Loading...
HomeMy WebLinkAboutPermit D13-130 - WOLDAI & GHEBREAB RESIDENCE - REMODELWOLDAI & GHEBREAB RESIDENCE 4735 S 107 ST D13-130 City Si/Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.:: 5476800122 Address: 4735 S 107 ST TUKW Suite No: Project Name: WOLDAI & GHEBREAB RESIDENCE Permit Number: D13-130 Issue Date: 05/08/2013 Permit Expires On: 11/04/2013 Owner: Name: WOLDAI SOLOMON G+SENAIT GHEBREAB Address: 4735 S 107TH ST , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: S K M CONSTRUCTION INC Address: 14415 SE 143 PL , RENTON, WA 98059 Contractor License No: SKMCOI*052L3 Lender: Name: SELF FUNDED - KING COUNTY AIRPORT Address: Phone: 206-296-7437 Phone: 425 235-5569 Expiration Date: 12/30/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSXCAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $44,378.00 Fees Collected: $1,460.87 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT **continued on next page** doc: IBC -7/10 D13-130 Printed: 05-08-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read an governing this work will be complie N N N Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Date: Public: Non -Profit: N Public: ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pre construction or the performance of work. to this permi Signature: Print Name: e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit and agree to the conditions attached .t ' U r% - Date: 5N/( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D13-130 Printed: 05-08-2013 this requirement. • • 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D13-130 Printed: 05-08-2013 • CITY OF TUKWILA Community Development Department Public Works Deparhnent Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.c.i.tukwila.wa.us Building Permit No. R---- l 3 0 Mechanical Permit No. M. (3— a .7 9 Plumbing/Gas Permit No. Public Works Permit No. • Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 5476800122 Site Address: 4735 S. 107th St. Tenant Name: Suite Number: Floor: Property Owners Name: Solomon Woldai and Senait Ghebreab Mailing Address: 4735 S. 107th St. New Tenant: 0 Yes ® ..No Tukwila WA 98178 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296-7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker@kingcounty.gov City State Fax Number: (206) 269-7315 Zip GENERAL CONTRACTOR INFORMATION — (Cointractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: FRCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Jesse Holgate or Timothy Fenlason E -Mail Address: jesse@smstemper.com/tfenlason@jonespayne.ccd City State Day Telephone: (206) 624-2777 Fax Number: (206) 624-2973 Zip NEGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H: A,plications\Forms-Applications On Line\2009 Applications\I-2009 - Permit Application.doc Revised: 1-2009 bh City State Zip Day Telephone: Fax Number: Page 1 of 6 • • BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $12°F1/9"11. 7 ti7 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? 0 Yes ®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On Line\2009 Applications\1-2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l St Floor 2"' Floor 1528 3" Floor 450 Floors thru Basement 1528 Accessory Structure* Attai•hed Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On Line\2009 Applications\1-2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 • • PERMIT APPLICATION NOTES —Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). [ HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 Sigr..ature: Print Name: y J. enlason, SM Stemper Architects, PLLC Date: y1Z41/3 Day Telephone: (206) 624-2777 Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 City State Zip Date Application Accepted: Date Application Expires: Staff Initials:dee H:Ap,hcanons\Fonms-Applications On Line\2009 Applications \I-2009 - Permit Apphcanon.doc Revist d: 1-2009 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 5476800122 Permit Number: D13-130 Address: 4735 S 107 ST TUKW Status: APPROVED Suite No: Applied Date: 04/26/2013 Applicant: WOLDAI & GHEBREAB RESIDENCE Issue Date: Receipt No.: R13-01546 Payment Amount: $1,460.87 Initials: WER Payment Date: 05/08/2013 09:37 AM User ID: 1655 Balance: $0.00 Payee: PAM KUEHL (PHONE) TRANSACTION LIST: Type Method Descriptio Amount Fayment Credit Crd VISA Authorization No. 051970 ACCOUNT ITEM LIST: Description 1,460.87 Account Code Current Pmts EUILDING - RES FLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $1,460.87 882.65 573.72 4.50 o.:......1. AG AO 9A1.1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Prop jeer: L n *; (2 D6,Re_Ac L Type Inspection: Jy ` .. f— 1• Ad s! J C i V ! ri y- Dat led r l �2 � Special Instructions: Date Wanted: "'aim? S— t00r p.m. Requester: Phone No. No. 1S-' 2-'2- >;% Approved per applicable codes. Corrections required prior to approval. 