Loading...
HomeMy WebLinkAboutPermit D13-199 - LYNCH RESIDENCE - TENANT IMPROVEMENTLYNCH RESIDENCE 10710 49 AV S D13-199 Parcel No.: Address: Suite No: Project Name: City oikukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov 5476800132 1071049AVSTUKW LYNCH RESIDENCE • DEVELOPMENT PERMIT Permit Number: Issue Date: Permit Expires On: D13-199 06/21/2013 12/18/2013 Owner: Name: Address: LYNCH MARTHA+JAMES 10710 49TH AVES , TUKWII,A WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: BLACK'S CARPENTRY INC Address: 14235 MAPLE VALLEY HY , RENTON WA 98058 Contractor License No: BLACKCI915RG Lender: Name: Address: Phone: • 206 296-7437 Phone: 206 713-8920 Expiration Date: 12/07/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS .AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINT AND STRUCTURE INCLUDING SOUND INSULATION AS WELL AS WINDOWS, DOORS, INSULATION, AND ABATEMENT. Value of Construction: $32,054.00 Type of Fire Protection: NONE Type of Construction: VB Electrical Service Provided by: SEATTLE CITY LIGHT Fees Collected: International Building Code Edition: Occupancy per IBC: $1,165.85 2009 0022 **continued on next page** doc: IBC -7/10 D13-199 Printed: 06-21-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: N Number: 0 Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Storm Drainage: Street Use: Profit: N Water Main Extension: Private: Water Meter: Permit Center Authorized Signature: N S Date: Public: Non -Profit: N Public: I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie hether specified herein or not. The granting of this permit does not pr e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: / p / Date: le/ ///3 Print Name: LC /.S7n o1 C,'07 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). doc: IBC -7/10 D13-199 Printed: 06-21-2013 7: VALIDITY OF PERMIT: The issuance or gr g of a permit shall not be construed to be a t for, or an approval of, any violation of any of the provisions of the ng code or of any other ordinances of the C f Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D13-199 Printed: 06-21-2013 CITY OF TUKWIL. Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwci.tukwila.wa.us Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. Pim (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 5476800132 Site Address: 10710 49th Ave. S. Tenant Name: Martha and James Lynch Suite Number: Property Owners Name: Martha and James Lynch Mailing Address: 10710 49th Ave. S. Floor: New Tenant: 0 Yes ® ..No Tukwila WA 98178 City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296-7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker@kingcounty.gov City State Fax Number: (206) 269-7315 Zip GENERAL CONTRACTOR INFORMATION -- (Contractor (Contractor Information for Mechanical (pg 4) for P1lumbing and Gas Piping (pg 5)) P91/1 0 14 t-tsl Company Name: not yet awarded Q \ VW S CMr1 l(/V, Mailing Address: City Contact Person: Day Telephone: Fax Number: Expiration Date: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Jesse Holgate or Timothy Fenlason E -Mail Address: Jesse@smstemper.comltfenlason@jonespayne.cq City State Day Telephone: (206) 624-2777 Fax Number: (206) 624-2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H:\Apphcations\Forms-Applications On Line\2009 Applications \1-2009 - Permit Appl cation.doc Revised: 1-2009 hh city Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT INFO ION — 206-431-3670 • Valuation of Project (contractor's bid price): $ 32,054 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? 0 Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 1,120 2nd Floor 3rd Floor Floors thru Basement 1,120 Accessory Structure* Attached Garage Detached Garage t Attached Carport f Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR • IZ ! ENT: Signature: Date: `i cr 10 (0 Print Name: Tim• y J. FenI. % SM Stemper Architects, PLLC Day Telephone: (206) 624-2777 Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 City State Zip Date Application Accepted: a„ [051 15 Date Application Expires: 1 21 Js (3 Staff Initials: H:Wpplications\Forms-Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised: 1-2009 bh Page 6 of 6 PLUMBING AND GAS PIPINRMIT INFORMATION 206-43 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'I Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping ousts bein:. stalled and the quantity below: Fixture Type: Qty Fixture Type: 1 . Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) ood-waste grinder, mercial Floor Drain Shower, single head trap Lavatory W. fountain Receptor, indirect waste Sinks Urinals Water ► 'set Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater a ' i /or vent Industrial to treatment interceptor, in ding trap and vent, excep or kitchen type grease interc4 ors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen (>750 gallon capacity) Repair i alteration of water r s ing and/or water treats -nt equipment Repair or alteration k drainage or vent pipin s Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 B kflow protective vice other than .tmospheric-type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow srotection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:\Applications\Forms-Applications On-Line\2009 Applications\I-2009 Permit Application.doc Revised: 1-2009 bh Page 5 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 5476800132 Address: 10710 49 AV S TUKW Suite No: Applicant: LYNCH RESIDENCE RECEIPT Permit Number: D13-199 Status: PENDING Applied Date: 06/05/2013 Issue Date: Receipt No.: R13-01829 Payment Amount: $1,165.85 Initials: JEM Payment Date: 06/06/2013 12:31 PM User ID: 1165 Balance: $0.00 Payee: PAMELA KUEHL WITH KING COUNTY (OVER THE PHONE) TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 051115 ACCOUNT ITEM LIST: Description 1,165.85 Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $1,165.85 703.85 457.50 4.50 Prinforl• na_na_/n1s INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ;rte, (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: /_ A \ JZ> .1. Type Inspection: r: )1/41,4--( D t . (O,'iG Addres r] , s p L Date Called: Special Instructions: / / Date Wanted ~2./ � 1m7 'I' P. m. Requester:. Phone No: 6 Approved per applicable codes. Corrections required prior to approval. COMMENTS: /S(:)) Insp / \ i t Dater?