HomeMy WebLinkAboutPermit D13-130 - WOLDAI & GHEBREAB RESIDENCE - REMODELWOLDAI & GHEBREAB
RESIDENCE
4735 S 107 ST
D13-130
City Si/Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
DEVELOPMENT PERMIT
Parcel No.:: 5476800122
Address: 4735 S 107 ST TUKW
Suite No:
Project Name: WOLDAI & GHEBREAB RESIDENCE
Permit Number: D13-130
Issue Date: 05/08/2013
Permit Expires On: 11/04/2013
Owner:
Name: WOLDAI SOLOMON G+SENAIT GHEBREAB
Address: 4735 S 107TH ST , TUKWILA WA 98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: S K M CONSTRUCTION INC
Address: 14415 SE 143 PL , RENTON, WA 98059
Contractor License No: SKMCOI*052L3
Lender:
Name: SELF FUNDED - KING COUNTY AIRPORT
Address:
Phone: 206-296-7437
Phone: 425 235-5569
Expiration Date: 12/30/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSXCAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $44,378.00 Fees Collected: $1,460.87
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
**continued on next page**
doc: IBC -7/10
D13-130 Printed: 05-08-2013
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Permit Center Authorized Signature:
I hereby certify that I have read an
governing this work will be complie
N
N
N
Number: 0
Size (Inches): 0
Start Time: End Time:
Volumes: Cut 0 c.y. Fill 0 c.y.
Start Time: End Time:
Private:
Profit: N
Private:
Date:
Public:
Non -Profit: N
Public:
ned this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not pre
construction or the performance of work.
to this permi
Signature:
Print Name:
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this development permit and agree to the conditions attached
.t ' U r% -
Date: 5N/(
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431-3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D13-130 Printed: 05-08-2013
this requirement.
• •
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D13-130 Printed: 05-08-2013
•
CITY OF TUKWILA
Community Development Department
Public Works Deparhnent
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.c.i.tukwila.wa.us
Building Permit No. R---- l 3 0
Mechanical Permit No. M. (3— a .7 9
Plumbing/Gas Permit No.
Public Works Permit No.
•
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.: 5476800122
Site Address: 4735 S. 107th St.
Tenant Name:
Suite Number: Floor:
Property Owners Name: Solomon Woldai and Senait Ghebreab
Mailing Address: 4735 S. 107th St.
New Tenant: 0 Yes ® ..No
Tukwila WA
98178
City State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296-7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker@kingcounty.gov
City State
Fax Number: (206) 269-7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Cointractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
FRCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle WA
98106
Contact Person: Jesse Holgate or Timothy Fenlason
E -Mail Address: jesse@smstemper.com/tfenlason@jonespayne.ccd
City State
Day Telephone: (206) 624-2777
Fax Number: (206) 624-2973
Zip
NEGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
H: A,plications\Forms-Applications On Line\2009 Applications\I-2009 - Permit Application.doc
Revised: 1-2009
bh
City State Zip
Day Telephone:
Fax Number:
Page 1 of 6
• •
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price): $12°F1/9"11. 7 ti7 Existing Building Valuation: $
Scope of Work (please provide detailed information):
This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? 0 Yes
®.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? 0 Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers 0 Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Fonns-Applications On Line\2009 Applications\1-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
l St Floor
2"' Floor
1528
3" Floor
450
Floors thru
Basement
1528
Accessory Structure*
Attai•hed Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? 0 Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers 0 Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Fonns-Applications On Line\2009 Applications\1-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 2 of 6
• •
PERMIT APPLICATION NOTES —Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
[ HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER 0
Sigr..ature:
Print Name:
y
J.
enlason, SM Stemper Architects, PLLC
Date: y1Z41/3
Day Telephone: (206) 624-2777
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
City State Zip
Date Application Accepted:
Date Application Expires:
Staff Initials:dee
H:Ap,hcanons\Fonms-Applications On Line\2009 Applications \I-2009 - Permit Apphcanon.doc
Revist d: 1-2009
bh
Page 6 of 6
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.gov
RECEIPT
Parcel No.: 5476800122 Permit Number: D13-130
Address: 4735 S 107 ST TUKW Status: APPROVED
Suite No: Applied Date: 04/26/2013
Applicant: WOLDAI & GHEBREAB RESIDENCE Issue Date:
Receipt No.: R13-01546
Payment Amount: $1,460.87
Initials: WER Payment Date: 05/08/2013 09:37 AM
User ID: 1655 Balance: $0.00
Payee: PAM KUEHL (PHONE)
TRANSACTION LIST:
Type Method Descriptio Amount
Fayment Credit Crd VISA
Authorization No. 051970
ACCOUNT ITEM LIST:
Description
1,460.87
Account Code Current Pmts
EUILDING - RES
FLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100
000.345.830
640.237.114
Total: $1,460.87
882.65
573.72
4.50
o.:......1. AG AO 9A1.1
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Prop jeer: L n *; (2 D6,Re_Ac L
Type Inspection:
Jy ` ..
f— 1•
Ad s! J C i V ! ri
y-
Dat led r l �2 �
Special Instructions:
Date Wanted: "'aim?
S— t00r p.m.
Requester:
Phone No.
No. 1S-' 2-'2- >;%
Approved per applicable codes.
Corrections required prior to approval. 3
COMMENTS:
f)!,fV i A; Diap
n� svIA .'3/
l k1
Inspector:
Dat
f
U •
n REINSPECTION FEE REQUIRED. Pr or to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. -
PEW' CO
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: D13-130 DATE: 04-26-13
PROJECT NAME: WOLDAI _& GHEBREAB RESIDENCE
SITE ADDRESS: 4735 S 107 ST
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision '# After Permit Issued
DEPARTMENTS*�&vt`
Bilding ivision
Fire Prevention
Public Works ❑ Structural
n
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete n
DUE DATE: 04-30-13
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Please Route1)4 Structural Review Required No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
Notation:
DUE DATE: 05-28-13
Not Approved (attach comments) n
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Documents/routing slip.doc
2-28-02
Contractors or Tradespeople Per Friendly Page
1
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name S K M CONSTRUCTION INC UBI No. 601577401
Phone 4252355569 Status Active
Address 14415 Se 143Rd Pl License No. SKMCOI.052L3
Suite/Apt. License Type Construction Contractor
City Renton
State WA
Zip 98059
County King
Business Type Corporation
Parent Company
Effective Date 6/23/1995
Expiration Date 12/30/2013
Suspend Date
Specialty 1 General
Specialty 2 Unused
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
SKMC0"093L6
S K M
CONSTRUCTION
Construction
Contractor
General
Unused
6/26/1991
6/17/1995
Archived
SKMINI.976QL
S K M INDUSTRIES
INC
Construction
Contractor
General
Unused
11/13/2003
12/6/2009
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
MORRISON, SHEILA K
President
06/23/1995
Bond Amount
MARKET SANDERS
Agent
06/23/1995
06/25/2001
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
5
FIRST NATL INS CO OF
AMERICA
6695979
06/17/2010
Until Cancelled
$12,000.00
04/26/2010
4
DEVELOPERS SURETY
Et INDEM CO
188889C
12/30/2001
Until Cancelled
08/01/2010
$12,000.0012/05/2001
08/18/2011
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
16
James River Ins
000495931
08/21/2012
08/21/2013
$1,000,000.00
08/20/2012
15
James River Ins
00049593
08/21/2011
08/21/2012
$1,000,000.00
08/18/2011
14
COLONY INS CO
EPK300402
08/21/2010
08/21/2011
$1,000,000.00
08/20/2010
13
CENTURY
SURETY CO
CCP616634
08/21/2009
08/21/2010
$1,000,000.0001/20/2010
12
AMERICAN
STATES INS CO
01CH6810051
01/25/2009
01/25/2010
$1,000,000.0001/23/2009
11
AMERICAN
STATES INS CO
01CH6810051
12/30/2008
01/25/2009
$1,000,000.00
12/23/2008
10
AMERICAN
STATES INS CO
01CH6810051
12/30/2007
12/30/2008
$1,000,000.00
12/07/2007
9
AMERICAN
STATES INS CO
01CD87273820
12/30/2006
12/30/2007
$1,000,000.00
12/19/2006
littrie•//fnrtracc uua anvil ni/hhin/Print acme.