3 COMMENTS: f)!,fV i A; Diap n� svIA .'3/ l k1 Inspector: Dat f U • n REINSPECTION FEE REQUIRED. Pr or to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. - PEW' CO PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-130 DATE: 04-26-13 PROJECT NAME: WOLDAI _& GHEBREAB RESIDENCE SITE ADDRESS: 4735 S 107 ST X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision '# After Permit Issued DEPARTMENTS*�&vt` Bilding ivision Fire Prevention Public Works ❑ Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 04-30-13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route1)4 Structural Review Required No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: DUE DATE: 05-28-13 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Per Friendly Page 1 General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name S K M CONSTRUCTION INC UBI No. 601577401 Phone 4252355569 Status Active Address 14415 Se 143Rd Pl License No. SKMCOI.052L3 Suite/Apt. License Type Construction Contractor City Renton State WA Zip 98059 County King Business Type Corporation Parent Company Effective Date 6/23/1995 Expiration Date 12/30/2013 Suspend Date Specialty 1 General Specialty 2 Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SKMC0"093L6 S K M CONSTRUCTION Construction Contractor General Unused 6/26/1991 6/17/1995 Archived SKMINI.976QL S K M INDUSTRIES INC Construction Contractor General Unused 11/13/2003 12/6/2009 Expired Business Owner Information Name Role Effective Date Expiration Date MORRISON, SHEILA K President 06/23/1995 Bond Amount MARKET SANDERS Agent 06/23/1995 06/25/2001 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 FIRST NATL INS CO OF AMERICA 6695979 06/17/2010 Until Cancelled $12,000.00 04/26/2010 4 DEVELOPERS SURETY Et INDEM CO 188889C 12/30/2001 Until Cancelled 08/01/2010 $12,000.0012/05/2001 08/18/2011 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 16 James River Ins 000495931 08/21/2012 08/21/2013 $1,000,000.00 08/20/2012 15 James River Ins 00049593 08/21/2011 08/21/2012 $1,000,000.00 08/18/2011 14 COLONY INS CO EPK300402 08/21/2010 08/21/2011 $1,000,000.00 08/20/2010 13 CENTURY SURETY CO CCP616634 08/21/2009 08/21/2010 $1,000,000.0001/20/2010 12 AMERICAN STATES INS CO 01CH6810051 01/25/2009 01/25/2010 $1,000,000.0001/23/2009 11 AMERICAN STATES INS CO 01CH6810051 12/30/2008 01/25/2009 $1,000,000.00 12/23/2008 10 AMERICAN STATES INS CO 01CH6810051 12/30/2007 12/30/2008 $1,000,000.00 12/07/2007 9 AMERICAN STATES INS CO 01CD87273820 12/30/2006 12/30/2007 $1,000,000.00 12/19/2006 littrie•//fnrtracc uua anvil ni/hhin/Print acme. 05/OR/2013 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00784C12 BID PACKAGE M-37 3-53-0058-045 SEPARATE PERMIT REQUIRED FOR 14 ft:hank:el Bectrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE t0:1)DES ALL iNFoi�!'14TiON iN THE DRAWINGS AND SPEGPIGATIONICAL 1511NCLUDiNCs BUT NOTTILATION. THE LIMITED CONTRACT INCLUDES APPLICABLE YES NO 1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL -FRAMED ACOUSTICAL WINDOWS. X 2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X 8. INSTALLATION OF PET DOORS. X 9. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 10. INSTALLATION OF CHIMNEY CAP. X II. REGULATED MATERIALS ABATEMENT. X 12. ATTIC VENT BAFFLES. X 13. INSTALLATION OF ATTIC INSULATION. X 14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AiR UNIT AND ASSOCIATED DUCTING. X 15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 15. INSTALLATION OF SMOKE DETECTORS. X 19. NEW ELECTRICAL PANEL / SERVICE. X 20. KNOB AND TUBE WIRING. X REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan stih-n;tfal andmay include additional plan reviewfcLs. FILE COPY ft No, 113 1210 Plan review approval is Approval of construction the violation of any ., .. , Copy and If to .; one. not authorize or ordnance. Receipt is ed City lb WILDING DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of WA TuK 4q. APPLICABLE CODES: 2009 International Residential Code, International Fire Code, International Mechanical Code 5416800122 ZONING: 5F1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) V B NON SPRINKLERED REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 2 2013 City of Tu wila BUILDIN VISION LEGAL DESCRIPTION: THE NORTH 125 FEET OF LOT 14 AS MEASURED ALONG THE EAST LiNE OF MERRiCK'S ACRE TRACTS DIVISION NO. 2 ADDITION TO THE CITY OF SEATTLE, AS PER PLAT RECORDED IN VOLUME 12 OF PLATS, PAGE 41. RECORDED OF KING COUNTY - EXCEPT THAT PORTION CONVEYED TO KING COUNTY FOR ROAD PURPOSES BY DEED RECORDED UNDER KING COUNTY RECORDING NO. 2449506, SITUATED IN THE CiTY OF 11JKWiLA, COUNTY OF KiNG, STATE OF WASHINGTON. DRAWING INDEX T0.0 TITLE SHEET, PROJECT INFO. A1.0 FLOOR PLANS 4 NOTES A1.1 FLOOR PLANS 4 NOTES 42.0 WINDOW TYPES, SCHEDULE 4 DETAILS 42.1 WINDOW TYPES, SCHEDULE 4 DETAILS 422 DOOR TYPES, SCHEDULE 4 DETAILS 42.3 MISCELLANEOUS DETAILS (f` 42.4 WINDOW FLASHING DETAILS CE1 .0 LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DM INDEX vtd6\ 2.0 MECHANICAL PLANS AND DETAILS .O ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Fh: 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E-mail: SharynParkerekingcountyrgov ARCHITECT: S.M. Stemper Architects PL.L.C. 4000 Delridge Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody LeungE-mail: Jerryesmstemper.com melodyesmstemper.com ACOUSTICAL ENGINEER: SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 831. 0819 Fax: 206.839.0024:. s Contact: Mohamed Alt:,4llaoua E-mail: mohamedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph: 206. 318. 0569 Fax: 206.318.0641 Contact: Dylan Turner E-mail: DylanTegreenbuschcom ELECTRICAL ENGINEER Tres West Engineers 2102 5. 42nd Street, Suite 301 Tacoma, WA 98409 Fh: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E-mail: bcretreswest.com REGULATED MATERIALS: P55 Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206.162.4180 Contact: Tim Ogden E-mail: tim ogdenepbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. 