DEVELOPMENT PERMIT
Parcel No.: 0003000008
Address: 13705 56 AV S TIIKW
Suite No:
Project Name: TERRACE APARTMENTS, BLDG B
Permit Number: D13-182
Issue Date: 06/03/2013
Permit Expires On: 11/30/2013
Owner:
Name: TERRACE APTS
Address: 14240 INTERURBAN AVE S #212 , TUKVVILA WA 98168
Contact Person:
Name: SCOTT PABST
Address: PO BOX 5566 , KENT WA 98064
Contractor:
Name: ROOF TIGHT INC
Address: P 0 BOX 5566 , KENT WA 98064
Contractor License No: ROOFTI*006QA
Lender:
Name:
Address:
Phone: 206-786-0484
Phone: 253-735-2347
Expiration Date: 11/07/2013
DESCRIPTION OF WORK:
REROOF: TEAR OFF EXISTING ROOF DOWN TO 1/2" PLYWOOD SUBSTRATE, INSTALL NEW 3X3 FIBERED CANTS AS
NECESSARY, INSTALL MALARKEY #501 MODIFIED BASE SHEET, AND INSTALL POLYGLASS POLYFLEX "G" WHITE
GRANULATED APP MODIFIED BITUMEN TORCH APPLIED MEMBRANE.
Value of Construction: $52,300.00 Fees Collected: $1,635.20
Type of Fire Protection: International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0021
Electrical Service Provided by: SEATTLE CITY LIGHT
**continued on next page**
doc: IBC -7/10
D13-182 Printed: 06-03-2013
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non -Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date: 6-3-I)
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the erformance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature:
Print Name: CD4t Ku,r
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
6: Manufacturers installation instructions shall be available on the job site at the time of inspection.
doc: IBC -7/10
D13-182 Printed: 06-03-2013
7: All construction noise to be in complianci Chapter 8.22 of the City of Tukwila Municiode. A copy can be
obtained at City Hall m the office of the City Clerk.
8: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate
shall be provided to the building inspector.
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
10: ***FIRE DEPARTMENT CONDITIONS***
11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
12: Application of roof coverings with the use of an open -flame devices requires a separate permit from the Tukwila Fire
Department located at 444 Andover Park East, Tukwila, Washington, 98188; telephone - (206)575-4407. There shall be not
less than one multi-purpose portable fire extinguisher with a minimum 2-A 20-B:C rating and a charged water line (hose)
on the roof being covered or repaired. (IFC 105.6.24, 1417.3)
13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and
#2328)
14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
15: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575-4407.
doc: IBC -7/10
D13-182 Printed: 06-03-2013
CITY OF TUK6A
Community Develop1111,1 Department
Public Works Department
Pernut Center '
6300 Southcemer Blvd , Suite 100
Tukwila, WA 9818
http://www.TukwilaWA.eov
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SIT ' LOCATION
45 -
Site Address:J311i 1 50-":' Ave, 5. -- Btd9. 13''
Tenant Name: The Terrace Aparkmtnf5
King Co Assessor's Tax No.:
Suite Number:
New Tenant:
PROPERTY OWNER
Name: The T.errac+c. Apar te-A4-S
Address: 13Z o S 5-G° Avt, . 5.
City: Tvktvi(4 State: vm Zip: °wIca
CONTACT PERSON — person receiving all project
communication
Name: 5 Cot Pauli' - Roof Tt 31.1i-
Address: PO (30x SSG(,
City: KGn+ State: VJik Zip: cigm
Phone: 2o&-7$6-0�($y Fax:
Email: 0000-1- ten -t+@ q mai 1 , corn
lnG
GENERAL CONTRACTOR. INFORMATION
Company Name: n
1` 00'F Tl q 1l'1'� rn C
.
Address: P,o1 gox SSG(,
I A
City: Ktvt f_ State: w A
Zip: Crgay
Phone: ZO(, -1 17(-0 tail Fax:
Contr Reg No.: Reoprz if 00,0,A Exp Date:
Tukwila Business License No.:
H \Apphcations\Forms-Applications On Line '2012 Apphcavons1Permit Application Revised - 2-7-12 docx
Revised February 2012
bh
Floor:
El Yes .. No
ARCHITECT OF RECORD
Name:
property`
5elC-tv14e. p6,1,„Address:
Company Name:
I A
City:
State:
Architect Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
ENGINEER.OF?RECORD
Name:
property`
5elC-tv14e. p6,1,„Address:
Company Name:
N IA
City:
State:
Engineer Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
gr"eater,pef W 19 27 095 ''''
Name:
property`
5elC-tv14e. p6,1,„Address:
City:
State:
Zip:
Page 1 of4
IrllUILAM IN( 1'ERIVl11411NF'ORMA1 2U6-431-3670
Il'
Valuation of Project (contractor's bide): $ 52 13 00 Existin uilding Valuation: $
Describe the scope of work (please provide detailed information): De -f&; (ea 5.op e o F Iry or (- a, -q,aveA,
-Cor new roo-r liAg .
Will there be new rack storage? ❑ ....Yes
❑ ..No If yes, a separate permit and plan submittal will be required.
Provide All Btiilding Areas in Scfnare Footage Belory
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater'than 18 -inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal ownerlives in one of the dwellings as, his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers , ❑ - Automatic Fire Alarm
❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible dr hazardous materials in the building? '❑ 'Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8-1/2" .x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H.Wpphcattons\Forms-Applications On Line%2012 Apphcations'Permrc Application Revised - 2-7-12 docx
Revised February 2012
bh
Page 2 of 4
Existing
Interior Remodel
Aiiditiori to
MS '>,
Existing
Structure
New
Type of
Construction per
113C
Type of;.
