LED lights. TABLE 15-1 Unit Lighting Power Allowance (LPA Us& LPA` (Wifte) Use' LPA` (W/ftz) Automotive facility 0.85 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking_garages 0.20 Courthouse 1.10 Penitentiary and other Group 1-3 Occupancies 0.90 Cafeterias, fast food establishments5, restaurants/bars5 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail70, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1-1 and 1-2 Occupancies 1.20 Transportation 0.80 Hotel/motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries5 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies' (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15-1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w/ft2 may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three -quarter -height partitions (transparent or opaque) and lighting for free-standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of furniture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling -mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. JPC ARCFIRTECTS March 25, 2013 City of Tukwila Building Division Tukwila, WA 98188 Attn: Allen Johannessen, Plan Examiner Re: Good Feet Permit number: D13-071 The following is the Architect's response to the permit comments from the City of Tukwila for permit #13 -105971 -BY. Architect's response is noted with BOLD letters. (1) Provide a door schedule with hardware notes that specifically identifies the type of door hardware and to show door hardware meets all ADA specifications. (IBC 1008.1.9 & 2003 ANSI 309.4) • Please refer to revised sheet 1-10.1 for added Door Schedule and Hardware Set information. (2) Provide dimensions for the restrooms showing the fixtures on the side of the toilet do not encroach on the required 5'0" clear space. Include interior dimensions of the bathroom. Provide dimensions for placement of toilet and sink fixtures with height dimensions. (2003 ANSI 604 & 604.3.2) 425 641 9200 • Please refer to revised Enlarged Plan -Restroom sheet 1-7.1 showing dimensions on the enlarged plan and notated clear floor space for required 5'0" clear space. Elevations have been dimensioned for placement of toilet and sink fixtures. CORRECTION U013% 011 909 112th Ave NE Suite 206 Bellevue, WA 98004 RECEIVED CITY OF TUKWILA MAR 2 6 2013 PERMIT CENTER www.jpcarchitects.com JPC ARCATECTS (3) Provide length and placement dimensions for the bathroom grab bars (2003 ANSI 604.5) • Please refer to revised elevations on sheet 1-7.1 for added dimensions for bathroom grab bars. (4) Provide notes on the plan sheet 1-3.1 for the Future Retail # 100, "This space not approved for occupancy until a separate tenant TI permit has been completed. An ADA compliant bathroom shall be required under the separate tenant TI permit." • Please refer to Plan sheet 1-3.1 and Cover Sheet 1-0.0 where this has been notated. (5) The plan calls for a ramp out the back side (west) of the store. Provide more specifications with dimensions to show how far the ramp extends out, height, width and slope. Show it will not interfere with any traffic or fire lanes on that side of the building. • Key note 14 — was intended to flag the general contractor as to facilitate extremely minor site work as required by installing (2) two new exterior doors and dealing with grade incongruities pertaining existing paving asphalt conditions that might be slightly above or below the proposed door threshold. Ramping was an inaccurate description to have utilized in our key note narrative. (6) Provide a The Legend on sheet I -CS specifies common path of egress per 2006 IBC. Change note for consistency to specify per 2009 IBC. 425 641 9200 • Please refer to revised sheet 1 -CS Exit Plan and Codes summary for updated note. 909 112th Ave NE Suite 206 Bellevue, WA 98004 www.jpcarchitects.com JPC ARCATECTS (7) Provide a completed 2009 Washington State Energy Code Lighting Summary form. The form is available on line at: http://www.neec.net/energy-codes (scroll down to the middle of the page). ■ Please refer to revised sheet Demo RCP & Reflected Ceiling Plan 1-4.1 for completed Lighting Summary form. Attached are the (4) sets of revised plans. Please let us know if you have further questions or concerns regarding the permit review responses provided above. Sin erely, ie M. Herring JPC ARCHITECTS 909 112TH Ave NE Suite 206 Bellevue, WA 98004 425 641 9200 ext 304 www.jocarchitects.com 1 Facebook 425 641 9200 909 112th Ave NE Suite 206 Bellevue, WA 98004 www.jpcarchitects.com March 14, 2013 City•of Tukwila 1 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Mark Peterson 909 112 Ave NE, Ste 206 Bellevue, WA 98004 RE: Correction Letter #1 Development Permit Application Number D13-071 Good Feet —17055 Southcenter Py Dear Mr. Peterson, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433-7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. Sincerely, 44 ' J" hall cian File Nb' D13-071 W:IPermit CenterlCorrection Letters120131D13-07/ Correction Letter #/.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: March 6, 2013 Project Name: Good Feet Permit #: D13-071 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following continents in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. 1. Provide a door schedule with hardware notes that specifically identifies the type of door hardware and to show door hardware meets all ADA specifications. (IBC 1008.1.9 & 2003 ANSI 309.4) 2. Provide dimensions for the restrooms showing the fixtures on the side of the toilet do not encroach on the required 5'0" clear space. Include interior dimensions of the bathroom. Provide dimensions for placement of toilet and sink fixtures with height dimensions. (2003 ANSI 604 & 604.3.2) 3. Provide length and placement dimensions for the bathroom grab bars (2003 ANSI 604.5) 4. Provide notes on the plan sheet I-3.1 for the Future Retail # 100, "This space not approved for occupancy until a separate tenant TI permit has been completed. An ADA compliant bathroom shall be required under the separate tenant TI permit." 