Loading...
HomeMy WebLinkAboutPermit D13-113 - BLACK BEAR YOGURT - TENANT IMPROVEMENTBLACK BEAR YOGURT 17250 SOUTHCENTER PY EXPIRED 12-14-13 D13-113 Ci411) ty Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 7888920020 Address: 17250 SOVTHCENTER PY TUKW Suite No: Project Name: BLACK BEAR YOGURT Permit Number: D13-113 Issue Date: 05/21/2013 Permit Expires On: 11/17/2013 Owner: Name: WIG PROPERTIES LLC -SS Address: 4811 134TH PL SE , BELLEVUE WA 98006 Contact Person: Name: ZACH MILLER Address: 5700 100 ST SW, SUITE 330-152 , LAKEWOOD WA 98499 Contractor: Name: FINAL CUT CONSTRUCTION Address: 9927 98 ST SW , TACOMA WA 98498 Contractor License No: FINALCC977B 1 Lender: Name: SELF FUNDED - TENANT (BLACK BEAR YOGURT) Address: Phone: 253-212-7882 Phone: 253 222-7723 Expiration Date: 03/09/2014 DESCRIPTION OF WORK: TENANT IMPROVEMENT TO INTERIOR SPACE, REMODEL FOR FROZEN YOGURT AND ESPRESSO RETAIL SALES. Value of Construction: $140,000.00 Fees Collected: $2,977.64 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: II -B Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY **continued on next page** doc: IBC -7/10 D13-113 Printed: 05-21-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: N N Water Main Extension: Water Meter: N Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Private: Public: Profit: N Non -Profit: N Private: Public: Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permi Signature: Print Name: --r-k1 0.4 a S R &yj o/ �/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: 5721 / ( 3 PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: The special inspections and verifications for concrete construction shall be required. 6: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 7: The special inspection of bolts to be installed in concrete prior to and during placement of concrete. doc: IBC -7/10 D13-113 Printed: 05-21-2013 8: When special inspection is required, ei the owner or the registered design professin responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 9: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 10: New suspended ceiling grid and light fixture installations shall meet the non -building structures seismic design requirements of ASCE 7. 11: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 12: Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with the recommendations given in the soils report. Special inspection is required. 13: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 14: All food preparation establishments must have Seattle/King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle/King County Department of Public Health, (206/296-4928), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 15: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 16: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 17: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 18: Manufacturers installation instructions shall be available on the job site at the time of inspection. 19: A Certificate of Occupancy shall be issued for this building upon final inspection approval by Tukwila building inspector. 20: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 21: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 22: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 23: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Thkwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 24: ***FIRE DEPARTMENT CONDITIONS*** 25: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 26: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 27: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation doc: IBC -7/10 D13-113 Printed: 05-21-2013 instructions. Portable fire extinguishers havin ross weight not exceeding 40 pounds (18 kall be installed so that its top is not more than 5 feet (1524 mm) the floor. Hand-held portable fire extingui s having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1x67 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 28: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 29: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 30: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 31: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 32: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 33: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 34: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 35: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 36: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 37: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1006.1, 1006.2, 1006.3) 38: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 39: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 40: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 41: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 42: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention doc: IBC -7/10 D13-113 Printed: 05-21-2013 Bureau. No sprinkler work shall commenc1thout approved drawings. (City Ordinance 327). 43: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 44: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 45: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 46: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 47: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 48: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 49: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 50: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 51: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 52: ***PUBLIC WORKS DEPARTMENT CONDMONS*** 53: Prior to final permit sign -off contractor shall perform a die test to be witnessed by PW inspector to assure that the grease waste line is tied to the existing ouside grease interceptor. doc: IBC -7/10 D13-113 Printed: 05-21-2013 • • CITY OF TUKWILA Community Development Deparnnent Public Works Department Permit Center 6300 Sontheenter Blvd, Suite 100 Tttku ilct, W.4 98188 http://www.Tuk:wilaWA.gov 11111 Building Permit No. \) (-- 1 . 3 Project. No. Date Application Accepted: 4'4 t 3 Date Application Expires: 1.0 —(0-t 3 (For office use onto CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 1-1 2Z.E0 so U *\ ueM fr_ ./ 4 t Lig Site Address: 1 l -L60 S o CPi 4 -e -r- ( lc, Tenant Name: Q ia c k er cat" King Co Assessor's Tax No.: Suite Number: ( ( ' Floor: Pk"' i\ yd llar�' PROPERTY OWNER Name: --)1 i 11 „ _ _ %A S %,--,wl' Address: 5i©o 10 oil, 5 skSW STE 33D 152_ Name: a i U ernptir 5 Email: (' t t1„ ' "/ 3 p 2gi/hC't.' .C' OM Address: tt t I -2.11/4-W- ‘`)- se City: City: e., k Le_v �, Stale: / Zip: c �7 006 CONTACT PERSON - person receiving all project communication Name: --)1 i 11 „ _ _ %A S %,--,wl' Address: 5i©o 10 oil, 5 skSW STE 33D 152_ City: LA w 006( State: wA- Zip:91i'[ eil 1 I E: Phone: 2 53-1(Z.'-� gcz F Email: (' t t1„ ' "/ 3 p 2gi/hC't.' .C' OM GENERAL CONTRACTOR INFORMATION Company Name: '� Architect Name: bavd Sa,G'L Address: 2,2,k461go.- 4w_ se Address: Phone: 2o(o. b (--7.1U16ax: Email: e5 cJ0.A. * co yv �, Ci v ► a am, City: State: Zip: W __ Phone: Fax: Contr Reg No.: Tukwila Business License No.: Exp Date: f _ OV7 iI H:.3pplicatica9 Fenn Appluatimu Oa Lu e .0:3 Appli:ations Pe:mit ApplicaficaRevised. • S 4 tt.ducs Kesised: August 2011 bh Nen Tenant: Yes ❑..No ARCHITECT OF RECORD Company Name:Low sovxh Architect Name: bavd Sa,G'L Address: 2,2,k461go.- 4w_ se City: wr. . rS tu4 State: Zip: q g01.{0 wA. Phone: 2o(o. b (--7.1U16ax: Email: e5 cJ0.A. * co yv �, Ci v ► a am, ENGINEER OF RECORD Company Name: POrkr. IAA r Engineer Name: Er y ,`� V ri1 Address: q(1 ,p, R300 City: 1 State: � Zip:t;�gtn Phone: 2u,,3N3.04(x©ax: 2t�lo_ 3'-f �. Jrio�1 Email: ` tt i 'e ok. t'�C��anC.CO0 LENDER/BOND ISSUED (required for projects 55,000 or greater per RCW 19.27.095) Name: \' -' ^ / - dV l� Address: City: State: Zip: Page 1 of4 BUILDING PERMIT INFORMATION - 206-431-3670 Valuation of Project (contractor's bid price): $ 1 1/ ter 000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): —Fen % M e ( e 0t,w,-1' ; 4 4‹..4- O r Sroa [.G re wl 004 1 - For "frU ` yo t� r -hk d .es -/or e 3 ��- c,��/ sal /-e Will there be new rack storage? ❑ Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (arca of the foundation of all structures, plus any decks over• 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Arca (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑' Automatic Fire Alarm 0 None ❑ Other (specify) Will ere be storage or use of flauumable, combustible or hazardous materials in the building? 0 Yes ❑ .......No If ""Yes', attach list of materials and storage locations on a separate 8-1/2" x I I" paper including quantities and Material Safety Data Sheets. Compact: Handicap: ❑ No If "yes", explain: SEPTIC SYSTEM 0 On-site Septic System - For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Appticationa Foruu-Applications Ou Line,20: 9 Applications Permit Application Revved - S3-1 t.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1'' Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport ^� Detached Carport Covered Deck Uncovered Deck. PLANNING DIVISION: Single family building footprint (arca of the foundation of all structures, plus any decks over• 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Arca (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑' Automatic Fire Alarm 0 None ❑ Other (specify) Will ere be storage or use of flauumable, combustible or hazardous materials in the building? 0 Yes ❑ .......No If ""Yes', attach list of materials and storage locations on a separate 8-1/2" x I I" paper including quantities and Material Safety Data Sheets. Compact: Handicap: ❑ No If "yes", explain: SEPTIC SYSTEM 0 On-site Septic System - For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Appticationa Foruu-Applications Ou Line,20: 9 Applications Permit Application Revved - S3-1 t.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFOIIATIO.N - 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Ttnkwila ❑ ...Water District 7125 ❑ ...Water Availability Provided Sewer District 0 ...Tukwila ❑ ...Sewer Use Certificate 0 .. Highline ❑ _Valley View ❑ .. Renton 0 ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Stonn Drainage) 0 ...Bond ❑ .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Constnnction/Excavation iFill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvemnents ❑ ...Traffic Control 0 ...Backflow Prevention - Fire Protection Ingation Domestic Water ❑ .. Geotecluical Report ❑ .. Maintenance Agreement(s) 0 ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) 0 .. Right-of-way Use - Profit for less than 72 hours 0 .. Right-of-way Use —Potential Disturbance 0 .. Work in Flood Zone 0 .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut 0 .. Pavement Cut ❑ .. Looped Fire Line ❑ ...Permanent Water Meter Size... WO # ❑ ...Tentporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ...Sewer Main. Extension Public 0 Private 0 0 ...Water Main Extension Public ❑ Private ❑ 0 .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounds ng ❑...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer Monthly Service Billing to: Name: 0 ...Sewage Treatment Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:'.4ppticationz Foran -Applications Ou Lme:20:1 Applicatioa::Permit Application Revised - S -9-t t.dcrs rtevised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — 41 Value of Construction — In all cases. a value of construction amoimt should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with curent fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 UTHO 4 AGENT: Signature: Y V 1., Date: /1-10-- Print 1'fo'Print Natne: �y % Mailing Address: 5500 `� �7 ' sw gre L-Fi( L1 ! e 1 qq 3304, s2City State Zip /11 '7 it/r- Day Telephone: 75 3 Z/ 1-7 38 2 H: Opp[icatien; Forrm-Applications Ou Lme20's i AppluatioesJ'ermit Application P.n rsea - &.9-11.docc Ketised: August 2011 bil Page 4 of 4 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 7888920020 Permit Number: D13-113 Address: 17250 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 04/10/2013 Applicant: BLACK BEAR YOGURT Issue Date: Receipt No.: R13-01280 Payment Amount: $2,977.64 Initials: WER Payment Date: 04/10/2013 01:38 PM User ID: 1165 Balance: $0.00 Payee: BLACK BEAR YOGURT TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3117 2,977.64 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $2,977.64 1,801.90 1,171.24 4.50 PrintPd• na1n-7n1s INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 *, (206) 431-367 Permit Inspection Request Line (206) 431-2451 )13 r3 P� ct:k_ kC. ci tny�`J C� Li A Type of i Aapectiotl;_, o p (A._ Address:Date I r72S/0 � f4`'i4 Called: 4 c N. 1 n v4 f N;T\ Special Instructions: _ r , Date Wanted:' G .7 a.m� p.m. Requester: onf P-2- �' .Z2y2-= 7 ElApproved per applicable codes. a Corrections required prior to approval. COMMENTS: p (A._ 4 c N. 1 n v4 f N;T\ k -- i l e II) ioec`A 7. v (T.) A Ins Date(1 (3 n REINSPECTION FEE EQIJIRED. rior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2009 Washin • ton State Ener Code Com liance Form for Nonresidential and Multifamil Residential glhltin�g, Motor, and Transformer P.e,rm=it Plans C,hec,list LTG -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project AddressSouth Center Square Shopping Center Date 1/24/2013 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2009 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Requires Location on Plans Building Department Notes LIGHTING CONTROLS (Section 151 Yes 1513.1 Local controVaccess Schedule with type, indicate locations A1.5 Yes 1513.2 Area controls Maximum limit per switch A1.5 Yes 1513.3 Daylight zone control Schedule with type and features, indicate locations A1.5 Yes vertical glazing Indicate vertical glazing on plans A1.1 Storefront N.A. overhead glazing Indicate overhead glazing on plans N.A. 1513.4 Display/exhib/special Indicate separate controls N.A. 1513.5 Exterior shut-off Schedule with type and features, indicate location N.A. (a) timer w/backup Indicate location N.A. (b) photocell. Indicate location N.A. 1513.6 Inter. auto shut-off Indicate location Yes 1513.6.1 (a) occup. sensors Schedule with type and locations A1.5 N.A. 1513.6.2 (b) auto. switches Schedule with type and features (back-up, override capability); Indicate size of zone on plans N.A. 1513.7 Hotel/motel controls Indicate location of room master controls Yes 1513.8 Commissioning Indicate requirements for lighting controls commissioning A1.5 EXIT SIGNS (Section 1514) Yes 1514 Max. watts Indicate watts for each exit sign LIGHTING POWER ALLOWANCE (Section 1530-1532) Yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps, ballasts, watts per fixture A0.2 N.A. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture RflOTORS (Section 1511) N.A. 1511 Elec motor efficiency MECH-MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERS (Section 1540) N.A. 1540 Transformers Indicate size and efficiency If "no" is circled for any question, provide explanation: CO PU PcDguN loo REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER 2009 Washin ton State Ener Code Com•Iiance Form for Nonresidential and Multifamil Residential Interior Lighting Summary 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential LTG -INT Revised December 2010 Project Info Project Address south center square shopping center Date 1/24/2013 17200 South Center Parkway suite 148 For Building Department Use Tukwila, WA 9818B Applicant Name: tach Miller / slack Bear Yogurt ApplicantAddress: 5700 100th Street SW Suite 330-152 Lakewood 98499 Applicant Phone: 253-212-7882 Project Description T2 Accent • New Building • Addition n Alteration IN Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive • Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 4 not changed • No changes are being made to the lighting and space use • Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plaNroom #) Occupancy Description Allowed Watts per ft2*" gross intenor Area in ft2 Allowed x Area Restaurant Black Bear Yogurt 1.20 2615 3138 T2 Accent Decorative pendants on track 2 50 100 L4 Seating LITESUP 9200 series (drum shape) pendants (group of 3) 4 105 420 **From Table 15-1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watts l 3138 Location (floor plan/room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed T1 Track Gimbal mounted LED track lighting 21 12 252 T2 Accent Decorative pendants on track 2 50 100 L4 Seating LITESUP 9200 series (drum shape) pendants (group of 3) 4 105 420 AC1 Feature Reproduction Antler Chandelier 1 320 320 Ll Pendant Drop Pendants 30 13 390 x L5 6" Recessed can lights 27 26 702 Exit Signa Self Illuminating LED Exit signs 3 5 15 T8 2x4 Recessed grid troffer 6 64 384 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts) 2583 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2009 Washin ton State Ener Code Com•Iiance Form for Nonresidential and Multifamil Residential 'I'nterior Lighting Summary (back) LTG -INT: 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Prescriptive Spaces Occupancy: Q Warehouse or Parking Garage t Other Qualification Checklist Note: If occupancy type is "other and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.85 g6 Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T-1, T-2, T-4, T-5, T-8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw-in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <=150w c) electronic ballasts 3. LED lights. -1 Unit Licltting Power Allowance (LPA Use" LPA2 (Wlft2) Uses LPAZ (w/ftx) Automotive facility 0.85 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1-3 Occupancies 0.90 Cafeterias, fast food establishments5, restaurants/bars5 1.20 Police and fire stations 0.90 Dormitory 1 0.85 Post office 1.00 Dweling Units 1.00 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1-1 and 1-2 Occupandes 1.20 Transportation 0.80 Hotel/motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classed "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries5 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies° (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15-1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w/ft2 may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three -quarter -height partitions (transparent or opaque) and lighting for free-standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of furniture, dothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories!, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling -mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be tumed off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. 2009 Washin•ton State Energ Code Compliance Form for., Nonresidential and Multifamil Residential Project Summary PRJ-SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address South Center Square Shopping Center Date 1/24/2013 17200 South Center Parkway suite 148 For Building Department Use Tukwila, WA 98188 Applicant Name: Zach Miller / Black Bear Yogurt Applicant Address: 5700 100th Street SW Suite 330-152 Lakewood 98499 Applicant Phone: 253-212-7882 COUGHL1 PORTERLUNDEEN STRUCTURAL • CIVIL • SEISMIC ENGINEERING FILE COPY Structural Calculations for the Black Bear Yogurt Mezzanine South Center Square DSDAA January 2, 2013 S-122050-01 Prepared by: Eric Dixon Angelia Tanamal p 13- l►3 REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER Conterminous 48 States 2009 International Building Code Latitude = 47.455200000000005 Longitude = -122.25681000000002 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 1.420 (Ss, Site Class B) 1.0 0.486 (S1, Site Class B) Conterminous 48 States 2009 International Building Code Latitude = 47.455200000000005 Longitude = -122.25681000000002 Spectral Response Accelerations SMs and SM1 SMs= Fa xSsand SM1 = FvxS1 Site Class D- Fa = 1.0 ,Fv = 1.514 Period Sa (sec) (g) 0.2 1.420 (SMs, Site Class D) 1.0 0.735 (SM1, Site Class D) Conterminous 48 States 2009 International Building Code Latitude = 47.455200000000005 Longitude = -122.25681000000002 Design Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 =2/3xSM1 Site Class D = 1.0 ,Fv = 1.514 Period Sa (sec) ' (g)::. X0.2 0.946 (SDs, Site Class D) 1.0 .0.490 (SD1, Site Class D) '::1 D.AC'. tLA) Ai q � 117- /7°12- ASC.- rc - 05 Cao. Pte14. t COUGHLINPORTERLUNDEEN STRUCTURAL • CIVIL • SEISMIC ENGINEERING Tabte 13. 5 - 1 See'. 13.1. 3 froMin9 -- 13L e 27c T G 51 eek .Iv6e1 Shea-Wrg - 3411 Pt, wax) Ce:�t�ry� - (1) tot r.s '% 61,0 sprin Were 4 M'c 1+2 2P 0.4-0- (.0 x 0. 946 s Fp.M = Sos 0,94 2.5 PSf 2.0 P 2.5 P 5.4 psi --�=Slxf 16.1 Os f n 13.31'5' ic 2.2.5 0.3 Sipe, Tp k/3p 0.3 Y 0. 946 (.0 1,1J13 x 0. 2.`b4 1J r Fp, rnax I.G COS Tp c (. , t 0.14G f r.0 �� I.51 4 W p 0."S J4, 3.�k r c 4.S5k Project: P,LACIc +- A Project No. Client: Designed By: i Checked By: Date: It 29(.7ot, Sheet 2- of 413 PINE STREET • SUITE 300 • SEATTLE, WA 98101 • P: 206/343-0460 • F: 206/343-5691 COUGHLINPORTERLUNDEEN -- STRUCTURAL • CIVIL • SEISMIC ENGINEERING P-tSA- 3D n- z 22! COLO MN HSS 6 x- 6 x ''/8 0. 36 2- OS" 1 . 651 r EAM t-tSS ' %). G My O. 23 0,13" Project: fix. A t c - Project No. K 3}. CTU(cW1(-A) Client: Designed By: Ai Checked By: Date: tt /-)-3 /2.0 Sheet of 413 PINE STREET • SUITE 300 • SEATTLE, WA 98101 • P: 206/343-0460 • F: 206/343-5691 rf *cis c RedSpecTm by RedBuiItTM v7.0.16 Project: Project Location: Black Bear Mezzanine (Tukwila) Folder: Folder Date: 12/14/12 11:11 AM Designer: AT Comment: Type: Type 11.875" Red-I90TM @ 16" o.c. This product meets or exceeds the set design controls for the application and Toads listed DESIGN CONTROLS % Allow. Design Allow. DOL - Control Pass/Fail Shear (Ib) 36% 819 2255 100% - All Loads PASS Positive Moment (ft -Ib) 29% 2764 9605 100% - All Loads PASS DEFLECTIONS (in) % Allow. Design Allow. Design Allow. Pass/Fail Span Live 86% 0.155 0.180 L / 999+ L / 900 PASS Span Total 28% 0.189 0.675 L /:859 L / 240 PASS FloorChoiceTM Rating: 9.4 Performance rating is based on: 24 oc (23/32", 3/4") sheathing, nailed only, 5/8" Gypsum ceiling, simple span, Flexible support. RedSpec has not performed a structural analysis of the sheathing. SUPPORTS Support 1 Support 2 Live Reaction, Critical (Ib) (DOL%) 675 (100) 675 (100) Dead Reaction (Ib) 144 144 Total Reaction (Ib) (DOL%) 819 (100) 819 (100) Bearing Flush Flush Support Beam Beam Req'd Bearing, No Stiffeners (in) 1.75 1.75 Req'd Bearing, Stiffeners (in) - HANGERS Model Left None Selected Right None Selected Top Face Member Header Size SPANS AND LOADS Dimensions represent horizontal design spans. A 13'- 6.0" APPLICATION LOADS Type Units DOL Live Dead Partition Uniform psf Floor(100%) 75 16 0 Tributary Member Type 16" Floor .Joist NOTES • Building code: IBC. Methodology: •Allowable Stress Design • Continuous lateral support required at top edge. Lateral support at bottom edge shall be per RedBuilt recommendations. C:\Users\AT\Documents\RedSpec\Black Bear Tukwila.red Page 1 of 1 The products noted are intended for interior, untreated, non -corrosive applications with normal temperatures and dry conditions of use, and must be installed in accordance with local building code requirements and RedBuilt'" recommendations. The loads, spans, and spacing have been provided by others and must be approved for the specific application by the design professional for the project. Unless otherwise noted, this output has not been reviewed by a RedBuilt'" associate. PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. RedBuilt'", RedSpec'" Red -IT", Red -I45'", Red -I65"", Red-I65T'", Red-I90TM, Red-I90HTM, Red-19OHSTM, Red -L'", Red -LT'", Red-WTM, Red -S'", Red -MTM, Red -HT", RedLamT", FloorChoicee" are trademarks of RedBuilt LLC, Boise ID, USA. Copyright © 2010-2012 RedBuilt LLC. All rights reserved. COUGHLINPORTERLUNDEEN STRUCTURAL • CIVIL • SEISMIC ENGINEERING 1j\Cbnf.K.,4On Za 'k - f+ C zo 1:717 ) 3o k A)Tn = 0.9 x V X 36 ks; _ 18.614 DCR _ 0,6 2 G 1.00 OK t" weld 54" pn 3/5„ tt- 01S X O.60 . 31) ksi x DGR = O. 6o < 1.00 a weld3. _/rb 0 j6&4x 3/`b' ,c ( A" Y. 3 O 4>Rn 4> ( 0.4,5 ) 0.9.5 x (0.85-a 0.6 53,5k < 3o k DGR- = O, 56 < 1.00 OK t. weld 3irc, ;on HSS COLUMN) 4, 4.6x.4 OGS = 0_12 < +.00 OK 3,46 3I rG� •> 30 k 50k > 3ok . 2. ÷- 1.6 X 0.6 n 1014.c1 x 3/rc.'r y< 4" ) .r 16,1 k ?? 2_14 - Project: '4` Project: 13.. ctom. 2. . CTut<w i L- A s) Project No. Client: Designed By: A7 Checked By: Date: 0 /2_012 Sheet 5- of 413 PINE STREET • SUITE 300 • SEATTLE, WA 98101 • P: 206/343-0460 • F: 206/343-5691 F-00-riNC"1 DEsIGs COUGHLINPORTERLUNDEEN STRUCTURAL • CIVIL • SEISMIC ENGINEERING PovFt Pp &kW 61 Po _ 16.1 pS f K t t, 2h' n 13.395' = 2. 5 k 1 3,614 + 1.4k + .3 k 9.2. k Ill r+.9 $10Cj 501( Pt. Io0 Ps.f x I1.? -5',e 13.3-5' 15 k J P5. 2- lc. Sc?._ \ C£ ( FOX Qo,howabke i Ut..-T1\MATE ( FOP- Vu ;Pt) t P. 24.2 k governs 1.2 0 + 1_k> L = 29-k Po t o� P� io.6 k 1.2 D + i.o - +- L - 20.^olc. Po i- O.15 v 0.1 Pt. t- 0.9zj I?� = 2.1 ..5 k .4— scwerriS Project: BLACK C7Ut_Wl1.--A) Project No. Client: Designed By: Ar Checked By: Date: 12 j o7 -12o t 2 Sheet G of 413 PINE STREET • SUITE 300 • SEATTLE, WA 98101 • P: 206/343-0460 • F: 206/343-5691 Eccentric Footing For Gravity Loading Project: Black Bear Mezzanine (Tukwila) Label: Column Footing (GEOMETRY DATA COLUMN WIDTH b= COLUMN DEPTH c = FOOTING WIDTH B = FOOTING LENGTH L = FOOTING THICKNESS t = LOAD ECCENTRICITY e = TOPPING SLAB THICKNESS tslab= SOIL OVERBURDEN tsoil = (LOADING (SERVICE) DL = LL = CRITERIA Pc = ALLOWABLE SOIL PRESSURI 0= SOIL WEIGHT W= Results Footing = slab = Soil = Force Resultant = Moment about CL = Calculated e = U6 = CHECK TRIANGLUAR LOAD DIS. 6 8 6 3 12 1 6 6 2.5 15 4 4.00 110 2.7 1.3 1.0 22.51 17.5 0.78 0.50 in in feet feet in ft in in Kip Kip (LL=100psf) ksi ksf pct kip kip kip kip kip -ft ft feet TRIANGULAR SOIL PRESSURE (e>U6) a= 3a = Putt = Psoil = Fr ult= 0.7 feet 2.2 feet 1.5 Litt Factor 3.5 33.0 ksf DCR = fig kips 0 f. -Q% TWO - WAY Punching Vu = 27.0 kip fVc = 66.1 kip DCR = ONE - WAY SHEAR Vu = 1.8 kip/ft fVc = 9.7 kip/ft DCR = 9! talab tsoil P CL �e a t L COUGHLINPORTERLUNDEEN STRUCTURAL • CIVIL • SEISMIC ENGINEERING x 1' - o" dP, FOO TA 1,3 G _ It.6 154_ lc I ;4633 ks f /., _f _I. nn P '33^ 3-0' Mu= 1.633ksfx.b' (2;2.5' )1 2 Mu G 4 Mn 2$ -_.�-k .G As ;5‘.':‘ OSS fps gtc.; co- 0.00Pb b .K \ = .wSIC D1iX R -1 re' 5" @ 1 floc As 1.4 6-5 t, 1-1 u I.2." 3 y4 3 x (2.15 V- 2 I k - As ? 0.56 \,..2'• 0.00 t8 _ 0.0016r 's6'; 12. ` 0.1s ;na. } 5 0 at, As. o. 93 3 #5's Project: 1'51- Au_ P),t;Fte- Mc g. C-11) MLA-) Project No. Client: Designed By: AT Checked By: Date: 12 ] IZ.t 2012 Sheet a of 413 PINE STREET • SUITE 300 • SEATTLE, WA 98101 • P: 206/343-0460• F: 206/343-5691 Anchoring to Concrete: (ACI 318-08 Appendix D) Input cells = General Anchor Type Connection Designed For Seismic Loading Cracked or Untracked Concrete Condition A or13 Built Up Grout Pad Supplementary Edge Reinforcing Load eccentricity, e'N, = Load eccentricity, e'N2 = Load eccentricity, eV = N. = V. = Overstrength Factor =no= Steel J -Bolt Yes (0.3.3.1-5) Cracked B (D.4.4) Yes (D.6.1.3) No Edge Reinforcing 0in -1.25 in 0 in 2.00 kips 2.00 kips 1:00 (0.3.3.6) faa= Stud Diameter, d, = en= Embedment, he = Number of Anchors, n = Bearing Area, Ab = Concrete 58 ksi 3/4 in 2 In 5 In 4 0.785'inA2 t'c= Member Thickness. h = Front edge distance, Ca, = Side edge distance, C.2= Group spacing parallel to Loaded edge, Si = Group spacing parallel to side edge, S2 Spacing & Edge Distance Reference Data 4000 psi 12 in 4 in 31.5 in 9 in 4.5 in Cm. Cn; = So = Distance to Back Row (Loaded Edge Loaded) = Distance to Back Row (Side Edge Loaded) _ Smin = Smax = 31.5 4[oK 1(0.8.2-3) 9 8.5 40.5 4.5[OT j(D.8.1) 9i0K (D.6.2.7) 25 20 - 5 0 0 • • V • • 10 15 20 25 Loaded Edge 30 35 40 45 Vu S2 is v 1 O S1 Ca2 Anchoring to Concrete: Tension (ACI 318-08 Appendix D) General Anchor Type J -Boll Connection Designed For Seismic Loading Yes (0.3.3.1.5) Cracked or Untracked Concrete Cracked Condition A or 6 B (0.4.4) Load eccentricity, e'5, = 0 In Load eccentricity, e'a2 = -1.25 in N., = 2 kips Steel = 58 ksi Stud Diameter, d, = 3/4 in Embedment, ha= 5 in Number of Anchors, n = 4 Bearing Area, A.,. = 0.785 1n^2 Concrete rc = Member Thickness, h = Front edge distance, C., _ Side edge distance, C.2 = Group spacing parallel to loaded edge. S, = Group spacing parallel to side edge, S2= Steel Tensile Strength: (D.8.1) 4000 psi 12 in 4 in 31.5 in 9 In 4.5 in 4= n"A..'f,.,= N„ _ $•N.. _ Concrete Breakout Strength: (0.5.2) 0.75 (ductile steel element assumed) 0.334 in^2 77.49 kips (0-3) kips 58.12 = 9•h.t 2 = A,a.. _ Ant = eccentricity factor, P..N = edge distance factor, wwN = cracked concrete factor, 4'.N = k= k'sgd(rc)'h.t1.5 = N.= 16'sgn(fc)'h„^(5/3) = N. Aw Aw=•ww.u* Test w.N N. = N,,, = (0.75)14•N... _ (0.75)•b'N,../(Omega Factor) = Controlling 414,..= Anchor Pullout Strength: (D.5.3) 0.70 (D.4.4) 225 in^2 (0.6) 384 in^2 1.00 (D-9) 0.860 (D-10/11) 1.00 (D.5.2.6) 24 (0.5.2.2) 16.97 kips (0-7) 14.79 kips (0.8) 24.91 kips (0-5) 13.08 kips 5.23 kips kips 5.23 cracked concrete factor, w.r = Awe= en= 0.9'fc'e0 d. or e'A.,."fc = NP = n•w.r N,, = N... (0.75) 4'N... = (0.75)14•N.../(Omega Factor) = Controlling $•Nero Side Face Blowout: (0.5.4) 0.70 (D.4.4) 1.0 0.785 in^2 2.0 in 5.40 kips (0.15/16) 21.60 kips (0.14) 11.34 kips 4.54 kips kips 4.54 Side Face Blowout Req'd7 < 3•C,.:,7 160'C..„A.,. 0.5'fc^0.5 = (1+sj6'c.rJ•N.. = N,. _ (0.75)'$'N..= (0.75)'b"N../(Omega Factor) _ Controlling b'N.. _ (0.75)•b•N... _ (0.75)'4•N.../(Omega Factor) Controlling b•N... Tension Capacity Shear Capacity Interaction Check Check Not Required 0.70 (0.4.4) No 35.86 kips (D-17) 49,31 kips (D-18) 18.83 kips 7.53 kips kips 25.89 kips 10.36 kips kips NA NA b•N. _ • $•N.= 4.54 kips 0.44 $Vn= • $ry.= 5.36 0.43 kips DCR Note that factor of 0.4 per 0.3.3.6 has been applied 25 20 m 15 P w ' 10 5 0 0 10 20 30 Loaded Edge • • • 0 • 40 (0 Anchoring to Concrete: Shear (ACI 318-08 Appendix D) General Anchor Type J -Bolt Connection Designed For Seismic Loading Yes Cracked or Uncracked Concrete Cracked Condition A or B Built Up Grout Pad Yes (0.8.1.3) Supplementary Edge Reinforcing N0 Edge Reinforcing Load eccentricity, ay. = 0 in VW = 2 kips Steel Stud Diameter, d. = Embedment, he= Number of Anchors, n = Concrete 58 km 3/4 in 5 in 4 fc = 4000 psi Member Thickness, h = 12 in Front edge distance, C. = 4 in Side edge distance, C.1= 31.5 in Group spacing parallel to loaded edge, S, = 9 in Group spacing parallel to side edge, Sr = 45 In Steel Shear Strength: (0.8.1) = Ase= n'0.814..'F,., or n'A..'f,a = V„ = 4'V.= 0.65 (ductile steel element assumed) 0.334 fa^2 48.49 Nps (0-19/20) 24.161kIpe Concrete Breakout Strength Towards Loaded Edge - Back Row: (0.8.2) = 0.70 (0.4.4) 4.5•C.,02=Ar,= 325.125 in02 (D-23) A = 414 in^2 eccentricity factor.')'..,v edge distance factor, 'Y,gv = cracked concrete factor, ill, = member thickness factor, or = Anchor bearing length, I. (8 or 7)1(Udoyo.2'sgn(dolcrc141.5 = Vs = (0.75)•4' 14s (0.75)'4'Vdf(Omega Factor) _ Controlling f -V. , 1.00 (0.26) 1.00 (0.27/28) 1.4 (06.2.7) 1.0 (0-29) 5.0 In (0.0.2.2) 13.89 kips (0-24/25) 25.52 kips (0.22) 13.40 kips 5.36 kips kips 5.361 Concrete Breakout Strength Towards Side Edge - Front Row: (D.6.2) 4= 0.70 (04.4) 4.51C.02 = A,. = 4485 in^2 (0-23) A. = 689 in^2 eccentricity tactor, Y'«.v= 1.00 (0-28) edge distance factor, 'l'.y,= 1,00 )0.8.2.1c) cracked concrete factor.'t'v = 1.4 (D6.2.7) member thl0tness factor.'p,v= 2.0 (D-29) Anchor bearing length, I. = 5.0 in (0.6.2.2) (8 or 7)'(Udo)M.2•sgrydoNc)•c1^1.5 = Vs= 99.06 kips (D-2405) 2'A.,/A„"t'...v"I'.ov")'av"I'^v'Vo = V, c. 82.46 kips (0-22) (0.75)•$ 044 43.29 kips (0.75)'41V..d(Omega Factor) = 17.32 Nps Controlling 4'V..s .1 43.2811dpa Anchor Pryout Strength: (0.6.3) = krs= = k.r Nrsr = Vwa = (0.75)•$ V.. (0.75)•41V../(0mega Factor) _ Controlling 4'v., = Shear Capacity Frond Row (5015 Ioad) 0.70 (0.4.4) 2.0 24.91 kips (0-5) 49.82 Nps (D-30) 28.15 kips 10,46 kips kips ( 26.151 4'V, 0.5'V.. / 4'V. Tension Capacity 2.31kips 0.43 NW 14'N,.. Interaction Check 4.54Nps 0.44 OCR *1 Note that Castor of 0,4 per 0,3.3.6 has been applied 0.844* 25 20 8 15 'a 10 • • • • • 0 5 10 15 20 25 Loaded Edge Concrete Breakout Strength Towards Loaded Edge - From Row: (0.6.2) 4= 0.70 10.4.41 4.51C,02 = A,,. = 72 in02 (0-23) A. = 126 in^2 eccentricity factor, 'P.ry = edge distance tactor, W,s,v = cracked concrete tactor.'(' ,v = member thickness factor, 'F,v Anchor bearing length, I, 71(Udo)^0.21sgrt(do•rc)•c1^1.5 = V, _ Aq/4.."114e.v"744.4"74v'Y',v'Ve a Vw (0.75)^4'V.p a (0.75)141V.,./(0maga Factor) _ Controlling 4=V.. = Shear Capacity Bock Row or Parallel (10016 Toad) 1.00 1.00 1.4 1.0 5.0 In 4.48 kips 10.98 kips 5.77 kips 2.31 kips kips 2.311 4•v, - • 5.36 kips 0.37 35 (0-28) (0.2708) (06.2.7) (0.28) (D.0.2.2) (0-2405) (0.22) 40 45 Controlling Shear OCR Vw/4'V,Max al 0.431 11 STA \ R.. 5UPP ) aT MST AL. S VOS COUGHLINPORTERLUNDEEN STRUCTURAL • CIVIL • SEISMIC ENGINEERING DL = 30 PS.f L L = too pc -E Tp.,b = 3'- 3" Pu : C1.2 Dt k x I /O° ac. _ 4.33 f' -6 L) x Ta','b . $50 Ia I.-ergth L 4' - 3" SVAva, P-P‘LA1v16 = Zj A"x6)3!(6(LV) r� „co lb ,c 3 5' x.17" 2, 5" z N-01.15 PL3 _ Q2k v (3.6' )3 _ 0.32 3 E T 3 )`. nom 1(...s1 x 0.$41 ; r` 2 4 2`)` 2."x 1h 1620 Ib 'roject: 5L -A( \A >k: 1 ate. =2 _T) —1/,) ) 'roject No. Designed B : Date: 12. 2012 Client: Checked By: Sheet (2 of 413 PINE STREET • SUITE 300 • SEATTLE, WA 98101 • P: 206/343-0460 • F: 206/343-5691 r- 2007 NASPEC Project: Black Bear Mezzanine (Tukwila) Date: 1/2/2013 Model: Stair 1'r R1 R2 4.25 ft @ oc Section : 350S137-33 Single C Stud (X -X Axis) Fy = 33.0 ksi Maxo = 367.7 Ft -Lb Moment of Inertia, I = 0.441 in"4 Va = 1023.6 Ib Loads have not been modified for strength checks Loads have been multiplied by 0.70 for deflection calculations Flexural and Deflection Check Mmax Mmax/ Mpos Bracing Ma(Brc) Mpos/ Deflection Span Ft -Lb Maxo Ft -Lb (in) Ft -Lb Ma(Brc) (in) Ratio Center Span 0.0 0.000 0.0 Full 367.7 0.000 0.000 U0 Distortional Buckling Check K -phi Lm Brac Ma -d Mmax/ Span Ib-in/in (in) Ft -Lb Ma -d Center Span 0.00 51.0 378.7 0.000 Combined Bending and Web Crippling Reaction or Load Brng Pa Pn Mmax Intr. Stiffen Pt Load P(Ib) (in) (Ib) (Ib) (Ft -Lb) Value Req'd ? R1 0.0 1.00 165.9 290.4 0.0 0.00 No R2 0.0 1.00 165.9 290.4 0.0 0.00 No Combined Bending and Shear Reaction or Vmax Mmax Va Intr. Intr. Pt Load (Ib) (Ft -Lb) Factor VNa M/Ma Unstiffen Stiffen R1 0.0 0.0 1.00 0.00 0.00 0.00 NA R2 0.0 0.0 1.00 0.00 0.00 0:00 NA Combined Bending and Axial Load Axial Ld Bracing (in) Max K -phi Lm Brac Allow Ld Intr. Span (Ib) KyLy KtLt KUr (in-Ib/in) (in) (Ib) P/Pa Value Center Span 850.0 (c) None None 101 0.0 51.0 1688.8 (c) 0.50 0.50 FILE COPY rimos...ts I r, BLACK BEAR YOGURT Specification Booklet for Southcenter Location of: Black Bear Yogurt Shop and Espresso, A Retail Beverage & Coffee House 17200 SouthCenter Parkway Suite 148 Tukwila, WA 98188-3301 Kitchen, Prep., Foodservice & Beverage Equipment Prepared for Jesse Roberge & Zach Miller D13- h3 REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER DISPENSE -RITE ITEM 1 1 r; -\\.J J /7, _[7.