Loading...
HomeMy WebLinkAboutPermit D13-122 - CACHE - TENANT IMPROVEMENTCACHE 221 SO UTH CENTER MALL D13-122 City olkukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 221 SOUTHCENTER MALL TUKW Suite No: Project Name: CACHE Permit Number: D13-122 Issue Date: 05/28/2013 Permit Expires On: 11/24/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: MARGO KOZICH Address: 2136 FURCELL DR , FERNANDINA FL 32034 Contractor: Name: PWI CONSTRUCTION INC Address: 155 WEST MAIN ST , MESA AZ 85201 Contractor License No: PWICOCI976MC Lender: Name: TENANT - CACHE WOMEN'S STORE Address: Phone: 904 491-6314 Phone: 480-461-0777 Expiration Date: 12/11/2013 DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENT Value of Construction: $75,000.00 Fees Collected: $2,009.09 Type of Fire Protection: SPRINKLERS/AFA International Building Code Edition: 2009 Type of Construction: IIB Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY **continued on next page** doc: IBC -7/10 D13-122 Printed: 05-28-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: N Number: 0 Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non -Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: L)A Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. r\ Signature: Date: 2.e MAI 25X3 Print Name: (MA 0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: New suspended ceiling grid and light fixture installations shall meet the non -building structures seismic design requirements of ASCE 7. doc: IBC -7/10 D13-122 Printed: 05-28-2013 7: All construction shall be done in conform with the approved plans and the requireme of the International Building Code or International Residential C International Mechanical Code, Washingto to Energy Code. 8: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavation;. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: All racl: storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculation; for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 15: ***FIRE DEPARTMENT CONDITIONS*** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection lag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC doc: IBC -7/10 D13-122 Printed: 05-28-2013 1008.1.8.1) 25: Exit hardware and marking shall meet trequirements of the International Fire Code. Chapter 10) 26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1006.1, 1006.2, 1006.3) 29: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 31: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 34: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2328. (ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 35: Local U.L. central station supervision is required. (City Ordinance #2328) 36: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 37: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 38: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 39: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 40: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 41: Post address on storefront per approved Westfield standards. 42: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 43: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of doc: IBC -7/10 D13-122 Printed: 05-28-2013 such condition or violation. 44: These plans were reviewed by Inspector 511. If you have any questions, please call Thkwila Fire Prevention Bureau at (206)575-4407. doc: IBC -7/10 D13-122 Printed: 05-28-2013 1. CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No: - Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE' LOCATION Site Address: /-Southcenter King Co Assessor's Tax No.: 12/01.0 1L, t —CO 6 Tenant Name: Cache Suite Number: 640 PROPERTY OWNER Name: Cache do CPG Margo Kozich Name: Southcenter Mall Westfield City: Fernandina State: FL Zip: 32034 Address: 835 Market Street Email: margok@commercialpermitgroup.com City: San Francisco State: ca Zip: 94103 CONTACT PERSON - person receiving all project communication Name: Cache do CPG Margo Kozich Address: 2136 Purcell Drive City: Fernandina State: FL Zip: 32034 Phone: (904) 491-6314 Fax: (904) 491-0397 Email: margok@commercialpermitgroup.com GENERAL CONTRACTOR INFORMATION Company Name: tbd Architect Name: Cortland Morgan Address: 711 N fiedler rd City: Arlington State: tx Zip: 76012 Address: Email: Engineer Name: City: State: Zip: Phone: Fax: City: Contr Reg No.: Exp Date: Phone: Tukwila Business License No.: Email: H:\Applications\Forms-Applications On Line\201 I Applications\Pormit Application Revised - 8-9-I I.docx Revised: August 2011 bh New Tenant: Floor: 1 0 Yes ..No ARCHITECT OF RECORD Company Name: Cortland Morgan Architect Name: Cortland Morgan Address: 711 N fiedler rd City: Arlington State: tx Zip: 76012 Phone: (817) 635-5696 Fax: (817) 635-5699 Email: ENGINEER OF RECORD Name: Address: City: State: Zip: Company Name: Engineer Name: Address: • City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUEDe(required for prolects$5,000"or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING- PERMIT INFORMATIO1 — 206-431-3670 Valuation of Project (contractor's bid price): $ U I'5^ ow' Existing Building Valuation: $ Describe the scope of work (please provide detailed information): interior tenant improvement Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in. Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: [f Sprinklers Automatic Fire Alarm one 0 Other (specify) , ,( Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes r No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System – For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Ap,lications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9.1 I.docx Revised: August2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of : . - Construction per; IBC • , Type of Occupancy per IBC' 15t Floor 65( e a t T 3 n U r 0 'S 2nFloor 3'' Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covrred`iDeck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: [f Sprinklers Automatic Fire Alarm one 0 Other (specify) , ,( Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes r No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System – For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Ap,lications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9.1 I.docx Revised: August2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUI LDIN f ' , a ' AGENT: A Signature: Date: "5--.04,---1,4 Y-/�rlG1 /— Day Telephone: -/ �J Print Name: / 77/ '7C TOO Mailing Address: City State Zip H:\P.pplications\Forns-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 4 of 4 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D13-122 Address: 221 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/18/2013 Applicant: CACHE Issue Date: Receipt No.: R13-01738 Initials: WER User ID: 1655 Payment Amount: $1,219.40 Payment Date: 05/28/2013 10:51 AM Balance: $0.00 Payee: PWI TRANSACTION LIST: Type Method Descriptio Amount Payment Check 52114 1,219.40 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 640.237.114 Total: $1,219.40 1,214.90 4.50 Printpri• n5 -9R-91)11 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D13-122 Address: 221 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 04/18/2013 Applicant: CACHE Issue Date: 05/28/2013 Receipt No.: R13-01984 Payment Amount: $63.00 Initials: WER Payment Date: 06/26/2013 10:58 AM User ID: 1655 Balance: $0.00 Payee: ADAM MANGOLD TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 195168 ACCOUNT ITEM LIST: Description 63.00 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 63.00 Total: $63.00 Prin+Pd• nR-9R-9n1� Ciq- of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www. ci. tukwila. wa. us SET RECEIPT Copy Reprinted on 04-18-2013 at 12:17:40 04/18/2013 RECEIPT NO: R13-01356 Initials: JEM User ID: 1165 Payee: COMMERCIAL PERMIT GROUP, INC. Payment Date: 04/18/2013 Total Payment: 926.30 SET ID: S000001964 SET NAME: CACHE SET TRANSACTIONS: Set Member Amount D13-122 789.69 EL13-0361 87.63 M13-070 48.98 TOTAL: TRANSACTION LIST: Type Method Description Amount Payment Check 3549 926.30 TOTAL: 926.30 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 87.63 838.67 TOTAL: 926.30 D/3-12-2_ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: , t VW na�EJ*C. Tye of Inspection: )) t �.d Ca . t...,_ . co! `-( 1k A72 SC M .f I h- Date Called: Special Instructions: ��qk` & —Ot Date Wanted: /,---5:,_ _m. ? -ZZ- 13 Requester: Phone No: (pj Z- 3rr2-3r7I/ Approved per applicable codes. ['Corrections required prior to approval. COMMENTS: I EM4RG 04(iC/ - 1.../1 /1/1^/ C - APPia/C-�(-1) al C.,A.4Z - A.PP>'a/e c1 Pe (,„, ,--k- 0 ,t to le. -1.4, (#-.4 n Date: 7--22-15 EINSPECTION FEE REQUI ' ED. Prior to n t inspection, fee must be ai at 6300 Southcenter Blvd.. Suite 100. Cat to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 .b13 -122.. - Project: 0 AQ 14F Type of Inspection: e M P}- Y c/ I10- ( ti �. Address: ,oI SC' 01faII Date Called: �1v,) c.7 i 0e..E s,lac Special Instructions: 00 02 Date Wanted: a.m. 7 -- I /s - 5 �,., nl j -(±1;, Requester: ...._, Phone No: QApproved per applicable codes. DCorrections required prior to approval. COMMENTS:(.2) . ci,M(\ A t-eOevAr30 .`rn 6Y17- �1v,) c.7 i 0e..E s,lac 6 00 02 r)S ) -,c�a 0,„ J p 6w G_,,,,;_i 5 �,., nl j -(±1;, < ...._, tnsspe`ctof Date: 7-i8-13 —1(‘EINSPECTION FEE RE UIRED. Prior to next inspection, fee must be paid at 6300 SouthcenteriBlvd., Suite 100. Call to schedule reinspection. .i1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 ta-1' Project: C1AcHE . Type of Inspection: mus -1j bC (-1N( Address: k s MAik Date Called: :. Special Instructions: Date Wanted: aa�r -. Requester: Phone No: (oo2-362 --s7IC.- Approved per applicable codes. El Corrections required prior to approval. COMMENTS: *13--- 1 REINfiPECTION FEE REQLRED. Prior to Next inspection, fee must be paicj�at 6300 Southcenter B d.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project. CI AQ. r+E. Type of Inspection: F2AAA(tJG . Address: 221 cDC tMAlI Date Called: Special Instructions: Date Wanted:. 2-�t�' -- 13 a.m. C m. Requester: Phone No: EyApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspecio:� � \� Date! — C ` 3 pREINSPECTION FEE REQUIRED. Prior to net inspection, fee must be a �d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 I< - 13''22 -- Project l'AQ.ItE.. 0 to,0,0 --\--vvi-v";&,c-Th u\,,,,I?i,N.p--, --7,(,..„-,----( Type of Ipspection: i'etvt\1IQ (O Z.) L ; (( f`f f S pc) ✓ i M :-c ov u,..)7.e-- t?``_' Address: .. 22. 1 Sc 0"41I Date Called: Special Instructions: Date Wanted:. ( -- Z. L_ 1 On p.m. Requester: Phone No: Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: A . 0 to,0,0 --\--vvi-v";&,c-Th u\,,,,I?i,N.p--, --7,(,..„-,----( ,----1-0 e jPr--I ✓ioi 1 t. P( .60,vc) Z.) L ; (( f`f f S pc) ✓ i M :-c ov u,..)7.e-- t?``_' e 6e k i c/%�/, cCo L (L.- Us -C/1/4/ ,} i Inspe tor: Date: R INSPECTION FEE REQUIRED. Prior to next inspection, fee must be p id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431.2451 ProjectTyp /I-6._ rt of Inspection: e._. 'r 2.. - l.� A S ( , Address: 2:2- 1 SC. A44-1(_ Date Called: _ Special Instructions: Date Wanted: �? � 13 -- c..a.mp.m... �j "tet Requester: Phone �0 2- -gin .-37 (SO ElApproved per applicable codes. '.Corrections required prior to approval. .,, COMMENTS: r4-.)-) l I jj. ✓- . 3,9fWe._1 4soct4 t_S /2- j ?IV -AAA"; ev c ki 11,1,,0 G.A., : 0 vi --?,,,,,.4 A-5 -,,isW*1. / '-... I Spector: f., Dat` ("1' F-7 EINSPECTION FEE REWIRED. Prior next inspection, fee must be p id at 6300 SouthcenteltBlvd.. Suite 10 . Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /3-S_. /3& PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: C-� -ro. n,, ,,,. L_ Type ofI spection: 5 P F cc__ c vv 0-6.- Contact Person: Address: a. ( S Suite #: Special Instructions: Permits: Occupancy Type: Phone No.: pproved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: -7/20 Hrs.: ,-k.-, 5---a--- $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: City: Company Name: State: Zip: Word/Inspection Record Form.Doc T.F.D. Form F.P. 113 i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit �/3-122 l�-F-/3.6 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: / Type of Inspection: / Address: m Suite #: Z21 So4r-hce^dei !'/a11 Contact Person: Phone No.: Special Instructions: 11N Approved per applicable codes. Corrections required prior to approval. COMMENTS: FA 60„„, l - OK Needs Shift Inspection: Sprinklers: f.. - Fire Alarm: Hood & Duct: 4 - Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: iii Fins -ti Date: 7.0/W Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: City: Company Name: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit P/ 3- /).02- i71- 5-- 2Lf3-5- /?� INSPECTION NUMBER CITY OF\TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 PERMIT NUMBERS Project:? � 2. Type o Inspection: 5coves Contact Person: • Address: r /'"14 L t- Suite #: . 71. Special Instructions: Phone No.: Permits: I -Approved per applicable codes. Corrections required prior to approval. COMMENTS: drtt.Cho v-�r Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Irrnspector j%, ,,1 r- Date: 6A(//Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 rii 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential terior Lighting Summary LTG -INT 20013 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address CACHE Date 4/16/2013 SOUTHCENTER MALL SPACE #640 For Building Department Use FILE Copy TUKWILA, WA 98188 Applicant Name: 4 - Fill out this line on PRJ-SUM Applicant Address: 5 - Fill out this line on PRJ-SUM T' Applicant Phone: 6 - Fill out this lwine on PRJ-SUM f , Project Description _ ' New Building Addition Alteration Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option • Prescriptive • Lighting Power Allowance Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ' Ho changes are being made to the lighting and space use not changed Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan/room #) Occupancy Description Allowed Watts per ft2** Gross Interior Area in ft2 Allowed x Area SALES RETAIL 1.33 2051 2728 SALES RETAIL - LIGHTING POWER ALLOWANCE 1.40 190 266 SALES RETAIL - ADDITIONAL LIGHTING POWER ALLOWANCE 1000.00 1 1000 ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 3994 Proposed Lighting Wattage Location (floor plan/room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed SALES TRACK WITH 1 AMP CURRENT LIMITER 1 120 120 SALES TRACK WITH 2 AMP CURRE,.T LI EVIEr /P-p-�F R 1 240 240 SALES TRACK WITH 3 AMP CURRE.�11 LEhTEp�Rpyf"�OMpg� 9�`JNCE 1 360 360 SALES, CHANGE ROOM FIXTURE A AP ED - 19 66 1254 SALES FIXTURE J Pijq Y ���� 10 25 250 SALES FIXTURE D 5 25 125 CHANGE ROOM FIXTURE G 1 56 56 SALES �{,," FIXTURE F(4') o f Te 8 56 448 SALES B R {City 1lj FIXTURE F(3') UILDING DIIO DIVISION y 12 42 504 WORKROOM 3 56 168 FIXTURE H - - Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 3525 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greeter of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. RECEIVED CITY OF TUKWILA APR 1 8 2013 PERMIT CENTER PrHZZ .1•f 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential terior Lighting Summary (back) LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Prescriptive Spaces Occupancy: Warehouse or Parking Garage : Other Qualification Checklist No,:e: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly ind cate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or,3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T-1, T-2, T-4, T-5, T-8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw-in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <=150w c) electronic ballasts 3. LED lights. TABLE 15-1 Unit Lighting Power Allowance (LPA Use' LPA` (W/ft`) Use' LPAz(W/ft`) Automotive facility 0.85 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1-3 Occupancies 0.90 Cafeterias, fast food establishments5, restaurants/bars5 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail15, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group I-1 and 1-2 Occupancies 1.20 Transportation 0.80 Hotel/motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries5 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies' (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15-1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w/ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three -quarter -height partitions (transparent or opaque) and lighting for free-standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items II and iii below; ii. 1.4 watts per square foot of furniture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items!, II, or III above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling -mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Prcject Address CACHE Date 4/16/2013 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2009 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) Yes 1513.1 Local control/access Schedule with type, indicate locations E-2 Yes 1513.2 Area controls Maximum limit per switch E-2, E-3 N.A. 1513.3 Daylight zone control Schedule with type and features, indicate locations M.A. vertical glazing Indicate vertical glazing on plans M.A. overhead glazing Indicate overhead glazing on plans Yes 1513.4 Display/exhib/special Indicate separate controls E-2 14.A. 1513.5 Exterior shut-off Schedule with type and features, indicate location N.A. (a) timer w/backup Indicate location N.A. (b) photocell. Indicate location Yes 1513.6 Inter. auto shut-off Indicate location N.A. 1513.6.1 (a) occup. sensors Schedule with type and locations Yes 1513.6.2 (b) auto. switches Schedule with type and features (back-up, override capability), Indicate size of zone on plans E-2 N.A. 1513.7 Hotel/motel controls Indicate location of room master controls N.A. 1513.8 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514 Yes Ir 1514 Max. watts Indicate watts for each exit sign E-2 LIGHTING POWER ALLOWANCE (Section 1530-1532) Yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture E-2 N.A. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) N.A. 1511 IElec motor efficiency MECH-MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERS (Section 1540) N.A. 1540 Transformers Indicate size and efficiency If "no" is circled for any question, provide explanation: 41kERMiT COORD COP PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-122 DATE: 06/19/13 PROJECT NAME: CACHE SITE ADDRESS: 221 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # I after Permit Issued DEPARTMENTS: /Q Ct1I� Building Division Public Works Am OA b:1 -i3 Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete it Incomplete ❑ DUE DATE: 06/20/13 Not Applicable ❑ Comments: Permit Center. Use. Only, INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: TUESITHURS OUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 07/18/13 Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 'AIIPERMIT LOORD COP, PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-122 DATE: 05/06/13 PROJECT NAME: CACHE SITE ADDRESS: 221 SOUTHCENTER MALL Original Plan Submittal X Response to Incomplete Letter # I Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: PN,/G 05-•0.I1 Building Division II Fire Prevention Planning Division Public Works Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05/07/13 Complete 1 Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only: INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 06/04/13 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit CenterrUseOnly CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 1110PERMiT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-122 DATE: 04/18/13 PROJECT NAME: CACHE SITE ADDRESS: 221 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPA TMENTS: T v Building Division Wo s` i?g 1143-1. Public Fire Prevention Structural 01{, t3 ■ -.'� A//+ `+23-13 Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 04/23/13 Incomplete Not Applicable ❑ Comments: [Permit CO* Use Only NCO MPLETE LETTER MAILED: 1#';')` ff.l LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg' Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/21/13 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: PLAN REVIEW CHECKLIST - (Nonstructural) Permit App. By: IBC Edition b, & State Amend. Date: 7- Project title: Cac`i� +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 0.Classify the building or portion thereof in accordance with Chapter 3 —Determine the type of construction of the building in accordance with Chapter 6. Determine if the location of building on the site and clearances to property lines and other buildings on the site plan are in accordance with code provisions. Review for conformity with General building height and area limitations in accordance with Chapter 5. Review for conformity with special detailed requirements based on use and Occupancy. Review for conformity with Type of Construction requirements of Chapter 6. QReview for conformity with Fire and Smoke protection features of Chapter 7. Review for conformity with requirements of interior finishes of Chapter 8. Review for conformity with requirements for fire protection systems of Chapter 9. 12)/ Review for conformity with requirements for means of egress requirements of Chapter 10 Q" Review for conformity with requirements of accessibility in accordance with Chapter 11, and ICC A117.1 Review for conformity with Washington State Energy Code. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ✓ In circle = topic has been reviewed for the application. X In circle = topic is not relevant to proposed scope of work. PROJECT NAME: • cam, SITE ADDRESS: IAA -C M" PERMIT NO: • t '-1Z2 ORIGINAL ISSUE DATE: REVISION LOG REVISION NO. DATE RECEIVED DU 11\13 C, W7 STAFF INITIALS z 447 ISSUED DATE - i i ltA l V STAFF INITIALS LII 1 Summary of Revision: Received by: MANI MGn4`0 l� REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: ° (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: [] Response to Incomplete Letter # [] Response to Correction Letter # Revision # k after Permit is Issued 0 Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: 21)7/ I6/V r _ 71/44'J/- 1/Ui%�- 961741 Contact Person: 744,?G727 )67Z/ CI Phone Number: ",6. / Summary of Revision: /8��zoli.I '61 /000,1/3 ("ITV 0% t. JUN 11 2013 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all meas of revision-ineludiiig''date of revision .' Received at the City of Tukwila Permit Center by: VMS` Entered in Permits Plus on H:\Apphcations\Forms-Applications On La1162010 Applications\7-2010 - Revision Submittal.doc Created: 8-13-2004 Revised: 7-2010 Cit i City f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: " / �J Plan Check/Permit Number: Response to Incomplete Letter # l ❑ Response to Correction Letter # Revision # Project Name: after Permit is Issued reildi s Examiner Project Address: f/ j/Z L Contact Person: /V Phone Number: �� ¢ a/— /-e-,/ Summary of Revision: 7/W—(7i7 ,OG>Gl' MAY 062013 .'"41411 CENTEA Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: /1"/`----- Entered 1"/`----- Entered in Permits Plus on OSkel 11) H:\Applications\Forms-Applications On Line\2010 Applications V-2010 - Revision Submittal.doc Revised: May 2011 April 23, 2013 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Margo Kozich Commercial Permit Group 2136 Purcell Dr Fernandina, FL 32034 RE: Incomplete Letter #1 Development Permit Application Number D13-122 Cache — 221 Southcenter Mall Dear Ms. Kozich, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on April 18, 2013 is determined to be incomplete. Before your application can continue the plan review process the attached/following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433-7163 if you have any questions regarding the attached comments. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File No. DI3-122 W: Permit CenterlIncomplete Letters120131D13-122 Incomplete Letter #l.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • Tukwila Building Division Allen Johannessen, Plan Examiner Determination of Completeness Memo Date: April 23, 2013 Project Name: Cache Permit #: D13-122 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide an egress plan for this tenant that clearly identifies the, unobstructed, common path of egress leading to the exit discharge. Emergency illumination shall be provided along the common paths of egress and shall have at least an average 1 foot-candle and a minimum at any point of 0.1 foot candle measured along the path of egress at the floor level. Emergency lighting shall also be required for exit discharge doorways and any related discharge components that lead to a public way. (IBC 107.2.3 & Section 1006) 2. The reflective ceiling plan provided is not clear and difficult to read. Provide a revised readable reflective ceiling plan. Should there be questions concerning the above requirements, contact the Building Division at 206-431-3670. No further comments at this time. Contractors or Tradespeople Per Friendly Page Page 1 of 2 General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company PWI CONSTRUCTION INC 4804610777 155 West Main St Mesa AZ 85201 Out Of State Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602304814 Active PWICOCI976MC Construction Contractor 6/30/2003 12/11/2013 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status JOEEWI`044RS JOE E WOODS INC Construction Contractor General Unused 12/10/1996 11/14/2001 Archived PRICEWI081L9 PRICE WOODS INC Construction Contractor General Unused 6/29/1992 3/12/2003 Archived Business Owner Information Name Role Effective Date Expiration Date ('RICE, JEFFREY D President 07/03/2003 Amount PRICE, JEFFREY D Secretary 07/03/2003 DTEC07614B96C0F12 FERGUSON, MARC D Treasurer 07/03/2003 FERGUSON, MARC D Vice President 07/03/2003 Phoenix Insurance Company, The Bond Information Bond Bond Company Name Bond Account Number Hartford Fire Ins Co 59BSBFU5781 Effective Date 02/28/2011 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount $12,000.00 Received Date 03/21/2011 WESTERN SURETY CO 929277707 06/24/2003 Until Cancelled 07/23/2011 $12,000.00 06/30/2003 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 9Charter Oak Fire Ins Co DTEC07614B96C0F12 07/01/2012 07/01/2013 $1,000,000.00 06/25/2012 3 Phoenix Insurance Company, The DTEC0761413962IND1107/01/2011 07/01/2012 $1,000,000.00 07/05/2011 7 PHOENIX INS CO DTEC07614139621ND10 07/01/2010 07/01/2011 $1,000,000.00 06/29/2010 u TRAVELERS INDEMNITY CO OF AME DTC076146962INDLO9 07/01/2008 07/01/2010 $1,000,000.00 06/22/2009 5 TRAVELERS INDEMNITY CO OF AME DTC07614B962TIL07 07/01/2007 07/01/2008 $1,000,000.00 12/07/2007 'Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period h ans://fortress.wa. eov/1ni/bbin/Print. asnx 05/28/2013 MALL CIRCULATION SEE EXISTING STOREFRONT PLAN ON DWG #ID -5 DATITIO\ PLA\ 1/4" = 1'-0" 9D p. ADJACENT TENANT 5,-511" "S 1 FURR OUT WALL FOR RECESSED STANDARDS 1 SHOW WINDOW SHOW WINDOW VERIFY SEMI RECESSED FIRE EXTINGUISHER CAB. MOUNTED @ 55" AT TOP OF CAB. CAB IS LESS THAN 75' TRAVEL DISTANCE FROM ALL AREAS OF TENANT SPACE. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 8'-3" 6'-2" SALES FLOOR 24'—1 "VERIFY "I N II I V' \ R� 3'-0" 2'-2' 4,-0" 4,-0" r) FITTING ROOM FITTING ROOM 6'-2" 6'-2" f II '-2 2'-2' 35,— If 5'-1 5'— 2 ADJACENT TENANT 300 SC EDULE OENTRY — FITTING O ROOM — SALON OFITTING — ROOM OSTOCK ROOM OTOILET ROOM DOUBLE 3'-0" x ±8'-0" (FIELD VERIFY) x 1/2"TH CLEAR TEMPERED GLASS DOORS. "VIRGINIA GLASS" DOOR STYLE "BP" W/ CONTINUOUS 4"H BOT. SQUARE RAIL & TOP PATCH PIVOT HINGE. SINGLE ACTING IN—SWINGING DOORS W/ STANDARD BOTTOM RAIL LOCK #VIR-58 & STRAIGHT THROW BOLT (KEY ON MALL SIDE — THUMB TURN ON CACHE SIDE). CYLINDER TO BE INSTALLED MUST BE "BEST" MORTISE CYLINDER W/ INTERCHANGEABLE CORE. CACHE'S DISTRICT MGR. WILL BE RESPONSIBLE FOR INSTALLING "BEST CORE LOCK". SPRING DUSTPROOF FLOOR STRIKE COVER (POPS UP WHEN DOOR IS NOT LOCKED). ALL METAL FINISHES TO BE SATIN STAINLESS STEEL, #8. DOORS W/ HARDWARE AVAILABLE FROM: VIRGINIA GLASS TEL: 1-800-368-3011. PUSH—PULL HARDWARE: "ELMES, INC" #T1780, FINISH: ANODIZED SILVER LEFT: #T1780 -25-038—L BACK TO BACK RIGHT: #T1780 -25-038—R BACK TO BACK INSTALL EXTRA RECESSED FLOOR STRIKES FOR EACH DOOR TO LOCK DOORS IN "HOLD OPEN POSITION". CEILING HEIGHT OPENING W/ FABRIC CURTAIN SET IN 4"H RECESS. HARDWARE SUPPLIED BY CACHE, INSTALLED BY ONSITE G.C. CEILING HEIGHT OPENING W/ FABRIC CURTAIN SET IN 4"H RECESS. HARDWARE SUPPLIED BY CACHE, INSTALLED BY ONSITE G.C. CURTAIN W/ CURTAIN W/ 3'-0" x 6'-8" x 1 3/4" TH. HOLLOW METAL FLUSH DOOR W/ STANDARD FRAME. FINISH FITTING ROOM SIDE OF DOOR PLAST. LAM. PROVIDED BY CABINETRY CONTR., APPLIED BY ONSITE MILLW.:. CONTRACTOR). PAINT FINISH FRAME & STOCK ROOM SIDE OF DOOR 4 . — 2 PAIR STANLEY 4" BUTT HINGES SATIN ST. STL #4 FINISH. — "SCHLAGE" S SERIES JUPITER LEVER STORAGE LOCK SET, FINISH 626 SATIN CHROME. — 8"x34" KICK PANEL ON FITTING ROOM SIDE, FINISH #626 BRUSHED ST/STL. — CONCEALED OVERHEAD SELF—AUTOMATIC DOOR CLOSER "LCN SUPER SMOOTHIE" SERIES #4040 ON STOCK ROOM SIDE. 3'-0" x 6'-8" x 1 3/4" TH. HOLLOW METAL FLUSH DOOR W/ STANDARD FRAME. FINISH:PT1 ALL SIDES . — 2 PAIR STANLEY 4" BUTT HINGES SATIN ST. STL #4 FINISH. — "SCHLAGE" S SERIES JUPITER LEVER PRIVACY LOCK SET, FINISH 626 SATIN CHROME. DOOR & FRAME COMPLETE W/ HARDWARE SUPPLIED BY CABINETRY CONTRACTOR, INSTALLED BY ON SITE MILLWORK CONTRACTOR. OCLOSET — N/A REAR 0 SERVICE — ENTRY EXISTING 3'-0" X 7'-0" "B" LABEL SERVICE DOOR. FINISH EGRESS CORRIDOR SIDE OF DOOR / FRAME PAINT (PT1 )PAINT SERVICE CORRIDOR SIDE OF DOOR / FRAME & PROVIDE SIGNING AS PER LANDLORD REQUIREMENTS. ON SITE G.C. TO INSTALL THE FOLLOWING ITEMS: • OVERHEAD AUTOMATIC DOOR CLOSER ON CACHE SIDE OF DOOR (INSIDE) "LCN SUPER SMOOTHIE" OR EQUAL. • FIRE EXIT DEVICE W/ BATTERY ALARM BY "DETEX" OR, EQUAL. • DEADLOCK—BLANK FACE PLATE AT CORRIDOR SIDE, PUSH BAR OPERATED AT INSIDE. SELF LATCHING FEATURE WHEN DOOR IS CLOSED. • UL—RATED PEEP HOLE AT +60"AFF • SYMBOL 1 FURR OUT WALL FOR RECESSED STANDARDS PATITIO\ L DESCRIPTION -C N 3 FULL HEIGHT DEMISING PARTITION. PATCH / REPAIR GYPSUM BOARD WHERE NECESSARY TO MAINTAIN 1 HR FIRE RATING PER UL #U495. PREPARE WHERE NECESSARY TO RECEIVE NEW FINISH. NEW NOMINAL 5" TH. CEILING HEIGHT PARTITION WITH 3 5/8" (20 GA.) MTL STUD FRAMING AT 16" O.C, WITH 5/8" TYPE "X" GYPSUM BOARD EACH SIDE. EXTEND MTL STUDS TO 6" ABOVE FINISHED CEILING & SECURE W/ DIAGONAL BRACING TO STRUCTURE ABOVE (NOT DECK). EXTEND GYP. BD ON STOCK ROOM SIDE TO 3" ABOVE ACOUSTIC TILE CEILING. EXTEND GYP. BD ON FITTING ROOM & SALES FLOOR SIDES TO FINISHED CEILING. NEW CEILING HEIGHT PARTITION W/ (20 GA) METAL STUD FRAMING & SOUND ATTENUATION BLANKET. APPLY ONE LAYER 5/8" WATER RESISTANT GREENBOARD ON TOILET ROOM SIDE AND 5/8" TYPE "X" GYP. BD ON FITTING ROOM SIDE. EXTEND METAL STUD FRAMING TO 3" ABOVE FINISHED CEILING. EXTEND GYPSUM BOARD / GREENBOARD TO FINISHED CEILING. NEW ±4 5/8"DEEP CEILING HEIGHT PLUMBING CHASE W/ 4" (18 GA) METAL STUD FRAMING. APPLY ONE LAYER 5/8" WATER RESISTANT GREENBOARD ONE SIDE. EXTEND GREENBOARD & MTL STUDS TO FINISHED CEILING. NEW 2 3/8" DEEP (VERIFY IN FIELD) CEILING HEIGHT FURR—OUT W/ 1 5/8" METAL STUD FRAMING. APPLY ONE LAYER 5/8" TYPE "X" GYP. BD. EXTEND METAL STUD FRAMING TO 3" ABOVE FINISHED CEILING. EXTEND GYPSUM BOARD TO FINISHED CEILING. NEW NOMINAL 3 3/4" TH. CEILING HEIGHT PARTITION WITH 2 1/2" (25 GA.) MTL STUD FRAMING AT 16" O.C. WITH 5/8" TYPE "X" GYPSUM BOARD EACH SIDE WHERE REQUIRED (SEE PLAN). EXTEND MTL STUDS & GYP. BD TO FINISHED CEILING. G.C. TO INSTALL BLOCKING FOR FITTING ROOM GARMENT HOOKS. SEE DETAIL A, ID -8 NEW COLUMN ENCLOSURE, APPLY ONE LAYER 5/8" TYPE "X" GYPSUM BOARD OVER METAL FRAMING. EXTEND GYP. BD & FRAMING TO DECK ABOVE. TAPE / SEAL TO MAINTAIN 1 HR FIRE RATING. 5" 3" VERTICAL GRAB BAR TD COMPLY W/ ANSI 604.5.1 GRAB BAR 5/8" TYPE "X" GYP. BD. CLG. 1 3'-3" U 1'-0"MAk 0 3'-6" 4"BASE TOILET PAPER HOLDER 5/8" TYPE "X" GYP. BD. CLG. 36" GRAB BAR GRAB BAR 18"x36" MIRROR 8'-O" TOILET ROOM CEILING HEIGHT WA! LIM N TO TOP OF MIRROR TO 18 HOLD LET OOV 5"\4"BASE VATIO\ S 3/8" = 1'-0" SEPARATE: PERMIT REQUIRED FOR; lierthichanical Iectrical [dumbing (,was Piping City of Tukwila BUILDING DIVISION STRIPE FLOOR TO INDICATE 44" CLEAR PATH OF TRAVEL. BACK DOOR TO HAVE TENANT NAME AND ADDRESS WITH 1" HIGH WHITE LETTERS ON 2" RED VINYL TAPE PER MALL CRITERIA. 36" H. KNEE WALL TO SEPARATE PATH OF EGRESS DATE: 3.26.2013 JOB NO: DRAWN: CHECKED: 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 FILE COPY Permit Nb.Vi3 ‘246 Plan review approval is s *SKIM and plibionti. Approval of construction documents does not authorize thy, violation of any adopted code or ordhiance. Receipt of approved Field Copy and old le acknowledged: By �` w Deg .Z (p o fli-.. 7h1 "1:-) Oty OflbIa BUILDING DIVISION NOTE: G.C. TO VE FY ALL DIVE\ BEGIN AND_ MM A SIO\S B=FNE NINE CO\STR,CTIO\, E3IATELY .EPOS{, N Y VA I A TI O\ S TO THE OJ -CT CON3INATN D G.C. COORDINATION FOR SECURITY SYSTEM: PRIOR TO: CLOSING IN ENTRY COLUMN ENCLOSURES, BUILDING SHOW WINDOW PLATFORMS, INSTALLING TILE FLOORING & PREFERABLY AFTER ALL SALES AREA FLUORESCENT LIGHTING HAS BEEN INSTALLED — THE ON SITE G.C. IS TO CONTACT: "XPONDR" ATTN: FIELD SERVICE PH: 888-601-4800 TO COORDINATE SECURITY SYSTEM INSTALLATION UNDER FLOOR & IN ENTRY SOFFIT. REFER TO "XPONDR" DETAILS ON DWG #ID -4 & #E-1. A \D CAP 3A CONSTRUCTION NOTES: 1. ON SITE G.C. SHALL VERIFY ALL FIELD CONDITIONS & SHALL HAVE SOLE RESPONSIBILITY FOR VERIFICATION OF CLEAR HEIGHTS & FLOOR DEPRESSIONS WITHIN THE BASE BUILDING. 2. ON SITE G.C. PRIOR TO ERECTING ANY NEW PARTITIONS TO FIELD SURVEY & COORDINATE ALL CLEAR DIMENSIONS W/ CABINETRY CONTRACTOR TO ENSURE PROPER FIT OF CASEWORK & FIT. RMS. — THERE IS NO MARGIN FOR ERROR. 