5. The plan calls for a ramp out the back side (west) of the store. Provide more specifications with dimensions to show how far the ramp extends out, height, width and slope. Show it will not interfere with any traffic or fire lanes on that side of the building. 6. The Legend on sheet I -CS specifies common path of egress per 2006 IBC. Change note for consistency to specify per 2009 IBC. 7. Provide a completed 2009 Washington State Energy Code Lighting Summary form. The form is available on line at: http://www.neec.net/energy-codes (scroll down to the middle of the page). Should there be questions concerning the above requirements, contact the Building Division at 206-431-3670. No further comments at this time. CO` D COY PLA REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-071 PROJECT NAME: GOOD FEET SITE ADDRESS: 17066 SOUTHCENTER PY Original Plan Submittal Response to Incomplete Letter # _ DATE: 03-26-13 X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: I 3 t3 ng'Divisio UFire Prevention ❑ Public Works ❑ Structural n Permit Coordinator Planning Division DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03-28-13 Complete Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route tg Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions qp- DUE DATE: 04-25-13 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 0 pEtF COD-. COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-071 DATE: 03-01-13 PROJECT NAME: GOOD FEET SITE ADDRESS: 17055 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPATME TS: ,;3 Building l'vision S — —s3 Public Works Fire Preventionmi/A_ Planning bivision Structural n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Ly3 Incomplete DUE DATE: 03-05-13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 11,1 Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 04-02-13 Not Approved (attach comments) (kr REVIEWER'S INITIALS: DATE: Permit Center Use Only, CORRECTION LETTER MAILED: Departments issued corrections: Bldg [ Fire 0 Ping ❑ PW ❑ Staff Initials.�C!" Documents/routing slip.doc 2-28-02 • PLAN REVIEW CHECKLIST - (Nonstructural) By: Date: • Permit App. 0/3" 9 7/ IBC Edition 0 & State Amend. Project title: 000,9 Aine74— +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 0— Classify the building or portion thereof in accordance with Chapter 3 (—Determine the type of construction of the building in accordance with Chapter 6. O Determine if the location of building on the site and clearances to property lines and other buildings on the site plan are in accordance with code provisions. O Review for conformity with General building height and area limitations in accordance with Chapter 5. O Review for conformity with special detailed requirements based on use and Occupancy. O Review for conformity with Type of Construction requirements of Chapter 6. O Review for conformity with Fire and Smoke protection features of Chapter 7. O Review for conformity with requirements of interior finishes of Chapter 8. O Review for conformity with requirements for fire protection systems of Chapter 9. O Review for conformity with requirements for means of egress requirements of Chapter 10 O Review for conformity with requirements of accessibility in accordance with Chapter 11, and ICC A117.1 O Review for conformity with Washington State Energy Code. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ✓ In circle = topic has been reviewed for the application. X In circle = topic is not relevant to proposed scope of work. City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 03/25/2013 Plan Check/Permit Number: D13-071 7 Response to Incomplete Letter # ,/ Response to Correction Letter # #1 Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Good Feet Project Address: 17066 Southcenter Pkwy, Tukwila, WA 98188 Contact Person: Jamie Herring Phone Number: (425) 641-9200 Summary of Revision: Please see attached document with specific responses to corrections as asked. Thank you! Sheet Number(s): I-0.0, 1 -CS, I-3.1, 1-7.1, 1-10.1 ROGSVED ASRVOP TUKWf1:A 14M 2 6.20131 PiRMIT CENTER "Cloud" or highlight all areas of revision including date o revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on -(& H AppliicaiumaForms-Appliwi ions On Linv:12010 Appliicaiions\7-2010 • Revision Subminal.doc Revised: May 2011 Contractors or Tradespeople Per Friendly Page • General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name D P INC GENERAL CONTRACTORS UBI No. 601515833 Phone 2063612989 Status Active Address 19936 Ballinger Way Ne License No. DPINCGC066BU Suite/Apt. License Type Construction Contractor City Seattle Effective Date 1/31/1994 State WA Expiration Date 1/31/2014 Zip 98155 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status PATTICC034MH PATTISON CONSTRUCTION CO LLC Construction Contractor General Unused 7/8/1997 2/17/1998 Archived PATTICA066DQ PATTISON CONSTRUCTION & ASSOC Construction Constructstructr General Unused 3/18/1994 2/17/1998 Archived DODSOPI101JB DODSON PATTISON INC Construction Contractor General Unused 4/2/1990 3/26/1994 Archived ACECO'•179L0 ACE CONSTRUCTION Construction Contractor Carpentry/Framing Painting/Wallcovering 6/20/1983 6/16/1986 Archived VANSND*176B0 VAN'S NORTHWEST DRYWALL Construction Contractor Dry Wall Painting/Wallcovering 1/20/1983 11/1/1983 Archived ALLAMD'1846N ALL AMERICAN DRYWALL Construction Contractor Dry Wall Painting/Wallcovering 1 /15/1982 1 /15/1983 Archived Business Owner Information Name Role Effective Date Expiration Date DODSON, WILLIAM President 01/31/1994 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 6 Merchants Bonding Co (Mutual) WA28622 01/31/2013 Until Cancelled $12,000.0012/27/2012 5 DEVELOPERS STY & INDEMNITY CO 791078C 01/31/2008 Until Cancelled $12,000.0002/25/2008 01/22/2013 4 CBIC SA6377 01/31/2002 01/31/2008 01/31/2010 $12,000.00 01/09/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 17 Travelers Indemnity Company Th C0526D6516 01/31/2013 01/31/2014 $1,000,000.0001/30/2013 16 Charter Oak Fire Ins Co CO2B323322 01/31/2013 01/31/2014 $1,000,000.00 01/22/2013 15 DTCO26323322C0F12 01/31/2012 01/31/2014 $1,000,000.00 01/02/2013 httns://fortress.wa.gov/lni/bbip/Print.asnx 04/08/2013 U Z 3 0] Q X Author: JAMIE HERRING 0 Date/Time: 3/25/201 00 eet Clean Shell I Suites 17045 & 17055 Center Place Shopping Center Site Plan Scale: 1 "=30' PROJECT AREA OF WORK SOUTHCE\TE PAS <WAY FI ,ECOPY Permit No. Plan review approval is subject to errors and omissions. Apprual of construction documents does not autho:;ze th :v*,olation of any adopted code or ordinance. Receipt of approved Fiel PY is , t o ed: By /K Date: '4 City Of Ttbkwlla BUILDING DIVISION REVISIONS No changes shall be made to the scope of riork without prior approval of Tukwila Building Division. 