05/OR/2013
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00784C12 BID PACKAGE M-37
3-53-0058-045
SEPARATE PERMIT
REQUIRED FOR
14 ft:hank:el
Bectrical
Plumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
SCOPE OF WORK
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE
t0:1)DES ALL iNFoi�!'14TiON iN THE DRAWINGS AND
SPEGPIGATIONICAL 1511NCLUDiNCs BUT NOTTILATION. THE LIMITED CONTRACT INCLUDES
APPLICABLE
YES NO
1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL -FRAMED ACOUSTICAL WINDOWS.
X
2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS.
X
3. INFILL OF EXISTING OPENINGS.
X
4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS.
X
5. INSTALLATION OF STORM DOORS.
X
6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS.
X
1. INSTALLATION OF SECONDARY SKYLIGHTS.
X
8. INSTALLATION OF PET DOORS.
X
9. INSTALLATION OF FIREPLACE FRESH AIR VENT.
X
10. INSTALLATION OF CHIMNEY CAP.
X
II. REGULATED MATERIALS ABATEMENT.
X
12. ATTIC VENT BAFFLES.
X
13. INSTALLATION OF ATTIC INSULATION.
X
14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AiR UNIT AND
ASSOCIATED DUCTING.
X
15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND
ASSOCIATED DUCTING.
X
16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION.
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCHITECTURAL MODIFICATIONS.
X
15. INSTALLATION OF SMOKE DETECTORS.
X
19. NEW ELECTRICAL PANEL / SERVICE.
X
20. KNOB AND TUBE WIRING.
X
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan stih-n;tfal
andmay include additional plan reviewfcLs.
FILE COPY
ft No, 113 1210
Plan review approval is
Approval of construction
the violation of any
., .. , Copy and
If
to .; one.
not authorize
or ordnance. Receipt
is ed
City lb
WILDING DIVISION
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of WA
TuK 4q.
APPLICABLE CODES:
2009 International Residential Code,
International Fire Code,
International Mechanical Code
5416800122
ZONING: 5F1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
V B NON SPRINKLERED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 0 2 2013
City of Tu wila
BUILDIN VISION
LEGAL DESCRIPTION:
THE NORTH 125 FEET OF LOT 14 AS MEASURED ALONG THE EAST LiNE OF MERRiCK'S ACRE TRACTS DIVISION NO. 2
ADDITION TO THE CITY OF SEATTLE, AS PER PLAT RECORDED IN VOLUME 12 OF PLATS, PAGE 41. RECORDED OF KING
COUNTY - EXCEPT THAT PORTION CONVEYED TO KING COUNTY FOR ROAD PURPOSES BY DEED RECORDED UNDER
KING COUNTY RECORDING NO. 2449506, SITUATED IN THE CiTY OF 11JKWiLA, COUNTY OF KiNG, STATE OF WASHINGTON.
DRAWING INDEX
T0.0 TITLE SHEET, PROJECT INFO.
A1.0 FLOOR PLANS 4 NOTES
A1.1 FLOOR PLANS 4 NOTES
42.0 WINDOW TYPES, SCHEDULE 4 DETAILS
42.1 WINDOW TYPES, SCHEDULE 4 DETAILS
422 DOOR TYPES, SCHEDULE 4 DETAILS
42.3 MISCELLANEOUS DETAILS
(f` 42.4 WINDOW FLASHING DETAILS CE1
.0 LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DM INDEX
vtd6\ 2.0 MECHANICAL PLANS AND DETAILS
.O ELECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Fh: 206. 263. 9233
Fax: 206.296.0190
Contact: Sharyn Parker
E-mail: SharynParkerekingcountyrgov
ARCHITECT:
S.M. Stemper Architects PL.L.C.
4000 Delridge Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody
LeungE-mail: Jerryesmstemper.com
melodyesmstemper.com
ACOUSTICAL ENGINEER:
SSA Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206. 831. 0819
Fax: 206.839.0024:. s
Contact: Mohamed Alt:,4llaoua
E-mail: mohamedessaacoustics.com
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St., Suite 201
Seattle, WA 98119
Ph: 206. 318. 0569
Fax: 206.318.0641
Contact: Dylan Turner
E-mail: DylanTegreenbuschcom
ELECTRICAL ENGINEER
Tres West Engineers
2102 5. 42nd Street, Suite 301
Tacoma, WA 98409
Fh: 253. 412. 3300
Fax: 253.412.3463
Contact: Brent Rollins
E-mail: bcretreswest.com
REGULATED MATERIALS:
P55 Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph: 206. 232. 9639
Fax: 206.162.4180
Contact: Tim Ogden
E-mail: tim ogdenepbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. 0200
Boston, MA 02114
Contact: Tim Fenlason,
Cynthia Maeda
E-mail: tfenlasoneJonespayne.com
CMaeda eJonespayne.com
STRUCTURAL ENGINEER:
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 98121
Ph: 206.. 622. 4580
Fax: 206.622.0422
Contact: Ron Martinson
E-mail: ronmepsm-engineers.com
VICINITY MAP (NTS)
RECEIVE
CITY OF TUKWILA
APR 2 6 20113
PERMIT CEN -ER
13.13d
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
REGISTERED
A-CHITECT
OCTOBER 19, 2012
0810.03.2325
F-
O
rzd
Z
O
z
w
z
z
0
U
U
Z
MPROVEMENTS
>-
0
w
w
w
O
z
LL
0
Ct
-JF.-
z
w
0
w
AIP NUMBER
3-53-0058-045
z
0
0
z_
w
LL!
cn
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
PROJECT
INFORMATION,
DRAWING
INDEX,
DIRECTORY
T0.0
0810.03.2325
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 0 2 2013
City of Tukwila
BUILDING DIVISION I
SPECIAL NOTES:
I. LEAD PAINT 15 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 11 01
AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
2. REFERENCE 4/423 FOR SMOKE/ CARBON MONOXIDE DETECTOR
INSTALLATION DETAIL.