0200 Boston, MA 02114 Contact: Tim Fenlason, Cynthia Maeda E-mail: tfenlasoneJonespayne.com CMaeda eJonespayne.com STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206.. 622. 4580 Fax: 206.622.0422 Contact: Ron Martinson E-mail: ronmepsm-engineers.com VICINITY MAP (NTS) RECEIVE CITY OF TUKWILA APR 2 6 20113 PERMIT CEN -ER 13.13d S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 REGISTERED A-CHITECT OCTOBER 19, 2012 0810.03.2325 F- O rzd Z O z w z z 0 U U Z MPROVEMENTS >- 0 w w w O z LL 0 Ct -JF.- z w 0 w AIP NUMBER 3-53-0058-045 z 0 0 z_ w LL! cn DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP PROJECT INFORMATION, DRAWING INDEX, DIRECTORY T0.0 0810.03.2325 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 2 2013 City of Tukwila BUILDING DIVISION I SPECIAL NOTES: I. LEAD PAINT 15 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 11 01 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. 2. REFERENCE 4/423 FOR SMOKE/ CARBON MONOXIDE DETECTOR INSTALLATION DETAIL. STORAGE OFFICE STUDY BATH STORAGE FUR STUDY 2 LAUNDRY IE (E) /7. INTERIOR SOFFIT FAMILY ROOM /(E) FIREPLACE INSERT PRIOR TO COMMENCING WITH DEMOLITION A "pre -demo inspection" is required. Contractors shall provide documentation that an "asbestos survey" has been completed. If needed, abatement procedures per "Puget Sound Clean Air Agency" shall be completed and documentation of compliance shall be provided at time of final inspection. GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOUNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 FM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 15 ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 FM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS E SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION la INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS 51-IEET. 19. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR TI -IE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 PM. LOWER FLOOR PLAN 1/4" = 1' - 0" PLAN KEYNOTES Oj DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. 02 DEMOLISH EXISTING DOOR(S), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND STORM DOOR REF. DOOR SCHEDULE. 0 O INSTALL SECONDARY SKYLIGHT UNDER (E) SKYLIGHT. MAXIMUM AIR SPACE BETWEEN SKYLIGHTS SHALL BE 4". VERIFY EXISTING CONDITIONS AND NOTIFY TECHNICAL REPRESENTATIVE IF EXISTING CONSTRUCTION DOES NOT ALLOW FOR TI -115. REF. 2/A23 FOR DETAIL. OINSTALL NEW SECONDARY SLIDING DOOR(S). REF. DOOR SCHEDULE. O DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A23 FOR DETAIL. COORDINATE WITH MECHANICAL DOCUMENTS. OINSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS. O DEMOLISH EXISTING DOOR(5), FRAME, CASING, AND THRESHOLD. INSTALL NEW PRIMARY AND SECONDARY SLIDING DOOR(5). REF: DOOR SCHEDULE. REMOVE (E) WINDOW AND REPLACE WITH ACOUSTICAL WINDOW ASSEMBLY. EXISTING WINDOWS NOTED ARE LOCATED IN SLEEPING AREAS (1)1AND DO NOT COMPLY WITH EGRESS REQUIREMENTS. CUT DOWN EXISTING WALL CONSTRUCTION TO COMPLY WITH EGRESS REQUIREMENTS. REPAIR AND FINISH WALL TO MATCH ADJACENT EXISTING CONSTRUCTION. FOR BIDDING PURPOSES, ASSUME WINDOW SIZING FOR EGRESS. REF: WINDOW SCHEDULE ON SHEET 42.0. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. RECEIVED CITY OF TUKWILA APR 2 6 2013 PERMIT CENTER LEGEND A ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR/ STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW A. EAST ELEVATION B. SOUTH ELEVATION C. WEST ELEVATION D. NORTH ELEVATION D 13� 13o 1111111111111 GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL AND UJI-IDLE HOUSE VENT INSTALLATION. REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 r----- ATTIC INSULATION ATTIC INSULATION DAM SD INSTALL BATTERY OPERATED SMOKE DETECTORS SC INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER SOFFIT FOR MECHANICAL DUCTING S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 SCOTT STATE O= TEMPE liASHINGTON OCTOBER 19, 2012 0810.03.2325 O 0 J z 0 > z w z z O U 0 z MPROVEMENTS >- 0 w w w 0 z u_ 0 J z w 0 C1) w r AIP NUMBER 3-53-0058-045 DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES A1 .0 0810.03.2325 DECK ❑2 KITCHEN SPECIAL NOTES: 1. LEAD PAINT 16 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 11 01 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. 2. REFERENCE 4/423 FOR SMOKE/ CARBON MONOXIDE DETECTOR INSTALLATION DETAIL. BEDROOM 2 L! BATT -I DINING ROOM BEDROOM 1 GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WDRK DAILY. 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 16 ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8•.00 AM AND 5:00 PM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 50 AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE AIRE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORD. REFER TO ELECTRICAL FOR TIMER LOCATION 18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AI.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. 19. CONTRACTOR 16 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE ..00 AM. 4 AFTER 5:00 PM. MAIN FLOOR PLAN 1/4"= 1'-0" DECK ffEl LIVING ROOM (E) FIREPLACE INSERT A. EAST ELEVATION REVIEWED VIEWED FOR CODE COMPLIANCE APPROVED MAY 0 2 2013 City of Tukwila ,uILDING DIVISION B. SOUTH ELEVATION PLAN KEYNOTES Oi DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. O DEMOLISH EXISTING DOOR(S), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND 2 STORM DOOR REF. DOOR SCHEDULE. 