Loading...
HomeMy WebLinkAboutPermit D13-140 - MARRIOTT RESIDENCE INN - BUILDING 10 REMODELMARRIOTT RESIDENCE INN BUILDING 10 16201 WEST VALLEY HY D13-140 City off ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: htto://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 0005800006 Address: 16201 WEST VALLEY HY TUKW Suite No: Project Name: MARRIOTT RESIDENCE INN, BLDG 10 Permit Number: D13-140 Issue Date: 07/24/2013 Permit Expires On: 01/20/2014 Owner: Name: GRAND PRIX TUKWILA LLC Address: C/O HEMA GANDHI , 340 ROYAL POINCIANA WAY #306 33480 Contact Person: Name: RYAN NESTOR Address: 600 W CERMAK RD, STE 2A , CHICAGO IL 60616 Contractor: Name: BARKER CONST SPECIALTIES INC Address: 8135 MONTICELLO AV , SKOKIE IL 60076 Contractor License No: BARKECS8840Q Lender: Name: WESTERN SURETY COMPANY Address: PO BOX 44450 , OLYMPIA WA 98504 Phone: 773-817-1692 Phone: 847-769-1692 Expiration Date: 09/18/2014 DESCRIPTION OF WORK: INSTALL NEW SIDING AND TRIM AS WELL AS REPAINT PER MARRIOTT BRAND REFRESH PROGRAM STANDARDS. REMOVE EXISTING SECOND FLOOR BALCONIES AND INSTALL NEW ALUMINUM GUARDRAILS AT BUILDING WALL. Value of Construction: $23,926.32 Fees Collected: $905.73 Type of Fire Protection: SPRINIC,ERS/AFA International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 0020 Electrical Service Provided by: PUGET SOUND ENERGY **continued on next page** doc: IBC -7/10 D13-140 Printed: 07-24-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: N Number: 0 Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non -Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Z.,,91rU Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or thq perfoce of wgRlk. I am authorized to sign and obtain this development pe mit and a ee to the conditions attached to this permit. Signature: Print Name: MifrtoGgr/ C��Z Date: 7 tt This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be doc: IBC -7/10 D13-140 Printed: 07-24-2013 obtained at City Hall in the office of the City • 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***PLANNING*** 9: PROJECT SHALL COMPLY WITH ALL CONDITIONS PLACED ON IT VIA THE DESIGN REVIEW APPLICATION. NO FINAL APPROVAL SHALL BE GRANTED UNTIL THESE CONDITIONS HAVE BEEN MET. doc: IBC -7/10 D13-140 Printed: 07-24-2013 CITY OF T UKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 0 1 Project No. 1/t' Date Application Accepted: OS -02-11 Date Application Expires: l l ' 02- (For 2(For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 10 King Co Assessor's Tax No.:jtp Site Address: It.02b N W . V A t1Ey 1t t4VV A.j Suite Number: IJ IA Floor: 1.1 A Tenant Name:JjAtZtalDi r- t -ttatXas(fE- 11.1.1•1 New Tenant: ❑ Yes 0...No PROPERTY OWNER Name: M'ArI DTT' ell DEANC.0 11.1 l.1 Address: tuaotw.vimte-y �.ieti..1n1 City: ,R1E State.\NIA Zip4618S Phone: ( ,10 2.... k612Fax: (e)t 1 ivrs_ itis CONTACT PERSON — person receiving all project communication Name: NA -1,1 Lles-rap., '1 Address: (.DOD W . Cia2.1vtAt. 2.17.1 sv 1 TE. —24 City: CA le_Ael0 State: IL Zip:UOlQl Phone: ( ,10 2.... k612Fax: (e)t 1 ivrs_ itis Email: t2l4ESTULQ _lam Lles rig ."orn GENERAL CONTRACTOR INFORMATION Company Name: 2:AeM Coi4%-1GULTl a LI Address: I.QUO W Cv, 1230. soTE ?4 City: GlIciscinv State: Lt..