Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D13-204 - KING COUNTY HOUSING AUTHORITY - TENANT IMPROVEMENT
KING COUNTY HOUSING AUTHORITY 600 ANDOVER PARK W D13-204 City oiikukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 2623049123 Address: 600 ANDOVER PK W TUKW Suite No: Project Name: KING COUNTY HOUSING AUTHORITY Permit Number: D13-204 Issue Date: 09/09/2013 Permit Expires On: 03/08/2014 Owner: Name: KC HOUSING AUTHORITY Address: 600 ANDOVER PARK W , TUKWILA WA 98188 Contact Person: Name: RICKY PHILLIPS Address: 625 ANDOVER PK W , TUKWILA WA 98188 Contractor: Name: REGENCY NW CONSTRUCTION INC Address: PO BOX 6429 , BELLEVUE WA 98008 Contractor License No: REGENNC041J5 Lender: Name: SELF FUNDED BY KCHA Address: Phone: 206 574-1217 Phone: 425-883-1301 Expiration Date: 03/02/2014 DESCRIPTION OF WORK: TENANT IMPROVEMENT OF 1795 SF OF FIRST FLOOR OF OFFICE SPACE. WORK TO INCLUDE DEMOLITION OF SELECTED INTERIOR PARTITION WALLS, NEW PARTITION WALLS FOR NEW ENCLOSED OFFICE AND NEW MAIL ROOM SPACE. EXISTING ACOUSTIC CEILING GRID TO REMAIN. MINOR ELECTRICAL AND MECHANICAL MODIFICATIONS TO BE MADE UNDER SEPARATE PERMITS. Value of Construction: $150,000.00 Fees Collected: $3,113.76 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY **continued on next page** doc: IBC -7/10 D13-204 Printed: 09-09-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: Private: Profit: N Private: N Date: Public: Non -Profit: N Public: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name:G15 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: New suspended ceiling grid and light fixture installations shall meet the non -building structures seismic design requirements of ASCE 7. doc: IBC -7/10 D13-204 Printed: 09-09-2013 7: All construction shall be done in conformath the approved plans and the requiremer the International Building Code or International Residential Co nternational Mechanical Code, Washington e Energy Code. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ***FIRE DEPARTMENT CONDITIONS*** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located' in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 21: Maintain fire extinguisher coverage throughout. 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) doc: IBC -7/10 D13-204 Printed: 09-09-2013 26: Aisles leading to required exits shall be S'ided from all portions of the building and tuired width of the aisles shall be unobstructed. (IFC 1013.4) 27: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 28: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 29: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 30: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 31: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 32: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 34: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 35: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 36: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. Joc: IBC -7/10 D13-204 Printed: 09-09-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. D19, - u" I Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 2623049123 Site Address: 600 Andover Park West Tenant Name: King County Housing Authority Suite Number: PROPERTY OWNER Name: Ricky Phillips Name: King County Housing Authority Address: 625 Andover Park West Address: 600 Andover Park West City: Tukwila State: WA City: Tukila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Ricky Phillips • Address: 625 Andover Park West City: Bellevue State: WA Zip: 98005 City: Tukwila State: WA Zip: 98188 Phone: (206) 574-1217 Fax: City: Seattle State: WA Email: rickyp@kcha.org Phone: GENERAL CONTRACTOR INFORMATION Company Name: TBD Address: Address: 12342 Northup Way City: Bellevue State: WA Zip: 98005 Phone: (425) 556-1220 Fax: (425) 556-1228 City: State: City: Seattle State: WA Zip: Phone: Fax: Email: nickrich@interfaceeng.com State: Contr Reg No.: Zip: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line \201 I Applications\pertnit Application Revised - 8-9-1 (.docs Revised: August 2011 bh New Tenant: Floor: 1 El Yes m .. No ARCHITECT OF. RECORD. Company Name: Lawhead Architects P.S. Architect Name: Frank Lawhead Address: 12342 Northup Way City: Bellevue State: WA Zip: 98005 Phone: (425) 556-1220 Fax: (425) 556-1228 Email: flawhead@lawhead.com ENGINEER OF RECORD Name: Company Name: Interface Engineering %� .,0' Engineer Name: Nicholas Rich Address: 1417 Fourth Avenue City: Seattle State: WA Zip: 98101 Phone: (206) 753-6020 Fax: City: Email: nickrich@interfaceeng.com State: ' LENDER/BOND ISSU'ED (required for projects $5,000 or greater per RCW 19.27.095)) Name: /, 1//1 _.5- 1, V /i %� .,0' Address: City: State: Zip: Page I of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 150,000 Existing Building Valuation: $ 1,971,800 Describe the scope of work (please provide detailed information): 1,795 sf of selected tenant improvement to the first floor of an existing office space. The tenant improvement will include demolition of selected interior partition walls, new partition wall construction for a new enclosed office and a new mail room space. Existing acoustical ceiling grid to remain in place, minor lighting changes to include removal and relocation of selected existing lights within the ceiling grid, and the addition of one new light. Minor mechanical modifications include addition of selected return air and supply diffusers in new enclosed rooms. Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes J No 1f "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \20I I Applications\Permn Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I5' Floor 9,120 1,795 0 0 V—B B 2"d Floor 9,830 0 0 0 V—B B 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes J No 1f "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \20I I Applications\Permn Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): The project is exclusively a minor interior tenant improvement of an existing building. There will be no exterior work. The tenant improvement will include demolition of selected interior partition walls, new partition wall construction for a new enclosed office and a new mail room space. Plumbing will not be affected and no new plumbing will be installed. Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila 0... Water District #125 ❑ ... Water Availability Provided Sewer District ❑ ...Tukwila 0 ...Sewer Use Certificate ❑ .. Highline ❑... Valley View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance 0 ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ...Total Cut O ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements O ...Traffic Control 0 ...Backflow Prevention - Fire Protection Irrigation Domestic Water 0 ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size.. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ❑ ...Water Main Extension Public ❑ ❑• ❑• ❑ , ❑ . ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line 51 11 WO # WO # WO # Private ❑ Private ❑ 0 .. Grease Interceptor ❑ .. Channelization 0 .. Trench Excavation 0 .. Utility Undergrounding ❑ ...Deduct Water Meter Size 51 FINANCE INFORMATION Fire Line Size at Property Line ... Water ... Sewer Monthly Service Billing to: Number of Public Fire Hydrant(s) 0 ...Sewage Treatment Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\Fortes-Applications On Line \201 I ApplicationsWertnn Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN : 0 HORIZED AGENT: Signature: Print Name: Ricky P Illips Mailing Address: 700 Andover Park West Suite C H:\Applications\Forms-Applications On Line \20I I Applications\Permit Application Revised - 8.9.11.docx Revised: August 2011 bh Date: 4/7/3 Day Telephone: (206) 574-1217 Tukwila WA 98188 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT ( QUANTITY PAID $65.00 D13-204 Address: 600 ANDOVER PARK W Apn:,2623049123 65.00 DEVELOPMENT PERMIT REINSPECTION FEE TOTAL FEES PAID BY RECEIPT: R2559 R000.322.800.00.00 0.00 $65.00 $65.00 Date Paid: Wednesday, July 09, 2014 Paid By: REGENCY NW CONSTRUCTION INC Pay Method: CREDIT CARD 07055J Printed: Wednesday, July 09, 2014 2:59 PM 1 of 1 CRWSYSTEMS City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 2623049123 Permit Number: D13-204 Address: 600 ANDOVER PK W TUKW Status: APPROVED Suite No: Applied Date: 06/10/2013 Applicant: KING COUNTY HOUSING AUTHORITY Issue Date: Receipt No.: R13-02579 Initials: WER User ID: 1655 Payment Amount: $1,888.90 Payment Date: 09/09/2013 02:34 PM Balance: $0.00 Payee: KING COUNTY HOUSING AUTHORITY TRANSACTION LIST: Type Method Descriptio Amount Payment Check 234689 1,888.90 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 Total: $1,888.90 1,884.40 4.50 Prin}ori• n0_!10_7n1'2 • r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 2623049123 Permit Number: D13-204 Address: 600 ANDOVER PK W TUKW Status: PENDING Suite No: Applied Date: 06/10/2013 Applicant: KING COUNTY HOUSING AUTHORITY Issue Date: Receipt No.: R13-01846 Payment Amount: $1,224.86 Initials: JEM Payment Date: 06/10/2013 12:51 PM User ID: 1165 Balance: $1,888.90 Payee: KING COUNTY HOUSING AUTHORITY TRANSACTION LIST: Type Method Descriptio Amount Payment Check 233928 1,224.86 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 1,224.86 Total: $1,224.86 Printprl• OR -10-2013 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 13 -7,464 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: C Z /t't'U5.