1101 1:: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: echanIcal tectricai Iumbing as Piping City of Tukwila BUILDING DIVISION,,, Drawing Index: Sheet Number 1-0.0 1-0.1 I—CS 1-3.1 1-4.1 I-7.1 1-10.1 Sheet I itle Cover Sheet & Site Plan General Notes & Symbols Exit Plan and Codes Summary Demolition & Floor Plan DEMO RCP & Reflected Ceiling Plan Enlarged Plan — Restroom Door Schedule & Details Code Information: PROJECT ADDRESS: CENTER PLACE 17065 SOUTHCENTER PKWY SUITE 17065 TUKWILA, WA 98188 CONSTRUCTION TYPE: TYPE — V—B, FULLY SPRINKLERED ZONE: TUC TUKWILA URBAN CENTER OCCUPANCY: M RETAIL TENANT SQUARE FOOTAGE: (area of work) SUITE 17055 1 GOOD FEET SUITE 17045 1 FUTURE RETAIL* * THIS SPACE NOT APPROVED FOR OCCUPANCY UNTIL A SEPARATE TENANT TI PERMIT HAS BEEN COMPLETED. AN ADA COMPLIANT BATHROOM SHALL BE REQUIRED UNDER THE SEPARATE TENANT TI PERMIT. ELECTRICAL, MECHANICAL, PLUMBING & FIRE PERMITS TO. BE SEPARATE SUBMITTAL. APPLICABLE Building Code Fire Code Energy Code Mechanical Code Electrical Code Plumbing Code Zoning Code Accessibility Code Legal Description: EDITIONS OF BUILDING CODES: 2009 INTERNATIONAL BLDG CODE (IBC), WAC 51-50 2009 INTERNATIONAL FIRE CODE (IFC), INCL. APPENDIX B&C 2009 WASHINGTON STATE ENERGY CODE (WSEC), WAC 51-11 2009 INTERNATIONAL MECHANICAL CODE (IMC), WAC 51-52 JUNE 22, 2009 WA CITIES ELECTRICAL CODE, PARTS 1 & 3 AS PUBLISHED BY WA ASSOC. OF BLDG OFFICIALS 2009 UNIFORM PLUMBING CODE (UPC), WAC 51-56 Sc 51-57 INCL. APPENDIX CHAPTERS H & L — EXCL. SECTIONS L5—L7 & "LAWN SPRINKLER HEAD" FROM TABLE 6-4 OF APPENDIX L CITY OF TUKWILA ZONING CODE 2003 ACCESSIBLE & USABLE BUILDINGS & FACILITIES (ICC/ANSI A117.1) WAC 51-50-005 TAX PARCEL #: 2623049070 POR OF NE 1/4 OF SW 1/4 LY W OF CO RD DAF—BEG ON W LN OF SUBD 510 FT N OF SW COR TH N ALG W LN 255 FT TH E PLW S LN TO W LN OF CO RD TH S ALG SD W LN 255 FT M/L TO NXN WITH LN RNNG E FRM BEG PLW S LN OF SUBD TH W ALG SD PLL LN TO BEG LESS ST HWY LESS E 6 FT FOR ST Vicinity Map: PROJECT LOCATION Project Team: Property Manager: PINNACLE COMMERCIAL 632 ANDOVER PARK WEST SUITE 107 TUKWILA, WA 98188 (206) 575-3080 Shannon N. Miller Smiller©pinnaclefamily.com REVIEWED FOR CODE COMPLIINCE APPROVED APR 0 3 2013 City of Tukwila BUILDING DIVISION CORRECITION t_1 # Architect: JPC ARCHITECTS, PLLC 909 112TH AVE NE SUITE 206 BELLEVUE, WA 98004 (425) 641-9200 MARK PETERSON markp©jpcarchitects.com ROBERTO BUENO robe rtob®jpcarchitects.com General Contractor: DP INC. 19909 BALLINGER WAY NE SEATTLE, WA 98155 (206) 361-2989 HOLLAND HILL 1 RECEIVED CITY OF TUKWILA MAR 2 s 2013 PERMIT CENTER Good Feet Center Place Floor 1 17066 Southcenter Pkwy Suite 17045 & 17055 Tukwila, WA 98188 DESIGN DRAWN CHECKED NO. JPC RB MP 13-0195 03.01.2013 Permit Drawings A 03.25.2013 Permit Revisions Cover Sheet & Site Plan 1-0.0 © 2013, JPC Architects, PLLC Author: JAMIE HERRING Date/Time: 3/2/2013 3:46 PM Good Feet Center Place Floor 1 17066 Southcenter Pkwy Suite 17045 & 17055 Tukwila, WA 98188 DESIGN JPC DRAWN RB CHECKED MP NO. 13-0195 03.01.2013 Permit Drawings 03.25.2013 Permit Revisions General Notes & Symbols 1-0.1 © 2013, JPC Architects, PLLC Abbreviations: General Notes: A/C ACT AFF ALT. APPROX. BD BLDG BU( BLKG BOT B/S BU CAB CLG CLR COL CONC CONS CONT CORK CPT CT CTR DEMO DTL DF DIA DIM owDN c DRW E EA EL ELEC ELEV EQ EQUIP EST EXIST EXP FEC FF FH FIN FLR FLUOR FOIC FOS FOC Fr FUR GA GC GL GWB HC HCPD HDR HDWR HM HORIZ HT HVAC INSUL JAN JT KIT LAM LAV LH MAX MECH MTL MEZ MFR MIN M MTDTD MUL N NIC NTS OA OC OD OH OPNG P -LAM PNL PR PTN RAD RB RT REF REFR REINF REQ REV RH RM RO S SC SEAL SECT SHT SIM SPEC SQ SS STL STOR STRUC SUSP TEL TEMP TFTI THK THRESH TV TYP UNFIN UNO VCT VEN VERT VESTI VFY VWC WW / WD W/0 WT AIR CONDITIONING ACOUSTICAL CEILING TILE ABOVE FINISH FLOOR ALTERNATE APPROXIMATE BOARD BUILDING BLOCK BLOCKING BOTTOM BUILDING STANDARD BUILT UP CABINET CEILING CLEARANCE) COLUMN CONCRETE CONSTRUCTION CONTINUOUSDOUBT CORRIDOR CARPET CERAMIC TILE CENTER DEMOLITION DETAIL DRINKING FOUNTAIN DIAMETER DIMENSION DOWN DRAWING DRAWER EAST EACH ELEVATION ELECTRICAL ELEVATOR EQUAL EQUIPMENT ESTIMATE EXISTING EXPANSION FIRE EXTINGUISHER CABINET FACTORY FINISH FULL HEIGHT FINISH(ED) FLOOR FLUORESCENT FURNISH BY OWNER, INSTALL BY CONTRACTOR FACE OF STUD(S) FACE OF CONCRETE FOCEOT OFE FINISH FOOT/FEET GAUGE GENERAL CONTRACTOR GLASS/GLAZING GYPSUM WALL BOARD HOLLOW CORE HANDICAPPED HEADER HARDWARE HOLLOW METAL HORIZONTAL HOUR T HEATING VENTILATING AIR CONDITIONING INSULATION JANITOR JOINT KITCHEN LAMINATED) LAVATORY LEFT HAND MAXIMUM MECHANICAL METAL MEZZANINE MANUFACTURE(R) MINIMUM MISCELLANEOUS MOUNTED MULLION NORTH NOT SCALEALECONTR NOT TO S OVERALL ON CENTER OUTSIDE DIAMETER OPPOSITE HAND OPENING PLASTIC LAMINATE PANEL PA PARIR TITION RADIUS RESILIENT BASE RESILIENT TILE REFERENCE REFRIGERATOR REINFORCING REQUIRED REVISION RIGHT HAND ROOM ROUGH OPENING SOUTH SOLID CORE SEALANT SECTION SHEET SIMILAR SPECIFICATION SQUARE STAINLESS STEEL STEEL STORAGE STRUCTURAL SUSPENDED TELEPHONE TEMPERED TENANT FURNISHED & TENANT INSTALLED THICK(NESS) THRESHOLD TELEVISION TYPICAL UNFINISHED UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VENEER VERTICAL VESTIBULE VERIFY VINYL WALL COVERING /WIDE WITH WOOD WITHOUT WEIGHT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21 22. 23. 