HomeMy WebLinkAboutPermit D13-093 - PARAGON PACIFIC - TENANT IMPROVEMENTPARAGON PACIFIC 18270 SEGALE PARK DR B EXPIRED 01/11/14 D13-093 City ctnukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 3523049119 Address: 18270 SEGALE PARK DR B TUKW Suite No: Project Name: PARAGON PACIFIC Permit Number: D13-093 Issue Date: 06/10/2013 Permit Expires On: 09/14/2013 Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKWILA WA 98138 Contact Person: Name: BARRY BENNETT Address: PO BOX 88028 , TUKVVILA WA 98188 Contractor: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUI{WILA WA 98138 Contractor License No: SEGALPL902CQ Lender: Name: SELF FUNDED - SEGALE PROPERTIES Address: Phone: 206-396-2012 Phone: 206-575-2000 Expiration Date: 04/01/2014 DESCRIPTION OF WORK: BLANKET PERMIT: CONSTRUCT TWO NEW OFFICES Value of Construction: $8,300.00 Fees Collected: $433.01 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY **continued on next page** doc: IBC -7/10 D13-093 Printed: 06-10-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N Number: 0 N Start Time: Volumes: Cut 0 c.y. Start Time: Size (Inches): 0 End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non -Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: lD 0-1 3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: Print Name: , /fw `( FC NA✓6-7- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. doc: IBC -7/10 D13-093 Printed: 06-10-2013 7: Ventilation is required for all new rooms and spaces of new or existing buildings and sh e in conformance with the International Building Code and the Washix i State Ventilation and Indoor Air Quality C 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ***FIRE DEPARTMENT CONDITIONS*** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 14: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 17: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 18: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 19: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 22: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinlder heads. (IFC 901.4) 23: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 24: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). doc: IBC -7/10 D13-093 Printed: 06-10-2013 25: Maintain fire alarm system audible/visua tification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visualiili 'cation devices. (City Ordinance #2328) 0 26: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 27: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 28: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 29: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: IBC -7/10 D13-093 Printed: 06-10-2013 /` r - CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httn://www.TulcwilaWA.gov Building. Permit No. i -09 3 Blanket Permit No. b -00e1- - 14 Date Application Accepted: Date Application Expires: °(, k -2j: t 3 (For officeuse only) BLANKET PERMIT TENANT IMPROVEMENT APPLICATION **Please Print** FEES: For office use only Existing (square feet) Amount Receipt No. Date Building Permit Fee $ 259 .70 %�1I� 3 Plan Review Fee $ 1(00.01 tkove(�.flie- 2 Floor State Building Surcharge $ 4.50 Total $ LA 33-0 1 1Z\3-0103ir 3—'13-13 SITE INFORMATION: Valuation of Construction: Site Address: I 89:-.713 Tenant Name: rpo,rn.gc Description of work: Covss4-rvcA ' .sv,3o0 5 ,12 1(-k ��I>Pe King Co Assessor's Tax No.: I /vkwlkkSuite Number: .NIDA r Floor: (..�rou.(o^ tnP� oWiC e5 . Per the International Building Code — 2009 Edition 1. Will there be any structural work? If yes, please describe: 2. Will there be new rack storage? 3. Will there be a change in use? If yes, please explain: 4. Existing fire protection: O Yes 12(' S No O Yes O Yes [r- Sprinklers L3 No No If yes, a separate permit and plan submittal will be required. 0 ....Automatic Fire Alarm 0 .... None 5. Will there be storage or use of flammable, combustible or hazardous materials in the building? If yes, please explain: H:Wpplications\Forms-Applications On Line 12011 Applications\Blanket Permit TI Application • 10.2011.docx Revised: October 2011 bh 0 Yes No Page 1 of 3 Existing (square feet) Construction Area (square feet) Type of Construction per IBC Type of Occupancy per IBC Building Use 1 aFloor %�1I� 3 Ue 1i,.(oc i3 Otte tkove(�.flie- 2 Floor 3rd Floor Floors thru 1. Will there be any structural work? If yes, please describe: 2. Will there be new rack storage? 