0 O INSTALL SECONDARY SKYLIGHT UNDER (E) SKYLIGHT. MAXIMUM AIR SPACE BETWEEN SKYLIGHTS SHALL BE 4". VERIFY EXISTING CONDITIONS AND NOTIFY TECHNICAL REPRESENTATIVE IF EXISTING CONSTRUCTION DOES NOT ALLOW FOR 11416. REF. 2/423 FOR DETAIL. OINSTALL NEW SECONDARY SLIDING DOOR(S). REF. DOOR 501-IEDULE. O DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A23 FOR DETAIL. COORDINATE WITH MECHANICAL DOCUMENTS. OINSTALL NEW THEFVOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS. O DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW PRIMARY AND SECONDARY SLIDING DOOR(S). REF: DOOR SCHEDULE. O REMOVE (E) WINDOW AND REPLACE WITH ACOUSTICAL WINDOW ASSEMBLY. EXISTING WINDOWS NOTED ARE LOCATED IN SLEEPING AREAS AND DO NOT COMPLY WITH EGRESS REQUIREMENTS. CUT DOWN EXISTING WALL CONSTRUCTION TO COMPLY WITH EGRESS REQUIREMENTS. REPAIR AND FINISH WALL TO MATCH ADJACENT EXISTING CONSTRUCTION. FOR BIDDING PURPOSES, ASSUME WINDOW SIZING FOR EGRESS. REF: WINDOW SCHEDULE ON 51-IEET 42.0. ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO I-IOMEOU.NER DRIVEWAY. BATT -I 14 l SITTING ROOM C2/‘ UPPER FLOOR PLAN 1 /4 1' - 0" C. WEST ELEVATION LEGEND r I ❑X Nil ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR/ STOR'1 DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW RECEIVED CITY OF TUKWILA APR 2 6 2013 PERMIT CENTER D. NORTH ELEVATION b 13 1111111111111 GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. REF. MECH. d ELECT. REF. GENERAL NOTE 11 r--- ATTIC INSULATION ATTIC INSULATION DAM SD INSTALL BATTERY OPERATED SMOKE DETECTORS SC INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS 'GAS GAS METER SOFFIT FOR MECHANICAL DUCTING S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 REGISTERED A.CHITECT SCOTT TEMPE' STATE 0= VIHSHINGTON OCTOBER 19, 2012 0810.03.2325 O z O z w z ›- 1— C.) — U 0 z AIP NUMBER MPROVEMENTS >- 0 w 2 w r w (/) 0 z U —J 1— z w 0 U) Lu 3-53-0058-045 z 0 z w Q U) DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES A1 . 1 0810.03.2325 WINDOW TYPES I. HORIZONTAL XX SLIDER i 2. CASEMENT/ FIXED/ CASEMENT i 3. FIXED 4. SECONDARY SKYLIGHT (FIXED OR OPERABLE) 5. CASEMENT 6. SLIDER OVER FIXED 1. 8. CASEMENT/ FIXED SLIDER/ FIXED/ SLIDER WINDOW SCHEDULE WIND. NO ROOM LOCATION -.1--- 1. 8. CASEMENT/ FIXED SLIDER/ FIXED/ SLIDER WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS DETAIL SET A BEDROOM 1 8 6' -II" x 1' -II" STAIN/STAIN CUT SILL DOWN 11" FOR EGRESS. (E) SILL HT IS 51" AFF 1/42.0 B BEDROOM 2 I 3'-I0" x 2'-10" STAIN/STAIN SAFETY GLAZING REQUIRED CUT SILL DOWN 8" FOR EGRESS. (E) SILL NT 15 48" AFF I/42.1 C BEDROOM 2 1 3'-10" x 2'-10" STAIN/STAIN SAFETY GLAZING REQUIRED CUT SILL DOWN 8" FOR EGRESS. (E) SILL 1 -IT IS 48" AFF I/42.1 D BEDROOM 2 4 I'-10" x 4'-0" STAIN/STAIN SKYLIGHT, SAFETY GLAZING REQUIRED 2/423 E KITCHEN 2 5'-10" x 3'-10" STAIN/STAIN SAFETY GLAZING REQUIRED 1/42.0 F KITCHEN 2 5'-10" x 3'-10" STAIN/STAIN I/42.0 G KITCHEN 5 2'-9" x 2' -II" STAIN/STAIN 2/A2.I H KITCHEN 4 I'-10" x 4'-0" STAIN/STAIN SKYLIGHT, SAFETY GLAZING REQUIRED 2/423 1 )INING ROOM 6 4'-10" x 4'-4" STAIN/STAIN 1/42.0 J DINING ROOM 2 4' -Il" x 2'-10" STAIN/STAIN SAFETY GLAZING REQUIRED 1/42.0 K LIVING ROOM 2 5' -II" x 3'-I0" STAIN/STAIN SAFETY GLAZING REQUIRED 1/42.0 L LIVING ROOM 2 5'-11" x 3'-10" STAIN/STAIN SAFETY GLAZING REQUIRED 1/42.0 M LIVING ROOM 2 1'-11" x 3'-10" STAIN/STAIN 2/42.0 N SITTING ROOM 5 2'-2" x 2' -II" STAIN/STAIN 1/42.0 O SITTING ROOM 1 4'-11" x 3'-4" STAIN/STAIN 1/42.0 P OFFICE I 2'-10" x I'-11" STAIN/STAIN 1/42.0 Q STUDY I 5'-I0" x 1'-10" STAIN/STAIN 1/42.0 R STUDY 2 I 5'-10" x P -I0" STAIN/STAIN 1/42.0 5 FAMILY ROOM I 5'-I0" x 3'-I0" STAIN/STAIN SAFETY GLAZING REQUIRED 3/42.0 T FAMILY ROOM I 5'-I0" x 3'-10" STAIN/STAIN SAFETY GLAZING REQUIRED 3/A2.0 U FAMILY ROOM 1 3'-10" x 2'-11" STAIN/STAIN SAFETY GLAZING REQUIRED 3/42.0 (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. PRE -PRIMED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY REMOVE (E) WD. SIDING FOR (E) GWB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE /-TOUCH UP PAINT, AS REQ'D CONTINUOUS SEALANT, TYP. INSTALLATION OF NEW WINDOW TRIMS AND REATTACI-IMENT OF (E) SIDING TO WINDOW OPENING LAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING 10 MATCH (E) SIDING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN WINDOW HEAD SOLID WOOD TRIM WD. JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION (E) GWB TOUCH UP PAINT, AS REQ'D WINDOW JAMB TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WD SIDING WINDOW SILL CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT 3/4" WOOD SILL SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. TOUCH UP PAINT, AS REQ'D SELF -ADHERING MEMBRANE (E) GWB WOOD SIDING - WINDOW DETAIL SET 3"=1'-0" (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT. OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING A5 REQ'). MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. PRE -PRIMED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO 8E SELECTED IN 114E FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY REMOVE (E) WD. SIDING FOR 71 III II INSTALLATION OF NEW WINDOW