HomeMy WebLinkAboutPermit D13-199 - LYNCH RESIDENCE - TENANT IMPROVEMENTLYNCH RESIDENCE
10710 49 AV S
D13-199
Parcel No.:
Address:
Suite No:
Project Name:
City oikukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
5476800132
1071049AVSTUKW
LYNCH RESIDENCE
•
DEVELOPMENT PERMIT
Permit Number:
Issue Date:
Permit Expires On:
D13-199
06/21/2013
12/18/2013
Owner:
Name:
Address:
LYNCH MARTHA+JAMES
10710 49TH AVES , TUKWII,A WA 98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: BLACK'S CARPENTRY INC
Address: 14235 MAPLE VALLEY HY , RENTON WA 98058
Contractor License No: BLACKCI915RG
Lender:
Name:
Address:
Phone: • 206 296-7437
Phone: 206 713-8920
Expiration Date: 12/07/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS .AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINT AND STRUCTURE INCLUDING SOUND INSULATION AS WELL AS
WINDOWS, DOORS, INSULATION, AND ABATEMENT.
Value of Construction: $32,054.00
Type of Fire Protection: NONE
Type of Construction: VB
Electrical Service Provided by: SEATTLE CITY LIGHT
Fees Collected:
International Building Code Edition:
Occupancy per IBC:
$1,165.85
2009
0022
**continued on next page**
doc: IBC -7/10
D13-199 Printed: 06-21-2013
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
N Number: 0
Size (Inches): 0
Sanitary Side Sewer:
Sewer Main Extension: Private:
Storm Drainage:
Street Use: Profit: N
Water Main Extension: Private:
Water Meter:
Permit Center Authorized Signature:
N
S
Date:
Public:
Non -Profit: N
Public:
I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complie hether specified herein or not.
The granting of this permit does not pr e to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature:
/ p /
Date: le/ ///3
Print Name: LC /.S7n o1 C,'07
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
doc: IBC -7/10
D13-199 Printed: 06-21-2013
7: VALIDITY OF PERMIT: The issuance or gr g of a permit shall not be construed to be a t for, or an approval of,
any violation of any of the provisions of the ng code or of any other ordinances of the C f Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D13-199 Printed: 06-21-2013
CITY OF TUKWIL.
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://wwwci.tukwila.wa.us
Building Permit No.
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
Pim
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.: 5476800132
Site Address: 10710 49th Ave. S.
Tenant Name: Martha and James Lynch
Suite Number:
Property Owners Name: Martha and James Lynch
Mailing Address: 10710 49th Ave. S.
Floor:
New Tenant: 0 Yes ® ..No
Tukwila
WA
98178
City
State
Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296-7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker@kingcounty.gov
City State
Fax Number: (206) 269-7315
Zip
GENERAL CONTRACTOR INFORMATION --
(Contractor
(Contractor Information for Mechanical (pg 4) for P1lumbing and Gas Piping (pg 5))
P91/1 0 14 t-tsl
Company Name:
not yet awarded Q \ VW S
CMr1 l(/V,
Mailing Address:
City
Contact Person: Day Telephone:
Fax Number:
Expiration Date:
E -Mail Address:
Contractor Registration Number:
State
Zip
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Jesse Holgate or Timothy Fenlason
E -Mail Address: Jesse@smstemper.comltfenlason@jonespayne.cq
City State
Day Telephone: (206) 624-2777
Fax Number: (206) 624-2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
H:\Apphcations\Forms-Applications On Line\2009 Applications \1-2009 - Permit Appl cation.doc
Revised: 1-2009
hh
city
Day Telephone:
Fax Number:
State
Zip
Page 1 of 6
BUILDING PERMIT INFO ION — 206-431-3670
•
Valuation of Project (contractor's bid price): $ 32,054 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? 0 Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact:
Handicap:
Will there be a change in use? ❑ Yes No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm
❑ None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No
If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forms-Applications On Line\2009 Applications \1-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1' Floor
1,120
2nd Floor
3rd Floor
Floors thru
Basement
1,120
Accessory Structure*
Attached Garage
Detached Garage
t
Attached Carport
f
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact:
Handicap:
Will there be a change in use? ❑ Yes No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm
❑ None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No
If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forms-Applications On Line\2009 Applications \1-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR • IZ ! ENT:
Signature:
Date: `i cr 10 (0
Print Name: Tim• y J. FenI. % SM Stemper Architects, PLLC Day Telephone: (206) 624-2777
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
City
State
Zip
Date Application Accepted:
a„ [051 15
Date Application Expires:
1 21 Js
(3
Staff Initials:
H:Wpplications\Forms-Applications On Line\2009 Applications \1-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 6 of 6
PLUMBING AND GAS PIPINRMIT INFORMATION 206-43
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Int'I Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Sewer:
Indicate type of plumbing fixtures and/or gas piping ousts bein:. stalled and the quantity below:
Fixture Type:
Qty
Fixture Type:
1 .
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
ood-waste grinder,
mercial
Floor Drain
Shower, single head trap
Lavatory
W. fountain
Receptor, indirect waste
Sinks
Urinals
Water ► 'set
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater a ' i /or vent
Industrial to treatment
interceptor, in ding trap
and vent, excep or kitchen
type grease interc4 ors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Repair i alteration of
water r s ing and/or water
treats -nt equipment
Repair or alteration k
drainage or vent pipin s
Medical gas piping
system serving 1-5
inlets/outlets for a
specific gas
Each additional medical
gas inlets/outlets greater
than 5
B kflow protective
vice other than
.tmospheric-type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
srotection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:\Applications\Forms-Applications On-Line\2009 Applications\I-2009 Permit Application.doc
Revised: 1-2009
bh
Page 5 of 6
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.gov
Parcel No.: 5476800132
Address: 10710 49 AV S TUKW
Suite No:
Applicant: LYNCH RESIDENCE
RECEIPT
Permit Number: D13-199
Status: PENDING
Applied Date: 06/05/2013
Issue Date:
Receipt No.: R13-01829
Payment Amount: $1,165.85
Initials: JEM Payment Date: 06/06/2013 12:31 PM
User ID: 1165 Balance: $0.00
Payee: PAMELA KUEHL WITH KING COUNTY (OVER THE PHONE)
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 051115
ACCOUNT ITEM LIST:
Description
1,165.85
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100
000.345.830
640.237.114
Total: $1,165.85
703.85
457.50
4.50
Prinforl• na_na_/n1s
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 ;rte, (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
/_ A \ JZ> .1.
Type Inspection:
r: )1/41,4--( D
t
. (O,'iG
Addres r] , s p L
Date Called:
Special Instructions:
/
/
Date Wanted
~2./ �
1m7
'I'
P. m.
Requester:.