3. Will there be a change in use? If yes, please explain: 4. Existing fire protection: O Yes 12(' S No O Yes O Yes [r- Sprinklers L3 No No If yes, a separate permit and plan submittal will be required. 0 ....Automatic Fire Alarm 0 .... None 5. Will there be storage or use of flammable, combustible or hazardous materials in the building? If yes, please explain: H:Wpplications\Forms-Applications On Line 12011 Applications\Blanket Permit TI Application • 10.2011.docx Revised: October 2011 bh 0 Yes No Page 1 of 3 PROPERTY OWNER Name: ale "Por Pr- kPS GLC Address: UJ3, 732), s City: /Ukwilc- State: U/A Zip: Fi/ar CONTACT PERSON - person receiving all project communication Name: LYJt64ifh ne++ Company Name: alt. p er%e_5 LCC Address: k re° City: /Ukwrle, State: 0,4 Zip: wig Phone: ,,06.._ 3Q6 a0l d, Fax: o _5,5 _1( 6,a Email: ,r7p 1� p!`. cab rv4Ar i GU 5;6.le- le-il.e5 •COv"•- RD ARCHITECT OF RECORD Name: arou C1 t0,.. As. ev., Company Name: & Are AtUP/iI of Address: / 30 Zakes i06 shite oZSo City: SPaffie State: Gin. Zip:)0 � Phone: a06_ 3�s 31> 5 3 Fax: aoc A1'' ass-41 Email: Hj _ _ I itivt Ueiler.CD GENERAL CONTRACTOR INFORMATION Company Name: (mopa e eS LLG Address: Ft o 5D. D. 'go k City: 117k w r I D. State: ovi Zip: wizi Phone: ,, 06_3"!6' la Fax: ,906,5--,S X6,0 Contr Reg No.: a. SEG ft'LPtiO _ oDate: Lib a0i y L Tukwila Business License No.: �j(/ �1 010 /,330 LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: I hereby certify that I have read and examined this application and know the same to be true and correct, and I am authorized under Blanket Permit Agreement No. I - D"i71- -RA to apply for and obtain this permit. Signature: irY'^ Print Name: 0/1fR "( N/1i677.- Organization:Jffirkk ' Pr 4 -3 Mailing Address: 70. /3_>c. FrOck H:Wpplications\Forms-Applications On Line \2011 Applications\Blanket Permit 11 Application - 10-2011.docx Revised: October 2011 bh Date: 3/i///.3 Day Telephone: 396.-aot'- /Ukw<fo. w44- City State Zip Page 2 of 3 • City of Tukwila Department of Community Development 6300 SoUOicmter Boulevard, Suite #100 Tnkwlla, Wasbingtcn 98188 Phone: 206-431-3670 Parc 206431-3665 • Web site//www. d.iukiv Iawaru Otn PA71T:AG i .=Aret techs' tatemgin ' Plan ReviewNo.: ted Blanket Permit Agreement No.: ptoopI ' I i' ProjectNamx paragon. Pacific Office site Address: 18270 Segale Park Drive B,- Tukwila WA Is any part of the work proposed under this application include ..... . ..... ........_... 0 Yes al No structural work or affect structural components of the building! If yes, has the st uctnral work been authorized by the Tukwila- 0 Yes 0 No Building Official to be included in this application? Does the proposed work comply with the requirements of _.............-............._. j21 Yes ❑ No the International Building Code (3863 Edition) Chapter 10, Means of Egress? 2.co9 Hilo, please explain: Will any special inspections be required per Chapter 17 0 Yea [a No in the International Building Code (2003 Edition)? If yes, list specific inspections: As a result of ibis proposal, does the parking meet the Ea Yes 0 No requirements of the Tukwila Zoning Code? If no, please explain deficiency: ARCHITECT/EN Signature Lanc, Mueller Print Name: orgeronnion: Lance MuellerArchfects pie. 206-325-2553 non , 130 Lakeside, Suite 250 ARMETECT/ENGINEER STAMP AND SIGNATURE 23 LANCE P. Nit:" .ER ATE C *VBeslionailzdeetprodsitlessemareot Canted 9-2004 Seatte WA 98122 CO' sea 77p City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 3523049119 Permit Number: D13-093 Address: 18270 SEGALE PARK DR B TUKW Status: PENDING Suite No: Applied Date: 03/13/2013 Applicant: PARAGON PACIFIC Issue Date: Receipt No.: R13-01038 Payment Amount: $433.01 Initials: WER Payment Date: 03/13/2013 04:01 PM User ID: 1655 Balance: $0.00 Payee: SEGALE PROPERTIES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 634159 433.01 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $433.01 259.70 168.81 4.50 Anr• Pcre in4_11C. Print ad •n4_14_7n1 � INSPECTION RECORD_ Retain a copy with permit X13-CR3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Rermit Inspection Request Line (206) 431-2451 olect: \Ei J Se it, AVE Type offispection: 'Ur 6-31 71,4 WMvJ ,‘ Add eess:' v ,l.7 o E G NLC. '( V DateCalled:_ 1-"� t." CsiVRA N C i -AZ i 0,14) Special Instructions: Date Wa ted: .._ ' — 13 . ,ate �p-t ., Requester: l 1 ,©vel %: 1.