� Type of Inspection:v V `�, l rU n nJ AI - Address: ! , A (/)(0/) �NOhJ(!' \fV Date Called: 1 �1 1� A--2 rrl Spe`cialInstructions: 47S Date ed:{ .-- 2:2-' (d' - p.m. 11 Requester: Phon �: -- s(6= 3443 []Approved per applicable codes. 0Corrections required prior to approval. COMMENTS: 2�'►�' j �0 M(i ?:1 f ,,- Insp ctor: Date, ,75t - r aet n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I' INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. ' CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 bi 3-20 Project: , Ty of Inspe tion: ` A¢droO \ `�av �-t1`j Date Called: -0 LA2(1%Q G Special Instructions: Date Wanted: a.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: V Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Di3-020 PERMIT NO. ' CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 ProjectTy 0 a of Iection: grfi ns t& i3� C1 (J M Address: f 1:1to Dat Called kZ1AJ6—•L--- ALA -114161e_, e , Nis D l a,J tom°/.. Special Instructions: -/25-6 S3-1301 .� A vie _ Date Wanted: a.m. Req gster` I ; !I l `i �Z Phon`- , 63 i -t 56S' �• Approved per applicable codes. Corrections required prior to approval. COMMENTS:. ), MLI1},p If P t-Ik.4AP-{ s 1 15 1 c:.i e -i• ,mac .Or -i riie-tom- a'. -..J :ie k)vvvl ; (---, e M 6615 f k6 - ALA -114161e_, e , Nis D l a,J tom°/.. ��I777��'yyy"""///111 Date- 1 G/ REIN TION FEE REQUIRED. Prior to next inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit / 3 -201 INSPECTION NO. PERMIT NO. G CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: K, G, 1-I-. .r Type of Inspection: ` �� >4 1� Address: (:i: AIV6 61Cr w Date ailed: Special Instructions: Date Wanted 'n / 5 �emn �+C. Requester: R Phone No: 42S-- Siff -.343 fr Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: Ins ector: a2 Date: 01 3 REINSPECTION FEEttt`EQUlf2EDIPrior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. G� CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:Type /'C, C.�'U Y i-J�S.-. of Inspection: -F/ A M E A6 Address: I (., c) u AN4OJrJ W Date Called: Special Instructions:r 0 -7 l S 1 Date Wanted: 3 . _• �� ..a.mi) p.m. Requester: Phone Approved per applicable codes. COMMENTS: Corrections required prior to approval. ra ctrl n -f -}e7._• -i0 -P 0-1 Dat '3 / Q REINSPECTION FEE REQUIRED rior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /3—F — 27 1 /3-S- 2Z? PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:izc 47 Type of Insp ion: f 4 )6;1,A - / Address:/445//1/7 Suite #: pQ9 A-P(A) Contact P rson: Special Instructions: Phone No.: IX/Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: /74%3 ,.Sprinklers: ..c .t Fire Alarm: 1 S FA h—A/A-/ 04 //4,,,„ Pre -Fire: Permits: a ,4 / Occupancy Type: 7 r i , i \ \ , Needs Shift Inspe tion: ye S Date: /74%3 ,.Sprinklers: ..c .t Fire Alarm: 1 S 'Hood & Duct: /y{s Monitor:/re_ "?-„-14-,,L, /_, //4,,,„ Pre -Fire: Permits: a ,4 / Occupancy Type: 7 $100.00 REINSPECTION FEE REQUIRED. Y'u will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Date: /74%3 Hrs.: J. ci Inspector: ��' 4-3 $100.00 REINSPECTION FEE REQUIRED. Y'u will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit P/ - U/ /3- .5- ac 3 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: . C / IA ,A./_9 Tyne of Inspection:/ , ti A ±�,4 4 - Address. � Suite #: 00 A (IA M1Contact Person: Special Instructions: "Phone No.: JJpproved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: S P -cr 1 pu t,4- — O< 2, .t4(--- -c 1 fU A L. — .e S ;,, c -,2o be S (c) 3 . cf 7_ —ci ot_f�9- L Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: WA G--- �, r-4 Date: ///26y,3 Hrs.: $ 00.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address' Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project - ( • /i7 Sprinklers: Type of Inspection: 5co u�/ Address. /„UU Suite #: (1i �� Permits: Contact Person: ' Special Instructions: Phone No.: pproved per applicable codes. Corrections required prior to approval. COMMENTS: 64. +0 rc,u-r_c— Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ,(th,, c'` -z____ Date: %j/� ���< Hrs.: $10.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: -State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 September 2, 2014 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Ricky Phillips King County Housing Authority 700 Andover Pk W, Ste C Tukwila, WA 98188 RE: Request for Extension Permit Number D13-204 Dear Mr. Phillips, This letter is in response to your written request for an extension to Permit D13-204. The Building Official has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through February 25, 2015. If you should have any questions, please contact our office at (206) 431-3670. Jen *ferHard • e t T hni File: Permit No. D13-204 W:\Permit Center\Extension Letters\Permits\2013\D13-204 Permit Extension.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Jennifer Marshall From: Ricky Phillips <RickyP@kcha.org> Sent: Friday, August 22, 2014 12:47 PM To: Jennifer Marshall Subject: Permit # D13-204 King County Housing Authority - TI Project Jennifer, I spoke to you on the phone regarding status of permit D13.204. KCHA received the letter notifying permit #D13-204 was nearing expiration date. I have been trying to work with the responsible contractor in getting final inspections complete. Unfortunately the contractor is not being responsive. KCHA has every intent in completing the requirements of City of Tukwila Building Department and final the building permit. Upon approval of extending the permit KCHA will resolve the open permit. Please take this email as our written request to extend the expiration date on permit D13-204 an additional 180-calader days. Thank you. Ricky Phillips I Project Manager I King County Housing Authority 700 Andover Park West Ste C Tukwila, WA 98188 I Phone: 206-574-1217 Fax: 206-315-6918 I TTY 800-833-8384 I www.kcha.orq 1 7/1/2014 • • City of Tukwila Department of Community Development RICKY PHILLIPS 625 ANDOVER PK W TUKWILA, WA 98188 RE: Permit No. D13-204 KING COUNTY HOUSING AUTHORITY 600 ANDOVER PK W Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 8/13/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 8/13/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 1;11 - Bill Rambo Permit Technician File No: D 13-204 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 @PERM1T COORD CO# PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-204 DATE: 06/10/13 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 600 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: /1-- Altic Building Division II Public Works AwC (42-)--H3 ■ Fire Prevention Structural CI St'( Planning Division Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete I Incomplete ❑ DUE DATE: 06/11/13 Not Applicable ❑ Comments: Permit Center',Use Only. INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route [- REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 07/09/13 Approved ❑ Approved with Conditions 2( Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use'Only .; s. CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: PLAN REVIEW CHECKLIST - (Nonstructural) By: Date: • Permit App. (3(i-. 20 L' IBC Edition (/ & State Amend. Project title:. < C - +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ›:( Classify the building or portion thereof in accordance with Chapter 3 (etermine the type of construction of the building in accordance with Chapter 6. Determine if the location of building on the site and clearances to property lines and other buildings on the site plan are in accordance with code provisions. Review for conformity with General building height and area limitations in accordance with Chapter 5. Review for conformity with special detailed requirements based on use and Occupancy. Review for conformity with Type of Construction requirements of Chapter 6. *C. -Review for conformity with Fire and Smoke protection features of Chapter 7. Review for conformity with requirements of interior finishes of Chapter 8. Q/Review for conformity with requirements for fire protection systems of Chapter 9. ©..,:teview for conformity with requirements for means of egress requirements of Chapter 10 Review for conformity with requirements of accessibility in accordance with Chapter 11, and ICC A117.1 Review for conformity with Washington State Energy Code. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ✓ In circle = topic has been reviewed for the application. X In circle = topic is not relevant to proposed scope of work. Contractors or Tradespeople Pr Friendly Page • General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name REGENCY NW CONSTRUCTION INC UBI No. 601696917 Phone 4258831301 Status Active Address Po Box 6429 License No. REGENNC041J5 Suite/Apt. License Type Construction Contractor City Bellevue Effective Date 4/25/1996 State WA Expiration Date 3/2/2014 Zip 98008 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status REGENNC052JS REGENCY N W CONSTRUCTION Construction Contractor General Unused 4/10/1995 2/24/1997 Archived Business Owner Information Name Role Effective Date Expiration Date FOOTE, BRIAN LEE President 01/01/1980 Bond Information Page 1 of 2 Bond 5 Bond Company Name TRAVELERS CAS & SURETY CO Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 103713311 02/20/2002 Until Cancelled $12,000.00 02/19/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date Date: 05/04/2012 Na19 Covigators Ins sf13cg10192270002/20/2013 Date: 02/20/2014 $1,000,000.0002/22/2013 18 Covigators Ins TBD 02/20/2013 02/22/2014 $1,000,000.0002/11/2013 17 Interstate Fire & Cas Co SGL1002891 02/20/2012 02/20/2013 $1,000,000.0002/17/2012 16 Interstate Fire & Cas Co SGL1002591 02/20/2011 02/20/2012 $1,000,000.0002/18/2011 15 INTERSTATE FIRE & CAS CO SGL1002190 02/20/2010 02/20/2011 $1,000,000.0002/19/2010 14 INTERSTATE FIRE & CAS CO SGL1001714 02/20/2009 02/20/2010 $1,000,000.00 02/19/2009 13 INTERSTATE FIRE a CAS SCL1001039 02/20/2008 02/20/2009 $1,000,000.00 02/15/2008 12 WESTCHESTER FIRE INS CO G2201187A002 02/20/2006 02/20/2008 $1,000,000.0002/16/2007 Summons/Complaint Information Cause County Complaint Judgment Status Payment Paid By 12-2-15975-1SEA KING Date: 05/04/2012 Date: Dismissed Date: https://fortress.wa.gov/lni/bbip/Print.aspx 09/09/2013 King County Housing Authority -Central Office T PROJECT TEAM OWNER: KING COUNTY HOUSING AUTHORITY 600 ANDOVER PARK WEST TUKWILA, WA 98188 (206) 574-1214 STEVE JEFFERIS ARCHITECT: LAWHEAD ARCHITECTS P.S. 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 FRANK LAWHEAD DEREK MICHEL PROJECT DESCRIPTION MECHANICAL/ ELECTRICAL: INTERFACE ENGINEERING 1417 FOURTH AVENUE SUITE 600 SEATTLE, WA 98101 (206) 753-6020 NICK RICH, ELECTRICAL REED LYONS, MECHANICAL INEIMMEIMMUMM THE PROPOSED PROJECT CONSISTS OF 1,795 SF OF SELECTED TENANT IMPROVEMENT TO THE FIRST FLOOR OF AN EXISTING OFFICE SPACE. THE TENANT IMPROVEMENT WILL INCLUDE DEMOLITION OF SELECTED INTERIOR PARTITION WALLS, NEW PARTITION WALL CONSTRUCTION FOR A NEW ENCLOSED OFFICE AND A NEW MAIL ROOM SPACE. EXISTING ACOUSTICAL CEILING GRID TO REMAIN IN PLACE, MINOR LIGHTING CHANGES TO INCLUDE REMOVAL AND RELOCATION OF SELECTED EXISTING LIGHTS WITHIN THE CEILING GRID, AND THE ADDITION OF ONE NEW LIGHT. MINOR MECHANICAL MODIFICATIONS INCLUDE ADDITION OF SELECTED RETURN AIR AND SUPPLY DIFFUSERS IN NEW ENCLOSED ROOMS. LEGAL DESCRIPTION THAT PORTION OF THE NORTHEAST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 26, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: COMMENCING AT THE SOUTHWEST CORNER OF THE SAID NORTHEAST QUARTER OF THE SOUTHEAST QUARTER; THENCE SOUTH 88' 12' 32" EAST 30.00 FEET TO THE POINT OF ORIGIN OF THE CENTERLINE ON THE P-17 DRAINAGE CHANNEL, WHICH CHANNEL CONTINUES SOUTH 88' 12' 32" EAST TO TERMINUS AT THE WESTERLY MARGIN OF CHRISTENSEN ROAD; THENCE CONTINUING SOUTH 88' 12' 32" EAST 360.00 FEET; THENCE NORTH 01' 47' 28" EAST 69.00 FEET TO THE NORTHERLY MARGIN OF MINKLER BOULEVARD; THENCE CONTINUING NORTH 01' 47' 28" EAST 319.00 FEET TO THE TRUE POINT OF BEGINNING OF THE PARCEL TO BE DESCRIBED HEREIN; THENCE FROM SAID TRUE POINT OF BEGINNING NORTH 88' 12' 32" WEST 360.00 FEET THE EASTERLY MARGIN OF ANDOVER PARK WEST AS RECORDED UNDER AUDITOR'S FILE NO. 6355529, VOLUME 5095, PAGES 63 AND 64, RECORDS OF KING COUNTY, WASHINGTON; THENCE ALONG SAID EASTERLY MARGIN NORTH 01' 47' 28" EAST 150.00 FEET; THENCE LEAVING SAID EASTERLY MARGIN SOUTH 88' 12' 32" EAST 360.00 FEET; THENCE SOUTH 01' 47' 28" WEST 150.00 FEET TO THE TRUE POINT OF BEGINNING. ARCHITECTURAL SYMBOLS 0 DOOR C.O. FLAG NOTE REVISION NOTES WINDOW C.O. WALL C.O. 8'-0" CEILING OR HEADER HEIGHT INTERIOR ELEVATIONS VICINITY MAP.... BUILDING SECTION PARTIAL SECTION WALL SECTION DETAIL. BUILDING GRIDS 600 Andover Park West, Tukwila, 98188, INDEX CS COVER SHEET ARCHITECTURAL Al -1 A2-1 AD2-2 A2-2 A2-3 A3-1 SITE PLAN OVERALL FLOOR PLAN DEMO FLOOR PLAN & RCP NEW FLOOR PLAN & RCP SCHEDULES & INTERIOR ELEVATIONS DETAILS MECHANICAL M2-1 FIRST FLOOR PLAN - MECHANICAL ELECTRICAL E0-1 ED2-1 E2-1 ELECTRICAL SYMBOL LIST DEMOLITION PLANS - ELECTRICAL NEW PLANS - ELECTRICAL ZONING INFORMATION JURISDICTION: SITE ADDRESS: PARCEL: TOTAL SITE AREA: PERMITTED SITE USE ZONE: PERMITTED USE: SPECIAL REGULATIONS: SETBACKS: PARKING REQUIREMENTS: CODE INFORMATION CITY OF TUKWILA 600 ANDOVER PARK WEST TUKWILA, WA 98188 #2623049123 54,120 SF (1.24 ACRES) TUC - TUKWILA URBAN CENTER OFFICE (NO CHANGE) N/A N/A NO CHANGE IN BUILDING USE OR SIZE CODE EDITION: OCCUPANCY (CH. 3): CONSTRUCTION TYPE (CH. 6): ALLOWABLE FLOOR AREA: (TABLE 503) ALLOWABLE AREA INCREASE: (SEC. 506.3 - SPRINKLER - 200%) BUILDING AREAS (GROSS) PROPOSED AREA OF TENANT IMPROVEMENT: 2009 IBC, WAC 51-50 2003 ANS, ICC/ANSI A117.1-2003 2009 IFC, WAC 51-54 2009 WSEC, WAC 51-11 2009 IMC, WAC 51-52 2008 NEC (NFPA 70), WAC 296-46B-010 (NFPA 110-2005), WAC 296-46B-010 2004 NESC C2-2007, WAC 296-46B-010 2009 UPC, WAC 51-56 & 51-57 TUKWILA MUNICIPAL CODE 'B' - BUSINESS V -B, FULLY SPRINKLERED 1ST STORY: 2ND STORY: 1ST STORY: 2ND STORY: 1ST STORY: 2ND STORY: TOTAL: 1ST STORY: 2ND STORY: TOTAL: 9,000 SF 9,000 SF 18,000 SF 18,000 SF 18,000 SF 36,000 SF 9,120 SF 9,830 SF 18,950 SF 1,795 SF O SF 1,795 SF SEPARATE PERMIT REQUIRED FOR: temechanted lectric aI tumbing rr ,. a Piping C'i7 of Tukwila BL. ''''SIC DIVISION Want Improvements GENERAL NOTES 1. CONTRACTOR SHALL VERIFY CONDITIONS. NOTIFY THE ARCHITECT OF ANY CONDITIONS INCONSISTENT WITH THE INTENT OF THE DRAWINGS PRIOR TO STARTING OR CONTINUING WORK IN THE AREA CONCERNED. CODE: 2. ALL WORK SHALL CONFORM TO APPLICABLE CODES AND LOCAL BUILDING REQUIREMENTS, WHICH INCLUDE THE MOST CURRENT EDITIONS OF THE INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS, INTERNATIONAL MECHANICAL CODE (IMC), NATIONAL ELECTRICAL CODE (NEC), INTERNATIONAL FIRE CODE (IFC), AND WASHINGTON STATE ENERGY CODE (WCES). 3. MECHANICAL, ELECTRICAL AND FIRE PERMITS TO BE APPLIED FOR UNDER SEPARATE APPLICATION BY CONTRACTOR. HAZMAT: 4. HAZARDOUS MATERIAL REMOVAL & DISPOSAL: THE CONTRACTOR WILL SUSPEND WORK IMMEDIATELY AND NOTIFY THE OWNER IF MATERIALS SUSPECTED OF BEING HAZARDOUS, AND NOT PREVIOUSLY IDENTIFIED ARE ENCOUNTERED IN THE COURSE OF THE CONTRACTOR'S WORK. DEMOLITION: 5. WHERE ITEMS ARE INDICATED ON PLANS TO BE DEMOLISHED, IT SHALL MEAN THE COMPLETE REMOVAL AND DISPOSAL OF THE ITEM INDICATED UNLESS OTHERWISE NOTED. CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR ALL ITEMS INCLUDING CUTTING AND PATCHING WORK. DIMENSIONS: 6. DO NOT SCALE DRAWINGS. 7. VERIFY DIMENSIONS SHOWN ON DRAWINGS. USE ONLY DIMENSIONS INDICATED. PRIOR TO STARTING OR CONTINUING WORK, NOTIFY ARCHITECT OF DISCREPANCIES OR CONDITIONS INCONSISTENT WITH THE INTENT OF THE CONSTRUCTION DOCUMENTS. 8. FINISHED SURFACE OF INFILL OR EXTENSIONS OF EXISTING PARTITIONS SHALL ALIGN WITH ADJACENT EXISTING SURFACES UNLESS OTHERWISE NOTED. COORDINATION: 9. COORDINATE ALL OPERATIONS WITH OWNER, SUCH AS AREAS USED FOR MATERIAL STORAGE, ACCESS TO AND FROM THE SITE, TIMING OF WORK AND REQUIREMENTS OF NOISE ORDINANCE. INSTALL DUST AND NOISE BARRIERS AS REQUIRED TO PROTECT EXISTING ADJACENT SPACES AND OCCUPANTS AND TO MAINTAIN AN ENVIRONMENT SUITABLE TO PERMIT CONTINUED OCCUPANCY OF ADJACENT SPACES. 10. PATCH AND REPAIR ALL EXISTING SURFACES AFFECTED BY DEMOLITION WORK. 11. VERIFY LOCATIONS OF EXISTING UTILITIES. CAP, MARK, AND PROTECT AS NECESSARY TO COMPLETE THE WORK. 12. REVIEW ARCHITECTURAL DRAWINGS AND PROVIDE ROUGH -INS THROUGH WALLS AND CEILINGS FOR DUCTS, PIPES, CONDUITS, JUNCTION BOXES, CABINETS, AND EQUIPMENT. VERIFY SIZE AND LOCATION BEFORE PROCEEDING WITH WORK. COORDINATE WITH INSTALLATION REQUIREMENTS. PATCH AND REPAIR EXISTING SURFACES AS NECESSARY TO COMPLETE WORK. 13. COORDINATE AND PROVIDE REQUIRED PENETRATIONS AND PATCHING WITH INDIVIDUAL SUBCONTRACTORS TO SUIT NEW WORK. 14. CONTRACTOR TO OBTAIN AND VERIFY ROUGH -IN DIMENSION REQUIREMENTS FOR CABINETRY, EQUIPMENT, ACCESSORIES AND THE LIKE. CONTRACTOR TO PROVIDE BACKING, BLOCKING, SUPPORT AS REQUIRED FOR INSTALLATION. CONTRACTOR TO COORDINATE POWER, DATA, COMMUNICATIONS, AND SECURITY REQUIREMENTS FOR EQUIPMENT WHERE SERVICES ARE REQUIRED. INCLUDE STUB OUTS AND CONNECTIONS. VERIFY AND COORDINATE DIMENSIONS PRIOR TO PROCEEDING WITH WORK. 15. PIPING, CONDUITS, DUCTS, ETC. SHALL BE CONCEALED IN WALLS, CHASES, ABOVE SUSPENDED CEILINGS, BELOW FLOORS, UNLESS OTHERWISE NOTED. 16. CAREFULLY COORDINATE MECHANICAL, ELECTRICAL, AND BUILDING SYSTEM INSTALLATIONS WITH EXISTING STRUCTURE AND BUILDING SYSTEMS. 