24. REFER TO BASIC BUILDING SPECIFICATIONS, REQUIREMENTS AND STANDARDS FOR EXISTING SHELL AND CORE CONSTRUCTION. ALL WORK IS TO BE COMPATIBLE WITH EXISTING CONSTRUCTION. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL REQUIRED NOTIFICATION OF AND COORDINATION WITH CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL TESTS AND INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE CONTRACTOR. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, EQUIPMENT AND TRANSPORTATION NECESSARY OR REASONABLY INFERABLE AS BEING NECESSARY FOR THE EXECUTION OF THE WORK. BY SUBMITTING A PROPOSAL, THE CONTRACTOR REPRESENTS THAT THOROUGH EXAMINATION OF THE SITE AND ALL EXISTING CONDITIONS AND LIMITATIONS HAVE BEEN MADE AND THAT THE CONTRACT DOCUMENTS HAVE BEEN EXAMINED IN COMPLETE DETAIL, AND THAT IT IS DETERMINED BEYOND THAT THE DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS ARE SUFFICIENT, ADEQUATE AND SATISFACTORY FOR CONSTRUCTION OF THE WORK. WHERE MINOR ADJUSTMENTS TO THE WORK ARE NECESSARY FOR THE PURPOSES OF FABRICATION AND INSTALLATION OF ITEMS, OR RESOLUTIONS OF CONFLICTS BETWEEN ITEMS, WITHIN THE INTENT OF THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS AT NO ADDED EXPENSE TO THE OWNER. WHERE SUCH MINOR ADJUSTMENTS AFFECT FUNCTIONAL OR AESTHETIC DESIGN OF THE WORK, THEY SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. THE CONTRACTOR SHALL COORDINATE ALL OPERATIONS WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, AND ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES. NOISY OR DISRUPTIVE WORK SHALL BE SCHEDULED AT LEAST ONE (1) WEEK IN ADVANCE OF THE TIME WORK IS TO COMMENCE. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. CONTRACTOR SHALL ADHERE TO ALL BUILDING STANDARDS. ANY CHANGES TO SAME SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR APPROVAL. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISHES OF SUCH SIZE AND NUMBER THAT THEY REPRESENT A REASONABLE DISTRIBUTION OF COLOR RANGES AND PATTERN PRIOR TO INSTALLATION FOR ARCHITECT'S APPROVAL. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND PRODUCT DATA FOR ARCHITECT'S APPROVAL ON ALL SPECIAL ITEMS REQUIRING CUSTOM FABRICATION. (SHALL INCLUDE RATED FIRE DOORS AND HARDWARE). . CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. CONTRACTOR IS NOT TO SCALE OFF DRAWINGS. CONTRACTOR SHALL PROVIDE 18 -GAUGE SHEET METAL BACKING IN PARTITIONS FOR ALL WALL-MOUNTED FIXTURES AND DEVICES UNLESS INDICATED OTHERWISE ON THE DRAWINGS. ALL FLOORS SHOULD BE LEVEL AND NOT VARY MORE THAN 1 4" IN 10'-0". THE / CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY CONDITIONS THAT DO NOT MEET THIS STANDARD. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, SHAPE, COLOR, TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE ARCHITECT BEFORE USE. ALL FIREPROOFING DISTURBED DURING CONSTRUCTION SHALL BE REPLACED TO MATCH ORIGINAL FIRE PROTECTION LEVELS. (OBTAIN REQUIRED APPROVALS AND TESTING). THE FLOORS MAY BE OCCUPIED DURING CONSTRUCTION. THE CONTRACTOR SHALL ALL PERSONNEL, PASSERSBY OR VISITORS TO THE SITE FROM HARM AND INJURY. INJURY. BARRIERS SHALL BE INSTALLED AS REQUIRED TO PROTECT EQUIPMENT INSTALLED DURING CONSTRUCTION. CAREFULLY MAINTAIN AND PROTECT MONUMENTS, BENCH MARKS AND THEIR REFERENCE POINT FROM BEING DESTROYED OR DISTURBED; REPLACE AS REQUIRED. EXISTING WORK DAMAGED AS A RESULT OF WORK DONE UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO ARCHITECT'S APPROVAL, AND AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIALS REQUIRED. TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY THE ARCHITECT AND OWNER PRIOR TO INSTALLATION. ' ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICES DISRUPTED OR REMOVED DURING CONSTRUCTION SHALL BE RESTORED AND REPLACED UNLESS NOTED OTHERWISE. FIRE/LIFE SAFETY SYSTEMS TO BE MAINTAINED DURING CONSTRUCTION. INSTALLATION OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE NOTED OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS, FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED. OPENINGS REQUIRED FOR NEW WORK THAT PENETRATES EXISTING STRUCTURE SHALL BE COORDINATED WITH OWNER PRIOR TO COMMENCING THE WORK. ANY OPENING OVER 2" IN DIAMETER SHALL BE REVIEWED AND APPROVED BY OWNER. THROUGH CONCRETE SLABS OR WALLS, OR MASONRY WALLS, ALL ROUND HOLES SHALL BE CORE DRILLED WITH A DIAMOND DRILL AND ALL RECTANGULAR OPENINGS SHALL BE CUT WITH A DIAMOND SAW. IN NO CASE SHALL ANY STRUCTURAL MEMBER BE CUT. USEb CARBIDE -TIPPED DRILLS FOR GYPSUM WALLBOARD PARTITIONS. KEEP OVERCUTTING TO A MINIMUM. MAINTAIN CONTINUITY AND INTEGRITY OF FIRE SEPARATION AT ALL TIMES. GROUT AROUND CONDUITS PASSING THROUGH CONCRETE WALLS AND FLOORS AND MASONRY WALLS. MAKE PATCHES WITH NEAT, TRIMMED EDGES; MATCH ADJACENT EXISTING WORK. " " "'"' ' ' " CONTRACTOR SHALL PROVIDE FLOOR LEVELING AS MAY BE REQUIRED AT SLIDING DOORS, RELITES WITHOUT BASE, CABINET WORK, AND OTHER LOCATIONS REQUIRING LEVEL SUBSTRATE. FEATHER CHANGES IN ELEVATION OVER SUFFICIENT AREA TO LIMIT TRANSITION SLOPE TO 1/8" PER FOOT. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING ACCEPTABLE MANUFACTURERS OR PRODUCTS, BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS, OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY NAME, SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY REFERENCE STANDARDS OR BY PERFORMANCE SPECIFICATIONS SELECT ANY PRODUCT MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED, SUBMIT REQUIRED SUBMITTALS, PROVIDING COMPLETE BACK-UP INFORMATION FOR PURPOSES OF EVALUATION. WHERE BUILDING STANDARD ITEMS ARE CALLED FOR, NO SUBSTITUTE WILL BE ACCEPTED. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH LOCAL FIRE CODE. PROVIDE FOR ALL REQUIRED SHOP DRAWINGS AND APPROVALS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING FIRE ALARM SYSTEM AUDIBILITY. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED, SPACKLED WITH NO VISIBLE JOINTS. PATCH AND REPAIR SURFACES ADJOINING SURFACES WHERE REQUIRED. ALL SURFACES MODIFY EXISTING SUBSTRATE AS REQUIRED TO RECEIVE PREVENTING NOTICEABLE LUMPS OR DEPRESSIONS. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, REFER TO MILLWORK SHOP DRAWINGS FOR SPECIFIC DRYWALL/MILLWORK CONDITIONS. ALL GLASS SHALL BE CLEAR TEMPERED GLASS, UNLESS TONG MARKS SHALL NOT BE VISIBLE. CLEAN AND POLISH PROJECT DELIVERY. ALL MILLWORK TO BE FASTENED TO THE PARTITION. PROVIDE BLOCKING FOR ALL MILLWORK NOT SUPPORTED BY FLOOR CONCEALED LUMBER & BLOCKING TO BE FIRE TREATED. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR: HVAC, CASEWORK. CLEAN, REPAIR ANY EXISTING PERIMETER BLINDS AS FUNCTIONING & OPERATIONAL MANNER. COORDINATE WITH SUB -CONTRACTORS THE LOCATIONS OUTLETS,ASPLUMBING AND OTHER DEVICES WITH LAYOUT CASEWORK. CASEWORK SHALL CONFORM TO A.W.I. CURRENT STANDARDS. ‘34%-o AND SANDED SMOOTH TO MATCH ADJACENT OR SHALL BE ALIGNED, NEW FLOORING MATERIALS, LEVEL, SQUARE AND TRUE. DETAILS OF COORDINATION BETWEEN OTHERWISE NOTED. GLAZING ALL GLASS PRIOR TO NON-COMBUSTIBLE OR ABOVE 4'-0" HT. ALL CARPET SEAMING, LIGHTING, REQUIRED TO BE IN.A FULLY OF ELECTRICAL AND VOICE/DATA AND DESIGN OF CUSTOM gal 1 THUS REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 2 2013 PERMIT CENTER ON THE ARCHITECTURAL DRAWINGS,FINIMECHANICAL AND ELECTRICAL XTURESFOR LOCATION INFORMATION ONLY. , OUTLETS, ETC., WHENSHOW N MECHANICAL AND Symbol Legend: ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION TO BE BY OTHERS. CONTRACTOR IS TO PROVIDE DRAWINGS FOR ARCHITECT'S APPROVAL SHOWING LOCATIONS OF ALL HVAC THERMOSTATS, GRILLES AND DIFFUSERS, FIRE AND SMOKE DETECTION DEVICES INCLUDING SPRINKLERS, SMOKE DETECTORS, FIRE EXTINGUISHERS AND HOSE CABINETS, PLUMBING AND PLUMBING EQUIPMENT. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL OR STRUCTURAL COMPONENTS MUST BE APPROVED BY THE ARCHITECT. ALL PERMITS INCLUDING FIRE, MECHANICAL, AND ELECTRICAL TO BE FILED SEPARATELY. DETAIL REFERENCE BUBBLE JOB NORTH REFERENCE KEY (REFER TO SHEET/KEY NOTES) 2306 ROOM NUMBER REFERENCE 1-10.3 DOOR NUMBER REFERENCE. A REVISION REFERENCE a 1-10.3 INTERIOR ELEVATION SYMBOL © Good Feet Center Place Floor 1 17066 Southcenter Pkwy Suite 17045 & 17055 Tukwila, WA 98188 DESIGN JPC DRAWN RB CHECKED MP NO. 13-0195 03.01.2013 Permit Drawings 03.25.2013 Permit Revisions General Notes & Symbols 1-0.1 © 2013, JPC Architects, PLLC "COMMON PATH OF EGRESS TRAVEL" IS LESS THAN 75'-0" PER 2009 IBC 1014.3. x U z Author: JAMIE HERRING Pen Table: JPC M 0 s E 4 MKS trIMPAISIM 1121 Ell El IE El El El = 8011 MO MI El El 1101 OE El El = El BE OE 1 1 IMESSAVEN 7 l 1 1 0 0 a Os I 1 1 IIi � 4d'iil /011hlOk iminommorimee 1,453 SF OCC: 1/30 0 48 e OT El Ea El - - Eli 1 1 11 1 11 1 1 1 1 1 11 1 • 0 1 1 1,347 SF OCC: 1/30 45 FORTERSIMMILMSIVIVIVANW "n" 1 1 SCOPE OF WORK Exit Plan Scale: 1/8"=1'-0" I ZVMRMPMVAVELTVEMXMVBBXVBIWXMIIVIIITIMVSIVCMIOS D13-0--/ 1 REVIEWED FOR CODE COMPLI p,,NCE APPROVED APR 0 3 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 2 6 2013 PERMIT CENTER C) N CD w N c w N cT o• Good Feet Center Place Floor 1 17066 Southcenter Pkwy Suite 17045 & 17055 Tukwila, WA 98188 Legend: "TOTAL EXIT ACCESS TRAVEL DISTANCE" IS LESS THAN 250'-0" (200'-0" FOR NO QUICK RESPONSE OR NON SPRINKLERED) AS ALLOWED FOR SPRINKLERED BUILDINGS WITH QUICK RESPONSE HEADS. r3 DENOTES NUMBER OF OCCUPANTS DESIGN DRAWN CHECKED NO. JPC RB MP 13-0195 03.01.2013 Permit Drawings A 03.25.2013 Permit Revisions Exit Plan and Codes Summary I-cs © 2013, JPC Architects, PLLC O WHERE PRACTICAL, TENANT IMPROVEMENT WALLS HAVE BEEN ALIGNED WITH OR CENTERED ON WINDOW MULLIONS, PILASTERS AND/OR STRUCTURAL COLUMNS. WALLS HAVE BEEN DIMENSIONED FOR ADDITIONAL CLARITY WHEN OR WHERE EVER NECESSARY. O AT LOCATIONS AS NECESSITATED BY "IN -WALL" ELECTRICAL AND/OR MECHANICAL SYSTEMS PROVIDE APPROPRIATE METAL STUD WIDTH TO ACCOMMODATE SIZING REQUIREMENT. CONFORM TO SPECIFIED METAL GAUGE AND SPACING AS INDICATED BY WALL TYPE. REFER TO CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. O ONE (1) 120/208 VOLT 3-PHASE, 4 -WIRE 100 AMP MAIN DISTRIBUTION PANEL WITH A DISCONNECT SWITCH TO ONE (1) 120/208 VOLT 3-PHASE, 4 -WIRE 100 AMP MAIN LIGHTING DISTRIBUTION PANEL WITH SEPARATE ELECTRICAL SERVICE AND METER. SERVICE TO BE UNDERGROUND WHEREVER POSSIBLE. REFER TO ELECTRICAL DESIGN -BUILD DOCUMENTS FOR ADDITIONAL INFORMATION. ONE (1) DEDICATED CIRCUIT WITH A TIME CLOCK TO THE STORE FRONT OF BUILDING FOR TENANTS SIGN. REFER TO ELECTRICAL DESIGN -BUILD DOCUMENTS FOR ADDITIONAL INFORMATION. ONE (1) 120 VOLT OUTLET AT INSIDE FACE OF STOREFRONT FOR TENANT FURNISHED/INSTALLED SIGNAGE. REFER TO ELECTRICAL DESIGN -BUILD DOCUMENTS FOR ADDITIONAL INFORMATION. ONE (1) 120 VOLT DUPLEX (GFI) OUTLET. REFER TO ELECTRICAL DESIGN -BUILD DOCUMENTS FOR ADDITIONAL INFORMATION. 120 VOLT DUPLEX OUTLETS AT 20'-0" 0/C. COORDINATE FINAL PLACEMENT WITH GOOD FEET AND/OR GOOD FEETS ARCHITECT PRIOR TO COMMENSIING WORK. REFER TO ELECTRICAL DESIGN -BUILD DOCUMENTS FOR ADDITIONAL INFORMATION. PROVIDE ONE (1) EMPTY 3/4" PHONE CONDUIT TO THE DEMARCATION PANEL. ALLOW VOLTAGE CABLE TO BE PULLED INTO SPACE BY TENANT. PHONE JACKS TO BE FURNISHED AND INSTALLED BY TENANT. e 11 PROVIDE AND INSTALL 3'-0" x 7'-0" SOLID CORE DOOR (PAINT GRADE) AND FRAME WITH PRIVACY LOCKING HARDWARE AND CLOSER. REFER TO DOOR TYPE C - SHEET 1-10.1 13 • 11— L R A 1 ABOVE FINISH FLOOR (A.F.F.). PROVIDE IDENTIFICATION SIGNAGE AT EACH EXTINGUISHER LOCATION AS REQUIRED. PROVIDE IDENTIFICATION SIGNAGE AT EACH EXTINGUISHER LOCATION AS REQUIRED. CONFORM TO BUILDING STANDARD FOR MANUFACTURER (CABINET/BOTTLE) TYPE AND STYLE. PROVIDE AND INSTALL SAFETY GLAZING AS REQUIRED BY SECTION 2403 OF THE 2009 INTERNATIONAL BUILDING CODE (I.B.C.). GLAZING SHALL COMPLY WITH IDENTIFICATION, SUPPORT, FRAMING AND DEFLECTION. GLAZING SYSTEMS THAT DO NOT MEET THE REQUIRED CRITERIA SHALL BE THICKENED VS DOWNSIZED IN ORDER TO MEET OR EXCEED SAID A I 1 at Floor Plan Scale: 1/8"=1'-0" Partition Legend: Good Feet Center Place Floor 1 17066 Southcenter Pkwy Suite 17045 & 17055 Tukwila, WA 98188 EXISTING PARTITION TO BE REMOVED EXISTING PARTITION/CONSTRUCTION TO REMAIN EXISTING SHELL & CORE WALLS FULL HEIGHT PARTITION. REFER TO DETAIL 4/1-10.1. Symbols Legend: R. PROVIDE CONCRETE LEVELING AT REAR DOORWAY. CONFORM