TRIMS AND REATTACHMENT OF (E) SIDING TO WINDOW OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY IREVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 2 2013 City of Tukwila BUILDING DIVISION (E) GWB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE /----TOUCH UP PAINT, AS REQ'D CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WINDOW HEAD W). JAMB LINING SEALANT AND BACKER ROD SHIM AS NECESSARY SELF -ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT AND (E) SILL (E) BRICK VENEER WINDOW JAMB 1 II J II SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION (E) GWB TOUCH UP PAINT, AS REQ'D /4" WINDOW SILL CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD 3/4" WOOD SILL SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. TOUCH UP PAINT, AS REQ'D WOOD SIDING - WINDOW DETAIL SET 3"=1'-0" (E) GWS TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET. SLOPE 1" min. min. L HEMMED EDGE 1 END CLOSURE HEAD FLASHING DETAIL TYP. 3" = 1' - 0" EXISTING MASONRY VENEER SEALANT AND BACKER ROD (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE TOUCH UP PAINT, AS REQ'D CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WOOD LINING SEALANT AND BACKER ROD ACOUSTICAL WINDOW ASSEMBLY (E) EXTERIOR SHEATHING (E) MASONRY VENEER SELF ADHERING MEMBRANE WINDOW HEAD SEALANT AND BACKER ROD -� ACOUSTICAL WINDOW ASSEMBLY SEALANT AND BACKER ROD 514I11 AS NECESSARY SHIM AS NECESSARY FILL GAP W/ BATT INSULATION (E) GLOB TOUCH UP PAINT, A5 REQ'D CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WOOD LINING SEALANT 4 BACKER ROD ACOUSTICAL WINDOW ASSEMBLY RECEIVED WINDOW JAMB CITY OF TUKWILA APR 2 6 2013 PERMIT CENTER /4" SELF -ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT AND (E) SILL (E) BRICK VENEER SEALANT 4 BACKER ROD 3/4" WOOD SILL SOLID WOOD TRIM - CONTINUOUS SEALANT, TYP. TOUCH UP PAINT, A5 REQ'D (E) GWS bvi,130 WINDOW SILL BRICK VENEER SIDING - WINDOW DETAIL SET 3" = 1' - 0" u S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973. 4220 REGISTERED A cHITECT COTT STATE OF OTEMPE SHINCTOK' OCTOBER 19, 2012 0810.03.2325 O 0 J z 0 > z w z z 0 V z MPROVEMENTS >- 0 w w w 0 z IL 0 AIP NUMBER 3-53-0058-045 DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2325 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 2 2013 City of Tukwila BUILDING DIVISION CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF-ADI-IERING MEMBRANE AGAINST SHEATHING:. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF -ADHERING: MEMBRANE. TYP AT 1-IEAD AND JAMB REMOVE (E) SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE -PRIMED, GALV SI-EET METAL FLASHING W END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT (E) GWB / TOUCH UP PAINT, A5 REQ'D �/ CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WD. JAMB LININGS. FINISH TO MATCH (E) SEALANT 4 BACKER ROD CAREFULLY CUT BACK (E) SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST 51-1EATHING. INSTALL SECOND LAYER OF SELF ADHERMG MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR 5HEATHING TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED REPLACEMENT WINDOW ASSEMBLY PER SCHEDULE AND SPECIFICATION BACKER ROD 4 SEALANT REPLACEMENT WINDOW ASSEMBLY PER SCHEDULE AND SPECIFICATION 0 WINDOW HEAD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED REPLACEMENT WINDOW ASSEMBLY FER SCHEDULE AND SPECIFICATION WINDOW JAMB (E) GWB TOUCH UP PAINT, A5 REQ'D CAREFULLY REMOVE (E) SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING IS WINDOW SILL CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM W. JAMB LINING. FINISH TO MATCH (E) SEALANT 4 BACKER ROD BACKER ROD 4 SEALANT 3/4" WD. SILL - STAIN TO MATCH (E) SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. TOUCH UP PAINT, AS REQ'D SELF -ADHERING MEMBRANE (E) GWS BRICK VENEER SIDING - WINDOW DETAIL SET 3"= 1'-0" (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. PRE -PRIMED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY REMOVE (E) WD. SIDING FOR (E) GUMS (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE TOUCH UP PAINT, AS REQ'D CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WD. JAMB LINING INSTALLATION OF NEW WINDOW TRIMS AND REATTACHMENT OF (E) SIDING TO WINDOW OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR 514EATHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW. NAILING FIN WINDOW HEAD SEALANT 514IM A5 NECESSARY FILL GAP W/ BATT INSULATION (E) CERAMIC TILE (E) GLIB WINDOW JAMB CONTINUOUS SEALANT, Tl -P. SOLID WOOD TRIM WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT 3/4" WOOD SILL SOLID WOOD TRIM TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WD SIDING WINDOW SILL SELF -ADHERING MEMBRANE (E) CERAMIC TILE (E) GWB WOOD SIDING - WINDOW DETAIL SET 3"= 1'-0" TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET. SLOPE v E N 1" min. min. HEMMED EDGE J END CLOSURE HEAD FLASHING DETAIL TYP. 3"= 1'-0" Dia- RECEIVED CITY OF TUKWILA APR 2 6 2013 PERMIT CENTER ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206)624-2777 • FAX (206) 824-2973 4220 REGISTERED- AL0HITECT COTT dTEMP STATE OF :ti SHPIGTON" OCTOBER 19, 2012 0810.032325 O 0 J z 0 Q z w E'- z >- z 0 0 0 z MPROVEMENTS >- 0 w w w 0 z U tz AIP NUMBER 3-53-0058-045 SEATTLE WASHINGTON DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.1 0810.03.2325 DOOR TYPES M 81113 ,A FLUSH