Phone No:
6
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
/S(:))
Insp
/ \ i t Dater?—
It
REINSPECTION FEE REQIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
PERMIT COORD CON
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: D13-199 DATE: 06/05/13
PROJECT NAME: LYNCH RESIDENdE
SITE ADDRESS: 10710 49 AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:'
;IN OUV c.(3
ID9lain Division
Public Works
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete 17:1
Incomplete ❑
DUE DATE: 06/06/13
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
TUES/THURS ROUTING:
Please Route
REVIEWER'S INITIALS: DATE:
Structural Review Required ❑ No further Review Required ❑
APPROVALS OR CORRECTIONS:
DUE DATE: 07/04/13
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED
Departments issued corrections:
Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials:
Contractors or Tradespeople Per Friendly Page
General/Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name BLACKS CARPENTRY INCORPORATED UBI No. 602058636
Phone 2067138920 Status Active
Address 14235 Maple Valley Highway License No. BLACKCI915RG
Suite/Apt. License Type Construction Contractor
City Renton Effective Date 12/7/2009
State WA Expiration Date 12/7/2013
Zip 98058 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
ated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
BLACKCI004N1
BLACKS CARPENTRY
INCORPORATED
Construction
Contractor
General
Unused
8/21/2000
9/20/2002
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
BLACK, LAWRENCE
President
12/07/2009
Amount
GREGORY, LELAND WARD
Secretary
12/07/2009
77 -NPP -4-
029885
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
CBIC
SI4617
11/16/2009
Until Cancelled
$12,000.00
12/07/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
2
Nevada Capital
Ins Co
77 -NPP -4-
029885
11/16/2012
11/12/2013
$1,000,000.00
11/08/2012
Contractors
1
Bonding a
C11S14617
11/16/2009
11/16/2012
$1,000,000.0010/13/2011
Insuranc
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
httns://fortress.wa.gov/lni/bbin/Print.asnx 06/21/2013
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00782C12 BID PACKAGE S-35
3-53-0058-045
FILE COPY
Permit No....tajaLai•
Phan review approval Is sublectto errors end omissions.
Approval of construction documents �. Receipt
authorize
the vio4a�on of any adopted � acknowledged:
Ini approved Field Copy a
Dam
tlty Of'Nkwila
BUILDING DIVISION
SCOPE OF WORK
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE
MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND
SPECIFICATIONS INCLUDING BUT NOT LIMITED TO:
APPLICABLE
YES NO
L SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL -FRAMED ACOUSTICAL WINDOWS.
X
2. CUT DOWN OF WINDOWS TO COMPLY UJITH EGRESS REQUIREMENTS.
X
3. INFILL OF EXISTING OPENINGS.
X
4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS.
X
5. INSTALLATION OF STORM DOORS.
X
6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS.
X
1. INSTALLATION OF SECONDARY SKYLIGHTS.
X
8. INSTALLATION OF PET DOORS.
X
9. INSTALLATION OF FIREPLACE FRESH AIR VENT.
X
10. INSTALLATION OF CHIMNEY CAP.
X
11. REGULATED MATERIALS ABATEMENT.
X
12. ATTIC VENT BAFFLES.
X
13, INSTALLATION OF ATTIC INSULATION.
X
14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND
ASSOCIATED DUCTING.
X
15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND
ASSOCIATED DUCTING.
X
16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION.
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCHITECTURAL MODIFICATIONS.
X
18. INSTALLATION OF SMOKE DETECTORS.
X
19. NEW ELECTRICAL PANEL / SERVICE.
X
20. KNOB AND TUBE WIRING.
X
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
Electrical
Plumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may in;.Iude additional plan review fees.
SITE AND BUILDING INFORMATION
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
JURISDICTION:
Department or Planning and Development
City of Tukwila, WA
APPLICABLE CODES:
2009 International Residential Code,
International Fire Code,
international Mechanical Code
5416800132
ZONING: SF1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
v B NON SPRINKLERED
LEGAL DESCRIPTION:
THE SOUTH 62 FEET OF THE NORTH 153 FEET OF THAT PORTION OF TRACT 15, MERRICKS ACRE TRACTS DIVISION NO. 2
ADDITION TO THE CiTY OF SEATTLE, ACCORDING TO PLAT RECORDED IN VOLUME 12 OF PLATS, PAGE 41, IN KING
COUNTY, WASHINGTON, LYING SOUTH OF SOUTH 101th STREET AS CONDEMNED INKING COUNTY SUPERIOR COURT CAUSE
NO. 191022, EXCEPT ANY PORTION CONDEMNED FOR 49th AVENUE SOUTH IN KING COUNTY SUPERIOR COURT CAUSE
NUMBER 191022 AND 266632.
REVIEWED FOR
CODE COMPLIA VCE
APPROVED
JUN 21 2013
BUILp N f'
DRAWING INDEX
T0.0 TITLE SHEET, PROJECT INFO.
41.0 FLOOR PLANS 4 NOTES
.41.1 FLOOR PLANS 4 NOTES
42.0 WINDOW TYPES, SCHEDULE 4 DETAILS
A2.1 DOOR TYPES, SCHEDULE 4 DETAILS
422 MISCELLANEOUS DETAILS
42.3 WINDOW FLASHING DETAILS
MI.0 LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DUJG INDEX
M2.0 MECHANICAL PLANS AND DETAILS
E1.0 ELECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206. 296. 0190
Contact: Sharyn Parker
E-mail: Sharyn.Parker*kingcounty.gov
ARCHITECT:
S.M. Stemper Architects P.L.L.C.
4000 Delridge Way SUJ, Suite 200
Seattle, WA 98106
Ph: 206. 624. 2111
Fax; 206. 624. 2913
Contact: Jerry Osborn, Melody Leung
E-mail: jerryssmstemper.com
melody msmstemper.com
ACOUSTICAL ENGINEER:
554 Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206. 539. 0819
Fax: 206. 839. 0824
Contact: Mohamed Alt. Allaoua
E -ma i l: mohamedessaacoustics.com
MECI4ANiCAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St., Suite 201
Seattle, WA 98119
Ph: 206. 318. 0569
Fax: 206. 318. 0641
Contact: Dylan Turner
E-mail: DylanTsgreenbusch.com
ELECTRICAL ENGINEER:
Tres West Engineers
2102 5. 42nd Street, Suite 301
Tacoma, UJA 98409
Ph: 253. 412. 3300
Fax: 253. 412. 3463
Contact: Brent Rollins
E-mail: bcrstreswest.com
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph: 206. 232. 9639
Fax: 206. 162. 41180
Contact: Tim Ogden
E-mail: tim ogdenspbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123, North Washington 5t. *200
Boston, MA 02114
Contact: Tim Fenlason,
Cynthia Maeda
E-mail: trenlasonmjonespayne.com
CMa eda ejonespayne.com
STRUCTURAL ENGINEER
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 98121
Ph: 206. 622. 4580
Fax: 206. 622. 0422
Contact: Ron Martinson
E-mail: ronmmpsm-engineers.com
RECEIVED
CITY OF TUKWILA
VICINITY MAP (NTS)
JUN 052013
PERM i UtN I ER
Int
ViSiON
4220
REGISTERED
A HI'i'ECJ
SCOTT WTEMPEZ
STATE 0= I SHINGTON'
OCTOBER 19, 2012
0810.03.2324
0
z
0
z
w
z
z
0
0
0
z
MPROVEMENTS
>-
0
w
w
Lu
0
1-1z
I_I_
0
Lu
� r
AIP NUMBER
3-53-0058-045
0
F -
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
PROJECT
INFORMATION,
DRAWING
INDEX,
DIRECTORY
T0.0
0810.03.2324
SPECIAL NOTES:
L LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 II 01
AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
2. REFERENCE S/A22 FOR SMOKE/ CARBON MONOXIDE DETECTOR
INSTALLATION DETAIL.
FAMILY
ROOM
STUDY
LAUNDRY
(E)
FIREPLACE
INSERT
GENERAL NOTES
I. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH
DAY. HOMEOUJI`IERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, MD REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 9:00 AM AND 5:00 PM.
6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED.
1. ADD SOLID WOOD BLOCKING AT WINDOWS.
8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH. AS CLOSELY AS POSSIBLE TO EX15TING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY -ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
15. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS SHEET.
I. CONTRACTOR 15 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 411. 4 AFTER 5:00 PM.
BATH
/
BEDROOM
3
LOWER FLOOR PLAN
1/4"=1'-0"
A. WEST ELEVATION
KITCI-1EN
(E)
FIREPLACE
INSERT
LIVING
ROOM
B. NORTH ELEVATION
PLAN KEYNOTES
ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE.
