Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D13-174 - SILA SOLUTIONS - TENANT IMPROVEMENT
SILA SOLUTIONS 6840 FORT DENT WY D13-174 City a. Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 2954900425 Address: 6840 FORT DENT WY TUKW Suite No: Project Name: SILA SOLUTIONS DEVELOPMENT PERMIT Permit Number: D13-174 Issue Date: 05/29/2013 Permit Expires On: 11/25/2013 Owner: Name: PEPPERWOOD HOLDINGS LLC Address: 2835 82ND AVE SE #300 , MERCER ISLAND WA 98040 Contact Person: Name: REBECCA DAVIDSON Address: 2835 82 AV SE, SUITE 300 , MERCER ISLAND WA 98040 Contractor: Name: D P INC GENERAL CONTRACTORS Address: 19909 BALLINGER WAY NE , SEATTLE, WA 98155 Contractor License No: DPINCGC066BU Lender: Name: JOHN C RADOVICH DEVELOPMENT Address: 2835 82 AV SE, SUITE 300 , MERCER ISLAND WA 98040 Phone: 206-267-2669 Phone: 206-361-2989 Expiration Date: 01/31/2014 DESCRIPTION OF WORK: TENANT IMPROVEMENT EXPANSION OF AN EXISTING OCCUPIED SUITE TO INCLUDE: DEMOLITION OF CASWEORK AND PARTITIONS, CONSTRUCTION OF PARTITIONS, DOORS AND RECITES, RELOCATION OF EXISTING AND INSTALLATION OF NEW LIGHT FIXTURES. NEW PAINT AND FLOORING THROUGHOUT EXPANSION AREA TO MATCH EXISTING SUITE. NO STRUCTURAL WORK. NO ALTERATIONS OF CORE. Value of Construction: $45,000.00 Fees Collected: $1,460.87 Type of Fire Protection: SPRINKLERS/AFA International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY **continued on next page** doc: IBC -7/10 D13-174 Printed: 05-29-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non -Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: O '7j , I hereby certify that I have read and e ami d this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied th, hether specified herein or not. The granting of this permit does not presu e to » 've authority to violate or cancel the provisions of any other state or local laws regulating construction or�tFig�erformance •f • k. I am : uthorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: (,{j�: % [ ,� �% , /� Date: Print Name: E -c29-13 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non -building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D13-174 Printed: 05-29-2013 7: All construction shall be done in confo ` e with the approved plans and the require is of the International Building Code or International Residential, International Mechanical Code, Washing tate Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ***FIRE DEPARTMENT CONDITIONS*** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 25: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress doc: IBC -7/10 D13-174 Printed: 05-29-2013 travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or t path of egress travel is not immediately visible to the occu . Exit sign placement shall be such that no in an exit access corridor is more than 100 feet (30,480 mm) olisted viewing distance for the sign, whiche, ,is less, from the nearest visible exit sign. (IFC 1011.1) 26: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 27: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1006.1, 1006.2, 1006.3) 28: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 29: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 30: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinlder heads. (IFC 901.4) 31: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 32: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 33: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 34: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 35: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 36: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NEPA 70) 37: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 38: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 39: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 40: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. doc: IBC -7/10 D13-174 Printed: 05-29-2013 CITY OF TUK41101 Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Perm No. Project No. Date Application Accepted: 5-1 . 