-11 FFS-A__ , moa TAYLOR® GRW11 SERIES TOTALLY DIFFERENT. Shown with optional ADA cart. LISTED Standard 6 SA2650 u° CE Selected So Hz. Models \natal Item No. _ ITEM 2 C723 ADA Soft Serve Freezer Twin Twist Features Offer all the popular soft serve variations from low or non- fat ice creams to custards, yogurt and sorbet. Serve two separate soft serve flavors, or an equal combination of both in a twist. Freezing Cylinder Two, 2.8 quart (2.7 liter). Mix Hopper Two, 14 quart (13.2 liter). Separate hopper refrigeration (SHR) maintains mix below 41°F (5°C) during Auto and Standby modes. Indicator Lights Digital readout displays hours since last brush cleaning to assure product safety. Mix Low light alerts operator to add mix. Audible alarm may be enabled to sound when mix is low. When the Mix Out light flashes, the unit shuts down automatically to prevent damage. Touch Screen Controls Microprocessor touch controls are embedded in durable tempered glass panel. Multiple languages are selectable. Viscosity is continually measured to dispense consistent quality soft serve desserts. Temperatures in the hoppers or freezing cylinders may be displayed at any point of operation, in either Fahrenheit or Celsius. Draw counter allows operator to view number of servings dispensed. Standby During long no -use periods, the standby feature maintains safe product temperatures in the mix hopper and freezing cylinder. Door Interlock System Protects the operator from injury as the beater will not operate without the dispensing door in place. Freezer Door A specially designed thermo-plastic door allows quick ejection of product with a simple movement of the draw handle. Self closing draw handles are standard. Shown with optional top air Meets Americans with Disabilites Act (ADA) dispensing height for self discharge chute. service application Rockton, Illinois 61072 800-255-0626 Phone 815-624-8333 Fax 815-624-8000 www.taylor-company.com e-mail: info@taylor-company.com International Office Taylor Company S.r.l. Roma, Italy Tel: +39-06-420-12002 Fax: +39-06-420-12034 e-mail: romeoff©taylor-company.com ISO 9001:2000 Registered Firm C723 ADA Soft Serve Freezep WAWAIN DIr14G WATER OUT (vrNm REAR NEW /LEFT MOS (WATERODOM, 37.93 [963.4] 33.78 [858.1] I 36.24 [920.6] 1 34.21 [868.9] 382 4800 [97.0] [1219.2] 19.12 [485.7[ 21.11 15.12 (536.1] [384.1] I, 20.47 [519.8] 4.00 (101.8] 26.79 [680.8] 32.23 [818.6] 1 55 37 [1406.3] Shown with optional Air Discharge Chute and ADA Cart 26 91 (683.5) 23.31 (592.1] r 18.87 i 57 32 [1455.9] [479.3] 39 93 [1014.3] Weights lbs. cgs. Net 500 226.8 Crated 559 253.6 cu. ft. cu. m. Volume 39.2 1.11 Dimensions in. mm. Width 23-5/16 592.1 Depth 33-13/16 858.1 Height 36-1/4 920.6 Counter Clearance 'Designed to rest on a plastic pad directly on counter top or optional cart. Electrical Maximum Minimum Poles (P) Fuse Size Circuit Ampacity Wires (W) 208-230/60/1 Air 40 29 2P 3W 208-230/60/1 Water 40 29 2P 3W 208-230/60/3 Air 25 18 3P 4W 208-230/60/3 Water 25 18 3P 4W 220-240/50/1 Air 30 24 2P 3W 380-415/50/3N- Air 12 9 4P 5W This unit may be manufactured in other electrical characteristics. Refer to the local Taylor Distributor for availability. (For exact electrical information, always refer to the data label of the unit.) Continuing research results In steady Improvements; therefore, these specifications are subject to change without notice. Biddin! Specs Electrical: Volt Hz ph Neutral: Yes ❑No Cooling: ❑Air ❑Water ENA Options: 18.62 [472.9] 23.25 (590.5] Specifications Electrical One dedicated electrical connections is required. See the Electrical chart for the proper electrical requirements. Manufactured to be permanently connected. Consult your local Taylor distributor for cord & receptacle specifications as local codes allow. Beater Motor Two, 1.0 HP. Refrigeration System One, 9,500 BTU/hr. R404A. Separate Hopper Refrigeration (SHR), One, 400 BTU/hr. R134a. (BTUs may vary depending on compressor used.) Air Cooled Minimum 3" (76 mm) around all sides. Minimum air clearances must be met to assure adequate air flow for optimum performance. Optional air discharge chute directs heated air exhaust upwards. No clearance required on right side if air discharge chute is used. Water Cooled Water inlet and drain connections out rear panel 3/8" FPT. ®p1t onS • Standard Cart with casters and a door (see C723 spec. sheet) Net Weight: 74 lbs. (33.6 kg) Crated Weight: 95 lbs. (43.1 kg) • ADA Cart with casters - recommended for self service to meet ADA compliant dispensing height - no door (shown) net Weight: 74 lbs. (33.6 kg) Crated Weight: 87 lbs. (39.5 kg) • Drain Adaptor (for ease of rinsing & cleaning) • Draw handles to comply with ADA force requirement • Draw Valve Lock Kit • Hopper Locks • Hopper Agitators • Legs - [increase height of unit by 4-1/4" (108 mm)] • Decals - Twist or Flavor Burst Cone • Top Air Discharge OPTIONAL AIR OUT STANDARD AIR OUT FIGURES IN BRACKETS INDICATE MILLIMETERS. DECIMAL DIMENSIONS EQUAL TO PLUS OR MINUS N18 YM (1.P ,L 1=1 o°e oa TAYLOR® Taylor Company, Rockton, Illinois 61072 815-624-8333 800-255-0626 Fax 815-624-8000 www.taylor-company.com 069352 -ADA 5/12 •s 4,%.* • . ..-... •ggia.. . ._,-----,_,-••..•;, • ...:c:.'_.•• •_-, ,•,e7-•,_,,0• ,••s:,7""-..-!.'4I4,-'r,.:.a1- A. ., ola,i0f1L _P4girL1r1.o1._1v.•g•_•r4-"•-,-eEi„x:3t„stlg, r4smfa-iot rroi-.s„.;7w.:: ..•:w7l;__....:.-....1.:..3, a. a '•7 - s qm-.T."-•'.,s.t^,s:.r0.g4r5::;."?,,.j • , - -, ,.--n. -1 spai,..-... e3.,•••i,„„40,,,‘,--„,,,,......,.__t.., ,..r, -....z 4,11r-,..frago E.- ags tw----tr wm " "Jo. beir lite• k*Wit- ---,-„,,i,.. * . ' -'- 7 " AlSr6".--_,•••4:." -- -00V -.. Se 4,7=',,,-"..w.- , .--...er ,'• ' • ' 4r.,..- ‘t• .0,„•• ,lialleg• 41Pre ._.............--.., - _. 00.1 .4.4))141 ;40..kfilohiji ' '. t-14... =+-- ......„.7---.111, - - • ...L;1.Z.‘..„Lpit - -,....X! CZ> '•••• -v., _,.....:.:: -.".r.11- ' i , 1 1 -Z?''' - t - '94 . ' .4-2-1M"Mtar,';'4"-.4Z"'j::1-- 4 --"' • ,.i.. - ..-7,,, -7----'"'-..6,,,, 1-7, r -i' --z,, -- ... The Luminary Series... where superior performance and unique versatility are showcased in an ultramodern design. A masterpiece on fire, but a presence that represents luxury, with or without the flame. Innovation on Fire LuLut,u.FM1PRODUCTS.com Sleek & Sophisticated Introducing the Luminary Series Linear Vent -Free Fireplace System, Paris Lights. These dynamic new p chic and polished style with adaptabil thought of, yet. Paris Lights fireplaces span 43" across. Reflective black porcelain lined interior walls amplify the flame and boast the power of the fire. The lively blaze is highlighted by a glowing tray of embers and is innovatively accented with hallogen lighting. Crystal clear glass stones add sparkle to the dazzling yellow flames and are elegantly illuminated as the lights shine through from underneath. Create ambiance with the mood f lighting,w hether the fire is burning or not. Thcutting edge linear design is far from traditional, yet all controls are concealed so the finished look remains clean and effortless. This standout series is beyond accommodating when it comes to application. r -Paris Lights Vent -Free fireplaces have the ability to transform to see-thru models with the LVSTI Vent -Free See-Thru Conversion Kit. Finish your Luminary right up to the edge or opt for one of our Decorative Face Trims, available in three colors. Paris Lights Features • Reflective Black Porcelain Uned Interior • Crystal Clear Glass Pebble Burner • Electronic Ignition with Adjustable Flame • Mood Lighting • Operates with Included Remote Control • Approved ANSI Z21.11.2 Paris Lights Accessories • Linear Vent -Free See-Thru Conversion Kit • Decorative Face Trim • Smooth Glass Pebbles In Four Colors You can easily convert your Linear Fireplace to a See-Thru model and enjoy the flame from two rooms at once! Be bold with one of our Decorative Face Trim Frames in aged silver, aged copper or black. Glass Pebbles available in Amber, Speckled Orange, Green and Blue. Paris Lights Vint -Free Linear Offering MODEL LVF43NR LVF43PR SIZE 43" 43" FUEL Natural Propane BTU's 39,000 37,000 FMI PRODUCTS, LLC www.FMIPRODUCTS.com For more information, call (866) 328-4537 © 2012 FMI PRODUCTS, LLC NFI NATIONAL FIREPLACE INsnTUTF PFS Tested & Certified t FA5520-0212 Product design, features and specifications are subject to change at any time. Refer to current product instructions prior to installation. Printed in U.S.A. T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 REG. #A2601 ISO #9001 Travelers Rest, SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax: 864-834-3518 www.tsbrass.com This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity Customer/Wholesaler Contractor Architect/Engineer 3/8" NPT Female Inlet (Left Side of Reel) Open Coated Hose Reel; 15 Ft. of 3/8" Hose 012" [304mm] Model No. B-7212-01 Item No. ITEM 5 14 3/8" [365mm] 7 3/16" [182mm] 15" [381 mm] EB -0107 5 1/2" [139mm 01/2" [13mm] 6 7/16" — 5 1/4" [164mm] [133mm] 3/4" [19mm] 2 3/8" [60mm] 1/2" [13mm] Product Specifications: Hose Reel System: 3/8" x 15 Ft. Open Coated Reel EB -0107 Blue Spray Valve Drawn JRM Checked DHL Approved JHB Scale: 1:8 Date: 10/26/07 Sheet: 1 of 2 T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 REG. #A2601 ISO #9001 Travelers Rest, SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax: 864-834-3518 www.tsbrass.com Model No. B-7212-01 Item No. NO. SALES NO. DESCRIPTION 1 EB -0107 Hi -Flow Blue Spray Valve 2 012504-40 Blue Handle Grip 3 014938-45 Roller Assembly Repair Kit 4 014949-45 Hose Stop Repair Kit 5 014944-45 3/8" x 15' Hose Replacement Kit 6 014932-45 Small Coated Spring Assembly 7 014946-45 3/8" Swivel Repair Kit 8 014948-45 0 -Ring Replacement Kit 9 014940-45 Ratchet Repair Kit Product Specifications: Hose Reel System: 3/8" x 15 Ft. Open Coated Reel EB -0107 Blue Spray Valve Drawn JRM Checked DHL Approved JHB Scale: 1:8 Date: 10/26/07 Sheet: 2 of 2 Model No. TICS BRASS AND BRONZE WORKS, INC. 2 SADDLEBACK COVE / P.O. BOX 1088 / TRAVELERS REST, SC 29690 PHONE 800-476-4103 FAX 803- 834-3518 REG.4IA2601 ISO 0002 0 R K 1 Item No.: Job Name: Architect/Engineer Approval: Notes: 3/8° NPT FEMALE OUTLET 1 8°S [3m&OUTLETm] OFFSET BETWEEN II II ._ • (113/8"] 05mm] WNWeirdiWs omairiim 4° C/C ' [102mm] 1 TOP VIEW REMOVABLE LOOSE KEY HANDLES (REPLACEABLE WITH CAPS) 1415] . 11\\'ILii. -- $�-- ----- ---� - [ 1/2° NPT SIDE VIEW FRONT VIEW FEMALE INLETS Product Description: MIXING CONTROL VALVE WITH LOOSE HANDLES, 1/2" NPT BOTTOM INLETS, AND 3/8" NPT TOP OUTLET Drawn: GEF Checked WJS Scale: 6"-1' Approved JHB Date: 03/15/07 ocu T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 REG. #A2601 ISO #9001 Travelers Rest, SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax: 864-834-3518 www.tsbrass.com Model No. ORK-SK Item No. This Space for Architect/Engineer Approval Job Name Date Model Specified Customer/Wholesaler Contractor Quantity Architect/Engineer B-0963 Continuous Pressure Type Vacuum Breaker HW -2B-36 3/8 NPT x 36" Flex Water Hose w/ AW -5B Quick Disconnect 3/8" x 18" Riser 002535-25 3/8 NPT Male Close Nipple 062A Adapter (Sold Separately): 1/2 NPT Male x 3/8 NPT Male --aP7A❑�1, 2 1/4" [57mm] 11C'1 A1,1, I.0 B-0109-01 6" Wall Bracket Cut to Size in Field 23 5/8" [600mm] Swivel Elbow Assembly w/ 1/2 NPT Female Inlet & Easylnstall Feature Outlet Product Specifications: 1/2 NPT Inlet Elbow, 3/8" x 18" Riser, Vacuum Breaker, 3/8" x 36" Flex Water Connector, & Quick Disconnect Drawn JRM Checked KJG Approved JHB Scale: NTS Date: 06/23/09 Sheet: 1 of 2 T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 Travelers Rest, SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax: 864-834 REG. #A2601 ISO #9001 -3518 www.tsbrass.com Model No. ORK-SK Item No. (Sold Separately) ITEM NO. SALES NO. DESCRIPTION 1 002535-25 3/8" Close Nipple 2 062A 3/8 NPT Male x 1/2 NPT Male 3 AW -5B QD Water Socket/Plug 3/8" Brass 4 HW -2B-36 3/8 NPT x 36" Flex Water Hose 5 B-0963 B-0963 VB 6 B-0109-01 Bracket Assembly, 6" Wall 7 014200-45 Star Washer, Anti -Rotation Product Specifications: 1/2 NPT Inlet Elbow, 3/8" x 18" Riser, Vacuum Breaker, 3/8" x 36" Flex Water Connector, & Quick Disconnect Drawn JRM Checked KJG Approved JHB Scale: NTS Date: 06/23/09 Sheet: 2 of 2 Vent -Free unary Seri.es... where s tperior i ce and unique r rsa ti ty ar fid ; -in an ultramod'eir i design. rp ece-o fire, but a resenc, resents iuxut with ar Innovation on Fire wtuiu.FMIPRODUCFS.co»? Sleek & Sophisticated Introducing the Luminary Series Linear Vent -Free Fireplace System, Paris Lights. These dynamic new p .^ chic and polished style with adaptabili thought of, yet. Paris Lights fireplaces span 43" across. Reflective black porcelain lined interior walls amplify the flame and boast the power of the fire. The lively blaze is highlighted by a glowing tray of embers and is innovatively accented with hallogen lighting. Crystal clear glass stones add sparkle to the dazzling yellow flames and are elegantly illuminated as the lights I') , shine through from underneath. Create ambiance with the mood lighting,whether the fire is burning or not. The`cutting edge linear design is far from traditional, yet all controls \ are concealed so the finished look remains clean and effortless. This standoutseries is beyond accommodating when it comes to application. i Paris Lights Vent -Free fireplaces have the ability to transform to see-thru -models with the LVSTI Vent -Free See-Thru Conversion Kit. Finish' your Luminary right up to the edge or opt for one of our Decorative Face Trims, available in three colors. Features • Reflective Black Porcelain Lined Interior • Crystal Clear Glass Pebble Burner • Electronic Ignition with Adjustable Flame • Mood Lighting • Operates with Included Remote Control • Approved ANSI Z21.1i.2 atace Accessories • Linear Vent -Free See-Thru Conversion Kit • Decorative Face Trim • Smooth Glass Pebbles In Four Colors FMI PRODUCTS, LLC www.FMIPRODUCTS.com For more information, call (866) 328-4537 You can easily convert your Linear Fireplace to a See-Thru model and enjoy the flame from two rooms at once! Be bold with one of our Decorative Face Trim Frames in aged silver, aged copper or black. Glass Pebbles available in Amber, Speckled Orange, Green and Blue. -,= p Linear Offeri�ngr i; j= MODEL SIZE FUEL BTU's LVF43NR 43° Natural 39,000 LVF43PR 43" Propane 37,000 Firebox Dimensions 171/2" 16 /2" ATa 5/8• 1 A I1g A 189/32" 7132' 11 i 0 0 2913/16" 441/16' 52' 551/16' © 2012 FMI PRODUCTS, LLC NFI NATIONAL FIREPLACE INSTITUTE PFS Tested & Certified FA5520-0212 Product design, features and specifications are subject to change at any time. Refer to current product Instructions prior to installation. Printed in U.S.A. 03 CD CD o_ D Lights 3 Prong Plug To J -Box Orange/Yellow/Brown/Black Power Module Grey/Black/Red Orange/Yellow/Brown/Black White Green Red Black Pink Blue Not Used Battery Backup SIZE '9V' w m n Pilot Switch co E m m White 0 a CD 3 Black Black Red Yellow Control Module Sense Electrode Screwed to Pilot> Bracket NOR -LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 800-388-5253 Service 866-961-5253 Parts 715-386-6149 FAX www.norlake.com NOR LAKE 0 FO ELO ETM CL TO WALK-ONS O 0 3 kl 0 0 0 0 0 0 0 0 0 0 0 O 0 0 ) 0 0 A J 0 0 0 O J 0 0 O 0 0 ) 0 3 .5 'Y 0 3 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 3 J 0 0 0 O 0 .3 J J 3 0 0 0 0 0 0 0 0 O 0 3 J 0 0 0 0 0 0 0 0 0 0 0 CONDENSED SPECIFICATIONS FOR ARCHITECTS AND CONSULTANTS STANDARD FEATURES o Coolers, freezers and combination cooler/freezers o Modular panel construction for easy installation, expansion and relocation o 26 gauge corrosion resistant stucco embossed coated steel o .100 smooth aluminum interior floor (on models with floor) a Floorless models provided with NSF approved vinyl sealers, foamed -in- place screeds or female bottom rails a Full 4" or 5" thick panels foamed -in-place with HFC -134a polyurethane insulation which is CFC & HCFC Free. Zero Ozone Depletion o Doors equipped with heavy duty polished chrome hardware o Heavy duty, extruded, anodized aluminum load bearing door frame jamb o Deadbolt locking handle with independent key/padlock feature and inside safety release o Vapor proof light fixture o Magnetic door gaskets and spring actuated door closer o Heated pressure relief port on all freezers o Indoor and outdoor roof and ceiling support systems o Fifteen year panel warranty o NSF approved o UL & FM flame spread 25 approved panels o UL and CSA electrical approved door section o City of New York (MEA) approved o City of Los Angeles approved a City of Houston approved o Oregon State approved o State of Wisconsin Building Product approved o USDA accepted o Factory Mutual o Registered by UL to ISO 9001:2008 OPTIONS a Selection of interior and exterior surfaces and finishes a Various door styles and sizes o Wide range of computer sized and balanced refrigeration systems a Indoor and outdoor roof and ceiling support systems DESIGNED TO YOUR SPECIFICATIONS! PROJECT: ITEM NUMBER: ITEM 7 MODEL NUMBER: ACCESSORIES o Interior and exterior door kickplates o Cooler and freezer door viewports o Interior and exterior ramps o Bumper rails, trim strips and closure panels o Various security alarm systems o Extra lights and special switches o Shelving (free-standing) o Special floor underlayments and topside plating SPECIFICATIONS 1.0 GENERAL; id Walk-in coolers and freezers to consist of precision constructed modular 4" or 5" thick rigid polyurethane foamed -in-place interchangeable panels. Panels are designed for easy installation, expansion and relocation. >3 Panels shall be prefabricated modular construction consisting of 100% foamed -in-place polyurethane insulation, bonded by an adhesive to the interior and the exterior metal pan skins and heat cured for life long stability. .1.3 Each wall panel skin is to be formed using a double 90° bend on each edge to add strength and rigidity. Panels are to be in 6 inch increments, with a minimum width of 12 inches. Nor -Lake, Inc. Registered to ISO 9001:2008 File No. 10001816 a 4:0 SPECIFICATION GUIDE 1.4 All panels are to bear the UL, FM and NSF label. The panels shall incorporate cam lock type fasteners with reverse wing structural support as joining devices for the adjacent tongue and groove panels. Each device is to consist of a cam action locking arm and a steel rod in adjoining panel so that by rotating the locking arm, the hook engages over the rod and the cam action draws the panel together. The resulting panel joints shall be sealed by a foamed -in-place, continuous one piece gasket. 1.5 Panel joints are to be precisely formed male and female tongue and groove shapes fabricated to force the male edge to contact the female edge, providing additional seal. The panel joint shall have a gasket which provides a positive seal that meets NSF standards. Gasket shall be "locked" to the skins and run in a continuous piece, completely around the panel with only one break to provide the optimal seal. z.0 INSULATION 2_1 Insulation shall be a full 4 inches or 5 inches thick, UL and FM Class 1 rigid foamed -in-place HFC -134a polyurethane with a minimum 2.0 lbs/cubic foot density. Foam polyurethane shall be injected into the panels by means of a high output, high impingement, froth mixer. Poured -in-place foam injection is not acceptable. 2_2 Environmentally friendly HFC -134A polyurethane foam insulation provides a minimum "R" value of 9 per inch of thickness at a very low mean core temperature. 2_3 Insulation shall be 95% closed cell structure. Flame spread rating according to ASTM E-84/UL 723 shall be 25 or less. 2_4 The use of R-12 and/or R-22 as a blowing agent is specifically prohibited. 3.0 FLOOR STYLES: 3_1 Less floor 4" wall walk-ins shall be supplied with PVC extruded floor sealers with semi -flexible edges, which seal to floor without the use of exposed fasteners. Sealer shall encase the wall panel on both interior and exterior surfaces with a flexible rubber collar a minimum of 3" high from finished building floor. Sealer shall meet NSF requirements for floor cove molding. Additional less floor options include female bottom rail walls for 4" and 5" thick walk-ins and various height foam sealers for 4" thick walk-ins. Consult factory for detailed specifications. 3_2 With floor walk-ins shall be a full 4 inches thick with one piece foamed -in-place edge caps. Edge caps include metal formed adhesion edges which result in the edge caps being a foamed integrated member of the floor panels. Glued -in-place edge caps are not acceptable. Floor panels shall be designed to withstand uniformly distributed loads of 800 pounds per square foot. The joint between the floor and wall shall form a NSF approved 45° angle to allow for easy cleaning. 4.0 CEILING PANELS.. 4_1 Ceiling panels shall be a full 4 inches or 5 inches thick with one piece foamed -in-place edge caps. Edge caps include metal formed adhesion edges which result in the edge caps being a foamed integrated member of the ceiling panels. Glued -in-place edge caps are not acceptable. 4_2 Metal face skins are to incorporate seams using a double 90° bend at a maximum width of two feet for additional strength. The joint between the ceiling and wall shall form a 45° angle to allow for easy cleaning. 5.0 FINISHES; `j The interior and exterior walls and interior ceiling shall be supplied with 26 gauge corrosion resistant stucco embossed coated steel. The interior floor surface (when applicable) shall be .100 smooth aluminum. Other finisheds are available. 6.0 DOOR CONSTRUCTION; 6_1 Entrance door shall be in fitting, flush design. The door section shall provide a full 4 inches or 5 inches of polyurethane HFC -134a insulation, NORLAKE Revision Date: 1/10 © 2010 NOR -LAKE, INC. Printed in the U.S.A. Part Number: 090773 00 Mergaga Food Service Equipment Group construction and finish shall be the same as the adjoining wall panels. 6_2 The door shall be 4 inches thick, constructed to incorporate heavy duty, molded ABS breaker strip, which is permanently foamed -in-place. Bottom of door shall seal with an adjustable double sweep gasket, uniquely designed to provide complete seal between door, threshold, and door jamb. 6.3 Door jamb to be a fully coved, extruded, welded, structural anodized aluminum, rigid frame design for easy cleaning and maintenance. 6.4 Threshold plate provided shall be constructed of extruded aluminum for bearing strength. Cooler/freezer shall have an anti -sweat heater wire around the entire perimeter of the door opening and under threshold. The heater wire (standard in both coolers and freezers) shall provide enough heat to prevent condensation. All conduit for the inner -wiring of the door panel shall be totally concealed in the polyurethane foam panel, exposed conduit is not acceptable. 6.6 Door section to be field wired to surface mounted junction box on the interior door panel. The door size, location and swing to be as indicated in Specifications Drawings. 6_7 Door hardware shall be highly polished chromium plated steel. Hardware shall include a spring actuated door closer, field adjustable cam lift hinges, & deadbolt locking handle with independent key/padlock feature and inside safety release. All hardware shall be attached to extra large 1/2 inch thick, nonconducting synthetic tapping plates. 6.8 Digital thermometer calibrated to indicate interior walk-in temperature shall be provided with each entrance door. Remote incandescent vapor proof gasketed UL listed light fixture, made of cast aluminum with plastic coated glass globe. Mounted. at the interior handle side of the door section. Locate light switch with pilot light adjacent to door, on exterior handle side of door section, with all inner wiring in rigid conduit concealed inside the door section and terminated at a surface mounted junction box on the interior door frame. Fixture shall operate on 115 VAC. 7.0 INSTALLATION AND MAINTENANCE: 7.1 Included with each walk-in shipment is a complete set of installation instructions covering all phases of panel erection, accessories, and maintenance procedures. 8.0 APPROVALS 8.1 Walk-in construction is approved by NSF International and shall have the NSF seal on the door section. 8.2 Walk-in panels shall have a UL & FM flame spread rating of 25. 8_3 The door section shall be UL and CSA approved as an electrically approved assembly. 84 City of Los Angeles approved, City of Houston approved, Oregon State approved, State of Wisconsin Building Product approved, USDA accepted, Factory Mutual Specification tested. 9.0 WARRANTIES: 9.1 Manufacturer shall provide a written warranty to the owner stating the product is free from defects or workmanship under normal use and service. Warranty shall become effective following the acceptance date and cover the insulated panels for a period of fifteen years and parts for a period of 18 months. 10.0 QUALITY ASSURANCE: 10.1 To insure the finest quality in material and workmanship the above specifications shall be held in full compliance. Please specify the walk-in cooler or freezer is to be as manufactured by Nor -Lake, Incorporated, Hudson, Wisconsin. 10.2 Contact Nor -Lake, Incorporated for a copy of the most detailed Specification Manual available in the Foodservice Industry. 11.0 SITE CONDITIONS: 11_1: To assure proper operation, site conditions should be controlled. The walk-in product should be in a well ventilated location. Indoor ambient conditions should be controlled, relative humidity between 30%-60% and maintaining a dew point of 50°F (or less). fEBEI�S FO DSERVICE, LLC Item # _ Job ITEM 8 FOCUS SHELVING Wire Shelving • C es6gsa: The open wire design of these heavy gauge chrome or epoxy coated shelves minimizes dust accumulation and allows a free circulation of air, greater visibility of stored items and greater light penetration. • Ifeasecine: FOCUS SHELVING can change as quickly as your needs change. By using various sizes, hundreds of shelving configurations become possible. • 17054 and Some Asseriablly: Posts with the double groove visual guide feature, have circular grooves at I° (25mm) intervals and are numbered at 2" (50mm) intervals. A tapered split sleeve (plastic) snaps together around each postTapered openings in the shelf comers slide over the tapered split sleeves to lock on the shelf. Shelf is assembled in minutes without the use of any special tools. • $QoeC1 fabs: Run front to back allowing you to slide items on and off shelves smoothly. • $6secQ Aacessaaatny: Shelves can be adjusted at I" (25mm) intervals along the entire length of the post. • DaonofbOes FOCUS wire shelving is available in two finishes: chromate & epoxy coated. • &a rros4h a ffee0: Boft levelers compensate for uneven surfaces. • $4nenol4Qo: Each shelf up to 48" in length is rated to support up to 800 lbs. of uniformly distributed weight Shelves longer than 48" support 600 lbs. Focus Foodservice, LLC • 300 Knightsbridge Parkway, Suite 500 • Lincolnshire, IL 60069 • www.focusfoodservice.com FOCUS SHELVING WIRE SHELVING Job Wire Shelves Split Sleeves "S" Hooks Used to "add-on" shelving units with only two posts required. Item No. 93333 Chromate Item No. 93333GN Green Epoxy Posts Posts are grooved at I" (25mm) increments and numbered at 2" (50mm) increments. Posts are double grooved every 8" (203mm) for easy identification. Width Length Approx. Pkd.Wt Item No. Item No. (in) (mm) (in) (mm) (lbs.) (kg) Chromate Epoxy 12 305 36 914 7 3.1 FF 1236C FF 1236GN 12 305 48 1220 9 4.1 FF 1248C FF 1248GN 12 305 60 1524 13 5.8 FF 1260C FF 126OGN 14 355 24 610 6 2.7 FF 1424C FF 1424G 14 355 30 760 7 3.2 FF 1430C FF 1430G 14 355 36 910 8 3.6 FF 1436C FF 1436G 14 355 42 1060 9.5 4.3 FF 1442C FF 1442G 14 355 48 1220 10.5 4.7 FF 1448C FF 1448G 14 355 60 1525 14 6.3 FFI460C FFI460G 14 355 72 1825 17 7.7 FF 1 472C FF 1 472G 18 455 18 455 5.6 2.55 FFI8I8CH 18 455 24 610 7 3.2 FF 1824C FF 1824G 18 455 30 760 8 3.6 FF 1830C FF 1830G 18 455 36 910 9.5 4.3 FF 1836C FF 18366 18 455 42 1060 1 I 5.0 FF 1842C FF 1842G 18 455 48 1220 12 5.4 FF 1848C FF 1848G 18 455 54 1370 14.5 6.6 FF 1854C FF 1854G 18 455 60 1525 17 7.7 FF 1860C FF 1860G 18 455 72 1825 20 9.1 FF 1872C FF 1872G 21 530 24 610 8 3.6 FF2124C FF2124G 21 530 30 760 9 4.1 FF2I30C FF2130G 21 530 36 910 11 5.0 FF2136C FF2136G 21 530 42 1060 12 5.4 FF2142C FF2142G 21 530 48 1220 14 6.4 FF2148C FF2148G 21 530 54 1370 16 7.6 FF2154C FF2154G 21 530 60 1525 18 8.2 FF2160C FF2I60G 21 530 72 1825 24 10.9 FF2172C FF2172G 24 610 24 610 9 4.1 FF2424C FF2424G 24 610 30 760 1I 5.0 FF2430C FF2430G 24 610 36 910 13 5.9 FF2436C FF2436G 24 610 42 1060 15 6.8 FF2442C FF2442G 24 610 48 1220 16 7.3 FF2448C FF2448G 24 610 54 1370 18 8.6 FF2454C FF2454G 24 610 60 1525 21 9.5 FF2460C FF2460G 24 610 72 1825 26 11.8 FF2472C FF2472G 30 760 36 910 33.2 15.1 FF3036CH 30 760 60 1525 53.4 24.3 FF3060CH FF306OGN 11 Height Approx Pkd.Wt Item No. Item No. (in.) (mm) (lbs.) (kg) Chromate* Epoxy 7 190 05 0.2 FGOO7C F0007G 13 368 1 0.5 FG013C FGOI3G 33 876 2 0.9 FG033C FG033G 54 1386 3 1.4 FG054C FG054G 63 1589 3.5 1.6 FG063C FG063G 74 1895 4 1.8 FG074C FG074G 86 2200 5 2.3 FG086C FG086G *Note: for mobile post use the prefix "FGN" ous I FOODSERVICE. EEC 1 Pam Foodservice, Phone 800-968- kW 0 00 3900°G Knightsbridge Parkway, 800-968-4 07 00 0 Lincolnshire, 60069 www.focusfoodservice.com FOODSERVICE, LLC Item # _ Job ITEM 8.1 NS FOCUS SHELVING Wire Shelving • DD iasiijoo: The open wire design of these heavy gauge chrome or epoxy coated shelves minimizes dust accumulation and allows a free circulation of air, greater visibility of stored items and greater light penetration. • Veusao46De: FOCUS SHELVING can change as quickly as your needs change. By using various sizes, hundreds of shelving configurations become possible. • vent a000dl Seams e 11u ssasaooi p Posts with the double groove visual guide feature, have circular grooves at I" (25mm) intervals and are numbered at 2" (50mm) intervals. A tapered split sleeve (plastic) snaps together around each post.Tapered openings in the shelf corners slide over the tapered split sleeves to lock on the shelf. Shelf is assembled in minutes without the use of any special tools. • SlloaaOQ L"3nlbs: Run front to back, allowing you to slide items on and off shelves smoothly. • SIloe04 aaaQ,ssi iilEy: Shelves can be adjusted at I" (25mm) intervals along the entire length of the post. • Iwnr lkolle: FOCUS wire shelving is available in two finishes: chromate & epoxy coated. • 6bldlpans4®QoOe Fee4: Bolt levelers compensate for uneven surfaces. • Sff eoogo: Each shelf up to 48" in length is rated to support up to 800 lbs. of uniformly distributed weight. Shelves longer than 48" support 600 lbs. Focus Foodservice, LLC • 300 Knightsbridge Parkway, Suite 500 • Lincolnshire, IL 60069 • www.focusfoodservice.com FOCUS SHELVING WIRE SHELVING Job Wire Shelves Split Sleeves "S" Hooks Used to "add-on" shelving units with only two posts required. Item No. 93333 Chromate Item No. 93333GN Green Epoxy Width Length Approx. Pkd.Wt. Item No. Item No. (in) (mm) (in) (mm) (lbs.) (kg) Chromate Epoxy 12 305 36 914 7 3.1 FF 1236C FFI236GN 12 305 48 1220 9 4.1 FF 1248C FF 1248GN 12 305 60 1524 13 5.8 FF 1260C FF 126OGN 14 355 24 610 6 2.7 FF 1424C FF 1424G 14 355 30 760 7 3.2 FF 1430C FF 1430G 14 355 36 910 8 3.6 FF 1436C FF 1436G 14 355 42 1060 9.5 4.3 FF 1442C FF 1442G 14 355 48 1220 10.5 4.7 FF 1448C FF 1448G 14 355 60 1525 14 6.3 FF 1460C FF 1460G 14 355 72 1825 17 7.7 FF1472C FF1472G 18 455 18 455 5.6 2.55 FF 18 18CH 18 455 24 610 7 3.2 FF 1824C FF 1824G 18 455 30 760 8 3.6 FF 1830C FF 1830G 18 455 36 910 9.5 4.3 FF 1836C FF 1836G 18 455 42 1060 11 5.0 FF1842C FF1842G 18 455 48 1220 12 5.4 FF 1848C FF 1848G 18 455 54 1370 14.5 6.6 FF 1854C FF 1854G 18 455 60 1525 17 7.7 FF 1860C FF 1860G 18 455 72 1825 20 9.1 FF1872C FF1872G 21 530 24 610 8 3.6 FF2124C FF2124G 21 530 30 760 9 4.1 FF2I30C FF2I30G 21 530 36 910 I1 5.0 FF2136C FF2136G 21 530 42 1060 12 5.4 FF2142C FF2142G 21 530 48 1220 14 6.4 FF2148C FF2148G 21 530 54 1370 16 7.6 FF2154C FF2154G 21 530 60 1525 18 8.2 FF2I60C FF2I60G 21 530 72 1825 24 10.9 FF2172C FF2172G 24 610 24 610 9 4.1 FF2424C FF2424G 24 610 30 760 11 5.0 FF2430C FF2430G 24 610 36 910 13 5.9 FF2436C FF2436G 24 610 42 1060 15 6.8 FF2442C FF2442G 24 610 48 1220 16 7.3 FF2448C FF2448G 24 610 54 1370 18 8.6 FF2454C FF2454G 24 610 60 1525 21 9.5 FF2460C FF2460G 24 610 72 1825 26 11.8 FF2472C FF2472G 30 760 36 910 33.2 15.1 FF3036CH 30 760 60 1525 53.4 24.3 FF3060CH FF306OGN Posts Posts are grooved at 1" (25mm) increments and numbered at 2" (50mm) increments. Posts are double grooved every 8" (203mm) for easy identification. Height Approx. Pkd.Wt. Item No. Item No. (in.) (mm) (lbs.) (kg) Chromate* Epoxy* 7 190 0.5 0.2 FGOO7C FG007G 13 368 1 0.5 FGO 1 3C FGO13G 33 876 2 0.9 FG033C FG033G 54 1386 3 1.4 FG054C FG054G 63 1589 3.5 1.6 FG063C FG063G 74 1895 4 1.8 FG074C FG074G 86 2200 5 2.3 FG086C FG086G *Note: for mobile post use the prefix "FGN" FOODSERVICE, LLC Focus Foodservice, LLC • 300 Knightsbridge Parkway, Suite 500 • Lincolnshire, IL 60069 Phone 800-968-3918 • Fax 800-968-4129 • www.focusfoodservice.com rev. 0311 1 F24 20' 8 3/4• 191/8' 18GA TUBING DETAIL: 24 �1' � 18' 1 1/2' Lr 1- ]— s s UP ..-24 318 ) -I 10' 031/2' MARINE EDGE F24 5/8'--{ 19 1/8'7 6• DEEP BOWL 18GA S.S. TX? TUBING WELDED TO SIDES 3 SIDED SKIRT OPEN IN BACK. SKIRT WELDED ON. JOHN BOOS & CO. 315 SOUTH FIRST STREET P.O. BOX 609 EFFINGHMI. IL. 62401 (217) 347.7701/FAX (217) 347.7705 E.MAK: salesaahraboostxim Web Slte: wwW joMOommm REVISIONS: JOHN BOOS 8 COMPANY E SERIES THIS UUWN° AHO THE OESIG4 SHOWN ARE THE PROPERTY OF JUN E005 a CO. REPRODUCTION. INFRINGEMENT OR ANY OTHER UNAUT/ OZFD USE OF THIS DRAWING WITHOUT TIE WRITTEN CONSENT OF JUN BOOS a CO. W0.L BE SUBJECT TOHE0AL ACTION. wnN a30H0 (0 MARINE EDGE DETAIL MATERIALS DECK: 16GA. SS. BASE: S.S. c m z c g 8 C z 1D tom. CJW m z c 3 ADVANCE TABCO. SMART FABRICATION 8" Wide DETAILS TOL ± .500" STAINLESS STEEL UTILITY SHELF Item #: Qty #: Model #: Project #: FEATURES: Furnished with Mop Hangers and Hooks for hanging rags. Both rag hooks and mop hangers are spot welded to shelf. CONSTRUCTION: Shelf and brackets are die formed. MATERIAL: 18 gauge stainless steel type "430" polished to a satin finish. ADVANCE TABCO is constantly engaged in a program of improving our products. Therefore, we reserve the nght to change specifications without prior notice. © ADVANCE TABCO, JAN. 2005 L-8 T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 REG. #A2601 ISO #9001 Travelers Rest, SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax: 864-834-3518 www.tsbrass.com Model No. B-0665-BSTR Item No. This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity Customer/Wholesaler Contractor Architect/Engineer f.7 ADA Compliant Support Rod, Furnished w/ Wall Bracket & Mounting Screws Eterna Cartridges w/ Spring Check & Lever Handles w/ Color Coded Indexes 14 3/8" [ 364mm ] --Wall B-0969 1/2" NPT Vacuum Breaker Support Rod Not Shown Rough Chrome Finish on Faucet Body & Spout 1/2" NPT Female Inlets 2 5/8" [68mm] 6 1/2" [164mm] 9 1/8" [ 232mm ] 8" [ 203mm ] Adjustable From 7 3/4" to 8 1/4" [197mm to 210mm] Male Garden Hose Connection 0 2" [51 mm] Flanges Integral Service Stop Product Specifications: Service Sink, Inlet Stops, Eterna Spring Check Cartridges, Lever Handles, Rough Chrome Drawn DHL Checked JRM Approved JHB Scale: 1:4 Date: 03/22/11 Sheet: 1 of 2 T&S18 SS LID E:RONZE WORKS, ONC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 REG. RA2601 6O #9001 Travelers Rest, SC: 800-476-4103 • Simi Valley, CA: 800-423-0150 • Fax: 864-834-3518 • www.tsbrass.com Model No. B-0665-BSTR Item No. ITEM NO. SALES NO. DESCRIPTION 1 009545-40 2 009546-40 Spout Asm Rough Chrome w/ Support Clevis Suprt Rod B-0665 - Polish Chrome 3 4 5 6 7 8 9 10 11 12 13 14 15 B-0969 002534-25 001661-45 000922-45 002711-40 001660-45 00AA 001019-45 012442-40 163A 002712-40 012443-40 001638-45 1/2" NPT Vacuum Breaker Close Nipple, 1/2" x 1 5/32" Lg Rough Chrome Red Index -HW Lever Handle Screw Cold Eterna Spindle Asm w/ Spring Check, Handle, Index & Screw Blue Index -CW 1/2" NPT Wall Flange Coupling Nut Washer Cold Eterna Spindle Assembly w/ Spring Check BST Assembly, 163A Hot Eterna Spindle Asm w/ Spring Check, Handle, Index & Screw Hot Eterna Spindle Assembly w/ Spring Check Lever Handle Product Specifications: Service Sink, Inlet Stops, Eterna Spring Check Cartridges, Lever Handles, Rough Chrome Drawn DHL Checked JRM Approved JHB Scale: NTS Date: 03/22/11 Sheet: 2 of 2 T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 REG. #A2601 ISO #9001 Travelers Rest, SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax: 864-834-3518 www.tsbrass.com This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity Customer/Wholesaler Contractor Architect/Engineer 5 3/4" [146mm] Model No. B-3950 Item No. Removable Snap -in Strainer 04 7/16" [113mm] 2 5/8" [68mm] Adapter Converts 2" NPT Male to 1 1/2" NPT Male. Remove Adapter When 2" NPT Male Thread is Needed. 12 1/4"±1/4" [312mm] Twist Handle w/ Heat Resistant Plastic Grip (Shown in Open Position) LOCKED 60° \,c 180° CLOSED - HANDLE ORIENTATION OPENED Product Specifications: Rotary Waste Valve w/ Twist Handle, 3 1/2" Sink Opening, 2" NPT Male Outlet & 1 1/2" NPT Male Adapter Drawn DHL Checked JRM Approved JHB Scale: 1:4 Date: 3/19/07 Sheet: 1 of 2 T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 Travelers Rest, SC: 800-476-4103 REG. #A2601 6O #9001 Simi Valley, CA: 800-423-0150 Fax: 864-834-3518 www.tsbrass.com Model No. B-3950 Item No. ITEM NO. SALES NO. 1 010389-45 2 010391-45 3 010390-45 4 010382-45 5 010384-45 6 010386-45 7 010388-45 8 010393-45 9 B-3945 DESCRIPTION 0 -Ring, Plunger Nut, Coupling For Twist Drain Ferrule, Coupling Nut Gasket, 3 1/2" Face Flange Flange, 3 1/2" Face Strainer, 3 1/2" Snap -in Removable Plunger, Twist Drain Handle Asm, Rotary Waste Valve Twist Adapter, 2" NPT x 1 1/2" NPT Also Furnished w/ Sealing Cap When Overflow Tube Coupling Nut is Not Used. PN# 012640-45 Washers, 0 -Rings & Gaskets are included in Parts Kit B -39K Product Specifications: Rotary Waste Valve w/ Twist Handle, 3 1/2" Sink Opening, 2" NPT Male Outlet & 1 1/2" NPT Male Adapter Drawn DHL Checked JRM Approved JHB Scale: 1:4 Date: 3/19/07 Sheet: 2 of 2 MMS BRASS AND BRONZE WORTS, O C. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 REG. RA2601 LSO 09001 Travelers Rest, SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax: 864-834-3518 www.tsbrass.com Model No. 1128 Item No. This Space for Architect/Engineer Approval Job Name Model Specified Customer/Wholesaler Contractor Date Quantity Architect/Engineer 8" [203mm] 062X 12" Swing Nozzle w/ B -PT Stream Regulator Outlet [1 A Complaint 1/2" NPT Male Shanks (Requires 01" [025mm] Cutouts) Tailpieces Not Shown in This View Mountin• Surface 1" [25mm] Lever Handles w/ Color Coded Indexes B -1100-K Elbow Kit Sold Separately. Contains (2) 1/2" NPT Male 90° Elbows 1/4" [6mm] Max. Mounting Surface Thickness 12" [305mm] 14 7/16" [367mm] of Polished Chrome Plated Escutcheon r 7 3/8" 4 5/8" [187mm] [117mm] 10 1/2" [267mm] 2" [51 mm] 150A Tailpiece and Nut Furnished for 1/4" NPT Connection Product Specifications: 8" Inlet Centers Wall Mount Faucet w/ Lever Handles, 12" Swing Nozzle Assembly, B -PT Stream Regulator & 1/2" NPT Male Shanks Drawn KJG Checked DHL Approved JHB Scale: 1:4 Date: 09/29/08 Sheet: 1 of 2 ocu T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove I P.O. Box 1088 Travelers Rest, SC 29690 REG. #A2601 ISO #9001 Travelers Rest, SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax: 864-834-3518 www.tsbrass.com Model No. B-1128 Item No. ITEM NO. SALES NO. DESCRIPTION 1 001048-45 Nozzle Tip Washer 2 B -PT Stream Regulator Outlet 3 009753-25 B-1100 RH Spindle Assembly 4 001661-45 Red Index -HW 5 062X 12" Swing Nozzle Assembly 6 009538-45 Swivel Washer 7 8 011429-45 Swivel Sleeves (2) 001074-45 0 -Ring 9 001017-45 Washer 10 000922-45 Lever Handle Screw 11 001660-45 Blue Index -CW 12 001638-45 Lever Handle 13 009749-25 Bonnet Nut 14 15 16 17 18 19 20 009754-25 000712-25 000763-20 001259-40 B-1100 LH Spindle Assembly Escutcheon Lock Nut Seat Escutcheon 000999-45 Brass Lock Washer 002954-45 Shank Lock Nut 150A Bag of (1) Nut & (1) Tailpiece Product Specifications: 8" Inlet Centers Wall Mount Faucet w/ Lever Handles, 12" Swing Nozzle Assembly, B -PT Stream Regulator & 1/2" NPT Male Shanks Drawn KJG Checked DHL Approved JHB Scale: NTS Date: 09/29/08 Sheet: 2 of 2 "E3S8-2DB" "E" Series Sinks Three Compartment Sinks w/ 2 Drainboard wl Galvanized Base & Bracing FEATURES: * Standard 18 Gauge Type 300 stainless steel with # 3 polish, satin finish * 12" & 14" Deep Bowls * All Corners, both vertical and horizontal, coved at 3/4" radius * Bottoms of bowls formed for drainage to 3-1/2" diameter die stamped opening * Full length 10" High Boxed Backsplash, with 2" return to wall at 45 degree and 1" tile edge * 1" Faucet Holes in Backsplash * All outside corners of assembly are Bullnosed to provide safe,clean and polished edge * Standard galvanizes legs 1-5/8" diameter * Legs located directly under sink bowls, providing increased stability and maximum weight support CONSTRUCTION: Top: Stainless Steel Sinks are TIG welded, Exposed welds are polished to match adjacent surface. Bases: Galvanized Base MATERIAL: Bowls & 18 gauge stainless Steel Top: Type 300 stainless steel with # 3 polish, satin finish Legs: 1 5/8" Round O.D., galvanzied steel Gussets: Galvanized Feet: 1" adjustable plastic bullet feet STANDARD: 18 ga. 300 S/S welded Bowls 18 ga. 300 S/S sides and Splash 10" Back Splash 12" DEEP 18 Gauge Qty E3S8-1620-12T18 E3S8-18-12T18 _ Bowl Sizes: 16" X 20" 18" X 18" 14" DEEP 18 Gauge Qty E3S8-18-14T18 E3S8-1824-14T18 *E3S8-24-14T24 (*) w/ 2 sets of Faucet Holes Bowl Sizes: 18" X 18" 18" X 24" 24" X 24" 10" DEEP 18 Gauge Qty E3S8-1014-10T15 I Bowl Sizes: 10" X 14" John Boos 86 Co 315 South First Street - Effingham, IL 62401 Phone: 217-347-7701 - Fax: 217-347-7705 Email: sales@johnboos.com - Web -site: www. johnboos.com NN -17 BOWLS DETAILED SPECIFICATIONS F G H 10 X 14 19-7/8" 14" 10" 16 X 20 25-1/2" 20" 12-15/16" 18 X 18 23-1/2" 18" 11-15/16" 18 X 24 29-1/2" 24" 14-15/16" 24 X 24 29-1/2" 24" 14-15/16" G 35 1/4 A 14-1/4" B 12" C 10" D 43-3/4" A 16-1/4" B 14" C io" D 43-3/4" D All dimensions are typical. Tolerance +/- .500". All units ship unassembled for reduced shipping cost. L MODEL s SIVE O 0 O• E3S8-1620-12T18 16 X 20 X 12 STANDARD 12" DEEP MODEL BOWL SIZE DIMENSIONS DB WT. E3S8-1620-12T18 16 X 20 X 12 84" X 25-1/2" 18" 240 E3S8-18-12T18 18 X 18 X 12 90" X 23-1/2" 18" 240 STANDARD 14" DEEP MODEL BOWL SIZE DIMENSIONS DB WT. 1 E3S8-18-14T18 18 X 18 X 14 90" X 23-1/2" 18' 255 E3S8-1824-14T24 18 X 24 X 14 104" X 29-1/2" 24" 288 E3S8-24-14T24 24 X 24 X 14 120" X 29-1/2" 24" 270 STANDARD 10" DEEP MODEL BOWL SIZE DIMENSIONS DB WT. E3S8-1014-10T15 10 X 14X 10 60" X 19-7/8" 15" 95 John Boos & Co 315 South First - Effingham, IL 62401 Phone: 217-347-7701 - Fax: 217-347-7705 Email: sales@johnboos.com - Web -site: www.johnboos.com A 12" B 10" C 10" D 39-3/4" Model No. - . TICS BRASS AND BRONZE WORKS, INC. I -S 2 SADDLEBACK COVE / P.O. BOX 1088 / TRAVELERS REST, SC 29690 - PHONE 800-476-4103 - FAX 864- 834-3518 REG.QA2601 ISO0900 'BUILT B-2278 , \ RELIABILITY IN , Job Name: Architect/Engineer Approval: Notes: EPAct2005 COMPLIANT l& B. == 4,\'1171#4si e B -0044-H FLEX. ST. STEEL 11. e •---� HOSE FINGER HOOK ° �(ili 39 7/16 WALL��,� [1002mm] BRACKET ii Am- V ° 15"0 4 OPTIONAL B-0425 SUPPLY NIPPLES [318mm] Afa 13 1 [349mm] I 3/4" EASY -INSTALL BARER R BELOW ADD-ON-FCT. tml 'mai. a = ■. 1.,;.imir n 2 3/8" [61mm] 1 I 8" 1 2" DIA. FLANGES I w/ 1/2" NPT FEMALE INLETS I- �J WALL or BACKSPLASH SIDE VIEW [203mm] FRONT VIEW f ° DIMENSIONS MAY VARY ± 1" [25mml Product Description: WALL MOUNT PRE RINSE w/ VACUUM BREAKER Drawn: WJS Checked JRM Scale: 1 :8 Approved J H B Date: 11/03/06 EACLE GROUP Profit from the Eagle Advantage® Specification Sheet Short Form Specifications Eagle Wall Shelf, model . Constructed of 16 gauge type 430, 16 gauge type 304, or 14 gauge type 304 stainless steel. 14" roll on front, with 11A" upturn on rear and ends. Stainless steel mounting brackets are stud welded to shelf. #WS1236-16/3 wall shelf EAGLE GROUP 100 Industrial Boulevard, Clayton, DE 19938-8903 USA Phone: 302-653-3000 • Fax: 302-653-2065 www.eaglegrp.com Foodservice Division: Phone 800-441-8440 MHC/Retail Display Divisions: Phone 800-637-5100 For custom configuration or fabrication needs, contact our SpecFAB® Division. Phone: 302-653-3000 • Fax: 302-653-3091 • e-mail: specfab@eaglegrp.com Item No • Project No • S.I.S. No.: Wall Shelves MODELS: ❑ WS1024-* 0 WS1036-* 0 WS1048-* 0 WS1060-* ❑ WS1072-* ❑ WS1084-* 0 WS1096-* 0 WS10108-* ❑ WS10120-* ❑ WS1224-* ❑ WS1236-* ❑ WS1248-* 0 WS1260-* ❑ WS1272-* 0 WS1284-* ❑ WS1296-* 0 WS12108-* ❑ WS12120-* • See chart on back page for complete model numbers. Wall Mounted Shelves • 11A" (38mm) roll on front. • 11A" (38mm) upturn on rear and ends. • Die -formed stainless steel mounting brackets are stud -welded to shelf. • All stainless steel polished to #3 finish. • Available in 16 gauge type 430, 16 gauge type 304, and 14 gauge type 304 stainless steel. • Wide selection of sizes. frA AUTOQUOTES whar K CL EG02.05 Rev. 03/09 Spec sheets available for viewing, printing or downloading from our online literature library at www.eaglegrp.com Eagle Foodservice Equipment, Eagle MHC, SpecFAB®, and Retail Display are divisions of Eagle Group. ©2009 by the Eagle Group 0 cn CD c-) 0 0 cn CD CD 0 S3A 3LjS IIeM Wall Shelves EACLE GROUP Profit from the Eagle Advantage® 1 f Item No • Project No • S.I.S. No • Wall Mounted Shelves LENGTH a L. TOP VIEW 16 gauge type 430 model # WS1024-16/4 WS1036-16/4 WS1048-16/4 WS1060-16/4 WS1072-16/4 WS1084-16/4 WS1096-1 WS10108-16/4 _WS10120-16/-4 WS1224-16/4 WS1236-16/4 WS1248-16/4 FRONT VIEW 16 gauge type 304 model # WS1024-16/3 WS1036-16/3 WS1048-16/3 WS1060-16/3 WS1072-16/3 WS1084-16/3 5/4 WS1096-16/3 WS10108-16/3 -------- WS10120-16/3 - WS1224-16/3 WS1236-16/3 WS1248-16/3 WS1260-16/4 WS1272-16/4 WS1284-16/4 WS1296-16/4 WS12108-16/4 WS12120-16/4 WS1260 16/3 WS1272-16/3 WS1284-16/3 WS1296-16/3 WS12108-16/3 WS12120-16/3 14 gauge type 304 model # WS1024-14/3 WS1036-14/3 WS1048-1413 WS1060-14/3 WS1072-14/3 WS1084-14/3 WS1096-14/3 WS10108-14/3 WS10120.14/3 WS1224-14/3 WS1236-14/3 WS1248-14/3 WS1260-14/3 WS1272-14/3 WS1284-14/3 WS1296-14/3 WS12108-14/3 WS12120-14/3 1 SIDE VIEW width* length weight in. mm In. mm lbs. kg 10" .254 24" 610 10 4.5 10" 254 36" 914 12 5.4 10" 254 48"1219 15 6.8 10" 254 60" 1524 20 9.0 10" 254 72 1829 22 10.0 10" 254 84" 2134 24 10.9 10" -254 - 96" - 2438 '29 13.2 10" 254 108" 2743 32 14.5 10" 254 _ 120" 3048 34 15.4 12" 305 24" 610 12 5.4 12" 305 36" 914 14 6.4 12" 305 48" 1219 17 7.7 12" 305 — _60" 1524 23 - 10.4 12" 305 72" 1829 25 11.3 12" 305 84" 2134 28 -12.7 12" 305 96" 2438 31 14.1 12" 305 108" 2743 36 16.3 12" 305 120" 3048 39 17.6 15 -and 18- (381 and 457mm)-wide shelves available. To order, replace "12" in model number with a "15" or "18" indicating shelf width. Example: WS1536-16/3 EAGLE GROUP 100 Industrial Boulevard, Clayton, DE 19938-8903 USA Phone: 302-653-3000 • Fax: 302-653-2065 www.eaglegrp.com Foodservice Division: Phone 800-441-8440 MHC/Retail Display Divisions: Phone 800-637-5100 Printed in U.S.A. ©2009 by Eagle Group Rev. 03/09 Spec sheets available for viewing, printing or downloading from our online literature library at www.eaglegrp.com Although every attempt has been made to ensure the accuracy of the information provided, we cannot be held responsible for typographical or printing errors. Information and specifications are subject to change without notice. Please confirm at time of order. Project Model Specified: Quantity Item # CSI Section 11400 G -Series Reach -In Freezers/ Self -Contained Equipped with an easy to use microprocessor control! Model G22010 Model G31310 Model G12010 G SERIES Stainless Steel Front & Door(s) One, Two &Three Section Models, 32" Deep Aside from their anodized aluminum side and interior finishes, Traulsen's G -Series "Dealer's Choice" models meet or exceed the standard specifications and performance of most other brands top tier product offerings. Reliable, energy efficient, and durable, with large individual storage capacities, the high quality G -Series line- up includes a wide range of one, two and three section reach -in refrigerator and freezer models, built in our most popular footprints. They are available with either full or half height doors, and the added convenience of a variety of different door hingings to choose from. In addition, each also includes a number of user-friendly features, making them one of the best overall equipment values in Foodservice today, and the right fit for nearly any commercial application. AVAILABLE MODELS Single Section Two Section Three Section (Formerly Model GLT132WUT) (Formerly Model GLT232NUt) (Formerly Model GLT332NUT) Model # Door Hinging Model # Door Hinging Model # Door Hinging 012000* Half Right 022000* Half Left -Right G31300 Half Left -Right -Right 012001* Half Left G22001* Half Right -Left G31301 Half Left -Left -Right G12010* Full Right 022002* Half Right -Right G31302 Half Right -Right -Right G12011* Full Left G22003* Half Left -Left G31303 Half Left -Left -Left 022010* Full Left -Right G31310 Full Left -Right -Right G22011* Full Right -Left G31311 Full Left -Left -Right 022012* Full Right -Right G31312 Full Right -Right -Right 022013* Full Left -Left G31313 Full Left -Left -Left Standard Product Features • High Quality Stainless Steel Exterior Front and Door(s) • Corrosion Resistant Anodized Aluminum One -Piece Sides • Durable Anodized Aluminum Interior • Microprocessor Control With LED Temperature Readout • Top -Mounted, Balanced, Self -Contained Refrigeration System • Minus 10 Degree F Capable • Large High Humidity Evaporator Coil Outside The Food Zone • Load -Sure Guard Protects Against Improper Loading • Full or Half Length Stainless Steel Doors With Locks • Self -Closing Doors With Stay Open Feature At 120 Degrees • Guaranteed For Life Cam -Lift Hinges • Guaranteed For Life Horizontal Work Flow Door Handle(s) • Automatically Activated Incandescent Lights • Damage Resistant Stainless Steel Breaker Caps • Three (3) Adjustable Epoxy Coated Shelves Per Section, Supported On Shelf Pins (installed at the factory) • Energy Saving Automatic Non -Electric Condensate Evaporator • Magnetic Snap -In Door Gaskets • Gasket Protecting Anodized Aluminum Door Liner • Anti -Condensate Door Perimeter Heaters • Thermostatic Expansion Valve Metering Device Provides Quick Refrigeration Recovery Times • Stainless Steel One -Piece Louver Assembly • 9' Cord & Plug Attached • Set of Four (4) 6" High Casters With Locks • One Year Parts And Labor Warranty • Five Year Compressor Warranty LISTED US Listed by Underwriters Laboratories Inc., to U.S. and Canadian safety standards and Listed by NSF International. Optional Accessory Kits • Additional Epoxy Coated Shelves* • No. 1 Type Tray Slides* To Accommodate either: (1) 18" x 26" or (2) 14" x 18" Sheet Pans, Adjustable To 2" O.C. • No. 4 Type Tray Slides* To Accommodate (1) 18" x 26" Sheet Pans (equips one full section) • Universal Type Tray Slides*To Accommodate Either (1) 18" x 26" or (2) 14" x 18" Sheet Pans, or (2) 12" x 20" Steam Table Pans, Adjustable To 4" O.C. • Chrome Plated Shelves* (for use in lieu of standard shelving) • 6" High Adjustable Legs (for use in lieu of standard casters) • Two Year Service/Labor Warranty Available *Please refer to spec sheetTR35872 for optional accessory kit details NOTE: All optional accessory kits are shipped separately for later installation by others at the jobsite. ENERGY STAR * Noted models are ENERGY STAR' listed. Please refer to www.energystar.gov to view the most up-to-date product listing and performance data. Approval: TRAULSEN 4401 BLUE MOUND RD. PHONE 1 (800) 825-8220 Website: www.traulsen.com FT. WORTH, TX 76106 FAX-MKTG. 1 (817) 624-4302 Project Quantity Model Specified: Item # CSI Section 11400 Specifications Construction, Hardware and Insulation Cabinet exterior front, louver assembly and doors are constructed of 20 gauge stainless steel. Cabinet sides (including returns), interior and door liners are constructed of anodized aluminum. The exterior cabinet top, back and bottom are constructed of heavy gauge aluminized steel. A set of four (4) 6" high casters are included. Doors are equipped with a gasket protecting metal door pan, removable plug cylinder locks and guaranteed for life cam -lift, gravity action, self-closing metal, glide hinges with stay open feature at 120 degrees. Hinges include a concealed switch to automatically activate the interior incandescent lighting. Guaranteed for life, work flow door handles are mounted horizontally over recess in door which limits protrusion from door face into aisleways. Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal. Anti condensate heaters are located behind each door opening. Both the cabinet and door(s) are insulated with an average of 2" thick high density, non -CFC, foamed in place polyurethane. DIMENSIONAL DATA 1 -Section Models 2 -Section Models 3 -Section Models Net capacity cu. ft. 24.2 (686 cu I) 46.0 (1303 cu I) 69.1 (1958 cu I) Length - overall in. 2927s (75.9 cm) 52'% (132.4 cm) 765% (193.8 cm) Depth - overall in. 35 (88.8 cm) 35 (88.8 cm) 35 (88.8 cm) Depth - over body in. 32 (81.3 cm) 32 (81.3 cm) 32 (81.3 cm) Depth - door open 90° in. 57% (146.3 cm) 57% (146.3 cm) 57% (146.3 cm) Clear door width in. 21',4 (53.6 cm) 211,4 (53.6 cm) 21'/e (53.6 cm) Clear half -door height in. 27'1(69.9 cm) 27'1(69.9 cm) 27'1(69.9 cm) Clear full -door height in. 57%(146.3 cm) 575%(146.3 cm) 57%(146.3 cm) Height -overall on 6" casters 83'% (211.5 cm) 83'/. (211.5 cm) 83'/. (211.5 cm) No. Standard Shelves 3 6 9 Shelf area sq. ft.' 18.8 (1.75 sq m) 34.6 (3.21 sq m) 51.9 (4.82 sq m) ELECTRICAL DATA Voltage 115/60/1 115/60/1 208-230/115/60/1 Feed wires with Ground 3 3 4 Full load amperes 9.5 11.2 11.0 REFRIGERATION DATA Refrigerant R -404A R -404A R -404A BTU/HR H.P.2 1930 ('/ HP) 2970 (2/. HP) 4710 (1 HP) SHIPPING DATA Length - crated in. 35 (89 cm) 63 (160 cm) 91 (231 cm) Depth - crated in. 43 (109 cm) 43 (109 cm) 43 (109 cm) Height - crated in. 83'1(212 cm) 83'1(212 cm) 831/2 (212 cm) Volume - crated cu. ft. 71 (2011 cu I) 131 (3711 cu I) 189 (5354 cu I) Net Wt. lbs. 320 (145 kg) 650 (295 kg) 690 (313 kg) Gross Wt. lbs. 410 (186 kg) 700 (318 kg) 870 (395 kg) NOTES NOTE: Figures in parentheses reflect metric equivalents. 1= Figure shown reflects the area of standard shelf compliment plus the additional storage area available on the cabinet bottom. 2= Based on a 90 degree F ambient and -10 degree F evaporator. For remote data please refer to spec sheetTR35837. 1 and 2 Section Models equipped with one NEMA 5-15P Plug 3 -Section Models equipped with one NEMA L14 -20P Plug REQUIRED CLEARANCES In order to assure optimum performance, the condensing unit MUST have an adequate supply of air for cooling purposes. Therefore, the operating location must either have a minimum of 12' clearance overhead of the condensing unit or allow for unrestricted air flow at the back of the unit. Clearance of at least 12"above is required in order o perform certain maintenance tasks. NOTE: When ordering please specify: Voltage, Hinging, Door Size, Options and any ad- ditional warranties. Continued product development may necessitate specification changes without notice. Part No.TR35788 (revised 12/10) Refrigeration System A top mounted, self-contained, balanced refrigeration system using R -404A refrigerant is conveniently located behind the one piece louver assembly. It features an easy to clean front facing condenser, thermostatic expansion valve, air-cooled, hermetic compressor, large, high humidity evaporator coil located outside the food zone and a top mounted non -electric condensate evaporator. A 9' cord and plug is provided. Standard operating temperature is 0 to -5°F (all models are -10 degree F capable in up to 90 degree ambient. Controller The easy to use water resistant microprocessor control system is supplied standard. It includes a 3 -Digit LED Display, and a Fahrenheit or Celsius Temperature Scale Display Capability. Interior Standard interior arrangements include three (3) epoxy coated wire shelves per section, mounted on shelf pins, installed at the factory. Shelves are full -width, and do not have any large gaps between them requiring the use of "bridge" or "junior shelves" Recommended load limit per shelf should not exceed 225 lbs. Warranties Both a one year parts and labor warranty and a five year compressor warranty (self- contained models only) are provided standard. An optional 2na year extended parts and labor warranty is also available. Elevation One -Section Elevation Two -Section Plan - One -Section Plan -Three-Section Elevation Three -Section Plan -Two-Section Section - All Models TRAULSEN 4401 BLUE MOUND RD. PHONE 1 (800) 825-8220 Website: www.traulsen.com FT. WORTH, TX 76106 FAX-MKTG. 1 (817) 624-4302 TILUILES,PAL ITEM 17 DESK, STAINLESS STEEL #304 36" H, 30" D, 24" W / 8" OVERSHELF tr 11 LOCKER, WINHOLT MFG. 78"H, 12"W, 18"D (6 CUBBIES) SPECIFICATIONS (GB -35) 1. 3° inlet/outlets Sch. 40. (No -Hub) 2. Max flow rate: 35 GPM 3. Liquid capacity: 35 Gallons 4. Max grease capacity: 142 lbs. (20 Gallons) 5. Max solids/sediment capacity: 6 Gallons 6. Unit weight w/std. covers: 77 lbs. 7. 2,000 Ib. load rated, bolted, gas/water tight composite covers. 8. Maximum operating temperature 190°F continuous. NOTES 1.Listed by IAPMO to ASME grease interceptor standard #A112.14.3 2. Factory installed Built-in flow control. 3. For gravity drainage applications only. Do not use for pressure applications. 4. 3/8' thick seamless high density polyethylene walls. 5. Unit supplied with built-in adapter for up to 3 1/2" of adjustability. Additional riser(s) are also available for deeper burial depth. 6. Cover placement allows full access to tank for proper maintenance. 7. Vent not required unless per local code. 8. Engineered inlet and outlet diffusers are removable to inspect/clean piping. 9. For on -the -floor or buried applications. 10. Integral Air Relief / Anti -siphon. 11. Three outlet options for easy rough in. Unit shipped with outlet diffuser in outlet B. DIFFUSION FLOW TECHNOLOGY The inlet diffuser splits incoming effluent into two paths that utilize the entire liquid volume of the tank for efficient grease separation. The calibrated openings greatly reduce effluent turbulence. The effluent enters the main chamber without disturbing the existing grease or sediment layers. The integral air relief/anti-siphon in the top of the outlet diffuser allows pressure stabilization within the unit during operation. The bottom of the outlet diffuser allows only effluent which is free of grease to exit the tank. It can easily be attached to any of the three outlets provided to ease jobsite piping layouts. ENGINEER SPECIFICATION GUIDE Schier Great Basin grease interceptor model # shall be lifetime guaranteed and made in USA of seamless, rotationally - molded High Density Polyethylene with minimum 3/8° uniform wall thickness. Interceptor shall be fumished for above or below grade installation. Interceptor shall be built in accordance to ASME A112.14.3 (type C), with field adjustable riser system, built-in flow control, built-in test caps and three outlet options. Interceptor flow rate shall be GPM. Interceptor grease capacity shall be lbs. Cover shall provide water/gas-tight seal and have minimum 2,000 lbs load capacity. OPTIONS: • Telegllde field adjustable risers for extending covers to grade • Male pipe thread connections • 4" or 2" Plain end pipe or male pipe thread connections • Clamping collar kit hiforosplors oii soporaion solid. IKeeapmr, vm» web process system PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BONER PRODUCTS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOWER PRODUCTS IS PROHIBITED. A 33" Outlet "A" (Optional) A of inlet & outlet Outlet "C" (Optional) TOP VIEW 0 24" 0 19" Adjustable adapter Outlet "B" (Standard) See note #10 10" 25" 15" 13- /4" Invert Engineered inlet and outlet diffuser (see description) SECTION "A -A" PART NUMBER: GB -35 Deep structural reinforcing columns ISOMETRIC VIEW 25" 0 I END VIEW ECI'FICA TION DESCRIPTION: GREAT BASIN SERIES POLYETHYLENE GREASE INTERCEPTOR 35 GPM, 35 LIQUID GALLONS, 142 GREASE POUNDS CAPACITY I 1 1 I DWG BY: TEU I 1 1 DATE: 12/7/10 I 9 1 REV: 1 -10/31/11 IBflATL: PE T 1 1 1 Y Schier Products 9500 Woodend Road Edwardsville, KS 66111 Tel: 800-827-7119 Fax: 800-827-9664 www.schlerproducts.com Made in the U.SA II II s 1'1 E PRODUCES Pioneering Drain Line Purity 1 City/ST: Southcenter , Tukwilla WA Method 1- By Pipe Size: Drainage system flow rate (GPM) should be determined based on pipe size. Schier recommends calculating based on half -pipe flows as is standard practice for engineered plumbing systems. FLOW RATES (GPM) BY PIPE SIZE (AT 1/4 "PITCH) UPC HGI Pipe Size ASPE 1/2 for 2 (Nominal) Pipe Flows Minute Drain Time 2" 9 10 Models Meeting The Flow Rate All Models 3" 26 35 GB -35, GB -50, GB -75, GB -250 4" 55 75 GB -75, GB -250 6" 157 250 2 X GB -250 Date: Location: Nov. 26th 2012 Southcenter Parkway Method 2 - By Fixtures: Where fixture dimensions and flow rates of all connected fixtures and equipment are known, HGI interceptors may be sized as follows. Compartment Sink Volume Compartment Width (Inches) 16 Compartment Depth (Inches) 20 Compartment Height (Inches) 11 Number of Compartments 3 Total Volume Inches3 10,560 Sink Bowls in Food Prep Area in Inches3 Cubic inches in 1 Gallon 0.75 Load Factor Drain Down Time as per UPC Flow Rate of Other Fixtures Maximum Flow Rate to Interceptor 10,560 231 0.75 2.5 0 14 ri pim Customer. or Meals er Day Med'uGrease Outp.ut.- No.. Flatware (Weekly) Medium Grease O.utput.- With Flatware (Weekly) High Grease Output - No Flatware (Weekly) HigIMMUR .utput: ,.: With Flatware (Weekly) 100 18 23 25 32 200 35 46 49 64 300 Flow Rate (GPM) 15 20 25 35 50 75 100 Capacity (Lb.) 74 109 75 142 249 616 1076 ri pim Customer. or Meals er Day Med'uGrease Outp.ut.- No.. Flatware (Weekly) Medium Grease O.utput.- With Flatware (Weekly) High Grease Output - No Flatware (Weekly) HigIMMUR .utput: ,.: With Flatware (Weekly) 100 18 23 25 32 200 35 46 49 64 300 53 68 74 96 400 70 91 98 127 500 88 114 123 159 Rev. 1.1 FOODSERVICE, LLC Item # _ Job ITEM 22 FOCUS SHELVING Wire Shelving • Design: The open wire design of these heavy gauge chrome or epoxy coated shelves minimizes dust accumulation and allows a free circulation of air, greater visibility of stored items and greater light penetration. • Versatile: FOCUS SHELVING can change as quickly as your needs change. By using various sizes, hundreds of shelving configurations become possible. • Fast and Secure Assembly: Posts with the double groove visual guide feature, have circular grooves at I" (25mm) intervals and are numbered at 2" (50mm) intervals. A tapered split sleeve (plastic) snaps together around each post.Tapered openings in the shelf corners slide over the tapered split sleeves to lock on the shelf. Shelf is assembled in minutes without the use of any special tools. • Shelf Ribs: Run front to back, allowing you to slide items on and off shelves smoothly. • Shelf Accessibility: Shelves can be adjusted at I" (25mm) intervals along the entire length of the post. • Durable: FOCUS wire shelving is available in two finishes: chromate & epoxy coated. • Adjustable Feet: Bolt levelers compensate for uneven surfaces. • Strength: Each shelf up to 48" in length is rated to support up to 800 lbs. of uniformly distributed weight. Shelves longer than 48" support 600 lbs. Focus Foodservice, LLC • 300 Knightsbridge Parkway, Suite 500 • Lincolnshire, IL 60069 • www.focusfoodservice.com FOCUS SHELVING WIRE SHELVING Job Wire Shelves Split Sleeves "S" Hooks Used to "add-on" shelving units with only two posts required. Item No. 93333 Chromate Item No. 93333GN Green Epoxy Width Length Approx. Pkd.Wt. Item No. Item No. (in) (mm) (in) (mm) (lbs.) (kg) Chromate Epoxy 12 305 36 914 7 3.1 FF 1236C FF 1236GN 12 305 48 1220 9 4.1 FF 1248C FF 1248GN 12 305 60 1524 13 5.8 FFI260C FFI26OGN 14 355 24 610 6 2.7 FF 1424C FF 1424G 14 355 30 760 7 3.2 FF 1430C FF 1430G 14 355 36 910 8 3.6 FF1436C FF1436G 14 355 42 1060 9.5 4.3 FF 1442C FF 1442G 14 355 48 1220 10.5 4.7 FF 1448C FF 1448G 14 355 60 1525 14 6.3 FF 1460C FF 1460G 14 355 72 1825 17 7.7 FF1472C FF1472G 18 455 18 455 5.6 2.55 FF 18 18CH - 18 455 24 610 7 3.2 FF 1824C FF 1824G 18 455 30 760 8 3.6 FF 1830C FF 1830G 18 455 36 910 9.5 4.3 FF 1836C FF 1836G 18 455 42 1060 11 5.0 FF1842C FF1842G 18 455 48 1220 12 5.4 FF 1848C FF 1848G 18 455 54 1370 14.5 6.6 FF 1854C FF 1854G 18 455 60 1525 17 7.7 FFI860C FFI860G 18 455 72 1825 20 9.1 FF1872C FF1872G 21 530 24 610 8 3.6 FF2124C FF2124G 21 530 30 760 9 4.1 FF2130C FF2130G 21 530 36 910 11 5.0 FF2136C FF2136G 21 530 42 1060 12 5.4 FF2142C FF2142G 21 530 48 1220 14 6.4 FF2148C FF2148G 21 530 54 1370 16 7.6 FF2154C FF2154G 21 530 60 1525 18 8.2 FF2I60C FF2160G 21 530 72 1825 24 10.9 FF2172C FF2172G 24 610 24 610 9 4.1 FF2424C FF2424G 24 610 30 760 1I 5.0 FF2430C FF2430G 24 610 36 9 I 0 13 5.9 FF2436C FF2436G 24 610 42 1060 15 6.8 FF2442C FF2442G 24 610 48 1220 16 7.3 FF2448C FF2448G 24 610 54 1370 18 8.6 FF2454C FF2454G 24 610 60 1525 21 9.5 FF2460C FF2460G 24 610 72 1825 26 11.8 FF2472C FF2472G 30 760 36 910 33.2 15.1 FF3036CH - 30 760 60 1525 53.4 24.3 FF3060CH FF306OGN 1 Posts Posts are grooved at 1" (25mm) increments and numbered at 2" (50mm) increments. Posts are double grooved every 8" (203mm) for easy identification. FOCUS FOODSERVICE. LLC Height Approx. Pkd.Wt. Item No. Item No. (in.) (mm) (lbs.) (kg) Chromate* Epoxy* 7 190 0.5 0.2 FGOO7C FG007G 13 368 1 0.5 FG013C FGO 1 3G 33 876 2 0.9 FG033C FG033G 54 1386 3 1.4 FG054C FG054G 63 1589 3.5 1.6 FG063C FG063G 74 1895 4 1.8 FG074C FG074G 86 2200 5 2.3 FG086C FG086G *Note: for mobile post use the prefix "FGN" Focus Foodservice, LLC • 300 Knightsbridge Parkway, Suite 500 • Lincolnshire, IL 60069 Phone 800-968-3918 • Fax 800-968-4129 • www.focusfoodservice.com rev. 0311 (1AllJ® / 6MC) Mp/ Profit from the Eagle Advantage' Short Form Specifications Eagle One -Compartment Utility Sinks, model . Constructed of type 304 or 430 stainless steel with square corners, Euro -Style edging on front, and 8" backsplash. All partitions have V rolled top edge. Faucet holes punched on 8" centers. All outside corners to be bullnosed for clean, safe edges. 1%" O.D. galvanized tubular legs with adjustable bullet feet. t7 tr tr one -compartment utility sink Options / Accessories ❑ Faucets ❑ Detachable drainboard ❑ Lever waste ❑ Lever waste with overflow ❑ Stainless steel legs 0 Stainless steel feet See Spec Sheet #EG20.13E for optional detachable drainboards. Design and Construction Features: ° For numerous applications when NSF approval is not required (For NSF -approved utility sinks, add prefix "N-" to model number. Example: N-2424-1-16/3) ° Entire assembly is fuse welded and planished, providing a one-piece seamless sink unit. ° 34V to 35W' (876 to 902mm) working height. ° Water supply is W" (13mm) IPS for hot and cold lines. Item No • Project No • S.I.S. No • One-Compa mend NJ4W y Sinks with Square Corner C®nshictuo MODELS: ❑ 1818-1-16/4 ❑ 1818-1-16/3 ❑ 1824-1-16/4 ❑ 1824-1-16/3 ❑ 2118-1-16/4 ❑ 2118-1-16/3 ❑ 2124-1-16/4 ❑ 2124-1-16/3 ❑ 2136-1-16/4 ❑ 2136-1-16/3 0 2424-1-16/4 ❑ 2424-1-16/3 ❑ 2436-1-16/4 ❑ 2436-1-16/3 0 2124-1-18-16/4 ❑ 2124-1-18-16/3 ❑ 2424-1-24-16/4 ❑ 2424-1-24-16/3 Top: ° All partitions have euro -style front edge. ° Available with detachable* or welded drainboards. ° 8" (203mm) splash features 2" (51 mm) return to wall on 45° angle, with 1" (25mm) upturn. ° 1V (29mm) faucet holes punched on 8" (203mm) centers. Legs: ° 1Y8" (41 mm) -diameter heavy -gauge galvanized tubing. 0 High -impact corrosion -resistant 1" (25mm) adjustable bullet feet. ° Leg locations fall directly under sink bowl, providing increased stability and maximum weight support. Sink Bowl: ° 16 gauge type 304 or 430 stainless steel. ° 133%"(340mm)-deep compartment. ° 12 -gauge leg gussets welded to a die -cut heavy -gauge reinforcing plate underneath sink bowl. ° Drain hole is 3W"(89mm)-diameter, recessed, and complete with 11A" (38mm) IPS basket -type waste drain, which is shipped loose. EAGLE GROUP 100 Industrial Boulevard, Clayton, DE 19938-8903 USA Phone: 302-653-3000 0 Fax: 302-653-2065 www.eaglegrp.com Foodservice Division: Phone 800-441-8440 MHC/Retail Display Divisions: Phone 800-637-5100 For custom configuration or fabrication needs, contact our SpecFAB® Division. Phone: 302-653-3000 0 Fax: 302-653-3091 0 e-mail: specfab@eaglegrp.com ZWYMQVCDTIES KC EG20.13A Rev. 05/12 f available viewing, printing OQ downloading OM COI online literature library www. eaglegrp. 0!T1 Eagle Foodservice Equipment, Eagle MHC, SpecFAB, and Retail Display are divisions of Eagle Group. 132012 by the Eagle Group Catalog Specification Sheet No. One -Compartment Utility Sinks with Square Corner Construction One-Compartment Utility Sinks with Square Corner Construction EA CLE GROUP Profit from the Eagle Advontoge® Item No • Project No • S.I.S. No • One -Compartment Utility Sinks with Square Corner Construction Drain location for rough -in bowl size dimension a in. mm in. mm 118" 457 11" 279 21" 533 12f 318 24" _610 _ 14" _356 13'18" 340mm DRAIN 2' 51 mm FAUCET 37'18" 0 38718" 962 to 987mm TYPICAL SIDE VIEW Sinks with No Drainboards 0 16 gauge type 430 stainless steel model # 16 gauge type 304 stainless steel model # bowl dimensions width length in. mm in. mm drainboard quantity length in. mm m overall dimensions width length in. mm in. mm weight lbs. kg 1818-1-16/4 1818-1-16/3 18" 457 18" 457 0 n/a 22" 559 19%" 492 53 24.01 18241-16/4 1824-1-16/3 18" 457 24" 610 0 n/a 22" 559 25%" 645 56 25.4 2118-1-16/4 2118-1-16/3 21" 533 18" 457 0 n/a 25" 635 1934" 492 56 25.4 1 2124-1-16/4 2124-1-16/3 21" 533 24" 610 0 n/a 25" 635 254" 645 59 26.8 2136-1-16/4 2136-1-16/3 21" 533 36" 914 0 n/a 25" 635 3730 949 65 29.5', 2424-1-16/4 2424-1-16/3 24" 610 24" 610 0 n/a 28" 711 25%" 645 60 27.2 2436-1-16/4 2436-1-16/3 24" 610 3& 914 0 n/a 28" 711 37W 949 68 30.8 Sinks with Double Drainboards 16 gauge type 430 stainless steel model # 2124-1-18-16/4 2424-1-24-16/4 16 gauge type 304 stainless steel model # 2124-1-18-16/3 2424-1-24-16/3 L 0 bowl dimensions width length in. mm in. mm 21" 533 24" 610 24" 610 24" 610 EAGLE GROUP 100 Industrial Boulevard, Clayton, DE 19938-8903 USA Phone: 302-653-3000 • Fax: 302-653-2065 www.eaglegrp.com Foodservice Division: Phone 800-441-8440 MHC/Retail Display Divisions: Phone 800-637-5100 dr ainboar d length quantity in. mm 2 18" 457 2 24" 610 overall dimensions width length in. mm in. mm 25" 635 60W 1530 28" 711 72A 1835 weight lbs. kg 99 44.9 108 49.0 Printed in U.S.A. 02012 by Eagle Group Rev. 05/12 Spec sheets available for viewiiig, printing or downloading from our online literature library at www.eaglegrp.com Although every attempt has been made to ensure the accuracy of the information provided, we cannot be held responsible for typographical or printing errors. Information and specifications are subject to change without notice. Please confirm at time of order. Rosseto EZ -SERV® H-50, 7 Gallon Wall Mount Dry Food Dispenser 27.75 x 6.3 x 22 (F... Page 1 of 3 About Us Contact Us Request Quote L �ON S n GEIRMIDMI Dining Room Kitchen Order Status Bar Enter item name or description General Supplies Office Supplies Dispos YOU ARE HERE: Home Restaurant Equipment and Supplies Restaurant Self -Serve Dispensers and Organizers Cereal and Bulk Food Dist Rosseto EZ -SERVO 0-0-5O, 7 Galion WaVO Mount Dry Food Dispenser X; Review this Item Product Code: ros-ers1197 Questions about this Product? `Like ! '380 ITEM 25 ROSSETO H50 Order Qty: 11 I Uld ADD TO MY FAVORITES Earn 866 Rewards Points for this item! Learn More... Usually Ships In 2-3 Business Days Description The EZ SERV H50 dry food dispenser by Rosseto is a five -cons stainless steel bracket. With tall and slender acrylic tubes, this 1 display and dispense approximately one ounce portions of anyt cream toppings. The clear acrylic tubes will create a striking an( inviting and interactive experience for customers. Stylish disper models are the leading ice cream topping dispenser and yogurt Portion control dial with soft, flexible paddle wheels Five 1.3 gal mounted metal adapter Containers keep contents fresh and rec protect cereal and snacks from breaking Stylish design adds to and useful display Ez Sery and Ez Pro Topping Dispensers cor lower topping costs while keeping your topping area clean Rost portioning; demand generating visual display; cost saving; hygit experience; stylish and functional; designed to increase your SE creates an engaging experience and increases customer satisfy Cream Toppings EZ SERV ice cream topping dispensers are 11 - dispensing toppings, making any ice cream shop or station eye Candy EZ SERV candy dispensers are the ultimate solution for making any candy shop or station eye-catching, interactive, anc end designs will add pizazz to any decor while providing unlimit designs will add pizazz to any decor while providing unlimited ft coffee bean and loose leaf tea dispensers are stylish, functiona shop. The crystal clear acrylic containers create a striking visua the dispensing area clean, and creating an interactive and engE coming back. Salad Toppings EZ SERV salad topping dispense These dispensers are meticulously built for dispensing dry sala Easily and hygienically dispense toppings either in self -serve SE topping dispensers in any establishment for an attractive, cost E SERV natural food dispensers are the finest way to store, displ: dried fruits, grains & more! Whether a countertop or wall mount, showcasing any product while promoting maximum product visi http://www.lionsdeal.com/ros-ers1197.html?utm source=[shopping]&utm medium=com... 11/16/2012 Rosseto EZPRO5W, 5 Gallon Wall Mount Dry Food Dispenser 26 x 7.75 x 15 (Five) 1 Bu... Page 1 of 2 About Us Contact Us Request Quote Order Status Dining Room Kitchen Bar Enter item name or description General Supplies Office Supplies Earn Rewards Account ITEM 25 Disposables On Sale [YOU ARE HERE: Home `. Restaurant Equipment and Supplies; Restaurant SetfServe Dispensers and Organizers ' Cereal and Bulk Food Dispensers :ros-ezp2890 Rosseto EZPRO5W, 5 Gallon Wall Mount Dry Food Dispenser 26 x 7.75 x 15 (Five) Review this Item Product Code: ros-ezp2890 Questions about thls Product? Like , 380] Related Items $639.90 Reg. price: $711.00 Savings: $71.10 (10%) Order Oty: Add To Cart 0 ® ADD TO MY FAVORITES Eam 640 Rewards Points for this item! Learn More... Usually Ships In 2-3 Business Days Shop By Business Description The EZ PRO 5W dry food dispenser by Rosseto is a five -container wall mounted dispenser, which Flawlessly hangs from a sleek stainless steel bracket. This five -container wall mount unit is ideal for any food station with limited counter space, yet with the demand for quality, design and functionality. The clear, one gallon containers beautifully showcase the products inside, creating an attractive and inviting visual display, perfect for ice cream & candy shops. This high-end dispenser offers a unique portion control mechanism, which reduces waste and lowers costs, while keeping your stations interactive. Approximate portion sizes include 1 oz. and 1 Tbs. portions. Rosseto has developed an advanced wall -mounted portioning system that also works as a storage container and dispenser for dry foods such as nuts, candy and coffee. The 19 L Five -Compartment EZ-SERVT- Wall Mount Dispenser - PRO Series (EZ-PRO5W) from Rosseto is as stylish as it is functional. This dispenser releases approximately one tablespoon per serving while five pre-installed clicking mechanisms keep foods moving. This model also includes five six -wing paddle wheels designed to dispense one ounce per serving as well as five regular dispenser nozzles. •Five removable label holders -Stainless steel lids & wall mount adapter -Six-wing paddle wheel in each container -Five concentrated nozzles with one inch opening -Five ergonomically -designed ABS containers allow for increased product selection -Dispenses approximately ane tbs per serving for improved portion control -Stylish design adds to any decor while transparent containers make a visual and useful display Ez Sery and Ez Pro Topping Dispensers control portioning, make a striking visual display and lower topping costs while keeping your topping area clean Rosseto's revolutionary portioning system: consistent portioning; demand generating visual display; cost saving; hygienic dispensing; convenient FIFO storage; interactive experience; stylish