17. REFER TO REFLECTED CEILING PLAN AND ELECTRICAL DRAWINGS FOR ELECTRICAL DEVICES AND LOCATIONS. COORDINATE AND REVIEW DEVICE LOCATIONS WITH ARCHITECT IN FIELD PRIOR TO ROUGH -IN. 18. REMOVE MEANS TO COMPLETELY AND PERMANENTLY REMOVE FROM THE PROJECT. FILE C PY Permit No. Plan review approval is At: --al of construction documents does not authorize Y a 11.r Receipt of approved Field Copy and .143 City Of ltikwlla BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. ReviaiOns will require a new plan submittal cml may include additional plan review fees. e - REVIEWED FOR LODE COMPLIANCE APPROVED IJUN 2 5 2013 s�- City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 102013 PERMIT CENTER \9)--2.0 LAWHEAD ARCHITECTS P.S. I I 12342 NORTHUP WAY 1 ELLli V UE, WA 98005 (425) 556-1220 FAX (425) 556-1228 SIGNATURE.L. 4565 REGISTERED , ARCHfTEC1 FRA E. LAWN A Ar STATE OF WASHINGTON OWNER... KING COUNTY HOUSING AUTHORITY 600 Andoizer Park West Tukwila, WA 98188 -I- O ci) v< tx)Q11) 7) 0 ot O � � urt U bo -t- Ensi PHASE... Permit Set JOB NO... 12-09 DATE... 6/5/13 SHEET TITLE... -t- Cover Sheet SHEET NO... Cs 343.85'Ta ?/v'r k/er B/vd •l7/afer/Wain TUKW//.A 600 511/L D/A/6 dorm ,Droin IN .U.. M ■ MOM ...r -:O. ONO ..1•10.r . - r. N ■ ire ■ �{. r MEM . - O1 NI Cvrb €�Gu ffer -141%16-'1%.— U G Power(/to/f- - ■ - ■ ` .. - ■ M ... Set /'2R0 7Tg 45 //568. Th/ep/ on e 5ervAcie Box Address: 600 Andover Pork' Wes"' Tu k wi /a, Wash i n g fo nn 98/86' Tofa/ Len Area: 54000 S. 7`a / Par//n g : 87 Spaces (Open) 30 'ingress ? tigress 'c✓sen,en (Recording No .77//23093) .L I I I �il/v7zer Service ANDOVER PA Re WEST z//o.6G"To L14 SW -andel- .5/vd ■ FO/ ■ ■ r S 1.1.E Y — ■ -. ■ - ■ er Son. Sewer . . ••••i1 ■ *mail (21=0208"E _/.50..00 —_____-- _. Se7`/' PPTy G.5;//58 /5' (11-77/ / y Erase/ner, (Recording No's 6 35552 9 ft 77//230 934) Ea'ge Of A sJha/7L 0 27 `C/ea r 5 L:E4serr2er1,/ T Huge/ Sound /Dower f=L ugh/ Co ( cording A/08007030465) S 88°/2 "32"E Edge, Of Asph a /7L 0.03 C/mar fd. /'i P, f' Tag LS, //568 Exist RR Tracks SITE PLAN (FOR REFERENCE ONLY) AREA OF WORK (FIRST FLOOR ONLY) 23.5i Rev/rood Easement. (eecording A/o's 7?/0060/4i 7 75042/0345, g` 77//230934) S 0/°47'21310/ /50.00' Se/Nat/ ?Tg ZS//558/n RR Tie 1" = 20'-0" a■ - •' N • .***L'.. REVIEWED FOR DE COMPLIANCE APPROVED F� r j. I JUN 2 5 2013 City of Tukwila BUILDING DIVISION �3- .113H RECEIVED CITY OF TUKWILA JUN 102013 PERMIT CENTER • LAWHEAD ARCHITECTS P.S. • I U 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 FAX (425) 556-1228 SIGNATURE... FRANK E. LAWHEAD STATS OF WASHINGTON 1 1 OWNER... KING COUNTY HOUSING AUTHORITY 600 Andover Park West Tukwila, WA 98188 -t- • -I.i eL q< t.o V � • O O Ttd $264 Lai 44 U bo -t- PHASE... Permit Set JOB NO... 12-09 DATE... 6/5/13 SHEET TITLE... Site Plan SHEET NO... Al -1 AREA OF WORK 1,795 SF OVERALL PLAN - AREA OF WORK (FIRST FLOOR ONLY) 1/8" = 1'-0" . w.s.i•YwWMy►,�i•.. , REVIEWED FOR CODE COMPLIANCE APPROVED IJUN252013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 102013 PERMIT CENTER LAWHEAD ARCHITECTS P.S. 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 FAX (425) 556-1228 SIGNATURE... 4565 REGISTERED ARCHITEC1 FRANK E. LAWHEAD STATE OF WASHINGTON OWNER... KING COUNTY HOUSING AUTHORITY 600 Andover Park West Tukwila, WA 98188 -r tL `j 111.4 ai) t<l) v u . CA � O o O � u "h4 0)E'4 U PHASE... Permit Set JOB NO... -t- 12-09 DATE... 6/5/13 SHEET TITLE... Overall Floor Plan -- SHEET NO... A2-1 GENERAL DEMOLITION NOTES 1. ALL WALL DIMENSIONS TO FACE OF FRAMING. 2. ALL WALL FINISHES TO BE GWB (OR WGWB) AND PAINT, TO MATCH EXISTING. VERIFY PLANS FOR NEW AND REMODELED WALL AREAS WHERE NEW FINISHES WILL BE REQUIRED. 3. CONTRACTOR TO VERIFY EXISTING PLAN DIMENSIONS. EXISTING ARCHITECTURAL, STRUCTURAL, MECHANICAL & ELECTRICAL CONSTRUCTION DRAWINGS ARE AVAILABLE FROM THE OWNER. THE CONSTRUCTION DRAWINGS MIGHT NOT MATCH EXACT FIELD CONDITIONS. FIELD VERIFY CONDITIONS OF CONCERN. 4. FOR NEW WALL CONSTRUCTION AND EXTENSION OF EXISTING WALLS, CONTRACTOR TO VERIFY AND MATCH EXISTING FINISHED WALL DIMENSION TO PROVIDE AN EVEN TRANSITION/FINISH TO THE NEW WALL CONSTRUCTION. 5. DEMO FLOORING & ASSOCIATED FLOOR BASE PER KEYNOTES, REPLACE WITH NEW FLOORING & FLOOR BASE PER FINISH SCHEDULE AND NEW FLOOR PLAN. 6. ALL CUT AND PATCH WORK NEEDED (WALLS, CEILINGS & FLOORS), WILL BE FINISHED TO MATCH EXISTING MATERIAL AND FINISH PER FINISH SCHEDULE AND SPECIFICATIONS. 7. FIRE PROTECTION SYSTEMS MODIFICATIONS SHALL BE BIDDER DESIGN. ACTUAL SYSTEM DESIGN, PIPE ROUTING AND SPRINKLER HEAD(S) LOCATION(S) SHALL BE COMPLETED BYA FIRE PROTECTION ENGINEER LICENSED IN THE STATE OF WASHINGTON AND SHALL COMPLY WITH NFPA 13. COORDINATE ALL WORK WITH ARCHITECT PRIOR TO INSTALLATION. 8. CONDITIONS MAY VARY FROM THOSE SHOWN. 9. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER BEFORE DEMOLITION TO IDENTIFY ITEMS TO BE SALVAGED AND TO CLARIFY DEMOLITION. THE CONTRACTOR IS TO REMOVE ALL DESIGNATED EQUIPMENT AND RETURN IN ORIGINAL CONDITION TO THE OWNER 10. PROTECT PORTIONS OF EXISTING BUILDING OR STRUCTURES WHICH ARE TO REMAIN AGAINST DAMAGE. 11. PROTECT ANY ITEMS OR EQUIPMENT TO REMAIN AGAINST DAMAGE. 12. WHERE EXISTING CONDITIONS ARE DEFACED OR MODIFIED DUE TO WORK PERFORMED, THE CONTRACTOR IS TO RESTORE SAME WITH FULL PIECES TO MATCH ADJOINING MATERIAL AND FINISH. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS CORNERS, CEILING LINES, TOP OF BASE AND SIMILAR. 13. VERIFY RELOCATION OR TERMINATION OF SERVICES IN WALLS OR CEILINGS TO BE REMOVED, COORDINATE WITH MECHANICAL AND ELECTRICAL. 14. ADDITIONAL DEMOLITION, NOT DIRECTLY INDICATED HERE MAY BE REQUIRED. A DEMOLITION PLAN KEYNOTES • THIS AREA N.I.C. • REMOVE CEILING TILE IN AREAS OF WORK AND STORE SALVAGEABLE UNITS FOR REUSE - DISPOSE OF WASTE; CEILING GRID TO REMAIN IN PLACE AND BE REUSED. O OWNER TO REMOVE ALL DEMOUNTABLE PARTITIONS AND ASSOCIATED OFFICE FURNITURE FOR REUSE - CONTRACTOR TO DISPOSE OF WASTE REMAINING. A\ OWNER TO REMOVE FILING CABINETS FOR REUSE. • REMOVE AND SALVAGE DOOR FRAME, DOOR PANEL, AND TRANSOM FOR FUTURE RE -USE. • REMOVE CASEWORK (UPPER TO BE SALVAGED AND RELOCATED, LOWER TO BE REMOVED) 8 REMOVE COUNTERTOP, NEW COUNTER TO BE INSTALLED. • REMOVE CARPET & BASE MATERIAL A REMOVE GWB WALL FACE, WALL TO BE ACOUSTICALLY UPGRADED A REMOVE PORTION OF WALL AT MULLION TO PREPARE FOR NEW ACOUSTIC MULLION, DETAIL 4/A3-1. A REMOVE UPPER CASEWORK. A REMOVE FIRE EXTINGUISHER CABINET & SIGN, RELOCATE PER 1/A2-2 LEGEND L E E EXISTING WALL DEMO LINETYPE DEMO WALL 2X4 FLUORESCENT ("E' FOR EXISTING, "N" FOR NEW, AND "R" FOR RELOCATE) 2X2 FLUORESCENT ("E" FOR EXISTING, AND "N" FOR NEW) WALL MOUNTED FIXTURE ("E" FOR EXISTING, AND "N" FOR NEW) FIRST FLOOR DEMOLITION PLAN 1/8" = 1'-0" • LAWHEAD ARCHITECTS P.S. 1111 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 FAX (425) 556-1228 SIGNATURE... 4565 REGISTERED ARCHITEC1 FRANn E. LAWHEAD STATE. OF WASHINGTON OWNER... KING COUNTY HOUSING AUTHORITY 600 Andover Park West Tukwila, WA 98188 a ••.Y•..- .' •.r.L REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 2 5 2013 City of Tukwila BUILDING DIVISION FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN 1/8" = 1.-0„ RECEIVED CITY OF TUKWILA JUN 102013 PERMIT CENTER • t -o • u) O cacii t40 • 1...1 ?-i PHASE... Permit Set JOB NO... 12-09 DATE... 6/5/13 SHEET TITLE... Demo Floor Plan & RCP SHEET NO... AD2=2 9'-0" BOTTOM OF A.C.T. ji 0'-0" T.O. FINISH FLOOR •.4 WALL TYPE 1 (ALL NEW WALLS) LEGEND I E E E BRACE AS REQUIRED TO STRUCTURE ABOVE ACOUSTICAL CEILING BATT INSULATION ONTOP OF EXISTING ACOUSTICAL CEILING, EXTEND OVER TOP OF WALL. EXTEND 4' EACH SIDE OF WALL EXISTING WALL NEW WALL 2X4 FLUORESCENT ("E" FOR EXISTING, "N" FOR NEW, AND "R" FOR RELOCATE) 2X2 FLUORESCENT ("E" FOR EXISTING, AND "N" FOR NEW) WALL MOUNTED FIXTURE ("E" FOR EXISTING, AND "N" FOR NEW) EXTEND WALL TO BOTTOM OF EXISTING DUCTWORK OR STRUCTURE. SISTER NEW STUDS TO EXTEND WALL ABOVE EXISTING ACOUSTICAL CEILING TYP. WALL ASSEMBLY: -5/eGWB/PT. - 1/2' RESILIENT CHANNEL (RC -1) @ 24" O.C. - 3 518' METAL STUDS @ 24" O.C. - 3" MIN. ACOUSTICAL INSULATION -5/8'GWB/PT. ACOUSTIC UPGRADE ASSEMBLY: - 3" MIN. ACOUSTICAL INSULATION - 1/2' RESILIENT CHANNEL (RC -1) @ 24" O.C. -5/8"GWB/PT. BOTTOM TRACK BASE PER PLAN & FINISH SCHEDULE. NEW FINISH FLOOR PER PLAN, TYP. GENERAL NOTES 1. CUT CEILING TRACK AND PROVIDE NEW TRACK WHERE REQUIRED AT NEW WALLS. 2. PROVIDE 1/4" MIN. OF ACOUSTICAL CAULK AT ALL INSIDE AND OUTSIDE CORNERS OF NEW WALL CONSTRUCTION (DETAIL 13/A3-1) AND AT THE BASE OF WALL (DETAIL 2/A2-2). 