1- t 3 Date Application Expires: \ ` - 11 -1 3 b3,1 (For, office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 2954900425 Site Address: 6840 FORT DENT WAY, TUKWILA, WA Suite Number: 375 Floor: 3 Tenant Name: SILA SOLUTIONS PROPERTY OWNER Name: John C. Radovich Development Company Address: 2835 82nd Ave SE City: Mercer Island State: WA Zip: 98040 CONTACT PERSON - person receiving all project communication Name: Rebecca Davidson Address: 2835 82nd Ave SE City: Mercer Island State: WA Zip: 98040 Phone: (206) 267-2669 Fax: (206) 267-6061 Email: rebeccadavidson@jcrdevco.com GENERAL CONTRACTOR INFORMATION Company Name: DP INCORPORATED Address: 19936 Ballinger Way NE City: Seattle State: WA Zip: 98155 Phone: (206) 361-2989 Fax: (206) 362-3665 Contr Reg No.: DPINCGC066BU Exp Date: 01/31/2013 Tukwila Business License No.: BUS -0994280 FI:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh New Tenant: ❑ Yes ®..No ARCHITECT OF RECORD Name: Company Name: rn f Yl0 viPVAV d t/GJ Architect Name: Addre 3c '7 Address: City: Af t,�/v City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Company Name: rn f Yl0 viPVAV d t/GJ Engineer Name: Addre 3c '7 Address: City: Af t,�/v City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: rn f Yl0 viPVAV d t/GJ -�_-a _— Addre 3c '7 + 03 �1�(,Ziip:C/S/A City: Af t,�/v -e4a. State: (AA Page 1 of 4 BUILDING PERMIT INFORMATIO.06-431-3670 • Valuation of Project (contractor's bid price): $ 45,000 Existing Building Valuation: $ 8,201,300 Describe the scope of work (please provide detailed information): TENANT IMPROVEMENT EXPANSION OF AN EXISTING OCCUPIED SUITE TO INCLUDE • DEMOLITION OF CASEWORK AND PARTITIONS • CONSTRUCTION OF PARTITIONS, DOORS AND RELITES • RELOCATION OF EXISTING AND INSTALLATION OF NEW LIGHT FIXTURES NEW PAINT AND FLOORING THROUGHOUT EXPANSION AREA TO MATCH EXISTING SUITE NO STRUCTURAL WORK • NO ALTERATIONS OF CORE Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? ❑ Yes FIRFPROTECTION/HAZRDOUS MATERIALS: Sprinklers Automatic Fire Alarm Handicap: ❑ No If "yes", explain: 0 None ❑ Other (specify) Will therebe storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 'l No If 'yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Sa, ty Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC i' Floor 20,270 2,533 0 0 V -B SPRINK B -OFFICE 2"d Floor 20,270 0 0 0 V -B SPRINK B -OFFICE 31d Floor 20,270 0 0 0 V -B SPRINK B -OFFICE Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? ❑ Yes FIRFPROTECTION/HAZRDOUS MATERIALS: Sprinklers Automatic Fire Alarm Handicap: ❑ No If "yes", explain: 0 None ❑ Other (specify) Will therebe storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 'l No If 'yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Sa, ty Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE L S OF THif ATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD Signa Print Name: O' A�THAMOR/ I riRli Date: Day Telephone: Mailing Address: 435. •AkteL---tTn iA/k' city H:\Appltcanons\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9-1 Ldocx Revised: August 2011 bh State 3 Zip Page 4 of 4 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 2954900425 Address: 6840 FORT DENT WY TUKW Suite No: Applicant: SILA SOLUTIONS RECEIPT Permit Number: D13-174 Status: PENDING Applied Date: 05/17/2013 Issue Date: Receipt No.: R13-01658 Initials: WER User ID: 1655 Payment Amount: $1,460.87 Payment Date: 05/17/2013 10:04 AM Balance: $0.00 Payee: PEPPERWOOD HOLDINGS LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 002474 1,460.87 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $1,460.87 882.65 573.72 4.50 rinn• DnnninLAA ',Tinto AR -17-1(11Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. //f CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project ..1/4_,Type ¶A S, 10 I `'js of Ipspection: f-, a At, 1 11(16•'16 Address: . (9''4 (0 --r- il) A,/ - Date Called: Special Instructions: -- Date Wanted: �' ( 3p.m. Wim.. Requester: Phone No: 0�pproved per applicable codes. Corrections required prior to approval. COMMENTS: ref or( Inspector. ►� u Date V ( 3 1 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 iv., (206) 431-3670 Permit Inspection Request Line (206) 431-2451 r3- (7f Projects, {I /. •-....._^. /3 Type of Inspection: L -,‘:)..5 - Address: Date Called: f.