Loading...
HomeMy WebLinkAboutPermit D13-116 - UPS - TENANT IMPROVEMENTUPS 13035 GATEWAY DR EXPIRED 03/02/14 D13-116 City olkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 0004800015 Address: 13035 GATEWAY DR TUKW Suite No: Project Name: UPS DEVELOPMENT PERMIT Permit Number: D13-116 Issue Date: 06/26/2013 Permit Expires On: 12/23/2013 Owner: Name: EPROPERTY TAX INC DEPT #207 Address: PO BOX 4900 , SCOTTSDALE AZ 85261 Contact Person: Name: DAVID KEHLE Address: 1916 BONAIR DR SW , SEATTLE WA 98116 Contractor: Name: PRECISION BUILDERS INC Address: PO BOX 98609 , DES MOINES WA 98198-0609 Contractor License No: PRECIBI151C2 Lender: Name: SELF FUNDED - UPS Address: Phone: 206-433-8997 Phone: 206 878-2948 Expiration Date: 01/19/2014 DESCRIPTION OF WORK: CONSTRUCT NON-BEARING OFFICE PARTITIONS ON FIRST FLOOR & SECOND FLOOR. CREATE SEPARATE FIRST FLOOR OFFICE OPEN AREA, DEMO NON-BEARING WALLS FIRST FLOOR, MODIFY EXISTING CEILING GRID AND LIGHTING Value of Construction: $46,000.00 Fees Collected: $1,485.46 Type of Fire Protection: SPRINKLERS/AFA International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0008 Electrical Service Provided by: SEATTLE CITY LIGHT **continued on next page** doc: IBC -7/10 D13-116 Printed: 06-26-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non -Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: tp,--)-(0,--t 3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: // Date: �‘' Print Name: /Pvl This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. S e PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non -building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D13-116 Printed: 06-26-2013 7: All construction shall be done in conform with the approved plans and the requiremt of the International Building Code or International Residential C International Mechanical Code, Washingto to Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ***FIRE DEPARTMENT CONDITIONS*** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 25: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress doc: IBC -7/10 D13-116 Printed: 06-26-2013 travel. Access to exits shall be marked by r ly visible exit signs in cases where the exit o 'he path of egress travel is not immediately visible to the occ s. Exit sign placement shall be such that no t in an exit access corridor is more than 100 feet (30,480 mm) or he listed viewing distance for the sign, which er is less, from the nearest visible exit sign. (IFC 1011.1) 26: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 27: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1006.1, 1006.2, 1006.3) 28: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 29: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 30: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinlder heads. (IFC 901.4) 31: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 32: All-new sprinlder systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 33: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 34: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 35: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 36: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 37: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 38: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 39: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 40: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 41: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. doc: IBC -7/10 D13-116 Printed: 06-26-2013 CITY OF TUKN*4 Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building PeNo. b -1 1 fa Project No. Date Application Accepted: 4—t,t,0`( Date Application Expires: 10— l L —1 3 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 1/e9 9 Abie Tenant Name:? King Co Assessor's Tax No.: too `f'De • ob1 < Suite Number: IAA Floor: t 2. New Tenant: 0 Yes .. No PROPERTY OWNER Company Name: Name: ��u (a fki,o. Name: G/ 4 �� Address:1(g grub la pew Address: tent/ ablecx2.91Y Address: State: City: *i.t State vi•DZipfl a City: State: Zip: CONTACT PERSON — person receiving all project communication Company Name: Name: ��u (a fki,o. Company Name: 1,14 d Address:1(g grub la pew Address: tent/ ablecx2.91Y City: State: City: *i.t State vi•DZipfl a Zip: (0 Phonew o Fax: X0.433-0 i' •634,1 State: Email: eve* e tirtaiet vote). %1"t Phone: Exp Date: GENERAL CONTRACTOR INFORMATION Company Name: Address: Company Name: 1,14 d Address:1(g grub la pew City: State: Faxidfr6'e-7dq Phone/ .43,,?15a�a,, Zip: Phone: Fax: City: State: Contr Reg No.: Phone: Exp Date: Tukwila Business License No.: H:Wpplications\Forms-Applications On Line\2012 Applicatione\Pennit Application Revised - 2-7.12.docz Revised: February 2012 bh ARCHITECT OF RECORD Company Name: aim & he1imzotirtrel— Architect Name: 0/to otoe Company Name: 1,14 d Address:1(g grub la pew City: tit State: „ Zip: tit `I ie Faxidfr6'e-7dq Phone/ .43,,?15a�a,, Address: Entail:4W* Q ( 1�'j?.Vl{Qarctl, tom " ENGINEER OF RECORD Name: b(' y """ Company Name: 1,14 d Address: Engineer Name: City: State: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: b(' y """ Address: City: State: Zip: gc6t2D Page 1 of 4 1 BUILDING PERMIT INFORMATION -06-431-3670 • Valuation of Project (contractor's bid price): $ 4-(etozo Existing Building Valuation: $ 4. '• )11 (444 Describe the scope of work (please provide detailed information): w e "Id ► ! etfla Rei ON Viorgtew.lietogli pee'+Qi Rts Rotiltet mote tom► ID WN • Wool. �bt�fjF14215r Pine *arc 13%1104 &tut Gwtty ha) tiQiNtt Will there be new rack storage? 0 ....Yes .No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: up GitAkseei Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 14b Compact: Handicap: Will there be a change in use? 0 Yes No If "yes", explain: FIRE PROTECTIONIHAZARDOUS MATERIALS: tgL Sprinklers 141 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 41k 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorms•Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor 8 9"ti 1 . ►io 1 / 4) * \14, ' • IP 2"d Floor _71,4 (8Z(F ( 4, V4 1,. 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: up GitAkseei Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 14b Compact: Handicap: Will there be a change in use? 0 Yes No If "yes", explain: FIRE PROTECTIONIHAZARDOUS MATERIALS: tgL Sprinklers 141 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 41k 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorms•Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: RIZED AGENT: Date: eItcet Print Name: GILD VQ 't Day Telephone: tiro 3' a(1 Mailing Address: Mita , ia W' � u.116. 4s1149 H:WppiicationsWorms-Applications On Line\2012 Applications\Pemut Application Revised - 2-7-12.docx Revised: February 2012 bh City State Zip Page 4 of 4 411 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 0004800015 Address: 13035 GATEWAY DR TUKW Suite No: Applicant: UPS RECEIPT Permit Number: D13-116 Status: APPROVED Applied Date: 04/16/2013 Issue Date: Receipt No.: R13-01987 Initials: WER User ID: 1655 Payment Amount: $902.05 Payment Date: 06/26/2013 01:09 PM Balance: $0.00 Payee: PRECISION BUILDERS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 6711 902.05 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 640.237.114 Total: $902.05 897.55 4.50 Print rI• nR_9R-2n13 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 0004800015 Address: 13035 GATEWAY DR TUKW Suite No: Applicant: UPS RECEIPT Permit Number: D13-116 Status: PENDING Applied Date: 04/16/2013 Issue Date: Receipt No.: R13-01332 Payment Amount: $583.41 Initials: WER Payment Date: 04/16/2013 10:28 AM User ID: 1655 Balance: $902.05 Payee: DAVID KEHLE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 025713 ACCOUNT ITEM LIST: Description 583.41 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 583.41 Total: $583.41 Drinfurl• (ld_1R_9(114 INSPECTION NO. INSPECTION RECORD Retain a copy with permit iii PERMIT NO. CITY OF TUKWILA .BUILDING DII1ISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 431-2451 0 Project: V As 'Type Inspection: Address: 13035 -WA/ Date Called: Special Instructions: Date Wanted i.7 ,,. — of j p.m. Requester: Phone N 7,e - .5 - 1-.530 JApproved per applicable codes. DCorrections required prior to approval. 