Occupancy%per
IBC
Is' Floor
2rd Floor
3rd Floor
Floors thru
Basement
Accessory Structure*
'
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater'than 18 -inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal ownerlives in one of the dwellings as, his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers , ❑ - Automatic Fire Alarm
❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible dr hazardous materials in the building? '❑ 'Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8-1/2" .x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H.Wpphcattons\Forms-Applications On Line%2012 Apphcations'Permrc Application Revised - 2-7-12 docx
Revised February 2012
bh
Page 2 of 4
PERMITAPPLICATION`NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN,4t OR pUTHO�I;iED AGENT:
Signature: ��//—
Print Name: j C 0 it 0. V 5 '�
RDO4 T9ki-
Mailing Address: PO DD x 55-47(,
H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx
Revised: February 2012
bh
Date: Sfzz1
Day Telephone: 206 D y g y
Kevvr WA- ci$o6 Li
City State Zip
Page 4 of 4
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.gov
RECEIPT
ParcelNo.: 0003000008 Permit Number: D13-182
Address: 13745 56 AV S TUKW Status: PENDING
Suite No: Applied Date: 05/22/2013
Applicant: TERRACE APARTMENTS, BLDG B Issue Date:
Receipt No.: R13-01709
Payment Amount: $1,635.20
Initials: WER Payment Date: 05/22/2013 03:12 PM
User ID: 1655 Balance: $0.00
Payee: ROOF TIGGHT
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 1992 1,635.20
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
000.322.100
000.345.830
640.237.114
Total: $1,635.20
988.30
642.40
4.50
Printed• 05-22-2013
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
.D (3 - 8-2_
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 1.4 (206) 431-367
Permit Inspection Request Line (206) 431-2451
Project:
T rtr�Ace
gd: D. A6
Type of Inspection: n,
-p. ,,u .t
JAi a.): ID I
Address:—L,
I3)os
S(,`"AVP
Date Called:
-P.._Dof.St\
Special Instructions:
.‘Requester:
Date Wanted:
-7 —(-/ --! 3
m.
.m
Phone No:
/ 0,Lt --7fly- o444
Approved per applicable codes. nn Corrections required prior to approval.
COMMENTS:
Insptor: Date:
4tdk
REINSPECTIONFEE REQ IRED. rl r to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION (—Al
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
D'3 -E8"2
Project:
(cj/ Ge
kf.Afr.
Type of Inspection:
fLikk0- r'C`(vl
I
Ls,6
Address -`rt.
!:)7OS-
>tntL/'
Date Called:
(i)..)e_f k)n.-iT) 1 cF4-g
,--,
Special Instructions:
Date Wanted:
Le - 2A -_
' a:m.
:Lp.m.
Requester:
Phone No:
Approved per applicable codes. O Corrections required prior to approval.
COMMENTS:
,
0 / A-'
r
fl((
(i)..)e_f k)n.-iT) 1 cF4-g
I
I n s pectotK
Date
n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.,,Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a. copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-361/0
Permit Inspection Request Line (206) 431-2451
Project:
rr4c(
,,.__.
A(4\Ltom,
Type. f Inspection•
d� 6f --3k16
Address-
13?aS
'71
5G:
-JL.
Date Called:
Special Instructions:
`�
Date Wanted:
' l0-(4—(3
m.
Requester:
-7
Ph o -O42a
CG— ErG
Approved per applicable codes. • QCorrections required prior to approval.
COMMENTS:
tri i `-'�
3 4-- .-FrO I� G.��/ ✓ ��
Date (� �3
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite .100. Call to schedule reinspection.
7
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 �, '(206) 431-367
Permit Inspection Request Line (206) 431-2451
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
Proje
j ui t4iv(-
Typ of Inspection:
jig a f- S'C,. elite, n&
Address:
,r
Date Called:
Special Instructions:
6
%j
,.c
Date Wanted:
(4
. a.m.
-(z- —(3 �plmf
Requester:
Phone No:.
' Co
o -v
ElApproved per applicable codes.
DCorrections required prior to approval.
COMMENTS:
19/.4.
K 2.4
'.
Inspector:
Date: l
-(3
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 . (206) 431-367.
Permit Inspection Request Line.(206).431-2451
Project:
Io -
Type o Inspection: sr
��
Address:
f_ t•-�
Date Called:
Special Instructions:
Date Wanted:
Requester:
Phone NoL, (P _-7
6—°4
EjApproved per applicable codes. tl Corrections required prior,to approval.
COMMENTS:
fi
Ifni, Spector:
Date:10,
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to"schedule reinspection.
INSPECTION RECORD
Retain a copy with permit 3'- t'"
INSPECTION NO. PERMIT NO.
/ CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100; Tukwila. WA 98188 E.' (206) 431-367
Permit Inspection Request Line (206) 431-2451 \ -
Project:
i1�'
Ty of Inspection: '
� oOf 3 (- c ' _A6
t Jf vk—ce
Addres 0�•
7" �`
!
Date Called:
Special Instructions:
?A -Vee-Dr-Ce E..
Date Wanted:.
" cam..
(Q .r i 3 p.m.
Requester:
Y.
Pho •1b ,
—^1 gt ...._0.4......41. r
Approved per applicable codes.
ElCorrections required prior to approval.
COMMENTS:
D(-
1
?A -Vee-Dr-Ce E..
1 ki4 ce.
r
Inspector: •
Date
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 South -c, ter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTIO .NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
1 rfJAC6 A PA-717f'c
Type of Inspection:
-2e_g- F.
Address:_
rt.
Date Called:
Special Instructions:
(2- fy l. %Requester:
Date Wanted:
v r r ! p m.
Phone "N�o:6-
1 e(.. .- 0 j ;..,4
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
,
J
A
'. Al
1\ Sr- L,: M
AAJWT-kPP' P;
StrJ
M (14 t
.i- c i' Qe 1 ? trei
..-^.
A
r
Inspectdr�'
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date:l
fiATkItyr1 nrM0.1kai4P&' IF?r
Owner's Name: The Terrace Apartments
Owner's Address: 13705 56th Ave. S., Tukwila, WA 98168
Building Name' Tihe Tierrace Apts. -Bldg. "B"
Building Address: 13745 56th Ave S., Tukwila, WA 98168
Roofing Contractor Name: Roof Tight, Inc.
Roofing Contractor Address: P. O. Box 5566, Kent, WA 98064
Roofing Contractor Phone: 253-735-2347
Polyglass Product(s) Used: Polyflex G White
Project Size: 13,500 Square Feet
12 Year
LABOR AND MATERIAL WARRANTY
No Dollar Limit
LM 2013-12YR-105
14'2-
RECEIVED
CITY OF TUKWILA
JUL 2 2 2013
PERMIT CENTER
Polyglass Registered Contractor #: 1646
Roofing Specification Used: 200 -W -APP -TOR
Completion Date: July 15, 2013
TERMS AND CONDITIONS:
Definitions: "Polyglass' shall mean Polyglass° U.S.A., Inc. 1111 W. Newport Center Drive; Deerfield Beach, FL 33442. "Owner" shall mean the original
party listed above as Owner's Name whose building the Polyglass roof membrane product is installed.