SCW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT c FLUSH 5CW PRIMARY/ SECONDARY W/ SIX PANELS SLIDING GLASS DOOR W/ OBSERVATION PORT W/ SAFETY GLAZING EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING E EXTERIOR SINGLE LEAF STORM W/ SAFETY GRILLE DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 ENTRY A 3'-0" x 6'-8" STAIN/ STAIN HW -I / 609 DK -4 LOCK -I I/422 2 KITCHEN C 5' -II" x 6'-8" 3/422 3 LIVING ROOM C 5'-11" x 6'-8" 2/422 4 STUDY 2 B 2'-8" x 6'-8" STAIN/ STAIN 1-11U-1 / 609 DK -4 LOCK -I 1/422 5 FAMILY ROOM A 2'-8" x 6'-8" STAIN/ STAIN HW -1 / 609 DK -4 LOCK -I I/422 6 ENTRY D 3'-0" x 6'-S" I/422 1 STUDY 2 E 2'-8" x 6'-8" 1/422 8 FAMILY ROOM D 2'-S" x 6'-8" I/A22 9 KITCHEN (PRIMARY) C 5' -II" x 6'-8" 3/422 (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW DOOR ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. PRE -PRIMED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN TI -IE FIELD CONTINUOUS SEALANT BEI-IIND Z BAR FRAME STOW DOOR PER SCHEDULE 2" MIN. (E) EXTERIOR SHEATHING SELF -ADHERING MEMBRANE TOUCH UP PAINT AS, REQ'D CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM 514IM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE REMOVE (E) WD. SIDING FOR INSTALLATION OF NEW DOOR TRIMS AND REATTACHMENT OF (E) SIDING TO DOOR OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) WOOD SIDING CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE DOOR HEAD (E) EXTERIOR SHEATHING TOUCH UP PAINT, AS REQ'D CONTINUOUS KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER-STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE SILL N HEAD OF SEALANT 2" MIN. DOOR JAMB DOOR SILL SEALANT, TYP. EXISTING FRAMING SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE (Th WOOD SIDING - DOOR DETAIL SET 3"=1'-0" (E) WD. SIDING PRE -PRIMED, GALV 51-IEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD SELF -ADHERING MEMBRANE. TURN DOWN OVER FRONT EDGE OF TRIM. ENSURE NO MEMBRANE 15 VISIBLE BELOW FLASHING EDGE 2X TAPERED CAP REMOVE (E) SIDING TO FACILITATE INSTALLATION OF FLASHING AND DOOR HEAD ASSEMBLY TRIM- PAINT TO MATCH (E) TRIM CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS (E) WALL UNDERLAYMENT DOOR HEAD BACKER ROD AND SEALANT SELF-ADHEARING MEMBRANE TRIM- PAINT TO MATCH (E) TRIM CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM TRIM- PANT TO MATCH (E) TRIM SELF -ADHERING MEMBRANE SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTION5 WD. TRIM BEYOND (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF -ADHERING MEMBRANE REMOVE (E) WO0D SIDING AND REPLACE AS REQ'D. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF PENETRATION FLASHING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. TYP. AT HEAD AND JAMBS • _•�r"r"iJ _440 SOLID WOOD LINING (E) PRIMARY SLIDING DOOR ASSEMBLY. (E) WD. SIDING (E) EXTERIOR SHEATHING LIFT (E) WALL UNDERLAYMENT. LAP NEW UNDERLAYMENT UNDER (E) UNDERLAYMENT 2" AND CONTINUE OVER SLIDING GLASS DOOR FRAME SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS. SEALANT (E) FLOOR/ DECK FRAMING 11 i" MIN. BETWEEN PRIMARY AND SECONDARY SLIDING GLASS DOOR FRAMES DOOR JAMB SOLID WOOD LINING (E) PRIMARY SLIDING GLASS DOOR (E) SLIDING GLASS DOOR (E) FINISH FLOOR (E) INTERIOR CONC. SLAB. OR (E) WD. FLOOR FRAMING DOOR SILL WOOD SIDING - DOOR DETAIL SET 3"=1'-0" (E) WD. SIDING PRE -PRIMED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO EE SELECTED IN THE FIELD SELF -ADHERING MEMBRANE. TURN DOWN OVER FRONT EDGE OF TRIM. ENSURE NO MEMBRANE 15 VISIBLE BELOW FLASHING EDGE 2X TAPERED CAP REMOVE (E) SIDING TO FACILITATE INSTALLATION OF FLASHING AND DOOR HEAD ASSEMBLY TRIM- PAINT TO MATCH (E) TRIM CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS (E) WALL UNDERLAYMENT TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 5. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET. SLOPE I" min. 1/4."`min. HEMMED EDGE END CLOSURE CAHEAD FLASHING DETAIL TYP. 3 -1 -0 DOOR HEAD BACKER ROD AND SEALANT SELF-ADHEARING MEMBRANE TRIM- PAINT TO MATCH (E) TRIM CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF POOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM TRIM- PAINT TO MATCH (E) TRIM SELF -ADHERING MEMBRANE SECONDARY SLIDING STOW DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS WD. TRIM BEYOND SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS. (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF -ADHERING MEMBRANE REMOVE (E) WOOD SIDING AND REPLACE AS REQ'D. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF PENETRATION FLASHING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. TYP. AT HEAD AND JAMBS SOLID WOOD TRIM SOLID WOOD LINING NEW PRIMARY SLIDING GLASS DOOR INSTALL PER MFG'R INSTRUCTIONS (E) WD. SIDING (E) EXTERIOR 51-IEATHING LIFT (E) WALL UNDERLAYMENT. LAP NEW UNDERLAYMENT UNDER (E) UNDERLAYMENT 2" AND CONTINUE OVER SLIDING GLASS DOOR FRAME 11 i" MIN. BETWEEN PRIMARY AND SECONDARY SLIDING GLASS DOOR FRAMES DOOR JAMB SEALANT (E) FLOOR/ DECK FRAMING SOLID WOOD TRIM SOLID WOOD LINING NEW PRIMARY SLIDING GLASS DOOR INSTALL PER MFG'R INSTRUCTIONS NEW PRIMARY SLIDING GLASS DOOR INSTALL PER MFG'R INSTRUCTIONS (E) FINISH FLOOR (E) INTERIOR CONC. SLAB. OR (E) WD. FLOOR FRAMING REVIEWED FOR ODE COMPLIANCE APPROVED MAY 022013 DOOR SILL WOOD SIDING - DOOR DETAIL SET 3"=1'-0" City of Tukwila ILDING DIVISION RECEIVED CITY OF TUKWIL A APR 2 6 2013 PERMIT