3. ON SITE G.C. TO REFER TO DWG #ID -8 FOR ALL DRYWALL / WOOD CAP DETAILS AND CONDITIONS. 4. ON SITE G.C. TO APPLY NEW FIRE CAULKING ALONG DEMISING WALLS OR PATCH/REPAIR EXISTING FIRE CAULKING. FIELD VERIFY EXISTING CONDITION. E� E SEE TO LET -QU EVE\ U REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 5 2013 A k City of Tukwila. BUILDING DIVISION SOUTHCENTER MALL SPACE 6040 i\ 4.30.2013 A 6.5.2013 QO 000 00 C) Q Q J I- W F- z W 0 I. F- 0 cr.) r N CV RECEIVED CITY OFTUKWILARE/iSiON NO1...± TS JUN 19 2013 WATER CLOSET LAVATORY FAUCET DOOR FLAT MIRROR TOILET PAPER HOLDER PAPER TOWEL BAR GRAB BARS "AMERICAN STANDARD" CADET ADA 165-"H ELONGATED TOILET #2998!OIT CENTER LOW CONSUMPTION 1.6 GA FLUSH. WHITE VITREOUS CHINA. PROVIDE WHITE STANDARD SOLID PLASTIC OPEN END SEAT, +18"MAX SEAT HEIGHT. "OLSONITE" #10CC WHITE — OR APPROVED EQUAL. "AMERICAN STANDARD" COMRADE WALL HUNG LAVATORY #0124.131, 18 1/4"D x 20"W W/ 4" 0.C. CENTERS & CONCEALED ARM SUPPORTS. WHITE VITREOUS CHINA. INSTALL RIM TOP NO HIGHER THAN +34" AFF. PROVIDE MINIMUM +29" AFF. TO BOTTOM OF APRON FOR KNEE CLEARANCE. HOT WATER & DRAIN PIPES UNDER LAVATORY SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. "AMERICAN STANDARD" MONTERREY #7502.170 CENTER SET LAVATORY FAUCET W/ GOOSENECK SPOUT, WRIST BLADE HANDLES, GRID STRAINER DRAIN, & FLOW RESTRICTORS. POLISHED CHROME FINISH. SEE DOOR SCHEDULE TYPE O ON THIS DRAWING. "BOBRICK" #B-290 1836 SURFACE MTD SATIN ST/STL FRAMED MIRROR 18"W x 36"H. MOUNT BOT. OF MIRROR AT +40"AFF, CENTER MIRROR OVER LAVATORY. — POLISHED CHROME SURFACE MTD TOILET PAPER HOLDER. MOUNT CENTER OF HOLDER AT +19" AFF. & WITHIN 7" TO 9" FROM FRONT EDGE OF TOILET SEAT. — POLISHED CHROME ROLLER TOWEL BAR, 12" LONG. MOUNT BAR AT + 42" AFF. ON WALL ADJACENT TO LAVATORY. "BOBRICK" 8-6106 x 36" LONG STRAIGHT GRAB BAR MOUNTED ON WATER CLOSET REAR WALL W/ END OF BAR SET 6" FROM INSIDE CORNER. "BOBRICK" B-6106 x 42" LONG STRAIGHT GRAB BAR MOUNTED ON WATER CLOSET SIDE WALL W/ END OF BAR SET 12" FROM INSIDE CORNER. STAINLESS STEEL TUBING 1 1/2" O.D. W/ WELDED FLANGES. MOUNT GRAB BARS AT +35" AFF. TO CENTER OF BAR. BAR FASTENERS & MOUNTING SUPPORT SHALL BE ABLE TO WITHSTAND 250 LBS./FT. IN BENDING, SHEAR, & TENSION. REVISIONS aEG TEFF 00 ARC;HUS OT CORTLAND MORGAN STAT; c:)F PARTITION PLAN SHEET NUMBER ID -3 BRUSHED BRONZE FLOORING ANGLE 1/8"TH x 3/8"H x 1 1/2"L (BY ON SITE G.C.) GLUE -DOWN CARPET Car)— FEATHER EDGE CARPET SO THAT ALL FINISHES ALIGN — ALIGN — LEASE LINE MATCH MALL TILE TO CENTERLINE OF STOREFRONT CLOSURE *1 MALL CIRCULATION INDICATES SAWCUT CHANNEL UNDER FLOOR TILE FOR "XPONDR" LOOPWIRE EXISTING STOREFRONT TO REMAIN FLOOR PLAN LEASE LINE ADJACENT TENANT RECESSED STANDARDS, TYP. I—I ACCESSIBLE ADA BENCH, MOUNTED TO WALL i SEMI RECESSED ARE EXTINGUISHER CAB. MOUNTED 0 55" AT TOP OF CAB. CAB IS LESS THAN 75' TRAVEL DISTANCE FROM ALL AREAS OF TENANT SPACE. -t�--------✓ ---- –fit--- f-- ------------ ----------------------- ----------------------------------�-- -- ------------------- r,ra �. _t,; o'b., t,a 3„` s, .�,. r`:. ,. "a,, t.;, •r' b4 .'. µ .Ns t :fit+ma.+ ,#,. ,: ,bu y E rr"k^ a+aY" ” �; .�',- �3 , �E DESCRIPTION ------------- --- FITTING ROOM CURTAINED OPENING (INSTALLER TO FIELD MEASURE) CURTAIN SUPPLIED & INSTALLED BY CACHE'S DRAPERY CONTRACTOR F6 FITTING ROOM STOOL (FURNISHED BY CACHE) F8 v ALL ITEMS BELOW ARE FURNISHED BY CACHE & INSTALLED BY G.C. D2 - T�-- - FR# FIT. RM PACKAGE- WOOD TRIM ( COMPLETE W/ HDWR), BASE, BACK LIT MIRROR, STOOL, U -RAIL& BENCH AT HC FITTING ROOM M1 FITTING ROOM MIRROR UNIT 2'-"W X 8"-0'H, MOUNTED ON 4" BUILD -OUT W/ CONCEALED VERTICAL FLOURESCENT STRIP LIGHTING M2 FITTING AREA TRIPLE MIRROR UNIT 2'-0"W X 8'-0"H WI 4" BACKLIT FROSTED GLASS BORDER & 21" HINGED SIDE PANELS M3 FRAMED MIRROR UNIT (DIMENSIONS VARY- REFER TO ELEVATIONS DWG # ID -7) M5 FRAMED MIRROR UNIT (DIMENSIONS VARY- REFER TO ELEVATIONS DWG # 10-8) F1 SIDE SHOWCASE LINE W/ CASH WRAP UNIT & REAR WALL COUNTER F2 SALES FLOOR / WALL MTD HANGING WALL FIXTURE F5 -,...,,s,....___ F7 ADA COMPLIANT FITTING ROOM BENCH - MUST BE SECURED TO WALL H1 GARMENT HOOK MTD 6'-6" AFF H2 DRAPERY TIE BACK H3 GARMENT HANG BAR W/ BACK PANEL (PROVIDE BLOCKING IN WALL) S1 DESK AND CABINET- 2 -I 'D X 4'-0"L X 30"H S2 TISSUE PAPER UNIT 21"D X 30"L S3 HANGING / SHELVING UNIT 16"D X LENGTHS VARY FILE CAB. 4 DRAWER MTL FILE CABINET All 'vrl w\\ lip I \ FIRE -- I• WINDOW`) — EX. I � '� - 01 HOV11V - o o 4H46 Lxl,BbXG"i►Z I F8 ] ISS HON38 VOV - ID ED 'C.A..— P I■= 0 —1 •.;t 0 FITTING j9.A — ix I s ROOM i W \ ip ISI i _ / \ Z ce = mV / --1 a 0 I atw. FILE STORAGE n13 : Z4 ` g s L� CAB. — w o 8 N ` Q SALES AREA CO 8 �r► LEASE LINE I = C1 705 / L 8 i L_ £S £S £S £S £S £S £S _ J CLOTHES RAIL a - - \ (ABOVE) 4— M5 � \,� B1 TiDISP WINDO D1 CURTAIN, TYP. D1 CURTAIN, TYP. ...• ■ _• .. LS'tfYHL9. I I j 5J £HFITTING £FITTING 15A CM3 V I i ROO ROOM • 93 1/4" = 1'-0" PORCELAIN FLOOR TILE 17" x 17" ON THIN SET INSTALLATION SHIM / FEATHER EDGE TILE SO — THAT ALL FINISHES ALIGN —TOP OF CONCRETE SLAB FLOORING DETAIL FULL SIZE a ON SITE G.C. TO FIELD VERIFY EXISTING CONCRETE SLAB CONDITION. MODIFY SLAB TOPPING AS REQ'D. TO INSURE A UNIFORM FLOORING TRANSITION THRU-OUT SPACE. 18" CACHE INDICATES 1/4"Wx1/2"D SAWCUT CHANNEL BY ONSITE G.C. TO CONNECT ANTENNA RELIEFS WI LOOPWIRE CHANNEL PORCELAIN FLOOR TILE 17"x 17" ON THIN SET INSTALLATION ALIGN - 1/2"Wx1"D SAWCUT CHANNEL 1/2" BY ONSITE G.C. FOR "XPONDR" LOOPWIRE & ANTENNA CABLING. FLOORING DETAIL FULL SIZE 20min QUICKSET CEMENT BY ONSITE G.C. / 6 1/2" 1 /8"TH. SATIN ST. STL FLOORING ANGLE BY G.C. 6 1/2"x4 1/2"x1 1/2"D RELIEF CUT 4-- INTO EXISTING SLAB BY ONSITE G.C. FOR "XPONDR" ANTENNA INSTALLATION (3 REQUIRED). FLOOR ANTENNA SUPPLIED & INSTALLED BY "XPONDR" (3 TOTAL). MALL E-_ NEW GLASS PANEL ENTRY DOORS NEW MALL FLOORING FIELD VERIFY EXIST'G CONDITION VINYL COMPOSITION FLOOR TILE - TOP OF EXISTING CONCRETE SLAB FLOORING DETAIL FULL SIZE BRUSHED BRONZE FLOORING ANGLE 1/8"TH x 3/8"11 x 1 1/21. (BY ON SITE G.C.) PORCELAIN FLOOR TILE (T1 ON THIN SET INSTALLATION — ALIGN "MERCER" IMPERIAL C/E REDUCER STRIP STOCK No.700 COLOR No.201 BROWN r E' ! GLUE -DOWN CARPET PORCELAIN FLOOR TILE 12"x 24" ON THIN SET INSTALLATION — TOP OF CONCRETE SLAB t.> FLOORING DETAIL FULL SIZE ON SITE G.C. TO FIELD VERIFY EXISTING CONCRETE SLAB CONDITION. MODIFY SLAB TOPPING AS REQ'D. TO INSURE A UNIFORM FLOORING TRANSITION THRU-OUT SPACE. STRIPE FLOOR TO INDICATE 44" CLEAR PATH OF TRAVEL STRIPE WITH: ARMSTRONG EXCELON, LEMON YELLOW 51812 & CHERRY RED 51816 VCT 36" HIGH KNEE WALL TO SEPARATE PATH OF EGRESS RE VISION NO;j_ b 143' 412 - NON -COMBUSTIBLE BLOCKING MUST BE PROVIDED OR STIFFENERS INSTALLED IN LANDLORD DEMISING WALLS TO PREVENT STUD DEFLECTION AS THE RESULT OF SHELVING/FIXTURES MOUNTED TO DEMISING WALLS. FURR OUT AS REQUIRED TO ENSURE THAT STRUCTURAL INTEGRITY OF LANDLORD DEMISING WALLS REMAINS INTACT (TYP). REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 5 2013 • City of Tukwila BUILDING DIVISION ,5, 31 Aga yY. ... SYMBOL r,ra �. _t,; o'b., t,a 3„` s, .�,. r`:. ,. "a,, t.;, •r' b4 .'. µ .Ns t :fit+ma.+ ,#,. ,: ,bu y E rr"k^ a+aY" ” �; .�',- �3 , �E DESCRIPTION D1 FITTING ROOM CURTAINED OPENING (INSTALLER TO FIELD MEASURE) CURTAIN SUPPLIED & INSTALLED BY CACHE'S DRAPERY CONTRACTOR F6 FITTING ROOM STOOL (FURNISHED BY CACHE) F8 FITTING ROOM SALON - OTTOMAN (FURNISHED BY CACHE) ALL ITEMS BELOW ARE FURNISHED BY CACHE & INSTALLED BY G.C. D2 LAMINATE- APPLIED TO FITTING ROOM SIDE OF DOOR. SEE DOOR SCHEDULE ON DWG # ID -3 FR# FIT. RM PACKAGE- WOOD TRIM ( COMPLETE W/ HDWR), BASE, BACK LIT MIRROR, STOOL, U -RAIL& BENCH AT HC FITTING ROOM M1 FITTING ROOM MIRROR UNIT 2'-"W X 8"-0'H, MOUNTED ON 4" BUILD -OUT W/ CONCEALED VERTICAL FLOURESCENT STRIP LIGHTING M2 FITTING AREA TRIPLE MIRROR UNIT 2'-0"W X 8'-0"H WI 4" BACKLIT FROSTED GLASS BORDER & 21" HINGED SIDE PANELS M3 FRAMED MIRROR UNIT (DIMENSIONS VARY- REFER TO ELEVATIONS DWG # ID -7) M5 FRAMED MIRROR UNIT (DIMENSIONS VARY- REFER TO ELEVATIONS DWG # 10-8) F1 SIDE SHOWCASE LINE W/ CASH WRAP UNIT & REAR WALL COUNTER F2 SALES FLOOR / WALL MTD HANGING WALL FIXTURE F5 FITTING ROOM WALL MTD GARMENT "U" BAR & PURSE TABLE F7 ADA COMPLIANT FITTING ROOM BENCH - MUST BE SECURED TO WALL H1 GARMENT HOOK MTD 6'-6" AFF H2 DRAPERY TIE BACK H3 GARMENT HANG BAR W/ BACK PANEL (PROVIDE BLOCKING IN WALL) S1 DESK AND CABINET- 2 -I 'D X 4'-0"L X 30"H S2 TISSUE PAPER UNIT 21"D X 30"L S3 HANGING / SHELVING UNIT 16"D X LENGTHS VARY FILE CAB. 4 DRAWER MTL FILE CABINET RECEIVED CITY OF TUKWILA JUN 192013 PERMIT CENTER DATE: 3.26.2013 JOB NO: DRAWN: CHECKED: 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 SOUTHCENTER MALL SPACE #640 A 4.30.2013 A 6.5.2013 8897 REVISIONS REGISTERED ARCHITECT CORTLAiNJD MORGAN STATE OF WA 'HU G FLOOR PLAN SHEET NUMBER D-4 RECESSED CLG MTD ELECTRICAL DUPLEX OUTLET CACHE SUPPLIED 5' LONG BANNER TRACK SURFACE MOUNTED AS SHOWN BY ON-SITE G.C. EXISTING STOREFRONT TO REMAIN EXISTING 5/8" TYPE "X" GYP. BD SOFFIT TO REMAIN PT2 STAGGERED DOUBLE TUBE FLUORESCENT LIGHT FIXT., TYPE F FACE OF GYP. BD DEMISING PARTITION GYP. BD. W/ PAINT FINISH H ADJACENT TENANT NEW GYP. BD. CEILING AT EXISITING HEIGHT. PAINT PT2 TYP. (ALL FRONT OF THE HOUSE LOCATIONS) GYP. BD. TROUGH TO RECESS TRACK LIGHTING. SEE DETAIL THIS SHEET GYP. BD. CEILING PAINT PT2 NEW 24"x48" ACOUSTIC TILE LAY -IN CLG AT +11'-6" AFF. (STOCK ROOM LOCATION ONLY) J H 1'-2" J" 0 A 0 1 7'-0" 7'-D" A 0 I I 1 7'-D" r • RUN VERTICAL FIRE PIPE IN THIS LOCATION (IF REQUIRED) 11 -- CAT 5 CABLE FOR "PEOPLE COUNTER" n 0 L, FLUSH 24" x 24" ACCESS DOOR MTD IN ENTRY SOFFIT. "MILCOR" STYLE ATR W/ CYLINDER KEY LOCK. FIELD INSTALL GYP. BD FACING & CASING BEADS. FINISH TO MATCH CEILING. CACHE SUPPLIED 5' LONG BANNER TRACK SURFACE MOUNTED AS SHOWN BY ON-SITE G.C. A 7'-0" 7'-0" A 7'-0" L. H - R J 0 7'_O" 7'-0" A A J 0 A I I 7'-O" 7.-0" A F A I iCI I i 1'-11" ADJACENT TENANT REFLECTED CEILING / LIGHTING PLAN 1/4" = 1'-0" SECTION 2'-1" z 0 I ; 44 4 //14 , / P i,- / / I / / / / 2TUD6 (O GA) METAL — 5/81/TYPE "X" BD, WIC COVER MAIN SUSPENSION SYSTEM AS MANUFACTURED BY USG INTERIORS "RIGID X - DONN SUSPENSION SYSTEM" OR EQUAL SECURED TO BOT. BOT OF STRUCTURE ABOVE W/ VERTICAL HANGER WIRE (9 GA) CEILING 5/8" TYPE "X" GYP. BD, PAINT "UGHTOLIER" CMH LAMP HOLDER ON CONT. SUSPENDED TRACK GYP. BD SOFFIT BOT. PAINT PT2, TYP. GYP. BD HEADER BOT. PAINT PT2) FINISH 1. ON SITE G.C. TO PROVIDE & INSTALL A MASTER CONTROL SWITCH FOR ALL LIGHTING (EXCEPT SHOW WINDOW LIGHTING). 2. ALL EMERGENCY LIGHTING, EXIT SIGNS, AND NIGHT UGHTS SHALL BE WIRED TO THE PANEL BOARD, AHEAD OF ANY LOCAL SWITCHING. CONSTRUCTION NOTES: 1. * SYMBOL INDICATES EMERGENCY UGHT1NG LOCATIONS. REFER TO LIGHTING LEGEND THIS DRAWING FOR FIXTURE SPECS. 2. ON SITE G.C. TO PROVIDE ACCESS TO ALL DUCTWORK, HEATERS, PIPING, CONTROLS, OR VALVES LOCATED WITHIN THE PREMISES (WHETHER TENANT OR BASE BUILDING SYSTEMS) BY MEANS OF ACCESSIBLE CEILING TILE OR FLUSH ACCESS PANELS. 3. CEILING SYSTEMS TO BE SUSPENDED FROM STRUCT. STEEL ONLY. CONNECTION TO LANDLORD'S METAL DECK IS NOT PERMITTED. 4. ALL ELECTRICAL AND MECHANICAL COMPONENTS ABOVE CEILING TO BE GROUPED TOGETHER AND LOCATED OVER STOCK ROOM AS MUCH AS POSSIBLE TO KEEP THE QUANTITY OF REQUIRED CEIUNG ACCESS PANELS TO A MINIMUM. ALL ACCESS PANELS TO MATCH PANEL SPECIFIED IN ENTRY VESTIBULE. REVISION NO1T t?i3122 REVIEWED FOR ,ODE COMPLIANCE APPROVED 'JUN 2 5 2013 BUILDING of DIVISION LIGHTING LEGEND SYMBOL MANUFAC-URER MODEL # LAMP VOLTAGE NUMBER DESCRIPTION A A 0 -, L____J A UGHTOUER 8242HU 8038CLW/1951 (2) 33W CFL 120V / 66W - SALES FLOOR COMPACT FLUORESCENT 2 LAMP 8" OPEN REFLECTOR DOWNUGHT W/ CLEAR ALZAK CONE & WHITE FLANGE, INTEGRAL ELECTRONIC BALLAST r- --1 A ILQ*J UGHTOUER 8242HU 8242H8038CW/1951 (2) 33W CFL 120V / 66W - SALES FLOOR EMERGENCY DOWNUGHT. SAME AS TYPE 'A' ABOVE WI EMERGENCY OPTION & ON 24 HR NIGHT UGHT CIRCUIT. a B a UGHTOUER Lhtolier #22SS3W #225S3WH 25W MAX 42345 - 13PAR30S/END/F25 3000 DIM 120V / - - CEILING MTD PERIMETER UGHT TRACK W/ LED LAMPS ALL PARTS WHITE FINISH. D L.i UGHTOUER 1002P1/1048 -25W MAX 422334 51-PAR30S/END/F25 120V / 13W - RECESSED (1) LAMP ADJUSTABLE SPOT LIGHT. MERCURY LIGHTING STAG SERIES (2) T5 28W BULBS (2) T5 21W BULBS - 120V / 56W 120V / 42W - - - STAGGERED DOUBLE TUBE FLUORESCENT LIGHT STRIPS 3', 4', & 6' LENGTHS W/ ELECTRONIC BALLAST F(4') 1.49" l'IF 3 37-1/4" 1111. 25-7/16" F2 LUKAS UGHTING CUSTOM (4) 13W 4 -PIN QUAD 120V / - - FITTING ROOM SALON CUSTOM PENDANT LIGHT FIXTURE. G` COLUMBIA FL4L2X4TRELE (2) 4' T-8 3500'K 120V / - - STORAGE ROOM RECESSED 2 X 4 LAY -IN 2 -LAMP FLUORESCENT LIGHT FIXTURE W/ ELECTRONIC BALLAST, & ACRYLIC LENS H H J JUNG LIGHTING Juno MS382WH-25W MAX 30045-13PAR3os/END/F2s 3000 DIM 120V / 25W - RECESSED FIXTURE FOR STOREFRONT WINDOW. SUITABLE FOR FOR EXTERIOR ENTRANCE DAMP LOCATION. LED LAMPS Q EX LIGHTALARMS SPLEDWRCD - 120V / - - SALES FLOOR / FITTING ROOM WALL OR CEILING MOUNTED EMERGENCY EXIT UGHT SIGN FIXTURE W/ BATTERY BACK-UP. CLEAR ACRYLIC PANEL W/ RED LETTERS & WHITE FACE PLATE. 1)421 EX2 PRESCOUTE NAPEXHC3RECCBW - 120V / - - STORAGE ROOM UNIVERSAL MOUNT EMERGENCY UGHT & EXIT SIGN FIXTURE W/ BATTERY BACK-UP. ALL INSTALLED THIS AND RECEIPT. 16- MSLIGHTING I'S- 1A MASTER SHUT-OFF SWITCH FOR ALL UGHTING - RECESSED CEIUNG MOUNTED AUDIO SPEAKER WITH GRILLE. CONTACTOR "GE460XEIB" ® "POSH 5.25 RETRO CEIUNG SPEAKER" FOR INSTALLATION IN CEIUNG TILE OR SHEETROCK, PREFINISHED WHITE GRILLE & BEZEL, SELF WALL MOUNTED LIGHT SWITCH CONTAINED IN STEEL HOUSING. AVAILABLE FROM: "DMX MUSIC" ATTN: MARISA CUPSON PH: 1 AMP CURRENT LIIMITER (800)831-8001 SPEAKER WI GRILLE SUPPLIED BY CACHE. INSTALL WI 16 GA RECEIVE OCCUPANCY SENSOR SWITCH #SPT/162 WIRE. CITY OF TU i ® SAME AUDIO SPEAKER & GRILLE SPEC AS ABOVE - EXCEPT W/ BUILT-IN UGHT FIXTURES AND LAMPS WILL BE FURNISHED BY CACHE AND THUMB SCREW VOLUME CONTROL (VERIFY EXACT LOCATION IN FIELD). JUN 1 9 21 BY TENANT'S CONTRACTOR, UNLESS OTHERWISE NOTED. CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING, STORING, PROTECTING FROM THEFT, BREAKAGE, ETC, AFTER SIGNING FOR PERMIT CEN D WILA 13 TER DATE: 3.26.2013 JOB NO: DRAWN: CHECKED: 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 U SOUTHCENTER MALL SPACE 1640 A 4.30.2013 6.5.2013 8897 REVISIONS REGISTERED ARCHITECT CORTLAND MORGAN STATE OF W::Q H ° i N co 00 T oct I.L W W 0 O N REFLECTED CEILING PLAN SHEET NUMBER ID -4a CONTINUE WC2 WALLCOVERING AROUND CORNER AND WRAP ALL SIDES OF VALANCE, TYP. RAILROAD WALLCOVERING PATTERN ALONG VALANCE. RAILROAD WALLCOVERING PATTERN ALONG VALANCE. (WC2) (PT1) 0-11Fi) ow) MOUNT DRAPERY TIE BACKS HORIZONTAL (DO NOT ANGLE) WC2 1<-71T) / / S / r (PT1) SIM • • • e CD N I XXXXXXXIXXX OPEN TO FITTING AREA MIME LI « Fl CASH WRAP B1 ELEVATION NOTE: ALL CEIUNG FINISHES TO BE PT2 UNLESS OTHERWISE NOTED ELEVATION 1/4" = 1'-0" 1/4" = 1'-0" FULLY SECURE MIRROR W/ TWO SET OF STEEL CLEATS (TOP & BOTTOM) PROVIDE BLOCKING TO SUPPORT UP TO 300 LBS. CONTINUE WC2 WALLCOVERING AROUND CORNER AND WRAP ALL SIDES OF VALANCE, TYP. EXISITNG STOREFRONT CLEAN & REPAIR AS REQUIRED. ANIIII PI 111111 VA MI II IA 11111111111 IA M3 ELEVATION 1/4" = 1'-0" ELEVATION 1/4" = ii -o- FULLY SECURE MIRROR W/ TWO SET OF STEEL CLEATS (TOP & BOTTOM) PROVIDE BLOCKING TO SUPPORT UP TO 300 LBS. FULLY SECURE MIRROR W/ TWO SET OF STEEL CLEATS (TOP & BOTTOM) PROVIDE BLOCKING TO SUPPORT UP TO 300 LBS. REVISION. NO.LL INDICATES BLOCKING FOR SECURING ADA COMPATIBLE BENCH G.C. TO INSTALL ONE TYPE H1 HOOK AT THIS LOCATION — +3'-0" AFF DATE: 3.26.2013 JOB NO: DRAWN: CHECKED: 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 REVIEWED FOR 4ODE COMPLIANCE APPROVED I JUN 2 5 2013 City of Tukwila UItDING DIVISION U ELEVATION M2: LIGHTED, HINGED TRIPLE MIRROR UNIT ELEVATION ELEVATION 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" ELEVATION 1/4" = 1'-0" ELEVATION 1/4" = 0" NOTE: PROVIDE BLOCKING FOR ALL MIRRORS TO SUPPORT UP TO 300 LBS. B1 M1 BACK—UT FRAMED MIRROR ELEVATION 1/4" = 1'-0" PT1 ELEVATION 1/4" = 1'-0" DF2)----« W 01'1 )1 Ica m M1 BACK—UT FRAMED MIRROR ELEVATION 1/4" = l'-0" TYPICAL FITTING ROOM N +--( DF2) I� • ELEVATION 1/4- = (PT1) ELEVATION 1/4" = ELEVATION 1/4" = 1'-0" ELEVATION 1/4" = 1'-0" ADA FITTING ROOM z ,,,� .„, l..,t ,.. .,.,.:.�. k: ..,,:. . ..fY# 6r'rt .C.: . ,.. d.,... .:,. .,. r ';••m'. % 4} Yt f ut ns" c k, ius . •... a..�x r -. lllliat,.. .xr. . ". .t.,yy��<r�.,.,. . r • ,3i. . ,. ."y „'P< ;4.' ....} $$ 3 , )� ,,'..v. . . aYY %, i �`w+r �r�. ,,,. , 4 £� �,`ri arwar+, h„ .YTS��,5.��ean � ",7 a �dv ra:a r a hit .s 'gr�g:r Yti, ,` o- r;;,a yz . „ �,> „ rt.o-.j `, YSs' R Y# ' ., ',r{'�.r., ¢,. . ,,m.,.t: ..,.,..,.,. 8r . f4 ' r.y,1. m.',";:.. . t:pp>.2. .. t ,. t ••t " •. ,, a. r➢",'r� 5 • Y.r s. r, t'}: is wa,. .r, a 'i�i:,t „'i'. :, r..�.,t.„ :. c :a 4 „ •:'y :x sr 4 u a :> §r .. ;. '.; Y ,. ,h: .. ,cd „r k, ,,, w w*., a' r,w •> , sry J kg'.. a Y. r ?,,,, ..