- Special Instructions: `/' Date Wanted: " ` _a.m- p.m. Requester: PhoneNob 1-7-7 -17-7 , Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspet\r: at“ t Date: n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD "Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ka, (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: -`S, , a < \ A_ S D (v (:U,v Type of Inspection: r� U.1�s Address: C, K43 Date Date Called: [p/Y E*- Special Instructions: Date Wanted la�tf'i' -;(� �� p.m. Requester: Phnpet o(^ 3 q 6 ,,v -i% Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: Date I ( v n REINSPECTION FEE R Q IR rior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. r � / INSPECTION RECORD �4 (�" Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 p— (206) 431-36 Permit Inspection Request Line (206) 431-2451 Project: , j s . I 4- . `' L vr. U ` Type of Inspection: ‘ s Q s. 6.1-...` 1.... /I 0, Nie,e A. sr, (e_J 6-0,1-ef Address: - Date Called: Co -g0 EDi1DL/t Special Instructions: ,f , Date Wanted: Co -<2-/3 ..._--a...._ . P Requester: Ph one No; 3% _2"/ 7k es Approved per applicable codes. , Corrections required prior to approval. COMMENTS: 0, Nie,e A. sr, (e_J 6-0,1-ef (9 i\Je_e P.), r.-, .:..E.,:it ,\, 63tici Inspector: REINSPECTION FEE REQUIRED. Peior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100: Call to schedule reinspection. Date:, INSPECTION NO. INSPECTION RECORD Retain a copy with permit 13-/74 PERMIT N0: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ' (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Proje \ j, (� Typg_of Inspection: rI-A-A,A6 I v r . \ S--) (� Address:Date 0 (0E-40 -- , Tr -6 EAT Called: Special Instructions: �f Date Wanted: 2; ,/"a.m.. -(3 ,.p.m. Requester: , Phone No: G `" 3 %% -2-.'7'7. Approved per applicable codes. Corrections required prior to approval. COMMENTS: —moi r reiJS � c { 11111 A REINSPECTION FEE REQUIRED rior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Ispector: Date: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: rt �G 1(ji Jl� Typ(�f Inspection: . i it. l 'tilt/— Address: / 01� Suite #: C� i..� 9Q�- Contact Person: Special Instrucct?rhs: Permits: Phone No.: proved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: �//\ ..5—? Date: 7//// S Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 013-17V.. 13 -F -/S7 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Proje : �� a .o! a ll/on S Type of Inspection: rn 1" l not / Address: Suite #: �;gya / r12,IIJP Contact Person: Special Instructions: Pre -Fire: Phone No.: rYApproved per applicable codes. Corrections required prior to approval. COMMENTS: ff Fire_ /QP/1'1 r► �IGY / © � Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: • Inspector: k" Fret y Date: 7/s'/3 Hrs.: / , d $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 3--5-/3R PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: S hot .Sidu it/ 0 Sprinklers: Fire Alarm: Type of Insp ion: S r 1 n �(�f Civ Address: Suite #: 6 o /-cr / &I.' 14) Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: aK couee- Ad Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: (.9 'L rmS"y Date: /Z/ /i 3 Hrs.: I t $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 NOTICE TO CONTRACTOR CONSTRUCTION CONTRACTOR'S RESPONSIBILITY' Before bidding or starting any construction work, you are required to obtain a written asbestos report from the building owner or owner's agent. The report must be based on a survey by an accredited AHERA building inspector unless the building owner assumes materials in the structure are asbestos or has other convincing documents showing asbestos is not present in the work area. A building owner may know asbestos has been removed