O DEMOLISH EXISTING DOOR(6), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME,
2 STORM DOOR REF. DOOR SCHEDULE.
OCOORDINATE CEILING GRILL WITH MECHANICAL DOCUMENTS.
O COORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA.
DETAIL.
DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/,42.2 FOR
O MECHANICAL DOCUMENTS.
O BLENDING UNIT LOCATED AND INSTALLED IN SOFFIT WITH 16"XI6" ACCESS HATCH, REF. MECH. DOCUMENTS FOR
DOCUMENTS FOR SPEED CONTROL AND DISCONNECT. REF. 3/422 FOR DETAIL.
O INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE WITH MECHANICAL
ELECTRICAL DOCUMENTS.
O DEMOLISH WALL FINISH UNDER (E) WINDOW SILL TO INSTALL NEW 4X4 POST. INSTALL NEW POST AND PATCH
ADJACENT FINISH. DEMOLISH (E) WINDOW, CASING AND TRIM. SPLIT (E) OPENING AND INSTALL (2) ACOUSTICAL
AND I) REF. WINDOW SCHEDULE ANP 1/422 FOR PETAL.
,.»: .. ..M -,4 4... u. f.•
V. •i 1 -,'••
..... v,..',.1:. • vo•'t
..*.44.01-,;."
....... . ........_. ..-......».....
CASING, TRIM, THRESHOLD AND
REF. MECH. FOR INSTALLATION
DETAIL. COORDINATE WITH
UNIT, REF. ELECT.
AND
WALL TO MATCH
WINDOWS (H
.r• . . K... .r. ..1.-'..S.A. . .. ..
••
- I , .,( 4 •i•,,'`4.7`
teite,.1911 ,,,,;..1.. l... 1i .
t-,;." , ('• ff i. ; •,.
,.„.ar.ar.r h++1lM W+Mn..w.w•r.....'
ACCESS TO SITE AND PARKING
I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
DINING
ROOM
1-
LU
0
O
U
BEDROOM
22" x 30" EXIST.
ATTIC ACCESS
PANEL
—W-
422
A
MAIN FLOOR PLAN
1/4" = 1' - 0"
C. EAST ELEVATION
LEGEND
A
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR/ STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
BATH
BEDROOM
2
D
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 21 2013
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
JUN 052013
PERMIT CENTER
D. SOUTH ELEVATION
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE
FEATHER TEXTURED CEILING OVER AT A
MIN. OF 24" FROM EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
REF. MECH. 4 ELECT.
REF. GENERAL NOTE 11
r------ ATTIC INSULATION
ATTIC INSULATION DAM
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
SG INSTALL BATTERY OPERATED SMOKE /
CARBON MONOXIDE DETECTORS
ISAS GAS METER
SOFFIT FOR MECHANICAL DUCTING
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
4220
REGISTERED
A;CHITECT
COTT liTEMPE'
STATE OF •SHINGTON
OCTOBER 19, 2012
0810.03.2324
0
a.
J
z
0
z
Ct
w
z
>
z
0
0
z
MPROVEMENTS
>-
0
w
w
w
0
z
LL
U
J
z
w
0
(1)
w
AIP NUMBER
3-53-0058-045
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
NOTES
A1.0
0810.032324
SPECIAL NOTES:
1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 11 01
AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
2. REFERENCE 5/422 FOR SMOKE/ CARBON MONOXIDE DETECTOR
INSTALLATION DETAIL.
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES 45 REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 5:00 AM EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
1. ADD SOLID WOOD BLOCKING AT WINDOWS.
8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
B. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
11. ALL WORK AREAS SHALL BE BROOM -GLEANED AT TI -4E END OF EACH WORK DAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS ANp/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY TI -IE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS 51-IALL BE CONCEALED.
11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK. REFER TO ELECTRICAL
FOR TIMER LOCATION
18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS SHEET.
19. CONTRACTOR 15 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20, MAXIMUM POWER OUTAGE IS EIGHT HOURS. POUTER MUST BE PROVIDED AT RESIDENCE BEFORE S:00 AM. 4 AFTER 5:00 PM.
•
L
n
U
J
l
22" x 30" EXIST.
ATTIC ACCESS
PANEL
J
P
r
—J
L
L
26'-1"
1
1
..................
1
14'-6"
A. WEST ELEVATION
ATTIC PLAN
114"=1'-O"
B. NORTH ELEVATION
PLAN KEYNOTES
ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE.
DEMOLISH EXISTING DOOR(S), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND
O STORM DOOR REF. DOOR SCHEDULE.
OCOORDINATE CEILING GRILL WITH MECHANICAL DOCUMENTS.
O COORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION
DETAIL.
DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/42.2 FOR DETAIL. COORDINATE WITH
O MECHANICAL DOCUMENTS.
O BLENDING UNIT LOCATED AND INSTALLED IN SOFFIT WITH 16"X16" ACCESS HATCH, REF. MECH. DOCUMENTS FOR UNIT, REF. ELECT.
DOCUMENTS FOR SPEED CONTROL AND DISCONNECT. REF. 3/422 FOR DETAIL.
O INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE WITH MECHANICAL AND -
ELECTRICAL DOCUMENTS.
O DEMOLISH WALL FINISH UNDER (E) WINDOW SILL TO INSTALL NEW 4X4 POST. INSTALL NEW POST AND PATCH WALL TO MATCH
ADJACENT FINISH. DEMOLISH (E) WINDOW, CASING AND TRIM. SPLIT (E) OPENING AND INSTALL (2) ACOUSTICAL WINDOWS (H
AND I) REF. WINDOW SCHEDULE AND 1/422 FOR DETAIL.
1 i` t
, t ,
l 4 1
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
C. EAST ELEVATION
J
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 21 2013
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
JUN 052013
PERMIT CENTER
LEGEND
r
A
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR/ STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
D. SOUTH ELEVATION
bi°6-14/7
1111111111111
c
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE
FEATHER TEXTURED CEILING OVER AT A
MIN. OF 24" FROM EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
REF. MECH. 4 ELECT.
REF. GENERAL NOTE 11
r----- ATTIC INSULATION
ATTIC INSULATION DAM
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
SC INSTALL BATTERY OPERATED SMOKE /
CARBON MONOXIDE DETECTORS
15,45GAS METER
SOFFIT FOR MECHANICAL DUCTING
j
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
4220
REGISTERED
ALHITECT
COTT TEMPE
STATE OR SHINGTON
OCTOBER 19, 2012
0810.03.2324
NTERNATIONAL AIRPORT
KING COUNTY
z
w
w
0
0
w
Nw
1t
w
0
z
1 -
LL
OL
0
Ct
Q
1---
0 0
(1)
w
OL
AIP NUMBER
3-53-0058-045
z
0
F—
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
NOTES
A1 .1
0810.03.2324
WINDOW TYPES
1.
FIXED
2.
HORIZONTAL
XX SLIDER
G
3.
FIXED OVER
SLIDER/ FIXED/ SLIDER
(SLIDER MAY BE INSTALLED ON
TOP)
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
DETAIL
SET
A
ENTRY
1
4'-5" x 3'-11"
STAIN/STAIN
SAFETY GLAZING REQUIRED,
RAISE (E) SILL HEIGHT FOR FRAMING, REF. 6/42.2 FOR DETAIL
1/42.0
B
ENTRY
I
I'-6" x 6'-8"
STAIN/STAIN
SAFETY GLAZING REQUIRED, OBSCURE GLASS
SHRINK WINDOW WIDTH FOR FRAMING, REF. 6/42.2 FOR DETAIL
2/42.0
C
LIVING ROOM
3
10'-0" x 4'-10"
STAIN/STAIN
SAFETY GLAZING REQUIRED, REMOVE 4 REINSTALL (E) SHUTTERS
3/42.0
D
KITCHEN
2
5'-11" x 2'-11"
STAIN/STAIN
TYP AT HEAD AND JAMBS.