�P/ZI a PhoneNo: (, — ~r (,- 1. .,•Ci z® Approved per applicable codes. Corrections required prior to approval. !C COMMENTS: )1z..A fn - ;� � &Jed. C, L A71>_vor_,-- AD) rr VA:1 '-..."— In spector: Date: REIk NSPECTION FEE REQUIRED. Prior' to next inspection; fee rnustbe paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION' RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. a3-013 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 g„ (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: R 6 OA t A' 1 Y Type ,of i spec tioq: n b Address: / Date Called: P K— /71-)1/4_1. f- R n‘ S r rG.•. 4--:` S .)'5' Special Instructions: lt %Z.- (� Date Wanted: r''- a.m. Requester: (iew 49r -r Les Pho e N Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: P K— /71-)1/4_1. f- R n‘ S r rG.•. 4--:` S .)'5' "1 -101F --P __Scrpfj)-S 0 01' )-ff (Q r- n 4 I„ It rte-- C� pi r fl REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspe for: Date 12/2/2013 City of Tukwila Department of Community Development BARRY BENNETT PO BOX 88028 TUKWILA, WA 98188 RE: Permit No. D13-093 PARAGON PACIFIC 1270 SEGALE PARK DR B Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/11/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/11/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Jenn, Perm er Marshall t Technician File D13-093 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • ®pq • ti. �{ r u" 'y� � Y PES. C` ' PLAN REVIEW/ TING SLIP ACTIVITY NUMBER: D13-093 DATE: 03-13-13 PROJECT NAME: PARAGON PACIFIC SITE ADDRESS: 18270 SEGALE PARK DR B X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENT • 31I.I' Building ivision Public Works n Fire Prevention 1111 Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 03-14-13 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04-11-13 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Pripter Friendly Page • General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company SEGALE PROPERITIES LLC 2065752000 Po Box 88028 Tukwila WA 981382028 King Limited Liability Company UBI No. 602023533 Status Active License No. SEGALPL902CQ License Type Construction Contractor Effective Date 2/18/2010 Expiration Date 4/1/2014 Suspend Date Specialty 1 General Specialty 2 Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LAPIALP055MZ LA PIANTA LIMITED PARTNERSHIP Construction Contractor General Unused 7/9/1995 4/1/2001 Archived SEGALBP151M5 SEGALE BUSINESS PARK Construction Contractor General Unused 7/25/1985 7/9/1995 Archived LAPIAL'008J8 LA PIANTA LLC Construction Contractor General Unused 4/28/2000 4/1/2010 Inactive Business Owner Information Name Role Effective Date Expiration Date SEGALE, MARIO A Agent 02/18/2010 Amount SEGALE, MARIO A Partner/Member 02/18/2010 13DLS31006 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 SAFECO INS CO OF AM 6115146 02/18/2010 Until Cancelled $12,000.00 03/28/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Alaska National Insurance Co 13DLS31006 04/01/2013 04/01/2014 $1,000,000.00 03/28/2013 4 Alaska National Insurance Co 12DLS31006 04/01/2012 04/01/2013 $1,000,000.0003/30/2012 3 Alaska National Ins Co 11DLS31006 04/01/2011 04/01/2012 $1,000,000.00 03/29/2011 2 ALASKA NATIONAL INSURANCE COMP 10DLS31006 04/01/2010 04/01/2011 $1,000,000.0003/31/2010 1 ALASKA NATIONAL INSURANCE COMP 09DLS31006 02/18/2010 04/01/2010 $1,000,000.0003/31/2009 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 06/10/2013 ▪ •-•-- • SAN.SEW.M.H. LY -213° 08' 17" R.1134.55 L.259.50 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 2 2013 BUILDING I ISION City of tk ila JAN 11 Ifitn_DM SURVEYORS CERTIFICATE 1 hereby, certify that , this map correctly • represents a survey made by me or under My direction this day of • WATER VALVE 4 WATER METER • ..siCa / • ••... A = 13106'17" R = H64.55 = 266.36 SEGALE PiRiiVT .n.06047' 3 R.1129.89. L.133.98 It , ••• • P.S.P. a L VAULT SPRINKLER VALVES ,RAM SET NAIL IRR. CONTROL VALVE WATER METER a VALVE IDEW L RE Y TELEPHONE LINE N.O,E\RkROUNCI POrVI WATER UNE Esmr• IN \s FAVOR OF KING CO. W.D. 75. 3 130.. RAM ( f. ;33991? ."'* • 11-°"':t5 8 4 7. 1.7474411::::i1117 LSET RAI SIOEW e N 140 n S T ERVICE„ . • 101.05 E QR BAG . 