3. SEE MECHANICAL AND ELECTRICAL FOR ADDITIONAL CEILING GRID PENETRATIONS. A PLAN KEYNOTES THIS AREA N.I.C. • NEW ENTRY COUNTER, SEE 10/A2-3 3Q N/A • NEW CASEWORK A DEMOUNTABLE PARTITIONS AND OFFICE FURNITURE TO BE REUSED • TWO (2) NEW OPEN SHELF LATERAL FILE CABINETS WITH FIVE (5) SHELVES • RELOCATED SECURE FILE CABINET PROVIDE SOUND BATT INSULATION ONTOP OF CEILING TILE - ONTOP AND 4' EACH SIDE OF WALL BELOW • REUSE SALVAGED DOOR FRAME, DOOR PANEL, AND TRANSOM. SEE DETAIL 2/A3-1 FOR NEW JAMB CONDITION • NEW MAILBOX SYSTEM A PATCH/PAINT WALLS WHERE NEEDED, MATCH EXISTING FINISH/COLOR A FLUSH NEW WALL WITH EXISTING CONSTRUCTION. NEW WALL TO MATCH EXISTING WALL CONSTRUCTION. A ACOUSTICALLY UPGRADED WALL, SEE WALL TYPE 2 BELOW A ACOUSTICAL MULLION CONNECTION, SEE DETAIL 4/A3-1 • REFINISH END OF LOWER CASEWORK WITH P -LAM TO MATCH EXISTING CASEWORK • RELOCATED SALVAGED UPPER CABINETS, REMOVE PAIR OF DOORS AND ASSOCIATED SHELVING AT END, REUSE END PANEL. A RELOCATED FIRE EXTINGUISHER CABINET AND SIGN A FLOORING TRANSITION, SEE SPECIFICATIONS FOR DETAIL. A APPROXIMATE CENTER OF SPACE FOR CARPET TILE LAYOUT, VERIFY ACTUAL DIMENSION/LOCATION. NEW CARPET TILE LAYOUT AND PATTERN PER SPECIFICATIONS, ACCENT COLORS TO BE RANDOMLY DISTRIBUTED: 62% - (Field 1) Sew Straight Pattern 30% - (Field 2) Primary Stitch Pattern 2% - (Accent 1) Viva Colores Color Teja Pattern 2% - (Accent 2) Viva Colores Cano Pattern 2% - (Accent 3) Viva Colores Marron Pattern 2% - (Accent 4) Viva Colores Verde Primavera Pattern EXISTING WALL (SHADED) ACOUSTIC CAULK @ BASE OF WALL TO FLOOR NEW WALL TYPES WALL TYPE 2 (ACOUSTICALLY UPGRADED WALL) 3/4" = i -- -; ---1 --1 I r - Ir r-- 1 r r r - a r r r a r a - Ci7F1E2ENCiEE- r--9;08 r C 09 r .r - 11 fr r - - -- , r- -- -- - r-- r--; r--� --; r --I r-- I ---� - --� - ---I r --a r r , a --I a -- -a r-- ; r --I -- a -- , a -- r r-- - -I s r--- I ---H - r-- 11----1 r-- r-- , - H r--- _r---;tt r - ✓ --OF 1dE --x 1 r -- r --I , I i ----I 196"- r ---I j -- - --I r-- r-- ' 1--- , r-- , -- ; r-- r I �---- -4 1--- - --� r- r-- r-- F -_-1 , _b -- , -- -- r-- -- r-- i -- i - J 1--J r-- i t J � � r, r- , r- , r-- r- , r-- , r Ht --- --a r.. r , 1 -) - t - r -a LLr--a ---I r-- ; r -- CV to w r 1-- -I -I 1011-- i -- r---1 r --I, r --a r--, r- - \ r r r - 1a r -- r- r --I �---1 r---1, 1---1 r --I 1-- 1---1 r - , r --a I - r- r-- r --a r- I r- ---) ---I a r a I --- t -1 J i I 1 e-1 1 H -1 - --i 1 I 1 I r - --I Ff IC --; r---1 r---1 r --1 r-- , r--1 -I r---; ' —I - 1 5- r---1 - '1----1 k---1 --I -- I r -- r-- r-- r- r- -- a 'r--� r-- ; r__� r _� r - r r b- j --a �---I _ -- -j --; 1- a 1-OIFJ� k--11--- -1, --a r-- r-- r r-- r -- r_ -II---- , r --a r I--1102----1 -- r a r i ]I i j i I I i —i - --I r ; -- , L �10 ' a -- ® r-- r --=r , - r --j--- _ -� r-- , rr_ -- -- r- r - r r -- r-- r--, r--, r --a r--; rI -- r- -1 r-- r ---1,_ 1 -) r---) Y--- r--1 r --a - r-- r- r--j----I, -- 1----1,_ -- r r --a r--� - k- ..� --a -- ---i ---1 ---a r-- r --I r-- , �- Q3; �- I r-}- urs r - - r r-- r-- r-� r I r - I r-- r-- -- r --I - r r r a r r --1 r --a I VERIFY CARPET TILE PLAN 1/8" = 1 A OtICE 108 A A FFICE 109 A CONFERENCE 110 4 --AAA OFFICE 107 0 in ci L 4'-0" F - .0 - OPEN OFFICE 106 A 7 A—o VERIFY 14'-2 1/2" 9 -4 3/4" VERIFY CLEAR IM OFFICE 104 FIRST FLOOR PLAN 1/8" = 1'-0" LAWHEAD ARCHITECTS P.S. ■ ■ I 12342 NORTHUP WAY BELLE VUE, WA 98005 (425) 556-1220 FAX (425) 556-1228 SIGNATURE... FRANK E. LAWHEAD STATE OF WASHINGTON 1- OWNER... KING COUNTY HOUSING AUTHORITY 600 Andover Park West Tukwila, WA 98188 -t- OFFICE CONFERENC EN OFFICE MAIL/STOR. 101 R .13 OFFICE REVIEWED FOR DE COMPLIANCE APPROVED OFFICE D JUN 25 2013 City of Tukwila BUILDING DIVISION FIRST FLOOR REFLECTED CEILING PLAN .LO y 1/8" = 1'-0" bo "44 4! Lmmi14.4 H PHASE... Permit Set JOB NO... 12-09 DATE... 6/5/13 SHEET TITLE... New Floor Plan & RCP RECEIVE CITY OF TUKWILA JUN 102013 PERMIT CENTER SHEET NO... A2-2 NEW CASEWORK (LOWER) OPEN OFFICE 106 (LOWER & UPPER) \ NEW M,kILBOX SYStEM MAIL/STOR. 101 0 NEW LATERAL FILE STOR. NEW LATERAL FILE STOR. 9'-4 3/4" ENLARGED FLOOR PLAN 1/4" = 1'-0" SALVAGED SECURE FILING CABINET !4 N 4 EQUAL sAY n sNy 4,-9" 3 EQUAL 101 MAIL/STOR. 1' NEW ELEC. OUTLET, COORDINATE LOCATION WITH OWNER MAILBOX SYSTEM RUBBER BASE, TYP. 1/4" = 1'-O" RUBBER BASE, TYP. 6 101 MAIL/STOR. OPEN SHELF LATERAL FILING CABINET (5 - SHELVES), SEISMICALLY RESTRAINED. 1/4" = 1'-0" 100 HALL RUBBER BASE, TYP. 1/4" = 1'-0" P /. / FLOOR 41:7 y 4'-0" NORTH EAST SOUTH WEST ' -I /1,, 100 HALL CPT TILE RUBBER GWB/PT. GWB/PT. GWB/PT. GWB/PT. NOTE 1 NOTE 1 101 MAIL/STOR. CPT TILE RUBBER GWB/PT. GWB/PT. GWB/PT. GWB/PT. NOTE 1 NOTE 1 102 OFFICE CPT TILE RUBBER GWB/PT. GWB/PT. GWB/PT. GWB/PT. NOTE 1 103 11 CPT TILE RUBBER GWB/PT. NOTE 2 NOTE 2 ' NOTE 2 NOTE 1 104 OFFICE CPT TILE N NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 1 In OFFICE CPT TILE RUBBER GWB/PT. GWB/PT. NOTE 2 NOTE 2 NOTE 1 106 OPEN OFFICE CPT TILE RUBBER NOTE 2 NOTE 2 GWB/PT. NOTE 2 NOTE 1 107 OFFICE CPT TILE RUBBER NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 1 108 OFFICE CPT TILE RUBBER NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 1 109 OFFICE CPT TILE RUBBER NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 1 110 CONFERENCE CPT TILE RUBBER GWB/PT. GWB/PT. GWB/PT. GWB/PT. NOTE 1 4 EXIST. COLUMN —/ N 10'-0" EQ. 100 HALL MAIL/STOR. ROOM 101 WALL BEHIND MAILBOX SYSTEM RUBBER BASE, TYP. 1/4" = 1'-0" MAILBOX SYSTEM 101 MAIL/STOR. RUBBER BASE, TYP. 1/4" = 1'-0" LATERAL FILING CABINET BEHIND 101 MAIL/STOR. CASEWORK BEHIND RUBBER BASE, TYP. 1/4" = 1'-0" FINISH SCHEDULE NO. SPACE NAME FLOOR BASE NORTH EAST SOUTH WEST CEILING REMARKS 100 HALL CPT TILE RUBBER GWB/PT. GWB/PT. GWB/PT. GWB/PT. NOTE 1 NOTE 1 101 MAIL/STOR. CPT TILE RUBBER GWB/PT. GWB/PT. GWB/PT. GWB/PT. NOTE 1 NOTE 1 102 OFFICE CPT TILE RUBBER GWB/PT. GWB/PT. GWB/PT. GWB/PT. NOTE 1 103 HR CPT TILE RUBBER GWB/PT. NOTE 2 NOTE 2 ' NOTE 2 NOTE 1 104 OFFICE CPT TILE RUBBER NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 1 105 OFFICE CPT TILE RUBBER GWB/PT. GWB/PT. NOTE 2 NOTE 2 NOTE 1 106 OPEN OFFICE CPT TILE RUBBER NOTE 2 NOTE 2 GWB/PT. NOTE 2 NOTE 1 107 OFFICE CPT TILE RUBBER NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 1 108 OFFICE CPT TILE RUBBER NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 1 109 OFFICE CPT TILE RUBBER NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 1 110 CONFERENCE CPT TILE RUBBER GWB/PT. GWB/PT. GWB/PT. GWB/PT. NOTE 1 NOTES: 1. EXISTING CEILING TILE TO BE REMOVED IN AREAS OF WORK SALVAGEABLE UNITS REUSED; CEILING GRID TO REMAIN IN PLACE AND BE REUSED. REPLACE DAMAGED CEILING TILE AND GRID. 2. REPAINT EXISTING WALLS. LEGEND: GWB: PT: GYPSUM WALLBOARD PAINT CPT TILE: CARPET TILE DOOR SCHEDULE NO. WIDTH x HT. DOOR TYPE MAT./FIN. FRAME MAT./FIN. HEAD DETAILS JAMB THRESH. HARDWARE REMARKS 100A 3'-0" x 7'-0" EXIST. SCWD/STN HM / PT 2/A3-1 2/A3-1 — NOTE 1 NOTE 1 100B 3'-0" x 7'-0" EXIST. SCWD/STN HM / PT 2/A3-1 2/A3-1 — NOTE 1 NOTE 1 101 3'-0" x 7'-0" C SCWD/STN HM / PT 6/A3-1 6/A3-1 — 1 102 3'-0" x 7'-0" B SCWD/STN HM / PT 1 & 5/A3-1 1/A3-1 — 1 106 3'-0" x 7'-0" A SCWD/STN HM / PT 6/A3-1 6/A3-1 — 1 NOTES: 1. EXIST. DOOR FRAME, PANEL, HARDWARE (INCL. ASSOCIATED KEYPAD), & TRANSOM REUSED. REFINISH PANEL AND REPAINT FRAME. 2. ALL DOOR HARDWARE MUST MEET THE ICC /ANSI A117.1-2003 STANDARD. LEGEND: SCWD: SOLID CORE WOOD STN: STAIN HM: HOLLOW METAL PT: PAINT COPY/FAX COPY/FAX MACHINE BY OWNER NEW ELEC. OUTLET, COORDINATE LOCATION WITH OWNER RUBBER BASE, TYP. 1/4" = TEMPERED / SAFETY GLASS, 6" �£ TYP. 0 DOOR N- HARDWARE: 1. NEW DOORS A. LOCKSET: SCHLAGE, AL50PD WITH SATURN LEVER B. HINGES: (3) MCKINLEY, T2714 C. STOP: TRIMCO, 1270CV D. SILENCERS: TRIMCO, 1229A (0 0 M A 4 3'-0" 0 N- N. TEMPERED "I 3'-0" SAFETY GLASS, 'I TYP. B 0 N- / LAWHEAD ARCHITECTS P.S. 12942 NORTHUP WAY BE• LLEV UE, WA 98005 (425) 556-1220 FAX (425) 556-1228 SIGNATURE... 4565 hREGISTERED n ' ARCHITEC1 \....FRA E. LAWHEAD STATE OF WASHINGTON OWNER... KING COUNTY HOUSING AUTHORITY 600 Andover Park West Tukwila, WA 98188 C (3) STEEL SUPPORT. BRACES, PAINT EDGE OF WALL BELOW, VERIFY LOCATION COUNTERTOP PLAN 2"4, P -LAM FINISH REVIEWED FOR CODE COMPLIANCE `',c APPROVED 1 JUN 2 5 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 102013 PERMIT CENTER ‘414 QJ 1.4 1414 H PHASE... Permit Set JOB NO... 12-09 DATE... 6/5/13 SHEET TITLE... Schedules & Int. Elevations SHEET NO... A2-3 9 VINYL BASE NEW WALL, PER FLOOR PLAN VINYL COVE BASE, MITER CUT INSIDE CORNERS, WRAP OUTSIDE CORNERS, TYP. CARPET PER FINISH SCHEDULE ACOUSTICAL SEALANT 3" = 1'-0" �5 1 1/2" 1 1/ 1/4"EDGE CLEARANCE ALL AROUND SEALANT CONTINUOUS, EACH SIDE APPROVED GLAZING TAPE OR GLAZING COMPOUND AS SUPPLIED BY GLASS MANUFACTURER 1/4" GLAZING RELITE @ JAMB (HEAD SIM) 3" = 1'-0" 2 -17 1 1/2"/ 1 t t 1/4" GLAZING 1 1/2" APPROVED GLAZING TAPE OR GLAZING COMPOUND AS SUPPLIED BY GLASS MANUFACTURER STEEL FRAME 1/4" EDGE CLEARANCE ALL AROUND RELITE @ DOOR HEAD 3" = 1'-0" 1/4" STEEL SUPPORT: 3" WIDE, SPACING PER PLAN. WELD ALL CONNECTIONS, PAINT BLOCKING AS REQUIRED OR ATTACH DIRECTLY TO FRAMING EXISTING WALL (SHADED) NEW WALL CONSTRUCTION SEALANT CONTINUOUS, EACH SIDE 1/2" GWB FILLER 3/8" J TRIM, PAINT TO MATCH EXISTING DOOR FRAME EXISTING DOOR FRAME & RELITE RELITE @ JAMB (HEAD SIM.)3" = 1'-0" 00 SEALANT CONTINUOUS, EACH SIDE STEEL FRAME ANCHORS, 3 PER JAMB, MIN. DOOR JAMB (HEAD SIM.) 3" = 1'-0" MAINTAIN EXIST. OAK BASE COUNTERTOP SECTION R 7-3/16" 1 1/2"= 1'-0" 1 _ P -LAM FINISH PLYWOOD, 2 LAYERS OAK WOOD TRIM, STAIN CHAIR RAIL @ COUNTER 1' = 1,-0" UPPER CABINET METAL STANDARDS INTERIOR TO BE WHITE MELAMINE, TYP. 3/4" PLWD W/ P -LAM @ ALL EXPOSED SURFACES 2'-2" / 1 1/2"= 1'-0" P LAM AT BACKSPLASH & ALL EXPOSED SURFACES DIM. POINT DRAWER ON GLIDES /72 /// /// 1 DRAWER AND CABINET CONFIGURATION PER ELEVATIONS, TYP. �7 BASE CABINET MTL. STANDARDS ROUT TO FLUSH WITH INTERIOR SURFACE 3/4" BOX W/ WHITE MELAMINE FINISH 3/4" PLYWOOD ADJUSTABLE SHELF RUBBER BASE 1 1/2"= 1'-0" TRIM @ COUNTER OAK TRIM, STAIN 1' = 1'-0" GASKET WITH ACOUSTICAL ADHESIVE, BOTH SIDES EXISTING WOOD SILL ACOUSTICAL SEALANT NEW ACOUSTICAL WALL MULL -IT -OVER TRIM CAP, BOTH SIDES (VERIFY PROFILE NEEDED AT EACH LOCATION). TRIM CAP TO MATCH PROFILE OF WOOD SILL AND WINDOW FRAME, APPLY COLOR MATCHED ACOUSTICAL SEALANT AT JOINTS INTERIOR WALL @ MULLION3" = 1'-0" /// // 3/4" PLYWOOD W/ P.LAM TOP & EDGE //// P. LAM FACE MELAMINE INT. FINISH s COUNTER EDGE DOOR OR DRAWER P.LAM ALL SURFACES = 1'-0" LAWHEAD ARCHITECTS P.S. ■ ■ ■ 12942 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 FAX (425) 556-1228 SIGNATURE... 