3/A2.0
E
KITCHEN
2
2'-11" x 2'-10"
STAIN/STAIN
SAFETY GLAZING REQUIRED
3/42.0
F
BEDROOM 1
2
1'-11" x 2'-11"
STAIN/STAIN
SAFETY GLAZING REQUIRED
3/42.0
G
BEDROOM 2
2
T-11" x 2'-11"
STAN/STAIN
.1
3/A2.0
H
FAMILY ROOM
2
4'-10" x 2'-4"
STAIN/STAIN
SAFETY GLAZING REQUIRED, REMOVE 4 REINSTALL (E) SHUTTERS
3/A2.0
I
FAMILY ROOM
2
4'-10" x 2'-4"
STAIN/STAIN
SAFETY GLAZING REQUIRED, REMOVE 4 REINSTALL (E) SHUTTERS
3/42.0
J
FAMILY ROOM
2
4'-11" x 2'-5"
STAIN/STAIN
SAFETY GLAZING REQUIRED
3/A2.0
K
BEDROOM 3
2
1'-11" x 2'-5"
STAIN/STAIN
SAFETY GLAZING REQUIRED, REMOVE 4 REINSTALL (E) SHUTTERS
3/A2.0
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET.
SLOPE
E
I" min.
1/Z." min.
I I
HEMMED EDGE J
END CLOSURE
C-10 HEAD FLASHING DETAIL TYP.
"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 21 2013
City of Tukwila
BUILDING DIVISION
rifect
RECEIVED
CITY OF TUKWILA
JUN 052013
PERMIT CENTER
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
REGISTERED
1\, [ECT
../SCOTT+ °TEMIPE.
• STATE 0=) SHINGTON'''
OCTOBER 19, 2012
0810.03.2324
0
0
J
z
0
z
w
z
z
0
U
z
AIP NUMBER
MPROVEMENTS
>-
0
cw
w
w
0
z
LL
L1.1
3-53-0058-045
z
0
Q
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.2324
I
I
III
(E) WD. SIDING
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
\ J
(E) GWB
CAREFULLY LIFT (E) WALL UNDERLAYMENT
J
lEJ GWB
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
)
AND INSTALL SELF -ADHERING MEMBRANE\
PENETRATION FLASHING. LAP (E) WALL
f
(E) WALL UNDERLAYMENT
ACOUSTICAL WINDOW
ASSEMBLY
-
P
P
TYP AT HEAD AND JAMBS.
�li
�,FLASHING.
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
UNDERLAYMENT OVER PENETRATION
TYP AT HEAD AND JAMBS.
i
I(E)
I(E)
_
C -_______------)FLASHING.
WALL UNDERLAYMENT
.1
REMOVE (E) WOOD SIDING FOR
1
-
REMOVE (E) WOOD SIDING FOR
1
I
'�J
EXTERIOR SHEATHING
a
INSTALLATION OF NEW WINDOW
SELF ADHERING
ASSEMBLY AND TRIM. REPLACE OR RE -
1
( /
��7
MEMBRANE
TRIM- MATCH (E) TRIM. PRIME ALL
r
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
111MEMBRANE
---
SELF ADHERING
SIDES AND PAINT TO MATCH (E) TRIM.
►
NEW 2"X STUD FRAMING
INSTALL SIDING AS REQ'D. MAINTAIN `r
j
COLOR TO BE FIELD DETERMINED
I
(E) COURSING. PAINT MODIFIED SIDING
I I
TOUCH UP PAINT, AS REQ'D
f
INSTALL SIDING AS REQ D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
11
I
)
TOUCH UP PAINT, AS REQ'D
i
1
I
TO MATCH (E) SIDING.
1101
I
I
I
)
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
TO MATCH (E) SIDING.
I
CONTINUOUS
PRE -PRIMED, GALY SHEET METAL
1
I
`
SEALANT, TYP.
O
L
�
PRE -PRIMED, GALY SHEET METAL -
FLASHING W/ CLOSURE UNDER
,�
%>
I I
\ 1
FLASHING UNDER SELF -ADHERING ,
%/ /
I
I
END m
I�
SOLID WOOD TRIM
SELF -ADHERING MEMBRANE. COLOR t0
i
-
COLOR TO BE SELECTED IN -
10
SOLID WOOD TRIM
_
•
UD JAMB LINING
BE SELECTED IN THE FIELD
a �
��
,
_
_MEMBRANE.
SEALANT
THE FIELD
a
_
L_�
-
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
-
I�I
LI
!tet
WD. JAMB LINING
ll lr
�_�
TRIM- MATCH (EJ TRIM. PRIME ALL
•I
WD. JAMB LINING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
0
,
lr
SEALANT
WINDOW
REMOVE (E) WD. SIDING FOR
HEAD/
I
SILL
AT
SIDE LIGHT
SEALANT
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
II II
II
SHIM AS NECESSARY
FILL GAP W/ BATT
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
II II
II II
SHIM AS NECESSARY
FILL G AP UJ/ BATT
REMOVE (E) WD. SIDING FOR
WINDOW
HEAD
INSULATION
WINDOW
REMOVE (E) WD. SIDING FOR
HEAD
INSULATION
INSTALLATION OF NEW WINDOW TRIMS
AND REATTACHMENT OF (E) SIDING TO
WINDOW OPENING FRAMING. LIFT (E)
WALL UNDERLAYMENT AND INSTALL/
WINDOW / NAILING FLANGE OVER SELF
1
(E) GWBWALL
INSTALLATION OF NEW WINDOW TRIMS
AND REATTACHMENT OF (E) SIDING TO
WINDOW OPENING FRAMING. LIFT (E)
UNDERLAYMENT AND INSTALL
(E) GWB
INSTALLATION OF NEW WINDOW TRIMS
REATTACHMENT OF (E) SIDING TO
WINDOW OPENING FRAMING. LIFT (E)
WALL UNDERLAYMENT AND INSTALL
(E) GUS
ADHERING MEMBRANE PENETRATION
-
WINDOW / NAILING FLANGE OVER SELF
ADHERING MEMBRANE PENETRATION
----..j
WINDOW /NAILING FLANGE OVER SELF
ADHERING MEMBRANE PENETRATION
ll
(I
�J
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER '-
I
I
��
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER
II
jl
TOUCH UP PAINT, A5 REQ1D
NAILING FLANGE AND LAP UNDER (E)
II
TOUCH UP PAINT,A5 REQ'D
FLASHING. INSTALL SECOND LAYER OF
>-
SELF ADHERING MEMBRANE OVER
�-
NAILING FLANGE AND LAP UNDER (EJ
i
II
TOUCH UP PAINT, AS REQ D
WALL UNDERLAYMENT. CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. MODIFIED SIDING
CONTINUOUS
SEALANT, TYP.
NAILING FLANGE AND LAP UNDER (E)
CONTINUOUS
WALL UNDERLAYMENT. CAULK NEW
SEALANT, TYP.
WALL UNDERLAYMENT. CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL
1
I
CONTINUOUS
SEALANT, TYP.