CENTER ■ S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 REGISTERED A rHITECT COTT idTEMPE° STATE OF • 'SHINCTON'' OCTOBER 19, 2012 0810.03.2325 O 0 J z 0 > z w z z 0 U 0 z AIP NUMBER MPROVEMENTS >- 0 w 2 w 0 z U J z w Lu 3-53-0058-045 z 0 1- 0 z_ w 1- 1 - DATE - DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT Jo PROJECT MANAGER ML&TF DRAWN LB&CP DOOR TYPES, SCHEDULE & DETAILS A2.2 0810.03.2325 EXISTING CEILING STRUCTURE REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 2 2013 City of Tukwila BUILDING DIVISION a INA x1 1 J DUCT/ SOFFIT DETAIL 1-1/2" = 1' - 0" / DUCTS PER PLAN WITHIN SOFFIT RE: MECHANICAL 2x2 CONT. NAILER %" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL (E) WD FRAME WALL ASSEMBLY CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT NEAR AND JAMBS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF VENT FIXTURE AND FLASHING. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. PRE -PRIMED, GALV. 51-EET METAL FLASHING W/ FF. END CAPS UNDER SELF -ADHERING MEMBRANE. EXTEND FLASHING 4" UP WALL. PAINT COLOR TO BE SELECTED IN THE FIELD PAINT VENTILATION HOOD, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION HOOD. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. REMOVE / REPLACE (E) SIDING AS REQUIRED. (E) WALL UNDERLAYMENT SELF -ADHERING MEMBRANE (E) EXTERIOR SHEATHING 2X BLOCKING 2X2 CONTINUOUS PRESSURE TREATED BLOCKING, 4 SIDES AIR INTAKE DETAIL AT EXTERIOR 3"= 1'-0" 2X WD LEDGER, TYP. SEALANT, ALL SIDES 2X WD FRAME W/ 2X BLOCKING EXIST. SKYLIGHT CONSTRUCTION MITERED CORNERS MATCH (E) ADJACENT FINISH WOOD STOP, TYP. CASEMENT LATCH SECONDARY SKYLIGHT DETAIL 1 1/2"= 1'-0" CEILING 4" MIN NOTE: REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. z EXIST. CEILING 1/4" TEMPERED GLASS SIDE WALL DETECTOR INSTALLATION DETAIL TYP. 3"= 1'-0" 13-13t) RECEIVED CITY OF TUKWILA APR 2 6 2013 PERMIT CENTER ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 REGISTERED - AL HiTECT 1r# COU 4TEMP • STATE Or SHINGTON OCTOBER 19, 2012 0810.03.2325 F -- O 0 >- J 0 Q W z O w z w O �- z U O U < (� J Z Q Z w 0 w MPROVEMENTS AIP NUMBER 3-53-0058-045 Z 0 CD z Lu Q DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP MISC. DETAILS A2.3 0810.03.2325 LIFT (E) WALL UNDERLAYMENT AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 12" LAP SILL MEMBRANE FLASHING 2-I/2" OVER (E) BLDG. PAPER AT SILL. EXTEND 12 BEYOND RO. AT EA. END OF SILL. (E) WALL (E) SHEATHING CUT SILL FLASHING TO EDGE OF RO. A5 SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING I" MIN UNDERLAYMENT AT SILL MEMBRANE FLASHING AT SILL 4 BUTTERFLY CORNER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1-1A5 BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE N SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT 51-1OULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) WALL UNDERLAYMENT AT SILL. O ' 0 0 0 0 0 0 0 0 0 0 ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING REMOVED SCALE: NTS EDGE OF (E) SIDING, SHOWN D I AGRAMAT ICAL L Y. (E) SIDING NOT 5HOWN FOR CLARITY. LAY (E) WALL UNDERLAYMENT BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D (E) SIDING NOT 51-1OWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1-1A5 BEEN INSTALLED. r 7 WHERE REQUIRED, TRIM (E) WALL UNDERLAYMENT At HEAD TO PREPARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW TRIM (FOLLOWING STEPS). L J HEAD FLASHING PREPARATION SCALE: NTS (E) WALL UNDERLAYMENT NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SI -1011N FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1-1A5 BEEN INSTALLED. CUT JAMB FLASHING TO EDGE OF WINDOW OPENING AS 51-1O11N. EXTEND 1-1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HA5 BEEN INSTALLED. (5) INSTALL SI -IT. METAL HEAD FLASHING UNDER (E) BLDG PAPER TRIMMED EDGE - INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOU,N FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW 1/8" LEARANCE BETWEEN FLASHING AND BOT. EDGE OF (E) SIDING. OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. HEAD FLASHING INSTALLATION SCALE: NTS (E) WALL UNDERLAYMENT MEMBRANE FLASHING AT HEAD CUT HEAD FLASHING TO EDGE OF WINDOW OPENING AS SHOWN. EXTEND I -1/T' BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT 51HO1LN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. 0- 1— 0 0 0 WINDOW FLASHING INSTALLATION SCALE: NTS WOOD TRIM INSTALLATION SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE 1/4"-3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: I: MEMBRANE FLASHING 15 SPECIFIED IN 01 62 00 AS "SELF ADNEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5 AND 6" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "1 AND 8" REFER TO SHEET METAL HEAD FLASHING. 