— It REINSPECTION FEE REQIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD CON PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-199 DATE: 06/05/13 PROJECT NAME: LYNCH RESIDENdE SITE ADDRESS: 10710 49 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS:' ;IN OUV c.(3 ID9lain Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 17:1 Incomplete ❑ DUE DATE: 06/06/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 07/04/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Per Friendly Page General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name BLACKS CARPENTRY INCORPORATED UBI No. 602058636 Phone 2067138920 Status Active Address 14235 Maple Valley Highway License No. BLACKCI915RG Suite/Apt. License Type Construction Contractor City Renton Effective Date 12/7/2009 State WA Expiration Date 12/7/2013 Zip 98058 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status BLACKCI004N1 BLACKS CARPENTRY INCORPORATED Construction Contractor General Unused 8/21/2000 9/20/2002 Archived Business Owner Information Name Role Effective Date Expiration Date BLACK, LAWRENCE President 12/07/2009 Amount GREGORY, LELAND WARD Secretary 12/07/2009 77 -NPP -4- 029885 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SI4617 11/16/2009 Until Cancelled $12,000.00 12/07/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 Nevada Capital Ins Co 77 -NPP -4- 029885 11/16/2012 11/12/2013 $1,000,000.00 11/08/2012 Contractors 1 Bonding a C11S14617 11/16/2009 11/16/2012 $1,000,000.0010/13/2011 Insuranc Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period httns://fortress.wa.gov/lni/bbin/Print.asnx 06/21/2013 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00782C12 BID PACKAGE S-35 3-53-0058-045 FILE COPY Permit No....tajaLai• Phan review approval Is sublectto errors end omissions. Approval of construction documents �. Receipt authorize the vio4a�on of any adopted � acknowledged: Ini approved Field Copy a Dam tlty Of'Nkwila BUILDING DIVISION SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND SPECIFICATIONS INCLUDING BUT NOT LIMITED TO: APPLICABLE YES NO L SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL -FRAMED ACOUSTICAL WINDOWS. X 2. CUT DOWN OF WINDOWS TO COMPLY UJITH EGRESS REQUIREMENTS. X 3. INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X 8. INSTALLATION OF PET DOORS. X 9. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 10. INSTALLATION OF CHIMNEY CAP. X 11. REGULATED MATERIALS ABATEMENT. X 12. ATTIC VENT BAFFLES. X 13, INSTALLATION OF ATTIC INSULATION. X 14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 18. INSTALLATION OF SMOKE DETECTORS. X 19. NEW ELECTRICAL PANEL / SERVICE. X 20. KNOB AND TUBE WIRING. X SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may in;.Iude additional plan review fees. SITE AND BUILDING INFORMATION S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 JURISDICTION: Department or Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, international Mechanical Code 5416800132 ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) v B NON SPRINKLERED LEGAL DESCRIPTION: THE SOUTH 62 FEET OF THE NORTH 153 FEET OF THAT PORTION OF TRACT 15, MERRICKS ACRE TRACTS DIVISION NO. 2 ADDITION TO THE CiTY OF SEATTLE, ACCORDING TO PLAT RECORDED IN VOLUME 12 OF PLATS, PAGE 41, IN KING COUNTY, WASHINGTON, LYING SOUTH OF SOUTH 101th STREET AS CONDEMNED INKING COUNTY SUPERIOR COURT CAUSE NO. 191022, EXCEPT ANY PORTION CONDEMNED FOR 49th AVENUE SOUTH IN KING COUNTY SUPERIOR COURT CAUSE NUMBER 191022 AND 266632. REVIEWED FOR CODE COMPLIA VCE APPROVED JUN 21 2013 BUILp N f' DRAWING INDEX T0.0 TITLE SHEET, PROJECT INFO. 41.0 FLOOR PLANS 4 NOTES .41.1 FLOOR PLANS 4 NOTES 42.0 WINDOW TYPES, SCHEDULE 4 DETAILS A2.1 DOOR TYPES, SCHEDULE 4 DETAILS 422 MISCELLANEOUS DETAILS 42.3 WINDOW FLASHING DETAILS MI.0 LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DUJG INDEX M2.0 MECHANICAL PLANS AND DETAILS E1.0 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206. 296. 0190 Contact: Sharyn Parker E-mail: Sharyn.Parker*kingcounty.gov ARCHITECT: S.M. Stemper Architects P.L.L.C. 4000 Delridge Way SUJ, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax; 206. 624. 2913 Contact: Jerry Osborn, Melody Leung E-mail: jerryssmstemper.com melody msmstemper.com ACOUSTICAL ENGINEER: 554 Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 539. 0819 Fax: 206. 839. 0824 Contact: Mohamed Alt. Allaoua E -ma i l: mohamedessaacoustics.com MECI4ANiCAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph: 206. 318. 0569 Fax: 206. 318. 0641 Contact: Dylan Turner E-mail: DylanTsgreenbusch.com ELECTRICAL ENGINEER: Tres West Engineers 2102 5. 