during prior work or that a new building has been constructed using materials certified to be asbestos free. If you discover suspect asbestos materials, you must report them to the building owner within 24 hours. Asbestos materials may be found in enclosed structures or between other materials, where they are not accessible before work. State law specifies a minimum $250 per day fine for failure to obtain the asbestos report. This fine can be applied to both the contractor and building owner. Additional fines may be applied if workers are exposed to airborne asbestos. Washington State Department of Labor & Industries regulations & policy with regards to asbestos removal. A Copy of the asbestos report must be made available to the building inspector prior to the first inspection. In addition, if asbestos has been found, confirmation of the completed abatement work must be provided to the building inspector. Inspection scheduling will not be accepted until this documentation is received by the building inspector. 41 0, PERWT GO COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-174 PROJECT NAME: SILA SOLUTIONS SITE ADDRESS: 6840 FORT DENT WY X Original Plan Submittal _ Response to Correction Letter # DATE: 05-17-13 Response to Incomplete Letter # Revision # After Permit Issued DEP RTME TS: Building Division AV Public Works SIA N//� ire Prevention Planning Division Structural Permit Coordinator u DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05-21-13 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06-18-13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 PLAN REVIEW CHECKLIST - (Nonstructural) By: Date: cs 23-1.7 Permit App. /D / 7 - /7 L/ IBC Edition If? & State Amend. Project title: s / L,4 �Q /Gtr`/cI •�1' +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Q Classify the building or portion thereof in accordance with Chapter 3 Q Determine the type of construction of the building in accordance with Chapter 6. • 0 Determine if the location of building on the site and clearances to property lines and other buildings on the site plan are in accordance with code provisions. Q Review for conformity with General building height and area limitations in accordance with Chapter 5. Q Review for conformity with special detailed requirements based on use and Occupancy. Q Review for conformity with Type of Construction requirements of Chapter 6. Q Review for conformity with Fire and Smoke protection features of Chapter 7. Q Review for conformity with requirements of interior finishes of Chapter 8. O Review for conformity with requirements for fire protection systems of Chapter 9. • Review for conformity with requirements for means of egress requirements of Chapter 10 O Review for conformity with requirements of accessibility in accordance with Chapter 11, and ICC A117.1 O Review for conformity with Washington State Energy Code. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ✓ In circle = topic has been reviewed for the application. X In circle = topic is not relevant to proposed scope of work. Contractors or Tradespeople inter Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name D P INC GENERAL CONTRACTORS UBI No. 601515833 Phone 2063612989 Status Active Address 19936 Ballinger Way Ne License No. DPINCGC066BU Suite/Apt. License Type Construction Contractor City Seattle Effective Date 1/31./1994 State WA Expiration Date 1/31/2014 Zip 98155 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status PATTICC034MH PATTISON CONSTRUCTION CO LLC Construction Contractor General Unused 7/8/1997 2/17/1998 Archived PATTICA066DQCONSTRUCTION PATTISON & ASSOC Construction Contractor General Unused 3/18/19942/17/1998 Until Cancelled Archived DODSOPI101J6 DODSON PATTISON INC Construction Contractor General Unused 4/2/1990 3/26/1994 Archived ACECO"179L0 ACE CONSTRUCTION Construction Contractor Carpentry/Framing Painting/Wallcovering 6/20/1983 6/16/1986 Archived VANSND'176B0 VAN'S NORTHWEST DRYWALL Construction Contractor Dry Wall