Polyglass warrants; the Polyglass' membrane to be free from manufacturing defects which affects the ability of the product to perform in a watertight manner
(herein considered defective) for the period of Twelve (12) years from the date of onginal installation of the roofing membrane for aii Mineral Surfaced and Coated
membranes as approved by Polyglass. This warranty is for the sole benefit of Owner described above ("Owner) and is not transferrable or assignable.
Should Polyglass' membrane be deemed defective by Polyglass, as described above, Polyglass shall exercise the option to repair or replace such defective
materials, including any associated labor to perform these tasks without monetary limitation; excluding all instaliation related labor costs associated to flashings,
metal work, or other materials not supplied or furnished by Polyglass. Any such repair or replacement to remedy leakage shall be owner's SOLE AND
EXCLUSIVE REMEDY against Polyglass.
Polyglass shall have no obligation based upon the following exclusions under this warranty:
1) Damage by natural disasters, including but not limited to lightning, hall, gale force or other strong winds exceeding 8 on the Beaufort Scale,
floods, hurricanes, tomadoes, wind launched debris, earthquakes or similar acts of god or natural causes;
2) Damage by willful or negligent acts, fire, vandalism, or other misuse;
3) Damage by use of materials not fumished by Polyglass;
4) Owner or lessee fails to use reasonable care in maintaining and repairing the Polyglass membrane or other required components of the roofing
system.
5) Damage by structural failure, including, without limitation, settling or shifting o1 the building, or movement, cracking, or deflection o1 the roof deck,
roof substrate, roof insulation, building design or construction, inadequate attic ventilation;
6) Damage by any chemical condition not disclosed to Polyglass, or traffic or storage of matenals or infiltration of condensation or moisture in,
through or around the walls, coping, building structure of the underlying or surrounding areas;
7) Alterations or repairs made on or through the roof or objects (including, without limitation, machines, structures, fixtures, or utilities) are placed on
the roof without prior written authorization of Polyglass;
8) Metal work or other materials not fumished by Polyglass and used in the roofing system resulting in leaks;
9) Omissions or Negligence in the application of materials as determined in Polyglass' sole judgment;
10) Failure to utilize Polyglass' latest instructions and recommendations as to installation procedures;
11) Damage resulting from lack of positive, proper or adequate drainage;
12) Loss in part or in whole of granule or other surfacing;
13) Damage or injury arising in any way from an actual or alleged discharge or release of any pollutant or waste, environmental or airbome
contaminates;
14) Damage or injury arising in any way from testing/sampling of underlayment, design and consulting errors or omissions.
In addition to items 1-14 above, owner agrees that Polyglass shall have no responsibility whatsoever for bodily injury to any person or damage to the
structure or its contents directly or indirectly arising out of any defects in its roof membrane or any other consequential or incidental damages or attorneys fees.
Polyglass' sole responsibility is the repair or replacement of defective membrane that is directly related to leakage. This warranty does not include the cost of
removal of existing, or the cost of labor to repair or replace the defective membrane and/or roofing covering/system installed to the Polyglass membrane.
Claim Procedure:
Polyglass shall have no obligation under this warranty unless Owner shall have promptly notified Polyglass in writing to Polyglass by registered or certified
mail. Direct all claims to Polyglass, U.S.A., Inc. 1111 W. Newport Center Drive, Deerfield Beach, Florida 33442, ATTN: Warranty Department. Any claim shall
provide a copy of the warranty and detailed information of the leakage and alleged defect. Polyglass must receive such notice within ten (10) days after discovery
of the claimed defect.
Owner shall provide Polyglass, and its agents and employees, free and reasonable access to the roof during regular business hours during the term of the
warranty. Owner shall be responsible for all costs related to safe and reasonable access to investigate claim.
Polyglass' good -faith determination of the source of leakage, damage, or alleged defect to the roof shall be exclusive and binding to owner.
Polyglass' failure at any time to enforce any of the tents and conditions of this warranty shall not be construed as a waiver of such provisions.
Polyglass reserves the right to discontinue or modify any of as products and shall not be liable to Owner as a result of any such discontinuance or
modification.
THIS WARRANTY SUPERCEDES AND IS IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED, INCLUDING, WITHOUT
LIMITATION, WARRANTIES OF MERCHANTABLILITY AND FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY SHALL BE OWNER'S EXCLUSIVE
REMEDY AGAINST POLYGLASS OR ITS AFFILIATES, AND NEITHER POLYGLASS NOR ITS AFFILIATES SHALL BE LIABLE FOR ANY CONSEQUENTIAL
OR INCINDENTAL DAMAGES. POLYGLASS' AGENTS HAVE NO AUTHORITY TO GIVE WARRANTIES BEYOND THOSE PROVIDED IN THS
WARRANTY.ALL RIGHTS AND DUTIES ARISING UNDER THIS WARRANTY SHALL BE GOVERNED BY FLORIDA LAW.
Warranty presented and determined as incomplete or inaccurate shall be considered null and void.
Jun.200
Building Owner Roof Maintenance Warranty Guidelines
MAINTENANCE AND CARE FOR YOUR POLYGLASS ROOF MEMBRANE
To avoid interruption and/or cancellation of your warranty coverage, the following Maintenance
Program is a requirement.
There are various items associated with your roof system that are NOT covered under the warranty. The
manufacturer's warranty is not a maintenance program or agreement and not provided for within the warranty.
Some issues may have a direct impact on the performance, life cycle and watertight integrity of the installed
roofing membrane/system. It is the responsibility of the Owner to regularly maintain the roof. As the Owner, a file
of records should be maintained related to all roof and roof -top associated activities. Such file should contain the
original warranty, invoices related to the original roof installation, repair invoices, a log of any roof inspections and
any roof -top activities such as service to roof top mechanical units. POLYGLASS® strongly recommends the
Owner institute a roof log for all parties accessing the roof, regardless of who or the purpose, that they are
required to sign. This protects you, the owner, from 1) unwanted roof traffic and 2) any damage caused can, many
times, be traced back to the responsible party.