STORAGE
OFFICE
STUDY
BATH
STORAGE
FUR
STUDY
2
LAUNDRY
IE
(E) /7.
INTERIOR
SOFFIT
FAMILY
ROOM
/(E)
FIREPLACE
INSERT
PRIOR TO COMMENCING WITH DEMOLITION
A "pre -demo inspection" is required.
Contractors shall provide documentation that
an "asbestos survey" has been completed. If
needed, abatement procedures per "Puget
Sound Clean Air Agency" shall be completed
and documentation of compliance shall be
provided at time of final inspection.
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. HOMEOUNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 FM TO 8:00 AM EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 15 ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 FM.
6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED.
1. ADD SOLID WOOD BLOCKING AT WINDOWS.
8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PANELS, DUCTS E SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
la INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS 51-IEET.
19. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR TI -IE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 PM.
LOWER FLOOR PLAN
1/4" = 1' - 0"
PLAN KEYNOTES
Oj DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE.
02 DEMOLISH EXISTING DOOR(S), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND
STORM DOOR REF. DOOR SCHEDULE.
0
O INSTALL SECONDARY SKYLIGHT UNDER (E) SKYLIGHT. MAXIMUM AIR SPACE BETWEEN SKYLIGHTS SHALL BE 4". VERIFY EXISTING
CONDITIONS AND NOTIFY TECHNICAL REPRESENTATIVE IF EXISTING CONSTRUCTION DOES NOT ALLOW FOR TI -115. REF. 2/A23 FOR DETAIL.
OINSTALL NEW SECONDARY SLIDING DOOR(S). REF. DOOR SCHEDULE.
O DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A23 FOR DETAIL. COORDINATE WITH
MECHANICAL DOCUMENTS.
OINSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS.
O DEMOLISH EXISTING DOOR(5), FRAME, CASING, AND THRESHOLD. INSTALL NEW PRIMARY AND SECONDARY SLIDING DOOR(5). REF: DOOR
SCHEDULE.
REMOVE (E) WINDOW AND REPLACE WITH ACOUSTICAL WINDOW ASSEMBLY. EXISTING WINDOWS NOTED ARE LOCATED IN SLEEPING AREAS
(1)1AND DO NOT COMPLY WITH EGRESS REQUIREMENTS. CUT DOWN EXISTING WALL CONSTRUCTION TO COMPLY WITH EGRESS REQUIREMENTS.
REPAIR AND FINISH WALL TO MATCH ADJACENT EXISTING CONSTRUCTION. FOR BIDDING PURPOSES, ASSUME WINDOW SIZING FOR EGRESS.
REF: WINDOW SCHEDULE ON SHEET 42.0.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
RECEIVED
CITY OF TUKWILA
APR 2 6 2013
PERMIT CENTER
LEGEND
A
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR/ STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
A. EAST ELEVATION
B. SOUTH ELEVATION
C. WEST ELEVATION
D. NORTH ELEVATION
D 13� 13o
1111111111111
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE
FEATHER TEXTURED CEILING OVER AT A
MN. OF 24" FROM EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND UJI-IDLE HOUSE VENT INSTALLATION.
REF. MECH. 4 ELECT.
REF. GENERAL NOTE 11
r----- ATTIC INSULATION
ATTIC INSULATION DAM
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
SC INSTALL BATTERY OPERATED SMOKE /
CARBON MONOXIDE DETECTORS
GAS METER
SOFFIT FOR MECHANICAL DUCTING
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
SCOTT
STATE O=
TEMPE
liASHINGTON
OCTOBER 19, 2012
0810.03.2325
O
0
J
z
0
>
z
w
z
z
O
U
0
z
MPROVEMENTS
>-
0
w
w
w
0
z
u_
0
J
z
w
0
C1)
w
r
AIP NUMBER
3-53-0058-045
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
NOTES
A1 .0
0810.03.2325
DECK
❑2
KITCHEN
SPECIAL NOTES:
1. LEAD PAINT 16 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 11 01
AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
2. REFERENCE 4/423 FOR SMOKE/ CARBON MONOXIDE DETECTOR
INSTALLATION DETAIL.
BEDROOM
2
L!
BATT -I
DINING
ROOM
BEDROOM
1
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WDRK DAILY.
3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 16 ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8•.00 AM AND 5:00 PM.
6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
1. ADD SOLID WOOD BLOCKING AT WINDOWS.
8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 50 AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE AIRE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORD. REFER TO ELECTRICAL
FOR TIMER LOCATION
18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AI.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS SHEET.
19. CONTRACTOR 16 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE ..00 AM. 4 AFTER 5:00 PM.
MAIN FLOOR PLAN
1/4"= 1'-0"
DECK
ffEl
LIVING
ROOM
(E)
FIREPLACE
INSERT
A. EAST ELEVATION
REVIEWED VIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 0 2 2013
City of Tukwila
,uILDING DIVISION
B. SOUTH ELEVATION
PLAN KEYNOTES
Oi DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE.
O DEMOLISH EXISTING DOOR(S), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND
2 STORM DOOR REF. DOOR SCHEDULE.
0
O INSTALL SECONDARY SKYLIGHT UNDER (E) SKYLIGHT. MAXIMUM AIR SPACE BETWEEN SKYLIGHTS SHALL BE 4". VERIFY EXISTING
CONDITIONS AND NOTIFY TECHNICAL REPRESENTATIVE IF EXISTING CONSTRUCTION DOES NOT ALLOW FOR 11416. REF. 2/423 FOR DETAIL.
OINSTALL NEW SECONDARY SLIDING DOOR(S). REF. DOOR 501-IEDULE.
O DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A23 FOR DETAIL. COORDINATE WITH
MECHANICAL DOCUMENTS.
OINSTALL NEW THEFVOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS.
O DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW PRIMARY AND SECONDARY SLIDING DOOR(S). REF: DOOR
SCHEDULE.
O REMOVE (E) WINDOW AND REPLACE WITH ACOUSTICAL WINDOW ASSEMBLY. EXISTING WINDOWS NOTED ARE LOCATED IN SLEEPING AREAS
AND DO NOT COMPLY WITH EGRESS REQUIREMENTS. CUT DOWN EXISTING WALL CONSTRUCTION TO COMPLY WITH EGRESS REQUIREMENTS.
REPAIR AND FINISH WALL TO MATCH ADJACENT EXISTING CONSTRUCTION. FOR BIDDING PURPOSES, ASSUME WINDOW SIZING FOR EGRESS.
REF: WINDOW SCHEDULE ON 51-IEET 42.0.
ACCESS TO SITE AND PARKING
I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO I-IOMEOU.NER DRIVEWAY.
BATT -I
14
l
SITTING
ROOM
C2/‘ UPPER FLOOR PLAN
1 /4 1' - 0"
C. WEST ELEVATION
LEGEND
r I
❑X
Nil
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR/ STOR'1 DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
RECEIVED
CITY OF TUKWILA
APR 2 6 2013
PERMIT CENTER
D. NORTH ELEVATION
b 13
1111111111111
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE
FEATHER TEXTURED CEILING OVER AT A
MIN. OF 24" FROM EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
REF. MECH. d ELECT.