and functional; designed to increase your selling space while merchandising your product; creates an engaging experience and increases customer satisfaction; builds profitability into your service offering Ice Cream Toppings EZ SERV ice cream topping dispensers are the ultimate solution for tastefully displaying and dispensing toppings, making any ice cream shop or station eye-catching, interactive, and best of all, cost effective! Candy EZ SERV candy dispensers are the ultimate solution for tastefully displaying and dispensing bulk candy, making any candy shop or station eye-catching, interactive, and best of all, cost effective! Rosseto dispensers' high-end designs will add pizazz to any decor while providing unlimited functionality. Rosseto dispensers' high-end designs will add pizazz to any decor while providing unlimited functionality. Coffee & Tea Dispensers EZ SERV coffee bean and loose leaf tea dispensers are stylish, functional and a wonderful way to entice customers into any shop. The crystal dear acrylic containers create a striking visual display, while promoting product visibility, keeping the dispensing area clean, and creating an interactive and engaging experience for customers that keeps them coming back. Salad Toppings EZ SERV salad topping dispensers add functionality, color and flavor to any salad bar. These dispensers are meticulously built for dispensing dry salad toppings such as croutons, dry fruit, nuts & more! Easily and hygienically dispense toppings either in self -serve salad bars or in back -of -the -house. Integrate salad topping dispensers in any establishment for an attractive, cost effective, and user-friendly solution! Natural Foods EZ SERV natural food dispensers are the finest way to store, display, and dispense any natural food including nuts, dried fruits, grains & more! Whether a countertop or wall mounted unit, the tall, slender, dear containers are ideal for showcasing any product while promoting maximum product visibility and prolonging product freshness. Snacks EZ SERV snack dispensers are the greatest solution for dispensing nuts, pretzels, trail mix, and any other bar snack. The closed containers and dispensing mechanism prevent air and germs from seeping in and contaminating the product, ultimately extending the product life. In addition to keeping snacks fresh and hygienic, EZ SERV dispensers are fun to use, cost-effective and maintain the dispensing area dean. Cereal EZ SERV cereal dispensers add functionality, efficiency and zest to any breakfast buffet, cereal station, or private kitchen. These dispensers are meticulously built for dispensing dry cereal quickly and hygienically, while preventing product breakage or spills. In addition to their design and functionality, these dispensers are cost-effective & encourage healthy eating habits with their portion control dispensing mechanism. -Dimensions: 26 x 7.75 x 15 ORDERING $1000 OR MORE? 877-747-0111 CALL LS FOR SPECIAL PRICES AND DISCOUNTS } lr http://www.lionsdeal. com/ros-ezp2890.html?utm_source=[shopping] &utm_medium=co... 11/15/2012 ITEM NO. ITEM 26 RCP100, RCP200, RCP300, RCP400, RCP500, RCP600 Wells Refrigerated Cold Pans are self-contained units designed to hold pre -chilled products at serving temperature in a standard 12" x 20" pan. Each pan is thermostatically controlled and has a one -inch drain providing flexibility and convenience. Specifications Overall Dimensions: Inches MM Width RCP -100 RCP -200 RCP -300 RCP -400 RCP -500 RCP -600 Depth Height Weights: 17 3/8 31 44 3/4 58 1/2 72 1/4 86 25 3/8 23 441 787 1137 1486 1835 2184 645 584 Lbs. KG RCP -100 series: Installed Shipping RCP -200 series: Installed Shipping RCP -300 series: Installed Shipping RCP -400 series: Installed Shipping RCP -500 series: Installed Shipping RCP -600 series: Installed Shipping 84 89 176 182 187 194 250 258 269 278 240 340 38 40 80 83 85 88 113 117 122 126 109 154 Featu res • Drop-in, refrigerated cold pans are designed to hold pre -chilled products at serving temperature. • Each pan has a large 1 -inch drain located in the center for easy cleaning. • Self-contained unit comes with an ON/OFF switch and cordset for easy installation. • Air-cooled condensing unit has HFC -134a refrigerant, which is CFC free. • Fully insulated cold pans are refrigerated on both bottom and sides for greater efficiency. • Recessed top edge lowers inset pan, keeping food colder and fresher. • Each unit's interior and top is heavy gauge (18 gauge) stainless steel for maximum strength and durability. • Optional perforated bottom strainer plate conveniently holds ice above drain to avoid clogging. • NSF approved for holding bottled products and non -potentially hazardous foods. • The RCP series refrigerated cold pans are Underwriters Laboratories, Inc. LISTED and meet NSF International standards. • A warranty against defects covers parts for one year and labor for 90 days. An extended one-year labor and five-year compressor warranty is available at extra charge. Accessories / Options Perforated Bottom Strainer Plate, available for all models, contact factory Extended Warranty/Labor, one (1) year, WEL1 Extended Warranty/Labor, five (5) years, WEL5 LISTED STD.7 E162919 DIMENSIONS: INCH (MM) • MODELS RCP -100, RCP -200 DROP-IN BAIN MARIE WARMERS 19 7/8 25 3/8 (505) (645) 11 7/8 (302) 17 3/8 (441) 25 1/2 (648) 31 (787) RCP 100 RCP 200 3/4 (19) POWER SUPPLY CORD 18 (457) 9 (229) 1° NPT DRAIN CENTERED IN PAN RCP -100, RCP -200 ELECTRICAL SPECIFICATIONS: 14 (356) MODELS VOLTS WATTS HP AMPS PHASE POWER SUPPLY CORD RCP -100 115 460 RCP -200 115 460 1/6 4.0 SINGLE SUPPLIED 1/6 4.0 SINGLE SUPPLIED NOTE: Specifications are subject to change without notice. See installation instructions prior to installing the unit. This document is not for installation purposes. 03/02 REV(C) • PART NO. 49405 LISTED STD.7 E162919 DIMENSIONS: INCH (MM) 39 1/4 (997) 44 3/4 (1137) 53 (1346) 58 1/2 (1486) RCP -300, RCP -400 ELECTRICAL SPECIFICATIONS: MODELS VOLTS WATTS HP AMPS PHASE POWER SUPPLY CORD RCP -300 RCP -400 115 115 805 1/4 7.0 805 1/4 7.0 SINGLE SINGLE SUPPLIED SUPPLIED NOTE: Specifications are subject to change without notice. See installation instructions prior to installing the unit. This document is not for installation purposes. 03/02 • REV(C) • PART NO. 49405 LISTED STD.7 E162919 DIMENSIONS: INCH (MM) 1/4 (6) 66 3/4 (1695) 72 1/4 (1835) 80 1/2 (2045) 86 (2184) I3/4 (19) MODELS RCP -500, RCP -600 DROP-IN BAIN MARIE WARMER 1 _L 19 7/8 25 3/8 •Ir 1(505) (645) (356) T RCP 500 RCP 600 23 (584) POWER SUPPLY CORD 8 9 r (203) [ (229) (25) 24 (610) ~j f } 1" NPT DRAIN CENTERED IN PAN RCP -500, RCP -600 ELECTRICAL SPECIFICATIONS: MODELS VOLTS WATTS HP AMPS PHASE POWER SUPPLY CORD RCP -500 RCP -600 115 805 1/4 7.0 SINGLE 115 805 1/4 7.0 SINGLE SUPPLIED SUPPLIED NOTE: Specifications are subject to change without notice. See installation instructions prior to installing the unit. This document is not for installation purposes. WELLS MANUFACTURING COMPANY 2 ERIK CIRCLE, PO BOX 280, VERDI, NV 89439 U.S.A. USA PHONE: (775) 345-0444 • FAX: (775) 345-0569 FOR ORDERS ONLY: (888) 356-5362 • FAX: (800) 356-5142 www.wellsbloomfield.com ® 2002 WELLS MANUFACTURING • PRINTED IN THE U.S.A. 03/02 • REV(C) • PART NO. 49405 4::))we«s Steam Table Pan 1/6 Size, 4" D, Vollrath 30642 Horne » Cooking Equipment » Hot Food Tables » Steam Table Pans & Inserti Free shippi nginkb on mosttorder„s ovor $35o Item #: 30642 Reg. Price: 44-7-A0 Our Price: $12.61 Quantity: Browse all products by: Vollrath ADO f0 CAIN Description Description Have questions about this product? Shipping Info Reviews Related Items These "Super Pan II" steam table pan inserts are 1/6 size and 4" deep. It comes with reinforced corners and an anti -jamming design. For added strength and durability these pans are made from type 304, 18-8 stainless steel. Purchase a set of these st SERVER SERVE BETTER' ITEM 29 FOOD WARMERS: HOT TOPPING TWIN PUMP/LADLE Models Twin FS/FSP, Twin FSP & Twin FS TWIN FS/FSP 81290 V TWIN FS 81220 US LISTED Server MI _YEAR Made In the USA.) WARRANTY ALSO AVAILABLE FOR EXPORT TWO YEAR WARRANTY Server Products equipment is backed by a two-year limited warranty against defects in materials and workmanship. For a copy of our complete warranty statement, please refer to server-products.com. BID DESCRIPTION All stainless steel construction with a brushed (#4) finish. Each dispenses directly from (2) stainless steel jars or #10 cans (not included). (2) adjustable precalibrated thermostats control individual 500 watt heating elements. Temperature settings—marked on thermostat knobs—range from 100° F (38° C) to 200° F (93° C). Power is controlled with (2) ON/OFF rocker switches. The Twin FS/FSP is designed to pump and ladle hot toppings. Comes complete with a lift-off lid and 1 ounce (30 mL) 10" (25.4 cm) Ladle (82561). The pump features a rugged cast valve body and welded construction. Maximum stroke yields 1 ounce (30 mL). Gauging collars are supplied to reduce yield in 1/8 ounce (3.7 mL) increments. The Twin FSP is designed to pump (2) hot toppings. The Twin FS is designed to ladle (2) hot toppings. STANDARD FEATURES • All stainless steel construction for durability • Pump design prevents Toss of valve balls • Water fill line eliminates overflow accidents • (2) 500W heating elements for reliable heating & holding • Adjustable precalibrated thermostats for accurate heat control • Temperature marks on knobs with protective knob guard • Dispense directly from stainless steel jars or #10 cans • Pump stroke yields 1 oz (30 mL), now adjustable in 1/8 oz (3.7 mL) increments — allows for Portion OptimizationTM • (2) cleaning brushes included with pumps for maintenance ACCESSORY ITEMS ❑ 1 oz (30 mL) 10" (25.4 cm) Ladle 82561 ❑ 3 qt (2.8 L) Stainless Steel Jar 94009 SPECIFICATIONS ON REVERSE SIDE SERVER SERVE RET R- FOoOD 'WARMERS: HOOT TOPPONG TWN PUMP/LADLE Models Twin FS/FSP, Twin FSP & Twin FS TWIN FUDGE SERVER WITH PUMP AND LADLE 24.6 cm 43.2 cm SERVER MODELS TWIN FS/FSP 81290 TWIN FSP 81230 TWIN FS 81220 Lr Height 15 5/16' 38.9 cm 15 5/16" 38.9 cm 12 5/16" 31.3 cm Width 17" 17" 17" 43.2 cm 43.2 cm 43.2 cm Depth 13'/2' 13'/2" 131/2' 34.3 cm 34.3 cm 34.3 cm Weight 181b 191b 171b 8.2 kg 8.6 kg 7.8 kg Electrical 120V, 60Hz, 1000W, 8.3A, 72" (183 cm) cord set NEMA 5-15P, 15A, 120V PLUG Capacity (2) stainless steel jars or #10 cans hold 3 qt (2.8 L) each; 6 qt (5.7 L) total FOB RICHFIELD, WISCONSIN 53076 NSF LISTED AS A RETHERMALIZATION UNIT TO ENSURE FOOD IS QUICKLY HEATED TO A SAFE TEMPERATURE BEFORE BACTERIA HAS AN OPPORTUNITY TO GROW. if CAD LIBRARY Individual CAD images can be downloaded from our website. We are also a member of The KCL CADalog with more than 100 other manufacturers. Our complete collection of CAD files can be purchased through Kochman Consultants, Ltd. at kcicad.com. Server Products, Inc. 1 PO Box 98 1 Richfield WI 53076 1 800.558.8722 262.628.5600 1 F: 262.628.51101 spsales@server-products.com 1 server-products.com Server Products, Inc. reserves the right to modify specifications without obligation. Printed in USA 1.2012 Stock 02051 ADVANCE TABCO. SMART FABRICATION^ SPLASH MOUNTED FAUCETS 7 -PS -60 Wrist Handles 7 -PS -68 STAINLESS STEEL HAND SINKS 0 SPN STANDARD Item #: Qty #: Model #: Project #: Keyhole Bracket for easier installation and greater stability. FEATURES: One piece Deep Drawn sink bowl design. Sink bowl is 10" x 14" x 5". 7 -PS -45 sink bowl size is 16" x 20" x 8". 7 -PS -49 sink bowl size is 16" x 14" x 8" 7 -PS -50 IL 7 -PS -54 All sink bowls have a large liberal radii with a minimum dimension of 2" and are rectangular in design for increased capacity. Keyhole wall mount bracket. Stainless steel basket drain 1-1/2" IPS. Specific Features: 7 -PS -20 -NF deck mounted faucet ommitted. 7 -PS -50 features lever operated drain and built-in overflow with plastic overflow tube and spring clamps. P -Trap is 1 1/2". 7 -PS -54 features P -Trap only. P -Trap is 1 1/2". 7 -PS -20 4" O.C. deck mounted centerset faucet furnished with aerator. 7 -PS -67 7 -PS -20 7 -PS -20 -NF 7 -PS -50 & 7 -PS -60 4" O.C. splash mounted gooseneck faucet, chrome Faucet omitted plated & furnished with aerator. 7 -PS -45 Same as above plus 2 Support Brackets (Hardware Included). 7 -PS -67 features lever operated drain. SINGLE HOLE PUNCH DOUBLE HOLE PUNCH 7 -PS -68 4" O.C. splash mounted gooseneck faucet with Wrist Handles, chrome plated & furnished with aerator. DECK MOUNTED FAUCET Faucet omitted Features Large Size Sink Bowl 16"x20"x 8" Faucet omitted LARGE SIZE SINK BOWLS Features Large Size Sink Bowl 16"x14"x 8" CONSTRUCTION: All TIG welded. Welded areas blended to match adjacent surfaces and to a satin finish. Die formed Countertop Edge with a No -Drip offset. One sheet of stainless steel - No Seams. MATERIAL: Heavy gauge type 304 series stainless steel. Wall mounting bracket is Galvanized and of offset design. All fittings are brass / chrome plated unless otherwise indicated. MECHANICAL: Faucet supply is 1/2" IPS male thread hot and cold. Standard Faucet conforms to NSF 61 Standard 9. An optional faucet upgrade is required for compliance to AB 1953 Standards. For Replacement Faucets & Upgrades, Drains & Accessories visit our website at www.advancetabco.com Customer Service Available To Assist You 1-800-645-3166 8:30 am - 8:00 pm E.S.T. ®® Email Orders To: customer@advancetabco.com. For Smart Fabrication'" Quotes, Email To: smartfab@advancetabco.com or Fax To: 631-586-2933 ADVANCE TABCO. NEW YORK www.advancetabco.com GEORGIA Fax: (631) 242-6900 Fax: (770) 775-5625 TEXAS NEVADA Fax: (972) 932-4795 Fax: (775) 972-1578 B- 1 DIMENSIONS and SPECIFICATIONS TOL Overall: ± .500° Interior: ± .250° FITTINGS SUPPLIED AS SHOWN ALL DIMENSIONS ARE TYPICAL 7 -PS -20 15 lbs. 7 -PS -67 f- 171/4' --� 15 lbs. 15 1/4' Gooseneck 'Faucet 2" Lever Drain 31 lbs. Gooseneck ' Faucet 2" 1 °1 MMI!IIND `` 13' —al Gooseneck Faucet 2" 13" 31 lbs. TOP VIEW FOR: 7 -PS -50 17 1/4° 7 -PS -54 7 -PS -60 7 -PS -68 7 -PS -70 151/4" Sink Bowl 10" x 14" x 5" 7 -PS -50 & 7 -PS -54* NOTE: *7 -PS -54 Hand Sink Excludes Lever Drain and Overflow 13" 4 5" 1 15 lbs. *Lever Drain P -Trap Gooseneck Faucet Gooseneck Faucet 7 -PS -68 13 lbs. Gooseneck Faucet With Wrist Handles 8" 5" 7 -PS -70 3 5/8' 13' 7- 12 12 lbs. 7 -PS -71 Same as 7 -PS -70 with Single Hole Cutout Clk ADVANCE TABCO. 6MAFIT FA6R,CAT,GN- B-la 200 Heartland Boulevard, Edgewood, NY 11717-8380 ADVANCE TABCO is constantly engaged in a program of improving our products. Therefore, we reserve the right to change specifications without prior notice. © ADVANCE TABCO, NOVEMBER 2012 £RREao©ZL OPROWA L II109 INC. 441 Saw Mill River Road, Yonkers, NY 10701 (914) 476-9000 MODEL No: 0210 ISSUED: 1-87 REVISED: 7-99 SURFACE MOUNTED PAPER TOWEL DISPENSER 3/4' <194W TYP REF 11' (279m) 9 1/2' (24i.3rn) Ow T-- CD -- •-f1 \ - POINTING 'KEY' VALES CONCEALED REAR PANEL TYP 4 FRONT TOWEL GUIDES CDNTD4000S STAINLESS STEEL .../- PIACI] IN HINGE TUMBLER LOCK REFILL VIEWER SLOT - CL TOWEL SLOT 1 4' <102W 1-1/2' <38+n) - SIDE SPECIFICATION Surface Mounted Paper Towel Dispenser shall hold and dispense 525 standard multi -fold or 400 standard C -fold paper towels and shall be fabri- cated of alloy 18-8 stainless steel, type 304, /%1°22 gauge. All exposed surfaces shall be N24 satin finish and be protected during shipment with a PVC film easily removable after installation. Towel dispensing slot shall have a fully hemmed -in rolled edge for snag -free dispensing and user safety. Dispenser door shall be attached to the bottom of unit with a full length 3/16" dia. stainless steel multi -staked piano hinge and shall be held closed with a tumbler lock keyed alike to other ASI Washroom Equipment. Structural assembly of body and door components shall be of welded construction. Unit shall be provided with refill viewer slots on each side and shall have internal towel stack guides. Wall below unit shall be protected against uncontrolled door drop by self-limiting body and hinge construction. Back of unit shall have keyhole slots for hanging on pre- installed screws (by others). Surface Mounted Paper Towel Dispenser shall be Model NQ 0210 as manufactured by American Specialties, Inc., 441 Saw Mill River Road, Yonkers, New York 107014913 INSTALLATION Unit is surface mounted on wall or partition using five MO self tapping screws (supplied). Four mounting holes through back are "keyhole" slots for ease of installation on pre-installed screws. Center top mounting hole is horizontal slot for ease of adjustment and vandal resistant locking. For compliance with ADA Accessibility Guidelines, unit should be installed so that towel dispenser slot is 54" (1372 mm) maximum above finished floor (AFF) if clear floor side reach access is provided or 48" (1219mm) maximum AFF if clear floor forward reach access only is provided or 46" (1168mm) maximum AFF if side reach over an obstruction (vanity) is only provided. OPERATION Towels are self-feeding until supply is depleted. Unit may be refilled with a partial load in-place and will continue to feed properly. Low level of towel supply is indicated from 25% capacity to empty. Accessory Specialties AMERICAN DISPENSER Desert Rau Products C'yATROMBx. THIS MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES IN DESIGN OR DIMENSIONS WITHOUT FORMAL NOTICE ES 441 Saw MillAMERICAN River Road,americanspecialties. Yonkers, NYSPECI10701ALTI54716-9000 (914) 476-9000 INC . CS 711— www. com MODEL No: 0345 ISSUED: 7-05 REVISED: 6-06 SURFACE MOUNTED HORIZONTAL SOAP DISPENSER I cL HIHG® BILL CAP SIGHT GAUGE ALL PURPOSE LOU SILFIETTE LIDUID SOAP VALVE SPECIFICATION Surface Mounted Horizontal Soap Dispenser shall have a capacity of 40 fluid oz. (1.18 liter) of liquid or lotion soaps, synthetic detergents and antibacterial soaps containing PCMX and/or Triclosan. Dispenser shall be fabricated of 20 gauge stainless steel, alloy 18-8, type 304. All exposed surfaces shall be NQ 4 satin finish. Valve shall be constructed of a plastic valve body and push button with stainless steel and plastic internal parts. Valve operation shall comply with ADA Accessibility Guidelines by requiring no more than 5 lbsr (22.2 Newtons) pressure to actuate and require no grasping or twisting by operator. A tamper resistant sight gauge shall be provided. Unit shall have a hinged stainless steel refill door on top of unit, which is opened with special key provided. Surface Mounted Horizontal Soap Dispenser shall be Model NQ 0345 of American Specialties, Inc., 441 Saw Mill River Road, Yonkers, New York 10701-4913 INSTALLATION Unit is surface mounted to wall or partition with a wall mounting plate (supplied) and screws (by others). Unit is secured to interlocking wedge bracket and locked in place by a locking screw (supplied) installed through hinged refill door. Recommended installation for general utility is 42" (1066 mm) AFF or 6" (152mm) minimum above washbasin. OPERATION Push button to dispense soap. Unit is refilled through hinged door at top requiring special key (supplied) to open. Soap tank will continue to feed properly until soap level is below valve intake port. Tank supply is replenished manually on cycle determined by maintenance needs. Accessory Specialties AMERICAN DISPENSER Desert Ray Products givrmous THIS MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES IN DESIGN OR DIMENSIONS WITHOUT FORMAL NOTICE iPad POS 1 iPad Retail and Restaurant Point of Sale System Software 1 Restaurant POS Page 1 of 3 Watch Demo Revel Systems POS systemPoint of Sale for iPad Solution. More Information (Email phone jr-1Go Back • iPad • The App • Management Console • Hardware Forward • ❑ • Products • Demo • Buy • FAO • Press • Contact • Support Revel Systems' Point of Sale System Check out all the types of POS Revel has Click on one of the following to see more info on it: Mobile POS Food Truck POS http://revelsystems.com/products/ 11/21/2012 iPad POS 1 iPad Retail and Restaurant Point of Sale System Software 1 Restaurant POS Page 2 of 3 Frozen Yogurt POS QSR POS Coffee Shop POS Pizza POS Full Service POS Retail POS Grocery POS Revel Systems' POS System provides a complete front to back of house solution for restaurant and retail establishments. Regardless if you are a small business or a large enterprise, Revel Systems meets your needs today and grows with your changing needs tomorrow. App Feature List: Employee Login Each employee has a secure login that is different from managers. This allows owners to track not only when employees clock in and out but also what they do in the system. Order Taking The order taking process is simple; just choose your items from the categorized list and build the customer's order. Order Details Details about the order, such as item voids, deletions, special requests, discounts, holds, etc. are always available. Payment Processing Customers can pay using all major credit cards or gift cards and choose if they want receipts e-mailed or printed. Cook View / Expedite View http://revelsystems.com/products/ 11/21/2012 iPad POS 1 iPad Retail and Restaurant Point of Sale System Software 1 Restaurant POS Page 3 of 3 If you want to go completely paperless, orders can show up on the iPad in the Cook View rather than printed in the kitchen. An Expedite View is also available so servers can see what has been cooked and ready to be served. Back Office: Flexible Menu and System Configuration Customize the categories and items of your menu to suit your needs. You can also tailor the layout of receipts, specify tax rates to meet local requirements, set surcharges, set discounts and much more. Real-time Inventory Control As items and ingredients are sold, your inventory levels are automatically deducted and available for inventory count comparisons to quickly detect theft, loss or waste. Employee Scheduling and Reporting View metrics on employee data, such as work scheduled versus work performed, number of voids, discounts by employee, and employee productivity and sales volume. Real-time Reporting and Analytics Revel Systems provides a variety of reports to help you run your business, including sales summaries, transaction details, ingredients sold, and much more. Customer Relationship Management Acquire your customer's e-mail addresses from e-mailed receipts and export these addresses to a spreadsheet. © Revel Systems, Inc 2012 Address: 88 1st Street. 2nd Floor, San Francisco. CA 94105 Support: supportarevelsystems.com / 855-738-3555 Sales: sales(a%revelsystems.com / 855-738-3555 Business Development: BizDev(a,revelsystems.com e API • Remembering Steve e Careers o Contact TwitterFacebook Privacy Policy http://revelsystems.com/products/ 11/21/2012 Page 1 of 1 ® Dispensers Sold Separately C 0 Patents: 5,000,082, 5,331,885, 6,889,598, Other Patents Pending. International Patents Apply. The LUXUS® Thermal Dispenser is totally portable, and requires no electric power. Once filled and capped it goes anywhere...Ready to act as your remote dispensing station wherever needed. You can prepare them ahead of time and place them where you want them. It is important to note that the LUXUS® Thermal Dispenser can be staff -operated or used as a self-service system. Printed in USA 2006 ITEM NUMBER: MODEL CBS -51H15 SERIES 5000 The Ultimate Coffee Machine Your answer to brewing the best tasting coffee consistently day after day... Developed with proprietary designs and technologies, FETCO® equipment ensures safety and integrity of each brew with innova- tive designs such as: The Dual Brew Basket Safety Lock incorpo- rated into the start switch brews directly into our patented LUXUS® Thermal Dispenser to ensure a continuous flow of hot, aromatic, great tasting coffee. Stainless Steel Gourmet size baskets are designed for heavier brew ratios. FETCO® Brewers utilize the most recent technological advances in Coffee Brewing in order to... Hold a constant water temperature during 100% of brew cycle; maintain sprayover vol- ume consistency; resist lime buildup inside dispense tube system; and utilize all solid state components. Consultant & Contractor Approvals: FETCO® 600 Rose Road Lake Zurich, Illinois 60047 USA Phone: (847) 719-3000 Toll Free: (800) FETCO-99 FAX: (847) 719-3001 sales@fetco.com http://www.fetco.com MODEL CBS -51H-15 SERIES 5000 ELECTRIC IIPUT Ma 'WATER CDRKCTIOT rad. REAR Dimensions (Brewer): Height - 36" (914mm) Width - 12" (305mm) Depth - 20" (508mm) Dimensions (Shipping): Ships By Pallet Height - 35" (889mm) Width - 14 (356mm) Depth - 23" (585mm) Weight - 66 lbs (30 kg) ELECTRICAL FLECTRCAL CON"G. CODE NEATER COMM FOLIAGE PHASE WIRES SW MAX AMP MAW BATCHES PER HOUR COLO HOT WATER C51026 1x3.0 Kw 120/208 1 3+G 2.3 11 3 ;; 13f 7 8.6 120/220 2.6•. 120/240.S,11173"_0� tsifffitoi C51036 1x4.0 Kw 120/208 1 3+G '3:11 F)r4131 MINIM —1201220 _ .3..4' 1'5.8I165.8 11!Q 120/240 IT 41 , ; &CD 9U C51046• 2x3.0 Kw 1.V208 1 3+G''4 . 2Q:4• 1/4 M91) 1:20/220 5. LEWlap 00R 120/240. 1.41 F25I5111 �9y.9 419. e1 C51056m 2x4.0 kw 120/208 1 3+G 6M 11.9M [9?9s11k1!0 (T) RAM for TOS YAC meMzum. WATER RATER OWE T()NCPR I WATER PRESSURE. I PLOW RATE 3/8 MALE.FLARE_ 29.75 psi(' 00.5 OPT^. ACCESSORIES A006 Half Batch_ Brew' Basket (13" x 5") A009 Brewing'Stand For LS -15 (BS -1) -el A010 Alrpot Brewing A011 SingleSorving Station For LS -1$1.S5:10 1 4012 Twin Serving Station For LS•15'(SS2) '• A013 Triple Serving Station For LS•15 OPTIONS Z005 Color_Coded Dispenser Faucet Handles For D049 & D052 Orange Red, Blue, Gree k2StandgBiEfil For Dote & 0014 Orange (Standard Black'ji For D009 Orange, Rad, Blue, Green (Standard Bleb Z006 CBS 51H.15 Merit ima.Package ForTPD 1 _Ond� (Incl 2 x -A029, Flang Leas & Dispense'Tub'Ze F.bn gIj' Z007 CBS -52H-15 Maritime Package ForTPD=1T5�' M (Incl. 4 x A029, Flanged Legs & Dispense Tube�F.uanal. Z013 Iced Tea Brew Package,(Per Slda) : (Choice of 1.5G Dispenser BrewBaskettl'&rCo iTiol Z040 Step Down Transformer Z042 CBS--5-24-15-Universil al Wiring :ear (Field Covertlble from 1 to 3Phase) Z047 Red Handle On Braw Basket Z048 Green Handle On Brew Baskat • Z049 Orange Handle On Brew Basket Z055 Export -CIO -nage s Available �'P Z056 Three Phase Electrical t* Z058 'Water Sen&kivity_Se FFo_r_ReygrseQsnosis clookTorall FILTERS F00151/2"gl F002 13" x 5" Paper Fitters (500 Per Case) M". • A015 Roundbrip_Tray s" A029 TPD15 Maritime Brewer & Serve, Rlnp (l 1_Sft,)5 4039 In Line Water Filter With Cartrid a A069 IdentlfferPlates,Acryhc A075 Replacement Water Filter Cartrldne�,+;_ A082 Iced Tea Braw Basket (13" x 5'7 t . Yr3�r A097 Single Serving Station For L3S-15 (S3S5;5420 1. A098 Twln Serving Statlan For L3S-15;(S3S I5t2b' A099 TrlpleServing Station For L3S•15)(S3S15 20 A113 1,5 Gallon Hot Tea., f use r ' .: A129 Quad Serving Station For L3S-15 (83$1-Sr20 DISPENSERS D009 1.5 Gallon LUXUS®ThernialDis riser PD - D010 1.5 Gallon LUXUS®Thermal Dispenser''(LUr1ra7 D014 1;5 Gallon LUXU_S®Thermal;DisperserU(LSNtis D049 t.5 Gallon WXUSeThermal Dispnnser'(L30 1, ). 0052 15 Gallon LUXUS® Thermal 0lsponser FETCO® 600 Rose Road Lake Zurich, IL 60047-0429 USA Phone: (847) 719-3000 Toll Free: (800) FETCO-99 FAX: (847) 719-3001 sales@fetco.com http://www.fetco.com FETCO, LUXUS, Extractor, Pulse -Brew, Driven To Pioneer Innovation and product dress are all trademarks or registered trademarks of Food Equipment Technologies Company Printed in USA 2006 TAYLOR® BC10 >#andsrd 8 E112422 SP BW11 Manufactured by Vita -Mix® Corporation Models VM -0800, VM -0801, VM -0803, VM -0804 Five Year Warranty against defects. Item No. BC1 O/BW1 1 Razzle® Blender Features Simple to use. Dispense your soft serve ice cream directly into the serving cup. Attach the lid to the cup, add the desired mix -ins, blend and serve. Clean up is easy. The splash guard moves easily, and the sealed stainless steel housing wipes down quickly. Permanent Agitator. Blending the mix -ins with your soft serve ice cream is quick and easy. A separate agitator is available for hand dipped ice cream. Quiet. Blender operation is quiet. Brushless, ball bearing induction motor provides consistent product mixing. Counter or Wall Mount. Blender is available as BC10 to sit on the counter, or BW11 to mount on the wall or soft serve freezer (mounting bracket and drip tray are included). Foot Control. Guarded foot control for hands-free operation of blender. Razzle® Program Materials Cups and Lids Razzle® cups and lids are available by the case (1,000 per case) 051967 12 fl. oz. (355 ml) 051968 16 fl. oz. (475 ml) 051969 Domed lids fit both sizes of cups. Allows for blending with virtually no splattering. X52080 Organizer X52080 Organizer Conveniently holds lids and two sleeves of Razzle cups. For counter or wall mount: template and hardward included. Width: 16 in. (406 mm) Height 20 in. (508 mm) Depth: 4 in. (102 mm) Consult your local Taylor distributor for additional merchandising materials for a complete Razzle program. Rockton, Illinois 61072 800-255-0626 Phone 815-624-8333 Fax 815-624-8000 www.taylor-company.com e-mail: info@taylor-company.com International Office Taylor Company S.r.l. Roma, Italy Tel: +39-06-420-12002 Fax: +39-06-420-12034 e-mail: romeoff@taylor-company.com ISO 9001:2000 Registered Firm BC1 0/BW1 1 Razzle0 Blender X52037-1 X52078-1 X52566-1 X53407-1 X53492-2 Part Number X52037-1 X52037-2 X52078-1 X52078-2 X52566-1 X52566-2 X52566-3 X53407-1 X53492-1 X53492-2 Standard bins 2 4 2 --- 2 4 --- 2 --- 1 High volume bins 2 --- --- 2 2 4 1 --- Width - inches 14 14 14 14 29-1/4 29-1/4 29-1/4 10 6-5/16 6-5/16 Width (mm) 356 356 356 356 743 743 743 254 160 160 Height - inches 34 32 20 20 19-1/4 16 19-1/4 20 18-11/16 16-1/16 Height (mm) 864 813 508 508 489 406 489 508 475 408 Depth - inches) 6 6 6 6 6 6 6 6 6 6 Depth (mm) 152 152 152 152 152 152 152 152 152 152 Mount on Wall Wall Counter or Wall Counter, Wall or Hood"* Wall Wall Wall BC10 BW11 BC10 BW11 Weights lbs. kgs. Net 17 17 7.7 7.7 Crated 26 21 11.8 9.6 cu. ft. cu. m. Volume 1.9 1.1 0.05 0.03 Dimensions In. mm. Width 10 7-1/4 254 184 Depth 9 8 229 203 Height 24 17 610 432 Electrical Total Supplied Amps with NEMA Cord 120/50/60/1 2.6 5-15P 220-240/50/1 1.3 ... International cord specifications vary. This unit may be manufactured in other electrical characteristics. Refer to the local Taylor Distributor for availability. (For exact electrical information, always refer to the data label of the unit.) Bidding Specs Electrical: Volt Hz ph Neutral: n Yes ❑ No I Cooling: ❑ Air ❑Water ❑ NA Options: Dispensers Portion controlled mix -in dispenser kits are available in several configurations. Dispensers may be mounted on the wall, counter, or soft serve freezer. Kits contain mix -in containers, mounting bracket, template and hardware. (See photos and chart above for further details. Other dispensers may be available.) Options 051750 Mixing Collar Plastic collar may be used in place of the domed lid. 051498 Agitator for Hard Ice Cream An agitator for hard ice cream is available. Simply replace the agitator for soft serve or frozen yogurt with the agitator designed for blending hand -dipped ice cream. Continuing research results in steady improvements; therefore, these specifications are subject to change without notice. .1116 AMI � TAYLOR' Taylor Company, A Division of Carrier Commercial Refrigeration, Inc. Rockton, Illinois 61072 815-624-8333 800-255-0626 Fax 815-624-8000 www.taylor-company.com Printed in U.S.A. 052178 -ADV 6/05 t\ ADVANCE TABCO. SMART FABRICATION'. STAINLESS STEEL DROP-IN SINKS One Compartment - FOR HAND SINK USE Sinks Includes Gooseneck Faucet & Drain Item #: Qty #: Model #: Project #: FEATURES: One piece seamless Deep Drown sink bowl design. All sink bowls have a large liberal radii with a minimum dimension of 2" and are rectangular in design for increased capacity. Self -Rim Design. Mounting clips provided accomodate all thicknesses of counter. (Quantity supplied varies based on drop in sink ordered). Includes 4" O.C. K-52 faucet & basket drain. CONSTRUCTION: Unit fabricated from one sheet of stainless steel. All bowls are Sound Deadened. Units feature Advance Tabco's Smart Finish'T'. MECHANICAL: Faucet supply is 1/2" IPS male thread. Deck mounted faucet is furnished with aerator and 4" O.C. MATERIAL: 20 gauge type 304 series stainless steel. Faucets are brass -nickel plated. Stainless Steel 1-1/2" IPS basket drain. STANDARD MOUNTING CLIPS accomodate all thicknesses of counter. Replacement # K-28 (Per Sink) Available Faucets & Accessories Model # Qty Deck Mounted 3 1/2" Gooseneck. 4" 0.C. K-52 Deck Mounted 8 1/2" Gooseneck. 4" 0.C. K-55 Deck Mounted Swing w/Spray. 8" 0.C.* K-58 Deck Mtd. X.H.D. 3 1/2" Gooseneck. 4" 0.C. K-62 Mounting Clips (Bag of 4). K-28 *REQUIRES K-472 FAUCET HOLE REVISION DI -1-5 DI-1-5SP New 6" Rear & Side Splash DI -1-1 OSP DI -1-25 DI -1-10 DI -1-35 Standard Faucet conforms to NSF 61 Standard 9. An optional faucet upgrade is required for compliance to AB 1953 Standards. For Replacement Faucets & Upgrades, Drains & Accessories visit our website at www.advancetabco.com Customer Service Available To Assist You 1-800-645-3166 8:30 am - 8:00 pm E.S.T. ® Email Orders To: customer@advancetabco.com. For Smart Fabrication" Quotes, Email To: smartfab@advancetabco.com or Fax To: 631-586-2933 ADVANCE TABCO. NEW YORK GEORGIA TEXAS NEVADA www.advancetabco.com Fax: (631) 242-6900 Fax: (770) 775-5625 Fax: (972) 932-4795 Fax: (775) 972-1578 A-1 TOL ± .125" DIMENSIONS and SPECIFICATIONS Supplied with K-52 Faucet ALL DIMENSIONS ARE TYPICAL DI -1-5 5. Approx. Wt. 12 lbs. DI-1-5SP _L 6" T Approx. Wt. 16 lbs. DI -1-10 10° q. Approx. Wt. 14 lbs. Faucet L-10 1/2" Z' DI-1-10SP 1 Ti IF 10" LL Approx. Wt. 18 lbs. TOP VIEW FOR TOP VIEW FOR DI -1-5 & DI -1-10 DI-1-5SP & DI-1-10SP 0. —.. 14" _4 13' Cut -Out Size 12 1/4" x 18 1/4" 1 1/4" radius corners f 00 41 O- 14" I ° I— 1 3" —1 DI -1-25 14' 12" LL Approx. Wt. 8 lbs. Faucet - 1 ----- Cut -Out Size 11 1/4" x 13 1/4" 11/4" radius corners DI-1-35 15" e 17" Approx. Wt. 10 lbs. Cut -Out Size 16 1/4" x 14 1/4" 1 1/4" radius corners Faucet --\\ TYPICAL INSTALLATION OVERALL DIMENSION (0.D) CUTOUT DIMENSION (0.D -3/4") Cut -Out Size = L to R x F to B A- la AC.:211 ADVANCE TABCO. 200 Heartland Boulevard, Edgewood, NY 11717-8380 ADVANCE TABCO is constantly engaged in a program of improving our products. Therefore, we reserve the right to change specifications without prior notice. © ADVANCE TABCO, JUNE 2012 APPLICATION: PRODUCT NAME: 4" C/C DECK FAUCET JOB NAME: QUANTITY: ITEM NO.: r[8" (MAX) 203.2mm]� 2" [50.8mm] L 4"�I [101.6mm FOOTPRINT: 5 3/4" [146.3mm] 1/2" SLIP JOINT 1 7/8" MODEL DIM "A" DIM "B" DIM "C" 3516 8-1/2" [215.9mm] 12-1/2" [317.5mm] 5-1/2" [139.7mm] 3526 4-3/4" [120.7mm] 8-3/8" [212.7mm] 3-1/2" [88.90mm] ROUGH -IN: • L 4"�I [101.6mm - 07/8" [22.2mm] O SPECIAL CONFIGURATION (CHECK BASE MODEL AND OPTIONS) MODEL: ❑ 3516 W/ 12" RIGID GOOSENECK SPOUT ❑ 3526 W/ 6" RIGID GOOSENECK SPOUT OPTIONS OR MODIFICATIONS: ❑ SUPPLY LINES (24" OR 36") CIRCLE LENGTH O VANDAL RESISTANT KIT o HANDLES (CROSS OR WRIST) CIRCLE STYLE ❑ OTHER FEATURES: * 4" C/C DECK MOUNT * SWIVELING SEAT DISKS * HOT SIDE STEM - RIGHT HAND * COLD SIDE STEM - LEFT HAND * STAINLESS STEEL SEATS * STAINLESS STEEL SEAT SCREWS * STAINLESS STEEL HANDLE SCREWS * 1/2" SLIP JOINT KIT SYSTEM LIMITS * TEMP: 40°F MIN. TO 140°F MAX. * PRESSURE 200 PSI MAX. STATIC * 2.20 GPM AT 80 PSI SHIPPING WEIGHT * 4.5 LBS SA ANSI/A112.18.1M, ANSI/NSF 61.9 FISHER MANUFACTURING COMPANY TOLL FREE: 800-421-6162 - FAX: 800-832-8238 information@fisher-mfg.com - www.fisher-mfg.com 0 'A32J 919E '33dS F.1 ICEU15O - SELF CONTAINED CUBE ICE MAKER ICEU15O OO U15O - SELF CONTAINED CUBE OOL MAKER Air and Water Cooled A. Ice maker water in 3/8" FPT. B. Bin and ice maker drain, 3/4 FPT. C. Hole for electrical connections, 7/8". D. Condenser water in, 3/8" FPT (water cooled units only). E. Condenser water out, 1/2" FPT (water cooled units only). Air Out -Front 39" (991 mm) 24"� (610mm) 24" (610mm) Air In -Front Operating Requirements Ice -O -Matic Ice. Pure and Simple- 2.6" imple 2.6' (67 mm) 16.9' (106 mm) 33" (838 mm) 6" (152 mm) to 7" (178 mm) Adjustable Leg =MO MIDOE:a W%D%N(in.) 60 Hz Ambient Temp. Range Air 50"F (10'C) 1oo'F (38"C) Water Temp. 40"F (4.4"C) Water Pressure 20 PSIG (1.4 BAP) 6o PSIG (4.1 BAP) Specifications 9.6" (243 mm( — f 6' (152 mm) Dimensions 6' (152 mm) 9° (229 mm) 30" (764 mm) Front & Pear View r , eiiii,M2C312/ W%D%N(in.) 24x24x39 WxDxk(mm) 610x610x991 C(rj�{j. = ro. le�;1 OM ProductionC222:17a1W gillazzArpootaDgecgto Q31$ =Used pertblbs Cj/ co t$j% SIZEPIZU Voltage Characteristics M02'• aVl22. IIID (n Approx. BTUs (IACEliF° j24hrs ' r�� (tad Potable ICEU150A* Air 174 (79) 112 (51) 34.0 - 11.8 115/60/1 9.7 15 3.572 ICEUl5OW Water 144 (65) 32.2 152 8-o 79 3.569 NOTES: Number of Wires: 3 (including ground) Approx. Shipping Weight lbs (kg): ICEU15OA 160 (73) • ICEUI5OW 160 (73) Refrigerant Type: R404A ""BTUI-1 is calculated 0°F Evaporator, /00°F Condensing, and 33 PS1G. *ENERGY STAR qualified machine. Please see our website www.iceomatic.com for the latest list of ENERGY STAR qualified machines and available rebates 11100 E. 45th Avenue • Denver, CO 80239 • Phone: 1. 866. PURE. ICE • Fax: 303. 371. 