42nd Street, Suite 301 Tacoma, UJA 98409 Ph: 253. 412. 3300 Fax: 253. 412. 3463 Contact: Brent Rollins E-mail: bcrstreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206. 162. 41180 Contact: Tim Ogden E-mail: tim ogdenspbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123, North Washington 5t. *200 Boston, MA 02114 Contact: Tim Fenlason, Cynthia Maeda E-mail: trenlasonmjonespayne.com CMa eda ejonespayne.com STRUCTURAL ENGINEER Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206. 622. 4580 Fax: 206. 622. 0422 Contact: Ron Martinson E-mail: ronmmpsm-engineers.com RECEIVED CITY OF TUKWILA VICINITY MAP (NTS) JUN 052013 PERM i UtN I ER Int ViSiON 4220 REGISTERED A HI'i'ECJ SCOTT WTEMPEZ STATE 0= I SHINGTON' OCTOBER 19, 2012 0810.03.2324 0 z 0 z w z z 0 0 0 z MPROVEMENTS >- 0 w w Lu 0 1-1z I_I_ 0 Lu � r AIP NUMBER 3-53-0058-045 0 F - DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP PROJECT INFORMATION, DRAWING INDEX, DIRECTORY T0.0 0810.03.2324 SPECIAL NOTES: L LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 II 01 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. 2. REFERENCE S/A22 FOR SMOKE/ CARBON MONOXIDE DETECTOR INSTALLATION DETAIL. FAMILY ROOM STUDY LAUNDRY (E) FIREPLACE INSERT GENERAL NOTES I. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOUJI`IERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, MD REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 9:00 AM AND 5:00 PM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH. AS CLOSELY AS POSSIBLE TO EX15TING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY -ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 15. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. I. CONTRACTOR 15 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 411. 4 AFTER 5:00 PM. BATH / BEDROOM 3 LOWER FLOOR PLAN 1/4"=1'-0" A. WEST ELEVATION KITCI-1EN (E) FIREPLACE INSERT LIVING ROOM B. NORTH ELEVATION PLAN KEYNOTES ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. O DEMOLISH EXISTING DOOR(6), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, 2 STORM DOOR REF. DOOR SCHEDULE. OCOORDINATE CEILING GRILL WITH MECHANICAL DOCUMENTS. O COORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. DETAIL. DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/,42.2 FOR O MECHANICAL DOCUMENTS. O BLENDING UNIT LOCATED AND INSTALLED IN SOFFIT WITH 16"XI6" ACCESS HATCH, REF. MECH. DOCUMENTS FOR DOCUMENTS FOR SPEED CONTROL AND DISCONNECT. REF. 3/422 FOR DETAIL. O INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE WITH MECHANICAL ELECTRICAL DOCUMENTS. O DEMOLISH WALL FINISH UNDER (E) WINDOW SILL TO INSTALL NEW 4X4 POST. INSTALL NEW POST AND PATCH ADJACENT FINISH. DEMOLISH (E) WINDOW, CASING AND TRIM. SPLIT (E) OPENING AND INSTALL (2) ACOUSTICAL AND I) REF. WINDOW SCHEDULE ANP 1/422 FOR PETAL. ,.»: .. ..M -,4 4... u. f.• V. •i 1 -,'•• ..... v,..',.1:. • vo•'t ..*.44.01-,;." ....... . ........_. ..-......»..... CASING, TRIM, THRESHOLD AND REF. MECH. FOR INSTALLATION DETAIL. COORDINATE WITH UNIT, REF. ELECT. AND WALL TO MATCH WINDOWS (H .r• . . K... .r. ..1.-'..S.A. . .. .. •• - I , .,( 4 •i•,,'`4.7` teite,.1911 ,,,,;..1.. l... 1i . t-,;." , ('• ff i. ; •,. ,.„.ar.ar.r h++1lM W+Mn..w.w•r.....' ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. DINING ROOM 1- LU 0 O U BEDROOM 22" x 30" EXIST. ATTIC ACCESS PANEL —W- 422 A MAIN FLOOR PLAN 1/4" = 1' - 0" C. EAST ELEVATION LEGEND A ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR/ STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW BATH BEDROOM 2 D REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 052013 PERMIT CENTER D. SOUTH ELEVATION GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 r------ ATTIC INSULATION ATTIC INSULATION DAM SD INSTALL BATTERY OPERATED SMOKE DETECTORS SG INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS ISAS GAS METER SOFFIT FOR MECHANICAL DUCTING S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 4220 REGISTERED A;CHITECT COTT liTEMPE' STATE OF •SHINGTON OCTOBER 19, 2012 0810.03.2324 0 a. J z 0 z Ct w z > z 0 0 z MPROVEMENTS >- 0 w w w 0 z LL U J z w 0 (1) w AIP NUMBER 3-53-0058-045 DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES A1.0 0810.032324 SPECIAL NOTES: 1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 11 01 AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. 2. REFERENCE 5/422 FOR SMOKE/ CARBON MONOXIDE DETECTOR INSTALLATION DETAIL. GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES 45 REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 5:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. B. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11. ALL WORK AREAS SHALL BE BROOM -GLEANED AT TI -4E END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS ANp/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY TI -IE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS 51-IALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK. REFER TO ELECTRICAL FOR TIMER LOCATION 18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. 19. CONTRACTOR 15 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20, MAXIMUM POWER OUTAGE IS EIGHT HOURS. POUTER MUST BE PROVIDED AT RESIDENCE BEFORE S:00 AM. 4 AFTER 5:00 PM. • L n U J l 22" x 30" EXIST. ATTIC ACCESS PANEL J P r —J L L 26'-1" 1 1 .................. 