REF. GENERAL NOTE 11
r--- ATTIC INSULATION
ATTIC INSULATION DAM
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
SC INSTALL BATTERY OPERATED SMOKE /
CARBON MONOXIDE DETECTORS
'GAS
GAS METER
SOFFIT FOR MECHANICAL DUCTING
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
REGISTERED
A.CHITECT
SCOTT TEMPE'
STATE 0= VIHSHINGTON
OCTOBER 19, 2012
0810.03.2325
O
z
O
z
w
z
›-
1—
C.)
—
U
0
z
AIP NUMBER
MPROVEMENTS
>-
0
w
2
w
r
w
(/)
0
z
U
—J
1—
z
w
0
U)
Lu
3-53-0058-045
z
0
z
w
Q
U)
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
NOTES
A1 . 1
0810.03.2325
WINDOW TYPES
I.
HORIZONTAL
XX SLIDER
i
2.
CASEMENT/ FIXED/
CASEMENT
i
3.
FIXED
4.
SECONDARY
SKYLIGHT
(FIXED OR OPERABLE)
5.
CASEMENT
6.
SLIDER OVER FIXED
1. 8.
CASEMENT/ FIXED SLIDER/ FIXED/ SLIDER
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
-.1---
1. 8.
CASEMENT/ FIXED SLIDER/ FIXED/ SLIDER
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
DETAIL
SET
A
BEDROOM 1
8
6' -II" x 1' -II"
STAIN/STAIN
CUT SILL DOWN 11" FOR EGRESS. (E) SILL HT IS 51" AFF
1/42.0
B
BEDROOM 2
I
3'-I0" x 2'-10"
STAIN/STAIN
SAFETY GLAZING REQUIRED
CUT SILL DOWN 8" FOR EGRESS. (E) SILL NT 15 48" AFF
I/42.1
C
BEDROOM 2
1
3'-10" x 2'-10"
STAIN/STAIN
SAFETY GLAZING REQUIRED
CUT SILL DOWN 8" FOR EGRESS. (E) SILL 1 -IT IS 48" AFF
I/42.1
D
BEDROOM 2
4
I'-10" x 4'-0"
STAIN/STAIN
SKYLIGHT, SAFETY GLAZING REQUIRED
2/423
E
KITCHEN
2
5'-10" x 3'-10"
STAIN/STAIN
SAFETY GLAZING REQUIRED
1/42.0
F
KITCHEN
2
5'-10" x 3'-10"
STAIN/STAIN
I/42.0
G
KITCHEN
5
2'-9" x 2' -II"
STAIN/STAIN
2/A2.I
H
KITCHEN
4
I'-10" x 4'-0"
STAIN/STAIN
SKYLIGHT, SAFETY GLAZING REQUIRED
2/423
1
)INING ROOM
6
4'-10" x 4'-4"
STAIN/STAIN
1/42.0
J
DINING ROOM
2
4' -Il" x 2'-10"
STAIN/STAIN
SAFETY GLAZING REQUIRED
1/42.0
K
LIVING ROOM
2
5' -II" x 3'-I0"
STAIN/STAIN
SAFETY GLAZING REQUIRED
1/42.0
L
LIVING ROOM
2
5'-11" x 3'-10"
STAIN/STAIN
SAFETY GLAZING REQUIRED
1/42.0
M
LIVING ROOM
2
1'-11" x 3'-10"
STAIN/STAIN
2/42.0
N
SITTING ROOM
5
2'-2" x 2' -II"
STAIN/STAIN
1/42.0
O
SITTING ROOM
1
4'-11" x 3'-4"
STAIN/STAIN
1/42.0
P
OFFICE
I
2'-10" x I'-11"
STAIN/STAIN
1/42.0
Q
STUDY
I
5'-I0" x 1'-10"
STAIN/STAIN
1/42.0
R
STUDY 2
I
5'-10" x P -I0"
STAIN/STAIN
1/42.0
5
FAMILY ROOM
I
5'-I0" x 3'-I0"
STAIN/STAIN
SAFETY GLAZING REQUIRED
3/42.0
T
FAMILY ROOM
I
5'-I0" x 3'-10"
STAIN/STAIN
SAFETY GLAZING REQUIRED
3/A2.0
U
FAMILY ROOM
1
3'-10" x 2'-11"
STAIN/STAIN
SAFETY GLAZING REQUIRED
3/42.0
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
TO MATCH (E) SIDING.
PRE -PRIMED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
REMOVE (E) WD. SIDING FOR
(E) GWB
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
/-TOUCH UP PAINT, AS REQ'D
CONTINUOUS
SEALANT, TYP.
INSTALLATION OF NEW WINDOW TRIMS
AND REATTACI-IMENT OF (E) SIDING TO
WINDOW OPENING LAMING. LIFT (E)
WALL UNDERLAYMENT AND INSTALL
WINDOW / NAILING FLANGE OVER SELF
ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER
NAILING FLANGE AND LAP UNDER (E)
WALL UNDERLAYMENT. CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PAINT MODIFIED SIDING
10 MATCH (E) SIDING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
WINDOW HEAD
SOLID WOOD TRIM
WD. JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
(E) GWB
TOUCH UP PAINT, AS REQ'D
WINDOW JAMB
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WD SIDING
WINDOW SILL
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD 4
SEALANT
3/4" WOOD SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
TOUCH UP PAINT, AS REQ'D
SELF -ADHERING
MEMBRANE
(E) GWB
WOOD SIDING - WINDOW DETAIL SET
3"=1'-0"
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT. OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING A5 REQ'). MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
TO MATCH (E) SIDING.
PRE -PRIMED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
8E SELECTED IN 114E FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
REMOVE (E) WD. SIDING FOR
71 III II
INSTALLATION OF NEW WINDOW TRIMS
AND REATTACHMENT OF (E) SIDING TO
WINDOW OPENING FRAMING. LIFT (E)
WALL UNDERLAYMENT AND INSTALL
WINDOW / NAILING FLANGE OVER SELF
ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER
NAILING FLANGE AND LAP UNDER (E)
WALL UNDERLAYMENT. CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PAINT MODIFIED SIDING
TO MATCH (E) SIDING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW
ASSEMBLY
IREVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 0 2 2013
City of Tukwila
BUILDING DIVISION
(E) GWB
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
/----TOUCH UP PAINT, AS REQ'D
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WINDOW HEAD
W). JAMB LINING
SEALANT AND BACKER ROD
SHIM AS NECESSARY
SELF -ADHERING MEMBRANE
LAP OVER (E) WALL
UNDERLAYMENT AND (E) SILL
(E) BRICK VENEER
WINDOW JAMB
1
II
J
II
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
(E) GWB
TOUCH UP PAINT, AS REQ'D
/4"
WINDOW SILL
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
SEALANT 4 BACKER ROD
3/4" WOOD SILL
SOLID WOOD TRIM
CONTINUOUS SEALANT, TYP.
TOUCH UP PAINT, AS REQ'D
WOOD SIDING - WINDOW DETAIL SET
3"=1'-0"
(E) GWS
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET.