TO CURRENT ANSI REQUIREMENTS AND CITY OF TUKWILA CODES FOR SLOPE REQUIREMENTS. PROVIDE AND INSTALL 3'-0" X 7'-0" INSULATED HOLLOW METAL DOOR AND FRAME WITH LOCKET/LOCK PROTECTOR, CLOSER, WEATHER STIPPING AND THRESHOLD. INSTALLATION OF DOOR (INCLUDING FRAMING AND HEADER), FLASHING AND TRIMS TO MATCH EXISTING BUILDING STANDARD. REFER TO DOOR TYPE A - SHEET 1-10.1 PROVIDE AND INSTALL 3'-0' ALUMINUM STOREFRONT DOOR WITH LOCKING HARDWARE AND SIDELIGHT. DOOR AND SIDELIGHT TO MATCH EXISTING BUILDING STANDARD FOR TYPE, STYLE AND INSTALLATION TECHNIQUES, INCLUDING BUT NOT LIMITED TO INSULATED GLAZING COLOR, SPANDREL PANEL COLOR, CLOSERS AND THRESHOLD. REFER TO DOOR TYPE B - SHEET 1-10.1 IE MCCIAMMitx 1 1 1 1 1 1 1 1 1 11 1 1 1 n 11 u ILSOMMOVitMAGMWMPAiert 1 1 gin en ana ® en ® en ® on gm ran no en en nn En en en se na an mn en en on an me en en cm zaP SCOPE OF WORK IMIEMISSM mismorm Demolition Plan Scale: 1/8"=r-0" P 1 I MUMMMWMINNWAIMMEMMUMWWW 12J BATTERIES PLUS 1 1 1 1 1 1 1 11 11 11 1 11 1 1 1 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 no NNORMMUM SUITE 17055 GOOD FEET SUITE 17045 FUTURE RETAIL THIS SPACE NOT APPROVED FOR OCCUPANCY UNTIL A SEPARATE TENANT TI PERMIT HAS BEEN COMPLETED. AN ADA COMPLIANT BATHROOM SHALL BE REQUIRED UNDER THE SEPARATE TENANT TI PERMIT. 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® SUITE 17065 e n cm on En en ms no nn um en en me SCOPE OF WORK Demolition Plan Key Notes: Floor Plan Key Notes: ROLL -UP, BAG AND PROTECT EXISTING EXTERIOR HORIZONTAL MINI -BLINDS. REPAIR AND/OR PROVIDE NEW WHERE FOUND MISSING OR DAMAGED. REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION. O GENERAL CONTRACTOR TO COORDINATE WITH LANDLORD REMOVAL, SALVAGE AND/OR DISPOSAL OF EXISTING F.F. & E. ITEMS WITHIN THE EXISTING SUITE. DEMOLISH EXISTING FINISH FLOORING AND BASE MATERIALS. PATCH AND REPAIR AFFECTED SUBSTRATE AS REQUIRED FOR INSTALLATION OF NEW FINISH FLOORING AND BASE MATERIALS. COORDINATE WITH GOOD FEET AND/OR GOOD FEETS ARCHITECT AS REQUIRED. REMOVE EXISTING WALL COVERING MATERIALS FROM REMAINING PARTITION WALLS (IF PRESENT). PATCH AND REPAIR AFFECTED G.W.B. SUBSTRATE AS REQUIRED FOR FINISH TREATMENT. COORDINATE WITH GOOD FEET AND/OR GOOD FEETS ARCHITECT AS REQUIRED. REMOVE AND SALVAGE ALL EXISTING WHITEBOARDS, TACKBOARDS, DISPLAY AND SIGNAGE SYSTEMS (IF PRESENT). PATCH AND REPAIR AFFECTED AREAS AS REQUIRED FOR FINISH TREATMENT. COORDINATE WITH GOOD FEET AND/OR GOOD FEETS ARCHITECT AS REQUIRED. PROVIDE SELECTIVE DEMOLITION AT EXISTING FRAME WALL AS REQUIRED TO INSTALL NEW BUILDING STANDARD HOLLOW METAL DOOR AND FRAME. PROVIDE SELECTIVE DEMOLITION AT EXISTING STOREFRONT AS REQUIRED TO INSTALL NEW BUILDING STANDARD STOREFRONT DOOR, FRAME AND SIDELIGHT. REMOVE AND SALVAGE FIRE EXTINGUISHERS, CABINETS, MARINE BRACKETS AND SIGNAGE FOR REUSE AND REINSTALLATION. REFER TO FLOOR PLAN FOR ADDITIONAL INFORMATION. F.E.C. =@ DUPLEX RECEPTACLE = DEDICATED DUPLEX RECEPTACLE DUPLEX RECEPTACLE AT FLOOR FOURPLEX RECEPTACLE ELECTRICAL PANEL r • VOICE/DATA RECEPTACLE. CONTRACTOR TO PROVIDE MUD RING AND PULL STRING -. WALL TAG NO DESIGNATION OR E = EXISTING N = NEW &/OR RELOCATED (COORDINATE RELOCATED ITEMS W/ARCHITECT) D = DEMOLISH b_13..%•0 7 I REVIEWED FOR CODE COMPLIANCE APPROVEb APR 0 3 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 2 6 2013 PERMIT CENTER DESIGN DRAWN CHECKED NO. JPC RB MP 13-0195 03.01.2013 Permit Drawings 03.25.2013 Permit Revisions Demolition & Floor Plan 1-3.1 © 2013, JPC Architects, PLLC Author: JAMIE HERRING Table: JPC STD.CTB 3/25/2013 10:37 AM 0 IIM ▪ MI 1M MI MS 111 MN ME BM CM Ell MII 1M MI 1111 0111 1111 OM IN 110 EM 111% 1 fftl 444,4ilatiiik4 41v 1 1 11 1 1 111 11 1 1 1 1 11 1 1 11 1 11 1 1 1 1 1 1 11 1 11 1 1 1 1 1 1 • • • • E -tel l _ J • • • l _ J L J I% 1 • • • r-� TYP r�71 L _ J L.71177 � _ • J • • • • Il 1 r�� •D • • D. TYP • • • _ J _ J It_ • D D • • r�T IL_ J TY • TYP • • • mamma -8— — —p— 1 1 11 1 11 1 11 11 11 1 1 1 11 1 1 1 11 1 1 1 1 1 1 1 1 1 11 1 11 1 1 1 1 1 1 1 1 1 ®®®®®®®®®® CM ®®®®®I® II® Ems ®®®ll®®®NE mu 1E9 anhaitikkelf SCOPE OF WORK Demo Reflected Ceiling Plan Scale: 1/8"=1'-0" Demolition RCP Key Notes: SOLID LINE INDICATES EXTENT OF EXISTING SUSPENDED CEILING GRID, ACOUSTICAL TILE AND ASSOCIATED SUPPORT/RESTRAINT SYSTEMS TO BE DISASSEMBLED AND/OR DEMOLISHED IN ORDER TO PREPARE FOR INSTALLATION OF NEW FULL HEIGHT DEMISING WALL(S). REFER TO REFLECTED CEILING PLAN AND DESIGN—BUILD CONSULTANT DOCUMENTS FOR ADDITIONAL INFORMATION. EXISTING BUILDING STANDARD HEAVY DUTY SUSPENDED CEILING GRID AND ACOUSTICAL TILE SYSTEM. REFER TO REFLECTED CEILING PLAN FOR ADDITIONAL INFORMATION. REMOVE, RELOCATE AND REINSTALL EXISTING LIGHTING. REFER TO SYMBOLS LEGEND, REFLECTED CEILING PLAN AND DESIGN—BUILD ELECTRICAL DOCUMENTS FOR ADDITIONAL INFORMATION. DEMOLISH AND DISPOSE OF EXISTING RECESSED CAN AND TRACK LIGHTING SYSTEMS. mamwevoz 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address 17065 Southcenter PKWY Date 3/24/2013 Tukwila, WA For Building Department Use 98188 Applicant Name: JPC Architects Applicant Address: 909 112th Ave r18, Suite 206, Bellevue, NA 98004 Applicant Phone: 425.641.9200 Project Description ❑ New Building 0 Addition I] Alteration I] Plans Included Indicate controls (Sections 1513) Including commissioning requirements on plans. Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0SystemsAnalysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) I ❑ No changes are being made to the lighting and space use not changed L] Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan!room #) Occupancy Description Allowed Watts per ft2 " Gross 101800r Area in ft2 Allowed x Area From Table 15-1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watts Location (floor plan/room #) Fixture Description Number of Fixtures Watts! Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps In the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) In addition to the fixture, lamp, and ballast Information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum Input wattage of the fixture (not simply the lamp wattage) and other criteria as specified In Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. pIMI IINN ®®® Mil ® ® ▪ 110 i▪ ®IM i®®®®i®®®®® E N N IP N • • TY P 0 • • • 1 ©TYP • 07) • 1 V • • • • TY P 1 1 1 1 1 11 11 1 11 11 11 1 1 1 1 1 1 1 11 1 1 •R • • I% I •R 1F1 • P • • • • • • • • • YF' • lin® = = = mo ® ® cm = = = = ®®®= = = cm ® ® ® = - = ® ®' SCOPE OF WORK A. Reflected Ceiling Plan Scale: 1 /8"=1'-0" O N CD •t_+ W z N c tU s N CJs Good Feet Center Place Floor 1 17066 Southcenter Pkwy Suite 17045 & 17055 Tukwila, WA 98188 Reflected Ceiling Plan Key Notes: O EXISTING BUILDING STANDARD HEAVY DUTY SUSPENDED CEILING GRID AND ACOUSTICAL TILE SYSTEM. REPLACE ALL BENT/SCRATCH OR OTHERWISE DAMAGED CEILING GRID AND DAMAGED AND/OR STAINED TILE WITHIN SCOPE OF NEW WORK. ASSUME 35% NEW CEILING TILE OVER SCOPE OF WORK, NOT INCLUDING LIGHT, HVAC, SPRINKLER HEAD REMOVAL/RELOCATION AND TILE CUTS ASSOCIATED TO NEW DEMISING WALL/SEISMIC JOINTS. O LIGHTING FIXTURES (EXISTING AND/OR EXISTING RELOCATED). REFER TO SYMBOLS LEGEND AND ELECTRICAL DESIGN—BUILD DOCUMENTS FOR ADDITIONAL INFORMATION. O PROVIDE SURFACE MOUNTED LIGHT ABOVE SINK COUNTER WITH SWITCH. COORDINATE SPECIFICATION WITH GOOD FEET AND/OR GOOD FEETS ARCHITECT AS REQUIRED. ® EGRESS LIGHTING (BATTERY BACKED) SHALL BE DESIGNED BY A LICENSED ELECTRICAL ENGINEER BASED ON FINAL FLOOR PLAN(S) AND THE MOST CURRENT (IN FORCE) ISSUE OF THE IBC, IEC AND LOCAL CODES/ORDINANCES. THE ENGINEER MAY USE THE ARCHITECTS EXIT DIAGRAM AS STARTING POINT FOR A BASIS OF DESIGN. HOWEVER, IT SHALL REMAIN THE SOLE RESPONSIBILITY OF THE ENGINEER TO COMPLETE A SCOPE OF WORK THAT ADDRESSES ALL EGRESS LIGHTING I.E.; ROOMS, SPECIAL SPACES, PATHWAYS, ETC. PER THE AFOREMENTIONED CODES. FINAL EGRESS LIGHTING QUANTITIES AND LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE INSPECTOR'S FIELD PLACEMENT DETERMINATION. ® PROVIDE AND INSTALL (BATTERY BACKED) EXIT LIGHTING AS INDICATED. FINAL EGRESS SIGNAGE QUANTITIES AND LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE INSPECTOR'S FIELD PLACEMENT DETERMINATION. ® (1) LIGHT MINIUMUM SHALL BE WIRED AS A 24/7 NIGHT LIGHT AND (1) LIGHT MINIMUM SHALL BE BACKED UP FOR EMERGENCY LIGHTING PURPOSES. REFER TO KEY NOTES 6, 7 AND ELECTRICAL DESIGN—BUILD DOCUMENTS FOR ADDITIONAL INFORMATION. O7 PROVIDE RECESSED CEILING FAN (VENTED TO THE EXTERIOR) WITH SWITCH. REFER TO MECHANICAL DESIGN—BUILD DOCUMENTS FOR ADDITIONAL INFORMATION. ® PROVIDE 6 GALLON HOT WATER TANK WITH PAN ABOVE CEILING. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN, FABRICATION AND INSTALLATION OF TANK SUPPORT SYSTEM. REFER TO MECHANICAL DESIGN—BUILD DOCUMENTS FOR ADDITIONAL INFORMATION. 10 11 12 CONTRACTOR TO VERIFY CODE COMPLIANCE OF ALL EXISTING ACOUTICAL CEILING GRID SYSTEMS AND ASSOCIATED SEISMIC BRACING RESTRAINTS. SYSTEMS FOUND NOT IN COMPLIANCE SHALL BE MODIFIED AND/OR NEW PROVIDED AS REQUIRED TO MEET OR EXCEED CURRENT BUILDING CODES. CONTRACTOR TO VERIFY CODE COMPLIANCE OF ALL LIGHTING FIXTURES AND ASSOCIATED SEISMIC BRACING RESTRAINTS. SYSTEMS FOUND NOT IN COMPLIANCE SHALL BE MODIFIED AND/OR NEW PROVIDED AS REQUIRED TO MEET OR EXCEED CURRENT BUILDING CODES. PROVIDE AND INSTALL HVAC PER GOOD FEET SPECIFICATION AS FOLLOWS: • SUITE SHALL BE A MINIMUM OF ONE (1) TON PER 400 SF CONTAINED IN DEMISED PREMISES, FULLY FUNCTIONAL AND CAPABLE OF MAINTAINING 78 DEGREES FAHRENHEIT IN COOLING MODE (SUMMER) AND 72 DEGREES FAHRENHEIT IN HEATING MODE (WINTER). • DESIGN CRITERIA FOR MECHANICAL SYSTEM TO INCLUDE GLASS AREA EXPOSURE, CUSTOMER AND EMPLOYEE LOAD, AND PROVIDED LIGHTING LOAD. •AIR CONDITIONING AND HEATING UNITS TO BE EQUIPPED WITH AUTOMATIC SET BACK THERMOSTATS — ONE (1) PER UNIT. • DUCT WORK AND ONE (1) SUPPLY DIFFUSER PER 250 SF CONTAINED IN THE DEMISE PREMISES. •T—STAT LOCATION TO BE REVIEW AND APPROVED BY GOOD FEET AND/OR GOOD FEETS ARCHITECT. •ANY ASSOCIATED STRUCTURAL WORK REQUIRED BY THE HVAC INSTALLATION SHALL BE THE RESPONSIBILTY OF THE GENERAL CONTRACTOR AND/OR DESIGN—BUILD MECHANICAL CONTRACTOR. WORK SHALL BE PREFORMED BY A CERTIFED AND LICENSED STRUCTRAL ENGINEER FOR THE STATE WITHIN THE WORK IS TO BE PERMITED AND CONSTRUCTED. MODIFY LIFE SAFETY SYSTEMS AS REQUIRED BY SCOPE OF NEW WORK AND MOST CURRENT ISSUE OF APPLICABLE BUILDING CODES. Symbols Legend TYPE SYMBOL MFG. DESCRIPTION SWITCH lei BLDG STD EXIT LIGHT EXTG BLDG STD 2x4 SUSP. CEILING GRID & TILE NEW BLDG STD 2x4 CEILING TILE IN EXISTING GRID F-1 ' BLDG STD 2x4 FLU. LIGHT FIXTURE, 2—T8 WW LAMPS NO DESIGNATION OR E = EXISTING N = NEW &/OR RELOCATED (COORDINATE RELOCATED ITEMS W/ARCHITECT) D = DEMOLISH REVIEWED FOR CODE COMPLI\NCE APPROVE APR 0 3 2013 City of Tukwila BUILDING DIVISION bt3O7I RECEIVED CITY OF TUKWIL.A MAR 2 6 2013 PERMIT CENTER DESIGN DRAWN CHECKED NO. JPC RB MP 13-0195 03.01.2013 Permit Drawings A 03.25.2013 Permit Revisions DEMO RCP & Reflected Ceiling Plan 1-4.1 © 2013, JPC Architects, PLLC Author. JAMIE HERRING i Pen Table: JPC STD.CTB O 0 0 I 1111 1111111 I II I I I I I I I I II I 111111 111111 11111111111111111111111111111 III 1111111111111111111111111111111I I cimimmomMIMIEEMMiMMMIMIESIMIMIMIMIMIIMMIMMIIMI Plan - Public Restroom 101 PLAM WAINSCOT WITH METAL TRIM (PL -6 TBD) 6" SHEET VINY FLOOR COVE (SV—TBD Enlarged Plan 52" MIN. 42" MIN. Scale: 1 /4"=1 '-0" PLAM WAINSCOT WITH METAL TRIM (PL -6 TBD) 6" SHEET VINYL FLOOR COVE (SV—TBD) O op co Good Feet Center Place Floor 1 17066 Southcenter Pkwy Suite 17045 & 17055 Tukwila, WA 98188 Fixture Schedule: KOHLER K-3519 HIGHLINE, PRESSURE -LITE TOILET WITH 12" ROUGH -IN AND LEFT-HAND TRIP LEVER WITH TANK FITTINGS, 1.1 GALLONS PER FLUSH- WHITE. KOHLER - K-4650 S ELONGATED OPEN FRONT SEAT WITH COVER. AMERICAN STANDARD MURRO VITREOUS CHINA WALL HUNG LAVATORY; WHITE; WITH SHROUD/KNEE GUARD; AMERICAN STANDARD MONTERREY WIDESPREAD LAVATORY FAUCET WITH GOOSENECK SPOUT M • 1'-6" GRAB BAR: BOBRICK - B5806-18; STAINLESS STEEL • 3'-0" GRAB BAR: BOBRICK - B5806-36; STAINLESS STEEL • 3'-6" GRAB BAR: BOBRICK - B5806-42; STAINLESS STEEL ® • BOBRICK MIRROR B-29002436 24" (61 cm) X 36" (91 