5 COMMENTS: bK03rI r nspector: Date?) REINSPECTION `"E REQUIED. Prior to next inspection, fee must be'. paid at 6300 South nter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit D13- 11 PERMIT NO. d - CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: )J PS Type of Inspection: 1= frv\ J . Address: 1.,O35 GATE. LOA 11 Date Called: Special Instructions: Date Wanted:'CM- (Q -- al- 2)— 13 (C. �rr „ p.m. Requester: Phone No: &pproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 1 Insp-cto Dat : RE SPECTION FEE REQUIRED. Prig to next inspection. fee must be p -id at 6300 Southcent r Blvd.. Suite 100. Call to schedule reinspection. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting- Summary. 2009 Washington State Energy Ccde Compliance Forms for Nonresidential and Multifamily Residential Project Address UFO Project Info LTG -INT Revised November 2010 Date 04,11477 t*,.)3°! alb Pe. Applicant Name: 141 h1-t1e,b6ti 'fi- 146 Pi2 e r '/irtk,146. lei ILP Applicant Address: itio Applicant Phone: /0(.0 133 -MeV- For Building Department Use P" Project Description Prise en„, 1 New Building ❑ Addition *Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option Q Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive 8. LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed r. Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. m Allowed Lighting Wattage Location (floor plan/room #) Occupancy Description Allowed Watts per ft2 ** Gross Interior Area in ft2 Allowed x Area i " From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts . ,..1,.... -- _o Location (floor plan/room #) o - - ---- v Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed i NEPA 70 - NEC i MAY 2 1 2013 TuI►ila City ®# Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. 7-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable. the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number. and leave Watts/Fixture blank. VElear N5r1140 1.1citti • Rit, get( b i RECEIVED CITY OF TUKWILA APR 1 6 2013 PERMIT CENTER 2009 Washin ton State Ener Code Com.Iiance Form for Nonresidential and Multifamil Residential • . Lighting, .Motor, and Transformer Permit Plans Checklist LTG -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised November 2010 Project Address Date The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2009 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Secti9pse s mponent Information Required Location on Plans Building Department Notes LIgdiiNG\MAttfidie(Section 1313) 1513.1 Local control/access Schedule with type, indicate locations 0"5 1 1513.2 Area controls Maximum limit per switch 1513.3 Daylight zone control Schedule with type and features, indicate locations vertical glazing Indicate vertical glazing on plans overhead glazing Indicate overhead glazing on plans 1513.4 Display/exhib/special Indicate separate controls 1513.5 Exterior shut-off Schedule with type and features, indicate location (a) timer w/backup Indicate location (b) photocell. Indicate location 1513.6 Inter. auto shut-off Indicate location 1513.6.1 (a) occup. sensors Schedule with type and locations 1513.6.2 (b) auto. switches Schedule with type and features (back-up, override capability); Indicate size of zone on plans 1513.7 Hotel/motel controls Indicate location of room master controls •I 1513.8 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) 1514 Max. watts Indicate watts for each exit sign LIGHTING POWER ALLOWANCE (Section 1530-1532) 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture , ... .. ' ' ` `' • 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture. types„' ,ti lamps, ballasts, watts per fixture MOTORS (Section 1511) 1511 Elec motor efficiency MECH-MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERS (Section 1540) 1540 Transformers Indicate size and efficiency J If "no” is circled for any question, provide explanation: 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Project Info Project Address 1; i3o3Oi Elbinio-f AILj 14i Applicant Name: awe ki-ft„6 r® Applicant Address: lei te �i a !j. • 1� �C • � �� py Applicant Phone: UV. 433 _ 9 tj 1 - • [Project Description ❑ New Building ❑ Addition -'Alteration Compliance Option Prescriptive ❑ Component Performance (See Decision Flowchart (over) for qualifications) Occupancy Group ® Nonresidential 0 Multifamily Residential Climate Zone 0 Climate Zone 1 0 Climate Zone 2 ( See Fenestration Area Calculation Total Fenestration Electronic version: these values are automati (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area f 11alllb Semi -Heated Path O yes Allowable if project meets all requirements as defined in section 1310.2 40 ® no calculated separately from other conditioned spaces. Limited to reduce and qualifying thermostat. Envelope Requirements (enter values as applicable) Minimum Insulation R -values Roofs - Insulation Above Deck Roofs - Metal Building REVIFWEU Roofs - Single Rafter _COMPLIANCE NFPA 70 - Roofs - Attic and All Others Walis - Mass Walls - Metal Building MAY 2 1 20 Walls - Steel Framed Walls - Wood Framed and Other _ Floors - Mass L.. City of-Tukvn Floors - Steel Joist SUI DING DIV Floors - Wood Framed and Other Maximum F -factors Slabs -on -Grade - Unheated jj-- Slabs -on -Grade - Heated OH WITH EC 3 SION Envelope Requirements Vertical Fenestration Non -Metal Frame Metal Frame WSE( ally t• Only wall i Entrance Door 1.I10161c Skylights - Without Curb Skylights - With Curb Opaque Doors - Swinging Opaque Doors - Non-Swir Vertical Fenestration Non -North North Skylights Notes: II,Vttbu. Viet/ U Lb fteefaDat OM 10 Lel wthistav 6 il(o RECEIVED CITY OF TUKWILA APR .1 6 2013 PERMIT CENTER .01 ;r) for qualifications) 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Multifamily Residential Climate Zone 2 ( See Electronic version: these values are automati act meets all requirements as defined in section 1310. ately from other conditioned spaces. Limited to reduce iermostat. ENV -SUM Revised December 2010 Date 1/10/2011 For Building Department Use El Change of Use ❑ Seattle EnvStd ❑ Systems Analysis ( continued ) WSEC 302.3 for county'Iist) cally taken from ENV -UA. times 100 equals % Fenestration X 100 = 1. Only allowed as prescriptive path and must be d wall insulation levels. Requires other fuel heating ( continued ) Maximum U -factors . "tis - ;....r•, r. r‘:::'.1 1 i i 'ging -,j %V.t:+1. t : ',I, .Maximum SHGC (or SC) 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Envelope Summary (back) 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Minimum Requirements for Prescriptive Option Use table to determine if project qualifies for the optional Option. All components must meet the stated requireme Climate Zone Climate Zone 1 Cli Occupancy Group Nonresidential Residential, Other than Single -Family Nonresidential Opaque Elements Insulation Min. R -Value Roofs Insulation Entirely above Deck R-30 c.i. R-38 c.i. R-38 c.i. Metal Building R-25 + R-11 Ls R-25 + R-11 Ls R-25 -1- R-11 Ls Single -Rafter R-38 R-38 R-38 Attic and Other R-38 adv or R-49 R-38 adv or R-49 R-38 adv or R -4S Walls, Above grade Mass R-5.7 c.i. I R-11.4 c.i. I R-7.6 c.i. Metal Building R-13 + R-7.5 c.i. R-19 + R-8.5 c.i. R-13 + R-7.5 c.i. Steel Framed R-13 + R-7.5c.i. R-19 + R-8.5 c.i. R-13 + R-7.5 c.i. Wood Framed and Other R-21 R-13 + R- 6 c.i. R-13 + R-7.5 c.i., , R-21 + R-2.5 c.i. Below Grade Wall Same as above grade Sarre Floors Mass R-30 c.i. R-30 c.i. R-30 c.i. Steel Joist R-38 + R-4 c.i. R-38 + R-4 c.i. R-38 + R-4 c.i. Wood Framed and Other R-30 R-30 R-30 Slab -On -Grade Floors Unheated R-10 for 24 in. (with thermal break) R-10 for 24 in. (with thermal break). R-10 for 24 in. (wi thermal break) Heated R-10 c.i.