6296 • www.icaomatic.com Rev: 06/10 Part: 1001 EQUIPMENT SPECIFICATIONS Counter Footprint 9"w x 9"d x 17"h Manufacturer Warranty 13, 15, 18 amp models - 2 years/15,000 cycles 20 amp model - 3 years/20,000 cycles The Choice of Blending Professionals. Known in the blending industry as the gold standard for commercial blenders, the Blendtec Smoother has consistently delivered improved taste and texture to frozen drinks, coffees, smoothies and ice cream programs for more than a decade. Designed for ultimate versatility, the Smoother can be utilized for both above -counter and in -counter operations. The Smoother combines power with intelligence and beauty. Standard Features The Smoother can be fitted with Q -Series components for sound reduction • POWER • Available in 13, 15, 18, or 20 amp models • Direct drive motor • VORTEX • Two 64oz. jars included • Milkshake blade on 64 oz. jar available • 96 oz. five -sided jar available Additional Options • DISPENSE CONTROLS • No-TendTM touchpad controls o 30 pre-programmed blend cycles to choose • Blue LCD display counts cycles • Solid state electronics In CUSTOMIZE o Combine with our D8 dispenser machine for a total solution It endtec® 1206 South 1680 West Orem, UT 84058 801-222-0888 ° 1-800-BLENDTEC www.blendtec.com • Custom jar graphics available • Program your own blend cycles from your computer • QUIET e Q-SeriesTM sound components are compatable with Smoother models and reduce apprent sound up to 50 percent. �aa�a c i us NSF CERTIFIED MKT -082 Smoother Brochure Rev.01 05/06 /FEDERAL. a Stande�t company Item CONVERTIBLE SERVICE OVER REFRIGERATED SELF -SERVE SPECIALTY MERCHANDISER MODEL SSRC3652 SSRC5052 SSRC5952 SSRC7752 Display a variety of products and serve more customers with presentation and value in mind. Cases are available in lengths of 36", 50", 59", and 77". STANDARD FEATURES Refrigerated Self -Serve Bottom Display - Steel base construction with black exterior. Other finishes optional. - Black interior, mirrored end panels. - Horizontal shielded top light. - Two-tier black display step. - Thermometer. - Condensator evaporator provided for a totally self-contained system. - Easy clean, rustproof insulated evaporator coil compartment. - Easily accessible light switch and adjustable power switch. - Average case temperature of 38° to 40°F is maintained. - Rear access to the refrigeration system for quick and easy service. - R404 Refrigerant. - Adjustable leg levelers. Service Top Display - Divided merchandise area. 3' only has one display area. - Baffle system converts display from non -refrigerated to refrigerated. - Clear glass rear sliding doors. - Tempered lift -up thermopane front glass. - Adjustable black wire shelf. - Shielded top and shelf light. - Thermometer. CONVERU ItILE S ERVW E OVER REFRIGERATED SELF -SERVE O PTIONALACCESS®RIES: JFor Self -Serve Refrigerated Base * Special Finish * Energy -Saving Night Curtain * Security Night Cover * Solid Rear Sliding Access Doors * Cord & Plug * Remote Refrigeration * Casters or Legs * Lighted Black Wire or Glass Shelf in Lieu of Display Steps * Rear Wrapping Board JFor Service Top Display * Reflective Rear Doors * Glass Shelves ELECTRICAL BOX CONNECTION 15.5 52.4 52.0 15.5 OPTIONAL BOTTOM SHELF W/LIGHT SPECIFICATIONS: STANDARD STEP PANS Model Dimensions L W H Shipping Weight (lbs) Shelf Area (Sq. Ft.) *Self -Contained with Condensate Pan Remote 120/60/1 with Condensate Pan SSRC3652 36" x 34" x 52" ? ? 120/60/1 - 1/3 HP - 15 AMPS 10 AMPS SSRC5O52 50" x 34" x 52" ? ? 230/60/1 - 1/2 HP - 10 AMPS 10 AMPS SSRC5952 59" x 34" x 52" ? ? 230/60/1 - 1/2 HP - 12 AMPS 12 AMPS SSRC7752 77" x 34" x 52" ? ? 230/60/1- 3/4 HP - 13 AMPS 12 AMPS - Refrigerated cases are designed to operate in a maximum environment of 75° F ambient and 55% relative humidi y. - Due to continuing engineering improvements, specifications are subject to change without notice. Look to Federal for Innovative Merchandising Federal Industries A Standex Company 215 Federal Avenue Belleville WI 53508-0290 Phone: 800-356-4206 Do8p ;-=Standex3mPe�v Fax: 608-424-3234 Email: geninfo@federalind.com Web Site: www.federalind.com /tom Mll, '""rinizaleiffr TRUE FOOD SERVICE ® EQUIPMENT, INC. 2001 East Terra Lane • O'Fallon, Missouri 63366 (636)240-2400 • Fax (636)272-2408 • (800)325-6152 • Intl Fax# (001)636-272-7546 Parts Dept. (800)424 -TRUE • Parts Dept. Fax# (636)272-9471 • www.truemfg.com Model: TUC -48G Undercounter: Glass Door Refrigerator Project Name: Location: Item #: Qty: Model #: AIA # SIS # ROUGH -IN DATA TUC -48G 1 True's undercounter units are designed with enduring quality that protects your long term investment. Designed using the highest quality materials and components to provide the user with colder product temperatures, lower utility costs, exceptional food safety and the best value in today's food service marketplace. 1 Oversized, environmentally friendly (134A) forced -air refrigeration system holds 33°F to 38°F (.56°C to 3.33°C). All stainless steel top and ends. Matching aluminum finished back. 1 Front breathing. Energy efficient, "Low -E', double pane thermal insulated glass door(s). 1 Heavy duty PVC coated wire shelves. (t Foamed -in-place using Ecomate. A new, innovative, high density, polyurethane insulation that has zero ozone depletion potential (ODP) and zero global warming potential (GWP). Specifications subject to change without notice. Chart dimensions rounded up to the nearest Ye" (millimeters rounded up to next whole number). t Depth does not include 1" (26 mm) for rear bumpers and'ro" 4 mm) fo door handle. • Height does not include 61" ( 59 mm) for castors or 6" (153 mm) for optional legs. ♦ Plug type varies by country. OC E �VL� NSf. APPROVALS: Printed in U.S.A. AVAILABLE AT Model: TUC -48G Glass STANDARD FEATURES DESIGN • True's commitment to using the highest quality materials and oversized refrigeration systems provides the user with colder product temperatures, lower utility costs, exceptional food safety and the best value in today's food service marketplace. REFRIGERATION SYSTEM • Factory engineered, self-contained, capillary tube system using environmentally friendly (CFC free) 134A refrigerant. • Oversized, factory balanced refrigeration system with guided airflow to provide uniform product temperatures. • Extra large evaporator coil balanced with higher horsepower compressor and large condenser; maintains cabinet temperatures of 33°F to 38°F (.5°C to 3.3°C) for the best in food preservation. • Sealed, cast iron, self-lubricating evaporator fan motor(s) and larger fan blades give True undercounter units a more efficient, low velocity, high volume airflow design. This unique design ensures faster temperature recovery and shorter run times in the busiest of food service environments. • Condensing unit access in back of cabinet, slides out for easy maintenance. CABINET CONSTRUCTION • Exterior - stainless steel top and ends. Matching aluminum finished back. • Interior - attractive, NSF approved, white aluminum liner. 300 series stainless steel floor with coved corners. • Insulation - entire cabinet structure is foamed - in -place using Ecomate. A new, innovative, high density, polyurethane insulation that has zero ozone depletion potential (ODP) and zero global warming potential (GWP). PLAN VIEW CUBIC FEET ' 1-2---- .-Based 2•Based on ANSI/AHAM HRF-1-2004 o 5" (127 mm) diameter stem castors - locks provided on front set. 36" (915 mm) work surface height. DOORS • "Low -E", double pane thermal insulated glass assembly with extruded aluminum frame(s). o Each door fitted with 12" (305 mm) long extruded aluminum handle. o Positive seal self-closing door(s). Door(s) swing within cabinet dimensions. o Magnetic door gasket(s) of one piece construction, removable without tools for ease of cleaning. SHELVING o Four (4) adjustable, heavy duty PVC coated wire shelves 219/6"L x 16"D (548 mm x 407 mm). Four (4) chrome plated shelf clips included per shelf. o Shelf support pilasters made of same material as cabinet interior; shelves are adjustable on '/2" (13 mm) increments. LIGHTING o Fluorescent interior lighting. MODEL FEATURES • Evaporator is epoxy coated to eliminate the potential of corrosion. • NSF -7 compliant for open food product. ELECTRICAL • Unit completely pre -wired at factory and ready for final connection to a 115/60/1 phase, 15 amp dedicated outlet. Cord and plug set included. 141 48'/16 p (1228 mm) 7 0563r Elevation Right // 3D Back TUC -48G TFQZ46E OIL ,25/4" 115/60/1 NEMA -5-1 5R 4" nm) 3515/16" (913 mm) (321 mm) )"4 195/B" M (499 mm) t63/ 6' ELEVATION VIEW (158 mm) WARRANTY One year warranty on all parts and labor and an additional 4 year warranty on compressor. (U.S.A. only) METRIC DIMENSIONS ROUNDED UP TO THE NEAREST WHOLE MILLIMETER SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 521/a" (1324 mm) 511/8' (1299 mm) 305132- (766 mm) 301/16" 211/16" (535 mm) OPTIONAL FEATURES/ACCESSORIES Upcharge and lead times may apply. ❑ 230-240V/50 Hz. ❑ 6" (153 mm) standard legs. ❑ 6" (153 mm) seismic/flanged legs. ❑ 21/2" (64 mm) diameter castors. ❑ Single overshelf. LI Double overshelf. ❑ TUC -27 Stacking collar. ❑ 30" (762 mm) deep,'/2" (13 mm) thick, white polyethylene cutting board. Requires"L" brackets. ❑ 30" (762 mm) deep,' " (13 mm) thick, composite cutting board. Requires "L" brackets. ❑ Heavy duty, 16 gauge tops. ❑ Exterior rectangular digital temperature display (factory installed). ❑ ADA compliant models with 34" (864 mm) work surface height. ❑ Low profile models with 317/8" (810 mm) work surface height. ❑ Remote cabinets (condensing unit supplied by others; system comes standard with 404A expansion valve and requires R404A refrigerant). Consult factory technical service department for BTU information. All remote units must be hard wired during installation. 3/32 (3 mm) (764 mm) 1( (26 nn4 25/16' (59 mm) umir 37/8" VI r (99 mm) RIGHT VIEW rgit Model Elevation Right Plan 3D Back TUC -48G TFQZ46E TFQZ46S TFQYO2P TFQZ463 4113MI;: FOOD SLDaVOCL L@2MDIPOv1)LOJ4 2001 East Terra Lane • O'Fallon, Missouri 63366 • (636)240-2400 0 Fax (636)272-2408 • (800)325-6152 0 Intl. Fax# (001)636-272-7546 • www.truemfg.com "srusisizim TRUE FOOD SERVICE EQUIPMENT, INC. 2001 East Terra Lane • O'Fallon, Missouri 63366 (636)240-2400 • Fax (636)272-2408 • (800)325-6152 • Intl Fax# (001)636-272-7546 Parts Dept. (800)424 -TRUE • Parts Dept. Fax# (636)272-9471 • www.truemfg.com Model: TWT -48 Worktop: Solid Door Refrigerator Project Name: Location: Item #: Qty: Model #: AIA # 5,5 # ROUGH -IN DATA TWT -48 / True's worktop units are designed with enduring quality that protects your long term investment. / Designed using the highest quality materials and components to provide the user with colder product temperatures, lower utility costs, exceptional food safety and the best value in today's food service marketplace. / Oversized, environmentally friendly (1 34A) forced -air refrigeration system holds 33°F to 38°F (.5°C to 3.3°C). / All stainless steel front, top and ends. Matching aluminum finished back. Top and backsplash are one piece formed construction. Bacteria and food particles cannot be trapped underneath as with other two- piece worktop units. / Front breathing. Heavy duty PVC coated wire shelves. Foamed -in-place using Ecomate. A high density, polyurethane insulation that has zero ozone depletion potential (ODP) and zero global warming potential (GWP). Model: TWT -48 STANDARD FEATURES DESIGN • True's commitment to using the highest quality materials and oversized refrigeration systems provides the user with colder product temperatures, lower utility costs, exceptional food safety and the best value in today's food service marketplace. REFRIGERATION SYSTEM • Factory engineered, self-contained, capillary tube system using environmentally friendly (CFC free)134A refrigerant. • Oversized, factory balanced refrigeration system with guided airflow to provide uniform product temperatures. • Extra large evaporator coil balanced with higher horsepower compressor and Targe condenser; maintains cabinet temperatures of 33°F to 38°F (.5°C of 3.3°C) for the best in food preservation. • Sealed, cast iron, self-lubricating evaporator fan motor(s) and larger fan blades give True worktop units a more efficient, low velocity, high volume airflow design. This unique design ensures faster temperature recovery and shorter run times in the busiest of foodservice environments. • Condensing unit access in back of cabinet, slides out for easy maintenance. CABINET CONSTRUCTION • Exterior - stainless steel front, top and ends. Matching aluminum finished back. Top and backsplash are one piece formed construction. Bacteria and food particles cannot be trapped underneath as with other two-piece worktop units. • Interior -attractive, NSF approved, white aluminum liner. Stainless steel floor with coved corners. PLAN VIEW 335 16' (847 mm) • Insulation - entire cabinet structure and solid doors are foamed -in-place using Ecomate. A high density, polyurethane insulation that has zero ozone depletion potential (ODP) and zero global warming potential (GWP). • 5" (127 mm) diameter stem castors - locks provided on front set. 36" (915 mm) work surface height. DOORS • Stainless steel exterior with white aluminum liner to match cabinet interior. • Each door fitted with 12" (305 mm) long recessed handle that is foamed -in-place with a sheet metal interlock to ensure permanent attachment. • Positive seal self-closing door(s) with 90°stay open feature. Door(s) swing within cabinet dimensions. • Magnetic door gasket(s) of one piece construction, removable without tools for ease of cleaning. SHELVING • Four (4) adjustable, heavy duty PVC coated wire shelves 219/16"L x 16"D (548 mm x 407 mm). Four (4) chrome plated shelf clips included per shelf. • Shelf support pilasters made of same material as cabinet interior; shelves are adjustable on 1/2" (13 mm) increments. MODEL FEATURES • Evaporator is epoxy coated to eliminate the potential of corrosion. • NSF -7 compliant for open food product. 485/16° (1228 mm) 39/16' (91 mm) 293/4' (756 mm) 391/2' (1004 mm) 3515/16' 5' (127 mm) 125/a (321 mm) 195/8° ELEVATION (499 mm) WARRANTY One year warranty on all parts and laborand an additional 4 year warranty on compressor. (U.S.A. only) (913 mm) 67/18- (158 mm) METRIC DIMENSIONS ROUNDED UP TO THE NEAREST WHOLE MILLIMETER SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 5217/32" 2119/32 (546 mm) ELECTRICAL • Unit completely pre -wired at factory and ready for final connection to a 115/60/1 phase, 15 amp dedicated outlet. Cord and plug set included. 115/60/1 NEMA -5-1 5R OPTIONAL FEATURES/ACCESSORIES Upcharge and lead times may apply. ❑ 230 - 240V / 50 Hz. 0 6" (153 mm) standard legs. ❑ 6" (153 mm) seismic/flanged legs. ❑ 21/2" (64 mm) diameter castors. 0 Barrel locks (factory installed). Requires one per door. ❑ Single overshelf. ❑ Double overshelf. 0 281/4" (718 mm) deep, Y" (13 mm) thick, white polyethylene cutting board. Requires"L" brackets. 0 281/4" (718 mm) deep, Y" (13 mm) thick, composite cutting board. Requires "L" brackets. 0 Heavy duty, 16 gauge tops. 0 Exterior rectangular digital thermometer (factory installed). 0 ADA compliant models with 34" (864 mm) work surface height. 0 Remote cabinets (condensing unit supplied by others; system comes standard with 404A expansion valve and requires R404A refrigerant). Consult factory technical service department for BTU information. All remote units must be hard wired during installation. (1335 mm) 30416' (764 mm) RIGHT VIEW AModel 110.7 Elevation Right Plan 3D Back TWT -48 TFPY02E TFPY025 TFPY02P TFPY023 4[EM[E [FOOD SSIERUTCE [ UM:DR]IEGd)4 2001 East Terra Lane 0 O'Fallon, Missouri 63366 • (636)240-2400 • Fax (636)272-2408 • (800)325-6152 • Intl. Fax# (001)636-272-7546 • www.truemfg.com WELLS BLOOMFIELD /WAFFLE BAKERS WB -2 WB -I WB -2 Wells WB- I and WB -2 Waffle Bakers provide versatility and ease if use. upper grid to rise evenly as the waffle expands during cooking. Each Features Specifications Elements are controlled by a factory pre-set precision thermostat. • Grids are seven-inch diameter, die-cast aluminum with a tapered pattern and lipped edge. • Floating hinge allows upper grid to rise evenly as the waffle expands during cooking. • Stainless steel front, top and sides provide maximum strength and durability. • Front -mounted adjustable mechanical bell time assures consistent waffle color. • The WB -2 has two lighted rocker ON/OFF switches to allow independent operation of each baking unit. • Die -stamped stainless steel drip tray removes easily for cleaning. unit has a floating hinge to allow the Overall Dimensions: Inches MM WB -1 Width Depth Height WB -2 Width Depth Height 10 1/8 257 13 1/2 342 8 3/4 222 19 13/16 13 1/2 8 3/4 503 342 222 Pre -Heat Time: 8 minutes Typical Production: Per Hour WB -1 WB -2 24 48 Weights: Lbs. KG • Handles are nickel -plated steel with an open -coil WB -1 design for minimal heat transfer. Installed • The WB -1 and WB -2 Waffle Bakers are Shipping Underwriters Laboratories, Inc. Listed and meets WB -2 NSF International standards. Installed 25 I I • A one-year warranty against defects covers parts Shipping 27 12 and labor. 13 6 14 7 Accessories/Options Replacement drip tray, 21489 LISTED E6070 WB -1 SINGLE BAKER WB -2 DUAL BAKER STD.4 131/2 343 16 406 POWER SUPPLY CORD 83 8 3/4 222 WB -1, WB -2 ELECTRICAL SPECIFICATIONS: t MODELS WB-1,WB-2 WAFFLE BAKER DIMENSIONS: INCH (MM) i 1811/32 466 MODEL VOLTS WATTS AMPS PHASE POWER SUPPLY CORD WB -I 120 900 7.5 SINGLE NEMA 5 -ISP WB- I 208 676 3.3 SINGLE NEMA 6 -ISP WB -I 240 900 3.8 SINGLE NEMA 6- 15P WB -2 120 1800 15.0 SINGLE NEMA 5-I5P WB -2 208 1352 6.5 SINGLE NEMA 6-I5P WB -2 240 I800 7.5 SINGLE NEMA 6-I5P NOTE: Specifications are subject to change without notice. Wells Bloomfield, LLC 2 Erik Circle, P.O. Box 280, U.S.A.: (775) 689-5700 • Canada: (877) 507-1700 • Export (775) 689-5700 • www.wellsbloomfield.com © 2007 Wells Bloomfield • 12/07 • No. 37093 Verdi, Nevada 89439 U.S.A. Main Fax (775) 689-5972 (905) 507-1700 • Fax (905) 507-1777 Fax (775) 689-5975 Printed in the U.S.A. J.H. Carr : Coordinated Furniture Solutions for Restaurants, Hospitality, Healthcare and Food Service 1 Tables Page 1 of 4 Tables tord3 sdgghq sd(3458 vtl I (shut) Ink edify ship dj 41 z rrq#thut) horn - edthv 6 3 3 3 tihu ivl dv3- tCi-rri 1dedn#/cropc df 4<33 vhulavl the era grz gf kleda ro p c http: //www. j hcarr. com/products/tab le s/all/ 4;33thulivihqg#d 4 ; 3 3di- 1 Sto bee( 11/21/2012 J.H. Carr : Coordinated Furniture Solutions for Restaurants, Hospitality, Healthcare and Food Service 1 Tables vhud x(345(537; v . -(345(5757 Page 3 of 4 $to: vrny support company contact tools employee log -in find a rep finishes who we are get in touch careers foldcraft.com © 2012 Waymar Companies, All Rights Reserved Terms and Disclaimers 1 Privacy Policy http://www.jhcarr.corn/products/tables/a11/ C( search e.g. siena b-006 go 'oin us 11/21/2012 FireFighter 1 Commercial Waste Receptacles and Trash cans Page 1 of 2 (Search._ A Search I • Home • Outdoor» • Indoor» • Smoking Management» • Restroom Fixtures • About T -Cans • Request Quote • RSS Feed FireFighter Like, 0 IeSt�L l 0 Fiberglass Receptacles Share Fire -Safe, Self -Extinguishing • Conceal unsightly trash and control odors • Self-closing push door cuts off oxygen supply and extinguishes fires • Standard model features a single door • 15 — 40 -gallon capacities • Complies with OSHA standards Description Model # Liners Small Round E Recpetacle Medium Round Receptacle Large F Round Receptacle G Small Square Receptacle Large Square Receptacle H Small Square Tray o FG 1639DRRB RB o FG I 639DRPL PL/GL o FG1837DRRB (n/s) RB o FG1837DR (n/s) PL/GL o FG2439DRRBt RB o FG2439DRPLt PL/GL o FG2038SQDRRB RB (n/s) o FG2038SQDRPL PL/GL (n/s) o FG2438SQDRRBt RB o FG2438SQDRPLt PL/GL FG2037SQTRDRRB RB Gallon Disposal Capacity Dimensions Opening Weight NL PL GL Dimensions 22 15 15 28 20 20 57 36 32 42 29 29 57 40 40 16"dia.x 11"Wx5" 21# 37" H H 24# 18" dia. x 22" W x 30# 37" H 6.5" H 37# 24" Dia. x 13"W x 44# 39" H 6.5" H 53# 20" Sq. x 15" W x 7" 37" H H 24"Sq.x 15"Wx7" 38" H H 56# 50# 56# 50# 42 29 29 20" Sq. x 15" W x 7" 36"H H 50# • [Search_.. • Outdoor Trnsh Can ___ Jr Search Indoor Smobing Palos Call For Assistance 1.866:848-0950 f \ , Ask? us about Replacement -• Parts & Custom a K Laser Engraving http://t-cans.com/indoor/firefighter/ 11/21/2012 FireFighter 1 Commercial Waste Receptacles and Trash cans Page 2 of 2 Top PL/GL FG2037SQTRDRPL Receptacle 56# Large FG2438SQTRDRRBt RB 50# Square Tray (mss) 57 40 40 24" Sq. x 15" W x 7" Top * 38" H H Receptacle FG2438SQTRDRPLI PL/GL 56# (n/s) (n/s) — not shown t Models cannot ship UPS Liner Codes: RB — Poly Bag Retainer $ Available in Dura -Tone and Endura -Crete finishes only. Bands *Indicates FM Approved Fire Save / Self -Extinguishing PL — Germ -Fighter® Products GL — Galvanized Steel Liner Share and Enjoy t•can s.com Sales Office: 10700 Frankstown Rd. Suite 105 Pittsburgh, PA 15235 Phone: 1-866-848-0950 rigmc cm ums rama5Hmn Copyright T -Cans. All Rights Reserved. http://t-cans.com/indoor/firefighter/ 11/21/2012 """rawagair TRUE FOOD SERVICE ® EQUIPMENT, INC. St. Charles Industrial Center • P.O. Box 970 • O'Fallon, Missouri 63366 (636)240-2400 • FAX (636)272-2408 • (800)325-6152 • www.truemfg.com Parts Dept. (800)424 -TRUE • Parts Dept. FAX# (636)272-9471 Model: TUC -27F -LP Undercounter: Low Profile Solid Door Freezer Project Name: Location: Item #: Qty: Model #: AIA # 515 # ADA & Low Profile Comparison Standard 36" height (915 mm) ADA 34" height (864 mm) Low Profile 317/8' height (810 mm) ROUGH -IN DATA Dual swivel castor for "LP" models. 0 True's undercounters are designed with enduring quality and value that protects your long term investment. Our commitment to using the highest quality materials and oversized refrigeration insures exceptional food preservation. / "Low Profile" models are designed to slide easily under custom built countertops. 0 11/2° (39 mm) diameter dual swivel castors. 317/8" (810 mm) work surface height. Oversized, factory balanced, refrigeration system holds -10°F (-23.3°C). Ideal for frozen food and ice cream. 0 Exterior - 300 series stainless steel top, stainless front and sides with matching aluminum back. 0 Interior - attractive, NSF approved, white aluminum liner with 300 series stainless steel floor. 0 Self closing doors. Positive seal, torsion type closure system. 0 Entire cabinet and solid door are foamed -in-place using high density, CFC free, polyurethane insulation. Model: TUC -27F -LP Undercounter: kLow Profile Solid Door Freezer STANDARD FEATURES DESIGN o True's commitment to using the highest quality materials and oversized refrigeration systems provides the user with colder product temperatures, lower utility costs, exceptional food safety and the best value in today's food service marketplace. u "Low Profile" models are designed to slide easily under custom built countertops. REFRIGERATION SYSTEM o Factory engineered, self-contained, capillary tube system using environmentally friendly (CFC free) R404A refrigerant. Y Oversized, factory balanced refrigeration system with guided airflow to provide uniform product temperatures. O Extra large evaporator coil balanced with higher horsepower compressor and large condenser; maintains -10°F (-23.3°C). Ideal for frozen food and ice cream. Y Sealed, cast iron, self-lubricating evaporator fan motor and larger fan blades give True undercounter units a more efficient low velocity, high volume airflow design. This unique design insures colder standard temperature and faster recovery in high use situations. u Condensing unit located in back; slides out for easy maintenance. • Defrost system time -initiated, time - terminated. PLAN VIEW 1 CABINET CONSTRUCTION G Exterior - 300 series stainless steel top,front and sides with matching aluminum back. G Interior - attractive, NSF approved, white aluminum liner. 300 series stainless floor with coved corners. G Insulation - entire cabinet structure is foamed -in-place using high density, CFC free, polyurethane insulation. o 11/2" (39 mm) diameter dual swivel castors permit easy placement. 317/8" (810 mm) work surface height. DOOR o Stainless steel exterior with white aluminum liner to match cabinet interior. G Positive seal, self-closing door with 90° stay open feature. Door swings within cabinet dimensions. O Door fitted with 12" (305 mm) long recessed handle that is foamed -in-place with a sheet metal interlock to insure permanent attachment. G Magnetic door gasket of one piece construction, removable without tools for ease of cleaning. SHELVING o Two (2) adjustable, heavy duty PVC coated wire shelves 231/4"L x 16"D (591 mm x 407 mm). Four (4) chrome plated shelf clips included per shelf. O Shelf support pilasters made of same material as cabinet interior; shelves are adjustable on 1/2" (13 mm) increments. 5529/32° (1421 mm) MODEL FEATURES G Evaporator is epoxy coated to eliminate the potential of corrosion. G NSF -7 compliant for open food product. ELECTRICAL O Unit completely pre -wired at factory and ready for final connection to a 115/60/1 phase - 15 amp dedicated outlet. Cord and plug set included. 115/60/1 NEMA -5-15R OPTIONAL FEATURES/ACCESSORIES Upcharge and lead times may apply. 0 230 - 240V / 50 Hz. 0 Bask overshelf. 0 Single utility shelf. 0 Double utility shelf. 0 Additional shelves. 0 30" (762 mm) deep, 1/2" (13 mm) thick, white polyethylene cutting board. Requires "L" brackets. 0 30" (762 mm) deep, 1/2" (13 mm) thick, composite cutting board. Requires "L" brackets. 0 Heavy duty 16 gauge tops. 0 Standard height unit with 5" (127 mm) diameter castors. 36" (915 mm) work surface height. 0 ADA compliant unit with 34" (364 mm) work surface height. 0 Remote cabinets (condensing unit supplied by others; system comes standard with 404A expansion valve and requires R404A refrigerant). Consult factory technical service department for BTU information. 9 I� 2427/32" l 4 301/16" D 27/16 (632 mm) (764 mm) �J (701 mm) 293/4 ° (756 mm) 71/16" (180 mm) 103/32" ELEVATION (257 mm) WARRANTY One year warranty on all parts & labor and an additional 4 year warranty on compressor. (U.S.A. only) 317/8° (810 mm) (54 mm) L METRIC DIMENSIONS ROUNDED UP TO THE. NEAREST WHOLE MILLIMETER SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE (26 mm) } L11/2° RIGHT VIEW (165/0mm) (39 mm) igra Model Elevation Right Plan 3D TUC -27F -LP TFQY101E TFQY101S TFQYO1P TFQY1013 40 EE (i:®®®S IED73M0CCI E ISIND017011EEfnl4 St. Charles Industrial Center ° P.O. Box 970 0 O'Fallon, Missouri 63366 ° (636)240-2400 ° FAX (636)272-2408 0 (800)325-6152 0 www.truemfg.com modello GEMINI con 1 cappuccinatore e autosteamer gemini Doppie tramoggie di caffe collegate a macinadosatori micrometrici indipendenti, con gruppi di erogazione meccanici. Sei opzioni di caffe programmabili per gruppo, incluse tre opzioni aggiunta latte tramite cappuccinatore incorporato. Due lance vapore, una con controllo automatico della temperatura (Autosteamer), ed una manuale. Prelievo acqua calda tramite tastiera. Accesso per caffe decaffeinato e aromatizzato. Cassetto scarico fondi (disponibile I'opzione di scarico diretto fondi). Twin coffee hoppers linked to independent micrometric grinders and mechanical brewing groups. Six programmable coffee options per group, including three milk added options by means of built-in cappuccinatore. Two steam wands, one with Autosteamer temperature control, and one with manual tap control. Touchpad operated hot water outlet. Decaf and flavoured coffee access point. Grounds discharge to drawer (chute option available). /r r Doble contenedor de cafe en granos unido al moledor micrometro independiente y grupos mecanicos de suministro. Seises opciones de cafe programables para cada grupo, incluidas otras tres opciones para la leche a traves del capuchinador incorporado. Dos lanzas de vapor, una con control automatico de temperatura (Autosteamer) y otra manual. Llenado de agua en caldera mediante botonera. Puntos de suministro para descafeinado y cafes aromatizados. Descarga de posos de cafe en un cajOn (disponible la opciOn de descarga directa de los posos). Double tremie reliee a des moulins a cafe micrometriques independants et groupes cafe macaniques. Six options de cafe programmables par groupe, y comps trois options lait pour le dispositif cappuccino incorpore. Deux lances vapeur, une avec Autosteamer pour le control de la temperature et une pour le control manuel. Prelevement de ('eau chaude par clavier. Points de distribution pour decafeine et cafes aromatises. Evacuation du marc dans un tiroir (11 existe, en option, ('evacuation directe du marc). Doppelter Kaffeetrichter mit Anschluss an unabhangige mikrometrische Kaffeemuhlen sowie mechanische Abgabegruppen. Sechs programmierbare Kaffeeoptionen ie Gruppe. inklusive drei weitere Milchoptionen durch eingebauten Milchaufschaumer. Zwei Dampfsatzeeine mit Kontrol der Temperatur (Autosteamer), and eine handgemachte. Wasseresanzapfung durch eine Tastatur. Abgabestellen fur entkoffeinierte and aromatisierte Kaffees. KaffeesatzausstoB im Fach (Option direkter KaffeesatzausstoB erhaltlich). ■ mini gemini Macchina da caffe superautomatica ad un gruppo con una tramoggia di caffe collegata al macinadosatore micrometrico. Sei opzioni di caffe programmabili, incluse tre opzioni aggiunta latte tramite cappuccinatore incorporato. Una lancia vapore manuale ed un prelievo acqua calda tramite tastiera. (Autosteamer optional). Accesso per caffe decaffeinato ed aromatizzato, cassetto scarico fondi (disponibile I'opzione di scarico diretto fondi). Fully automatic coffee machine with one mechanical brewing group and one coffee hopper linked to micrometric grinder. Six programmable coffee options, including three milk added options by means of built- in cappuccinatore. One manual steam wand and one touchpad operated hot water outlet. (Autosteamer is optional). Decaf and flavoured coffee access point. Grounds discharge to drawer (chute option available). J.H. Carr : Coordinated Furniture Solutions for Restaurants, Hospitality, Healthcare and F... Page 1 of 2 Ifirsvfb #7rcig��•�i ethv sdgghg sd(3458 ship dj xdto surgxfwz j dathuI Uivrxuthv vhc hgj Y. y7:I I c shun hin 4 z rrg#thula hvlrn ehhfk exvfkhtt#?arfr. 6333 vhutn4d-kk: rdr. smigr 4 391 z rrg*hu}a hvhn rdr exvfkhi. earfr 4< 3 3 vhu i dv}: 4; 3 3 vhuhv#hgg4dik: http://www.jhcarr.com/products/tables/a11/ a Top: p ht¢ic shin hvbn ehhfk scaigr 4 ; 3 3 h 4 d\k. 11/21/2012 J.H. Carr : Coordinated Furniture Solutions for Restaurants, Hospitality, Healthcare and F... Page 2 of 2 � T r (imn uzledatrap c era grz glteleth ra p c dffety rir vhud \e(34f(537; vhud ie034ft(5757 support company contact tools employee log -in find a rep finishes who we are get in touch careers foldcraft.com © 2012 Waymar Companies, All Rights Reserved • Terms and Disclaimers 1 Privacy Policy http://www.jhcarr.com/products/tables/all/ 11/21/2012 Rheem GT-199DVP Direct Vent Liquid Propane Heavy Duty Tankless Water Heater - A... Page 1 of 3 Join Prime Your Amazon.com Today's Deals Gift Cards Help Shop by Search Tools & Home Improvement Department gt 199 rheem Go Hello. Sign In Join 0 Wish Your Account Prime Cart List Home Improvement Best Sellers Brands lighting & Ceiling Fans Kitchen & Bath Fixtures Building Supplies Power & Hand Tools Hardware Safety & Security Deals & Bargains Click for larger Image and other views 0 Share your own related Imam Rheem GT-199DVP Direct Vent Liquid Propane Heavy Duty Tankless Water Heater Logy from ;s69.99 by Sheena De the flrst to review this Item 1 (0) Have one to sell? Available from these sellers. new from ;569.99 'p, Top Deals of the Season Get up to 50% off with Bladk Fddav deals In Tools & Home Improvement. Save a bundle while fulfilling your wishlist. Shoo now. Sham Product Features • 7.4 GPM at a 45 degrees F temperature rise (up to 8.5 GPM at 35 degrees F) • Electronic ignition increases efficiency (no standing pilot light) • Exclusive! Guardian OFW overheat film wrap • A remote control thermostat is included with all models with 100 degrees F - 180 degrees F setpoint range (factory set at 120 degrees F) • Digital display on thermostat shows temperature setting and maintenance/error codes Customers Viewing This Page May Be Interested in These Sponsored Links (what's this?) Tankless Water Heaters - Takagi and Eco 4 Tankless Heaters On Sale Now. Call Today! www.advancedproductsonline.com/ Tankless Water Heaters - Starting at $2500 Installed! Contact Us Today - (206) 778-9854 www.blacklionhvac.com/ Tankless Water Heaters - In Stock, Low Prices, Free Shipping Paloma-Takagi-Stiebel Eltron & More designerplumbing.com/TanklessHeater See a problem with these advertisements? Jot us know Product Specifications Part Number Item Package Quantity GT-199DVP Product Description Includes Direct Vent Liquid Propane Heavy Duty Tankless Water Heater - GT-199DVP Product Details Shipping Weight: 55 pounds ASIN: BOO1BKW7G8 Average Customer Review: )3e the first to review this Item Amazon Best Sellers Rank: #67,231 in Home Improvement (See Too 100 in Home Improvement) Did we miss any relevant features for this product? Tell us what we missed. Would you like to update product Info, give feedback on Imaaes, or tell us about a lower price? Customers Who Viewed This Item Also Viewed http://www.amazon.com/Rheem-GT-199DVP-Direct-Propane-Tankless/dpB001 BKW7... 11/22/2012 Rheem GT-199DVP Direct Vent Liquid Propane Heavy Duty Tankless Water Heater - A... Page 2 of 3 Richmond Rmtg-66dvp Indoor Direct Vent Tankless Water Heater Lp (1) Rheem RTG-84DVP Low Nox Direct Vent Tankless Water Heater Liquid Propane Energy Star 8.4 GPM $877.54 (1) Product Ads from External Websites (what's this?) tetat4tau Takagi TH2DVNG White Energy Star Direct Vent Tankless Water Heat... $1,256.41 + $40.00 Est. shipping Bulld.com 1 �I� Takagi TH2DVLP White Energy Star Direct Vent Tankless Water Heat... $1,256.41 + $40.00 Est. shipping FaucetDlrect See a problem with these advertisements? Let us know Customer Reviews There are no customer reviews yet. 5 star 4 star 3 star 2 star 1 star to . I BI Eccotemp 40HI-LP Indoor Propene Tankless Water Heater, 135,000 British Thermal Unit (6) $437.58 Rheem RTG-64DVP Indoor Tankless Water Heater for 1-2 Bathroom Ho... $649.99 + Free Shipping Westaide Wholesale Share your thoughts with other customers Write a customer review Customer Questions & Answers Listmania! Bosch 660EFLP Therm 660 EF Liquid Propane Therm Indoor Tankless Water Heater $399.99 Rheem RTG-84XP Outdoor Tankless Water Heater for 2-3 Bathroom Ho... (1) $784.99 + Free Shipping Westside Wholesale Rheem RTG-64DVLP Prestige Low NOx Indoor Direct Vent Condensing Tanldess Propane Water Heater $611.97 ®1 Eccotemp FVI-12-LP High Capacity Propane Tankless Water Heater (27) $269.00 MN: Rheem RTG-95XP Outdoor Tankless Water Heater for 2-3 Bathroom Ho... $964.99 + Free Shipping Westalde Wholesale Sponsored Content Advertise here Advertisement http://www.amazon.com/Rheem-GT-199DVP-Direct-Propane-Tankless/dp/B001 BKW7... 11/22/2012 Rheem GT-199DVP Direct Vent Liquid Propane Heavy Duty Tankless Water Heater - A... Page 3 of 3 So You'd Like to... eGift This Item iwn.t..thio) Instant Delivery: E-mail a gift card suggesting this Item Flexible Gifting Choices: They can choose 00 this, or pick from millions of other items. cat stared _ Thought Sou ll+ught like this.. Look for Similar Items by Category Tools & Home Improvement > Roush Plumbing > Water Heaters & Part*, Feedback ► If you need help or have a question for Customer Service, contact ud. ► Would you like to update product Info, give feedback on Images or tell us about a lower Price? ► Is there any other feedback you would like to provide? Click here Your Recent History (what's this?) Loading Get to Know Us Make Money with Us Let Us Help You Careers Sell on Amazon Your Account Investor Relations Become an Affiliate Shipping Rates & Policies Press Releases Advertise Your Products Amazon Prime Amazon and Our Planet Independently Publish with Us Retums Are Easy Amazon in the Community > See all Manage Your Kindle Help amazon-com Canada China France Germany Italy Japan Spain United Kingdom AbeBooks AmazonLocal AmazonSupply AmazonWebSeMces AmazonWireless Askviile Audible BeautyBar.com Book Depository Rare Books Great Loral Deals Business, Industrial Scalable Cellphones & Community Download Prestige Beauty Books With Free & Textbooks In Your City & Scientific Supplies Cloud Services Wireless Plans Answers Audio Books Delivered Delivery Worldwide CreateSpace Dlapero.com DPRevlew Fabric IMDb Junglee.com MYHABIT Shopbop Soap.com India Publishing Everything Digaal Sewing, Quilting Movies, TV Shop Online Private Fashion Designer Health, Beauty & Made Easy But The Baby Photography & Knitting & Celebrities in India Designer Sales Fashion Brands Home Essentials Wag.com Warehouse Deals Woot Yoyo.com Zappos Vine.com Casa.com Everything Open -Box Never Gonna A Happy Place Shoes & Everything Kitchen, Storage For Your Pet Discounts Give You Up To Shop For Toys Clothing to Live Life Green & Everything Home Conditions of Use Privacy Notice Interest -Based Ads ®1996-2012, Amazon.com, Inc. or its affiliates http://www. amazon.com/Rheem-GT-199DVP-Direct-Propane-Tankless/dpB001 BKW7... 