•4� ,: , :�' ..,. .�Y a ,F,,. l Y '` .'' ;�`° r, ,! ......A, .a..., .v .. ._ u.r .. ,.. ,W .rr'n .,Y;, c , .,., ..• t ., ,, ., x:.e , ,roitw 1, r ,.. .t ¢.: x yy '1" ,,>>, �K ,, ....r., .. <.. ,.«.E°Q ua Y, .,r 3���t�a.,��,.'h.ri, : F, . ,U. .,{l.•e., t.4..r�,i' 'er,• L rbr ay ?T 7s4...'`�ry�., �, r: r., t�atE,.r Sx ,2 ":�32iF..dou ITEM MANUFACTURER SPECIFICATION Color Source DESCRIPTION LOCATION NOTE FLAMIBILffY PT1 Wolf gordon Scuffmaster tough white collection G 7115707 steven kom (800) 347-0550 X 886 provided by G.C. specialty PAINT walls 9 DAY LEAD TIME class A ASTM E -84-91a PT2 BENJAMIN MOORE SUPER SPEC GREEN SPEC ZERO V.O.C. LATEX PAINT super white Anna Lehman, (786) 256-0794 BENJAMIN MOORE FLAT PAINT CEILINGS CLASS A WC1 Maya Romanoff stiched vertical MR -SV -X-15-0 provided by owner 30" wide wallcovering not used NOT USED Bass A ASTM E-84 WC2 Maya Romanoff stiched II type vinyl metalic white provided by owner 20 oz. 54" wide wallcovering wall & valance class A ASTM E-84 WC3 NOT USED N/A WC4 Canegie Fabrics Xorel Damask emboss 6635 paper backed w138 provided by owner 52" wallcovering columns Bass A ASTM E-84 wcs Eykon Wallcovering Brio ,Canton A119-524 provided by owner 54" Type II wallcovering walls class A ASTM E-84 DF2 Knoll Textiles chic silverlight provided by owner 54" fabric drapery treated by American Flamecoat to pass NFPA 701 B1 Johnsonite MW -66-A 66 -either ore provided by G.C. 4.5" wall base front of house walls class A ASTM E-84 B2 Johnsonite wall base vinyl 20- charcoal provided by G.C. 4" wall base back of house walls class A ASTM E-84 C1 Constantine sandal C469108 broadloom carpet r� 108 granite shadow provided by owner 12' bolt broadloom fitting areas CLASS I, ASTM E 648-06, NFPA 253 C2 Chilewich Contract BASKETWEAVE PLATINUM provided byowner 56" ROLL cash wrap CLASS I, ASTM E 648-06, NFPA 254 C2a ENCORE INTERNATIONAL UNDERLAYMENT QTSCU provided by G.C. cash wrap CLASS I, ASTM E 648-06, NFPA 254 T1 Porcelanosa estaurario blanco p14590481 G -P061 blanco /gloss finish provided by owner 24"x 24" x 1/2" thick porcelain tile sales area C.O.F..Grout Latricrete #88 Color. Silver Shadow N/A T2 Design Works Iris us, Brush Stroke Walnut Stroke V2 provided by owner 12" x 24" x 1/2 thick porcelain tile sales area entry C.O.F. Grout : Laticrete #35 Color. Mocha N/A VT1 Armstong Imperial texture standard Excelon 51941 polar white provided by G.C. 12" x12" VCT back of house areas CLASS A PL1 Formica color core 7223o-90, polished finish 7223o-90 provided by owner cash wrap CLASS A MTL1 satin stainless steel #4 metal finish N/A MTL2 buffed bronze metal finish N/A MTL3 Stylmark #110304 w/ base #410443 natural buffed alum. provided by owner metal end cap, 2-1/4" wide extruded aluminum endcap. from 1/2" AFF to underside of drywall at 7'-6" N/A MTL4 Kawneer Permanodic anodized finishes dark bronze No. 40 dark bronze No. 40 provided by G.C. AA-M12C22A44 Storefront CLASS A VV1 6" wide MDF trim w/ plywood blocking painted to match PL1 finish provided by millworker, installed by G.C. PLYWOOD TO BE FIRE TREATED CLASS A ACT1 Armstrong #895 minaboard / firegaurd fissured white provided by G.C. 24"x48x 5/8" lay -In panels, with white Tee grid suspension system back of house Fire rated UL label 1 hour 6.5.2013 SOUTHCENTER MALL SPACE #640 RECEIVED CITY T Y OF TUKWILA JUN 19 2013 PERMIT CENTER REVISIONS ..iEGISTERED '',l CIIITECT COIT T ! AN1D MORGAN , Ta111 Of AASHIVGIC INTERIOR ELEVATIONS & FINISH SCHEDULE SHEET NUMBER DATE: 3.26.2013 JOB NO: DRAWN: CHECKED: 711 • N. FiEL.DER • l D. ARLINGTON,••• TX '7.60)17 F11: (817). 631 )7.5696 FAX:. (817) 635-:..5602 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 132013 City of Tu ila BUILDING VISION SOUTHCENTER MALL TUKWILA, WA COVER SHEET GENERAL NOTES SPECIFIC NOTES / DEMOLITION PLAN P: TITION PLAN / RESPONSIBILITY SCHEDULE LEGEND CAP TOILET REQMTS. +RING DETAILS & SCHEDULE / FIXTURE INDEX ID -4a REFLECTED CEILING PLAN ID -5 STOREFRONT ELEVATION / DETAILS ID -6 DETAILS ID -7 ELEVATIONS ID -8 SECTIONS & DETAILS E-1 POWER & SIGNAL PLAN / LEGEND E-2 REFLECTED CEILING ; PLAN ' / LEGEND. E-3 ELECTRICAL SPECIFICATIONS PANEL SCHEDULE / RISER DIAGRAM M-1 HVAC / FIRE SPRINKLER / PLUMBING SP -1 FIRE SPRINKLER FSE CENTER: LANDLORD CONTACT: DATA: WESTFIELD SOUTHCENTER 2800 SOUTHCENTER SEATTLE, WA 98188 WAYNE JOHNSON CELL 206-714-3485 WJOH N SON ®WESTFI ELD. COM Elizabeth Vernengo / Regional Project Coordinator - Northwest I Tenant Coordination 835 Market Street I Suite 850 I San Francisco, CA 94103 T 415 268.8318 I F 310.775.4364 I C 209.969.1020 ovsrn iigo(i.tm stiiairl.corn TENANT: CACHE - SPACE 640, LEVEL 1 SCOPE OF WORK: TENANT IMPROVEMENT / INTERIOR BUILD OUT MAXIMUM NUMBER OF EMPLOYEES AT ANY ONE TIME NOT TO EXCEED 3 EMPLOYEES. BUILDING CONSTRUCTION TYPE: 2B, 1 HR FULLY SPRINKLERED DATA: OCCUPANCY GROUP: M DESCRIPTION: ENCLOSED MULTI -STORY MALL BUILDING AREA: SELLING AREA 1555 S/F NON SELLING AREA 558 S/F TOTAL GROSS AREA 2113 S/F (SALES AREA)+ (NON—SALES) (CODE SQ. FT.) (CODE SQ. FT.) 1555 + 558 = 52+2 =5_4 40 300 TOTAL — OCCUPANCY LOAD APPLICABLE CODES: • 2009 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS • 2011 NATIONAL ELECTRIC CODE • 2009 INTERNATIONAL MECHANICAL CODE • 2009 UNIFORM PLUMBING CODE • ` .299#7 ANSI ACCESSIBILITY: FEDERAL ADA REQUIREMENTS AND THE ACCESSIBILITY REQUIREMENTS NOTED IN CHAPTER 11 OF THE INTERNATIONAL BUILDING CODE WITH ITS REFERENCED ANSI A117.1 MRA ph: 305.592.0040 fax: 305.592.5144 email: infoOmradesign.com CACHE Affn: Clifford Gray ph:(212) 575-3268 fax:(212)764-2129 email: cgrayOcache.com it I. II II II II II II II II II II II I I II .I I 11 11 11 1 .1_ 11 11 II II 11 I I I■ 111:1;,a ..�r. ...... i I,'.; 1 KEYPL:el` NOT TO SCALE SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION' REVISED PERMIT SET 5.01.2013 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No. girl 2Z Plan review approval is subject to errors and omissions. Approval of construction documents does net au hc 1z3 the tion of any adopted code or ordinance. R3ceipt of approved Field Copy and conditions is tlpsd. '2A By City Of 1lskwita BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 062013 PERMIT CENTER INCOMPLETE L. 77,71",17,7,' 4.30.2013 RV' _\ I`,Ir 1.8897 CORTLAND MORGAN STATE OF WASHINGTON I IFF:1 GENERAL NOTES 1. THE GENERAL CONTRACTOR AND ALL SUB -CONTRACTORS ARE REQUIRED TO CHECK AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AT BUILDING SITE AND PREMISES AND NOTIFY MICHAEL ROSENTHAL ASSOCIATES OF ANY AND ALL DISCREPANCIES BEFORE STARTING ANY WORK. 2. ALL WORK ON THIS PROJECT SHALL BE IN ACCORDANCE WITH ALL CODES, SUB -CODES. AND BUILDING DEPARTMENTS HAVING JURISDICTION. GENERAL CONTRACTOR TO CONTACT LOCAL BUILDING OFFICIALS FOR SPECIFIC REQUIREMENTS FOR THIS RETAIL USE. 3. THE OCCUPANCY CLASS FOR THIS LOCATION IS CLASSIFIED AS "MERCHANTILE 4. THE GENERAL CONTRACTOR AND THE SUB -CONTRACTORS FOR THE GENERAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL PERMITS REQUIRED FOR THE WORK NOTED ON THESE PLANS AND SPECIFICATIONS. THIS INCLUDES COSTS FOR ALL INSPECTIONS BY AUTHORITIES HAVING JURISDICTION, BUILDING DEPARTMENT PERMIT COSTS, AND PERMIT COSTS FOR FIXTURING SUPPUED BY OWNER (IF APPUCABLE). 25. ANY SUBSTITUTIONS OF FINISH MATERIALS MUST BE APPROVED BY MICHAEL ROSENTHAL ASSOCIATES IN WRITING. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SUBMITTING TWO (2) SAMPLES OF EACH SUBSTITUTION. 26. ALL CONCRETE INF1LLS MUST HAVE .15 MIL VAPORBLOCK VAPOR BARRIER WITH 6" SEAM OVERLAP SEALED WITH VAPORBLOCK TAPE AND DOWEL #4 REBAR EVERY 18" 'OC INTO SURROUNDING SLAB. MUST BE INSPECTED BY ON-SITE LANDLORD REPRESENTATIVE AND BD PRIOR TO POUR. MAY ONLY BE CORE -DRILLED. IF TENANT IS ON UPPER LEVEL, THE RESPONSIBILITY, COSTS, AND COORDINATION OF WORKING IN A SPACE BELOW TENANTS SPACE FOR ELECTRICAL AND PLUMBING WORK, WILL BE BORNE BY THE GENERAL CONTRACTOR. 27. THE GENERAL CONTRACTOR AND ALL SUB -CONTRACTORS ARE TO FAMILIARIZE THEMSELVES WITH THE WORK TO BE PERFORMED BY THE LANDLORD AND BY THE TENANT AS PART OF THE EXECUTED LEASE AGREEMENT AND ANY AND ALL DESIGN CRITERIA. ANY DISCREPANCY BETWEEN THESE DRAWINGS AND THE LEASE OR DESIGN CRITERIA INFORMATION IS TO BE REPORTED TO MICHAEL ROSENTHAL ASSOCIATES PRIOR TO THE START OF ANY WORK. 5. ALL WORK SHALL CONFORM WITH THE LANDLORD'S DESIGN CRITERIA SUPPUED BY THE LANDLORD AND MADE PART OF THE TENANT'S LEASE. THE GENERAL CONTRACTOR IS TO OBTAIN A COPY OF THE DESIGN CRITERIA FROM THE TENANT AND THE REQUIREMENTS INCORPORATED IN THE CRITERIA FOR THE GENERAL CONTRACTOR AND SUB -CONTRACTORS WILL BE PART OF THE BIDS BY NE CONTRACTORS. 6. ALL CONTRACTORS SHALL CHECK AND VERIFY ALL FIELD CONDITIONS AND SHALL HAVE SOLE RESPONSIBILITY FOR VERIFICATION OF CLEAR HEIGHTS WITHIN THE PREMISES. ANY DISCREPANCIES SHALL BE REPORTED TO MICHAEL ROSENTHAL ASSOCIATES IMMEDIATELY. THE GENERAL CONTRACTOR IS TOTALLY RESPONSIBLE FOR ALL "HOLD" DIMENSIONS AND IS TO CONTACT MICHAEL ROSENTHAL ASSOCIATES FIRST, PRIOR TO BUILDING WALLS. IF THERE IS A QUESTION. TENANTS FIXTURES FIT INTO PLACE WIN NO ROOM FOR ERROR. 7. ALL CLEARANCES OF PIPES AND DUCT WORK INSTALLED BY THE GENERAL CONTRACTOR OR SUB -CONTRACTORS MUST BE MAINTAINED FOR ADEQUATE HEIGHTS REQUIRED FOR CEILING SYSTEM AND UGHT FIXTURES. THE STOCK ROOM CEILING IF REQUIRED, SHOULD BE AS HIGH AS POSSIBLE AND WITHIN CODE REQUIREMENTS. ALL WORK BY TENANT UNLESS OTHERWISE SPECIFIED IN TENANTS EXECUTED LEASE. 8. THE TENANTS GENERAL CONTRACTOR SHALL LAY OUT WORK AS SPECIFIED IN THE DRAWINGS AND SHALL BE HELD RESPONSIBLE FOR PROPER ESTABLISHMENT AND MAINTENANCE OF ALL LINES AND DIMENSIONS. BEFORE DOING ANY WORK, TENANTS GENERAL CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AND CONDITIONS AT THE SITE, SPEOFICALLY REGARDING TENANTS CASE FIXTURE LAYOUT AND EXACT PLACEMENT AND NOTIFY MICHAEL ROSENTHAL ASSOCIATES OF ANY DISCREPANCIES VERBALLY AND THEN IN WRITITNG. 9. ALL CONTRACTORS SHALL BE BONDABLE, LICENSED CONTRACTORS POSSESSING GOOD LABOR RELATIONS AND MUST BE CAPABLE OF QUALITY WORKMANSHIP, IN HARMONY WITH OTHER CONTRACTORS WORKING ON NE PROJECT. THE LANDLORD'S TENANT COORDINATOR FOR THE BUILDING IS TO BE NOTIFIED OF THE NAMES OF ALL SUB -CONTRACTORS PRIOR TO STARTING WORK - SUCH NOTIFICATION IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 10. PRIOR TO COMMENCEMENT OF ANY WORK, THE GENERAL CONTRACTOR SHALL CONTACT AND MEET THE LANDLORD'S FIELD REPRESENTATIVE FOR A PRE CONSTRUCTION MEETING AT WHICH TIME, HE WILL PRESENT A LIST OF NAMES, ADDRESSES, BUSINESS, AND HOME TELEPHONE NUMBERS OF THE SUB- CONTRACTORS FOR THIS PROJECT. 11. THE GENERAL CONTRACTOR AND ALL SUB -CONTRACTORS SHALL COMPLY WIN ALL THE PROVISIONS OF O.S.H.A. (OCCUPATIONAL SAFETY AND HEALTH ACT). 12. THE GENERAL CONTRACTOR SHALL HAVE AT ALL TIMES, AT THE PREMISES, "FINAL" LANDLORD APPROVED WORKING DRAWINGS AND BUILDING DEPARTMENT APPROVED PERMIT DRAWINGS. TENANT ARCHITECT TO ENSURE THAT ALL LANDLORD COMMENTS NOT INCLUDED IN BID PACKAGE SENT PRIOR TO LANDLORD APPROVAL ARE COMMUNICATED TO ALL SUBCONTRACTORS. ALL LANDLORD NOTES AND COMMENTS MUST APPEAR ON FINAL WORKING DRAWINGS IN THE FIELD. TENANT CONTRACTOR MUST MAINTAIN A LANDLORD APPROVED SET ON-SITE AT ALL TIMES. 28. ANY SCAFFOLDING, SAFETY RAILINGS, BARRICADES, AND/OR PROTECTION DEVICE REQUIRED FOR THE PROJECT WILL BE FURNISHED AND PAID FOR BY THE GENERAL CONTRACTOR AS PART OF THE BASE BID. IF NOT EXISTING: TENANT GC SHALL PROVIDE TEMPORARY CONSTRUCTION BARRICADE PRIOR TO COMMENCEMENT OF CONSTRUCTION PER DIRECTION OF LOCAL GENERAL GROWTH AUTHORITY. DO NOT FASTEN TO EXISTING MALL FINISH 29. PROTECTION OF WORK IN WORK PLACE- WORK IN PLACE THAT IS SUBJECT TO INJURY BECAUSE OF OPERATIONS BEING CARRIED ON ADJACENT THERETO SHALL BE COVERED, BOARDED UP, OR SUBSTANTIALLY ENCLOSED WITH ADEQUATE PROTECTION. ALL FORMS OF PROTECTION SHALL BE CONSTRUCTED IN A MANNER SUCH THAT, UPON COMPLETION, THE ENTIRE WORK WILL BE DELIVERED TO THE OWNER IN PROPER, WHOLE, AND UNBLEMISHED CONDITION. ALL SUCH WORK SHALL BE COORDINATED WITH THE LANDLORD'S REPRESENTATIVE. 30. THE STRUCTURAL SYSTEM OF THE SHOPPING CENTER HAS BEEN DESIGNATED TO CARRY A MAXIMUM LIVE LOAD AS SPECIFIED IN THE LANDLORD'S CRITERIA. LOADING IMPOSED BY ANY OF THE TENANTS WORK ON A TEMPORARY OR PERMANENT BASIS SHALL NOT EXCEED SUCH SPECIFIED LOAD. 31. ANY ALTERATIONS, ADDITIONS,OR REINFORCEMENTS TO LANDLORD'S STRUCTURE TO ACCOMMODATE TENANTS WORK SHALL. NOT BE PERFORMED WITHOUT IN EACH INSTANCE TENANT OBTAINING LANDLORD'S PRIOR WRITTEN APPROVAL; AND THE GENERAL CONTRACTOR, IN PERFORMING THIS WORK, SHALL LEAVE LANDLORD'S STRUCTURE AS STRONG AS, OR STRONGER THAN, THE ORIGINAL DESIGN AND WITH FINISHES UNIMPAIRED. 32. THE TENANT SHALL APPLY FOR ALL UTILITY METERS. 33. SPRINKLER SYSTEM DESIGN AND LAYOUT TO BE PROVIDED BY SPRINKLER SUB- CONTRACTOR, AND ALL SUBMISSIONS TO THE FIRE MARSHALL AND BUILDING INSPECTOR FOR THE NECESSARY APPROVAL ARE THE RESPONSIBILITY OF NE SPRINKLER SUB -CONTRACTOR. SPRINKLER HEAD SPACING TO CONFORM WITH THE LATEST N.F.P.A. STANDARDS AND ALL CODES HAVING JURISDICTION. IF THE ARCHITECT INDICATES SPRINKLER HEAD LOCATIONS, THEN THESE SPRINKLER HEAD LOCATIONS ARE TO BE RELOCATED, MODIFIED, OR ADJUSTED AS REQUIRED, BASED ON TENANTS FLOOR LAYOUT AND REFLECTED CEILING PLANS. SHOP DRAWING SUBMITTAL AND APPROVAL TO THE LANDLORD AND ALL GOVERNING AGENCIES BY THE SPRINKLER SUB -CONTRACTOR. 13. THE GENERAL CONTRACTOR IS TO ARRANGE WITH THE LANDLORD FOR THE BUILDING, WHERE BUILDING EQUIPMENT AND MATERIALS ARE TO BE LOCATED AND HOW TRUCK TRAFFIC IS TO BE ROUTED TO AND FROM THE BUILDING. 14. AN APPROVAL BY THE LANDLORD WILL ONLY BE VALID IF IN WRITTING AND SIGNED BY THE LANDLORD OR BY THE LANDLORD'S DESIGNATED REPRESENTATIVE FOR SUCH PURPOSE. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING APPROVAL FROM LANDLORD ON ALL STRUCTURAL CHANGES DURING THE COURSE OF THE CONSTRUCTION PHASE OF PROJECT AS WELL AS VERIFICATION OF CORRECT INSTALLATION AND SPECIFICATION FOR MISCELLANEOUS STEEL FOR H.V.A.C., STEEL FOR MEZZANINES, DECKS, ETC. THE ELECTRICAL SUB -CONTRACTOR IS TO PROVIDE A CIRCUIT DIRECTORY WITH PROPER PHASING AND BALANCING, WHICH IS TO CONFORM TO THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE AND UNDERWRITER'S CODE. THE SIGN(S) JUNCTION BOX PERMIT IS TO BE INCLUDED IN THE WORK FOR THE ELECTRICAL SUB -CONTRACTOR AND THE BOX IS TO BE SUPPLIED BY THIS CONTRACTOR AND PROPERLY LABELED. HOOK-UP TO THE LIGHT SOURCE FOR THE SIGN BY THE ELECTRICAL SUB -CONTRACTOR. THE MECHANICAL SUB -CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE PRIOR TO SUBMITTING A BID FOR THE WORK ON THIS PROJECT. THE CONTRACTOR MUST FAMIUARIZE HIMSELF WITH THE FIELD CONDITIONS. ALL TOILET ROOM SHEETROCK TO BE WATER RESISTANT, FIRE -RETARDANT, IF REQUIRED, AND 5/8" THICK. 15. ALL FINISH AND EXPOSED WOOD SHALL BE KILN-DRIED,MILL QUALITY FINISH AND SHALL RECEIVE A FIRE RETARDANT COATING OR TREATMENT IF REQUIRED BY CODE OR LOCAL FIRE MARSHALL NO WOOD OR COMBUSTIBLE MATERIAL SHALL BE USED ABOVE THE SUSPENDED CEILING UNLESS NON-COMBUSTIBLE LUMBER IS USED AND IS SPECIFICALLY ALLOWED BY B.O.C.A., LOCAL BUILDING CODES, THE FIRE MARSHALL AND ALL AGENCIES HAVING JURISDICTION. IF FIRE TREATED WOOD IS REQUIRED FOR FIXTURING ITEMS, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR EXECUTING THIS WORK AS PER BUILDING OFFICIALS' REQUIREMENTS. 37. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL SUB- CONTRACTOR TO INSTALL ALL NECESSARY MISCELLANEOUS STRUCTURAL STEEL SHAPES TO BE INSTALLED WHERE DIRECTED BY THE. LANDLORD'S REPRESENTATIVE AND THE TYPE OF EQUIPMENT NECESSARY FOR TENANTS DEMISED PREMISES. 16. THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL, AS REQUIRED, HAND OPERATED FIRE EXTINGUISHERS U.L. RATED, AS PER LOCAL CODE REQUIREMENTS; PLACEMENT AS APPROVED BY TENANT. 17. ALL CEIUNGS, IF REQUIRED, SHALL BE UNDERWRITERS' APPROVED AND OF NE NON-COMBUSTIBLE TYPE. 18. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY REMOVAL, OR AS REQUIRED BY LANDLORD, OF TRASH, RUBBISH AND SURPLUS MATERIALS RESULTING FROM CONSTRUCTION. THE GENERAL CONTRACTOR MUST MAINTAIN A CLEAR PATH OF EGRESS FROM THE PREMISES FREE FROM TRASH AND RUBBISH AT ALL TIMES. ALL SHEETROCK TO BE 5/8" GYPSUM WALL BOARD, FIRE CODE "X BOTH SIDES. ALL METAL STUDS TO BE 3 5/8" METAL STUDS - 25 GA. OR AS PER CODE AT 16" O.C. TO UNDERSIDE OF DECK ABOVE UNLESS NOTED OTHERWISE. DEMISING WALL FIRE RATING TO BE DETERMINED BY GENERAL CONTRACTOR RESPONDING TO LANDLORD AND CODE REQUIREMENTS. ,ALL SHEETROCK TO BE APPLIED VERTICALLY ON WALLS UNLESS NOTED OTHERWISE. ALL SHEETROCK TO BE FIRE RESISTANT/NON-COMBUSTIBLE AS SPECIFIED BY LOCAL CODES. 40. ALL METAL FRAMING, SHEETROCK PARTITIONS, SOFFITS, AND FACADES BY THE GENERAL CONTRACTOR, UNLESS OTHERWISE NOTED. ALL SHEETROCK TO BE FIRETAPED AND SPACKLED THREE (3) COATS, SANDED TO A LEVEL 5 FINISH, AND READY TO RECEIVE PAINT AND WALLCOVERING. 