Industry related organizations and POLYGLASS® recommend that the roof should have a visual
inspection at a minimum rate of two (2) times per year by a qualified professional. Many Polyglass Registered
Contractors offer this service for a nominal fee. Inspections are generally recommended in the spring and fall. It
is a good practice to have the roof inspected after severe weather conditions such as: hail, strong winds,
hurricanes, blizzards, ice storms, etc. Proper precautions should always be followed during inspections to
prevent against trip/fall accidents.
Guidelines For Roof Inspection & Generalized Remedial Repairs
1. READ YOUR WARRANTY CAREFULLY BEFORE EXECUTING ANY ROOF -TOP WORK OR FILING
OF A CLAIM. Understand in detail what is covered by the warranty, its Terms and Conditions and what
may be required to avoid adversely affecting the warranty. This is applicable to products used for low -
slope roof conditions (membranes), steep -slope roof conditions (underlayments) and fluid -applied
systems (Elastomeric products).
2. Remove all debris, such as but not limited to, leaves, twigs, branches, dirt, rocks, bottles, trash, etc., that
has accumulated and may block water outlets.
3. Clean gutters, downspouts, roof drains and scuppers. Make sure water freely flows from the roof. No
standing water should remain on the roof surface within 48 hours after the last precipitation.
4. Examine all metal flashing areas for rusting or damage that may have been caused by traffic, wind, hail,
snow, ice, etc. All damaged, loose, or poorly sealed materials must be repaired by a POLYGLASS®
Registered Contractor or other qualified contractor authorized by POLYGLASS®.
5. All exposed mastics and sealants regardless of purpose or function, are required maintenance items to
be remediated by the Owner, including pitch pan and metal flashing sealants. The manufacturer's
warranty does not provide for care and maintenance of these.
6. Examine all adjacent areas to the roof, parapet walls and adjoining structures. Damage to items such as
masonry, failing mortar joints, loose or missing sealants, loose stone stone/tile, loose and improperly
sealed counterflashing, etc. often causes leaks that are inadvertently blamed on the roofing system and
not provided for by the manufacturer's warranty. Not only does this cost the roofing manufacturer time in
the investigation of problems not associated with the roofing membrane or protective coating materials; it
costs the Owner time and money. Many roofing manufacturers, including POLYGLASS®, reserve the
right to back -charge an Owner for the time and out -of -pockets costs spent to investigate non -roof or non -
warranted related problems. These items need to be repaired by the properly trained personnel to avoid
any unnecessary charges or voiding of warranty coverage. Unauthorized repairs to the roof will void
warranty coverages.
7. Loss of granules from mineral surface membranes is typical and not a manufacturing defect. In cases of
granule loss that becomes more noticeable, additional surfacing should be applied as directed by
POLYGLASS®.
8. Protective elastomeric coating systems will oxidize and weather, losing overall dry film thickness, this is
normal, to be expected and in no way a defect in the material. Manufacturer's warranties that include or
for elastomeric coating products require recoating at an interval stated on the warrant to maintain
coverage. Lack of required re -coating and maintenance of fluid -applied systems will void the warranty.
9. When repairing items to the roofing membrane or protective coating system, associated items, or building
structure, be sure to use precaution and properly protect the roofing surface from unnecessary damage.
10. Examine roof top equipment, air condition units, condensers, exhaust fans, antennas and other roof top
items for damage. Check for leaking oil, damaged flashings or loose parts/equipment that could cause
puncture damage to the roofing membrane or any protective coatings. All units shall be checked to
assure they are sound, watertight and not be displaced by wind events.
11. Check the building for excessive movement or settlement. Improper placement or omission of or needed
expansion joints could cause splits or stress in the roofing material/system, drastically reducing the life
cycle of the roofing system and may void warranty.
12. All work directly or indirectly related to the roofing system where the roofing material needs to be
repaired, i.e. new curbs, units, exhaust fans, antenna installation, repairs, etc., must be accomplished by
a current POLYGLASS® Registered Contractor. Failure of the Owner to utilize an authorized applicator
will result in immediate termination of the warranty without prior notification.
Conditions beyond those noted herein above should be provided to POLYGLASS® in writing within 15 days of
discovery for recommendations.
April 2, 2013
Roof Tight Inc.
P.O. Box 5566
Kent, WA 98064
Re: The Terrace Apartments at: 13705 56th Ave S
Tukwila, WA 98168
To Whom It May Concern:
A limited inspection of the above property was performed on March 30 and April 1, by Dave
Pioli, P.E. For your interest, a copy of his resume is attached.
INTRODUCTION
The purpose of this inspection and report is to evaluate the roof drainage and notching of the
framing.
This scope of this inspection does not include a comprehensive evaluation for code compliance,
governmental regulation compliance, fire safety or hazardous materials in or around this
building. It does not include an inspection of heating, cooling, plumbing and electrical systems
or repair designs.
Terms used in this report to describe the condition of observable components and systems are
listed and defined below. It should be noted that a term applied to an overall system does not
preclude that a part or a section of the system or component may be in different condition:
The following definitions are used in this report:
Average Typical for this part of the country and for buildings of similar age and type.
Excellent Component is in new condition.
Good Component is sound and performing its function, although it may show signs of
normal wear and tear. Maintenance may be required.
Fair Component falls into one or more of the following:
• Repairs or workmanship not in compliance with commonly accepted practice.
• Repair is required.
• Approaching end of expected service life.
Poor Component has failed or cannot be relied upon. Repair or replacement is
required.
This report is an opinion about the condition of this portion of the building. It is based on
evidence available during a diligent inspection of all reasonably accessible areas. No surface
materials were removed, no destructive testing undertaken, nor furnishings moved. This report is
not an exhaustive technical evaluation. Such an evaluation would cost many times more.
This inspection report is limited to observations made from visual evidence. No destructive or
invasive testing was performed. The report is not to be considered a guarantee of condition and
no warranty is implied. As Professional Engineers, it is our responsibility to evaluate available
evidence relevant to the purpose of this inspection. We are not, however, responsible for
conditions that could not be seen or were not within the scope of our service at the time of the
inspection.
DESCRIPTION
This house is a multi -family, 3/4 -story apartment buildings with a low slope roof surfacing.