11/22/2012 11-01-2013 City of Tukwila Jinl Haggerton, Mayor Department of Community Development Jack Pace, Director ZACH MILLER 5700 100 ST SW, SUITE 330-152 LAKEWOOD, WA 98499 RE: Permit No. D13-113 BLACK BEAR YOGURT 17250 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/14/2013. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/14/2013, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, E`ki° Bill Rambo Permit Technician File: Permit File No. D13-113 6300 Southcenter Boulevard. Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Environmental Health Services Division 401 Fifth Avenue, Suite 1100 Seattle, WA 98104-1818 206-263-9566 Fax 206-296-0189 TTY Relay: 711 www.kingcounty.gov/health January 31, 2013 Zach Miller BBFYE, LLC 5700 100th St SW, #330-152 Lakewood, WA 98499 253-212-7882 Public Health 61 Seattle & King County Also transmitted via Electronic Mail RE: Plans and Specifications for the new food service establishment: Black Bear Frozen Yogurt & Espresso 17200 Southcenter Parkway, #148, Tukwila, WA 98188 SR1232766 P/E = 6722 Dear Mr. Miller, RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER The plans and specifications for the above new project have been reviewed and, in accordance with the provisions of Title 5, the Code of the King County Board of Health Rules and Regulations 05-06 (The Food Code) are hereby APPROVED. Your establishment has been assigned the following plan review service number SR1232766. Please use this SR# in all future contact with us. As required in The Food Code, upon completion of the construction and before opening for business, the food service establishment operator/owner shall: 1. Complete the enclosed application for the annual operations permit if you don't have a current permit. Include a copy of this letter when applying for the annual permit. Please call me prior to paying for your permit to verify the correct fee. Be advised that the penalty for commencing operation of a food service establishment without the required permit is 50% of the applicable permit fee. 2. Obtain a preoperational inspection approval. Contact Michael Bratcher (206-296- 9741) at least one week in advance to schedule a preoperational inspection. Be sure all other inspections (plumbing, building, etc.) are done before you call the Health Department for an inspection. X13-113 OAVIG4)0Ak`�"d� Your application for a food service establishment permit from Public Health Seattle & King County may be approved during this inspection. However, it is the responsibility of the food service establishment operator/owner to obtain all necessary permits and approvals from other agencies. Operating the establishment without these required permits or approvals may subject the operator/owner to legal action by the appropriate agencies. If the establishment is opened without the Health Department preoperational inspection, it may be subject to closure. Failed preoperational inspections will require a $402.00 fee (+$201.00/hr after 2 hours) for a repeat inspection. Please be aware that additional hourly fees will be charged if the total plan review and preoperational inspection goes beyond the base plan fee for this project. An invoice may be sent to you after the preoperational inspection. Your permit to operate will be sent to you after this fee has been paid. If you have any questions, please don't hesitate to contact me. Thank you for your compliance in this matter and I look forward to seeing you soon. Sincerely, ichael Bratcher Plan Reviewer Senior Health & Environmental Investigator 206-296-9741 www.michael.bratcherkingcountv.gov cc: Berhanu Alemayehu MB pE co PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-113 DATE: 04-10-13 PROJECT NAME: BLACK BEAR FROZEN YOGURT SITE ADDRESS: 17250 SOUTHCENTER PY, SUITE 148 X Original Plan Submittal Response to Correction Letter # Revision # After Permit Issued Response to Incomplete Letter # D PARTMENTS: ( Building ivision Publico s 4w Awc- yob -(3 A? Fire Prevention r Planning Division Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 04-11-13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: n DUE DATE: 05-09-13 Not Approved (attach comments) n Permit 'Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc • 2-28-02 PLAN REVIEW CHECKLIST - (Nonstructural) Permit App. p /1 /(T By: IBC Edition 699 & State Amend. Date: V—/2--/,3 Project title:/c K �QQ J�,r�ro451A I +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Classify the building or portion thereof in accordance with Chapter 3 (131 --Determine the type of construction of the building in accordance with Chapter 6. Determine if the location of building on the site and clearances to property lines and other buildings on the site plan are in accordance with code provisions. Review for conformity with General building height and area limitations in accordance with Chapter 5. (f�� Review for conformity with special detailed requirements based on use and Occupancy. Review for conformity with Type of Construction requirements of Chapter 6. Review for conformity with Fire and Smoke protection features of Chapter 7. P Review for conformity with requirements of interior finishes of Chapter 8. —Review for conformity with requirements for fire protection systems of Chapter 9. Review for conformity with requirements for means of egress requirements of Chapter 10 V)/Review for conformity with requirements of accessibility in accordance with Chapter 11, and ICC A117.1 3 Review for conformity with Washington State Energy Code. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Ni In circle = topic has been reviewed for the application. X In circle = topic is not relevant to proposed scope of work. Contractors or Tradespeopl renter Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name FINAL CUT CONSTRUCTION UBI No. 602263763 Phone 2532227723 Status Active Address 9927 98Th St Sw License No. FINALCC977B1 Suite/Apt. License Type Construction Contractor City Tacoma Effective Date 1/21/2003 State WA Expiration Date 3/9/2014 Zip 98498 Suspend Date County Pierce Specialty 1 General Business Type Individual Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date RAYGOR, THOMAS ALAN Owner 01/21/2003 Amount RAYGOR, SHERRIE ANNE Spouse 03/12/2010 C11SF3336 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 CBIC SF3336 12/23/2003 Until Cancelled $12,000.00 03/09/2010 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 CBIC C11SF3336 03/08/2010 03/08/2014 $1,000,000.0001/18/2013 3 CBIC INSSF3336 12/23/2008 12/23/2009 01/21/2009 $1,000,000.0012/05/2008 2 CBIC INSSF3336 12/23/2003 12/23/2007 $1,000,000.0012/12/2006 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period httns://fortress.wa.aov/lni/bbin/Print.asnx 05/21/2013 GENERAL NOTES 1 ARCHITECT OF RECORD: DAVID SOVA - HE HAS OR *IILL REVIEW AND COORDINATE ALL SUBMITTALS AND DOCUMENTS PREPARED BY OTHERS INCLUDING ANY DEFERRED SUBMITTALS FOR COMPATIBILITY WITH THE DESIGN ACCORDING TO SECTION 107.3.4.1, 2009 IBC. 2 ALL CONSTRUCTION AND MATERIALS SHALL BE AS SPECIFIED AND AS REQUIRED BY THE CURRENT EDITION OF THE I.B.C. I.P.C., I.M.C., N.E.C., I.F.C.. LOCAL CODE ADMENDMENTS AND AUTHORITIES. REFERENCES TO THE IBC IN THESE DOCUMENTS SHALL MEAN THE 2009 INTERNATIONAL BUILDING CODE, WITH APPLICABLE STATE & LOCAL AMENDMENTS. 3 ARCHITECT IS NOT RESPONSIBLE FOR THE ACCURACY OF THE INFORMATION CONTAINED IN DOCUMENTS AND/OR SUBMITTALS SUPPLIED BY OTHERS. 4 EACH CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE STARTING WORK. SHOULD A DISCRE- PANCY APPEAR IN THE SPECIFICATIONS OR DRAWINGS, OR IN THE WORK DONE BY OTHERS FROM THE CONTRACT DOC- UMENTS THAT AFFECT ANY WORK, NOTIFY THE ARCHITECT AT ONCE FOR INSTRUCTIONS ON HOW TO PROCEED. IF THE CONTRACTOR PROCEEDS WITH THEWORK AFFECTED WITHOUT INSTRUCTIONS FROM THE ARCHITECT, THE CONTRACTOR SHALL MAKE GOOD ANY RESULTING DAMAGE OR DEFECT TO THE SATISFACTION OF THE ARCHITECT. SHOULD A CON- FLICT OCCUR IN OR BETWEEN DRAWINGS AND SPECIFICATIONS. OR WHERE DETAIL REFERENCES ON CONTRACT DRAWINGS HAVE BEEN OMITTED. THE CONTRACTOR IS DEEMED TO HAVE ESTIMATED THE MOST EXPENSIVE MATERIALS AND CON- STRUCTION METHOD INVOLVED, UNLESS A WRITTEN DECISION FROM THE ARCHITECT HAS BEEN OBTAINED WHICH DES- CRIBES AN ALTERNATE METHOD AND/OR MATERIALS. 5 EACH CONTRACTOR SHALL CONFINE HIS OPERATIONS ON THE SITE TO AREAS PERMITTED BY THE OWNER. THE WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE LAWS, LOCAL ORDINANCES, PERMITS AND THE CONTRACT DOCU- MENTS. THE JOB SITE SHALL BE MAINTAINED IN A CLE ORDERLY CONDITION FREE OF DEBRIS AND LITTER. AND SHALL NOT BE UNREASONABLY ENCUMBERED WITH ANY MATERIALS OR EQUIPMENT. EACH CONTRACTOR DURING AND IMMEDIATELY UPON COMPLETION OF EACH PHASE OF HIS WORK SHALL REMOVE ALL TRASH AND DEBRIS AS A RESULT OF HIS OPERATION. 6 ALL MATERIALS STORED ON THE SITE SHALL BE PROPERLY STACKED AND PROTECTED TO PREVENT DAMAGE AND DE- TERIORATION UNTIL USE. FAILURE TO PROTECT MATERIALS MAY BE CAUSE FOR REJECTION OF WORK. 7 EACH CONTRACTOR SHALL DO ALL CUTTING, FITTING OR PATCHING OF HIS WORK THAT MAY BE REQUIRED TO MAKE ITS SEVERAL PARTS FIT TOGETHER PROPERLY AND SHALL NOT ENDANGER ANY OTHER WORK BY CUTTING. EXCAVATING OR OTHERWISE ALTERING THE TOT WORK OR ANY PART OF IT. ALL PATCHING. REPAIRING AND REPLACING OF MAT- ERIALS THAT THEYD SURFACES REPLACED, UPON CUT OR GED IN COMPLETION, EXECUTION MATCH SURROUND NG SIMILAR ORK, SHALL BE SEURFACITH SPLICABLE MATERIALS SO 8 NO PORTION OF THE WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL BE COMMENCED UNTIL THE SUBMISSION HAS BEEN REVIEWED BY THE ARCHITECT. ALL SUCH PORTIONS OF THE WORK SHALL BE IN ACCORDANCE WITH APPROVED SHOP DRAWINGS AND SAMPLES. 9 DIMENSIONS: A. ALL DIMENSIONS SHALL HAVE PREFERENCE OVER SCALE. B. CEILING HEIGHT DIMENSIONS ARE FROM FINISH FLOOR SLAB TO FINISH FACE OF CEILING. 10 PROVIDE BLOCKING FOR WALL MOUNTED FIXTURES, ACCESSORIES AND EQUIPMENT 11 ALL OPEN JOINTS AND PENETRATIONS IN THE BUILDING ENVELOPE SHALL BE SEALED OR WEATHER STRIPPED 13 MAXIMUM 1/2" RISE BETWEEN TOP OF THRESHOLD AND ADJACENT FINISHED FLOOR. CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2. 14 ALL DOORS SHALL BE PROVIDED WITH LEVER HARDWARE OPENABLE WITH A SINGLE EFFORT. 15 ALL LEGAL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT. EXIT SIGNS SHALL BPDEATALL EXITS REQUIRED ID BY CODE. ALL DOOR SWINGS SERVING AN OCCU- PANT LOF 50 OR GREATERERROA IN THE DIRECTION p EXIT. 16 ADJUST DOOR CLOSERS AT EXTERIOR DOORS TO 8.5 LBS. OF PRESSURE. AT INTERIOR DOORS TO 5 LBS. OF PRESSURE, AND FIRE RATED DOORS TO 15 LBS. OF PRESSURE. 17 PROVIDE SIGN OVER MAIN ENTRY DOOR WHICH READS 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS' WITH LETTERS NOT LESS THAN 1" HIGH ON CONTRASTING BACKGROUND. 18 DOOR OPENING FORCE: 30 LBS. MAX. APPLIED TO LATCH SIDE. 19 ALL NEW GYP BOARD WALLS SHALL RECEIVE A LEVEL 4 SURFACE AND PAINT FINISH. U.N.O. 20 ALL INTERIOR MATERIALS AND FINISHES SHALL BE A MINIMUM CLASS III FLAME SPREAD 21 PROVIDE FIRE EXTINGUISHERS PER CODE (EVERY 75'-0") AND FIRE MARSHALL'S INSTRUCTIONS 22 ALL PIPING SHALL BE IN WALLS OR FURRED CEILING SPACES UNLESS NOTED OTHERWISE. 23 VERIFY ALL THERMOSTAT AND ELECTRICAL PANEL LOCATIONS WITH ARCHITECT OR TENANT PRIOR TO FINAL INSTALLATION 24 ALL LIGHT FIXTURES & BALLASTS SHALL BE ENERGY SAVING TYPE. 25 HEN OUTLETS AND JUNCTION BOXES ARE INDICATED ON OPPOSITE SIDES OF A WALL. THEY SHALL BE SEPARATED BY MINIMUM OF ONE STUD. 0 0 HEALTH DEPARTMENT CRITERIA WATER & SEWER: EMPLOYEES: EQUIPMENT: INTERIOR WALL SURFACES: LIGHTING: FOOD: HAND WASHING: SINKS AND LAVS: HOOD EXHAUST SYSTEM: FAUCETS: FLOOR SINKS: WATER HEATER: STORE HOURS: MUNICIPAL WATER AND SEWER SERVICES 4 ALL EQUIPMENT IS NSF APPROVED SMOOTH WALLS WASHABLE PAINT, MINIMUM 4' FRP WAINSCOT (6' FRP WAINSCOT SPECIFIED) IN ALL FOOD PREP AREAS MINIMUM 2' FRP BACK SPLASH ABOVE ALL PREP COUNTERS AND SINKS MINIMUM OF 20 FOOT CANDLES (215 LUX) OF LIGHT IN ALL FOOD PREPARATION AREAS AND 10 FOOT CANDLES (100 LUX) IN STORAGE AREAS. SHATTER SHIELDS SHALL BE PROVIDED IN FOOD, WORK AND STORAGE AREAS. 100% PRE-PACKAGED AND 100% SINGLE SERVICE A WALL MOUNTED SINGLE SERVICE TOWEL AND SOAP DISPENSER SHALL BE PROVIDED AT EACH HAND SINK ALL SINKS AND LAVATORIES SHALL BE SUPPLIED WITH HOT (MIN. 120 DEGREES F) AND COLD RUNNING WATER UNDER PRESSURE WITH A 2" AIR GAP BETWEEN DISCHARGE AND FLOOR SINK. ALL SINKS AND LAVATORIES SHALL COMPLY WITH EHP-883 NOT APPLICABLE (THERE IS NO HOOD IN THIS PROJECT) ALL FAUCETS SHALL HAVE A COMBINATION FAUCET MOP SINK SHALL HAVE AB ANTI -SIPHON DEVICE ALL FLOOR SINKS SHALL BE EASILY ACCESSIBLE AND CLEAN ABLE WATER HEATER SHALL BE ON DEMAND COMMERCIAL TYPE AND SHALL PROVIDE 5 GPM @ 140 DEGREES AND 1.5 GPM @ 120 DEGREES WATER TO HAND SINKS STORE HOURS SHALL BE A MAXIMUM OF 12 PER DAY. STORE SHALL BE OPEN FROM 10AM TO 10PM MON-SUNDAY a) 24 HOURS NOTIFICATION TO THE HEALTH DEPARTMENT IS REQUIRED FOR ALL INSPECTIONS PRIOR TO THE STORE OPENING b) PROJECT MUST MEET COUNTY AND STATE HEALTH DEPARTMENT REGULATIONS AND CRITERIA SEATTLE & KING COUNTY INSPECTION REQUIRED ONCOMPLETION OF WORK PRIOR TO OPENING NO CHANGES TO PLAN WILL BE MADE WITHOUT HEALTH DEPARTMENT APPROVAL AGENCY NOTES PROJECT DESCRIPTION: PROJECT ADDRESS: PARCEL #: LEGAL DESCRIPTION: BUILDING CODE: TYPE OF CONSTRUCTION: OCCUPANT TYPE: TENANT FLOOR AREA: MEZZANINE AREA CHANGE OF OCCUPANCY FROM "M" TO "A2" AND TENANT IMPROVEMENTS TO AN EXISTING RETAIL SPACE (SUITE 148) 17200 SOUTHCENTER PKWY TUKWILA, WA 98188-3301__ 788892-0020 SOUTHCENTER SQUARE BSIP 2009 IBC TYPE II WITH AUTOMATIC SPRINKLER SYSTEM A2 RESTAURANT PER SECTION 303.1 1,935 + 591 = 2,526 SF GROSS AREA IBC SECTION 505: THE AGGREGATE AREA OF A MEZZANINE WITHIN A ROOM SHALL NOT EXCEED 1/3rd OF THE FLOOR AREA OF THE ROOM OR SPACE IN WHICH IT IS LOCATED FIRST FLOOR AREA 1935 / 3 = 645 SF MAX AREA (591 ACTUAL PROPOSED) OCCUPANT LOAD PER TABLE 1004.1.1 SEATING SEATING (MEZZANINE) STANDING LINE PREP AREA RESTROOMS TOTAL OCCUPANT LOAD OCCUPANCY SEPARATIONS PER TABLE 508.4 GROUPS SEPARATION RATING A2 / M 1 HOUR PARTITION) 1/15 SF NET 963 SF / 15 = 64 1/15 SF NET 591 SF / 15 = 39 1/5 SF NET 123 SF / 5 = 25 1/200 SF GROSS 348 SF / 200 = 2 1/100 NET 105 SF / 100 = 1 131 FIRE SEPARATION DESIGN UL DESIGN 468 (EXISTING FULL HEIGHT WALLS) MAX EXIT TRAVEL DISTANCE PER TABLE 1016.1 = 200' 2 EXITS REQUIRED PER TABLE 1021.1 (OCCUPANT LOAD BETWEEN 1-500) EXIT SEPARATION PER SECTION 1015.2.1 EXITS MUST BE MORE THAN 1/3 THE MAX DIAGONAL DISTANCE 93'-1" MAX DIAGONAL / 3 = 31'-0" MINIMUM SEPARATION (ACTUAL DISTANCE IS 91'-3") PROJECT TEAM INDEX TO DRAWINGS PROPERTY MANAGEMENT: WIG PROPERTIES LLC 4811 134TH PL SE BELLEVUE, WA 98006 CONTACT: ANJALI WIG EMAIL: anjaliwig@wigproperties.com PHONE: 425.644.6126 FAX: 425.865.8648 TENANT: BLACK BEAR YOGURT & ESPRESSO 5700 100TH STREET SW, SUITE 330-152 LAKEWOOD, WA 98499 CONTACT: ZACH MILLER EMAIL: zachmiller788@gmail.com PHONE: 253.212.7882 SEPARATE PERMIT REQUIRED FOR: MechanIcal ifitlectrical Plumbing Piping City of Tukwila 131.1rG DIVISION ARCHITECT: DSDAA 2249 80TH AVENUE SE MERCER ISLAND, WA 98040 CONTACT: DAVID SOVA AIA EMAIL: david@dsdaa.com PHONE: 206.617.9010 STRUCTURAL ENGINEER COUGHLIN PORTER LUNDEEN 413 PINE STREET SUITE 300 SEATTLE, WA 98101 CONTACT: ERIC DIXON, P.E. EMAIL: ericd@cplinc.com PHONE: 206.343.0460 FAX: 206.343.5691 FOOD SERVICE CONSULTANT: 3D DESIGN SERVICES 2734 GRAND FIR PL SE PORT ORCHARD, WA 98366 CONTACT: CLYDE LANGWORTHY EMAIL: clydelang@gmail.com PHONE: 360.769.3970 MOBILE: 360.550.8055 • REVISIONS No changes shall be made to the scope of rtork without prior approval of Tukwila Building Division. I O T .'!: Revisions will require a new plan submittal d may ins ude additional plan review fees. A0.1 A0.2 A1.0 A1.1 A1.2 A1.3 A1.4 A1.5 A1.6 A1.6.1 A1.7 A2.0 A3.0 A3.1 A3.2 KC.0 KC.1 KC.2 KC.3 KC.4 KC.4.1 KC.9 S1.1 S1.2 S2.1 S2.2 S3.1 COVER SHEET, INDEX, AGENCY NOTES, CODE DIAGRAM, VICINITY MAP REFERENCE PLAN EXISTING FLOOR PLAN / DEMOLITION PLAN PROPOSED FLOOR PLAN FURNITURE PLAN ELECTRICAL PLAN FINISH PLAN REFLECTED CEILING PLAN ENLARGED PLANS (SERVING AREA :..Q H, , T ROOMS) ENLARGED PLAN (TAYLOR LINE) ROOF PLAN INTERIOR ELEVATIONS CASEWORK DETAILS ROSETTO WALL DETAILS STAIR / RAILING DETAILS COVER SHEET EQUIPMENT PLAN PLUMBING PLAN ELECTRICAL PLAN INTERIOR ELEVATIONS INTERIOR ELEVATIONS 3-D VIEWS GENERAL STRUCTURAL NOTES GENRAL STRUCTURAL NOTES FOUNDATION PLAN MEZZANINE FRAMING PLAN DETAILS Hitkik Mitta 0040.1t14 tAtrWttl' PROPOSED BLACK BEAR YOGURT NORTH 4Di, SOUTHCENTER SQUARE NORTH CARTER'S CLOTHING STORE (M) 1 RESTROOM 1 58 SF 000 RESTROOM 2 47 SF 1 •�}}(i-::1 r,........--. 1 1 .- 1 1 1t , i \'\\\ 1~ i11}1 it1 1u•s ss1• tit PREP AREA 348 SF \r\ }__.! tIP 1 1•111 t" t j i}�.. 1 ;� 1 ,1 : - EXIT SEPARATION DISTANCE 91'-3" PLANNING APPROVED. No changes can beto plans without app Planning Approved By: Date: 14-11- k • CODE DIAGRAM / EXIT TRAVEL DISTANCE / OCCUPANCY TYPE SCALE; 1/4" = 1'-0" Immatmol 0 0 0 u -II- Cyqj CUSTOMER SEATING AREA (UNCONCENTRATED TABLES & CHAIRS) FIRST FL 976 SF + MEZZANINE 591 SF = 1,567 SF DIACONAL. DISTANCE 93*- 1" BEAR �"�`' FIREPLACE i SLE COP e.. Permit No.. PI^� r•^"'iew approval is subject to errors and omissions. . of construction documents does not auttloit3 gal any adopted code or ordinance. Recti pt �t L42)proved Field Copy and conditions is acknowledged: By Date: oma: 5/2i City Of 1Ukwlla BUILDING DIVISION PANERA BREAD (A2) DEC i4 201, REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION °5 - RECEIVED APR 11 2013 TUKVvILJ-\ PUBLIC WORKS RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER NORTH 1 DSDAA Plan Finance Deiign Build 2249 80th Avenue SE Mercer Island, WA 98b40 206 . 617 , 9010 11 �lo Note Stamp Date Author Description 7402 REGISTERED AR ITECT VID SOYA sTA AsHINGToN Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Cover sheet Scale: As Noted Drawn by: DS Checked by: Date: 11/30/'12 A0.1 Sheet Number: Job Number. MATERIAL COLOR MANUFACTURER NOTES PT1 LATEX/ENAMEL PAINT BRICK (RED) TBD ACCENT WALL PT2 LATEX/ENAMEL PAINT CARAMEL (YELLOW) TBD ACCENT WALL PT3 LATEX PAINT: FLAT FINISH CHOCOLATE TBD DEFAULT COLOR, BASE BUILDING ELEMENTS & CEILINGS, PT4 LATEX/ENAMEL PAINT PUMKIN TBD ACCENT WALL — SECTIONS OF WAC LIGHTING 120V SINGLE CIRCUIT TRACK LENGTHS VARY (2', 4', 8') ZACHARY TIBBITTS / PLATT ELECTRIC 5520—A 112TH STREET E PUYALLUP, WA 98373 PHONE 253.840.3301 N/A N/A — ST1 CULTURED STONE VENEER SEQUOIA RUSTIC LEDGE ELDORADO STONE W WW.eldorodostone.com FIREPLACE AND ACCENT WALL 64 WATT 384 FL FRP FIBERGLASS REINFORCED PLASTIC TBD MARLITE / DAVE RUPPLE 330.260.7608 BACK OF HOUSE — REFER TO ELEVATIONS O ORS9200 411) L4 PL1 PLASTIC LAMINATE 4794-60 "WINDSWEPT BRONZE" WILSONART 1.800.433.3222 COUNTER TOPS AND EDGES PL2 PLASTIC LAMINATE 6213 "WOOD STRAND" FORMICA 1.800.FORMICA VERTICAL FRONT PANELS PL3 PLASTIC LAMINATE 6306 "WENGE STRAND" FORMICA 1.800.FORMICA TOILET ROOMS METAL EDGE TRIMS TYPICAL 320 INC i.- AC1 101 M1 M1 20 CFM EXHAUST FAN TO OPERATE WHEN ROOM LIGHT IS ON ME MECHANICAL CONTRACTORTD 2 O L1 L1 PROGRESS LIGHTING WESTIN MINI — PENDANT P5108-20EBWB (WHITE FROSTED SHADE/ANTIQUE BRONZE STEM) TRACK MOUNTED CD1 1X4 CLEAR CEDAR PLANK NATURAL, CLEAR SEALER SITE BUILT REFER TO INTERIOR ELEVATIONS O L5 L5 COOPER COMMERCIAL RECESSED 6" CAN LIGHT PD6H126 (26W) A) 6HBB SPECULAR CLEAR REFLECTOR WITH BLACK BAFFLE, TYP B) 1705 REFLECTOR W/TEMPERED GLASS SHIELD AT FOOD PREP ZACHARY TIBBITTS / PLATT ELECTRIC 5520—A 112TH STREET E PUYALLUP, WA 98373 PHONE 253.840.3301 27 SS1 CUSTOM SS FASCIA STAINLESS STEEL DSL SEATTLE W**.dslinc.com DSL TRENT BARBRE KENT, WA 98032 425.264.0383 0X1 X1 SELF ILLUMINATING LED EXIT SIGN MAXIMUM OF 5 WATTS TBD LP1 ARMSTONG LUXE PLANK FLOORING FOUNDRY GRAY A6786-721 ARMSTRONG yyyyyy.ormstrong.com/flooring CUSTOMER SEATING AREA LS1 MARMOLEUM (LINOLEUM) SHEET FOREST GROUND CP -3234 FORBO WW*.forboflooringno.com PREP AREAS AND TOILET ROOMS (6" SELF COVE BASE) RB1 6" VINYL BASE 110 "BROWN" ROPPE CORP USA 1.800.537.9527 TYPICAL HB1 HEADER BEAM TABLE LENGTH VARIESLOSS BLACK TENANT PROVIDED 12X6 GLU—LAM/CUSTOM STEEL LEGS BLACK POWDER COAT NOTES: FINISH SCHEDULE SCALE; N/A 0 o- SYM TYPE DESCRIPTION SOURCE QTY WATTS EA. TOTAL NOTES g T1 T1 WAC LTK-764-BK PAR 30 GIMBLE RING BLACK WITH 12W PAR 30 / 36DEG DIMMABLE FLOOD ZACHARY TIBBITTS / PLATT ELECTRIC 5520—A 112TH STREET E PUYALLUP, WA 98373 PHONE 253.840.3301 21 12 WATTS 252 LED O T2 T2 "KOMAL" BLOWN GLASS PENDANT (RED) QP-59 03 RDDT N,MABRUSHED NICKEL SOCKET SET 503—RD/BN, 12.84 ZACHARY TIBBITTS / PLATT ELECTRIC 55 0-A2NE5 112TH .3301STREET E PUYALLUP, WA 98373 2 50 WATTS 100 INC — SECTIONS OF WAC LIGHTING 120V SINGLE CIRCUIT TRACK LENGTHS VARY (2', 4', 8') ZACHARY TIBBITTS / PLATT ELECTRIC 5520—A 112TH STREET E PUYALLUP, WA 98373 PHONE 253.840.3301 N/A N/A — 2X4 RECESSED FLUORESCENT (2) 32 WATT 48" T8 LAMPS ZACHARY TIBBITTS / PLATT ELECTRIC 5520—A 112TH STREET E PUYALLUP, WA 98373 PHONE 253.840.3301 6 64 WATT 384 FL O ORS9200 411) L4 LIGHTSUP 9200 SERIES PENDANTS (3) DRUM PENDANTS IN A CLUSTER BUC 11" DIA "BURNISH CHINTZ" 25 WATT CFL RS9203 CHO 14" DIA "CHOCOLAT" 40 WATT CFL RS9204 NAT 18" DIA "NATURAL LINEN" 40 WATT CFL RICK LEECHAO / LIGHTING SUPPLY INC. 2729 SECOND AVE SEATTLE WA 98121 206.441.5075 WWWLIGHTINGSUPPLY.NET 4 105 420 CFL AC1 MULE DEER CLUSTER CHANDELIER REQUIRES (8) 40 WATT INCANDESCENT, MEDIUM BASE, LAMPS (320 WATTS) SIZE: DIAMETER 38" TO 40" / HEIGHT 30" REPRODUCTION MULE DEER ANTLER CLUSTER ANTLER LIGHTING WAREHOUSE MANITOBA, CANADA PHONE: 204-898-4554 HTTP://WWW.ANTLERCHANDELIER.ORG 1 320 WATTS 320 INC i.- AC1 101 M1 M1 20 CFM EXHAUST FAN TO OPERATE WHEN ROOM LIGHT IS ON ME MECHANICAL CONTRACTORTD 2 O L1 L1 PROGRESS LIGHTING WESTIN MINI — PENDANT P5108-20EBWB (WHITE FROSTED SHADE/ANTIQUE BRONZE STEM) TRACK MOUNTED PROGRESS LIGHTING 701 MILLENIUM BLVD GREENVILLE, SC 29607 WWW.PROGRESSLIGHTING.COM 30 13 WATT 390 CFL O L5 L5 COOPER COMMERCIAL RECESSED 6" CAN LIGHT PD6H126 (26W) A) 6HBB SPECULAR CLEAR REFLECTOR WITH BLACK BAFFLE, TYP B) 1705 REFLECTOR W/TEMPERED GLASS SHIELD AT FOOD PREP ZACHARY TIBBITTS / PLATT ELECTRIC 5520—A 112TH STREET E PUYALLUP, WA 98373 PHONE 253.840.3301 27 26 WATTS 702 CFL 0X1 X1 SELF ILLUMINATING LED EXIT SIGN MAXIMUM OF 5 WATTS TBD 3 5 WATTS 15 LED NOTES: TOTAL PROPOSED WATTS: 2,583 o) FINISIHED CEILING HEIGHT ® 9'-9" AFF / GROSS FLOOR AREA OF SPACE = 2,024 SF + 591 (MEZZANINE) = 2,615 SF TOTAL b) MAXIMUM LIGHTING WATTAGE PER WA NREC TABLE 15-1 FORM LTG—LPA (2,615 SF X 1.2 = 3,138 WATTS MAX ALLOWABLE) LIGHTING SCHEDULE / LEGEND SCALE; N/A x x / IHOP (4,150 SF) (INCL. 327 SF CORR.) 104 FITNESS OUTLET (2,874 SF) (INCL. 78 SF CORR.) 100 CHIPOTLE (2,546 SF) (INCL. 225 SF CORR.) 108 DRESS BARN (7,440 SF) 112 SOUTH CENTER SQUARE BUILDING "S" REFERENCE PLAN SCALE: 1" = 20'-0" 116 41> LANE BRYANT (7,104 SF) 124 128 WHAT THE PHO (3,001 SF) 132 J x 136 0 0 PROPOSED BLACK BEAR FROZEN YOGURT 0 0 0 0 EXISTING GREASE TRAP/INTERCEPTOR 0 0 0 0 0 0 0 0 EXIST'G PANERA BREACI 152 • DEC ,VA 201 • -O -o REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION 41, RECEIVED CITY OF TUKWILA --0 APR 1 0 2013 PERMIT CENTER NORTH DS DAA Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206. 617 .9010 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIII ill Note Date Author Description Stamp 7402 REGISTERED AR , ITECT VID SOVA STA ASHINGTON Copyright © 2012 David Sova Protect Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Reference Plan Scale: As Noted Drawn by: Date: Sheet Number: DS 11/301'12 Checked by: Job Number: A0.2 0 0 0 rJr- EXISTING FLOOR PLAN / DEMO PLAN SCALE: 1/4" = 1'-0" GYP CEILING SOFFIT 0 9'-0" AFF TO BE REMOVED (ALONG WITH SUSPENDED CEILING TILE AND GRID) EXPIR DEC 2011 1?)- I I') REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER NORTH DS DAA Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206.617.9010 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 11111111111 Note Date Author Description Stamp 7402 REGISTERED AR , ITECT YID SOVA STA *ASHINGTON Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Existing Floor Plan Scale: As Noted Drawn by: Date: Sheet Number: DS 11/30/12 Checked by: Job Number: A1.0 MEZZANINE PLAN SCALE; 1/4" = 1'-0" 0 0 0 1'-9" OPEN TO BELOW a1J OPEN TO BELOW EXPIRED oEc :1y zo5 NORTH 12'-10" 12'-5" O L.:FIREPLACE 090 O } iiIII ii _1^. pito\i{a tt 5 1 t ictiilttjjtiti{ ii 11i11t"tiiitiia1 t lii • ■. 1111 .; 1..ta11.#� 1 0 38" AFF .. 0 IMP f —11- -I —It — _ '1� I f� n PROPOSED FLOOR PLAN SCALE; 1/4" = 1'-0" D 0o FIREPLACE 1 1 1 7-1 Separate Mechanical Permit required for: Coolers, freezers, walk-in coolers and freezers. Self-contained "plugin" type coolers or freezers shall not require a mechanical permit. IBC 1004.3 POSTING OF OCCUPANT LOAD. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION DS DAA Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206.617.9010 III 111111111111111111111111111111111111111111111111111111 1 11111111111 nV Note ate Author Description Stamp 7402 REGISTERED AR , ITECT VID SOVA STA •'*ASHINGTON Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: ENLARGED PLAN 15/A3.2 13'-3 1/2" 13'-3 1/2" 13'-8" RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER NORTH Proposed Floor Plan Scale: As Noted Drawn by: Date: Sheet Number: DS 11/30/12 12 Checked by: Job Number: A1.1 MEZZANINE FURNITURE PLAN SCALE; 1/4" = 1'-0" 0 0 0 OPEN TO BELOW OPEN TO BELOW crinr irAff.-11 r 11 71771.1 1111 \ \ 11111,11 111, • g 1,1r, —11\ crsa 11 11 1111 .11 I 11 11;1111111. 1 \ IT 11 1 \ 1\111 \\11\11:1111:11 1111n 1111,01.10.000.0. wmpamtwAwi 1.11 1.) • V.a101111111111 01.000 litta ialoP FURNITURE PLAN SCALE; 1/4" = EXPI KC 14 204 ti13-113 NORTH REVIEWED FOR !PODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER NORTH DS DAA Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206 . 617 . 9010 11111111111111111111111111111111111111111111111111111 11111111111 lIIuiuuuuuuIuIn 111 Note Date Author Description Stamp 7402 REGISTERED AR ITECT VID SOVA STA WASHINGTON Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Furniture Plans Scale: As Noted Drawn by: Date: Sheet Number: DS 11/30/'12 Checked by: Job Number: A1.2 OPEN TO BELOW MEZZANINE ELECTRICAL PLAN SCALE; 1/4" = 1-0" 0 0 0 0 • OPE \ TO BELOW ELECTRICALPLAN SCALE; 1/4" = 1'-0" FIREPLACE Q,?Q / r, 1, 11.11.111 11111%0\ \ N tool\ " '1 gm yrrt,_......1011117111101101111 \ (NIL 111.1,4 V:411111111' FIREPLACE T —11- 11 — —IT — EE IL_ _II EXP IRE DEC .11k gig NORTH (3fl3 REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER NORTH DS DAA Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206 . 617 . 9010 Note Date Author Description Stamp 7402 REGISTERED AR ITECT VID SOYA STA WASHINGTON Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Electrical Plans Scale: As Noted Drawn by: DS Checked by: Date: 11/30/12 Job Number: Sheet Number: A1.3 1— a OPEN TO BELOW MEZZANINE FINISH PLAN SCALE; 1/4" = 1'-0" 0 0 0 FINISH PLAN SCALE; 1/4" = 1'-0" 3' INT REFER TO 7/A0.2 FOR FINISH SCHEDULE 3' i-. EXT .r DOOR SCHEDULE EXTSF q'T3 1 1 1 LP1 1 1 I l EpT3 RUN PATTERN NORTH—SOUTH OPEN TO BELOW TAG TYPE DOOR SIZE THICKNESS MATERIAL FRAME FINISH HARDWARE REMARKS 100 INT 3'-0" x 7'-0" 1 3/4" HM HM PAINT A EXISTING TOILET ROOM 101 EXT 3'-0" x 7'-0" 1 3/4" HM HM PAINT B EXISTING EXTERIOR METAL DOOR 102 INT 3'-0" x 7'-0" 1 3/4" HM HM PAINT A EXISTING TOILET ROOM 103 INT 3'-0" x 7'-0" 1 3/4" HM HM PAINT A NEW: EMPLOYEE WORK AREA 104 EXTSF 3'-0" x 7'-0" 1 3/4" ALUM ALUM ALUM B EXISTING EXTERIOR ALUM STOREFRONT DOOR HARDWARE GROUP A HAGER BB1279 4.5 NRP BALL BEARING HINGES SCHLAGE F40ELA PRIVACY LOCK SET GLYNN—JOHNSON FB -13 X 630 FLOOR STOP SCHLAGE "NEPTUNE" 626 FINISH HARDWARE GROUP B EXISTING BUILDING STANDARD HARDWARE NEW PEMKO BULB SEALS AND SWEEP (OR SIM) 0 N 0 LS1 PT3 REFER TO 7/A0.2 FOR FINISH SCHEDULE ketwisavial PT3 LP1 OLIN PATTERN 111cRTH—SOUTH PT3 -1 7 NORTH EX IRE DEC 14:201j REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION DS DAA Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206.617.9010 111111111111111111111111111111111111111111111111111111 11111111111 Note Date Author Description Stamp 7402 REGISTERED AR , ITECT ID SOVA STA ASHINGTON Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER NORTH Finish Plans Scale: As Noted Drawn by: DS Date: 11/301'12 Checked by: Job Number: Sheet Number: A1.4 MEZZANINE CEILING PLAN SCALE; 1/4" = 1'-0" "T" BAR CEILING GRID 0 ±9'-0" AFF USG WASHABEL "CLIMAPLUS" VINYL COATED GYP TILES OVER PREPARATION AREAS 9 1/2" l't / EQ EQ REVIEWED FOR 'CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION 10 1 0 L5 O L5 O- Mi 22" 3' EQ X1 cNi cn 01-5 \ Mi 0L5 X1 T1 ----a1 T T1 T1 T1 EQ O ALIGN W/FURNITURE 0 est 0 L5 OL5 OL5 QL1 3'-7 1/2" QL1 1'-3" 2' - 7" '-8 1/2" REFLECTED CEILING PLAN SCALE; 1/4" = 1'-0" REFER TO 5/A0.2 FOR LIGHTING SCHEDULE r 5" L X ITT1 OL5 7T1 TT1 HT1 OL5 OL5 OL5 .eL OL5 OL5 OL5 OL5 OL5 // L1 r OL5 O L5 O L5 OL5 OL5 L1 L 1 [L1 r OL5 5" '/// 0L5 5" OL5 5'-3" T20 2'-2" T20 0 ALIGN 1N/FURNITURE 0L4 O O O L4 n x1 2009 IBC MEANS OF EGRESS ILLUMINATION 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. 1006.2 Illumination level. The means of egress illumination level shall not be less than 1 foot-candle at the walking surface. 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways... 3. Exterior egress components... 4. Interior exit discharge elements... 5. Exterior landings...for exit discharge doorways... DS DAA Plan Finance Design Build 249 80th Avenue SE ercer Island, WA 98040 6.617.9010 2009 IBC MEANS OF EGRESS ILLUMINATION 1006.4 Performance of system. Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle and a minimum at any point of 0.1 foot-candle measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ration of 40 to 1 shall not be exceeded. 5" 1 NORTH ELECTRICAL CONTRACTOR SHALL PROVIDE THE FOLLOWING IN COMPLIANCE WITH WA NREC SECTION 1513 & 1514: 1513.1 LOCAL CONTROL OCCUPANCY SENSORS NEAR DOOR IN TOILET ROOMS MASTER SWITCHES PER SECTION 1513.2 1513.2 AREA CONTOL(S) MAX OF 3, LOCATE CONTROLS WITHIN PREP AREA 1513.3 DAYLITE CONTROL NOT REQUIRED IN RETAIL SPACES OR AREAS WHERE FOOD IS BEING PREPARED 1513.6.1 OCCUPANCY SENS. MAX 30 MINUTE LIMIT, LOCATE OVERRIDE IN PREP AREA 1513.8 COMMISSIONING LIGHTING CONTROLS SHALL BE TESTED TO VERIFY THAT THE SYSTEMS FUNCTION AS INTENDED, REVIEW NREC SECTION 1416 FOR ACCEPTABLE TEST METHODOLOGY. PROVIDE REPORT DOCUMENTING COMPLIANCE TO TENANT AND/OR ARCHITECT 1514 EXIT SIGNS MAX 5 WATTS PER SIGN (NOTED ON LIGHTING SCHEDULE) EXP I E DEC 203 KEY NOTES: O PAINT EXPOSED CEILING/ROOF STRUCTURE 2O PAINTED GYP CEILING (WASHABLE) O WALK IN FREEZER BELOW 0 SEE SHEET A0.2 FOR LIGHTING SCHEDULE O USG "CLIMAPLUS" VINYL COATED GYP TILES USG "FROST" PANEL WITH "FL" EDGE be RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER NORTH Note Date Author Description Stamp 7402 REGISTERED AR , ITECT VID SOVA STA •'WASHINGTON Copyright © 2012 David Sova Protect Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Reflected Ceiling Plans Scale: As Noted Drawn by: Date; Sheet Number: DS 11/30/'12 Checked by: Job Number: A1.5 ` P J o J J N 01 O O O • 1 i J J \ 1 OPEN TO STRUCTURE O O O O _i J — J — J — 1 2' O 0 0 \ _ / / Li Li L1 0 0 zcNI 0 — —M io 1 L L1 L1 L1 7_1J J - " . IN` d REFER TO 5/A0.2 FOR LIGHTING SCHEDULE r u co 3'-6" 1 MEZZANINE CEILING PLAN SCALE; 1/4" = 1'-0" "T" BAR CEILING GRID 0 ±9'-0" AFF USG WASHABEL "CLIMAPLUS" VINYL COATED GYP TILES OVER PREPARATION AREAS 9 1/2" l't / EQ EQ REVIEWED FOR 'CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION 10 1 0 L5 O L5 O- Mi 22" 3' EQ X1 cNi cn 01-5 \ Mi 0L5 X1 T1 ----a1 T T1 T1 T1 EQ O ALIGN W/FURNITURE 0 est 0 L5 OL5 OL5 QL1 3'-7 1/2" QL1 1'-3" 2' - 7" '-8 1/2" REFLECTED CEILING PLAN SCALE; 1/4" = 1'-0" REFER TO 5/A0.2 FOR LIGHTING SCHEDULE r 5" L X ITT1 OL5 7T1 TT1 HT1 OL5 OL5 OL5 .eL OL5 OL5 OL5 OL5 OL5 // L1 r OL5 O L5 O L5 OL5 OL5 L1 L 1 [L1 r OL5 5" '/// 0L5 5" OL5 5'-3" T20 2'-2" T20 0 ALIGN 1N/FURNITURE 0L4 O O O L4 n x1 2009 IBC MEANS OF EGRESS ILLUMINATION 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. 1006.2 Illumination level. The means of egress illumination level shall not be less than 1 foot-candle at the walking surface. 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways... 3. Exterior egress components... 4. Interior exit discharge elements... 5. Exterior landings...for exit discharge doorways... DS DAA Plan Finance Design Build 249 80th Avenue SE ercer Island, WA 98040 6.617.9010 2009 IBC MEANS OF EGRESS ILLUMINATION 1006.4 Performance of system. Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle and a minimum at any point of 0.1 foot-candle measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ration of 40 to 1 shall not be exceeded. 5" 1 NORTH ELECTRICAL CONTRACTOR SHALL PROVIDE THE FOLLOWING IN COMPLIANCE WITH WA NREC SECTION 1513 & 1514: 1513.1 LOCAL CONTROL OCCUPANCY SENSORS NEAR DOOR IN TOILET ROOMS MASTER SWITCHES PER SECTION 1513.2 1513.2 AREA CONTOL(S) MAX OF 3, LOCATE CONTROLS WITHIN PREP AREA 1513.3 DAYLITE CONTROL NOT REQUIRED IN RETAIL SPACES OR AREAS WHERE FOOD IS BEING PREPARED 1513.6.1 OCCUPANCY SENS. MAX 30 MINUTE LIMIT, LOCATE OVERRIDE IN PREP AREA 1513.8 COMMISSIONING LIGHTING CONTROLS SHALL BE TESTED TO VERIFY THAT THE SYSTEMS FUNCTION AS INTENDED, REVIEW NREC SECTION 1416 FOR ACCEPTABLE TEST METHODOLOGY. PROVIDE REPORT DOCUMENTING COMPLIANCE TO TENANT AND/OR ARCHITECT 1514 EXIT SIGNS MAX 5 WATTS PER SIGN (NOTED ON LIGHTING SCHEDULE) EXP I E DEC 203 KEY NOTES: O PAINT EXPOSED CEILING/ROOF STRUCTURE 2O PAINTED GYP CEILING (WASHABLE) O WALK IN FREEZER BELOW 0 SEE SHEET A0.2 FOR LIGHTING SCHEDULE O USG "CLIMAPLUS" VINYL COATED GYP TILES USG "FROST" PANEL WITH "FL" EDGE be RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER NORTH Note Date Author Description Stamp 7402 REGISTERED AR , ITECT VID SOVA STA •'WASHINGTON Copyright © 2012 David Sova Protect Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Reflected Ceiling Plans Scale: As Noted Drawn by: Date; Sheet Number: DS 11/30/'12 Checked by: Job Number: A1.5 9 1/2" PLAM FINISH (PL1) PAINTED GYP WALL & STEEL STUDS (ATTACH SHELF TO STUDS) ADVANCE TABCO DI -1-35 SS SINK SET INTO SELECT STAINLESS 2SLB-24 TABLE BEVERAGE-AIRE WTR48A REFRIGERATED WORK COUNTER ON 6" CASTORS ATLAS METAL WCMD 3 COLD FOOD PAN - DROP IN SET INTO COUNTER TOP SS WORK COUNTER & SINK SCALE; 3/8" = 1'-0" TOIET FIXTURES TOILET: KOHLER "WELLWORTH" CLASSIC TWO-PIECE ELONGATED 1.28 GPF TOILET 12" ROUGH -IN MODEL # K-3575 COLOR WHITE (LEFT SIDE HANDLE) HANDLE: KOHLER POLISHED NICKEL (CHROME FINISH) K -9380 -L -SN SEAT KIT: KOHLER GRIP -TIGHT "CACHET" Q3 - COLOR WHITE - K-4636-0 SINK: KOHLER "SOHO" WALLHUNG, K-2053, COLOR WHITE FAUCET: KOHLER "TRITON" (3 HOLES) 8" SPREAD (CHROME FINISH) K -7471 -K -CP NOTES: 1. http://www.us.kohler.com/us TOILET ROOM FIXTURES SCALE; N/A 9 1 /2" DISTRESSED / ROUGH SAWN CEDAR CRUMB TROUGH "BARNWOOD" AESTHETIC, CLEAR STAIN SEALER (REQUIRED BY HEALTH DEPT) �T. 3/4 BRACKETS ® 24" O.C. TYP 1.0 CRUMB TROUGH SCALE; 6" = 1'-0" PAINTED GYP WALL & STEEL STUDS ()TTACH SHELF TO STUDS) (POS) L ATLAS METAL WCMD-3 COLD FOOD PAN (POS) WARMS S CASH DRAWER SELF SERVICE REFRIGERATED OPEN AIR SCREEN CASE CASH DRAWER OBLIQUE POINT OF SALE SCALE; 3/8" = 1'-0" Jr OBLIQUE REQUIRED ACCESSORIES A. B. C. D. E. F. G. H. J. K. 36" SS GRAB BAR 18" SS VERTICAL GRAB BAR 42" SS GRAB BAR SS TOILET PAPER DISPENSER SS SANITARY NAPKIN DISPOSAL (WOMEN'S ROOM ONLY) SS TOILET SEAT COVER DISPENSER SS PAPER TOWEL DISPENSER SOAP DISPENSER INSULATED DRAIN COVER FOR LAVATORY MIRROR WITH SS FRAME KOALA BABY CHANGING STATION NOTES: 1. MINIMUM CLEARANCES FOR ACCESSIBILITY ARE FROM FACE OF FINISHED GYP. 2. FIXTURES/ACCESSORIES SHALL MEET IBC SECTION 1109 & ICC/ANSI A117.1. 3. PROVIDE SOLID BLOCKING FOR WALL MOUNTED EQUIPMENT & GRAB BARS (250# MAX LOAD) 4. THE CLEAR FLOOR SPACE FOR A FIXTURE MAY NOT OVERLAP THE CLEAR FLOOR SPACE REQUIRED FOR ANOTHER FIXTURE, EITHER AT THE FLOOR LEVEL OR ABOVE IT. PER ICC A117.1 SECTIONS 304.3.1, 304.3.2, 603.2.2 & 604.3.2. 