- Zip:lOcUlID Phone: r >.i(p-64` ,.Fax. /jyi102A1.0q i Contr Reg No.: y S %00Exp Date:9 1 16(N 4 Tukwila Business License No.: ottY n PA -2_ H:Wpplications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh ARCHITECT OF RECORD Company Name: NI I Architect Name: l•11GLlA I., F • 1::-.1E-IV1 Address: 333 IJotart-1 MA11i si-t n— ` re. City:S.rt. u.WoireK_ State: MIS Zip: SO 5 FSZ Phone: (1 1)43C—aPOlvFax: (tOU)430-24114 Email: M. tke.A4ZL Li kkE rki k . Corte-) ENGINEER OF RECORD Name: k�ESTIE120 & 2e5r\I Ltrv1p.ALN I Address: P.1>. t?o)c U44So Company Name: r . Nt t Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: k�ESTIE120 & 2e5r\I Ltrv1p.ALN I Address: P.1>. t?o)c U44So city:State: vV A Zip: qer-N ( oty Mp i Page 1 of 4 BUILDING PERMIT INFORMATION— 206-431-3670 -L3. %I -If -3.2' Valuation of Project (contractor's bid price): $ i Existing Building Valuation: $ Describe the scope of work (please provide detailed information): 7-1.1STAl.t_ i 1e ,.j S t Di 11r' �k1%lh Zer a .L P aciel Ar►-) 5TA tl ctilhn rt 1i e—/i 1.lT ��• arta.! E 2.140 E=lrL. SA .Gc 41GS ! 11��'/�UI NEw Alt vv (ctvAime,4jLS Ar avluoil l Et WA. Lt. Will there be new rack storage? ❑ Yes g.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below - - - _ - _- �. - — •—• Existing v.c— • v 11._, I Interior Remodel A'l.. I_J r.41 Addition to 1 Existing Structure c I".1li � %.-iPkly New 1ZI N . Type of Construction per IBC Type of Occupancy per IBC l' Floor htoGlal4l. tE C 56 4 T4Fe si p 1 2"d Floor t•100 -k i E kl 0 CIS Tire- Sl3 bizowio 124 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: N to Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in oneeof the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: E .%Si t L1.t % �� Ca tq m act: Handicap: Will there be a change in use? 0 Yes K No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes A, No If "yes', attach list of materials and storage locations on a separate 8-1/2"x II" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8.9.1 I.docx Revised: August 2011 bh Page 2 of 4 a>t • • PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O • ' : ' 1 R A iiTHORIZED AGENT: Signature: Date: 3 1 IS I t3 Day Telephone: 04-11') 1103— II,Z Mailing Address: (40D ltd. C k. 2X S 2A- (a (( j Print Name: taik J P. 1.1124f H:\ApplicationslForms-Applications On Line \2011 Applications\Permit Application Revised - 0-9-11.docx Revised: August 2011 bh City State Zip Page 4 of 4 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0005800006 Permit Number: D13-140 Address: 16201 WEST VALLEY HY TUKW Status: PENDING Suite No: Applied Date: 05/02/2013 Applicant: MARRIOTT RESIDENCE INN, BLDG 10 Issue Date: Receipt No.: R13-02189 Payment Amount: $746.82 Initials: WER Payment Date: 07/23/2013 09:40 AM User ID: 1655 Balance: $0.00 Payee: BARKER CONSTRUCTION SPECIALTIES INCL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 9868 746.82 