43474 \ Vq\r‘E%)M\ . NORTFIWESTERLY BLDG. LINE k‘ GAS vA v N 07°4624 • OUTSIDE.. LIGHTING ORO'PERTiedORNER' CASED. MONLIMENT,f: RAMSE'T NAIL FILE Permit No., • Plan review approval Is subject to wrors and omissions. 4,-.ovai of Construction documents does not authclize .thc v:otation ot any adopted code or ordinance. Rem., of approved Field Copy.and condthons BY REVISIONS No changes shall be made to the semi . . of work without prior approval of Tukwila -Building Division. • tr77:: rsv:sinne-wiii require a new slap submktal LL7,0 may in4!ude addilionat plan review foes. COVERED END WATE R ESPAT. City Of Ilikvolla BUILDING DIVISION .LEGAL DESCRIPTION :PARCEL NO 1 That portion,ofthe. Southweat Quarter of t e: Northeast Quarter and•GoliernMent..• Lot 5 ALL in SeCtion35, Township 23 Northi Range 4 East, in King County, . Washington., described. as..follows:. BEGINNI*G at a monument at the Northeast •c rner• of the said Southwest Quarter of the Northeast:Quarter;.thence South 07°44'56" West, 500..14 feet T thence • North,87°50109m. West.212:.77 feet to the -TRUE PQINT'OF.BEGINNING; thence along. a 14." curve to the .left whose center -bears South 48°22'43" East, having. a radius. of 409.256 .feet., through.a central angle, of 22°12'21" an arc distancelof 158.61 feet;',thence.South19°24'56." West, 101.32 feet to. the Northwest corner.of.Parcel 731, as recorded under. King County Auditor's File No. 7512040188;.thehce con-. tinuinT'South.19"24'56" West, .59.97 -feet.to' a point of curve; thence along a,- 12°.curVe..tb.theleft having.a radius of 477.47 feet. through a central angle:of, 11"40-'.00".anarc distance of 97..22 feet, thence South 07°44'56" West,1213.72 feett.6 the:Southwest corner.of said Parcel 731; thence continuing South, 07°44'56" West,,48.23'.feet to a:point of:curve; thencealong a 12° curve to.thelright ' • having a.radius: Of 477.47 feet.through a central angle of 13°00'00".an arc dia.-. tance.of 108.33 feet;..thence South 20°44'56" West, 399.00 feet to thelSouthwest • cornet of Parcel 733as. recorded under. King•County Auditor's File No. 75070300757 . COVERED L 7.1083 • • R.R. SPUR TRACK •J "..mummommommom 0 I • 26' ESMT. IN FAVOR OF CHICAGO MILWAUKEE--0- .ST. PAUL AND PACIFIC RR., UNION PACIFIC R.R., AND OREGON AND WASHINGTON R.R. AND NAVIGATION CO. AUD. FILE NO. 7707080078 • r) CB R\\\% R.R.LEAD'TRACKS' • 'PUNCH MAR CROSS ' ARM FOR SWITCH . RESERVING.an'easement.for sidewalk and utility purposes over; the 15.00 feet, over the. Westetly:15.00.feet and over the Southwe terly 15.00 feet thereof.; .. . RESERVING .the right of ingress and egress .o maintain,, instal . . . 'extend utilities.. • . ' RESERVING aneasement for railroad.purposes, including, but not limited to . ' maintrack, lead track and spur tracks, as well as for access.and storage, Over that.portion:.thereof lying.Southeasterlof the Southeasterly building line ' produced.. • . . . . • • . • . . . . .RESERVIN. G an eaiement for waterline.purpoSes:15 feet' wide, haVing 7.5 -feet. , . . . on each side of the followingdes,c.rbed:ce.n'er.l.ine: . . • " .• . BEGINNING at.a.Monument at the Northeastcorner. of the Southwest Quarter of . . . . . . . . _ . . .. . the Northeast Quarter,of.the said.Section.35;..thence South 07°44'56 West, 500A4 -feet;. thence. North.87°50'09," West, 329.73' feet; thence South 07°13'41" West, 15.06 feet to the TRUE. POINT OF BEGINNINGrthence continuing South 07°13'41" West, 246.77.feet to the terminus.,„ . ... . . . . RESERVING an easement.for coMmon access purposes, including. ingress and: egress over, the following described portion thereof: • ,.. improve and thence continuing South. 20°44'56" West, 511.97 feet to the Southwest corner.of ' Parce1:752'as.recorded under•King:County'Auditor's File No. 7608160055; thence North'66°31'27" West,. 270.97 feet to a:point of curve; thence alonga.curve to . the right having a radiusof 50.00 feet throughsa central angle of 87'18'52" an arc distance of .76'.2.CG,feetv thence NOrth. 20°47'25" East, 791.84. feet to a point' of curve; thence alonT.a cutve*to the•left having. a radius of 1,164.55 feet through a central angle of 13°06'17" an arc distance of 266.36 feet; thence North 07°41'08" .East, 206.95 feet to. a point of curve; thence along a curve to ,the right.having a radius of:1,0.99.89 feet through a central angle of06°47'39" an-,Atd.diatance..of 130'.42leet;.thence.North.14°28'47" East, 82.13 feet to a,„. pointofcutve;thencealong,-a_curveto:the,right having a radius of 40.00. feet .through acentra1 ang1€ of 77°41'04an.ara•distance of 54.23.feet; thence--; South.87!50'0.9East56.7g:'feet tcithe. TRUE...POINT:OF BEGINNING. ; BEGINNING at a.monument at.the.Northeast. corner:of the Southwest Quarter. of the Northeast Quarter of thesaid Section 35; thence South 07°44'56" ' West, 500.14 feet; thence North. 