SLOPE
1" min.
min.
L
HEMMED EDGE 1 END CLOSURE
HEAD FLASHING DETAIL TYP.
3" = 1' - 0"
EXISTING MASONRY VENEER
SEALANT AND BACKER ROD
(E) EXTERIOR SHEATHING
SELF ADHERING MEMBRANE
TOUCH UP PAINT, AS REQ'D
CONTINUOUS SEALANT, TYP.
SOLID WOOD TRIM
WOOD LINING
SEALANT AND BACKER ROD
ACOUSTICAL WINDOW ASSEMBLY
(E) EXTERIOR SHEATHING
(E) MASONRY VENEER
SELF ADHERING MEMBRANE
WINDOW HEAD
SEALANT AND BACKER ROD -�
ACOUSTICAL WINDOW
ASSEMBLY
SEALANT AND BACKER ROD
514I11 AS NECESSARY
SHIM AS NECESSARY FILL
GAP W/ BATT INSULATION
(E) GLOB
TOUCH UP PAINT, A5 REQ'D
CONTINUOUS SEALANT, TYP.
SOLID WOOD TRIM
WOOD LINING
SEALANT 4 BACKER ROD
ACOUSTICAL
WINDOW ASSEMBLY
RECEIVED
WINDOW JAMB CITY OF TUKWILA
APR 2 6 2013
PERMIT CENTER
/4"
SELF -ADHERING MEMBRANE
LAP OVER (E) WALL
UNDERLAYMENT AND (E) SILL
(E) BRICK VENEER
SEALANT 4 BACKER ROD
3/4" WOOD SILL
SOLID WOOD TRIM
- CONTINUOUS SEALANT, TYP.
TOUCH UP PAINT, A5 REQ'D
(E) GWS
bvi,130
WINDOW SILL
BRICK VENEER SIDING - WINDOW DETAIL SET
3" = 1' - 0"
u
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973.
4220
REGISTERED
A cHITECT
COTT
STATE OF
OTEMPE
SHINCTOK'
OCTOBER 19, 2012
0810.03.2325
O
0
J
z
0
>
z
w
z
z
0
V
z
MPROVEMENTS
>-
0
w
w
w
0
z
IL
0
AIP NUMBER
3-53-0058-045
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.2325
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 0 2 2013
City of Tukwila
BUILDING DIVISION
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF-ADI-IERING
MEMBRANE AGAINST SHEATHING:. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF -ADHERING: MEMBRANE. TYP AT 1-IEAD
AND JAMB
REMOVE (E) SIDING AS REQ'D FOR
INSTALLATION OF WINDOW ASSEMBLY 4
FLASHING. REPLACE W/ NEW SIDING 4
PAINT TO MATCH (E) SIDING
PRE -PRIMED, GALV SI-EET METAL
FLASHING W END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
(E) GWB
/ TOUCH UP PAINT, A5 REQ'D
�/ CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD. JAMB LININGS. FINISH TO
MATCH (E)
SEALANT 4 BACKER ROD
CAREFULLY CUT BACK (E) SIDING TO
ALLOW FOR REATTACHMENT TO R.O.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST 51-1EATHING. INSTALL SECOND
LAYER OF SELF ADHERMG MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR 5HEATHING
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E)
TRIM. COLOR TO BE FIELD
DETERMINED
REPLACEMENT
WINDOW ASSEMBLY
PER SCHEDULE AND
SPECIFICATION
BACKER ROD 4 SEALANT
REPLACEMENT
WINDOW ASSEMBLY
PER SCHEDULE AND
SPECIFICATION
0
WINDOW HEAD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
REPLACEMENT WINDOW
ASSEMBLY FER SCHEDULE
AND SPECIFICATION
WINDOW JAMB
(E) GWB
TOUCH UP PAINT, A5 REQ'D
CAREFULLY REMOVE (E) SIDING FOR
INSTALLATION OF WINDOW ASSEMBLY
AND TRIM. REPLACE W/ NEW SIDING AS
REQ'D TO MAINTAIN COURSING 4 PAINT
TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
IS
WINDOW SILL
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
W. JAMB LINING. FINISH TO
MATCH (E)
SEALANT 4 BACKER ROD
BACKER ROD 4 SEALANT
3/4" WD. SILL - STAIN TO
MATCH (E)
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
TOUCH UP PAINT, AS REQ'D
SELF -ADHERING MEMBRANE
(E) GWS
BRICK VENEER SIDING - WINDOW DETAIL SET
3"= 1'-0"
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
TO MATCH (E) SIDING.
PRE -PRIMED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
REMOVE (E) WD. SIDING FOR
(E) GUMS
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
TOUCH UP PAINT, AS REQ'D
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD. JAMB LINING
INSTALLATION OF NEW WINDOW TRIMS
AND REATTACHMENT OF (E) SIDING TO
WINDOW OPENING FRAMING. LIFT (E)
WALL UNDERLAYMENT AND INSTALL
WINDOW / NAILING FLANGE OVER SELF
ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER
NAILING FLANGE AND LAP UNDER (E)
WALL UNDERLAYMENT. CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PAINT MODIFIED SIDING
TO MATCH (E) SIDING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR 514EATHING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW. NAILING FIN
WINDOW HEAD
SEALANT
514IM A5 NECESSARY
FILL GAP W/ BATT
INSULATION
(E) CERAMIC TILE
(E) GLIB
WINDOW JAMB
CONTINUOUS
SEALANT, Tl -P.
SOLID WOOD TRIM
WD JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD 4
SEALANT
3/4" WOOD SILL
SOLID WOOD TRIM
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WD SIDING
WINDOW SILL
SELF -ADHERING
MEMBRANE
(E) CERAMIC TILE
(E) GWB
WOOD SIDING - WINDOW DETAIL SET
3"= 1'-0"
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET.
SLOPE
v
E
N
1" min.
min.
HEMMED EDGE J
END CLOSURE
HEAD FLASHING DETAIL TYP.
3"= 1'-0"
Dia-
RECEIVED
CITY OF TUKWILA
APR 2 6 2013
PERMIT CENTER
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206)624-2777 • FAX (206) 824-2973
4220
REGISTERED-
AL0HITECT
COTT dTEMP
STATE OF :ti SHPIGTON"
OCTOBER 19, 2012
0810.032325
O
0
J
z
0
Q
z
w
E'-
z
>-
z
0
0
0
z
MPROVEMENTS
>-
0
w
w
w
0
z
U
tz
AIP NUMBER
3-53-0058-045
SEATTLE WASHINGTON
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.2325
DOOR TYPES
M
81113
,A
FLUSH SCW
W/ WAGON WHEEL
AND 4 PANELS
W/ SAFETY GLAZING
W/ OBSERVATION PORT
c
FLUSH 5CW PRIMARY/ SECONDARY
W/ SIX PANELS SLIDING GLASS DOOR
W/ OBSERVATION PORT W/ SAFETY GLAZING
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GLAZING
E
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GRILLE
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
1
ENTRY
A
3'-0" x 6'-8"
STAIN/ STAIN
HW -I / 609
DK -4
LOCK -I
I/422
2
KITCHEN
C
5' -II" x 6'-8"
3/422
3
LIVING ROOM
C
5'-11" x 6'-8"
2/422
4
STUDY 2
B
2'-8" x 6'-8"
STAIN/ STAIN
1-11U-1 / 609
DK -4
LOCK -I
1/422
5
FAMILY ROOM
A
2'-8" x 6'-8"
STAIN/ STAIN
HW -1 / 609
DK -4
LOCK -I
I/422
6
ENTRY
D
3'-0" x 6'-S"
I/422
1
STUDY 2
E
2'-8" x 6'-8"
1/422
8
FAMILY ROOM
D
2'-S" x 6'-8"
I/A22
9
KITCHEN (PRIMARY)
C
5' -II" x 6'-8"
3/422
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW DOOR ASSEMBLY
AND TRIM. REPLACE OR RE INSTALL
SIDING AS REQ'D. MAINTAIN (E)
COURSING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
PRE -PRIMED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN TI -IE FIELD
CONTINUOUS SEALANT BEI-IIND Z BAR
FRAME
STOW DOOR PER SCHEDULE
2" MIN.