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $746.82 546.20 196.12 4.50 ,,,nn. Dcrcin}_na Printed: 07-23-2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0005800006 Permit Number: D13-140 Address: 16201 WEST VALLEY HY TUKW Status: PENDING Suite No: Applied Date: 05/02/2013 Applicant: MARRIOTT RESIDENCE INN, BLDG Issue Date: Receipt No.: R13-01496 Payment Amount: $158.91 Initials: JEM Payment Date: 05/02/2013 12:56 PM User ID: 1165 Balance: $746.82 Payee: BARKER NESTOR, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8892 158.91 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 158.91 Total: $158.91 INSPECTION RECORD Retain a copy with permit INSP CTION NO. - PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Pro OWN ct: I . ° Typ of Inspection: 6j, \b, Al 1". • Addre s: 16:)siDate Called: Special Instructions:. IDRequester: / Date Wanted: t(—`+ -f cZy »' p.m. Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: pgiuCT-aittfier,e_ Inspector: r Date. 1.4-13 REINSPECTION FEEQUIRED. Prior to next inspection. feemustbe paid at 6300*Southcenter Blvd., Suite 100. Call to schedule reinspection. ,.i L GENERAL NOTES ARCHITECT'S CERTIFICATION CONVENTIONS PROJECT CONTACTS 1. ALL W0RK SHALL COMPLY TO ALL LOCAL CODES AND ORDINANCES. 2. NO WORK SHALL BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES. 3. ALL WOR)000SHIP. METHODS. ARD MATERIALS SHALL EXPLICITLY COMPLY WITH APPLICABLE INDUSTRY STANDARDS. ANY DEVIATION FROM SUCH STANDARDS MUST BE APPROVED BY OWNER AND ARCHITECT. THE ABSENCE OF A DETAIL OR PARTICULAR METHOD OF CONSTRUCTION FROM THESE DOCUMENTS DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF COMPLYING KITH THESE STANDARDS. 4. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE AND CONSFJIT OF THE OWNER AND ARCHITECT. 5. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING WITH CONSTRUCTION AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES. 6. ALL WORK SHOYK HEREIN I5 91E0' EXCEPT WORK SPECIFICALLY NOTED AS 'EXISTING'. I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED BY ME OR UNDER MY DIRECTION AND THAT TO THE BEST OF MY KNOWLEDGE COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. LOLIIAEL F. DIEM 999.1 6654 ARCHITECT 11/19/14 96/1191109 91 119 4 0 x -x 941 T6 Nrm =01 1011901L MED 693 Y..9 611¢ PPM= MON 1013111 MICRO Cr 10. 031106 600.1 Meal to 6639611 010111 DO. E7m.11AmL 011. omYc 99. 01 90111100 1110191 99001. 91 MIZE IDEP.L . 1191 ort WOO. 91 MBI 901119010101 p®0 6T Yzt �.. I E. ONE 090 TAO OL MAR m. MRM Ylt. 176 9 RIO 5.0. 1m t0. FS not >: 11 MB SAM CUL CM m WA T 5x004WW1 MC lux 1m116N1 90 - CCM 09015 11 9.0611E 01 Wim¢ 00.01 ennui 1909 1191 WM CM WOO 91 09019 w ILEX 000 906001 • L 10.01x0106 t MAN 9...OA ]. 4m wenn 1 1119912111.0 m LL L01011/ 000191/01 11 s 00 0010 01 Y0M04 00001 PROJECT ODER 000 01005/00 /MN= OR ROOK. PROJECT TITLE: .united Exterior ior Renovations Residence Inn IL20L West Valley Highway Seattle (A IALAA ARCHITECT: ftrg Tukwila Michael F. Diem 333 North Main Street = .Seita *2CI Stillwater Minnesota SEW REVISIONS No changes shall be made to the scope of work without prior approval of • Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 1 PLANNING APPROVED • No changes .can be madeto these plans without approval from the Planning Division of DCD Approved By: 1?ViNe Date:�.