42. THE GENERAL CONTRACTOR TO INSTALL SHEETROCK AND REQUIRED FIRE SAFING TO UNDERSIDE OF DECK ABOVE, AT DEMISING WALLS AND AT STOCK/SALES WALL WHERE REQUIRED. A COMPLETE SEPARATION BETWEEN THIS TENANT AND ALL ADJACENT TENANTS AND MALL IS TO BE PROVIDED. CONTRACTOR TO PACK DECK FLUTES WITH ROCKWOOL. ALL DOORS, DOOR FRAMES, TRIMMED OPENINGS, AND HARDWARE, INCLUDING LOCKS, TO BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS OTHERWISE NOTED. THE DOOR AND DOOR FRAME BETWEEN SALES AREA. AND STOCK ROOM TO BE HOLLOW METAL - "B" LABELED DOOR (UNLESS OTHERWISE NOTED ON DWGS.). 19. NE GENERAL CONTRACTOR SHALL FURNISH AND PAY FOR ALL TEMPORARY UTILITY SERVICES; IF SUCH COSTS ARE SPECIFICALLY NOTED IN THE LEASE TO BE PAID FOR BY THE TENANT, THE GENERAL CONTRACTOR IS NOT TO INCLUDE SUCH COSTS IN THE BID. 20. THE GENERAL CONTRACTOR SHALL IMMEDIATELY ORDER ALL LONG LEAD EQUIPMENT AND NOTIFY THE CLIENT IMMEDIATELY OF ANY PROBLEMS REGARDING AVAILABILITY OR DELIVERY AT THE BEGINING OF NE PROJECT. 21. THE GENERAL CONTRACTOR IS TO VERIFY ALL EQUIPMENT SPECIFICATIONS AND REQUIREMENTS WITH NE TENANT OR MICHAEL ROSENTHAL ASSOCIATES PRIOR TO NE START OF CONSTRUCTION. COORDINATION WITH THE ELECTRICAL SUBCONTRACTOR IS MANDATORY TO CAREFULLY CHECK ALL DRAWINGS AND VERIFY EQUIPMENT SELECTION AND CORRECT VOLTAGES. AMPERAGES, AND PHASING. NE GENERAL CONTRACTOR IS RESPONSIBLE TO CUT AND FRAME ALL OPENINGS FOR OTHER TRADES, SUCH AS MECHANICAL, PLUMBING, ELECTRICAL, THRU PARTITIONS AND STRUCTURAL WALLS. THE GENERAL CONTRACTOR AND ALL SUB -CONTRACTORS WORKING ON THIS PROJECT ARE RESPONSIBLE. FOR CONTACTING THE PUBLIC UTILITY COMPANIES SUPPLYING UTILITIES TO THE AREA, WHERE THE PROJECT IS LOCATED, IN ORDER TO VERIFY LOCATIONS OF UTILITIES, UNDERGROUND AND OVERHEAD, AND SECURE THE PROPER PROCEDURES WHILE WORKING ADJACENT TO, ABOVE, OR NEAR SUCH UTILITIES TO AVOID ANY PROBLEMS WITH EXPLOSIONS, DISCONNECTIONS, REMOVALS, ETC. 22. THE GENERAL CONTRACTOR AND/OR ELECTRICAL SUBCONTRACTOR IS TO INSTALL (OWNER SUPPUED) EMERGENCY AND EXIT LIGHTING, AS REQUIRED BY LOCAL CODE OR AGENCIES HAVING JURISDICTION OVER THE PROJECT. THE EXIT/EMERGENCY LIGHTING SHOULD BE PROPERLY LABELED AND APPROVED TYPE LOCK -OUTS INSTALLED. 23. THE GENERAL CONTRACTOR SHALL SUPPLY ALL NECESSARY GROUNDS FOR MILLWORK AND FIXTURES, FITTINGS, AND EQUIPMENT REQUIRED. 24. ALL STOREFRONT AND INTERIOR GLAZING MUST COMPLY WITH ALL APPUCABLE CODES, LANDLORD'S CRITERIA, TENANTS DRAWINGS AND SAFETY GLAZING STANDARDS. WHEN BIDDING THIS PROJECT, EACH CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE SITE PRIOR TO BIDDING AND VERIFYING EXISTING CONDITIONS AS REFLECTED IN THESE CONTRACT DOCUMENTS. ANY EXTRA WORK REQUIRED BUT NOT INCLUDED IN THE DOCUMENTS SHALL BE REPORTED IMMEDIATELY TO MICHAEL ROSENTHAL ASSOCIATES. 47. THE GENERAL CONTRACTOR IS REQUIRED TO FAMILIARIZE ALL PERSONS AND SUB -CONTRACTORS WORKING ON THIS PROJECT WITH THESE GENERAL NOTES AND THE CONTRACT DOCUMENTS NOTED IN THESE DRAWINGS, LANDLORD'S DESIGN CRITERIA, AND THE EXECUTED LEASE AGREEMENT BETWEEN LANDLORD AND TENANT. THE TENANTS GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FULLY ACQUAINTING HIMSELF WITH THE CONTENTS AND SCOPE OF THESE SPECIFICATIONS, AND SPECIAL ATTENTION SHOULD BE GIVEN THE SPECIFICATIONS THROUGHOUT THE SPAN OF THIS PROJECT BY THE TENANTS GENERAL CONTRACTORS, SUPERVISORS, AND SUB -CONTRACTORS, AS NE STANDARD ESTABLISHED HEREIN SHALL BE APPUED, WITH EMPHASIS TO ALL WORK. WORK DECLARED UNACCEPTABLE BY THE OWNER SHALL BE CORRECTED IN A MANNER AND TO A DEGREE OF QUALITY AS ACCEPTABLE BY THE OWNER. 48. TENANTS GENERAL CONTRACTOR AND ALL SUB -CONTRACTORS ARE REQUIRED TO FURNISH THE FOLLOWING MINIMUM COVERAGE AND LIMITS OF LIABILITY. IF LANDLORD'S REQUIREMENT(S) ARE MORE NUMEROUS IN TYPE OF COVERAGE OR MORE STRINGENT, THE GENERAL CONTRACTOR IS REQUIRED TO ADHERE TO NE ADDITIONAL REQUIREMENTS AND THE MOST STRINGENT OF THESE REQUIREMENTS. A. WORKMAN'S COMPENSATION, AS REQUIRED BY STATE LAW, AND INCLUDING EMPLOYER'S LIABILITY INSURANCE WITH A LIMIT OF NOT LESS THAN $2,000,000 AND ANY INSURANCE REQUIRED BY ANY EMPLOYEE BENEFITS ACT OR OTHER STATUTES APPLICABLE WHERE NE WORK IS TO BE PERFORMED AS WILL PROTECT NE CONTRACTOR AND SUB -CONTRACTORS FROM ANY AND ALL LIABILITY UNDER THE AFOREMENTIONED ACTS. B. COMPREHENSIVE GENERAL LIABILITY INSURANCE (INCLUDING CONTRACTOR'S PROTECTIVE LIABIUTY) IN AN AMOUNT NOT LESS THAN $2,000,000 FOR ANY ONE OCCURANCE WHETHER INVOLVING BODILY INJURY LIABILITY (OR DEAN RESULTING THEREFROM) OR PROPERTY DAMAGE LIABILITY OR A COMBINATION THEREOF WITH A AGGREGATE LIMIT OF $2,000,000. SUCH INSURANCE SHALL PROVIDE FOR EXPLOSION, COLLAPSE, AND UNDERGROUND COVERAGE. SUCH INSURANCE SHALL INSURE TENANT'S GENERAL CONTRACTOR AGAINST ANY AND ALL CLAIMS FOR BODILY INJURY, INCLUDING DEATH RESULTING THERE FROM AND DAMAGE TO ON DESTRUCTION OF PROPERTY OF ANY KIND WHATSOEVER AND TO WHOMEVER BELONGING AND ARISING FROM HIS OPERATIONS UNDER THE CONTRACT AND WHETHER SUCH OPERATIONS ARE PERFORMED BY TENANTS GENERAL CONTRACTOR, SUB- CONTRACTORS, OR ANY OF THEIR SUB -CONTRACTORS, OR BY ANYONE DIRECTLY OR INDIRECTLY EMPLOYED BY ANY OF THEM. GENERAL CONTRACTOR'S PROTECTIVE LIABILITY INSURANCE GENERAL CONTRACTOR SHALL PROVIDE OWNER'S PROTECTIVE LIABILITY INSURANCE AS WILL INSURE GENERAL CONTRACTOR AGAINST ANY AND ALL LIABILITY TO THIRD PARTIES FOR DAMAGE BECAUSE OF BODILY INJURY LIABIUTY (OR DEATH RESULTING THEREFROM) AND PROPERTY DAMAGE LIABILITY OF OTHERS OF A COMBINATION THEREOF WHICH MAY ARISE FROM WORK IN CONNECTION WITH THE LEASED PREMISES, AND ANY OTHER LIABILITY FOR DAMAGES WHICH THE TENANT'S GENERAL CONTRACTOR AND/OR SUB -CONTRACTORS ARE REQUIRED TO INSURE AGAINST UNDER ANY PROVISIONS HEREIN. SAID INSURANCE SHALL BE PROVIDED IN MINIMUM AMOUNTS AS FOLLOWS: A. BODILY INJURY, PER OCCURRENCE FOR PERSONAL INJURY AND/OR DEATH B. PROPERTY DAMAGE LIABILITY $5,000,000 GENERAL CONTRACTOR'S BUILDERS RISK INSURANCE- COMPLETED VALUE BUILDERS RISK MATERIAL DAMAGE INSURANCE COVERAGE. GENERAL CONTRACTOR SHALL PROVIDE AN "ALL PHYSICAL LOSS" BUILDERS RISK INSURANCE POLICY ON THE WORK TO BE PERFORMED FOR TENANT IN THE LEASED PREMISES AS IT RELATES TO THE BUILDING WITHIN WHICH THE LEASE PREMISES IS LOCATED. THE POLICY SHALL INCLUDE AS INSURED, TENANT, TENANT'S ARCHITECT, MICHAEL ROSENTHAL ASSOCIATES (IF APPLICABLE), ITS CONTRACTOR AND SUB -CONTRACTORS, THE LANDLORD, AS THEIR INTERESTS MAY APPEAR. THE AMOUNT OF INSURANCE TO BE PROVIDED SHALL BE 100% OF THE REPLACEMENT COSTS. THE GENERAL CONTRACTOR IS REQUIRED TO UST ALL ADDITIONAL INSUREDS AS PER LANDLORD'S CRITERIA IN ADDITION TO MICHAEL ROSENTHAL ASSOCIATES AND TENANTS ARCHITECT. INSURANCE REQUIREMENTS NOT OBTAINED BY THE GENERAL CONTRACTOR, AS NOTED ON NE DRAWINGS AND IN THESE SPECIFICATIONS WILL NOT RELIEVE THE GENERAL CONTRACTOR OF THE RESPONSIBILITY OF UABILITY(S) FOR THIS PROJECT. A COPY OF ALL INSURANCE PAPERS ARE TO BE SENT DIRECTLY TO THE TENANT, NOT ONLY FOR REVIEW BUT FOR RECORD PURPOSES. 49. NE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION -DOCUMENT A-201, ISSUED BY THE AMERICAN INSTITUTE OF ARCHITECTS, 1981 EDITION RELATES TO THE WORK OF THIS PROJECT AND IS HEREBY MADE A PART OF THESE DRAWINGS AS THOUGH FULLY CONTAINED IN THESE DRAWINGS. THE OWNER WILL UTILIZE A.I.A. DOCUMENT A-107 "STANDARD FORM OF AGREEMENT" BETWEEN OWNER AND CONTRACTOR AS THE CONTRACT DOCUMENT. 50. THE TENANTS GENERAL CONTRACTOR AND ALL SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR OBTAINING THE NECESSARY NUMBER OF COPIES OF DOCUMENT A-201, TO ACQUAINT HIMSELF WITH THE ARTICLES CONTAINED THEREIN AND TO REVIEW WITH ALL SUB -CONTRACTORS, SUPPLIERS, AND ANY OTHER PARTIES TO THE CONTRACT OR INDIVIDUALS OR AGENCIES ENGAGED ON THE WORK AS TO ITS CONTENTS. 51. THE TENANT AND MICHAEL ROSENTHAL ASSOCIATES, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK, ALTER, ADD TO, OR DEDUCT FROM THE CONTRACT WORK. THE CONTRACT SUM SHALL BE ADJUSTED ACCORDINGLY AND SUCH COSTS SHALL BE COMPETITIVE WITH LOCAL CONSTRUCTION COSTS. 52. GUARANTEES FOR ALL WORK BY SUB -CONTRACTORS SHALL BE FOR A PERIOD OF ONE YEAR, UNLESS OTHERWISE NOTED. AT THE TIME OF FINAL SUBMITTAL FOR ALL COSTS, INCLUDING BASE BID, EXTRAS, AND CREDITS, THE SUB- CONTRACTORS SHALL FURNISH TO THE GENERAL CONTRACTOR A WRITTEN GUARANTEE STIPULATING THAT, AT NO ADDITIONAL COST TO THE GENERAL CONTRACTOR OR TENANT, ANY DEFECTIVE WORK OR MATERIALS SHALL BE REPAIRED OR REPLACED FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF WORK, UNLESS OTHERWISE NOTED. IF SUCH WORK AFFECTS LANDLORD'S WORK, LANDLORD'S WORK IS TO BE COMPLETED BY THE SUB -CONTRACTOR AT NO COST TO THE TENANT. 53. ALL PAYMENTS MADE TO THE GENERAL CONTRACTOR FOR THIS PROJECT ARE TO BE ALLOCATED FOR THIS PROJECT ONLY FOR PAYMENTS TO SUB -CONTRACTORS, MATERIAL SUPPLIERS, AND AGENTS AUTHORIZED BY THIS CONTRACT TO PERFORM WORK OR SUPPLY MATERIALS TO THIS PROJECT ONLY. THE GENERAL CONTRACTOR IS REQUIRED TO SUBMIT PARTIAL WAIVERS OR LIENS FOR HIS WORK AS WELL AS SUB -CONTRACTORS OR MATERIAL SUPPLIERS, UPON REQUEST OF THE CLIENT OR CLIENTS ARCHITECT AND THE REQUEST FOR NE FINAL 10% RETENTION ON THIS PROJECT MUST INCLUDE SIGNED AND EXECUTED WAIVERS OF LIEN INDICATING 100% COMPLETION AND 100% PAYMENT IN FULL, BY ALL SUB- CONTRACTORS AND MATERIAL SUPPLIERS. 54. NO EXTRAS FOR COSTS CAN BE AUTHORIZED UNLESS APPROVED BY THE ARCHITECT, THE PROJECT MANAGEMENT COMPANY FOR THE TENANT, OR THE TENANT. AN ISSUANCE OF CREDITS TO BE CACULATED BASED ON COMPETITIVE RATES AND EQUIPMENT COSTS APPROVED BY NE ARCHITECT, THE PROJECT MANAGEMENT COMPANY FOR THE TENANT, OR THE TENANT. 55. THE CONTRACTOR AGREES THAT IN PERFORMANCE OF THE WORK CALLED FOR BY THE CONTRACT, THEY WILL EMPLOY ONLY SUCH LABOR AS WILL NOT DELAY OR INTERFERE WITH THE PROGRESS OF THE PROJECT AND AS WILL BE ACCEPTABLE TO AND WORK IN HARMONY WITH ALL OTHER CONTRACTORS EMPLOYED ON NE CONSTRUCTION SITE OR ON ANY OTHER BUILDING, STRUCTURE, OR OTHER IMPROVEMENT WHETHER PUBLIC OR PRIVATE WHICH THE GENERAL CONTRACTOR MAY THEN BE ERECTING OR ALTERING IN OTHER LOCATIONS. 56. UPON COMPLETION OF WORK, THE GENERAL CONTRACTOR AND ALL SUB- CONTRACTORS ARE TO OBTAIN A CERTIFICATE OF COMPLETION AND APPROVAL FROM THE BUILDING DEPARTMENT, OR OTHER AUTHORITIES HAVING JURISDICTION, AND SUBMIT SAME TO THE TENANTS ARCHITECT. FINAL PAYMENT WILL NOT BE ISSUED PRIOR TO RECEIPT OF SUCH CERTIFICATE(S). 57. FOR CLARIFICATION PURPOSES. TENANT, CLIENT, AND OWNER ARE THE SAME PARTY, LANDLORD IS THE PARTY LEASING THE SPACE TO THE TENANT AND THE GENERAL CONTRACTOR WILL BE REQUIRED TO HANDLE ALL WORK IN THESE DOCUMENTS UNLESS SPECIFICALLY NOTED OTHERWISE. 58. THE GENERAL CONTRACTOR IS REQUIRED TO FURNISH AND INSTALL A REAR EXIT DOOR AND APPROVED TYPE DETEX PANIC BAR ASSEMBLY, PAINT OUTSIDE OF DOOR AS PER LANDLORD'S REQUIREMENTS. 59. THE GENERAL CONTRACTOR SHALL UNLOAD, PROTECT AND INSTALL (INSTALL ONLY IF NOTED TO DO SO), TENANT'S EQUIPMENT, FIXTURES, AND FURNISHINGS. 60. NE TENANTS DESIGN CONCEPT LEAVES ZERO OR MINIMAL CLEARANCE FOR ERROR IN REGARD TO FIXTURE LAYOUT. "HOLD DIMENSION" INDICATIONS ARE TO BE ADHERED TO AND THE CONTRACTOR IS TOTALLY RESPONSIBLE FOR ERROR OR OMISSION. ANY QUESTIONS RELATING TO DIMENSIONING ARE TO BE ADDRESSED TO MICHAEL ROSENTHAL ASSOCIATES ONLY. 61. THE FLOOR FINISHES, WITHIN THE PREMISES, OR AT THE TRANSITION BETWEEN LANDLORD FLOOR FINISHES AND TENANT'S FLOOR FINISHES (AT ENTRY OR REAR DOOR, IF APPLICABLE) ARE TO BE SMOOTH AND LEVEL TO AVOID TRIPPING HAZARDS AND BE WITHIN THE REQUIREMENTS OF BARRIER FREE DESIGN. 62. TOTAL CLEAN-UP: THE GENERAL CONTRACTOR IS TO PERFORM A TOTAL CLEAN-UP PRIOR TO TURNING SPACE OVER TO CACHE" FOR MERCHANDISING. THIS CLEAN-UP IS TO INCLUDE THE FOLLOWING ITEMS BUT NOT LIMITED TO: • CLEANING OF STOREFRONT GLASS AND DOORS • POLISHING OF STOREFRONT SIGN • WIPE DOWN AND CLEANING OF ALL WALL, SHOWCASE, AND LOOSE FIXTURING (INCLUDING MIRRORS, GLASS PANELS ON TOP OF CASEWORK, GLASS TOPS AND SHELVES WITHIN FIXTURES) • VACUUMING OF FITTING: ROOM CARPET • CLEAN & APPLY 2 COATS OF COMMERCIAL WAX TO VINYL FLOOR IN STOCK & TOILET ROOMS - ALL VINYL FLOORS MUST HAVE A "HOSPITAL SHINE". • PORCELAIN CERAMIC TILE FLOOR IN SALES AREA - VACUUM, LIGHTLY WASH WI VINEGAR & WATER. NE GENERAL CONTRACTOR IS TO FILL ALL WOODWORK NAIL HOLES AND JOINTS, TOUCH UP AS REQUIRED, AND COORDINATE ALL FINAL WORK REMAINING WITH ALL SUB -CONTRACTORS SO AS NOT IMPEDE "TOTAL CLEAN-UP BY GENERAL CONTRACTOR". THE GENERAL CONTRACTOR IS TO WIPE DOWN AND CLEAN CEILING 11LE AND GRID, CEILING UGHT FIXTURES. ADJUST ANGLE AND DIRECTION FOR ALL CEILING ACCENT LIGHT FIXTURES AND SHOW WINDOW TRACK LIGHT FIXTURES (ADJUSTMENTS TO BE MADE DURRING MERCHANDISING PRIOR TO STORE OPENING AS DIRECTED BY CACHE). 63. THE GENERAL CONTRACTOR IS REQUIRED TO HAVE ALL SUB -CONTRACTORS REVIEW THE ABOVE NOTES PRIOR TO BIDDING AND TO FOLLOW-UP AND EXECUTE AS WRITTEN. 64. THE GENERAL CONTRACTOR, CABINETRY CONTRACTOR, CACHE'S FLOORING CONTRACTOR, & CACHE'S SIGN CONTRACTOR WILL HAVE A MAXIMUM OF 30 DAYS TO COMPLETE ALL PUNCH LIST ITEMS TO CACHE'S SATISFACTION. AFTER THIS 30 DAY TIME PERIOD CACHE WILL TAKE STEPS TO COMPLETE ANY AND ALL OUTSTANDING PUNCH LIST ITEMS - BACK CHARGING ALL COSTS INVOLVED TO RESPECTIVE CONTRACTOR. 65. ALL WORK IS TO BE IN COMPLIANCE WITH ALL CURRENT CODES AND ORDINANCES. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 13 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 182013 PERMIT CENTER 3.26.2013 U SOUTHCENTER MALL SPACE 1640 C; O R T I_ ,A N D PSI O R (:i A N STATE OF WA,%:IHGTO(d GENERAL NOTES ID -1 SPECIFIC NOTES OFF-SITE PACKAGE: SUPPLIED BY CABINETRY CONTRACTOR RECEIVED BY GENERAL CONTRACTOR 1. GENERAL FIELD INSTALLED BY MILLWORK INSTALLER A. RUN CONTINUOUS AROUND FITTING ROOM PARTITIONS, MITER CUT INSIDE AND OUTSIDE CORNERS. INSTALL IN SALES AREA ONLY AS NOTED ON ELEVATIONS. 2. FITTING ROOMS A. FITTING ROOM PACKAGE BY CABINETRY CONTRACTOR TO INCLUDE: CASINGS & HARDWARE, FURNITURE 3. CASHWRAP AREA A. A METAL U CUP WITH ROD IS TO BE INSTALLED IN THE BACK CABINET FOR GIFTWRAP ROLL PAPER. B. ALL RECEPTACLES INCLUDING AN ISOLATED CIRCUIT ARE TO BE INSTALLED INSIDE THE BACK CABINET (BY GENERAL CONTRACTOR'S ELECTRICAL SUB -CONTRACTOR). C. HOLES ARE TO BE DRILLED AT EACH END OF THE REAR WALL COUNTER - (4) ON LH & (3) ON RH SIDE. BRUSHED CHROME FINISH GROMMETS WITH INSERTS ARE TO BE INSTALLED IN EACH HOLE AT THE CABINETRY SHOP. REFER TO CABINETRY SHOP DWGS. FOR HOLE LOCATIONS AND SIZE. D. THE 1/4" FABRIC PADS FOR ALL CABINETS WILL BE MADE UP AT THE CABINETRY SHOP. CABINETRY CONTRACTOR TO ORDER FABRIC FROM CACHE'S SUPPLIER. E. CACHE SUPPLIED GARMENT ARM TO BE INSTALLED ON COUNTERTOP OF REAR WALL COUNTER. LOCATION AS INDICATED ON CABINETRY SHOP DWGS. FIELD INSTALLED BY MILLWORK INSTALLER. 4. STANDARD MATERIALS TO BE USED A. SEE SCHEDULE 5. CABINETRY: SUPPLIED BY CABINETRY CONTRACTOR FIELD INSTALLED BY GC. A. RECEIVE AND INSTALL -ALL CABINET WORK, FINISHED MILLWORK, PANELING, DOORS, FRAMES, ETC. AS SHOWN ON DRAWINGS OR AS DIRECTED. B. CUT AND FIT ALL MILLWORK AND SET PLUMB AND TRUE. C. MITER CUT ALL INSIDE AND OUTSIDE CORNERS. D. SAND ALL SURFACES TO A SMOOTH AND EVEN FINISH. E. BACK OUT FLAT TRIM TO PREVENT WARPING. DRILL WHERE NECESSARY TO PREVENT SPLITTING. F. FIT ALL DOORS TO LEAVE EQUAL SPACE ON ALL SIDES, UNDERCUT. 6. CAULKING: SUPPLIED BY CABINETRY CONTRACTOR FIELD INSTALLED BY MILLWORK INSTALLER. A. CABINETRY CONTRACTOR TO PROVIDE A TOTAL OF (3) TUBES OF CAULKING FOR EACH STORE. (3) TUBES TO MATCH "BENJAMIN MOORE" PAINT COLOR LINEN WHITE PACKAGE: BY GENERAL CONTRACTOR CEILING SYSTEM 1. FURNISH AND INSTALL CEILING SYSTEMS COMPLETE WITH SUSPENSION SYSTEM AND RELATED ACCESSORIES AS SHOWN ON DRAWINGS AND AS SPECIFIED (SEE FINISH SCHEDULE). 2. SUSPENSION SYSTEM SHALL BE ADEQUATE TO SUPPORT LIGHT FIXTURES, CEILING GRILLES AND DIFFUSERS, AND OTHER NORMAL ACCESSORIES. PROVIDE SYSTEM COMPONENTS FROM SINGLE MANUFACTURER. 3. INSTALL CEILING AND SUSPENSION SYSTEM IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. FINISHED CEILING SHALL BE LEVEL, WITH JOINTS SNUG AND SQUARE, AND TILES OR PANELS IN PERFECT CONDITION. INSTALL SECURITY GRID CLIPS ON FIRST TWO TILES AROUND PERIMETER OF STORE. PAINTING, FINISHING, AND WALLCOVERING 1. THE INTENT IS TO PROVIDE A SATISFACTORY FINISH TO ALL PARTS OF THE PROJECT, WHETHER NOTED HEREIN OR NOT, UNLESS SPECIFICALLY STATED OTHERWISE. COVER ALL SURFACES THOROUGHLY, IF THE NUMBER OF COATS SPECIFIED DOES NOT ACCOMPLISH THE INTENT, THEN APPLY ADDITIONAL COATS OF SPECIFIED MATERIAL TO GIVE SATISFACTORY COVERAGE. SEE FINISH SCHEDULE. 2. USE ONLY THE PAINT AND RELATED MATERIALS OF THE MANUFACTURERS SPECIFIED. 3. CLEAN ALL SURFACES TO BE PAINTED FREE OF LOOSE DIRT AND DUST BEFORE WORK IS STARTED. 