AV
VERTICAL SIDING JOINTS 4 SET NAIL
PAINT
SOLID WOOD TRIM
TO MATCH (E) SIDING
phi
\
HEADS FLUSH. MODIFIED SIDING
PAINT
SOLID WOOD TRIM
HEADS FLUSH. PAINT MODIFIED SIDING
\
SOLID WOOD TRIM
(E) WD. SIDING
`
TO MATCH lEJ SIDING
II
1
\
-
`^
TO MATCH (E) SIDING
I
\?
-
a
`
(E) WD. SIDING
Ol
--
(E) WALL UNDERLAYMENT
_
a
11[1:1
\\
\
WD JAMB LINING
"'
Q
PH
N
-
lE) EXTERIOR SHEATHING
SEALANT
(E) WALL UNDERLAYMENT
�1
WD JAMB LINING
(E) WALL UNDERLAYMENT
WD JAMB LINING
(E) EXTERIOR SHEATHING
_
SEALANT
�l
(E) EXTERIOR SHEATHING
-
-�
SEALANT
BACKER ROD 4 SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
1�t
_
4 SEALANT
1®_
ISI
ISI
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
II II
ll
II
SHIM AS NECESSARY
FILL GAP W/ BATT
ACOUSTICAL WINDOW ASSEMBLY
WINDOW
II II
III
II II
JAMB
III
INSULATION
BACKER ROD
ACOUSTICAL WINDOW ASSEMBLY
r
SHIM A5 NECESSARY
FILL GAP W/ BATT
WINDOW
I
III
JAMB
INSULATION
WINDOW
JAMB
II
II
" ,
�J
i
&
=
III
II
I"�I
DOOR
II
�J
INSULATION
JAMB
ACOUSTICAL WINDOW ASSEMBLY
''---
H
0
III
0
BACKER ROD 4
SEALANT"
3/4"
ACOUSTICAL WINDOW
BACKER ROD 4 SEALANT
3/4" WOOD SILL
ASSEMBLY
MI
ACOUSTICAL WINDOW
/6
1
''
N'
\
ASSEMBLY
SHIM AS NECESSARY
-
P
PI
SEALANT 4 BACKER ROD
EXISTING FLOOR
WINDOW NAILING FIN -�
I&
j
1
FILL GAP W/ BATT INSULATION
Il
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
\
\
\
(E) W
WOOD 2X STRUCTURE
/�
l
1
SOLID WOOD TRIM
_
4 SEALANT
`
TRIM- MATCH (E) TRIM. PRIME ALL
1
,
STORM DOOR PER SCHEDULE
' ` ' 'Tr
`
SOLID WOOD TRIM
SIDES AND PAINT TO MATCH (E) TRIM.
BACKER ROD
COLOR TO BE FIELD DETERMINED
• - A
•
SILL PAN
i�l-t
•
,
NTINUOUS
SEALANT, TYP.
PRE -PRIMED GALV.
FLASHING- LAP JAMB
FLASHING INTO SILL PAN.
EMBED LAP IN SEALANT. FIELD
PAINT FLASHING - COLOR TO
BE SELECTED IN THE FIELD
WOOD SIDING
CWOOD
WINDOW SILL
- WINDOW DETAIL SET
KERF AS
SHIM A5 NECESSARY
FILL GAP W/ BATT
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
TOUCH UP PAINT, AS REQ'D
REQUIRED FOR WEATHER
INSULATION
STRIPPING INSTALLATION
I
2" MIN.
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
SELF
MEMBRANE
II
DOOR PER SCHEDULE
CONTINUOUS WEATHER-STRIPPING
WINDOW
SILL
& DOOR
HEAD
-------)
(E) GLIB
(E) WD SIDING
WINDOW
SIDING -
SILL
WINDOW
1) I ......
DETAIL SET
WOOD SIDING - WINDOW DETAIL SET
3"=1'-0"
3"=1'-0"
C3) 311= 1' - 01l
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 21 2013
City of Tukwila
BUILDING DIVISION
rifect
RECEIVED
CITY OF TUKWILA
JUN 052013
PERMIT CENTER
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
REGISTERED
1\, [ECT
../SCOTT+ °TEMIPE.
• STATE 0=) SHINGTON'''
OCTOBER 19, 2012
0810.03.2324
0
0
J
z
0
z
w
z
z
0
U
z
AIP NUMBER
MPROVEMENTS
>-
0
cw
w
w
0
z
LL
L1.1
3-53-0058-045
z
0
Q
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.2324
DOOR TYPES
7
i
N/
A
FLUSH SCUD
HALF -LITE 1U/
2 PANELS
UJ/ SAFETY GLAZING
B
FLUSH SCW
DBL. LEAF
HALF -LITE W/
2 PANELS
UJ/ SAFETY GLAZING
C
FLUSH SCUD
3 LITES, 3 PANELS
W/ SAFETY GLAZING
UJ/ OBSERVATION PORT
EXTERIOR
SINGLE LEAF STORM
UJ/ FULL -LITE
SAFETY GLAZING
EXTERIOR
SINGLE LEAF STORM
UJ/ FULL -LITE
SAFETY GLAZING
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
1
ENTRY
C
3'-0 x 6'-8"
STAIN/ STAIN
1-1111-1 / 626
OK -4
LOCK -1
I/A2.1
2
KITCHEN
A
2'-8" x 6'-8"
STAIN/ STAIN
HUJ-1 / 626
DK -3
LOCK -1
2/A2.1
3
DINING ROOM (DBL. LEAF)
B
4'-10" x 6'-8"
STAIN/ STAIN
HUJ-1 / 626
DK -3
LOCK -1
2/A2.1
4
ENTRY
D
3'-0 x 6'-8"
I/42.1
5
KITCHEN
D
2'-8" x 6'-8"
2/A2.1
6
DINING ROOM (DBL. LEAF)
E
4'-10" x 6'-8"
2/A2.1
TYPICAL DOOR SCHEDULE NOTES
1.
2.
3.
4.
5.
WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN
SECTION 08 8000, ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS
AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK.
FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET.
1" min.
1/2." min.
HEMMED EDGE
SLOPE
END CLOSURE
HEAD FLASHING DETAIL TYP.
3"=1'-0"
ACOUSTICAL WINDOW
ASSEMBLY
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM POOR PER SCHEDULE
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER-STRIPPING
(E) WOOD 2X STRUCTURE
2" MIN.
SOLID WOOD TRIM
51-1IM AS NECESSARY
PILL GAP W/ BATT
INSULAT ION
DOOR PER SCHEDULE
DOOR HEAD & WINDOW SILL/ JAMB (SIM)
REMOVE (E) WD. SIDING FOR INSTALLATION
OF NEW DOOR TRIMS AND REATTACHMENT
OF (E) SIDING TO DOOR OPENING FRAMING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK
NEW VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PAINT MODIFIED SIDING TO
MATCH (E) SIDING
(E) WOOD SIDING
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
(E) EXTERIOR SHEATHING
TOUCH UP PAINT, AS REQ'D
CONTINUOUS
KERF A5 REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER-STRIPPING
JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
SILL IN HEAD OF SEALANT
DOOR JAMB
DOOR SILL
SEALANT, TYP.
EXISTING FRAMING
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP UJ/ BATT
INSULATION
DOOR PER SCI-IEDULE
WOOD SIDING - DOOR DETAIL SET
3"=1'-0"
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW DOOR ASSEMBLY
AND TRIM. REPLACE OR RE INSTALL
SIDING AS REQ'D. MAINTAIN (E)
COURSING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
PRE -PRIMED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MIN.