OBSERVATIONS
These buildings (A, B, C, D) are in process of undergoing roof resurfacing. The existing older
roof surface is being removed and replaced with a torchdown roof surfacing.
The item of interest is the notching of a few of the roof framing members to provide a drainage
path on the roof surface. These framing members are inside a box vent. Refer to attached
photos. This box vent is equipped with turbine fans that provide some air flow. .
In order for this drainage to work, it requires notching the top of one of the framing members
some 11/ -inch. Currently, building A is in process of re -roofing. Building A is the subject of the
photos. However, the other buildings B, C and D are identical and similar work is proposed. •
CONCLUSIONS. AND RECOMMENDATIONS
This notching of the framing for the drainage does not have an impact on the structural condition
of the roof framing and is acceptable on all four buildings.
Many things have been discussed in this report. However, we realize that there may still be other
things of interest to you that have not been discussed. Therefore, we encourage you to call with
any additional questions you may have at our office: Criterium-Pioli Engineers, 425/486.4000.
This report has been prepared in strict confidence with you as our client. No reproduction or re-
use is permitted without express written consent. This report is the complete response to the •
inspection and should be read in full. It supersedes discussions during the inspection.
Thank you for the opportunity to be of assistance.
Sicerely,
(V..../EATtr
Dave PioliP.E.
Principal
Attachment: Photos
Page 2
04/02/13
PROFESSIONAL QUALIFICATIONS AND EXPERIENCE
DAVE PIOLI, P.E.
Area of Expertise
Dave Pioli, P.E. is a licensed Professional Engineer in Washington and Oregon. He provides
inspection services and specializes in the area of structural evaluations and environmental issues
for residential and commercial buildings.
Qualifications
Mr. Pioli is the Principal of Criterium—Pioli Engineers, an engineering firm that specializes in
building inspections. He has inspected thousands of residential and commercial buildings in the
greater Seattle area. Evaluations have included structural soundness, Capital Needs
Assessments, Condominium Reserve Studies, design plans of repair, as well as hazardous
materials, slope stability, and safety. Additional projects include Comprehensive Needs
Assessments for multi -family housing, fraternity/sorority houses and funeral homes.
Mr. Pioli also has experience as a residential remodeling contractor.
Prior to his affiliation with Criterium-Pioli Engineers, he was the sole proprietor of
Environmental Engineering where he was responsible for the design of methane gas studies for
construction near abandoned landfills, and preparation of permit and construction drawings for
topsoil manufacturing.
Mr. Pioli was employed with EMCON as a Project Engineer for the design of several solid waste
landfills and hazardous waste projects. He also served as Project Manager for the design and
construction of recycling facilities.
Previously, he was an engineer for Glacier Environmental Services, Inc. He was responsible for
the removal of underground storage tanks and environmental clean up projects.
Education and Professional Affiliation
The Ohio State University, BS in Civil Engineering, 1983
Professional Engineer, State of Washington, 1988
Professional Engineer, State of Oregon, 1988
National Academy of Building Inspection Engineers, Professional Member
Board certified Building Inspection Engineer, NABIE, 2008
Structural Pest Inspector, Washington State Department of Agriculture
Vice Chair, Home Inspectors Licensing Board, State of Washington
Licensed Home Inspector, State of Washington, License #203
Page 3
04/02/13
Description:
Framing member
that has been
notched. Center 2
framing members
have been notched,
visible in photo.
Photo Number
1
Description:
Framing member
that has been
notched. Center 2
framing members
have been notched,
visible in photo.
Photo Number
2
Page 4
04/02/13
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: revisions will require a new plan submittal
and may include additional plan review fees. 1
4
d
<7'4
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
Electrical
Plumbing
Gas Piping
City of Tukwila
EVI_Cs G DIVISION
Tk- TeCr4Ce
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 3 0 2013
K.1
City of
BUILDING
VISION
FILE COPY
Permit No. 1,70110 #-112^
Flan review approval is wed to eras and omissions.
Approval of constnxtion documents does not authorize
til::. oration of any adopted code or ordinance. Receipt
et approved ! Copy"*o3nditions is adallowledged:
Data C I3 i3
By
City Of lbkvvila
BUILDING DIVISION
Dia -1s2
RECEIVED
CITY OF TUKWILA
MAY 2 2 2013
PERMIT CENTER
REV
CODE COMPLIANCE
APPROVED
MAY 302013
City of Tukwila
BUILDING DIVISION
250
skromil
ti
Oft
1
1
C,ve Ct,r165J
RECEIVED
CITY OF TUKWILA
MAY 2 Z 2013
PERMIT CENTER
Frt. ffl by
Proposal Submitted to:
Tecton Corporation
Job Name:
The Terrace Apartments A,B&Carports
Date:
01/03/13
Street Address:
14240 Interurban Ave S #212
Job Description:
Roof Replacement A, B and Carports
Bid #
08-01-13
City, Sate, Zip
Tukwila, WA 98168
Location:
13705 56th Ave S Tukwila, WA
Quantity:
As listed
Attention:
Mike Jansen
Phone: 206-448-4100
Fax 206-448-4777
Source
Rpt.
Scope of Work
1) A "Honey Bucket" portable toilet will be on location for our workers d
project.
REVIEWED FOR
CODE COMPLIANCE
ing APPROVED
MAY 3 0 2013
2) Remove existing cap metal flashings and haul away in preparation for ew.
3) Tearoff and remove all the existing roof coverings down to the '/2" pl
substrate. Set any protruding fasteners and sweep roof clean and dry a
During the removal process, the substrate is to be inspected for structural
soundness. Any extra labor connected with repair work will be charged on a time
($57.50 per hour) and materials basis. Plywood replacement will be billed at
$52.00 per sheet of 1/2" 4'x$' CDX plywood; Plywood replacement billing rates
include labor, materials, hauling and disposal fees.
City of Tukwila
LDING DIVISION
4) Provide and install new 3x3 fibered cants as necessary at all vertical roof -to -wall
and straight curb penetrations and transitions.
5) Mechanically Fasten Malarkey #501 modified base sheet with 2"side laps and
6" end laps directly to the substrate and extend up ail cant strips at least 2"
6) Provide and install Polyglass Polyflerc "G" White Granulated APP Modified
Bitumen torch applied membrane over the roofing area consistent with the
manufacturer's standard specifications. WARRANTY:12-year on Labor and
12 -year on Material according to the manufacturer's written warranty.