1 14'-6" A. WEST ELEVATION ATTIC PLAN 114"=1'-O" B. NORTH ELEVATION PLAN KEYNOTES ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. DEMOLISH EXISTING DOOR(S), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND O STORM DOOR REF. DOOR SCHEDULE. OCOORDINATE CEILING GRILL WITH MECHANICAL DOCUMENTS. O COORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION DETAIL. DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/42.2 FOR DETAIL. COORDINATE WITH O MECHANICAL DOCUMENTS. O BLENDING UNIT LOCATED AND INSTALLED IN SOFFIT WITH 16"X16" ACCESS HATCH, REF. MECH. DOCUMENTS FOR UNIT, REF. ELECT. DOCUMENTS FOR SPEED CONTROL AND DISCONNECT. REF. 3/422 FOR DETAIL. O INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE WITH MECHANICAL AND - ELECTRICAL DOCUMENTS. O DEMOLISH WALL FINISH UNDER (E) WINDOW SILL TO INSTALL NEW 4X4 POST. INSTALL NEW POST AND PATCH WALL TO MATCH ADJACENT FINISH. DEMOLISH (E) WINDOW, CASING AND TRIM. SPLIT (E) OPENING AND INSTALL (2) ACOUSTICAL WINDOWS (H AND I) REF. WINDOW SCHEDULE AND 1/422 FOR DETAIL. 1 i` t , t , l 4 1 ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. C. EAST ELEVATION J REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 052013 PERMIT CENTER LEGEND r A ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR/ STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW D. SOUTH ELEVATION bi°6-14/7 1111111111111 c GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 r----- ATTIC INSULATION ATTIC INSULATION DAM SD INSTALL BATTERY OPERATED SMOKE DETECTORS SC INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS 15,45GAS METER SOFFIT FOR MECHANICAL DUCTING j S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 4220 REGISTERED ALHITECT COTT TEMPE STATE OR SHINGTON OCTOBER 19, 2012 0810.03.2324 NTERNATIONAL AIRPORT KING COUNTY z w w 0 0 w Nw 1t w 0 z 1 - LL OL 0 Ct Q 1--- 0 0 (1) w OL AIP NUMBER 3-53-0058-045 z 0 F— DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS NOTES A1 .1 0810.03.2324 WINDOW TYPES 1. FIXED 2. HORIZONTAL XX SLIDER G 3. FIXED OVER SLIDER/ FIXED/ SLIDER (SLIDER MAY BE INSTALLED ON TOP) WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS DETAIL SET A ENTRY 1 4'-5" x 3'-11" STAIN/STAIN SAFETY GLAZING REQUIRED, RAISE (E) SILL HEIGHT FOR FRAMING, REF. 6/42.2 FOR DETAIL 1/42.0 B ENTRY I I'-6" x 6'-8" STAIN/STAIN SAFETY GLAZING REQUIRED, OBSCURE GLASS SHRINK WINDOW WIDTH FOR FRAMING, REF. 6/42.2 FOR DETAIL 2/42.0 C LIVING ROOM 3 10'-0" x 4'-10" STAIN/STAIN SAFETY GLAZING REQUIRED, REMOVE 4 REINSTALL (E) SHUTTERS 3/42.0 D KITCHEN 2 5'-11" x 2'-11" STAIN/STAIN TYP AT HEAD AND JAMBS. 3/A2.0 E KITCHEN 2 2'-11" x 2'-10" STAIN/STAIN SAFETY GLAZING REQUIRED 3/42.0 F BEDROOM 1 2 1'-11" x 2'-11" STAIN/STAIN SAFETY GLAZING REQUIRED 3/42.0 G BEDROOM 2 2 T-11" x 2'-11" STAN/STAIN .1 3/A2.0 H FAMILY ROOM 2 4'-10" x 2'-4" STAIN/STAIN SAFETY GLAZING REQUIRED, REMOVE 4 REINSTALL (E) SHUTTERS 3/A2.0 I FAMILY ROOM 2 4'-10" x 2'-4" STAIN/STAIN SAFETY GLAZING REQUIRED, REMOVE 4 REINSTALL (E) SHUTTERS 3/42.0 J FAMILY ROOM 2 4'-11" x 2'-5" STAIN/STAIN SAFETY GLAZING REQUIRED 3/A2.0 K BEDROOM 3 2 1'-11" x 2'-5" STAIN/STAIN SAFETY GLAZING REQUIRED, REMOVE 4 REINSTALL (E) SHUTTERS 3/A2.0 TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET. SLOPE E I" min. 1/Z." min. I I HEMMED EDGE J END CLOSURE C-10 HEAD FLASHING DETAIL TYP. " REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2013 City of Tukwila BUILDING DIVISION rifect RECEIVED CITY OF TUKWILA JUN 052013 PERMIT CENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 REGISTERED 1\, [ECT ../SCOTT+ °TEMIPE. • STATE 0=) SHINGTON''' OCTOBER 19, 2012 0810.03.2324 0 0 J z 0 z w z z 0 U z AIP NUMBER MPROVEMENTS >- 0 cw w w 0 z LL L1.1 3-53-0058-045 z 0 Q DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2324 I I III (E) WD. SIDING (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT \ J (E) GWB CAREFULLY LIFT (E) WALL UNDERLAYMENT J lEJ GWB AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION ) AND INSTALL SELF -ADHERING MEMBRANE\ PENETRATION FLASHING. LAP (E) WALL f (E) WALL UNDERLAYMENT ACOUSTICAL WINDOW ASSEMBLY - P P TYP AT HEAD AND JAMBS. �li �,FLASHING. (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING UNDERLAYMENT OVER PENETRATION TYP AT HEAD AND JAMBS. i I(E) I(E) _ C -_______------)FLASHING. WALL UNDERLAYMENT .1 REMOVE (E) WOOD SIDING FOR 1 - REMOVE (E) WOOD SIDING FOR 1 I '�J EXTERIOR SHEATHING a INSTALLATION OF NEW WINDOW SELF ADHERING ASSEMBLY AND TRIM. REPLACE OR RE - 1 ( / ��7 MEMBRANE TRIM- MATCH (E) TRIM. PRIME ALL r INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE 111MEMBRANE --- SELF ADHERING SIDES AND PAINT TO MATCH (E) TRIM. ► NEW 2"X STUD FRAMING INSTALL SIDING AS REQ'D. MAINTAIN `r j COLOR TO BE FIELD DETERMINED I (E) COURSING. PAINT MODIFIED SIDING I I TOUCH UP PAINT, AS REQ'D f INSTALL SIDING AS REQ D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING 11 I ) TOUCH UP PAINT, AS REQ'D i 1 I TO MATCH (E) SIDING. 