(E) EXTERIOR SHEATHING
SELF -ADHERING
MEMBRANE
TOUCH UP PAINT AS, REQ'D
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
514IM A5 NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF A5 REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
REMOVE (E) UJD. SIDING FOR INSTALLATION
OF NEW DOOR TRIMS AND REATTACHMENT
OF (E) SIDING TO DOOR OPENING FRAMING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK
NEW VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PANT MODIFIED SIDING TO
MATCH (E) SIDING
(E) WOOD SIDING
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KERF A5 REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER-STRIPPING
JAMB BEYOND
DOOR HEAD
"_")
(E) EXTERIOR SHEATHING
TOUCH UP PAINT, A5 REQ'D
CONTINUOUS
DOOR JAMB
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
SILL IN HEAD OF SEALANT
DOOR SILL
SEALANT, TYP.
EXISTING FRAMING
SOLID U)OOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
WOOD SIDING - DOOR DETAIL SET
3"=1'-0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 21 2013
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
JUN 052013
PERMIT CENTER
S.M.STEMPEP
ARCHITE CTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 08106
(206) 624-2777 • FAX (206) 624-2973
REGISTERED
•AqHIIEC'f
COTT TEMP-'
STATE OF ! HINGTON`
OCTOBER 19, 2012
0810.03.2324
MPROVEMENTS
>-
0
w
w
cc
w
0
z
U
ccQ
J
Q
H
Z
W
D
W
AIP NUMBER
3-53-0058-045
z
0
1-
z_
Cn
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.2324
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF VENT FIXTURE AND
FLASHING. REPLACE OR RE INSTALL
SIDING AS REQ'D. MAINTAIN (E)
COURSING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
PRE -PRIMED, GALV. SHEET METAL
FLASHING W/ F.F. END CAPS UNDER
SELF -ADHERING MEMBRANE. EXTEND
FLASHING 4" UP WALL. PAINT COLOR TO
BE SELECTED IN TIE FIELD
PAINT VENTILATION HOOD,
COLOR TO BE SELECTED IN
THE FIELD
EXTERIOR VENTILATION HOOD.
REF. MECH- PAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
(E) WALL UNDERLAYMENT
SELF -ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
2X BLOCKING
2X2 CONTINUOUS PRESSURE
TREATED BLOCKING, 4 SIDES
REMOVE / REPLACE (E) SIDING AS
REQUIRED.
(E) HEADER
WINDOW ASSEMBLY
PER SCHEDULE
(E) 2x FRAMING
NEW 4x4 HEADER
DOOR
PER SCHEDULE
AIR INTAKE DETAIL AT EXTERIOR
3"= 1'-0"
2X BLOCKING
u
NEW DOUBLE 2x6
NEW 2x
TRIM STUDS
WINDOW ASSEMBLY
PER SCHEDULE
FRAMING ANCHOR AT
FLOOR, REQ'D
NOTE: FIELD VERIFY
ALL DIMENSIONS
FRAMING DETAIL AT FRONT DOOR (INTERIOR)
1 = 1 -0
(E) HEADER
WINDOW ASS
PER SCHEDI
(2) NEW OR (!
TO SUPPORT
HEADER. EA.
NEW 4X4 PO
W/ SIMPSON
EACH SIDE T
BOTTOM
(E) 2x
CRIPPLE ST
16" O.C.
NOTE: FIELD
ALL DIMENS
EXISTING ROOF
(E) ROOF FRAMING
(E) EAYE VENT. MAY VERY
AT EACH PROPERTY.
51-01L IN CELLULOSE
INSULATION WITH A COMBINED
VALUE OF NOT LESS THAN
R-38
INSULATION DAM
(E) WALL FRAMING
VERT. CHASE WALL
2x4 FRAMING
DUCT PER MECH.
WD BASE- PAINT TO
MATCH (E) WALLS
TRIM FINISH FLOOR AND
UNDERLAYMENT TO F.O.
(E) WALL. BUTT %" TYPE
X GYP TIGHT TO SUBFLR.
(E) FLOOR FRAMI
(E) GWB
DUCT
CHASE
NEW GRILL COORDINATE WITH
MECHANICAL
VERTICAL CHASE DETAIL
HOLD MINIMUM, BUT A5 REQUIRED TO
COORDINATE DUCT UJ/ (E) FLOOR
AND CEILING FRAMING.
DEMOLISH (E) FLOOR
(E) FINISH FLOOR
DEMOLISH (E) GWB
(E) FLOOR CONSTRUCTION
FINISH FLOOR
%" CPX PLYWOOD
2x10 016" O.C.
" GWB
1 1/2" = 1' - 0"
FRAMING DETAIL AT WINDOW H (INTERIOR)
•
EXISTING
CEILING
STRUCTURE
1 1111111111111
,1
CEILING MOUNTING BRACKET
IJ" X 1Y" ANGLE IRON LEG BOLTED
TO (E) STRUCTURE
WOOD (E) EXTERIOR
WALL FRAMING
DUCT PER MECH.
UJ/ IN SOFFIT
1x2 WD BASE- PAINT TO
MATCH (E) WALLS
TRIM FINISH FLOOR AND
UNDERLAYMENT TO F.O.
(E) WALL. BUTT 5/9" TYPE
X GYP TIGHT TO SUBFLR
MECH UNIT AND DUCTS -
REF MECHANICAL
HOLD TIGHT TO (E)
CEILING STRUCTURE
ABOVE
CONTINUOUS VIBRATION
DAMPENING PAD RE:
MECHANICAL
WHERE WIDTH OF SOFFIT EXCEEDS
16", INSTALL 2X4 STUDS m 16" O.C.
BLENDING AIR UNIT DETAIL
5/8" GWB- PAINT TO MATCH (E)
TEXTURE 4 COLOR OF CEILING.
2x2 CONT. NAILER
(E) CLOSET
(E) GWB
DUCT
CHASE
16"X16" ACCESS
HATCH FOR
MAINTENANCE
HOLD MINIMUM, BUT AS REQUIRED TO
COORDINATE DUCT UJ/ (E) FLOOR
AND CEILING FRAMING. RE -BUILD (E)
CLOSET SHELVING AND ROD TO
ACCOMMODATE CHASE
(E) FINISH FLOOR
NOTCH TOP PLATE AND TRIM STUDS
OF PARTITION AS REQ'D TO ACCOMMODATE
PASSAGE OF MECH. COMPONENTS. WALL
PENETRATIONS SHALL BE CUT FULL SIZE
OF SOFFIT AREA, TYPICAL
ANCHOR CEILING NAILER
TO (E) JOIST
WHERE WIDTH OF SOFFIT
EXCEEDS 16", PROVIDE 2X4
SOFFIT FRAMING m 16" O.G.
PROVIDE FINISH -GRADE
PAINTABLE GWB EDGE
AND CAULK JOINT
E
0
i—
r -
5
(E) FLOOR CONSTRUCTION
FINISH FLOOR
%" CDX PLYWOOD
2x10*16"OC
Y2" GWB
2x BLOCKING BETWEEN STUDS
WHICH REQUIRE TRIMMING
2x2 CONT. NAILER
5/8" GWB- PAINT TO MATCH (E) TEXTURE 4
COLOR OF CEILING. MOISTURE -RESISTANT
GWB AT BATHROOM SOFFITS
ENCLOSE DUCTS TIGHTLY, OR TERMINATE
EDGE W/ ADJ ARCHITECTURAL FEATURES
PER PLAN. COORDINATE SOFFIT DIMENSIONS
WITH MECHANICAL CONTRACTOR AND FIELD
CONDITIONS
(E) WD FRAME WALL ASSEMBLY
DUCT CHASE/ SOFFIT DETAIL
1 1/2" = 1' - 0"
CEILING
4"MIN
BEST HERE
ACCEPTABLE
HERE
NOTE: REMOVE EXISTING SMOKE
DETECTORS, CUT AND PATCH CEILING AS
REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND
TEXTURE AND PAINT TO FILL ALL HOLES
LEFT FROM EXISTING CONDITION. PAINT
TO MATCH SURROUNDING CONDITIONS.