--- SEi'ARAT E PERMIT R OUSRED FOR: Er Mechanical [iectricai GiMumbing Cki"4ds Piping City of Tukwila BU r'ING DIVISION FEMME MI TAMA 16201 IMT 4011M 100/1O TALLA010166 III: (125) 016-500 RTW 6559 60012711 05. ow= L 60616 114 (647) 753-102 FAX (647) 761-16/ EWL' 0E70)061001110:61 500145.CEN 133 5094 YAA7 STREET 510 /205 101 5500 1E1, (651) 430-006 551 (651) 470-2414 VICINITY MAP FXLE COPY Permit No. Vt! 140 PPi0 rr'view approval is subject to errors and omissions. k° fir, of constuc6on documents does not authorize v ..4ation of any adopted code or ordnance. Receipt of approved Field Copy and conditions is acknowledged: By /0-4j7 Date: -7/2?-71/ City Of llukarila BUILDING DIVISION APPLICABLE CODES 2009 INTERNATIONAL BUILDING CODE DRAWING INDEX ARCHITECTURAL CS PROJECT NSORYATNT) Al DEYOl1TN)N PLN, CONSIRIICHOR PLAN. F.1(IERIOR ELEVATION & DETAILS PROJECT INFORMATION 99700 5IDEED CCCUPN6T: 00P 6-1, 1010. O 50001 PR16O S Do71PORT: 0013 R-1. 4001 MO 01 9000: NO 91DMG TAPE CI:MR 0W 513E 58 10100ETED MOA 350 50. F1. (36 171060 A10NES) 001PN4T LMR LESS 1111 10 PEOPLE SCOPE OF WORK 5. DEMO 009114 900 BUOY WM 0(36) WOMBS NO 1010.E 0050 SIZE M 00401101-96RtD OOP5TET1 L PM01 51010 OR MOO 6101001 0 000IOD. DAR �2 1 FROM NO 66011. PROMO 01019 K771R [RIMED 545 POSTS PRAP AXED /10 PNE "-FN3RO.0.141045 BEMEER �D 12135 t POIOFPLOOED 10 1001 DAM 515201. 4. M114651 00030 51501110 0 0 PROM (647)667'003 500.359019.0» 01 050 W9R1T-APPOMD HALM STOOP 16/001 NO RET OR MUD ALL LOCA CODES 010 MOMOM FOR 51ROCIUBL COCIT5 N0 AOA IEDUR10M2 090055. 0001 113 NGF 54003-103 WOOED MOL TOP RE 0155 1570 OMI 201000 014-1053 17010041UL 101100 RAL 001 NS 011 7M00ESS. ND 6 6 t. MIN. PC E1S 014 467 OWL 15 DESS N AL 3 55/16' SPN10 0114 100010 ALM MOOS NO ACCE550160. OWL 1110003 16711 0356. MOM10 CORM= 1 Y O A MUNEAUX O 55154 .TmDAL 110.1000 005410 TO EABLSDR CAST MK 909075 05156100400.653 OMA 06D1RN 91010 OF 417 OL MORAL 010900 0 IDP NO 605500 OF SON 0165 TO ROM 10 40061 OU, ROOM 0 00643. N1 MAC OMPORMI5ID 9: P000FR000 SIETE 10 MEET MMN NMA 16134-05 0110413. 110 �ECEPP110 NJ. 51/410 STOP N0 WONL El55 1ST 011004 P0515FASTENERS 1/4101.001.17. 10 1070SED FASIDERS NIE KNITTED " 5TRUCIU . OR 194.0.1 MOM 10 401010E REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 2 2013 City of Tukwila BUILDING DIVISION WW1 WM SONG 0 151 MUM NO ll) 51/M. 961 1. (11) 91S1*00710.5. (1) MOOSE (1) P034/014155 2. 0 COMM OMR 5030 LOCA1001 KKK DODO[ BOM 115 NO NOM LOOSE /116 01 COMM SUMMATE RF76M 0®01 5500 151E N WORCTO-99AOD 00331016 • 0 COMM snicco PAM 510C 1.00004. SECUK LOOSE 1105 ID 01500 SLOSMATE AS MUM. 4. MINIMI. 110 PREEIMED NOM ORP FUSING ME 1005 OF 6000 NO 000. NATE 911.1 6N51 00107 10191106 0 605. NO MDU 1009 ffiM 1000316 5. 