Painting/Wallcovering 1/20/1983 11/1/1983 Archived ALLAMD'1846N ALL AMERICAN DRYWALL Construction Contractor Dry Wall Painting/Wallcovering 1 /15/1982 1 /15/1983 Archived Business Owner Information Name Role Effective Date Expiration Date DODSON, WILLIAM President 01/31/1994 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 6 Merchants Bonding Co (Mutual) WA28622 01/31/2013 Until Cancelled $12,000.00 12/27/2012 5 DEVELOPERS STY & INDEMNITY CO 791078C 01/31/2008 Until Cancelled $12,000.00 02/25/2008 4 CBIC SA6377 01/31/2002 01/31/2008 01/31/2010 $12,000.00 01/09/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 17 Travelers Indemnity Company Th C0526D6516 01/31/2013 01/31/2014 $1,000,000.00 01/30/2013 16 Charter Oak Fire Ins Co CO2B323322 01/31/2013 01/31/2014 $1,000,000.00 01/22/2013 15 DTCO2B323322C0F12 01/31/2012 01/31/2014 $1,000,000.00 01/02/2013 httns!//fortress.wa.gov/lni/bbin/Print.asnx 05/29/2013 SILA-DE—PL-03.dwg N tn c 0 0 -Ei5 0 rox w J � N N C LL 0 o o , iCD LJ -Q I CD M CO 0 m c. ��� CL -� � c,>-15. II LL Mr00' N u52',c ��cIIie°L) DI=v)o> DECK ti = u rr FEC - D IT.... / _ n 11 n \\ I F-----r- i i rr O 2 \\ R6SE� DEMOLITION LEGEND DEMOLITION PLAN 1/8" = 0 5' 10' EXISTING BUILDING CORE TO REMAIN. EXISTING CONSTRUCTION TO REMAIN. EXISTING CONSTRUCTION TO BE DEMOLISHED. DEMOLITION KEYNOTES OEXISTING CASEWORK AND PLUMBING TO BE REMOVED. SALVAGE SOLID SURFACE COUNTER TOP AND CABINET PULL HARDWARE TO BE REUSED. SEE CONSTRUCTION PLAN 2/TI-2. 0 0 EXISTING CORRIDOR DOOR AND DOOR FRAME TO BE REMOVED. EXISTING CEILING SOFFIT ABOVE TO BE REMOVED. PATCH CEILING GRID AND CEILING TILES AS NEEDED TO MATCH ADJACENT. A SECTION OF THIS EXISTING PARTITION IS TO BE REMOVED TO CREATE AN OPENING IN PARTITION. SEISMIC BRACING EXISTS IN LOWER PART OF EXISTING PARTITION. SEE ELEVATION 1/TI-5 FOR DIMENSIONS. REMOVE EXISTING LIGHT SWITCH. PATCH AND PREP PARTITION TO RECEIVE NEW PAINT. EXISTING STORAGE SHELVING TO BE REMOVED AND SALVAGED' TO BE RELOCATED IN NEW STORAGE ROOM. COORDINATE WITH TENANT. OREMOVE EXISTING WALL MOUNTED SECURITY MIRROR AT THIS LOCATION. PATCH AND PREP WALL TO RECEIVE NEW PAINT IF NEEDED. 20' 30' ° NORTH DEMOLITION NOTES 1. A CLEAR PATH OF EGRESS TRAVEL SHALL REMAIN OPEN AT ALL TIMES DURING DEMOLITION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES AND THE BUILDING MANAGEMENT. 3. ALL DEBRIS SHALL BE REMOVED FROM THE CONSTRUCTION SITE DAILY. 4. ALL DEMOLITION SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING MANAGEMENTS RULES AND REGULATIONS WITH MINIMAL DISTURBANCE TO OTHER TENANTS. 5. THE CONTRACTOR SHALL PROVIDE DUST BARRIERS FOR PROTECTION OF EXISTING ADJACENT AREAS. ALL HVAC SYSTEMS ARE TO BE PROTECTED DURING DEMOLITION. 6. THE CONTRACTOR SHALL NOTIFY THE OWNER AND MSA OF ANY DEMOLITION WORK THAT IMPACTS THE STRUCTURAL INTEGRITY OF THE BUILDING. 7. THE GENERAL CONTRACTOR SHALL IMMEDIATELY REPORT ALL ACCIDENTS, ERRORS OR DEFECTS TO THE BUILDING MANAGEMENT. OFFICE (EXISTING) 1 304 1 - OFFICE (EXISTING) 305 (- OPEN OFFICE OFFICE (EXISTING) 301 A a OPEN OFFICE OFFICE (EXISTING) 300 I OPEN OFFICE 300 A a CONSTRUCTION LEGEND 0 CONSTRUCTION PLAN 1/8" =1'-0" 10' EXISTING BUILDING CORE. EXISTING CORRIDOR PARTITION. EXISTING B/S DEMISING PARTITION. EXISTING B/S TENANT PARTITION. EXISTING CHAIR RAIL. NEW B/S CORRIDOR PARTITION. SEE DETAIL 7/TI-1. NEW B/S TENANT INTERIOR PARTITION. SEE DETAIL 5/TI-1. NEW B/S TENANT INTERIOR PARTIAL HEIGHT PARTITION @ 46" AFF WITH WOOD CAP TO MATCH B/S WOOD DOORS. SEE DETAIL 8/TI-1. ALIGN. CONSTRUCTION NOTES 1. MAINTAIN A CLEAR PATH OF TRAVEL AT ALL TIMES DURING CONSTRUCTION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & THE BUILDING OWNER / MANAGEMENT AND TENANT. 3. INSTALL DOUBLE STUDS AT DOOR JAMBS AND HEADERS. 4. PROVIDE FIBER GLASS REINFORCED WATER RESISTANT GYPSUM BOARD IN AREAS SUSCEPTIBLE TO MOISTURE. 5. DIMENSIONS ARE FINISH SURFACE TO FINISH SURFACE, U.N.O. 6. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS TO THE ARCHITECT. CONSTRUCTION KEYNOTES EXISTING PARTITION TO BE UPDATED TO STANDARD SOUND PARTITION: SEE DETAIL 6/TI-1. 