SIDE WALL
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 21 2013
BUILDING TukwiIa
DIVISION
DETECTOR INSTALLATION DETAIL TYP.
3=1-0
RECEIVED
CITY OF TUKWILA
JUN 0 5 203
PERMIT CENTER
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
REGISTERED
ACHIIECT
OOTT ETEMPE'
STATE 07 '? ,oHINGT'ON
OCTOBER 19, 2012
0810.03.2324
0
0_
J
z
O
Lt
w
z
z
O
0
z
AIP NUMBER
MPROVEMENTS
>-
0
cw
w
w
O
z
LL
U
J
3-53-0058-045
z
0
I—
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
MISC.
DETAILS
A2.2
0810.03.2324
:MBLY
LE
E)2x
NEW
SIDE
51
%,
/r
/
�',//,�
//
A34
OP AND
L_
I---
DS AT
VERIFY
IONS
4
1
L
FRAMING DETAIL AT WINDOW H (INTERIOR)
•
EXISTING
CEILING
STRUCTURE
1 1111111111111
,1
CEILING MOUNTING BRACKET
IJ" X 1Y" ANGLE IRON LEG BOLTED
TO (E) STRUCTURE
WOOD (E) EXTERIOR
WALL FRAMING
DUCT PER MECH.
UJ/ IN SOFFIT
1x2 WD BASE- PAINT TO
MATCH (E) WALLS
TRIM FINISH FLOOR AND
UNDERLAYMENT TO F.O.
(E) WALL. BUTT 5/9" TYPE
X GYP TIGHT TO SUBFLR
MECH UNIT AND DUCTS -
REF MECHANICAL
HOLD TIGHT TO (E)
CEILING STRUCTURE
ABOVE
CONTINUOUS VIBRATION
DAMPENING PAD RE:
MECHANICAL
WHERE WIDTH OF SOFFIT EXCEEDS
16", INSTALL 2X4 STUDS m 16" O.C.
BLENDING AIR UNIT DETAIL
5/8" GWB- PAINT TO MATCH (E)
TEXTURE 4 COLOR OF CEILING.
2x2 CONT. NAILER
(E) CLOSET
(E) GWB
DUCT
CHASE
16"X16" ACCESS
HATCH FOR
MAINTENANCE
HOLD MINIMUM, BUT AS REQUIRED TO
COORDINATE DUCT UJ/ (E) FLOOR
AND CEILING FRAMING. RE -BUILD (E)
CLOSET SHELVING AND ROD TO
ACCOMMODATE CHASE
(E) FINISH FLOOR
NOTCH TOP PLATE AND TRIM STUDS
OF PARTITION AS REQ'D TO ACCOMMODATE
PASSAGE OF MECH. COMPONENTS. WALL
PENETRATIONS SHALL BE CUT FULL SIZE
OF SOFFIT AREA, TYPICAL
ANCHOR CEILING NAILER
TO (E) JOIST
WHERE WIDTH OF SOFFIT
EXCEEDS 16", PROVIDE 2X4
SOFFIT FRAMING m 16" O.G.
PROVIDE FINISH -GRADE
PAINTABLE GWB EDGE
AND CAULK JOINT
E
0
i—
r -
5
(E) FLOOR CONSTRUCTION
FINISH FLOOR
%" CDX PLYWOOD
2x10*16"OC
Y2" GWB
2x BLOCKING BETWEEN STUDS
WHICH REQUIRE TRIMMING
2x2 CONT. NAILER
5/8" GWB- PAINT TO MATCH (E) TEXTURE 4
COLOR OF CEILING. MOISTURE -RESISTANT
GWB AT BATHROOM SOFFITS
ENCLOSE DUCTS TIGHTLY, OR TERMINATE
EDGE W/ ADJ ARCHITECTURAL FEATURES
PER PLAN. COORDINATE SOFFIT DIMENSIONS
WITH MECHANICAL CONTRACTOR AND FIELD
CONDITIONS
(E) WD FRAME WALL ASSEMBLY
DUCT CHASE/ SOFFIT DETAIL
1 1/2" = 1' - 0"
CEILING
4"MIN
BEST HERE
ACCEPTABLE
HERE
NOTE: REMOVE EXISTING SMOKE
DETECTORS, CUT AND PATCH CEILING AS
REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND
TEXTURE AND PAINT TO FILL ALL HOLES
LEFT FROM EXISTING CONDITION. PAINT
TO MATCH SURROUNDING CONDITIONS.
SIDE WALL
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 21 2013
BUILDING TukwiIa
DIVISION
DETECTOR INSTALLATION DETAIL TYP.
3=1-0
RECEIVED
CITY OF TUKWILA
JUN 0 5 203
PERMIT CENTER
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
REGISTERED
ACHIIECT
OOTT ETEMPE'
STATE 07 '? ,oHINGT'ON
OCTOBER 19, 2012
0810.03.2324
0
0_
J
z
O
Lt
w
z
z
O
0
z
AIP NUMBER
MPROVEMENTS
>-
0
cw
w
w
O
z
LL
U
J
3-53-0058-045
z
0
I—
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
MISC.
DETAILS
A2.2
0810.03.2324
LIFT (E) WALL
UNDERLAYMENT
AWAY LOOSELY
FROM (E) SHEATHING
AT JAMBS AND HEAD
BUTTERFLY
CORNERS, TYP.
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
LAP SILL MEMBRANE
FLASHING 2-1/2"
OVER (E) BLDG.
PAPER AT SILL.
EXTEND 1 i" BEYOND
RO. AT EA. END OF
SILL.
(E) WALL
UNDERLAYMENT
AT SILL
1
(E) SHEATHING
GUT SILL
FLASHING TO
EDGE OF R.O. AS
SHOWN.
ADHERE
MEMBRANE
FLASHING t0
OUTSIDE FACE
OF UJALL
SHEATHING
1" MIN
MEMBRANE FLASHING AT SILL
5 J
13UTTERFFLY CORNER FLASHING
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD. \--,—
(E) SIDING NOT
SHOWN FOR CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
514OULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) WALL
UNDERLAYMENT
AT SILL.
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
4 WINDOW MEMBRANE INSTALLATION
i SCALE: NTS
REMOVED
EDGE OF ( E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) UJALL
UNDERLAYMENT
BACK DOWN
OVER FLANGE
FLASHING AT
JAMBS
\7l
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
r
WHERE REQUIRED, TRIM
(E) WALL
UNDERLAYMENT AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLA ING AND
WINDOW TRI
(FOLLOWI STEPS).
L J
HEAD FLASHING PREPARATION
SCALE: NTS
(E) WALL
UNDERLAYMENT
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
(z)
CUT JAMB FLASHING TO
EDGE OF WINDOW OPENING
AS SHOWN. EXTEND 1-1/2"
BEYOND EDGE OF
OPENING AT HEAD, JAMBS,
AND SILL.
ADHERE
MEMBRANE
FLASH ING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D
(E) SIDING NOT SHOU,N FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
— INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
/5 MEMBRANE FLASHING AT JAMB
SCALE: NTS
INSTALL SHT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
ALLOW I/8"
BETWEEN FL
BOT. EDGE
SIDING
LEARANCE
SHING AND
(E)
TRIMMED EDGE
OF (E) SIDING,
SHOWN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) WALL
UNDERLAYMENT
3� MEMBRANE FLASHING AT HEAD
SCALE: NTS
INSTALL HEAD
CUT HEAD
FLASHING TO
EDGE OF WINDOW
OPENING 45
SHOWN. EXTEND
1-1/2" BEYOND
R.O. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
UJALL SHEATHING
(TYP. EACH SIDE
OF WALL)
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
ANP FLASHING.