5. IN A SINGLE OCCUPANT TOILET ROOM, THE DOOR CAN SWING INTO THE REQUIRED MANEUVERING SPACES, AS LONG AS A WHEEL CHAIR PARKING SPACE OF [30"X48"] IS PROVIDED PAST THE SWING OF THE DOOR PER IBC SECTION 1109.2.1.6, ICC A117.1 SECTION 603.2.3 EXCEPTION 2. TOILET ROOM ACCESSORY NOTES SCALE; 3/8" = 1'-0" ENLARGED PLAN DETAIL SCALE: 3/8" = 1'-0" AAAAAAAAA PL1 COUNTER (MELAMNE) SERVING BAR SCALE; 3/8" =11-0" ENLARGED PLAN DETAIL SCALE; 3/8" =11-0" 1 10,-0" 1 1 1 TRUE TUC -36 REFRIGERATOR FREEZER 1 { 1 M stNQ T W CO U f BACK BAR HOSHIZAKI KM -101 BAH ICE MAKER MUST REMOVE THE 6" LEGS TO FIT UNDER COUNTER SCALE; 3/8" = 1'-0" TOILET ROOMS PROVIDED BY LANDLORD UNDER SEPARATE PERMIT EXP oEc:L\ 20; X 13 - 1 13 REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER DS DAA Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206.617.9010 IIII11111111111111111111111111111111111111111111111111111 11111111111 Note Date Author Description Stamp 7402 REGISTERED AR , ITECT VID SOVA STA • ASHINGTON Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Enlarged Floor Plan Scale: As Noted Drawn by: Date: Sheet Number: DS 11/30/12 12 Checked by: Job Number: A1.6 TAYLOR C723 ADA COMPLIANT SOFT SERVE MACHINE SS TRIM BY DSL INC. ±3/4" CLEARANCE ALL SIDES N 14) co TAYLOR C723 SOFT SERVE MACHINE SCALE; 1 1/2" = 1'-0" 33.89" Ir) Lv4 ±26.78" SIDE VIEW ±5.45" / / TAYLOR C723 SOFT SERVE MACHINE SCALE; 1 1/2" = 1'-0" ri JJV wO-.9 I R 11VN1 JO dOl n BR AT WIT CE CH SE E STRUT IN 4'— LS WITH 25 GA GALV STE RELY TO STRUCTURE EVERY 8'-0". ST 0" 0` INTERSECTIN STU /#10 S TS ARE WALLS It STRUTS; REWS (MIN) T REQUIRED F. SUSPENDED T—BAR CEILING GRID 8'-6" AFF UNLESS NOTED OTHERWISE 5/8" TYPE GWB 350S125-27 GALVANIZED STL STUD CSD 16" O.C. MAX HEIGHT 16'-0" PER SSMA TECHNICAL INFORMATION PAGE 14 "INTERIOR WALL LIMITING HEIGHTS" SPSF:L/120 GALV STEEL TRACK (MATCH STUD GA) SET IN (2) CONTINUOUS BEADS OF SEALANT, ANCHOR TO CONCRETE WITH HILTI XC POWDER ACTUATED FASTENER & STL WASHER AT MAX 2'-0" 0.C. 6" RUBBER COVE BASE TYP. EXISTING CONCRETE SLAB STRUCTURE PARTITION WALL BRACE SCALE; 1 1/2" = 1'-0" 26.91" 23.31" 0 FRONT VIEW s ai N • OPTIONAL VERTICAL AIR EXHAUST DUCT N 0 7 TAYLOR LINE SCALE; 3/8" = 1'-0" iO 0 EX IRE DEC 14 205 REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION TAYLOR LINE SCALE; 3/8" = 1'-0" NOTE: STAINLESS TRIM BY DSL CONTACT TRENT BARBRE phone: 206.209.2862 email:tbarbre®dsltnc.com CO RECEIVED TUKWILA APR 1 0 2013 PERMIT CENTER DS DAA Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206.617.9010 1111111111111111111111111111111111111111111111111111 1 11111111111 Note Date Author Description Stamp 7402 REGISTERED AR , ITECT STA VID SOVA AsHINGTON Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Enlarged Floor Plan Scale: As Noted Drawn by: DS Checked by: Date: 11/30/12 12 Job Number: Sheet Number: A1.6.1 4" MIN LAP 11 11 I VENT CAP CLASS "B" DOUBLE WALL SS VENT STORM COLLAR ROOF PATCH OVER METALFLASHING CONE. SET CONE IN (2) HEAVY BEADS OF SEALANT EXISTING RIGID INSULATION EXISTING ROOF DECK AIR GAP PER MANUFACTURER VENT DETAIL SCALE; 1 1/2" = 1'-0" ROOF PLAN SCALE: 1/4" = 1'-0" �: �•Rj r�£� �.::v:.�- �'3:z �wx� rya -_'�;, PROPOSED BLACK BEAR YOGURT ' ���•'�:.`�� I S tel 4 ..;pis :r ..x 'Z. �'�\� t :i♦ `•.d..i'a<=:.`. isb`•^z.`n,.ri`Tiiji;.'a...'-: Ao Dom :Iii w.. fY fK na • b..'c:'ff!3ii1�:iidii �i'i�`.:fi"u�t�1,:g vP.'a�',u':n'>#Y� +�Su . • �''t:).C.fiS..iiT.,<ai:' . tNi+Y w:cn*. '• H SATELLITE IMAGE - ROOF SCALE: NOT TO SCALE D,cc�iY.ti NOTE: MECHANICAL CONTRACTOR SHALL BALANCE THE HVAC SYSTEMS AND PROVIDE REPORT TO THE TENANT AND/OR THE ARCHITECT DOCUMENTING THE SYSTEMS PERFORMANCE / 1 NO OTHER IN'TAI E OR EXHAUST 1 AIR DEVICES ALOWED WITHIN 1(Y OF TI- IS INTAKE HRFP ..ACE f, t t!? 0 � /' NEW 5 TON TRANE GAS FIRED ROOF TOP UNIT 7 I / / / S 7 YKE REMOTE GLYCOL PAK GP— ELEC 208V/8.7A SINGLE PHASE,_,__:t t t k t 50"L X ..221 '�t;500�" t.t t. ,} .S trt C, TRS Ilio tti{ ,. tt i tt' aS' liii t t` t t tit t.tt - t t... ti t INSTALL PER MANUFACT yRw F3 I S SHALL SPAN A rt . t• , 0 ;t r.. KEEP AIR INTAKE ;10i V u } r..--' -_ - t t l i, is _.. 'F'V`�� tur z4i ' t \r'\=iiii \\\\ ; t i i ii i� A"11111 t \\ 1 a..ir / EXISTING 3 TON ROOF TOP UNIT II ..tl. Il. \ AIR INTAKE NO OTHER INT E OR EXHAUST AIR DEVICES I ALOWED WITHIN 10' OF JIjIS INTAKE / / k BEAR NORTH DEC I. Z03 REaJIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER NORTH Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206.617.9010 1 19 him 111111111111111 11 Note Stamp Date Author Description 7402 REGISTERED AR , ITECT VID SOVA STA ASHINGTON Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Roof Plan Scale: As Noted Drawn by: Date: Sheet Number: DS Checked by: 4/5P13 Job Number: A1.7 CEILING ® 12'-0" AFF m 1- • I I I `111F"\ II 1\ .1 I %IMP" V".41M _\ r .ALALA- / TOILET ROOM O 1 ao T117 tQ T1 / .111111r.; sEFaa=s�WRNTsH" MEZZANINE SEATING AREA U 9 1 -H TJI STRUCTURE TJI STRUCTURE SELF SERVE CUP SHELF _ O L1� (P12) L1 L1 L10 (PLY) CUSTOMER SEATING (,EMPLOYEE ACCESS INTERIOR ELEVATION / SECTION LOOKING WEST SCALE; 1/4" = 1'-0" 1 4\ I L4 ■ L4 ■ U _ C -H SELF SERVE FROZEN YOGURT MACHINE AND TOPPING LINE MEZZANINE SEATING AREA 1.11 MIMI MO MI•1111111111111111111. 1111•111.1••• 1111MLINIMI E1111 6111;11 !MI NA 7Ui• !:1 NI POINT OF SALE & COFFEE PICK—UP �} VAC 1 ��y y CUSTOMER SEATING 1 L1 1 L1 CUSTOMER SEATING — FUNRITURE GROUPS INTERIOR ELEVATION / SECTION LOOKING EA\ST SCALE; 1/4" = STAIR TO MEZZANINE • CUSTOMER SEATING — FURNITURE GROUPS • L4 ANTLER CHANDELIER 6" RUBBER BASE TYP kl TOILET ROOM DEC.] 203 (3•- 113 EXISTING ELECTRIC CIRCUIT B :.t IEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER II DSDAA Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206.617.9010 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIUIII Illlnwnnn n Note Stamp Date Author Description 7402 REGISTERED AR , ITECT VID SOVA STA ASHINGTON Copyright © 2012 Davld Sova Protect Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Interior Elevations Scale: As Noted Drawn by: DS Checked by: Date: 11/301'12 Job Number: Sheet Number: A2.0 OPEN TOP TO VENT WARM AIR FROM REFRIGERATION COMPRESSOR NORLAKE KLB 7468—C WALK IN FREEZER 250S125-27 GALVANIZED STL STUDS ® 24" O,C. 5/8" GYP ONE SIDE ONLY (#4 PAINTED FINISH) SET SILL TRACK WITH DOUBLE SIDED FOAM TAPE nc SECTION THROUGH GYP SOFFIT OVER WALK IN FREEZER SCALE; 1" = 1'-0" "T" BAR CEILING GRID @ 9'-O" AFF I � I TRUE T23F REACH IN FREEZER FRP 6'-0" AFF (FRP) 3" PVC OR ABS AIR INTAKE AND EXHAUST PIPES RUN TO BUILDING EXTERIOR SEPARATE EXHAUST AND INTAKE OPENINGS BY 12" SLOPE VENT TUBES TO DRAIN (INSTALL PER MANUFACTURERS INSTRUCTIONS) COLD WATER SUPPLY IN GAS SUPPLY IN RHEEM—RUUD HIGH VOLUMNE, COMMERCIAL GAS FIRED, TANKLESS WATER HEATER INSTALL PER MANUFACTURES INSTRUCTIONS AND IN COMPLIANCE WITH LOCAL CODES GAS SUPPLY SHUT OFF VALVE (SEDIMENT TRAP BELOW) COLD WATER SUPPLY (LINE IN) SHUT OFF VALVE HOT WATER SUPPLY (LINE OUT), PRESSURE RELIEF VALVE, SYSTEM DRAIN VALVE (HOSE BIB CONNECTION) SS HAND SINK (ADVANCE TABCO) PARTIAL HEIGHT WALLS WITH FRP BOTH SIDES OF MOP SINK (2 1/2" 25 GA STL STUDS) SS 3 COMPARTMENT SINK, WITH DRAIN BOARDS EITHER SIDE CHROME PLATED SERVICE SINK FAUCET WITH WALL BRACE CONDENSATE DRAIN TUBE INTO MOP SINK 20"X20"X8" MOP SINK AND FAUCET 6" RUBBER BASE TYP TANKLESS HOT WATER HEATER / MOP SINK / 3 COMPARTMENT SINK SCALE; 1/2" = 1'-0" TOP OF WALL 16'-0" AFF LINE OF HALLWAY T BAR CEILING BEHIND LINE OF TOILET ROOM GYP CEILING BEHIND SUSPENDED LIGHTING RUBBER BASE TYP L4 -H OPEN BACK WALL, OPENING TO TOILET ROOMS AND BACK EXIT SCALE; 1/4" = 1'-0" STAIRCASE TO MEZZANINE FIREPLACE BEYOND i FRONT ENTRANCE SCALE; 1/4" =11-0" BOOK/DISPLAY SHELF BOOK/DISPLAY SHELF BOOK/DISPLAY SHELF PLAM CASEWORK EXISTING STEEL TRUSS ROOF STRUCTURE SCREEN WALL BEYOND STEEL HAND/GUARDR EX`1,ED MEZZANINE STRUCTURE STRUCTURAL COLUMN PLAM CASEWORK DEC zoo REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER DS DAA Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206. 617. 9010 1111111111111111111111111111111111111111111111111111 11111111111 Note Date Author Description Stamp 7402 REGISTERED AR , ITECT VID SOVA STA ASHINGTON Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Interior Elevations Scale: As Noted Drawn by: DS Checked by: Date: 11/30/12 12 Job Number: Sheet Number: A2.1 L_-- ROSSETO WALL MOUNTED TOPPING DISPENSERS ROSSETO SERVING SOLUTIONS 1 *W*.rosseto.com CONTACT : STEPHEN A. BRENNER PHONE : 847.763.1215 x 234 EMAIL : stephen@rosseto.com 3" X .060" ALUM SPACER 3FORM VARIA "ECORESIN" TRANSLUCENT PANEL "BEAR GRASS LITE" 1/2" THICK CONTACT : MARNIE PENNINGTON SEATTLE, WA 98134 PHONE : 206.445.5257 EMAIL : marnie.pennington®3—form.com 6'-0" X 1 1/4" SQ .120" WALL ALUM TUBE .060" ALUM BACKING PLATE WITH BREAK FORMED TOP AND BOTTOM FLANGES ATTACH WITH SCREWS ROSSETO WALL MOUNTED TOPPING DISPENSERS ROSSETO SERVING SOLUTIONS 1 *w W.rosseto.com CONTACT : STEPHEN A. BRENNER PHONE : 847.763.1215 x 234 EMAIL : stephen@rosseto.com DISTRESSED / ROUGH SAWN CEDAR CRUMB TROUGH "BARNWOOD" AESTHETIC, CLEAR STAIN SEALER (REQUIRED BY HEALTH DEPT) 1/2%1/2" REVEAL JOINT (PAINT BLACK) BASE CABINET PLAM FINISH (PL1) TYPICAL RUBBER BASE (RB1) LJ 3/8" 0 THREADED ANCHOR EPDXY SET INTO CONCRETE SLAB. MIN 3" EMBEDMENT ROSSETO ISLAND SIDE VIEW SCALE; 1 1/2" = 1'-0" 1/4" 2'-6" 2'-6" 5'-2" EQ. 2' —1 3/4" 2'— 1 3/4" EQ. N • r K SC CO '0"0"0 /n\ ROSSETO ISLAND TOP VIEW SCALE; 1 1/2" = 1'-0" 0 LL -----T I I 11 u 11 u ROSSETO ISLAND BACK VIEW SCALE; 1 1/2" = 1'-0" 11 u • .060" ALUM BACKING PLATE WITH BREAK FORMED TOP AND BOTTOM FLANGES ATTACH WITH SCREWS METAL MOUNTING BRACKETS FROM ROSSETO �X( yr \ EXPEID DEC 111 201 NO EXPOSED HARDWAR ON CABINET DOORS t REVIEWED FOR CODE COMPLIANCE APPROVED An 3 0 2013 City of Tukwila BUILDING DIVISION M N • 11 u ROSSETO ISLAND FRONT VIEW SCALE; 1 1/2" = 1'-0" 11 u bTh- 113 RECEIVED CITY OF TUKWILA APR 10 2013 PERMIT CENTER DS DAA Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206 .617.9010 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 1111111111111 111 Note Date Author Description Stamp 7402 REGISTERED AR , ITECT VID SOVA STA ' ASHINGTON Copyright © 2012 David Sova Protect Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Detail / Rosseto Island Scale: As Noted Drawn by: Date: Sheet Number: DS 11/30/'12 Checked by: Job Number: A3.0 O O ► �� JQ. .. 4& MAX watmoommilot p 2.,MAxTYp• "T" BAR CEILING LATERAL BRACING CLUSTER AND SUSPENSION WIRE KEY NOTES; 10 LATERAL BRACING CLUSTER: (4) 12 GA. GALV SOFT—ANNEALED MILD STEEL WIRES SECURED TO MAIN RUNNER WITHIN 2" OF CROSS "T" AND SPLAYED 90 DEGREES FROM EACH OTHER AT 45 DEGREES MAX. ABOVE HORIZONTAL. CLUSTERS PLACED 12'-0" O.C. X 8'-0" AND 4'-0" MAX. FROM EACH WALL. WIRES SHOULD BE TAUGHT WITHOUT CAUSING CEILING TO LIFT. 0 PROVIDE VERTICAL SEISMIC COMPRESSION STRUT (MIN 3/4" DIA. CONDUIT) ® 12'-0" 0.C. EACH DIRECTION. SECURE WIRE TO MAIN RUNNER WITHIN 2" OF CROSS "T". CONDUIT TO OCCURE AT EVERY LATERAL BRACING CLUSTER AND SUSPENSION WIRES TO OCCURE AT 4'-0" 0.C. MAX EACH WAY. O FASTEN RUNNER TO PERIMITER WALL ANGLE AT (2) ADJACENT SIDES 40 RUNNER ENDS AT OPPOSITE WALLS FLOAT FREE ON PERIMITER ANGLE CEILING GRID SEISMIC BRACING 5/8" PLYWOOD DECKING s 1 � t to \ \ PLASTIC LAMINATE COUNTER TOP & EDGES (PL1) 42" TALL CUSTOMER BAR BEYOND ESPRESSO MACHINE COUNTER BEYOND FMP 117-1128 SS WASTE CHUTE 6" DIA (7" FLANGE) 5" TALL TRASH CAN BY OWNER RUBBER BASE TYP DISHWARE CONDIMENT STATION - TRASH SCALE; 1" = 1'-0" to \ \ to \ \ PLASTIC LAMINATE COUNTER TOP & EDGES (PL1) TYP 42" TALL CUSTOMER BAR BEYOND SS NAPKIN DISPENSERS, CONDIMENT CONTAINERS AND STIR STICKS BY OWNER DISHWARE TRAY BY OWNER STORAGE RUBBER BASE TYP DISHWARE CONDIMENT STATION - STORAGE SCALE; 1" = 1'-0" GALV. STL LEDGER TRACK SECURED TO STRUCTURE GYP CEILING: TOILET ROOMS SCALE; 1 1/2" = 1'-0" STEEL GUARDRAIL BASE TOP OF PARTITION ±16'— 0" AFF 5/8" TYPE GWB 350S125-27 GALVANIZED STL STUD © 16" 0.C. MAX HEIGHT 16'-0" (PER SSMA) GALV. STL LEDGER TRACK SECURED TO NEW STL STUD PARTITIONS TOILET RM CELING 9'-0" AFF 600S162-33 GALV STL JOIST ® 24" 0.C. GWB CEILING CSD 8'-6" AFF ENGINEERED PLYWOOD DECK PER STRUCTURAL SCREWED AND GLUE TO JOISTS SIMPSON "STRONG TIE" ENGINEERED WOOD HANGER PER STRUCTURAL ENGINEERED WOOD JOIST PER STRUCTURAL "T" BAR WIRE HANGERS MECHANICAL / LIGHTING SPACE USG DX/DXL DONN 15/16" GRID (OR SIM) SET "T" BAR SO THAT THE FACE OF THE USG "FROST" CEILING TILE ALIGNS WITH THE BOTTOM OF FINISHED "BEAM" MEZZANINE CEILING SCALE; 1 1/2" = 1'-0" COMPOSIT BEAM PER STRUCTURAL \ \ 2'-6" t1'-0 II t0 BLACK MELAMINE INTERIOR PLASTIC LAMINATE COUNTER TOP & EDGES (PL1) ONE ADJUSTABLE SHELF BLACK MELAMINE FACES AND PVC EDGE BAND TYP RUBBER BASE TYP to SELF SERVE TOPPING PUMP STATION SCALE; 1" = 1'-0" 2'-6" 2" \ \ BLACK MELAMINE INTERIOR PLASTIC LAMINATE COUNTER TOP & EDGES (PL1) 16"X16" APG CASH DRAWER BY REVEL SYSTEMS (*W*.revelsystems.com) FLUSH MOUNT FOOD SCALE FROM REVEL SYSTEMS (***.revelsystems.com) ONE ADJUSTABLE SHELF BLACK MELAMINE FACES AND PVC EDGE BAND TYP RUBBER BASE TYP P.O.S. COUNTER SCALE; 1" =11-0" 3'-6 1/2" PL1 COUNTER TOP & EDGES t0 M 2" ;ATLAS METAL WCMD-3 COLD FOOD PAN SET INJO COUNTER TOP 2'-4 1/2" CLEAR BLACK MELAMINE INTERIOR J tJ FIXED SUPPORT PANEL COLD TOPPING COUNTER SCALE; 1" = 1'-0" —8" to M G PLASTIC LAMINATE COUNTER TOP & EDGES (PL1) 10" PLAM 1 1/2" 2'-8 1/2" SERVING BAR SCALE; 1" = 1'-0" "RAKKS" BRACKETS (OR SIM) SUPPORT COUNTER TOP ***:rakks.com 1.800.826.6006 REMOVEABLE FINISH PANEL(S) EMPLOYEE SIDE MDF/PLAM/MELAMINE BAR HEIGHT LEGS (BOLTED ASSEMBLY) EXPOSED SCREWS (EMPLOYEE SIDE) RB1 VYNIL BASE TYP BOTH SIDES 4'-O" MAX HEIGHT M 2'-6" '-0" '-0" 1J I 00 ,04 N 2" BLACK MELAMINE INTERIOR F to PLASTIC LAMINATE COUNTER TOP & EDGES (PL1) ONE ADJUSTABLE SHELF BLACK MELAMINE FACES AND PVC EDGE BAND TYP RUBBER BASE TYP _ ALTERNATE TOPPING PUMP STATION SCALE; 1" = 1'-0" 1'-0" 0 2'-6" \ REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION PLASTIC LAMINATE (PL1) EXTERIOR AND EDGE BAND BLACK MELAMINE INTERIOR, TYP FRP OVER GYP BOARD WALL PLASTIC LAMINATE COUNTER & EDGE (PL1) "RAKKS" BRACKETS (OR SIM) SUPPORT COUNTER TOP WWW:rakks.com 1.800.826.6006 KM -101 BAH ICE MAKER (REMOVE/REPLACE THE FACTORIES 6" LEGS SO IT WILL FIT UNDER THE COUNTER) BACK BAR - ICE MAKER SCALE; 1" = 1'-0" 2'-6" 00 M \ FRP OVER GYP BOARD WALL DSDAA Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206.617.9010 Note Date Author Description Stamp 7402 REGISTERED AR , ITECT VID SOVA STA ASHINGTON LAMINATE COUNTER TOP & EDGES (PL1) Copyright © 2012 David Sova EX!I E DEC 114 20g "RAKKS" BRACKETS (OR SIM) SUPPORT COUNTER TOP *WW:rokks.com 1.800.826.6006 RECEIVED CITY OF TUKWILA BACK BAR SINK SCALE; 1" = 1'-0" APR 1 0 2013 PERMIT CENTER Protect Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Details / Casework Sections Scale: As Noted Drawn by: DS Checked by: Date: 11/30/12 12 Job Number: Sheet Number: A3.1 HANDRAIL ISOMETRIC ASSEMBLY DIAGRAM SCALE; 1" =11-0" 1 1/2" DIA STL TUBE RAILINGS 3'-6" TO GUAR 3'-O" TO HAN 11" 1 1/2" 0 TUBE RAILINGS 1/2" 0 TUBE WELDED TO FLAT BAR STOCK ANGLE STOCK UPRIGHTS BOLTED TO BRACKETS MACHINE SCREWS ATTACH RAILING (2) 1 1/2" x 1 1/2" x 3/16" STEEL ANGLES 4x6x 3/16" STEEL ANGLE WELDED TO UPRIGHTS 1 "x 1 "x 1/8" STEEL ANGLE (WELDED IN PLACE) PROVIDES SUPPORT FOR WELDED WIRE GRID 3"x3"x 3/16" WELDED WIRE GRID WELDED IN PLACE WELD UPRIGHT BASE PER STRUCTURAL 1"x1"x 1/8" STEEL ANGLE (WELDED IN PLACE) PROVIDES SUPPORT FOR WELDED WIRE GRID 750S125-27 GALV STEEL JOIST 1'- " CUSTOM FABRICATED STEEL BALUSTERS WITH WELDED WIRE SCREEN 3/4" AC PLYWOOD FINISH FLOOR DECK (A SIDE UP) 3/4" CD PLYWD SUBFLOOR BUILT UP PLYWOOD SKIRT BOARD PAINTED 5/8" GYP 350S125-27 GALV STL STUDS 16" O.C. TYP BUILT UP PLYWOOD STAIR TREADS & RISERS 11" TREAD 1" NOSE TYPICAL TYPICAL STAIR SECTION SCALE; 1" = 1'-0" EXIST'G CONC STRUCTURE 1/2" 1 1/2" DIA STL TUBE GUARDRAIL 1 1/2" DIA STL TUBE GUARDRAIL j m r VARIES EQ EQ ±5 5/8" PARTIAL ELEVATION STEEL HANDRAIL DETAIL SCALE; 1 1/2" = 1'-0" 3'-2" CLEAR 7 EQUAL TREADS SECTION 1 1/2" DIA STL TUBE GUARDRAIL & HANDRAIL RAIL'G BRACKETS 1/2" 0 TUBE WELDED TO FLAT BAR (2) BOLTS TO ATTACH RAILING BRACKETS 1 "x 1 "x 1/8" STEEL ANGLE (WELDED IN PLACE) PROVIDES SUPPORT FOR WELDED WIRE GRID RAIL'G BRACKETS 1/2" 0 TUBE WELDED TO FLAT BAR MACHINE SCREWS ATTACH RAILING 3"x3"x 3/16" WELDED WIRE GRID WELDED IN PLACE (2) 1 1/2" x 1 1/2" x 3/16" STEEL ANGLES 1 "x 1 "x 1/8" STEEL ANGLE (WELDED IN PLACE) PROVIDES SUPPORT FOR WELDED WIRE GRID 4x6x 3/16" STEEL ANGLE WELDED TO UPRIGHTS WELD TO STRUCTURE (REF TO ENGINEERING DOCS) 1'-0" 11" TREAD 111 IFP 0 0 0 II 0 II 0 0 0 0 2'-9" CLEAR 2'-9" CLEAR 0 11 L 0 II E$PI IE.P DEC 1' :Z01 COIEV!rIE�•WVED FOR DE COMPLIANCE AP!ROVED i APR 3 0 2013 City of Tukwila G DIVISION LANDING 10 EQUAL TREADS ENLARGED PLAN OF THE STAIR SCALE: 1" = 1'-0" RECEIVED /CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER DSDAA Plan Finance Design Build 2249 80th Avenue SE Mercer Island, WA 98040 206.617.9010 Note Date Author Description Stamp REGISTERED AR , ITECT VID SOYA STA ° ASHINGTON Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: Details / Stairs / Railing Scale: As Noted Drawn by: DS Checked by: Date: 11/301'12 Job Number: Sheet Number: A3.2 GENERAL NOTES 1. The service requirements shown on these plans are for food service equipment specified by Black Bear Yogurt. These plans are prepared and furnish for the purpose of indicating equipment service requirements and rough -in spotting locations only and do not relieve the General Contractor, Sub - Contractors, or other involved trades of the responsibility of the above parties to consult with the architect, owner, or his representative, concerning all other requirements of the building. 2. All miscellaneous parts and items including grease traps, grease interceptors, faucets, valves, traps, trim, wiring, magnetic starter, disconnects, electrical panels, thermal overload protection, cords, and plugs, etc. are supplied by the appropriate subcontractor unless otherwise specified on these plans or by separate written contract. 3. Plumbing, electrical, and refrigeration rough -in and final connections and hook-up shall be provided and performed by the respective subcontractors in compliance with applicable national, state, and local codes. All rough -ins are subject to change and verification pending the final selection and location of all equipment. 4. The General Contractor shall provide and install the proper backing for wall and ceiling mounted equipment, shelving, brackets, braces, table cantilever bases, stool cantilever brackets, hand railing, etc. As required and indicated on the Black Bear Yogurt specifications and equipment brochures. 5. All items noted "existing, vendor, future, by other, and NIC (not in contract)" shall be verified by the respective subcontractor for size and requirements prior to rough -in and final connection. 6. The General Contractor shall provide non-combustible, one (1) hour -rated (minimum) wall(s) behind and adjacent to cooking equipment as required by national, state, and local codes and ordinances. 7. The General Contractor shall provide floor, wall, ceiling, and roof penetrations, and sleeves for refrigeration, syrup, inert gases, Glycol line(s) to accommodated the requirements and proper installation of all food service equipment. 8. It shall be the responsibility of the General Contractor to provide weather protection for all roof, floor and wall penetrations prior to and during the installation of the food service dealer's equipment and furnishings. 9. It shall be the responsibility of the General Contractor to properly seal all floor, roof and wall penetrations as required after the installation of the food service dealer's equipment and furnishings. 10. It shall be the responsibility of the General Contractor to notify Owners of any corrections, comments, or revisions on the plan set as approved for building permit, immediately upon receipt of said plans and permit, prior to site construction. All dimensions shown on these plans are measured from finished walls, floor, ceiling, and/or centerlines of utility rough -ins. The sub -contractors shall make necessary allowances for finishes during rough -in as required. HEALTH DEPARTMENT CRITERIA WATER & SEWER: EMPLOYEES: EQUIPMENT: INTERIOR WALL SURFACES: LIGHTING: FOOD: HAND WASHING: SINKS & LAVS: FAUCETS: FLOOR SINKS: WATER HEATER: STORE HOURS: NOTE: City of Tukwilla 3 All equipment is NSF approved Smooth finish & FRP wainscot in rest rooms and 2' above all food counter areas and sinks New or Existing with min. of 20 foot candles (215 lux) of light in all food prep areas and 10 foot candles (100 lux) in storage areas. Shatter shields will be provided in food, work and storage areas. 100% Carry -Out of pre-packaged, single service disposable beverage containers. A wall mounted single service towel and soap dispenser shall be provided at each hand sink All sinks and lavatories shall be supplied with hot (min. 120 degrees F) and cold running water under pressure with a 2" air gap between discharge and floor sink. All sinks and lavatories shall comply with EHP-883. All faucets shall have a combination faucet. Mop sink faucet shall have an anti -siphon device All floor sinks shall be easily accessible and cleanable Water Heater shall be a On demand Unit commercial type and provides 5 GPM @140* and 1.5 gpm to 120* water to hand sinks Store hours shall be a maximum of 16 per day. Store is open from 7:00 a.m. to 10:00 p.m. mon. - sun. 24 hours notification to the health department is required for all inspections prior to store opening. Project must meet county and state health department regulation criteria. SITE MAP VACANT (2,024 S.F.) IEEE GREASE INTERCEPTOR IE=12.1 ISI • CARTERS (4,000 S.F.) C c 17 iI I'al ly.l J 7 V4� eoa 0 00 . .•i ■ 0 nkler Blvd. Black Bear Yogurt A Specialty Desert & Coffee House 17250 Southcenter Parkway Tukwilla, WA 98188-3301 SOUTHCENTER SQUARE BSIP Parcel No. 788892-0020 GENERAL INFORMATION STORE LOCATION: LOCATION REFERANCE: TUKWILLA STREET ADDRESS: 17200 SOUTHCENTER PARKWAY SUITE: 148 CITY TUKWILLA STATE: WA ZIP: 98188-3301 TENANT INFORMATION: DBA: STREET ADDRESS: SUITE: CITY: STATE: ZIP: PHONE: FAX: CONTACT EMAIL: LANDLORD INFORMATION: COMPANY NAME: CONTACT: STREET ADDRESS: CITY: STATE: ZIP: PHONE: FAX: EMAIL: Ass TEAM SUPERINTENDANT: COMPANY: CONTACT E-MAIL: BUSINESS PHONE: ADDRESS: BLACK BEAR YOGURT 5700 100th ST SW 330-152 LAKEWOOD WA 98499 (253)-212-7882 ZACH MILLER zachmiller768@gmail.com WIG PROPERTIES LLC ANJALI WIG 4811 134TH PL SE BELLEVUE WA 98006 425.644.6126 425.865.8648 anjaliuwig@wigproperties.com ZACH MILLER BLACK BEAR YOGURT zachmiller768@gmail.com (253) 292-1260 5700 100TH ST S.W. SUITE 330-152 LAKEWOOD WA 98499 ARCHITECT OF RECORD: DAVID SOVA (AIA 7402) COMPANY DSDAA 2249 80th Ave SE Mercer Island WA, 98040 (206) 617-9010 CODE REQUIREMENTS CODE ANALYSIS (PER 2006 I.B.C.) FLOOR AREA CALCULATIONS: SEATING AREA: PREP AREA: STANDING LINE: RESTROOMS & LOBBY: TOTAL USEABLE FLOOR AREA: OCCUPANT LOAD CALCULATION SEATING AREA: 1/15 sq.ft. STANDING LINE. PREP AREA: 1/200 sq.ft. RESTROOMS: 1/100 sq.ft. TOTAL OCCUPANT LOAD: OCCUPANT CLASSIFICATION: BUILDING CONSTRUCTION TYPE: BUILDING IS: Exterior wall construction: BUILDING IS FULLY SPRINKLERED: DEC •11-k 2015 1554 square feet 348 square feet 123 square feet 105 square feet 2130 square feet 103 25 2 1 131 A2 (IBC303.1) TYPE -II -B Steel Roof Deck, Steel Trusses, CMU Construct <20' (existing) YES REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION THIS DRAWING AND ALL INFORMATION CONTAINED HERE -IN IS THE CONFIDENTIAL PROPERTY OF BLACK BEAR YOGURT. AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND/OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH ACTION BY OTHERS FOR ANY PURPOSE, EXCEPT WITH THE WRITTEN PERMISSION OF BLACK BEAR YOGURT AND 3-D DESIGN SERVICES. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND TO AGENTS OF 3-D DESIGN SERVICES AND OR THE BLACK BEAR YOGURT COMPANY. C 113 RECEIVED ITY OF TUKWIL APR 1 0 2013 PERMIT CENTER DESIGN SERVICES 3D Design Services BLACKBEAR YOGURT \441M0 00 Cf) OWNER JESSE ROBERGE (020) 393-3180 jessebbyl @gmail.com SHEET SIZE D size (36"x24") SCALE: 1/4"=1'0" (UON) BACKGROUND BY: David Sova DAVIDSOVA@ COMCAST.N ET DESIGN 0Y: Zach Miller (253)292-1260 GRAFTER: 3-D Design Services Clyde Langworthy (360) 769.3970 KC -0 KC -1 KC -2 KC -3 KC -4 KC -4.1 KC -9 INDEX COVER PAGE EQPT. PLAN PLUMBING PLAN ELECTRICAL ELEVATIONS ELEVATIONS II 3D VIEWS Revision/Issue BACKGROUND Date 10/18/12 PROPOSED LAYOUT 11/05/12 SUBMITTAL SET 12/04/12 date: 12/4/2012 3:57:27 PM Sheet KC -0 2 (44) 20" PLUMBING NOTE: SEE ATTACHED GREASE INTECEPTOR DATA AND FL I RATES L EQUIPMENT PLAN 1/4" = 1'-0" EQUIPMENT SCHEDULE 1 Mark Count Description Manufacturer Model 1 3 DISPENSER CUP DISPENSE -RITE BFL-3 2 6 MACHINE YOGURT TAYLOR COMPANY C-723 SOFT SERVE 4 1 SHELF CUSTOM WS -08-60 5 1 HOSE REEL T&S BRASS 2985 5.1 1 FCT. WALL MT, MIXING T&S BRASS ORK-1 5.2 1 BACK FLOW PREVENTER KIT T&S BRASS ORKS 6 2 FIREPLACE FMI PRODUCTS LVF43NR 7 1 WALK-IN COOLER NOR -LAKE WI -6-7 8 2 SHELVING FOCUS FF1860G 8.1 1 SHELVING FOCUS FF1836G 11 1 SINK MOP JOHN BOOS EMS -2016-6 11.1 1 CHEMICAL SHELF ADVANCE TABCO K-245 11.2 1 FAUCET UTILITY T&S BRASS B-0665-BSTP 13 1 WALL MT FAUCET T&S BRASS B-1128 14 1 3COMP SINK EAGLE GROUP 314-16-3-18 14.1 1 PREP RINSE FAUCET, WALL MT T&S BRASS B-2278 14.2 3 LEVER DRAIN T&S BRASS B-3950 16 1 FREEZER, REACH -IN TRAULSEN G12010 17 1 DESK CUSTOM TBD 18 2 LOCKERS WINHOLT WL -66 19 1 GREASE INTERCEPTOR SCHIER PATG-35-LO 22 2 SHELVING FOCUS FF1448C 23 1 SINK SINGLE COMP EAGLE GROUP 2424-1-16/4 25 26 ROSSETO DISPENSERS EZ SERV 5W 25.1 27 ROSSETO DISPENSERS EZ SERV H50 26 1 COLD PAN DI WELLS RCP -300 26.1 18 1/6TH PANS VOLRATH DROP-IN PANS 27 1 SNEEZEGUARD BSI ADJUSTABLE 29 2 FOOD WARMER SERVER PRODUCTS 81230 30 2 HAND SINK, WALL MT-W/FCT. ADVANCE TABCO 7 -PS -60 30.1 2 SOAP & TOWELS BOBRICK B-40, B-4262 31 2 POS SYSTEM REVEL SYSTEM IPAD-REVEL 32 1 COFFEE DISPENSER BY VENDOR VERIFY 33 1 RAZZLE BLENDER TAYLOR BC10 34 1 DUMP SINK, DROP-IN ADVANCE TABCO (21" X 15W) DI -1-10 34.1 1 FAUCET, DECK 4" O.C. FISHER 3526 35 1 ICE MAKER ICE-O-MATIC ICEU150FA 36 2 BLENDER BLEND TECH SMOOTHERI5Q 37 1 REFR DISPLAY & GRAB -N -GO FEDERAL SSRC5052 38 1 REFR UNDERCOUNTER TRUE TUC -48 39 1 WORK TOP REFER TRUE TWT -48 40 2 WAFFLE BAKER, ELECTRIC WELLS WB -1 41 1 20in RD COFFEE TABLE MILLWORK CTB20 42 3 WASTE RECEPT. TBD TBD 43 1 FREEZER UNDERCOUNTER TRUE TUC -27F 44 2 ESPRESSO MACHINES WEGA GEMINI 45 1 32in RD COFFEE TABLE MILLWORK CTB32 46 1 SPECIAL TABLE CARVED MILLWORK CUSTOM 47 7 32in RD BAR TABLE MILLWORK 32in RD BAR TABLE 48 1 32in RD BAR TABLE MILLWORK 32in RD BAR TABLE 49 1 TABLE 30X118 JH CARR 30x96 ADA1 1 LAV GRAB BAR BY OWNER TBD ADA2 1 LAV GRAB BAR BY OWNER TBD EP 1 ELECTRIC PANEL BY EC TBD FD 2 FLOOR DRAIN BY P.C. 5" RD. FSI 1 FLOOR SINK BY P.C. 8" SQ FS2 1 FLOOR SINK BY P.C. 8" SQ HWH 1 WATER HEATER ON DEMAND RHEEM TANKLESS GT-199PVM1 K32) K40)- ( IC) • 11111'I'IIIuiIq•I lIIIIi I , +Ill ll'!I I III11'v 36 34 34.1 K44) ;: ►ItII111IIIMkDal_ it l eu..�••ue 31�1� .�••u� 1� I :1 I �I I I IIHIII.11 II SII �� ��II► SII e III MI 42 ®FRONT COFFEE BAR 1/2" = 1'-0" 1 I L" 111141 Cii�ci:::EII::i NUMB iuuuu e�uur I± 5OROSSETO STATION & COLD PANS 1/2" = 1 0 PERSPECTIVE AT FRONT OF HOUSE OBACK LINE & FRONT SECTION 1/2" = OBOH @ WALK-IN 1/2" = 1'-0" \ ‘---1" Walk-in Cooler 1/2" = 1'-0" REVIEWED FOR CODE COMPLIANCE • APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA PERMIT CENTER KEY PLAN 1/8" = DESIGN SERVICES BLACKBEAR YOGURT IESSE ROBERGE (620) 393-3100 Jossebbyl©gmoil.com 0 M M 00 00 00 -�C ca SHEET SIZE D size (36"x24") SCALE: 1/4"=1'0" (UON) BACKGROUND BY: David Sova DAVIDSOVA@COMCAST.NET DESIGN BY: Zach Miller (253) 292-1260 DRAFTER: 3-D Design Services clydelang@gmail.com r INDEX -. KC -0 COVER PAGE KC -1 EQPT. PLAN KC -2 PLUMBING PLAN KC -3 ELECTRICAL KC -4 ELEVATIONS KC -4.1 ELEVATIONS II KC -9 3D VIEWS 1 Revision/Issue Date BACKGROUND 10/18112 PROPOSED LAYOUT 11105112 SUBMITTAI SFT 12104112 date: 12/4/2012 3:57:38 PM ROOF MTD.GP-3 REFRIGERATION UNIT AIRDYNE4, T': ERV D PIP COOLANT MAP4IFOL. ROOF MTD. GLYCOL COMPRESSOR RACK VIEW TO GREASE INTERCEPTOR ITEM SALES NO. DESCRiPTION 1 002b35�25 AWS g a I 14'7464;3 ){stJPTx Firyv4'; 6 Ht.s4.0 MIMI B.0463 vo 6 .O1 ). )1 BRArS:414.4 uzn*;y; 6" W )I 44 . "FMB filar W66E6nr. Anh-Ra • " T&S BACKFLOW PREVENTER (HOSE REEL REQUIRED W/MIXING FCT.) r PLUMBING NOTES 1. PLUMBING PLAN SHOWS ROUGH -IN AND CONNECTION LOCATIONS WITH DIMENSIONS AND CAPACITIES. PLUMBING CONTRACTOR RESPONSIBLE FOR CODE REQUIREMENTS & MODIFICATIONS. 2. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY VALVES, TRAPS, TAIL PIECES, LINE STRAINERS, PRESSURE REDUCING VALVES, VACUUM BREAKERS, TRAP PRIMING DEVICES, AND CONNECT ALL WATER, AND WASTE LINES TO FOOD SERVICE AND BEVERAGE EQUIPMENT. 3. PLUMBING CONTRACTOR SHALL INSTALL AND CONNECT ALL FAUCETS FURNISHED WITH FOOD SERVICE AND BEVERAGE EQUIPMENT. 4. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL INDIRECT WASTE LINES FROM FOOD SERVICE AND BEVERAGE EQUIPMENT TO FLOOR DRAINS AND SINKS AND INSULATE WASTE LINES FROM ICE BINS, EVAPORATORS AND BAIN MARIES. 5. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ADA BATHROOM COMPLIANCE AND BE FAMILIAR WITH LOCAL CODES & REQUIRMENTS. GREASE INTERCEPTOR (GB -35): 1.) 3" INLET/OUTLET 2.) MAX. FLOW RATE: 35GPM 3.) LIQUID CAPACITY: 35 GAL 4.) GREASE CAPACITY: 142 LBS. (20 GAL) 5.) MAX SOLIDS: 6 GAL. 6.) wEIGHT W/ STD. COVER: 90 LBS. 7.) 2000 LB LOAD RATED 8.) MAX OPERATING TEMP.: 190 deg. F CONTINUOUS GAS CONNECTION NOTE: AN ACCESSIBLE GAS CONNECTION AT FIREPLACE MUST HAVE MANUAL SHUT-OFF VALVE INSTALLED AT OUTLET OF GAS SUPPLY PIPING SYSTEM UPSTREAM OF THE CONNECTOR SHUT-OFF VALVE PER CSA B149.1: ANSI Z223.1 NATURAL GAS & PROPANE INSTALLATION CODES fi r�. 3,, ^F 'ter' s� Cap* 6 F•'rr t >r „ '. $PEGtPiCATiflNS P4s,Sam , ., ,.. .� '' "s ✓J,.r S t : 5ot.}"9Rt:ffNI94121M1.1111111 Ft3C r rt„. (I L 566 r ,x+s W'a91411as) SCIil6L F .FPV+ Rhe Cs= 13 .YSxiG ib`3 10 i%IUC (3uL3 X53 PI&£213`31e3 CD.0c:I N,cle 7 Ox 1 :� :Ot&I Dry 2U Nkt Sd S1 EL . xs3 ' Sa53'sd 1. rrh. (.'w ch..rs; 3 I 1,5 ®®®©�®�® 17 32 t5: � :8•sz 3E'e. 164< 4§'t b __ 15 40 18" 2 3 1 2,3 23'r. I5,Ai 13:z: 11 3i4. 131/2 5 5- 503 :R' 113 PATG-15.00 SEE CUT SHEET 60 10. 2 3" 7:3 Eu] t6§'4: L 414 7.. 3:!4 53, 566 E .13 PATG-1820 j�� 70 ®® SINK MOP -3" 1 2, 3' ��®�®�®®®�® 0 3 179 5 675.20{0 1 \'tib 2i © / '�: 14 ®®®®® '•MEMMEll STUB @ 8" SPREAD / 36" AFF 13 225 PATG•2025 �12:0131 18 1/2 3 ®MMI 231' 25'1 "30. 13 105.. 16. 754 6:'i 503 33 •257 561042420: s13 18 2 7 ®I��® 27 . 125. AIR GAP ®®�M 1 PREP RINSE FAUCET, WALL MT - 1/2 63 MI 5635.5810. 3Sl itL. h �1M�1E!�M ax'R ®`�11 :d VAIIIMIN �<t; s/ 3t 1, ---": ® ,.4> ice. 14.2 osw ITI ,,✓k i r;,qo�, ®®1112111® s'.4r.,a;31s ,'2r3+�-, wL, :,: MINAMC11•111131-01116.70"AlliNernineilligraitital' I,''n`.a �, m.6...i o,, r a. r . ■lit i=`k. r-: a i cl I kl i k PATG3058 IIII,mQi 0113417 ` ®®®®®�®®E 2 16 •'A4 DAT5304.0 5 0 .28 ' dl N �® 04 241i 165.. 6T 9.'1 1 52 s 500 70. 412 114.1563224 '6{t 138 110011111111111113.111111M1����38 44 i'2 26 32'3' 21 11 25Y1 63'4 ds 5R7 10. Cd1 DATC.3415 73. 170 WA WA Iiia© 310 " :5.. 1 3;d li L 20,- 3204 I 02 I] 10125 26Ya 61, /6{•,�s�: IIIf�RI 500 .14'2 '105 162 - 1.037 AATG3420. 336450 .592025.& PATG3050 ate 06:51134416 ASIA A112,1464 933 5 136 6y:603 PATG-1412 through PATG•3628 FE H C 43yitterlltod0s ass: fro u`a7urcd37 cania13311.1501:51aii2A1.4. w Profile Model (-LO Suffix) GREASE TRAP SPECIFICATIO 0 -3D -1 a 20' - 1 1/2" 3' - 11 1/2' "9 31-g" 2'.0" I EMESSOJ tl• TRAWS TRAWS UC BEER 4-6 :c) CO FE HOT & COLD WATER (8" SPREAD) HOT & COLD WATER (4" SPREAD) CV HANDS] WASTE, DIRECT -CONNECTED. UNLESS NOTED "OPEN HUB" FLOOR DRAIN, TRAP PRIMER INDIRECT WASTE CONNECTION N M 7 GAS CONNECTION . ip ent Shu o 1 VMS':Wit 1 8 NPT Tp r`r 359 int Natural Gas: Frr.G ter (519WC*9 to Pressure) Proparia/LP From lydterr-aI ReJui t r. (01`' W to. 4" Pressure). 7\ Cap Pipe Tee Nipple Joint l Sediment Trap (SEE SPECIFICATION. SHEET 6-B FOR DETAILS) PLUMBING Mark Count Description CW -SIZE CW -AFF HW -SIZE HW -AFF ID -SIZE ID -AFF DD -SIZE DD -AFF GAS -SIZE MBTUH GAS -AFF PLUMBING REMARKS 2 6 MACHINE YOGURT HOSE REEL 3/8 72 ROOF MTD GLYCOL REFRIGERATION "AIRDYNE" COMPRESSOR( CENTERED ABOVE TAYLOR LINE (HOT & COLD) 5 1 5.1 1 FCT. WALL MT, MIXING 1/2 72 1/2 72 1/2" C IN, 1/2" H IN, - 3/8" OUT/SEE KC-4.1VIEW 21 FOR OPTIONS 5.2 1 BACK FLOW PREVENTER KIT 3/8 38 SEE CUT SHEET 6 2 FIREPLACE 1/2 40,000 44 FLEX CONNECTOR TO FIREPLACE GAS FITTING 11 1 SINK MOP 0 3 11.2 1 FAUCET UTILITY 3/4 36 3/4 36 STUB @ 8" SPREAD / 36" AFF 13 1 WALL MT FAUCET 1/2 18 1/2 18 PREP SINK FCT.- AIRGAP TO FS 14 1 3COMP SINK 1/2 18 1/2 18 2 16 AIR GAP 14.1 1 PREP RINSE FAUCET, WALL MT - 1/2 18 1/2 18 ATTACHED TO 3COMP 14.2 3 LEVER DRAIN 2 16 �, ATTACHED TO 3 COMP PRIOR TO INSTALL - AIRGAP TO FS E AT SHEET AIR GAP TO FS/OPTIONAL RE �' A • cl GREASE INTERCEPTOR 0113417 ` 2 16 PREP SINK K SINGLE 30 2 HAND SINK, WALL MT-W/FCT. 1/2 21 1/2 21 1-1/2 26 SEE KC -4.1 VIEW 19 32 1 COFFEE DISPENSER 1/2 44 VENDOR SUPPLIED 34 1 DUMP SINK, DROP-IN 2 16 AIRGAP TO FS 35 1 ICE MAKER 3/8 30 3/4 15 SELF CONTAINED, UNDERCOUNTER - AIRGAP TO FS 44 2 ESPRESSO MACHINES 1/2 28 LEAD W/ WATER SOFTNER - SEE SPEC'S. FD 2 FLOOR DRAIN 3 -7 BY P.C. FS1 1 FLOOR SINK 3 -3 BY P.C. FS2 1 FLOOR SINK 3 -3 BY P.C. HWH 1 WATER HEATER ON DEMAND VERIFY GT-199PVM1 RHEEM COMPORABLE 0 z 00 m (Z tud0 0 (A J Z Z a¢ WWW c1.7C 0wo Q 11.1 ceO (5) Peg 00 e.s/9- I / cs LI M" 2/C1- i� /LCEM I I VIEW TO GI (ABOVE GR SEE VIEW T 37P - o a F.- -n % .,.. mfo:� fir, 6 3 EASE INTERCEPTORt• 4,-(":";r,:;:1--::::m:;:- . DE) -HS SHEET r ll,�.q,. J 0 • ▪ • 1' HOSE BIB FOR COOLING MANIFOLD EMERGENCY CITY WATER DUMP/FLUSH f`:,,F/r»iisslr: rIH,•.,'r../...../.::^.%/rrrr/rII/rinYl.:/,/r;/!l(/rrrri N SWJhivJ,C¢x3 WILL !JOT Be l JI.JSTI7.4L 511»Lt 77 /N7-1.7 THE N (6) \ LI DEC .14 201 Ai/ 6, 6,Y E' TRAP V ( 6 /e E /-J -s'/E G / 1 0,.,veru:.cw<uurr<uw.cu+rrii.:c,�ri�: I1 9 EVIE1t'!.+ED FOR DE C©MP41ANCE APPROVED APR 3 0 2U13 City of Tul.wilt IILDING DIVISION .:0 19'-4" LAV 4' -9" 1' -4" /r 4"/r ..d.4 r ,rrr..,r. 5'-7" [0-1 r...,crr :3 3'-10" <V 7'-11" 1,1,61,51.1611.156$166,&$6161.6.6.6,6•66117.' 51, • de RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER 3'-6" Is arin�n.>3;6S3;4sI�h,4fv»»m»>i»z DESIGN SPRVICES 3D Design Services >- , I-- N o N� �� Lcn kr)z O _ _c 0 Ct c W O a N H 0 aw OU 3 BLACKBEAR YOGURT :5 09 JOWNER ESSE ROBERGE (626) 3933100 Jessobby1@gmaIl.com SHEET SIZE D size (36"x24") SCALE: 1/4"=1'0" (UON) BACKGROUND BY: David Sova DAVIDSOVA@COMCAST.N ET DESIGN BY: Zach Miller (253)292.1260 DRAFTER: 3-D Design Services clydelang@gmail.com KC -0 KC -1 KC -2 KC -3 INDEX COVER PAGE EQPT. PLAN PLUMBING PLAN ELECTRICAL KC -4 ELEVATIONS KC -4.1 ELEVATIONS II KC -9 3D VIEWS 1 Revision/Issue Date BACKGROUND 10/18/12 PROPOSED LAYOUT 11/05/12 SUBMITTAL SET 12/04/12 date: 12/4/2012 3:57:48 PM Sheet KC 2 B ELECTRICAL SYMBOLS symbol description Description FIXTURE MT'D J -BOX KW HP VOLTS FIXTURE MT'D RECEPTACLE HERTZ DIR. CONN. 1 NEMA DUPLEX RECEPT., 20 -AMP, 120V, GRD TYPE. VERTICALLY MT'D ((UON) ELECTRICAL REMARKS SIMPLEX RECEPT., 20 -AMP, 120V, GRD TYPE. VERTICALLY MT'D (UON) WALK-IN COOLER JUNCTION BOX, VERT MT Ci` SINGLE POLE SWITCH ,.' MOISTURE -PROOF LIGHT FIXTURE 4) WATERPROOF THERMOSTAT ®) SINGLE RECEPT./ 208V, GRD TYPE. VERTICALLY MT'D (UON) 84+ DATA POINT(POS/CREDIT TERMINAL) 16 HARD WIRE CONNECTION POINT FREEZER, REACH -IN 3'-1" 4'-11" ri n /,,, , ........ . WW,,'/.5W.f./h65 1,5 H.' Y///1,,,,. h%I/I.WWA /555F55.^.'/,'l.UlnY/,H. HJ/1..../.OY.SY/H/1/J,,,fffH� Sl 1„1/. 1 1w/,/wliiswlw.lf:WuwwxwW:SNl'.I'i.'lurii,rw..wwnYJ.',i,uo/wlwlllll.,vuw,nviirin.:vwwillllvl .ufb!<%J��;'b<Y/`/i////lYr, Yn Y/r,Yf/f/fii:/•N%11,5W, 2'-1" w D yaiuiaihYn; ,FmYlti if WEGA ESPRESSO MACHINE SIGNAGE CONTROLS 1. ALL EXTERIOR SIGNS SHALL BE CAPABLE OF BEING AUTOMATICALLY SWITCHED OFF DURING THE DAYLIGHT HOURS AND ON -USE NIGHTTIME HOURS BY EITHER A COMBINATION OF TIMER AND PHOTOCELL, OR A TIMER WITH ASTRONOMIC CONTROL. 2. AUTOMATIC TIME SWITCHES SHALL HAVE PROGRAM BACK-UP CAPABILITIES, WHICH PREVENT THE LOST OF PROGRAM AND TIME SETTINGS FOR AT LEAST 10 HOURS, IF POWER IS INTERRUPTED. 3. SUGGESTED MODEL: "Z" SERIES ASTRONNOMICAL TIMER BY TORK (OR EQUAL) WWW.TORK.COM 1 U LT LT 6'-1" Ifi���irurr :.S.Y/1hr5�Y,Y1/,1 • 11.0 .wrawa • ....YH111.»nw wlwllwlvA,'!.m „ '-11" 5'• 5" 5'-5" 2'-11" 1'-11" , 3'-1" 1'-3"R'-10 1' -5" . 1' -8" 1'-6" 0'-11 2'-6" 2'-3" 1'-0" 3'-4" 8'-8" W%f/!!.'lwr /1/I/,%/ Y/HH/lY1,Y1f/ff/vl. �%//Y// •.,:: ryryH%hY.y:!: 4W„1,11.:. }f.wsC ”,I. €its( 111 '1°1 ts: t t .Hrhil/AhFt011IH1/1J,; N'H/1/1. .. l 2'-9" 'i3?�71H15;•.: �l���r;5'::�S.;J.:l/J//�� •"`/'�`�l�/. JYbYI �n ./!b?zXs'i`;ii:5 cx/rJJrY bY//.'/.i5'/,'J,'WNlJ//1/.5»?Y/HH➢YH1.5'r,Y///l/.YGL/.1.,.H/f/.Yr'/.i'J.ii'iJ.SYNJJJJJJ.1.555S-1iT55..... A 7' -4" 4'-4" r.,hhv.ririH.rr.n NOTE "A" 120V, 1 PHASE, SERVICE 10.0 AMPS. STUB AS NOTED. CONNECT AT POS STATIONS. (DEDICATED CIRCUIT, ISOLATED GROUND, ADD PHONE LINE, PROVIDE EMPTY J -BOX WITH CONDUIT FOR INTERCONNECTING POS SYSTEM, CREDIT CARD, DSL, PHONE AND FAX LINE) (VERIFY ALL REQUIRMENTS WITH POS SYSTEM SUPPLIER.) NOTE ALL WALL MOUNT ELECTRICAL RECEPTICLES AND J -BOXES ARE TO BE FLUSH MOUNTED IN WALLS WITH NO EXPOSED CONDUIT SHOWING ON SURFACE OF WALLS. CONTRACTOR TO PROVIDE MINIMUM WALL FURRING IF REQUIRED. OUTLETS ARE DIMENSIONED "ON -CENTER" i 7'-6" ELECTRICAL NOTES t 10 6-2ecY ,/:Fr, 3,ru �;5;_.:ox .YHIHr✓�v: Z 6° © p Cbk 605 3'-7" tt qffffffffff,„.0.fiie 1. ELECTRICAL PLAN SHOWS ROUGH -IN AND CONNECTION LOCATIONS AND DIMENSIONS WITH CAPACITIES. ELECTRICAN IS RESPONSIBLE FOR VARIATIONS TO MEET CODE REQUIREMENTS. 2. ELECTRICAL SYSTEM IS DESIGNED FOR 120/208 VOLTS, 1 & 3 PHASE, 60 HERTZ. 4 WIRE SYSTEM. 3. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL JUNCTION BOXES, RECEPTACLES, COVER PLATES, PULL BOXES, CONDUIT AND WIRING EXCEPT WHERE NOTED. 4. ALL CONDUIT RUNS INDICATED FOR REFRIGERATION, DRINK AND LIQOUR SYSTEM LINES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. CONDUIT SHALL HAVE 24" (800 MM) MINIMUM RADIUS BENDS. 5. ELECTRICAL DIVISION SHALL FURNISH AND INSTALL EMPTU CONDUIT WITH JUNCTION BOXES FOR INSTALLATION OF OWNER SUPPLIED ELECTRONIC CASH CONTROL SYSTEMS. ELECTRICAL IN ACCORDANCE WITH OWNER AND MANUFACTURER'S REQUIREMENTS. 6. ELECTRICAL CONTRACTOR TO VERIFY INSTALLATION INSTRUCTIONS OF EQUIPMENT. 0 ; NOTE: REVEL POS SYSTEM: LOW VOLTAG ACCOMPANING EQUIPMENT:120V +DATA /,;;Y<'/1 WNW///WA./I///%/iff'1/ffffflpY///i%////,,,ii hnflfdf9Y/// /:.%%%%%/f//H/AY/G ii%�% .r.w.K!/H/d!H(NW'HKifNKf((n(vJ/rtuHH'(4//1/hfl•••••'••'••."".••,•" 11'-2" 1'-1" Yh55w,',wsrvr:: r. r. ::::::.::: Hsi Y �wtiHf{'/%'1:fHH(✓.'/.'l1.HNKHffNkWiwNw. 9'-3" • 6'-9" .....