1101 I I I ) CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM TO MATCH (E) SIDING. I CONTINUOUS PRE -PRIMED, GALY SHEET METAL 1 I ` SEALANT, TYP. O L � PRE -PRIMED, GALY SHEET METAL - FLASHING W/ CLOSURE UNDER ,� %> I I \ 1 FLASHING UNDER SELF -ADHERING , %/ / I I END m I� SOLID WOOD TRIM SELF -ADHERING MEMBRANE. COLOR t0 i - COLOR TO BE SELECTED IN - 10 SOLID WOOD TRIM _ • UD JAMB LINING BE SELECTED IN THE FIELD a � �� , _ _MEMBRANE. SEALANT THE FIELD a _ L_� - TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED - I�I LI !tet WD. JAMB LINING ll lr �_� TRIM- MATCH (EJ TRIM. PRIME ALL •I WD. JAMB LINING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED 0 , lr SEALANT WINDOW REMOVE (E) WD. SIDING FOR HEAD/ I SILL AT SIDE LIGHT SEALANT BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY II II II SHIM AS NECESSARY FILL GAP W/ BATT BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY II II II II SHIM AS NECESSARY FILL G AP UJ/ BATT REMOVE (E) WD. SIDING FOR WINDOW HEAD INSULATION WINDOW REMOVE (E) WD. SIDING FOR HEAD INSULATION INSTALLATION OF NEW WINDOW TRIMS AND REATTACHMENT OF (E) SIDING TO WINDOW OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL/ WINDOW / NAILING FLANGE OVER SELF 1 (E) GWBWALL INSTALLATION OF NEW WINDOW TRIMS AND REATTACHMENT OF (E) SIDING TO WINDOW OPENING FRAMING. LIFT (E) UNDERLAYMENT AND INSTALL (E) GWB INSTALLATION OF NEW WINDOW TRIMS REATTACHMENT OF (E) SIDING TO WINDOW OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL (E) GUS ADHERING MEMBRANE PENETRATION - WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION ----..j WINDOW /NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION ll (I �J FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER '- I I �� FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER II jl TOUCH UP PAINT, A5 REQ1D NAILING FLANGE AND LAP UNDER (E) II TOUCH UP PAINT,A5 REQ'D FLASHING. INSTALL SECOND LAYER OF >- SELF ADHERING MEMBRANE OVER �- NAILING FLANGE AND LAP UNDER (EJ i II TOUCH UP PAINT, AS REQ D WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. MODIFIED SIDING CONTINUOUS SEALANT, TYP. NAILING FLANGE AND LAP UNDER (E) CONTINUOUS WALL UNDERLAYMENT. CAULK NEW SEALANT, TYP. WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL 1 I CONTINUOUS SEALANT, TYP. AV VERTICAL SIDING JOINTS 4 SET NAIL PAINT SOLID WOOD TRIM TO MATCH (E) SIDING phi \ HEADS FLUSH. MODIFIED SIDING PAINT SOLID WOOD TRIM HEADS FLUSH. PAINT MODIFIED SIDING \ SOLID WOOD TRIM (E) WD. SIDING ` TO MATCH lEJ SIDING II 1 \ - `^ TO MATCH (E) SIDING I \? - a ` (E) WD. SIDING Ol -- (E) WALL UNDERLAYMENT _ a 11[1:1 \\ \ WD JAMB LINING "' Q PH N - lE) EXTERIOR SHEATHING SEALANT (E) WALL UNDERLAYMENT �1 WD JAMB LINING (E) WALL UNDERLAYMENT WD JAMB LINING (E) EXTERIOR SHEATHING _ SEALANT �l (E) EXTERIOR SHEATHING - -� SEALANT BACKER ROD 4 SEALANT SHIM AS NECESSARY FILL GAP W/ BATT 1�t _ 4 SEALANT 1®_ ISI ISI BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY II II ll II SHIM AS NECESSARY FILL GAP W/ BATT ACOUSTICAL WINDOW ASSEMBLY WINDOW II II III II II JAMB III INSULATION BACKER ROD ACOUSTICAL WINDOW ASSEMBLY r SHIM A5 NECESSARY FILL GAP W/ BATT WINDOW I III JAMB INSULATION WINDOW JAMB II II " , �J i & = III II I"�I DOOR II �J INSULATION JAMB ACOUSTICAL WINDOW ASSEMBLY ''--- H 0 III 0 BACKER ROD 4 SEALANT" 3/4" ACOUSTICAL WINDOW BACKER ROD 4 SEALANT 3/4" WOOD SILL ASSEMBLY MI ACOUSTICAL WINDOW /6 1 '' N' \ ASSEMBLY SHIM AS NECESSARY - P PI SEALANT 4 BACKER ROD EXISTING FLOOR WINDOW NAILING FIN -� I& j 1 FILL GAP W/ BATT INSULATION Il CONTINUOUS SEALANT BEHIND Z BAR FRAME \ \ \ (E) W WOOD 2X STRUCTURE /� l 1 SOLID WOOD TRIM _ 4 SEALANT ` TRIM- MATCH (E) TRIM. PRIME ALL 1 , STORM DOOR PER SCHEDULE ' ` ' 'Tr ` SOLID WOOD TRIM SIDES AND PAINT TO MATCH (E) TRIM. BACKER ROD COLOR TO BE FIELD DETERMINED • - A • SILL PAN i�l-t • , NTINUOUS SEALANT, TYP. PRE -PRIMED GALV. FLASHING- LAP JAMB FLASHING INTO SILL PAN. EMBED LAP IN SEALANT. FIELD PAINT FLASHING - COLOR TO BE SELECTED IN THE FIELD WOOD SIDING CWOOD WINDOW SILL - WINDOW DETAIL SET KERF AS SHIM A5 NECESSARY FILL GAP W/ BATT REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE TOUCH UP PAINT, AS REQ'D REQUIRED FOR WEATHER INSULATION STRIPPING INSTALLATION I 2" MIN. INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) EXTERIOR SHEATHING SELF MEMBRANE II DOOR PER SCHEDULE CONTINUOUS WEATHER-STRIPPING WINDOW SILL & DOOR HEAD -------) (E) GLIB (E) WD SIDING WINDOW SIDING - SILL WINDOW 1) I ...... DETAIL SET WOOD SIDING - WINDOW DETAIL SET 3"=1'-0" 3"=1'-0" C3) 311= 1' - 01l REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2013 City of Tukwila BUILDING DIVISION rifect RECEIVED CITY OF TUKWILA JUN 052013 PERMIT CENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 REGISTERED 1\, [ECT ../SCOTT+ °TEMIPE. • STATE 0=) SHINGTON''' OCTOBER 19, 2012 0810.03.2324 0 0 J z 0 z w z z 0 U z AIP NUMBER MPROVEMENTS >- 0 cw w w 0 z LL L1.1 3-53-0058-045 z 0 Q DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2324 DOOR TYPES 7 i N/ A FLUSH SCUD HALF -LITE 1U/ 2 PANELS UJ/ SAFETY GLAZING B FLUSH SCW DBL. LEAF HALF -LITE W/ 2 PANELS UJ/ SAFETY GLAZING C FLUSH SCUD 3 LITES, 3 PANELS W/ SAFETY GLAZING UJ/ OBSERVATION PORT EXTERIOR SINGLE LEAF STORM UJ/ FULL -LITE SAFETY GLAZING EXTERIOR SINGLE LEAF STORM UJ/ FULL -LITE SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 ENTRY C 3'-0 x 6'-8" STAIN/ STAIN 1-1111-1 / 626 OK -4 LOCK -1 I/A2.1 2 KITCHEN A 2'-8" x 6'-8" STAIN/ STAIN HUJ-1 / 626 DK -3 LOCK -1 2/A2.1 3 DINING ROOM (DBL. LEAF) B 4'-10" x 6'-8" STAIN/ STAIN HUJ-1 / 626 DK -3 LOCK -1 2/A2.1 4 ENTRY D 3'-0 x 6'-8" I/42.1 5 KITCHEN D 2'-8" x 6'-8" 2/A2.1 6 DINING ROOM (DBL. LEAF) E 4'-10" x 6'-8" 2/A2.1 TYPICAL DOOR SCHEDULE NOTES 1. 2. 3. 4. 5. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 8000, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET. 1" min. 1/2." min. HEMMED EDGE SLOPE END CLOSURE HEAD FLASHING DETAIL TYP. 3"=1'-0" ACOUSTICAL WINDOW ASSEMBLY CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM POOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER-STRIPPING (E) WOOD 2X STRUCTURE 2" MIN. SOLID WOOD TRIM 51-1IM AS NECESSARY PILL GAP W/ BATT INSULAT ION DOOR PER SCHEDULE DOOR HEAD & WINDOW SILL/ JAMB (SIM) REMOVE (E) WD. SIDING FOR INSTALLATION OF NEW DOOR TRIMS AND REATTACHMENT OF (E) SIDING TO DOOR OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) WOOD SIDING CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE (E) EXTERIOR SHEATHING TOUCH UP PAINT, AS REQ'D CONTINUOUS KERF A5 REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER-STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE SILL IN HEAD OF SEALANT DOOR JAMB DOOR SILL SEALANT, TYP. EXISTING FRAMING SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP UJ/ BATT INSULATION DOOR PER SCI-IEDULE WOOD SIDING - DOOR DETAIL SET 3"=1'-0" (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW DOOR ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. PRE -PRIMED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. (E) EXTERIOR SHEATHING SELF -ADHERING MEMBRANE TOUCH UP PAINT AS, REQ'D CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM 514IM A5 NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF A5 REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE REMOVE (E) UJD. SIDING FOR INSTALLATION OF NEW DOOR TRIMS AND REATTACHMENT OF (E) SIDING TO DOOR OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PANT MODIFIED SIDING TO MATCH (E) SIDING (E) WOOD SIDING CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF A5 REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER-STRIPPING JAMB BEYOND DOOR HEAD "_") (E) EXTERIOR SHEATHING TOUCH UP PAINT, A5 REQ'D CONTINUOUS DOOR JAMB WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE SILL IN HEAD OF SEALANT DOOR SILL SEALANT, TYP. EXISTING FRAMING SOLID U)OOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE WOOD SIDING - DOOR DETAIL SET 3"=1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 052013 PERMIT CENTER S.M.STEMPEP ARCHITE CTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 08106 (206) 624-2777 • FAX (206) 624-2973 REGISTERED •AqHIIEC'f COTT TEMP-' STATE OF ! HINGTON` OCTOBER 19, 2012 0810.03.2324 MPROVEMENTS >- 0 w w cc w 0 z U ccQ J Q H Z W D W AIP NUMBER 3-53-0058-045 z 0 1- z_ Cn DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.2324 CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF VENT FIXTURE AND FLASHING. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. PRE -PRIMED, GALV. SHEET METAL FLASHING W/ F.F. END CAPS UNDER SELF -ADHERING MEMBRANE. EXTEND FLASHING 4" UP WALL. PAINT COLOR TO BE SELECTED IN TIE FIELD PAINT VENTILATION HOOD, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION HOOD. REF. MECH- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. (E) WALL UNDERLAYMENT SELF -ADHERING MEMBRANE (E) EXTERIOR SHEATHING 2X BLOCKING 2X2 CONTINUOUS PRESSURE TREATED BLOCKING, 4 SIDES REMOVE / REPLACE (E) SIDING AS REQUIRED. (E) HEADER WINDOW ASSEMBLY PER SCHEDULE (E) 2x FRAMING NEW 4x4 HEADER DOOR PER SCHEDULE AIR INTAKE DETAIL AT EXTERIOR 3"= 1'-0" 2X BLOCKING u NEW DOUBLE 2x6 NEW 2x TRIM STUDS WINDOW ASSEMBLY PER SCHEDULE FRAMING ANCHOR AT FLOOR, REQ'D NOTE: FIELD VERIFY ALL DIMENSIONS FRAMING DETAIL AT FRONT DOOR (INTERIOR) 1 = 1 -0 (E) HEADER WINDOW ASS PER SCHEDI (2) NEW OR (! TO SUPPORT HEADER. EA. NEW 4X4 PO W/ SIMPSON EACH SIDE T BOTTOM (E) 2x CRIPPLE ST 16" O.C. NOTE: FIELD ALL DIMENS EXISTING ROOF (E) ROOF FRAMING (E) EAYE VENT. MAY VERY AT EACH PROPERTY. 51-01L IN CELLULOSE INSULATION WITH A COMBINED VALUE OF NOT LESS THAN R-38 INSULATION DAM (E) WALL FRAMING VERT. CHASE WALL 2x4 FRAMING DUCT PER MECH. WD BASE- PAINT TO MATCH (E) WALLS TRIM FINISH FLOOR AND UNDERLAYMENT TO F.O. (E) WALL. BUTT %" TYPE X GYP TIGHT TO SUBFLR. (E) FLOOR FRAMI (E) GWB DUCT CHASE NEW GRILL COORDINATE WITH MECHANICAL VERTICAL CHASE DETAIL HOLD MINIMUM, BUT A5 REQUIRED TO COORDINATE DUCT UJ/ (E) FLOOR AND CEILING FRAMING. DEMOLISH (E) FLOOR (E) FINISH FLOOR DEMOLISH (E) GWB (E) FLOOR CONSTRUCTION FINISH FLOOR %" CPX PLYWOOD 2x10 016" O.C. " GWB 1 1/2" = 1' - 0" FRAMING DETAIL AT WINDOW H (INTERIOR) • EXISTING CEILING STRUCTURE 1 1111111111111 ,1 CEILING MOUNTING BRACKET IJ" X 1Y" ANGLE IRON LEG BOLTED TO (E) STRUCTURE WOOD (E) EXTERIOR WALL FRAMING DUCT PER MECH. UJ/ IN SOFFIT 1x2 WD BASE- PAINT TO MATCH (E) WALLS TRIM FINISH FLOOR AND UNDERLAYMENT TO F.O. (E) WALL. BUTT 5/9" TYPE X GYP TIGHT TO SUBFLR MECH UNIT AND DUCTS - REF MECHANICAL HOLD TIGHT TO (E) CEILING STRUCTURE ABOVE CONTINUOUS VIBRATION DAMPENING PAD RE: MECHANICAL WHERE WIDTH OF SOFFIT EXCEEDS 16", INSTALL 2X4 STUDS m 16" O.C. BLENDING AIR UNIT DETAIL 5/8" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. 2x2 CONT. NAILER (E) CLOSET (E) GWB DUCT CHASE 16"X16" ACCESS HATCH FOR MAINTENANCE HOLD MINIMUM, BUT AS REQUIRED TO COORDINATE DUCT UJ/ (E) FLOOR AND CEILING FRAMING. RE -BUILD (E) CLOSET SHELVING AND ROD TO ACCOMMODATE CHASE (E) FINISH FLOOR NOTCH TOP PLATE AND TRIM STUDS OF PARTITION AS REQ'D TO ACCOMMODATE PASSAGE OF MECH. COMPONENTS. WALL PENETRATIONS SHALL BE CUT FULL SIZE OF SOFFIT AREA, TYPICAL ANCHOR CEILING NAILER TO (E) JOIST WHERE WIDTH OF SOFFIT EXCEEDS 16", PROVIDE 2X4 SOFFIT FRAMING m 16" O.G. PROVIDE FINISH -GRADE PAINTABLE GWB EDGE AND CAULK JOINT E 0 i— r - 5 (E) FLOOR CONSTRUCTION FINISH FLOOR %" CDX PLYWOOD 2x10*16"OC Y2" GWB 2x BLOCKING BETWEEN STUDS WHICH REQUIRE TRIMMING 2x2 CONT. NAILER 5/8" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. MOISTURE -RESISTANT GWB AT BATHROOM SOFFITS ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL CONTRACTOR AND FIELD CONDITIONS (E) WD FRAME WALL ASSEMBLY DUCT CHASE/ SOFFIT DETAIL 1 1/2" = 1' - 0" CEILING 4"MIN BEST HERE ACCEPTABLE HERE NOTE: REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. SIDE WALL REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2013 BUILDING TukwiIa DIVISION DETECTOR INSTALLATION DETAIL TYP. 3=1-0 RECEIVED CITY OF TUKWILA JUN 0 5 203 PERMIT CENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 REGISTERED ACHIIECT OOTT ETEMPE' STATE 07 '? ,oHINGT'ON OCTOBER 19, 2012 0810.03.2324 0 0_ J z O Lt w z z O 0 z AIP NUMBER MPROVEMENTS >- 0 cw w w O z LL U J 3-53-0058-045 z 0 I— DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP MISC. DETAILS A2.2 0810.03.2324 :MBLY LE E)2x NEW SIDE 51 %, /r / �',//,� // A34 OP AND L_ I--- DS AT VERIFY IONS 4 1 L FRAMING DETAIL AT WINDOW H (INTERIOR) • EXISTING CEILING STRUCTURE 1 1111111111111 ,1 CEILING MOUNTING BRACKET IJ" X 1Y" ANGLE IRON LEG BOLTED TO (E) STRUCTURE WOOD (E) EXTERIOR WALL FRAMING DUCT PER MECH. UJ/ IN SOFFIT 1x2 WD BASE- PAINT TO MATCH (E) WALLS TRIM FINISH FLOOR AND UNDERLAYMENT TO F.O. (E) WALL. BUTT 5/9" TYPE X GYP TIGHT TO SUBFLR MECH UNIT AND DUCTS - REF MECHANICAL HOLD TIGHT TO (E) CEILING STRUCTURE ABOVE CONTINUOUS VIBRATION DAMPENING PAD RE: MECHANICAL WHERE WIDTH OF SOFFIT EXCEEDS 16", INSTALL 2X4 STUDS m 16" O.C. BLENDING AIR UNIT DETAIL 5/8" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. 2x2 CONT. NAILER (E) CLOSET (E) GWB DUCT CHASE 16"X16" ACCESS HATCH FOR MAINTENANCE HOLD MINIMUM, BUT AS REQUIRED TO COORDINATE DUCT UJ/ (E) FLOOR AND CEILING FRAMING. RE -BUILD (E) CLOSET SHELVING AND ROD TO ACCOMMODATE CHASE (E) FINISH FLOOR NOTCH TOP PLATE AND TRIM STUDS OF PARTITION AS REQ'D TO ACCOMMODATE PASSAGE OF MECH. COMPONENTS. WALL PENETRATIONS SHALL BE CUT FULL SIZE OF SOFFIT AREA, TYPICAL ANCHOR CEILING NAILER TO (E) JOIST WHERE WIDTH OF SOFFIT EXCEEDS 16", PROVIDE 2X4 SOFFIT FRAMING m 16" O.G. PROVIDE FINISH -GRADE PAINTABLE GWB EDGE AND CAULK JOINT E 0 i— r - 5 (E) FLOOR CONSTRUCTION FINISH FLOOR %" CDX PLYWOOD 2x10*16"OC Y2" GWB 2x BLOCKING BETWEEN STUDS WHICH REQUIRE TRIMMING 2x2 CONT. NAILER 5/8" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. MOISTURE -RESISTANT GWB AT BATHROOM SOFFITS ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL CONTRACTOR AND FIELD CONDITIONS (E) WD FRAME WALL ASSEMBLY DUCT CHASE/ SOFFIT DETAIL 1 1/2" = 1' - 0" CEILING 4"MIN BEST HERE ACCEPTABLE HERE NOTE: REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. SIDE WALL REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2013 BUILDING TukwiIa DIVISION DETECTOR INSTALLATION DETAIL TYP. 3=1-0 RECEIVED CITY OF TUKWILA JUN 0 5 203 PERMIT CENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 REGISTERED ACHIIECT OOTT ETEMPE' STATE 07 '? ,oHINGT'ON OCTOBER 19, 2012 0810.03.2324 0 0_ J z O Lt w z z O 0 z AIP NUMBER MPROVEMENTS >- 0 cw w w O z LL U J 3-53-0058-045 z 0 I— DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP MISC. DETAILS A2.2 0810.03.2324 LIFT (E) WALL UNDERLAYMENT AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. LAP SILL MEMBRANE FLASHING 2-1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND 1 i" BEYOND RO. AT EA. END OF SILL. (E) WALL UNDERLAYMENT AT SILL 1 (E) SHEATHING GUT SILL FLASHING TO EDGE OF R.O. AS SHOWN. ADHERE MEMBRANE FLASHING t0 OUTSIDE FACE OF UJALL SHEATHING 1" MIN MEMBRANE FLASHING AT SILL 5 J 13UTTERFFLY CORNER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. \--,— (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT 514OULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) WALL UNDERLAYMENT AT SILL. MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES 4 WINDOW MEMBRANE INSTALLATION i SCALE: NTS REMOVED EDGE OF ( E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) UJALL UNDERLAYMENT BACK DOWN OVER FLANGE FLASHING AT JAMBS \7l BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. r WHERE REQUIRED, TRIM (E) WALL UNDERLAYMENT AT HEAD TO PREPARE FOR INSTALLATION OF HEAD FLA ING AND WINDOW TRI (FOLLOWI STEPS). L J HEAD FLASHING PREPARATION SCALE: NTS (E) WALL UNDERLAYMENT NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. (z) CUT JAMB FLASHING TO EDGE OF WINDOW OPENING AS SHOWN. EXTEND 1-1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASH ING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D (E) SIDING NOT SHOU,N FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. — INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. /5 MEMBRANE FLASHING AT JAMB SCALE: NTS INSTALL SHT. METAL HEAD FLASHING UNDER (E) BLDG PAPER. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW I/8" BETWEEN FL BOT. EDGE SIDING LEARANCE SHING AND (E) TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. HEAD FLASHING INSTALLATION SCALE: NTS (E) WALL UNDERLAYMENT 3� MEMBRANE FLASHING AT HEAD SCALE: NTS INSTALL HEAD CUT HEAD FLASHING TO EDGE OF WINDOW OPENING 45 SHOWN. EXTEND 1-1/2" BEYOND R.O. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF UJALL SHEATHING (TYP. EACH SIDE OF WALL) NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. FLANGE FLASHING OVER WINDOW NAILING FLANGE ANP FLASHING. C6 WINDOW FLASHING INSTALLATION SCALE: NTS o 0 0 0 0 0 1 1 MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES 4 WINDOW MEMBRANE INSTALLATION i SCALE: NTS REMOVED EDGE OF ( E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) UJALL UNDERLAYMENT BACK DOWN OVER FLANGE FLASHING AT JAMBS \7l BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. r WHERE REQUIRED, TRIM (E) WALL UNDERLAYMENT AT HEAD TO PREPARE FOR INSTALLATION OF HEAD FLA ING AND WINDOW TRI (FOLLOWI STEPS). L J HEAD FLASHING PREPARATION SCALE: NTS (E) WALL UNDERLAYMENT NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. (z) CUT JAMB FLASHING TO EDGE OF WINDOW OPENING AS SHOWN. EXTEND 1-1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASH ING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D (E) SIDING NOT SHOU,N FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. — INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. /5 MEMBRANE FLASHING AT JAMB SCALE: NTS INSTALL SHT. METAL HEAD FLASHING UNDER (E) BLDG PAPER. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW I/8" BETWEEN FL BOT. EDGE SIDING LEARANCE SHING AND (E) TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. HEAD FLASHING INSTALLATION SCALE: NTS (E) WALL UNDERLAYMENT 3� MEMBRANE FLASHING AT HEAD SCALE: NTS INSTALL HEAD CUT HEAD FLASHING TO EDGE OF WINDOW OPENING 45 SHOWN. EXTEND 1-1/2" BEYOND R.O. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF UJALL SHEATHING (TYP. EACH SIDE OF WALL) NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. FLANGE FLASHING OVER WINDOW NAILING FLANGE ANP FLASHING. C6 WINDOW FLASHING INSTALLATION SCALE: NTS WOOD TRIM INSTALLATION SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE 1/4"-3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: I: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5 AND 6" REFER TO MEMBRANE INSTALLATION AFTER WINDOW 1445 BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "I AND 8" REFER TO SHEET METAL HEAD FLASHING. 5: DETAIL 5 REFERS TO WOOD TRIM AND CAULK JOINTS. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2013 City of BUILDING DIVISION l3I? RECEIVED CITY OF TUKWILA JUN 0 5 2013 PERMIT CENTER ■ S.M.STEMPER ARCHITE CTS A Professional Limited Liability Company 4000 DELRIDGR WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 REGISTERED AL-TECT OCTOBER 19, 2012 0810.03.2324 0 a_ J z 0 w z z 0 0 (9 z MPROVEMENTS >- 0 w w w 0 z LL 0 LLI AIP NUMBER 3-53-0058-045 DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW FLASHING DETAILS A2.3 0810.03.2324 1 1 WOOD TRIM INSTALLATION SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE 1/4"-3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: I: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5 AND 6" REFER TO MEMBRANE INSTALLATION AFTER WINDOW 1445 BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "I AND 8" REFER TO SHEET METAL HEAD FLASHING. 5: DETAIL 5 REFERS TO WOOD TRIM AND CAULK JOINTS. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2013 City of BUILDING DIVISION l3I? RECEIVED CITY OF TUKWILA JUN 0 5 2013 PERMIT CENTER ■ S.M.STEMPER ARCHITE CTS A Professional Limited Liability Company 4000 DELRIDGR WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 REGISTERED AL-TECT OCTOBER 19, 2012 0810.03.2324 0 a_ J z 0 w z z 0 0 (9 z MPROVEMENTS >- 0 w w w 0 z LL 0 LLI AIP NUMBER 3-53-0058-045 DATE OCTOBER 19, 2012 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW FLASHING DETAILS A2.3 0810.03.2324 LOCATION:: 1 SERVING:? RESIDENCE,. 120/240 VOL 10,000 AC, WIRE. 125 TAMP with MAIN k, BKR CKT LOAD DES 11.019 TYPE' KVA NP 30/2 7 11 13 15.,' 17 19 21 23 VEXISTING LOAD EXISTING LOAD 'E) ISTING LO EXISTING LOAD LISTING. LOAD 15/1 20/1 20/2 EXISTING LOAD 20/2 EX[S1TNG LOAD EXISTING LOI�D 20/1 HASE? A/P' A B' A A A 1511 2011_ 40/2 20/1, 20/1 >. 20/1 20/1 KVA TYPE 15/1 0/1 2011 20/1.2011 LOAD DESCRIPTION EXISTING LOADwT EXISTING LOAD EXISTING LOAD EXISTING LOAD CKT EXISTING LQAD, EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING I,.OAR; EX STING LOAD BLENDING 1+ 14 16 18 20. 22 24 4Q TYPE 1N.LOAD WH JTED LOAD, 0,12 0.12 ISOLATED GROUND BUS El $RAINTIGHT,NEMA3R;ENCLOSURE . FEED TFjRU LUGS MAIN BKR SHUNT DOUBLE LUGS . [) SERVICE' ENTRANCE LABEL 0.03 OTAL LOADS 012; KVA PAN EL SKIRTS INTEGRAL TVSS 0.15 KVA 0,63; ANP SURFACE FLUSH PROVIRE:(2jNE At 112 SIZE BREAD S T+D MATCH EXIS1I1NGSYSTEIGI. RE QNRGURE E7LSTING I OAD ON CKT 24,AS REQUIRED. SEE FLOOR PLANS FOR LOCATIONS OF BLENDING UNITS AND TIMER SWITCHES. 1\- 2#12NMB + G, OR EQUAL MP ELECTRICAL ONE -LINE NOT TO SCALE FAMILY ROOM STUDY LAUNDRY LOWER FLOOR PLAN 1/4" = 1' 1sEDIROOM 3 ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION G UGHTING OR POWER PANEL EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. VLI 111111 4 DAMPER CONNECTION D NON-FUSED DISCONNECT SWITCH o MAST, WEAINERHEAD ❑S' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN ®D SMOKE DETECTOR ELECTRICAL METER 1 'TIMER OPERATED SWITCH 11 AERIAL SERVICE CONDUCTORS, COORDINATE WI1H U11UTY. pT THERMOSTAT — - — 4E CEIUNG MOUNTED FIRE ALARM -VISUAL STROBE UGHT ® UNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN 5:00 PM. ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES CI PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. 0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. NORTH KITCHEN LIVING ROOM DINING ROOM U CL. n BEDROOM 1 22" x 30" EXIST. ATTIC ACCESS PANEL MAIN FLOOR PLAN 1/4" = 1' BATT -1 BEDROOM 2 9 RECEIVED CITY OF TUKWILA JUN 052013 ■ S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 ■NSINIIRB. INC XIII MOWN m. Meter. XOIM MX TAMA. WA MIMn. TilIpIO rM.411IWO WO MM VM MIM 0810.03.2324 O a. -J z 0 z H z z 0 0 Z (1) z w w 0 a. > 0 w w w 0 z u_ U 121 AIP NUMBER 5-53-0058-045 DATE SEPT 17, 2012 ISSUED 95% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN BCR FLOOR PLANS NOTES E1.0 0810.03.2324