4565 bt3--2.6/4 r� 3 1/4" CONTINUOUS —"AUSTICAL SEALANT, TYP. ACOUST. WALL CORNER REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 2 5 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 102013 PERMIT CENTER 3" = 1'-0" -r REGISTERED ARCHITEC1 FRANK E. LAWHEAD STATE OF WASHINGTON OWNER... 0 PHASE... t Permit Set JOB NO... 12-09 DATE... 6/5/13 SHEET TITLE... Details SHEET NO... A3-1 ( DIFFUSER, REGISTER AND GRILLE SCHEDULE SYMBOL TYPE FACE FRAME DAMPER FINISH BASIS OF DESIGN REMARKS G-1 CEILING RETURN GRILLE EGGCRATE LAY -IN NONE WHITE 11TUS 50R D-1 CEILING DIFFUSER LOUVERED LAY -IN NONE WHITE 11TUS TMS OFFICE E (4) U 1 FIRST FLOOR PLAN - MECHANICAL 0 4' 8' 16' SCALE: 1/8"=1'-0" D 32DL4 SEPARATE PERMIT AND APPROVAL REQUIRED GENERAL MECHANICAL NOTES A. DO NOT SCALE PLANS. VERIFY DIMENSIONS PRIOR TO FABRICATION AND INSTALLATION OF MECHANICAL SYSTEMS. B. MECHANICAL DRAWINGS ARE SCHEMATIC LEVEL AND DIAGRAMMATIC ONLY. ACTUAL SIZE AND LOCATION OF EQUIPMENT, DUCTWORK AND PIPING MAY VARY DUE TO MANUFACTURER OR ACTUAL FIELD CONDITIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE INSTALLATION OF MECHANICAL SYSTEMS WITH OTHER TRADES AND SYSTEMS SO AS TO PROVIDE ADEQUATE CLEARANCE AND ACCESSIBILITY AS REQUIRED BY MANUFACTURER'S RECOMMENDATION AND AS SHOWN ON PLANS. C. FIELD VERIFY ALL EXISTING DUCT AND PIPE LOCATIONS AND SIZES PRIOR TO ANY FABRICATION OR ORDERING OF EQUIPMENT. NOTE THAT SOME DUCTWORK IS TO BE RE -USED WHILE OTHERS ARE TO BE REMOVED. D. CONCEAL ALL PIPING AND DUCTWORK INSIDE WALLS AND ABOVE CEILING UNLESS SHOWN OTHERWISE. E. REFER TO ARCHITECTURAL PLANS TO VERIFY ALL LOCATIONS OF NEW FIRE RATED ASSEMBLIES. ALL DUCT PENETRATIONS OF FIRE RATED ASSEMBLIES SHALL BE PROTECTED BY FIRE DAMPERS. F. FIRE SAFE ALL DUCT AND PIPE PENETRATIONS THROUGH FIRE RATED ASSEMBLIES. G. AREAS BEING REMODELED SHALL BE RE -BALANCED TO LISTED CFM'S BY NEBB CERTIFIED. H. ALL NEW DUCTWORK SHALL BE INSULATED WITH 1" DUCT WRAP WITH VAPOR BARRIER. INSULATED FLEXIBLE DUCT SHALL NOT EXCEED 5'-0" IN LENGTH. I. ALL WORK SHALL COMPLY WITH INTERNATIONAL MECHANICAL CODE AND ALL STATE AND LOCAL REVISIONS. J. BUILDING ENVELOPE/INSULATION SHALL NOT BE MODIFIED. GENERAL SHEET NOTES A. ALL RETURN AIR IS DUCTED IN WOODEN STRUCTURE. B. DIFFUSERS NOTED ARE: (E) EXISTING TO REMAIN. NEW CFM NOTED, NO DUCT REVISION (R) EXISTING TO BE RELOCATED. NEW CFM NOTED. D-1 NEW LAY -IN DIFFUSER. CFM NOTED. 6" DUCT CONNECTION G-1 NEW LAY -IN RETURN GRILLE. DUCT SIZE AS NOTED. C. EXISTING THERMOSTAT SHALL BE RELOCATED AS NOTED. D. LOCATION OF ZONE VAV BOXES ARE SHOWN AS V -X WITH THE NUMBER CORRESPONDING TO THE NOTED ZONE. E. EXISTING SPRINKLER HEAD LOCATIONS ARE SHOWN. DESIGN/BUILD FIRE SPRINKLER CONTRACTOR SHALL ADJUST HEAD LOCATIONS TO PROVIDE FIRE SPRINKLER PROTECTION TO NEWLY CONFIGURED SPACES AS PER NFPA 13 AND AHJ REQUIREMENTS. PROVIDE NEW SPRINKLER HEADS. COMPLY WITH ASCE 7-2005 FOR SPRINKLER PENETRATIONS 0 SHEET KEYNOTES 1 (N.I.C.) 2 (N.I.C.) 3 (N.I.C.) 4 RELOCATE EXISTING GRILLE. CAP EXISTING RETURN AIR DUCT AND CONNECT RELOCATED GRILLE TO EXISTING DUCT WITH 6" ROUND DUCT. 5 CONNECT NEW GRILLE TO EXISTING RETURN AIR DUCT WITH '10"0 DUCT. 6 CONNECT NEW GRILLE TO EXISTING RETURN AIR DUCT WITH 6"0 DUCT. 7 (N.I.C.) MECHANICAL LEGEND 0 —x—x—x—x— `- X"0 MD RA SA O RECEIVED CITY OF TUKWILA JUN 102013 PERMIT CENTER CEILING SUPPLY DIFFUSER CEILING RETURN GRILLE EXISTING DUCTWORK DEMOLITION WORK FLEXIBLE DUC ROUND DUCT MANUAL DAMPER t • T.AWHEAD ARCHITECTS P.S. • • 12342,Tstor.Tt ILIP WAY BIiLLEVCE, WA MO (425),55I -7220 FAX (42$) 556-1228 SIGNATURE... OWNER... KING COUNTY HOUSING AUTHORITY 600 Andover Park West Tukwila, WA 98188 BREAK IN DUCT (USE WHERE SECTION OF PIPING IS OMITTED FROM DRAWING FOR CLARITY) EQUIPMENT CALL -OUT RETURN AIR SUPPLY AIR EXISTING SEMI -RECESSED PENDENT SPRINKLER IN ACOUSTIC TILE CEILINGS POINT OF CONNECTION PROJECT 2013-0121 CONTACT Reed Lyons • 1417 Fourth Avenue Suite 600 Seattle, WA 98101 TEL 206.382.0200 FAX 206.382.0202 www.interfaceengineering.com INTERFACE ENGINEERING Co 1999 Interface Engineering Inc., Consulting Engtneeni M Rights Reserved, Including the right of reproduction in whole or in part, in any form. t PHASE... Permit Set JOB NO... 12-09 t DATE... 4113 SHEET TITLE... First Floor Plan - Mechanical t REVISIONS... SHEET NO... M2-1 OFFICE OFFICE C 13ENCF I( 108 109; J 10 O O ; O I - (E) � - I �� EXISTING T _ SUPPLY--- -- OPEN OFE ICE z _DUCT _. — L1s17 !; !(E)T (E) ' LJ - (E) oo 1 ZONE ZONE iii 7 � 120 - - il G.i.... 1 2 (R) , — I �� ; I 1 •�_-.. E) VAV-2 Mc • O • ," ® ]rte E �i►� Dp 1 R VAV-4 (E) _OFT'-(- ---I--- - IF -1 • • .._ - -_ VAV-5 (E) (E) (E) T e� `- , }_' �'�i - Li _ •O I _, (E) VAV-6 �+ I WS 113 -NA � s .----- �'�FFICE VAV_� � T (R � A.1 `� � I�� � T -------- _ � ZONE _'-- 5 �'" D—� 1Z}2 D=1 140 - - ()TICE —1:0iix -- - 280 D . ZONE 1_.. — x.:_._.. —o— ..n.` --- T'Ill (°R/4 T G Po E )-.. ® OZONE 3 �Qo u- \ _ .... i; O S" `/ 16 i'�. _______ , OFFICE 11 L J E S� © (E) 1801 fFI CE 112 E _T -i I (E2- 0 HR ---- (E) 220 �� 60 �._. -... 103;l_., C-� f_ OPEN FFICE - 1 - 160 11 ZO„` -- 1 a a 1 a I I I I --- `� I I I I I ` I I I i a I I a ��' -- _ (4) U 1 FIRST FLOOR PLAN - MECHANICAL 0 4' 8' 16' SCALE: 1/8"=1'-0" D 32DL4 SEPARATE PERMIT AND APPROVAL REQUIRED GENERAL MECHANICAL NOTES A. DO NOT SCALE PLANS. VERIFY DIMENSIONS PRIOR TO FABRICATION AND INSTALLATION OF MECHANICAL SYSTEMS. B. MECHANICAL DRAWINGS ARE SCHEMATIC LEVEL AND DIAGRAMMATIC ONLY. ACTUAL SIZE AND LOCATION OF EQUIPMENT, DUCTWORK AND PIPING MAY VARY DUE TO MANUFACTURER OR ACTUAL FIELD CONDITIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE INSTALLATION OF MECHANICAL SYSTEMS WITH OTHER TRADES AND SYSTEMS SO AS TO PROVIDE ADEQUATE CLEARANCE AND ACCESSIBILITY AS REQUIRED BY MANUFACTURER'S RECOMMENDATION AND AS SHOWN ON PLANS. C. FIELD VERIFY ALL EXISTING DUCT AND PIPE LOCATIONS AND SIZES PRIOR TO ANY FABRICATION OR ORDERING OF EQUIPMENT. NOTE THAT SOME DUCTWORK IS TO BE RE -USED WHILE OTHERS ARE TO BE REMOVED. D. CONCEAL ALL PIPING AND DUCTWORK INSIDE WALLS AND ABOVE CEILING UNLESS SHOWN OTHERWISE. E. REFER TO ARCHITECTURAL PLANS TO VERIFY ALL LOCATIONS OF NEW FIRE RATED ASSEMBLIES. ALL DUCT PENETRATIONS OF FIRE RATED ASSEMBLIES SHALL BE PROTECTED BY FIRE DAMPERS. F. FIRE SAFE ALL DUCT AND PIPE PENETRATIONS THROUGH FIRE RATED ASSEMBLIES. G. AREAS BEING REMODELED SHALL BE RE -BALANCED TO LISTED CFM'S BY NEBB CERTIFIED. H. ALL NEW DUCTWORK SHALL BE INSULATED WITH 1" DUCT WRAP WITH VAPOR BARRIER. INSULATED FLEXIBLE DUCT SHALL NOT EXCEED 5'-0" IN LENGTH. I. ALL WORK SHALL COMPLY WITH INTERNATIONAL MECHANICAL CODE AND ALL STATE AND LOCAL REVISIONS. J. BUILDING ENVELOPE/INSULATION SHALL NOT BE MODIFIED. GENERAL SHEET NOTES A. ALL RETURN AIR IS DUCTED IN WOODEN STRUCTURE. B. DIFFUSERS NOTED ARE: (E) EXISTING TO REMAIN. NEW CFM NOTED, NO DUCT REVISION (R) EXISTING TO BE RELOCATED. NEW CFM NOTED. D-1 NEW LAY -IN DIFFUSER. CFM NOTED. 6" DUCT CONNECTION G-1 NEW LAY -IN RETURN GRILLE. DUCT SIZE AS NOTED. C. EXISTING THERMOSTAT SHALL BE RELOCATED AS NOTED. D. LOCATION OF ZONE VAV BOXES ARE SHOWN AS V -X WITH THE NUMBER CORRESPONDING TO THE NOTED ZONE. E. EXISTING SPRINKLER HEAD LOCATIONS ARE SHOWN. DESIGN/BUILD FIRE SPRINKLER CONTRACTOR SHALL ADJUST HEAD LOCATIONS TO PROVIDE FIRE SPRINKLER PROTECTION TO NEWLY CONFIGURED SPACES AS PER NFPA 13 AND AHJ REQUIREMENTS. PROVIDE NEW SPRINKLER HEADS. COMPLY WITH ASCE 7-2005 FOR SPRINKLER PENETRATIONS 0 SHEET KEYNOTES 1 (N.I.C.) 2 (N.I.C.) 3 (N.I.C.) 4 RELOCATE EXISTING GRILLE. CAP EXISTING RETURN AIR DUCT AND CONNECT RELOCATED GRILLE TO EXISTING DUCT WITH 6" ROUND DUCT. 5 CONNECT NEW GRILLE TO EXISTING RETURN AIR DUCT WITH '10"0 DUCT. 6 CONNECT NEW GRILLE TO EXISTING RETURN AIR DUCT WITH 6"0 DUCT. 7 (N.I.C.) MECHANICAL LEGEND 0 —x—x—x—x— `- X"0 MD RA SA O RECEIVED CITY OF TUKWILA JUN 102013 PERMIT CENTER CEILING SUPPLY DIFFUSER CEILING RETURN GRILLE EXISTING DUCTWORK DEMOLITION WORK FLEXIBLE DUC ROUND DUCT MANUAL DAMPER t • T.AWHEAD ARCHITECTS P.S. • • 12342,Tstor.Tt ILIP WAY BIiLLEVCE, WA MO (425),55I -7220 FAX (42$) 556-1228 SIGNATURE... OWNER... KING COUNTY HOUSING AUTHORITY 600 Andover Park West Tukwila, WA 98188 BREAK IN DUCT (USE WHERE SECTION OF PIPING IS OMITTED FROM DRAWING FOR CLARITY) EQUIPMENT CALL -OUT RETURN AIR SUPPLY AIR EXISTING SEMI -RECESSED PENDENT SPRINKLER IN ACOUSTIC TILE CEILINGS POINT OF CONNECTION PROJECT 2013-0121 CONTACT Reed Lyons • 1417 Fourth Avenue Suite 600 Seattle, WA 98101 TEL 206.382.0200 FAX 206.382.0202 www.interfaceengineering.com INTERFACE ENGINEERING Co 1999 Interface Engineering Inc., Consulting Engtneeni M Rights Reserved, Including the right of reproduction in whole or in part, in any form. t PHASE... Permit Set JOB NO... 12-09 t DATE... 4113 SHEET TITLE... First Floor Plan - Mechanical t REVISIONS... SHEET NO... M2-1 