6601 5/I4- 67)0 0000 coal 599 MEM X10 ROIL P VP UP096i ' 6. EL SEIC TO 950NA 11 (1) WO OF IL 5010 5500 N ROD PER REZONE 914 PI�µ 5 7. suD 8000 W 0 MED BIN Eo6TR1TUR AO0OS 10 3116010 SDK BONG 560.01 A10 9005-1440 PER SDI: YANPACDAFTS 9001x0050 Mi 0601. OIL PQM 10 BE SET NO CAULKED PRO( TO 0IID-3090 MA CW OF PWT. & F61L S 100 METAL 1/5010 ®OD F/OI SONG MEL BUR ENT NO FUJI OAK E/OI 1111. Y. Of WOOL EOM 0031 0001142 MON 501 OMR (1) FED -011510W 017 Pelt 5110001 390 MIX 10 N 00710 00150E 000 111 151557106. 0611 5/11 X E x0' *0-90001 OMIE 11115 11709 01RI0000 11499DIN. 11. N 93060 74*1 1011 L0 400. MOD. (1) 1/76 x SN' PIE-FRBEO 500074 FSR 01916501 OVER 0100 T011 010 (1) 5510-15090/ ROI 0511 OF PAM. 12. N 9111 BOM 100206. MULL (1) 7/16 5 17 PR -50190 5110014 FRO MEM TBI OVER COSMO TRY OO (1) FIID-5060 RAL 0o OF NM. 11 PRP ND RST -R/NT AIL PORED©moons40».ND 5000 FIOR 0003/00401005 1. 10 6T PONT It 01 D GMT 10 0006 W 00 FOES. • 15 M00I REP NO RE -PANT MOM WOW MOPS ND SMITS MD 160110006 SALM TM DPI MANS 16 PGE ML NO4 MEWL. NO PAM 11711 MO CWS 0 MOM M I MC INR MBR N 0000 AM OLIVE) N THE 1®U0E MI 017094 DORY. 1 BY W06R. 17. PULING 0090 555701 1)0002110 0 10501 0.1900 /11114 14115 BY 550 (51000 NAL Alb). MOM OR 0BER URAL /PROVED MOAT ODOR 0501 (2) 1681 0506 (4 M. RT RII 11603E55 DO CW OPER 57009). 16 ROOE AAD 945611 Ex64G 1101001.115. PPM 00016/055 TO WM 50 MC 0 1011 COOL 19 RPI/ /11 SE/LOIS MUM AIL F06TRAIO6 NO .0000 0®91 1007[13 26 RE -50E NI 0070 00 WINDS 10 100 BLOMC MC. PRF. RE -CAM. NO RE -PONT COSTAL 0B*Er 74113. 21. N1 95//16 AW MU 0A1WM3/ACJ)ESSa10 10 E ARON BY 16110 SEEMS 0 ODER EMIL MOOT 000.11 mom. RECEIVED CITY OF TUKWILA MAY 0 2 2013 PERMIT CENTER 40 g 1 1 PROFESSIONAL SEAL 6654 REGTSTERED ARCKTEOT , Npp(1E507EA4 SOATEOF WASHINGTON SHEET NUMBER: D 19)i Lio ".4 1 .1C -f* ab ma) rr IMO COMIC Woo Pan MEI. ,I 077.7 les a IIEOE0 t x,10. MII (3), 1/2 ease SW —n 1ffi. toot MEW. Era..), lam 1/i.ra' 16—IpOar 0 0 0 440 .4 A105 PROPOSED EXTERIOR ELEVATION SCALE: M.T.S. YfLVf W1.1 1lnCbmiSS III AIN >y IC. ALL owe 0.N 1 Yeti 111.1. latJ '. 0 0 A104 PROPOSED BALCONY RAILING ELEVATION SCALE: 3/8•-1'-0• A103 PROPOSED FRENCH BALCONY PLAN SCALE: 1/0-1'-0• L 0 2 4 0 1.4 4, TYPICAL OF 18 BUILDINSS S ► ,•'%k4‘1k ��1111�1 1 BALCONY BALCONY to8122 I4‘ ‘ 4W � / ♦` oft. .... ... 0 A105 EXISTING EXTERIOR ELEVATION SCALE: ! N.T.S. SUM om n A102 EXISTING BALCONY DEMO PLAN SCALE: 1/4••1'.0' 0 2 4 :i A101 EXISTING SITE/KEY PLAN SCALE: N.T.S. CODE ANALYSIS Job Aede¢ 16201 W=V.Oey If .O1 Sado WA 98161 AW folie fix haermml Baldy Cale X09 Us Camp Had CmairtimType: Type 5S Stries J Slodb. M fia(emab) Spmlfec Yb O=qm lod Imthb ID mph. S.amd Lads: 3161313.6 t entree =mike and panel. del be traged assist. 6.6d50Da pa lima bel e' mr dveake aldeIcy =d tlandabnlad OroQbgpaodde imam Theydl.Do wig . (aIle emtoa.id lad d200 Od ggted is cy imam 1 1 MATERIAL SPECIFICATIONS nrmhked Abm6.a n0ep .tb.b.bb 1. Abom.Oad.D Systenbbe by Pala O147J8676301pae03/ dmea aha Sdmimrppad revsryom"mar =I beaEmceed dbd aka bdohm. ben.mrd wady and ADA Guarani Syne bb..e.meSbpcarded don top m7 rimdm6' M diol Owollemaid.bm bomb nil 'tit Y76'o0 di11,a, 0131 16-6 H'.Imn r as with .067'.60&mama mm J I3/16' crag vitt =aim Awn hoaaad =maim Abet Badd moo be i 2 N' Kae.6.1ri'..0thiches da pea ups. AlalTtgemWaalb he pmelamied.hia b commie= AAMA 260405 Simard Use m tela ted fiat= thbogt°a H. aped fimae3 ae pemRd u de lye= amp *mbar bpbdham Social kudzu bacme pmbd maw moms REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 2 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 0 2 2013 PERMIT CENTER W1A PROPOSED EXTERIOR RENOVATION FOR: w J 1- -w N a a 1 1 1 PROFESSIONAL SEAL SHEET NUMBER: Al OF ��ILA �, ,• ' ��, y//�� City of Tukwila Jim Haggerton, Mayor O`.r.'� ' 1�j Y � ,� Department of Community Development Jack Pace, Director x 9oa May 14, 2013 Ryan Nestor Barker Construction 600 W Cermak Rd, Ste 2A Chicago, IL 60616 RE: Correction Letter #1 Development Permit Application Numbers D13-132 thru 150 Marriott Residence Inn Bldgs — 16201 West Valley Hy Dear Mr. Nestor, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Planning Department. At this time the Building, Fire, and Public Works Departments have no comments. Planning Department: Brandon Miles at 206 431-3684 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. File No. D13-132 thru D13-150 W: (Permit CenterlCorrection LettersI20131D13-132 thru 150 Correction Letter #1.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 DATE: PROJECT NAME: PERMIT NUMBER: ADDRESS: ZONING: PLANNING DIVISION COMMENTS May 13, 2013 Marriott Residence Inn D13-132, 133, 134, 135, 136, 137, 138, 139, 140, 141, 142, 143, 144, 145, 146, 147, 148, 149, and 150. 16201 West Valley Hwy TUC The Planning Division of DCD has reviewed the above permit application. The permit application cannot be approved. 1. The proposed work is within the shoreline jurisdiction of the Green River (within 200 feet of the ordinary high water mark). The property is zoned Tukwila Urban Center and under TMC 18.28.070 design review is required for all work within the shoreline jurisdiction in which the exterior work value exceeds 10% of the buildings' assessed valuation. According to the building permit application submitted, the cost of work will be $454,600.08 (19 x $23.926.32). King County notes that the total assessed valuation for the buildings on the site is $3,287,900. Thus, the proposed work is 13.82% ($454,600.08/$3,287,900) of the buildings assessed valuation and design review is required before issuance of the building permits. The design review application is attached. Please note that since design review is triggered all landscaping on the site will be required to come into conformance with the City's landscaping requirements (unless a waiver is granted) and all signage on the site will also be required to come into conformance with the City's sign code. ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: <D13-140 DATE: 07/11/13 PROJECT NAME: MARRIOTT RESIDENCE INN, BLDG 10 SITE ADDRESS: 16201 WEST VALLEY HY Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 2 Revision # after Permit Issued DEPARTMENTS: Building Division ❑ Public Works ❑ Fire Prevention Structural trek iito ■ Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ❑ DUE DATE: 07/16/13 Not Applicable ❑ Permit CenterUse Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route IT' REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 08/13/13 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: 110 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-1'10 DATE: 05/02/13 PROJECT NAME: MARRIOTT RESIDENCE INN, BLDG 0 SITE ADDRESS: 16201 WEST VALLEY HY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Building Division ■ Public Works OCi . 13 Fire Prevention Structural POI d'wie4 .Planning Division nPermit Coordinator 0x.17)-13 ■ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete IA Comments: Incomplete n DUE DATE: 05/07/13 Not Applicable ❑ P,erinit Center.Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 14 REVIEWER'S INITIALS: Structural Review Required n No further Review Required n DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/04/13 Approved n Approved with Conditions n Not Approved (attach comments) [7J Notation: REVIEWER'S INITIALS: DATE: Permit CenterdUse Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping PW ❑ Staff Initials: J\ ` City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 110 l 13 Plan Check/Permit Number: D13-140 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner RECEIVED CITY OF TUKWILA JUL 1 1 2013 PERMIT CENTER Project Name: Marriott Residence Inn, Bldg 10 Project Address: 16201 West Valley Hy Contact Person: Ryan Nestor Phone Number: 847 763-1692 Summary of Revision: -PIA ki k1 4-1A-\10. Prt)M W t Tl1 p v1/44-1 i DC- M L1 I . Sheet Number(s): 'A - L\.e \-)1A-L1 Uei� "Cloud" or highlight all areas of revision including date of revision M,1/4 1)e- Received Je Received at the City of Tukwila Permit Cen -r by: Entered in Permits Plus on V l C:\Users\jennifer-m\Desktop\Revision Submittal Form.doc Revised: May 2011 Contractors or Tradespeople Pester Friendly Page 1 General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company BARKER CONST SPECIALTIES INC 8477691692 8135 Monticello Avenue Skokie IL 60076 Out Of State Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 603234396 Active BARKECS884OQ Construction Contractor 9/18/2012 9/18/2014 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status BARKEMC870DL BARKER MORRISSEY CONTRNG INC Construction Contractor General Unused 4/4/2013 4/4/2015 Active BARKECS958P5 BARKER CONST SPECIALTIES INC Construction Contractor General Unused 10/25/2005 10/25/2007 Expired Business Owner Information Name Role Effective Date Expiration Date TILEV, SHAWN Agent 08/30/2012 Amount BARKER, KEVIN JAMES President 08/30/2012 MGL0175088 NESTOR, RYAN PAUL Secretary 08/30/2012 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 Western Surety Co 71324822 09/18/2012 Until Cancelled $12,000.00 09/18/2012 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date Mt2 Co Hawley Ins MGL0175088 02/18/2013 02/18/2014 $1,000,000.0003/11/2013 Mt1 Co Hawley Ins MGL0174849 02/18/2012 02/18/2013 $1,000,000.00 09/18/2012 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 07/25/2013