4. PAINTED DRYWALL TO RECEIVE ONE COAT LATEX PRIMER AND TWO COATS OF SPECIFIED PAINT. TINT PRIMER TO APPROXIMATE SHADE OF THE FINAL COAT. TOUCH UP ALL SUCTION SPOTS OR HOT SPOTS AFTER APPLICATION OF FIRST COAT AND BEFORE APPLYING SECOND COAT, TO PRODUCE AN EVEN RESULT IN THE FINISH COAT. DRY ALL COATS THOROUGHLY BEFORE APPLYING SUCCEEDING COATS. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR RECOAT TIME. SEAL ALL DRYWALL SURFACES BEHIND MIRRORS. 5. WASH ALL METAL SURFACES WITH MINERAL SPIRITS TO REMOVE ALL DIRT AND GREASE BEFORE APPLYING FINISH. WHERE RUST AND/OR SCALE IS PRESENT, WIRE BRUSH OR SAND CLEAN BEFORE APPLYING FINISH. 6. PUTTY ALL NAIL HOLES, COUNTERSUNK SCREWS, BOLTS, CRACKS, ETC., BEFORE APPLYING FINISH. 7. SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. 8. BEFORE STARTING FINISH WORK, REMOVE HARDWARE, ACCESSORIES, PLATES, LIGHTING FIXTURES, AND SIMILAR ITEMS, OR PROVIDE AMPLE PROTECTION FOR SUCH ITEMS. 9. WOOD DOORS: SEAL BOTTOMS, TOPS, AND EDGES. SAND ALL WOOD DOORS BEFORE FINISHING. 10. MAKE FINISH WORK UNIFORM OR APPROVED FINISH, SMOOTH, FREE OF RUNS, SAGS, AND DEFECTIVE BRUSHING AND CLOGGING. MAKE EDGES OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING. PORCELAIN CERAMIC FLOOR TILE (TILE, GROUT, 7 SEALER SUPPLIED BY CACHE - INSTALLATION BY G.C.) 1. PORCELAIN CERAMIC TILE AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. 2. INSTALL PORCELAIN CERAMIC TILE USING RECOMMENDED METHODS OF THE TILE CONTRACTORS ASSOCIATION OF AMERICA AND THE TILE COUNCIL OF AMERICA, INC. 3. INSTALL PORCELAIN CERAMIC TILE USING WHITE THIN -SET METHOD WITH PORTLAND CEMENT GROUTING MORTAR. JOINTS TO BE A MAXIMUM OF 1/16" IN WIDTH AND NOT BE IRREGULAR IN WIDTH. 4. CAREFULLY CLEAN ALL WORK AND REPLACE OR REPOINT ANY DAMAGED WORK AND LEAVE IN PERFECT CONDITION. USE NO ACID AGENT OR DEVICE THAT WILL MARK SURFACE. SUPPLY AND INSTALL FLOOR CARE PRODUCTS AS SPECIFIED IN FINISH SCHEDULE. 5. TILE GROUT LINES ARE NOT TO EXCEED 1/16" IN WIDTH. CARPET (SUPPLIED BY CACHE - INSTALLATION BY G.C.) 1. DIRECT GLUE DOWN CARPET INSTALLATION. INSTALL AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. 2. FILL ALL CRACKS, JOINTS, ETC. IN SUB -FLOOR WITH CRACK FILLER APPROVED BY CARPET MANUFACTURER. 3. PROVIDE BINDER BAR/EDGE STRIPS AT EXPOSED CARPET EDGES ONLY. DO NOT INSTALL BINDER BAR WHERE CARPETS ABUTT AT ADJACENT WOOD, MARBLE, OR CERAMIC TILE FLOORING. REINFORCED VINYL FLOOR TILE 1. FURNISH & INSTALL AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. 2. 1/8" x 12" x 12" REINFORCED VINYL TILES WITH 4" HIGH x 1/8" THICK, TOPSET, COVED VINYL BASE. SEE FINISH SCHEDULE. 3. FILL ALL CRACKS, JOINTS, ETC. IN SUB -FLOOR WITH CRACK FILLER APPROVED BY FLOORING MANUFACTURER. INSTALL ALL MATERIALS WITH WATERPROOF TYPE ADHESIVES AS RECOMMENDED BY FLOORING MANUFACTURER FOR MATERIALS AND SURFACES INVOLVED. SALES & FITTING AREA WALL BASE 1. FURNISH & INSTALL A 4 1/4" HIGH MILLED WALL BASE AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1 3 2013 City of Tukwila BUILDING DIVISION RESPONSIBILITY SCHEDULE ALL ITEMS MUST BE COMPLETED PRIOR TO COMMENCING CONSTRUCTION ITEM DESCRIPTION CACHE GENERAL CONTRACTOR REMARKS 1 DEMOLITION 2 Z 2 MALL FLOORING XY PURCHASE FROM LL OR LL'S SUPPLIER 3 DEMISING PARTITIONS- METAL STUDS VERIFY QUANTITIES OF WALLCOVERINGS REQUIRED XY IF NOT EXISTING 4 DEMISING PARTITIONS- GYPSUM BOARD XY TAPE, SPACKLE & PREPARE FOR NEW FINISHES 5 ELECTRICAL WORK- LIGHT FIXTURES WITH LAMPS SUPPLIED BY CACHE XY INCLUDE INTERCONNECTION & FINAL HOOK-UP OF CAB. CONTRACTOR LIGHT FIXTURES 6 SPEAKERS AND SOUND SYSTEM X Y 7 H.V.A.C. WORK XY 8 PLUMBING WORK XY 9 FIRE SPRINKLER WORK XY 10 STOREFRONT CONSTRUCTION XY AS NOTED ON DRAWINGS 11 STOREFRONT MATERIALS ' XY 12 STOREFRONT & INTERIOR SIGNING XY BY CACHE'S SIGN CONTRACTOR 13 GYPSUM BOARD CEILINGS & TRACK LIGHT POCKET XY TAPED, SPACKLED AND PRIMED 14 ACOUSTIC LAY -IN TILE CEILINGS XY STORAGE ROOM & REAR EGRESS ONLY 15 GYPSUM BOARD PART'NS, FURRING, ENCLOSURES XY TAPED, SPACKLED AND PRIMED 16 PAINTING OF GYPSUM BOARD CEILINGS & PART'NS XY 17 DOORS COMPLETE WITH HARDWARE XY EXCEPT AS NOTED ON DWG # ID -3 18 FITTING ROOM DRAPERY XY AS NOTED ON DVVG # ID -3 19 LAMINATE DOOR FACING X Y AS NOTED ON DWG # ID -3 20 ALL MIRROR ON PART'NS, FITTING ROOMS & TRIPLICATE MIRRORS X Y INCLUDE TOP AND BOTTOM POLISHED CHROME J MOULDING 21 PORCELAIN TILE FLOORING X Y TILE, GROUT & SEALER SUPPLIED BY CACHE 22 SALES ARE MILLED WALL BASE XY 4 WEEK LEAD TIME 23 CARPET X Y FITTING ROOM AREA ONLY 24 STORAGE & TOILET ROOM VINYL FLOOR TILE & BASE XY INCLUDING VINYL REDUCER STRIPS 25 SATIN STAINLESS STL. FLOORING ANGLES AND MARBLE REDUCER STRIPS XY 26 SALES AREA RECESSED WALL STANDARDS OR FIXTURES X Y 27 FLOOR FIXTURES X Y 28 CASH WRAP COUNTERS X Y 29 END CAPS AND TRIM X Y 30 WORK TABLE / SHELVING UNITS IN STORAGE ROOM X Y 31 TRASH REMOVAL AND DAILY CLEAN UP XY LEGEND,:.. X PURCHASED OR SUPPLIED BY Y INSTALLED BY Z PERFORMED BY N/A NOT APPLICABLE NOTES: THE ENCLOSED PLANS ARE CONSTRUCTION PLANS, TO BE ERECTED BY THE G.C. REFER TO ABOVE RESPONSIBILITY SCHEDULE THAT OUTLINES THE RESPONSIBILITIES OF THE LANDLORD AND CACHE. ALL OTHER RESPONSIBILITY IS THAT OF THE G.C. THE ON-SITE G.C. MUST COORDINATE ALL WORK AND TRADES WITH THE ON-SITE AND OFF-SITE CONTRACTORS. ALL WORK NECESSARY FOR THE COMPLETION OF THIS PROJECT IS TO BE PERFORMED BY THE G.C. UNLESS STATED OTHERWISE IN THESE DOCUMENTS OR LANDLORD'S CRITERIA. ALL MATERIALS, EQUIPMENT AND INSTALLATION NECESSARY FOR THE COMPLETION OF THIS PROJECT TO BE SUPPLIED BY THE G.0 UNLESS STATED OTHERWISE IN THESE DOCUMENTS OR LANDLORD'S CRITERIA. PACKAGE: BY GENERAL CONTRACTOR CEILING SYSTEM 1. FURNISH AND INSTALL CEILING SYSTEMS COMPLETE WITH SUSPENSION SYSTEM AND RELATED ACCESSORIES AS SHOWN ON DRAWINGS AND AS SPECIFIED (SEE FINISH SCHEDULE). 2. SUSPENSION SYSTEM SHALL BE ADEQUATE TO SUPPORT LIGHT FIXTURES, CEILING GRILLES AND DIFFUSERS, AND OTHER NORMAL ACCESSORIES. PROVIDE SYSTEM COMPONENTS FROM SINGLE MANUFACTURER. 3. INSTALL CEILING AND SUSPENSION SYSTEM IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. FINISHED CEILING SHALL BE LEVEL, WITH JOINTS SNUG AND SQUARE, AND TILES OR PANELS IN PERFECT CONDITION. INSTALL SECURITY GRID CLIPS ON FIRST TWO TILES AROUND PERIMETER OF STORE. PAINTING, FINISHING, AND WALLCOVERING 1. THE INTENT IS TO PROVIDE A SATISFACTORY FINISH TO ALL PARTS OF THE PROJECT, WHETHER NOTED HEREIN OR NOT, UNLESS SPECIFICALLY STATED OTHERWISE. COVER ALL SURFACES THOROUGHLY, IF THE NUMBER OF COATS SPECIFIED DOES NOT ACCOMPLISH THE INTENT, THEN APPLY ADDITIONAL COATS OF SPECIFIED MATERIAL TO GIVE SATISFACTORY COVERAGE. SEE FINISH SCHEDULE. 2. USE ONLY THE PAINT AND RELATED MATERIALS OF THE MANUFACTURERS SPECIFIED. 3. CLEAN ALL SURFACES TO BE PAINTED FREE OF LOOSE DIRT AND DUST BEFORE WORK IS STARTED. 4. PAINTED DRYWALL TO RECEIVE ONE COAT LATEX PRIMER AND TWO COATS OF SPECIFIED PAINT. TINT PRIMER TO APPROXIMATE SHADE OF THE FINAL COAT. TOUCH UP ALL SUCTION SPOTS OR HOT SPOTS AFTER APPLICATION OF FIRST COAT AND BEFORE APPLYING SECOND COAT, TO PRODUCE AN EVEN RESULT IN THE FINISH COAT. DRY ALL COATS THOROUGHLY BEFORE APPLYING SUCCEEDING COATS. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR RECOAT TIME. SEAL ALL DRYWALL SURFACES BEHIND MIRRORS. 5. WASH ALL METAL SURFACES WITH MINERAL SPIRITS TO REMOVE ALL DIRT AND GREASE BEFORE APPLYING FINISH. WHERE RUST AND/OR SCALE IS PRESENT, WIRE BRUSH OR SAND CLEAN BEFORE APPLYING FINISH. 6. PUTTY ALL NAIL HOLES, COUNTERSUNK SCREWS, BOLTS, CRACKS, ETC., BEFORE APPLYING FINISH. 7. SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. 8. BEFORE STARTING FINISH WORK, REMOVE HARDWARE, ACCESSORIES, PLATES, LIGHTING FIXTURES, AND SIMILAR ITEMS, OR PROVIDE AMPLE PROTECTION FOR SUCH ITEMS. 9. WOOD DOORS: SEAL BOTTOMS, TOPS, AND EDGES. SAND ALL WOOD DOORS BEFORE FINISHING. 10. MAKE FINISH WORK UNIFORM OR APPROVED FINISH, SMOOTH, FREE OF RUNS, SAGS, AND DEFECTIVE BRUSHING AND CLOGGING. MAKE EDGES OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING. PORCELAIN CERAMIC FLOOR TILE (TILE, GROUT, 7 SEALER SUPPLIED BY CACHE - INSTALLATION BY G.C.) 1. PORCELAIN CERAMIC TILE AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. 2. INSTALL PORCELAIN CERAMIC TILE USING RECOMMENDED METHODS OF THE TILE CONTRACTORS ASSOCIATION OF AMERICA AND THE TILE COUNCIL OF AMERICA, INC. 3. INSTALL PORCELAIN CERAMIC TILE USING WHITE THIN -SET METHOD WITH PORTLAND CEMENT GROUTING MORTAR. JOINTS TO BE A MAXIMUM OF 1/16" IN WIDTH AND NOT BE IRREGULAR IN WIDTH. 4. CAREFULLY CLEAN ALL WORK AND REPLACE OR REPOINT ANY DAMAGED WORK AND LEAVE IN PERFECT CONDITION. USE NO ACID AGENT OR DEVICE THAT WILL MARK SURFACE. SUPPLY AND INSTALL FLOOR CARE PRODUCTS AS SPECIFIED IN FINISH SCHEDULE. 5. TILE GROUT LINES ARE NOT TO EXCEED 1/16" IN WIDTH. CARPET (SUPPLIED BY CACHE - INSTALLATION BY G.C.) 1. DIRECT GLUE DOWN CARPET INSTALLATION. INSTALL AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. 2. FILL ALL CRACKS, JOINTS, ETC. IN SUB -FLOOR WITH CRACK FILLER APPROVED BY CARPET MANUFACTURER. 3. PROVIDE BINDER BAR/EDGE STRIPS AT EXPOSED CARPET EDGES ONLY. DO NOT INSTALL BINDER BAR WHERE CARPETS ABUTT AT ADJACENT WOOD, MARBLE, OR CERAMIC TILE FLOORING. REINFORCED VINYL FLOOR TILE 1. FURNISH & INSTALL AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. 2. 1/8" x 12" x 12" REINFORCED VINYL TILES WITH 4" HIGH x 1/8" THICK, TOPSET, COVED VINYL BASE. SEE FINISH SCHEDULE. 3. FILL ALL CRACKS, JOINTS, ETC. IN SUB -FLOOR WITH CRACK FILLER APPROVED BY FLOORING MANUFACTURER. INSTALL ALL MATERIALS WITH WATERPROOF TYPE ADHESIVES AS RECOMMENDED BY FLOORING MANUFACTURER FOR MATERIALS AND SURFACES INVOLVED. SALES & FITTING AREA WALL BASE 1. FURNISH & INSTALL A 4 1/4" HIGH MILLED WALL BASE AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1 3 2013 City of Tukwila BUILDING DIVISION 3 ' 2z CITY OF TUKWILA APR 1 8 2013 PERMIT CENTER 1 t::. ;7! ..!_DL f?C. U SOUTHCENTER MALL SPACE #640 8897 TUKWILA, WA 98188 EGISTERED ARCHITECT CORTLAND MORGAN STATE OF WASHINGTON FL '!SIU 'lS ! I !_ E I 'i t_ I D-2 GC CHECKLIST ALL ITEMS MUST BE COMPLETED PRIOR TO COMMENCING CONSTRUCTION ITEM DESCRIPTION DATE COMPLETED 1 GC TO COMPLETELY FIELD MEASURE AND VERIFY LOCATIONS OF ALL EXISITING DEMISING WALLS, STRUCTURAL ELEMENTS, AND ITEMS THAT ARE INDICATED AS "TO REMAIN" 2 GC TO REPORT TO MRA DESIGN ANY DISCREPENCIES TO BETWEEN THE PLANS AND FIELD CONDITIONS BEFORE BEGINNING ANY CONSTRUCTION. GC'S REPORT TO CONTAIN FIELD MEASUREMENTS AND SITE PHOTOS 3 GC TO ORDER ALL LONG LEAD TIME ITEMS, SUCH AS WALL BASE AND OTHER FINISHES 4 VERIFY QUANTITY OF CARPET REQUIRED 5 VERIFY QUANTITIES OF WALLCOVERINGS REQUIRED 6 CONFIRM EXISTENCE OF COLUMNS AND COLUMN SIZES 7 ****GC TO PROVIDE WEEKLY PROGRESS PHOTOS TO MRA AND CACHE THROUGHOUT PROJECT 8 ****GC TO PHOTOGRAPH COMPLETED MERCHANDISED STORE WITH ALL LIGHTS ON AND PROVIDE PHOTOS TO MRA DESIGN AND CACHE 3 ' 2z CITY OF TUKWILA APR 1 8 2013 PERMIT CENTER 1 t::. ;7! ..!_DL f?C. U SOUTHCENTER MALL SPACE #640 8897 TUKWILA, WA 98188 EGISTERED ARCHITECT CORTLAND MORGAN STATE OF WASHINGTON FL '!SIU 'lS ! I !_ E I 'i t_ I D-2 EXISTING NEUTRAL PIER TO REMAIN. MALL CIRCULATION EXISTING NEUTRAL PIER TO REMAIN. DEMOLITION PLAN 1/4. a 1'-0" LEASE UNE ADJACENT TENANT EXIST'G RESTROOM TO REMAIN L EXISTING SALES FLOOR REMOVE EXISTING WALL FIXTURES, TYPICAL r L J REMOVE EXISTING WALL FIXTURES, TYPICAL$ -r 1 L REMOVE ALL EXISTING CEILING & FLOORING. TYPICAL AT SALES 7 FLOOR. ri I � i PORTION OF I EXISTING I TERIOR WALL REMO U • EXISTING RESTROOM —19 II gz_i _i 1 EXIST% DEMISING ADJACENT TENANT WALL TO REMAIN, TYP. Cover return air openings before and during construction. Da not abandon any utilities or materials within lease space. Remove back to the source. • • • II i -' EXISTING, STORAGE __•1 REMOVEFLOORING ALL EXISTINGAND I CEILING. TYPICAL AT 7 STOCK ROOM. DEMOLITION LEGEND INDICATES EXISTING PARTITION / CONSTRUCTION & ASSOCIATED HARDWARE TO BE REMOVED. INDICATES EXISTING PARTITION / CONSTRUCTION & ASSOCIATED HARDWARE TO REMAIN. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 13 2013 City of Tukwila BUILDING DIVISION EXIST'G SERVICE DOOR TO REMAIN. DEMOLITION NOTES 1. REMOVE ALL EXISTING STOREFRONT CONSTRUCTION INCLUDING ENTRY DOORS, SOFFITS & LIGHT FIXTURES, PLATFORMS, GLASS PANELS, & NEUTRAL PIER BUILD—OUTS. 2. REMOVE ALL EXISTING PARTITIONS, DOORS & FRAMES, THAT DO NOT APPLY TO THE NEW DESIGN. 3. REMOVE ALL EXISTING MIRROR, WALLCOVERING, MOULDINGS, AND FABRIC AND ANY CORRESPONDING STRUCTURE THAT DOES NOT APPLY TO NEW DESIGN. 4. REMOVE ALL EXISTING SALES FLOOR SHELVING UNITS, HANG RODS, BRACKETS, AND HARDWARE COMPLETELY. 5. REMOVE ALL EXISTING WALL & CENTER FLOOR FIXTURES INCLUDING SERVICE DESK, SHELF UNITS, DISPLAY UNITS, SIGNAGE / DISPLAYS, ETC. COMPLETE W/ LIGHTING & WIRING. 6. REMOVE All.. EXISTING FLOOR FINISHES AND ADHESIVE. PATCH, PREPARE, AND CLEAN FLOOR TO ACCEPT NEW FLOOR FINISH. 7. REMOVE ALL FURRING, PANELING, ETC. THAT DO NOT APPLY TO NEW DESIGN TO EXISTING GYP. BOARD DEMISING WALL PATCH AND PREPARE ALL EXISTING GYP. BOARD DEMISING WALLS FOR NEW FINISH BY GENERAL CONTRACTOR. 8. REMOVE ALL EXISTING CEILINGS INCLUDING ALL LIGHT FIXTURES, (W/ WIRING & CONDUITS ALL THE WAY TO SOURCE). REFER TO ELECTRICAL DRAWINGS FOR FULL SCOPE OF NEW WORK. 9- WHERE ELECTRICAL WORK IS NOT BEING REUSED REMOVE ALL EXISTING DEVICES, WIRING/CONDUITS ALL THE WAY TO THE SOURCE. DO NOT JUST ABANDON. REFER TO ELECTRICAL DRAWINGS FOR FULL SCOPE OF NEW WORK. 10. REFER TO MECHANICAL DRAWINGS FOR FULL SCOPE OF HVAC NEW WORK & ASSOCIATED DEMOLITION WORK. 11. COORDINATE ALL DEMOLITION & BARRICADE W/ MALL OPERATIONS. 12. IF THERE IS AN EXIST'G "XPONDR" SYSTEM, REMOVE, DO NOT DAMAGE, & RETAIN TO BE RETURNED TO CACHE. b 2 2 RECEIVED CITY OF TUKWILA APR 1 8 2013 PERMIT CENTER 3.26.2013 1 At) V SOUTHCENTER MALL SPACE 1640 'CORTLAND MORGAIV STATE OF WASHINGTON weimmonem DEMOLITION PLAN D-1 ADJACENT TENANT ®'m w o - ® - ® 5'-5$„ FURR OUT WALL FOR RECESSED STANDARDS 76' - VERIFY SEMI RECESSED FIRE EXTINGUISHER CAB. MOUNTED 15 55" AT TOP OF CAB. CAB IS LESS THAN 75' TRAVEL DISTANCE FROM ALL AREAS OF TENANT SPACE. 6'-2" 8'_82" i' e' 1 e e e 1 1 e MALL CIRCULATION 1 1 1 1 SEE EXISTING STOREFRONT PLAN ON DWG #ID -5 V 1 1 DATITIO SLA 1/4" = 1'-0„ 1 1 1 1 1 1 1 1 1 1 1 1 1 v 5'-58„ A 11. } 1� 1 ' 1 SHOW WINDOW! 1 1 1 1 `. 1 1 1 1 1 1 1 1 1 1 1 1 f.. 1 1 1 1 1 SHOW WINDOW! 1 1 1 1 i 1 1 1 1I� 1 N STRIPE FLOOR T0. INDICATE 44" CLEAR PATH OF TRAVEL. BACK DOOR TO HAVE TENANT NAME AND ADDRESS WITH 1" HIGH WHITE LETTERS ON 2" RED VINYL TAPE PER MALL CRITERIA. ADA FITTING ROOM' r0 SALES FLOOR 24'-1 A"VERIFY 3'-0" 0 EQ. Jl 6' - EQ. rn 14 2'- 2' 0 N) 4'-0 FITTING ROOM AREA 4'-O" STOCK. ROOM FITTING ROOM FITTING ROOM 6'-2" 6'-2" 7'-11" 2'-2" ADJACENT TENANT DOO SC O1 ENTRY O CLOSET REAR 0 SERVICE ENTRY DOUBLE 3'-0" x +8'-0" (FIELD VERIFY) x 1/2"TH CLEAR TEMPERED GLASS DOORS. "VIRGINIA GLASS" DOOR STYLE "BP" W/ CONTINUOUS 4"H BOT. SQUARE RAIL & TOP PATCH PIVOT HINGE. SINGLE ACTING IN -SWINGING DOORS W/ STANDARD BOTTOM RAIL LOCK #VIR-58 & STRAIGHT THROW BOLT (KEY ON MALL SIDE. - THUMB TURN ON CACHE SIDE). CYLINDER TO BE INSTALLED MUST BE "BEST" MORTISE CYLINDER W/ INTERCHANGEABLE CORE. CACHE'S DISTRICT MGR. WILL BE RESPONSIBLE FOR INSTALLING "BEST CORE LOCK" SPRING DUSTPROOF FLOOR STRIKE COVER (POPS UP WHEN DOOR IS NOT LOCKED). ALL METAL FINISHES TO BE SATIN STAINLESS STEEL, #8. DOORS W/ HARDWARE AVAILABLE FROM: VIRGINIA GLASS TEL: 1-800-368-3011 PUSH-PULL HARDWARE: "ELMES, INC" #T1780, FINISH: ANODIZED SILVER LEFT: #T1780 -25-038-L BACK TO BACK RIGHT: #11780-25-038-R BACK TO BACK INSTALL EXTRA RECESSED FLOOR STRIKES FOR EACH "HOLD OPEN POSITION". CEILING HEIGHT OPENING W/ FABRIC CURTAIN SET IN 4 H RECESS. HARDWARE SUPPLIED BY CACHE, INSTALLED BY ONSITE G.C. DOOR TO LOCK DOORS IN CEILING HEIGHT OPENING W/ FABRIC CURTAIN SET IN 4"H RECESS. HARDWARE SUPPLIED BY CACHE, INSTALLED BY ONSITE G.C. CURTAIN W/; CURTAIN W/ 3'-0 x 6'-8" x 1 3/4" TH. HOLLOW METAL FLUSH DOOR W/ STANDARD FRAME. FINISH FITTING ROOM SIDE OF DOOR PLAST. LAM. (PL1 )(PROVIDED .BY' CABINETRY CONTR., APPLIED BY ONSITE MILLW•:. CONTRACTOR). PAINT FINISH FRAME & STOCK ROOM SIDE OF DOOR . - 2 PAIR STANLEY 4 BUTT HINGES SATIN ST.. STL #4 FINISH. - "SCHLAGE" S SERIES JUPITER LEVER STORAGE LOCK SET, FINISH 626 SATIN CHROME: - 8"x34 KICK PANEL ON FITTING ROOM SIDE, FINISH #626 BRUSHED ST/STL: - CONCEALED OVERHEAD SELF -AUTOMATIC DOOR CLOSER "LCN SUPER SMOOTHIE" SERIES #4040 ON STOCK ROOM SIDE. 3'-0." x 6'-8 x 1 3/4" TH. HOLLOW METAL FLUSH DOOR W/ STANDARD FRAME. FINISH: PT1 ALL SIDES - 2 PAIR STANLEY 4" BUTT HINGES SATIN ST. STL #4 FINISH. - "SCHLAGE S SERIES JUPITER LEVER PRIVACY LOCK SET, FINISH 626 SATIN CHROME. DOOR & FRAME COMPLETE W/ HARDWARE SUPPLIED BY CABINETRY CONTRACTOR, INSTALLED BY ON SITE MILLWORK CONTRACTOR. N/A EXISTING 3'-0" X 7'-0" "B" LABEL SERVICE DOOR. FINISH EGRESS CORRIDOR SIDE OF DOOR / FRAME PAINT (PT1) PAINT SERVICE CORRIDOR SIDE OF DOOR / FRAME & PROVIDE SIGNING AS PER LANDLORD REQUIREMENTS. ON SITE G.C. TO INSTALL THE FOLLOWING ITEMS: • OVERHEAD AUTOMATIC DOOR CLOSER ON CACHE SIDE OF DOOR (INSIDE) "CCN SUPER SMOOTHIE" OR EQUAL. • FIRE EXIT DEVICE W/ BATTERY ALARM BY "DETEX" OR EQUAL. • DEADLOCK -BLANK FACE PLATE AT CORRIDOR SIDE, PUSH BAR OPERATED AT INSIDE. SELF LATCHING FEATURE WHEN DOOR IS CLOSED. • UL -RATED PEEP HOLE AT +60"AFF 35'-54" -2g' SYMBOL aas a ®.a O • FURR OUT WALL FOR RECESSED STANDARDS ARTITIO\ L DESCRIPTION =G \D FULL HEIGHT DEMISING PARTITION. PATCH / REPAIR GYPSUM BOARD WHERE NECESSARY TO MAINTAIN 1 HR FIRE RATING PER UL #U495: PREPARE WHERE NECESSARY TO RECEIVE NEW FINISH. NEW NOMINAL 5" TH. CEILING HEIGHT PARTITION WITH 3 5/8" (20 GA.) MTL STUD FRAMING AT 16" 0.C. WITH 5/8" TYPE "X" GYPSUM BOARD EACH SIDE. EXTEND MTL STUDS TO 6' ABOVE FINISHED CEILING & SECURE W/ DIAGONAL BRACING TO STRUCTURE ABOVE (NOT DECK). EXTEND GYP. BD ON STOCK ROOM SIDE 'TO 3" ABOVE ACOUSTIC TILE CEILING.. EXTEND GYP BD ON FITTING ROOM & SALES FLOOR .SIDES TO FINISHED CEILING. NEW CEILING HEIGHT PARTITION .W/ (20 GA) METAL STUD FRAMING & SOUND ATTENUATION BLANKET. APPLY ONE LAYER 5/8" WATER RESISTANT GREENBOARD ON TOILET ROOM SIDE AND 5/8 TYPE "X" GYP. BD ON FITTING ROOM SIDE. EXTEND METAL STUD FRAMING TO 3'. ABOVE FINISHED CEILING.: EXTEND GYPSUM BOARD / GREENBOARD TO FINISHED CEILING. NEW ±4 5/8"DEEP CEILING HEIGHT PLUMBING CHASE W/ 4" (18 GA) METAL STUD FRAMING. APPLY ONE LAYER 5/8" WATER RESISTANT GREENBOARD ONE SIDE. EXTEND GREENBOARD & MTL STUDS TO .FINISHED CEILING. NEW 2 3/8" DEEP (VERIFY IN FIELD) CEILING HEIGHT FURR-OUT W/ 1 5/8" METAL STUD FRAMING: APPLY ONE LAYER 5/8" TYPE "X" GYP. BD. EXTEND METAL STUD FRAMING TO 3" ABOVE FINISHED CEILING, EXTEND GYPSUM BOARD TO FINISHED CEILING. NEW NOMINAL 3 3/4" TH. CEILING HEIGHT PARTITION WITH 2 1/2" (25 GA.) MTL STUD FRAMING AT 16" 0.C. WITH 5/8" TYPE "X" GYPSUM BOARD EACH SIDE WHERE REQUIRED (SEE PLAN). EXTEND MTL STUDS & GYP. BD TO FINISHED CEILING. G.C. TO INSTALL BLOCKING FOR FITTING ROOM GARMENT HOOKS. SEE DETAIL A,' ID -8 NEW, COLUMN ENCLOSURE, APPLY ONE LAYER 5/8" TYPE "X" GYPSUM BOARD OVER METAL FRAMING. EXTEND GYP. BD & FRAMING. TO DECK ABOVE. TAPE / SEAL To MAINTAIN 1 HR FIRE RATING. 