7) Prime coat all wall surfaces in preparation for the self adhered base sheet and
torch membrane.
bV?8Z
P.O. Box 5566 • Kent, WA 98064-5566
(425) 917-2020 • (206) 786-4412 • Fax (253) 735-2348
Contractor's License: ROOFTI*006QA
RECEIVED
CITY OF TUKWILA
MAY 2 1 2013
PERMIT CENTER
7•
INC.
8) Install Elastoflex SAV self adhered SBS base sheet over all walls. Mechanically
fasten with simplex roofing nails for extra holding strength to make sure the torch
membrane stays perfectly in place without sagging.
9) Provide and install at the parapet walls and/or similar vertical surfaces, where
required the torch applied flashing membrane consistent with manufacturer's
specifications.
10) Membrane Flash Curbs, roof edges and other roof transitions where required.
This means that the edges will have a double layer at all bends.
11) Provide and install new lead pipe jacks and lead caps before the flashing
according to the manufacturer's specifications.
12) Provide and install white aluminum turbine roof vents. Diameter 12" at throat,
The flanged flat base is to be membrane flashed into the roofing system or box
curb mounted and membrane flashed in according to the job requirements. (44 -
each turbine fans to be installed)
13) Remove existing deck mounted roof vents and save. At vent opening construct a
wood 2x8 curb with a 2x2 cant at the base. Base and membrane flash the new
curbing, then replace the roof vents with new on the raised curbs using screws for
attachment. Note: It is important to make sure that all bath fans and dryer lines
are vented out the roof surface and not into the rafter or attic cavity.
14) All existing down drop scuppers will be removed and discarded. New sheet metal
down drop scuppers will be installed according to the manufacturer's
specifications.
15) Any additional drainage revisions including new drains, adding slop and
downspouts to relieve standing water conditions will be an extra to this contract
on a time & materials basis.
16) Any ventilation improvements required in the rafter cavities will be corrected on a
T & M basis. Whether or not more ventilation is required on this building will be
determined by the condition of the plywood deck when the old roof is removed.
17) Termination bar metal will be installed where required to make a watertight
condition per the manufacturer's warranty specifications.
18) Install new prefinished Brown 24 -gauge galvanized perimeter edge metal.
19) Composition Sloped Sections:
P.O. Box 5566 • Kent, WA 98064-5566
(425) 917-2020 • (206) 786-4412 • Fax (253) 735-2348
Contractor's License: ROOFTI*006QA
20) Tear off and remove the composition layer down to the wood sheathing. Set any
protruding fasteners and sweep roof clean and dry as required. Haul debris away.
21) Install over the entire roof area 1 -layer of 30# ASTM asphalt saturated felt under-
layment. The felt is to be installed shingle fashion starting at the lower edge to of
the roof and lapping over each other 2" on the upper edge and 6" on ends.
22) Provide and install according to the manufacturer's specifications, Pabco Premier
fiberglass shingles UL Class "A" fire rated. Warranty: Limited Lifetime
consistent with the manufacturer's standard form and 10 -year labor by Roof
Tight. Color: Weathered White
23) Install new starter and bleeder strips as per manufacturer's specifications.
24) At ridge, replace the ridge vent with new PVC nail on ridge venting and cover
with ridge material according to the manufacturer's specifications.
25) Install new hip and ridge shingles at all required locations.
26) Install 1 't/2"x 1 '/2" in stretch dimension, pre -painted (baked on enamel), 26 -gauge
Galvanized gable end (rake) metal. Color: Brown
27) Install new gutter edge metal prefinished (baked on enamel), 26 -gauge. Color:
Brown.
28) Contractors during the execution of this contract will at all times operate in a safe
and organized manner keeping all tools, equipment and vehicles in designated
work area. The job site will be swept and kept clean of debris during working
hours and prior to daily work completion.
In consideration for providing all equipment, labor and materials here in the described,
complete in accordance with above specifications, for the contract sum of:
Building "B" $52,300 + extras and sales tax
Carports all 4S $17,460 + sales tax
Building "A" $52,300 + extras and sales tax
Payment Terms:
40% down payment per building
60% upon completion per building
PO. Box 5566 • Kent, WA 98064-5566
(425) 917-2020 • (206) 786-4412 • Fax (253) 735-2348
Contractor's License: ROOFTI*006QA
ts.
PO LYG LASS® G2 BASE � ,�. �� copy
Permit No.
Polyglass G2 Base is a premium, inorganic fiberglass mat reinforced base sheet
which has been saturated and coated with a weathering grade asphalt. The top
surface is then coated with a fine mineral parting agent to prevent sticking in the roll.
PRODUCT DESCRIPTION
Designed as an ideal first roofing ply in SBS/APP modified or Built Up roofin
this wrinkle resistant easy roofing membrane can be installed over a variety
USES
• Specially designed as a base layer in hot mop, cold applied and me
attached applications
FEATURES AND BENEFITS
systems,
strVIEWED FOR
CODE COMPLIAN
APPROVED
hanicallAY 3 0 2013
City of Tukwila
BUILDING DIVISION
PR • ' ' DATA
• Strong, resilient base sheet with exceptional nail holding performance and
puncture resistance
• Wrinkle resistant; will lay flat for easy install
• Consistent thickness on both sides eliminates pinholes preventing asphalt
bleed through
TECHNICAL DESCRIPTION
TEST METHOD
ASTM 4601
PROPERTY
Mass of Desaturated Glass Mat
TYPICAL
VALUE
1 7 lbs/ 100 ft2
ASTM 4601
Surfacing and stabilizer, max %
65
ASTM 4601
Mass of Asphalt Coating
7.0 lbs/ 100 ft2
ASTM 4601, Type 0
Breaking strength @ 77°F (longitudinal and
transverse)
44 Ib ft/in
Copyright (50201 i by Polygl°ss USA-, Inc o".d oll ,;ghts . -'red
Edition Data: 08/11 • Dos# Polyglass G2 Base
RECEIVED
CITY OF TUKWILA
MAY 21 2013
PERMIT CENTER
Coverage (Nominal)
Weight (Approx)
300 sq ft
72 lbs
Roll Size 108' x 36"
Rolls/Pellet
16
APPLICABLE STANDARDS
• ASTM D 4601 Type II
• UL Classified for use in class A, B or C
roofs, as listed in the latest UL "Roofing
Materials and Systems Directory"
•
TDI
:6
PRODUCT WARRANTY
Pelyglass USA, Inc. commercial roofing membranes
can be backed with a manufacturer's warranty for
up to 20 years when used as part of an approved,
multi ply roofing system. Please see your PoIygkass
USA, Inc. Sales or Technical Representative for
specifications and details.