C6
WINDOW FLASHING INSTALLATION
SCALE: NTS
o
0
0
0
0
0
1 1
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
4 WINDOW MEMBRANE INSTALLATION
i SCALE: NTS
REMOVED
EDGE OF ( E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) UJALL
UNDERLAYMENT
BACK DOWN
OVER FLANGE
FLASHING AT
JAMBS
\7l
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
r
WHERE REQUIRED, TRIM
(E) WALL
UNDERLAYMENT AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLA ING AND
WINDOW TRI
(FOLLOWI STEPS).
L J
HEAD FLASHING PREPARATION
SCALE: NTS
(E) WALL
UNDERLAYMENT
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
(z)
CUT JAMB FLASHING TO
EDGE OF WINDOW OPENING
AS SHOWN. EXTEND 1-1/2"
BEYOND EDGE OF
OPENING AT HEAD, JAMBS,
AND SILL.
ADHERE
MEMBRANE
FLASH ING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D
(E) SIDING NOT SHOU,N FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
— INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
/5 MEMBRANE FLASHING AT JAMB
SCALE: NTS
INSTALL SHT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
ALLOW I/8"
BETWEEN FL
BOT. EDGE
SIDING
LEARANCE
SHING AND
(E)
TRIMMED EDGE
OF (E) SIDING,
SHOWN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) WALL
UNDERLAYMENT
3� MEMBRANE FLASHING AT HEAD
SCALE: NTS
INSTALL HEAD
CUT HEAD
FLASHING TO
EDGE OF WINDOW
OPENING 45
SHOWN. EXTEND
1-1/2" BEYOND
R.O. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
UJALL SHEATHING
(TYP. EACH SIDE
OF WALL)
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
ANP FLASHING.
C6
WINDOW FLASHING INSTALLATION
SCALE: NTS
WOOD TRIM INSTALLATION
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
SCALE: NTS
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE 1/4"-3/8" GAP
BETWEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
I: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS
"SELF ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5 AND 6" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW 1445 BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "I AND 8" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAIL 5 REFERS TO WOOD TRIM AND CAULK
JOINTS.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 21 2013
City of BUILDING DIVISION
l3I?
RECEIVED
CITY OF TUKWILA
JUN 0 5 2013
PERMIT CENTER
■
S.M.STEMPER
ARCHITE CTS
A Professional Limited Liability Company
4000 DELRIDGR WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
REGISTERED
AL-TECT
OCTOBER 19, 2012
0810.03.2324
0
a_
J
z
0
w
z
z
0
0
(9
z
MPROVEMENTS
>-
0
w
w
w
0
z
LL
0
LLI
AIP NUMBER
3-53-0058-045
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
FLASHING
DETAILS
A2.3
0810.03.2324
1 1
WOOD TRIM INSTALLATION
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
SCALE: NTS
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE 1/4"-3/8" GAP
BETWEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
I: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS
"SELF ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5 AND 6" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW 1445 BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "I AND 8" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAIL 5 REFERS TO WOOD TRIM AND CAULK
JOINTS.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 21 2013
City of BUILDING DIVISION
l3I?
RECEIVED
CITY OF TUKWILA
JUN 0 5 2013
PERMIT CENTER
■
S.M.STEMPER
ARCHITE CTS
A Professional Limited Liability Company
4000 DELRIDGR WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
REGISTERED
AL-TECT
OCTOBER 19, 2012
0810.03.2324
0
a_
J
z
0
w
z
z
0
0
(9
z
MPROVEMENTS
>-
0
w
w
w
0
z
LL
0
LLI
AIP NUMBER
3-53-0058-045
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
FLASHING
DETAILS
A2.3
0810.03.2324
LOCATION:: 1
SERVING:? RESIDENCE,.
120/240 VOL
10,000 AC,
WIRE.
125 TAMP with MAIN k, BKR
CKT
LOAD DES
11.019
TYPE'
KVA NP
30/2
7
11
13
15.,'
17
19
21
23
VEXISTING LOAD
EXISTING LOAD
'E) ISTING LO
EXISTING LOAD
LISTING. LOAD
15/1
20/1
20/2
EXISTING LOAD
20/2
EX[S1TNG LOAD
EXISTING LOI�D
20/1
HASE?
A/P'
A
B'
A
A
A
1511
2011_
40/2
20/1,
20/1 >.
20/1
20/1
KVA
TYPE
15/1
0/1
2011
20/1.2011
LOAD DESCRIPTION
EXISTING LOADwT
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
CKT
EXISTING LQAD,
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
EXISTING I,.OAR;
EX STING LOAD
BLENDING
1+
14
16
18
20.
22
24
4Q TYPE
1N.LOAD
WH
JTED LOAD,
0,12
0.12
ISOLATED GROUND BUS
El $RAINTIGHT,NEMA3R;ENCLOSURE
.
FEED TFjRU LUGS MAIN BKR SHUNT
DOUBLE LUGS . [) SERVICE' ENTRANCE LABEL
0.03
OTAL LOADS
012; KVA
PAN EL SKIRTS
INTEGRAL TVSS
0.15 KVA
0,63; ANP
SURFACE
FLUSH
PROVIRE:(2jNE At 112 SIZE BREAD S T+D MATCH EXIS1I1NGSYSTEIGI.
RE QNRGURE E7LSTING I OAD ON CKT 24,AS REQUIRED.
SEE FLOOR PLANS FOR
LOCATIONS OF BLENDING UNITS
AND TIMER SWITCHES.
1\- 2#12NMB + G,
OR EQUAL
MP
ELECTRICAL ONE -LINE
NOT TO SCALE
FAMILY
ROOM
STUDY
LAUNDRY
LOWER FLOOR PLAN
1/4" = 1'
1sEDIROOM
3
ELECTRICAL LEGEND
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
G
UGHTING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
VLI
111111
4
DAMPER CONNECTION
D
NON-FUSED DISCONNECT SWITCH
o
MAST, WEAINERHEAD
❑S'
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
®D
SMOKE DETECTOR
ELECTRICAL METER
1
'TIMER OPERATED SWITCH
11
AERIAL SERVICE CONDUCTORS, COORDINATE WI1H U11UTY.
pT
THERMOSTAT
— - —
4E
CEIUNG MOUNTED FIRE ALARM -VISUAL STROBE UGHT
®
UNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN
5:00 PM.
ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH
INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
CI PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE.
0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY
CEILING OR WALL PENETRATION WORK.
NORTH
KITCHEN
LIVING
ROOM
DINING
ROOM
U
CL.
n
BEDROOM
1
22" x 30" EXIST.
ATTIC ACCESS
PANEL
MAIN FLOOR PLAN
1/4" = 1'
BATT -1
BEDROOM
2
9
RECEIVED
CITY OF TUKWILA
JUN 052013
■
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
■NSINIIRB. INC
XIII MOWN m. Meter. XOIM MX
TAMA. WA MIMn.
TilIpIO rM.411IWO
WO MM VM MIM
0810.03.2324
O
a.
-J
z
0
z
H
z
z
0
0
Z
(1)
z
w
w
0
a.
>
0
w
w
w
0
z
u_
U
121
AIP NUMBER
5-53-0058-045
DATE
SEPT 17, 2012
ISSUED
95%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
BCR
FLOOR
PLANS
NOTES
E1.0
0810.03.2324