(E) EXTERIOR SHEATHING
SELF -ADHERING
MEMBRANE
TOUCH UP PAINT AS, REQ'D
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
514IM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
REMOVE (E) WD. SIDING FOR INSTALLATION
OF NEW DOOR TRIMS AND REATTACHMENT
OF (E) SIDING TO DOOR OPENING FRAMING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK
NEW VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PAINT MODIFIED SIDING TO
MATCH (E) SIDING
(E) WOOD SIDING
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
DOOR HEAD
(E) EXTERIOR SHEATHING
TOUCH UP PAINT, AS REQ'D
CONTINUOUS
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER-STRIPPING
JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
SILL N HEAD OF SEALANT
2" MIN.
DOOR JAMB
DOOR SILL
SEALANT, TYP.
EXISTING FRAMING
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
(Th WOOD SIDING - DOOR DETAIL SET
3"=1'-0"
(E) WD. SIDING
PRE -PRIMED, GALV 51-IEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
SELF -ADHERING MEMBRANE. TURN DOWN
OVER FRONT EDGE OF TRIM. ENSURE
NO MEMBRANE 15 VISIBLE BELOW
FLASHING EDGE
2X TAPERED CAP
REMOVE (E) SIDING TO FACILITATE
INSTALLATION OF FLASHING AND DOOR
HEAD ASSEMBLY
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING
AROUND PERIMETER OF DOOR FRAME.
PAINT ALL EXPOSED EDGES TO MATCH
(E) TRIM
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
(E) WALL UNDERLAYMENT
DOOR HEAD
BACKER ROD AND SEALANT
SELF-ADHEARING MEMBRANE
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING AROUND
PERIMETER OF DOOR FRAME. PAINT ALL
EXPOSED EDGES TO MATCH (E) TRIM
TRIM- PANT TO MATCH (E) TRIM
SELF -ADHERING MEMBRANE
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTION5
WD. TRIM BEYOND
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF -ADHERING MEMBRANE
REMOVE (E) WO0D SIDING AND
REPLACE AS REQ'D. LIFT (E)
WALL UNDERLAYMENT AND
INSTALL SELF -ADHERING
MEMBRANE PENETRATION
FLASHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF
PENETRATION FLASHING. PAINT
MODIFIED SIDING TO MATCH (E)
SIDING. TYP. AT HEAD AND
JAMBS
•
_•�r"r"iJ _440
SOLID WOOD LINING
(E) PRIMARY SLIDING DOOR
ASSEMBLY.
(E) WD. SIDING
(E) EXTERIOR SHEATHING
LIFT (E) WALL UNDERLAYMENT.
LAP NEW UNDERLAYMENT UNDER
(E) UNDERLAYMENT 2" AND
CONTINUE OVER SLIDING GLASS
DOOR FRAME
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS.
SEALANT
(E) FLOOR/ DECK FRAMING
11
i" MIN. BETWEEN PRIMARY
AND SECONDARY SLIDING
GLASS DOOR FRAMES
DOOR JAMB
SOLID WOOD LINING
(E) PRIMARY SLIDING
GLASS DOOR
(E) SLIDING GLASS
DOOR
(E) FINISH FLOOR
(E) INTERIOR CONC. SLAB.
OR (E) WD. FLOOR FRAMING
DOOR SILL
WOOD SIDING - DOOR DETAIL SET
3"=1'-0"
(E) WD. SIDING
PRE -PRIMED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
EE SELECTED IN THE FIELD
SELF -ADHERING MEMBRANE. TURN DOWN
OVER FRONT EDGE OF TRIM. ENSURE
NO MEMBRANE 15 VISIBLE BELOW
FLASHING EDGE
2X TAPERED CAP
REMOVE (E) SIDING TO FACILITATE
INSTALLATION OF FLASHING AND DOOR
HEAD ASSEMBLY
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING
AROUND PERIMETER OF DOOR FRAME.
PAINT ALL EXPOSED EDGES TO MATCH
(E) TRIM
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
(E) WALL UNDERLAYMENT
TYPICAL DOOR SCHEDULE NOTES
1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN
SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS
AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK.
5. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET.
SLOPE
I" min.
1/4."`min.
HEMMED EDGE
END CLOSURE
CAHEAD FLASHING DETAIL TYP.
3 -1 -0
DOOR HEAD
BACKER ROD AND SEALANT
SELF-ADHEARING MEMBRANE
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING AROUND
PERIMETER OF POOR FRAME. PAINT ALL
EXPOSED EDGES TO MATCH (E) TRIM
TRIM- PAINT TO MATCH (E) TRIM
SELF -ADHERING MEMBRANE
SECONDARY SLIDING STOW DOOR
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
WD. TRIM BEYOND
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS.
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF -ADHERING MEMBRANE
REMOVE (E) WOOD SIDING AND
REPLACE AS REQ'D. LIFT (E)
WALL UNDERLAYMENT AND
INSTALL SELF -ADHERING
MEMBRANE PENETRATION
FLASHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF
PENETRATION FLASHING. PAINT
MODIFIED SIDING TO MATCH (E)
SIDING. TYP. AT HEAD AND
JAMBS
SOLID WOOD TRIM
SOLID WOOD LINING
NEW PRIMARY SLIDING
GLASS DOOR INSTALL PER MFG'R
INSTRUCTIONS
(E) WD. SIDING
(E) EXTERIOR 51-IEATHING
LIFT (E) WALL UNDERLAYMENT.
LAP NEW UNDERLAYMENT UNDER
(E) UNDERLAYMENT 2" AND
CONTINUE OVER SLIDING GLASS
DOOR FRAME
11
i" MIN. BETWEEN PRIMARY
AND SECONDARY SLIDING
GLASS DOOR FRAMES
DOOR JAMB
SEALANT
(E) FLOOR/ DECK FRAMING
SOLID WOOD TRIM
SOLID WOOD LINING
NEW PRIMARY SLIDING
GLASS DOOR INSTALL PER
MFG'R INSTRUCTIONS
NEW PRIMARY SLIDING
GLASS DOOR INSTALL PER
MFG'R INSTRUCTIONS
(E) FINISH FLOOR
(E) INTERIOR CONC. SLAB.