,, TP.'PRuo lNta ;IA.rzr,'ALs AN' :NSULATING SYSTEMS
POLYGLASSiimmiij
G R O U P
SYadie S
1-800-222-9782
www.polyglass.com
;:11.1:ztioquit t--1
.41
hI'OLYGLASS® G2 BASE
0
mAPPLICATION INSTRUCTIONS
Polyglass G2 Base is intended to be used as a base sheet in new or re -roof applications Polyglass G2 Base may be applied
directly to non combustible substrates. Polyglass G2 Base requires the installation of a compatible granulated cap sheet to
complete the roofing system.
• Apply over dean, dry, dust and debris -free substrates. Prime concrete decks prior to application with PG 100
Asphalt Primer.
• When re -roofing, remove all prior roofing materials down to a clean debris -free substrate and properly close -off
all abandoned roof penetrations.
• Concrete or steel decks shall be designed with proper expansion devices.
• Wood decks shall have all joints blocked and properly supported.
• Ensure the fire rating of the assembly over any combustible substrate.
• Ensure the installation of Polyglass G2 Base does not prevent the ventilation of existing construction.
• Do not apply over shingles or any granulated surface.
• While installing Polyglass G2 Base:
1. Start at the low point of the roof.
2. Unroll the material and allow to relax.
3. Position successive rolls providing a minimum 6" end lap and 3" side lap.
• Polyglass G2 Base can be used as a base sheet in flashing applications. Check project details for proper installation requirements.
• Engineered to be used in BUR construction of roofs.
POLYGLASS U.S.A., INC. MANUFACTURING FACILITIES
• Fernley, NV
• Hazleton, PA
• Winter Haven, FL
CORPORATE HEADQUARTERS
Polyglass U.S.A., Inc.
1 1 1 1 West Newport Center Drive
Deerfield Beach, FL 33442
www.polyglass.com
General Line: (888( 410-1375
(954) 233-1330
Customer Service: (800) 222-9782
Technical Service: (866) 802-8017
Questions? technical@polyglass.com
Product Disclaimer. Unless otherwise incorporated into or part of a supplemental manufacturer's warranty, Polyglass warrants its product(s)
against manufacturing defects in its product that directly results in leakage for a period of 2 years.
Refer to material safety data sheet (MSDS) for specific data and handling of our products. All
data furnished refers to standard production ands given in good faith within the applicable
manufacturing and testing tolerances.
Polyglass U.S.A., Inc., reserves the right to improve and change its products at any time with-
out prior notice. Polyglass U.S.A., Inc. cannot be held responsible for the use of its products
under conditions beyond its own control.
For most current product data and warranty information, visit www.polyglass.com
TATERi'E uF1YG MATERIALS LSD INSULATING SYSTEMS
POLYGLASS
MAPEI
GROUP
SY o e�
1-800-222-9782
www.polyglass.com
POLYFLEX® G
PRODUCT DESCRIPTION
PILE COPY
Per(rr
Polyflex G membranes are premium, polyester reinforced APP modified bitumen roofing
membranes specially designed for heat -welded applications. Constructed with premium
Atactic Polypropylene resins, and incorporating superior polyester reinforcing, Polyflex G
provides an exceptionally durable roofing product which is easy to install and will
provide long-term weathering performance.
With a granulated surface (available in several colors) and either a polyolefin
or sand backing, Polyflex G exceeds all minimum ASTM standards for tensile
strength, puncture resistance and flexibility. """'"" " ""
REVIEWED FOR
Polyflex G membranes can also be used as flashing membranes in 3).SOMPLIANCE
specifications, in accordance with recommended installation practic es.
USES
• Heat -welded or cold -applied cap sheet
• Applied directly over an acceptable substrate or as part of a m
• New roofing, re -roofing, re-cover and for flashing details
APPROVED
MAY 3 0 2013
JIti-plynaf Tuk '
BUILDING DIV'srui� T DATA
a- fox)
.FEATURES AND BENEFITS
• Exceptional weathering characteristics
• Puncture and tear resistant
• Low -temp flexibility, exceptional tensile strength and elongation properties
TECHNICAL DESCRIPTION
TEST METHOD
ASTM D5147
PROPERTY
Thickness, typical, mm (mils)
'TYPICAL
VALUE
4.5 (180)
ASTM D5147
Peak Load @ 23-/-2C (73.4+/-3.6F), MD
and XMD, min, kN/m (Ibf/in.)
8.8 (50)
ASTM D5147
Elongation @ 23+/-2C (73.4+/-3.6F), MD
and XMD, rnin-!'ol_ —_
a?
ASTM D5147
Tear Strength @ 23+/-2C (73.4+/-3.6F),
min, N (Ibf)
31 1 (70)
ASTM D5147
Low Temperature Flexibility, max, C (F)
0 (32)
ASTM D5147
Granule Embedment, g
2
AVAILABLE COLORS
Top surface granule protection is available in a variety of colors such as.
Black Buff Chestnut
White Red Blend Pine Green
10/2010
Grey Slate Oak
Heather Blend Weatherwood
Weight
100 sq
110 lbs
Roll Size 32-10" , 39 /s° (10MA l m(
Rolls/Pallet 20
APPLICABLE STANDARDS
• ASTM D 6222 Type I
• Miami Dade Code Compliance
• Factory Mutual Approved
• UL Classified for use in class A, B or C
roofs, as listed in the latest U' "Roofing
Materials and Systems Directory'
• ICC ESR -2018
• TDI
PRODUCT WARRANTY
Unless otherwise incorporated into or port of a
supplemental manufacturer's warranty, Polyglass
warrants its product(s) for a period of 10 years
against manufacturing defects in its product that
directly results in leakage. Warranty coverage
is an annually declining pro -rated warranty.