ELECTRICAL SYMBOL LIST NOTE: This is a standard symbol list and not all items listed may be used. Abbreviations (E) EXISTING A AMPERES, AMBER AFC ABOVE FINISHED CEILING AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHJ AUTHORITY HAVING JURISDICTION AIC AVAILABLE INTERRUPTING CAPACITY ANSI AMERICAN NATIONAL STANDARDS INSTITUTE ARF ABOVE RAISED FLOOR AWG AMERICAN WIRE GAUGE BAS BUILDING AUTOMATION SYSTEM C CONDUIT, CLOSE, CONTROL CA CABLE CAT CATEGORY CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED CFOI CONTRACTOR FURNISHED OWNER INSTALLED COORD COORDINATE (D) DEMOLITION ENT ELECTRICAL NON—METALLIC TUBING FBO FURNISHED BY OTHERS FF FINISH FLOOR FMS FACILITY MANAGEMENT SYSTEMS FT FOOT, FEET G, GND GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER GFI GROUND FAULT INTERRUPTER IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS IN INCH, INCHES KV KILOVOLT KVA KILOVOLT AMPERES KW KILOWATT LED LIGHT EMITTING DIODE LNC LIQUID TIGHT FLEXIBLE NONMETALLIC CONDUIT MCA MINIMUM CIRCUIT AMPS MISC MISCELLANEOUS MOCP MAXIMUM OVERCURRENT PROTECTION MT, MTD MOUNT, MOUNTED N/A NOT APPLICABLE NEC NATIONAL ELECTRIC CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NTS NOT TO SCALE OFCI OWNER FURNISHED, CONTRACTOR INSTALLED OFOI OWNER FURNISHED, OWNER INSTALLED (R) RELOCATION REQD REQUIRED RFI REQUEST FOR INFORMATION SPD SURGE PROTECTION DEVICE SPKR SPEAKER STD STANDARD TBB TELECOMMUNICATIONS BONDING BACKBONE TBD TO BE DETERMINED TGB TELECOMMUNICATIONS GROUNDING BUS BAR TP TRANSITION POINT TTB TELEPHONE TERMINAL BOARD TYP TYPICAL UL UNDERWRITERS LABORATORIES V VOLTS, VOLTAGE Connections / Equipment El COMBINATION ADJUSTABLE FREQUENCY DRIVE WITH SAFETY DISCONNECT SWITCH EP HEAVY DUTY FUSED DISCONNECT SWITCH JUNCTION BOX Q WALL—MOUNTED JUNCTION BOX MOTOR CONNECTION NON—FUSED DISCONNECT SWITCH TRANSFORMER 0 OR ❑J ❑J General LOCATION EXISTING WORK NEW WORK DETAIL NUMBER AND SHEET LOCATION EQUIPMENT IDENTIFICATION FOOD SERVICE EQUIPMENT / CALCULATION TAG KEYED NOTE POINT OF CONNECTION SECTION NUMBER AND SHEET LOCATION Liahting EXIT SIGN CEILING MOUNTED, ARROW(S) INDICATES DIRECTION IF SHOWN EXIT SIGN WALL MOUNTED, ARROW(S) INDICATES DIRECTION IF SHOWN .-❑ AREA LUMINAIRE ARM MOUNTED WITH POLE AND CONCRETE BASE I RECESSED FLUORESCENT 2' X 2' LUMINAIRE CONNECTED TO EMERGENCY/LIFE SAFETY CIRCUIT OR WITH INTEGRAL EMERGENCY BATTERY CONNECTED TO UNSWITCHED CIRCUIT RECESSED FLUORESCENT 2' X 2' LUMINAIRE ON CRITICAL POWER RECESSED FLUORESCENT 2' X 4' LUMINAIRE RECESSED FLUORESCENT 2' X 4' LUMINAIRE ON CRITICAL POWER WALL MOUNTED LUMINAIRE WALL MOUNTED LUMINAIRE ON CRITICAL POWER Miscellaneous #10 B-27,29,31. G ■nr HI' ED BRANCH CIRCUIT WIRING. ARROW INDICATES HOME RUN TO PANEL WITH CIRCUITS AS NOTED. WIRE SIZE IS #12 AWG MINIMUM UNLESS NOTED OTHERWISE. SHORT TICK MARKS INDICATE PHASE CONDUCTORS. LONG TICK MARKS INDICATE NEUTRAL CONDUCTORS. A SINGLE CURVED TICK MARK INDICATES INSULATED GREEN GROUND CONDUCTOR. SECOND CURVED TICK MARK INDICATES "ISOLATED GROUND" (GREEN INSULATION WITH YELLOW STRIPE) CONDUCTOR. BRANCH PANEL FLUSH WALL MOUNTED BRANCH PANEL GROUNDING POINT MAIN DISTRIBUTION PANEL / SUB DISTRIBUTION PANEL CEILING MOUNTED SPEAKER PUSH BUTTON Raceways CONDUIT/WIRING STUBBED OUT WITH END CAP OR INSULATED PLASTIC BUSHING EXISTING CONDUIT CONCEALED IN WALL OR CEILING SPACE EXISTING CONDUIT ROUTED BELOW FLOOR / GRADE Switches and Receptacles DUPLEX RECEPTACLE (MULTIPLE LETTERS INDICATE MULTIPLE OPTIONS) A = ABOVE COUNTER B = CLOCK HANGER C = FLUSH CEILING MOUNTED E = EMERGENCY F = ARC FAULT PROTECTED BY BREAKER IN PANEL G = GROUND FAULT CIRCUIT INTERRUPTER H = HOSPITAL GRADE K = CHILD RESISTANT COVER L = ISOLATED GROUND P = PENDANT MOUNTED WITH CORD GRIPS. VERIFY PENDANT LENGTH S = SPLIT WIRED T = TAMPER RESISTANT SHUTTERED RECEPTACLE W = WEATHERPROOF CONTINUOUS USE COVER, GFCI PROTECTED, WITH WEATHER—RESISTANT RECEPTACLE ? = DESIGNER DEFINED DUPLEX RECEPTACLE, FLUSH FLOOR DOUBLE DUPLEX RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX RECEPTACLE FOR OPTIONS SINGLE RECEPTACLE, FLUSH FLOOR SINGLE RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX RECEPTACLE FOR OPTIONS CEILING MOUNTED OCCUPANCY SENSOR P = PASSIVE INFRARED D = DUAL TECHNOLOGY U = ULTRASONIC, 360 DEG RANGE H = ULTRASONIC, HALLWAY PATTERN WALL MOUNTED OCCUPANCY SENSOR P = PASSIVE INFRARED D = DUAL TECHNOLOGY EH WALL MOUNTED OCCUPANCY SENSOR/SWITCH S = PASSIVE INFRARED WITH INTEGRAL "OFF" SWITCH T = DUAL RELAY PASSIVE INFRARED WITH TWO INTEGRAL "OFF" SWITCHES D = PASSIVE INFRARED WITH INTEGRAL DIMMER TO OFF. MULTIPLE CHANNEL SURFACE METAL RECEPTACLE RACEWAY WITH LOW VOLTAGE DIVIDERS, LENGTH AND RECEPTACLES AS INDICATED PHOTO ELECTRIC SWITCH D = CONTINUOUS DIMMING PHOTOCELL S = SWITCHED PHOTOCELL SINGLE POLE SWITCH 2 = DOUBLE POLE SWITCH 3 = THREE—WAY SWITCH 4 = FOUR—WAY SWITCH a THRU z (LOWERCASE) = LUMINAIRE CONTROL DESIGNATION D = DIMMER F = FAN SPEED CONTROL K = KEY OPERATED SWITCH L = LIGHTED HANDLE M = MANUAL MOTOR STARTER WITH THERMAL OVERLOAD P = SWITCH WITH PILOT LIGHT S = SENTRY SWITCH T = INTERVAL TIMER W = WEATHERPROOF SWITCH V = LOW VOLTAGE SWITCH ? = DESIGNER DEFINED SWITCH Telecommunications V TELECOMMUNICATION OUTLET. PROVIDE DOUBLE GANG BACK BOX AND SINGLE GANG ADAPTER PLATE WITH 1" C. TO ACCESSIBLE CEILING SPACE. SEE SHEET KEYNOTES FOR ADDITIONAL INFORMATION. (MULTIPLE LETTERS INDICATE MULTIPLE OPTIONS) A = ABOVE COUNTER C = CEILING MOUNTED ABOVE ACCESSIBLE CEILING F = FLUSH CEILING MOUNTED R = SURFACE MOUNTED ON RACEWAY VIDEO SURVEILLANCE CAMERA GENERAL TECHNOLOGY NOTES A. COMMUNICATIONS RACEWAYS, TRAYS, AND OUTLETS ARE SHOWN DIAGRAMMATICALLY. LOCATIONS ARE APPROXIMATE UNLESS SPECIFICALLY DIMENSIONED. FIELD COORDINATE WORK WITH OTHER TRADES. B. TELECOM LOCATIONS AT NEW WALLS REQUIRE DOUBLE GANG BACK BOX WITH SINGLE GANG ADAPTER AND 1" CONDUIT TO ACCESSIBLE CEILING SPACE. C. REFER TO ARCHITECTURAL PLANS FOR FIRE RATING OF WALLS AND FLOORS. D. EXISTING LOCATIONS THAT ARE ABANDONED REQUIRE BLANK COVER. GENERAL SHEET NOTES A. PROVIDE DEFERRED APPROVAL AND DESIGN BUILD FOR REQUIRED MODIFICATIONS TO THE EXISTING FIRE ALARM SYSTEM. SUBMIT REQUIRED DRAWINGS TO THE AHJ FOR APPROVAL AND ASSUME FULL RESPONSIBILITY OF THE SYSTEM, DEVICE QUANTITY AND LOCATION, WIRING, PROGRAMMING AND CONTROL PANELS. COORDINATE FINAL DEVICE LOCATIONS WITH THE ARCHITECT PRIOR TO ROUGH—IN. B. DEMOLITION: MAINTAIN CONTINUITY OF CIRCUITS FOR EXISTING OUTLETS AND LIGHTING WHICH REMAIN IN PLACE. C. CLEANING: IN AREAS WHERE CONSTRUCTION WILL CAUSE DUST CONTAMINATION (SUCH AS HARD WALL REPLACEMENT), PRIOR TO START OF WORK PROVIDE BAG FOR LUMINAIRES, AND COVER SENSORS AND WIRING DEVICES SO THAT DUST INTRUSION DOES NOT OCCUR. AT CONCLUSION OF WORK, CLEAN ELECTRICAL EQUIPMENT TO PRE—CONSTRUCTION CONDITIONS. D. NOTICE TO PLAN REVIEWER: THIS OFFICE RENOVATION WORK ENTAILS NO CHANGES TO THE EXISTING OCCUPANT LOAD OR PATH OF EGRESS. EGRESS LIGHTING NO REVISIONS HAS BEEN MADE. E. EXISTING LIGHTING: REMOVE, PROTECT AND INSTALL EXISTING LIGHTING AS SHOWN ON LIGHTING DEMOLITION AND LIGHTING DRAWINGS. F. EXISTING LIGHTING CONTROLS: REMOVE, PROTECT AND INSTALL EXISTING OCCUPANCY SENSORS AS SHOWN ON LIGHTING DEMOLITION DRAWINGS. LIGHTING DRAWINGS SHOW WHERE OCCUPANCY SENSORS ARE TO BE LOCATED FOR CONTROL IN EACH ROOM SPACE. G. COORDINATE WORK SCHEDULE AND ANY DISRUPTION OF POWER WITH THE KING COUNTY HOUSING AUTHORITY. H. CONTRACTOR IS RESPONSIBLE FOR COMPLETING AND SUBMITTING APPLICABLE PERMITS, STUDIES, AND OTHER LOCAL AND STATE REQUIREMENTS. CONTRACTOR IS ALSO RESPONSIBLE FOR RELATED PERMITTING FEE'S. I. ALL WORK TO COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC). • ,AWHEAD Al:G'HITECTS P.5. U ■ I 2342 .NOR1111,..IP WAY. .5ELL,EV1 E, 9:$008' (410.556-122(1 'Ai (42'$) 5: E 11 4E: SIGNATURE... SHEET INDEX OWNER... KING COUNTY HOUSING AUTHORITY 600 Andover Park West Tukwila, WA 98188 ma"( I u E C 5 PHASE... Permit Set JOB NO... 12-09 E0-1 ELECTRICAL SYMBOL LIST & LUMINAIRE SCHEDULE DATE... RECEIVED ED2-1 FIRST FLOOR DEMOLITION PLAN — ELECTRICAAITY OF TUKWILA 4113 E2-1 FIRST FLOOR PLAN — ELECTRICAL A (3-.2U4 SEPARATE PERMIT AND APPROVAL REQUIRED JUN 102013 SHEET TITLE... PERMIT CENTER Electrical Symbol List & Luminaire Schedule REVISIONS... PROJECT CONTACT 2013-0121 Michael Nelson INTERFACE ENGINEERING 1417 Fourth Avenue Suite 600 Seattle, WA 98101 TEL 206.382.0200 FAX 206.382.0202 www.interfaceengineering.com O 1099 Interface Engineering Inc., Consulting Engineers All Rights Reserved, Including the right of reproduction In whole or in part, In any form. t SHEET NO... EO -1 � D) 1 FIRST FLOOR DEMOLITION PLAN - LIGHTING 0 4' 16' SCALE: 1/8"=1'-0" CES (E) TELECOM RACK (IDF/MDF) (26,27 (D) roil mita (E) (30,31) (E) PANEL 'PA2' (E) MDP N.I.0 (E) _ (34,35) ( (E) PANEL 'LA' (E) PANE (E) (E) (E) (E) 2 CHANNEL RACEWAY ANNEL Y 2 FIRST FLOOR DEMOLITION PLAN - POWER & SIGNAL 0 4' 8' 16' SCALE: 1 /8"=1'-0" GJ GENERAL SHEET NOTES A. COORDINATE DEMOLITION WORK WITH ARCHITECT AND BUILDING OWNER PRIOR TO COMMENCEMENT OF WORK. B. WHERE REMOVAL OF A POWER, COMMUNICATION DEVICE OR LUMINAIRE, WALL OR PORTION OF THE CIRCUIT INTERRUPTS EXISTING CONDUIT AND/OR CIRCUIT AND RESULTS IN LOSS OF CIRCUIT CONTINUITY, REROUTE, EXTEND AND RECONNECT REMAINING CONDUIT AND/OR CIRCUIT AS REQUIRED TO PROVIDE CONTINUITY OF THE CIRCUIT THAT REMAINS IN SERVICE. C. SEE GENERAL SHEET NOTES ON E0.1 FOR ADDITIONAL DEMOLITION INFORMATION. 