87°50'09", West,.212.77.feet to the .TRUE POINT OF BEGINNING; thence along a:14° curve.to-the left.whose center bears South- 48°22143".East, having a, radius:of 409.256.feet; through a central angle of: 19.°54.141".an,arc'distance of 142.22.feet;."thence North 82°30'02". West, 6682 ' .feet&:thenceNoith 07°46'15,"-EAA';. 117.51 feet, thence South 87°5Q'09" -East, 124'..7.4:_feettothe:TRUEPOINT,OFBEGINNING..... ,. :STYE. AnDRESS: . . . ,_.-18ZOCH$31-0.. SEGALE ;PARKADRIVE ..13 TOGETHER WITH AND SUBJECT TO an easement for building setback purposes over a 60 feet wide strip of land surrounding and adjacent to the main building line which is described as follows: B'EG/WNING.at a monument atthe Northeast corner of the Southwest Quarter of the Northeast Quarter of the said Section 35; thence South 07°44'56" West, 500.14 feet; thence North 87°50'09" West, 337.51 feet; thence South 07°46'15" * West, 117.51 feet to the TRUE POINT. OF BEGINNING; thence continuing South 07°45'15" West, 537.39 feet; thence South 20°45'48" West, 949.8 feet; thence North 69°16'09" West, 209.96 feet; thence North 20°46'05". East, 116.00 feetP 'thence South 69°13'56" East, 20.00 feet; thence North 20°46'05" East, 637.87.... feet; thence North 69°13'55" West, 20.00 feet; thence North 20°46'05" East, 123.59 feetp thence South 82°13'36" East,- 10.77 feet; thence North 7°46'24" . East; 24.00 feet; thence South 82°13'36." East, 20.00 feet; thence North 07°46'24” East,',434.74 feet;. thence North 82°13'36" West, 20.00 feet; thence North •!! 07°46'24" East, 101.05 feet; thence South 82°30'02" East, 210.01 feet to the TRUE POINT OF BEGINNING'. IRON PIPE PLASTIC CAP " .•. , . tr.ilq,;.MONUMENT TH'Ei:CNTERLINE• S;.l8OTHST.A pugoc:, STRE ••• (See sheet 2 for continuation) • 21J!.. in2{10\\1:119:[0): • ••TI.AitT1/4:Giii:VE4P.;-:. • AigielNG - g2o57:47er • • • ' • ATTACHMENT #1 SBP/MAS BUILDING 763 �49:_VW.2M•wrmUmm mamma. -or M:r....,,....aJ>;C::.e%rfPwl•+'%M.JItCA:L:.:.t�Slg4.#e!i!NA.d12M + ... Lbl� WATER, VALVES PANSET NAI, 15' = 87°18' 52 R = 50.00. L 2 76.20 WATER VALVES ATER METERS AANSET NAIL 1N, 910 E WALK • SAN. SEW. M.H. 0 M f• 1 1 N 200 47'25" E '. SEGALE PARK DRIVE ii WATER. HALVE • WATER METER • • � • • - -- ---- 11- -7-7 :We" ET7 ' SAN. SEW. M.H.'. • • nm+ ....,. • -oBso. im,P._= .. stm-'.1 _.svk •;c x:•_'+?u5rr .. '_^ ••': `..F:!Nwrnm: 1L_•.^_"x:'_''•'"S_':J;' • • • • • • • •.1 • ii�4S I NAIL . WATER LVE WATER ME TER .r:'•':' ° •,SI! WALK ;•, :r .:; •sa ... 'i' N • „...;1TMdIW►iMM►,� R ESMT. —} ;`•Water';• in'e" o• n f avoir'•o f ' King Couny' as recor.ded•under Auditor's File .No.:,780302 1 1 • • PROPERTY:' ro IRR: CONTROL VALV WAITER VALVE:... WATER METER' Io° .c.l. NATER -WATER PIPE GAS VALVE \\\\\\\VM N 20°46 05 E 116.00 . - NORTHWESTERLY, BLDG_ LINE SPRIN L• R METER \\\\\\\\\\\\\ CO RCL. • LVE SPRINKLER 30' z • J U R.R.SPUR TRACK ' " 30.03!• R.R. SPIKE PUNCHED '''":•-END PAVEMENT R.R. SPUR •TRACK . • TRACK EASEMN1_ „, 20' ESMT. IN FAVOR OF CHICAGO MILWAUKEE S7: PAUL AND PACIFIC R.R. UNTQN PACIFIC RIR AND OREGON AND WASHINGTON R.R. ANO NAVIGA 10 AUD. FILE NO. 7707080076 \\\\\VA\A"\\-\\% \\\ .%\\‘. `'(LEGAL DESCRIPTION CONTINUED) EXISTINGVVAREHOUSE•. I • .BLDG.. NO..752 • • t TOGETHER 'WITH a. non exclusive easement for ingress, egress, and utilities.. purposes, • 60 feet' inwidth, having .30. feet' on.• each• side of the 'following • described. centerlines. .• BEGINNING at a' monument at the N '. theast 'corner of.,, the Southwest 'Quarter of the Northeast• Quarter. of Section.. 5; Township 23 North,. Range 4 •,East;. W.M. ..• in• King' County,. Washington; then a South. 07.4'44'561' West, 470.00 feet; thence North 87'650.'09".West; .• 628: 86 • feet; 'thence-, South 14'28'47" West, 138.49 feet to a point•, of curve; thence • along • •a curve to the left . having a ''radius.'•of • ' 1,129'.89. feet, through •a central angle of..6°47'.39", . an • rc distance • of 133.9 feet.;, thence South, 07641'08H' We' iii • 206.95 feet to a point of curve; .thence. along a curve to. the right hav , •g 'a.