(with thermal break) R-10 c.i. (with thermal break) R-10 c.i. (with then break) Opaque Doors Maximum U -Factor Swinging U-0.600 U-0.400 U-0.600 Non -Swinging U-0.600 U-0.400 U-0.600 Fenestration 0-40% of Wall Assembly Maximum U -factor (NFRC Rate Vertical Fenestration Nonmetal framing U-0.32 U-0.32 U-0.32 Metal framing U-0.40 U-0.40 U -0.4p0 Entrance doors U-0.60 U-0.60 U-0.60 Skylights Without curb (i.e. sloped U-0.50 U-0.50 U-0.50 With curb (i.e. individual unit U-0.60 U-0.60 U-0.60 Fenestration 0-40% of Wall Assembly Maximum SHGC Factor Vertical Fenestration SHGC-0.40 all, OR SHGC-0.45 all PLUS permanent PF > 0.50 on west, south, east No Requirement SHGC-0.40 all, OR SHGC-0.45 all FLU! permanent PF > 0.5C west, south, east Skylights • SHGC-0.35 SHGC-0.35 SHGC-0.35 The following definitions apply: c.i. = continuous insulation, Ls = liner system (see definitions) Footnote 1: Zone 1, nonresidential walls may be ASTM C90 concrete block walls, ungrouted or partially grouted at 32 incl vertically and 48 inches or less on center horizontally, with ungrouted cores filled with material having a maximum thermE in/h•ft2•°F. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily ENV -SUM Revised December 2010 Use table to determine if project qualifies for the optional Prescriptive Option. All components must meet the stated requirement. to Zone 1 Climate Zone 2 Residential, Other than Single -Family Nonresidential Residential, Other than Single -Family Insulation Min. R -Value _ R-38 c.i. R-38 c.i. R-30 c.i. R-25 + R-11 Ls R-25 + R-11 Ls R-25 + R-11 Ls R-38 R-38 R-38 R-38 adv or R-49 R-38 adv or R-49 R-38 adv or R-49 R-11.4 c.i. ' R-7.6 c.i. R-13.3 c.i. R-19 + R-8.5 c.i. R-13 + R-7.5 c.i. R-19 + R-16 c.i. R-19 + R-8.5 c.i. R-13 + R-7.5 c.i. R-19 + R-14 c.i. R-13 + R- 6 c.i. R-13 + R-7.5 c.i., or R-21 + R-2.5 c.i. R-21 + R-5 c.i. above grade Same as above grade R-30 c.i. R-30 c.i. R-30 c.i. R-38 + R-4 c.i. R-38 + R-4 c.i. R-38.0 + R-4 c.i. R-30 R-30 R-30 R-10 for 24 in. (with thermal break). R-10 for 24 in. (with thermal break) R-10 for 24 in. (with thermal break) R-10 c.i. (with thermal break) R-10 c.i. (with thermal break) R-10 c.i. (with thermal break) Maximum U -Factor U-0.400 U-0.600 U-0.400 U-0.400 U-0.600 U-0.400 Assembly Maximum U -factor (NFRC Rated) U-0.32 U-0.32 U-0.32 U-0.40 U -0.4p0 U-0.40 U-0.60 U-0.60 U-0.60 U-0.50 U-0.50 U-0.50 U-0.60 U-0.60 U-0.60 Assembly Maximum SHGC Factor No Requirement SHGC-0.40 all, OR SHGC-0.45 all PLUS permanent PF > 0.50 on west, south, east No Requirement SHGC-0.35 SHGC-0.35 SHGC-0.35 liner system (see definitions) trete block walls, ungrouted or partially grouted at 32 inches or Less on center Luted cores filled with material having a maximum thermal conductivity of 0.44 Btu- 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamil -Buildinq..Permit Plans Checklist • ENV. -CHK 2009 Washington State Energy Code Compliance Forms for Nonreside ial and Multifamily Residential 3030 : t �' Project Address Date b Revitsed December 2010 The following information is necessary to check a building permit application for compliance with the building envelope requirements in th—� Yr;e���i e Washington State Nonresidential Energy Code. Applicability Code (yes,no,na) Section Component Information Required GENERAL REQUIREMENTS (Sections 1301-1314) 1301 (Scope 14/ 1310.2 Location on Plans Building Department Notes Unconditioned spaces identified on plans if allowed Semi -heated spaces Semi -heated spaces identified on plans if allowed 1310.3 1311 1311.1 1311.2 Cold Storage / refrigerat A!I refrigerated spaces identified on plans Insulation ENV-RFG completed. General installation Roof /ceiling insut. 1311.3 Wall insulation 1311.4 1311.5 1311.6 Ilndicate Installation nethod, densities and clearances to achieve 11 intended R -value of all insulation materials Indicate R -value on roof sections for attics and other roofs; Indicate clearances for attic insulation; Indicate baffles if eave vents installed; Indicate face stapling of faced baits Floor insulation Slab -on -grade floor Radiant floor 1312 1312.1 1312.2 1313 Glazing and doors U -factors SHGC & SC Moisture control Indicate R -value and framing material on wall sections; Indicate face stapling of faced baits; Indicate above grade exterior insulation is protected; Indicate mass of masonry walls if mass wall claimed Indicate loose -fill core insulation for masonry wails as necessary Indicate frequency of grouted cores and bond beams as necessary Indicate R -value on floor sections; Indicate substantial contact with surface; Indicate supports not more than 24" o.c.; Indicate that insulation does not block airflow through foundation vents Indicate R -value on wall section or foundation detail; Indicate slab insulation extends down vertically 24" from top; Indicate above grade exterior insulation is protected Indicate R -value on wail section or foundation detail; Indicate slab insulation extends down vertically 36" from the top; Indicate above grade exterior insulation is protected; indicate insulation also under entire slab where req'd. by Official Provide calculation of vertical and overhead glazing area as percent of gross wall area Indicate glazing and door U•factors on glazing and door schedule (provide area -weighted calculations as necessary); Indicate if values are NFRC or default, if default then specify frame type, glazing layers, gapvvidth, low -e coatings, gas filling Indicate glazing solar heat gain coefficient or shading coefficient on glazing schedule (provide area -weighted calculations by orientation as necessary) 1313.1 1313.2 Vapor retarders Roof/ceiling vap.ret. Indicate vapor retarders applied to warm side of insulation 1313.3 Wall vapor retarder Indicate vapor retarder on roof section; or list exception Indicate vap. retard. with sealed seams for non -wood structure Indicate vapor retarder on wall section 1313.4 Floor vapor retarder Indicate vapor retarder on floor section 1313.5 1314 Crawl space vap. ret. Air leakage Indicate required grade ground cover with required overlapping. 1314.1 Bldg. envel. sealing Indicate sealing, caulking, gasketing, and weatherstripping 1314.2 Glazing/door sealing Specify maximum air leakage rates for fenestration and door products 1314.3 Assemb. as ducts Indicate sealing, caulking and gasketing 1314.4 Recessed Lighting Fixtun Indicate IC rating, ASTM E283 cert., and gasketing or caulking to ceiling 1314.5 Loading Dock Seal 1314.6 Continuous Air Barrier PRESCRIPTIVE Indicate weatherseat at cargo and loading dock doors Indicate air barrier sealing on alt roof, wall & floor details Indicate leakage testing method. Provide testing results to building official. Max. leakage of 0.40 cfm/ft2 at 0.3 inch w.g PERFORMANCE (Sections 1320-1323) ENV -SUM Form Completed and attached. 