5" It 5/8" TYPE "X" GYP. BD. CLG, ERTICAL GRAB BAR TJ COMPLY W/ ANSI 604.5.1 GRAB BAR v) 0 M 3,-3" 1'-O"MA) 3'-6" 1 9„ w z U J 4"BASE TOILET PAPER HOLDER 5/8" TYPE "X". GYP. BD. CLG. 36" 0 GRAB BAR 3 a M > J 0 0 0 18"x36" MIRROR 1 i 0 0 m OF MIRROR 6'-4" MIN TO 18" TO HOLD L -T ROOV EL 15" 4"BASE -VAT 0\ S 3/8" = 1,-0" 14'-341" EXISTING STAIR TO MEZZANINE (NOT IN SCOPE) OTE: G. C. TO V DIV- \SIO\S BEFO BEG \\I\G CO\ST A\D IV V-DIAT-LY A\Y VARIATIO\ 0JECT 0008 FY ALL RUCT 0\ ESOT S TO THE 3I\ATOS C.C.' COORDINATION FOR SECURITY SYSTEM: PRIOR T0: CLOSING IN ENTRY COLUMN ENCLOSURES, BUILDING SHOW WINDOW PLATFORMS, INSTALLING TILE FLOORING & PREFERABLY AFTER ALL SALES AREA FLUORESCENT LIGHTING HAS BEEN INSTALLED THE ON SITE G.C. IS TO CONTACT: "XPONDR" ATTN: FIELD SERVICE PH: 888-601-4800 TO COORDINATE SECURITY SYSTEM INSTALLATION UNDER FLOOR & IN ENTRY SOFFIT. REFER TO "XPONDR" DETAILS ON DWG #ID -4 & #E-1. CONSTRUCTION NOTES: CODE COMPLIANCE PPROVED I41,;"( 132013 CilyofT(J jla °1,.4NG DIVISION 1. ON SITE G.C. SHALL VERIFY ALL FIELD CONDITIONS & SHALL HAVE SOLE RESPONSIBILITY FOR VERIFICATION OF CLEAR HEIGHTS & FLOOR DEPRESSIONS WITHIN THE BASE BUILDING. 2. ON SITE G.C. PRIOR TO ERECTING ANY NEW PARTITIONS TO FIELD SURVEY & COORDINATE ALL CLEAR DIMENSIONS W/ CABINETRY CONTRACTOR TO ENSURE PROPER FIT OF . CASEWORK & FIT. RMS. THERE IS NO MARGIN FOR ERROR. 3. ON SITE G.C. TO REFER TO DWG #ID -8 FOR ALL DRYWALL / WOOD CAP DETAILS AND CONDITIONS. 4. ON SITE G.C. TO APPLY NEW FIRE CAULKING ALONG DEMISING WALLS OR PATCH/REPAIR EXISTING FIRE CAULKING. FIELD VERIFY EXISTING CONDITION. WATER CLOSET LAVATORY "AMERICAN STANDARD" CADET ADA 161"H ELONGATED TOILET #2998.012 W/ LOW CONSUMPTION 1.6 GA FLUSH. WHITE VITREOUS CHINA. PROVIDE WHITE STANDARD SOLID PLASTIC OPEN END SEAT, +18"MAX SEAT HEIGHT. "OLSONITE #10CC WHITE OR APPROVED EQUAL. 'AMERICAN STANDARD" COMRADE WALL HUNG LAVATORY# 0124:131, 18 1/4"D x 20"W W/ 4 O.C. CENTERS & CONCEALED ARM SUPPORTS: WHITE VITREOUS CHINA. INSTALL RIM TOP NO HIGHER THAN +34" AFF. PROVIDE MINIMUM +29" AFF. TO BOTTOM OF APRON FOR KNEE CLEARANCE. HOT WATER & DRAIN PIPES UNDER LAVATORY SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. "AMERICAN STANDARD" MONTERREY #7502.170 CENTER SET LAVATORY FAUCET W/ GOOSENECK SPOUT, WRIST BLADE HANDLES, GRID STRAINER DRAIN, & FLOW RESTRICTORS. POLISHED CHROME FINISH. SEE DOOR SCHEDULE TYPE : O 5 ON THIS DRAWING. "BOBRICK" #B-290 1836 SURFACE MTD SATIN ST/STL FRAMED MIRROR 18"W x 36"H. MOUNT BOT: OF MIRROR AT +40"AFF, CENTER MIRROR OVER LAVATORY. FAUCET DOOR FLAT MIRROR TOILET PAPER HOLDER PAPER TOWEL BAR POLISHED CHROME SURFACE MTD TOILET PAPER HOLDER. MOUNT CENTER OF HOLDER AT +19" AFF. & WITHIN 7" TO 9" FROM FRONT EDGE OF TOILET SEAT, POLISHED CHROME ROLLER TOWEL BAR, 12" LONG. MOUNT BAR AT + 42" AFF. ON WALL ADJACENT TO LAVATORY. "BOBRICK" B-6106 x 36" LONG STRAIGHT GRAB BAR MOUNTED ON WATER CLOSET REAR WALL W/ END OF BAR SET 6" FROM INSIDE CORNER. "BOBRICK" 3-6106 x 42" LONG STRAIGHT GRAB BAR MOUNTED ON WATER CLOSET SIDE WALL W/ END OF BAR SET 12" FROM INSIDE CORNER. STAINLESS STEEL TUBING 1 1 /2" 0.D. W/ WELDED FLANGES. MOUNT GRAB BARS AT +35" AFF. TO CENTER OF BAR. BAR FASTENERS & MOUNTING SUPPORT SHALL BE ABLE TO WITHSTAND 250 LBS:/FT. IN BENDING, SHEAR, & TENSION. RECEIVED M CITY OF TUKWIILA AY 0 6 2 013 PERMIT rs,,T 1741 DATE: 3.26.2013 JOB NO: DRAWN: CHECKED: 711 N. FIELDER RD. ARLINGTON, TX 76012. PH: (817) 635-5696 FAX: (817) 635-5699 0 LIJ 0 0 co c W Z W 0 1 D 0 A 4.30.2013 REVISIONS 8897 n CORTLAND MORGAN STATE OF WASHINGTON PARTITION PLAN SHEET NUMBER ID -3 SEMI RECESSED FIRE EXTINGUISHER CAB; MOUNTED @ 55" AT TOP OF CAB. CAB IS LESS THAN 75' TRAVEL DISTANCE FROM ALL AREAS OF TENANT SPACE. STRIPE FLOOR TO INDICATE 44" CLEAR PATH OF TRAVEL. PATH OF EGRESS 39'-10" 36" H. KNEE WALL TO SEPARATE PATH OF EGRESS 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 SALES FLOOR STOCK ROOM EXISTING STAIR TO MEZZANINE (NOT IN SCOPE, NOT USED) FITTING ROOM AREA REVIEWED FCR CODE COMPLIANCE APPROVED MAY 13 2013 FURR OUT WALL FOR RECESSED STANDARDS Note to city inspectors: The yellow hi-lighted/clouded path is the portion of the egress system that is required to be tested to confirm compliance with section 1006.4 IBC. \GJISH EXIT SIG\ 2009 IBC MEANS OF EGRESS ILLUMINATION 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the. means of egress is occupied. 1006.2 Illumination level. The means of egress illumination level shall not be less than 1 foot-candle at the walking surface. 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways... 3. Exterior egress components... 4. Interior exit discharge elements... 5. Exterior landiings...for exit discharge doorways... LIFE SAFETY DLA\ IS I\ FULL ACCODA\CE A\D COVPLIA\CE WIT- \FPA 101- LIFE SAFETY DEQREvE\TS EXIT .OUT �E VANE\ 3UILDI\G I\CLLDES FRE ALARM SYSTEvI/DEVICES A\D \IOTIEICATIO ADPLIA\CES - ADI3LE, VISHLE. 2009 IBC MEANS OF EGRESS ILLUMINATION 1006.4 Performance of system. Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle and a minimum at any point of 0.1 foot-candle measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ration of 40 to 1 shall not be exceeded. 00 00 TM- W/� VO Q Q J F - CCW H CD W U 2 H O 1(7\1 - REVIEWED N \GUTS REVISIONS ALL EXIT .DOOS vUST BE U\LOC<ED EVPLOYEES PATI -\TS MUST BE ABLE TO OPE\ A\ EXIT 30.JTE DOO' E'OV THE INSIDE AT ALL TI V ES WIT -OUT <EYS, TOOLS 0SPECIAL <\IOWLEDGE. A : DEVICE SUC- AS ADA` IC 3A THAT LOC<S 0\LY F�OIV THE OUTSIDE IS D -WITTED 0\ EXIT DISC -AGE DOOS. OBJECTS T -AT 'DOJ -CT I\TO THE EXIT ROUTE IvUST \OT .EDUCE T-- WIDTH OF THE EXIT ROUTE TO LESS THA\ THE NI\IVEN WIDTH EQUI�ENENT FOE: EXIT ROUTES. REGISTERE ARCHIT.E', CORT.LAND MORGAN STATE OF WASHINGTON CA3I\ET NOU\TI\G HEIG-T THE DISTANCE E Ov THE FLOO TO THE TOD OF THE EIS- EXTI\GUISHETO BE \O IVOE THA\ 5 FEET. L8" EEOv A.F.E. TO BOTTOv OF CABINET. WALL M OU \ TES / -CESS SHOULD \OT DOT,DE EOM WALL \O v1OE THA\ 4" BETWEE\ 27" AND 80" I\ PASSAGEWAYS/COIDOS LIFE SAFETY PLAN RECEIVED CITY OF TUKWILA MAY 0 6 2013 PERMIT CENTER SHEET NUMBER ID -3a BRUSHED BRONZE FLOORING ANGLE 1/8"TH x 3/8"H x 1 1/2"L. (BY ON SITE G.C.) GLUE -DOWN CARPET Cc -F) FEATHER EDGE CARPET SO THAT ALL FINISHES ALIGN FLOORING DETAIL FULL SIZE LEASE LINE ADJACENT TENANT DI PLAY WINDOW RECESSED STANDARDS, TYP. MATCH MALL TILE TO CENTERLINE OF = STOREFRONT CLOSURE MALL CIRCULATION INDICATES SAWCUT CHANNEL UNDER FLOOR TILE FOR "XPONDR" LOOPWIRE �.. I 1•• • EXISTING STOREFRONT TO REMAIN FLOOR PLAN LEASE LINE DISPLAY WINDOW SALES AREA ( T1 )• EXISTING TO REMAIN PATCH & REPAIR AS REQUIRED ACCESSIBLE ADA BENCH, MOUNTED TO WALL CLOTHES RAIL (ABOVE) SEMI RECESSED FIRE EXTINGUISHE 0 P OF CAB. IS LESS THAN 75' TRAVEL DISTANCE FROM ALL AREAS OF TENANT SPACE. STRIPE FLOOR TO INDICATE 44" CLEAR PATH OF TRAVEL STRIPE WITH: ARMSTRONG EXCELON, LEMON YELLOW 51812 & CHERRY RED 51816 VCT U) 7 II. U tX 8 • \` • H1 > .> -*1 --,_ 41 >67. tn \.... M 21 F113 - ; =ii ADA �, FITTING _, ROOM EIVI/ fl,?N}h 1'H1515kJiflf-: H11 M2 LIGHTED HINGED TRIP. MIRR F8 D1 CURTAIN, TYP. •-( C1 )-" 1 5j HFITTING i ROO "—(Cl)--. M5 D1 CURTAIN, TYP. I4ViP lut'N •r t.N�1t J'. / "4C1 • FIT i G� rf TING ROOM UN. - 1/4" = 1'-0 PORCELAIN FLOOR TILE 17" x 17" ON THIN SET INSTALLATION. SHIM / FEATHER EDGE TILE SO THAT ALL FINISHES ALIGN —TOP OF CONCRETE SLAB (T1 ) IJ ON SITE G.C. TO FIELD VERIFY EXISTING CONCRETE SLAB CONDITION. MODIFY SLAB TOPPING AS REQ'D. TO INSURE A UNIFORM FLOORING TRANSITION THRU—OUT SPACE. 18" CACHE INDICATES 1 /4"Wx1 /2"D SAWCUT CHANNEL BY ONSITE G.C. TO CONNECT ANTENNA RELIEFS W/ LOOPWIRE CHANNEL. PORCELAIN FLOOR TILE 17"x-17" ON THIN SET INSTALLATION (T1 MALL NEW GLASS PANEL ENTRY DOORS NEW MALL FLOORING 1/2"Wx1"D SAWCUT CHANNEL BY ONSITE G.C. FOR "XPONDR" LOOPWIRE & ANTENNA CABLING. FLOORING 1/2" DETAIL FULL SIZE 20min QUICKSET CEMENT BY ONSITE - `. G.C. 457 6 1/2" 1 /8"TH. SATIN ST. STL FLOORING ANGLE BY G.C. 6 1/2"x4 1/2"x1 1/2"D RELIEF CUT <— INTO EXISTING SLAB BY ONSITE G.C. FOR "XPONDR" ANTENNA' INSTALLATION (3 REQUIRED). FLOOR ANTENNA SUPPLIED & INSTALLED BY "XPONDR" (3 TOTAL).: FIELD VERIFY EXIST'G CONDITION VTI) VINYL COMPOSITION FLOOR TILE TOP OF EXISTING CONCRETE SLAB "MERCER" IMPERIAL C/E REDUCER STRIP STOCK No.700 COLOR No.201 BROWN ( C1 ) GLUE -DOWN CARPET D1 CUR AIN, TYP. ZOM L.: N) 36" HIGH KNEE WALL TO SEPARATE PATH OF EGRESS 6 5 In M cn In ••--(. VT1 )--" _. STORAGE )IS30 S,213OVNYP4 LS I� FLOORING DETAIL FULL SIZE BRUSHED BRONZE FLOORING ANGLE 1 /8"TH x 3/8"H x 1 1 /2"L. (BY ON SITE G.C.) PORCELAIN FLOOR TILE (T1 ) ON THIN SET INSTALLATION ALIGN PORCELAIN FLOOR TILE T2 ) 12"x 24" ON THIN SET INSTALLATION - TOP OF CONCRETE SLAB FLOORING DETAIL FULL SIZE ON SITE G.C. TO FIELD VERIFY EXISTING CONCRETE SLAB CONDITION. MODIFY SLAB TOPPING AS REQ'D. TO INSURE A UNIFORM FLOORING TRANSITION THRU—OUT SPACE. LEASE LINE fiEWE'D FOR CODE COMPLIANCE � P '"OVER Ar KAY 1 3 2013 Cit'- of Tukwila 111L 1 .NG DIVISION NON—COMBUSTIBLE BLOCKING MUST BE PROVIDED OR STIFFENERS INSTALLED IN LANDLORD DEMISING WALLS TO PREVENT STUD DEFLECTION AS THE RESULT OF SHELVING/FIXTURES MOUNTED TO DEMISING WALLS. FURR OUT AS REQUIRED TO ENSURE THAT STRUCTURAL INTEGRITY OF LANDLORD DEMISING WALLS REMAINS INTACT (TYP). 13 -Nb. �zz kninenreu RECEIVED ITY OF TUKWILA MAY 0 6 2013 PERMIT CENTER iiPMENOMMORMARIMENFIRMI DATE: 3..26.2013 JOB NC): DRAWN: CHECKED: 71 1 N. F 11 1 7!::I ARLIN(•.TON, lX 7.C;(:)I PH: (8'17) 63R --U FAX:. (`t I i) 6:35---!'.',4-;t! , /,\ 4.30.2013 8897 REGISTER ARCWITT CORTLAND MOR STATE OF WASHINGTON 00 W 0) -J a CC w z w 0 FI 0 sj N FLOOR PLAN D-4 sa FIXTURE INDEX SYMBOL DESCRIPTION D1 FITTING ROOM CURTAINED OPENING (INSTALLER TO FIELD MEASURE) CURTAIN SUPPLIED & INSTALLED BY CACHE'S DRAPERY CONTRACTOR F6 FITTING ROOM STOOL (FURNISHED BY CACHE) F8 FITTING ROOM SALON - OTTOMAN (FURNISHED BY CACHE) ALL ITEMS BELOW ARE FURNISHED BY CACHE & INSTALLED BY G.C. D2 LAMINATE- APPLIED TO FITTING ROOM SIDE OF DOOR. SEE DOOR SCHEDULE ON DWG # ID -3 FR# FIT. RM PACKAGE- WOOD TRIM ( COMPLETE W/ HDWR), BASE, BACK LIT MIRROR, STOOL, U -RAIL& BENCH AT HC FITTING ROOM M1 FITTING ROOM MIRROR UNIT 2'-4"W X 8'-0"H, MOUNTED ON 4" BUILD -OUT W/ CONCEALED VERTICAL FLOURESCENT STRIP LIGHTING M2 FITTING AREA TRIPLE MIRROR UNIT 2'-4"W X 8'-0"H W/ 4" BACKLIT FROSTED GLASS BORDER & 21" HINGED SIDE PANELS M3 FRAMED MIRROR UNIT. (DIMENSIONS VARY- REFER TO ELEVATIONS DWG # ID -7) M5 FRAMED MIRROR UNIT (DIMENSIONS VARY- REFER TO ELEVATIONS DWG # ID -8) F1 SIDE SHOWCASE LINE WI CASH WRAP UNIT & REAR WALL COUNTER F2 SALES FLOOR / WALL MTD HANGING WALL FIXTURE F5 FITTING ROOM WALL MTD GARMENT "U" BAR & PURSE TABLE F7 ADA COMPLIANT FITTING ROOM BENCH - MUST BE SECURED TO WALL H1 GARMENT HOOK MTD 6'-6" AFF H2 DRAPERY TIE BACK H3 GARMENT HANG BAR WI BACK PANEL (PROVIDE BLOCKING IN WALL) S1 DESK AND CABINET- 2'-0"D X 4'-0"L X 30"H S2 TISSUE PAPER UNIT 21"D X 30"L S3 HANGING / SHELVING UNIT 16"D X LENGTHS VARY FILE CAB. 4 DRAWER MTL FILE CABINET ( 13 -Nb. �zz kninenreu RECEIVED ITY OF TUKWILA MAY 0 6 2013 PERMIT CENTER iiPMENOMMORMARIMENFIRMI DATE: 3..26.2013 JOB NC): DRAWN: CHECKED: 71 1 N. F 11 1 7!::I ARLIN(•.TON, lX 7.C;(:)I PH: (8'17) 63R --U FAX:. (`t I i) 6:35---!'.',4-;t! , /,\ 4.30.2013 8897 REGISTER ARCWITT CORTLAND MOR STATE OF WASHINGTON 00 W 0) -J a CC w z w 0 FI 0 sj N FLOOR PLAN D-4 sa ADJACENT TENANT NEW GYP. BD. CEILING AT EXISITING HEIGHT. PAINT PT2 TYP. ` (ALL FRONT OF THE HOUSE LOCATIONS) GYP. BD. TROUGH TO RECESS RACK LIGHTING. TAIL THIS SHEET EXISITNG GYP. BD. CEILING TO REMAIN PAINT PT2 NEW 24"x48" ACOUSTIC TILE LAY -IN CLG AT +11'-6" AFF. (STOCK ROOM LOCATION ONLY) (ACT1) EXISTING SSED CLG MTD ELECTRICAL — DUPLEX OUTLET CACHE SUPPLIED 5' LONG BANNER TRACK SURFACE MOUNTED AS SHOWN BY ON-SITE G.C. EXISTING STOREFRONT TO REMAIN " TYPE "X" GYP. BD SOFFIT TO REMAIN PT2 RUN VERTICAL FIRE PIPE IN THIS LOCATION (IF REQUIRED) CAT 5 CABLE FOR "PEOPLE COUNTER" FLUSH 24" x 24" ACCESS DOOR MTD IN ENTRY SOFFIT. "MILCOR" STYLE ATR W/ CYLINDER KEY LOCK. FIELD INSTALL GYP. BD FACING & CASING BEADS. FINISH TO MATCH CEILING. CACHE SUPPLIED 5' LONG BANNER TRACK SURFACE MOUNTED AS SHOWN BY ON-SITE G.C. REVIEWED FOR CODE COMPLIANCE APPROVED ADJACENT TENANT GYP. BD HEADER BOT. PAINT PT2) FINISH STAGGERED DOUBLE TUBE FLUORESCENT LIGHT FIXT., TYPE F MAIN SUSPENSION SYSTEM AS MANUFACTURED BY USG INTERIORS "RIGID X DONN SUSPENSION SYSTEM" OR EQUAL SECURED TO BOT. BOT OF STRUCTURE ABOVE W/ VERTICAL HANGER WIRE (9 GA) CEILING 1. ON SITE G.C. TO PROVIDE & INSTALL A MASTER CONTROL SWITCH. FOR ALL LIGHTING (EXCEPT SHOW WINDOW LIGHTING). 2. ALL EMERGENCY LIGHTING, EXIT SIGNS, AND NIGHT LIGHTS SHALL BE WIRED TO THE PANEL BOARD, AHEAD OF ANY LOCAL SWITCHING. 5/8" TYPE "X" GYP. BD, PAINT (PT2 "LIGHTOLIER" CMH LAMP HOLDER ON CONT. SUSPENDED TRACK CONSTRUCTION NOTES: 1. * SYMBOL INDICATES EMERGENCY LIGHTING LOCATIONS. REFER TO LIGHTING LEGEND THIS DRAWING FOR FIXTURE SPECS. 2. ON SITE G.C. TO PROVIDE ACCESS TO ALL DUCTWORK, HEATERS, PIPING, CONTROLS, OR VALVES LOCATED WITHIN THE PREMISES (WHETHER TENANT OR BASE BUILDING SYSTEMS) BY MEANS OF ACCESSIBLE CEILING TILE OR FLUSH ACCESS PANELS. 3. CEILING SYSTEMS TO BE SUSPENDED FROM STRUCT. STEEL ONLY. CONNECTION TO LANDLORD'S METAL DECK IS NOT PERMITTED. 4. ALL ELECTRICAL AND MECHANICAL COMPONENTS ABOVE CEILING TO BE GROUPED TOGETHER AND LOCATED OVER STOCK ROOM AS MUCH AS POSSIBLE TO KEEP THE QUANTITY OF REQUIRED CEILING ACCESS PANELS TO A MINIMUM. ALL ACCESS PANELS TO MATCH PANEL SPECIFIED IN ENTRY VESTIBULE. LIGHTING LEGEND SYMBOL MANUFAC-URER MODEL # LAMP VOLTAGE NUMBER DESCRIPTION A ALO ! A LIGHTOLIER 8242HU 8038CLW/1951 (2) 33W CFL 120V / 66W _ SALES FLOOR COMPACT FLUORESCENT 2 LAMP 8" OPEN REFLECTOR DOWNLIGHT CLEAR ALZAK CONE & WHITE FLANGE, INTEGRAL W/ ELECTRONIC BALLAST A 0,01LIGHTOLIER U 8242H W/1951 8W/ (2) 33W CFL 120V / 66W ' - SALES FLOOR EMERGENCY DOWNLIGHT. SAME AS TYPE 'A' ABOVE EMERGENCY OPTION & ON 24 HR NIGHT LIGHT CIRCUIT. �1. B �I. -e=� LIGHTOLIER Lightalier #22553WH-25W MAX 42345-13PAR3os/END/F25 3000 DIM 12pV / _ _ CEILING MTD PERIMETER LIGHT TRACK WI LED LAMPS ALL PARTS WHITE FINISH. D •i ! LIGHTOLIER MAX 42345 42345 13PAR305/END/F25 3000 DIM 120V / 13W - RECESSED (1) LAMP ADJUSTABLE SPOT LIGHT. MERCURY LIGHTING STAG SERIES (2) T5 28W BULBS (2) T5 21W BULBS - 120V / 56W 120V / 42W - - STAGGERED DOUBLE TUBE FLUORESCENT LIGHT STRIPS 3', 4', & 6' LENGTHS W/ ELECTRONIC BALLAST illr4. lihil 49" F 3 37-1/4" miin F 2 25-7/16" LUKAS LIGHTING CUSTOM (4) 13W 4 -PIN QUAD 120V / - - FITTING ROOM SALON CUSTOM PENDANT LIGHT FIXTURE. & // COLUMBIA FL4L2X4TRELE (2) 4' T-8 3500'K 120V / - - STORAGE ROOM RECESSED 2 X 4 LAY -IN 2 -LAMP FLUORESCENT LIGHT FIXTURE W/ ELECTRONIC BALLAST, & ACRYLIC LENS JUNG LIGHTING Juno M5382WH-25W MAX 42345 13PARsos/EN5/F25 3000 DIM 120V / 25W - RECESSED FIXTURE FOR STOREFRONT WINDOW. SUITABLE FOR FOR EXTERIOR ENTRANCE DAMP LOCATION. LED LAMPS EX LIGHTALARMS SPLEDWRCD - 120V / - - SALES FLOOR / FITTING ROOM WALL OR CEILING MOUNTED EMERGENCY EXIT LIGHT SIGN FIXTURE W/ BATTERY BACK-UP. CLEAR ACRYLIC PANEL WI RED LETTERS & WHITE FACE PLATE. 