20 EXISTING DOOR TO RECEIVE NEW EMERGENCY EXIT HARDWARE WITH NO ENTRY IN TO SUITE FROM STAIRWELL. 0 COORDINATE WITH TENANT FOR RELOCATION OF STORAGE SHELVING IN THIS ROOM. 20' 30' NORTH DOOR SCHEDULE (1) 6", UNLESS OTHERWISE NOTED NOTES: DOOR NUMBER TYPE OF DOOR A. NEW B/S 3'-0" WIDE X 8'-4" HIGH SC STAIN GRADE WOOD DOOR IN B/S WOOD FRAME TO MATCH DOORS THROUGHOUT TENANT'S EXISTING SUITE. NEW RELITE FRAMES TO MATCH DOOR FRAMES WHERE APPLICABLE. HARDWARE a. B/S LATCHSET. EXISTING DOOR 1. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO BE LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT 15 EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. 2. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR FOLDING DOOR = 5.0 POUNDS (22.2 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. 3. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.5 INCH (12.7 MM) IN HEIGHT. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 0.25 INCH (6.4 MM) AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50 -PERCENT SLOPE). 4. EXIT DOORS MUST REMAIN UNLOCKED AT ALL TIMES IN THE DIRECTION OF EGRESS. PASSAGE EXIT HARDWARE SHALL REQUIRE NO SPECIAL KNOWLEDGE OR ASSISTANCE TO OPEN OR TO ACCESS. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 4 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 17 2013 PERMIT CENTER tM3 F7 FORT DENT 11 6840 FORT DENT WAY TUKWILA, WA 98188 2221 FIFTH WA 9 1 3 1 (206) 441-4449 DRAWN BY: JK CHECKED BY: KF JOB NO.: 00153.149 NO. REVISIONS INDICATED THUS 0 DATE BY PERMIT SET ISSUED FOR REVIEW PERMIT SET 05/15/13 05/16/13 JK JK TENANT: (THIRD. FLOOR) SILA SOLUTIONS EXPANSION SHEET TITLE: (THIRD FLOOR) DEMOLITION PLAN AND CONSTRUCTION PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF TINS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2013. TI -2 OF 5 SILA-CL—PO-03.dwg 11 II as d O O • 0 O Fi 1-7 O I I I I vip LTJ �1 J 329 CEILING LEGEND REFLECTED CEILING PLAN 1/8" = 1'-0" 5' 10' r–� r ----i 1 11 1 L—J L ----J z LI 0(N) EXISTING CEILING GRID AND TILES TO REMAIN. EXISTING 2'X2' AND 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO REMAIN. EXISTING 2'X2' AND 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY. EXISTING 2'X2' AND 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE REMOVED/RELOCATED. NEW OR RELOCATED BIS 2'X2' AND 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES. NEW OR RELOCATED BIS 2'X2' AND 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY. B/S RECESSED FLUORESCENT DOWNLIGHT. (N = NEW) BIS ILLUMINATED EXIT SIGN (DIRECTIONAL WHERE SHOWN). (N = NEW) BIS LIGHT SWITCH. (N = NEW) LIGHTING CALCULATION EXISTING CEILING GRID, TILE AND FIXTURES TO REMAIN. EXISTING LIGHTING LAYOUT USES 48 FIXTURES. THE NEW LAYOUT RELOCATES 21 OF THE EXISTING FIXTURES. 21/48 x 100 = 43.75% WHICH IS LESS THAN THE 60% ALLOWABLE CHANGE PER 2009 SEC LIGHTING ALTERATION EXCEPTION 1132.3. EXISTING WATTAGE STAYS THE SAME. 20' 30' CEILING NOTES NORTH 1. CHECK FOR CONFLICTS BEFORE INSTALLING OR RELOCATING LIGHT FIXTURES. NOTIFY MSA OF ANY CONFLICT(S). 2. REPLACE DAMAGED CEILING TILES AND GRID AS NECESSARY TO BRING CEILING TO "LIKE NEW" CONDITION. 3. MAINTAIN EXISTING ONE FOOTCANDLE PER SQUARE FOOT AT EGRESS PATHWAY LIGHTING. 4. MAINTAIN 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF ANY V.A.V. BOXES. 5. DAYLIGHT ZONE CONTROL: DAY LIGHTING AS DEFINED BY CODE SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS PER SECTION 1513.3 OF THE WASHINGTON STATE ENERGY CODE. 6. FIRE SPRINKLERS BY OTHERS UNDER DEFERRED SUBMITTALS. 7. COMMISSIONING REQUIREMENTS: TEST LIGHTING CONTROLS TO ENSURE THAT THE SYSTEMS COMPLY WITH CODES. PROVIDE A WRITTEN REPORT OF TEST PROCEDURES AND RESULTS TO THE OWNER. SWEEP CONTROLLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS REQUIRED. 8. EXIT SIGNS ARE INDICATED ON THE REFLECTED CEILING PLAN. THEIR PLACEMENT IS BASED UPON EXISTING CONDITION SURVEY. FINAL NUMBER OF SIGNS, THEIR PLACEMENT AND ARROW DIRECTIONS SHALL BE FIELD VERIFIED WITH THE BUILDING OFFICIAL, CONTRACTOR AND ARCHITECT. 