1323 Glazing Indicate number of glazing panes and location of emissivity coating or exception taken COMPONENT PERFORMANCE (Sections 1330-1338) ENV -SUM, ENV -UA, 'Completed and attached. 8 ENV-SHGC Forms If "no" is shown for any question, provide explanation: --- elk Nbia hgeo oreetivoirr litalLervo Cie. Iu Lieu q' voluci ittsuviitv P 6t lo.. NOTICE TO CONTRACTOR CONSTRUCTION CONTRACTOR'S RESPONSIBILITY' Before bidding or starting any construction work, you are required to obtain a written asbestos report from the building owner or owner's agent. The report must be based on a survey by an accredited AHERA building inspector unless the building owner assumes materials in the structure are asbestos or . has other convincing documents showing asbestos is not present in the work area. A building owner may know asbestos has been removed during prior work or that a new building has been constructed using materials certified to be asbestos free. If you discover suspect asbestos materials, you must report them to the building owner within 24 hours. Asbestos materials may be found in enclosed structures or between other materials, where they are not accessible before work. State law specifies a minimum $250 per day fine for failure to obtain the asbestos report. This fine can be applied to both the contractor and building owner. Additional fines may be applied if workers are exposed to airborne asbestos. ' Washington State Department of Labor & Industries regulations & policy with regards to asbestos removal. A Copy of the asbestos report must be made available to the building inspector prior to the first inspection. In addition, if asbestos has been found, confirmation of the completed abatement work must be provided to the building inspector. Inspection scheduling will not be accepted until this documentation is received by the building inspector. 2/3/2014 City of Tukwila Department of Community Development DAVID KEHLE 1916 BONAIR DR SW SEATTLE, WA 98116 RE: Permit No. D13-116 UPS 13035 GATEWAY DR, SUITE 149 Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/2/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/2/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, r Marshall Parmid Technician File No: D13-116 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • 70, d kehled� c h Itect., May 13, 2013 City of Tukwila 6300 Southcenter Blvd. Suite 100 Tukwila, Washington 98188 Attn: Mr. Allen Johannessen Re: UPS 13035 Gateway Drive D13-116 Dear Allen, I am in receipt of your correction letter #1 dated April 26th. The tenant (UPS) has requested that the documents be re arraigned such that it is very clear what work is being done by the UPS contractor with balance done be the Landlord contractor. The sheets have be re done to include just UPS area on the first floor (T2-A-T2C) and the landlord work is T4 -A -T4 -C) The following is in response to your correction letter for the above project: 1. A. Door number El 1 has been revised to be a reversed swinging door B. The north half of the open office 11 has an occupant Toad under 50 so a single exit (E14) is adequate for the exiting. I have altered the path of travel on both sides for a future office layout. The south side of the office has two exits with a noted 36" travel pathway and pathway lighting on the reflected ceiling noted. (T4A-T4-C) 2. Exit pathways are shown on the South side to the two exits and assumed travel pathway locations. These will need to be verified when furniture layout is chosen. Currently this space will be vacant until anew tenant is determined. The North side of the open office is under 50 occupants, so a single exit is allowed. Allen, I trust these answers and revised sheets T1 -A (overall plan), T2 -A -T2 -C, T3-A-T3C, T4 -A - T4 -C and T4 changed to T-5, answer your concerns and you will then be able to issue the permit. Sincerely, CORRF TION LTR# J:.... RECEIVED CITY OF TUKWILA David Kehle MAY 142013 DK/mt PERMIT CENTER Enclosure: 2 sets of Drawings 1)3 1 (206) 433-8997 1916 Bonair Drive S.W. fax (206) 246-8369 Seattle, WA 98116 email: dkehle@dkehlearch.com April 26, 2013 David Kehle 1916 Bonair Dr SW Seattle, WA 98116 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Correction Letter #1 Development Permit Application Number D13-116 UPS — 13035 Gateway Dr Dear Mr. Kehle, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433-7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. File No. DI3-116 W:IPermit Center\Correction Lettersl20/31D13-1 /6 Correction Letter #/.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Project Name: UPS Permit #: D13-116 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. 1. The alteration of the main floor changes the common path of egress travel in the means of egress. Egress plan shows sufficient exits, however one door El 1 shall need to be reversed to open in the direction of egress for exit access. Show the door reversed. Since that hallway to the storage rooms is no longer part of the required egress there would not be any concern for the door opening into that hallway, leaving the wall as is. In addition, if door E 14 is to become a required exit door depending on the length of the common path of travel per the new paths of egress for illumination as described in item #2, that door swing shall also need to be arranged to meet egress. (IBC 1008.1.2) 2. With the alteration of the main floor, egress path illumination is also changed. Specify the proposed, minimum 36 inch wide, paths of egress leading to the exits. This will need to be coordinated with the layout of the open office area #11. These paths are where egress illumination shall be measured at time of inspection for egress lighting. Also dimensions of those paths shall be different than what is shown on the egress plan which shows a straight line to the exits. Where cubicles and office furniture are installed, that straight line would not be a valid exit path to provide emergency illumination. Provide dimensions for those new common paths of egress through the open office area #11. (IBC 1003.6, SECTION 1006, SECTION 1007, SECTION 1016 and 1017.2) Should there be questions concerning the above requirements, contact the Building Division at 206-431-3670. No further comments at this time. • Joanna Spencer From: Todd Reedy Sent: Thursday, April 18, 2013 7:34 AM To: Joanna Spencer Subject: RE: 13035 GATEWAY Dr D13-116 Hi Joanna, All backflow installation and testing is current for 13035 Gateway Dr. Have a nice day, Todd From: Bryan Still Sent: Thursday, April 18, 2013 6:13 AM To: Todd Reedy Subject: FW: 13035 GATEWAY Dr D13-116 From: Joanna Spencer Sent: Wednesday, April 17, 2013 11:44 AM To: Bryan Still Subject: 13035 GATEWAY Dr D13-116 Hi Bryan, Are they current on their backflows ? Thanks. Joanna Phone: (206)431-2440 Fax: (206)431-3665 Joanna.Spencer@TukwilaWa.gov /www.TukwilaWa.gov The City of opportunity, the community of choice. PERMANENT FILE COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-116 DATE: 05-14-13 PROJECT NAME: UPS SITE ADDRESS: 13035 GATEWAY DR Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS. Wit) Building Division lin Public Works ❑ Fire Prevention Structural n Planning Division Permit Coordinator n m DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete tkiIncomplete ❑ DUE DATE: 05-16-13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: Ngr DUE DATE: 06-13-13 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 i PER: T C�D COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-116 PROJECT NAME: UPS SITE ADDRESS: 13035 GATEWAY, DR X Original Plan Submittal Response to Incom lete Letter # g P p DATE: 04-16-13 Response to Correction Letter # Revision # After Permit Issued DEPA' TMENTS: uilding 'ivision �ll N'�'- Lea P`IN.bic Wo s PMn A'('0 `}I t( B'( AUA- Fire Prevention Planning DiGision Structural n Permit Coordinator 1111 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 04-18-13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 21 Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05-16-13 Approved n Approved with Conditions n Not Approved (attach comments) EZ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only ' n CORRECTION LETTER MAILED: Departments issued corrections: Bldg !.1 Fire 0 Ping 0 PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 11411V l Plan Check/Permit Number: D13-116 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: UPS Project Address: Contact Person: 13035 Gateway Dr igegi4 Summary of Revision: Phone Number: —433 vv44-- RECEIVED PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revis. c , Received at the City of Tukwila Permit Center by: lit'Entered in Permits Plus on C:\Users\jennifer-m\Desktop\Revision Submittal Fortn.doc Revised: May 2011 Contractors or Tradespeople Peer Friendly Page • General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name PRECISION BUILDERS INC UBI No. 600553713 Phone 2068782948 Status Active Address Po Box 98609 License No. PRECIBI151C2 Suite/Apt. License Type Construction Contractor City Des Moines Effective Date 2/22/1985 State WA Expiration Date 1/19/2014 Zip 981980609 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WESTC61133M3 WEST COAST BUILDERS INC Construction Contractor General Unused 7/23/1987 6/1/1989 Archived PRECIB*163BR PRECISION BUILDERS Construction Contractor General Unused 1/19/1984 1/19/1986 Archived Business Owner Information Name Role Effective Date Expiration Date SANBURN, SCOT DEAN President 02/22/1985 Amount SANBORN, ELIZABETH ANNE Secretary 12/16/2011 BKW135374707607/15/2012 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 DEVELOPERS INS CO 415171C 01/19/2002 Until Cancelled $12,000.00 01/14/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 20 Ohio Cas Ins Co BKW135374707607/15/2012 07/15/2013 $1,000,000.0007/10/2012 19 Ohio Cas Ins Co BKW125374707607/15/2011 07/15/2012 $1,000,000.0007/07/2011 18 OOHIO CAS INS BL01053747076 07/15/2010 07/15/2011 $1,000,000.0007/13/2010 17 OHIO CABINS CO BL01053747076 07/15/2009 07/15/2010 $1,000,000.00 06/23/2009 16 OOHIO CABINS BL053747076 07/15/2008 07/15/2009 $1,000,000.00 07/11/2008 15 0010 CABINS 53646587 07/15/2007 07/15/2008 $1,000,000.00 07/17/2007 14 PROBUILDERS SPECIALTY INSURANC LAM5005190 07/15/2006 07/15/2007 $1,000,000.0007/14/2006 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period httns://fortress.wa.gov/Ini/bbin/Printasnx 06/26/2013 EXISTING 2 STORY OFFICE SPACE WITH PROSOSED OFFICE REMODEL SEE T-2 AND T-3 EXISTING DOCK ADJACENT TENANT NO WORK OV4r-0"LL BUILDING PLAN Scale: 1 6":EF SEPARATE IRED FOR:R 'i Mechanical .1 Electrical Plumbing Gas Piping City of Tukwila 'tT.. le DIVISION l6' 32' SCALE 1/16" = 11-0" 48' 64' 020 REVISIONS No changes shall be made to the scope cf work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. DAV ORM V MIMS GATEWAY CORPORATE CENTER MM. f[ASAIA6T*rte q0 LEGEND 111.13 0 HO! IAUCA TERMINAL 51tYEEA CWVO fUT�Af t0. � ' • ' �1 16ENN1'3 _ I AREA OF WORK UNDER THIS PERMIT VICINITY MAP kale: NOT TO SCALE EXISTING WALL TO REMAIN EXISTING TO BE REMOVED NEW 3 1/2" METAL STUD WALL At 24" 0.C. 9' WE.IGI-It AS REQUIRED TO BOTTOM OF EXISTING CEILING, 5/8" GYP. BD. ON EACH SIDE >1 NEW DOOR EXISTING DOOR I--� 1' x 8' ExISTINCz 2 -TUBE FLU01� scar T (110 WATTS) N 2' x 4' EXISTING 3 -TUBE FLUORESCENT W/ PARABOLIC LENSE (88 WATTS) 2' x 4' EXISTING 3 -TUBE FLUORESCENT TO BE REMOVED OR RELOCATED (88 WATTS) 2' x 4' RELOCATED 3 -TUBE FLUORESCENT (88 WATTS) 2' x 4' NEW 3 -TUBE t-8 FLUORESCENT W/ PARABOLIC LENSE (88 WATTS) 2' x 4' NEW 2-TU15E FLUORESCENT .ID/ .PARABOLIC LENSE (66 WATTS) E ' EXISTING RESTROOM LIGHT E ILLUMINATED EXIT SIGN 40 DUPLEX OUTLET 120W 4$ POURPLEX OUTLET 120W A WALL TELEPHONE OUTLET, MUDRING, CONDUIT, AND PULL STING ONLY $ ELECTRIC SWITCH BUILDING AND SITE STATISTICS BLDG. CODE : lac 2009 ZONING : C/LI BLDG. TYPE : Y -B SPRINKLERED BLDG. FOOTPRINT : 48033 SF. EXISTING TENANT AREA FIRST FLOOR UPS 1,138 SR FIRST FLOOR VACANT: 6899 SF. WITH 212 SF COMMON AREA SECOND FLOOR UPS: 9,511 SF OCCUPANT :LOAD : B OFFICE UPS FIRST FLOOR: 11 OCCUPANTS SINGLE EXIT UPS SECOND FLOOR: 115 OCCUPANTS TWO EXITS VACANT FIRST: 69 OCCUPANTS, TWO EXITS ENERGY CODES NOTES: I) NO CHANGES TO EXISTING BUILDING ENVELOPE WITH THE EXCEPTION OF FIRST FLOOR EXIT DOOR U-0.60 DEFAULT) 2) LIGHTING EXEMPT - LESS THEN 60% OF FIXTURES ARE NEW AND INSTALLED WATTAGE IS NOT BEING INCREASED CORRECTION LTR#....._.(....... REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 1 2013 City of'�ul�Iwila BUILDING t 'VISION A. FILE COPY Permit No. I �! Plan review approval is subject to errors and omissions. 4Dprovai of construction documents does not authorsza the violation of any adopted code or ordinance. Receipt of approved F : .1. : acknowledged: By Date 6s7 7/ ty Of Twkwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 1 4 2013 PERMIT CENTER MENT FOR: TENANT IMPRO rri F�--I z 0 GATEWAY• CORPORATE VAMIN v P T=1 !`•111nnl imcnfe onrl Ccttlnne‘Ali 1 Iccre1flrel lmantQt('.Ar111 QFt7-1:Qf 1R7(14. -Q\, inslrtrl!c .rAv.ner meeting 05 4A 31T-1.dwa. T-1 5 13/2013 9:55:281PM UJORK IN THIS AREA 16 FOR UPS AND THE CONTRACT UJITH UPS, BALANCE OF AREAS 15 Bl' LANDLORD AND A SEPARATE CONTRACT FOR THE LANDLORD UJORK. ====_-- -EC =_=_ 71 J L. UJORK IN TI -115 AREA 15 FOR UPS AND THE CONTRACT UJITH UPS. BALANCE OF AREAS IS Bi LANDLORD AND A SEPARATE CONTRACT FOR THE LANDLORD UJORK. �OOR PLAN AREAS OF WORK NORTH SCALE: 1/8" = 1'-0" UJORK FOR UP5 15A SEPARATE CONTRACT. UJORK FOR LANDLORD 15 SEPARATE CONTRACT THE SECOND FLOOR UJORK IS UNDER TI -IE CONTRACT WITH UPS REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 1 2013 City of Tukwila BUILDING DIVISION 121 iti RECEIVED CITY or TUKWILA MAY 1 4 2013 PERMIT CENTER m 1 w O 0 DRAWN BY 4 o DESCRIPTION REV PER TENANT F- 0 m 8 c 9 TENANT IMPROVEMENT FOR: UPS GATEWAY CORPORATE CENTER: cu v aS CO M Co d- r --I CO C. o Z WSJ H C''J cp crp U) T1=4, us C:\Documents and Settinas\AII Users\Documents\CAD\1987-198918704-91uos\cd's rev per meetina 05 -14 -13\T -1A T2A-T2B X-1stFloor.dwg, T -1A, 5/13/2013 9:47:31 PM REMOVE EXISTING LIGHTS TO BE RELOCATE REFLECTED CEILING DEMO: UPS NORTH SCALE: 1/8" = 11-0" REMOVE EXISTING GRID AS SHOWN AND LIGHTS TO BE RELOCATED REMOVE 6 2x2 LIGHTS AND 11 2X4 LIGHTS, TO BE RELOCATED COMMON EXET STAIR UPS SCALE: vs° = r -m.• REFERENCE KEY PLAN T-14 REMOVE WALLS FOR NEW DOORS u m4 / 0 ��-FLOOR PLAN DEMO:UPS NORTH SCALE: 1/8" = 11-0" REMOVE EXISTING WALLS AND DOORS AND RE USE DOORS AS ACCEPTABLE REMOVE DOORS FOR NEW IN FILL BY LANDLORD \ N d EXISTING HALLWAY EXISTING STAIR FROM SECOND FLOOR UPS SPACE COMMON HALL AND EXIT STAIR UPS SCALE: 1/8" = 1'-0" REFERENCE KEY PLAN T-14 pEMO NOTES: 1. CAP ANY ELECTRCIAL ABOVE CELING IN J -BOX, MARKED WITH CIRCUIT NUMBER AND PANEL NUMBER 2. REMOVE ANY AND ALL PHONE AND DATA CABELING 3. CAP ANY PLUMBING, WATER ABOVE WITH SHUT -OFFS, WASTE BELOW SLAB. NOTE ON AS BUILT FOR OWNER 4. PRIOR TO DOING ANY DEMOLITION, REVIEW SECOND FLOOR STRUCTURE FOR POST, BEAMS AND BEARINGWALLS AND REPORT TO ARCHITECT. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 1 4 2013 PERMIT CENTER m 0 0 0_ DRAWN BY 4 W 0 ikt w m W 0 DESCRIPTION 1- } 0( N 4 0 4IN 0)00 O� K) 0300 I I le) co 10) Nr 00 z TENANT IMPROVEMENT FOR: W z 0 GATEWAY CORPORATE SUITE 149 z O H C � W irD E-4 o� T2=A uFs C:\Documents and Settings\AII Users\Documents\CAD11987-198918704-9\ups\cd's rev per meeting 05 -14 -13\T -1A T2A-T2B X-1stFloor.dwg, T -2A, 5/13/2013 9:45:02 PM o o O I\ I ❑ 0 0 \I \ i N ,d / o Ir-rc I1- -1- --1-- -›-.1--_JJ 1 o o O 0 O O 11 REFLECTED CEILING DEMO: UPS NORTH SCALE: 1/8" = 11-0" REMOVE EXISTING GRID AS SHOWN AND LIGHTS TO BE RELOCATED REMOVE 6 2x2 LIGHTS AND 11 2X4 LIGHTS, TO BE RELOCATED COMMON EXET STAIR UPS SCALE: vs° = r -m.• REFERENCE KEY PLAN T-14 REMOVE WALLS FOR NEW DOORS u m4 / 0 ��-FLOOR PLAN DEMO:UPS NORTH SCALE: 1/8" = 11-0" REMOVE EXISTING WALLS AND DOORS AND RE USE DOORS AS ACCEPTABLE REMOVE DOORS FOR NEW IN FILL BY LANDLORD \ N d EXISTING HALLWAY EXISTING STAIR FROM SECOND FLOOR UPS SPACE COMMON HALL AND EXIT STAIR UPS SCALE: 1/8" = 1'-0" REFERENCE KEY PLAN T-14 pEMO NOTES: 1. CAP ANY ELECTRCIAL ABOVE CELING IN J -BOX, MARKED WITH CIRCUIT NUMBER AND PANEL NUMBER 2. REMOVE ANY AND ALL PHONE AND DATA CABELING 3. CAP ANY PLUMBING, WATER ABOVE WITH SHUT -OFFS, WASTE BELOW SLAB. NOTE ON AS BUILT FOR OWNER 4. PRIOR TO DOING ANY DEMOLITION, REVIEW SECOND FLOOR STRUCTURE FOR POST, BEAMS AND BEARINGWALLS AND REPORT TO ARCHITECT. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 1 4 2013 PERMIT CENTER m 0 0 0_ DRAWN BY 4 W 0 ikt w m W 0 DESCRIPTION 1- } 0( N 4 0 4IN 0)00 O� K) 0300 I I le) co 10) Nr 00 z TENANT IMPROVEMENT FOR: W z 0 GATEWAY CORPORATE SUITE 149 z O H C � W irD E-4 o� T2=A uFs C:\Documents and Settings\AII Users\Documents\CAD11987-198918704-9\ups\cd's rev per meeting 05 -14 -13\T -1A T2A-T2B X-1stFloor.dwg, T -2A, 5/13/2013 9:45:02 PM RELOCATED EXISTING LIGHTS EXISTING GRID TO REMAIN EXISTING LIGHTS TO REMAIN 0 0 0 0 0 // 0 0 0 D NORTH l 0 0 0 0 c C EFLECTED CEILING NEW: UPS SCALE: I/8 = 1'-0" NOTES: 1. EXISTING LIGHTS ARE BEING RELOCATED AND LESS THAN 65% ARE NEW AND WATTAGE DOES NOT INCREASE 2. LIGHT SWITCHING IN INDUVIDUAL ROOMS WITH MAX. 65% OF 20 AMP CIRCUIT FOUR PLEX STANDARD OUTLET MATCH EXISTING DUPLEX STANDARD OUTLET MATCH EXISTING DATA AND PHONE MUD RING WITH CONDUIT TO ABOVE CEILING (WIRE BY UPSXREFER TO PROJECT MANUAL) m NORTH EFLECTE CEILING NEW BACK HALLWAY: UPS SCALE: 1/8" = 1'-0" m ROOM SCHEDULE: LIPS 1 EXISTING FINISHES TO REMAIN 2-8 FLOOR: EX. CARPET BASE: NEW RUBBER BASE WALL: NEW PAINT (EE) CLG: EX. SUSPENDED ACOUSTIC CEILING 9,15 FLOOR: EX. CARPET BASE: EX. RUBBER BASE AND SKIRT WALL: EX. PAINT NO WORK CLG: EX. SUSPENDED ACOUSTIC CEILING 14 FLOOR: EX. CARPET 13A5E: EX. RUBBER BASE (NEW AT NEW WALLS) WALLS: EX, PAINT (PAINT NEW WALLS) (EE) CLG: EX. SUSPENDED ACOUSTIC CEILING NEW OFFICE 3 84 NEW OFFICE B ;11- 4 I' CD s EX. LOBBY 1 NEW OFFICE 5 8' 1 NEW OFFICE NEW MAIL NEW CLO u A BY /1\Q LANDLORD \NEW 2' DEEP COUNTER TOP ONLY +34" APF PLAM WITH 4" BACKSPLASH (FURN-01) 2 1 W 2' DEEP CABINET PLAN WITH 4" BACKSPLASH (FURN-0I) 2 EX. STAIR 9 NEW WALLS BY LANDLORD NEW WALLS BY LANDLORD EX, ELEVATOR B A NEW WALLS BY LANDLO'' PLAN NE: UPS NORTH SCALE: I/8" = I'-0•• A NEW WALL BY LANDLORD NEW DOOR IN FILL BY LANDLOJ\ EX. HALLWAY 14 EX. SECOND EXIT FROM UPS UPSTAIRS 15 m 4 0 U ELI 0 1 d w a I LU 0 W U w U DESCRIPTION w Q 8 4 N N 1 N In 1 >- 0)M FLOOR PLAN NEW BACK HALLWAY: UPS;; NORTH SCALE: 1/8" = 1'-0" REVIEWED FOR CODECOMPLIANCE R ��® CE APP MAY 21 2013 .� .” City of TukWila BUILDING DIVISION WALL TYPE SCHEDULE :UPS MAR 0 2 2014 A REMOVE EXISTING WINDOW OR DOOR, INFILL WITH STEEL STUDS (3 5/8" X 25 GA AT 24" O.C.), TO MATCH EXISTING CONSTRUCTION, SOUND INSULATED, 5/8" GYP BD EACH SIDE. (BY UPS UNLESS NOTED AS LANDLORD)1\ A\ E3. NEW 3 5/8" STEEL STUDS X 25 GA AT 24" O.C., TO CEILING ABOVE, SOUND INSULATE, 5/8" GYP E3D EACH SIDE( BY UPS UNLESS NOTED 45 LANDLORD) m m DOOR SC1-4EULE: UPSNEW DOORS TO HAVE LEVER HANDLES, DOORS TO MATCH OR RE USE EXISTING EI,E18 EXISTING 3'X7' STOREFRONT INSULATED DOOR E2 -E3 EX. 3'X1' SC WOOD WITH WOOD JAMB 1-5 NEW OR REUSED 3'-0" X T-0" S.C. WOOD DOOR WITH WOOD JAMBS, I I/2 PAIR BUTTS, LOCKSET, WALL STOP, SILENCERS 1 NEW OR REUSED 3'-0"Xi'-0" S.C. WOOD DOOR WITH WOOD JAMB, 1 1/2 PAIR BUTTS, LOCKSET ON CORRIDOR SIDE, FREE EXIT TURN FREELY ON STAIR SIDE, CLOSER, SILENCERS, CARD READER RECEIVED CITY OF TUKWILA MAY 1 4 2013 PERMIT CENTER d N 00 Z 0� ( 0 z 0 z z N E-+ z E-{ UF) C:\Documents and Settings\AII Users\Documents\CAD\1987-1989\8704-9\ups\cd's rev per meeting 05 -1413\T -1A T2A-T2B X-1stFloor.dwg, T-2 B, 5/13/2013 9:45:29 PM 0 _ 0 o NEUJ OFFICE NEW OFFICE ft, EXIT NEIU EXIT SIG '1 00 EX. BBY • • EXI NEW OFFICE— EXISTING PATHWAY LIGHT /\ m NEW OFFICE NEUJ MAIL 1 X. EXIT SIGN IT FROM SECOND T. IT 62' PLUS 60' ON FIRST FLOOR : 122 L UNDER 250 LF ALLWED EXISTING PATHWAY LIGHT /\ RELOCATE EX. EXIT SIGN FROM THERE TO HERE FLOOR PLAN EXIT: UPS NORTH SCALE: I/8" = 1'-0" FOR EXITING IN BALANCE OF SPACE SEE LANDLOORD DRAWING 4C m EXIT FROM SECOND FLOOR UPS,60' PLUS 24' PM FIRST FLOOR : 84 LF (UNDER 250 LF ALLOWED) m E-00 PLAN EXIT 4CK STAIR: LIPS EXISTING EXIT SIGN N \ EX. HALLWAY rn MI MII OM CM MI 1111 IIM IMI MII MI ME CM CM EX. STAIR ' NORTH 1 SCALE: 1/S" = 1'-0" EXITING ON AREAS OUTSIDE THE HALLWAY, ARE SINGLE EXIT COMMON PATHS OF TRAVEL UNDER 100 LF. HALL IS TWO EXITS AND TRAVEL DISTANCE TO OUTSIDE EXITS ON FIRST FLOOR IS UNDER 250 LF. VERIFY LOCATIONS OF EXIT SIGNS AND PATHWAY ILLUMINATION REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 1 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 1 4 2013 PERMIT CENTER 4 Q DRAWN BY c DESCRIPTION z z 0 z w z LU 0- 7 i N et M ) Vt 0) CD CO 0303 149 CO CO OO Z OX i IMPROVEMENT z H Z co v)ft0 0 = �(I) Q Z OJ " El or° Q 124 z CORPORATE v m C:\Documents and Settings\AII Users\Documents\CAD\1987-1989\8704-9\ups\cd's rev per meeting 05 -14 -13\T -1A T2A-T2B X-1stFloor.dwg, T-2 C, 5/13/2013 9:45:44 PM REMOVE EX. 2X4 LIGHTS TO BE RELOCATED (4) x x 0 x 111111111111111111111111 1111111111I111111•11i X i x x REMOVE EXISTING 2X4 LIGHTS TO BE RELOCATED (5) EXISTING GRID AND LIGHTS TO REMAIN. .REFLECTEp CEILING DEMO NORTH SCALE: I/S" : 11-0" REMOVE AND RELOCATED 9 EXISTING LIGHT FIXTURES r LJ REMOVE EXISTING PODUER POLES RELOCATE 24\ A\ REMOVE RETURN END WALL REMOVE EXISTING DOORS AND JAMBS t., FLOOR PLAN DEMO MAR 02201k NORTH SCALE; VS" = 11-0" REMOVED EXISTING DOORS TO BE RE USED IF ACCEPTABLE E pm NOTES: 1. CAP ANY ELECTRICAL ABOVE CELING IN J -BOX, MARKED UUITH CIRCUIT NUMBER AND PANEL NUMBER 2. REMOVE ANY AND ALL PHONE AND DATA CABELIN& 3. CAP ANY PLUMBING, WATER ABOVE WITH SHUT -OFFS, WASTE BELOW SLAB. NOTE ON AS BUILT FOR OWNER REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 1 2013 City of Tukwila BUILDING DIVISION iii RECEIVED CITY OF TUKWILA MAY 1 4 2013 PERMIT CENTER 0 w O d DRAWN BY Q 4 8 b N 0 DESCRIPTION iX 0 0 fa i W Q M i N 9 � O1 4:...........r.. 0000 ix 0 MCO * al._ 44/*N 2 Ce Q 00 Z3`' W r z �O Q =a 166G. t.... ,- to o, IMPROVEMENT z z GATEWAY CORPORATE T3 -A USS RELOCATED LIGHTS ADJUST SPRINKLERS AND MVAC EXISTING GRID TO REMAIN Il /�® EXISTING LIGHTS TO FA REMAIN ctM A I COMPACT FLUORESCENT RECESSED 1=1/ 0 I- 0 0 0 0 0 X X NOTES: RELOCATE EXISTING LIGHT FIXTURES NORTW X X X 11 x X REFLECTED CEILING NEW SCALE: 1/8" = 1'-0" EXISTING LIGHTS ARE BEING RELOCATED AND LESS THAN 65% ARE NEUJ AND WATTAGE DOES NOT INCREASE X X 1 X J ROOM SCHEDULE: EXISTING 31,32 FLOOR:. BASE: UJALLS: CLG: 33 FLOOR: BASE ± WALLS: CLC:: 35 FLOOR: BASE: WALLS: CLG: OFFICES TO REMAIN UN CHANGED EXISTING CARPET NEUJ RUBER BASE NEUJ PAINT (EE) EXISTING SUSPENDED ACOUSTICAL CEILING EXISTING CARPET EX. RUBBER BASE AND SKIRT PAINT EXISTING (EE) EXISTING SUSPENDED CEILING REMOVE EX. CARPET ADD NEUJ VCT NEW RUBBER BASE PAINT ROOM (EE) EX. SUSPENDED CEILING 9i'-11" EX. OFFICE EX. OFFICE EX. OFFICE EX. OPEN OFFICE EX. OFFICE EX. OFFICE EX. OFFICE EX. OFFICE EX. STAIR EX. HALL EX. WOME EX. OFFICE EX. OFFICE EX. ELEVATOR EX. STAIR EX. OPEN OFFICE W 0 DESCRIPTION DRAWN BY SUBMIT FOR PERMIT AND PRICING IW - Q 04-08-13 w m 0 W U H i 4 M i 9 0 0303 re)) 441' N 00 W �a a� 416 SF 6 1/20 = 24 OCC., 1 EXIT EX. OFFICE EX. OFFICE I EX. OFFICE EX. OFFICE EX. OFFICE NEW STORAGE 34 2T-6" REVIEWED FOR E COMPLIANCE APPROVED MAY 21 2013 .