•radius' of 1,134.55 feet •through a. centra angle of 13°06'17"•,..an arcdistance of 2.59.50 feet; thence South 20°47'25". . West,' 868.17 feet; thence Sout 66.31'27" East, 347.30 feet • to'. the• terminus' of this easement centerline'. CCEPT••that portion thereof• lying .within, South o 180th Street.. •••FIRE HYDRANT AND 'VALVE ' • . . . %\\% \S\IM . . LEGEND. • • • (3) The 'route 'o£ said 'relocated. easement shall' afford reasonably -,direct • accesstoa public road;• I: • •• • (.4'.) •,' The legal rights, of Mortgagee- and'• Mortgagee's• successors thereunder,:'•im and to route :'of. said.relocat.ed easement ''shall •be!substantially:.,the same as: '•.' :•w .t:h respect. to .the route• of the initial:•easement;• , ,' , • (5) ' Sa•id'• r•elocate'c ,leasement• shall•,be.•app•ropriately: documented by''a supple 8 ,ment to; this . Assignment containing a: revised legal d'esoription',and•'shall ,• ,.. • . ••• • . • be insured at :the .expense • of Owner by a ,title insurance; company 'on the same'; • basis as' the original, relocatable easement:. • �••►. • x 6 x • The • eenses. of such: relocation,. including ' the construction glad sue...* ;•• ' •: facing' t=hereof, , shall.• be the sole responsibility of Owner or• Owner's ' SUBJECT, HOWEVER, to' the'righr of Owner .and Owner's successors in title, 'to ))relocate said easement withint Segale .Business Park on the following. terms• • and conditions: , . • . • . • • • ' (1) • Any such .•relocation sh •h. perpetuate similar rights of ingress, egress. land utilities. to 'a' public '.ro4sdj' ' • (2) •' The width cif said relocated easement' and the physical • surfaoing.thereof• .. shall •be similar' to that of:..'the .initial:: easement; • • . PROVIDED,. HOWEVER, that no such relocation 'shall be; permitted` if, in• opinion of independent;,' real estate appraiser (M.A. i.) , as .selected' by mortgagee,- the. fair' market value'• of the. secured' .property as of. the date. of • relocat,ion. of, • said r easement would be'•reduced • by 'reason • ©€ such : reloca- ',. ! tion • below the •: f air •• market value .;of the;' s eeured ' property as of :the d • ate' of.:. I execution • of this As•s•ignmerit, as • determined by'•..the Mortgagee prior.. to the' • I ;.execution date• hereof.... The expenses: of" such. . appraiser' shall, be, paid: by( the •. • Cwner• 'or Owner's.;,successor• irr •title.,. .. • 1fIEED FOR RE . C4DE COMPLIANCE CE APP.. MAR 222013 ' City of Tukwila BUILDING DIVISION . CB CATCH 15 ASI14•' ': DS•. • DOWN :,SPOUT'': ': STORM.' SEWER, .. G ' NATURAL: • GASI: . WATER;: ' i''•' .: 9 , .FIRE HYDRANT ' .. -- ' .SANITARY SEWER-.; ' -E-----. ,ELECTRt'CAL•, • OUTSIDE'L,IGH,T(Ne'::. ,.• el • CASED MONUMENT•. • ••S . O .. PROPER.TY 'CORNER' • ' ... ' . �� •RAMSET..NAIL; IT -E, AO RE • S • 0 • PARKING •A -+ , 14 y<, C/. COMF C l I� 1 1y 1t •.:. �Cr .a' 1.,,,,i.i, •„,::.'".:.$1:..t• 3 1• R • • • . • •6_._ r-1., a ^.. a\l‘‘‘‘\% REC'EIV.•ED•:' CITY, O'P.t•U,I.{;WIL•A" MAR..1'3x. 013.• . PERMil` C.EINTER oAwn oft Ana MM.Ok mmomimion . . . RRvisk' 1rn7/e Lim- e'doing '166 _n&tSton SURVEYORS '' . CERTIFICATE 1 hereb aertify' ttof this mop correctly:” •, • represents. a survey • made :.by me: ar`• udder: my ditertton..:;this. .da�t•.'of.= :!*w+ f � ; • ,.� Registered Land Surveyor . L.S.; No. •. '18204 8340. SEGALE _PARK 'DRIVE - V 1 • 324-77 • , • o • y �,; ik�•'14,_ 'i7., :.-.. '".. ..l.�f 'v•.'�k:1•:r. .l.`r. t,.. .. �:: !. •t<1.• .7f.�."::•r F:f� .'1'`��•rti .:•• II•iIIIIIw►!�IIII 10111111 U W '("ID" AREA OF WORK THIS PERMIT REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 2 2013 OVERALL FLOOR PLAN 50 BUILDING 763 INDEX OF DRAWINGS TA1.0 OVERALL PLAN / COVER SHEET TA2.0 OVERALL TENANT SPACE TA2.1 1/8" FLOOR PLAN & REFLECTED CEILING PLAN & NOTES & DETAILS TYPE OF CONSTRUCTION: OCCUPANCY GROUPS: PROJECT TEAM TENANT: TENANT AREA: TYPE V—B, SPRINKLERED B (OFFICE) S-2 (STORAGE) EXISTING OFFICE EXISTING RESTROOMS EXISTING WHSE./STORAGE TOTAL AREA 4,320 S.F. 390 S.F. 70,390 S.F. 75,100 S.F. THIS TENANT IMPROVEMENT WILL USE IBC SECTION 302.3.1 NONSPEPARATED USES TO ELIMINATE THE REQUIREMENT FOR SEPARATION OF USES. PARAGON PACIFIC ARCHITECT: LANCE MUELLER & ASSOCIATES 130 LAKESIDE, SUITE 250 SEATTLE, WA 98122 (206) 325-2553 FAX. (206) 