9. IN EXISTING LOBBY AREA (SEE BELOW), REPLACE EXISTING RECESSED CAN LIGHT FIXTURES WITH CEILING MOUNTED FIXTURES THAT DISPERSE FOOTCANDLES MORE EVENLY BUT MAINTAIN EXISTING WATTAGE. UPDATE PENDANT FIXTURES OVER RECEPTION AREA. 334 1 335 �- 3361 1 337 1- 1 338 1- 1 339 1- 332 DECK 1= 330 _1. 329 333 +44 AFF ,..../ (4) 1; (4) 331 341 (1) +44 AFF (1) +60 AFF TI +44 AFF FIRE HOSE 340 ELEC./COMMUNICATION PLAN 1/8" =1-0" ELEC / COMMUNICATIONS LEGEND 0 5' 10' 20' 30' ' I NORTH a NEW BIS WALL MOUNTED DUPLEX ELECTRICAL OUTLET. {� (T) NEW BIS WALL MOUNTED DEDICATED 120V 20A DUPLEX ELECTRICAL OUTLET. (T = TIMER) 2. ROUGH IN ALL DATA AND COMMUNICATION LINES - MUD RING WITH PULL STRING, U.N.O. Id NEW BIS WALL MOUNTED COMBINATION VOICE/DATA OUTLET. ELEC. / COMMUNICATION NOTES 1. ALL ELECTRICAL OUTLETS TO BE MOUNTED AT 15" A.F.F. (AT BASE OF OUTLET) PER W.S.B.C. REQUIREMENTS U.N.O. ® NEW CORE DRILL. (POWER, VOICE & DATA REQUIREMENTS PER PLAN, # =NUMBER OF WORKSTATIONS SERVED) 3. PROVIDE NEW COVER PLATES AND RECEPTACLES AS NEEDED TO MATCH BUILDING STANDARD. 4. MAINTAIN EXISTING ELECTRICAL OUTLETS UNLESS LOCATION CONFLICTS WITH NEW CONSTRUCTION. 5. THE CONTRACTOR SHALL COORDINATE ELECTRICAL, LIGHTING, CASEWORK AND FURNITURE. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 242013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 172013 PERMIT CENTER FORT DENT 11 6840 FORT DENT WAY TUKWILA, WA 98188 • 2221 FIFTH 'ITE„ $ x^....:I.IE WA. 96:121 (206) 441.ra 1449' DRAWN BY: JK CHECKED BY: KF JOB NO.: 00153.149 NO. REVISIONS INDICATED THUS 0 DATE PERMIT SET ISSUED FOR REVIEW 05/15/13 PERMIT SET 05/16/13 BY JK JK TENANT: (THIRD FLOOR) SILA SOLUTIONS EXPANSION SHEET TITLE: (THIRD FLOOR) REFLECTED CEILING AND ELEC./COMMUNICATION PLANS REPRODUCTION, ALTERATION OR PUBLICATION OF 1115 DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLA11ON OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2013. TI -3 OF 5 SILA—FN-03.dwg 334 329 335 336 I- 337 1- EXISTING FLOORING TO STAY 11 LL FINISH NOTES 1. ALL WALLS TO RECEIVE W THROUGHOUT EXPANSION AREA TO MATCH GENERAL PAINT IN EXISTING TENANT SUITE , U.N.O. 2. ALL ROOMS THROUGHOUT EXPANSION AREA TO RECEIVE TO MATCH EXISTING TENANT SUITE, U.N.O. CPT -1 3. BASE U TO BE U ED THROUGHOUT EXPANSION AREA TO MATCH BASE IN EXIST! G TENANT SUITE, U.N.O. 4. PROVIDE (3) SAMPLES OF EVERY FINISH ITEM TO MSA FOR APPROVAL PRIOR TO INSTALLATION. 5. PROVIDE JOHNSONITE "T -MOLDING #CD -XX" IN COLOR 47 BROWN (TO MATCH B-1) AT ALL CARPET TO VCT FLOORING TRANSITIONS. FINISH KEYNOTES 0 CONTRACTOR TO REMOVE EXISTING TENANT SIGNAGE AT RECEPTION AREA TOIALLOW FOR NEW ACCENT PAINT AT EXISTING PARTITION.' CONTRACTOR TO INSTALL SIGNAGE AT SAME LOCATION AFTER PAINTING IS COMPLETE COORDINATE WITH TENANT. FINISH SCHEDULE . SYMBOLINO. DESCRIPTION MANUFACTURER STYLE COLOR / FINISH SIZE NOTES GENERAL CARPET BIGELOW BT284 DATUM MODULAR 7728 CHERT 24" X 24" TILE INSTALLATION: MONOLITHIC PROVIDE SAMPLE SUBMITTAL CPT -1 VINYL COMPOSITE TILE ARMSTRONG STANDARD TEXTURE IMPERIAL EXCELON 51839 FORTRESSINSTALL WHITE 12" X 12" TILE AND SEAL PER MANUFACTURER'S INSTRUCTIONS VCT -1 GENERAL PAINT BENJAMIN MOORE EGGSHELL FINISH HC -26 MONROE BISQUE NA PROVIDE MIN. (3) DRAW DOWNS 0 ACCENT PAINT BENJAMIN MOORE EGGSHELL FINISH GREEN (TBD) NA PROVIDE MIN. (3) DRAW DOWNS 0 ACCENT PAINT BENJAMIN MOORE EGGSHELL FINISH RED (TBD) NA PROVIDE MIN. (3) DRAW DOWNS RUBBER BASE JOHNSONITE COVED 47 BROWN 4.5" NA up CD PLASTIC LAMINATE WILSONART NA TBD NA PROVIDE SAMPLE SUBMITTAL PL -2 PLASTIC LAMINATE WILSONART NA TBD NA PROVIDE SAMPLE SUBMITTAL 11 11 11 11 H 11 11 11 11 u / MN 1 FINISH PLAN 1/8" = 11-0" 0 5' 10' REVIEWED 0 CODE COMPLIANCE APPROVED MAY 2 4 2013 City of Tukwila BUILDING DIVISION 20' 30' NORTH FORT DENT 11 6840 FORT DENT WAY TUKWILA, WA 98188 2221 FIFTH ATENUE, SEAT 91.!: 1 3. (206 4414449 DRAWN BY: JK CHECKED BY: KF JOB NO.: 00153.149 NO. REVISIONS INDICATED THUS A DATE BY PERMIT