��FLOOR PLAN NE NORTH SCALE: I/8" = 1'-0" WALL TYPE SCHEDULE City of Tukwila BUILDING DIVISION E.l NAR 02 201k A REMOVE EXISTING WINDOW OR DOOR, INFILL WITH STEEL STUDS (3 5/8" X 25 GA AT 24" O.C.), TO MATCH EXISTING CONSTRUCTIONS, SOUND INSULATED, 5/S" GYP BD EACH SIDE. B. NEW 3 5/8" STEEL STUDS X 25 GA AT 24" O.C., TO CEILING ABOVE, SOUND INSULATE, 5/8" GYP SD EACH SIDE. DOOR SCHEIDULk�W DOORS TO HAVE LEVER HANDLES, DOORS TO MATCH OR RE USE EXISTING E EXISTING 31X-1' UJOD DOORS NO CHANGES 31,32 NEW OR REUSED 3'-0" X 1-0" SC WOOD DOOR W/ WOOD JAMB,1 1/2 PAIR BUTTS, LOCKSET, WALL STOP, SILENCERS 33 NEW OR REUSED 31-0"X11-0" SC WOOD DOOR WOTH UJOD JAMBS,1 1/2 PAIR BUTTS, LATCHSET, WALL STOP, SILENCERS. 34 NEUJ OR REUSED 2'-6"X1'-0" POCKET DOOR HC WOOD DOOR WITH WOOD JAMB, RECESS PULL, METAL SLIDING DOOR PACKAGE, SILENCERS D 0 BY OTHERS = GENERAL CONTRACTOR DOING UPS WORK NOT LANDLORD WORK DUPLEX STANDARD OUTLET MATCH EXISTING DATA AND PHONE CONDUIT TO ABOVE CEILING WITH PULL STRING (WIRE BY UPSXSEE UPS PROJECT MANAUL) IR/ RECEIVED CITY OF TUKWILA MAY 1 4 2013 PERMIT CENTER U TENANT IMPROVEMENT FOR: GATEWAY CORPORATE CENTER: 73-g USS Q..aa:.....inu AIll 1027_10S201S27(1A_Olunelnrl'e raw nar maafinn nc-1A-131TR0_TSR X_7nr1FInnr Awn T -AR ri/13/2(113 9'48'12 PM 'l- m 91'-11" 10' NEW OFFICE NEUJ OFFICE 0 0 EX. OPEN OFFICE ACCOUNT INC 14 OCC SINGLE EXIT, COMMON PATH = 50 LF EX. OFFICE • • • •` • • • • • REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21 2013 City of Tukwila BUILDING DIVISION EX. OFFICE EX. SREAKROOM NEUJ TRAINING 416 SF 0 1/20 = 24 OCC., 1 EXIT NEW STORAGE 2T-6" 34 EX. MEIN EX. OFFICE EX. OPEN �FICE EX. OFFICE EX. OFFICE 31 OCC SINGLE EXIT, COMMON PATH = '4 LF EX. OFFICE EX. OFFICE EX. WOMEN, EX. OPEN OFFICE EX. OFFICE EX. OFFICE EX. OFFICE FLOOR PLAN NEW: EXITINCz NORTH SCALE: US" = 1'-0" EX. OFFICE EX. OFFICE 1 EX. STAIR EXIT HALL, TU10 EXITS, 115 OCCUPANTS SPLIT AT MIDDLE DISTANCE TO FIRST FLOOR 60 LF TO FIRST FLOOR EAST, 62 LF ON WEST 49 OCC SINGLE EXIT, 24 CONF AND 25 OFFICE, COMMON PATH =15LF EX. OFFICE EX. OFFICE EXITING ON AREAS OUTSIDE THE HALLLU4i', ARE SINGLE EXIT COMMON PATHS OF TRAVEL UNDER 100 LF. HALL 15 TWO EXITS AND TRAVEL DISTANCE TO OUTSIDE EXITS ON FIRST FLOOR IS UNDER 250 LF. RECEIVED CITY OF TUKWILA MAY 1 4 2013 PERMIT CENTER 03CO COp000 MtG N 00 N W to (nO cc0o IY o Z O� CO (Oroo v_4( -UO) TENANT IMPROVEMENT FOR: UPS GATEWAY CORPORATE CENTER: 0 s L Ai T3=C USS C:\Documents and SettinaslAll Users\Documents\CAD\1987-198918704-9\ups\cd's rev per meeting 05-14-131T3A-T3B X-2ndFloor.dwg, T-3 C, 5/13/2013 9:50:29 PM DAVID"N.54 DATE 04-08-13 CHECKED BY own DESCRIPTION SU8t IIT FOR PERMIT AND PRICING REV PER TENANT �1 M Z i B > cn 03CO COp000 MtG N 00 N W to (nO cc0o IY o Z O� CO (Oroo v_4( -UO) TENANT IMPROVEMENT FOR: UPS GATEWAY CORPORATE CENTER: 0 s L Ai T3=C USS C:\Documents and SettinaslAll Users\Documents\CAD\1987-198918704-9\ups\cd's rev per meeting 05-14-131T3A-T3B X-2ndFloor.dwg, T-3 C, 5/13/2013 9:50:29 PM AREA OF WORK FOR UPS (SEE 2,4) REMOVE EXISTING GRID AND LIGHTS BY LANDL01 AVAVAPINII0AMPAIIIIROAL AailL.411 APPAMPAMINInfor 1MOIN -.AL REMOVE EXISTING WALLS, REPAIR GRAD AND FLOOR AND ADJACENT SURFACES m BY LANDLORD 0210:01.014 lila= Illirkilialall.0 -401074.41.0AMMERMISPFA&,141MIL ISI/•ArdrArVr� I s .r1 16.B..‘IZ,.ILZIWIJEM ArArAgriErAwlrolimaimmimmummumm.NaLuibmoi.omw //% //////mwo'ra mplim i m`o'm musimm 1 / AritiMI RSTO i ►�� X711-�®71,x__\fie _ I 111111111111E111111.I .irriIIIITA � �i®`L��M�►�� . ApArom irm / �-eri.s►—11®�11►— , AMMIAMINERM/111111R41111M1111L1M1111M111111 -.... ir.11' APAVAIMMIlrrill101 B11111111A11111111\111MMISIMINE1111111•1111\1111111111MIL 1I!IL' -- APPAVAPAMP101 _�. I \_ T_ --=1—=\= = -r _ - r 1 II�%___ __ pr AlMilir 0 0 1 -11-1\j- 0 Fr 4L;)AVAILO ilikPrfr-TO ir AI Au A IPA% kVA raq m1111 r LI 'MI ism 4iP RIMER �\w n >< REFLECTED GEILINCs DEMO: LANDLORD NORTH SCALE: 1/8" = REMOVE EXISTING GRID AS SHOWN AND LIGHTS TO BE RELOCATED REMOVE 4 2X4 LIGHTS, TO BE RELOCATED AREA OF WORK FOR UPS (SEE 2A) MO EXIS G WA 6 AN pOO , CA EL' TRIC - AB • E CE . NG I -BO ITH ABE rt - /0/_ REMOVE EXISTING WALLS AND DOORS, CAP ELECTRICAL ABOVE CEILING IN J -BOX WITH LABEL BY LANDL01 I FLOOR PLAIN DEMO: LANDLORD NORTH SCALE: 1/S" = 1'-0° REMOVE EXISTING WALLS AND DOORS AND RE USE DOORS AS ACCEPTABLE DEMO NOTES: 1. CAP ANY ELECTRCIAL ABOVE CELING IN J -BOX, MARKED WITH CIRCUIT NUMBER AND PANEL NUMBER 2. REMOVE ANY AND ALL PHONE AND DATA CABELING 3. CAP ANY PLUMBING, WATER ABOVE WITH SHUT -OFFS, WASTE BELOW SLAB. NOTE ON A5 BUILT FOR OWNER 4, PRIOR TO DOING ANY DEMOLITION, REVIEW SECOND FLOOR STRUCTURE FOR POST, BEAMS AND BEARING WALLS AND REPORT TO ARCHITECT, REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 1 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 1 4 2013 PERMIT CENTER w 0 a DRAWN BY Lu 0 Lu 0 DESCRIPTION m 1 w 0 M i 4 1 rq e Ln e 441 O) CO 00 014) coCs1 00 i Cf) 4-1 IMPROVEMENT z z N E—+ z CORPORATE LCD T = LANDLO C:113ncuments and Settinns\AII users\Documents\CAD\1987-198918704-9\uns\cd's rev oer meeting 05 -14 -131T -1A T2A-T2B X-1stFloor.dwa. T -4A (2). 5/13/2013 9:45:58 PM OVAIIPT \ • 0 • IL'. 0. rAIIMIRrew *r.4 NM\ AffivAmwitt metimrAmiP • larAIMEXIM 40,1111 AREA OF WORK FOR UPS (SEE 2A) 21511110,' 'Fora'00i CJI p Aloio A'Awidir-fiT"rA61,-.--144010 E�rro,irt41.11, go, maridor—ArAr. �I mon I1.1ro wrfAidoliiiii NEW GRID AND REPLACE LIGHTS AS SHOWN BY LANDLORR\ h,‘ oo �i�� � i..._. No II am main ice. I .. E.. . 0. . 41.20VAPEW rAllEasii pop Para V ,.. _...,.__ reO o OF. Affratri-Ap &al NOTES: jREFLECTED CEILING NEUJ: L4NLOD NORTH SCALE: 1/e.,,.0. 1. EXISTING LIGHTS ARE BEINGRELOCATED AND LESS THAN 65% ARE NEW AND WATTAGE DOES NOT INCREASE 2. LIGHT SWITCHING IN INDIVIDUAL ROOMS WITH MAX. 65% OF 20 AMP CIRCUIT NEW LIGHTING FIXTURES WITH BATTERY BACK UP FOR PATHWAY LIGHTING NOTE: EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT I5 AT LEAST AN AVERAGE OF I FOOT-CANDLE AND A MINIMUM AT ANY POINT OF 0.1 FOOT-CANDLE MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITED TO DECLINE TO 0.6 FOOT-CANDLE AVERAGE AND A MINIMUM AT ANY POINT OF 006 FOOT-CANDLE AT THE END OF THE EMERGANCY LIGHTING TIME DURATION. A MAXIMUM -TO -MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 51-IALL NOT BE EXCEEDED. AREA OF WJRK FOR UPS (SEE 2A) ROOM SCHEDULE: L4NLO' • je\l, i /1/ idoikk Agra Ir NEW WALLS BY LANDLOR EX. STORAGE 24 EX. STORAGE 25 r 1 z w n, A A BY /`.0 LANDLORD NEW WALLS BY LANDLORD A\ NEW WALLS BY LANDLORD 00 EX. ADA WOMENEO n 0 EX. AD MEN 21 4 O O El EX. TELE 22 • EX. FOR 19 EX. OPEN OFFICE 11 EX. OPEN OFFICE 11 NEW WALLS BY LANDLO-. 