1>421 EX2 PRESCOLITE NAPEXHC3RECCBW - 120V / - - STORAGE ROOM UNIVERSAL MOUNT EMERGENCY LIGHT & EXIT SIGN FIXTURE W/ BATTERY BACK-UP. ALL INSTALLED THIS AND RECEIPT. MS 1A E MASTER SHUT-OFF SWITCH FOR ALL LIGHTING - RECESSED CEILING MOUNTED AUDIO SPEAKER WITH GRILLE. " " "POSH 5.25 RETRO CEILING SPEAKER" FOR INSTALLATION IN CEILING LIGHTING CONTACTOR GE #460XEIB TILE OR SHEETROCK, PREFINISHED WHITE GRILLE & BEZEL, SELF WALL MOUNTED LIGHT SWITCH CONTAINED IN STEEL HOUSING. AVAILABLE FROM: "DMX MUSIC" ATTN: MARISA CLIPSON PH: 1 AMP CURRENT LIIMITER (800)831-8001 SPEAKER W/ GRILLE SUPPLIED BY CACHE. INSTALL W/ 16 GA OCCUPANCY SENSOR SWITCH #SPT/162 WIRE. Q SAME AUDIO SPEAKER & GRILLE SPEC AS ABOVE- EXCEPT W/ BUILT-IN RECEIVED LIGHT FIXTURES AND LAMPS WILL BE FURNISHED BY CACHE AND THUMB SCREW VOLUME .CONTROL. (VERIFY EXACT LOCATION IN FIELD). CITY OF TUKWILA BY TENANT'S CONTRACTOR, UNLESS OTHERWISE NOTED. CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING, STORING, MAY 0 6 2013 PROTECTING FROM THEFT, BREAKAGE, ETC, AFTER SIGNING FOR PERMIT CENTER DATE; 3.26.2013 >.I O B N O : DRAWN: CHECKED: T! 1 I i i! E I M °? U Lc) 8897 CORTLAND MORGAN STATE OF WASHINGTON SOUTHCENTER MALL SPACE #640 co oTE5 OD Q REFLECTED CEILING PLAN D -4a u' EXISTING MALL'S BULKHEAD EXISTING MALL NEUTRAL PIER —> 3/4" BLACK METAL NEUTRAL CHANNEL 0 NEUTRAL PIER (ALL SIDES) 3 3/4"W GYP. BD HEADER. WALLCOVER ® SIDES, TYP'. CACHE' LOGO, LIGHT OXIDIZED BRONZE W/HORIZONTAL GRAIN, 5/8' DEEP RETURNS, NON ILLUMINATED SIGN, PIN MOUNTED TO HORIZONTAL BAND. (SIGN CONTRACTOR TO SUBMft SHOP DWG. TO LANDLORD FOR APPROVAL MD FOR SIGNAGE PERMIT PRIOR TO FABRICATION.) 1/2" CLEAR TEMPERED GLASS PANELS EXISITING STOREFRONT ENTRY ELEVATION. 1/2" =1'—O" ft EXISTING STOREFRONT TO REMAIN CLEAN & REPAIR ANY DAMAGED BREAK METAL G.C. TO SUBMIT SHOP DRAWINGS AND FINISH SAMPLES TO ARCHITECT & LANDLORD FOR APPROVAL. 32'-0" 1/2" CLEAR TEMPERED CLASS PANELS ALL STOREFRONT CONSTRUCTION SHALL BE "SELF SUPPORTING" FROM THE FLOOR & INDEPENDANT FROM THE MALL FASCIA, BUT MAY BE BRACED FROM THE MALL STRUCTURE FOR LATERAL SUPPORT ONLY. ALL STOREFRONT CONSTRUCTION SHALL BE CONSTRUCTED OF NON—COMBUSTIBLE MATERIALS. FIELD VERIFY ALL EXISTING CONDITIONS & REPORT ALL DISCREPANCIES TO ARCHITECT BLADE SIGN LOCATION VERIFY W/ MALL EXISTING VERTICAL BUILD—OUT WI DARK BRONZE BREAK METAL ON EXTERIOR FACING 3 3/4"W GYP. BD HEADER, WALLCOVER 0 SIDES, TYP. �s IEV• ED FOR CODE COMPLIANCE a ; pr: %VED Iv:( 13 2013 C;ty oaf Tukwila 2 i°L. `iNG DIVISION RECEIVED CITY OF TUKWILA APR 182013 PERMIT CENTER 3.26.2013 711 iii 8897 n IP I 0 qsr w 0 00 < co EL J- O) Ell J a Q MQ CC J Z W 0 coO GISTERED ARCHITECT CDR NAND MORGAN STATE OF WASHINGTON STOREFRONT PLAN & ELEVATIONS IMINEERIMINEMMMIMINE ID -5 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 13 2013 City of Tukwila BUILDING DIVISION XISTING DECK ABOVE 2ND FLR CLG EXISTING METAL DECKING. EXISTING STRUCTURE — BAR JOISTS NEW 3-5/8" METAL 20 GA TRACK TO RUN WITH—IN THE EXISTING 'OPEN' RIBS OF DECKING AND RESTING ON TOP OF EXISTING BAR JOISTS, PROVIDED AND INSTALLED BY FRAMING SUB—CONTRACTOR. MTL STUD (RUNNER) ATTACHMENT DETAIL EXISTING DECK ABOVE FOR SUSPENDED GYP CLGS NEW 3-5/8" METAL 20 GA STUDS VERT., CONNECTED TO NEW METAL STUDS ABOVE WITH (4) 18 TEK SCREWS. PROVIDED AND INSTALLED BY FRAMING SUB—CONTRACTOR. LOW. 'CGwts' 4143•LL. kP :Yfa:C.'g. . OIi. f1.1.t+ 1114 AI(L PiAk44.1.4 04mA miaow *4 tkcorr SK-S 'VL7r T.TT 3 Yew[ Tttd 'i c B+icLa;T T Ird£ IAA,*( 6E 1 X�'Vy�v. T%o. P ?'f. t i mo, d1L11'Ui toetatt �)CYtia4 >;IEr e tM2ILT X411.17.. (G GtiEERAPP'Cutp IItip FIAT 411 , i P441{(1 moP A- 0 +EXT",. . �4. % k°C7R i'rf ut FQ'its wi.r+10 ftRi'Wt§;P CANt,,475". +a.4 O.t, fi i : I'.$ 4tK UR AsiNshRq.. WYy Q'L 1!f{tlV4E6 & 000;0LILA GAGE ': OE DETAIL— SUSPENDED T—BAR CEILING (STOCK ROOM ONLY) *Fiturr 3 C 3, 5/8", 20 GA. METAL STUD (RUNNER) BETWEEN EXISTING STEEL JOIST & EXISTING METAL DECK PROVIDED & INSTALLED BY FRAMING SUB—CONTRACTOR 3 5/8", 20 GA. METAL STUDS ® 15" O.C. , UP TO RUNNER IN DECK, PROVIDED & INSTALLED BY FRAMING--- SUB—CONTRACTOR,' Liarkg C wadi; i; tAitt At isq.l'r C'L •tIttE' •J 1+L' t4t4 it -4i+cii'if f C,R Lodepiri 0t0 ttt4V` 4 W6t+ 7 "'Avid*,t.ku4iirof+»LtA4LT.r440:'..i. 1.11D O' TAW E43iPmE+:Y (aiR I•.t C' ,. too 44♦0r:i WVTf:+um. �+K'ca*to �1iw.t0,i '11,40eL Vault, !kart 17607401441 I.•ar Ms SPA�1. DIIN0TIOI. +. K411.111. c *I ti to +.44 aa.ErsVI .ay TiLB wWaikc (utt68. 3 4iigf,.8 oR01.4,>t0r 1"ixt'4260+.rtrc. BE bites OtAIPfuu.y ftSPFW4t1.0,-,tapo #r UAW if/J3d s IQ.i, uksLd?A c lacsor'irovin 5/8" TYPE 'X' GYP. BD. PROVIDED & INSTALLED BY FRAMING SUB—CON TRACTOR 3 5/B", 20 GA. METAL STUDS GI 16' O.C., PROVIDED & INSTALLED BY FRAMING SUB—CONTRACTOR li**4 • I IP -0 2-#8 TEK SCREWS AT EACH INTERSECTION PY FRAMING & INSTN FRAMING SUB—CONTRACTOR CEILING SUB—CONTRACTOR NOTE: PROVIDE LATERAL BRACING AT ANY CHANCE IN \ CEILING PLANE. USE 3 5/ ', 20 CA. METAL STUD FOR ATERAL BRACING EVERY 4'-0* \ USE SELFLTAPPING SC.1ERA5 TO PREVENT SUPPING OF EACH (ULSTER AT RUNNER. 3 5/8', 20 GA. METAL LATERAL BRACE ® 48' O.C. TO NEW RUNNER IN DECK, PROVIDED & INSTALLED BY FRAMING SUB—CONTRACTOR 3 5/8", L0 GA. METAL STUD STIFF BACK IN MIDDLE OF AREA PROVIDED & INSTALLED BY FRAMING SUB—CONTRACTOR ODETAIL— SUSPENDED GYP. CEILING sc,LEC1.T.S. tI) �3. 122.. RECEIVED CITY OF TUKWILA APR 182013 PERMIT CENTER 3.26.2013 U 8897 • SOUTHCENTER MALL SPACE 4P640 co co Qir' EGISTERED ARCHITECT CORTLAND MORGAN STATE Of WASHINGTON STOREFRONT DETAILS ID -6 PICT)1 CONTINUE WC2 WALLCOVERING AROUND CORNER AND WRAP ALL. SIDES OF VALANCE, TYP. RAILROAD WALLCOVERING PATTERN ALONG VALANCE i, z,• • /&, //,;-//—/: // 7 //, /7.-/ /,* If ELEVATION 1/4" =11-0" • • B1 FULLY SECURE MIRROR W/ TWO SET OF CONTINUE WC2 WALLCOVERING STEEL CLEATS (TOP & BOTTOM) AROUND CORNER AND WRAP ALLSIDES OF VALANCE, TYP. PROVIDE BLOCKING TO SUPPORT UP TO 300 LBS. 7,;(.4" ; 7.4."" /Z" ,;'4xX Xif/ ;.;:?;;',....7";:" X.47 /..4( :,•;:e"!,',.;%.X;;:17/7 X ; .4' ;,:v" ;,02",v;, • or) 3'-6 • • • RAILROAD WALLCOVERING PATTERN ALONG VALANCE. V,(S_, ,11/ % "1/V1 .• • 2,11- % 1' 1 2 /1'. %. 11. ,/ /1/1' %1%1/1•11. ://>./ %,•", 'A 7/1 /1' SIM • II \ v 1 \:\ OPEN TO F Al THR ENAG MOUNT DRAPERY 11E BACKS HORIZONTAL (DO NOT ANGLE) NOTE ALL CEIUNG FINISHES TO BE PT2 UNLESS OTHERWISE NOTED ELEVATION 1/4" = F1 CASH WRAP EXISTING STOREFRONT CLEAN & REPAIR AS REQUIRED. .• „....,1// 1,,X.XX 1!/,,/,.// 1../- /1/ ...X./if XX/ '„ • 4 !;',..",./„/X1',./.7.:(1- 11,../111,/,/X •./y v,,v; !,!.-;e7 ; V‘, \ , r___ RE,E,,7E.FoR CODE COMPLIANCE APPROVED MAY 1 3 2013 City of Tukwila BUILDING DIVISION vv. ,vvvx v WC2 —RAILROAD (HORIZONTAL) INSTALL WC2 — STANDARD INSTALL WC4 MTL4 — BREAK METAL ELEVATION 3 1/4.. 0 r -o. FULLY SECURE MIRROR W/ TWO SET OF STEEL CLEATS (TOP & BOTTOM) PROVIDE BLOCKING TO SUPPORT UP TO 300 LBS. M3 ‘(ir) TYP. M2: LIGHTED, HINGED TRIPLE MIRROR UNIT ELEVATION 1/4" FULLY SECURE MIRROR W/ TWO SET OF STEEL CLEATS (TOP & BOTTOM) PROVIDE BLOCKING TO SUPPORT UP TO 300 LBS. 01 • M1 BACK—UT FRAMED MIRROR ELEVATION 1/4- = B1 B1 ELEVATION 1/4" =• 1'-0" BI Cp_FI)—to ELEVATION 1/4" = 1'-0" (PT1) r ELEVATION 1/4" = 1.-o. I 21-1-4'11 ! I c) TYP. t ELEVATION 1/4" = 1'-0" TYP. NOTE:PROV1DE BLOCKING FOR ALL MIRRORS TO SUPPORT UP TO 300 LBS. —4- a M1 BACK—LIT FRAMED MIRROR ELEVATION 1/4" mr. TYPICAL FITTING ROOM ELEVATI ON 1/4" = V-0" ELEVATI ON 1/4" = 1'-0" ELEVATI ON 1/4. = B1 INDICATES BLOCKING FOR SECURING ADA COMPA1113LE BENCH %V2 G.C. TO INSTALL ONE TYPE HI HOOK AT THIS LOCATION — +3'-0" AFF ELEVATI ON 1/4" = 1'-0° ELEVATI ON 1/4" = ADA FITTING ROOM REGEIV 3.26.2013 vv : • /1,;!! 'r!!!;',..;.! 1 0 „ 1!!....!!' ) Z5 !! !!'!: ,!!!!!! 1,!!!!•:-!!!1 '(I!!!!?1•!, !!`;! CITY OF TUKWILA APR 1 8 2013 PERMIT CENTER 8897 0 00 < g3 cc _1 w 0 0 ISTERED RCHITECT CORTLAND MORGAN STAT k OF WASHINGTON MOSIMININNIMILIMEMIEWEIN INTERIOR ELEVATIONS & FINISH SCHEDULE ID -7 Mv,r'' ^ }T.5AT kyi , V liq!ll 911' ITEM MANUFACTURER SPECIFICATION Color Source DESCRIPTION LOCATION NOTE FLAMIBILITY PT1 Wolf gordon Scuffmaster tough white collection G 7115707 steven korn (800) 347-0550 X 886 provided by G.C. specialty PAINT walls 9 DAY LEAD TIME class A ASTM E -84-91a PT2 BENJAMIN MOORE SUPER SPEC GREEN SPEC ZERO V.O.C. LATEX PAINT • super white Anna Lehman, (786) 256-0794 BENJAMIN MOORE FLAT PAINT CEILINGS CLASS A WC1 Maya Romanoff stiched vertical MR -SV -X-15-0 provided by owner 30" wide wallcovering not used NOT USED class A ASTM E-84 WC2 Maya Romanoff stiched 11 type vinyl metalic white provided by owner 20 oz. 54" wide wallcovering wall & valance •class A ASTM E-84 WC3 NOT USED N/A WC4 Canegie Fabrics Xorel Damask emboss 6635 paper backed w138 provided by owner 52" wallcovering columns class A ASTM E-84 WC5 Eykon Wallcovering Brio ,Canton A119-524 provided by owner 54" Type II wallcovering walls ' class A ASTM E-84 DF2 Knoll Textiles chic silverlight provided by owner 54" fabric drapery treated by American Flamecoat to pass NFPA 701 B1 Johnsonite MW -66-A 66 -either ore provided by G.C. 4.5" wall base front of house walls class A ASTM E-84 B2 Johnsonite wall base vinyl 20- charcoal provided by G.C. 4" wall base • back of house walls class A ASTM E-84 Cl Constantine sendal C469108 broadloom carpet 108 granite shadow provided by owner 12bolt broadloom fitting areas •253 CLASS I, ASTM E 648-06, NFPA C2 Chilewich Contract BASKETWEAVE PLATINUM provided by owner 56" ROLL cash wrap CLASS I, ASTM E 648-06, NFPA 254 C2a ENCORE INTERNATIONAL UNDERLAYMENT QTSCU provided by G.C. •cash wrap CLASS I, ASTM E 648-06, NFPA 254 Ti Porcelanosa estaurario blanco p14590481 G -P061 blanco /gloss finish provided by owner 24"x 24" x 1/2' thick porcelain tile sales area C.O.F..Grout: Latricrete #88 Color: Silver Shadow N/A T2 Design Works Iris us, Brush Stroke Walnut Stroke V2 provided by owner 12 x 24" x 1/2 thick porcelain tile sales area entry C.O.F. Grout : Laticrete #35 Color Mocha N/A VT1 Armstong imperial texture standard Excelon 51941 polar white provided by G.C. 12 x12" VCT back of house areas CLASS A PL1 Formica color core 7223c-90, polished finish 7223c-90 provided by owner cash wrap • CLASS A MTL1 satin stainless steel #4 metal finish N/A MTL2 buffed bronze metal finish N/A MTL3 Stylmark #110304 w/ base #410443 natural buffed alum. provided by owner metal end cap, 2-1/4" wide extruded aluminum endcap. from 1/2" AFF to underside of drywall at 7-6" N/A MTL4 Kawneer Permanodic anodized finishes dark bronze No. 40 dark bronze No. 40 provided by G.C. AA-M12C22A44 Storefront CLASS A W1 6" wide MDF trim w/ plywood blocking painted to match PL1 finish provided by millworker, installed • by G.C. PLYWOOD TO BE FIRE TREATED CLASS A ACT1 Armstrong #895 minaboard /firegaurd fissured white provided by G.C. 24"x48x 5/8 lay -in panels, with white Tee grid suspension system . back of house Fire rated UL label 1 hour V*411E.. . iiiimik, I 411"I 41°N 8897 0 00 < g3 cc _1 w 0 0 ISTERED RCHITECT CORTLAND MORGAN STAT k OF WASHINGTON MOSIMININNIMILIMEMIEWEIN INTERIOR ELEVATIONS & FINISH SCHEDULE ID -7 2'-1;" 2'-10}' NTS 14-10" l V 1 f_ GYP. BD, PAINT BOT. OF DECK ABOVE MAIN SUSPENSION SYSTEM AS MANUFACTURED BY USG INTERIORS "RIGID X - DONN SUSPENSION SYSTEM" OR EQUAL SECURED TO BOT. BOT OF STRUCTURE ABOVE W/ VERTICAL HANGER WIRE(9 GA) 10'-0 AFF CEILING 5/8" TYPE "X" "LIGHTOLIER" CMH LAMP HOLDER ON CONT. CLG MTD TRACK / 2 1/2" (20 GA) METAL ,' STUD FRAMING GYP. BD. `W/ PAINT FINISH FACE -OF EXISTING DEMISING FRAMING 5/8" TYPE 'X" GYP. WALLCOVERING 1/2" TYPE 'X' GYP W/ PAINT FINISH 1/2" SQ METAL CHANNEL REVEAL, "PITTCON" STR-' _ 6-050, PAINT FINISH 421) 2 1/4" x 1/2' EXTRUDED ALUMINUM ENDCAP FROM +3" AFF TO UNDERSIDE OF DRYWALL HEADER AT +7'-6" AFF, "STYLMARK" #110304 W/ BASE 4410443, NATURAL BUFFED BRITE FINISH. BASE SECTION 5/8" TYPE 'X' GYP. BD. W/ PAINT FINISH 5/8" TYPE 'X' GYP. BD. W/ PAINT FINISH 2 1/2" METAL STUD (20 GA.) FRAMING BASE(if) CARPET —71 IIIIIUIIAlILUpII IND UUIIUpUU.IIIaUIlUllU1 R SECTION 3" 5/8" TYPE 'X' GYP. BD. W/ PAINT FINISH 5/8" TYPE 'X' GYP. BD. W/ WALLCOVER (FINISH VARIES, REFER TO ID -4 FOR WALL COVER LOCATIONS) BASE (1I r- CARPET IlkUINC[101 wuauuuhuaaiuuauuwnu44101u: STAGGERED DOUBLE TUBE FLUORESCENT, LIGHT FIXT., TYPE F • co 1'-10" 2'-104" NTS — ‘r —1r BOT. OF DECK ABOVE MAIN SUSPENSION SYSTEM AS MANUFACTURED BY - USG INTERIORS "RIGID X — DONN SUSPENSION SYSTEM" OR EQUAL SECURED TO BOT. BOT OF STRUCTURE ABOVE W/ VERTICAL HANGER IMRE (9 GA) 5/8" TYPE "X" GYP. BD. PAINT "UGHTOLJER" CMH LAMP HOLDER ON CONT. CLG MTD TRACK 2 1/2" (20 GA) METAL STUD FRAMING 2'-6" 1'-10" ro 5/8" TYPE'l'X" GYPSUM BOARD FABRIC PANEL 5/8" TYPE 'X" GYP. BD, WALLCOVERING m COLOR CORE LAMINA PL1 AT SHELF i 4" SENSI—TILE FRAME COLOR CORE LAMINATE AT CONTIN. ENCLOSURE COLOR CORE LAMINATE COUNTER SECTION 1" = 1'-0" WHITE MELAMINE LAMINATE AT INTERIOR SURFACES COLOR CORE LAMINATE AT BASE P.O.S. ®ACK COUNTER NOTE: NO ATTACHMENT OF NEW STRUCTURE / FRAMING TO EXIST. DECK. NO ADDITIONAL STRUCT. LOADS TO EXIST. BULKHEAD. NOTE: SEE ID -3, REFER TO CHART FOR STUD GAUGES / SPECIFICATIONS BY STUD LENGTH. SURFACE MOUNTED DOUBLE CURTAIN TRACK +10'-0" AFF 5/8 TYPE 'X' GYP. BD. W/ PAINT FINISH DETAIL 3"e 1'-0 EL _ 5/8" TYPE 'X' GYP. BD. W/ PAINT FINISH WOOD TRIM FABRIC CURTAIN 5/8" TYPE 'X' GYP. BD. W/ PAINT FINISH 4j � BASE DETAIL 3' = 1'-0' FINISHED FLOOR F (TYPE VARIES) 1/2" TYPE 'X' GYP W/ PAINT FINISH 1" METAL CHANNEL (25 GA.) FRAMING ALL BASE TO BE MITER CUT & CAULKED. CAULKING SUPPLIED BY MILLWORK CONTRACTOR, COLOR TO MATCH "BENJAMIN MOORE" LINEN WHITE. ALL BASE TO BE APPUED AFB INSTALLATION OF PERIMETER HANGING FIXTURES. RECTIFIED PORCELAIN CERAMIC TILE ON THIN SET INSTALLATION DETAIL 3" = 1'-0" FINISH AT BASE FLATO TAPE & SPACKLEMINUM OVER TED FIN & PAINT ATCHLL 3/41.14" x 1/2" WAALU. BASEFACE "PITTCON" REVEAL, PAINT OF FINISHAPER mmolmo,l mmmm umni® EXIST'G GYP. BOARD DEMISING WALL / BUILD—OUT, PAINT 0 1/2" SQ METAL CHANNEL REVEAL, "PITTCON" STR— . 0-050, PAINT FINISH C` FINISH AT REVEAL FLAT TAPE & SPACKLE OVER FACE OF TAPERED FIN & PAINT TO MATCH WALL. 1/2" TYPE 'X' GYP W/ PAINT FINISH m. 1" FIRE RATED MDF. r� INDICATES DRYWALL HEADER ABOVE, BOT. AT +7'-6"AFF 2 1/4" x 1/2" EXTRUDED ALUMINUM ENDCAP FROM +3/4" AFF TO UNDERSIDE OF DRYWALL HEADER AT +7'-6" AFF, "STYLMARK" #110304 W/ BASE #410443, NATURAL BUFFED BRITE FINISH. lr ALL PANELS, DIVIDERS, WOOD FILLERS, ETC. NOTED AS SUPPLIED & PRIMED BY CABINETRY CONTRACTOR TO BE FIELD FINISHED BY ONSITE MILLWORK CONTRACTOR. ALUMINUM TRIM DETAIL HALF SCALE 5/8" TYPE 'X' GYP. BD. W/ PAINT FINISH 4 2 1—FIN. FLOOR FITTING ROOMS 1/2" PLYWOOD BLOCKING CLEAT 5/8" TYPE 'X' GYP. BD. W/ FINISH AS SCHEDULED BASE ago 3 5/8" METAL STUD (20 GA.) FRAMING 6" 1 L 6"W MDF TRIM, till! PAINT TO MATCH PLAS. LAMINATE (PL1 SALES FLOOR DETAIL 3"=1=0"_ 2 1/2" METAL STUD (20 GA.) FRAMING 6"W MDF TRIM, PAINT TO MATCH PLAS. LAMINATE BASE FINISH: SE ELEVATION BASE / w SAM _1 STAGGERED T5 DOUBLE TUBE FLUOR. LIGHT FIXT, TYPE F +8'-4" AFF TOP OF FIXTURE SECURE BRASS HANGING FIXTURE TO INSIDE FACE OF VALANCE. BLOCKING AS SHOWN. O 5/8" TYPE 'X' GYP. BD. W/ PAINT FINISH 3 V8", 20 MEAL STUD STIFF BACK IN MIDDLE OF AREA CHANNEL @ 16" O.C. , PROVIDED & INSTALLED BY FRAMING SUB—CONTRACTOR DETAIL N.T.S. 3 5/8", 20 GA. METAL STU ATTACHED TO WALL 5/8" TYPE 'X' GYP.BD. PROVIDED & INSTALLED BY SUB—CONTRACTOR WALL — SEE FLOOR PLAN FOR TYPE 2—#8 TEK SCREWS @ 48" O.C. PROVIDED & INSTALLED BY FRAMING SUB—CONTRACTOR 2 #8 TEK SCREWS 0 16" 0.C. PROVIDED & INSTALLED BY FRAMING SUB -CONTRACTOR GYP. BD. SCREW © 12" O.C. PROVIDED & INSTALLED BY FRAMING SUB—CONTRACTOR 3 5/8", 20 GA. METAL STUDS ® 16" 0.C. CHANNEL @ 16" O.C. , PROVIDED & INSTALLED BY FRAMING SUB—CONTRACTOR FRAMING DETAIL - INTERFACE WALL & SUSPENDED GYP. BD. N.T.S. BASE —5/8" TYPE 'X' GYP. BD. W/ PAINT FINISH 1/2" PLYWOOD BLOCKING CLEAT 5/8" TYPE 'X GYP. BD, WALLCOVERING 2 1/2" METAL STUD (20 GA.) FRAMING INDICATES AREA WHERE BLOCKING IS REQUIRED. COORDINATE WITH SHEET ID -4 FOR LOCATIONS. SHOWN HERE FOR PERIMETER FIXTURE ATTACHMENT TO BACK FACE OF VALANCE (TYP) CLEAN UNE LEVEL FINISH TO TERMINATE WALL COVERING I. 3.26.2013 i1.;'A REVIEWED FOR ODE COMPLIANCE APPROVEf MAY 1 3 2013 City of Tukwila BUILDING D M & 0 3i22 RECEIVED CITY OF TUKWILA APR 18 2013 PERMIT CENTER 5897 SOUTHCENTER MALL SPACE 1640 ISTERED CHITEC'T CORTLAND MORGAN STATE OF WASHINGTON INTERIOR SECTIONS & DETAILS ID -8