SET ISSUED FOR REVIEW 05/15/13 JK PERMIT SET 05/16/13 JK TENANT: RECEIVED CITY OF TUKWILA MAY 1 7 2013 PERMIT CENTER tal SHEET TITLE: (THIRD FLOOR) SILA SOLUTIONS EXPANSION (THIRD FLOOR) FINISH PLAN AND FINISH SCHEDULE REPRODUCTION, ALTERATION OR PUBLICATION OF TINS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2013. TI -4 OF 5 FORT DENT 11 SILA-EL-03.dwg B/S PLAM COUNTERTOP 2 /, OPEN ' V.I.F. 36" MAX. tool L 12 60" CLEAR SPACE MIN. FOR COPIER +15" A.F.F. 36" MAX. +15" A.F.F. 0 SUPPORT BRACKETS TYP. PROVIDE MINIMUM FURRING ALONG THIS WALL FACE TO ALLOW SPACE FOR NEW MEP CONDUITS. LINE OF STAIRWELL BEHIND WALL BIS UPPER CABINET WITH DOOR AND (1) ADJUSTABLE SHELF. B/S UPPER CABINET WITH DOOR AND (2) ADJUSTABLE SHELVES. SHELF FOR TENANT PROVIDED MICROWAVE OVEN. RELOCATED SOLID SURFACE COUNTER TOP AND BACKSPLASH. B/S PLAM LOWER CABINETS WITH DOORS, A DRAWER AND AN ADJUSTABLE SHELF, TYP. • +60" A.F.F. +44" A.F.F. O O • • r (2) EQ. 1 +15" 36" CLR. FOR REF. NOTE: 1. PROVIDE FINISHED ENDS ON ALL EXPOSED SURFACES, TYP. MIN. DIM.m 12" (INSIDE CLEAR)or v co 0 0 0 0 0 0 (2) B/S CONCEALED HINGES PER DOOR. 1/4" PLYWOOD BACKING WITH MELAMINE FINISH. 3/4" PLYWOOD ADJUSTABLE SHELF WITH FINISH MELAMINE FINISH. MELAMINE INTERIOR. CABINET DOORS. P -LAM ' U FINISH ON EXPOSED FACE WITH MATCHING B/S EDGE BANDING AND MELAMINE FINISH ON INTERIOR FACE. -ADA-COMPLIANT CASEWORK HARDWARE. (RELOCATED EXISTING DOOR PULLS FROM DEMOLITION) MIN. DIM. ,r ' 24" (INSIDE -CLEAR) PER ELEVATION 0 0 0 MEM OPEN OFFICE CASEWORK 3/8" =1'-0" KITCHENETTE CASEWORK 3/8" = 1 J -OJT UPPER CABINET SECTION 1-1/2" =1'-0" UPPER CABINET SECTION (2) BIS CONCEALED HINGES PER DOOR. 1/4" PLYWOOD BACKING WITH MELAMINE FINISH. 3/4" PLYWOOD ADJUSTABLE SHELF WITH FINISH MELAMINE FINISH. MELAMINE INTERIOR. CABINET DOORS. P -LAM �7 FINISH ON EXPOSED FACE WITH MATCHING B/S EDGE BANDING AND MELAMINE FINISH ON INTERIOR FACE. ADA -COMPLIANT CASEWORK HARDWARE. (RELOCATED EXISTING DOOR PULLS FROM DEMOLITION) 1-1/2" =1'-0 MIN. DIM: 12" (INSIDE CLEAR) N 0 1/4" PLYWOOD BACKING WITH MELAMINE FINISH. 0 0 0 0 0 18" MELAMINE INTERIOR. 3/4" PLYWOOD ADJUSTABLE SHELF WITH MELAMINE FINISH. SHELF SUPPORT, TYP. CABINET DOORS. P -LAM ` ` ` FINISH ON EXPOSED FACE WITH MATCHING BIS EDGE BANDING AND MELAMINE FINISH ON INTERIOR FACE. ANSI -COMPLIANT CASEWORK HARDWARE. (RELOCATED EXISTING DOOR PULLS FROM DEMOLITION) (2) BIS CONCEALED HINGES PER DOOR. PLAM BACK/SIDE SPLASH. SPACE FOR MICROWAVE, TYP. 3/4" FIXED PLAM rL-L ' SHELF WITH MATCHING BIS EDGE BANDING. 3/4" V.I.F. PROVIDE BLOCKING IN WALL AS REQUIRED. 24" SELF -EDGED PLAM WORK COUNTER AND BACKSPLASH. PROVIDE GROMMET. COORDINATE WITH TENANT. PROVIDE SUPPORT BRACKET. (RAKKS OR SIMILAR). SCHEDULED BASE. 25" MELAMINE INTERIOR AS SCHEDULED r RELOCATED SOLID SURFACE COUNTERTOP AND BACKSPLASH. — DRAWER ON (75) POUND FULL- EXTENSION SLIDE. 0 LOWER CABINET SECTION ADA -COMPLIANT CASEWORK HARDWARE, TYP. (RELOCATED EXISTING DOOR PULLS FROM DEMOLITION) (2) CONCEALED HINGES PER DOOR. ADJUSTABLE SHELF WITH MELAMINE FINISH. CABINET DOORS. P-LAMPL-2 FINISH ON EXPOSED FACE WITH MATCHING EDGE BANDING AND MELAMINE FINISH ON INTERIOR FACE. 1/4" PLYWOOD BACKING WITH MELAMINE FINISH. BASE AS SCHEDULED. 1-1/2" =1'-0" NOT USED NA NOT USED NA REVIEWED FOR CODE COMPLIANCE APPROVED MAY 242013 City of Tukwila BUILDING DIVISION FORT DENT 11 6840 FORT DENT WAY TUKWILA, WA 98188 2221 FIFTHN11. ;-A?c,., 961 (206) 441-1449 MICROWAVE SHELF SECTION 1-1/2" =1'-0" COUNTER SECTION 1-1/2" =1'-0" 10 NA NA 11 NA NA 121 NA NA DRAWN BY: JK CHECKED BY: KF JOB NO.: 00153.149 NO. REVISIONS INDICATED THUS A DATE BY PERMIT SET ISSUED FOR REVIEW 05/15/13 JK PERMIT SET 05/16/13 JK 18 NA NA 19 NA NA 20 NA NA 11N NA 2I NA RECEIVED CITY OF TUKWILA MAY 172013 PERMIT CENTER NA TENANT: (THIRD FLOOR) SILA SOLUTIONS EXPANSION SHEET TITLE: (THIRD FLOOR) ENLARGED FLOOR PLAN ELEVATIONS AND SECTIONS REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSll, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2013. TI -5 OF