5: DETAIL S REFERS TO WOOD TRIM AND CAULK JOINTS. R VIEWED FOR CODE COMPLIANCE APPROVED MAY 022013 City of Tukwila BUILDING DIVISION t)13***b. i RECEIVED CITY OF TUKWILA APR 2 6 2013 PERMIT CENTER ■ S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 REGISTERED A ,. HITECT OCTOBER 19, 2012 0810.03.2325 O I_ J z 0 z w z z 0 0 CD z AIP NUMBER MPROVEMENTS >- 0 Cw w It w 0 z LI_ U It 3-53-0058-045 SEATTLE WASHINGTON DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW FLASHING DETAILS A2.4 0810.03.2325 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN M TG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS SEATTLE RESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR XX OR XX DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X/Y X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION ?V/ A EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL ABBR SG -X XXX (� DNI 1L DN O-4 0 4r- $ Q OR Q EQUIP ID#� x ISI UP VD RA/EA RG SA SA RA/EA SD EA MOD NG NG D 0 • DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE - APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL/ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION WC -1 DESCRIPTION VOLTS PH <.08"WG 9"0 1,2 23 26 23 26 N/A 23 26 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE REMARKS WC -1 EXTERIOR 180 337 <.08"WG 9"0 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL • SRC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2325 3360 4 180 CFM 180 CFM 1 1. VENTILATION PROVIDED PER THE SEATTLE RESIDENTIAL CODE, SECTION M1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE NOTES ON ROOF OR ON EXTERIOR OF BUILDING R-8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING R-8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R-8 1,3 IN CEMENT SLAB OR IN GROUND R-5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT/SWITCH HOURS OF OPERATION SET FURNACE THERMOSTAT TO OPERATE 1 OF EVERY 2 HOURS. b%3 136 MECHANICAL VENTILATION CALCULATION PER SRC M1508.3 QF = QR / (&EGR X F) QR = (FROM TABLE 1508.2) 90 &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 F = FRACTION OF OPERATION 1/2 QF = 90 / (1 X 1/2) = 180 CFM OF EVERY 3 HOURS) = 1 p ��q 170 44/ (%) RECEIVED CITY OF TUKWILA APR 2 6 2013 PERMIT CENTER EXPIRES: 9/08/2014 S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 624-2777 • FAX (206) 624-2973 THE GREENBUSCH GROUP, INC ••••••••10) ACOUSIICAI. DIO VDEO & YECNANCAL DIGINEERING 1900 GEST'tiqtN STREET SUIE 201 SEATIIE, WA 98119 (206) 378-0569 (208) 378-0641 FAX 081003.2325 0 0 Z 0 z L!J E• - Z Z 0 U Z MPROVEMENTS >- 0 LU LU 0 Z LL 0 J z W 0 LU AIP NUMBER 3-53-0058-45 SEATTLE WASHINGTON DATE 09/19/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M 1 .0 081003.2325 STORAGE P /f KITCHEN JN BATH (1iL, DINING ROOM (E)SG 1 (E)SG BEDROOM 1 (E)SG (E)SG 1� MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1'-0" SEE OFFICE STUDY BATH STORAGE SOFFIT, REFER TO ARCHITECTURAL, TYP STUDY 2 LAUNDRY NORTH (E)SG LIVING ROOM (E)SG (E)SG BATH NO MECHANICAL WORK THIS LEVEL D N 0 SITTING ROOM UPPER FLOOR MECHANICAL PLAN SCALE: 1/4" = 1'-0" DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SRC M1508.6.6. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE SEATTLE RESIDENTIAL CODE, CHAPTER M1508.5.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. 4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: (E)SG KITCHEN FAMILY ROOM C3) BASEMENT MECHANICAL PLAN SCALE: 1/4" = 1'-0" NORTH A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. CEILING OUTSIDE AIR DUCT, SIZE AND ROUTE PER PLAN J 0_ Cl_ V) w z 0_ w l FURNACE VOLUME DAMPER FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING MOD, INTERLOCK TO FURNACE POC FLOOR FURNACE ELEVATION SCALE: NONE NORTH FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER SRC M1508.5.2. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER SRC M1508.5.1. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE/RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. HARD DUCT PER PLAN SOFFI T NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS. WALL CAP DETAIL SCALE: NONE (E)SIDING SHEET METAL FLASHING 2X2 BLOCKING WALL CAP RECEIVED CITY OF TUKWILA APR 2 6 2013 PERMIT CENTER 2X2 BLOCKING 2X2 BLOCKINGficiti 1414 S.M. STEMPER ARCHITECTS 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824-2777 • FAX (208) 824-2973 EXPIRES: 9/08/2014 THE GREENBUSCH GROUP, INC •••••••••))) t Auo10 sl :IES 201 3E01Eo c 9 (208) 378-0589 (208) 378-0841 FAX 0810.03.2325 0 0_ J z 0 z w z > 0 V z MPROVEMENTS >- 0 w 2 w c w 0 z 1- w w AIP NUMBER 3-53-0058-45 SEATTLE WASHINGTON DATE 09/19/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL PLANS AND DETAILS M2.0 0810.03.2325 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 03 PROVIDE 'TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH. STORAGE ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION G LIGHTING OR POWER PANEL EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. ® BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. I I I I 1 4 DAMPER CONNECTION D NON-FUSED DISCONNECT SWITCH o MAST, WEATHERHEAD I J TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN ®D SMOKE DETECTOR .1�_�- I ELECTRICAL METER i TIMER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. pT THERMOSTAT — - — E CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT ® UNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR OFFICE STUDY STORAGE LAUNDRY STUDY 2 KITCI-4EN LOWER FLOOR PLAN 1/4" = 1' F K!TCI-4EN k x ID IN ROOM TO FtleklACE DAMPER BEDROOM 1 FAMILY ROOM Q13 -13e) El MAIN FLOOR PLAN 1/4" = 1' NORTH IXI 1_IYINC ROOM D<l x RECEIVED CITY OF TUKWILA APR 2 6 2013 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 IM !NaINE!Ra. INC NaJMirealar anal TM.IR&aawa 1111,1KM— 4...0 PAX all arNIS 0810.03.2325 MPROVEMENTS 0 cw w w (J) 0 z LL ce ceU z w 0 w AIP NUMBER 5-53-0058-045 z O z w LLJ DATE SEPT 17, 2012 ISSUED 95% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN BCR FLOOR PLANS NOTES E1.0 0810.03.2325