0 1. EX. OFFICE 18 EX. OFFICE 12 ■ EX. OFFICE 13 in OA. A X 0 0 EX. OFFICE 11 EX. STAIR 15 EX. OFFICE 16 FLOOR PIAN NEUJ LANDLORD 1 NORTH SCALE: I/8" = I'-0" 11-13 FLOOR: NEW CARPET 16-1S 13A5E: NEW RUBBER WALL: PAINT (EE) CLG:: EX. SUSPENDED ACOUSTIC CEILING ,19 FLOOR: NEW VCT 22-25 BASE: NEW RUBBER BASE WALLS: PAINT (EE) CLG: EX. SUSPENDED ACOUSTIC CEILING 20,21 FLOOR: EXISTING (MODIFY FOR DOOR) BASE: EXISTING (MODIFY FOR DOOR) UJALLS: PAINT ABOVE WAINSCOT (MODIFY FOR DOOR AND REMOVED DOOR) CLG: EX. GYP BD, RE PAINT SGE WALL TYPE SCHEDULE :LANDLORD A REMOVE EXISTING WINDOW OR DOOR, INFILL WITH STEEL STUDS (3 5/8" X 25 GA AT 24" 0.C.), TO MATCH EXISTING CONSTRUCTION, SOUND INSULATED, 5/8" GYP BD EACH SIDE. (BY LANDLORD) AN / B. NEW 3 5/8" STEEL STUDS X 25 GA AT 24" 0.C., TO CEILING ABOVE, SOUND INSULATE, 5/8" GYP BD EACH SIDE.( BY LANDLORD) DOOR SCHEDULE: LANDLO NEW DOORS TO NAVE LEVER HANDLES, DOORS TO MATCH OR RE USE EXISTING E1,E18 EXISTING 3'X7' STOREFRONT INSULATED DOOR E4 -E5 EX. 357' SC WOOD WITH WOOD JAMS ES -E10 E6 EX. 3'X6' SC WOOD WOITH WOOD JAM, E1 PAIR 3'X1' H. MIL DOORS WITH HOLLOW METAL JAMB, INSIDE HANDLE TURNS FREELY FOR EXIT. Ell EXISTING 31X1' SC WOOD WITH WOOD JAMB, REVERSE SWING E12 -E16 EXISTING 3'X1' SC WOOD WITH WOOD JAMB 6 NEW OR REUSED 3'-0"X1'-0" S.C. WOOD DOOR WITH WOOD JAMB, 1 1/2 PAIR BUTTS, PUSH/PULL, CLOSER, KICKPLATES, WALL STOP, SILENCER NEW STOREFRONT, REMOVE EXISTING GLAZING PANEL AND BULKHEAD, INSTALL NEW 3'-0" X1'-0" ALUMINUM STOREFRONT DOOR AND NEW JAMB, WITH INSULATED SAFETY GLAZING, EXIT PADDLE, CLOSER, THRESHOLD, WEATHERSTRIP (U=0.60), MATCH EXISTING STOREFRONT DOOR HARDWARE. (BY LANDLORD) REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 1 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 1 4 2013 PERMIT CENTER w 0 a DRAWN BY 0 m 4:10 Lu w W 0 DESCRIPTION if w Q 0 4 M rel LI) rA•ilinrill.111.1.111.111.1711±,e, 00 CO 01 -- co p• i) Ilh W Z I4 o=1- W_ 4 V) Q 00 z I- J M I—op H 0 F)W 0_ U)0) 00 cirt U U) IMPROVEMENT z z N z 7:4 U CORPORATE IMININOMMIL co • co W � 1 F44 1.1 cri ceD � s E-+ LAND LOf4-3 C:\Documents and Settings\AII Users\Documents\CAD\1987-198918704-91ups\cd's rev per meeting 05 -14 -131T -1A T2A-T2B X-1stFloor.dwg, T-4 B (2), 5/13/2013 9:46:11 PM AREA OF WORK FOR UPS (SEE 2A) EXISTING PATHWAY LIGHT 2 NEW EXIT SIGN MI . i. i. i. IN 1 1 1 1 FL 1 N FI A•4041 �`DEo 000 Mr V,l/1di‘1 ► OMM• \ PAT OF T VEL LF UND 50 4r. CUPA TS iii. -MI MI IN NMN. 1 OP 1 DIAL 1 LF AL ICE A -EA 21 EI3 E TING ATN -Y LIGH 1 1 RELOCATE EX. EXIT SIGN FROM THERE TO HERE \ EXIT FROM SECO • �`� FLOOR, 60' PLUS 2 i� *VI" �� _ ./ f� LF ON FIRST FLOOR 1 J S4 LF UNDER 250 LF ALLOWED EX. STAIR 41111111111111111111111 NEW OPEN OFFICE • EX. STORAGE II d LU EX. AD MEN O O EX. STOR. EX. TELE 11 36" WIDE EXIT PATHWAY TO TWO EXITS, 128 LF WORK IN THIS SPACE IS EY LANDLORD EX. OFFICE EX. OFFICE M1 1 EX. OPFIC FLOOR PLAN NEW EXITINC: L4NLORD NORTH SCALE: 1/8" = 1'-0" 'm'....veAi .... .•i E MAR 0 2 2014 EXITING ON AREAS OUTSIDE THE HALLWAY, ARE SINGLE EXIT COMMON PATHS OF TRAVEL UNDER 100 LF. HALL 16 TWO EXITS AND TRAVEL DISTANCE TO OUTSIDE EXITS ON FIRST FLOOR 15 UNDER 250 LF. VERIFY LOCATIONS OF EXIT SIGNS AND PATHWAY ILLUMINATION VERIFY LOCATION OF 36" EXIT PATHWAY WITH FURNITURE LAYOUT ON NEW TENANT A\ REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21 2013 E) D City of Tukwila BUILDING DIVISION 1)1 IIS RECEIVED CITY OF TUKWILA MAY 1 4 2013 PERMIT CENTER PROJECT 6104-9 DRAWN BY 2524 rEGI TERED DAVID 'ATM' DATE 04-08-13 LCAVID E KERIE CHECKED BY 7'4#T! KEI-ILE - DATE DESCRIPTION SUBMIT FOR PERMIT AND PRICING REV PER TENANT REY PER TENANT REV PER TENANT m M `Il M ‘Q7NOS w 1 N 1St ISI in 03 03 CO (0 N N vv IMPROVEMENT z z W H CORPORATE E-1 T = C LANDLO5R C:\Documents and Sattinns\All 1IsA_rs\flnnllmPnts\CAfl\1QR7_1QRQ1417nd_Q11.nc\nd'c rot/ nor mootinn nV1d1zT_1a T9A_T9R Y_1oHCinnr.1,.fn T_AFI14/9n1 ai •As inn 11 SPACER BAR, OR OTI-4ER SUITABLE SYSTEM, TO KEEP PERIMETER COMPONENTS FROM SPREADING APART. CROSS RUNNER MAIN RUNNER kteMIN. At UN -ATTACHED WALLS MIN. 2" UALL ANGLE NOTE: ATTACH CEILING AND GRID TO WALL ANGLE (MOULDING) AT TWO ADJACENT WALLS VIA POP RIVETS. 4 "12 GA. WIRES WITHIN 2" OF CROSS TEE CONNECTION ARRANGED AT 90° FROM EACH OTHER AND AT AN ANGLE NOT EXCEEDING 45'. LOCATE RESTRAINT PANELS AT 12' O.C. IN EACH DIRECTION AND WITHIN 6' OF EACH WALL. NOTES: NOTE: SUSPENSION WIRES TO BE 12 GAGE AT 4' O.C. W/ ATTACHMENT DEVICES CAPABLE OF SUPPORTING 100 POUNDS. HANGER 4 PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 UNLESS COUNTER SLOPING WIRES ARE PROVIDED 1) MAIN BEAMS TEES AND CROSS TEES MUST BE HEAVY DUTY W/ CONNECTION STRENGTHS OF 100 POUNDS IN COMPRESSION 4 TENSION. 2) CEILING AREAS GREATER THAN 1000 SF MUST NAVE LATERAL FORCE BRACING VIA DIAGONAL SPLAY LURES, LIMITING MOVEMENT TO LESS THAN 1/4" AT POINT OF ATTACHMENT. 3) LIGHT FIXTURES TO BE POSITIVELY ATTACHED TO MAIN AND CROSS TEES. AND IF OVER 56", MUST BE INDEPENDENTLY SUPPORTED. 4) PARTITIONS GREATER THAN 6' TALL NEED INDEPENDENT BRACING VIA SPLAY WIRES (SEPARATE FROM ANY OTHER WIRES). PARTITIONS 6' OR LESS NO ATTACHMENT 15 REQUIRED. 5) SPRINKLE=R HEAD PENETRATIONS MUST HAVE 2" OVERSIZED TRIM TO ALLOW 1" MOVEMENT IN ALL DIRECTIONS. 6) MANUFACTURER CERTIFICATION OF COMPONENT PERFORMANCE AND PERIODIC SPECIAL INSPECTION OF ANCHOR SYSTEM IS REQUIRED. 1) FOR CEILING AREAS EXCEEDING 2500 SF, A SEISMIC SEPERATION JOINT OR FULL HEIGHT WALL PARTITION THAT BREAKS THE CEILING SHALL BE PROVIDED. 8) ALL CROSS TEES SHALL BE CAPABLE OF CARRYING THE DESIGN LOAD WITHOUT EXCEEDING DEFLECTION EQUAL TO Y360 OF ITS SPAN. 9) ALL WIRE TIES ARE TO BE THREE TIGHT TURNS AROUND ITSELF WITHIN 3 INCH. RESTRAINED CEILING DETAILS (MEETS IBC 2009 SEC 808 AND ASTM C 635 ASTM C 636 AND ASCE 1-02) SCALE TYPES REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 1 2013 City of TNk+ BUILDING DIVISION wa02201k PP -D 22" WIDE SOUND BATTS EA. SIDE WALL 8 SOUND WALL FOR WALLS GREATER THAN 8'- 0" IN WIDTH WITHOUT AN INTERSECTING WALL, PROVIDE I2ga. WIRES SPLAYED 9 45° TO AN EYE SCREW ROOF AND TOP OF WALL •uuuu•���•uuui••unr iui•uiiuuuuu r, BLOCK a GRID FOAM TAPE 6 WALL PAINT EXTERIOR FLAT 'BLACK 2 1/2" RUBBER BASE * CARPET we 1 • UJ,4LL SECTION SCALE: 1-1/2" .11-0" CONT. METAL TRIM. 5/8" GYP. BD. (TYPE 'X' ® FIRE RATED WALLS.) ACOUSTICAL BLANKET 6 SOUND WALL. CAULK L SOUNBD. AND ISL. FLOOR WALLS UJOOD FRAME DETAIL SCALE: 1-1/2" .11-0" TYPICAL STUD WALL GLAZING TAPE STANDARD WOOD STOPS SECTION 3 1/2" MTL STUD 2x WOOD BLOCKING 11/2" x OAK JAMB (20 MIN. RATING) 5/8" x OAK STOP SMOKE SEAL SOLID CORE WOOD DOOR W/ OAK VENEER (20 MIN. RATING) 5/8" GYP SD. EACH SIDE (TYPE 'X' RATED a CORRIDOR) 2'-0" OR PER PLAN 1/4" LAMINATED OR TEMPERED SAFTEY GLAZING NOTE FOR RATED CORRIDORS: 1/4" WIRE GLASS IN STEEL GLAZING CLIPS 0 2'-0" O/C OAK FRAME REL ITE/DOOR SCALE: 1-1/2" _ 1'-0" SECTION SECTION RECEIVED CITY OF TUKWILA MAY 1 4 2013 PERMIT CENTER PROJECT 81O4-9 DRAWN BY 2524 ' REGISTERED DAVID "''ITECT DATE ` 04-08-13 DAVID . H' E CHECKED BY STs W ; MHG tib DATE DESCRIPTION SUBMIT FOR PERMIT AND PRICING 0 61 Q M >- cn 47! M(no r;� N g Z �, U) Q Q O O Z�`_ W H cO F- O X r -Q CO CO a 0 z z z T C:\Documents and Settings\AII Users\Documents\CAD\1987-1989\8704-9\ups\cd's rev per meeting 05-14-13\T-5.dwg, T-5, 5/13/2013 9:43:42 PM