NA I3i4I.t4f ING i1.ATE3i',L' .i?? II SL LAT.>;; ,YSTEl1a
L
POLYGLASS�
RECEIVED
CITY OF TUKWILA
MAY 2 Z 2013
PERMIT CENTER
MAPEI
G R U U f
Adis vat ee e
1-800-222-9782
www.polyglass.com
PR•D
T •MIT?
POLYFLEX) G
APPLICATION INSTRUCTIONS
Polyflex G is intended to be used as the primary weathering surface in new or re -roof applications. Polyflex G is to be applied
as the outermost layer of a multi -ply roof system over a compatible Polyglass base or inner ply sheet. Polyflex G may be applied
directly to non-combustible substrates.
• Apply over clean, dry, dust and debris -free substrates. Prime concrete decks prior to application with PG 100
Asphalt Primer.
• When re -roofing, remove all prior roofing materials down to a dean debris -free substrate and properly close -off all
abandoned roof penetrations.
• Concrete or steel decks shall be designed with proper expansion devices.
• Wood decks shall have all joints blocked and properly supported_
• Ensure the fire rating of the assembly over any combustible substrate.
• Ensure the installation of Polyflex G does not prevent the ventilation of existing construction.
• Do not apply over shingles or any granulated surface.
• While installing PolyfleX G:
1. Start at the low point of the roof.
2. Unroll the material and allow to relax in the sun for at least 15 minutes.
3. Install with traditional torch roofing techniques ensuring proper heating of the roofing material as not to expose
the reinforcement.
4. Do not heat the substrate.
5. Position successive rolls providing a minimum 6" end lap and 3" side lap. Asphalt bleed out shall be 1 /4" to
3/8" on all seams.
6. Laps shall be rolled with a 6" -wide roller immediately after heat welding.
• Details and Hashing may be installed using Polyflex G with torch applied techniques. Do not use cold adhesives or hot
asphalt. Check project details for proper installation requirements.
MANUFACTURING FACILITIES
• Fernley, NV
• Hazleton, PA
• Winter Hoven, FL
ALL DATA FURNISHED REFERS TO STANDARD PRODUCTION AND 15 GIVEN IN GOOD FAITH WITHIN THE APPLICABLE MANUFACTURING AND TESTING TOLERANCES.
POLYGLASS USA, INC., RESERVES THE RIGHT TO IMPROVE AND CHANGE ITS PRODUCTS AT ANY TIME WITHOUT PRIOR NOTICE. POLYGLASS USA, INC. CANNOT BE HELD
RESPONSIBLE FOR THE USE OF ITS PRODUCTS UNDER CONDITIONS BEYOND ITS OWN CONTROL.
WArERi'1L,GtiNG ;ili.TE2IAI,? AND 11.,EATING �1'd-L1fa
1-800-222-4782
www.polyglass.com
PERMiT Dv
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: D13-182 DATE: 05-22-13
PROJECT NAME: TERRACE APARTMENTS - BLDG B
SITE ADDRESS: 13705 56 AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
pLe Awc 0541'11
Building Division if
Public Works ❑
Fire Prevention
Structural
1
n
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Incomplete ❑
DUE DATE: 05-23-13
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: - LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials:
TUES/THURS ROUTING:
Please Route k Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 06-20-13
Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Documents/routing slip.doc
2-28-02
PLAN REVI W CHECKLIST - (Nonstructural)
By: '4/
Date:
Permit App. 0 I- - (d 2
IBC Edition 09 & State Amend.
Project title: 7 vr1 -c'4p%r p ,i�+
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
Classify the building or portion thereof in accordance with Chapter 3
Determine the type of construction of the building in accordance with Chapter 6.
Determine if the location of building on the site and clearances to property lines and
other buildings on the site plan are in accordance with code provisions.
A, Review for conformity with General building height and area limitations in accordance
with Chapter 5.
Review for conformity with special detailed requirements based on use and
Occupancy.
Review for conformity with Type of Construction requirements of Chapter 6.
Review for conformity with Fire and Smoke protection features of
Chapter 7.
Review for conformity with requirements of interior finishes of Chapter 8.
Review for conformity with requirements for fire protection systems of Chapter 9.
Review for conformity with requirements for means of egress requirements
of Chapter 10
1)c --N Review for conformity with requirements of accessibility in accordance with Chapter
11, and A117.1
Review for conformity with Washington State Energy Code.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
✓ In circle = topic has been reviewed for the application.
X In circle = topic is not relevant to proposed scope of work.
Contractors or Tradespeople P ter Friendly Page
i
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite/Apt.
City
State
Zip
County
Business Type
Parent Company
ROOF TIGHT INC
2537352347
Po Box 5566
Kent
WA
980645566
King
Corporation
UBI No. 601988145
Status Active
License No. ROOFTI'006QA
License Type Construction Contractor
Effective Date 11/1/2000
Expiration Date 11/7/2013
Suspend Date
Specialty 1 General
Specialty 2 Unused
Business Owner Information
Name
Role
Effective Date
Expiration Date
PAUST, SCOTT
01/01/1980
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
3
American Contractors
Indem CO
100141377
11/01/2010
Until Cancelled
$12,000.0010/13/2010
2
CBIC
SD2984
11/01/2001
Until Cancelled
11/01/2010
$12,000.0010/18/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
15
Kinsale
Insurance
Company
0100001668-1
03/03/2012
07/03/2013
$1,000,000.0002/20/2013
14
KINSALE INS CO
00099939
03/03/2011
03/03/2012
$1,000,000.0003/02/2011
13
CENTURY
SURETY CO
CCP640688
03/03/2010
03/03/2011
$1,000,000.0003/02/2010
12
CENTURY
SURETY CO
CCP588263
03/03/2009
03/03/2011
$1,000,000.0003/01/2010
11
CENTURY
SURETY CO
2131604B
03/03/2009
03/03/2010
$1,000,000.0002/27/2009
10
FIRST MERCURY
INS CO
FMWA000073
03/03/2008
03/03/2009
$1,000,000.0003/05/2008
9
FIRST MERCURY
INS CO
FMFL002574
03/03/2007
03/03/2009
$1,000,000.00
02/15/2008
8
BURLINGTON
INS CO
HGL0012240
03/03/2007
03/03/2008
$1,000,000.00
02/28/2007
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
httns.//fnrfress_wa. tnv/1ni/hhin/Print.asnx
06/03/2013