328-0554 CONTACT: HAROLD CHRISTENSEN Email: haroldc©Imueller.com SCOPE OF WORK THIS TENANT IMPROVEMENT IS IN AN EXISTING OFFICE SPACE. PROPOSING TWO NEW PRIVATE OFFICES WITHIN EXISTING OPEN TO INCLUDE NEW WALLS, DOORS AND WINDOWS. NO CHANGE CEILING OR LIGHTING. CODES THE TENANT IS OFFICE SPACE. WORK TO EXISTING SUSPENDED RECEIVED CITY OF TUKWILA MAR 1 3 2013 PERMIT CENTER NATIONAL CO 2009 INTERNATIONAL BUILDING CODE 2009 INTERNATIONAL MECHANICAL CODE JAN JAN iii 11112O( 2009. INTERNATIONAL FIRE CODE 2009 INTERNATIONAL ELECTRIC CODE WASHINGTON STATE AMENDMENTS 3/7/2013 8:57:06 AM GENERAL CONTRACTOR: SEGALE CONTACT: BARRY BENNETT Email: bbennett®segaleproperties.com WAC 51-40 WASHINGTON STATE BUILDING CODE WAC 51-42 WASHINGTON STATE MECHANICAL CODE WAC 51-44 WASHINGTON STATE FIRE CODE WAC 51-46 WASHINGTON STATE PLUMBING CODE WAC 51-47 WASHINGTON STATE PLUMBING STANDARDS WAC 51-11 WASHINGTON STATE ENERGY CODE WAC 51-13 WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE r.-) a) 0 BUILDING PERMIT SET C 0 (/) '> 0 L 0 0 13-031 job no. HC drawn checked re) I I r,-) a) O -0 U W '("ID" AREA OF WORK THIS PERMIT REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 2 2013 OVERALL FLOOR PLAN 50 BUILDING 763 INDEX OF DRAWINGS TA1.0 OVERALL PLAN / COVER SHEET TA2.0 OVERALL TENANT SPACE TA2.1 1/8" FLOOR PLAN & REFLECTED CEILING PLAN & NOTES & DETAILS TYPE OF CONSTRUCTION: OCCUPANCY GROUPS: PROJECT TEAM TENANT: TENANT AREA: TYPE V—B, SPRINKLERED B (OFFICE) S-2 (STORAGE) EXISTING OFFICE EXISTING RESTROOMS EXISTING WHSE./STORAGE TOTAL AREA 4,320 S.F. 390 S.F. 70,390 S.F. 75,100 S.F. THIS TENANT IMPROVEMENT WILL USE IBC SECTION 302.3.1 NONSPEPARATED USES TO ELIMINATE THE REQUIREMENT FOR SEPARATION OF USES. PARAGON PACIFIC ARCHITECT: LANCE MUELLER & ASSOCIATES 130 LAKESIDE, SUITE 250 SEATTLE, WA 98122 (206) 325-2553 FAX. (206) 328-0554 CONTACT: HAROLD CHRISTENSEN Email: haroldc©Imueller.com SCOPE OF WORK THIS TENANT IMPROVEMENT IS IN AN EXISTING OFFICE SPACE. PROPOSING TWO NEW PRIVATE OFFICES WITHIN EXISTING OPEN TO INCLUDE NEW WALLS, DOORS AND WINDOWS. NO CHANGE CEILING OR LIGHTING. CODES THE TENANT IS OFFICE SPACE. WORK TO EXISTING SUSPENDED RECEIVED CITY OF TUKWILA MAR 1 3 2013 PERMIT CENTER NATIONAL CO 2009 INTERNATIONAL BUILDING CODE 2009 INTERNATIONAL MECHANICAL CODE JAN JAN iii 11112O( 2009. INTERNATIONAL FIRE CODE 2009 INTERNATIONAL ELECTRIC CODE WASHINGTON STATE AMENDMENTS 3/7/2013 8:57:06 AM GENERAL CONTRACTOR: SEGALE CONTACT: BARRY BENNETT Email: bbennett®segaleproperties.com WAC 51-40 WASHINGTON STATE BUILDING CODE WAC 51-42 WASHINGTON STATE MECHANICAL CODE WAC 51-44 WASHINGTON STATE FIRE CODE WAC 51-46 WASHINGTON STATE PLUMBING CODE WAC 51-47 WASHINGTON STATE PLUMBING STANDARDS WAC 51-11 WASHINGTON STATE ENERGY CODE WAC 51-13 WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE 3/7/2013 8:59:35 AM EXISTING TENANT DEMISING WALL EXISTING TENANT DEMISING WALL SEE SHEET TA2.1 FOR 1/8" OFFICE PLAN 1 0 0 CONF. ROOM (E) OPEN OFFICE (E) OFFICE ( E ) NEW NEW OFFICE OFFICE (113) (114) 0 HALL rn OPEN OFFICE ( E ) BREAK n ROOM Ell ( E ) BREAK ROOM MID OPEN OFFICE (E) LOBBY ( E ) EXISTING OFFICES TO REMAIN EXISTING RAMP TO REMAIN NORTH FLOOR PLAN 0 8 16 32 48 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 2 2013 City of Tukwila BUILDING DIVISION ,AN 1 t ice, 2v(cf RECEIVED CITY OF TUKWILA MAR 1 3 2013 PERMIT CENTER LO3 REGISTERED N) co M N IMPROVEMENT Z 1- Z 0 CDQ OC Q a 1— ce W —JW t/) N 00 0 O 0 PLAN OF TENANT O w H U O N cn MUELLER (1) U w 1- U O 30 LAKESIDE 0 J sheet TA2.0 I n r, a) } BUILDING PERMIT SET__ C O_ U .� N L r N ^ 111111111 O r- C O O 0 HC drawn checked REGISTERED N) co M N IMPROVEMENT Z 1- Z 0 CDQ OC Q a 1— ce W —JW t/) N 00 0 O 0 PLAN OF TENANT O w H U O N cn MUELLER (1) U w 1- U O 30 LAKESIDE 0 J sheet TA2.0 3/7/2013 9:01:10 AM FLOOR PLAN SYMBOLS SYMBOL FIXTURE EXISTING BUILDING SHELL WALL 2' X 4' ACOUSTICAL LAY -IN CEILING PANELS WITH 1516" HEAVY DUTY SUSPENDING GRID SYSTEM NEW WALL PER FLOOR PLAN N) I M OFFICE TENANT ROOM NAME & NUMBER (105) E WALL TYPE REFERENCE a DOOR/WINDOW NUMBER / DOOR/WINDOW TYPE RATING (MINUTES) 237BI B 13120 \ GROUP HARDWARE FE SEMI -RECESSED FIRE EXTINGUISHER CABINET CEILING PLAN SYMBOLS SYMBOL FIXTURE 1 - 2' X 4' ACOUSTICAL LAY -IN CEILING PANELS WITH 1516" HEAVY DUTY SUSPENDING GRID SYSTEM 1 1 N) I M a o MI a a X 4' FLUORESCENT 