cm) • SEAT COVER DISPENSER: BOBRICK - B4221; STAINLESS STEEL © • TOILET TISSUE DISPENSER: BOBRICK - B2892; STAINLESS STEEL El • FEMININE NAPKIN DISPOSAL: BOBRICK - B4353; STAINLESS STEEL ® • STAINLESS STEEL SHELF BOBRICK - 24" LENGTH B-298 Ei •SOAP DISPENSER - TBD 10 • PAPER TOWEL DISPENSER BOBRICK - WALL MOUNTED B-262 11 • SURFACE MOUNTED LIGHT 3ri REVIEWED FOR CODE COMPLIANCE APPROVEb APR 0 3 2013 city of Tukwila BUIL[ ING DIVISION RECEIVED CITY OF TUKWILA MAR 2 6 2013 PEtit RMIT CENTER DESIGN JPC DRAWN RB CHECKED MP NO. 13-0195 03.01.2013 Permit Drawings \ 03.25.2013 Permit Revisions Enlarged Plan - Restroom 1-7.1 © 2013, JPC Architects, PLLC 0 CD .3 m Q Author: JAMIE HERRING Date/Time: 3/25/20 / 5 \ 1-10.1 SIM 12 1-10.1 BLDG. STD. 3'-0" X 7'-0"X 1-3/4" SC, HOLLOW METAL BACK DOOR. FINISH: MATCH EXISTING STOREFRONT BASE, AS SPECIFIED Door Type A - Hollow Metal Scale: 3/8"=1'-0" DESIGNED DEFLECTION EXISTING STRUCTURE FILL VOID WITH ACOUSTICAL SEALANT BOTH SIDES (OUTER) DEFLECTION TRACK (INNER) HEAD TRACK SECURE STUDS TO LEG OF HEAD TRACK INSULATION AS NOTED BELOW INSULATION TO EXTEND 2'-0" BEYOND EACH SIDE OF WALL AS NOTED BELOW CEILING AS SPECIFIED ONE LAYER 5/8" GWB EACH SIDE OF WALL CONT. MTL. RUNNER MECHANICALLY FASTENED TO SUBFLOOR. SPACING AND EMBED DEPTH PER GOVERNING CODE & REGULATIONS. SPECIFIED BASE ACOUSTICAL SEALANT BOTH SIDES FINISHED FLOOR 1/8" FOAM TAPE WALL TYPE WALL HT. STUD SIZE STUD THICKNESS STUD SPACING WALL THICKNESS INSULATION FIRE RATING/ UL DESIGN NO. COMMENTS WALL CEILING A FULL 3-5/8" 20 GA. 16" 0.C. 4 7/8" - - - - Demising Wall Scale: 3"=1'-0" APPROVED "FIRE EXTINGUISHER" SIGNAGE 3" HIGH WHITE HELVETICA LETTERING ON RED BACKING OF 8"x12" SIGN. PROVIDE SIGNAGE ON ALL FOUR SIDES OF COLUMN ENCLOSURE WHEN FIRE EXTINGUISHER OCCURS AT COLUMN. BUILDING STANDARD FIRE EXTINGUISHER CABINET WHEN LOCATED AT COLUMNS, CABINET AND SIGNAGE TO BE CENTERED ON COLUMN ENCLOSURE. TYPICAL, U.N.O.. *SB=SOUND ATTENUATION BATTS SCHEDULED DOOR (OPEN OR CLOSED) WALL -MTD. TELEPHONE OUTLET THERMOSTAT HARDWARE SET AS SCHEDULED ELEC. OUTLET TEL. OUTLET 0 FR=FIRE RESISTIVE 9 1-10.1 BLDG. STD. 3'-0" X 7'-0"X 1-3/4 ALUMINUM STORE FRONT DOOR FINISH: MATCH EXISTING f STOREFRONT 11 -10.1 Door Type B - Aluminum Storefront r - LIGHT WITCH DOTTED INE INDICATES 'LOCATIO OF LARGER "RLATE FOR GANGED SWITCHES 2-3/4" VERIFY W/ HARDWARE SCHEDULE NOTE : INSTALL LOCAL ELECTRICAL AND TELEPHONE WALL OUTLETS AND SWITCHPLATES AT NEAREST STUD FROM SCALED LOCATION ON PLAN UNLESS SPECIFICALLY DIMENSIONED. Typical Mounting Heights NOTE: HEIGHTS ARE AS NOTED UNLESS DIRECTED BY B/S TO BE DIFFERENT Scale: 3"=1'-0" DO NOT SECURE PARTITION TO GLAZING SYSTEM, ATTACH AT WALL ABOVE AND BELOW GLAZING BOX STUD TO CONFORM TO SITE CONDITIONS LINE OF SILL (VARIES PER SITE CONDITION) MTL. STUD ATTACHED TO VERTICAL MULLION W/ DOUBLE SIDED (STICKY) FOAM TAPE Typical Mullion/Partition Termination Scale: 3"=1'-0" Scale: 3/8"=1'-0" U ALUMINUM DOOR FRAME TO MATCH EXISTING >Fr -7( Aluminum Door Jamb (Head Similar) Scale: 6"=1'-0" ALUMINUM DOOR FRAME TO MATCH EXISTING Aluminum Door Jamb ALUMINUM DOOR TO MATCH EXISTING GLAZING TO MATCH EXISTING 1. LATERAL BRACING CLUSTER: (4) 12 GA. GALV SOFT -ANNEALED MILD STEEL WIRES SECURED TO MAIN RUNNER WITHIN 2" OF CROSS 'T' AND SPLAYED 90 DEGREES FROM EACH OTHER AT 45 DEGREES MAX. ABOVE HORIZONTAL. CLUSTERS PLACED 12'-0" 0.C. MAX. AND 6'-0" MAX. FROM EACH WALL. WIRES SHOULD BE TAUT WITHOUT CAUSIN CEILING TO LIFT. 2. SUSPENSION WIRE: 12 GA. GALV. SOFT -ANNEALED MILD STEEL WIRE ENCASED IN 1/2" DIAM. CONDUIT (FOR UPL RESTRAINT); SECURE WIRE TO MAIN RUNNER WITHIN 2" OF CROSS 'T'. CONDUIT TO OCCUR AT EVERY LATERAL BRACING CLUSTER AND SUSPENSION WIRES TO OCCUR AT 4'-0" 0.C. MAX. EACH WAY. FASTEN RUNNERS TO PERIMETER WALL ANGLE AT (2) ADJACENT SIDES PROVIDE MIN. 2" WIDE WALL ANGLE. NOTE NO. NOTE NO. 2 MAIN RUNNER, HEAVY DUTY 0 VIEW SHOWING LATERAL BRACING 411 CLUSTER AND SUSPENSION WIRE ALUMINUM DOOR FRAME TO MATCH EXISTING GLAZING TO MATCH EXISTING Scaler 6"=1'-0" GLAZING TO MATCH EXISTING ALUMINUM DOOR TO MATCH EXISTING THRESHOLD TO MATCH BUILDING STANDARD Aluminum Door Threshold Scale: 6"=1'-0" NOTE NO. 1 3 TURN WITHI '�... / 45 'MAX.TYP. RUNNER ENDS OPPOSITE WAL 2" MAX TYP TO FLOAT FREE CROSS 'T' ON PERIMETER ANGLE. PROVID 3/4" CLEARANC BETWEEN ENDS OF GRID & WAL Ceiling Bracing Diagram Scale: NTS SHIM AS REQUIRED DOOR PER SCHEDULE 3/8 J DOUBLE STUDS EACH SIDE OF JAMBS BLDG STD HOLLOW METAL FRAME, BLDG STD FINISH Hollow Metal Jam (Head Sim.) Scale: 6"=1'-0" ti HOLLOW METAL DOOR TO MATCH BUILDING STANDARD THRESHOLD TO MATCH BUILDING STANDARD Hollow Metal Door Threshold Scale: 6"=1'-0" ardware Sets: 7'-O" DOOR HAS 1-1/2 PAIR BUTT HINGES. 8'-O" DOOR HAS 2 PAIR BUTT HINGES HS -1 SINGLE NON -RATED DOOR WITH LOCKSET QTY 3 HINGES - TA2714 4.1X4 626 MC QTY 1 PRIVACY - AL4OS Jup 626 SC QTY 1 KICK PLATES - K0050 12"X34" 630 TR QTY 1 WALL STOP - 1270 CVCP 626 TR QTY 3 SILENCERS - 1229A TR HS -2 SINGLE NON -RATED ENTRY STOREFRONT WITH LOCK. ALL HARDWARE TO BE FURNISHED BY STOREFRONT SUPPLIER, INCLUDING BUT NOT LIMITED TO; HINGES,B/S PUSH/PULL, CLOSER, THRESHOLD, AND KEYED LOCK. PROVIDE SIGNAGE ABOVE DOOR TO READ; "DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS". HS -3 SINGLE NON RATED DOOR WITH LOCK SET QTY 3 HINGES - TA2714 44X44 626. QTY 1 LOCK - AL53PD Jup 626 QTY 1 CLOSER -7500 689 QTY 1 ARMOR PLATE -KA050 36"X34" 630 MC SC NO TR QTY 1 WALL STOP -1270 CVCP 626 TR QTY 1 GASKET - S88D17 626 PE * ALL DOORS, FRAMES, AND HARDWARE TO CONFORM TO MOST CURRENT ISSUE OF ICC/ANSI CODE. Good Feet Center Place Floor 1 17066 Southcenter Pkwy Suite 17045 & 17055 Tukwila, WA 98188 DESIGN DRAWN CHECKED NO. Door Schedule: NO. TYPE FRAME HDWE RATING REMARKS REVISION 100A A HM HS -3 100C C WD HS -1 100D B ALUM HS -2 200A A HM HS -3 200C WD HS -1 1413- oal REVIEWED FOR ODAE P R4VE�NCE APR 0 3 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 2 6 2013 PERMIT CENTER JPC RB MP 13-0195 03.01.2013 A 03.25.2013 Permit Drawings Permit Revisions Door Schedule & Details I-10.1 © 2013, JPC Architects, PLLC