<................iira�nwu.::.....i„i,ulh 1 iijj uEc:14 2a1.3 REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION ELECTRICAL Mark Count Description AMPS KW HP VOLTS PH HERTZ DIR. CONN. CORD - PLUG NEMA AFF ELECTRICAL REMARKS 2 6 MACHINE YOGURT 18 208 3 60 Yes NO 20 3 POLE 4 WIRE - 25A BREAKER 7 1 WALK-IN COOLER 20 120 1 60 Yes 84+ SEE SHOPS 16 1 FREEZER, REACH -IN 9.5 115 1 60 No YES 5-15P 72 3WIRE+GRND. 26 1 COLD PAN DI 7 1/4 115 1 60 No YES5 - 15P 24 15A BREAK J -BOX IN CASEWORK 29 2 FOOD WARMER 8.3 120 1 60 No 5-15P 24 15A BREAK J -BOX IN CASEWORK 31 2 POS SYSTEM 15 120 1 60 YES VERIFY 24 15A BREAK J -BOX IN CASEWORK 32 1 COFFEE DISPENSER 20 120 1 60 No YES 5-15P 48 BY VENDOR 33 1 RAZZLE BLENDER 2.6 120 1 60 No YES 5-15P 48 35 1 ICE MAKER 9.7 8 115 1 60 Yes NO 32 3-WIRE+GRND REC 36 2 BLENDER 18 1151 60 No E YES _ 5-15P 48 CITY OF 37 1 REFR DISPLAY & GRAB -N -GO 10 .5 230 1 60 No YES 5-15P 12 ADD 38 1 REFR UNDERCOUNTER 5 1/5 115 60 No YES 5-15P 12 44 2 ESPRESSO MACHINES 17 220 1 60 Yes NO 48 PERMIT HWH 1 WATER HEATER ON DEMAND 30 208 Yes NO VERIFY TBD 1J 13- 113 EIVED TUKWILA K WIL A 1 0 2013 CENTER DESIGN SERVICES 3D Design Services BLACKBEAR YOGURT CO CD M M 00 00 tM w�\ CC5 / OWNER JESSE ROBERGE (626) 393-3180 jessobby1@gmail.com SHEET SIZE D size (36"x24") SCALE: 1/4"=1'0" (UON) BACKGROUND BY: David Sova DAV IDSOVA@COMCAST.NET DESIGN BY: Zach Miller (253)292.1260 DRAFTER: 3-D Design Services clydelang@gmail.com INDEX KC -0 COVER PAGE KC -1 EQPT. PLAN KC -2 KC -3 PLUMBING PLAN ELECTRICAL KC -4 ELEVATIONS KC -4.1 ELEVATIONS 11 KC -9 3D VIEWS IRevision/Issue BACKGROUND Date 10118/12 PROPOSED LAYOUT 11105112 SUBMITTAI.SFT 12/04/12 gRalcQW date: 12/4/2012 3:57:52 PM c Sheet KC -3 NAPKINS STRAWS OCUSTOMER SIDE AT ESPRESSO COUTER 1/2" = 1'-0" DESIGN SERVICES 3D Design Services LL O I— N :IS WE ,_ oc cni 17 6Z �� O D)W w ,--. 'r) NfxC7L) 1 O w Mow O(/) �0 .. 0 a N 8 0 aw W o OU 7'-8" FALSE FRONT 34 `33> (-3-6) 38 FI FI Zn 11 BLACKBEAR YOGURT CT3,_ CCT 45 00 CDV� O O CV ti M c70 00 tM W C3") cCC 11 !g" • \e . n JESSE ROBERGE (626) 393-3160 Jassebby1@gmail.com SHEET SIZE D size (36"x24") SCALE: 1/4"=1'0" (UON) BACKGROUND BY: David Sova DAV ID SOVA@ CO M CAS T.N ET DESIGN BY: Zach Miller (253) 292.1260 DRAFTER: 3-D Design Services clydelang@gmail.com O VIEW AT ENTRY TO BOH KC -0 KC -1 KC -2 KC -3 KC -4 KC -4.1 KC -9 INDEX COVER PAGE EQPT. PLAN PLUMBING PLAN ELECTRICAL ELEVATIONS ELEVATIONS II 3D VIEWS DEC 1 Ll 20g REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION Revision/Issue BACKGROUND PROPOSED LAYOUT SUBMITTAL SET Date 10118112 11105112 12/04112 / IvIIs ,�I I�IIIII�II�II�III� JI Orli IIIIPIII� IIS u LJ u RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER date: 12/4/2012 3:57:58 PM 9��� SECTION THRU SPACE \ / . 1.111 — A 1 All 13� I 1 3 1 II ai_\ NAPKINS STRAWS OCUSTOMER SIDE AT ESPRESSO COUTER 1/2" = 1'-0" DESIGN SERVICES 3D Design Services LL O I— N :IS WE ,_ oc cni 17 6Z �� O D)W w ,--. 'r) NfxC7L) 1 O w Mow O(/) �0 .. 0 a N 8 0 aw W o OU 7'-8" FALSE FRONT 34 `33> (-3-6) 38 FI FI Zn 11 BLACKBEAR YOGURT CT3,_ CCT 45 00 CDV� O O CV ti M c70 00 tM W C3") cCC 11 !g" • \e . n JESSE ROBERGE (626) 393-3160 Jassebby1@gmail.com SHEET SIZE D size (36"x24") SCALE: 1/4"=1'0" (UON) BACKGROUND BY: David Sova DAV ID SOVA@ CO M CAS T.N ET DESIGN BY: Zach Miller (253) 292.1260 DRAFTER: 3-D Design Services clydelang@gmail.com O VIEW AT ENTRY TO BOH KC -0 KC -1 KC -2 KC -3 KC -4 KC -4.1 KC -9 INDEX COVER PAGE EQPT. PLAN PLUMBING PLAN ELECTRICAL ELEVATIONS ELEVATIONS II 3D VIEWS DEC 1 Ll 20g REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION Revision/Issue BACKGROUND PROPOSED LAYOUT SUBMITTAL SET Date 10118112 11105112 12/04112 / IvIIs ,�I I�IIIII�II�II�III� JI Orli IIIIPIII� IIS u LJ u RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER date: 12/4/2012 3:57:58 PM 9��� SECTION THRU SPACE \ / . 1.111 — A 1 All 13� I 1 3 ilia_1 Frill ;I In I� A t ®Casework Section at Syrup Cabinet 1/2" = 1'-0" WALK-IN COOLER 1/4" = 1'-0" Lounge at BOH Fireplace 1/4" = 1-0" ®BOH (OPPOSITE FIREPLACE) 1/4" = 1'-0" BOH BACK OF STAIRS 1/4" = 1'-0" ©BELOW STAIRS 1/4" =11-0" OFOH AT FIREPLACE 1/4" = 1'-0" ® FRONT OF HOUSE 1/4" = 1'-0" r– BAR TOP LVL l D U.A S I 6" X 20 STRUCTURAL TIMVER SUPPORT COLUMN FLAVOR BOTTLE f i (49) 42 I 46 111 1 (44) t (27) (299> (3-1) (377) 31 N./ —Countertop Corbels Countertop Relief 1 (napkins) Drop-in Straw Containers 0 9 Section 11 1/4" = 1'-0" 10 Section 12 1/4" = 1'-0" 11 Section 13 1/4" = 1'-0" 12 Front of House Seating at Storefront 1/4" = 1-0" ,6-,-)1 Front Line-up and Mezanine Above 1/4" = 1'-0" 14 Self Service Line-up 1/4" = 1'-0" 15 Dispenser Island 1/4" = 1'-0" TYPICAL DINING CHAIRS 47 7 26 (42) O ( 4 ) TT'? TTT 11111111 �uu 11111111 LAI 11111111 r.=■ 11111111 rl=�■ 11111111 un .w 11111111 16 Rosseto Dispensers on Self -Service Line O 1/4" = 1'-0" FRONT LINE-UP AT SOFTSERV 1/4" = 1'-0" 18 STAIRS 1/4" = 1'-0" M 11. kr M 19 PREP AREA 1/4" = 1'-0" ELIASON DOOR PAPER PRODU3TS UP -FRONT S–C RAGE 92" .fl It jl NOK z J 0 0 (3-2) c4-9) (3-3) t 00 H (-3-4) 1 z 0 0 1 1 0 0 20 EMPLOYEE SIDE AT SERVICE AREA 1/4" = 1'-0" REVIEWED FOR CODS= COMPLIANCE CE f APPROVE: D APR 3 0 2013 BACKFLOW PREVENTER AIXING FAUCE nn nn \ 11 11 Hill 11111 Hill 21 BACK WALL AT SOFTSERV MACHINES Klv 1/4" = 1-0" 34 (4-4) (4-4) 1 a TAI 0 22 SECTION VIEW COFFEE SERVICE 1 /4 = 1 0 City of Tukwila BUILDING DIVISION DEC ,14 201 111■IIII111IIII11. 111■11111u1111111/ I IuI -IPI I/I I!1 I'I 1•I 11_ 1■I II111i11i1111111I a 230 KEY PLAN 2 1/4" = 1'-0" ata- 113 RECEIVED CITY OF TUKWIL APR 1 0 2013 PERMIT CENTER DESIGN SER VIC :S 3D Design Services 0 00 GO VD a0PLI Ch CT N �o M 0 N H a4-1 0 O 00 O 44L) BLACKBEAR YOGURT 00 r— Cr) JESSE ROBERGE (626) 393-3160 jessebby1@gmoil.com SHEET SIZE D size (36"x24") SCALE: 1/4"=1'0" (UON) BACKGROUND BY: David Sova DAV IDSOVA@ COMCAST.N ET DESIGN BY Zach Miller (253)292.1260 DRAFTER: 3-D Design Services clydelang@gmail.com KC -0 KC -1 KC -2 KC -3 KC -4 KC -4.1 KC -9 INDEX COVER PAGE EQPT. PLAN PLUMBING PLAN ELECTRICAL ELEVATIONS ELEVATIONS II 3D VIEWS I* Revision/Issue Date BACKGROUND 10/18112 . PROPOSED LAYOUT 11/05112 SUBMITTAL SET 12104/12 `< date: 12/4/2012 3:58:11 PM A C Sheet =i lilll■1111—� �I— Ij—I—II�� _I��'II�Ii'.�llll III 1 VIEW FROM ENTRANCE ii I 2 VIEW TO FRONT IN EMPLOYEE AREA View TO Yogurt Machines Alliikri 1_v n� I -._-_,_-_-.-,--_-_-._-i.11411:11" III ._ ® CUSTOMER SIDE AT GRAB -N GO O FRONT ESPRESSO BAR O BUILDING FRONT © ROSSETO STATION DEC V( 201y REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER ESIGN SERVICES BLACKBEAR YOGURT 00 CL) C/3 M M 00 CO CS) rJESOWNER SE ROBERGE (626) 393-3180 Jessobby1@gmail.com o` SHEET SIZE D size (36"x24") SCALE: 1/4"=1'0" (UON) BACKGROUND BY: David Sova DAV IDSOVA@ COMCAST.NET DESIGN BY: Zach Miller (253)292.1260 DRAFTER: 3-D Design Services clydelang@gmaitcom KC -0 KC -1 KC -2 INDEX COVER PAGE EQPT. PLAN PLUMBING PLAN KC -3 KC -4 KC -4.1 KC -9 ELECTRICAL ELEVATIONS ELEVATIONS II 3D VIEWS / Revision/Issue BACKGROUND 10!18!123 Date PROPOSED LAYOUT 11/05/12 SUBMITTAI SFT 12/04/12 date: 12/4/2012 3:58:21 PM General Structural Notes (THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE DRAWINGS) CRITERIA: 1. ALL MATERIALS, WORKMANSHIP, DE5I6N, AND CONSTRUCTION SHALL CONFORM TO THE DRAWIN65, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC) WITH WASHINk6TON STATE ADMINISTRATIVE CODE AMENDMENTS, 2001 EDITION. 2. DE5I6N LOADIN6 CRITERIA: OCCUPANCY CATE60RY IBC TABLE 1604.5 II FLOOR LIVE LOAD (RESTAURANT) 100 P5F STAIR LIVE LOAD 100 P5F EARTHQUAKE SEISMIC DE5I6N CATEGORY D 55= 1.42, S1=0.41, SP5=0.15, SiD= 0.41 ORDINARY STEEL MOMENT FRAMES ASCE 1-05 CHAPTER 13 RP = 1.5, op = 1.0, IP = 1.0 3. STRUCTURAL DRAWIN65 SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWIN65 AND ALL OTHER CONTRACT DOCUMENTS FOR BIDDIN6 AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. IT I5 THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE BUILPIN6 LAYOUT DIMENSIONS (6RID LAYOUTS, 5ITE COORDINATES, ETC.) AMON6ST ALL TRADES, INGLUDIN6 SHOP FABRICATED ITEMS 4. CONTRACTOR SHALL VERIFY ALL EXISTIN6 DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCIN6 ANY WORK. ALL DIMENSIONS OF EXISTIN6 CONSTRUCTION SHOWN ON THE DRAWIN65 ARE INTENDED A5 6UIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE DRAWIN65 ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWIN65 OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE DRAWIN65, OR IF THE EXISTIN6 MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENGIN6 ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACIN6 FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWIN65. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. 1. CONTRACTOR -INITIATED GHAN6E5 SHALL BE SUBMITTED IN WRITIN6 TO THE ARCHITECT AND STRUCTURAL EN6INEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHAN6E5 SHOWN ON SHOP DRAWIN65 ONLY WILL NOT SATISFY THIS REQUIREMENT. 8. DRAWIN65 INDICATE 6ENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. q. ALL STRUCTURAL SYSTEMS COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFAGTURIN6, DELIVERY, HANDLIN6, STORA6E AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLIER. 10. SEISMIC BRAGIN6 AND ANCHORA6E OF MECHANICAL OR ELECTRICAL EQUIPMENT AND OTHER MECHANICAL PIPIN6, FIXTURES, ETC. NOT SPECIFICALLY SHOWN ON THE PROJECT MECHANICAL OR ELECTRICAL DRAWIN65 SHALL BE DESIGNED BY A PROFESSIONAL EN6INEER RE6ISTERED IN THE STATE OF WASHIN6TON. THE MECHANICAL/ELECTRICAL CONTRACTOR MUST HIRE THE ENGINEER AND I5 RESPONSIBLE FOR ALL COSTS RELATED TO THE PURCHASE AND INSTALLATION OF SEISMIC BRAGIN6 AND ANCHORA6E. SEISMIC BRAGIN6 AND ANCHORA6E DE5I6N AND CONSTRUCTION SHALL COMPLY WITH CHAPTER 13 OF ASCE 1-05. SEE GENERAL STRUCTURAL NOTE <001> FOR ADDITIONAL INFORMATION. 11. SHOP DRAWIN65 FOR REINFORGIN6 STEEL, STRUCTURAL STEEL, AND EN6INCCRCD WOOD I -JOISTS SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL EN6INEER FOR REVIEW PRIOR TO FABRICATION OF THESE ITEMS. 12. SHOP DRAWIN6 REVIEW: DIMENSIONS AND QUANTITIES ARE NOT REVIEWED BY THE EN6INEER OF RECORD, AND THEREFORE MUST BE VERIFIED BY THE CONTRACTOR. THE CONTRACTOR SHALL REVIEW AND STAMP DRAWIN65 PRIOR TO REVIEW BY ENGINEER OF RECORD. SUBMITTALS SHALL INCLUDE A REPRODUCIBLE AND ONE COPY. THE REPRODUCIBLE SHALL BE MARKED AND RETURNED. SHOP DRAWIN6 SUBMITTALS PROCESSED BY THE ENGINEER ARE NOT CHANGE ORDERS. THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR I5 TO DEMONSTRATE TO THE EN&INEER THAT THE CONTRACTOR UNDERSTANDS THE DESI6N CONCEPT BY INDICATING WHICH MATERIAL I5 INTENDED TO BE FURNISHED AND INSTALLED AND BY DETAILING THE INTENDED FABRICATION AND INSTALLATION METHODS. IF DEVIATIONS, DISCREPANCIES, OR CONFLICTS BETWEEN SHOP DRAWING SUBMITTALS AND THE CONTRACT DOCUMENTS ARE DISCOVERED EITHER PRIOR TO OR AFTER SHOP DRAWIN6 SUBMITTALS ARE PROCESSED BY THE EN6IMEER, THE DESI6N DRAWIN65 AND SPECIFICATIONS SHALL CONTROL AND SHALL BE FOLLOWED. STATEMENT OF SPECIAL INSPECTIONS (STRUCTURAL): 13. STATEMENT OF SPECIAL INSPECTIONS - STRUCTURAL ITEMS (SEISMIC DE5I6N GATE6ORY D): DEFINITIONS: THE SEISMIC FORGE RE5I5TIN6 SYSTEM FOR THIS STRUCTURE CONSISTS PRIMARILY OF STEEL MOMENT FRAMES AND FLOOR DIAPHRAGMS A5 SPECIFIED ON THE DRAWIN65. SEE THE LEGEND OF PLAN SHEETS FOR ADDITIONAL INFORMATION DEFINING MEMBER LOCATIONS. SPECIAL INSPECTIONS AND TESTIN6 SHALL BE PERFORMED BY THE OWNER APPOINTED INSPECTION A6ENGY IN ACCORDANCE WITH CHAPTER 11 OF THE IBC WITH REPORTS PER IBC SECTION 1104.1.2 SUBMITTED TO THE OWNER, ARCHITECT, STRUCTURAL EN6INEER, CONTRACTOR, AND BUILDIN6 OFFICIAL FOR EACH DAY SPECIAL INSPECTIONS OR TESTING I5 PERFORMED. THESE INSPECTIONS ARE IN ADDITION TO THE INSPECTIONS SPECIFIED IN IBC SECTION 110. SEE TABLES BELOW FOR ADDITIONAL INFORMATION. STRUCTURAL ITEMS SPECIAL INSPECTION FREQUENCY IBC REFERENCE STRUCTURAL STEEL FABRICATION AND ERECTION* FABRICATION PROCEDURES PERIODIC ERECTION PERIODIC SHOP AND FIELD WELDIN6 CONTINUOUS (PERIODIC FOR ITEMS EXCEPTED PER IBC 1104.3 ITEM 2) COLD -FORMED STEEL FRAMIN6 FIELD WELDIN6 PERIODIC CONCRETE (SEE GENERAL STRUCTURAL NOTE 11 FOR ADDITIONAL REQUIREMENTS)** REINFORGI146 PLACEMENT PERIODIC AND PRIOR TO ALL CONCRETE POURS ANCHOR BOLT PLACEMENT PERIODIC AND PRIOR TO ALL CONCRETE POURS CONCRETE PLACEMENT*** CONTINUOUS CURIN6 4 FORMWORK PROCEDURES PERIODIC WOOD FASTENERS, BOLTS, STRAPS, HOLDOWNS, ETC. EPDXY GROUTED RODS OR REBAR PERIODIC FOR CONNECTIONS OF ALL MEMBERS OF THE SEISMIC AND WIND FORCE RESISTIN6 SYSTEM INGLUDIN6 DIAPHRA6M5, PERIODIC INGLUDIN6 INSPECTION OF EMBEDMENT DEPTH AND HOLE CLEANLINESS PRIOR TO ALL INSTALLATIONS 1104.2.1 4 TABLE 1104.3 ITEM 3 1104.3.2 4 TABLE 1104.3 ITEM 6 1704.3.1, TABLE 1104.3 ITEM 445, 1101.2, 4 AISG 341-06 APPENDIX 0 1104.3, 1101.4 4 ANS D1.3 TABLE 1104.4 ITEM 1 TABLE 1104.4 ITEM 3 TABLE 1104.4 ITEM 5,641 TABLE 1104.4 ITEM 8,11412 1101.3 4 1106.2"""" (SEE 1104.6.1 FOR ADDL. REQUIREMENTS AT HIGH LOAD DIAPHRA6M5) TABLE 1104.4 ITEM 4 # STRUCTURAL STEEL INSPECTIONS MAY BE WAIVED IF APPROVED BY THE OWNER AND BUILDING OFFICIAL FOR WORK PERFORMED ON THE PREMISES OF A FABRICATOR RE6ISTERED AND APPROVED TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION IN ACCORDANCE WITH IBC SECTION 1104.2.2. ** EXCEPTIONS 1 THRU 4 PER IB0 SECTION 1104.4 SHALL NOT APPLY TO CONCRETE WORK ON THIS PROJECT. ""* FREQUENCY OF CONCRETE LABORATORY TESTIN6 SHALL BE IN ACCORDANCE WITH AGI 318-08 SECTION 5.6.2 UNLESS OTHERWISE NOTED IN THE PROJECT SPECIFICATIONS. „„** THE EXCEPTION FOR SHEATHING FASTENED AT A SPACING 6REATER THAN 4"00 SHALL NOT APPLY TO WOOD OR METAL FRAMIN6 ON THIS PROJECT. ARCH, MECH, 4 ELEG ITEMS SUSPENDED CEILINGS PARTITION WALLS SEISMIC DE5I6N REQUIREMENTS (ASCE 1-05 CHAPTER 13) PERIODIC SPECIAL INSPECTION A5 SPECIFIED PER IBC CHAPTER 11 ASCE 1-05 SECTION 13.5.6 ASCE 1-05 SECTION 13.5.8 LIFE SAFETY COMPONENTS INGLUDIN6 ASCE 1-05 SECTION 13.6 AND FIRE PUMPS, EMER6ENGY 6ENERATORS, IBC 1108.4 SMOKE EVACUATION FANS, AND COMPONENTS WITH HAZARDOUS COMBUSTIBLE, OR HIGHLY TOXIC CONTENTS (Ip=1.5 PER ASCE 1-05 SECTION 13.1.3) ALL OTHER MECHANICAL AND ASCE 1-05 SECTION 13.6 ELECTRICAL COMPONENTS INSPECTIONS PER IBC SECTION 110 AND ASCE 1 13.5.6.2.2 A5 REQUIRED REQUIRED DURING ERECTION AND FASTENIN6 FOR WALLS > 15 125F (IBC 1101.6) REQUIRED FOR VERIFICATION OF CERTIFICATE OF COMPLIANCE LABEL ON COMPONENT (IBC 1101.8) NOT REQUIRED STRUCTURAL OBSERVATION PER IBC SECTION 1110 I5 NOT REQUIRED FOR THIS STRUCTURE. CONTRACTOR STATEMENT OF RESPONSIBILITY: CONTRACTOR SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY IN ACCORDANCE WITH IBC SECTION 1101 TO THE BUILPI146 OFFICIAL AND OWNER PRIOR TO CONSTRUCTION AGKNOWLED6I146 THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS. GEOTECHNICAL: 14. FOUNDATION NOTES: ALLOWABLE SOIL BEARING PRESSURE AND SOIL PROFILE TYPE ARE ASSUMED AND THEREFORE MUST BE VERIFIED BY A QUALIFIED 6EOTECHNICAL ENGINEER PRIOR TO FOOTIN6 PLACEMENT. IF SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL EN6INER FOR POSSIBLE FOUNDATION REDE5I6N. ALLOWABLE 50IL PRESSURE 3,000 PSF SOIL PROFILE TYPE SITE GLASS D ANCHORAGE: 15 EPDXY-6ROUTED RODS OR REBAR TO CONCRETE SPECIFIED ON THE DRAWIN65 SHALL BE 6ROUTED WITH ONE OF THE FOLLOWING: "SET -XP ADHESIVE" A5 MANUFACTURED BY SIMPSON STRONG -TIE COMPANY, INC. INSTALL IN STRICT ACCORDANCE WITH ICG -E5 REPORT N0. 2508, INGLUDIN6 MINIMUM EMBEDMENT REQUIREMENTS; OR "HIT-HY 150 MAX -5D" AS MANUFACTURED BY HILTI CORPORATION AND INSTALLED IN STRICT ACCORDANCE WITH IGC -E5 REPORT N0. 3013, INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. SUBSTITUTES PROPOSED BY CONTRACTOR SHALL BE SUBMITTED FOR REVIEW WITH ICG -ES REPORTS INDIGATIN6 EQUIVALENT OR 6REATER LOAD CAPACITIES. IN ADDITION, SUBSTITUTIONS SHALL MEET IGC -ES ACCEPTANCE CRITERIA AC308. PERIODIC SPECIAL INSPECTION OF EPDXY-6ROUTED ANCHOR INSTALLATION I5 REQUIRED. EPDXY 6ROUTED RODS OR REBAR SHALL NOT BE USED AS SUBSTITUTES FOR CAST -IN-PLACE ANCHOR BOLTS OR REINFORGIN6 STEEL UNLESS SPECIFICALLY APPROVED BY THE STRUCTURAL EN6INEER. NOTIFY EN6INEER IF ANCHOR LOCATIONS CONFLICT WITH REINFORGIN6 STEEL - DO NOT OUT REINFORGIN6 OR REDUCE EMBEDMENT DEPTHS WITHOUT PRIOR APPROVAL. UNLESS OTHERWISE NOTED, PROVIDE THE FOLLOWIN6 EMBEDMENT DEPTHS FOR ANCHORS AT CONCRETE: 3/44) ROD OR #5 BAR 1" RENOVATION: 16. DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. SHORIN6 SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. EXISTIN6 REINFORGIN6 SHALL BE SAVED WHERE AND A5 NOTED ON THE DRAWIN65. SAW CUTTIN6, IF AND WHERE USED, SHALL NOT GUT EXISTING REINFORCIN6 WHICH I5 TO BE SAVED. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMA6E OR OVERLOAD THE EXISTING STRUCTURE. A. ALL NEN OPENIN65 THROU6H EXISTIN6 SLABS SHALL BE ACCOMPLISHED BY SAWGUTTIN6 WHEREVER POSSIBLE. UNLESS OTHERWISE NOTED, ALL NEW OPENIN65 SHALL BE SAWGUT NEAT AND GLEAN; NO OVERGUTTIN6 AT OPENIN6 CORNERS SHALL BE ALLOWED. A5 REQUIRED, CORE DRILL CORNERS AND CHIP, 6RIND OR OUT THE CORNERS TO PROVIDE THE REQUIRED DIMENSIONS. B. CONTRACTOR SHALL VERIFY ALL EXI5TIN6 CONDITIONS AND LOCATION OF MEMBERS PRIOR TO CUTTIN6 ANY OPENIN65. CONCRETE : 11. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN AGCORDANGE WITH IBC SECTION 1g05 AND AGI 301. CONCRETE SHALL ATTAIN A 28 -DAY STREN6TH OF f'c = 4,000 P5I. MAXIMUM WATER-GEMENTITIOUS MATERIAL RATIO FOR INTERIOR SLABS SHALL BE BETWEEN 0.40 AND 0.44. ALL CONCRETE SHALL BE EXPOSURE GLASSES F0, 50, P0, AND CO PER AGI 318-08 TABLE 4.2.1 EXCEPT AS NOTED BELOW. ALL CONCRETE EXPOSED TO EARTH (FOUNDATIONS, ETC.): (F0, 50, P0, 01) ALL CONCRETE EXPOSED TO WEATHER: (F1, 50, P0, 01) CONCRETE MIXES SHALL MEET OR EXCEED THE REQUIREMENTS SPECIFIED ABOVE. MIXES SHALL BE SUBMITTED TO THE EN6INELR AND BUILDIN6 OFFICIAL FOR APPROVAL TWO WEEKS PRIOR TO PLACIN6 ANY CONCRETE AND SHALL INCLUDE THE AMOUNTS OF GEMENT, CEMENTITOUS MATERIAL, FINE AND COARSE AGGREGATE, WATER AND ADMIXTURES, A5 WELL A5 THE WATER -GEMENT RATIO, SLUMP, CONCRETE YIELD AND SUBSTANTIATIN6 STREN6TH DATA IN ACCORDANCE WITH AGI 318-08, CHAPTER 5. REVIEW OF MIX SUBMITTALS BY THE EN6INEER OF RECORD INDICATES ONLY THAT INFORMATION PRESENTED CONFORMS 6ENERALLY WITH CONTRACT DOCUMENTS. CONTRACTOR OR SUPPLIER MAINTAINS FULL RESPONSIBILITY FOR SPECIFIED PERFORMANCE. 18. REINFORCI146 STEEL SHALL CONFORM TO ASTM A615, 6RADE 60, fy = 60,000 P51. 6RADE 60 REINFORGIN6 BARS WHICH ARE TO BE MELDED SHALL CONFORM TO ASTM A706. REINFORCEMENT COMPLYIN6 WITH ASTM A615(51) MAY BE WELDED ONLY IF MATERIAL PROPERTY REPORTS INDICATIN6 CONFORMANCE WITH WELDIN6 PROCEDURES SPECIFIED IN A.W.S. D1.4 -q8 ARE SUBMITTED. Iq. REINFORGI146 STEEL SHALL BE DETAILED (INGLUDIN6 HOOKS AND BENDS) IN ACCORDANCE WITH AGI 315-11 AND 318-08. LAP ALL CONTINUOUS REINFORCEMENT (#5 AND SMALLER) 40 BAR DIAMETERS OR 2'-0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTIN6 INTERSECTI0145. LAP CORNER BARS (#5 AND SMALLER) 40 BAR DIAMETERS OR 2'-0" MINIMUM. LAPS OF LARGER BARS SHALL BE MADE IN ACCORDANCE WITH AGI 318-08, CLASS B. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 12" AT SIDES AND ENDS. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS OTHERWISE NOTED ON THE DRAWIN65 OR APPROVED BY THE STRUCTURAL ENGINEER. 20. CONCRETE PROTECTION (COYER) FOR REIN=ORGIN6 STEEL SHALL BE AS FOLLOWS: FOOTIN65 AND OTHER UNFORMED SURFACES CAST A6AINST AND PERMANENTLY EXPOSED TO EARTH 3" SLAB-ON-6RADE BOTTOM REINFORGIN6 (WITH VAPOR BARRIER BELOW) 1 1/2' 21. BONDIN6 A6ENT SHALL BE "CONGRESIVE LIQUID LPL" BY CHEMREX, INC. OR EQUIVALENT, AND SHALL BE USED WHERE NEW CONCRETE I5 PLACED AGAINST PREVIOUSLY PLACED OR EXISTING CONCRETE. PLACE IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, INGLUDIN6 PREPARATION OF EXISTING SURFACES. 22. NON -SHRINK 6ROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL BE MIXED AND PLACED IN STRIGT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 6ROUT STREN6TH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH IT I5 PLACED (6,000 PSI MINIMUM). DECEX I D 114 SHEET INDEX: 51.1 6ENERAL STRUCTURAL NOTES 51.2 GENERAL STRUCTURAL NOTES 52.1 FOUNDATION PLAN 52.2 MEZZANINE FRAMING PLAN 53.1 TYPICAL CONCRETE DETAILS REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWI ,j APR 1 0 2013 PERMIT CENTER DS DAA Architecture + Construction Management 2249 80th Avenue SE Mercer Island, WA 98040 206.617.9010 COUGHLIN PORTER LUNDEEN 413 PINE STREET - SUITE 300 SEATTLE, WA 98101 P: 206/343-0460 F: 206/343-569 I A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION 1/2/13 EMD Permit Submittal Note Date Author Description Stamp Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: GENERAL STRUCTURAL NOTES Scale: N.T.S. Drawn by: JZB Date: 1/2/13 Checked by: EMD Job Number: S-122050-01 Sheet Number: S1.1 General Structural Notes (THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE DRAWINGS) STEEL: 23. STRUCTURAL STEEL DE5I6N, FABRICATION, AND ERECTION SHALL BE BASED ON THE LATEST EDITIONS OF THE A.I.5.G. SPECIFICATIONS AND CODES: 1. SPECIFICATION FOR STRUCTURAL STEEL BUILDIN65-ALLOWABLE STRESS AND PLASTIC DE5I6N, OR LOAD AND RESISTANCE FACTOR DE5I6N SPECIFICATION FOR STRUCTURAL STEEL BUILDIN65. 2. CODE OF STANDARD PRACTICE FOR STEEL BUILDIN65 AND BRID6E5, ADOPTED MARCH 18, 2005. IN INCE TO SECTIONS 3.1.2 AND 4.4.1, THE CONTRACT DOCUMENTS (DESI6N DRAWIN65) SHOW COMPLETE CONNECTION DETAILS FOR ALL MEMBERS EXCEPT THOSE NOTED TO BE DESIGN -BUILD ITEMS. ALTERNATE CONNECTION DETAILS REQUESTED BY THE FABRICATOR SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL VIA A REQUEST FOR INFORMATION (RFI) PRIOR TO COMPLETION OF SHOP DRAWIN65. IN REFERENCE TO SECTION 3.1.6, FABRICATOR SHALL ALSO REVIEW PROJECT SPECIFICATIONS AND ARCHITECTURAL DRAWIN65 TO DETERMINE PAINTIN6 AND GALVANIZING REQUIREMENTS. MEMBERS EMBEDDED IN CONCRETE, MASONRY OR TO RECEIVE SPRAY -0N FIREPROOFIN6 SHALL NOT BE PAINTED. DO NOT PAINT OR 6ALVANIZE AREAS OF PIECES TO BE FIELD WELDED, OR REMOVE PAINT AND 6ALVANIZIN6 IN FIELD PRIOR TO WELDIN6. IN INCE TO SECTION 3.3, IN THE EVENT OF DISCREPANCIES BETWEEN DESIGN DRAWINGS AND SPECIFICATIONS, THE DESIGN DRAWIN65 60VERN. IN REFERENCE TO SECTION 4.1, THE FABRICATOR SHALL NOT ASSUME BID PAGKA6E5 CONSTITUTE RELEASIN6 THE DRAWIN65 FOR CONSTRUCTION WITHOUT EXPLICIT DIRECTION TO DO 50 BY THE OWNER. 3. SPECIFICATION FOR STRUCTURAL JOINTS USIN6 ASTM A325 OR A410 BOLTS. CONTRACTOR SHALL ALSO COMPLY WITH OSHA RE6ULATION 21 CFR PART 1126 SUBPART R - STEEL ERECTION, PUBLISHED JANUARY 16, 2001. MISCELLANEOUS PLATES FOR 6UYIN6 GABLE ATTACHMENTS, TEMPORARY JOIST BRACING, ETC. SHALL BE ADDED AS REQUIRED. CONTRACTOR SHALL EVALUATE COLUMNS AND PROVIDE ADEQUATE BASE PLATE SHIMS, 6UYS, OR TEMPORARY BRACIN6 A5 REQUIRED PER SECTION 1126.155. 24. STRUCTURAL STEEL, INCLUDIN6 PLATES, ANGLES, CHANNELS, AND RODS, SHALL CONFORM TO ASTM A36, Fy = 3b K5I. STEEL PIPE SHALL CONFORM TO ASTM A53, TYPE E OR 5, 6RADE B, Fy = 35 K5I. STRUCTURAL TUBING (HSS) SHALL CONFORM TO ASTM A500, GRADE B, Fy = 46 K5I. ANCHOR BOLTS AND CONNECTION BOLTS SHALL CONFORM TO ASTM A301. 25. DIMENSIONAL TOLERANCE FOR STRUCTURAL STEEL MEMBERS SHALL BE PER THE AISG CODE OF STANDARD PRACTICE FOR STEEL BUILDIN65 AND BRID6E5, SECTION 6.4 AND ASTM SPECIFICATION A6. UNLESS SPECIFICALLY ALLOWED BY THE EN6INEER, COLUMN MEMBERS SHALL NOT BE MODIFIED BY THE ROTARY STRAI6HTENIN6 PROCESS. 26. HOLE SIZES IN STEEL MEMBERS FOR CONNECTIONS TO CONCRETE SHALL BE A5 FOLLOWS UNLESS SPECIFIED OTHERWISE ON THE DRAWIN65: ANCHOR TYPE CAST-IN-PLAGE ANCHOR BOLTS MAXIMUM HOLE DIA. OVER NOMINAL BOLT DIA. OTHER THAN COL. BASE PLATES COL. BASE PLATES 1/16" * TABLE 14-2 OF AISC STEEL CONSTR. MANUAL, 13TH ED. * USE OF LAR6ER HOLES WOULD REQUIRE THE USE OF WELDED PLATE WASHERS AND WOULD REQUIRE PRIOR APPROVAL BY THE STRUCTURAL ENGINEER. HARDENED OR COMMON PLATE WASHERS ARE REQUIRED BELOW ALL NUTS WHERE OVERSIZED HOLES ARE USED AND SHALL BE SIZED TO COVER ENTIRE HOLE. MINIMUM WASHER SIZES FOR COLUMN BASE PLATES SHALL BE IN ACCORDANCE WITH TABLE 14-2 OF THE AISG STEEL CONSTRUCTION MANUAL, 13TH EDITION. 21. ALL WELDING SHALL BE IN CONFORMANCE WITH A.I.5.G. AND A.W.S. STANDARDS AND SHALL BE PERFORMED BY W.A.B.0. CERTIFIED WELDERS U5IN6 E10XX ELECTRODES. ONLY PREQUALIFIED WELDS (A5 DEFINED BY A.W.S.) SHALL BE USED. DO NOT PAINT OR 6ALVANIZE AREAS OF PIECES TO BE FIELD WELDED, OR REMOVE PAINT AND 6ALVANIZIN6 IN FIELD PRIOR TO Y'ELDIN6. THE WELD SYMBOLS SHOWN ON THE DRAWIN65 ARE INTENDED ONLY TO AIDE THE CONTRACTOR IN THE DETERMINATION OF FIELD VERSUS SHOP WELDIN6. THE CONTRACTOR SHALL WORK WITH THE FABRICATOR AND ERECTOR TO COORDINATE THE FINAL DETERMINATION OF FIELD VERSUS SHOP HELPS TO ACCOMMODATE THE CONSTRUCTION SEQUENCIN6 OF THE PROJECT. ALL WELDS SHALL BE MADE WITH A FILLER WELD METAL THAT HAS A MINIMUM GHARPY V -NOTCH TOU6HNE55 OF 20 FT. -LBS. AT 0 DEGREES F, A5 DETERMINED BY AH5 CLASSIFICATION OR MANUFACTURER CERTIFICATION. PROPOSED FILLER MATERIAL FOR BOTH SHOP AND FIELD WELDS SHALL BE SUBMITTED FOR REVIEW PRIOR TO CONSTRUCTION. 26. COLD -FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE, AND 6A6E SHOWN ON THE DRAWIN65. NOTATIONS ON THE DRAWIN65, RELATING TO MEMBER TYPES AND SIZES OR MISCELLANEOUS FRAMIN6 ITEMS, REFER TO CATALOG NUMBERS OF THE "STEEL STUD MANUFACTURER'S ASSOCIATION" STANDARD SPECIFICATIONS, AND ICG -ES REPORT N0. 4143. ALTERNATE FRAMIN6 SHALL BE SUBJECT TO REVIEW BY THE ARCHITECT AND STRUCTURAL EN6INEER PRIOR TO FABRICATION. ALL GOLD -FORMED STEEL FRAMIN6 SHALL ALSO CONFORM TO THE A.I.5.I. "SPECIFICATION FOR THE DE5I6N OF GOLD -FORMED STEEL STRUCTURAL MEMBERS." 21. THREADED STUDS (CPL'S OR GFL'5) FOR CONNECTION OF STRUCTURAL STEEL TO OTHER ELEMENTS SHALL BE MANUFACTURED FROM MATERIAL CONFORMI146 TO ASTM A106 6R. 1010 THROUGH 1020 (TYPE 2, Fu = 60 KSI MIN.). HEADED STUDS SHALL BE WELDED IN CONFORMANCE WITH THE REQUIREMENTS OF A.W.5 CHAPTER 1. UNLESS OTHERWISE NOTED, 5TUD5 SHALL BE WELDED BY THE AUTOMATIC MACHINE WELDIN6 PROCESS IN CONFORMANCE WITH A.W.S. REQUIREMENTS. STUD TYPES SHALL BE MANUFACTURED BY NELSON STUD WELDIN6, INC. OR EQUIVALENT. HEADED STUDS SHALL BE TYPE 53L SHEAR CONNECTORS, THREADED STUDS SHALL BE TYPE CPL PARTIALLY THREADED STUDS OR TYPE CFL FULLY THREADED STUDS. WOOD: 30. FRAMING LUMBER SHALL BE KILN DRIED OR MG -11, AND 6RADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD 6RADIN6 RULES FOR NEST COAST LUMBER NO. 11. FURNISH TO THE FOLLOWIN6 MINIMUM STANDARDS: STUDS, PLATES, LED6ER5 4 MISCELLANEOUS LI6HT FRAMIN6: HEM -FIR NO. 3 OR STUD GRADE MINIMUM BASIC DE5I6N STRESS, Fb = 500 P5I, E = 1200 K5I Fc = 125 P5I , Ft = 300 PSI 31. EN6INCCRCD WOOD I -JOISTS SHALL BE FURNISHED AND INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL NECESSARY BRID6IN6, BLOGKIN6, BLOCKING PANELS, STIFFENERS, ETC., SHALL BE DETAILED AND FURNISHED BY THE MANUFACTURER. PERMANENT AND TEMPORARY BRID6IN6 SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURER'S INSTRUCTIONS. ALL JOIST HAN6ERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH ENGINEERED WOOD I -JOISTS PROVIDED. DE5I6N SHOWN ON THE DRAWIN65 I5 BASED ON JOISTS MANUFACTURED BY REDBUILT LLC IN ACCORDANCE WITH ICG -ES REPORT NO. ESR -2114. ALTERNATE ENGINEERED WOOD I -JOISTS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND STRUCTURAL EN6INEER. A CURRENT NER OR ICC -ES REPORT AND A LIST STATIN6 THE ITEM -FOR -ITEM SUBSTITUTION MUST BE SUBMITTED TO THE STRUCTURAL EN6INEER FOR ANY PROPOSED SUBSTITUTES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EN6INEERIN6 COSTS RELATIN6 TO REVIEW AND/OR RE-DESI6N TO ACCOMMODATE PROPOSED SUBSTITUTIONS. DE5I6N LOADS SHALL BE A5 FOLLOWS, UNLESS OTHERWISE NOTED: LIVE LOAD PER DESIGN LOADIN6 CRITERIA DEAD LOAD 16 P5F THE JOIST MANUFACTURER SHALL COORDINATE LOCATIONS AND SUPPORT CONFIGURATIONS OF PLUMBIN6, MECHANICAL UNITS, DUCTS, AND/OR OTHER MISCELLANEOUS ITEMS WITH THE CONTRACTOR PRIOR TO JOIST FABRICATION. THE JOIST MANUFACTURER SHALL DE5I6N JOISTS TO SUPPORT ALL LOADS ASSOCIATED WITH SUCH ITEMS. THE JOIST SHOP DRAWIN65 SHALL INCLUDE ALL DESI6N LOADS AND APPROVED HAN6ER CONNECTION DETAILS TO JOISTS FOR SUPPORT OF HUNG MECHANICAL SYSTEM COMPONENTS. SUBMIT SHOP DRAWIN65 AND DE5I6N CALCULATIONS TO THE ARCHITECT AND STRUCTURAL EN6INEER FOR REVIEW PRIOR TO FABRICATION. DESIGN SUBMITTALS SHALL BEAR THE STAMP AND 5I6NATURE OF A REGISTERED PROFESSIONAL ENGINEER, STATE OF WASHIN6TON. ALL I -JOIST HANGERS SHALL BE 'MIT' SERIES, UNLESS OTHERWISE NOTED. 32. FLOOR 4 WALL SHEATHIN6 SHALL BE APA RATED, EXTERIOR OR EXPOSURE 1 PLYWOOD OR ORIENTED STRAND BOARD (056) IN CONFORMANCE WITH IBC SECTION 2303.1.4. SHEATHING SHALL BE MANUFACTURED UNDER THE PROVISIONS OF VOLUNTARY PRODUCT STANDARDS DOC P5 1-01, P5 2-04, OR APA PRP -108 PERFORMANCE STANDARDS AND POLICIES FOR STRUCTURAL USE PANELS. SEE DRAWIN65 FOR THICKNESS, SPAN RATING, AND NAILING REQUIREMENTS. UNLESS OTHERWISE NOTED, WALL SHEATHIN6 SHALL BE 1/2" (NOMINAL) WITH SPAN RATING OF 24/0. 6LUE FLOOR SHEATHIN6 TO ALL SUPPORTING MEMBERS WITH ADHESIVE CONFORMIN6 TO ASTM SPECIFICATION D3416. 33. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STR0N6-TIE" BY SIMPSON COMPANY, A5 SPECIFIED IN THEIR GATAL06 N0. C-2011. ALTERNATE CONNECTORS CONFORMIN6 WITH IBC SECTION 1116 MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE STRUCTURAL EN6INEER. A CURRENT ICC -ES REPORT AND A LIST STATIN6 THE ITEM -FOR -ITEM SUBSTITUTION MUST BE SUBMITTED TO THE STRUCTURAL EN6INEER FOR ANY PROPOSED SUBSTITUTES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EN6INEERIN6 COSTS RELATING TO REVIEW AND/OR RE-0ESI6N TO ACCOMMODATE PROPOSED SUBSTITUTIONS. INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, CENTER STRAP ON JOINT AND INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER, WITH EQUAL NUMBER AND SIZE OF FASTENERS IN EACH MEMBER. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A301. INSTALL WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LA6 SCREWS BEARIN6 ON WOOD. ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME 6RADE (MINIMUM) AS MEMBERS CONNECTED. 34. WOOD FRAMIN6 NOTES: THE FOLLOWING APPLY UNLESS OTHERWISE NOTED ON THE DRAWIN65: A. ALL WOOD FRAMING DETAILS SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE IBC. MINIMUM NAILIN6 SHALL CONFORM TO IBC TABLE 2304.1.1 OR CURRENT IGC -ES REPORT NER-212. COORDINATE THE SIZE AND LOCATION OF ALL OPENIN65 WITH MECHANICAL AND ARCHITECTURAL DRAWIN65. INSTALL WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LA6 SCREWS BEARING ON WOOD. INSTALLATION OF LA6 SCREWS SHALL CONFORM TO 2005 ND5 SECTION 11.1.3, AND INSTALLATION OF BOLTS SHALL CONFORM TO 2005 NDS SECTION 11.1.2. B. FLOOR AND ROOF FRAMING: TOENAIL JOISTS TO SUPPORTS WITH TWO lbd NAILS. ATTACH TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH SIMPSON METAL JOIST HAN6ERS IN ACCORDANCE WITH NOTES ABOVE. FLOOR SHEATHIN6 SHALL BE LAID UP WITH 6RAIN PERPENDICULAR TO SUPPORTS AND NAILED A5 SHOWN ON THE DRAWIN65. INSTALL APPROVED PANEL ED6E CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHIN6 ED6ES. ALL FLOOR SHEATHING ED6E5 SHALL HAVE APPROVED TON6UE -AND - 6ROOVE JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKIN6. ALLOW 1/8" SPAGIN6 AT ALL PANEL ED6E5 AND ENDS OF FLOOR AND ROOF SHEATHI146. TOENAIL BLOCKI146 TO SUPPORTS WITH 16d 0 12"OG. AT BLOCKED FLOOR AND ROOF DIAD, INSTALL FLAT 2x BLOCKIN6 AT ALL UNFRAMED PANEL ED6E5 AND NAIL WITH ED6E NAILING SPECIFIED. G. NAILIN6: MINIMUM NAIL DIAMETER AND LEN6TH SHALL BE AS FOLLOWS: NAIL SIZE ON DRAWIN65 DIAMETER AND LEN6TH SHEATHIN6 NAILS Sd 10d 0.131" x 2 1/4" 0.148" x 2 1/2" EX i RED DEC 14 2,013 REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER DS DAA Architecture + Construction Management 2249 80th Avenue SE Mercer Island, WA 98040 206.617.9010 COUGHLIN PORTER LUNDEEN 413 PINE STREET - SUITE 300 SEATTLE, WA 98101 P: 206/343-0460 F: 206/343-5691 A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION 1/2/13 EMD Note Date Author Permit Submittal Description Stamp Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: GENERAL STRUCTURAL NOTES Scale: N.T.S. Drawn by: JZB Date: 1/2/13 Checked by: EMD Job Number: S-122050-01 Sheet Number: S1.2 �J ,T FOUNDATION PLAN SCALE: 1/4" = PLAN NOTES: I. SLAB -ON -GRADE SHALL BE 6" THICK WITH 414 @ I8"oc EA. WAY AT CENTER, U.D.N. PROVIDE VAPOR BARRIER BELOW SLAB AT INTERIOR SPACES OVER FREE -DRAINING CAPILLARY BREAK MATERIAL TO MATCH EX. CONDITIONS. 2. TOPS OF ALL FOOTINGS SHOWN IN THIS PLAN SHALL BE AT ELEVATION -0'-6", U.O.N. OVER EXCAVATE AND PLACE SUITABLE COMPACTED FILL A5 DIRECTED BY OWNER APPROVED GEOTECHNICAL ENGINEER WHERE REQUIRED. LEGEND: EX. TOP OF SLAB ELEVATION TOP OF FOOTING ELEVATION INFILL SLAB PER PLAN NOTE DEC :14 zoic RFACiEK ED FOR CODE COilliF'I-IANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA, APR 1 0 2013 PERMIT CENTER NOTE: ALL MEMBER SIZES AND DIMENSIONS OF EXISTING STRUCTURE SHOWN ON THE DRAWINGS ARE BASED ON ORIGINAL BUILDING DRAWINGS AND ARE FOR INFORMATION ONLY. CONTRACTOR TO FIELD MEASURE AND VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING ANY WORK. NOTIFY ENGINEER IF CONDITIONS VARY. Architecture + Construction Management 2249 80th Avenue SE Mercer Island, WA 98040 206.617.9010 COUGHLIN PORTER LUNDEEN 413 PINE STREET - SUITE 300 SEATTLE, WA 98101 P: 206/343-0460 F: 206/343-5691 A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION 1/2/13 EMD Permit Submittal Note Date Author Description Stamp Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: FOUNDATION PLAN Scale: As Noted Drawn by: Date: Sheet Number: JZB Checked by: EMD 1/2/13 Job Number: S-122050-01 S2.1 8/53.1 TYP. 1/53.1 3/53.1 FLOOR SHEATHING PER PLAN NOTE I 36I -7t" OPEN H55 8x6x1f6 IIYB" RED 110 ® I6"oc Li H55 8xbx4f6 H55 I4x6x% [10'441 TYP. H55 8x6x5.f6 4/53.1 1176" RED 1010 ® I6"oc 10'-0116" H55 8xbxf6 3/53.1 OPEN 1/53.1 31'-5" 8/53.1 TYP. al' -114" PLAN NOTES: MEZZANINE FRAMING PLAN SCALE: 1/4" = I. FLOOR SHEATHING SHALL BE 3/4" T4G PLYWOOD (PANEL SPAN RATING 48/24). NAIL SHEATHING AT ALL FRAMED PANEL EDGES, DIAPHRAGM BOUNDARIES, STRUTS, BLOCKING, AND SHEAR WALLS BELOW W/ IOd @ b"oc. NAIL SHEATHING AT ALL INTERMEDIATE SUPPORTS 141/10d ® 12"oc. GLUE SHEATHING AT ALL SUPPORTS W/ ADHESIVE CONFORMING TO ASTM SPECIFICATION D3418. 2. TOP OF STEEL BEAM ELEVATION = I0'44", U.O.N. LEGEND': x' -x" TOP OF SHEATHING ELEVATION SPAN DIRECTION OF FRAMING MEMBERS [x' -x"] TOP OF STEEL BEAM ELEVATION DEC :14 203 RE`./IEW'ED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila UILDING DI ISIO11 RECEIVED CITY OF TUKWILA APR 1 0 2013 PERMIT CENTER NOTE: ALL MEMBER SIZES AND DIMENSIONS OF EXISTING STRUCTURE SHOWN ON THE DRAWINGS ARE BASED ON ORIGINAL BUILDING DRAWINGS AND ARE FOR INFORMATION ONLY. CONTRACTOR TO FIELD MEASURE AND VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING ANY WORK. NOTIFY ENGINEER IF CONDITIONS VARY. Architecture + Construction Management 2249 80th Avenue SE Mercer Island, WA 98040 206 . 617 .9010 COUGHLIN PORTER LUNDEEN 413 PINE STREET - SUITE 300 SEATTLE, WA 98101 P: 206/343-0460 F: 206/343-5691 A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION 1/2/13 EMD Permit Submittal Note Date Author Description Stamp Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: MEZZANINE FRAMING PLAN Scale: As Noted Drawn by: JZB Checked by: EMD Date: 1/2/13 Job Number: S-122050-01 Sheet Number: S2.2 1IN 2 H55 ti RAILING PER ARGH'L 3x PLATE RIPPED TO I MATCH FLANGE WIDTH SHEATHING PER PLAN 7 ma i 6 r • J0IST PER PLAN TOP FLANGE JOIST HANGERS PER GENERAL NV %"(1)STRUCTURAL NOTES HSS PER PLAN CPL STUDS @ 32"oc (COUNTERSINK NUTS) 6200 4 FOR CALL-OUTS COMMON SEE DETAIL 4/53.1 6202 3 5 6 irk H55 1 1 —1"-- it. I TRUNCATE AT (3)sides, typ. AT CORNER CONDITION rill 14 NAILER PER 4/53.1 PER PLAN jA / NNW II i ILI T. 34" SHEATHING PER PLAN - EXTEND TO FACE OF WALL I rn' PI 2x BLOCKING IN/ (2) #8 SCREWS TO EX. STUD PLAN H55 PER PLAN PLAN S H55 PER PLAN in 0 JOISTS PER PLAN I a EX. WALL It I/4" GAP _ _ .4 6x4x% (LLH) x 0'-4" H55 PER PLAN —11,-- 6203 7 COLUMN PER PLAN (3)sides, typ. kt r J 41 5500 4 r 8 9 1 . 11 __-,(... 00 El -,-._ 00 I" Ott lit Ex . tit rr.A PER PLAN i/ii PLAN DEC Ili 2013 RSA./iEvvE6 FOR. CODE COMPLIANCE APPROVED APR 3 0 2013 1 City of Tukwila WL. PER PLAN BUILDING DIVISION �4"x V'x1'-O" W/ EX. WALL BASE f (4)4" THREADED RODS WI DBL. HEX NUT AT BOT. 6" SLAB-ON-GRADE INFILL PER PLAN 13 14 • 4 V 16" ISOLATION EX. SLAB-ON-GRADE PLAN JOINT ALL AROUND COL. PER PLAN DOWELS PER 16/53.1 SLAB INFILL PER PLAN ° Al4 • d =_-• wit,/ =__� a EX. SLAB-ON-GRADE PER PLAN 11. 11 y 11 =11= 11 %11,49%.,•, °off .. %" NON-SHRINK —�fli II II = 11 Eci 1= •ti" •.o�:-o•• #5 a tiii,,� 0 -Q x 3'-0" a 12"oc IN c,: ad GROUT EPDXY GROUTED HOLES III = 1=11=11=IItEiIII a C ° 4 d a - • • � II-11—II-11 (4)51DE5 .° PER PLAN , (3)5 ,41i (6)#5 111 � 1=11= = II= EQUALLY AS READ. FOR -11-11 SPACED FOOTING INSTALLATION RECEIVED CITY Or 'rt 1 0 2013 btei` 6201 PERMIT CENTER 1 6 FOOTING PER PLAN AND 16/53.1 EX. FOOTING #5 @ 12"oc IN EPDXY GROUTED HOLES AT ALL LOCATIONS WHEREAPR FOOTING MEETS EX. FOOTING 3500 1 5 DS DAA Architecture + Construction Management 2249 80th Avenue SE Mercer Island, WA 98040 206.617.9010 COUGHLIN PORTER LUNDEEN 4 I 3 PINE STREET - SUITE 300 SEATTLE, WA 98101 P: 206/343-0460 F: 206/343-5691 A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION 1/2/13 EMD Permit Submittal Note Stamp Date Author Description Copyright © 2012 David Sova Project Title: Black Bear Yogurt South Center Square South Building Suite 148 Sheet Title: DETAILS Scale: 3/4"=1'-0" Drawn by: JZB Checked by: EMD Date: 1/2/13 Job Number: S-122050-01 Sheet Number: S3.1