18 CELLS PARABOLIC LIGHT FIXTURE - 3 LAMPS 1 Wil2' BUILDING PERMIT SET ---- 2' X 4' FLUORESCENT 18 CELLS PARABOLIC LIGHT FIXTURE - 3 LAMPS W/ NITE LIGHT ® r 2' X 2' FLUORESCENT 18 CELLS PARABOLIC LIGHT FIXTURE - 2 LAMPS 13-031 job no. HC drawn checked LIGHTOLIER RECESSED COMPACT FLUORESCENT 63/" DIA. WITH SPECULAR CLEAR REFLECTOR 26W - METAL HALIDE WAREHOUSE FIXTURES, 250W WALL MOUNTED EXIT SIGN © + 84" AFF EXIT WM CEILING MOUNTED LIGHTED EXIT SIGN EXIT CM DIRECTIONAL LIGHTED EXIT SIGN EXIT WALL MOUNTED EMERGENCY LIGHTING + 12'-0" AFF CEILING NOTES 1. ALL SWITCHES TO BE LOCATED AT +48" AFF TO CENTER OF SWITCH UNLESS NOTED OTHERWISE. MULTIPLE SWITCHES TO BE GANGED TOGETHER AND FINISHED W/ ONE COVER PLATE. 2. ALL COVER PLATES TO BE WHITE. 3. ELECTRICAL SUBCONTRACTOR TO PROVIDE EMERGENCY PATHWAY LIGHTING USING SELECTED LIGHT FIXTURES. 4. ALL GYPSUM CEILINGS TO BE INSTALLED AT +8'-6" AFF UNLESS NOTED OTHERWISE. 5. INSTALL ALL ACOUSTICAL SUSPENDED CEILINGS ® +9'-0" AFF UNLESS NOTED OTHERWISE. 6. CENTER ALL FIRE SPRINKLER HEADS IN CEILING TILE IN TWO DIRECTIONS. 7. INSTALL RECESSED FIRE SPRINKLER HEADS IN ALL GWB CEILINGS. 8. ALL ROOMS SHALL BE PROVIDED WITH LIGHTING OCCUPANCY SENSORS PER SECTION 1513 WASHINGTON STATE BUILDING CODE. FLOOR NOTES 1. ALL DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTES OTHERWISE. 2. GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR FIELD VERIFYING EXISTING CONDITIONS AND NOTIFYING ARCHITECT OF POTENTIAL CONFLICTS PRIOR TO START OF WORK. DOOR & WINDOW TYPES 3'-0" 0 A 3'-0" X 7'-0" FLUSH WOOD DOOR W/ TIMELY PREFINISHED METAL. FRAME HARDWARE GROUPS 0 • 0 AA 5'-0" X 4'-0" W/ y4" TEMPERED GLASS W/ TIMELY PREFINISHED METAL FRAME HW -1 1Y PR. BUTTS LEVER LOCKSET WALL STOP SILENCERS EXISTING R-30 INSUL. OVER CEILING EXISTING SUSPENDED - CEILING SYSTEM PER REFLECTED CEILING PLAN 3 5/8" X 25 GA. METAL STUDS CO 24" O.C. WITH 5/8" GWB EACH SIDE 1 3y" SOUND BATT INSULATION SEE FLOOR PLAN FOR LOCATION 1/8" DIA. X 1" POWDER ACTUATED FASTENERS 24" O.C. EXIST. CONC. SLAB INT, WALL TO SUSP. CLNG. SCALE: 1 /2" = 1'-0" 115'-2" EXISTING CONF. ROOM EXISTING OFFICE 3'-6" EXISTING OPEN OFFICE 11'-13/8" 12'-138" (Tui NEW OFFICE NEW PRIVATE OFFICES WITHIN EXISTING OPEN OFFICE AREA 0 0 EXISTING RESTROOM -0)E 0 0 EXISTING RESTROOM ord EX HALL G 105 FEC EXISTING OPEN OFFICE 104 EXISTING BREAK ROOM 102 EXISTIN BREAK ROOM L. 7.0 N EXISTING OPEN OFFICE LS 0 L. 0 EXISTING LOBBY • in 6- II NORTH 0 1- in i•0 J 1'-0'3 ,L EXIST. CONC. STAIRS & RAILING L.S. 5'-O" EXIST. HC RAMP iNI N EXISTING RAMP FLOOR PLAN Lj..81 16 24 (2) NO. 12. WIRES EACH WAY(90') ® 8'-0" O.C. PER ICBG REPORT # 4071 SUSP. CEILING GRID 1/4" DIA. EYE BOLT W/ NUT & WASHER EACH SIDE OF TOP TRACK 11 0 on 111 111111111 9'C nom III I 1111 111 'J' EDGE BEAD DEEP LEG TOP TRACK PAINT BLACK 1/4" NEOPRENE SPACER 5/8" GWB ON METAL STUDS TOP OF WALL BRACING SCALE: 3" = 1'-0" REVIEVVED FOR CODE COMPLIANCE APPROVED MAR 2 2 2013 City of Tukwila BUILDING DIVISION EXISTING SUSPENDED CEILING AND LIGHTING TO REMAIN AS -IS. -01 RE-CErVED CITY OF TUKWILA MAR 1 3 2013 REFLECTED CEILING PLAN. PERMIT CENTER NORTH 0 4 8 16 24 1 1 1 - 1 - 1 1 N) I M a o MI a a 1 BUILDING PERMIT SET aE Nf co * r r 13-031 job no. HC drawn checked N-) N 1 m I 0 in 73 .- 11'-13/8" 12'-138" (Tui NEW OFFICE NEW PRIVATE OFFICES WITHIN EXISTING OPEN OFFICE AREA 0 0 EXISTING RESTROOM -0)E 0 0 EXISTING RESTROOM ord EX HALL G 105 FEC EXISTING OPEN OFFICE 104 EXISTING BREAK ROOM 102 EXISTIN BREAK ROOM L. 7.0 N EXISTING OPEN OFFICE LS 0 L. 0 EXISTING LOBBY • in 6- II NORTH 0 1- in i•0 J 1'-0'3 ,L EXIST. CONC. STAIRS & RAILING L.S. 5'-O" EXIST. HC RAMP iNI N EXISTING RAMP FLOOR PLAN Lj..81 16 24 (2) NO. 12. WIRES EACH WAY(90') ® 8'-0" O.C. PER ICBG REPORT # 4071 SUSP. CEILING GRID 1/4" DIA. EYE BOLT W/ NUT & WASHER EACH SIDE OF TOP TRACK 11 0 on 111 111111111 9'C nom III I 1111 111 'J' EDGE BEAD DEEP LEG TOP TRACK PAINT BLACK 1/4" NEOPRENE SPACER 5/8" GWB ON METAL STUDS TOP OF WALL BRACING SCALE: 3" = 1'-0" REVIEVVED FOR CODE COMPLIANCE APPROVED MAR 2 2 2013 City of Tukwila BUILDING DIVISION EXISTING SUSPENDED CEILING AND LIGHTING TO REMAIN AS -IS. -01 RE-CErVED CITY OF TUKWILA MAR 1 3 2013 REFLECTED CEILING PLAN. PERMIT CENTER NORTH 0 4 8 16 24 N) I M a o MI BUILDING PERMIT SET c 0 (/) > a. S.- 13-031 job no. HC drawn checked N-) N 1 m I 0 in 73