0 SHEET KEYNOTES 1 EXISTING WHITE NOISE/CANCELLATION SPEAKERS ARE TO REMAIN. 2 EXISTING SECURITY CAMERA TO BE REMOVED AND REINSTALLED IN SAME LOCATION AND DIRECTION. 3 REMOVE EXISTING POWER POLE. REMOVE EXISTING WIRE WIRING BACK TO JUNCTION BOX/SPLICE. 4 EXISTING CARD READERS TO BE RELOCATED AS SHOWN IN DRAWING E2-1. 5 EXISTING DATA PORTS TO BE RELOCATED. SEPARATE PERMITAND APPROVAL REQUIRED ..1.....0,..,.,..E •arft.400 09 RECEIVED CITY OF TUKWILA JUN 102013 PERMIT CENTER PROJECT 2013-0121 CONTACT Michael Nelson 1417 Fourth Avenue Suite 600 Seattle, WA 98101 TEL 206.382.0200 FAX 206.382.0202 www.interfaceengineering.com 1 - LAWHEAD ARCHITECTS RS. ■ ■ 1.9.141.:NaktaaP: WAY .BLLLEY'LdE, liCaMg1,5 (425) 55h'-722(1 FAQ: (42$)'.5..,50 -UM SIGNATURE... SIGNATURE... INTERFACE ENGINEERING Including Morrowright ineertng Inc., Consulting Engineers All Rights Reserved, ng the r1 g repr nation in whole or in part, In any form. OWNER... KING COUNTY HOUSING AUTHORITY 600 Andover Park West Tukwila, WA 98188 PHASE... Permit Set t JOB NO... 12-09 t DATE... 4113 SHEET TITLE... First Floor Demolition t Plan -Electrical REVISIONS... SHEET NO... ED2-1 OPEN OFFICE• i')h D_ �2 4 1 FIRST FLOOR PLAN - LIGHTING 0 4' 16' SCALE: 1/8"=1'-0" E) F CA) ® ED) 2 FIRST FLOOR PLAN - POWER & SIGNAL 0 4' 8' 16' SCALE: 1/8"=1'-0" (G) EH) 3 4� GENERAL SHEET NOTES A. EXISTING POWER OUTLETS, COMMUNICATIONS AND EQUIPMENT MUST REMAIN UNLESS INDICATED AS DEMOLITION. REFER TO DRAWING ED2.1. B. CONFIRM EXISTING SPARE CAPACITY IN EXISTING PANELBOARDS PRIOR TO INSTALLING ANY WIRING DEVICES. C. EXISTING RECEPTACLE LOCATIONS ARE BASED ON EXISTING AS—BUILT DRAWINGS. CONTRACTOR TO CONFIRM EXISTING LOCATIONS. D. FOR ALL NEW DEVICES; MATCH COLOR AND FINISH OF EXISTING. E. FOR NEW ELECTRICAL CONNECTIONS SHOWN, PROVIDE CONNECTION TO EXISTING CIRCUITS AND RELATED CONDUCTORS AS SHOWN. PROVIDE THWN-2 CU CONDUCTORS WITH A MINIMUM SIZE OF #12 AWG ROUTED IN 3/4" EMT CONDUIT. MC CABLE IS ALSO AN APPROVED ALTERNATIVE. LOCATE ALL DEVICE OUTLETS IN MINIMUM 4—INCH SQUARE, 1-1/2" DEEP OUTLET WIRING BOXES. PROVIDE GALVANIZED STEEL OUTLET WIRING BOX, OF THE TYPE, SHAPE AND SIZE, INCLUDING DEPTH OF THE BOX TO SUIT EACH RESPECTIVE LOCATION AND INSTALLATION. F. PROVIDE CODE REQUIRED QUANTITY OF EXIT SIGNS PER CITY AND STATE LIGHTING CODES. CONNECT ANY NEW EXIT SIGNS TO EXISTING UNSWITCHED EXIT LIGHT CIRCUITS. 0 SHEET KEYNOTES 1 REMOVE AND RELOCATE AN (E) EXISTING LIGHTING FIXTURE TO A LOCATION AS INDICATED ON THE PLAN, TYPICAL OF 4. 2 PROVIDE A 'N' (NEW) LIGHTING FIXTURE; PARAMAX PARABOLIC TROFFER 2'X2' 277V AS INDICATED ON THE PLAN. THE NEW LIGHTING FIXTURE MODEL SHOULD BE EQUIVALENT TO LIGTHONIA 2PM3N OR AN APPROVED EQUAL. 3 PROVIDE POWER TO A NEW RECEPTACLE AS SHOWN BY CONNECTING TO AN EXISTING CIRCUIT NEARBY. 4 PROVIDE DEDICATED CIRCUIT TO NEW COPY/PRINTER CONNECT TO EXISTING CIRCUIT PA2-29. NEW 2 PORT TELECOM OUTLET WITH (2) CAT6 CABLES TO EXISTING TELECOM BACKBOARD/SWITCH AND 3/4" C. WITH PULLSTRING TO ACCESSIBLE CEILING SPACE. ROUTE (2) CAT -6 CABLES CONCEALED TO NEAREST TELECOM IDF/MDF ROOM. CONTRACTOR TO CONFIRM OWNER PREFERRED CONNECTION LOCATION PRIOR TO BID. 6 PROVIDE NEW DUAL TECHNOLOGY OCCUPANCY SENSOR AS SHOWN. WATTSTOPPER DT -300 SERIES OR APPROVED. PROVIDE POWER PACK AND OTHER EQUIPMENT AND CONNECTIONS NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM. 7 PROVIDE NEW IR OCCUPANCY SENSOR SWITCH; MATCH EXISTING TYPE, FINISH, AND CONTROL FUNCTION. 8 CONNECT SWITCH INTO EXISTING ROOM LIGHTING CONTROLS. 9 PROVIDE POWER AND CONTROL TO (R) RELOCATED LIGHTING BY CONNECTING TO AN EXISTING CIRCUIT NEARBY. 10 EXISTING SECURITY CAMERA TO BE REMOVED AND REINSTALLED IN SAME LOCATION AND DIRECTION. • ,AWHEAD ARCHITECTS PS. 1111 111 111 1.234.2;NORTt4T.PtAAY 'RELt.EVUE. rt x.$0113' (425.) .5564220 H¢ X (420;FCatr1:.22tt; SIGNATURE... SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED CITY OF TUKWILA JUN 102013 PERMIT CENTER PROJECT CONTACT 2013-0121 Michael Nelson INTERFACE ENGINEERING 1417 Fourth Avenue Suite 600 Seattle, WA 98101 TEL 206.382.0200 FAX 206.382.0202 www.interfaceengineering.com Includi9in Ith rfraxhEf rear duan Inowhoenor Ianipart, inI wfo mRaerval, OWNER... KING COUNTY HOUSING AUTHORITY 600 Andover Park West Tukwila, WA 98188 PHASE... Permit Set JOB NO... 12-09 DATE... 4113 t SHEET TITLE... First Floor Plan - t Electrical REVISIONS... SHEET NO... E2-1 0 - E) ' - O (E) E) (E) E) (E) 111 --- ------ -ICE I OFFICE (E) 109 CONFERENCE (E)• 110 - OFF 108 _O(E),♦ -+ ... _... (E) (IDF/MDF) -...................:........................................ TELECOM RACK � (E) �) OFFICE 107 (E) •C) (E)k,rp ' +42 +42 ABOVE Q (E) i. ,I11 n COUNTER. p (E) II (E) (E) IYP. (E) = -- ....__...._.. --- e 1 (E) (E) 7 PA2-7 © (E) PA3-10 ------ OPEN OFFICE'_ 106 (E) 31 -? (E) PA2- 29 � K - F f�- HALL -- - (•E) 100 ----- ----- ---- u — PA2-9 I _• I.' K ...--2,— /\ — III -- — -- — — — — — — (E) PA3 6,2 28,29 9 , I is 1 - = MAIL/STS' 101 (E) f = ---_ __ __. 9 :. N.LC T 31 22 ? ' �.�.C 'PA2' _ (E) __' ER (E) PANEL I' (E) MDP lr i� (E) INNS -'(E) ♦,i 17,18 OFFICE: =�+� 33 ' 33 (E�i_ PA2(E 1 (E) i (E) 105 E) _PA2-22 - - I 3031 OFFICE ►y PA2-3 Q ;E)C O� T _ �1 D (E) (E) (E) L ) W5 r' (E) PANEL 'LA' (E) P �� PA -17 41 (E) l - -- O K--___ / 3 �� P 33 0 ) (E) (E`)If p 1/----a_ (E) ,. �----------------------- (E) 102 (Di (E)O OPEN OFFICE 111 (E) - PA -61 = OFFICE (E) D (E) +36 +3s O L _�J I E) O (R) J (E) OFFICE �� r 1 ) 0 - - Q (E) 1 OFFIC 115 -- - -(1 ■ (E) 104 ---, (0 HR /, E�1H - (E) 112 ______1(E)....._ (E) (E) �11 Q - - ---- .(€)- - r � - - - ' (E) OFFICE 114 (E)t0 E)(Ev E () (E, l l� (E) (E) (E) E) �(E) C v (E) r r r r I>?>�.�1 e r »7>9> ii»».a C7�II r r r (E) 2 CHANNEL RACEWAY - ) 2 CHANNEL RAI9HI�:AY 116 r `�,� CA) ® ED) 2 FIRST FLOOR PLAN - POWER & SIGNAL 0 4' 8' 16' SCALE: 1/8"=1'-0" (G) EH) 3 4� GENERAL SHEET NOTES A. EXISTING POWER OUTLETS, COMMUNICATIONS AND EQUIPMENT MUST REMAIN UNLESS INDICATED AS DEMOLITION. REFER TO DRAWING ED2.1. B. CONFIRM EXISTING SPARE CAPACITY IN EXISTING PANELBOARDS PRIOR TO INSTALLING ANY WIRING DEVICES. C. EXISTING RECEPTACLE LOCATIONS ARE BASED ON EXISTING AS—BUILT DRAWINGS. CONTRACTOR TO CONFIRM EXISTING LOCATIONS. D. FOR ALL NEW DEVICES; MATCH COLOR AND FINISH OF EXISTING. E. FOR NEW ELECTRICAL CONNECTIONS SHOWN, PROVIDE CONNECTION TO EXISTING CIRCUITS AND RELATED CONDUCTORS AS SHOWN. PROVIDE THWN-2 CU CONDUCTORS WITH A MINIMUM SIZE OF #12 AWG ROUTED IN 3/4" EMT CONDUIT. MC CABLE IS ALSO AN APPROVED ALTERNATIVE. LOCATE ALL DEVICE OUTLETS IN MINIMUM 4—INCH SQUARE, 1-1/2" DEEP OUTLET WIRING BOXES. PROVIDE GALVANIZED STEEL OUTLET WIRING BOX, OF THE TYPE, SHAPE AND SIZE, INCLUDING DEPTH OF THE BOX TO SUIT EACH RESPECTIVE LOCATION AND INSTALLATION. F. PROVIDE CODE REQUIRED QUANTITY OF EXIT SIGNS PER CITY AND STATE LIGHTING CODES. CONNECT ANY NEW EXIT SIGNS TO EXISTING UNSWITCHED EXIT LIGHT CIRCUITS. 0 SHEET KEYNOTES 1 REMOVE AND RELOCATE AN (E) EXISTING LIGHTING FIXTURE TO A LOCATION AS INDICATED ON THE PLAN, TYPICAL OF 4. 2 PROVIDE A 'N' (NEW) LIGHTING FIXTURE; PARAMAX PARABOLIC TROFFER 2'X2' 277V AS INDICATED ON THE PLAN. THE NEW LIGHTING FIXTURE MODEL SHOULD BE EQUIVALENT TO LIGTHONIA 2PM3N OR AN APPROVED EQUAL. 3 PROVIDE POWER TO A NEW RECEPTACLE AS SHOWN BY CONNECTING TO AN EXISTING CIRCUIT NEARBY. 4 PROVIDE DEDICATED CIRCUIT TO NEW COPY/PRINTER CONNECT TO EXISTING CIRCUIT PA2-29. NEW 2 PORT TELECOM OUTLET WITH (2) CAT6 CABLES TO EXISTING TELECOM BACKBOARD/SWITCH AND 3/4" C. WITH PULLSTRING TO ACCESSIBLE CEILING SPACE. ROUTE (2) CAT -6 CABLES CONCEALED TO NEAREST TELECOM IDF/MDF ROOM. CONTRACTOR TO CONFIRM OWNER PREFERRED CONNECTION LOCATION PRIOR TO BID. 6 PROVIDE NEW DUAL TECHNOLOGY OCCUPANCY SENSOR AS SHOWN. WATTSTOPPER DT -300 SERIES OR APPROVED. PROVIDE POWER PACK AND OTHER EQUIPMENT AND CONNECTIONS NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM. 7 PROVIDE NEW IR OCCUPANCY SENSOR SWITCH; MATCH EXISTING TYPE, FINISH, AND CONTROL FUNCTION. 8 CONNECT SWITCH INTO EXISTING ROOM LIGHTING CONTROLS. 9 PROVIDE POWER AND CONTROL TO (R) RELOCATED LIGHTING BY CONNECTING TO AN EXISTING CIRCUIT NEARBY. 10 EXISTING SECURITY CAMERA TO BE REMOVED AND REINSTALLED IN SAME LOCATION AND DIRECTION. • ,AWHEAD ARCHITECTS PS. 1111 111 111 1.234.2;NORTt4T.PtAAY 'RELt.EVUE. rt x.$0113' (425.) .5564220 H¢ X (420;FCatr1:.22tt; SIGNATURE... SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED CITY OF TUKWILA JUN 102013 PERMIT CENTER PROJECT CONTACT 2013-0121 Michael Nelson INTERFACE ENGINEERING 1417 Fourth Avenue Suite 600 Seattle, WA 98101 TEL 206.382.0200 FAX 206.382.0202 www.interfaceengineering.com Includi9in Ith rfraxhEf rear duan Inowhoenor Ianipart, inI wfo mRaerval, OWNER... KING COUNTY HOUSING AUTHORITY 600 Andover Park West Tukwila, WA 98188 PHASE... Permit Set JOB NO... 12-09 DATE... 4113 t SHEET TITLE... First Floor Plan - t Electrical REVISIONS... SHEET NO... E2-1