OR (E) WD. FLOOR FRAMING
REVIEWED FOR
ODE COMPLIANCE
APPROVED
MAY 022013
DOOR SILL
WOOD SIDING - DOOR DETAIL SET
3"=1'-0"
City of Tukwila
ILDING DIVISION
RECEIVED
CITY OF TUKWIL A
APR 2 6 2013
PERMIT CENTER
■
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
REGISTERED
A rHITECT
COTT idTEMPE°
STATE OF • 'SHINCTON''
OCTOBER 19, 2012
0810.03.2325
O
0
J
z
0
>
z
w
z
z
0
U
0
z
AIP NUMBER
MPROVEMENTS
>-
0
w
2
w
0
z
U
J
z
w
Lu
3-53-0058-045
z
0
1-
0
z_
w
1-
1 -
DATE
-
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
Jo
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.2
0810.03.2325
EXISTING
CEILING
STRUCTURE
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 0 2 2013
City of Tukwila
BUILDING DIVISION
a INA
x1
1
J
DUCT/ SOFFIT DETAIL
1-1/2" = 1' - 0"
/
DUCTS PER PLAN WITHIN SOFFIT
RE: MECHANICAL
2x2 CONT. NAILER
%" GWB- PAINT TO MATCH (E)
TEXTURE 4 COLOR OF CEILING.
ENCLOSE DUCTS TIGHTLY, OR
TERMINATE EDGE W/ ADJ
ARCHITECTURAL FEATURES PER PLAN.
COORDINATE SOFFIT DIMENSIONS WITH
MECHANICAL
(E) WD FRAME WALL ASSEMBLY
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT NEAR AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF VENT FIXTURE AND
FLASHING. REPLACE OR RE INSTALL
SIDING AS REQ'D. MAINTAIN (E)
COURSING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
PRE -PRIMED, GALV. 51-EET METAL
FLASHING W/ FF. END CAPS UNDER
SELF -ADHERING MEMBRANE. EXTEND
FLASHING 4" UP WALL. PAINT COLOR TO
BE SELECTED IN THE FIELD
PAINT VENTILATION HOOD,
COLOR TO BE SELECTED IN
THE FIELD
EXTERIOR VENTILATION HOOD.
REF. MECH.- PAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
REMOVE / REPLACE (E) SIDING AS
REQUIRED.
(E) WALL UNDERLAYMENT
SELF -ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
2X BLOCKING
2X2 CONTINUOUS PRESSURE
TREATED BLOCKING, 4 SIDES
AIR INTAKE DETAIL AT EXTERIOR
3"= 1'-0"
2X WD LEDGER, TYP.
SEALANT, ALL SIDES
2X WD FRAME W/
2X BLOCKING
EXIST. SKYLIGHT
CONSTRUCTION
MITERED CORNERS
MATCH (E) ADJACENT FINISH
WOOD STOP, TYP.
CASEMENT LATCH
SECONDARY SKYLIGHT DETAIL
1 1/2"= 1'-0"
CEILING
4" MIN
NOTE: REMOVE EXISTING SMOKE
DETECTORS, CUT AND PATCH CEILING AS
REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND
TEXTURE AND PAINT TO FILL ALL HOLES
LEFT FROM EXISTING CONDITION. PAINT
TO MATCH SURROUNDING CONDITIONS.
z
EXIST. CEILING
1/4" TEMPERED GLASS
SIDE WALL
DETECTOR INSTALLATION DETAIL TYP.
3"= 1'-0"
13-13t)
RECEIVED
CITY OF TUKWILA
APR 2 6 2013
PERMIT CENTER
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
REGISTERED -
AL HiTECT
1r#
COU 4TEMP •
STATE Or SHINGTON
OCTOBER 19, 2012
0810.03.2325
F --
O
0
>-
J 0
Q W
z
O w
z
w O
�- z
U
O
U <
(� J
Z Q
Z
w
0
w
MPROVEMENTS
AIP NUMBER
3-53-0058-045
Z
0
CD
z
Lu
Q
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
MISC.
DETAILS
A2.3
0810.03.2325
LIFT (E) WALL
UNDERLAYMENT
AWAY LOOSELY
FROM (E) SHEATHING
AT JAMBS AND HEAD
BUTTERFLY
CORNERS, TYP.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
12"
LAP SILL MEMBRANE
FLASHING 2-I/2"
OVER (E) BLDG.
PAPER AT SILL.
EXTEND 12 BEYOND
RO. AT EA. END OF
SILL.
(E) WALL
(E) SHEATHING
CUT SILL
FLASHING TO
EDGE OF RO. A5
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
I" MIN
UNDERLAYMENT
AT SILL
MEMBRANE FLASHING AT SILL
4
BUTTERFLY CORNER FLASHING
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1-1A5 BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE N SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
51-1OULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) WALL
UNDERLAYMENT
AT SILL.
O '
0
0
0
0
0
0
0
0 0 0
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
REMOVED
SCALE: NTS
EDGE OF (E)
SIDING, SHOWN
D I AGRAMAT ICAL L Y.
(E) SIDING
NOT 5HOWN
FOR CLARITY.
LAY (E) WALL
UNDERLAYMENT
BACK DOWN
OVER FLANGE
FLASHING AT
JAMBS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D
(E) SIDING NOT 51-1OWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1-1A5 BEEN INSTALLED.
r
7
WHERE REQUIRED, TRIM
(E) WALL
UNDERLAYMENT At
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRIM
(FOLLOWING STEPS).
L J
HEAD FLASHING PREPARATION
SCALE: NTS
(E) WALL
UNDERLAYMENT
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SI -1011N FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1-1A5 BEEN INSTALLED.
CUT JAMB FLASHING TO
EDGE OF WINDOW OPENING
AS 51-1O11N. EXTEND 1-1/2"
BEYOND EDGE OF
OPENING AT HEAD, JAMBS,
AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HA5 BEEN INSTALLED.
(5)
INSTALL SI -IT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER
TRIMMED EDGE
- INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOU,N FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED. ALLOW 1/8"
LEARANCE
BETWEEN FLASHING AND
BOT. EDGE OF (E)
SIDING.
OF (E) SIDING,
SHOWN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) WALL
UNDERLAYMENT
MEMBRANE FLASHING AT HEAD
CUT HEAD
FLASHING TO
EDGE OF WINDOW
OPENING AS
SHOWN. EXTEND
I -1/T' BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT 51HO1LN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
0-
1—
0
0 0
WINDOW FLASHING INSTALLATION
SCALE: NTS
WOOD TRIM INSTALLATION
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
SCALE: NTS
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE 1/4"-3/8" GAP
BETWEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
I: MEMBRANE FLASHING 15 SPECIFIED IN 01 62 00 AS
"SELF ADNEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5 AND 6" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "1 AND 8" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAIL S REFERS TO WOOD TRIM AND CAULK
JOINTS.
R VIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 022013
City of Tukwila
BUILDING DIVISION
t)13***b. i
RECEIVED
CITY OF TUKWILA
APR 2 6 2013
PERMIT CENTER
■
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
REGISTERED
A ,. HITECT
OCTOBER 19, 2012
0810.03.2325
O
I_
J
z
0
z
w
z
z
0
0
CD
z
AIP NUMBER
MPROVEMENTS
>-
0
Cw
w
It
w
0
z
LI_
U
It
3-53-0058-045
SEATTLE WASHINGTON
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
FLASHING
DETAILS
A2.4
0810.03.2325
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
M TG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
SRC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
SEATTLE RESIDENTIAL CODE
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
ABBR
XX
OR XX
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
0 ROUND DUCT DIAMETER
X/Y
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
?V/ A
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
SYMBOL ABBR
SG -X
XXX
(� DNI 1L DN
O-4
0 4r-
$
Q OR Q
EQUIP ID#�
x
ISI
UP
VD
RA/EA
RG
SA
SA
RA/EA
SD
EA
MOD
NG NG
D
0
•
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE -
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL/ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
WC -1
DESCRIPTION
VOLTS
PH
<.08"WG
9"0
1,2
23
26
23
26
N/A
23
26
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS:
1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
REMARKS
WC -1
EXTERIOR
180
337
<.08"WG
9"0
1,2
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL •
SRC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.2325
3360
4
180 CFM
180 CFM
1
1. VENTILATION PROVIDED PER THE SEATTLE RESIDENTIAL CODE,
SECTION M1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R-8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING
R-8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R-8
1,3
IN CEMENT SLAB OR IN GROUND
R-5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED
TO EXTERIOR WINDOW TRIM PAINT.
THERMOSTAT/SWITCH HOURS OF OPERATION
SET FURNACE THERMOSTAT TO OPERATE 1 OF EVERY 2 HOURS.
b%3 136
MECHANICAL VENTILATION CALCULATION
PER SRC M1508.3
QF = QR / (&EGR X F)
QR = (FROM TABLE 1508.2) 90
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1
F = FRACTION OF OPERATION 1/2
QF = 90 / (1 X 1/2) = 180 CFM
OF EVERY 3 HOURS) = 1
p ��q
170 44/
(%)
RECEIVED
CITY OF TUKWILA
APR 2 6 2013
PERMIT CENTER
EXPIRES: 9/08/2014
S.M. STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 624-2777 • FAX (206) 624-2973
THE GREENBUSCH GROUP, INC
••••••••10)
ACOUSIICAI. DIO VDEO & YECNANCAL DIGINEERING
1900 GEST'tiqtN STREET SUIE 201 SEATIIE, WA 98119
(206) 378-0569 (208) 378-0641 FAX
081003.2325
0
0
Z
0
z
L!J
E• -
Z
Z
0
U
Z
MPROVEMENTS
>-
0
LU
LU
0
Z
LL
0
J
z
W
0
LU
AIP NUMBER
3-53-0058-45
SEATTLE WASHINGTON
DATE
09/19/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M 1 .0
081003.2325
STORAGE
P
/f
KITCHEN
JN
BATH
(1iL,
DINING
ROOM
(E)SG
1
(E)SG
BEDROOM
1
(E)SG
(E)SG
1� MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
SEE
OFFICE
STUDY
BATH
STORAGE
SOFFIT, REFER TO
ARCHITECTURAL, TYP
STUDY
2
LAUNDRY
NORTH
(E)SG
LIVING
ROOM
(E)SG
(E)SG
BATH
NO MECHANICAL WORK
THIS LEVEL
D
N
0
SITTING
ROOM
UPPER FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
DRAWING NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET
BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SRC M1508.6.6.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF
FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A
DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE SEATTLE RESIDENTIAL
CODE, CHAPTER M1508.5.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS
SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING
OTHER ENERGY -CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH
PROJECT REPRESENTATIVE.
4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED
AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING:
(E)SG
KITCHEN
FAMILY
ROOM
C3)
BASEMENT MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
NORTH
A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR
UNIT SYSTEM(S) WITH NEW FILTERS.
CEILING
OUTSIDE AIR DUCT,
SIZE AND ROUTE
PER PLAN
J
0_
Cl_
V)
w
z
0_
w
l
FURNACE
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
MOD, INTERLOCK
TO FURNACE
POC
FLOOR
FURNACE ELEVATION
SCALE: NONE
NORTH
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO
ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT
THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS
"WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER SRC
M1508.5.2.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET
OF FURNACE RETURN INLET PER SRC M1508.5.1.
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE
RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE
OUTSIDE/RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR.
FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME
DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED.
HARD DUCT
PER PLAN
SOFFI T
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS.
WALL CAP DETAIL
SCALE: NONE
(E)SIDING
SHEET METAL
FLASHING
2X2 BLOCKING
WALL CAP
RECEIVED
CITY OF TUKWILA
APR 2 6 2013
PERMIT CENTER
2X2 BLOCKING
2X2 BLOCKINGficiti 1414
S.M. STEMPER
ARCHITECTS
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 824-2777 • FAX (208) 824-2973
EXPIRES: 9/08/2014
THE GREENBUSCH GROUP, INC
•••••••••)))
t Auo10 sl :IES 201 3E01Eo c 9
(208) 378-0589 (208) 378-0841 FAX
0810.03.2325
0
0_
J
z
0
z
w
z
>
0
V
z
MPROVEMENTS
>-
0
w
2
w
c
w
0
z
1-
w
w
AIP NUMBER
3-53-0058-45
SEATTLE WASHINGTON
DATE
09/19/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.2325
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
03 PROVIDE 'TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH.
STORAGE
ELECTRICAL LEGEND
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
G
LIGHTING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
®
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
I I I
I 1
4
DAMPER CONNECTION
D
NON-FUSED DISCONNECT SWITCH
o
MAST, WEATHERHEAD
I J
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
®D
SMOKE DETECTOR
.1�_�-
I
ELECTRICAL METER
i
TIMER OPERATED SWITCH
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
pT
THERMOSTAT
— - —
E
CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT
®
UNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR
OFFICE
STUDY
STORAGE
LAUNDRY
STUDY
2
KITCI-4EN
LOWER FLOOR PLAN
1/4" = 1'
F
K!TCI-4EN
k
x
ID IN
ROOM
TO FtleklACE
DAMPER
BEDROOM
1
FAMILY
ROOM
Q13 -13e)
El
MAIN FLOOR PLAN
1/4" = 1'
NORTH
IXI
1_IYINC
ROOM
D<l
x
RECEIVED
CITY OF TUKWILA
APR 2 6 2013
PERMIT CENTER
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
IM !NaINE!Ra. INC
NaJMirealar anal
TM.IR&aawa
1111,1KM— 4...0
PAX all arNIS
0810.03.2325
MPROVEMENTS
0
cw
w
w
(J)
0
z
LL
ce
ceU
z
w
0
w
AIP NUMBER
5-53-0058-045
z
O
z
w
LLJ
DATE
SEPT 17, 2012
ISSUED
95%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
BCR
FLOOR
PLANS
NOTES
E1.0
0810.03.2325